Loading...
HomeMy WebLinkAbout1819 ASTON AVE; ; AS090003; PermitJob Address: 1819 ASTON AV Permit Type: SPRINK Parcel No: 2121201100 Lot #: 0 Reference No.: Status: ISSUED Applied 1/7/2009 Approved: 1/7/2009 Issued: 1/7/2009 City of Carlsbad Sprinkler Permit Permit No: AS090003 PC #: Inspector: Project Title: ADVANTAGE GROUP T.I. FIRE SPRINKLER PLAN CHECK & INSPECTIONS Applicant: WEST COAST FIRE PROTECTION 271 ROYMAR RD SUITE F OCEANSIDE, CA (760)754-8472 Owner: JETT&JONES L L C T LAWRENCE JETT P0 BOX 455 SANTA YNEZ CA Fees ($) Add Fees ($) Total(s) Balance (5) 130 0 130 0 many angles, reducing assembly effort. This sprin- kler is available in various temperature ratings (see chart on page 2) and fin- ishes to meet many design requirements. The recessed pendent should be utilized with a Model V27 recessed escutcheon which pro- vides up to VV (19 mm) of adjustments. Sprinkler Operation The operating mechanism is a frangible glass bulb which contains a heat responsive liquid. During a fire, the ambient tempera- ture rises causing the liquid in the bulb to expand. When the ambient temper- ature reaches the rated temperature of the sprin- kler, the bulb shatters. As a result, the waterway is cleared of all sealing parts and water is discharged towards the deflector. The deflector is designed to dis- tribute the water in a pat- tern that is most effective in controlling the fire. Coverage For coverage area and sprinkler placement, refer to NFPA 13 standards. ./.i,t auIicr AUTOMATIC SPRIN K-2 FIRE PROTECTION PF 40.10 V27, K5.6 Models V2703, V2704, V2707 and V2708 Standard Spray Upright, Pendent and Recessed Pendent Standard and Quick Response PRODUCT DESCRIPTION These Model V27 standard spray sprinklers are designed to produce a hemispherical spray pat- tern for standard commer- cial applications. They are 707 V2708 available with either stan- Recessed dard or quick response Pendent bulbs. The design incorpo- () (j) rZFM rates state-of-the-art, heat responsive, frangible glass j see Victaulic bulb design (standard or publication 1001 quick response) for prompt, V2708 precise operation. The die cast frame is more streamlined and attractive than traditional sand cast Pendent frames. It is cast with a V2703 hex-shaped wrench boss to V2704 ' allow easy tightening from Upright TECHNICAL SPECIFICATIONS Models: V2703, V2704, V2707 V2708 Style: Pendent, Upright or Recessed Pendent Nominal Orifice Size: ½ (13 Trim) K-Factor: 5.6 Imp. (8,1 S.l.A) Nominal Thread Size: ½' NPT (15 mm) Max. Working Pressure: 175 psi (1200 kP Factory Hydrostatic Test: 100% @ 500 psi (34 50 kP Mm. Operating Pressure: 7 psi (48 kPa) Temperature Rating: See chart on page 2. MATERIAL SPECIFICATIONS Upright Deflector: Bronze per UNS C22000 Pendent Deflector: Bronze per UNS C51000 Bulb: Glass with glycerin solu- tion. Bulb Nominal Diameter: U Standard: 5.0 mm U Quick Response: 3,0 mm Load Screw: Bronze per UNS C65100 Pip Cap: Bronze per UNS C65 100 Spring: Beryllium nickel Seal: Teflon* tape Frame: Die cast brass 65-30 Lodgement Spring: Stainless steel per UNS S30200 ACCESSORIES Installation Wrench: U Open End: V27 O Recessed: V38, V38-3 Cl Socket: V27 Finishes: U Plain brass U Chrome plated U White painted** U Custom painted** o Lead** 155, 200, 286SR Only: U Wax U Wax over lead** For cabinets and other accesso- ries refer to separate sheet. NOTE: Weather resistant recessed escutcheons available upon request. For K-Factor when pressure is mea- sured in Bar, multiply Si. units by 10.0. Teflon is a registered trademark of Dupont Co. UL Listed for corrosion resistance in all configurations. VICTAULIC® IS AN ISO 9001 CERTIFIED COMPANY Victaulic Company of America Victaulic Company of Canada Victaulic Europe Victaulic America Latina Victaulic Asia Pacific Phone: 1-800-PICK-VIC (1.800-742-5842) Phone: 905-884-7444 Phone: 