6269 EL FUERTE ST; ; FA080081; Permit
9/27/22,11:17 AM FA080081 Permit Data City of Carlsbad Fire Alarm Permit Job Address: 6269 EL FUERTE ST Permit Type: FALARM Parcel No: 2131221100 Lot #: 0 Reference No.: Permit No: FA080081 Status: ISSUED Applied 11/25/2008 Approved: 11/25/2008 Issued: 11/25/2008 PC #: Inspector: Project Title PACIFIC RIDGE SCHOOL TWO FIRE ALARM INSPECTIONS @ $65/EA Applicant: HIDDEN EYE SECURITY 42320 VIA NORTADA TEMECULA, CA Owner: PRS ACQUISITION&CONSTRUCTION L L C 12750 HIGH BLUFF DR #190 SAN DIEGO CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 130 0 130 0 about:blank 1/1 EN UN fA 0Q, 0 ~ . Fire alarm system cut sheets & California State Fire Marshal Listing sheets for: EXISTING MODULAR BUILDINGS 6269 EL FUERTE STREET CARLSBAD, CA 92009 No. Conierclal And Reèidentiag Alarm Services 42320 VIA NORTADA TEMECULA, CA 92590 (951)699-1827 APP VIED AS SUBilTTED — p ;e CA1AD1!!RE DEPARTMENT ... Fire Protection by Computer Design n I I Building Location : 2815 JEFFERSON STREET System 1 Contract : 41222 Data File : 41222-JE.WX2 CITY OF CARLSBAD FIRE DEPARTMENT APPROVED Subject to field inspection and required tests, notations hereon, conditions in correspondence and conformance with applica re ations. The stamping of the ipl shall not be held to permit or v tion of any law. / By Date Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve (C) Page 1 41222 JESSEE OFFICE BLDG Date 020205 City Water Supply: Cl - Static Pressure : 74.7 C2 - Residual Pressure: 18 C2 - Residual Flow : 4190 150 140 P 120 R 110 E 100 90 S 80 U 70 R 60 E 50 40 30 20 10 5001000 1500 2000 2500 3000 3500 4000 4500 FLOW ( N" 1.85 ) Dl - Elevation : 3.465 02-System Flow : 344.13 D2 - System Pressure : 72.099 Hose (Adj City) Hose ( Demand) : 250 D3 - System Demand : 594.13 Safety Margin : 1.073 - - - - 130 - C2 _ Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary t I. Page 41222 JESSEE OFFICE BLDG 2 Date 020205 Fitting Legend Abbrev. Name 1/2 % 1 1% 1% 2 2% 3 31/2 4 5 6 8 10 12 14 16 18 20 -24 E 90' Standard Elbow 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 G Generic Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 T 90 Flow Thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure / Flow Summary - STANDARD Page 3 41222 JESSEE OFFICE BLDG Date 020205 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. 26 10.0 5.6 11.23 na 18.77 .1500 120 7.000 25 10.0 5.6 10.33 na 18.0 .1500 120 7.000 23 10.0 5.6 11.09 na 18.65 .1500 120 7.000 24 10.0 12.24 na 22 10.0 5.6 19.11 na 24.48 .1500 120 7.000 16 10.0 19.69 na 17 10.0 5.6 19.61 na 24.8 .1500 120 7.000 18 10.0 5.6 19.65 na 24.83 .1500 120 7.000 19 10.0 5.6 20.07 na 25.09 .1500 120 7.000 20 10.0 5.6 21.1 na 25.72 .1500 120 7.000 21 10.0 5.6 23.25 na 27.0 .1500 120 7.000 3 10.0 17.41 na 13 10.0 5.6 18.0 na 23.76 .1500 120 7.000 14 10.0 19.09 na 15 10.0 20.95 na 1 10.0 5.6 10.33 na 18.0 .1500 120 7.000 2 10.0 11.42 na 4 10.0 5.6 17.31 na 23.3 .1500 120 7.000 5 10.0 5.6 17.31 na 23.3 .1500 120 7.000 6 10.0 17.48 na 7 10.0 5.6 17.64 na 23.52 .1500 120 7.000 8 10.0 5.6 19.8 na 24.92 .1500 120 7.000 9 10.0 24.05 na 10 10.0 55.07 na 11 10.0 55.51 na 12 10.0 56.99 na 1ST 10.0 62.35 na BOR 0.5 67.75 na P21) -3.0 69.45 na BF2 2.0 67.47 na BF1 2.0 71.48 na HOSE -3.0 73.82 na 250.0 SRC 2.0 72.1 na The maximum velocity is 21.31 and it occurs in the pipe between nodes 9 and 10 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard Page 4 41222 JESSEE OFFICE BLDG Date 020205 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes ****** Point Qt Pf/UL Eqv. Ln. Total Pf Pn 26 18.77 1.049 IT 5.0 3.660 11.233 K Factor = 5.60 to 120 0.0 5.000 0.0 24 18.77 0.1157 0.0 8.660 1.002 Vel = 6.97 0.0 18.77 12.235 K Factor = 5.37 25 18.00 1.049 IT 5.0 5.200 10.332 K Factor =5.60 to 120 0.0 5.000 0.0 2 18.0 0.1071 0.0 10.200 1.092 Vel = 6.68 - 0.0 18.00 11.424 K Factor = 5.33 23 18.65 1.049 IT 5.0 5.000 11.092 K Factor 5.60 to 120 0.0 5.000 0.0 24 18.65 0.1143 0.0 10.000 1.143 Vel = 6.92 24 18.77 1.049 IT 5.0 7.660 12.235 to 120 0.0 5.000 0.0 6 37.42 0.4147 0.0 12.660 5.250 Vel = 13.89 0.0 37.42 - 17.485 K Factor = 8.95 22 24.48 1.049 21 10.0 16.120 19.106 K Factor= 5.60 to 120 0.0 10.000 0.0 924.480.1891 0.026.120 4.940 Vel=9.09 0.0 24.48 24.046 KFactor=4.99 16 -14.86 1.61 IT 8.0 1.000 19.691 to 120 0.0 8.000 0.0 17-14.86-0.0093 0.09.000-0.084 Vel=2.34 17 24.79 1.61 0.0 10.410 19.607 K Factor =5.60 to 120 0.0 0.0 0.0 18 9.930.0044 0.010.410 0.046 Vel= 1.56 18 24.83 1.61 0.0 9.370 19.653 K Factor =5.60 to 120 0.0 0.0 0.0 19 34.76 0.0449 0.0 9.370 0.421 Vel = 5.48 19 25.09 1.61 0.0 8.330 20.074 K Factor =5.60 to 120 0.0 0.0 0.0 20 59.850.1227 0.08.330 1.022 Vel =9.43 20 25.72 1.61 0.0 9.040 21.096 K Factor = 5.60 to 120 0.0 0.0 0.0 21 85.570.2378 0.0 9.040 2.150 Vel=13.49 21 27.00 1.61 2E 8.0 65.700 23.246 K Factor = 5.60 to 120 IT 8.0 16.000 0.0 11112.570.3949 0.0 81.700 32.266 VeI= 17.74 0.0 112.57 55.512 KFactor= 15.11 3 57.70 1.61 0.0 5.200 17.408 to 120 0.0 0.0 0.0 13 57.7 0.1146 0.0 5.200 0.596 Vel = 9.09 13 23.77 1.61 1E 4.0 1.000 18.004 K Factor =5.60 to 120 0.0 4.000 0.0 14 81.47 0.2172 0.0 5.000 1.086 Vel= 12.84 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard 41222 JESSEE OFFICE BLDG Page 5 Date 020205 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn 14 0.0 2.157 0.0 11.500 19.090 to 120 0.0 0.0 0.0 16 81.47 0.0523 0.0 11.500 0.601 Vel= 7.15 16 14.86 2.157 IE 6.153 11.500 19.691 to 120 0.0 6.153 0.0 15 96.33 0.0712 0.0 17.653 1.257 Vel = 8.46 15 0.0 1.61 2E 8.0 105.750 20.948 to 120 iT 8.0 16.000 0.0 12 96.33 0.2960 0.0 121.750 36.043 Vet= 15.18 0.0 96.33 56.991 KFactor= 12.76 1 18.00 1.049 IT 5.0 5.200 10.332 K Factor =5.60 to 120 0.0 5.000 0.0 2 18.0 0.1071 0.0 10.200 1.092 Vel = 6.68 2 18.00 1.049 iT 5.0 10.500 11.424 to 120 0.0 5.000 0.0 3 36.0 0.3861 0.0 15.500 5.984 Vet = 13.36 3 -57.70 1.61 0.0 5.200 17.408 to 120 0.0 0.0 0.0 4 -21.7 -0.0188 00 5.200 -0.098 Vet = 3.42 4 23.29 1.61 0.0 9.370 17.310 K Factor =5.60 to 120 0.0 0.0 0.0 5 1.59 0.0001 0.0 9.370 0.001 Vet = 0.25 5 23.30 1.61 0.0 7.160 17.311 K Factor= 5.60 to 120 0.0 0.0 0.0 6 24.89 0.0243 0.0 - 7.160 '0.174 Vet = 3.92 6 37.42 1.61 0.0 1.160 17.485 to 120 0.0 0.0 0.0 7 62.31 0.1319 0.0 1.160 0.153 Vet = 9.82 7 23.52 1.61 0.0 9.040 17.638 K Factor= 5.60 to 120 0.0 0.0 0.0 8 85.83 0.2392 0.0 9.040 2.162 Vet = 13.53 8 24.92 1.61 0.0 11.080 19.800 -- K Factor =5.60 to 120 0.0 0.0 0.0 9 110.75 0.3832 0.0 11.080 4.246 Vel =-.1 7.45 9 24.48 1.61 1E 4.0 51.950 24.046 to 120 0.0 4.000 0.0 10_135.230.5545 0.0 55.950 31.022 Vel =21.31 10 0.0 2.635 0.0 8.830 55.068 to 120 0.0 0.0 0.0 11135.230.0503 0.0 8.830 0.444 Vel =7.96 11 112.57 2.635 0.0 9.580 55.512 to 120 0.0 0.0 0.0 12247.80.1544 0.0 9.580 1.479 Vet _14.58 12 96.32 2.635 1E 8.237 10.660 56.991 to 120 0.0 8.237 0.0 1ST 344.12 0.2834 0.0 18.897 5.355 Vet= 20.25 1ST 0.01 4.26 2E 26.334 21.000 62.346 to 120 0.0 26.334 4.114 BOR 344.13 0.0273 0.0 47.334 1.294 Vet = 7.75 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard 41222 JESSEE OFFICE BLDG Page 6 Date 020205 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftngs Pe Pv Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn BOR 0.0 6.16 2E 40.168 13.500 67.754 to 140 0.0 40.168 1.516 P2D 344.13 0.0034 0.0 53.668 0.182 Vel = 3.70 P2D 0.0 6.08 1E 730.243 36.000 69.452 to 150 0.0 21.411 -2.166 BF2 344.13 0.0032 0.0 57.411 0.184 Vel = 3.80 BF2 0.0 6.16 0.0 2.000 67.470 to 140 0.0 0.0 4.000 BF1 344.13 0.0035 0.0 2.000 0.007 Vel = 3.70 BF1 0.0 6.08 0.0 56.000 71.477 to 150 0.0 0.0 2.166 HOSE 344.13 0.0032 0.0 56.000 0.179 Vel = 3.80 HOSE 250.00 6.08 iT 1460.486 0.001 73.822 Qa = 250.00 to 150 1G 121.707 50.469 -2.166 SRC 594.13 0.0088 0.0 50.470 0.443 Vel = 6.57 0.0 594.13 72.099 KFactor= 69.97 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Project: Jesse Office Building ~GN 4ZPR_OT ET!ON 4883 Ronson Court, SL,ite Permit No.: 041262 Date: San Diego. California 92111 DE (Fax) 858.751.2933 Review No.: 041262-3 By: SML (Phone) 858.751.2930 CO I Contractor: Gardner Pipe &Mechanical Fire Protection System Submittal Review Summary The above-referenced plans and calculations have been reviewed are recommended for approval to the Carlsbad Fire Department. & /~ s '-/' < Date CC: City of Carlsbad, fire Prevention Division Project: Jesse Office Building PROTECTI IG 4883 Ronson Court, Suite ' Permit No.: 041262 5/12/05 *44rSan Diego, California 92111 (Phone) 858.751.2930 DESIGN (Fax) 858,751.2933 Review No.: 041262-2 By: CONSULTI Contractor: Gardner Pipe & Mechanical Fire Protection System Submittal Review Summary Please note that all revisions to plans and/or calculations shall be highlighted with an architectural cloud. All inquiries and re-submittals shall be sent directly to: Protection Design & Consulting 4883 Ronson Court, Suite P San Diego, California. 92111 (858) 751-2930 (Phone) (858) 751-2933 (Fax) The above-referenced plans and calculations have been reviewed and certain information is still not shown. Prior to recommending approval to the Carlsbad Fire Department, the following shall be provided: PLANS U It does not appear that all fire-rated walls have been identified. Show location of fire-top assemblies where required. U The hanger details on the plans are not in accordance with the TrussJoist Corp. technical data provided. Show details on plans that exactly comply: offset Sammy fasteners from centerline of bottom chord (see DC #15 and #18); Sammy "Sidewinder" attachment to top chord not shown by manufacturer (see TJC #20). U Piping is noted as running at elevations ranging from 23" to 29" below deck and the actual depth of structural members is not shown on plans section. If hangers are attached to sides, or at or near upper chords of joists, hangers will exceed 6" rod length. Please furnish adequate information to verify hanger type, length and valid omission of lateral sway bracing. U No details have been furnished for sway brace attachment to DI. Calculation of longitudinal brace is accepted, pending approved detail for attachment. U End-of-line restraint locations are incomplete. Add asterisks at all locations or if it's easier, furnish a general note that all branch line ends and arm-overs will be furnished with restraints. Please resubmit revised plans only. Hydraulic calculations and materials submittal are accepted. Dat CC: City of Carlsbad, Fire Prevention Division MUDRY& ASSOCIATES 12752 Valley View Street, Suite D Garden Grove, California 92845 (714) 373-5741 Fax (714) 373-5781 E-mail: fpe@mudry.us HYDRANT FLOW TEST RESULTS Date: Time: /0; 10 49 Location: Hydrant identification: Static and Residual Test /4i4fr, z Flow Test Z ? s/. Pitot Reading: 4 '7 PSI c 77 ev4 T/OA) - Hydrant Orifice Diameter: 4. Coefficient: , Static Pressure: b PSI Residual Pressure: 7 PSI Observed Flow: Calculated Flow @ 20 PSI 4/ '90 GPM Test Witnessed by: /7 414 Z-624, Please be reminded that the flow test results indicate the capacity of the water system at the time the test was made. Since the capacity of the water system may vary as a result of many factors, including changes in demand placed on the system by other users, it is recommended that you give adequate consideration to the possible variations when performing calculations and analysis based upon any given flow test results. Project: Jesse Office Building PROTECTION 4883 Ronson Court, Suite ' Permit No.: 041262 Date: 4/20/0 San Diego, California 92151 (Phone) 858.751.2930 0ESIGN& I Review No.: 041262-1 By: SML 0NSULNG (Fax) 858.751.2933 Contractor: Gardner Pipe &Mechanical Fire Protection System Submittal Review Summary Please note that all revisions to plans and/or calculations shall be highlighted with an architectural cloud. All inquiries and re-submittals shall be sent directly to: Protection Design & Consulting 4883 Ronson Court, Suite P San Diego, California. 