Loading...
HomeMy WebLinkAbout1811 ASTON AVE; 104; AS070130; PermitJob Address: 1811 ASTON AV Permit Type: SPRINK Parcel No: 2121201000 Lot #: 0 Status: ISSUED Applied 5/17/2007 Approved: 5/21/2007 Reference No.: Issued: 5/21/2007 City of Carlsbad Sprinkler Permit Permit No: AS070130 PC #: Inspector: Project Title: SPEC SUITE #104 TI FIRE SPRINKLER PLAN CHECK & INSPECTION Applicant: PARAMOUNT FIRE SYSTEMS, INC. P.O. BOX 713194 SANTEE, CA 619-562-6247 Owner: BLACKMORE FAMILY TRUST 1995 C/O ALLEN J BLACKMORE P0 BOX 424 RANCHO SANTA FE CA Fees ($) Add'I Fees ITotal ($) Balance ($) 124 0 124 0 Aso4t~a-, tqC0 Fire & Building IProducts Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Series TY-FRB —28,42,56, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright and Pendent Sprinklers described in this data sheet are quick response - standard cover- age, decorative 3 mm glass bulb type spray sprinklers designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels, shopping malls, etc. The recessed version of the Series TY-FRB Pendent Sprinkler, where ap- plicable, is intended for use in areas with a finished ceiling. It uses either a two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Es- cutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a two-piece Style 20(1/2 inch NPT) or Style 30(3/4 inch NPT) Recessed Escutcheon with 1/4.inch (6,4 mm) of recessed adjust- ment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pen- dent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- tained when exposed to corrosive at- IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 8 mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level versions of the Series TY-FRB Pendent Sprinklers are detailed in Technical Data Sheet TFP356, and Sprinkler Guards are de- tailed in Technical Data Sheet TFP780 WARNINGS The Series TY-FRB Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Numbers TY1131 - Upright 2.8K, 1/2NPT 1Y1231 - Pendent 2.8K, 1/2'NPT TY2131 - Upright 4.21K, 1/2"NPT 1Y2231 - Pendent 4.2K, 1/2"NPT 1Y3131 - Upright 5.6K, 112"NPT JULY, 2004 TY3231 - Pendent 5.6K, 1/2NPT TY4131 - Upright 8.0K, 3/4"NPT TY4231 - Pendent 8.01K, 3/4'NPT Technical Data Approvals UL and C-UL Listed. FM, LPCB, and NYC Approved. (Refer to Table A for complete approval information including corrosion resis- tant status.) Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K = 2.8 GPM/psi112 (40,3 LPM/barl'2) K = 4.2 GPM/psi112 (60,5 LPM/barl'2) K = 5.6 GPM/psi112 (80,6 LPM/barl'2) K = 8.0 GPM/psi1/2 (115,2 LPM/barll2) Temperature Ratings Refer to Table A and B TFPI7I ESCUTCHEON PLATE SEATING SURFACE 2-3/16" (55.6 mm) 1-1/2" (38,1 mm) 7/16" (11,1 mm) STYLE 10or2( 1/2' ** NOMINAL RECESSED I'.l DT MAKE-IN ESCUTCHEON SSP DEFLECTOR * 2-7/8" (73,0 mm) DIA. --1 Page 2 of 8 TFPI7I ESCUTCHEON PLATE SEATING SURFACE -r- \2-1/4' - (57,2 mm) 1-9/16" (39,7 mm) 7/16' (11,1 mm) STYLE 10 or 2( 1/2' ** NOMINAL RECESSED t,Ir MAKE-IN ESCUTCHEON DEFLECTOR 6 (11,1 mm) I 7/16" 1 _I5 NOMINAL I MAKE-IN (55,6mm) 2-3/16" H 1/2" NPT** SSP DEFLECTOR * 2-7/8" (73,0 mm) DIA. -I PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4- Bulb 6- Deflector * Temperature rating is indicated on deflector or adjaáent to 2 - Button Assembly 5 - Compression 7 - Bushing orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TYII3I) AND PENDENT (TY1231) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT SSU * DEFLECTOR 6* 7/16" I 5 (11,1 mm) AL NOMINAL MAKE-IN ; 2-3/16" (55,6 mm) 1/2" NPT** I PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3- Sealing 4- Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5- Compression orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K-FACTOR, 1/2 INCH NPT Finishes Bulb ..............Glass Sprinkler: Refer to Table A and B Compression Screw .....Bronze Recessed Escutcheon: White Coated, Deflector .......Copper/Bronze Chrome Plated, or Brass Plated Bushing (K=2.8) .......Bronze Physical Characteristics Frame .............Bronze Button .........Brass/Copper Sealing Assembly ............ Beryllium Nickel w/Teflonl- Operation The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. TFPI7I Page 3 of 8 ESCUTCHEON PLATE SEATING SURFACE 2-3/16' _ (55,6 mm) 1-1/2" (38,1 mm) 7/16 (11,1 mm) 1/2' ** NOMINAL KIDT MAKE-IN SSP DEFLECTOR* STYLE 100r20 RECESSED ESCUTCHEON SSU* 7/1 4 2-7/8 (73,0 mm) DIA. PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 56 K-FACTOR, 1/2 INCH NPT ESCUTCHEON 1/2(12,7mm) STYLE 30 or 40 PLATE SEATING ** NOMINAL RECESSED SURFACE NPT MAKE-IN ESCUTCHEON 2-5/16" (58,7 mm) 1-9/16" WRENCH FLATS 2-7/8 (73,0 mm) DIA. -J SSP DEFLECTOR* PENDENT RECESSED PENDENT SSU * DEFLECTOR 6* 1/2 5 (12,7 mm) I NOMINAL I MAKE-IN I 2-1/4" (57,2 mm) 3 3/4 NPT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4- Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2- Button Assembly 5 - Compression orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TV4131) AND PENDENT (TY4231) SPRINKLERS 8.0 K-FACTOR, 3/4 INCH NPT Design Criteria The Series TY-FRB Pendent and Up- right Sprinklers are intended for fire protection systems designed in ac- cordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Pre- vention Data Sheets ). Only the Style 10, 20, 30, or 40 Recessed Escutch- eon, as applicable, is to be used for recessed pendent installations. Installation The Series TY-FRB Sprinklers must be installed in accordance with the follow- ing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler Page 4 of 8 SPRINKLER FINISH (See Note 7) K TYPE TEMP. BULB NATURAL I CHROME I WHITE*** LIQUID BRASS PLATED IPOLYESTER 135°F/57°C Orange PENDENT (TY1231) and 12,3,5 155°F/68°C Red 175°F/79C Yellow UPRIGHT 2O0F/93°C Green 2.8 1/2" (TY1131) 286'F/1 41'C Blue NPT 135°F/57°C Orange RECESSED PENDENT 155°F/68°C Red 175°F/79°C Yellow (TV1231)* Figure 5 1,2, 5 200°F/93°C Green 135°F/57°C Orange RECESSED PENDENT 155°F/68°C Red 175°F/79°C Yellow (TY1231)** Figure 6 200°F/93°C Green 135°F/57°C Orange PENDENT (TY2231) 155°F/68C Red 175°F/79°0 Yellow and UPRIGHT 200°F/93C Green 4.2 1/2' (T'2131) 1,2 286'F/1 41'C Blue 135°F/57°C Orange NPT RECESSED PENDENT 155°F/68°C Red 175°F179°C Yellow (TY2231)* Figure 7 200°F/93°C Green 135F/57°C Orange RECESSED PENDENT 1 55°F/68°C Red 175°FT79C Yellow (TY2231)** Figure 8 200°F/93°C Green NOTES: Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprin- klers. 5. Approved by the City of New York under MEA 354-01-E. 7. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the Sprin- klers are UL and C-UL Listed as Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS 2.8 AND 4.2 K-FACTOR SPRINKLERS held horizontally, a small air bubble A leak tight 1/2 inch NPT sprinkler joint should be present. The diameter of the should be obtained with a torque of 7 air bubble is approximately 1/16 inch to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- (1,6 mm) for the 135°F/57°C to 3/32 mum of 21 ft. lbs. (28,5 Nm) of torque inch (2,4 mm) for the 286F/141°C may be used to install sprinklers with temperature ratings. 112 NPT connections. A leak tight 314 TFPI7I inch NPT sprinkler joint should be ob- tained with a torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). A maximum of 30 ft.lbs. (40,7 Nm) of torque is to be used to install sprinklers with 3/4 NPT con- nections. Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuffi- cient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. The Series TY-FRB Pendent and Up- right Sprinklers must be installed in accordance with the following instruc- tions. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 13). With reference to Figures 1, 2, 3, and 4, the W-Type 6 Sprinkler Wrench is to be applied to the sprinkler wrench flats. The Series TY-FRB Recessed Pen- dent Sprinklers must be installed in accordance with the following instruc- tions. Step A. After installing the Style 10. 