32-9-381-1500 Phone: 610-559-3300 Phone: 65-6235-3035 Fax: 610-250-8817 Fax: 905-884-9774 Fax: 32-9-380-4438 Fax: 610-559-3608 Fax: 65-6235-0535 e-mail:pickvic@viclaulic.com e-mail: viccanada@victaulic.com e-mail: viceuro@victaulic.be e-mail: vical@victaulit.com e-mail: vicap@victaulic.com 2544 Rev.D 8103 0 Registered Trademark of Victaulic 0 Copyright 2003 Victaulic Printed in U.S.A. I I APPROVALSILISTINGS Nominal Approved Temperature Ratings °FI°C t Orifice Size K-Factor Inches Imperial Deflector Model millimeters S.LA Response Type UL FM ULC NYC!MEAt CSFM § ½ 5.6 135-360 135-360 135-360 135-360 135-360 V2703 13 8,1 Standard Upright 57-182 57-182 57-182 57-182 ½ 5.6 135-350 135-360 135-360 135-360 135-360 V2707 13 8,1 Standard Pendent 57-182 57-182 57-182 57-182 57-182 1h 5.6 Recessed Pendent 135-360 135-200 135-360 135- 360 135-360 V2707 13 8,1 Standard Up to ~' Adjumment 57-182 57-93 57-182 57-182 57-182 ½ 5.6 135-286 135-286 135-286 135-286 135-286 V2104 13 8,1 Quick Upright 57-141 57-141 57-141 57-141 57-141 1h 5.6 135-286 135-286 135-286 135-286 135-286 V2708 13 811 Quick Pendent 57-141 57-141 57-141 57-141 57-141 ½ 5.6 Recessed Pendent 135-200 135-200 135-200 135-200 135-200 V2708 13 8.1 Quick Up to ½' Adjustment 57-93 57-93 57-93 1 57-93 57-93 ½ 5.6 t Recessed Pendent 135-200 No 135-200 135-200 135 -200 V2708 13 8,1 k Quick Upto~'Adjustrnnnt 5793 5793 Listings and approval as or printing. Lz All arc approvca open, except ror areas ucsiyiiawu 'JO For K-Factor when pressure is measured in Bar, multiply S.I. units by 10. MEA #62-99-E. § CSFM #7690-0531:112 RATINGS All glass bulbs are rated for temperatures from -67°F (-55°C) up to those shown in adjacent table. Temperature -FI°C Nominal Maximum Sprinkler Victaulic Glass Temperature Part Temperature Ambient Temp. Bulb Classification Identification Rating Allowed Color Ordinary A 135 57 100 38 Orange Ordinary C 155 100 68 38 Red Intermediate E 17 5 65 150 Yellow Intermediate F 200 150 93 65 Green High J 286 141 225- 107 Blue Extra High t K 360 182 300 1 149 1 Purple - M Open I I No Bulb I Standard response only, All are approved open, except for areas designated No. - 150165 if wax coated. ORDERING INFORMATION Please specify the following when ordering: LI Sprinkler Model Number U K-Factor U Sprinkler Finish U Style 0 Thread Size U Escutcheon Finish U Temperature Rating U Quantity U Wrench Model Number - Always read and understand installation, care, and maintenance instructions, supplied with each box of sprinklers, before proceeding with installation of any sprinklers. Always wear safety glasses and foot protection. Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. Installation rules, especially those governing obstruction, must be strictly followed. Painting, plating, or any re-coating of sprinklers (other than that supplied by Victaulic) is not allowed. Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pamphlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters, P.O. Box 31, Easton, Pennsylvania 18044-0031, 610-559-3300. 40.10 -2 DIMENSIONS 1Ae (37 mm) 2W I )80 mm) 1W 1W (41 mm) 2W @1 mm) 1 1 m (60 mm) I (25 mm) Standard Pendent - V2707, V2708 Standard Upright - V2703, V2704 Recessed - V2707, V2708 (Drawing not to scale) 2W'(60 mm) Max. Hole 2(51 mm) Mm. He (24 mm) (1rnm) Typical Ceiling fla Irp (24 mm) (43 em) 1,Yle Alp Finished SurfaceJ I m MAXIMUM RECESS (75 mm) MAXIMUM EXTENSION Y4" Adjustment Recessed - V2707, V2708 (Drawing not to scale) AVAILABLE WRENCHES V27 Socket V38 or V38-3 Recessed V27 Open End V2707, V2708 Pendent V2707,V27O8Recessed-Pendent V2703, V2704 Upright - / / DISTRIBUTION PATTERNS MODELS V2701, V2708 K5.6 STANDARD PENDENT AND RECESSED PENDENT DISTRIBUTION PATTERNS - TRAJECTORY 10' - I I I I I I I I 3,0 m 8' 2,4 m 6' 1,8 m 4' 1,2 m 2' 0.6 m 0 2' 4' 6' 8' 10' 12' 14' 0,6w 1,2 m 1,8 m 2,4w 3,0 m 3,7 m 4,3 m MODELS V2103, V2704 K5.6 STANDARD UPRIGHT DISTRIBUTION PATTERNS - TRAJECTORY 7 psi 48 kPa 15 psi 103 kPa 30 psi ------- 207 kPa m ---::— - — _____.