HomeMy WebLinkAbout1808 ASTON AVE; 170; AS140138; Permit9/14/22, 3:39 PM AS140138 Permit Data City of Carlsbad Sprinkler Permit Job Address: 1808 ASTON AV Permit Type: SPRINK Parcel No: 2121200700 Lot #: 0 Reference No.: Permit No: AS140138 Status: ISSUED Applied 6/10/2014 Approved: 6/19/2014 Issued: 6/19/2014 PC #: Inspector: Project Title: VERTICAL SEARCH WORKS ADD! RECLOCATE 17 NEW SPRINKLERS FOR TI IN EXISTING OFFICE BLDG. THE EXISTING FIRE SPRINKLER COVERAGE OUTSIDE THE AREA OF WORK WILL REMAIN AND WILL NOT BE AFFECTED BY THE SCOPE OF WORK. Applicant: SCHMIDT FIRE PROTECTION CO INC 4760 MURPHY CANYON RD SAN DIEGO, CA 92123 858-279-6122 Owner: MC RASTON L LC 1808 ASTON AVE #180 CARLSBAD CA Fees ($)JAddhIFees($r Total ($) Balance ($) 268 0 268 0 about:blank 1/1 AS140138 Fire Protection Contacts www.tyco-fire.com - Products i.kièia?.1;!- trk I7rmi General Description The Series EC-8 Extended Cover- age Pendent Sprinklers are decora- tive glass bulb sprinklers designed for use in light hazard occupancies. They are intended for use in automatic sprinkler systems designed in accor- dance with standard installation rules (e.g., NFPA 13) for a maximum cover- age area of 400 ft2 (37,2 m2), as com- pared to the maximum coverage area of 225 ft2 (20,6 m2) for standard cov- erage sprinklers used in light hazard occupancies. The recessed version of the EC-8, in- tended for use in areas with a finished ceiling, uses either the two-piece Style 30 or 40 Recessed Escutcheon. The Style 30 Recessed Escutcheon provides up to 1/2 inch (12,7 mm) of total adjustment from the flush pen- dent position, whereas, the Style 40 provides 3/4 inch (19,1 mm) of verti- cal adjustment from the flush pendent position. The adjustment provided by the Recessed Escutcheons reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- tained when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the ap- plicable approval agencies, the test- ing is not representative of all possible IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cau- tions with respect to handling and installation of sprinkler sys- tems and components. Improp- er handling and installation can permanently damage a sprin- kler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 6 corrosive atmospheres. Consequent- ly, it is recommended that the end user be consulted with respect to the suitability of these corrosion resistant coatings for any given corrosive envi- ronment. The effects of ambient tem- perature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. NO TICE. The Series EC-8 Extended Coverage Sprinklers described herein must be installed and maintained in compli- ance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any oth- er authorities having jurisdiction. Fail- ure to do so may impair the perfor- mance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number TY4232 - Pendent, 8.0K TY4232 is a re-designation for C4232 Technical Data Approvals UL and C-UL Listed. FM and NYC Ap- proved. (Refer to Table A for complete approval information including corro- sion resistant status. The approvals apply to the service conditions indi- cated in the Design Criteria section.) Maximum Working Pressure 175 psi (12,1 bar) MARCH 2014 Pipe Thread Connection 3/4 inch NPT Discharge Coefficients K=8.0 GPM/psi112 (115,2 LPM/barl/2) Temperature Ratings 135°F (57°C) and 155°F (68°C) Finish Sprinkler: Refer to Table A Recessed Escutcheon: Natural Brass, Signal White, and Chrome Plated Physical Characteristics Frame ............................Bronze Button .......... ..... . ........... .Bronze Sealing Assembly ........Beryllium Nickel wl TEFLON Bulb .....................Glass (3 mm dia.) Compression Screw ................Bronze Deflector ....... .................... Brass TFP223 Upright Pendent Vertical Sidewall Conventional Horizontal Sidewall Recessed Pendent/F1/F2 Recessed Horizontal Sidewall Pendent/FP Application Quick response sprinklers are used in fixed fire protec- tion systems: Wet, Dry, Deluge or Preaction. Care must be exercised that the orifice size, temperature rating, deflec- tor style and sprinkler type are in accordance with the lat- est published standards of the National Fire Protection As- sociation or the approving Authority Having Jurisdiction, Quick response sprinklers are intended for installation as specified in NEPA 13. Quick response sprinklers and stan- dard response sprinklers should not be intermixed. AS140138 I Bulletin 014 Rev. F Model Fl FR56 Series Quick Response Standard Spray CC) C CD 0 CD m Model Fl FR56 Sprinkler Types Standard Upright Standard Pendent Conventional Vertical Sidewall Horizontal Sidewall Model Fl FR56 Recessed Sprinkler Types Standard PendentJF1/F2/FP Horizontal Sidewall Model Fl FR56 Concealed Sprinkler Types Standard Pendent Listing & Approvals Underwriters Laboratories Inc. and Certified for Canada (cULus). Factory Mutual Approvals (FM) Loss Prevention Council (LPCB, UK) VdS SchadenverhUtung GmbH UL Listing Category Sprinklers, Automatic & Open (VNIV) Quick Response Sprinkler Product Description Reliable Models F1FR56 Series Sprinklers are quick re- sponse sprinklers which combine the durability of a stan- dard sprinkler with the attractive low profile of a decorative sprinkler. The Models F1FR56 Series Recessed automatic sprin- klers utilize a 3.0 mm frangible glass bulb. These sprin- klers have demonstrated response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model F1FR56 Series sprinklers to apply water to a fire much faster than standard sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely manu- factured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as the liq- uid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 13-222 INSTALLATION OF SPRINKLER SYSTEMS Contractor's Material and Test Certificate for Aboveground Piping PROCEDURE Upon completion of work, inspection and tests