Loading...
HomeMy WebLinkAbout1808 ASTON AVE; 220 | 230 | 235; FPC2019-0175; PermitER]tT REPORT Print Date: 09/14/2022 Permit No: FPC2019-0175 Job Address: 1808 ASTON AVE. # 220/230/235, CARlSBAD, CA 92008-7365 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel 4*: 2121200700 Track 4*: Applied: 07/31/2019 Valuation: $0.00 Lot 4*: Issued: 08/06/2019 Occupancy Group: Project 4*: Finaled Close Out: 10/25/2019 #of Dwelling Units: Plan 4*: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check 4*: INSPECTOR: Salcedo, Felix Plan Check 4*: Project Title: Description: SPEC SUITES 220, 230, 235 -SPRINKLER TI (64 HEADS) Applicant: FPContractor: SCHMIDT FIRE PROTECTION CO INC SCHMIDT FIRE PROTECTION CO INC JASON ALVA 4760 MURPHY CANYON RD 4760 MURPHY CANYON RD SAN DIEGO, CA 92123-4321 SAN DIEGO, CA 92123-4321 (858) 279-6122 (858) 279-6122 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $553.00 Total Fees: $553.00 Total Payments To Date: $553.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad-CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov RC2-01 c1_. Ol'uIIetIn 014 Rev. P R I a R 0 b l Model Fl FR Series Quick Response Glass Bulb Sprinklers Model Fl FR56 Sprinkler Types Standard Spray Upright Standard Spray Pendent Conventional Upright/Pendent Vertical Sidewall Horizontal Sidewall Model Fl FR56 Recessed Sprinkler Types Standard Spray Pendent Horizontal Sidewall Model Fl FR56 Concealed Sprinkler Types Standard Spray Pendent Model Fl FR42, Fl FRXLH & Fl FR28 Sprinkler Types Standard Spray Upright Standard Spray Pendent Model Fl FR40 Sprinkler Types Standard Spray Pendent Model Fl FR42, Fl FR40, Fl FRXLH & Fl FR28 Recessed Sprinkler Types Standard Spray Pendent Model Fl FR56LL & Fl FR42LL Low Lead Sprinkler Types Standard Spray Pendent with less than 0.25% Lead Content Listing & Approvals The following organizations provide Listings or Approvals for various Model F1FR series sprinklers. See the Design and Installation table in this Bulletin for information on specific listings and approvals applicable to each sprin- kler. Underwriters Laboratories Inc. and Certified for Canada (cULus) in accordance with ANSI/UL199. FM Approvals (FM) Loss Prevention Certification Board (LPCB) VdS Schadenverhutung GmbH (VdS) Underwriters Laboratories Inc. and Underwriters Laboratories of Canada Certified for Health Effects to NSF/ANSI Standard 61 Annex G (ULH) EC Certificate: 0786-CPD-40239 (RA1414), 0786- CPD-4025 1 (RA1 425), 0786-CPD-40252 (RA1 475) (EC) UL Listing Category Sprinklers, Automatic & Open (VNIV) Quick Response Sprinkler Upright Pendent Conventional Vertical Sidewall Horizontal Sidewall Recessed Pendent/Fl/F2 Recessed Concealed Recessed Horizontal Sidewall Pendent Pendent/FP XLH Upright XLH Pendent XLH Recessed Pendent F1/F2 Product Description Reliable Model F1FR series sprinklers are quick-response automatic sprin- klers with a glass bulb thermal element. Model F1FR series sprinklers are Stan- dard Spray sprinklers, with the excep- tion of the Model Fl FR56 Conventional XLH Recessed sprinkler which is an Old-style/Conven- Pendent FP tional sprinkler. The Model F1FR Series automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrat- ed response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model El FR Series sprinklers to apply water to a fire faster than standard-response sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely man- ufactured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as the liq- uid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. Model Fl FR Series sprinklers provide a wide range of op- tions where quick-response, glass bulb sprinklers are used: Pendent, recessed pendent, upright, horizontal sidewall, and vertical sidewall deflectors K-factors of 2.8 (40 metric), 4.0 (57 metric), 4.2 (60 metric), and 5.6 (80 metric) Flush, recessed, and concealed installations See the Design and Installation Information table in this Bulletin for information on the approvals and availability of specific Model Fl FR series sprinkler configurations. Model F1FR Recessed Pendent ard Recessed Horizon- tal Sidewall sprinklers are required tobe used with Reliable Model Fl, F2, or FP recessed escutcheons. See the Re- cessed Escutcheon Data table in this Bulletin