Loading...
HomeMy WebLinkAbout1905 ASTON AVE; 100; FS060006; PermitCity of Carlsbad Fixed Systems Permit Permit No: FS060006 Job Address: 1905 ASTON AV Permit Type: FIXSYS Parcel No: 2121201300 Lot #: 0 Reference No.: Status: ISSUED Applied 5/12/2006 Approved: 6/9/2006 Issued: 6/9/2006 PC #: Inspector: Project Title: 3E COMPANY, SUITEIOO INERGEN PLAN CHECK & INSPECTION Applicant: AIRGAS FIRE PROTECTION 9010 CLAIREMONT MESA BL SAN DEIGO, CA 858-495-2327 Owner: H&M EAGLE L P P 0 BOX 3802 RCHO SANTA FE CA Fees ($) Add'I Fees ($) Total Balance ($) 120 0 120. 0 I ANSUL INERGEN DESIGNER Version 2. 1. 2 File: C:\Program Files\INERGEN DESIGN ER\Inergen Cale Data\06SRW1463F.inr Job: 065RW1463F Customer: 3E COMPANY Address: 1905 ASTON AVE SUITE-100 CARLSBAD CA 92008 REMARKS: SERVER ROOM Hazard Area Information Area: SERVER ROOM Design concentration 34.2% at 65° Fahrenheit Estimated maximum concentration 41.3% at maximum hazard temperature 75° Fahrenheit Gross volume of enclosure 1637 cubic feet Structural volume reductions 9.6 cubic feet Net volume of enclosure 1627.8 cubic feet Minimum INERGEN required 688.6 cubic feet Approximate INERGEN supplied 858. cubic feet Flooding factor .423 cubic feet of INERGEN per cubic feet of enclosure volume Maximum allowable wall strength 5.0 lbs./sq.ft. Area consists of one volume Volume 1: Length 17.2 ft Width 11.2 ft Height 8.5 ft 1 nozzles. Nozzle identifiers: 301 Agent Storage Conditions Number of cylinders: 2 each containing 429 cubic feet of INERGEN. Total agent 858 cubic feet Engineering units (ft, cu ft, psia) are specified Calculation based on 70 degree Fahrenheit pre-discharge Pipeline Temperature Calculation based on fixed nozzle and pipe sizes Pipe Data Input Sec 'Sec Nominal Length Elev 90's Side Thru Union! Noz EqI Start End Pipe Size (ft) (ft) Tee Tee Cplg Dia (ft) 1 2 1/2 -40 T 0.01 0.00 0 0 0 0 38.00 2 3 3/4-80T 1.00 0.00 1 0 0 0 0.00 3 4 3/4 - 80 T 0.50 0.50 1 0 0 0 2 cyl 0.00 4 5 3/4 - 80 1 0.00 0.00 0 0 0 0 Orifice 5 6 3/4-40T 2.10 2.10 0 0 0 1 0.00 6 7 3/4-.40T 13.70 0.00 1 0 0 0 0.00 7 8 3/4-401 1.50 0.00 1 0 0 0 0.00 1 (Data Input File Printout continued) I ANSUL INERGEN DESIGNER UL listed EX4510. FMRC Approved W.I.) 2Y0A9.AF, ULC listed CEx1151 Version 2.1.2 File: C:\Program Files\INERGEN DESIGN ER\Inergen Caic Data\06SRW1463F.inr Job Number: 06SRW1463F Pipe Data Input(Continued) File: C:\Program Files\INERGEN DESIGNER\lnergen Caic Data\06SRW1463F.inr Sec Sec Nominal Length Elev 90's Side Thru Union! Noz Eqi Start End Pipe Size (ft) (ft) Tee Tee Cplg Noz (ft) 8 9 3/4-40T 1.50 -1.50 1 0 0 0 0.00 9 301 3/4 - 40 T 0.01 0.00 0 0 0 1 0.339 0.00 2 (End of Data Input File Printout) I ANSUL INERGEN DESIGNER UL listed EX4510. FMRC Approved (J.l.) 2Y0A9.AF. ULC listed CEx1151 Version 2.1.2 File: C:\Program Files\INERGEN DESIGNER\Inergen Caic Data\06SRW1463F.inr Job Number 06SRW1463F for 3E COMPANY Address: I905ASTON AVE SUITE-100 CARLSBAD CA 92008 REMARKS: SERVER ROOM Aaent Storaae Conditions Storage pressure is 2175 psia at 70 degrees Fahrenheit. 429 cubic feet of INERGEN stored in each of 2 cylinders. Total agent in storage is 858 cubic feet. Time to discharge 772 cubic feet (90% of INERGEN) is 79.4 seconds Maximum pressure downstream of manifold orifice is 1434. psia Concentrations 95% Maximum Minimum Requested Time Cu Ft Concentration Concentration Concentration Area Volume (sec) INERGEN at Max. Temp. at Mm. Temp. at Min Temp. SERVER ROOM 1627.8 52 858.0 41.3% at 75°F 40.7% at 65°F 34.2% at 65°F Sea level equivalent oxygen: 12.3% at 75°F Free Vent Calculation Peak Maximum Wall Minimum Free Area Rate Strength Vent Area SERVER ROOM 1545.8 cfm 5.0 lbs./sq.ft. 59 sq. in. Pressure Drop Results Sec Sec Nominal Length Equiv Elev Tee/ Start Term Flow Start End Pipe Size (ft) Length(ft) (ft) Mfld psia psia (cfm) 1 2 1/2 40T 0.0 38.0 0.0 MFLD 1033 1009 421.4 2 3 3/4 80T 1.0 2.9 0.0 MFLD 1009 1008 421.4 3 4 3/4. 80T- 0.5 2.4 0.5 MFLD 1008 1005 842.7 4 5 ORIFICE .266 INCHES DRILL NO. H 1005 552 842.7 5 6 3/4 40T 2.1 2.4 2.1 552 662 842.7 6 7 3/4 40T 13.7 15.8 0.0 662 648 842.7 1 (Continued) ANSUL INERGEN DESIGNER UL listed EX4510. FMRC Approved (J.l.) 2Y0A9.AF, ULC listed CEx1151 Version 2. 1.2 File: C:\Program Files\INERGEN DESIGNER\Inergen Calc Data\06SRW1463F.inr Job Number: 06SRW1463F Pressure Drop Results (Continued) Sec Sec Nominal Length Equiv Elev Tee/ Start Term Flow Start End Pipe Size (ft) Length(ft) (ft) Mfld psia psia (cfm) 7 8 3/4 401 1.5 3.6 0.0 648 645 842.7 8 9 3/4 401 1.5 3.6 -1.5 645 642 842.7 9 301 3/4 40 T 0.0 0.4 0.0 642 642 842.7 Calculation based on 70 degree Fahrenheit pre-discharge Pipeline Temperature Pipe and Fittings Sec Sec Nominal Length Side Thru Unions/ EqI Start End Pipe Size (ft) 90's Tee Tee Cplqs (ft) 1 2 1/2 401 0.0 0 0 0 0 Cyl Valve 38 ft 2 3 3/4 801 1.0 1 0 0 0 3 4 3/4 801 0.5 1 0 0 0 4 5 3/4 80 1 0 0 0 0 Man. Orifice 5 6 3/4 401 2.1 0 0 0 1 6 7 3/4 401 13.7 1 0 0 0 7 8 3/440T 1.5 1 0 0 0 8 9 3/4 401 1.5 1 0 0 0 9 301 3/4 40T 0.0 0 0 0 1 Nozzle Performance Summary Nozzle Nominal Drill Drill Quantity (cu ft) Area Number Pipe Size Number Diameter Discharged Name 301 3/4 40 1 R 0.339 858.0 SERVER ROOM Messages/Errors ANSUL 150 bar INERGEN DESIGNER Version number 2.1.2 / 2 (Continued) ANSUL INERGEN DESIGNER UL listed EX4510. FMRC Approved (J.l.) 2Y0A9.AF, ULC listed CEx1151 Version 2. 1.2 File: C:\Program Files\INERGEN DESIGNER\Inergen Caic Data\06SRW1463F.inr Job Number: 06SRW1463F Calculation based on fixed nozzle and pipe sizes. Calculation done on 5/11/2006 at 9:03:30 AM Pipe schedule selected for pipe sizes downstream of the manifold orifice is based on the maximum pipe pressure for Grade A-5313, A-1 06B Seamless. To determine if other grades are acceptable, verify that the maximum pipe pressures for other grades are equal to or greater than the maximum anticipated downstream pressure. Calculation by Airgas West Fire Protection Gordon E. Swope 1340 E. Mission Blvd Pomona California 91766 Telephone: 909-868-5000 Fax: 909-397-0562 3 End of Printout p 1 OVED A110"gaso _ ___ _______ AIRGAS West Fire Protection 9010 CLAIREMONT MESA BLVD. SAN DIEGO, CA 92123 PHONE (858) 495-2327, FAX (858) 496-3820 3E COMPANY 1905 Aston Ave., Suite 100 Carlsbad, CA 92008 SUBMITTAL FOR: INERGEN (IG-541) Fire Suppression Systems Server Room DESIGN BY: Gordon E. Swope SET NICET#78621 (Senior System Designer) INERGEN FIRE SUPPRESSION SYSTEM S [IJ O Ineçp Clean System Components UL EX4510 6-1-02 Page 1-1.1 REV 3 CV-98 Valve / Cylinder Shipping Assembly Description The cylinder is factory filled with INERGEN® agent. A single cylinder may be used or multiple cylinders can be manifold- ed together to obtain the required quantity of agent for total flooding. The cylinder valve can be actuated electrically, pneumatically, and/or manually with approved valve actua- tion components. All valves are equipped with an anti-recoil feature. The cylinders are shipped with a maintenance record card and protective shipping cap attached to the threaded neck of each cylinder. This cap entirely encloses and protects the valve while in shipment. The equivalent length of the valve is equal to 20 ft. (6.1 rn) of 1/2 in. Sch. 40 pipe. Component Material Approvals Cylinder Steel Meets DOT 3AA2300 Valve Brass Safety Relief Valve Brass Valve/Cylinder Assembly FMRC Approved UL Listed (EX-4510) Shipping Cap Steel Shipping Nominal Cylinder Actual INERGEN Approximate Dimension Dimension Assembly Size Agent Quantity Weight A B Part No. ft.3 (m3) ft.3 m3 lb. (kg) in. (cm) in. (cm) Shipping Assemblies - Red Standard Paint 426147 200 (5.7) 205 (5.8) 128 (58) 52.7 (129) 8.5 (21.6) 426148 250 (7.1) 266 (7.5) 169 (77) 57.7 (147) 9.3 (23.5) 426149 350 (9.9) 355 (10.1) 217 (98) 59.7 (152) 10.7 (27.3) 426620 LC-350 (9.9) 355 (10.1) 217 (98) 60.2 (152.9) 10.5 (26.7) 426594 LC-425 (12.0) 429 (12.1) 246 (111.6) 70.5 (179.1) 10.5 (26.7) 426150 435* (12.3) 439 (12.4) 260 (117.9) 66.9 (170.0) 11.0 (27.9) Shipping Assemblies - Red Corrosion Resistant Paint 426256 200 (5.7) 205 (5.8) 128 (58) 52.7 (129) 8.5 (21.6) 426257 250 (7.1) 266 (7.5) 169 (77) 57.7 (147) 9.3 (23.5) 426258 350 (9.9) 355 (10.1) 217 (98) 59.7 (152) 10.7 (27.3) 426621 LC-350 (9.9) 355 (10.1) 217 (98) 60.2 (152.9) 10.5 (26.7) 426595 LC-425 (12.0) 429 (12.1) 246 (111.6) 70.5 (179.1) 10.5 (26.7) 426259 435 (12.3) 439 (12.4) 260 (117.9) 66.9 (170.0) 11.0 (27.9) * NOTE: For Shanghai version, order Part No. 430935. Canadian TC Approved Shipping Nominal Cylinder Actual INERGEN Approximate Dimension Dimension Assembly Size Agent Quantity Weight A B Part No. ft.3 (m3) ft.3 m3 lb. (kg) in. (cm) in. (cm) Shipping Assemblies - Red Enamel Paint 426712 200 (5.7) 205 (5.8) 128 (58) 52.7 (129) 8.5 (21.6) 426713 250 (7.1) 266 (7.5) 169 (77) 57.7 (147) 9.3 (23.5) 426714 350 (9.9) 355 (10.1) 217 (98) 59.7 (152) 10.7 (27.3) 427551 LC-425 (12.0) 429 (12.1) 246 (111.6) 70.5 (179.1) 10.5 (26.7) 426715 435 (12.3) 439 (12.4) 260 (117.9) 66.9 (170.0) 11.0 (27.9) Shipping Assemblies -Red Epoxy CR Paint 426716 200 (5.7) 205 (5.8) 128 (58) 52.7 (129) 8.5 (21.6) 426717 250 (7.1) 266 (7.5) 169 (77) 57.7 (147) 9.3 (23.5) 426718 350 (9.9) 355 (10.1) 217 (98) 59.7 (152) 10.7 (27.3) 427552 LC-425 (12.0) 429 (12.1) 246 (111.6) 70.5 (179.1) 10.5 (26.7) 426719 435 (12.3) 439 (12.4) 260 (117.9) 66.9 (170.0) 11.0 (27.9) CYLINDER SHIPPING CAP 0 PRESSURE VALVE SHIPPING CAP GAUGE RECORD VALVE TAG HEIGHT TO OUTLET CENTER A 002251 CV-98 INERGEN Valve The CV-98 valve has a ten (10) year warranty. The valve requires no internal maintenance. The valve is sealed closed and must not be disassembled. If there is ever a malfunction of the CV-98 valve, the complete valve must be sent back to Ansul for warranty replacement. If the exter- nal seal is broken, the warranty is voided. NOTE: Use Flexible Discharge Bend, Part No. 427082, when attaching valve to supply pipe or manifold. ANSUL and INERGEN are trademarks of Afoul Incorporated or its affiliates. 