20, 30, or 40 Mounting Plate, as appli- cable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprin- kler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 14). With reference to Figure 1, 2, 3, and 4, the W-Type 7 Recessed Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step C. After the ceiling has been in- stalled or the finish coat has been ap- plied, slide on the Style 10, 20, 30, or 40 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. TFPI7I Page 5 of 8 SPRINKLER FINISH (See Note 8) K TYPE TEMP. BULB NATURAL I CHROME I WHITE*** LEAD LIQUID BRASS I PLATED IPOLYESTER COATED 135°F/57°C Orange PENDENT (TY3231) and 1,2,3,45,6,7 1,2,3,5 155°F/68°C Red 175°F/79°C Yellow UPRIGHT 200°F/93°C Green 5.6 1/2° (TY3131) 286'F/1 41'C Blue NPT 135°F/57°C Orange RECESSED PENDENT (TY3231)* 1,2,4,5 N/A 155°F/68°C Red 175°F/79°C Yellow Figure 9 200°F/93°C Green 135°F/57°C Orange I RECESSED PENDENT (1Y3231)** 1,2,3,4,5 I I I 1,2,4,5 I N/A 155°F/68°C Red 175°F/79°C Yellow Figure 10 Green 200°F/93°C 135°F/57°C Orange PENDENT (TY4231) and 1,2, 3, 4, 5,6,7 1,2,5 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green UPRIGHT 8.0 3/4', (TY4131) 286°F/141°C Blue NPT 135°F/57°C Green RECESSED PENDENT (TY4231)* 1,2,4,5 N/A 155°F/68°C Orange 175°F/79°C Red Figure 11 200°F/93°C Yellow 135°F/57°C Orange RECESSED PENDENT (1Y4231)** 1, 2, 3,4,5 N/A 155°F/68°C Red 175°F/79°C Yellow Figure 12 200°F/93°C Green NOTES: Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers; however, the LPCB does not rate the thermal sensitivity of recessed sprinklers. Approved by the City of New York under MEA 354-01-E. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377). Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a106) as Quick Response Sprinklers. Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2 NPT) or Style 40 (3/4" NPT) 3/4' Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20 (1/2" NPT) or Style 30 (3/4° NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS 5.6 AND 8.0 K-FACTOR SPRINKLERS Page 6 of 8 - 2-7/8' DIA. 5/8±1/4" (73,0 mm) 3/4'(19,1 mm) 57,) (15,9±6,4 mm) 2-1/4" DIA. 1/4" (6,4 mm) FACE OF 2 mm MOUNTING I SPRINKLER PLATE FITTING I (3,12 mm) MOUNTING I SURFACE CLOSURE SERIES 1-5/16" (33,3 mm)f TY-FRB 13/16" (20,6 mm) FIGURE 5 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT - 2-7/8" DIA. 5/8±1/4" (73,0 mm) 3/4" (19,1 mm) (15,9±6,4 mm) 2-1/4" DIA. I 1/4" (6,4 mm) FACE OF ' MOUNTING 1/8' SPRINKLER PLATE I FITTING (3,2mm) MOUNTING SURFACE CLOSURE SERIES 1-1/4"(31,8 mm) TY-FRB 3/4'(19,1 mm) FIGURE 7 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT TFPI7I 2-7/8" DIA. (73,0 mm) 1/2±1/8" 1/2'(12,7 mm) r (12,7±3,2 mm) 2-1/4" DIA. 1/4(6,4mm) FACE OF qR (572 mm) MOUNTING SPRINKLE / FITTING PLATE (32 mm) MdUNTIN SURFACE I CLOSURE SERIES 1-5/16'(33,3 mm) TY-FRB 1-1/16'(27,0 mm) FIGURE 6 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT - 2-7/8" DIA. (73,0 mm) 1/2±1/8" I 1/2'(12,7mm) r (12,7±3,2 mm) - 2-1/4" DIA. I 1/4" (6,4 mm) FACE OF (57,2 mm) MOUNTING ) SPRINKLER PLATE FITTING (32mm) MOUNTING SURFACE SERIES 1-1/4'(31,8 mm) CLOSURE TY-FRB 1'(25,4 mm) FIGURE 8 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT Care and Maintenance The Series TY-FRB Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTES Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shutdown the affected fire protection system must be obtained from the proper authorities and all personnel who maybe affected by this action must be notified. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic Sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been com- pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- TFPI7I - 2-7/8" DIA. 5/8±1/4" (73,0 mm) I 3/4" (19,1 mm) (159±6,4 mm) __. 