for listing and approval information with each specific Model El FR series sprinkler. Model Fl and F2 recessed escutcheons, shown in Fig. 1 and 3, are a friction fit assembly allowing for 3/4-inch (19mm) and 1/2-inch (12.7mm) of adjustment, respectively. Model FP recessed escutcheons, shown in Fig. 2, provide a 1/2-inch (12.7mm) threaded adjustment. Model Fl FR56 Concealed Pendent and Model Fl FR56LL Concealed Pendent sprinklers are required to be used with Model CCP cover plates. A standard profile Model CCP cov- er plate is available that provides up to 1/2-inch (12.7mm) of cover plate adjustment. In addition, a low profile Model CCP cover plate is also available that provides up to 5/16-inch (8.0mm) of cover plate adjustment. See the Design and In- stallation Information and Listed and Approved Temperature Ratings tables in this Bulletin for further information on ap- proved cover plate options. Application Model F1FR Series sprinklers are intended for use in accordance with NFPA 13, FM Property Loss Prevention Data Sheets, and the requirements of the Authority Hav- ing Jurisdiction. Care must be exercised that the k-factor, temperature rating, deflector style, and sprinkler type are in accordance with the requirements of the applicable design and installation standards. In addition, Model El FR Series sprinklers must be used in accordance with their listings and approvals, as well as the information provided in this Bulletin. Installation Glass bulb sprinklers have orange bulb protectors or pro- tective caps to minimize bulb damage during shipping, han- dling and installation. Reliable sprinkler installation wrench- es are designed to install sprinklers with bulb protectors in place. Remove the bulb protector at the time when the sprin- kler system is placed in service for fire protection. Removal of the bulb protector before this time may leave the bulb vul- nerable to damage. Remove bulb protectors by undoing the clasp by hand. Do not use tools to remove bulb protectors. Model F1FR Series sprinklers must be installed with the Reliable sprinkler installation wrench identified in the Design and Installation Information table in this Bulletin. Any other wrench may damage the sprinkler. A leak tight sprinkler joint can be obtained with a torque of 8 to 18 lb-ft (11 to 24 N-m). Do not tighten sprinklers over the maximum recommended installation torque. Exceeding the maximum recommended installation torque may cause leakage or impairment of the sprinkler. Recessed Sprinklers Model F1FR Series Recessed sprinklers are to be installed as shown in Fig. 1, Fig. 2, or Fig. 3, as applicable to the spe- cific model being installed. The Recessed Escutcheon Data table in the Bulletin identifies the only recessed escutcheons that are permitted to be used with each Model El FR Series Recessed sprinkler. The use of any other recessed escutch- eon will void all approvals and negate all warranties. Concealed Sprinklers Model El FR Series Concealed Pendent sprinklers are to be installed as shown in Fig. 4 or Fig. 5, as applicable to the selected cover plate. Model F1FR56 Concealed Pendent and Model Fl ER56LL Concealed Pendent sprinklers have a factory-installed Model CCP cup. A protective cap is in- stalled at the factory that should remain on the sprinkler until the sprinkler is installed and should then be reinstalled on the sprinkler until the cover plate is installed. The concealed sprinkler assemblies are completed by the installation of a Model CCP push-on/thread-off cover plate assembly. The cover plate and sprinkler cup assemblies are joined using a cover plate skirt with flexible tabs for threaded engage- ment. A choice of two Model CCP cover plate assemblies provides either 1/2-inch (13mm) or 5/8-inch (8mm) of cover adjustment. Do not install Model F1FR Series Concealed Pendent sprinklers in ceilings which have positive pressure in the space above. Model F1FR Series Concealed Pendent sprinklers require a 2-5/8-inch (67mm) diameter hole to be cut in the ceiling. The Model RC1 wrench is used to engage the sprinkler wrenching surfaces and to install the sprinkler in the fitting. Remove the protective cap to install the sprinkler, then reinstall the protective cap until the cover plate is installed. When