Loading...
HomeMy WebLinkAbout1817 ASTON AVE; 104; AS070170; PermitCity of Carlsbad Sprinkler Permit Permit No: AS070170 Job Address: 1817 ASTON AV 4 to4 Status: ISSUED Permit Type: SPRINK Applied 6/21/2007 Parcel No: Approved: 7/12/2007 Lot #: 0 Reference No.: Issued: 7/12/2007 PC #: Inspector: Project Title NRG SUITE TI FIRE SPRINKLER PLAN CHECK & INSPECTION Applicant: WEST COAST FIRE PROTECTION 271 ROYMAR RD SUITE F OCEANSIDE, CA (760)754-8472 Owner: Fees ($) Add'I Fees(s) Total ($) Balance ($) 124 0 1,24 0 many angles, reducing assembly effort. This sprin- kler is available in various temperature ratings (see chart on page 2) and fin- ishes to meet many design requirements. The recessed pendent should be utilized with a Model V27 recessed escutcheon which pro- vides up to 3/4" (19 mm) of adjustments. Sprinkler Operation The operating mechanism is a frangible glass bulb which contains a heat responsive liquid. During a fire, the ambient tempera- ture rises causing the liquid in the bulb to expand. When the ambient temper- ature reaches the rated temperature of the sprin- kler, the bulb shatters. As a result, the waterway is cleared of all sealing parts and water is discharged towards the deflector. The deflector is designed to dis- tribute the water in a pat- tern that is most effective in controlling the fire. Coverage For coverage area and sprinkler placement, refer to NFPA 13 standards. J1"tauIac® FIRE PROTECTION, P% 40.10 V27, K5.6 Models V2703, V2704, V2707 and V2708 Standard Spray Upright, Pendent and Recessed Pendent Standard and Quick Response PRODUCT DESCRIPTION These Model V27 standard spray sprinklers are designed to produce a hemispherical spray pat- 4V2708 tern for standard commer- cial applications. They are available with either stan- Recessed dard or quick response Pendent bulbs. The design incorpo- () () rates state-of-the-art, heat <FM > responsive, frangible glass J See Victaulic bulb design (standard or publication 1001 for details. quick response) for prompt, V2707 V2708 precise operation. The die cast frame is more streamlined and attractive than traditional sand cast Pendent frames. It is cast with a V2703 hex-shaped wrench boss to V2704 allow easy tightening from Upright TECHNICAL SPECIFICATIONS Models: V2703, V2704, V2707 V2708 Style: Pendent, Upright or Recessed Pendent Nominal Orifice Size: ½" (13 mm) K-Factor: 5.6 Imp. (8.1 S.I.) Nominal Thread Size: ½" NPT (15 111111) Max. Working Pressure: 175 psi (1200 kPa) Factory Hydrostatic Test: 100% @ 500 psi (34 50 kPa) Mm. Operating Pressure: 7 psi (48 kPa) Temperature Rating: See chart on page 2. MATERIAL SPECIFICATIONS Upright Deflector: Bronze per UNS C22000 Pendent Deflector: Bronze per UNS C51000 Bulb: Glass with glycerin solu- tion. Bulb Nominal Diameter: U Standard: 5,0 mm U Quick Response: 3,0 mm Load Screw: Bronze per UNS C65100 Pip Cap: Bronze per UNS 065100 Spring: Beryllium nickel Seal: lellon* tape Frame: Die cast brass 65-30 Lodgement Spring: Stainless steel per UNS S30200 ACCESSORIES Installation Wrench: U Open End: V27 U Recessed: V38, V38-3 U Socket: V27 Finishes: U Plain brass U Chrome plated U White paintedu* U Custom painted** U Lead 155, 200, 286SR Only: U Wax" U Wax over lead** For cabinets and other accesso- ries icier to separate sheet. NOTE: Weather resistant recessed escutcheons available upon request. For K-Factor when pressure is mea- sured in Bar, multiply S.I. units by 10.0. Tellort is a registered trademark of Dupont Co. UL Listed for corrosion resistance in all configurations, VICTAULIC® IS AN ISO 9001 CERTIFIED COMPANY Victaulic Company of America Victaulic Company of Canada Victaulic Europe Victaulic America Latina Victaulic Asia Pacific Phone: 1.800.PICK-VIC (1-800.742-5842) Phone: 905-884-7444 Phone: 32-9-381.1500 Phone: 610-559-3300 Phone: 65-6235-3035 Fix: 610-250-8817 Fan: 905.881.9774 Fax: 32.9-380-1438 Fax: 610-559-3608 Fax: 65-6235-0535 e.rnail:pickvichPvictaxlic.conl e-mail: viccaxada@victaalic.com e-mail: viceuro@viclaulic.be e-mail: vical@victaulic.com e-mail: vicap@yvicIaulic.com 2544 Rev.D 803 5 Registered Trademark of ctauIic 0 Copyright 2003 Vesaulic Printed in U.S.A. APPROVALS/LISTINGS Nominal Approved Temperature Ratings °FPC t £2 Orifice Size K-Factor Inches Imperial Deflector Model millimeters S.I. Response Type UL FM ULC NYC/MEAt CSFM § ½5.6 135-360 135-360 135-360 135-360 135-360 V2703 13 8,1 Standard Upright 57-182 57-182 57-182 57-182 57-182 ½ 5.6 135-360 135-360 135-360 135-360 135-360 V2707 