5345 ARMADA DR; ; FPC2017-0260; Permit
PIERMET REPORT N kk'\! 0 91:44 I A~D F~)~ Print Date: 08/30/2022 Permit No: FPC2017-0260 Job Address: 5345 ARMADA DR, CARLSBAD, CA 92008-4602 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2110231700 Track #: Applied: 09/05/2017 Valuation: $762810.51 Lot #: Issued: 10/06/2017 Occupancy Group: Project #: Finaled Close Out: 03/09/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check #: INSPECTOR: Wong, Cindy Plan Check #: Project Title: Description: GIA - FIRE ALARM Applicant: FPContractor: MARIO FLORES JOHNSON CONTROLS FIRE PROTECTION LP 3568 RUFFIN RD P0 BOX 3042 SAN DIEGO, CA 92123-2597 BOCA RATON, FL 33431-0942 (858) 633-9109 (561) 341-7780 FEE AMOUNT FIRE TI Fire Alarm System $601.00 Total Fees: $601.00 Total Payments To Date: $601.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov FIRE ALARM SYSTEM EQUIPMENT SUBMITTAL FOR GIA BUILDING "C" 2ND FLOOR TENANT IMPROVEMENT 5345 ARMADA DRIVE CARLSBAD, CALIF. 92008 FPC20I7-0260 5345 ARMADA DR B®Simplex LifeAlarm Fire Alarm Controls S UL, ULC, CSFM Listed; FM Approved; 4009 IDNet NAC Extender for Control with MEA (NYC) Acceptance* IDNet Communications or Conventional NACs BMW 4-1 - Provides additional notification appliance circuit (NAC) capacity with flexible operation modes and power-limited design Upto8NACs Four, Class B NACs are standard: Rated 2 A each for conventional reverse polarity 4009 IDNet 24 VDC notification appliances and providing NACExtender multiple operation modes Can be selected to provide synchronization for Simplex® visible notification strobe flashes Capable of controlling TrueAlert non-addressable _______________ Optional IDNet Channel Repeater notification appliances operating with SmartSync two-wire control mode** MINIMUM j * h" Input control options: ' IDNet addressable communications from a Simplex 2-Wire IDNet model 4007E5, 4010, 4010ES, 4100ES, or 4100U Fire Communications or \ Alarm Control Panel** - Fiber Optic IDNet \ Or from one or two conventional 24 VDC NACs with Communications ar multiple output control options NAC Control I * - IDNet communications control benefits: Provides status monitoring and individual NAC control IDNet Fiber I using a single address per 4009 IDNet NAC Extender Optic Transmitter Supports IDNet "Device Level" earth fault location WALKTEST operation is available with either 4007ES, 4010 (shown), input choice 4010ES, 4100ES, or4100U I Internal 8 A power supply/battery charger: Fire Alarm Control Panel I Charges internal batteries up to 12.7 Ah or up to 18 Ah Fire Alarm Control Panel with batteries in external cabinet Conventional NACs Provides status monitoring of battery, input power, and 4009 IDNet NAC Extender Connection Reference Drawing earth faults urnrrrri Rated 8 A for "Special Application" appliances; including Simplex 4901, 4903, 4904, and 4906 Series ADA Compliance. Complying with the notification horns, strobes, horn/strobes, and speaker/strobes requirements of ADA (Americans with Disabilities Act) Rated 6 A for "Regulated 24 DC" appliance power may require more notification appliance power than is available within the fire alarm control panel. When Optional 4009 IDNet NAC Extender modules: additional power is required, a Simplex 4009 IDNet NAC IDNet Communications Repeater provides Class B or Extender can provide up to 8 A of NAC power with up to Class A output eight, supervised reverse polarity NACs. IDNet Communications Fiber Optic Receiver/Repeater, available as Class B or Class X Location Flexibility. The 4009 IDNet NAC Extender Four additional Class B NACs, rated 1.5 A for Special can be mounted close to a compatible dedicated host panel or can be located remotely for convenient power Application appliances; 1 A for Regulated 24 DC distribution. Multiple operation modes and multiple appliance power Class A, Two Circuit Adapter Module connection options further increase location flexibility. Additional Information. For additional operation detail UL Listed to Standard 864 and application information, refer to Installation 1747- RPM M Instructions 574-181 and field wiring diagram 842-068. IDNet communication fiber optic transmitters: * ULC listed model is 4009-9202CA. This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and For applications requiring the data integrity available Safety Code. See CSFM Listing 7300-0026:214 for allowable valves and/or conditions S with fiber optic communications concerning matenal presented in this document Accepted for use - City of New York Available as Class B or Class X Department of Buildings - MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Mounts in standard six-gang electrical box Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. External battery cabinet for 18 Ah batteries 4100U requires revision 11 software or higher for compatibility. 4010 requires revision 2 software or higher for compatibility. S4009-0002-14 9/2015 Application and Operation Information IDNet Addressable Communications Compatible. Up to ten (10), 4009 IDNet NAG Extenders can be controlled per 4007ES, 4010ES, 4100ES, or 4100U IDNet communications channel; up to five (5) can be controlled on the 4010 IDNet communications channel. Each output NAC can be individually controlled for general alarm or selective area notification requiring only one point address per Extender. Individual Extender NACs can also be manually controlled from the host panel. IDNet controlled extenders will inform the host panel of troubles via IDNet communications. 4007ES, 40IOES, 4100ES, and 4100U control panels control using multi-point rules, refer to data sheet S4090-0011 for details. Hardwire Control Applications. For applications where an existing (or new) conventional NAC needs additional power, the 4009 IDNet NAC Extender can be controlled directly from the NAG. Either one or two NACs, from either the same, or from different host fire alarm control panels, can be connected to control the 4009 IDNet NAG Extender output NACs. Multiple control selections provide flexible operation. (Refer to page 4 for more detail.) Alarms from the host panel will activate the four, 4009 IDNet NAG Extender NACs (or optionally, eight NACs) to extend the alarm. The 4009 IDNet Extender monitors itself and each of its output NACs for trouble conditions, including earth faults. Extenders wired to conventional NACs will Optional IDNet Repeaters. IDNet communications can indicate a trouble by opening the path to the NAG's be repeated with the optional IDNet Repeater Module or end-of-line resistor, but retaining the ability to respond to with the optional Fiber Optic Receiver Module. Up to 100 alarms. Individual troubles are also annunciated by LEDs of the IDNet channel points can be repeated once (refer to located on the 4009 IDNet NAG Extender main circuit pages 3 and 5 for details). Repeated IDNet communications board. (Refer to page 7 for more diagnostic information.) also support the "device level" earth fault location utility of the host panel. 3T.N. rrNM- Standard Models Model Description 40099201* 120 VAC input 4009 IDNet NAC Extender with 4, Class B NACs and 8 A power supply 4009-9301 * ULC listed model ** 4009-9201 has been seismic tested and is certified to IBC and CBC standards as well as to ASCE 7 categories A through F, requires battery brackets as detailed on data sheet S2081-0019 Optional Modules (for on-site installation) Model 4009-9807 Description Additional four point NAC module, rated 1.5 A Special Application appliances; 1 A for Regulated 24 DC appliance power, Class B Comments One maximum 4009-9808 Dual Class A adapter (for two NAC outputs) Select as required (4 maximum) 4009-9809 IDNet Repeater, output is Class A or Class B Select either an IDNet Repeater or a Fiber Optic Receiver as required; one transmitter can connect to one receiver 4009-9810 Fiber Optic Receiver Class B 4009-9811 Class A (IDNet), Class X (fiber) 4009-9805 Red Appliqué for door Select if required 2975-9801 Semi-Flush Trim Kit eige trim 1-7/16" wide (78 mm), use if required for semi-flush installations 2975-9802 ~Red trim Battery Selection (select battery size per system requirements) Model Description Comments 2081-9272 6.2 Ah Battery, 12 VDC 2081-9274 10 Ah Battery, 12 VDC Two batteries are required, 24 VDC operation 2081-9288 12.7 Ah Battery, 12 VDC 2081-9275 18 Ah Battery, 12 VDC Requires external battery cabinet, two batteries are required, 24 VDC operation External Accessories (select per system requirements) Model Description Comments 4090-9105 IDNet Fiber Optic I Class B operation Mounts in six-gang electrical box, refer to 4090-9107 Transmitter Class X operation page 4 for mounting details 4009-9801 External battery cabinet for up to 18 Ah batteries, beige 16-1/4" W 13-1/2" H x 5-3/4" D (413 mm x 343 mm x 146 mm) 4081 Series I End-of-Line Resistor Harnesses; see data sheet S4081-0003 for details S4009-0002-14 9/2015 4090-9105, Class B (Style 4) Output Fiber Optic Transmitter Two fiber cable ft (914 m) maximurr Typical IDNet Connection Example 4007ES, 4010, 4010ES, 4IOOES (shown), or 41001-1 Fire Alarm Control Panel Output NACs, four standard, eight with expansion option Conventional NAC operation (horns) Select conventional or SmartSync operation per NAC Typical IDNet compatible devices (Refer to individual devices for actual wiring requirements, some wiring is not shown.) 