Project Title: PACKARD DENTAL OFFICE
Applicant:
INNOVATIVE FIRE PROTECTION INC
STE 101
8779 COTTONWOOD AV
SANTEE CA
(619) 593-8200 (619)593-9133
Owner:
CARLSBAD MEDICAL VILLAGE L P
C/O RUSS RIES
P 0 BOX 1422
LA JOLLA CA
Fees ($) Add'I Fees ($) 1Total ($)Balance
280 0 280 0
1/1
Bulletin 014 Rev. M
liable Model Fl FR Series
Quick Response
Glass Bulb Sprinklers
C
CD
CD
SO
Model Fl FR56 Sprinkler Types
Standard Spray Upright
Standard Spray Pendent
Conventional Upright/Pendent
Vertical Sidewall
Horizontal Sidewall
Model Fl FR56 Recessed Sprinkler Types
Standard Spray Pendent
Horizontal Sidewall
Model F1 FR56 Concealed Sprinkler Types
Standard Spray Pendent
Model Fl FR42, Fl FRXLH & Fl FR28 Sprinkler
Types -.
Standard Spray Upriht
Standard Spray Pendent
Model F1FR40 Sprinkler Types
Standard Spray Pendent
Model F1FR42, F1FR40, F1FRXLH & F1FR28
Recessed Sprinkler Types
Standard Spray Pendent
Model Fl FR56LL & Fl FR42LL NSF Certified Low
Lead Sprinkler Types
Standard Spray Pendent with less than 0.25% Lead
Content
Upright Pendent Conventional
1RiT1
L LJL!1_J Vt tiLcil Sidewall - Bor'zontal Sidbwall - . Recessed
- PendentlFl/F2
Recessed Concealed Recessed
Horizontal Sidewall Pendent PendentjFP
XLH Upright XLH Pendent XLH Recessed
Pendent F1/F2
1, Underwriters Laboratories Inc. and Certified for
Canada (cULus).
FM Approvals (FM)
Loss Prevention Certification Board (LPCB)
Vertrauen durch Sicherheit (VdS)
NSF Certified to NSF/ANSi Standard 61 Annex G
(NSF)
EC Certificate: 0786-CPD-40239 (RA1414), 0786-
CPD-4025 1 (RA1425), 0786-CPD-40252 (RA1 475)
(EC)
UL Listing Category
Sprinklers, Automatic & Open (VNIV)
Quick Response Sprinkler
kler.
Product Description
AS150219
Reliable Automatic Sprinkler Co., Inc., 103
Listing & Approvals
The following organizations provide Listings or Approvals
for various Model F1FR series sprinklers. See the Design
and Installation table in this Bulletin for information on
specific listings and approvals applicable to each sprin-
Reliable Model F1FR series sprinklers .
are quick-response automatic sprin-
klers with a glass bulb thermal element
- Model F1FR series sprinklers are Stan- -,
dard Spray sprinklers, with the excep-
tion of the Model F1FR56 Conventional XLH Recessed
sprinkler which is an Old-style/Conven- Pendent FR
tional sprinkler.
The Model F1FR Series automatic sprinklers utilize a 3.0
mm frangible glass bulb. These sprinklers have demonstrat-
ed response times in laboratory tests which are five to ten
times faster than standard response sprinklers. This quick
response enables the Model Fl FR Series sprinklers to apply
water to a fire faster than standard-response sprinklers of the
same temperature rating.
The glass bulb consists of an accurately controlled amount
of special fluid hermetically sealed inside a precisely man-
ufactured glass capsule. This glass bulb is specially con-
structed to provide fast thermal response.