92111 (858) 751-2930 (Phone) (858) 751-2933 (Fax) Wpo The above-referenced plans and calculations have been reviewed and certain information is unclear or not shown. In general, the basis of design is in reasonable compliance with NFPA 13. However, prior to recommending approval to the Carlsbad Fire Department, the following shall be provided: PLANS U Hazard Group(s) and Density: Carlsbad Fire Department requires "spec" office buildings to be protected for Ordinary Hazard, Group 2. Plans as submitted are for Light Hazard in upper/lease areas. Furnish calculations for .20/1500 ft2 with 250 GPM hose stream allowance. U Full height cross section: note slope of mansard roof and identify concealed spaces (if any) where sprinklers are not installed (section shows condition that could be viewed as an envelope on the bottom of composite wood joists. U Show location and call-out of all fire-rated walls and separations. U Show location of draftstops in attics, if any or note on plans that no draftstops provided. U Show/note size of city main in street and whether dead-end or circulating. U If dead end, show/note direction and distance to nearest circulating main. (Recommend to include vicinity map and more detailed site plan.) U Furnish technical data on piping or note pipe type and schedule of wall thickness on plans. U Show/note types of fittings and joints and location of all welds and bends. U Verify that hanger and bracing connections are appropriate/approved for type of structure, i.e. composite wood joists. Furnish details of methods of attachment to CWJ's and max. load bearing values based on angle of bracing. U Verify that end-of-line and intermediate restraints are furnished as required, and show locations on plans with symbols to distinguish from conventional hanger locations. U Note type and location of alarm bell, i.e. elevation above finished grade. No site plan furnished - it isn't possible to consider bell location shown on plan. U Relocate inspector's test connection to remote end of upper floor system, per Carlsbad requirements. U Include information for the hydraulic data nameplate U Include graphic representation of the scale used on all plans - scale callouts aren't legible attic plan and section. U Show sway bracing locations, including 4-way braces on all risers. No lateral bracing is shown - verify and show/note on plans that lateral bracing is excluded only where rod hangers do not exceed 6". U Calculation of loads for sizing and details of sway bracing compared to factory data on composite joists. U Riser detail shows a pressure relief valves open to atmosphere; make provisions to discharge to an approved location to protect against water damage. OR U Riser detail is shown for vertical installation under footing and through structural slab. Carlsbad requires that risers pass over footings only and service entry shall be through exterior wall above grade. Revise/clarify arrangement of riser. U Show location of static and residual hydrants that were used in flow tests. U Fire department connection is schematically shown on inlet side of backflow; revise to discharge side. U Show/note supply of spare heads and wrenches required. U Furnish notes/details showing adequate clearances around piping penetrations, based on pipe size. U Note locations of fire sealant at penetrations through rated assemblies, including floors. HYDRAULIC CALCULATIONS U Furnish documentation of flow test data, with written confirmation from testing agency, including source of information, date, time, location of test hydrants and system elevation relative to test. U Furnish Technical Data Sheets for all sprinklers calculated. U Furnish technical data sheet for exact make/model of backflow assembly installed, for confirmation of hydraulic calculations. U Hose allowance for parking garage should be 250 GPM, not 100 as submitted. CC: City of Cárlsbad,fFire Prevention Division Fire Prevention Division 1635 Faraday Avenue, Carlsbad CA 92008 Phone (760) 602-4666 Fax (760) 602-8561 FAX TRANSMITTAL - TO: z1) FROM:__________________ COMPANY________________ FAX NO: 75/97 3 FAX NO: (76.0199H561 PHONE NO: PHONENO.- -------------.. .......... COMMENTS ?cz; 0 FOR-YOUR INFORMATION FORMATION YOU REQUESTED O PLEASE REVIEW AND ADVISE O PLEASE COMMENT O REPLY REQUESTED BY.. Applicant ID No: 983340-001 Service Center No 1 Expires: 31 -MAR-2009 CERTIFICATE OF COMPLIANCE THIS IS TO CERTIFY that the Alarm Service Company indicated below is included by Underwriters Laboratories Inc. (UL) in its Product Directories as eligible to use the UL Listing Mark in connection with Certificated Alarm Systems. The only evidence of compliance with UL's requirements is the issuance of a UL Certificate for the Alarm System and the Certificate is current under UL's Certificate Verification Service. : Listed Service From: TEMECULA, CA Alarm Service Company (983340-001) - Service Center (983340-001) lIES HE 42320 VIA NORTADA 42320 VIA NORTADA TEMECULA CA 92590 TEMECULA CA 92590 The Alarm Service Company is Listed in the following Certificate Service Categories: File - Vol No. CCN Listing Category I S8057 -1 ULJFX [Signal and Fire Alarm Equipment and Services] (Protective Signaling Services) Central Station / I ***THIS CERTIFICATE EXPIRES ON 31-MAR-2009 *** "LOOK FOR THE UL ALARM SYSTEM CERTIFICATE" Engineering anager :238 ForrncS.CC 24-MAR-2008 ------ Underwriters Laboratories Inc. ® Applicant ID No: 892912-001 Service Center No 1 Northbrook, 11. Santa Clara, CA Melville, NY Research Triangle Park, NC Expires: 31-MAR-2009 Camas, WA A not-for-profti organization dedicated to public safety and committed to quality seivice CERTIFICATE OF COMPLIANCE THIS IS TO CERTIFY that the Alarm Service Company indicated below is included by Underwriters Laboratories Inc. (UL) in its Product Directories as eligible to use the UL Listing Mark in connection with Certificated Alarm Systems. The only evidence of compliance with UL's requirements is the issuance of a 'j UL Certificate for the Alarm System and the Certificate is current under UL's Certificate Verification Service. > Listed Service From: LONG BEACH, CA Alarm Service Company: (892912-001) Service Center: (892912-001) GENERAL MONITORING SERVICES INC GENERAL MONITORING SERVICES INC 1127 LOMA AVE 1127 LOMA AVE LONG BEACH CA 90804 LONG BEACH CA 90804 The Alarm Service Company is Listed in the following Certificate Service Categories: File - Vol No. CCN Listing Category S7894 -1 UUFX [Signal and Fire Alarm Equipment and Services] (Protective Signaling Services) Central Station 5) S) ***THIS CERTIFICATE EXPIRES ON 31-MAR-2009 *** - '1-00KFOF3 THE UL ALARM SYSTEM CERTIFICATEt' . 