'IDNet addressable communications channel, shown Class B (Style 4) SmartSync operation (horns and strobes) 4009 IDNet NAC Extender with optional internal IDNet Repeater Conventional NAC operation (strobes) Reoeated IDNet Channel: up to 100 devices maximum on repeater output, 250 devices total on IDNet Channel IDNet devices and additional 4009 IDNet NAC Extender(s) fe NOTE: Up to ten (10) 4009 IDNet NAC Extenders maybe connected per 4007ES, 4010ES, 4100ES, or 4100U IDNet channel, up to five (5) on the 4010 IDNet channel. IDNet communications can be repeated only once (can pass through only one series connected repeater or one fiber optic receiver). Typical Fiber Optic System Connections IDNet addressable communications channel Class B (Style 4) or Class A (Style 6), Class B shown 7 Reoeated it(e( Channel: up to 100 devices maximum on repeater output, 250 devices total on IDNet Channel 4007ES, 4010 (shown), 4010ES, 4100ES, or4looli Fire Alarm Control Panel Lour fiber cables, 3000 ft (914 m) maximum dista 24 VDC power for fiber optic transmitters 4090-9107, Class A (Style 7) Output Fiber Optic Transmitter ¼JULPUL 4009 IDNet NAC Extenders internal IDNet Fiber Receivers NOTE: Up to ten (10) 4009 IDNet NAC Extenders maybe connected per 4007ES, 40I0ES, 4I00ES, or 4100U IDNet channel, up to five (5) on the 4010 IDNet channel. IDNet communications can be repeated only once (can pass through only one series connected repeater or one fiber optic receiver). Fiber optic transmitters connect to only one receiver in a 4009 IDNet NAC Extender. S4009-0002-14 9/2015 NAC Input Selections. The 4009 IDNet NAC Extender can be selected to: Track input NAC operation or to provide a locally generated code, selectable per NAC input If selected for local coding, NAC outputs can be either Temporal Coded or 60 Beats/min March Time Coded, one code selection per extender (input NACs must be on continuous with Alarm) Additionally, NAC outputs can be selected to provide the Simplex strobe synchronization signal. This signal will synchronize the flashes of synchronized strobes but will be ignored by free-run strobes and audible devices. (Strobes are for operation by noncoded NACs.) NAC input to NAC output control can be selected for standard and optional NACs per the following table: Conventional NAC Output Operation Options Input A B C NAC1 NACs1 &2,5&6 NACs 1-4 NACs 1-8 NAC2 NACs 3&4,7&8 NACs 5-8 None SmartSync NAC Output Operation Input NAC Control Function NAC 1 Strobe Control I All NAC outputs (1-8) NAC 2 Horn Control I SmartSvnr Nttificition Annlianrp Cnntrnl The TrueAlert Notification Appliance product line includes addressable and non-addressable operation. Non-addressable models are available with 2-wire SmartSync operation or conventional 4-wire operation. The following details apply to use with the 4009 IDNet NAC Extender: TrueAlert non-addressable models with SmartSync operation allow audible notification to be separately controlled over the same wire pair that controls visible notification 4009 IDNet NAC Extenders can be selected to provide SmartSync operation whether controlled by IDNet communications or conventional NACs IDNet control allows output NACs to be individually selected for conventional or SmartSync operation With NAC input control, all output NACs are selected for either conventional or SmartSync operation Refer to data sheet S4009-0003 for TrueAlert Addressable operation details, contact your local Simplex product supplier for further information on specific TrueAlert notification appliances S Hardwire Control NAC Connection One-Line Reference Diagram Up to eight (8) output NACs total; hardwire control can be selected to map NAG inputs to different combinations of NAG outputs depending on system requirements NAC 1 input (see Note 1) Conventional NAGs., With hardwire control, NAG outputs are all _______ Output conventional oral! [ 0---- ---_______ NACs SmartSync operation Fire Alarm Control Panel I with Conventional NACs / SrnartSync operation — I Class A operation, either mode, requires NAG 2 input 4009-9808 Dual Class A Adapter (optional, see Note 1) ] To additional 4009 IDNet NAG Extenders (up to four (4), - -4009 IDNet NAG Extenders per NAG); see Note 2 Notes: For separate audible and visible output NAC control, or SmartSync NAC output operation, two (2) input NACs are required. NAG 1 is "on-until-reset" and NAG 2 is "on-until-silenced." To synchronize strobe flash outputs for up to four (4) 4009 IDNet NAG Extenders, use the synchronized strobe output from a Synchronized Flash Module (4905-9914 for Glass B operation, 4905-9922 for Glass A operation) or, if available, from a NAG selected to provide synchronized strobe flash output. NOTE: DO NOT USE a NAC selected for SmartSync operation for this function. Refer to Installation Instructions 574-181 for additional information and application guidance S4009-0002-14 9/2015 120 VAC Input (4009-9201) 3A@ 102-132 VAC, 60 Hz Input Ratings 240 VAC Input (4009-9301) Hardwire Control from External NACs, Input Requirements 1.5A@ 204264 VAC, 50/60 Hz Conventional reverse polarity operation 5 mA maximum; 16 to 33 VDC Output Ratings Total Rating8 Standard NACs Optional NACs (requires 4009-9807) Special Application Appliances Regulated 24 DC Appliances Strobe Operation Auxiliary Output A, Special Application appliances 6 A, Regulated 24 DC appliance power 2 A each, Special Application or Regulated 24 DC appliance power 1.5 A each, Special Application appliances 1 A each, Regulated 24 DC appliance power Simplex non-addressable horns, strobes, and combination horn/strobes and speaker/strobes (contact your Simplex product representative for compatible appliances) Power for other UL listed appliances; use associated external synchronization modules where required Up to 33 strobes per NAC can be synchronized; output NACs configured for Simplex synchronized strobe operation are synchronized to each other 500 mA @ 24 VDC nominal Optional Modules Ratings IDNet Repeater Module (4009-9809) Input Power IDNet Input, One Address IDNet Output Specifications 70 mA @ 24 VDC, system supplied Maximum distance from IDNet source is 2500 ft (762 m) Repeated IDNet output for up to 100 devices (total IDNet devices not to exceed 250 per channel) Maximum distance to farthest device is 2500 ft (762 m) Total distance including "T-taps" is 10,000 ft (3048 m) Class A loop maximum distance is 2500 ft (762 m), no "T" taps Fiber Optic Receiver Modules I C 4009-9810, Class B, 65 mA© 24 VDC, system supplied Input Current 4009-9811, Class X, 80 mA © 24 VDC, system supplied IDNet Output Specifications Same as those for Repeater Module (see above) Fiber Optic Transmission Distance 3000 ft (914 m) maximum General (LED status indicators are listed on page 7, dimensions and mounting details are on page 6) Operating Temperature 32° to 120° F (0° to 49° C) Operating Humidity Range 10% to 90% RH from 32° F to 104° F (0° C to 40° C) Wiring Connections* Terminal blocks for 18 AWG (stranded) to 12 AWG (solid) I Input Voltage 18.9-32 VDC from compatible listed fire alarm supply Input Current 4090-9105, Class B, 30 mA@ 24 VDC 4090-9107, Class X, 35mA@24VDC Fiber Optic Connections and cable requirements Multimode, graded index, 50/125pm, 62.5/125 pm, 100/40 pm, or 200 pm Type ST connectors 4090-9105, Class B operation, two fiber cables required 4090-9107, Class X operation, four fiber cables required Module Size (with mounting bracket) 6-13/16" W 3-3/4" H x 1-1/8" D (173 mm x 95 mm x 29 mm) On-board Status Indicators Green LED flashing = transmit Red LED flashing = receive Separate red LED on 4090-9107 = Class X receive Communications Simplex IDNet Fiber Optic Transmission Distance 3000 ft (914 m) maximum Wiring Connections* Terminal blocks for 18 AWG (stranded) to 12 AWG (solid) Operating Humidity. 10% to 90% RH from 32° to 104° F (0° to 40° C) Operating Temperature 32° F to 120° F (0° to 49° C) * Metric wire equivalents: 18 AWG = 0.82 mm2; 12 AWG = 3.31 mm2 5 S4009-0002-14 9/2015 14009 IDNet NAC Extender Mounting and Module Placement Information i I Cabinet depth ,J 16-1/4 (413 mm) "4-1/4" (108 mm) I 10-29/32 (277 mm) I Door, 5/8 0 10 0 (16 mm) thick - 1 0 __ 0 1' Optional Class A 4009-9807AdditionalFou') 13-1/2" t adapter modules J I point module (shown with (343 mm) ClassAadapters)J © Exposed cabinet II . dimension for—I - tot. I System Module ") 0 OLJ]J], semi-flush mount tol' " _.1 t.LJ1 1" (25.4 mm), Knockouts for screw 1I1 ~Fi DNet repeater or I']I 1-3/8 (35 mm) with or nail mounting holes ber opticreceivef,) WI semi-flush trim 10 I3lj 0 1 0 —@ __I -- :4 12(3o5 mm) L '• Battery location, no conduit entry or wiring in this area (12.7 Ah battery outline shown) oo Semi-flush trim option - Non-power limited wiring area (AC input) 1-3/16" wide (30 mm), " 3/8" (9.5 mm) thick Wall surface reference for semi-flush mount'"" NOTE: Recommended conduit entrance varies with module selection. Refer to general installation instructions 574-181, specific module installation instructions, and to field wiring diagrams 842-068 before locating conduit entrance. 