HomeMy WebLinkAbout6184 INNOVATION WAY; ; FA120019; Permit8/17/22, 4:47 PM FA120019 Permit Data
City of Carlsbad
Fire Alarm Permit
Permit No: FA120019
6184 INNOVATION
Job Address: Status: PENDING
WY
Permit Type: FALARM Applied 4/12/2012
Parcel No: 2132621407 Approved:
Lot #: 0
Reference No.: Issued:
PC #: Inspector:
Project Title: DICKINSON CAMERON T.I.
Applicant:
AMERICAN ALARM SYSTEMS
SUITE G
SANTA ANA, CA
714-547-7474
Owner:
6184 INNOVATION WAY L L C
5861 EDISON PL
CARLSBAD CA
Fees ($) Add'I Fees ($) Total ($) Balance ($)
257 0 257 0
1/1
FILr ccry FUNDAMENTALS OF FIRE ALARM SYSTEMS 72-31
FIRE ALARM SYSTEM
RECORD OF COMPLETION
Name of protected property: - i C-2 J f\) .O
Address:_ 1;1-$ i 1
/
Authority having jurisdiction: Address/telephone number:
Representative of protected property (name/phone):
Organization name /phone Representative name/phone
Installer mFQtA P.LA .w. 314 1I1A I\5 LOON Supplier tiiALA S+4rb. 1i' VN14 .cJ- Th' 711E tbO Service organization P.J t-pii Location of record (as-built) drawings: w*_Lp .i_L_S.1 Location of operation and maintenance manuals: frt__f_P.c..P
Location of test reports: kT_W%Q-12P-1 S+âw _k1_4A_P A contract for test and inspection ii accordance with NFPA standard(s)
Contract No(s): 5 CG 4 Effective date: Expiration date:
System Software
Operating system (executive) software revision level(s)
Site-specific software revisi ate: tJ
Revision completed by: &Lg.Lr, &f6 (name) (firm)
1. Type(s) of System or Service
N NFPA 72, Chapter 6 -Local
If alarm is transmitted to location (p) off premises, list where received: P,acIM _tLIkv _-è6re_Uc I_Cc,_2-7o
NFPA 72, Chapter 8 - Remote Station
Telephone numbers of the organization receiving alarm:
Alarm: •f 51 1L&7&4
Supervisory: 7114 S4-74
Trouble: 1 5i1 7416
If alarms are retransmitted to public fire service communications centers or others, indicate location and telephone
numbers of the organization receiving alarm:
Indicate how alarm is retransmitted:
NFPA 72, Chapter 8 - Proprietary
Telephone numbers of the organization receiving alarm:
Alarm: --- -
Supervisory:
Trouble:
If alarms are retransmitted to public fire service communications centers or others, indicate location and telephone
numbers of the organization receiving alarm:
Indicate how alarm is retransmitted:
--4 NFPA 72, Chapter 8 - Central Station
Prime contractor: 0_Q...
Central station location: I 116 1 S GXA tA_ 0_ki
FIGURE 4.5.2.1 Record of Completion.
(NFPA 72,1 of 4)
2002 Edition
72-32 NATIONAL FIRE ALARM CODE
Means of transmission of signals from the protected premises to the central station:
McCulloh Multiplex One-way radio
Digital alarm communicator \i Two-way radio _______ Others
Means of transmission of alarms to the public fire service communications center:
System location:
NFPA 72, Chapter 9— Auxillary
Indicate type of connection: _______ Local energy _______ Shunt N Parallel telephone
Location of telephone number for receipt of signals: XTFcA! CE taT 11be i... STPTIO4
2. Record of System Installation
(Fill out after installation is complete and wiring is checked for opens, shorts, ground faults, and improper branching,
but prior to conducting operational acceptance tests.)