shat be made by the contractor's representative and witnessed by the property owner or their authorized agent. All defects shall be corrected and system left in service before contractor's personnel finally leave the job. A certificate shall be filled out and signed by both representatives. Copies shall be prepared for approving authorities, owners, and contractor. It is understood the owner's representative's signature in no way prejudices any claim against contractor for faulty material, poor workmanship, or failure to comply with approving authority's requirements or local ordinances. Property name rc...k Date -., - Property address Acceapproviautties (n Address Plans Installation conforms to accepted plans 'ies UNo Equipment used is approved t No If no, explain deviations Has person in chaise of fire equipment been instructed as <s EJ No to location of control valves and care and maintenance of this new equipment? If no, explain Instructions Have copies of the following been left on the premises? l Yes System components instructions (3 ) %$}7,.,U4'r3c 0 IJ Yes J No Care and maintenance instructions , LJ Yes j No NFPA 25 I [Dyes; tNo Location of sys tern h Supplies buildings Year of Orifice ' Temperature Make Model manufacture size Quantity rating I~ALc1 %(I-(. 2.O3 IL Sprinklers :L~f Ca ,710 Pipe and Type of pipe 49 t_o b (ioc., n t. Type of fittings 64Ak... to fittings Alarm Maximum time to operate valve or Alarm device through test connection flow Type Make Model Minutes Seconds indicator Dry valve 0.0. D. iak ç' Model Serial no. Make Model Serial no. firn to kip Time water Alarm Dry pipe operating - through test connectiona.b Water pressure Air pressure Trip point air pressure reached test outleta,b operated properly test Minutes Seconds psi psi psi Minutes Seconds Yes I No Without Q.O.D. With O.O.D. If no, explain © 2006 National Fire Protection Association NFPA 13 (p. 1 of 3) ivieasurea irom time inspectors test connection is opened b NFPA 13 only requires the 60-second limitation in specific sections FIGURE 24.1 Contractor's Material and Test Certificate for Aboveground Piping. 2007 Edition SYSTEMS ACCEPTANCE 13-223 Operation LiPneumatic LiElectric Li Hydraulics Piping super .1 IVA Li Yes LiNo Detecting media supervised LiYes UNo Does valve oeraterom the manual trip, remote, or both Li Yes UNo control stations? Deluge and Is there an accessible facility in each circuit If no, explain pre-action for testing? valves Ij Yes No Does each circuit operate Does each circuit operate Maximum time to Make Model supervision loss alarm? valve release? operate release Yes No Yes No Minutes Seconds Location Makeand Residual pressure Pressure and floor j 1m0 Setting Static pressure (flowing) Flow rate reducing Inlet (psi) Outlet (psi) Inlet (psi) Outlet (psi) Flow (gpm) valve test w n Hydrostatic: Hydrostatic tests shall be made at not less than 200 psi (13.6 bar) for 2 hour s o r 5 0 p s i ( 3 . 4 b a r ) above static pressure in excess of 150 psi (102 bar) for 2 hours. Differential dry-pipe valve cla p p e r s s h a l l b e l e f t open during the test to prevent damage. All aboveground piping leakage shall be stopped. Test description Pneumatic: Establish 40 psi (2.7 bar) air pressure and measure drop, which shell n o t e x c e e d 1 ½ p s i ( 0 . 1 b a r ) in 24 hours. Test pressure tanks at normal water level and air pressure and measure a i r p r e s s u r e d r o p , w h i c h s h a l l not exceed 11h psi (0.1 bar) in 24 hours. All piping hydrostatically tested at _psi (—bar) for - hours If no, state reason I Dry piping pneumatically tested U Yes ( No k 1 I Equipment operates properly Yes U No Do you certify as the sprinkler contractor that additives and corrosive chemicals, sodium silicat e o r d e r i v a t i v e s of sodium silicate, brine, or other corrosive chemicals were not used for testing systems or st o p p i n g l e a k s ? Lives [:]No Drain Reading of gauge located near water Residual pressure with valve in test Tests test supply test connection: psi (........... bar) connection open wide: psi (....._bar) Underground mains and lead-in connections to system risers flushed before connection m a d e t o sprinkler piping Verified by copy of the Contractors Material and Test Li Yes Li No Other Explain Certificate for Underground Piping. Flushed by installer of underground sprinkler piping Li Yes Li No If powder-driven fasteners are used in concrete, Li Yes Li No If no, explain has representative sample testing been satisfactorily completed? Blank testing Number used Locations Number removed gaskets Welding piping Li Yes f If yes... Do you certify as the sprinkler contractor that welding procedures used complied with Li Yes the minimum requirements of AWS B2.1, ASME Section IX Welding and Brazing Qualifications, or other applicable qualification standard as required by the AHJ? Do you certify that all welding was performed by welders or welding operators Li Yes Li No qualified in accordance with the minimum requirements of AWS B2.1, ASME Section IX Welding and Brazing Qualifications, or other applicable qualification standard as Welding required by the AHJ? Do you certify that the welding was conducted in compliance with a documented Lives LiNO quality control procedure to ensure that (1) all discs are retrieved; (2) that openings in piping are smooth, that slag and other welding residue are removed; (3) the internal diameters of piping are not penetrated; (4) completed welds are free from cracks, incomplete fusion, surface porosity greater than 'As in. diameter, undercut deeper than the lesser of 25% of the wall thickness or 1/ in.; and (5) completed circumferential butt weld reinforcement does not exceed in.? © 2006 National Fire Protection Association NFPA 13 (p. 2 of 3) FIGURE 24.1 Continued 2007 Edition INSTALLATION OF SPRINKLER SYSTEMS FIGURE 24.1 Continued 2007 Edition