4009 IDNet NAC Extender Cabinet with Door Detail Optional red appliqué (4009-9805) 6 S4009-0002-14 9/2015 4090-9105/9107 IDNet Fiber Optic Transmitter Mounting Information Surface mount box: ___.j Simplex model 2975-9217 (ordered separately) I In fi fi fi fi C / Flush mount masonry box: use 6-gang box, RACO #960, 2-1/2" deep __________ OO O ° u° u°uO (64 mm), or RACO # 965, 3-1/2" (89 mm) deep, or equal (supplied by others) ____ Flush mount ganged boxes: U U 0 0 minimum depth; six, RACO #400 I • - use 6-gang box, 1-1/2 (38 mm) • 0 or equal, (supplied by others) m - i im ~7 [] o o 0 0 0 0 o o 0 0 0 IDNet fiber optic transmitter: 4090-9107, Shown, Class A (Style 7) output 4090-9105, Not shown, Class B (Style 4) output INSTALLATION NOTE: Fiber optic cable bend radius should be 2" (51 mm) minimum, or per Manufacturer's specification. Six-gang blank cover plate Mulberry Metal Products 97156 or equal (by others) F?2 F1 U]F:I,Iit.1IT -k' I(*I Power-up Self-Diagnostics. Upon power-up, the 4009 IDNet NAC Extender tests each module and performs earth fault diagnostics. Trouble conditions are communicated to the host control panel and are also displayed on diagnostic status LEDs in the 4009 IDNet NAC Extender. When connected via IDNet communications, detailed status information is available at the host. When controlled with conventional NAC inputs, common troubles are signaled by providing a polarized open circuit that disconnects the NAC wiring from its end-of-line resistor but still allows a reversed polarity alarm to be received. Door Mounted Reference Label. The 4009 IDNet NAC Extender has a detailed programming and diagnostic label inside the front door that provides a quick reference for both installation and checkout. LED Status Indicators are provided for the following: Each NAC (standard and optional) has a dedicated yellow LED that: - During supervision provides a slow flash to indicate a short circuit condition and a fast flash to indicate an open circuit - During an alarm, the LED follows the NAC output (on steady or flashing with coded output) Four, general status yellow LEDs provide nine separate indications listed in priority of urgency. As a trouble is eliminated, any remaining trouble(s) will then be indicated until the 4009 IDNet NAC Extender is returned to normal operation. AC power status is indicated by a green LED that is on when AC is normal. During low AC (brownout) conditions or with no AC, the LED is off. Additional power and battery status is indicated by the general status LEDs. 7 S4009-0002-14 9/2015 K11111:111110174 UFiI'iflTI Step 1. Calculate Basic Extender Battery Requirements (minus NAC loads) Panel, NAC Options, and Auxiliary Power (underlined model numbers are optional modules) Model Description Supervisory Su: tu :rvi ry Alarm Current Actual Alarm Current (4009-9201 120 VAC input Basic Panel 240 VAC input 85 mA 85 mA 185 mA 185 mA 4009-9301 4009-9807 Additional Four Point NAC 40 mA +_______ 40 mA +_______ 4009-9808 j Dual Class A Adapter (no additional current) - - - - Auxiliary Power Output (500 mA +_______ (509 mA maximum) maximum) + [Al] Basic Panel Supervisory Current = [SI] Basic Panel Alarm Current = [A2] SteR 2. Calculate IDNet Output Module and Device Current (if used) 4009-9809 IDNet Repeater Select one per Extender 70 mA +_______ 70 mA +_______ 40099810* Fiber Optic Receiver, Class B 1 65 mA 65 mA 400998II* Fiber Optic Receiver, Class X 80 mA 80 mA IDNet Devices (connected to Repeater or Receiver above), Total devices Total devices 0.7 mA each, maximum of 100 1 x 0.7 mA each + lxO.7mAeach +_______ * Note: IDNet Fiber Optic Transmitter IDNet Module Supervisory Current [S2] = current is supplied from the host fire alarm control panel IDNet Module Alarm Current = [A3] Maximum Available Current = 8 A* Step 2. Calculate Available NAC Current Subtract Auxiliary Power Output - [Al] - [A3] Subtract IDNet Module Current = [A4] * 8 A for Special Application Appliances; 6 A for Regulated 24 DC Appliances Available NAC Current Step 3. Calculate Actual NAC Loading (Limited to Available NAC Current per Step 2.) NAC Type NAC Circuit # NAC Alarm Current Circuit I +________ Circuit 2 +_______ Standard Panel NAGS, 2 A maximum per NAC Circuit 3 +_______ Circuit 4 +_______ Circuit 5 Optional Four Point NAC Module, 1.5 A maximum Special Application rating, Circuit 6 Circuit 7 +_______ 1 A maximum Regulated 24 DC rating, per NAC Circuit 8 +_______ Total Actual NAC Load Alarm Current = [A5] Stek 4. Calculate Total Supervisory Current Total Supervisory Current = Basic Panel Current [S11] + IDNet Module Current [S2] 5. Calculate Total Alarm Current Total Alarm Current = Basic Panel Current [A2] + IDNet Module Current [A3] + Actual NAC Current [A5] = I TYCO, SIMPLEX and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. ®S I rn p1 EX Tyco Fire Protection Products • Westminster, MA 01441-0001 USA S4009-0002-14 9/2015 C 2015 Tvco Fire Protection Products. All rig/its reserved All specifications and other information shown were current as of document revision date and are subject to change without notice. Simplex TrueAlarm Analog Sensing UL, ULC, CSFM Listed; FM Approved; TrueAlarm Analog Sensors - Photoelectric MEA (NYC) Acceptance* and Heat; Standard Bases and Accessories I1iu I TrueAlarm analog sensing provides: Digital transmission of analog sensor values via IDNet or MAPNET II two-wire communications For use with the following Simplex products: 4007ES, 4010, 4010ES, 4100ES, and 4100U Series control panels; and 4008 Series control panels with reduced feature set (refer to data sheet S4008-0001 for details) 4020, 4100, and 4120 Series control panels, Universal Transponders, and 2120 TrueAlarm CDTs equipped for MAPNET II operation Fire alarm control panel provides: Peak value logging allowing accurate analysis of each sensor for individual sensitivity selection Sensitivity monitoring satisfying NFPA 72 sensitivity testing requirements; automatic individual sensor calibration check verifies sensor integrity Automatic environmental compensation, multi-stage alarm operation, and display of sensitivity directly in percent per foot Ability to display and print detailed sensor information in plain English language Photoelectric smoke sensors provide: Seven levels of sensitivity from 0.2% to 3.7% (refer to additional information on page 3) Heat sensors provide: Three fixed temperature sensing thresholds: 135° F, 155° F and 190° F Rate-of-rise temperature sensing Utility temperature sensing Listed to UL 521 and ULC-5530 General features: Operation is for ceiling or wall mounting Listed to UL 268 and ULC-5529 Louvered smoke sensor design enhances smoke capture by directing flow to chamber; entrance areas are minimally visible when ceiling mounted Designed for EMI compatibility Magnetic test feature is provided Different bases are available to support a supervised or unsupervised output relay, and/or a remote LED alarm indicator Additional base reference: For isolator bases, refer to data sheet S4098-0025 For sounder bases, refer to data sheet S4098-0028 For photo/heat sensors, refer to data sheet S4098-0024 (single address) and S4098-0033 (dual address) ° These products have been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listings 7272-0026:218, 7271-0026:231 7270-0026:216, and 7300-0026:217 for allowable values and/or conditions concerning material presented in this document. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable, contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. r4098-9714 TrueAlarm Photoelectric Sensof Mounted in Base Description Digital Communication of Analog Sensing. TrueAlarm analog sensors provide an analog measurement digitally communicated to the host control panel using Simplex addressable communications. At the control panel, the data is analyzed and an average value is determined and stored. An alarm or other abnormal condition is determined by comparing the sensor's present value against its average value and time. Intelligent Data Evaluation. Monitoring each sensor's average value provides a continuously shifting reference point. This software filtering process compensates for environmental factors (dust, dirt, etc.) and component aging, providing an accurate reference for evaluating new activity. With this filtering, there is a significant reduction in the probability of false or nuisance alarms caused by shifts in sensitivity, either up or down. Control Panel Selection. Peak activity per sensor is stored to assist in evaluating specific locations. The alarm set point for each TrueAlarm sensor is determined at the host control panel, selectable as more or less sensitive as the individual application requires. Timed/Multi-Stage Selection. Sensor alarm set points can be programmed for timed automatic sensitivity selection (such as more sensitive at night, less sensitive during day). Control panel programming can also provide multi-stage operation per sensor. For example, a 0.2% level may cause a warning to prompt investigation while a 2.5% level may initiate an alarm. Sensor Alarm and Trouble LED Indication. Each sensor base's LED pulses to indicate communications with the panel. If the control panel determines a sensor is in alarm, or is dirty or has some other type of trouble, the details are annunciated at the control panel and that sensor base's LED will be turned on steadily. During a system alarm, the control panel will control the LEDs such that an LED indicating a trouble will return to pulsing to help identify the alarmed sensors. S4098-0019-23 8/2017 S TrueAlarm Sensor Bases and Accessories Base mounted address selection: Address remains with its programmed location Accessible from front (DIP switch under sensor) General features: Automatic identification provides default sensitivity when substituting sensor types Integral red LED for power-on (pulsing), or alarm or trouble (steady on) Locking anti-tamper design mounts on standard outlet box Magnetically operated functional test 4098-9792, Standard Sensor Base 4098-9789, Sens6r Base with wired connections for: 2098-9808 Remote LED alarm indicator or 4098-9822 relay (relay is unsupervised and requires separate 24 VDC) 1Supervised Relay Bases (not compatible with 2120 CDT): 4098-9791, 4-Wire Sensor Base, use with remote or locally mounted 2098-9737 relay, requires separate 24 VDC 4098-9780,2-Wire Sensor Base, use with remote or locally mounted 4098-9860 relay, no separate power required Supervised relay operation is programmable and can be manually operated from control panel Includes wired connections for remote LED alarm indicator or 4098-9822 relay (relay is unsupervised and requires separate 24 VDC) Fi- i1c:.] :is]I MT-1 2098-9737, Remote or local mount supervised relay: DPDT contacts for resistive/suppressed loads, power limited rating of 3 A @28 VDC; non-power limited rating of 3 A @ 120 VAC (requires external 24 VDC coil power) 4098-9860, Remote or local mount supervised relay: SPDT dry contacts, power limited rating of 2 A @ 30 VDC, resistive; non-power limited rating of 0.5 A @ 125 VAC, resistive 4098-9822, LED Annunciation Relay: Activates when base LED is on steady, indicating local alarm or trouble DPDT contacts for resistive/suppressed loads, power limited rating of 2 A @ 28 VDC; non-power limited rating of 1/2 A @ 120 VAC, (requires external 24 VDC coil power) 4098-9832, Adapter plate: Required for surface or semi-flush mounting to 4" square electrical box and for surface mounting to 4" octagonal box Can be used for cosmetic retrofitting to existing 6-3/8" diameter base product 2098-9808, Remote red LED Alarm Indicator: Mounts on single gang box (shown in illustration to right) ARM Simplex Dstrintk TrueAlarm sensor bases contain integral addressable electronics that constantly monitor the status of the detachable photoelectric or heat sensors. Each sensor's output is digitized and transmitted to the system fire alarm control panel every four seconds. Since TrueAlarm sensors use the same base, different sensor types can be easily interchanged to meet specific location requirements. This feature also allows intentional sensor substitution during building construction. When conditions are temporarily dusty, instead of covering the smoke sensors (causing them to be disabled), heat sensors may be installed without reprogramming the control panel. Although the control panel will indicate an incorrect sensor type, the heat sensor will operate at a default sensitivity providing heat detection for building protection at that location. 'IvuourILurly rceiererie Electrical Box Requirements: (boxes are by others) Withoiitreiayinthe box: 4" octagonal or 4" square, 1-1/2" deep; single gang, 2" deep Will relay in the box :4" octagonal or 4" square, 1-1/2" deep, with 1-1/2" extension ring 4(102mm) Square Box 4 (102 mm) Octagonal Box Surface mount reference-... -7 I 1-1/2" (38 mm)' minimum box depth Flush mount reference, mount even with final surface, or with up to 1/4' (6.4 mm) maximum recess 2098-9737 Supervised Relay 4098-9822 Relay (mounts (mounts in base electrical box or in base electrical box) remotely) FRel'ay S,:e') -1/2" X 3.75 in3)(64 mm X 38 mm X 25.4 mm) 098-9860 Supervised Relay(mounts in base electrical box or remotely; 2-3/OX 1-1/4" X 11/32 (1 in3 ) (60.4 mm X 31.8 mm X 8.6 mm) NOTE: Review total wire count, wire size, and accessories being wired to determine required box volume. H 6-3/8" (162 mm) 4098-9832 Adapter Plate, required for 1/4" mounting to surface mounted boxes (6.4 mm) and 4" square flush box H 4-7/8" (124 mm) 15/16" I (24 mm) TrueAlarm Bases 4098-9780, 4098-9789, 4098-9791, & 4098-9792 S4098-0019-23 8/2017 T2-3/8" (60 mm) T 2-3/8" (60 mm) TrueAlarm Sensors Sealed against rear air flow entry Interchangeable mounting EMI/RFI shielded electronics Heat sensors: Selectable rate compensated, fixed temperature sensing with or without rate-of-rise operation Rated spacing distance between sensors: Fixed Temp. UL & ULC FM Spacing, Either Fixed Setting Spacing I Temperature Setting 135° F /190° F* 60 ft x 60 ft 20 ft x 20 it (6.1 m) for fixed (57.2°C / 88° C) (18.3 m) temperature only; RTI = Quick 50 ft x 50 ft(15.2 m) for fixed 155° F 40 ft x 40 ft - temperature with either (68° C) (12.2 m) rate-of-rise selection; RTI = Ultra Fast *Note: 190° F (88° C) ratings apply only to the 4098-9734 sensor Smoke Sensors: Photoelectric technology sensing 3600 smoke entry for optimum response r Built-in insect screens ..- 4098-9714 Phntnitrk Snsnr TrueAlarm photoelectric sensors use a stable, pulsed infrared LED light source and a silicon photodiode receiver to provide consistent and accurate low power smoke sensing. Seven levels of sensitivity are available for each individual sensor, ranging from 0.2% to 3.7% per foot of smoke obscuration. Sensitivities of 0.2%, 0.5%, and 1% are for special applications in clean areas. Standard sensitivities are 1.5%, 2.0%, 2.5%, 3.0%, and 3.7%. Application type and sensitivity are selected and then monitored at the fire alarm control panel.* The sensor head design provides 360° smoke entry for optimum response to smoke from any direction. Due to its photoelectric operation, air velocity is not normally a factor, except for impact on area smoke flow. 7 H 4-7/8° (124 mm) LED status indicator 2-1/8° (54 mm) 4098-9714 Photoelectric Sensor with Base 4fl98=97and 4098-974 Hat Snsnr TrueAlarm heat sensors are self-restoring and provide rate compensated, fixed temperature sensing, selectable with or without rate-of-rise temperature sensing. Due to its small thermal mass, the sensor accurately and quickly measures the local temperature for analysis at the fire alarm control panel. Rate-of-rise temperature detection is selectable at the control panel for either 15° F (8.3° C) or 20° F (11.1°C) per minute. Fixed temperature sensing is independent of rate-of-rise sensing and programmable to operate at 135° F (57.2° C)or 155° F (68° C). The 4098-9734 sensor provides an additional 190° F (88° C) set point. In a slow developing fire, the temperature may not increase rapidly enough to operate the rate-of-rise feature. However, an alarm will be initiated when the temperature reaches its rated fixed temperature setting. TrueAlarm heat sensors can be programmed as a utility device to monitor for temperature extremes in the range from 32° F to 155° F (0° C to 68° C). This feature can provide freeze warnings or alert to I{VAC system problems. Refer to specific panels for availability. 4098-9733 Heat Sensor with Base 4098-9734 High Temperature Heat Sensor with Base WARNING: In most fires, hazardous levels of smoke and toxic gas can build up before a heat detection device would initiate an alarm. In cases where Life Safety is a factor, the use of smoke detection is highly recommended. Sensor locations should be determined only after careful consideration of the physical layout and contents of the area to be protected. Refer to NFPA 72, the National Fire Alarm and Signaling Code. On smooth ceilings, smoke sensor spacing of 30 ft (9.1 m) may be used as a guide.* * For detailed application information including sensitivity selection, refer to Installation Instructions 574-709. C S4098-0019-23 8/2017 TrueAlarm Analog Sensing Product Selection Chart TrueAlarm Sensor Bases (for use with Sensors 4098-9714 and 4098-9733) (Refer to Application Manual 574-709 and Installation Instructions 574-707 for additional information) Modem - Color Description Compatibility Mounting Requirements C 4098-9792 White Standard Sensor Base No options 4" octagonal or 4" square box, 1-1/2" mm. depth: or single gang box, 2" 4098-9776 Black mm. depth 4098-9789 White Sensor Base with connections for Remote LED Alarm Indicator or 2098-9808 Remote Alarm Indicator or 4" octagonal or 4" square box 4098-9789 IND White Unsupervised Relay 4098-9822 Unsupervised Relay Note: Box depth requirements - 4098-9775 Black depend on total wire count and wire size, refer to accessories 4-Wire Sensor Supervised Relay 2098-9737 Supervised Remote Relay 40989791** White Base with connections for LED list below for reference. 