Fairview. Park Drive, Elmsford, New York 10523
At normal temperatures, the glass bulb contains the fluid Model F1FR Series sprinklers must be installed with the
in both the liquid and vapor phases. The vapor phase can Reliable sprinkler installation wrench identified in the Design
be seen as a small bubble. As heat is applied, the liquid and Installation Information table in this Bulletin. Any other
expands, forcing the bubble smaller and smaller as the liq- wrench may damage the sprinkler. A leak tight sprinkler joint
Uid pressure increases. Continued heating forces the liquid can be obtained with a torque of 8 to 18 lb-ft (11 to 24 N-M).
to push out against the bulb, causing the glass to shatter, Do not tighten sprinklers over the maximum recommended
opening the waterway and allowing the deflector to distrib- installation torque. Exceeding the maximum recommended
ute the discharging water. installation torque may cause leakage or impairment of the
Model Fl FR Series sprinklers provide a wide range of op- sprinkler.
tions where* quick-response, glass bulb sprinklers are used: Recessed Sprinklers
Pendent, recessed pendent, upright, horizontal side- Model F1FR Series Recessed sprinklers are to be installed
wall, and vertical sidewall deflectors as shown in Fig. 1, Fig. 2, or Fig. 3, as applicable to the spe-
K-factors of 2.8 (40 metric), 4.0 (57 metric), 4.2 (60 cific model being installed. The Recessed Escutcheon Data
metric), and 5.6 (80 metric) table in the Bulletin identifies the only recessed escutcheons
Flush, recessed, and concealed installations that are permitted to be used with each Model F1FR Series
See the Design and Installation Information table in this Recessed sprinkler. The use of any other recessed escutch-
Bulletin for information on the approvals and availability of eon will void all approvals and negate all warranties.
specific Model F1FR series sprinkler configurations. Concealed Sprinklers
Model F1FR Recessed Pendent and Recessed Horizon- Model F1FR Series Concealed Pendent sprinklers are to
tal Sidewall sprinklers are required to be used with Reliable be installed as shown in Fig. 4 or Fig. 5, as applicable to the
Model Fl, F2 or FP recessed escutcheons. See the Re- selected cover plate. Model F1FR56 Concealed Pendant
cessed Escutcheon Data table in this Bulletin for listing and and Model Fl FR56LL Concealed Pendent sprinklers have
aooro9l1nformbenithreachspecbc.Modei FTFR series .T a .ffor tltqdMd'djcPoA;..d.rpteptLve C is, in:
Model Fl and F2'iCce5Cd dcutci ieons, shown it i stalled at the factory that SFdd remain on the 'sprinkler until
Fig. 1 and 3, are a friction fit assembly allowing for 3/4-inch the sprinkler is installed and should then be reinstalled on
I (19mm) and 1/2-inch (12.7mm) of adjustment, respectively, the sprinkler until the cover plate is installed. The concealed
Model FP recessed escutcheons, shown in Fig. 2, provide a sprinkler assemblies are completed by the installation of a
1/2-inch (12. 7mm) threaded adjustment. Model CCP push-on/thread-off cover plate assembly. The
Model F1FR56 Concealed Pendent and Model F1FR56LL cover plate and sprinkler cup assemblies are joined using
Concealed Pendent sprinklers are required to be used with a cover plate skirt with flexible tabs for threaded engage-
Model CCP cover plates. A standard profile Model CCP coy- ment. A choice of two Model CCP cover plate assemblies
er plate is available that provides up to 1/2-inch (12.7mm) of provides either 1/2-inch (13mm) or 5/8-inch (8mm) of cover
cover plate adjustment. In addition, a low profile Model CCP adjustment. Do not install Model F1FR Series Concealed
cover plate is also available that provides up to 5/16-inch Pendent sprinklers in ceilings which have positive pressure
(8.0mm) of cover plate adjustment. See the Design and In- in the space above.