13 8.1 Standard Pendent 57-182 57-182 57-182 57-182 57-182 ½ 5.6 Recessed Pendent 135-360 135-200 135-360 135-360 135-360 V2707 13 8.1 Standard Up to 9/4" Adjustment 57-182 57-93 57-182 57-182 57-182 ½ 5.6 135-286 135-286 135-286 135-286 135-286 V2704 13 8,1 Quick Upright 57-141 57-141 1 57-141 57-141 57 - 141 ½ 5.6 135-286 135-286 135-286 135-286 V2708 13 8,1 Quick Pendent 57-141 57-141 135 - 286 57-141 57-141 57-141 1h 5.6 Recessed Pendent 135-200 135-200 135-200 135-200 135-200 V2708 13 8.1 Quick Up to I& Adjustment 57-93 57-93 57-93 57-93 57-93 ½ 5.6 Recessed Pendent 135-200 135-200 135-200 135-200 V2708 13 8,1 Quick Up to 3/4' Adjustment 5793 No 5793 5793 -1 Listings and approval as or printing. 55 Alt are approvea open, except ior areas aesignatea i,4o ' For K-Factor when pressure is measured in Bar, multiply S.I. units by 10. I MEAif62-99-E. § CSFM #7690-0531:112 ( RATINGS All glass bulbs are rated for temperatures from -67°F (-55°C) up to those shown in adjacent table. Temperature - °F/°C Sprinkler Victaulic Nominal Maximum Glass Temperature Part Temperature Ambient Temp. Bulb Classification Identification Rating Allowed Color Ordinary A 135 57 100 38 Orange Ordinary C 155 100 68 38 Red Intermediate E 175 150 79 65 Yellow Intermediate F 200 150 g 65 Green High - 286 141 225 - 107 Blue Extra High K 360 182 300 149 Purple - M Open : No Bulb 1 Standard response only. All are approved open, except for areas designated "No". - 150/65 if wax coated. ORDERING INFORMATION Please specify the following when ordering: U Sprinkler Model Number 0 K-Factor U Sprinkler Finish U Style U Thread Size U Escutcheon Finish U Temperature Rating U Quantity Wrench Model Number Always read and understand installation, care, and maintenance instructions, supplied with each box of sprinklers, before proceeding with installation of any sprinklers. - Always wear safety glasses and foot protection. - Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. . 0 - Installation rules, especially those governing obstruction, must be strictly followed. Painting, plating, or any re-coating of sprinklers (other than that supplied by Victaulic) is not allowed. Failua-e to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pamphlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters, P.O. Box 31, Easton, Pennsylvania 18044-0031, 610-559-3300. 40.10-2 ( -t DIMENSIONS 2W (60 MM) ~ 1 I (41 mm) (25 mm) Standard Pendent - V2707, V2708 (60 Standard Upright. V2703, V2704 mm) Max. Hole T(51 mm) F 23N'(60 Mm. Hole (17 ) (14 mm) Typical Ceiling Tile t I Finished Surface (30 mm) (43 mm) MAXIMUM RECESS 211A."_________ (75 mm> MAXIMUM EXTENSION ½" Adjustment Recessed . V2707, V2708 (Drawing not to scale) (60 mm) Max. Hole in Hole Typical Ceiling Tile (2:) :i:,, 'J>' Finished 'Surface J mm) (43 MITI) 2lo' (75 mm) MAXIMUM EXTENSION Y4 Adjustment Recessed V2707, V2708 (Drawing not to scale) AVAILABLE WRENCHES V27 Socket V38 or V38.3 Recessed V27 Open End V2707, V2708 Pendent / / / V2707, V2708 Recessed Pendent / / - V2703. V2704 Upright 40.10-3 - m ---- - -- -- to - - __s --- m - \ - N m 11111 '1 ~ I ±hd 10' 3,0 m 811, 2,4 6 1,8 4 1,2 2 0,6 0 7 psi 48 kPa 15 psi 103 kPa 30 psi ------ 207 kPa I __J DISTRIBUTION PATTERNS MODELS V2707, V2708 K5.6 STANDARD PENDENT AND RECESSED PENDENT DISTRIBUTION PATTERNS - TRAJECTORY 10' 3,0 no 8' 2,4 m 6' 1,8 m 4, 1,2 m 2' 0,6 m 0 7 psi 48 kPa 15 psi 103 kPa 30 psi ------- 207 kPa 2' 4' 6' 8' 10' 12' 14' 0,6 m 1,2w 1,8 m 2,4 m 3,0 m 3,7 m 4,3 m MODELS V2103, V2704 K5.6 STANDARD UPRIGHT DISTRIBUTION PATTERNS - TRAJECTORY 0,6m 1,2m 1,8m 2,4m 3,0m 3,7m 4,3m 4,9m NOTES: Data shown is approximate and can vary due to differences in installation. These graphs illustrate approximate trajectories, floor-wetting. and wall-wetting patterns for these specific Victaulic FireLock Automatic Sprinklers. They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation. Refer to the appropriate NFPA National Fire Code and the authority having jurisdiction for specific information regarding obstructions. spacing limitations and area of coverage rc-'quiremetits. Failure to follow these guldelities could adversely affect the performance of the sprinkler and will void all Listings. Approvals and War- rant ie.s. All patterns are symmetrical to the centerline of the waterway. 1 WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. This product shall be manufactured by Victaulic Company. AR products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. 40.10-4