2098-9808 Remote Alarm Indicator or Indicator or Unsupervised Relay 4098-9822 Unsupervised Relay ** NOTE: 4098-9791 and 4098- 9780 are NOT compatible with the 2120 CDT 2-Wire Sensor Supervised Relay U98-9860 Supervised Remote Relay 2098-9808 Remote Alarm Indicator or 4098_9780** White Base with connections for LED Indicator or Unsupervised Relay 4098-9822 Unsupervised Relay TrueAlarm Sensors Model* Model* i 4098-9714' -- ... White Description Photoelectric Smoke Sensor Sensor Compatibility Bases 4098-9775, 4098-9776, 4098-9792, 4098-9789, 4098-9791, and 4098-9780 Mounting Requirements Refer to base requirements S TrueAlarm Sensor/Base Accessories Model Description Compatibility Mounting Requirements 2098-9737 Supervised Relay, mounts remote or in base For use with 4098-9791 base Remote Mounting requires 4" octagonal or electrical box 4" square box, 1-1/2" minimum depth Base Mounting requires 4" octagonal box, 2- Supervised Relay, mounts remote or in base 4098-9860 electrical box For use with 4098-9780 base 1/8" deep with 1-1/2" extension ring 2098-9808 Remote Red LED Alarm Indicator on single gang Bases 4098-9789, 4098-9791, and 4098- Single gang box, 1-1/2" minimum depth stainless steel plate 9780 4098-9822 Unsupervised Relay, tracks base LED status: Bases 4098-9789, 4098-9791, and 4098- 4" octagonal box, 2-1/8" deep with 1-1/2" Note: Mounts only in base electrical box 9780 extension ring Bases 4098-9792, 4098-9789, Required for surface or semi-flush mounted 4" 4098-9832 Adapter Plate 4098-9791, and 4098-9780 square box and for surface mounted 4" octagonal box * Note: Model numbers ending in IND are assembled in India. General Operating Specifications Communications and Sensor Supervisory Power IDNet or MAPNET II communications, auto-selected, 1 address per base Communications Connections Screw terminals for in/out wiring, 18 to 14 AWG (0.82 mm2 to 2.08 mm2) Remote LED Alarm Indicator Current 1 mA typical, no impact to alarm current Remote LED Alarm Indicator and Relay Connections Color coded wire leads, 18 AWG (0.82mm2 ) UL Listed Operating Temperature Range 32" to 100" F (0" to 38" C) with 4098-9733 Heat Sensor Operating Temperature with 4098-9714 Smoke Sensor Range With 4098-9734 Heat Sensor 32" to 122" F (0" to 50" C) 15" to 122" F (-9" to 50" C) 32" to 150" F (0" to 66" C) Storage Temperature Range 0" F to 140" F (-18" C to 60" C) Humidity Range 10 to 95% RH 4098-9714 Smoke Sensor Air Velocity Rating 0-4000 ft/min (0-1220 rn/mm) Housing Color Frost White or Black 4098-9791 Base With Supervised Remote Relay 2098-9737 (see page 2 for contact ratings) Externally Supplied Relay Coil Voltage 18-32 VDC (nominal 24 VDC) Supervisory Current 270 pA, from 24 VDC supply Alarm Current with 2098-9737 Relay 28 mA, from 24 VDC supply 4098-9780 Base With Supervised Remote Relay 4098-9860 (see page 2 for contact ratings) Power I Supplied from communications 4098-9822 Unsupervised Relay, Requirements for Bases 4098-9789. 4098-9791, and 4098-9780 (see page 2 for contact ratings) SIMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association ('NFPA). U.SiMP11EX Westminster, MA •01441-0001 USA S4098-0019-23 8/2017 wvw.simp1ex-fire.com 0 2017 Johnson Controls. All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice. ®Sim pIEX S UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* TrueAlert Multi-Candela Notification Appliances Visible Notification Appliances with Synchronized Flash; Non-Addressable, SmartSync Operation Compatible Ii!I(*I Visible only (VIO) 24 VDC notification appliances with high output xenon strobe, available for wall or ceiling mount: Intensity is selectable as 15, 30, 75, or 110 candela with visible selection jumper, secured behind strobe housing Operation is compatible with ADA requirements (refer to important installation information on page 3) Polarized input allows connection to compatible reverse polarity, supervised notification appliance circuit (NAC) Regulated circuit design ensures consistent flash output and provides controlled inrush current Rugged, high impact, flame retardant thermoplastic housings are available in red or white with clear lens . Listed to UL 1971 and TJLC S526 Wall Mount Strobes FIRE Strobes provide synchronized flash for use with: Simplex® fire alarm control panels with NACs selected to provide strobe synchronization or SmartSync two-wire control I Usrintinn Ceiling Mount Strobes . 4009 IDNet NAC Extenders . . Separate strobe Synchronization Modules that are available for Class B or Class A operation Separate SmartSync Control Modules (SCMs) that provide Class B or Class A output from conventional NAC inputs Strobe housings provides flexible, easy, and convenient semi-flush or surface wall mounting: Rear of housing does not extend into box Wall mount strobes easily mount to single gang, double gang, or 4-inch square outlet box Ceiling mount strobes mount to single gang boxes Wall mount strobe features: Wiring terminals are accessible from the front of the housing providing easy access for installation, inspection, and testing Covers are available separately to convert housing color Optional adapters and wire guards: Wall mount strobe adapters are available to cover surface mounted electrical boxes and to adapt to Simplex 2975-9145 boxes UL listed red wire guards are available for wall or ceiling mount strobes* S * Refer to page 2 for guard listing. This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7125-0026:316 for allowable values and/or conditions concerning material presented in this document. Refer to page 2 for listing status of wire guards. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. Multi-Candela TrueAlert synchronized strobes provide convenient installation to standard electrical boxes. The enclosure designs are both impact and vandal resistant and provide a convenient strobe intensity selection. Since each model can be selected for intensity output, on-site model inventory is minimized and changes encountered during construction can be easily accommodated. Wall mount strobe housings are a one-piece assembly (including lens) that mounts to a single or double gang, or 4" square standard electrical box. The cover can be quickly removed (a tool is required) and covers are available separately for color conversion. Ceiling mount strobes install using standard single gang electrical boxes. Color choice is determined by model number. During installation, a selection plug at the back of the housing determines the desired strobe intensity. An attached flag with black letters on a highly visible yellow background allows the selected intensity to be seen at the side of the strobe lens. U71 TTT1 FF11!1 ti Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm Code (NFPA 72), ANSI A117.1; the appropriate model building code: BOCA, ICBO, or SBCCI; and the application guidelines of the Americans with Disabilities Act (ADA). S4906-0001-5 11/2014 Mllelllilelili FT IT1I ET1.T1II.1! I I(*I Multiple Strobes. When multiple strobes and their SmartSync two-wire control is available from: reflections can be seen from one location, synchronized • 4006, 4007ES Hybrid, 4008, 4010, 4010ES, 4100ES, flashes reduce the probability of photo-sensitive reactions and 4100U Fire Alarm Control Panels (refer to as well as the annoyance and possible distraction of individual product data sheets for more information) random flashing. These multi-candela strobes are . 4009 IDNet NAC Extenders (refer to data sheet synchronized over a two-wire circuit when connected to s4009-0002) compatible NACs, to compatible Synchronized Flash • SmartSync Control Module (SCM) Model 4905-9938 Modules, or to SmartSync Control Modules. (refer to data sheet S4905-0003) Additional SmartSync compatible notification Some applications desire the audible notification appliances include separate horns and combination appliances to be capable of being silenced before the horn/strobe notification appliances. alarm condition is reset (on-until-silenced) while the visible notification appliances are kept activated until the alarm condition is reset (on-until-reset). SmartSync operation mode provides this function using a single. circuit (two-wire operation). cIutt Sclrtir Multi-Candela Visible Notification Appliances (Strobes) Model Mounting Housing Color I "FIRE" Lettering I Description 4906-9101 Wall Red I White I Multi-candela strobe with intensity selectable as: I 15, 30, 75, or 110 candela; synchronized flash rate; 4906-9103 White I I Red 4906-9102 cCë5 ng Red White I SmartSync two-wire control compatible 49069104 White Red Wall Mount Strobe Adapters Model Description Dimensions 4905-9937 Red I Surface Mount Adapter Skirt; use to cover 1-1/2" (38 mm) 5-3/8" H x 5-1/4" W 1-5/8" D 4905-9940 White deep surface mounted boxes (136 mm 133 mmx4l mm) Total depth with strobe = 4-3/8" (111 mm) 4905-9931 Red Adapter Plate for mounting to Simplex 2975-9145 box (typically for 8-5/16" x 5-3/4" x 0.060" Thick _ retrofit, may be mounted vertical or horizontal) (211 mm x 146 mm x 1.5 mm) 2975-9145 Red Mounting Box, requires Adapter Plate 4905-9931 7-7/8" x 5-1/8" x 2-3/4" D (200 mm x 130 mm x 70 mm) Ceiling Mount Strobe Adapter Model Description Dimensions 4905-9910 Surface Mount Adapter Plate; zinc plated; required for mounting to 4-7/8" x 3-1/8" x 0.060" D handy box; not needed when using 4905-9926 guard (124 mm x 79 mm x 1.5) Synchronization Modules (refer to data sheet S4905-0003 for additional information) Model Description Dimensions 4905-9914 Class B Synchronized Flash Module; epoxy encapsulated with 1-3/8" x 2-7/16" x 13/16" in/out 18 AWG (0.82 mm2) wire leads, rated for 2 A NAC, (35 mm x 62 mm x 20 mm) 4905-9922 Class A requires 5 mA for power 4905-9938 SmartSync Control Module with Class B or Class A output; mounts in 4" x 4-1/8" x 1-1/4" D 4" (102 mm) square box (102 mm x 105 mm x 32 mm) Replacement Covers and Guards Model Description Dimensions 4905-9992 Red cover with white "FIRE" lettering I 5-1/8" H x 5" W 1-1/2" D For Wall mount strobes 4905-9993 White cover with red "FIRE" lettering (130 mm x 127 mm x 38 mm) 49059961* Wall mount 6-1/16" H x 6-1/16" W 3-1/8" 0 Red wire guard with mounting plate, compatible with I semi-flush or surface mounted boxes (154 mm x 154 mm x 79 mm) 49059926* Ceiling