5- d4i;ewll I!PIFVM M&eT s) 13-MAR-2008 01998UL Form CS-CC ) —5— — -1 __ J ® APPROVED 429-92-E Vol. Vi MEA Farenhyt IFP-1 000/IFP-1 000HV The IFP-1 000 and IFP-1000HV are intelligent analog/addressable fire alarm control panels (FACP5). The basic IFP-1000 system has one signal line circuit (SLC) loop that supports up to seven 5815XL signal line circuit expanders.The IFP-1000HV offers the same functionality and features as the lFP-1000 but is configured for 240 VAC operation. IFP-1000/HV has six on-board FlexputTM circuits that can be configured for auxiliary power, notification outputs, or for conventional smoke detector inputs (Class A or Class B). The FACP also has a built-in, dual-line digital fire communicator, Form C trouble relay, and two programmable Form C relays. The firmware has powerful features such as detector sensitivity, day/night thresholds, drift compensation, pre-trouble maintenance alert, and calibration trouble alert. lFP-1000/HV supports a variety of devices, including RA-1000 remote annunciator, 5824 serial/parallel printer interface module (for printing system reports), RPS-1000 intelligent power module, and Hochiki or Intelligent Device Protocol (IDP) devices. Features Built-in support for up to 127 Hochiki devices or 99 IDP detectors and 99 IDP modules, expandable to 1016 Hochiki devices or 792 IDP detectors and 792 IDP modules Uses standard wire—no shielded or twisted pair required Built-in UL listed digital communicator for remote reporting of system activity and system programming Central station reporting by point or by zone Supports Class B (Style 4) and Class A (Style 6 or Style 7) configuration for SLC, and SBUS Distributed, intelligent power Sensor sensitivity settings, day/night sensitivity setting and automatic drift compensation FlexputTM I/O circuits configurable for auxiliary power, notification outputs, or conventional smoke detector inputs. Notification circuits can be configured as Class A (Style Z) or Class B (Style Y). 2- and 4-wire smoke detectors can be configured as Class A (Style D) or Class B (Style B) Built-in annunciator with a backlit 80-character LCD display RS-485 bus provides communication to system accessories Built-in RS-232 and USB interface for programming Upload or download programming, event history, or detector status onsite or from a remote location using a PC and 5650/5651 Silent Knight Software Suite (SKSS) Improvements in SKSS delivers five times faster upload/downloads Built-in Form C trouble relay rated at 2.5 amps at 27.4 VDC Two built-in Form C programmable relays rated at 2.5 amps at 27.4 VDC Individual addressable devices can be tested SLC device locator can locate a single or multiple devices on a SLC loop System automatically tests addressable devices 13 preset notification cadence patterns (including ANSI 3.41) and four user programmable patterns SILENT 7550 Meridian Circle Maple Grove, Mn 55369-4927 KNIGHT 763-493-6455 1-800-328-0103 Fax: 763493-6475 by Honeywell hup://w.farenhlt.com Analog/Addressable Fire Alarm Control System IFP-1000 Programmable to automatically display initial event first or display tally of system events Built-in synchronization for appliances from AMSECO, Gentex®, Faraday, System Sensor®, and Wheelock® Acknowledge function allows operator to keep track of event status Jumpstart® auto-programming Modular design Nonvolatile event history stores up to 1000 events 125 software zones and 250 output groups 6 amp power supply and maximum charging capacity of 35 amp hours (An additional cabinet enclosure is required for batteries in excess of 18 amp hours) Programmable date setting for Daylight Saving Time Plex-1 door option combines a dead front cabinet door with a clear window, limiting access to the panel while providing single button operation of the reset and silence functions P/N 350093 Rev H 04/21/06 Copyright® 2006 Silent Knight Flexput is a Trademark of Silent Knight Jumpstarto is a Registered Trademark of Silent Knight Installation The IFP-1000/HV can be surface or flush mounted. Compatibility The lFP-1000/HV SLC supports multiple device types of the same protocol: Hochiki IDP You cannot mix Hochiki and IDP devices on a FACP. However, any combination of addressable devices of the same protocol can be used on the IFP-1000/HV. Specifications Physical Flush Mount Dimensions: 14.5W x 24.75"H x 3.9"D (36.8 W x 62.9 H x 9.8 D cm) System Silenced (Yellow): On when an alarm, trouble or supervisory condition has been silenced but not yet cleared System Power (Green): Flashes for AC failure; solid when power systems are normal Telephone Requirements: FCC Part 15 & Part 68 approved Jack: RJ31X (two required) Approvals NFPA 13, NFPA 15, NFPA 16, NFPA 70, & NFPA 72: Central Station; Remote Signalling; Local Protective Signalling Systems; Auxiliary Protected Premises Unit; & Water Deluge Releasing Service. Suitable for automatic, manual, waterflow, sprinkler supervisory (DACT non-coded) signalling services. Other Approvals: UL Listed; CSFM 7170-0559: 135; MEA 