stallation Information and Listed and Approved Temperature Model F1FR Series Concealed Pendent sprinklers require a
Ratings tables in this Bulletin for further information on ap- 2-5/8-inch (67mm) diameter hole to be cut in the ceiling. The
proved cover plate options. Model AOl wrench is used to engage the sprinkler wrenching
Application surfaces and to install the sprinkler in the fitting. Remove the
Model Fl FR Series sprinklers are intended for use in protective cap to install the sprinkler, then reinstall the protective
accordance with NFPA 13, FM Property Loss Prevention cap until the cover plate is installed. When inserting or remov-
Data Sheets, and the requirements of the Authority Hay- ing the wrench from the sprinkler/cup assembly, care should be
ing Jurisdiction. Care must be exercised that the k-factor, taken to prevent damage to the sprinkler. Do not wrench any
temperature rating, deflector style, and sprinkler type are other part of the sprinkler/cup assembly. Installation is com-
in accordance with the requirements of the applicable plated by removing the protective cap from the sprinkler and
design and installation standards. In addition, Model pushing the cover plate onto the cup. Final adjustment is made
Fl FR Series sprinklers must be used in accordance with by hand turning the cover plate until the skirl flange makes full
their listings and approvals, as well as the information contact with the ceiling. Cover plate removal requires turning the
provided in this Bulletin, cover plate in the counter clockwise direction. After installation,
Installation inspect all sprinklers to ensure that there is a gap between the
Glass bulb sprinklers have orange bulb protectors or pro- cover plate and ceiling and that the four cup slots are open and
tective caps to minimize bulb damage during shipping, han- free from any air flow impediment to the space above.
dling and installation. Reliable sprinkler installation wrench- Concealed cover plate/cup assemblies are listed only for
es are designed to install sprinklers with bulb protectors in use with specific sprinklers. The use of any concealed cover
place. Remove the bulb protector at the time when the sprin- plate/cup assembly other than the Reliable Model CCP with
kler system is placed in service for fire protection. Removal Model F1FR56 Concealed Pendent and Model F1FR56LL
of the bulb protector before this time may leave the bulb vul- Concealed Pendant sprinklers or the use of the Model CCP
nerable to damage. Remove bulb protectors by undoing the Concealed cover plate assembly on any sprinkler with which
clasp by hand. Do not use tools to remove bulb protectors. it is not specifically listed my prevent good fire protection and
will void all guarantees, warranties, listings and approvals.
2.
Technical Data:
Sensitivity: Quick-response
Thread Size: 1/2-inch NPT standard; ISO 7-RI/2 optional
Maximum Working Pressure: 175 psi (12 bar) - 100% Factory tested hydrostatically to 500 psi (34.5 bar)
Design and Installation Information
Nominal Nominal Listings
Mod Orifice Deflector! Sprinkler Installation SIN and Approval
Diameter Orientation Height Wrench Notes I Approvals inches mm inches mm
I Pendent 225 57 0 RA1411 cULus 2
F1FR2 3/8 10 Recessed Pendent 225 57 GFR2 RA1411 cULus 2
A26
Upright 225 57 0 RA1421 cULus 1,2
I Pendent 225 57 0 RA1418 VdS F1FR4 3/8 I 10
Recessed Pendent 225 57 GFR2 RA1418 VdS
Pendent 225 57 D RA1413 cULus 2
F1FR4 7/16 10 Recessed Pendent 225 1 57 GFR2 RA1413 cULus 2
Upright 225 1 57 D RA1423 cULus 1,2
I Pendent 225 57 0 RA1410 cULus, NSF F1FR42LL 42 10 60 7/16 I
.Heessed_Pendeot 225-+--_5,.-7-.-,FR2 RA141O -cUbos;NSF'.
:-FFLkLh .