inserting or remov- ing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. Do not wrench any other part of the sprinkler/cup assembly. Installation is com- pleted by removing the protective cap from the sprinkler and pushing the cover plate onto the cup. Final adjustment is made by hand turning the cover plate until the skirt flange makes full contact with the ceiling. Cover plate removal requires turning the cover plate in the counter clockwise direction. After installation, inspect all sprinklers to ensure that there is a gap between the cover plate and ceiling and that the four cup slots are open and free from any air flow impediment to the space above. Concealed cover plate/cup assemblies are listed only for use with specific sprinklers. The use of any concealed cover plate/cup assembly other than the Reliable Model CCP with Model El FR56 Concealed Pendent and Model El FR56LL Concealed Pendent sprinklers or the use of the Model CCP Concealed cover plate assembly on any sprinkler with which it is not specifically listed my prevent good fire pro- tection and will void all guarantees, warranties, listings and approvals. Technical Data: Sensitivity: Quick-response Thread Size: 1/2-inch NPT standard; ISO 7-R1/2 optional Maximum Working Pressure: 175 psi (12 bar) - 100% Factory tested hydrostatically to 500 psi (34.5 bar) SIN RA1425, RA1414 & RA1435 cULus listed for 250 psi (17 bar) Design and Installation Information Model Nominal K-factor Nominal Orifice Diameter Deflector! Orientation Nominal Sprinkler Height ____ Installation Wrench SIN Approvals Listings and Approval Notes US Metric inches mm inches mm Pendent 2.25 57 DorW2 RA1411 cULus 2 Recessed Pendent 2.25 57 GFR2 RA1411 cULus 2 F1FR28 2.8 40 3/8 10 Upright 2.25 57 DorW2 RA1421 cULus 1,2 F1FR40 4.0 57 3/8 10 Pendent 2.25 57 DorW2 RA1418 VdS Recessed Pendent 2.25 57 GFR2 RA1418 VdS Pendent 2.25 57 D or W2 RA1413 cULus 2 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 F1FR42 4.2 60 7/16 10 Upright 2.25 57 DorW2 RA1423 cULus 1,2 F1FR42LL 4.2 60 7/16 10 Pendent 2.25 57 DorW2 RA1410 cULus, ULH ___ Recessed Pendent 2.25 57 GFR2 RA1410 cULus, ULH F1FRXLH Pendent 2.25 57 DorW2 RA1413 cULus 2 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 (F1FR42 4.2 60 7/16 10 with Pintle) Upright 2.25 57 DorW2 RA1423 cULus 1,2 Pendent 2.25 57 DorW2 RA1414 cULus, FM, LPCB, VdS, EC 1,2,3,4 Recessed Pendent 2.25 57 GFR2 RA1414 cULus, FM, LPCB, VdS, EC 1,2,3,4 Concealed Pendent 2.25 57 RC1 RA1414 cULus,VdS,EC 5,6 F1FR56 5.6 80 1/2 15 Upright 2.25 57 D or W2 RA1425 cULus, FM, LPCB, vds, EC 1,2,3,4 "Conventional Fendent or Upright)" 2.25 57 D or W2 RA1475 LPCB, VdS, EC 4 Pendent 2.25 57 DorW2 RA1415 cULus, ULH 1 Recessed Pendent 2.25 57 GFR2 RA1415 cULus, ULH F1FR56LL 5.6 80 1/2 15 Concealed Pendent 2.25 57 RC1 RA1415 cULus, ULH 6 Horizontal Sidewall 2.63 67 D or W2 RA1435 cULus, FM 1,2,3,7 Recessed Horizontal 2.63 67 Sidewall GFR2 RA1435 cULus, FM 8 F1FR56 5.6 80 1/2 15 F1FR56 5.6 80 1/2 15 Vertical Sidewall (Pendent or Upright) 2.25 57 DorW2 RA1485 cULus, FM, LPCB 1,2,3,9 cULus Listed corrosion Resistant sprinkler when ordered with available Polyester coating. cULus Listed corrosion Resistant sprinkler when ordered with available Electroless Nickel PTFE plating. Available with FM approved Polyester coating in black or white. Available with LPCB and VdS approved Polyester coating. VdS and EC approvals of the F1FR56 Concealed Pendent sprinkler are for 155°F (68°C) temperature rated sprinklers only. VdS approved sprin- klers must use Norbulb brand glass bulbs with the 1/2-inch (12.7mm) adjustment Model CCP cover plate only. Model F1FR56 Concealed Pendent and Model F1FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates, available as either standard depth with 1/2-inch (12.7mm) of adjustment or low profile with 5/16-inch (8.0 mm) of adjustment. cULus Listing of the Fl FR56 Horizontal Sidewall sprinkler is for Light and Ordinary Hazard occupancies only. Minimum to maximum deflector to ceiling distance shall be 4 inches to 12 inches (102mm to 305mm). FM Approval of the F1FR56 Horizontal Sidewall sprinkler is for Light Hazard occupancies only. cULus Listing and FM Approval of the Fl FR56 Recessed Horizontal Sidewall sprinkler is for Light Hazard