3111N. PRESSURE (89 mm) GAUGE REFERENCE SAFETY REUEF VALVE 002252 fl ANSUL INCORPORATED. ONE STANTON STREET MARINETTE, WI 54143-2542 715-735-7411 Form No. F-9877-3 ©2002 Afoul Incorporated Litho in U.S.A. ANSUL Ineç Clean Agent Description The valve Flexible Discharge Bend (Part No. 427082) is a 5/8 in. (1.59 cm) I.D. extra-heavy flexible hose which con- nects the valve discharge outlet to the fixed piping or head- er manifold. The discharge bend has a special female thread for connecting to the valve outlet and a male 1/2 in. NPT thread for connecting to the fixed piping or manifold. b. The discharge bend will withstand a pressure of 9000 psi (621 bar). Its flexible connection allows for easy alignment of multiple cylinder banks to fixed piping. Each bend has a built-in check valve that prevents loss of agent should the system discharge while any cylinder is removed. The equivalent length of this hose is equal to 18 ft. (5.5 m) of 1/2 in. Sch. 40 pipe. System Components UL EX-4510 5-1-00 Page 1-12 REV.4 Flexible Discharge Bend Shipping Assembly Part No. Description 427082 Flexible discharge bend 842430 Washer Component Material Thread_Size/Type Approvals Valve End Manifold End 5/8 in. Flexible SAE 100 R2 Special to 1/2 in. NPT Male FMRC Approved Discharge Bend Type AT mate with UL Listed (EX-4510) CV9O and CV-98 Valve 18 718 IN. FEMALE ADAPTOR (47.9 cm) (BRASS) 1/2 IN. NPT WASHER MALE COUPLING CHECK SWAGE ON VALVE END 4 MANIFOLD/END ANSUL and INERGEN are trademarks of Ansul Incorporated or its affiliates. ANSUL IN)RPORATEO, ONE STANTON STREET MARINETrE, Wi 54143-2542 715-735-7411 Form No. F-9306-6 92000 Ansul Incorporated Litho in U.S.A. System Components ANSUL® UL EX-4510 11-1-00 Page 1-3.7 he HF Electric Actuator 0 Description Electrical actuation is accomplished by an HF electric Actuator, Part No. 73327, interfaced through an AUTOPULSE® Control System. This actuator can be used in hazardous, indoor environments where the ambient tem- perature range is between 0 OF to 130 OF (-18 °C to 54 °C). The HF electric actuator meets the requirements of N.E.C. Class I, Div. 1, Groups B, C, D and Class Il, Div. 1, Groups E, F, G. A maximum of two HF electric actuators can be used on a single AUTOPULSE release circuit. When utiliz- ing only one HF electric actuator, an in-line resistor, Part No. 73606, is required in the supervised release circuit. In auxiliary or override applications, a manual-local override valve actuator or a manual cable pull actuator can be installed on top of the HF electric actuator by removing the safety cap. An arming tool, Part No. 75433, is required to reset the actuator after operation. The actuator contains a standard 1/2 in. threaded female straight connector for electrical con- duit hookup. Technical Information Nominal Voltage: ..........12 VDC @ 0.57 amps Rated Voltage: Minimum ...................12.0 VDC Maximum: ...................14.0 VDC Thread Size/Type: ........1/2 in. straight female for electrical conduit hookup Material: Body ........................Brass Plunger: .................Stainless Steel Listings and Approvals UL .........................E91021 ULC..........................1165 FM ........... .............2T8A9.AF 2 1/4 IN. (57 mm) 0 ANSUL and INERGEN are trademarks of Ansut Incorporated or its affiliates. ANSUL INaIRPORATED, ONE STANTON STREET, MARINETTE. WI 54143-2542 715-735-7411 Form No. F-2001067 @2001 Ansut Incorporated Litho in U.S.A. System Components ANSUL System EX-4510 11-1-00 Page 1-3.6 flAeJc Booster Actuator Description The Booster Actuator, Part No. 428949, is used when elec- tric actuation is required on the 1 in. selector valve, 2 in. selector valve, or the CV-98 cylinder valve. The actuator mounts directly to the component and then a HF electric actuator mounts to the top of the booster actuator. The Booster Actuator requires resetting after actuation. A Reset Tool, Part No. 429847, is available for this use. 11/4-18 UNEF _ 3.025 / 1 1/8 - 18 UNEF 006037 ANSUL and INERGEN are trademarks of Ansul Incorporated or its affiliates. ANSUL INCORPORATED, ONE STANTON STREET MARINE1TE, WI 54143-2542 715-735-7411 Form No F-2001066 @2001 Ansul Incorporated Litho in U.S.A. ANSUL Ine 0 ume cgew, Description The manual lever release actuator provides a manual means of actuating cylinder valves and selector valves. This can be accomplished by direct manual actuation of its pull lever or cable actuation when used in conjunction with a remote manual pull station. When used with a remote man- ual pull station, the pull station must contain the compo- nents necessary to meet the actuator lever traveling requirements of 7 in. (178 mm). The actuator is shipped with ring pin and chain attached. If the ring pin is not required, it must be removed. Failure to remove the ring pin/chain assembly will prevent system actuation if a remote cable pull actuation system is employed and the ring pin is accidentally installed in the actuator. I Four actuators are available. Each is designed for a specific component. * Add 19/16 in. (3.9 cm)to height when lever is in the straight up position. System Components UL EX-4510 11-1-00 Page 1-4.1 REV. 3 Lever Release Actuator Component Material Approvals All Manual Brass with FMRC Approved Cable-pull Stainless UL Listed Actuators Steel Pin (EX-4510) Shipping Assembly Part No. Description 842484 Lever Release (1 1/4-18 mounting thread) - Mounts directly to pressure actuator on 2 1/2 in., 3 in. and 4 in. selector valves. 423309 Lever Release (1 1/8-18 mounting thread) - Mounts directly to a CV-98 electric actuator. Mounts directly to a CV-98 cylinder valve. 70846 Lever Release (1 1/4-18 mounting thread) - Mounts directly to an HF electric actuator. 427207 Lever Release (1 1/8-18 mounting thread) - Mounts directly to the 1 in. and 2 in. selector valves. Mounts direct- ly to pressure operated stackable actu- ator for I in. and 2 in. selector valves. Actuator has the handle painted red. ANSUL and INERGEN are trademarks of Ansut Incorporated or its affiliates. ANSUL INC3]RPORATED, ONE STANTON STREET MA1tNETFE. WI 54143-2542 715-735-7411 Form No. F-9879-3 02001 Ansul Incorporated Litho in U.S.A. ANSUL® Ineç CIGn Agent System Components UL EX-4510 11-1-00 Page 1-15 REV.6 Pressure Reducer/Union Description The pressure reducer/union is required to restrict the flow of INERGEN® agent thus reducing the agent pressure down stream of the union. The 3000 psi (206.9 bar) NSCWP union contains a stainless steel orifice plate which is drilled to the specific size hole required based on the flow calculation.* The orifice plate provides readily visible orifice identification. The orifice union is available in six sizes: 1/2 in., 3/4 in., 1 in., 1 1/4 in., 1 1/2 in., and 2 in. NPT. All pressure reducer/unions must be installed in the piping with the orifice identification tab on the pressure inlet side of the system. The 11/4 in., 11/2 in. and 2 in. orifice unions must be installed per the direction of the flow arrow stamped on the body. * DIRECTI OF FLOV VISIBLE ORIFICE IDENTIFICATION 052197 Shipping Assembly Part No. Description A B C 416677 1/2 in. NPT pressure reducer/union 2.06 in. (5.2 cm) 1.18 in. (2.9 cm) 1.95 in. (4.9 cm) 416678 3/4 in. NPT pressure reducer/union 2.38 in. (6.1 cm) 1.50 in. (3.8 cm) 2.38 in. (6.1 cm) 416679 1 in. NPT pressure reducer/union 2.63 in. (6.7 cm) 1.78 in. (4.5 cm) 2.77 in. (7.0 cm) 416680 1 1/4 in. NPT pressure reducer/union 2.94 in. (7.5 cm) 2.04 in. (5.2 cm) 3.31 in. (8.4 cm) 416681 1 1/2 in. NPT pressure reducer/union 3.31 in. (8.4 cm) 2.31 in. (5.9 cm) 3.70 in. (9.4 cm) 416682 2 in. NPT pressure reducer/union 3.56 in. (9.0 cm) 2.85 in. (7.2 cm) 4.39 in. (11.2 cm) Component Material Thread Size Approvals Pressure Reducer/ Body: Forged 1/2, 3/4, 1, FMRC Approved Union Steel 1 1/4,1 1/2, UL Listed (EX-4510) 2 in. NPT Orifice Plate: Stainless Steel 1 NOTE: Refer to "Nozzle/Pressure Reducer Range Chart" in Design Section for detailed orifice range information. * Orifice diameter must be specified when placing order. ANSUL and INERGEN are trademarks of Ansul Incorporated or its affiliates. ANSUL INCORPORATED, ONE STANTON STREET. MARINErIE. WI 54143-2542 715-735-7411 Form No. F-9311-8 02001 Ansul Incorporated Litho in U.S.A. Shipping Assembly Part No. Description 426138 1/4 in. NPT nozzle 426139 3/8 in. NPT nozzle 426140 1/2 in. NPT nozzle 426141 3/4 in. NPT nozzle 426142 1 in. NPT nozzle 426143 1 1/4 in. NPT nozzle 426157 1 1/2 in. NPT nozzle 426144 2 in. NPT nozzle 426145 2 1/2 in. NPT nozzle 426146 3 in. NPT nozzle P. Size A-in. B-In. C-In. 1/4 in. 5/8 19/16 21/32 3/8 in. 3/4 15/8 23/32 1/2 in. 15/16 131/32 27/32 3/4 in. 1 1/8 25/32 7/8 1 in. 113/32 29/16 1 1 1/4 in. 1 3/4 23/4 1 1/16 11/2 in. 2 231/32 11/16 2in. 23/8 3 1 21/2in. 3 31/2 1 3 in. 31/2 41/8 1 1/4 ANSUL 111AefltVy ,J System. System Components UL EX-4510 11-1-00 Pagel-16.1 REV. 2 1800 Discharge Nozzle 0 Description Discharge nozzles are designed to direct the discharge of INERGEN® agent using the stored pressure from the cylin- ders. Ten sizes of nozzles are available. The system design specifies the orifice size to be used for proper flow rate and distribution pattern*. The nozzle selection depends on the hazard and location to be protected. The 1800 nozzle is commonly used when nozzle placement is at the wall. Standard nozzles are constructed of brass. An index mark is stamped on the bottom of the nozzle to indicate the aiming direction. Component Material Thread Size Nozzle Body: Brass 1/4, 3/8,1/2, 3/4,1, 1 1/4,1 1/2, 2, 2 1/2,3 NPT B t 0 1 IN DEX MARK 002742 0 NOTE: Refer to "Nozzle/Pressure Reducer Range Chart" in Design Section for detailed orifice range information. 