' Fndeit 25 57 -HGJL&
(Fl FR42 4 2 60 7/16 10 Recessed Pendent 2 25 57 GFR2 RA1413 cULus 2
with Pintle) Upright 225 57 D RA1423 cULus 1,2
Pendent 225 57 D
1 LPC8,VdS,EC RA1414 cULus, FM. i__J
Recessed Pendent 225 57 GFR2 RA1414 LPCB,VdS,EC 1,2,34
F1FR56 5.6 80 1/2 15 concealed Pendent 225 57 1 RC1 i RA1414 cULus, VdS. EC 5,6
Upright 225 57 D RA1425 cULus FM
LPCB,VdS,EC 1,2,3,4
Conventional
,, (Pendent or Upnght) 225 57 D HA 1475 LPCB, VdS, EC
I
4
Pendent 225 57 D RA1415 cULus, NSF 1
F1FR56LL 5,6 80 1/2 15 Recessed Pendent 225 1 57 GFR2 RA1415 cULus, NSF
Concealed Pendent 225 1 57 RC1 RA1414 cULus, NSF 6
Horizontal Sidewall 263 1 67 D RA1435 cULus, FM 123,7
F1FR56 56 80 1/2 15 Recessed Horizontal
Sidewall 263 67 GFR2 RA1435 cULus, FM 8
F1FR56 5.6 80 /2 15 Vertical Sidewall 225 57 D RA1485 cULus FM 1,23,9 (Pendent orUpright) LPCB
cULus Listed corrosion Resistant sprinkler when ordered with available Polyester coating.
CULLIS Listed Corrosion Resistant sprinkler when ordered with available Electroless Nickel PTFE plating.
Available with FM approved Polyester coating in black or white,
'fl Available with LPCB and VdS approved Polyester coating.
VdS and EC approvals 01 the F1FRS6 Concealed Pendent sprinkler are for 155°F (68°C) temperature rated sprinklers only. VdS approved sprin-
klers must use Norbulb brand glass bulbs with the 1/2-inch (12. 7mm) adjustment Model CCP cover plate only.
Model F1FR56 Concealed Pendent and Model F1FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates,
available as either standard depth with 1/2-inch (12.7mm) of adjustment or low profile with 5/16-inch (8.0 mm) of adjustment.
cULus Listing of the F1FR56 Horizontal Sidewall sprinkler is for Light and Ordinary Hazard occupancies only. FM Approval of the FlFR56 Hori-
zontal Sidewall sprinkler is for Light Hazard occupancies only.
cULus Listing and FM Approval of the F1FR56 Recessed Horizontal Sidewall sprinkler is for Light Hazard occupancies only.
The F1FR56 Vertical Sidewall sprinkler is listed and approved for use only in Light Hazard occupancies. Minimum to maximum deflector to ceil-
ing distance shall be 4 inches to 12 inches (102mm to 305mm). LPCB approval of the F1FR56 Vertical Sidewall sprinkler is for installation in the
Pendant position only.
3.
Listed and Approved Temperature Ratings
Ordinary Temp. Intermediate Temp. High Temp.
Classification Classification Classification
100°F (38°C) Max. Ambient 150°F (65°C) Max. Ambient 225°F (107°C) Max. Deflector! Model Temp. Temp. I Ambient Orientation 135°F (57°C) 155°F (68°C) 175°F (79°C) I 200°F(93°C) 286°F (141°C) Temp. I
Temp. Rating Temp. Rating Temp. Rating Temp. Rating Rating
Orange Bulb Red Bulb Yellow Bulb Green Bulb Blue Bulb
Pendent cULus
F1 FR28 Recessed Pendent cULus
Upright cULus
Pendent VdS F1 FR40
Recessed Pendent VdS
Pendant cULus
F1FR42 Recessed Pendent cULus
L I Upright cULus
IF1FR42LL/ Pendent -- cULus, NSF --
Recessed Pendent cULus, NSF -
Pendent cULus
F1FRXLH Recessed Pendent cULus --
- ,HAndent
Recessed Pendent
-
- - JLs FM, L'C8
cULus, FM, LPCB, VdS, EC
F1FR56 Concealed Pendent cULus cULus,VdS,EC cULus
Upright CULUS, FM, LPCB, VdS, EC
Conventional
(Pendant or Upright)" LPCB VhS EC
Pendant -- cULus, NSF --
F1FR56LL Recessed Pendent -- cULus, NSF --
Concealed Pendent" -- cULus, NSF --
Horizontal Sidewall cULus, FM
F1FR56 Recessed Horizontal
Sidewall I
cULus, FM T --
F1FR56 Vertical Sidewall (Pen-
dent or Upright) cULus, FM, LPCB
* Model F1FR56 Concealed Pendent and F1FR56LL Concealed Pendent sprinklers must be used with Reliable Model
CCP cover plates. For Ordinary Temperature Classification sprinklers use a 135°F (57°C) temperature rated cover
plate. For Intermediate Temperature Classification sprinklers use a 165°F (74°C) temperature rated cover plate.