occupancies only. The F1FR56 Vertical Sidewall sprinkler is listed and approved for use only in Light Hazard occupancies. LPCB approval of the F1FR56 Vertical Sidewall sprinkler is for installation in the Pendent position only. 3. Listed and Approved Temperature Ratings Model Deflector/ Orientation Ordinary Temp. Classification 100°F (38°C) Max. Ambient Temp. Intermediate Temp. Classification 150°F (65°C) Max. Ambient Temp. High Temp. Classification 225°F (1 07°C) Max. Ambient Temp. 135°F (57°C) Temp. Rating I 155°F (68°C) I Temp. Rating 175°F (79°C) Temp. Rating I 200°F (93°C) Temp. Rating 286°F (141°C) Temp. Rating Orange Bulb Red Bulb I Yellow Bulb i Green Bulb Blue Bulb Pendent cULus F1FR28 Recessed Pendent cULus I -- __________ Upright cULus Pendent VdS F1FR4O Recessed Pendent VdS I -- Pendent cULus F1FR42 Recessed Pendent cULus I -- __________ Upright cULus Pendent -- I cULus, ULH I -- I Fl FR42LL Recessed Pendent -- I I cULus, ULH I Pendent cULus F1FRXLH Recessed Pendent cULus I -- __________ Upright cULus Pendent cULus, FM, LPCB, VdS, EC Recessed Pendent cULus, FM, LPCB, VdS, EC -- I F1FR56 Concealed Pendent* cULus I cULus,VdS,EC I cULus I -- Upright cULus, FM, LPCB, VdS, EC "Conventional (Pendent or Upright)" LPCB, VdS, EC Pendent -- I cULus, ULH I -- F1FR56LL Recessed Pendent -- I cULus, ULH I -- _________ Concealed Pendent* I cULus, ULH I -- Horizontal Sidewall cULus, FM Fl FR56 Recessed Horizontal Sidewall cULus, FM I - F1FRS6 Vertical Sidewall (Pen- dent _or_Upright) cULus, FM, LPCB * Model El FR56 Concealed Pendent and Fl FR56LL Concealed Pendent sprinklers must be used with Reliable Model COP cover plates. For Ordinary Temperature Classification sprinklers use a 1350F (57°C) temperature rated cover plate. For Intermediate Temperature Classification sprinklers use a 165°F (740C) temperature rated cover plate. Recessed Escutcheon Data Listed and Approved Recessed Escutcheons Model Fl Model F2 Model FP Model Deflector/ (Fig. 1 & 3) (Fig. 1 & 3) (Fig. 2) SIN Orientation 3/4-inch (19mm) 1/2-inch (12.7mm) 1/2-inch (12.7mm) adjustment adjustment adjustment F1FR28 Recessed Pendent cULus cULus cULus RA1411 F1FR40 Recessed Pendent VdS VdS VdS RA1418 FIFR42 Recessed Pendent cULus cULus cULus RA1413 F1FR42LL Recessed Pendent cULus, ULH cULus, ULH cULus, ULH RA1410 F1FR42XLH Recessed Pendent cULus cULus cULus RA1413 F1FR56 Recessed Pendent cULus, LPCB, VdS, cULus, FM, LPCB, cULus, VdS, EC RA1414 EC VdS, EC F1FR56LL Recessed Pendent cULus, ULH cULus, ULH cULus, ULH RA1415 F1FR56 Recessed Horizontal Sidewall cULus cULus, FM cULus RA1435 4. TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER WRENCH BOSS -\ Fl ESCUTCHEONJ_ E117 Z7 3/4"[l9mm] ADJUSTMENT F2 ESCUTCHEON 1/2'T12.7mm] ADJUSTMENT 2 1/4" HOLE OH. [57.2mm] 1 15/76" 0/A [49.2mm] T F1 \ I (1 X 7/2" REDUCER FACE OF FITTING TO FACE OF CEILING DIMENSION Fl ESCUTCHEON AT MAX/MUM RECESS = 1 "[25.4mm] AT MINIMUM RECESS = 3/8"[9.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS = ,3/4"[l9mm] -7-7-7-7-7-77 I AT MINIMUM RECESS = 3/8"[9.5mm] Fl ESCUTCHEON AT MAX/MUM RECESS = 7/8"[22.2mm] [3.2mm] I / AT MINIMUM RECESS = 7-5/8 "[41.3mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 1-1/8'128.6mm] AT MINIMUM RECESS = 1-5/8 "[4 7.3mm] 2 27/32" 0/A. [72.2mm] Model El FR56, El ER56LL, El FR42, El FR40, Fl FR42LL, El FRXLH & El FR28 Recessed Pendent sprinkler with Model El or F2 escutcheon 1" X 1/2" REDUCER 2 5/8" 0/A. [66.7mm] HOLE IN CEILING 2 5/16" 0/A. [58.7mm] CUP CEILING FACE OF FITTING TO FACE OF CEILING DIMENSION AT MAXIMUM RECESS = 1- 1/2"[38mm] AT MINIMUM RECESS = 1 "[25.4mm] AT MAXIMUM RECESS = 9/16"[14.jmm] Y2 "[12.7mm] AT MINIMUM RECESS = 1 "[25.4mm] ADJUSTMENT Model El FR56, El FR56LL, Fl FR42, El FR40, Fl FR42LL, El FRXLH & El FR28 Recessed Pendent sprinkler with Model FP escutcheon 5. Fl ESCUTCHEON AT AlA VIAl//Al P( - 1_ /P "T2 o,.,,,.,.,7 - AT MINIMUM RECESS = 2-1/16 "[52.4mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 1-5/8"[41.3mm] 1/8" AT MINIMUM RECESS = 2— l/16"[52.4mm] Ii .2mm] Y (1) 4"-12" [101. 6mm-304.8mm] 32 DIA CEILING TO ; L . [72.2mm] DEFLECTOR -I i Fl ESCUTCHEON 3/4"[19mm] ADJUSTMENT F2 ESCUTCHEON 1/2"[12. 7mm] ADJUSTMENT FACE OF FITTING TO FACE OF CEILING DIMENSION Fl ESCUTCHEON AT MAXIMUM RECESS = 1 "[25.4mm] AT MINIMUM RECESS = 3/8"[9.