429-92-E Vol. VI; FM Approved Overall Dimensions: Weight: 28 lbs. (12.8 kg) Color: Red 16.2W x 26.4"H x 4.2"D (40.6W x 67 H x 11.8 D cm) Ordering Information IFP-1000 Intelligent Fire Alarm Control Panel. IFP-1000HV Intelligent Fire Alarm Control Panel. High voltage (240 VAC). Environmental Operating Temperature: 32°F - 120°F (0°C - 49°C) Humidity: 10% - 93% non-condensing Electrical IFP-1000 Primary AC: 120 VRMS @50/60 Hz, 2.7A IFP-1000HV Primary AC: 240 VRMS @50/60 Hz, 1.4A Total Accessory Load: 6A @ 27.4 VDC power-limited Standby Current: 140 mA Alarm Current: 260 mA Battery Charging Capacity: 7 to 35 AH Battery Size: 18 AH max. allowed in control panel cabinet. Larger capacity batteries can be housed in RBB accessory cabinet. Flexput Circuits Six circuits that can be programmed individually as: Notification Circuits: 3A per circuit @ 27.4 VDC, power-limited Auxiliary Power Circuits: 3A per circuit @ 27.4 VDC, power- limited Initiation Circuit: 100 mA per circuit @ 27.4 VDC, power-limited Indicator Lights General Alarm (Red): Flashes when in alarm; solid when alarm silenced Supervisory (Yellow): Flashes when a supervisory condition exists; solid when supervisory silenced System Troubles (Yellow): Flashes when a trouble condition exists; solid when trouble silenced SBUS Accessories RA-100 Remote Annunciator. Similar in operation and appearance to FACP annunciator. Gray. RA-100R Remote Annunciator. Similar in appearance and operation to FACP annunciator. Red. RA-1000 Remote Annunciator. Four line LCD annunciator with 20 characters per line. 5815XL Signal Line Circuit (SLC) Expander. RPS-1000 Intelligent Power Module. 5496 Intelligent Power Module. 5824 Serial/Parallel Printer Interface Module. 5880 LED I/O Module. 5865-3 & 5865-4 LED Fire Annunciators. 5883 Relay Interface Board. Hochiki and IDP Devices See the specification sheets listed below for a complete listing of the Hochiki and IDP devices. 350360 Hochiki Devices Specification Sheet 350361 Intelligent Device Protocol Devices Specification Sheet Miscellaneous Accessories 5650/5651 Silent Knight Software Suite. Provides programming, upload/download, and event reporting. 5670 Silent Knight Software Suite. Provides facility monitoring. Plex-1 Door Accessory. Dead front cabinet door with clear window to limit access to panel. RBB Remote Battery Box Accessory Cabinet. Use if backup batteries are too large to fit into FACP cabinet. Dimensions: 16" W x 10" H x 6" D (406 mm W x 254 mm H x 152 mm D) SILENT This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications KNIGHT or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 7550 Meridian Circle Suite 100, Maple by Honeywell Grove, Mn 55369-4927. Phone: (800) 328-0103, Fax: (763) 493-6475. Made in the U.S.A. Farenhyt For Remote Annunciation RA-1000 Remote Annunciator The RA-1000 Remote Annunciator can be used to operate and pro- gram Farenhyt Fire Control Panel. The RA-1000's keypad and dis- play match the built-in annunciator of the IFP-1 000 control panel. The remote annunciator connects to the control panel via the RS- 485 system bus. When the system is in normal operation and has AC power, the Power LED is lit and all other LEDs are off. The other LEDs turn on as alarms, supervisories, troubles, system silenced and AC power losses occur. Features 80-character backlit LCD display (4 lines with 20 characters each) Tactile/audible feedback Accepts user codes or fire fighter's key Larger keypad buttons for system Reset and Silence RS-485 interface to panel Can be flush- or surface mounted. Trim ring available for sur- face mounting. Operation and appearance is identical to IFP-1000 built-in annunciator Supports simultaneous use by multiple users from up to 8 sepa- rate RA-1000s on-board piezo sounder audibly indicates alarms, troubles, and supervisories Five Status LEDs for; alarms, supervisory, trouble, silence and AC power indications. UL listed, complies with NFPA 72 CSFM approved MEA approved FM approved Wiring lengths up to 6000 ft. from the control panel Specifications Operating Voltage: 24 VDC Standby Current: 20 mA Alarm Current: 25 mA Maximum Per System: 8 Operating Temperature: 32° F to 120° F (0° C to 49° C) Mounting: Surface or Flush Wiring Distance: Up to 6,000 feet from control panel (depending on wiring method) 7550 Meridian Circle D SILENT Grove, Mn 55369-4927 KNIGHT 763-493-6435 800-446-6444 Fax: 763-493-6475 < > 1A APPROVED UDO MEA 429-92-E Vol. 9 Dimensions: Height: 7-3/8" (18.73 cm) Width: 9-1/8" (23.18 cm) Depth: 1-1/2" (3.81 cm) Colors: Lt. Gray (RA-1000) Red (RA-1000R) Compatible FACPs: IFP-1000 IFP- 100 P/N 350071, 11/01 Copyright © 2001 Silent Knight http://www.farenhyt.com RA-1 000 80 Character Display LED Status Indicators Large Buttons for System Reset and Silend Fire Fighter's Key Numeric' I Keypad Ergonomic Designed Keypad IFP-1000 FACP RA-1000 Am Up to 8 RA-1000 per system 80-character backlit LCD display (4 lines with 20 characters each) Wiring lengths up to 6000 ft from the control panel 7550 Meridian Circle, Maple Grove, MN 55369-4927 D SILENT 1-800-446-6444 or in Minnesota 763-493-6435 KNIGHT FAX: 763-493-6475 World Wide Web: http://www.farenhyt.com Made in the U.S.A. 6 Amp Intelligent Distributed Power Module MEA APPROVCD > 429-92.E Vol. IX RPS-1 000 Compatibility RPS-1000 is compatible with the following FACPs: IFP-1000 IFP-100 Installation RPS-1000 can be surface or flush mounted. Farenhyt RPS-1 000 RPS-1000 intelligent distributed power module adds 6.0 amps of power, six FlexputTM I/O circuits, and two Form C relay circuits to a compatible Farenhyt addressable system. RPS-1 000 connects to the FACP via the RS-485 system bus allowing up to an additional 6,000 feet of wiring. Up to eight RPS-1000s can be used per system. Each RPS-1000 is optically isolated providing ground loop isolation and transient protection. RPS-1000 supports its own