mount 6-1/8" x 4-3/8" x 2-7/8" deep (156 mm x 111 mm x 73 mm) * UL listed by Space Age Electronics Inc IIRlIIIIi§FP%1]E11. Wall Mount or Ceiling Mount, Common Specifications Rated Voltage Range Regulated 24 VDC; see Note I below Flash Rate 1 Hz Synchronized NAC Loading Up to 35 synchronized strobes maximum per NAC Temperature Range 32° to 122° F (0° to 50° C) Humidity Range 10% to 93%, non-condensing at 100° F (38° C) Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2); two wires per terminal for in/out wiring Housing Dimensions (with lens) 5-1/8" H x 5" W 2-3/4" D (130 mm x 127 mm x 70 mm) Wall Maximum RMS Current Rating per Strobe Setting (see Note 2 below) 15 Cd 30 Cd 75 Cd 110 Cd 60 mA 94 mA 186 mA 252 mA Moun tReference RMS Currents 18 VDC at other voltages 24 VDC 53 mA 84 mA 165 mA 224 mA 40 mA 63 mA 124 mA 168 mA Housing Dimensions (with lens) 4-3/4" Lx 2-5/16" W 2-5/8" D (121 mm x75mm x 67 mm) - , CelIIng/ Mount Maximum RMS Current Rating per Strobe Setting (see Note 2 below) 15 Cd 30 Cd 75 Cd 110 Cd 75 mA 125 mA 233 mA 316 mA Reference RMS Currents 18 VDC at other voltages 24 VDC 67 mA 111 mA 207 mA 281 mA 50 mA 83 mA 155 mA 211 mA NOTES: "Regulated 24 VDC" refers to the voltage range of 16 to 33 VDC per UL Standard 1971, Signaling Devices for the Hearing Impaired. This voltage range is the absolute operating range. Operation outside of this range may cause permanent damage to the strobe. Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. The maximum RMS current listed is the device nameplate rating. Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage. (RMS is root mean square and refers to the effective value of a varying current waveform.) Installation Reference, Surface or Semi-Flush Wall Mounting (JTh çTh çTh Mounting is compatible with ( ( single gang, double gang, and ____________ 1-1/2" (38 mm) deep, by others ____________ 4" (102 mm) square boxes, 1=0 0=0 up Wiring access hole Wiring terminals- Mounting Holes: Single gang (2) Double gang (3) Transparent housing Single gang (2) Dou ble gang (3) and lens assembly Intensity selection 110 S plug, accessible only In from rear of ho 75 usi Is ng; [F [1 [rRD[ factory setting is 15 Cd Removable cover Strobe intensity (tool required) viewing slot 3 IMPORTANT! WALL MOUNT INSTALLATION HEIGHT REFERENCE Bottom of lens is either even with, or slightly box outline above bottom of compatible boxes NFPA 72 requires 80" (2.03 m) that the entire lens minimum be not less than 80" and not greater than 96" above the finished floor S4906-0001-5 11/2014 Ceiling Mount Strobe Installation Reference Single gang box (Wiremold V5744S) 2-1/4' (57 mm) deep, supplied by others Handy box, 1-1/2' (38 mm) deep (RACO 650 or equal) or single gang box, 2-1/2" (64 mm) deep (RACO 519 or equal) supplied by others Also can be attached to boxes mounted to drop ceiling T-bar with clips (ERICO No. 512 or equal) I 4905-9910 Adapter Plate, required for 0 0 Oj( surface mount with handy box unless using the 4905-9926 wire guard ' nt strobe 905-9926 wire guard ing plate ------------------ Strobe intensity viewing slot ntensity selection plug, 3ccessible only from rear of lens: lousing; factory setting is 15 cd Wall Mount Installation Reference; Adapter Plate, Guard, and Adapter Skirt S Fol 4905-9931 Adapter Plate 45 °Lc non2 4905-9931 Adapter Plate 4905-9961 Optional Wire Guard (shown here for reference only, can be used on other mounting options) Surface Mounting Reference with Optional Adapter Skirt and Optional Wire Guard Surface mount conduit and box shown for reference eep Optional 4905-9961 Wire Guard Strobe t I_ Optional Surface Mount Adapter Skirt, 1-1/2" deep: 4905-9937, Red; 4905-9940, White (conduit knockouts are provided on all four sides) TYCO, SIMPLEX and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm and Signaling Code are registered trademarks ojthe National Fire Protection Association (NFPA). JI.SiMpirX Tyco Fire Protection Products Westminster, MA • 01441-0001 USA S4906-0001-511/2014 www.simplex-fire.com 0 2014 Tyco Fire Protection Products. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. BuSimplEx TrueAlert Multi-Candela Notification Appliances UL, ULC, CSFM Listed; FM Approved; SmartSync Operation Audible/Visible Notification MEA (NYC) Acceptance* with Horn and Synchronized Flash, Non-Addressable S I(!I*I Audible/visible (AN) notification appliances with efficient electronic horn and high output xenon strobe, available for wall or ceiling mount Operation is compatible with ADA requirements (refer to important installation information on page 3) Rugged, high impact, flame retardant thermoplastic housings are available in red or white with clear lens Operates over a two-wire SmartSync circuit to provide: Horns that are controlled separately from strobes on the same two-wire circuit "On-until-silenced" and "on-until-reset" operation on the same two-wire pair SmartSync horn activation of Temporal pattern, March Time pattern (at 60 BPM), or on continuously Strobe appliances on the same circuit operating at a synchronized 1 Hz flash rate Class B operation requires connection to a compatible SmartSync NAC or to SmartSync Control Module• (SCM) 4905-9938 Class A operation when connected to the 4905-9938 SCM or with 4100U series fire alarm control panel NACs Wall mount ANs features: Wiring terminals are accessible from the front of the housing providing easy access for installation, inspection, and testing Covers are available separately to convert housing color Available UL listed sound damper for locations requiring attenuation of 5 to 6 dBA (stairwells, small rooms, highly reverberant areas, etc.) Optional adapters and wire guards: Wall mount AN adapters are available to cover surface mounted electrical boxes and to adapt to Simplex® 2975-9145 boxes UL listed red wire guards are available for wall or ceiling mount A/Vs Visible notification appliance (strobe): 24 VDC xenon strobe; intensity is selectable as 15, 30, 75, or 110 candela with visible selection jumper secured behind strobe housing UL listed to Standard 1971 Regulated circuit design ensures consistent flash output and provides controlled inrush current Audible notification appliance (horn): Low current, 24 VDC electronic horn with harmonically rich sound output suitable for either steady or coded operation (Temporal or 60 BPM March Time pattern) UL listed to Standard 464 F I R E --, vAv1lrt uryA flpsrintinn Multi-Candela TrueAlert ANs with horn and synchronized strobe provide convenient installation to standard electrical boxes. The enclosure designs are both impact and vandal resistant and provide a convenient strobe intensity selection. Since each model can be selected for strobe intensity output, on-site model inventory is minimized and changes encountered during construction can be easily accommodated. Wall mount AN housings are a one-piece assembly (including lens) that mounts to a single or double gang, or 4" square standard electrical box. The cover can be quickly removed (a tool is required) and covers are available separately for color conversion. Ceiling mount A/Vs install using standard 4" electrical boxes. Color choice is determined by model number. During installation, a selection plug at the back of the housing determines the desired strobe intensity. An attached flag with black letters on a highly visible yellow background allows the selected intensity to be seen at the side of the strobe lens. * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7125-0026:317 for allowable values and/or conditions concerning material presented in this document. Accepted for use - City of New York Department of Buildings - MEA35-93E. Refer to page 2 for listing status of wire guards. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products, S4906-0002-6 11/2014 Firm rr7i F.2flTb rThTA'11745U71I Proper selection of visible notification is dependent on SmartSync operation mode allows a two-wire circuit to occupancy, location, local codes, and proper applications provide the ability to activate both the horn and strobe on of: the National Fire Alarm Code (NFPA 72), ANSI the same NAC and then allow the horn to be silenced A117.1; the appropriate model building code: BOCA, while the strobe remains flashing. The horn operates as ICBO, or SBCCI; and the application guidelines of the "on-until-silenced" while the strobe operation is Americans with Disabilities Act (ADA). "on-until-reset." U'1iT i7Th FZV IiT1!1 FThiT'flh1IT1Ii.i'i *-i Multiple Strobes. When multiple strobes and their 4006, 4007ES Hybrid, 4008, 4010, 4010ES, 4I00ES, reflections can be seen from one location, synchronized and 4100U Fire Alarm Control Panels (refer to flashes reduce the probability of photo-sensitive reactions individual product data sheets for more information) as well as the annoyance and possible distraction of 4009 IDNet NAC Extender (refer to data sheet random flashing. The multi-candela strobes of these A/Vs S4009-0002) are synchronized by the controlling SmartSync operation SmartSync Control Module (SCM) 4905-9938 (refer to NAC. data sheet S4905-0003) Additional SmartSync compatible notification appliances include separate horns and combination horn/strobe notification appliances. I7 r 1r1 rtrim Multi-Candela A/Vs Model Mounting Housing Color "FIRE" Lettering Description 4906-9127 Wall Red White 4906-9129 White Red