\_ - m - _ - m \ \ - 0.6 m 1,2 m 1,8 m 2,4 m 3,0 m 3,7 m 4,3 m 4,9 m NOTES: Data shown Is approximate and can vary due to differences In Installation. These graphs illustrate approximate trajectories, floor-wetting, and wall-wetting patterns for these specific Victaulic FireLock Automatic Sprinklers. They are provided as Information for guidance In avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation. Refer to the appropriate NFPA National Fire Code and the authority having jurisdiction for specific information regardlng.obstructlons, spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings, Approvals and War- ranties. All patterns are symmetrical to the centerline of the waterway. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. This product shall be manufactured by Victaulic Company. Al products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. 40.10-4 10' 3,0 m 8 2,4 6 1,8 4 1,2 2 0,6 C 7ps1 48 kPa 15 psi 103 kPa 30 psi 207 kPa FORM 2-J Automatic S rinkler Systems Contractor's Material and Test Certificate for Aboveground Piping Date: 1-30-09 Lanikai Lot 65 FILE COPY Property Address: 1819 Aston Ave., Carlsbad. Procedure Upon completion of work, inspection and tests shall be made by the contractor's representative and witnessed by an owner's representative. All defects shall be corrected and the system left in service before contractor's personnel finally leave the job. A certificate shall be filled out and signed by both representatives. Copies shall be prepared for approving authori- ties, owners, and contractors. It is understood that the owner's representative's signature in no way prejudices any claim against contractor for faulty material, poor workmanship, or failure to comply with approving authority's requirements or local ordinances. Plans Carlsbad Fire Accepted by [approving authority's Department Address Installation conforms to accepted plans? Yes x No Equipment used is approved? Yes x No If no, explain deviations. Instructions Has person in charge of fire equipment been instructed as to location of control valves and care and maintenance of this new equipment? Yes X No If no, explain. Have copies of appropriate instructions and care and maintenance charts and NFPA 13 been left on premises? Yes X No If no, explain. Location of System Supplies building (1) One building, riser in East Suite. Sprinklers Year of Orifice Temperature Make Model Manufacture Size Quantity Rating Victaulic Vic # V2708 2007 lIz 21 155 Pipe and Fittings Pipe conforms to standard. Yes X No Fittings conform to standard. Yes X No If no, explain. PAGE 1 of 3 Copyright © 2000 National Fire Protection Association FORM 2-J Automatic Sprinkler Systems Contractor's Material and Test Certificate for Aboveground Piping (cont.) Alarm Valve or Flow Indicator Alarm Device Maximum Time to Operate Through Test Pipe Type Make Model Mm. Sec. Dry Pipe Operating Test Dry Valve Q.O.D. Make Model Serial No. Make Model Serial No. Time to Trip Trip Point Time Water Alarm Through Water Air Air Reached Operated Test Pipe* Pressure Pressure Pressure Test Outlet* Properly Mm. Sec. Psi (Bar) Psi (Bar) Psi (Bar) Mm. Sec. Yes No Without Q.O.D. With Q.O.D. If no, explain. No dry system on site Deluge and Preaction Valves Operation Pneumatic Electhc Hydraulic Piping supervised? Yes No Detecting media supervised? Yes No Is there an accessible facility in each circuit for testing? Yes No If no, explain. No Deluge or preaction system on site Does each circuit operate Does each circuit Maximum Time to supervision loss alarm? operate valve release? Operate Release Yes No Yes No Mm. Sec. Make Model Test Description I-IYDROSTA71C: Hydrostatic tests shall be made at not less than 200 psi (13.6 bar) for two hours or 50 psi (3.4 bar) in 150 bar) for two hours. Differential dry be left above static pressure excess of psi (10.2 pipe valve clappers shall open during test to prevent damage. All aboveground piping leakage shall be stopped. FLUSHING: Flow the required rate until water is clear as indicated by no collection of foreign material in burlap bags at outlets such as hydrants and blow-offs. Hush at flows not less than 400 gpm (1514 L/min) for 4-in. (102-mm) pipe, 600 gpm (2271 L/min) for 5-in. (127-mm) pipe, 750 gpm (2839 L/min) for 6-in. (152-mm) pipe, 1000 gpm (3785 L/min) for 8-in. (203-mm) pipe, 1500 gpm (5678 1/mm) for 10-in. (254-mm) pipe and 2000 gpm (7570 1/mm) for 12-in. (305-mm) pipe. When supply cannot produce stipulated flow rates, obtain maximum available. *Mpcj irpri frnm tim incnprt-nr'c te'zt nin ic nnenc1 PAcF ? nf Copyright © 2000 National Fire Protection Association FORM 2-) Automatic S rinkler Systems Contractor's Material and Test Certificate for Aboveground Piping (cont.) Test Description (cont.) PNEUMATIC: Establish 40 psi (2.7 bar) air pressure and measure drop, which shall not exceed 1 1/2 psi (0.1 bar) in 24 hours. Test pressure tanks at normal water level and air pressure and measure air pressure drop, which shall not exceed 1 1/2 psi (0.1 bar) in 24 hours. Tests All piping hydrostatically tested at (200) psi (bar) for 2 hrs. Test at Static Dry piping pneumatically tested? Yes No N/A Equipment operates properly? Yes X If no, state reason. Drain test—Reading of gauge located near water supply test pipe: Static pressure: I psi (bar) Drain test—Residual pressure with valve in test pipe open wide: 6 psi (bar) Underground mains and lead-in connections to system risers flushed before connections made to sprinkler piping Verified by copy of the U Form No. 85B Yes X No Other Flushed by installer of underground sprinkler piping Yes X No Other If other, explain. Blank Testing Gaskets Number used 0 Locations 0 Number removed Welding Welded piping? Yes No X If yes, Do you certify as the sprinkler contractor that welding procedures comply with the requirements of at least AWS Dl 0.9, Level AR-3? Yes No N/A X Do you certify that the welding was performed by welders qualified in com- pliance with the requirements of at least AWS Dl 0.9, Level AR-3? Yes No N/A X Do you certify that welding was carried out in compliance with a documented quality control procedure to insure that all discs are retrieved, that openings in piping are smooth, that slag and other welding residue are removed, and that the internal diameters of piping are not penetrated? Yes No N/A Hydraulic Data Nameplate Nameplate provided? Yes X No If no, explain. Remarks Date left in service with all control valves open: 1-30-09 Sprinkler Contractor: West QgAst.Eire Protection Signatures of Test Wit sse For property owner (sign n)2 Date For sprinkler contractor (signed) ark Strecker Title Owner Date PAGE 3 of 3 Copyright © 2000 National Fire Protection Association FORM 2-K Automatic S rinkler Systems Contraclor's Material and Test Certificate for Underground Piping Date: 1-30-09 Property Name: Lanikai Lot # 65 Property Address: 1819 Aston Ave Carlsbad ca - Procedure Upon completion of work, inspection and tests shall be made by the contractor's representative and Witnessed by an owner's representative. All defects shall be corrected and the system left in service before ontractor's personnel finally leave the job. A certificate shall be filled out and signed by both representatives. Copies shall be prepared for approving authori- ties, owners, and contractors. It is understood that the owner's representative's signature in no way prejudices any claim against contractor for faulty material, poor workmanship, or failure to comply