22 002743 * Orifice diameter must be specified when ordering nozzle. Refer to Orifice Size Chart in Manual Appendix Section. ANSUL and INERGEN are trademarks of Afoul Incorporated or its affiliates. ANSUL INCORPORATED, ONE STANTON STREET. MAIRINETTE, WI 54143-2542 715-735-7411 Form No. F-99020-1 020DI Ansul Incorporated Litho in U.S.A. ANSUL System Components UL EX-4510 3-1-99 Page 1-16.2 jtemS In Nozzle Deflector Shield Description The INERGEW system nozzle deflector shield is used to control the pattern of the discharge of the INERGEN agent. The deflector shield helps keep the agent discharge away from false ceiling tiles and fragile light fixtures, avoiding damage to them. The deflector shields are constructed of steel and painted with a cameo cream colored paint. They are available in five sizes. Component Material Approvals Nozzle Steel FMRC Approved Deflector UL Listed (EX-4510) Shield n Shipping Assembly Part No. A Inlet NPT B Length of Coupling C Overall Length D Deflector O.D. E Coupling O.D. 417708 1/2 in. 1 7/8 in. 3 in. 33/8 in. 11/8 in. (4.8 cm) (7.6 cm) (8.6 cm) (2.9 cm) 417711 3/4 in. 2in. 31/4in. 33/8in. 13/8 in. (5.1 cm) (8.3 cm) (8.6 cm) (3.5 cm) 417714 1 in. 2 3/8 in. 3 13/16 in. 4 7/8 in. 13/4 in. (6.0 cm) (9.7 cm) (12.4 cm) (4.4 cm) 417717 11/4 in. 25/8 in. 43/16 in. 47/8 in. 21/4 in. (6.7 cm) (10.6 cm) (12.4 cm) (5.7 cm) 417720 1 1/2 in. 3 1/8 in. 4 29/32 in. 5 21/32 in. 2 1/2 in. (7.9 cm) (12.5 cm) (14.4 cm) (6.4 cm) NOTE: There are no deflector shields available for the 2, 2 1/2, or 3 in. models. AA C I 003651 D ANSUL and INERGEN are trademarks of Ansut Incorporated or its affiliates. ANSUL INCORPORATED, ONE STANTON STREET, MARINErrE, WI 54143-2542 715-735-7411 Form No. F-94152.1 (51999 Afoul Incorporated Litho in U.S.A. ANSUL System Components UL EX-4510 11-1-00 Page 1-18 REV 3 Lfleç.0 1 Pressure Switch - DPST Description The pressure switch is operated by the INERGENTM agent pressure when the system is discharged. The pressure switch can be used to open or close electrical circuits to either shut down equipment or turn on lights or alarms. The double pole, single throw (DPST) pressure switch is con- structed with a gasketed, water tight housing. The housing is constructed of malleable iron, painted red. A 1/4 in. NPT pressure inlet is used to connect the 1/4 in. pipe from the INERGEN system. The pressure switch can be installed either before or after the pressure reducer in the distribution piping. Minimum operating pressure is 50 PSI (3.5 bar). Shipping Assembly Part No. Description 846250 Pressure switch - DPST Component Material Thread Size/Type Electrical Rating Approvals Pressure Switch Switch: Conduit Inlet: 3/4 in. NPT Female 2 HP - 240 VAC/ FMRC Approved DPST BAKELITE Pressure Inlet: 1/4 in. NPT Female 480 VAC UL Listed (EX-4510) Housing: 2 HP —250 VDC, Malleable 30A - 250V AC/DC Iron 5A - 480V AC/DC Piston: Brass Cover: Brass 35181N. (9.2 cm) MALLEABLE IRON - -. BRASS RESET I 2 718 IN. TO ELECTRICAL FINISH -REDRAINT 'V PLUNGER (7.3 cm) EQUIPMENT TO BE CONTROLLED MOISTURE-PROOF JOINT 52, r t_l GASKET NUT j, lJ RING GASKET NAM 1 © EPLATE 0 0 DOUBLE POLE - II HEAVY DUTY TOGGLE SWITCH 4 9/16 IN. WITH FULLY (11.5 cm) ENCLOSED BAKELITE BASE - _jj MOUNTING HOLE - BRASS PISTON t.LTJJU11 PISTON O RING GASKET TO POWER 004593 L. 3/4 IN. I ELECTRICAL _1L - - CONDUIT 19/64 IN. (7.5 mm) OUTLETS l 114 IN. UNION ----øj J TYP. 2 PLACES 1/4 IN. PIPE L —1 FROM CYLINDERS '-. 000716 0 Dfr%r\tLI I IS a traoemarK 01 union carblce corp. ANSUL and INERGEN are trademarks of Ansul Incorporated or its affiliates. ANSUL INCORPORATED, ONE STANTON STREET MAJRINETrE. WI 54143-2542 715-735-7411 Form No. F-9327-5 ©2000 Ansut Incorporated Litho in U.S.A. C System Components ANSUL® UL EX-4510 3-1-99 Page 1-17 Re a REV. 7 Cylinder Bracketing Description The cylinder bracketing is designed to rigidly support the installed INERGEN® agent cylinders. The bracketing compo- nents are constructed of heavy structural steel. Bracket assemblies are available in modules for two to six cylinders and can also be connected together for any combination over six. Bracketing can be assembled to support single row, double row or back-to-back rows of cylinders. Bracketing components are painted with a red enamel coating. Uprights and back frame assemblies can be bolted or welded together, which ever makes the installation more convenient. Component Material Approvals Bracketing Steel FMRC Approved UL Listed (EX-4510) Shipping Assembly Part No. Description 845120 200 ft.3 (5.7 m3) cylinder strap (single cylinder) 845244 200 ft.3 (5.7 m3) cylinder channel with nuts and bolts (single cylinder) 845121 250 ft.3 (7.1 m3) cylinder strap (single cylinder) 845261 250 ft.3 (7.1 m3) cylinder channel with nuts and bolts (single cylinder) 845122 350 ft.3 (9.9 m3), 425 ft.3 (12.0 m3), 435 ft.3 (12.3 m3) cylinder strap (single cylinder) 845245 350 ft.3 (9.9 m3), 425 ft.3 (12.0 m3), 435 ft.3 (12.3 m3) cylinder channel with nuts and bolts (single cylinder) 879638 Back frame assembly (2 cylinder) 879639 Back frame assembly (3 cylinder) 879640 Back frame assembly (4 cylinder) 879641 Back frame assembly (5 cylinder) 879642 Back frame assembly (6 cylinder) 873257 Upright, for 200, 250, 350, and 435 ft.3 (12.3 m3) cylinders (used either for right side, left side or center (center upright required when connecting seven or more cylinders in a row)) 426592 Upright, for 425 ft.3 (12.0 m3) cylinder (used either for right side, left side, or center (center upright required when connecting seven or more cylinders in a row)) 873553 Single row or back-to-back row bracket foot (left side) 873554 Single row or back-to-back row bracket foot (right side) 873555 Double row bracket foot (left side) 873556 Double row bracket foot (right side) 418508 Center upright foot 879413 Connector (required to hook together back frames for seven or more cylinders) 873250 10.5 in. (26.7 cm) carriage bolt with nut (for single row 200 ft.3 (5.7 m3) cylinders) 873251 11 in (27.9 cm) carriage bolt with nut (for single row 250 ft.3 (7.1 m3) cylinders) 873252 12.5 in. (31.8 cm) carriage bolt with nut (for single row 350 ft.3 (9.9 m3) and 425 ft.3 (12.0 m3) cylinders) 418502 13 in. (33.0 cm) carriage bolt with nut (for single row 435 ft.3 (12.3 m3) cylinders) 873253 - 21 in. (53.3 cm) carriage bolt with nut (for double row 200 ft.3 (5.7 m3) cylinders) 873254 22 in. (55.9 cm) carriage bolt with nut (for double row 250 ft.2 (7.1 m3) cylinders) 873255 26 in. (66 cm) carriage bolt with nut (for double row 350 ft.3 (9.9 m3) and 425 ft.3 (12.0 m3) cylinders) 418503 27 in. (68.6 cm) carriage bolt with nut (for double row 435 ft.3 (12.3 m3) cylinders) 873091 Cylinder clamp (2 cylinders) 873092 Cylinder clamp (3 cylinders) 871683 Weigh rail support - single row 871682 Weigh rail support - double row 871684 Weigh rail support - back-to-back rows 423027 Weigh rail support back-to-back double row I Multi-Cylinder Single Cylinder UPRIGHT BACK FRAME I - CYLINDER CLAMP CARRIAGE BOLT WITH NUT RIGHT BRACKET FOOT CW CLAMP II Ii • Ii Ii I LEFT BRACKET FOOT 771 ANSUL and INERGEN are trademarks of Ansul Incorporated or its affiliates. ANSUL INCORPORATED, ONE STANTON STREET. MARINETIE, WI 54143-2542 715-735-7411 Form No. F-9309-7 ©1999 Ansul Incorporated Litho in U.S.A. ANSUL System Components ULEX-4510 12-1-93 Page 1-23 0 hig. L19 a Warning Plate - Inside Room With Alarm Description The warning plate is available for mounting inside the haz- ard area to warn the personnel to vacate the hazard area when the alarm sounds. The warning plate is furnished with four mounting holes for ease of installation. The plate is constructed of aluminum. Shipping Assembly Part No. Description 416265 Warning Plate - inside room with alarm Component Material Mounting Hole Size Approvals Warning Plate Aluminum 1/4 in. (64 cm) FMRC Approved UL Listed (EX-4510) 12.00 fl WHEN ALARM SOUNDS . VACATE AT ONCE INERGENTM AGENT BEING RELEASED @U Li, LABEL NO. 416265 ANSUL and INERGEN are trademarks otAnsul Incorporated or its affiliates. ANSUL INCORPORATED, ONE STANTON STREET, MARINErrE, WI 54143-2542 715-735-7411 Form No. F-9315-2 (0)2000 Ansul Incorporated Litho in U.S.A. 7.00 002746 ANSUL IneVal Clean Ageet System Components UL EX-4510 5-1-00 Page 1-24 REV. 1 Warning Plate - Outside Room Without Alarm Description The warning plate is, available for mounting outside the haz- ard area to warn the personnel that the space is protected by an lNERGENm, system and no one should enter after a discharge without being properly protected. The warning plate is furnished with four mounting holes for ease of installation. Shipping Assembly Part No. Description 416266 Warning Plate - outside room Component Material Mounting Hole Size Approvals Warning Plate Aluminum 7/32 in. (.56 cm) FMRC Approved UL Listed (EX-4510) 8.00 0- WARNING THIS SPACE IS PROTECTED BY AN INERGEN® FIRE SUPPRESSION SYSTEM. WHEN SYSTEM IS DISCHARGED AS A RESULT OF FIRE, CAUTION MUST BE TAKEN TO AVOID EXPOSURE TO PRODUCTS OF COMBUSTION. DO NOT ENTER WITHOUT APPROVED SELF- CONTAINED BREATHING APPARATUS OR UNTIL VENTILATION HAS BEEN OPERATED FOR AT LEAST 15 MINUTES. LnSVn. () LABEL NO. 416266 0 ANSUL and INERGEN are trademarks of Ansul Incorporated or its affiliates. ANSUL INCORPORATED, ONE STANTON STREET. MARINEI1E, Vt 54143-2542 715-735-7411 Form No. F-9314-3 02000 Ansul Incorporated Litho in U.S.A. 7.00 002747 N ,1 CYLINDER AGENT I..X.. VALVE i SOURCE V N COIL SUPERVISORY MODULE MAINTENANCE SWITCH RAC RAC -IIIIIIIIIIIIIHIHHJHHIHIHIUIIIIIUIAHH!U SPM 2 ro rn •• Li -Lill AUTOPULSE Z-10 Agent Release Control Panel One-Line System Reference Drawing NAC I NAC 2 L] ANSUL DETECTION AND CONTROL EQUIPMENT DATA SHEET 0 FEATURES Agent Release Control Panel designed specifically for suppression release operation with: Four initiating device circuits (lDCs) Two notification appliance circuits (NACs) Two release appliance circuits (RACs) Two special purpose monitor inputs (SPMs) for manual release request and manual abort request Three auxiliary relays with selectable functions Easily selected activity timing options Agent release operation includes: Automatic extinguishing release Deluge and preaction sprinkler system release Dual or single hazard area protection IDCs are selectable for cross-zoning or for activation from a single detection input Operator interface provides: Status LEDs per circuit for Alarm, Trouble, and Supervisory (where appropriate) Acknowledge, alarm silence, and system reset Operating mode and timer selection when in programming mode Compatible with Listed/Approved 24 VDC coil automatic water control valves Required system components: Coil supervision module, Part No. 430687, one per solenoid control RAC Maintenance Switch, Part No. 76498 or 76499, one per solenoid control RAC Recommended accessory (where appro- priate): Abort Switch, Part No. 76494 or 76495 INTRODUCTION Dedicated for Agent Release. Z-10 Sup- pression Release Panels provide conven- tional fire alarm control circuits and are equipped with the features required for a wide variety of single or dual hazard suppression release applications. Capabili- ties include automatic extinguishing agent release and deluge and preaction sprinkler control. Flexible I/O Capabilities. Four lDCs allow for either four separately monitored zones or two, cross-zoned connections. Two SPMs allow dedicated manual inputs for release or abort. Two release appliance circuits (RACs) supervise to the valve coils and activate the valves when required. The two NAC circuits and the three panel auxiliary relays provide