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 3/4"[19mm] AT MINIMUM RECESS = 3/8"[9.5mm] 2 1/4" HOLE DIA. [5 7.2mm] 1" X 1/2" REDUCER I I 1 15/16" DIA [49.2mm] I - TURN COLLAR UNTIL -' TIGHT AGAINST SPRINKLER WRENCH BOSS. RECESSED HSW w/F1 OR F2 ESCUTCHEON (1) FM APPROVED FOR 4" - 6" [10 1.6MM - 152.4MM] CEILING TO DEFLECTOR WITH F2 ONLY. Fig.3 Model El FR56 Recessed Horizontal Sidewall sprinkler with Model El or F2 escutcheon 1" x 1/2" REDUCING TEE OR ELBOW + 2 5/B" CIA. 2 5/16" CIA - HOLE IN CEILING CUP CEILING -' 1/2" MAX. 5 COVER ADJUSTMENT COVER PLATE ASSEMBLY 5/16" CIA SPRINKLER 1 1/2" MAX. FACE OF FITTING ~77 -;J TO FACE OF CEILING DIMENSION CONCEALED, 1/2" ADJUSTMENT 017FGO1A Fig.4 Model Fl FR56/F1 FR56LL Concealed Pendent sprinkler with standard depth 1/2-inch (12.7mm) adjustment - Model CCP cover plate 1" x 1/2" REDUCING TEE OR ELBOW —EH-- 2 5/16" 0/A - CUP j~_ CEILING 5/16" MAX. COVER ADJUSTMENT COVER PLATE ASSEMBLY SPRINKLER 2 5/8" 0/A. HOLE I/V CEILING 1 1/2" MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION 314 3 5/16" 0/A. CONCEALED, 5/16" ADJUSTMENT 017FG02A Fig. 5- Model El FR56/F1 FR56LL Concealed Pendent sprinkler with low profile 5/16-inch (8.0mm) adjustment - Model CCP cover plate Maintenance The Model El FR Series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Replace any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow .quick replacement of damaged or operated sprinklers. Finishes (1) Standard Finishes Sprinkler Escutcheon I Cover plate111 Bronze Brass Chrome Chrome Plated Chrome Plated White Polyester Coated (X) White Painted I Special Application Finish"' Sprinkler Escutcheon Cover plate0t Electroless Nickel PTFE(7)PTFE Electroless Nickel Bright rig Brass Bright Brass 31 Bright Brass Black Plating Black Plated Black Plated Black Paint Black Paint 21161 Black Paint Off White Off White (2)(6) Off White Satin Chrome Chrome Dull Chrome Dull Other finishes and colors are available on special order. Consult the factory for details. Custom color painted sprinklers may not retain their UL Corrosion resistance listing. Coverplate custom paint is semi-gloss, unless specified otherwise. cULus Listed only. 200°F (93°C) maximum. cULus listed "corrosion resistance" applies to SIN Numbers RA1435 (HSW), RA1485(VSW), RA1425 (Upright), RA1414 (Pendent) and RA1415 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. FM Approvals finish as "Polyester coated" applies to SIN Number RA1414, RA1435 and RA1425 in standard black or white. LPCB and VdS Approved finish applies only to RA1425, RA1414, RA1418 (VdS) and RA1475. cULus listed Corrosion Resistant Material Data Frame: DZR Brass, QM Brass, or Low Lead Brass Deflector: CDA Alloy 220, 260, or 510 Load Screw\Pintte: CDA Alloy 360 or 544 Cup: CDA Alloy 651 or 693 Washer Nickel Alloy 440 or 360, coated with PTFE Adhesive Tape Bulb: Glass Ordering Information Specify: Sprinkler Model: [El ER28] [El ER40] [Fl FR421 [El FR42LL][Fl FRXLH][E1 ER56][E1 ER56LL] Sprinkler Deflector/Orientation: [Pendent][Recessed Pendent] [Upright] [Conventional] [Horizontal Sidewall] [Recessed Horizontal Sidewall] [Vertical Sidewall] Sprinkler threads: [1/2-inch NPT][ISO 7-R1/2] Sprinkler Temperature Rating: [135°F (57°C)][155°E (68°C)][175°E (79°C)][200°F (93°C)][286°E (141°C)] Sprinkler Finish Escutcheon Model: [F1][E2][FP] Escutcheon Finish (where applicable) Cover plate Model: [standard profile CCP 1/2-inch (12.7mm) adjustment][low profile CCP 5/16-inch (8.0mm) adjustment] Cover plate Temperature Rating: [135°F (57°C) for use with Ordinary Temperature sprinklers][ 1 650F (74°C) for use with Intermediate Temperature sprinklers] Cover plate Finish Note: When Model F1FR Series Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. 