Recessed Escutcheon Data
Listed and Approved Recessed Escutcheons
Model Fl Model F2 Model FP
Model Deflector! (Fig. 1 & 3) (Fig. 1 & 3) (Fig. 2) SIN Orientation 3/4-inch (19mm) 1/2-inch (12.7mm) 1/2-inch (12.7mm)
adjustment adjustment adjustment
F1FR28 Recessed Pendant cULus cULus cULus RA1411
F1FR40 Recessed Pendent VdS VdS VdS RA1418
F1FR42 Recessed Pendent cULus cULus cULus RA1413
F1FR42LL Recessed Pendant cULus, NSF cULus, NSF cULus, NSF RA1410
F1FR42XLH Recessed Pendent cULus cULus cULus RA1413
F1FR56 Recessed Pendant cULus, LPCB, VdS, cULus, FM, LPCB, cULus, VdS, EC R,A1414 EC VdS, EC
F1FR56LL Recessed Pendant cULus, NSF cULus, NSF cULus, NSF RA1415
F1FR56 Recessed Horizontal Sidewall cULus cULus, FM cULus RA1435
c
I -,A
2 5/8" 0/A. [66.7mm]
HOLE IN CEILING
2 5/16" 0/A. [58.7mm] -- -- -
CUP
CEILING FACE OF FITTING
TO FACE OF CEILING
DIMENSION
AT MAXIMUM RECESS = 1-1/2738mm]
AT MINIMUM RECESS = 1 '[25.4mm]
2 1/4 HOLE 0/A.
f57.2]
LLEUHEON_
ADJUSTMENT
F2 ESCUTCHEON
1/2[12.7mm]
ADJUSTMENT
2 27/32 0/A.
[72.2r]
I" X 1/2" REOUCER
FACE OF FITTING
TO FACE OF CEILING DIMENSION
Fl ESCUTCHEON
AT MAXIMUM RECESS I 725.4mm]
AT MINIMUM RECESS = 3/8 79.5mm]
/ F2 ESCUTCHEON
AT MAXIMUM RECESS = 3/4719mm]
AT MINIMUM RECESS = 3/8(9.5mm]
Fl ESCUTCHEON
AT MAXIMUM RECESS = 7/8722.2mm]
fJ.2j I / AT MINIMUM RECESS = 1-5/8741.3mm]
r F2 ESCUTCHEON
- AT MAXIMUM RECESS = 1- 1/8 728.6mm]
./IT.MINIMUM.RSCCSS.,,i-5/8741.3mm]
TURN COLLAR
UNTIL TIGHT
AGAINST SPRINKLER
WRENCH BOSS
Fig. 1
Mode! F1FR56, F1FR56LL, F1FR42, F1FR40, F1FR42LL, F1FRXLH & F1FR28
Recessed Pendent sprinkler with Mode! Fl or F2 escutcheon
IX 1/2" REDUCER
J AT MAX/MUM RECESS = 9/167i3mm]
AT WINIMUM RECESS 1'[25.4m-]
3 1/4" 0/A.
[82.6mm]
Fig. 2
Mode! F1FR56, F1FR56LL, F1FR42, F1FR40, F1FR421-L, F1FRXLH & F1FR28
Recessed Pendent sprinkler with Model FP escutcheon
5.