backup battery and monitors the AC power. The Flexput circuits can be programmed as notification appliance circuits, continuous, resettable, or door holder power, or as conventional initiation circuits for 2 or 4-wire smoke detectors and contact devices (e.g. pull stations). Features Six onboard Flexput circuits programmable for: - Notification appliance circuits (Class B/Style Y & Class A/Style Z) - Conventional initiation circuits (Class B/Style B & Class A/Style D) both 2- and 4-wire -Auxiliary power (for door holders, continuous power, or resettable power) 6.0 amps output power Supports Class A (Style 6) and Class B (Style 4) configuration of the SBUS Two Form C programmable relays rated at 2.5A @ 24 VDC Ground loop isolation and transient protection Provides SBUS optical isolation and re-conditions the RS-485 signal Built-in synchronization for appliances from AMSECO, Gentex®, Faraday, System Sensor, and Wheelock® Up to 6,000 foot wiring distance from the RPS-1000 Battery charging capacity is 35 Ah Large cabinet size can house two 18 Ah backup batteries or RBB accessory cabinet can house battery sizes larger that 18 Ah Room to mount two 5815XL SLC expander modules 7550 Meridian Circle SILENT Maple Grove, Mn 55369-4927 KNIGHT 763-493-6455 1-800-328-0103 Fax: 763-493-7475 by Honeywell hffp://w.farenhyt.com P/N 350070 Rev 0 02/06 Copyright © 2006 Silent Knight Flexput is a Trademark of Silent Knight Programmable for NACs, Auxilary Power, or Conventional Initiation Input Circuits (2-or 4.wlre) RPS-1000-1 RM Programmable for NACs, C Programmable for NACs, L1, 0 Auxilary Power, or Programmable Initiation 00 Auxilary Power, or 00 Input Circuits (2- or 4-wire) Conventional initiation Input Circuits (2-or 4-wire) WWU) 111111 iiI 5815XL RA-1000s 5824 L_ SLC Devices au__r I RPS10002 SBUS To Next I I RPS-1000 5815XL. RA-1000 SLC Devices Specifications Electrical Primary AC: 120 VRMS @ 60 Hz, 2.5A, or 240 VRMS @ 60 Hz, 1.4A Total Accessory Load: 6A @ 24 VDC Standby Current: 40 mA Alarm Current: 160 mA Flexput Circuits: Notification: 3 amps per circuit (6A system total) Initiation: 100 mA power limited @ 24 VDC Physical Mounting Dimensions: 14.5"W x 24.75"H x 3.9"D (36.8 cm W x 62.9 cm H x 9.8 cm D) Overall Dimensions: 16.1"W x 26.4"H x 4.1"D (40.6 cm W x 67 cm H x 11.8 cm D) Color: Red Environmental Operating Temperature: 32°F - 120°F (0°C - 49°C) Humidity: 10% - 93% non-condensing Approvals UL 864 NFPA 13, NFPA 15, NFPA 16, NFPA 70, NFPA 72, & NFPA 101 CSFM MEA 429-92-E Vol. IX FM Ordering Information RPS-1000 Intelligent Distributed Power Module. Specify 120 VAC or 240 VAC operation when ordering. Accessories RBB Remote Battery Box Accessory Cabinet. 16" W x 10" H x 6" D (406 mm W x 254 mm H x 152 mm D) 5815XL SLC Expander Module SILENT This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications KNIGHT or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 7550 Meridian Circle Suite 100, Maple by Honeywell Grove, Mn 55369-4927. Phone: (800) 328-0103, Fax: (763) 493-6475. Made in the U.S.A. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7170-0559:135 Page 1 of 2 CATEGORY: Control Unit (High-Rise) LISTEE: Silent Knight Security, 7550 Meridian Circle, Maple Grove, MN 55369 Contact: Michael Mclsaac (763) 493-6400 FAX (763) 391-5464 DESIGN: Models 5820, *5820xL *lFP..1000 Fire Alarm Control Units. Power limited, automatic, manual, local, remote station, central station, waterfiow, water releasing and sprinkler supervisory service. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: 5820, 5820XL, IFP-1000 *058200P 5815/5815XL 7628 lntelliknight 5820 5860/5860R/RA- 1000 5496 5824 5895/5895XL/RPS-1000 5865-3/5965-4 5880 5883 SD 50 0-AN M SD500-LIM SD 50 5-6 lB SD-500 SDM RA-100 3158 5220 *122365 *AB33 *5897 *5898 *058601 Control Units Motherboard Analog Loop Expander EOL Resistor Enclosure Annunciator Power Module Serial/Parallel Interface Power Expander/Supply LED Annunciator LED 10 Module Relay Interface Board Addressable Notification Module Line Isolation Module Isolation Base Smoke Detector Module Remote Reverse Polarity Module Direct Connect Module Enclosure Battery Cabinet Power Supplies User Interface RATING 120 VAC Primary, 24 VDC Secondary INSTALLATION In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. Rev. 08-1 7-2006 jw Listing No. 7170-0559:135 Page 2 of 2 APPROVAL: Listed as control units for use in high-rise structures when used in conjunction with Model SKE-360 Voice-Tone Evacuation Unit (CSFM Listing No. 6912-0559:122); EVAX Audio Adjunct System Models EVA)(-25(CSFM Listing No. 06911-1446:100), EVA)(-50 or EVAX- 50E (CSFM Listing No. 06911-1446:102); EVX-2ZA or EVX-4Z Zone Splitters (CSFM Listing No. 06912-1446:101); HMX-MP or HMX-DP Voice Evacuation System (CSFM Listing No. 06911-1446:103), two-way firefighter telephone and separately listed electrically and functionally compatible initiating and indicating devices. Also suitable for non-high-rise applications where the voice evacuation and two-way firefighter telephone are not required. Refer to listee's Installation Instruction Manual for details. These control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL-864, gth Edition Standards. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. Rev. 08-17-2006jw 11 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 6, 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering Division Addressable Photoelectric Smoke Detector & Photoelectric Smoke with Thermal MEA 225-02.E vol. v lOP-Photo (Base Not Included) Compatibility The lDP-Photo and lDP-Photo-T are compatible with the following lDP-series detector bases: lDP-6AB 6" Mounting Base SSB501 4" Mounting Base* SSB224BI 6" Isolator Base* SSB224RB 6" Relay Base* SSB501BHT 6" Temporal Sounder Base* The IDP-Photo and IDP-Photo-T are compatible with the following FACPs: lFP-1000 Intelligent Fire Panel lFP-100 Intelligent Fire Panel IFP-50 Intelligent Fire Panel * For ordering purposes, an SS has been added to the System Sensor part numbers. Example—System Sensor PN for SSB501 is B501. Farenhyt IDP-Photo & IDP-Photo-T The IDP-Photo is a photoelectric smoke detector and the IDP-Photo-T is a photoelectric smoke detector with thermal. These plug in smoke detectors, with integral communication, provide features that surpass conventional detectors and are for use with Silent Knight IFP-series fire alarm control panels (FACPs). Detector sensitivity can be programmed from the FACP software. Sensitivity is continuously monitored and reported to the FACP. Point ID capability allows each detector's address to be set with rotary address switches, providing exact detector locations for selective maintenance when chamber contamination reaches unacceptable levels. IDP-Photo and IDP-Photo-T have a unique optical sensing chamber that is engineered to sense smoke produced by a wide range of combustion sources. In the lDP-Photo-T, dual electronic thermistors add 135°F (57°C) thermal technology to maximize detection. Features Sleek, low-profile design Reliable analog communications for trouble-free operation Age resistant polymer housing Dual electronic thermistor design on the IDP-Photo-T Superior EMI resistance for reliability Simple field cleaning for code compliance Variety of mounting options to meet any application Dual LED indicators for 3601 visibility Detector transmits signal to indicate maintenance is required Optional remote LED annunciator (PN SSRA400Z; System Sensor® PN RA400Z) Plug-in mounting provides ease of installation Tamper-proof feature available on mounting bases Listed for use in duct applications Rotary address switches for fast installation UL Listed Installation The lDP-Photo and IDP-Photo-T plug into a compatible IDP-series detector base. SILENT 7550 Meridian Circle Maple Grove, Mn 55369-4927 KNIGHT 763493-6455 1-800-328-0103 Fax: 763-493-6475 by Honeywell www.farenhyt.com P/N 350280 Rev C, 08/15/06 Copyright © 2006 Silent Knight Wiring lOP-Series Detector Mounting Bases Specifications* Physical Height: 2.0' (5.0 cm) Diameter: 4.1" (10.4 cm) Shipping Weight: 5.2 oz. (147 g) Electrical Operating Voltage: 15-32 VDC Standby Current: 250 pA @ 24 VDC (no communication; LED off) 300 pA @ 24 VDC (one communication every 5 sec with LED enabled) Alarm Current: 6.5 mA © 24 VDC max (with LED on) Environmental Operating Temperature lDP-Photo: 321 - 120°F (0°C - 49°C) lDP-Photo-T: 321 - 100°F (0°C - 38°C) Humidity: 10% - 93% nor-condensing Other Ratings IDP-Photo-T Thermal: Fixed temperature setpoint 135°F (57°C) Velocity: 0 - 4000 fpm (0 - 20 m/sec) lDP-Photo Insect Screen Hole Size: 0.016" (0.41 mm) nominal Ordering Information IDP-Photo Photoelectric Smoke Detector IDP-Photo-T Photoelectric Smoke Detector with Thermal (135°F) Accessoriest SSRA400Z Remote LED Annunciator. SSRMK400 Recessed Mounting Kit. Provides low profile for use with SSB50I. SSXR213 Detector Removal Tool. A removal and replacement tool for IDP plug-in detectors. Includes the SST55-127-000. SSM02-04-01 Detector Test Magnet. SSM02-09-00 Test Magnet with Telescoping Handle. SSXP-4 Extension Pole for SSXR2B. Extends from 5— 15 ft. SST55-127-000 Detector Removal Head. SSBCK-200B Black Detector Kit. For IDP-series detectors. * Unless otherwise noted, specifications apply to lDP-Photo and IDP-Photo-T. t For ordering purposes, an SS has been added to the System Sensor part numbers. Example—System Sensor PN for SSB501 is 13501. SILENT This document is not intended to be used for installation purposes. We try to keep our D KNIGHT product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. S For more information, contact Silent Knight 7550 Meridian Circle Suite 100, Maple by Honeywell Grove, Mn 55369-4927. Phone: (800) 328-0103, Fax: (763) 493-6475. Made in the U.S.A. Addressable Single Action and Dual Action Pull Stations ®MEA 67-02-E Vol. IX ID P-P ull-SA 2FM IDP-Pull-DA Compatibility The IDP-Pull-SA and IDP-Pull-DA are compatible with the following FACPs: IFP-1000 Intelligent Fire Panel IFP-100 Intelligent Fire Panel IFP-50 Intelligent Fire Panel Farenhyt IDP-Pull-SA & IDP-Pull-DA The IDP-Pull-SA is a single action pull station requiring only one motion to activate the station. The lDP-Pull-DA is a dual action pull station requiring two motions to active the station. Both pull stations are designed to work with Silent Knight IFP-series fire alarm control panels (FACP5). Features Installer can open station without causing an alarm condition Dual-color LED is visible through handle of station blinks green to indicate normal operation and remains steady red in an alarm condition Key operated test and reset lock using lock plate actuator Key matches compatible FACP locks Meets the Americans with Disabilities Act Accessibility Guidelines (ADAAG) controls and operating mechanisms guidelines (Section 4.1.3[13]) Meets ADA requirement for 5 lbs maximum pull force to active Shell, door, and handle molded from durable LEXAN® Reliable analog communications for trouble-free operation Braille text on station handle Handle latches in down position and the word Activated appears, clearly indicating the station has been pulled Rotary address switches for fast installation UL Listed, including UL 38, Standard of Manually Actuated Signaling System Installation The IDP-Pull-SA and IDP-Pull-DA can be surface mounted to an SB-I/O surface back box or semi-flush mounted on a standard single-gang with a minimum depth of 2.13(5.40 cm) or double-gang or 4" (10.61 cm) square electrical box. You can also use the optional SSBG-TR (System Sensor® PN BG-TR) trim ring if the station is being semi-flush mounted. 