This stem has been installed in accordance with the NFPA standards as shown below, was inspected by
on '72 I Z , includes the devices shown in 5 and 6, and has been in service since i Z2 I Z
NFPA 72, Chapters 678 11 (circle all that apply)
NFPA 70, National Electrical Code, Article 760
Manufacturer's instructions
Other (specify):
Signed2G.J.., d Date:
Organization: i A j4 c+6m
3. Record of System Operation
Documentation in accordance with Inspection Testing Form, Figure 1021-is attached
'_.. All operational features and functions of this system were tested by_J7• date 5 /_2 and found to be operating properly in accordance with the requirements of:
.LNF.PA 72, Chapters J6789 11 (circle all that apply)
NFPA 70, National Electrical Code, Article 760
- Manufacturer's instructions
- Other Cs ecify):
Signed: Date: 5/2 z/ t z
Organization:
Signaling Line Circuits
Quantity and class of signaling line circuits connected to system (see NFPA 72, Table 6.6.1):
Quantity: .) Style: O _____________ Class: ___
(NFPA 72,2 014)
FIGURE 4.5.2.1 Continued
2002 Edition
FUNDAMENTALS OF FIRE ALARM SYSTEMS 72—S
5. Alarm-Initiating Devices and Circuits
Quantity and class of initiating device cirt 1 ee NFPA 72, Table 6.5):
Quantity:. Style: ____________ Class: _________________________________
MANUAL
(a) Manual stations Noncoded Transmitters-
(b) Combination manual fire alarm and guard's tour. coded stations
AUTOMATIC
Coverage: Complete
Selective
Coded _________ Addressable
Partial
Nonrequired
Smoke detectors_ Ion Photo-- Addressable__________
Duct detectors Ion Photo Addressable k—
Heat detedtors FT RR FT/RR RC_________ Addressable
Sprinkler waterfiow indicators: Transmitters Noncoded_._ Coded Addressable
The alarm verification feature is d±oci-blnd - - or enabled. - ,changed from seconds to seconds.
(0 Other (list):
çk c)
6. Supervisory Signal-Initiating Devices and Circuits (use blanks to indicate quantity of devices)
GUARD'S TOUR
(a)............... Coded stations
(b)......._Noncoded stations
(c) Compulsory guard's tour system comprised of _____________ transmitter stations and intermediate stations
Note: Combination devices are recorded under 5(b), Manual, and 6(a), Guard's Tour.
SPRINKLER SYSTEM
Check if provided
Valve supervisory switches
(b).._... Building temperature points
(c) Site water temperature points
(d)_.._......... Site water supply level points
Electric fire pump:
(e)—Fire pump power
(0 Fire pump running
(g)............... Phase reversal
Engine-driven fire pump:
(h)............. Selector in auto position
Engine or control panel trouble
Fire pump running
ENGINE-DRIVEN GENERATOR:
(a).................. Selector in auto position
(b)........ Control panel trouble
(c) ...............Transfer switches
(d).......Engine running
Other supervisory function(s) (specify):
(NFPA 723of4)
FIGURE 4.5.2.1 Continued
2002 Edition
72-34 NATIONAL FIRE ALARM CODE
7. Annunciator(s)
Number J Type: Location: A0 t..-a 6j
8. Alarm Notification Appliances and Circuits
NFPA 72, Chapter 6 - Emergency Voice/Alarm Service
Quantity of voice/alarm ch els: Single: Multiple:_
Quantity of speakers installed: i' . Quantity of speaker zones:_ Quantity of telephones or telephone j ' eluded in system:
Quantity and the class of notification appliance 'rcuits connected to system (see NFPA 72, Table 6.71:
Quantity: 4 Style: \ftf Class:
Types and quantities of notification appliances installed:
Bells With Visible
Speakers With Visible
Horns.. With Visible
Chimes With Visible
Other: With Visible
(1) Visible appliances without audible:
9. System Power Supplies
Fire Alarm Control Panel: Nominal voltage: 17.0 "J Current rating: 2D Aw P Overcurrent protection: Type: g*Km._ Current rating: 2D P.ry r Location:
Secondary (standby):
Storage battery: Z) Dc.. Amp-hour rating:
Calculated capacity to drive system, in hours: ? 71
Engine-driven generator dedicated to fire alarn) system:______________________
Location of fuel storage:
Emergency system used as backup to primary power supply:__'.f
Eniergency system described in NFPA 70, Article 700:
10. Comments
Frequency of routine tests and inspections, if other than in accordance with the referenced NFPA standard(s):
System deviations from the referenced NFPA standard(s).are:
alarm service company (title)
(signed) for central station (title) (date)
Upon completion of the system(s) satisfactory test(s) witnessed (if required by the authority having jurisdiction):
(signed) representative of the authority having jurisdiction (title) (date)
(NFPA 72, 4 of 4)
FIGURE 4.5.2.1 Continued
2002 Edition