7. Reliable ... For Complete Protection' Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Automatic sprinklers Flush automatic sprinklers Recessed automatic sprinklers Concealed automatic sprinklers Adjustable automatic sprinklers Dry automatic sprinklers Intermediate level sprinklers Open sprinklers Spray nozzles Alarm valves Retarding chambers Dry pipe valves Accelerators for dry pipe valves Mechanical sprinkler alarms Electrical sprinkler alarm switches Water flow detectors Deluge valves Detector check valves Check valves Electrical system Sprinkler emergency cabinets Sprinkler wrenches Sprinkler escutcheons and guards Inspectors test connections Sight drains Ball drips and drum drips Control valve seals Air maintenance devices Air compressors Pressure gauges Identification signs Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for almost 100 years. Manufactured by Reliable Automatic Sprinkler Co., Inc. Recycled (800) 431-1588 Sales Offices Paper II eli able (914) 829-2042 Corporate Offices (800) 848-6051 Sales Fax Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 11/17 P/N 9999970300 tqco Fire Protection Worldwide Contacts I www.tyco-fire.com Products Series RFII - 56 K-factor "Royal Flush II" Concealed Pendent Sprinklers Quick & Standard Response, Standard Coverage General Description The TYCO Series RFII 5.6 K-factor, "Royal Flush II" Concealed Pendent Sprinklers Quick Response (3-mm bulb) and Standard Response (5-mm bulb), are decorative sprinklers fea- turing a flat cover plate designed to conceal the sprinkler. These sprinklers are optimal for architecturally sensi- tive areas such as hotel lobbies, office buildings, churches, and restaurants. Each sprinkler includes a Cover Plate! Retainer Assembly and a Sprinkler! Support Cup Assembly. The separa- ble, two-piece assembly design pro- vides the following benefits: Allows installation of the sprinklers and pressure testing of the fire pro- tection system prior to installation of a suspended ceiling or application of the finish coating to a fixed ceiling. Permits the removal of suspended ceiling panels for access to building service equipment without having to first shut down the fire protection system and remove sprinklers. Provides for 1!2 inch (12,7 mm) of vertical adjustment to allow a measure of flexibility in determining the length of fixed piping to cut for the sprinkler drops. The Series RFII Sprinklers are shipped with a Disposable Protective Cap. The Protective Cap is temporarily removed during installation and replaced to help protect the sprinkler during ceiling installation or finish. The tip of the Pro- IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinklersystems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 tective Cap can be used to mark the center of the ceiling hole into plaster board or ceiling tiles by gently pushing the ceiling product against the Pro- tective Cap. When ceiling installa- tion is complete, the Protective Cap is removed and the Cover Plate/Retainer Assembly is installed. As an option, the Series RFll Standard Response (5-mm bulb) "Royal Flush II" Concealed Pendent Sprinklers can be fitted with a silicone Air and Dust Seal. (Refer to Figure 5.) The Air and Dust Seal is intended for sensitive areas where it is desirable to prevent air and dust from the area above the ceiling to pass through the cover plate. The Series RFII Concealed Pendent Sprinklers described herein must be installed and maintained in compliance with this document and with the appli- cable standards of the National Fire Protection Association, in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY3531 - 3 mm bulb TY3551 - 5 mm bulb APRIL 2016 Technical Data Sprinkler Approvals Approvals apply only to the service conditions indicated in the Design Criteria section. TY3531 (3 mm Bulb) is UL Listed, C-UL Listed and NYC Approved (MEA 353-01-E) as Quick Response. TY3531 (3 mm Bulb) is VdS Approved (Certificate No. G4090007). TY3531 (3 mm Bulb) is FM and LPCB Approved (Ref. No. 094a/10) as Standard Response. Note: FM and LPCB do not approve concealed sprinklers for quick response. TY3551 (5 mm Bulb) is UL Listed, C-UL Listed, FM Approved, LPCB Approved (Ref. No. 094a/9), and NYC Approved (MEA 353-01-E) as Standard Response. Approvals for Air and Dust Seal UL and C-UL Listed for use with the RFll Standard Response Concealed Sprinkler (TY3551) Maximum Working Pressure Maximum 250 psi (17,3 bar) by UL, C-UL, and NYC Maximum 175 psi (12,1 bar) by FM, VdS, and LPCB Temperature Rating 155°F (68°C) Sprinkler with 139°F (59°C) Plate 200°F (93°C) Sprinkler with 165°F (74°C) Plate Discharge Coefficient K= 5.6 GPM/p5i1/2 (80,6 LPM/barl/2) TFPI8I SPRINKLER/SUPPORT CUP ASSEMBLY THREAD INTO RETAINER