status condition information. Easy Program Selections. The operator panel has a program mode that allows selec- tion of panel operation type and detailed operating selections using an easily selected sequential programming operation. History Log. The last 50 events are stored in non-volatile memory. This information is accessed by connecting a technician's computer to the service port which is also used to set the date and time. PANEL FEATURE DESCRIPTION I AUTOPULSE Z-10 PRODUCT SELECTION Operator Panel. The operator panel has alarm and trouble status indicating LEDs for each input and output, visible through the locking cabinet door. Unlocking the door rovides access to the Acknowledge, Alarm ilence, and System Reset push-button Four Class B IDCs provide coverage for either two cross-zoned areas or four sepa- rately zoned areas. lOCs are capable of supporting up to 30 current-limited smoke detectors or electronic heat detectors as well as manual stations and other compatible contact closure initiating devices. lDCs are capable of Class A operation with an optional adapter module and can be programmed as Class C (short or open initiates a trouble) for use with current limited devices only. Two Class B Special Purpose Monitoring Circuits (SPMs) are available for monitoring of manual release or abort switch inputs only. Inputs are normally open switches. An abort switch stops release while activated and upon deactivation, the release operation occurs after a selectable time delay. Manual release inputs activate release after selec- table delays of from 0 to 30 seconds in 5 second increments. For Class B/A, Abort switches are assumed to be current limited. SPMs are programmable as style C and capable of Class A with the optional adapter module. Two Class B NACs. Rated 2 A, for reverse polarity notification appliance operation. Class A operation is available with optional adapter module. NAC operation is selectable per application. Two Class B Release Appliance Circuits Cs). Rated 2 A, these circuits are dedi- qFed to operating release control valves and ctuators. RAC cutout timing is selectable as no cutout, or 10, 15, or 20 minutes. Auxiliary Power Output. Rated at 750 mA, this output can be wired as continuous or as resettable. Resettable is normally used to power 4-wire smoke detectors. Standard Auxiliary Relay Outputs. Three relays outputs are available, selectable as normally open or normally closed, rated 2 A @3OVDC. Trouble Relay (Aux Relay 1) is energized When Normal and is de-energized with a Trouble condition. For Single Hazard Operation, Aux Relay 2 is the Alarm relay and Aux Relay 3 indicates Time Delay Started or can optionally be selected as a Supervisory relay. For Dual Hazard Operation, Aux Relay 2 is for Hazard Area 1 Alarm; Aux Relay 3 is for Hazard Area 2 Alarm, Power Supply and Battery Charger. During alarm, the power supply provides 3 A at 25.5 VDC, filtered and regulated. The temperature compensated battery charger provides 27.5 VDC for charging batteries suitable for up to 90 hour standby and 10 minutes of alarm. External battery chargers and cabinets can be used for more battery backup. RELEASE CONTROL PANEL Part No. Description Reference 430525 Basic Releasing Panel, operates Includes: Four lDCs, two NACs, with AC input of: two SPMs, two RACs, 3 A power 120/220/230/240 VAC, supply with battery charger, 50/60 Hz (auto-select) cabinet and door EXPANSION MODULES Part No. Description Reference 430529 Auxiliary Relay Module; four Two maximum relays, Form C, rated 7 A @ 120 VAC, 5 A @30 VDC, unsupervised contacts Select as 430531 Two Circuit Class A Adapter Four maximum required Module for lDCs, SPMs, or NACs Batteries Part No. Description Reference 417692 7.0 AH Battery Pack, 24 VDC Select one battery shipping assembly per system standby 417693 12 AH Battery Pack, 24 VDC requirements; two batteries are included 417694 17 AH Battery Pack, 24 VCD Requires external battery cabinet 417695 25 AH Battery Pack, 24 VDC 417997 50 AH Battery Pack, 24 VDC Release Control System Modules Part No. Description 430687 Coil Supervision Module, one required per RAC; refer to pages 6 and 7 for detail 76498 or 76499 Maintenance Switch, one required per RAC 76494 or 76495 Abort Switch, select as required 431196 Abort Supervision Module 16 IN. (483 mm) 006555 C BOX DEPTH 4-1/4 IN. (108 mm) 01 DOOR THICKNESS - 518 IN. (16 mm) MOUNTING REFERENCE INFORMATION S BOX WIDTH 14-5/8 IN. (372 mm) - - -. TYPICAL CONDUIT ENTRY AREA TOP AND SIDE VIEWS SHOWN (CUT HOLES AS REQUIRED) WITH DOOR INSTALLED) __________ (FRONT VIEW MODULE PLACEMENT REFERENCE SHOWING MOUNTING HOLE DIMENSIONS, OPTIONAL CLASS A ADAPTER MODULES, AND OPTIONAL RELAY MODULES) NOTE: FOR SEMI-FLUSH MOUNTING, CABINET MUST EXTEND 1-1/2 IN. (38 mm) MINIMUM FROM WALL SURFACE NOTE: A SYSTEM GROUND MUST BE PROVIDED FOR EARTH DETECTION AND TRANSIENT PROTECTION DEVICES. THIS CONNECTION SHALL BE MADE TO AN APPROVED, DEDICATED EARTH CONNECTION PER NFPA 70, ARTICLE 250, AND NFPA 780. 10 RELEASE CONTROL SYSTEM REFERENCE Automatic Agent Release Systems. These systems automatically activate solenoid control valves for the release of a fire extin- uishing agent (such as dry chemical, water pray, foam, CO2, or INERGEN) in response to fire detection device input UL and FM Agent Release System Panels must have a minimum of 24 hours of standby power. Initiating devices must be Listed/Approved for the application, and may be wired either Class A or B. Solenoid control valves must be electrically compatible with the control panel circuits and power supplies, and are wired Class B to provide coil supervision. Deluge and Preaction Sprinkler Systems automatically activate water control valves in response to fire detection device input. UL requirements for Fire Alarm Systems Listed for Automatic Release or Deluge and Preaction Sprinkler Systems are the same as described above for Automatic Extinguishing Release Systems. FM Approved requirements for Fire Alarm Systems for Automatic Release of Deluge and Preaction Sprinkler Systems require operation of specific compatible FM Approved Automatic Water Control Valves, a minimum secondary power capacity of 90 hours, and all circuits for the automatic release initiating devices must be capable of operation during a single open circuit fault condition (Class A). I Preaction Sprinkler Systems are similar to deluge systems except that normally closed sprinkler heads are used and supervisory air essure is maintained in the pipe. Operation quires both an activated sprinkler head and activated fire detector (or fire detectors). Deluge Sprinkler Systems employ open sprinkler heads and provide water flow when the fire detection system activates a common automatic water control valve. They are used to deliver water simultaneously through all of the system sprinkler heads. This type of system is applicable where the immediate application of large quantities of water over large areas is the proper fire response. RELEASE CONTROL SYSTEM REQUIREMENTS Solenoid valves are connected as 2- wire, Class B notification circuits with only one 24 VDC solenoid valve per circuit (or two, 12 VDC solenoids in series if applicable) to ensure supervi- sion. Coil Supervision Module, Part No. 430687, must be wired electrically before the solenoid valve and located in the solenoid valve wiring junction box.' For FM Approved Deluge and Preaction Sprinkler operation, initiating device circuits must be Class A, wired to Listed/Approved devices. Power supply loading and wiring distances must be per Installation, Programming, and Operating Instruc- tions, Part No. 430545. For FM Approved Deluge and Preaction Sprinkler Systems, battery standby capacity must be a minimum of 90 hours with 10 minutes of alarm. For FM Approved Automatic Extinguish- ing Release, battery standby must be a minimum of 24 hours with 5 minutes of alarm. Battery standby must be selected for a minimum voltage of 23 VDC to ensure proper valve operation. Maintenance Switch, Part No. 76498 or 76499, are required to ensure that notifi- cation circuits dedicated for release operation may be properly disabled prior to service. (Refer to NFPA 72, the National Fire Alarm Code, Section 3- 10.4, 1996 edition or Section 3-8.4.3.4, 1999 edition.) For FM Approved Deluge and Preaction Sprinkler operation, the specified compatible Automatic Water Control Valves must be used. For UL Listed and FM Approved Auto- matic Extinguishing Release, solenoid valves must be electrically compatible. Abort Switches, Part No. 76494 or 76495, are available when abort opera- tion is required. When used, wire on Special Purpose Monitoring Circuits (SPMs) as Class A or B, the same as required for other initiating devices. Manual Release Stations are used for direct activation of the release solenoids with the appropriate time delay imple- mented by the fire alarm control panel (typically 15 or 30 seconds). LISTINGS AND APPROVALS UL Listed FM Approved CSFM (Pending) MEA (NYC) (Pending) EXPANSION MODULES AND ACCESSORIES Auxiliary Relay Module, Part No. 430529. Four relays per module are available as required. Dual hazard applications will require two modules for auxiliary relay opera- tion. Each relay module has a manual disconnect switch that controls relays 2 through 4 (Trouble Relay is not controlled). Relay outputs are required to be connected to 15 A maximum circuit breaker. Operation is per the following actions: Relay I activates on any trouble associated with its hazard Relay 2 activates on any alarm associated with its hazard Relay 3 activates with the first zone of a cross-zoned system (hazard specific) Relay 4 activates when the hazard specific RAC activates Dual Circuit Class A Adapter Module, Part No. 430531. This module converts two Class B circuits to Class A operation. It consumes no additional current and is compatible with IDCs, SPMs, and NACs. Up to four modules may be mounted within the Z-10 cabinet. Maintenance Switch. Proper service of release appliance circuits requires the ability to securely disconnect the release circuit during installation and maintenance. This module provides a keyswitch on a stainless steel single gang plate with clear functional markings. (See following illustration.) Cs) 0 NORMAL (a LocK-ouT 0 FIRE SUPPRESSION SYSTEM ABORT 0 0 IZ Maintenance Switch 056549 Remote Battery Meter Module. For display of battery voltage