2 5/16" 0/A -
CUP
CEILING
1 ESCUTCHEON
MAX/MUM RECESS = 1-3/8"[34.9mm]
AT MINIMUM RECESS = 2-1116'T52 .4mml
F2 ESCUTCHEON
AT MAX/MUM RECESS = 1-5/8"[41.3mm]
AT MINIMUM RECESS = 2-1/16 '[52.4mm]
FACE OF FITTING ro FACE OF CEILING DIMENSION
Fl ESCUTCHEON
AT MAX/MUM RECESS = 1 '[25.4mm]
AT MINIMUM RECESS = 3/8 "[9.5mm]
F2 ESCUTCHEON
AT MAX/MUM RECESS = 3/4"[19mm]
AT MINIMUM RECESS = 3/8 '[9.5mm]
2 1/4" HOLE 0/A.
[5 7.2mm]
1" X 1/2" REDUCER
2 27/32" 0/A.
[72.2mm]
TURN COLLAR UNTIL -
TIGHT AGAINST SPRINKLER
WRENCH 80-5.5 .ELESCUTCUN .. ....
F2 ESCUTCHEON
1/2"[12.7mm] ADJUSTMENT
RECESSED HSW w/F1 OR F2 ESCUTCHEON
(1) FM APPROVED FOR 4" - 6" [101.6MM - 152.4MM] CEILING TO DEFLECTOR WITH F2 ONLY.
Fig. 3
Model Fl FR56 Recessed Horizontal Sidewall sprinkler with Model Fl or F2 escutcheon
1" x 1/2" REDUCING
TEE OR El BOW
1I11::
HOLE IN CEILING
1 1/2" MAX.
FACE OF FITTING
TO FACE OF CEILING
DIMENSION
1/2" MAX.
COVER ADJUSTMENT
COVER PLATE
ASSEMBLY / 3 5/16' 0/A
SPRINKLER
CONCEALED, 1/2" ADJUSTMENT
Fig.4
Model F1 FR56/F1 FR56LL Concealed Pendent sprinkler with standard depth
1/2-inch (12.7mm) adjustment - Model COP cover plate
1 ---r---
11 15/16" DIA.4
[49.2mm]
-
(1)
4"-12"
[101. 6mm-304.8mm]
CEILING TO
DEFLECTOR
I" x 1/2 REDUCING
TEE OR ELBOW
'J T J" 0/A
2 5/16 0/A - _______ -
r' HOLE IN CEILING
CUP
00 vu 1 112 MAX.
FACE OF FITT-ING
TO FACE 0 CEILING
5/16 MAX. // 3/4
COVER ADJUSTMENT
COVER PLATE / I I
ASSEMBLY 3 5/16 0/A.
SPRINKLER
CONCEALED, 5/16" ADJUSTMENT 07EG02A
..p}g: v.rc3cJe .36 /.3tL :
5/16-inch (8.0mm) adjust
Maintenance
The Model Fl FR Series sprinklers should be inspected and
the sprinkler system maintained in accordance with NFPA
25. Do not clean sprinklers with soap and water, ammonia or
any other cleaning fluids. Remove dust by using a soft brush
or gentle vacuuming. Replace any sprinkler which has been
painted (other than factory applied) or damaged in any way.
A stock of spare sprinklers should be maintained to allow
quick replacement of damaged or operated sprinklers.
Finishes (1)
I Iinichc
Sprinkler Escutcheon over plate'11
Bronze - Chrome
Chrome Plated
_Brass
Chrome White
Polyester Plated
Coated "" White Painted
on Finishes
l Electroless Nickel Electroless Nickel
PTFE'71 PTFE Bright Brass
Lqsin lit _Brass'3> Bright Brass Black Plating
Black Plated Black Plated Black Paint
BlackkPntI2w Black Paint Oft White
Whiteihilvi 011 White Satin Chrome
_chrome Dull Chrome Dull
Other finishes and colors are available on special order, Consult the
factory for details. Custom color painted sprinklers may not retain their
UL Corrosion resistance listing. Coverplate custom paint is semi-gloss,
unless specified otherwise.
cULus Listed only.