SUPPORT WITH THREAD CUP UNTIL 0 0 %_— DIMPLES MOUNTING SURFACE IS EJECTION FLUSH WITH SPRING CEILING / SOLDER ' '-_. COVER TABS (3) COVER PLATE/RETAINER PLATE ASSEMBLY FIGURE 1 MODEL RFII CONCEALED SPRINKLER ASSEMBLY EALING SEMBLY CAP BULB PRESSION 'CREW LECTOR ROPPED POSITION) 1/2 NPT FRAME SUPPOR CUP WITI ROLL FOR THREAD GUIDE PINS (2) DEFLECTOR TFPIBI Page 2 of 4 Adjustment 1/2 inch (12,7 mm) Finishes See the Ordering Procedure section. Physical Characteristics Frame ............................Bronze Support Cup ............Chrome Plated Steel Guide Pins..................Stainless Steel Deflector ..........................Bronze Compression Screw ..................Brass Bulb...............................Glass Cap .....................Bronze or Copper Sealing Assembly. . Beryllium Nickel w/TEFLON Cover Plate .........................Brass Retainer............................Brass Ejection Spring ..............Stainless Steel Design Criteria The TYCO Series RFII 5.6 K-factor, "Royal Flush II" Concealed Pendent Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency; for example, UL Listing is based on NFPA 13 and VdS Approval is based on the CEA 4001. For more information on LPCB and VdS Approvals, contact Tyco Fire Protection Products at the following office: Enschede, Netherlands Telephone: 31-53-428-4444 Fax: 31-53-428-3377 The Series RFII Concealed Pendent Sprinklers are only listed and approved with the Series RFII Concealed Cover Plates having a factory applied finish. i•iti Do not use the Series RFII in applica- tions where the air pressure above the ceiling is greater than that below. Down drafts through the Sprinkler/Support Cup Assembly can delay sprinkler operation in a fire situation. Operation When exposed to heat from a fire, the Cover Plate, normally soldered to the Retainer at three points, falls away to expose the Sprinkler/Support Cup Assembly. The Deflector - supported by the Guide Pins - then drops down to its operational position. The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, activating the sprinkler and allowing water to flow. Installation The TYCO Series RFII 5.6 K-factor, "Royal Flush II" Concealed Pendent Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 155°F (68°C) and 3/32 inch (2,4 mm) for the 200°F (93°C) tem- perature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a minimum to maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Sprinkler by under- or over-tightening the Sprin- kler/Support Cup Assembly. Re-adjust the position of the sprinkler fitting to suit. Step 1. Install the sprinkler only in the pendent position with the center-line of the sprinkler perpendicular to the mounting surface. Step 2. Remove the Protective Cap. Step 3. With pipe thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 4. Wrench-tighten the sprinkler using only the RFII Sprinkler Wrench. (Refer to Figure 3.) Apply the RFlI Sprinkler Wrench to the Sprinkler as shown in Figure 3. \ 3/16 to 11/16° MANUFACTURER DEFLECTOR COVER PLATE (4,8 to 17,5 mm) PRESET GAP IN DROPPED RETAINER REFERENCE 3/32° (2,4 mm) POSITION ASSEMBLY COVER PLATE PROFILE DEPTH DIMENSION B 3-1/4 inches (82,6 mm) 3/16 inches (4,8 mm) COVER PLATE DIAMETER DIMENSION A 2-3/8 to 2-5/8 inches (60,3 to 66,7 mm) 1-3/4 to 2-1/4 inches (44,5 to 57,2 mm) FIGURE 2 SERIES CONCEALED SPRINKLER INSTALLATION DIMENSIONS TFPISI Page 3 of 4 FACE OF SPRINKLER FITTING SPRINKLER SUPPORT CUP ASSEMBLY 1/2 (12,7 mm) THREADED D ADJUSTMENT FACE OF CEILING, RETAINING RING MOUNTING SURFACE CLEARANCE HOLE - DIAMETER - DIMENSION C Step 5. Replace the Protective Cap by pushing it upwards until it bottoms out against the Support Cup. (Refer to Figure 4.) The Protective Cap helps prevent damage to the Deflector and Arms during ceiling installation and/or finish. You can also use the Protective Cap to locate the center of the clear- ance hole by gently pushing the ceiling material up against the center point of the Protective Cap. t.iti.i As long as the Protective Cap remains in place, the system is considered "Out of Service". Step 6. After the ceiling has been completed with the 2-1/2 inch (63,5 mm) diameter clearance hole and in preparation for installing the Cover Plate/Retainer Assembly, remove and discard the Protective