and charge and discharge current. This module mounts within 3 ft (1 m) of the Z-10 cabinet using a four-gang electri- cal box. HHE ALM erEu B AT FAT UET[ fl H 0 Remote Battery Meter Module 006551 Abort Switch. For manual abort requests, a large pushbutton switch is provided. Activity abort occurs while the switch is pushed and continues after releasing the switch for the selected Abort Release Time Delay. (See illustration below.) FIRE SUPPRESSION SYSTEM ABORT 0 PUSH AND HOLD Abort Switch S 0 FM APPROVED WATER CONTROL VALVES FM Group Manufacturer Model Number Details A Skinner LV2LBX25 24 VDC, 11 W, 458 mA, 1/2 in. NPS, 1/2 in. orifice B ASCO T82 10A 107 24 VDC, 16.8 W, 700 mA, 1/2 in. NPS, 5/8 in. orifice R8210A107 8210A107 C Star Sprinkler 5550 24 VDC, part of Model 0 deluge valve 0 ASCO 8210G207 24 VDC, 10.6 W, 440 mA, 1/2 in. NPS, 1/2 in. orifice V2648571, N.C. HV2648581, N.O. E Skinner 73218BN4UNLVNQC111C2 24 VDC, 10 W, 420 mA, 1/2 in. NPS, 5/8 in. orifice 73212BN4TN00N0C111C2 24 VDC, 10 W, 420 mA, 1/2 in. NPS, 5/8 in. orifice; 5-300 psi rated working pressure F Skinner 73212BN41NLVN0C322C2 24 VDC, 22W, 1/2 in. NPS, 920 mA, 250 psi (1725 kPa),1/2 in. orifice G Skinner 71395SN2ENJ1N0H1I1C2 24 VDC, 10 W, 420 mA, 1/4 in. NPS, 1/16 in. orifice, 250 psi (1725 kPa) rated working pressure H Viking HV-274-060-001 24 VDC, 22.6 W, 940 mA, 1/2 in. NPS, 250 PSI (1725 kPa), 3/4 in. orifice SPECIFICATIONS Power Ratings AC Input Voltage Ratings Current Rating 120 VAC, 60 Hz; 220/230/240 VAC, 50/60 Hz, auto-select 2 A maximum @ 120 VAC input; 1 A maximum @ 240 VAC input Power Supply 3 A maximum @ nominal 24 VDC Battery Charger Temperature compensated, capable of recharging batteries required for 90 hour standby and 10 minute alarm Standard Circuit Ratings (NOTE: Total DC current = 3 A maximum) Notification Appliance Circuits (NACs) 2 A maximum @ 24 VDC, per circuit Release Appliance Circuits (RACs) 2 A maximum © 24 VDC, per circuit Initiating Device Supervisory Current Circuits (lDCs) Alarm Current Capacity 3 mA maximum 60 mA maximum Each IDC supports up to 30 detectors (smoke or electronic heat) and manual stations as required, wiring distance is limited to 50 Q maximum Special Purpose Monitoring Circuits (SPMs) For Manual Release or Abort switches only; not for detectors Auxiliary Power Output Two outputs are available, continuous operation or resettable operation; combined output is 750 mA maximum @ 24 VDC Auxiliary Relay Outputs (Trouble, Aux Relay 2, Aux Relay 3) Contacts rated 2 A @ 30 VDC, selectable as N.O. or N.C. by jumper Wiring Connections for Above Circuits and AC Input Terminals rated for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2 ) Auxiliary Module Ratings Class A Adapter Module, Part No. 430531 Two circuits per module, rated same as circuits (not applicable to RACs) (no additional current required) Relay Type Auxiliary Relay Module, AC Ratings Part No. 430529 DC Ratings Current Wiring Four relays with two outputs per, relay; individually selectable as N.O. or N.C. 7 A @ 120 VAC, rated for pilot duty @ 0.35 power factor 5 A @ 30 VDC, rated for pilot duty @ 0.35 power factor 70 mA @ 24 VDC, all four relays energized Terminals rated for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2 ) Coil Supervision Module Construction - - Epoxy encapsulated Dimensions 1-3/8 in. W x 2-7/16 in. L x 1-1/16 in. H (34 mm x 62 mm x 27 mm) Wiring 18 AWG (0.82 mm2) wire leads, color coded Current Rating 2 A Maximum Environmental Ratings Operating Temperature Range 32 to 120°F (0° to 49° C) Operating Humidity Range up to 93% RH, non-condensing @ 100.4° F (38° C) maximum REFERENCE INFORMATION, COMPATIBLE DETECTORS Part No. Type Description Data Sheet 430559 430562 Photoelectric smoke detectors for 2-wire bases Standard detector Reduced sensitivity detector F2002159 F-2002160 Combination smoke and heat detector 430565 430566 Electronic heat detectors for 2wire and 4-wire bases 135° F (57°C Fixed heat detector F-2002158 200° F (93°C) Fixed with rate-of-rise heat detector AUTOPULSE Z-10 SYSTEM CONNECTION REFERENCE ELECTRICALLY COMPATIBLE ACTUATOR OR COMPATIBLE FM APPROVED DELUGE AND PREACTION AUTOMATIC WATER CONTROL VALVE, ONE PER RAC A ACTUATOR WIRING JUNCTION BOX Yet BIk Red BI - ABORT SUPERVISION SUPERVISION MODULE COIL SUPERVISION MODULE MAINTENANCE SWITCH WITH LAMP RAC I ABORT SWrrcHES MANUAL RELEASE 24 VDC (AS REQUIR STATIONS SPM 1 TYPICAL STROBE ONLY NAC NAC I ;]) RAC _F1 R E 1lI MANUAL FIRE ALARM STATION j TYPICAL HORN ONLY NAC OMPATIBLE C DETECTION ____________________ NAC 2 DEVICES IDCS 2,3, AND 4 IME AUTOPULSE Z-10 SUPPRESSION 0D6553 RELEASE PANEL —j METER MODULE CABLE - - ---- (SUPPLIED WITH METER MODULE) OPTIONAL METER MODULE NOTE: LOCATE METER MODULE WITHIN 3 FT (1 M) OF Z-10 CABINET. GENERAL WIRING NOTE: WIRING SHOWN IS FOR REFERENCE ONLY, REFER TO SPECIFIC INSTALLATION INSTRUCTIONS FOR DETAILED WIRING INFORMATION. 4 PROGRAMMING MODES AND SELECTION CHOICES RELEASE CONTROL PANELS Sequence Programming Mode Description Choices 1 Application Mode Agent release or preaction deluge; single or dual hazard; cross-zoned, combined, cross-zoned and combined, or neither (9 choices) 2 lDC and SPM Circuit Style Class B/Class A or Style C 3 Automatic Release Time Delay 0, 10, 20, 30, 40, 50, or 60 seconds 4 RAC Cutout Timer No cutout, 10, 15, or 20 minutes 5 Manual Release Time Delay 0, 5, 10, 15, 20, 25, or 30 seconds 6 Abort Release Time Delay UL Standard 864 listed Immediate or 10 seconds remaining Not UL Standard 864 listed lRl abort (cross-zoned systems only), NYC abort, original release delay 7 NAC Coding (where selectable) Temporal pattern or 20 beats per minute 8 NAC Operation No inhibit or one minute inhibit selected as: both on until silence, NAC 1 on until silence and NAC 2 on until reset, or both on until reset 9 Supervisory Latching Latching or non-latching 10 Supervisory Notification LED and tone-alert only, or with: NAC 2 also on; Aux Relay 3 also on; or both NAC 2 and Aux Relay 3 also on OPERATOR PANEL FUNCTION REFERENCE LABEL INSERT SELECTABLE FOR PREACTION/DELLJGE OR AGENT RELEASE, UL OR ULC VERSIONS RUN MODE: LEDs PROVIDE ALARM (RED) AND TROUBLE (YELLOW) STATUS PER IDC ZONE PROGRAM MODE: TOP TEN LEDs INDICATE PROGRAMMING MODE CATEGORY ALARM SILENCED YELLOW LED INDICATES THAT AUDIBLE NOTIFICATION APPLIANCES ARE SILENCED PRIOR TO SYSTEM RESET SUPERVISORY AND SYSTEM TROUBLE YELLOW LEDs AC POWER GREEN LEO IS ON WITH NORMAL POWER STATUS ACK ACKNOWLEDGES ALARM SILENCE SYSTEM RESET RESTORES STATUS DURING RUN MODE SILENCES THE SYSTEM TO NORMAL AND ACCEPTS SELECTION AUDIBLE ALARMS DURING RUN MODE AND DURING PROGRAM MODE: TOGGLES THE SELECTION PRESS ANDHOLD FOR 5 DURING PROGRAM MODE SECONDS TO PERFORM LAMP TEST RUN MODE: RED LEDs INDICATE MANUAL RELEASE ACTIVATED (FOR AGENT RELEASE APPLICATIONS): YELLOW LEDs INDICATE TROUBLE FOR SPMs (ZONES 5 and 6), NACs, and RACs I PROGRAM MODE: TOP I EIGHT LEDs PROVIDE PROGRAMMING SELECTION --I [1 I AGENT RELEASED RED LEC INDICATE RACs ARE ACTIVATED I EARTH FAULT YELLOW LED I INDICATES PRESENCE OF I AN EARTH FAULT ABORT ACTIVE YELLOW LED TRACKS STATE OF ABORT SWITCH RELAY DISCONNECT YELLOW LED INDICATES THAT EXPANSION RELAYS HAVE BEEN DISABLED FOR SERVICE ANSUL® Detection and Control Components r 11' •....u....i IlURtI UU•U•UU .., Ir.-r a'l U •1r,u •.IU. r .. L .U•••L .l moke Detecto for 1 - Basel j Features Functional chamber enclosure: Louvered design enhances smoke capture by directing flow to chamber Entrance areas are minimally visible when ceiling mounted Alarm indicator LED: Pulses to indicate power-on On steady to indicate alarm Functional diagnostic tests: Magnetic test initiates alarm and verifies system operation Service connections are available for sensitivity verification testing Available base options: Bases for 2-wire operation Auxiliary alarm relay output Remote alarm indicating LED output Optional remote alarm LED indicator Description For applications requiring ionization detection, the detector, Part No. 430561, provides conventional dual-chamber detection in an attractive housing. Bases are available for 2-wire operation. A built-in magnetic test feature allows service personnel to conveniently initiate a test alarm condition. Options include relay outputs and remote LED alarm status indicators. Listings and Approvals UL Listed ULC Listed FM Approved CSFM Approved MEA (NYC) Approved -__ Ionization Detector Mounted in Base Application Reference Detector Locations. Locations should be determined only after careful consideration of the physical layout and contents of the area to be protected. For further detailed installation information, refer to Detectors, Sensors, and Bases Application Manual, Part No. 431424. Specifications Voltage 8.5 to 33 VDC, from fire alarm control panel Initiating Device Circuit (IDC) Standby Current 80 l.JA @ 24 VDC Alarm Current, Up to 86 mA maximum, 2-Wire Operation exact current is determined by alarm current limiting of connected IDC Sensitivity Level 0.61 to 1.46%/ft Radioactive Source 0.9 Microcurie AM-241 Air Velocity Range 0-100 ft/mm (0-30 rn/mm) Altitude Up to 8000 ft (2438 m) UL Listed 32° Fto 100° F Temperature Range (0° C to 38° C) Operating 32° F to 122° F Temperature Range (0° C to 50° C) Humidity Range 10% to 95% RH from 32° F to 122° F (0° Cto50° C) Color Frost White Dimensions Refer to diagram on page 2 S I C Product Selection Smoke Detectors Part No. Description Compatibility 430561 Ionization Smoke Compatible with detector 430697 Detector bases: Part No. 430567 (ULC) and 430569 Detector Bases Part No. Description Details 430567 2-Wire Base with IDC and LED connections connections for are screw terminals for Remote Alarm in/out wiring, LED Indicator 18 to 14 AWG 430569 2-Wire Base Relay Ratings, Dual Form with Auxiliary "C", For Suppressed Alarm Relay Loads: and connections Power limited, 1 A @ for Remote 28 VDC LED Indicator Non-power limited, 1/2 A @ 120 VAC NOTE: Must be Wiring Connections (In/Out connected as the where required): only device on the Relay contacts and IDC (-), IDC to ensure color coded 18 AWG leads relay operation. IDC (+) and LED wiring, screw terminals for 18 to 14 AWG Detector Accessories Part No. Description Details 430646 Adapter Plate Required for mounting to surface mounted boxes and 4 in. square, flush mounted box May be used when retro- fitting existing bases Compatible with Part No. 430567 and 