Loading...
HomeMy WebLinkAboutPRE 2023-0056; 1734 HAVENS POINT PLACE; Admin Decision LetterNov.14,2023 Michael and Kari Leone 1734 Havens Point Place Carlsbad, CA 92008 -w1 a,~/ I I}, ~ /-z_ '3 7 ~ I LE CO PY ?'k.. , ~ SUBJECT: PRE 2023-0056 (DEV2023-0130)-1734 HAVENS POINT PLACE APN: 207-311-20-00 ("cicyof Carlsbad Thank you for submitting a preliminary review for an urban lot split project, pursuant to CA Senate Bill 9 (SB-9), commonly referred to as the Housing Opportunity & More Efficiency {HOME) Act, proposed at 1734 Havens Point Place, assessor's parcel number (APN) 207-311-20-00. The project site, an approximately 0.45-acre {19,600-square-foot) lot, currently is developed with a 1,931-square-foot single- family residence and an attached garage. The subject property is on a cul-de-sac with vehicular access provided off Havens Point Place. The project proposes a SB-9 urban lot split with a single-family dwelling on each of the proposed lots. More specifically, the preliminary review exhibit proposes: • To subdivide the existing parcel into two lots. • The existing single-family residence will remain on the first proposed lot. • A 1,500-square-foot residence will be constructed on the second proposed lot. In response to your application, the Planning Division has prepared this comment letter. Please note that the purpose of a preliminary review is to provide you with direction and comments on the overall concept of your project. This preliminary review does not represent an in-depth analysis of your project. It is intended to give you feedback on critical issues based upon the information provided in your submittal. This review is based upon the plans, policies, and standards in effect as of the date of this review. Please be aware that at the time of a formal application submittal, new plans, policies, and standards may be in effect and additional issues of concern may be raised through a more specific and detailed review. Planning: General 1. General Plan and zoning designations for the property are as follows: a. General Plan Land Use Designation: R-4, Residential (0-4 dwelling units per acre) b. Zoning: One-Family Residential (R-1). c. The property is in the Coastal Zone. The Coastal Zone land use designation and zoning are the same as the general plan and zoning above. 2. The project requires the following administrative permits, which are to be processed ministerially, without discretionary review or a hearing: Community Development Department Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008 I 442-339-2600 PRE 2023-0056 (DEV2023-0130) -11M~f'po1NT PLACE Nov.14,2023 Pa e 2 a. Minor Subdivision (MS) b. Minor Coastal Development Permit (CDP) 3. The proposed project is subject to CA Senate Bill 9 (SB-9), added Govt. Code §65852.21 and §66411.7: https://leginfo.legislature.ca.gov/faces/billNavClient.xhtml?bill id=202120220SB9 The requirements of SB-9 are summarized in the following information bulletin prepared by the City of Carlsbad: https://www.carlsbadca.gov/home/showpublisheddocument/8771/637774951657370000 4. The property is subject to the City's Local Coastal Program (LCP). As stated in the SB-9 Information Bulletin, referenced in bullet 3 above, properties subject to the LCP must comply with all certified development and zoning standards, density limitations, and permit process requirement for SB-9 developments in the Coastal Zone. Under the LCP, the subject property has an LCP Land Use designation of R-4 Residential, which allows a density of 0-4 dwelling units per acre (du/ac) consistent with the City's General Plan R-4 Land Use designation. Both the existing and proposed single-family residences are subject to density requirements. According to city information, the existing lot is 0.45 acres (ac), or 19,602 square-feet (sf) (0.45 ac x 43,560 sf= 19,602 sf). Proposing two dwelling units on 0.45 acres of land results in a residential density of 4.44 du/ac (2 units + 0.45 acres = 4.44 du/ac). A residential density of 4.44 du/ac exceeds the maximum unit yield allowed for the project site. As proposed, the project does not comply with the residential density requirements; and thus, is ineligible as a SB-9 project. 