Cap. Verify that the Deflector moves up and down freely. If the Sprinkler is damaged and the Deflector does not move up and down freely, replace the entire Sprinkler. Do not attempt to modify or repair a damaged sprinkler. Step 7. When installing an Air and Dust Seal, refer to Figure 5; otherwise, proceed to Step 8. To attach the Air and Dust Seal, verify the angle of the outside edge of the seal is oriented according to Figure 5. Start the edge of the Retainer in the grooved slot of the Air and Dust Seal and continue around the retainer until the entire Air and Dust Seal is engaged. TFPI8I Page 4 of 4 SUPPORT SPRINKLER FACE OF ORIENT CUP CEILING SEAL BEVEL AS COVER \ SHOWN PLATE RETAINER ASSEMBLY / AIR AND DUST LIP OF COVER SEAL RETAINER PLATE FIGURE 5 OPTIONAL AIR AND DUST SEAL FOR SERIES RFII (TY3551) Step 8. Screw on the Cover Plate! Retainer Assembly until the Retainer (shown in Figure 2) or the Air and Dust Seal (shown in Figure 5) contacts the ceiling. Do not continue to screw on the Cover Plate/Retainer Assembly so that it lifts a ceiling panel out of its normal position. If you cannot engage the Cover Plate/Retainer Assembly with the Support Cup or you cannot engage the Cover Plate/Retainer Assembly suf- ficiently to contact the ceiling, you must reposition the Sprinkler Fitting. Care and Maintenance The TYCO Series RFII 5.6 K-factor, Royal Flush II" Concealed Pendent Sprinklers must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection system from the proper authorities and notify all personnel who may be affected by this action. Absence of the Cover Plate/Retainer Assembly can delay sprinkler opera- tion in a fire situation. When properly installed, there is a nominal 3/32 inch (2,4 mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 2. This air gap is necessary for proper operation of the sprinkler. If the ceiling requires repainting after sprinkler installation, ensure that the new paint does not seal off any of the air gap. Do not pull the Cover Plate relative to the Enclosure. Separation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers - before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installa- tion Section.) Exercise care to avoid damage to sprin- klers before, during, and after instal- lation. Replace sprinklers damaged by dropping, striking, wrench twist- ing, wrench slipping, or the like. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Refer to the Installation section.) If you must remove a sprinkler, do not reinstall it or a replacement without reinstalling the Cover Plate/Retainer Assembly. If a Cover Plate/Retainer Assembly becomes dislodged during service, replace it immediately. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or sprinkler manufac- turer regarding any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national code. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name. Sprinkler/Support Cup Assembly Specify: Series RFII (specify SIN), K=5.6, "Royal Flush II" Pendent Sprin- klers (specify) temperature rating and (specify) finish, P/N* (specify): 155°F (68°C) 200°F (93°C) TY3531 51-792-1-155 51-792-1-200 TY3551 51-790-1-155 51-790-1-200 * Use Suffix "I" for ISO 7-1 connection; for example, 51-792-1-155-I Separately Ordered Cover Plate/ Retainer Assembly: Specify: (temperature rating from below) Series RFII Concealed Cover Plate with (finish), P/N (specify). 139°F (59°C)(a) 165°F (74°C)(b) Grey White (RAL9002) .... 56-792-0-135 56-792-0-165 Brass..........56-792-1-135 56-792-1-165 Pure White (c) (RAL9010) .... 56-792-3-135 56-792-3-165 Signal White (RAL9003) .... 56-792-4-135 56-792-4-165 Jet Black (RAL9005).... 56-792-6-135 59-792-6-165 Brushed Chrome ........56-792-8-135 56-792-8-165 Chrome........56-792-9-135 56-792-9-165 Custom ........56-792-X-135 56-792-X-165 For use with 155°F (68°C) sprinklers. For use with 200°F (93°C) sprinklers. Eastern Hemisphere sales only. Sprinkler Wrench Specify: RFII Sprinkler Wrench, P/N 56-000-1-075 Air and Dust Seal Specify: Air and Dust Seal, P/N 56-908-1-001 GLOBAL HEADQUARTERS 1 1400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700 Copyright © 2016 Tyco Fire Products, LP. All rights reserved. tqco TEFLON is trademark of The DuPont Corporation Fire Protection Products