Horn with Multi-Candela Strobe; strobe intensity selectable as: 15, 30, 75, or 110 candela; operates with SmartSync two-wire 4906-9128 Red White c. Ceiling control (4906-9130 White Red Wall Mount AN Accessories Model Description Dimensions 4905-9937 Red I Surface Mount Adapter Skirt; use to cover 1-1/2" (38 mm) deep 5-3/8" H x 5-1/4" W x 1-5/8" D 4905-9940 White surface mounted boxes (136 mm x 133 mm x 41 mm) depth with strobe = 4-3/8" (111 mm) 4905-9931 Red Adapter Plate for mounting to Simplex 2975-9145 box (typically for retrofit, may be mounted vertical or horizontal) 8-5/16" x 5-3/4" x 0.060" Thick (211 mm x 146 mm x 1.5 mm) 2975-9145 Red Mounting Box, requires Adapter Plate 4905-9931 7-7/8" x 5-1/8" x 2-3/4" D (200 mm_x_130_mm_x_70_mm) Optional Sound Damper; package of 20; field installed adhesive backed 4905-9838 horn output attenuator; reduces output 5 to 6 dBA 1-3/4" Diameter (44.5 mm) NOTE: After Sound Damper installation, measure sound level to ensure with 0.31" (8 mm) sound opening comoliance with anolicable code reauirements SmartSync Control Module Model Description Dimensions 4905-9938 SmartSync Control Module with Class B or Class A output; mounts in 4" 4" x 4-1/8" x 1-1/4" D (102 mm) square box; refer to data sheet S4905-0003 for details (102 mm x 105 mm x 32 mm) Replacement Covers for Wall Mount A/Vs Model Description 4905-9994 Red cover with white "FIRE" lettering 4905-9995 White cover with red "FIRE" lettering and Ceiling Mount AN Adapter Wire Guards Model Description 49059961* Wall mount red wire guard with mounting plate, compatible with semi-flush or surface mounted boxes Red Wire Guard for mounting to flush mounted electrical box 49059927* S 4905-9928' Ceiling Mount Red Adapter Plate, required to mount guard to surface mounted electrical box White Surface Mount Adapter Box Extension, use to cover 4905-9915 Red 4905-9916 1 1-1/2" deep surface mounted boxes * UL listed by Space Age Electronics Inc. 2 Dimensions 5-118"Hx5"Wx1-1/2"D (130 mm x 127 mm x 38 mm) Dimensions 6-1/16" Hx6-1/16"Wx3-118" D (154 mm x 154 mm x 79 mm) 8-1/2"x6-1/8" x3" (216 mm x 156 mm x 76 mm) 9" x 7" (229 mm x 178 mm) 4-3/4" x 6-7/8" x 1-1/2" deep, (121 mm x 175 mm x 38 mm) S4906-0002-6 11/2014 Removable cover (tool required) AN S pec if ic ations Wall Mount or Ceiling Mount, Common Specifications Rated Voltage Range UL Listed Rating ULC Listed Rating Regulated 24 DC; see Note 1 below 20 VDC to 30 VDC per ULC S526-M878 Flash Rate and Synchronized NAC Loading 1 Hz; with up to 35 synchronized strobes maximum per NAC Environmental; Temperature and Humidity 32° to 122° F (0° to 50° C); 10% to 93%, non-condensing at 100° F (38° C) Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2); two wires per terminal for in/out wiring Horn Output Characteristics 2400 to 3700 Hz sweep, modulated at 120 Hz rate Horn Output Voltage Ratings Sound Type (see Note 2) 16 VDC 24 VDC 33 VDC Steady Coded Steady Coded Steady Coded @ lOft (3 m) UL 464 Reverberant Chamber 86 dBA 82 dBA 88 dBA 84 dBA 90 dBA 86 dBA (see Note 2) Anechoic Chamber 92 dBA 91 dBA 94 dBA 95 dBA 96 dBA 96 dBA Housing Dimensions (with lens) 5-1/8" H x 5" W 2-3/4" D (130 mm x 127 mm x 70 mm) Maximum RMS Current Rating per Strobe Setting (see Note 3 below) 15 Cd 30 Cd 75 Cd 110 Cd 75 mA 116 mA 221 mA 285 mA Reference RMS Currents 18 VDC at other voltages 24 VDC 67 mA 103 mA 196 mA 253 mA 50 mA 77 mA 147 mA 190 mA Housing Dimensions (with lens) 4-3/4 L" x 6-7/8" W 2-5/8" D (121 mm x 175 mm x 67 mm) Vount Maximum RMS Current Rating per Strobe Setting (see Note 3 below) 15 Cd 30 Cd 75 Cd 110 Cd 86 mA 132 mA 250 mA 320 mA Reference RMS Currents 18 VDC at other voltages 24 VDC 76 mA 117 mA 222 mA 284 mA 57 mA 88 mA 167 mA 213 mA NOTES: "Regulated 24 DC" refers to the voltage range of 16 to 33 VDC per UL Standard 1971, Signaling Devices for the Hearing Impaired. This voltage range is the absolute operating range. Operation outside of this range may cause permanent damage to the appliance. Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. Coded values are typical of the output measured with a Temporal coded or a March Time coded pulse and with a sound level meter reading on a "fast" setting. Under the same test conditions, coded horn output "peak" sound level readings are typically 4 dBA higher. Anechoic horn output ratings are typically more representative of actual installed sound output. Currents are with horn on steady. The maximum RMS current listed is the device nameplate rating. Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage. (RMS is root mean square and refers to the effective value of a varying current waveform.) Installation Reference, Surface or Semi-Flush Mounting (fl Mounting Holes: j 4" square (4) Single gang (2) Double Double Transparent housing gang (3) and lens assembly Intensity selection plug, accessible only from rear of housing; ( I 15 factory setting is 15 cd Strobe intensity viewing slot 3 IMPORTANT! WALL MOUNT INSTALLATION HEIGHT REFERENCE Bottom of lens is either even with, or slightly r -Electrical above bottom box outline of compatible \ ri boxes I ___T NFPA 72 requires 80" (2.03 m) that the entire lens minimum be not less than 80" and not greater than 96" above the finished floor S4906-0002-6 11/2014 Mounting is compatible with single gang, double gang, and 4(102mm) square boxes, 1-1/2" (38 mm) deep, by others Optional 4905-9838 Sound Damper, field attached to attenuate sound 5 to 6 dBA Wiring access hole 0 Wiring terminals for SmartSync operation S 145 4905-9931 Adapter Plate 4905-9961 Optional Wire Guard (shown here for reference only, 4905-9931 Adapter Plate can be used on other mounting options) Ceiling Mount AN and Guard Installation Reference S Ceiling reference, 4" (102 mm) square box, surface mounted box 1-1/2" (38 mm) minimum depth CC: 0, Ceiling reference, ) -f,' flush mounted boxy Optional 4905-9915/-9916 Adapter, recommended for surface mounted box ,_- Wiring terminals are p5 located behind the housing : :::~ F LMFDa E Optional 4905-9928 Adapter Plate, required for surface mounted electrical box Four mounting clamps included, two each side - Optional 4905-9927 Red Wire Guard End View I Strobe intensity viewing slot Intensity selection plug, accessible only from rear of lens housing; factory setting is 15 cd -------------------------------------- Wall Mount Installation Reference; Adapter Plate, Guard, and Adapter Skirt Surface Mounting Reference with Optional Adapter Skirt and Optional Wire Guard Surface mount conduit and box shown for reference 4" (102 mm) square I box profile, 1-1/2" I (38 mm) deep Optional 4905-9961 Wire Guard =7 1 Optional Surface Mount Adapter Skirt, 1-1/2" deep: 4905-9937, Red; 4905-9940, White (conduit knockouts are provided on all four sides) TYCO, SIMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited NFPA 72 and National Fire Alarm and Signaling Code are registered trademarks of the National Fire Protection Association (NFPA). 5 Si rn I EX Tyco Fire Protection Products• Westminster, MA 01441-0001 • USA S4906-0002-6 11/2014 www.simplex-ffre.com 0 2014 Tyco Fire Protection Products. All rights reserved. All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. Extension Rod Applications --------i —tE1 LJ . Dual Voltage (rear vlew shown) At II IM uftrl YC,P0LJr I - 1 — -' I u — RSG Security 2700 Junipero Ave Signal Hill CA, 90755 www.rsgsecurity.com Tel: (562) 529-5100 Fax: (562) 529-5102 DH( )FB DH ( )FPC (DH(,)SPC DH( )FDBR DH( )GPC1 DH( )RPC (Brass Plate (Flush Mount) (Surface Mount) (Ground Mount) (Recessed) Description: DH series fire door holders are constructed of the finest materials and workmanship available. The door holder is made of durable die-cast metal and offered in a high luster powdercoat finish. Other features include standard dual voltage ac or do inputs of 12 & 24V, 24 & 120V and 24 & 220V models. While reducing stocking requirements, model 24120 draws a mere .020 ma. 0 24VDC lowenng overall job costs. (In large installations the cost savings can be substantial). jgpher features: single or double coil floor mounting, surface mounting and direct wall mounting. No brackets are required. The H series door holder offers a new installation technique using an adhesive template assuring alignment without secondary adjustments. Accessories include extension and misalignment rods (various lengths) enabling parallelism between door and wall at distances greater than 12 inches and misalignment over 4 inches. Aiding in installation is the aircraft quality OH drill that reduces installation time and provides a near perfect alignment of catch- plate and armature - again, lowering overall installation costs. Basic units offer superior holding force and low residual magnetism. Models 1224 and 24120 can operate at higher listed voltages producing holding forces in excess of iQOibs, (45.3kg.) For special applications, OPTIONAL FEATURES OWDERCOATED FINISHES "WEXTENSION AND MISALIGNMENT RODS SURFACE MOUNT BACK BOX TIME SAVING DRILL FIXTURE (FOR MOUNTING CATCH PLATE) STANDARD FEATURES VERY LOW CURRENT DRAW DUAL VOLTAGE INPUTS TERMINAL BLOCK CONNECTIONS MADE IN HIGH HOLDING FORCE AMERICA LOW RESIDUAL MAGNETISM MOUNTING HARDWARE & INSTRUCTIONS ORDERING INFORMATION: OH Door Holder F Flush Mount S Surface Mount R Recessed G Ground Mount PC Powdercoat Chrome Brass Plated 1 Single Coil 2 Double Coil NOTE: #2 indicates double coil ground mount model. Example: OH (24 20) Door Holder I Mode IIVoltage 1224, 24120,24220 (l} Surfacer Fush, Ground, Recessed Powdercoated Finish Chrome, Brass, DBR (Dark Bronze) Coils 1,2 For ground mount models . DI-IE1 PC I Inch extension chrome DHE1 B I inch extension brass DI-IE1.5PC 1.5 Inch extension chrome DHE1,58 1.5 inch extension brass DHE213C 2 Inch extension chrome DHE2B 2 inch extension brass DI-IE3PC 3 Inch extension chrome DHE313 3 Inch extension brass DIIEAPC 4 inch adjustable extension chrome DHEAB 4 inch adjustable extension brass Hardware: DHSBPC Swwel base chrome DHSBB Swivel base brass DRCPC Catch plate chrome DHCPB Catch plate brass DI-IBBPC Surface back box chrome 011888 Surface back box brass 011W Extension wrenches OI-IDF Drilling fixture Extension Wrenches Magnetic Door Holder I 1N* 1 Installation Tools: DHDF (drill fixture) PERFORMANCE DATA.