430569 detector bases 430572 Remote LED Mounted on single gang Indicator stainless steel plate Metric wire equivalents: 18 AWG = 0.82 mm2; 14 AWG = 2.08 mm2 Mounting Information ELECTRICAL BOX REQUIREMENTS: WITHOUT RELAY (BASE, PART NO. 430567): 4 IN. OCTAGONAL OR 4 IN. SQUARE, 11/2 IN. DEEP SINGLE GANG, 2 IN. DEEP WITH RELAY (BASE, PART NO. 430569): 4 IN. OCTAGONAL, 1 1/2 IN. DEEP, WITH 1 1/2 IN. EXTENSION RING 4 IN. SQUARE, 11/2 IN. DEEP, WITH 11/2 IN. EXTENSION RING 4 IN. (102 mm) SURFACE MOUNT REFERENCE OCTAGONAL BOX /T04 c 2TTTTTT0 T' - 4 IN. (102mm) SQUARE BOX FLUSH MOUNT REFERENCE, MOUNT EVEN WITH FINAL 11/2 IN. (38 mm) SURFACE, OR WITH UP TO 1/4 IN. (6.4 mm) MAXIMUM RECESS MINIMUM BOX DEPTH ADAPTER PLATE, PART NO. 430646, REQUIRED FOR MOUNTING TO SURFACE MOUNTED BOXES AND TO 4 IN. SQUARE FLUSH MOUNT BOXES PART NO. 430569 INCLUDES A RELAY MODULE THAT MOUNTS IN BASE ELECTRICAL BOX SMOKE DETECTOR BASES, PART NOS. 430567 AND 430569 006566 SMOKE DETECTOR, PART NO. 430561 Detector and Base Dimension Reference I-i 47/81N. (124 mm) rL 1718 IN. BASE HEIGHT 11/16 IN. ______ na 006585 LED STATUS INDICATOR (WITH CLEAR LENS) 0 ANSUL and AUTOPULSE are trademarks of Ansul Incorporated or its affiliates. ANSUL INCORPORATED, ONE STANTON STREET. MARINEnE, Wi 54143-2542 715-735-7411 Form No. F-2002161 02003 Ansul Incorporated Litho in U.S.A. 006564 LiFEalarm Photoelectric Detector Mounted in Base Listings and Approvals UL Listed ULC Listed FM Approved CSFM (Pending) MEA (NYC) (Pending) Specifications Voltage 15 to 32 VDC, from Control Panel IDC Standby Current 100 pA @24 VDC Alarm Current, Up to 86 mA maximum, exact 2-Wire Operation current is determined by alarm current limiting of connected IDC Auxiliary Relay Ratings Refer to page 2 under Product Selection Air Velocity Range 0-2000 ft/mm (0-610 rn/mm) UL Listed Temp. Range 320 to 100° F (0° to 38° C) Operating Temp. Range 150 to 122° F (-9° to + 50° C) Humidity Range 10% to 95% RH from 32° to 122° F (0° to 50° C) non-condensing Color Frost White Dimensions 4 7/8 in. Dia. x 1 7/8 in. H, mounted in base (124 mmx 48 mm) ANSUL® Detection and Control Components LiFEalarme Photoelectric Smoke Detectors For Two-Wire Bases Features LiFEalarm® Photoelectric smoke detector with on-board sensitivity drift compensation* Functional chamber enclosure: Louvered design enhances smoke capture by directing flow to chamber Entrance areas are minimally visible when ceiling mounted Multi-function indicator LED indicates normal and alarm conditions Magnetically operated functional test: Initiates alarm and verifies performance Identifies general sensitivity status using detector LED Models available in two sensitivity settings: Part No. 430559 (Part No. 430695 ULC), Standard Sensitivity, nominal 2.8%/ft obscuration . • Part No. 430562, Special Application Sensitivity, nominal 3.5%/ft obscuration Available base options: Bases for 2-wire operation Auxiliary alarm relay output Optional remote alarm indicating LED Description LlFEalarm photoelectric detectors provide many of the proven analog sensing features for applications where detectors are connected to conventional 2-wire initiating device circuits (lDCs). Each detector has an on-board micro- processor that evaluates its photoelectric light scattering chamber activity and makes an intelligent decision based on light obscuration history as to whether an alarm condition is present. LlFEalarm detectors are packaged in a patented housing that minimizes the visibility of the air intake louvers from the normal viewing-locations While maintaining a high perfor- mance smoke capture ability. Bases are available for remote alarm LED indicator connections and auxiliary relay outputs. LlFEalarm smoke detector operation is protected by one or more of the following U.S. Patents: 5,155,468; 5,173,683; 5,400,014; 5,543,777; 5,710,541; 0383,407; 0388,352; 0392.573. 0 Smoke Detector Features Intelligent Data Evaluation. Conventional smoke detectors will typically drift toward being too sensitive due to the accu- mulation of dust and dirt. With analog detection, data from the photoelectric chamber is monitored and analyzed at the detector to provide a continuously shifting reference point. Drift Compensation. The data evaluation and its shifting reference point provide a software filtering process that compensates for environmental factors (dust, dirt, etc.) and component aging, establishing an accurate reference for evaluating new activity. With this filtering, the resulting drift compensation provides a significant reduction in the proba- bility of false or nuisance alarms caused by shifts in sensitiv- ity - either up or down. Magnetic Test Information. Status information is available by performing the magnetic test and observing the detector LED pulses. The LED will normally go directly into alarm with the magnetic test. If there is an off-normal condition, the LED pulses first to indicate the condition and then goes into alarm. Application Reference Detector Locations. Locations should be determined only after careful consideration of the physical layout and contents of the area to be protected. For further detailed installation information, refer to Detectors, Sensors, and Bases Application Manual, Part No. 431424. Sensitivity Selection. The standard sensitivity detector, Part No. 430559, is recommended for most applications. When a special application for a reduced sensitivity detector is required, Part No. 430562 should be considered. Consult Ansul for assistance in determining the proper selection. Product Selection Smoke Detectors Part No. Description Nominal Sensitivity Compatibility 430559 and 430695 (ULC) LlFEalarm Photoelectric Detector 2.8%/ft (standard) Compatible with detector bases: Part Nos. 430567 and 430569 430562 3.5%/ft Compatible Bases Part No. Description Details 430567 2-Wire Base with connections for IDC and LED connections are screw terminals for 430701 (ULC) Remote Alarm LED Indicator in/out wiring, 18 to 14 AWG 430569 2-Wire Base with Auxiliary Alarm Relay Relay Ratings, Dual Form "C', For Suppressed Loads: 430702 (ULC) & connections for Remote LED Indicator Power limited, 1 A @ 28 VDC NOTE: Must be connected as the only device Non-power limited, 1/2 A @ 120 VAC on the lDC to ensure relay operation. Wiring Connections (In/Out where required): Relay contacts and I DC (-.), color coded 18 AWG leads 430570 2-Wire Base with Remote LED Indicator 430703 (ULC) lDC (4-) and LED wiring, screw terminals for 18 to 14 AWG 430572 Remote LED Alarm Indicator 430704 (ULC) Detector Accessories Part No. Description Details 430646 Adapter Plate Required for mounting to 4 in. square box, fits 4 in. - octagonal box May be used when retrofitting existing bases Compatible with Part No. 430567 and Part No. 430569 detector bases 430572 Remote LED Indicator Mounted on single gang stainless steel plate Detector Status LED Indications LED Indication Status Pulses approximately every 4 seconds Normal Steady On Alarm LED Response to Magnetic Test * LED Indication Followed By Status Action LED turns ON Alarm is initiated Normal, sensitivity is within compensation range None LED pulses quickly, 6 times in 3 seconds, then turns ON Alarm is initiated More sensitive, out of normal compensation range Cleaning or other service is required LED pulses slowly, 4 times in 8 seconds, then turns ON Alarm is initiated Less sensitive, out of normal compensation range Does not initiate Alarm Detector is malfunctioning Service is required Testing requires placing a magnet at the designated location on the detector cover for 4 seconds. Refer to Application Manual, Part No. 431424, for further test and maintenance information. Dimensions and Reference Information 1/4 IN. __________________________________________ 6 3/8 IN. (6.4 mm) - (162 mm) _J1! OPTIONAL ADAPTER PLATE, PART NO. 430646 (REQUIRED FOR 4 IN. SQUARE BOX) 4 7/8 IN. (124 mm) BASE HEIGHT 1 7/8 IN. 11/16 IN. (17 mm) I . (48 mm) :-ff W6565 - LED STATUS INDICATOR (WITH CLEAR LENS) PART NO. 430559 AND PART NO. 430562 DIMENSIONS MOUNTED ON BASE 0065S1 REMOTE RED LED INDICATOR, PART NO. 430572 (NOT TO SCALE) Mounting Information ELECTRICAL BOX REQUIREMENTS; WITHOUT RELAY (BASE, PART NO. 430567): . 4 IN. OCTAGONAL OR 4 IN. SQUARE, 11/2 IN. DEEP SINGLE GANG, 2 IN. DEEP WITH RELAY (BASE, PART NO. 430569): 4 IN. OCTAGONAL, 11/2 IN. DEEP, WITH 11/2 IN, EXTENSION RING 4 IN. SQUARE, 11/2 IN. DEEP, WITH 11/2 IN. EXTENSION RING SURFACE MOUNT RFEFPFNrF 4 IN. (102 mm) OCTAGONAL BOX 1 1/2 IN. (38 mm) MINIMUM BOX DEPTH 0 LcL FLUSH MOUNT REFERENCE, MOUNT EVEN WITH FINAL SURFACE, OR WITH UP TO 1/4 IN. (6.4 mm) MAXIMUM RECESS 4 IN. (102 mrs SQUARE BO) ADAPTER PLATE, PART NO. 430646, REQUIRED FOR MOUNTING TO SURFACE MOUNTED BOXES AND TO 4 IN. SQUARE FLUSH MOUNT BOXES PART NO. 430569 INCLUDES A RELAY MODULE THAT MOUNTS IN BASE ELECTRICAL BOX SMOKE DETECTOR BASES, PART NOS. 430567 AND 430569 IS II) 1kr7 006566 SMOKE DETECTOR, PART NOS. 430559 AND 430562 *ANSUL and AUTOPULSE are trademarks of Ansul Incorporated or its affiliates. ANSUL INCORPORATED, ONE STANTON STREET, M.ARINETFE, WI 54143-2542 715-735-7411 Form No. F-2002159 (02003 Ansul Incorporated Litho in U.S.A. 31/4 IN. (83 mm) 31/4 IN. _—(83 mm) OO4648 PULL STATION (95 mm) 33/4 IN. (95 mm) 006753 2-1.06 3-32 STANDARD PULL STATION 7/8 IN. (22 mm) 411/16 IN. (119 mm) 31/4 IN. (83 mm) WEATHERPROOF PULL STATION ANSUL r u•' •u.aur-.uuea ... Ir-iu-r i- -. •i i-lri ••V ii U 1 U I .S. 1 -. .1. I II I S uuu•uu•• .l. 'U IU . ....