2-1/4' DIA. 1/4" (6,4 mm) FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE FITTING (32 m_j 1/8" '7 MOUNTING I SURFACE SERIES 1-1/4"(31,8 mm)1 CLOSURE TYFRB 3/4'(19,1 mm) FIGURE 9 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT - 2-7/8' DIA. 5/8±1/4" (73,0 mm) 314"(19,1 mm) - (15,9±6,4mm) 2-1/4" DIA. 1/4'(6,4 mm) FACE OF4 R 1 (57,2 mm) MOUNTING I 1/8" SPRINKLE PLATE FITtING (3,2 mm) MOUNTIN SURFACE CLOSURE SERIES 1-5/16" (33,3 mm)f TY-FRB 13/16"(20,6 mm) FIGURE 11 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT Page 7 of 8 - 2-7/8" DIA. (73,0 mm) 1/2±1/8" I 1/2"(12,7mm) r (12,7±3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm) FACE OF (57,2 mm) MOUNTING I PLATE I SPRINKLER 1/8" / ______ I FITTING I \ I t MOUNTING SURFACE SERIES 1-1/4" (31,8 mm) CLOSURE TYFRB 1'(25,4 mm) FIGURE 10 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT - 2-7/8" DIA. 1/2*1/8" (73,0 mm) 1/2"(12,7 mm) E (12,7±3,2 mm) - 2-1/4" DIA. 1/4" (6,4 mm) FACE OF (57,2 mm) MOUNTING I 2# ' SPRINKLER PLATE I FITTING (3,12 mm) \ MOUNTING SURFACE/ CLOSURE SERIES 1-5/16'(33,3 mm) TV-FRB 1-1/16"(27,0 mm) FIGURE 12 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection System and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with WRENCH RECESS (END "A" USED FOR 1/2' NPT MODELS) WRENCH RECESS (END UB USED FOR 3/4" NPT MODELS) FIGURE 13 W-TYPE 6 SPRINKLER WRENCH local requirements and/or national codes. WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 14 W-TYPE 7 RECESSED SPRINKLER WRENCH p Page 8 of 8 TFPI7I P/N 57 - XXX - X - XXX I L MODEL/SIN 330 2.8K UPRIGHT (1/2NPT) TY1131 331 2.8K PENDENT (1/2'NPT) TY1231 340 4.2K UPRIGHT (1/2'NPT) TY2131 341 4.2K PENDENT (1/2NPT) TY2231 370 5.6K UPRIGHT (1/2NPT) TY3131 371 5.6K PENDENT (1/2'NPT) TY3231 390 8.0K UPRIGHT (3/4NPT) TY4131 391 8.0K PENDENT (3/4NPT) TY4231 I I L 135 SPRINKLER I 155 175 200 286 RATING 1 NATURAL BRASS 155°F168°C 4 WHITE POLYESTER 175*F/79*C 3 WHITE (RAL9O1O)* 200' WC 9 CHROME PLATED 286°F/141°C 7 LEAD COATED * Eastern Hemisphere sales only. TABLE C PART NUMBER SELECTION SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by Tyco Fire Products. No war- ranty is given for products or components manufactured by compa- nies not affiliated by ownership with TycO Fire Products or for products and components which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in ac- cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither as- sumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE- GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS .1ILYti;i;Td!I1I1*f.1J Ordering Procedure ®lttur tecal distributor for avail- abftly.indiCate the full product name. Refer to the Price List for complete listing of Part Numbers. Sprinkler Assemblies with NPT Thread Connections: Specify: (Specify Model/SIN), Quick Response, (specify K-factor), (specify temperature rating), Series TY-FRB (specify Pendent or Upright) Sprinkler with (specify type of finish or coating), P/N (specify from Table C). Recessed Escutcheon: Specify: Style (specify) Recessed Es- cutcheon with (specify finish), P/N (specify). 1/2 (15 mm) Style 10 Chrome Plated ............P/N 56-701-9-010 White Coated .............P/N 56-701-4-010 White RAL9O1O. ........... P/N 56-701-3-010 Brass Plated ..............P/N 56-701-2-010 1/2 (15 mm) Style 20 Chrome Plated ............P/N 56-705-9-010 White Coated .............P/N 56-705-4-010 White RAL9010*P/N 56-705-3-010 Brass Plated ..............P/N 56-705-2-010 3/4 (20 mm) Style 30 Chrome Plated ............P/N 56-705-9-011 White Coated .............P/N 56-705-4-011 White RAL9010*P/N 56-705-3-011 Brass Plated ..............P/N 56-705-2-011 3/4* (20 mm) Style 40 Chrome Plated ............P/N 56-700-9-010 White Coated .............P/N 56-700-4-010 White RAL9010*P/N 56-700-3-010 Brass Plated ..............P/N 56-700-2-010 * Eastern Hemisphere sales Only. Sprinkler Wrench: Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446