- MODEL VOLTAGE DC/mA AC/MA TERMINALS LB. KG 1224 12V 40 38 C&L 30 16 24V 40 36 C&H 30 13.6 24120 24V 20 19 C&L 40 181 120V 20 C&H 35 158 24220 24V 20 19 C&L 20 1 9.0 _C&H _22 98 I NOTE: Holding forces listed in above table corresponds with shaded values, non shaded values are slighty less, MODEL VOLTAGE D/rnA Ac/MA Terminals LB. KG. 1224 24V 85 81 C&L 75 34.0 24120 120V — .100 C&L 110 49,8 HIGH HOLDING FORCE/SPECIAL APPUCATIONS: To obtain performance values in table above apply high listed voltage to low voltage terminals (C & L). NOTE: This configuration can only be applied to models 1224 & 24120. ACCESSORIES Extensions Surface MoIrntinB: Extension rods DHHBB (back box) O1 HE -- -- -E- kr i- 4.le' -VI Coil! b LA --- ___ - ri...i —I L___-__ 1F 13 iti T1 if,,'-I.' — — h WE" I:Uih.'l ACCESSORIES: Extensions: Door Holder Swivel base I- -I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL . FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:0214 Page 1 of 1 CATEGORY: 7300-- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: jgoyette@tycoint.com DESIGN: Models* 4009-9001, 4009-9002, 4009-9101, 4009-9102,14009-9201, 4009-9301, 4009-9401 Notification Appliance Circuit (NAC) Power Extenders. Refer to listee's data sheet for detailed product description and operational considerations. Unit components: 565-594 Power Supply 565-569 Style Y Signal Card 565-358 Voice Controller Card 562-907 Amplifier Board 565-388 Style Z Signal Card 4009-9807 NAC Option Card 4009-9810 Fiber Receiver 40909105,*9107 Fiber Transmitter 4009-9809 IDNet Repeater 4009-9808 Class A Adaptor 4009-9803-98044 Circuit NAC Card 4905-9929 Isolator Module 4009-9806 Earth Detect Module *40039803 Remote Microphone Module RATING: INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. The NAC must be fully supervised and must have the secondary power supply capable of operating the system for at least 24 hours (battery standby) in the normal condition and followed by not less than 5 minutes of alarm as required by code. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as power extender units for use with listee's separately listed fire alarm control units. NOTE: *Rev/Recerj 03-29-2006 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:0217 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: jgoyette@tycoint.com DESIGN: Models 4O989780,;9780E, *..9772 9789, 9789E, 978915P, -9789TTP, 9791, 9791E, -9791T5P, 9791TTR9792,-9792E, -9792TSP, 97921TP, -9793,-9793E, -9793T5P, -979311P, -9794, -9794T5P, -979411P, -9795, -9795T5P, -9795T1P, -9796, -9796T5P, -97961TP; G5A4098-9780, -9792, -9793, -9795 and -9796 smoke detector bases. These bases act as an interface between the sensor and the MAPNET controller. Bases are intended for use with the following units: Models 4098-9714 and G5A4098-9714 series photoelectric smoke detector (CSFM Listing No. 7272-0026:218); Model 4098-9717 ionization smoke detector (CSFM Listing No. 7271-0026:231); and Models 4098-9733, G5A4098-9733, *40989734 and *GSA40989734 heat detectors (CSFM Listing No. 7270-0026:216). Models 4098-9795, -9795T5P, -9795T1P, -9796, -979615P, -9796TTP; G5A4098-9795, and -9796 are only intended for use with Models 4098-9754 or G5A4098-9754 photoelectric smoke detector (CSFM Listing No.7272-0026:218). Refer to listee's printed data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as detector bases for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. Models 4098-9794, -9794T5P, -97941TP, -9795, -9795T5P, -97951TP, *9772 and G5A4098-9795 employ a sounder, which is also suitable for use as a fire alarm audible signaling device. These base/sounders CAN NOT produce the temporal code pattern in accordance with NFPA 72, 2002 Edition. If this temporal code is required, the sounder/base unit must be used with the control unit that can produce the temporal pattern. *Rev. 04-21-16 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other S Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0026:0218 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: SimplexloO Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: jgoyette@tycoint.com DESIGN: Models 4098-9714, *9774 -9714T5P, -9714TTP, -9754 -97541SP, -9754T1P; G5A4098-9714, and -9754 analog photoelectric type smoke detectors. Units are intended for use with smoke detector bases Models 4098-9789 978915P, -9789TTP, -9791, -9791T5P, * 9775 * -9776, *9777 -979111P, -9792, -9792T5P, 9792TTP, -9793, 9793T5P, -9793TTP, -9794, -9794T5P,-9794TTP; G5A4098-9792, and -9793 (CSFM Listing No. 7300-0026:217). Models 4098-9714, -9714T5P and -9714TTP are listed for use with Models 4098-9750-9751, -9752 and -9753 duct detector units (CSFM Listing No. 3240-0026:220) and Models 4098-9755, -9755T5P and -975511P duct detector units (CSFM Listing No. 3240-0026:241). Models 4098-9754, *.9779 -9754TSP, -9754TTP; G5A4098-9754 analog photoelectric type smoke detectors employ an integral supplemental heat sensor (1350 F fixed temperature and 1200 F rate of rise). This heat sensor is intended for use as a supplemental device to the smoke detector and is not intended for use in lieu of required heat detectors. Refer to listee's printed data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Model 4098-9714 with Model 4098-9751 is suitable for installations inside air ducts with air velocities between 0-2000 fpm. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires which smolder for hours before bursting into flames. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. *Revision 12-13-2016 dc . This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE C . LISTING No. 7125-0026:0316 Page 1 of 1 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: jgoyette@tycoint.com DESIGN: Models' -,4906-9101, -9102, -9103, and 9104multi-candela, non-addressable, synchronizable strobe lights. Models 4906-9101 and -9103 are for wall mount. Models 4906-9102 and -9104 are for ceiling mount. Synchronizing modules are required for synchronizing strobe lights if the interconnected control unit does not provide NAC synchronization capabilities. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 16-33 VDC Candela: 15, 30, 75, and 110 cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as strobe lights for use with separately listed compatible fire alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. These units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. NOTE: 06-23-04 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - . FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM - LISTING SERVICE LISTING No. 7125-0026:0317 Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: jgoyette@tycoint.com DESIGN: Models 4906-91274906-9129 wall mount and Models 4906-9128 and4906-9130 ceiling mount multi-candela horn/strobes. Refer to listee's data sheet for detailed product description and operational considerations. RATING: Electrical: 16-33 Vdc Candela: 15, 30, 75, ll0cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. For indoor use only. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as multi-candela horn/strobes with a signaling appliance suitable for the hearing impaired when used with listee's separately listed fire alarm control units. All models require the use of Model 4905-9938 (CSFM Listing No. 7125-0026:235) sync control module unless the horn/strobes are used with the listee's Model 4010 (CSFM Listing No. 7170-0026:226) or 4100 (CSFM Listing Nos. 7170-0026:250 and 7165-0026:251). Refer to listee's Installation . Instruction Manual for details. NOTE: 07-22-2004 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL . FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 3550-1039:0100 Page 1 of 1 CATEGORY: 3550-- DOOR CLOSER/HOLDERS/RELEASING DEVICES LISTEE: R5G2700 Junipero Ave. Signal Hill, CA 90755 Contact: Helen Moyer (562) 630-4684 Fax (562) 529-5100 Email: helen@rsgsecurity.com DESIGN: Models DH-12,C-24, '-120, -1224, -24120, and -24220 door closer/holders. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 12V, 24V, 120V, and 220V INSTALLATION: In accordance with listee's printed installation instructions and applicable codes and ordinances. The system is intended to be mounted in a horizontal position only. MARKING: Listee's name, model number, rating and UL label. APPROVAL: Listed as door closer/holders for use with separately listed compatible detectors and fire alarm control units. *Rev. 06-13-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division