200°F (93°C) maximum.
' cULus listed corrosion resistance' applies to SIN Numbers RA1435
(HSW), RA1485(VSW), RA1425 (Upright), RA1414 (Pendent) and
RA1415 (Pendent) in standard black or white. Corrosion resistance in
other polyester colors is available upon request.
FM Approvals finish as Polyester coated" applies to SIN Number
RA1414, RA1435 and RA1425 in standard black or white.
LPCB and VdS Approved finish applies only to RA1425, RA1414, RA1418
(VdS) and RA 1475.
cULus listed Corrosion Resistant 7
eiceaiec' r-erioeHt SpnkeF w,tn iow prattle
ment - Model CCP cover plate
Material Data
Frame: DZR Brass, GM Brass, or Low Lead Brass
Deflector: CDA Alloy 220, 260, or 510
Load Screw\Pintle: CDA Alloy 360 or 544
Cup: CDA Alloy 651 or 693
Washer: Nickel Alloy 440 or 360, coated with PTFE
Adhesive Tape
Bulb: Glass
Ordering Information
Specify:
Sprinkler Model: [Fl FR28J[F1 FR4O][F1 FR42]
[Fl FR42LL][F1 FRXLH][F1FR56][F1 FR56LL]
Sprinkler Deflector/Orientation: [Pendent][Recessed
Fendent][Upright][Conventional][Horizontal Sidewall]
[Recessed Horizontal 5idewa11][Vertical Sidewall]
Sprinkler threads: [1/2-inch NPT][ISO 7-R1/2]
Sprinkler Temperature Rating: [135°F (57°C)][155°F
(68°C)][1 75°F (79°C)][200°F (93°C)][286°F (141°C)]
Sprinkler Finish
Escutcheon Model: [F1][F2][FP]
Escutcheon Finish (where applicable)
Cover plate Model: [standard profile COP 1/2-inch
(12.7mm) adjustment][low profile COP 5/16-inch
(8.0mm) adjustment]
Cover plate Temperature Rating: [135°F (57°C) for use
with Ordinary Temperature sprinklers][165°F (74°C)
for use with Intermediate Temperature sprinklers]
Cover plate Finish
Note: When Model F1FR Series Recessed sprinklers are ordered, the
sprinklers and escutcheons are packaged separately.
Reliable ... For Complete Protection
Reliable offers a wide selection of sprinkler components. Following are some of the many
precision-made Reliable products that guard life and property from fire around the clock.
Automatic sprinklers • Deluge valves
Flush automatic sprinklers • Detector check valves
Recessed automatic sprinklers • Check valves
Concealed automatic sprinklers • Electrical system
Adjustable automatic sprinkl ers • Sprinkler emergency cabinets
'i
.1 -
Intermediate level sprinklers
Open sprinklers
Spray nozzles
Alarm valves
Retarding chambers
Dry pipe valves
Accelerators for dry pipe valves
Mechanical sprinkler alarms
Electrical sprinkler alarm switches
Water flow detectors
Sprinkler escutcheons and guards
Inspectors test connections
Sight drains
Ball drips and drum drips
Control valve seals
Air maintenance devices
Air compressors
Pressure gauges
Identification signs
Fire department connection
The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory
Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable.
Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly
qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries.
Manufactured by
Reliable Automatic Sprinkler Co., Inc. Recycled
(800) 431-1588 Sales Offices Paper Reliable (800) 848-6051 Sales Fax Revision lines indicate updated or new data,
(914) 829-2042 Corporate Offices
www.reliablesprinkler.com Internet Address CC, Prided in U.S.A. 06/15 P/N 9999970300