% 9.UU•U.III.L4U lIUUUU•lUUUUI.UUUUUUI............, Detection and Control Components Electric Manual Pull Station Features UL Listed/FM Approved Approved for ADA Dual action Die-cast metal construction Terminal block Optional auxiliary contacts Flush mounts on single gang box Surface mount back box available Weatherproof back box available High-gloss red enamel finish Customized labels Keyed to match AUTOPULSE@ control units Applications The Electric Manual Pull Station is a cost-effective, feature- packed, non-coded manual fire alarm pull station. It was is designed to meet multiple applications with the installer and end-user in mind. The pull station provides the AUTOPULSE control panels with an alarm initiating input signal. Its innovative design, durable construction, and multiple mounting options make the pull station simple to install, maintain, and operate. Description The Electric Manual Pull Station is a high-quality, die-cast metal, dual action fire alarm pull station available with a SPST, DPST or DPDT switch with terminal strip connections. The contacts are rated for 1 Amp at 30 VDC. Gold plating on the contacts avoid the risk of corrosion. All models in the series have been tested by UL for compliance to the latest requirements of the American with Disabilities Act (ADA). The Electric Manual Pull Station is operated by pushing in the top bar and pulling the handle on the front of the station as far down as it will go. At this point, the handle locks into place and is easily visible from up to 50 ft. (15 m). Opening the station with the key, placing the handle in the normal upright position and re-locking the station resets the pull station. The addressable ready pull station comes with a bracket on the back for securing the FMM-101 Mini Monitor Module, Part No. 428098 (sold separately). The terminal block pro- vides clamping plates for easy connection to the SLC loop and N.O. switch contacts. An end-of-line resistor for the AUTOPULSE IQ-301 and AUTOPULSE IQ-396X is factory installed across the switch contacts. WIRING - SPST PULL STATION L1'iJ TOAUTOPULSE TO NEXT CONTROL UNIT DEVICE EOLR 004920 WIRING - DPST PULL STATION I-----1 -----1 TEOI EOLR II I lI I -- TOAUTOPULSE TO NEXT CONTROL UNIT DEVICE 004929 WIRING - EXPLOSION PROOF PULL STATION ' --1 I©I©II I IJ ' I LL I I I I L 1 TOAUTOPULSE TO NEXT EOLR CONTROL UNIT DEVICE 004930 WIRING -ADDRESSABLE READY PULL STATION FMM-101 TECHNICAL INFORMATION Conventional Switch Ratings: ....................... 1 A @ 30 VDC 1A@12OVAC Switch Type: .......................... SPST or DPST Terminal Size: . ........................Up to 14 AWG Color ...............Red with raised white letters, white PUSH/PULL HANDLES with raised red letters Weather Proof with Weather Proof Back Box ... NEMA 3R Explosion-proof Switch Ratings: ......................1 A @ 30 VDC, 10A@ 120 VAC Switch Type ................................DPDT Terminal Size: ........................Up to 14 AWG Humidity ..............90% Relative at 100°F (37.7 °F) Explosion Hazard Classifications: . Class I Groups B, C, D; Class II Groups E, F, G; Class Ill Weatherproof Classifications: ............ NEMA Type 4X Other Classifications ................UL Marine Listing Conduit Fittings .................................2 Conduit Fitting Size: .................. 3/4 in. - 14 NPT Color ..............Red with raised white letters, white PUSH/PULL handles with raised red letters LISTINGS AND APPROVALS* UL........................................S5654 UL (Explosion-proof Model) .................E 192508 ULC.......................................Listed Factory Mutual ...........................Approved California State Fire Marshal (CSFM) ......7150-1408:107 MEA....................................382-94-E Listhgs arid Appronts are under Sigrnd Conununications Corporation ORDERING INFORMATION Shipping Part Weight No. Description ik 428655 Manual Pull Station, SPST 1 (0.45) 428656 Manual Pull Station, DPST 1 (0.45) 428657 Explosion Proof Manual Pull Station 1 (0.45) 428658 Manual Pull Station, 1 (0.45) 11- Addressable Ready 428659 Weatherproof Back Box 1 (0.45) 428660 Surface Back Box . 1 (0.45) 428661 Break Rod 1 (0.45) 418336 Key 1 (0.45) 428654 Label Packet 1 (0.45) '41.1 YELLOW TOAUTOPULSE IS EOLR 10-301 or I0-396X - 0 ANSUL and AUTOPULSE are trademarks of Afoul Incorporated or its affiliates. TYCO SAFETY PRODUCTS. MARINETFE, WI 54143-2542 715-7357411 Form No. F-2001032-1 02006AnsuI Incorporated 004931 SURFACE-MOUNT ANSUL® 11llrr'9IUrllll I . I iI '• irr i- U V 8l I Al fig II ui Detection and Control Components Abort Switch Features Stackable, screw-terminal, contact blocks Compatible with AUTOPULSE® control units Surface-mount assemblies listed by Underwriters Laboratories, Inc. Components mounted on stainless steel switch plate Applications The Abort Switch is used to momentarily interrupt the release circuit signal when the control unit is in the alarm condition. As long as the abort pushbutton is held in, the fire suppres- sion system will not release. (Note: When the control unit is programmed for IRl compliance, the abort will not be effec- tive after pre-discharge.) When the pushbutton is released, the release circuit is activated (unless the control unit has been reset to the non-alarm condition). Description The Abort Switch assembly consists of a momentary- contact pushbutton switch, normally-open contact block, normally-closed contact block, and stainless steel switch plate with silk-screened label. Surface-mount assemblies include a single-gang weather-proof box with three 1/2 in. I.P.S. threaded conduit outlets and gasket. The stackable, screw-terminal contact blocks are rated for 28 VDC @ 1.1 amp make/break or 6 amp continuous carry. Listings and Approvals The switch is UL listed (S3623) when installed in the surface- mount box (with gasket) that is provided with the surface- mount assembly. MOUNTING DIMENSIONS TYPICAL WIRING DIAGRAMS ABORT SWITCH (SERIES) ----- SOL RESISTOR I- -Ø / '----I -Ø(-) I j CONTROL UNIT ABORT C IRCU Fr N.C. ABORT SWITCH LTSRMINALS- ABORT SWITCH (PARALLEL) EOL RESISTOR I L ' ( YI i—I I I CONTROL UNIT N.C. ABORT ABOATCIRCUIr SWITCH LM SEE CONTROL UNIT MANUAL FOR SPECIFIC WIRING REQUIREMENTS. 003735 Ordering Information Shipping Weight Part No. Description lb. (kg) 76494 Abort Switch, Surface-Mount 1.0 (0.45) 76495 Abort Switch, Flush-Mount 1.0 (0.45) 76485 Extra Contact Block, N.C. 0.25 (0.11) 76486 Extra Contact Block, N.O. 0.25 (0.11) ANSUL and AUTOPULSE are trademarks of Ansul Incorporated or its aft/isles. 2 7/8 IN. Th73 mm) 'J 0 ANSLfl- FIRE SUPPRESSION SYSTEM ABORT 0 4,W IN. (117 mm) PUSH AND HOLD 0 TYCO SAFETY PRODUCTS, MARINETTE, WI 54143-2542 716-735-7411 FLUSH-MOUNT 23/8 IN. -I (60 mm) E' 007362 Forts No. E95111 3-34 (6)1995 Ansul Incorporated Part No. Description 76498 Maintenance Switch, Surface-Mount 76499 Maintenance Switch, Flush-Mount 76485 Extra Contact Block, N.C. 76486 Extra Contact Block, N.O. 78179 Spare Key 470273 Extender-Back Box Shipping Weight Lb. (kg) 2.0 2.0 0.25 0.25 0.25 0.25 FLUSH-MOUNT 23/4 IN. (70 mm) " Ej_.' 007361 SURFACE-MOUNT ANSUL® Detection and Control Components UU•' 'U•UU•IUUUUU iUi.0 Ii••U•U•U r i 'I •9 Ir,: U A ii U I ,. 111 Iii .r LIlU U•'...iIUUi'UiUIIU!JiiI._I..dU UI fl % U .• !.NUNN"" Key Maintenance Switch Features Stackable, screw-terminal, contact blocks Compatible with AUTOPULSE® control units Surface-mount assemblies listed by Underwriters Laboratories, Inc. Components mounted on stainless steel switch plate Applications The Key Maintenance Switch is used to interrupt the release circuit signal to the fire suppression system. It is key-operat- ed to allow authorized personnel to deactivate the release circuit during service or maintenance. An indicator lamp, located on the switch plate, will light when the switch is in the "sock-out" mode to serve as a reminder that the release cir- cuit has been disconnected. Description TYPICAL WIRING DIAGRAM KEY-OPERATED CONTROL UNIT 24 VDC LOCK-OUT SWITCH RELEASE CIRCUIT ACTUATOR -T TERMINALS A 4 I :!JC JI NO _ N I POLARITY IS 1+•. I I I I SHOWN IN ALARM I 24 VDC POWER CONDITION SOURCE - - 24 VDC INDICATOR LAMP - SEE CONTROL UNIT MANUAL FOR SPECIFIC WIRING REQUIREMENTS. Ordering Information The Key Maintenance Switch assembly consists of a key- operated switch, 24 VDC indicator lamp, normally-open con- tact block, normally-closed contact block, and stainless steel switch plate with silk-screened label. Surface-mount assem- blies include a double-gang weather-proof box and gasket. The stackable, screw-terminal contact blocks are rated for 28 VDC © 1.1 amp make/break or 6 amp continuous carry. Listings and Approvals The switch is UL listed when installed in the surface-mount box (with gasket) that is provided with the surface-mount assembly. MOUNTING DIMENSIONS 411/16 IN. (119 mm) 0 0 NORMAL 00 ANSUL FIRE SUPPRESSION SYSTEM ABORT 0 0 ANSUL and AUTOPULSE are trademarks of Ansul Incorporated or Its affiliates. 3-33 TYCO SAFETY PRODUCTS, MARINEITE, WI 54143-2542 715-735-7411 Form No. F-95110-1 02003AnsuI Incorporated ake ActoriM SYSTEMS rr •MEA40 's'J FIRE ALARM ... & / 11111waL SPL..t i .FIRE® A Family of MuItiCandèta AppIiances SERIES AS SINGLE & MULTI-CANDELA AUDIBLE STROBE APPLIANCES SERIES AH AUDIBLES Description Wheelock's patented 2-wire Series AS Audible Strobe Appliances and Series AH Audibles offer more features with low current draw. Strobe options for wall mount models include 15/75cd or Wheelock's patented Multi-Candela strobe with field selectable candela settings of: 15, 30, 75 or llOcd. S S Ceiling mount models incorporate Wheelock's patented multi-candela ceiling strobe with field selectable intensities of 15, 30, 75 or 95cd. The audible provides a selectable choice of either a continuous horn or temporal pattern (Code 3) when constant voltage from a Fire Alarm Panel (FACP) is applied. Each tone has 3 dBA settings to choose from. Additionally, the audible may be silenced while maintaining strobe activation. All models may be synchronized when used in conjunction with the Wheelock SM, DSM Sync Modules or the PS-12/24-8 Power Supply with Wheelock's Patented Sync Protocol. Synchronization of the continuous horn tone provides the temporal (Code 3) tone as mandated by NFPA-72 for evacuation signaling. This ensures a distinct temporal (Code 3) pattern when 2 or more audibles are within hearing distance. If not synchronized, the temporal sound may overlap and not be distinctive. At the same time, the strobes will also be synchronized. This provides the ability to comply with ADA recommendations concerning photosensitive epilepsy and NFPA and UFC standards.when installing two or more visual appliances within the field of view. All of this, plus the ability to silence the audible is achieved by using only 2 WIRES. For Weatherproof Series AS, See Datasheet S9004 Copyright 2003 Wheelock Inc. All rights reserved. SERIES AS SERIES AH Multi-Candela Indicator (bottom of lens) Features Approvals include: UL Standard 1971, UL Standard 464 New York City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM), and Chicago (BFP). See approvals by model in Specifications and Ordering Information. ADAINFPA/UFC/ANSI Compliant Wall mount models are available with Field Selectable Candela Settings of 15, 30, 75 or llOcd (Multi-Candela models) or 15175cd (single candela models) Weatherproof models are available for outdoor use (ASWP) Ceiling mount models are available with field selectable candela settings of 15, 30, 75, or 95cd (multi-candela ceiling models) Selectable Continuous Horn or Temporal (Code 3). 