5. The remaining comments below are provided for information only. These comments would apply if the project were an eligible SB-9 lot split development in the R-1 Coastal Zone. 6. As stated in the SB-9 Information Bulletin, referenced in bullet 3 above, properties subject to the LCP must comply with all certified development and zoning standards, density limitations, and permit process requirement for SB-9 developments in the Coastal Zone. Pursuant to Govt. Code §65852.21 and §66411.7, a local agency may impose objective zoning standards, objective subdivision standards, and objective design review standards that do not conflict with the other requirements of SB-9. Pursuant to Sections 20.16.0lO(D) and 21.10.100 of the Carlsbad Municipal Code (CMC), the required minimum lot width is 60 feet. Based on the exhibit provided, there is not enough information to determine if the lot width of the proposed lot containing the existing residence will meet the minimum requirement. The lot width is the length of the arc comprising the front yard setback line. Please show the 20-foot front yard setback line with the arc dimensioned on the site plan. 7. As stated in the SB-9 Information Bulletin, no one parcel can be smaller than 40% of the original parcel size. The proposed 7,800-square-foot parcel is 39.8% of the original 19,602-square-foot parcel and does not meet the minimum requirement. PRE 2023-0056 (DEV2023-0130) -1734 HAVENS POINT PLACE Nov. 14, 2023 Page 3 8. On the site plan, please show building setbacks from the narrowest point between the property line and buildings. 9. The exhibit provided lists the existing single-family dwelling at 1,880-square-feet. The original building permit for the residence, permit 73-2372, lists a 1,931-square-foot single-family dwelling with a 482- square-foot garage. Please rectify this information on the formal application. 10. The proposed single-family residence shall demonstrate compliance with the development standards of the R-1 Zone in CMC 21.10 that do not directly conflict with SB-9. 11. New requirements related to the city's goals to reduce greenhouse gas (GHG) emissions will likely impact development requirements of this project. A formal application submittal will need to include a completed Climate Action Plan Checklist (Form P-30) to determine what requirements will apply to the project. New GHG reduction requirements are related to energy efficiency, photovoltaic, electric vehicle charging, water heating and traffic demand management requirements, as set forth in the California Green Building Standards Code and in Carlsbad Municipal Code Chapters 18.21, 18.30 and 18.51 which is available on the city's website at the following address: http://www.gcode.us/codes/carlsbad/view.php?topic=18&frames=on To the extent that new GHG reduction requirements are in effect at the time of application for grading or building permits, the project will be required to comply with the effective requirements even if different than what is proposed in the project's planning approvals. GHG reduction requirements may impact, but are not limited to, site design and local building code requirements. If incorporating new GHG reduction requirements results in substantial modifications to the project after planning approvals are obtained, then prior to issuance of grading or building permits, the applicant may be required to submit and receive approval of a Consistency Determination or an Amendment application for the project through the Planning Division. All necessary application forms, submittal requirements, and fee information are available at the Planning counter located in the Faraday Building at 1635 Faraday Avenue or online at https://www.carlsbadca.gov/departments/community-development/planning. You may also access the General Plan Land Use Element and the Zoning Ordinance online at the website address shown. Please review all information carefully before submitting. Land Development Engineering: 1. Please complete a Stormwater Standards Questionnaire Form E-34. This questionnaire will guide you and the city in determining what type of reports and storm water mitigation must be completed to satisfy state and City storm water quality requirements. The questionnaire is located on the City of Carlsbad website. 2. Please correctly plot the subdivision boundary, including all bearings, deltas, and distances, based on Map No. 7657. PRE 2023-0056 (DEV2023-0130)-1734 HAVENS POINT PLACE Nov.14,2023 Page 4 3. Please accurately plot the proposed parcel lines. Provide parcel areas based on record dimensions of Map No. 7657. This project is proposing a subdivision to create 2 parcels. A tentative parcel map is required. 4. Please provide a Preliminary Title Report (current within the last six (6) months). 5. Please annotate and delineate all existing easements and encumbrances listed in the Preliminary Title Report on the site plan. If any vacations or quitclaims are planned with this development, annotate on the site plan. 6. Per CMC15.16.060 this project may require a grading permit and grading plan. 7. Please provide a preliminary grading and drainage plan. 8. This project shall utilize City of Carlsbad Survey Control Network established on Record of Survey Map 17271, NAD83, Zone VI, 1991.35 Epoch for horizontal control and NGVD 29 datum for vertical control per City Engineering Standards Volume 1, Chapter 2. 