with approving authority's requirements or local ordinances. Plans Accented by Carlsbad Fire Department Address 1635 Faraday Ave Carlsbad Ca 92008 Installation conforms to accepted plans? Yes X No Equipment used is approved? Yes X No If no, explain deviations. Instructions Has person in charge of fire equipment been instructed as to location of control valves and care and maintenance of this new equipment? Yes X No If no, explain. Have copies of appropriate instructions and care and maintenance charts been left on Premises YES Yes X No If no, explain. Location Supplies north / Underground Pipes and Joints PiDe conforms to standard. NFPA 13 Yes X No Fittings conforms to standard. NFPA 13 Yes X No If no, explain. Joints needing anchorage clamped, strapped, or blocked in accordance with standard. NFPA 13 Yes X No If no, explain. Test Description FLUSHING. Flow the required rate until water is clear as indicated by no collection of foreign material in burlap bags at outlets such as hydrants and blow-offs. Flush at flows not less than 400 gpm (1514 L/min) for 4-in. (102-mm) pipe, 600 gpm (2271 L/min) for 5-in. (127-mm) pipe, 750 gpm (2839 L/min) for 6-in. (152-mm) pipe, 1000 gpm (3785 L/min) for 8-in. (203-mm) pipe, 1500 gpm (5678 L/min) for 10-in. (254-mm) pipe and 2000 gpm (7570 L/min) for 12-in. (305-mm) pipe. When supply cannot produce stipulated flow rates, obtain maximum available. PAGE 1 of 2 Copyright © 2000 National Fire Protection Association FORM 2-K Automatic Sprinkler Systems Contractor's Material and Test Certificate for Underground Piping (cont.) Test Description (cont.) HYDROSTATIC: Hydrostatic tests shall be made at not less than 200 psi (13.6 bar) for two hours or 50 psi (3.4 bar) above static pressure in excess of 150 psi (10.2 bar) for two hours. LEAKAGE: New pipe laid with rubber gasketed joints shall, if the workmanship is satisfactory, have little or no leak- age at the joints. The amount of leakage at the joints shall not exceed 2 qts per hr. (1 .89 L/h) per 100 joints irre- spective of pipe diameter. The leakage shall be distributed over all joints. If such leakage occurs at a few joints the installation shall be considered unsatisfactory and necessary repairs made. The amount of allowable leakage speci- fied above may be increased by 1 fl oz per in. valve diameter per hour (30 mL/25 mm/h) for each metal-seated valve isolating the test section. If dry barrel hydrants are tested with the main valve open, so the hydrants are under pressure, an additional 5 oz per minute (150 mL/min) leakage is permitted for each hydrant. Flushing Tests New underaround oioina flushed according to standard. Yes X No By (comoanv) If no. explain. How flushing flow was obtained: Public water X Tank or reservoir Fire pump Through what type opening Hydrant butt Open pipe X Lead-ins flushed according to standard Yes X No By (comoanv) If no, explain. How flushing flow was obtained Public water X Tank or reservoir Fire pump Through what type opening XX connection to flange and spigot Open pipe Hydrostatic Test All new underground piping hydrostatically tested at 200 psi (bar) for2 hours Joints covered? Yes No X Leakage Test Total amount of leakage measured: 0 gals (L) hours Allowable leakage: gals (L) 1.89 hours Hydrants Number installed: Tve and make: N/A All operate satisfactorily? Yes X No Control Valves Water control valves left wide open? Yes X No If no, state reason. Hose threads of fire department connections and hydrants inter- changeable with those of fire department answering alarm? Yes X Remarks Date left in service with all control valves open: 1-30-09 Installing Contractor: Signatures of Test Wi ess For property owner (sig Title' 'P Date For sprinkler contractor (signed) ark Strecker Title Owner Date PAGE 2 of 2 Copyright © 2000 National Fire Protection Association