3 Selectable dBA settings (99, 95 and 90 dBA) in both tones Patented 2-Wire Audible Strobe Appliance. Patented Universal Mounting Plate Strobes produce 1 flash per second over the regulated voltage range 12 and 24 VDC models with wide UL "Regulated Voltage Range" using filtered DC or unfiltered FWR input voltage Wall Mount or Ceiling Mount models Synchronize with Wheelock SM, DSM or PS-12/24-8 Power Supply with Wheelock's built-in sync protocol Compatible with all Wheelock 2-Wire products Fast installation with IN / OUT screw terminals using #12 to#18AWG wires Table 3: Average Mean Current° Series AH-24-RIW & AH-12-Rm & WP (Horn only) VOLTAGE High Medium Low 16.0 VDC .035 .020 .014 24.0 VDC .050 .026 .017 33.0 VDC .069 .035 .021 8.0 VDC .093 .037 .030 12.0 VDC .108 .049 .035 17.5 VDC .128 .069 .042 - Table 4: Average RMS Current * Series AS-241575 VOLTAGE High Medium Low 16.0 VDC .130 .114 .108 24.0 VDC .107 .085 .075 33.0 VDC .105 .075 .060 Table 7: Average Mean Current* Series AS-I21575 VOLTAGE High Medium Low 8.0 VDC .320 .275 265 12.0 VDC .250 .195 .175 17.5 VDC .205 .150 .130 *Average RMS Current is per UL average method and Average Mean Current is per UL average mean method. For rated In Rush and Peak current across the UL listed voltage range for both filtered DC and unfiltered VRMS (FWR), see installation instructions. ** Refer to Data Sheet S7000 for Mounting Options. NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY .DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes Strobes are designed to flash at 1 flash per second minimum over the Regulated Voltage Range. Note that NFPA-72 (1999) specifies a flash rate of 1 t 2 flashes per second and ADA Guidelines specify a flash rate of 1 t 3 flashes per second. All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. Series AS Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32° F to 120° F (0° C to 49° C) and maximum humidity of 93% (12%). Series AH-24 horns are listed under UL Standard 464 for audible signal appliances (Indoor use only). Series AH-24WP audible appliances are listed under UL Standard 464 for indoor/outdoor use with a temperature range of -31°F to 150°F (-35°C to 66°C) and maximum humidity of 95%. "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change, UL used the terminology "Listed Voltage Range". Table 1: Ratings Per uL 1971 Table 6: dBA Ratings for 12 voc and 24 VDC Series AS/AH 12 and 24 voc Audible Model Input Voltage VDC Regulated Voltage Range VOC/FWR Strobe Candela (Cd) Description Volume Reverberant dBA Per UL 464 @ 10 ft. Aneohoic dBA @ 10 ft. AS-24MCW-FR 24 16.0-33.0 15/30/75/110 Contiro is Horn High 91 99 AS-241575W-FR 24 16.0-33.0 15 (75 on Ads) Mediirn 88 95 AS-121575W-FR 12 8.0-17.5 15 (75 on Ads) Low 90 83 Code 3 Horn High 87 99 AS24MCC.FW 24 16.0-33.0 115/30/75/95 Meditin 84 95 ASWP-2475W-FR 24 16.0-33.0 75 @ -31°F Low 79 90 -- LiJ Table 2: Average RMS Current * for AS-24 MOW Wall Models @ Each Candela Setting Average Current-with High dBA Setting (99 dBA) Voltage 115cd 30cd 750d 110cd 16.0 VDC .099 .135 .219 .303 24.0 VDC .093 .114 .157 .197 33.0 VDC .098 .108 .138 .166 Average Current-with Medium dBA Setting (95 dBA) 16.0 VDC .078 .116 .203 .282 24.0 VOC .065 .088 .133 .179 33.0 VDC .065 .078 .106 .134 Average Current-with Low dBA Setting (90 dBA) 16.0 VDC .070 .111 .201 .279 24.0 VDC .052 .077 .126 .169 33.0 VDC .046 .063 .094 .121 Table 6: Average RMS Current ° for AS-24 MCC Ceiling Models Each Candela Setting Average Current-with High dBA Setting (99 dBA) Voltage 15cd 30cd 75cd 95cd 16.0 VDC .105 .145 .226 .314 24.0 VDC .097 .120 .161 .202 33.0 VDC .101 .113 .139 .168 Average Current-with Medium dBA Setting (95 dBA) 16.0 VDC .084 .126 .222 .309 24.0 VDC .069 .094 .145 .195 33.0 VDC .068 .083 .114 .145 Average Current-with Low dBA Setting (90 dBA) 16.0 VDC .076 .121 .220 .306 24.0 VDC .056 .084 .138 .185 33.0 VDC .049 .068 .102 .132 SYNC MODULESIPOWER SUPPLY Input Average Model Number Order Voltage Current Mean Mounting Code @ Options" 24 VDC SM-12/24-R' 6369 24 .028 W DSM-12t24-R" 6374 24 .035 W PS-12/24-8 8114 120 VAC - - #SM Sync Module is rated for 3.0 amperes @ 24 VDC. ##DSM Sync Module is rated for 3.0 amperes per circuit. The maximum number of interconnected DSM modules is twenty (20). Refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. ###Refer to Data Sheet S9001 or Installation Instructions P83862 for PS- 12/24-8 Power Supply. E] A WARNING: CONTACT WHEELOCK FOR THE CURRENT "INSTALLATION INSTRUCTIONS" (P83947) SERIES AS-24MCW, (P84023 AND P84024) SERIES AS SINGLE CANDELA, (P83519) Sejes AH, (P83641) Series AH-WP AND 'GENERAL INFORMATION" SHEET (P82380) ON THESE PRODUCTS, THESE DOCUMENTS UNDERGO PERIODIC CHANGES. IT IS IMPORTANT THAT YOU HAVE CURRENT INFORMATION ON THESE PRODUCTS. THESE MATERIALS CONTAIN IMPORTANT INFORMATION THAT SHOULD BE READ PRIOR TO SPECIFYING OR INSTALLING THESE PRODUCTS, INCLUDING: TOTAL CURRENT REQUIRED BY ALL APPLIANCES CONNECTED TO SYSTEM SECONDARY POWER SOURCES. FUSE RATINGS ON NOTIFICATION APPLIANCE CIRCUITS TO HANDLE PEAK CURRENTS FROM ALL APPLIANCES ON THOSE CIRCUITS. ADDING REPLACING OR CHANGING APPLIANCES OR CHANGING CANDELA SETTINGS WILL AFFECT CURRENT DRAW. RECALCULATE CURRENT DRAW TO INSURE THAT THE TOTAL AVERAGE CURRENT AND TOTAL PEAK REQUIRED BY ALL APPLIANCES DO NOT EXCEED THE RATED CAPACITY OF THE POWER SOURCE OR FUSES. COMPOSITE FLASH RATE FROM MULTIPLE STROBES WITHIN A PERSON'S FIELD OF VIEW. THE VOLTAGE APPLIED TO THESE PRODUCTS MUST BE WITHIN THEIR "REGULATED VOLTAGE RANGE". INSTALLATION OF 110 CANDELA STROBE PRODUCTS IN SLEEPING AREAS. INSTALLATION IN OFFICE AREAS AND OTHER SPECIFICATION AND INSTALLATION ISSUES. THESE APPLIANCES ARE NOT DESIGNED TO BE USED ON COOED SYSTEMS IN WHICH THE APPLIED VOLTAGE IS CYCLED ON AND OFF. FAILURE TO COMPLY WITH THE INSTALLATION INSTRUCTIONS OR GENERAL INFORMATION SHEETS COULD RESULT IN IMPROPER INSTALLATIC APPLICATION, AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. CONDUCTOR SIZE (AWG), LENGTH AND AMPACITY SHOULD BE TAKEN INTO CONSIDERATION PRIOR TO DESIGN AND INSTALLATION OF THESE PRODUCTS, PARTICULARLY IN RETROFIT INSTALLATIONS. Wiring Diagrams SERIES AS APPLIANCES NON-SYNCHRONIZED FROM TO NEXT PRECEDING APPLIANCE APPLIANCE OR EOLR OR FACP A NAC Circuit AS AS EOLR _1::::u:::::M~AudibIe NAC Circuit SERIES AS APPLIANCES SYNCHRONIZED W/ MULTIPLE DSM MODULES DSM #1 DSM Interconnecting wiring shown. Maximum of twenty (20) SERIES AS APPLIANCES SYNCHRONIZED W/ SM MODULE SINGLE CLASS "B" NAC CIRCUIT W/ AUDIBLESILENCE FEATURE SERIES AS & RSS APPLIANCES SYNCHRONIZED W/ PS-12-24-8 F '-4 4-CLASS A EOLR H Ou"PuTs OR C 2-CLASS S,i,, PS-12,24-e # For detail using SM or DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. For wiring information on the PS-1 2/24-8 Power Supply refer to Installation Instructions P83862. Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters' Laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). [] Arcnitects am! Ifl The notification appliances shall be Wheelock Series AS Audible Strobe appliances and Series AH Audible appliances or approved equals. The Series AS Audible be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The Series AH Audible shall be UL Listed under Standard 464 (Fire Protective Signaling). Both shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). The audible portion of the appliance shall have a minimum of three (3) field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3) audible outputs. The strobe portion of the appliance shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The Series AS shall be of low current design. Where Multi-Candela appliances are specified, the strobe intensity shall have a minimum of four (4) field selectable settings and shall be rated per UL Standard 1971 at: 15, 30, 75 and 110 candela for wall mount or 15, 30, 75, and 95 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant and not accessible from the front of the appliance. The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatible with Wheelock's SM, DSM Sync Modules or Wheelock's PS-1 2/24-8 Power Supply with built-in Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non- synchronized flash-rate. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation. The Series AS Audible Strobe and Series AH Audible shall incorporate a Patented Universal Mounting Plate that shall allow mounting to a single-gang, double-gang, 4-inch square, 100mm European type backboxes, or the SHBB Surface Backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided. All notification appliances shall be backward compatible. Specifications and Ordering Information Model Order Strobe candela Non5ync Sync wJSM, DSM or 24 12 Wall Ceiling MountIng Optlons Agency Approvals Code PS-12/24-8 VDC VD C Mount Mount UL MEA CSFM FM BFP AS-24MCW.fR 9024 15/30/75/110 X X X . X - A,B,D,E.F.H,J,N,O,R.X X X X X X AS-24MCW.FW 9025 15/30175/110 X X X - X - A.B4O.E,F,W-I.J.N,O.R.X X X X X X AS-241575W-FR 7405 15 (75 on Ads) X X X X - A,B,D,E,FAH.J,N,O,R.X X X X X X AS-121575W-FR 7410 15(75onAds) . X X . X X - A,8.D,E.F,I-I.JN,O,R.X X X X X X AS-24MCC-ffW 3162 15t30/75195 X X X . - X A,8.D,E.F,I-1,J,N,O.R.X . X * * * * AS1M-2475W-FR' 9012 75@-31 F X X X . X - l (see Data Sheet S9004) X X X X * AH-24-R 7892 - X X X -X X A.B,D,E,F.l-1,J,N,O.R)( X X X X X AH-12-R 7891 - X X - X X A,8.D.E,F,I-LJ,N,O,R.X X X x X AH-24.W.R 7416 - X X X X X K X X AH-12WP-R 7415 - X X - X X X K XX **For Weatherproof Series AS/AH specifications see data sheet S9004. *PENDING ***Refer to Data Sheet S7000 for Mounting Options. Note: Models are available in either Red or White. Contact Customer Service for Order Code and Delivery. NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc. standard terms and conditions. WE SUPPORT AND ENCOURAGE NICET CERTIFICATION NATIONAL SALES OFFICE 1-800-631-2148 Canada 800 397-5777 E-mail: Info@wheelockinc.com http://www.wheelockinc.com 3 YEAR WARRANTY Made in USA AMR Membr Distributed By: WHEELOCK, INC.. 273 BRANCHPORT AVE • LONG BRANCH, N.J. 07740 • 732-222-6880 • FAX: 732-222-2588 S810005/03