9. Please delineate and annotate approximate topographic contours for existing and proposed condition. Provide 1-foot contours for slopes less than 5%; 2' intervals for slopes between 5% and 10%, and 5' intervals for slopes over 10%. Extend contours a minimum 20 feet beyond the project boundary. 10. On the preliminary grading and drainage plan, please show and identify all existing surface improvements screened back (curb, gutter, sidewalk, paving, manholes, inlets, streetlights, adjacent driveways, vaults, transformers, etc.) at the project site, project frontage and within 20 feet of the boundary. 11. Please remove the existing driveway and replace with an ADA compliant driveway per city engineering standards. 12. Please delineate all existing and proposed retaining walls that will be utilized on the project site and show top of wall and bottom of wall elevations, including at the highest and lowest points. 13. Please indicate the earthwork quantities (cut, fill, import, export, remedial) proposed for the project in cubic yards. 14. Please provide spot elevations at the corners of the existing and proposed buildings and at the corners of each parcel. Please include finish pad and floor elevations. 15. Please provide the method of draining each lot. 16. Cross lot drainage is not permitted. 17. Please delineate the location of all existing and proposed buildings, walls, fences, and permanent structures onsite and within 20 feet of the site. PRE 2023-0056 (DEV2023-0130)-1734 HAVENS POINT PLACE Nov. 14, 2023 Page 5 18. Please indicate on the site plan which trees are to remain or to be removed. 19. Please provide typical street cross sections for existing Havens Point Place. Please provide existing right-of-way width and existing improvements and proposed improvements. 20. Please delineate and annotate all proposed and existing driveways and driveway widths. 21. Please plot the turnaround for a 3-point turn of the AASHTO "P" passenger vehicle from the existing garage. 22. Please show all existing utilities and callout the size for: water, sewer, storm drain, and underground dry utilities in Havens Point Place. 23. Please plot existing and proposed water services, meters, backflows, and sewer laterals for the project in compliance with 2022 Carlsbad Engineering Design Standards requirements. 24. All transformers and electrical facilities solely serving this project site shall be located on site and outside of the public right-of-way. 25. Public potable water and sewer mains along project frontages must meet minimum design diameter and material as specified in City of Carlsbad Engineering Standard Vol. 2 Section 3.2.2 for water and Volume 1 Section 6.2 for sewer. Utility replacement and/or upsizing may be required as a condition of development. 26. Please provide multiple cross-sections of the site to demonstrate differences in grade from adjacent properties, existing and proposed grades on-site, fences and location of structures on-site and on adjacent properties. 27. A 3" AC grind and overlay may be required for/in Havens Point Place depending on the number of utility trenches required for the project. 28. Please address the comments on the attached red lined plan. 29. Please be advised that a more in-depth review of the proposed development will occur with the permit application when a more complete design of the project is provided. Building Division: 1. No comments. Fire Department: 1. No Fire Department concerns with the lot split. If you would like to schedule a meeting to discuss this letter with the commenting departments, please contact Edward Valenzuela at the number below. You may also contact each department individually as follows: PRE 2023-0056 (DEV2023-0130) -1734 HAVENS POINT PLACE Nov.14,2023 Page 6 • Planning Division: Edward Valenzuela, Associate Planner, at (442) 339-2624 • Land Development Engineering: Tim Carroll, Project Engineer, at (442) 339-2737 • Fire Department: Randy Metz, Fire Inspections, at (442) 339-2661 • Building Division: Mike Strong, Assistant Director of Community Development, at (442) 339-2721 Sincerely, ERIC LARDY, AICP City Planner EL:EV:mh c: Michael and Kari Leone, 1734 Havens Point Place, Carlsbad, CA 92008 Fire Prevention Laserfiche/File Copy Data Entry Enclosures: Land Development Engineering Division: 1. Redlined Plans . . . c.o~ 7°<....--"--( ?Li:>• ----~ Cu 1,--0.f:::-$.AC. +fu:,+ ~7-\-0:) ;~KA&c ~~J.- r-Jeu./ . . _v~t.:.b . CITY OF CARLSBAD. ' OCT J 2023 PLANNING DIVISION