7550 Meridian Circle SILENT Maple Grove, Mn 55369-4927 KNIGHT 763-493-6455 1-800-328-0103 Fax: 763-493-6475 by Honeywell www.farenhyt.com P/N 350286 Rev C, 08/15/06 Copyright ® 2006 Silent Knight Wiring IOP-Pull-SA & lDP-Pull-DA Pull Stations Specifications* Physical Height: 5.5" (14 cm) Width: 4" (10.2 cm) Depth: 5.4 oz. (3.7 cm) Housing Material: LEXAN polycarbonate resin Bi-Colored LED: Blinking Green: Normal Steady Red: Alarm Switch: Single pole, single throw (SPST) normally open (N/O) switch which closes upon activation of the pull station Electrical Operating Voltage: 15-32 VDC Operating Current (LED flashing): 300 pA Wire Gauge: Up to 12AWG (3.1 mm2) Environmental Operating Temperature 320 - 120°F (0°C - 49°C) Humidity: 10% - 93% non-condensing Ordering Information IDP-Pull-SA Single Action Pull Station IDP-Pull-DA Dual Action Pull Station Accessories SSBG-TRt Trim Ring. Optional for pull stations semi- flush mounted SB-I/O Surface Mount Back Box * Unless otherwise noted, specifications apply to IDP-Pull-SA and IDP-Pull-DA. t For ordering purposes, an SS has been added to the System Sensor part numbers. Example—System Sensor PN for 55B501 is 13501. SILENT This document is not intended to be used for installation purposes. We try to keep our KNIGHT D product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 7550 Meridian Circle Suite 100, Maple by Honeywell Grove, Mn 55369-4927. Phone: (800) 328-0103, Fax: (763) 493-6475. Made in the U.S.A. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION 7mi OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0559:140 Page 1 of 1 CATEGORY: Boxes/Pull Stations LISTEE: Silent Knight Security, 7550 Meridian Circle, Maple Grove, MN 55369 Contact: *Michael Mc Isaac (763) 493-6400 FAX (763) 391-5464 DESIGN: Models PS-SA, PS-DA, PS-DASP and IDP-DULL-DA fire alarm pull boxes. *The PS series followed by SA or DA is a single action or dual action pull station that has normally open switch contacts. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. XLF: 7150-0028:199 *Rev. 07-31-2006 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 6, 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering Division COOPER Notification Series RSS and RSSP Strobes and Strobe Plates FIRE I M_T~ A 14d ( Series RSS Series RSS Series RSSWP RSS Round Description The Wheelock patented Series RSS Strobe Appliances and Series RSSP Strobe Plates have lower current draw while maintaining outstanding performance, reliability and cost effectiveness. These versatile appliances will satisfy virtually all requirements for indoor, wall or ceiling mount applications. Strobe options for wall mount models include 1575 or the Wheelock Patented MCW multi-candela strobe with field selectable candela settings of 151301751110cd or the high intensity MCWH strobe with field selectable 135/185cd. Ceiling mount models include the patented MCC multi-candela ceiling strobe with field selectable intensities of 15/30/75/95cd or the high intensity MCCH strobe with field selectable 115/177cd. All models may be synchronized using the Wheelock SM, DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels incorporating the Wheelock Patented Sync Protocol. Synchronized strobes can eliminate possible restrictions on the number of strobes in the field of view. Wheelock's synchronized strobes offer an easy way to comply with ADA recommendations concerning photosensitive epilepsy as well as meeting the requirements of NFPA 72. The Wheelock Series RSS Strobes employ a Patented Integral Strobe Mounting Plate that can be mounted to a single gang, double gang, 4" square, 1 00m European backboxes or the SHBB surface backbox. If the flush backbox has side or top space between it and the finished wall, the NATP (Notification Appliance Trimplate) may be used. It provides an additional .65" of trim for the Appliance. An attractive cover plate is provided for a clean, finished appearance on all models. The Series RSSP Multi-Candela Strobe Plates are a cost effective way to retrofit required wall strobe appliances to bells, horns, chimes, multitones or speakers and easily mounts to standard 4" backboxes or for surface mount use with the Wheelock SBL2 surface backbox. ID M'EA 9 APPROVED S5391 151-92-E 7125-0785:141 7300-0785:154 Features Approvals include: UL Standard 1971, New York City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM), and Chicago (BFP) See approvals by model in Specifications and Ordering Information ADA/NFPNUFC/ANSI compliant. Meets OSHA 29 Part 1910.165 Wall mount Multi-Candela models are available with Field Selectable Candela Settings of 15/30/ 75/110cd or 135/185cd. Single Candela models are available in 1575cd Ceiling mount Multi-Candela models are available with field selectable candela settings of 15/30/75/95cd or 115/177cd. (Round or Square) Strobes produce 1 flash per second over the regulated voltage range 12 and 24 VDC models with wide UL "Regulated Voltage" us- ing filtered (DC) or unfiltered VRMS input voltage Synchronize using the Wheelock sync modules or panels with built-in Wheelock Patented Sync Protocol Fast installation with IN/OUT screw terminals using #12 to #18 AWG wire For Weatherproof Series RSS See Datatsheet S9004 NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERWHEELOCK.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR *OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range". Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 t 3 flashes per second. All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. Series NS Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% (± 2%). Series NH horns are listed under UL Standard 464 for audible signal appliances (Indoor use only). "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change UL used the terminology "Listed Voltage Range". Table 1: Average RMS Current* RSS/RSSP - Wall Mount Ceiling Mount RSS/RSSP 241575W 24MCW 24MCWH 24MCC 24MCCH 24VDC Models I I I I I I I 1575cd 15cd I 30cd I 75cd j 110cd 135cd I 185cd 15cd I 30cd I 75cd I 95cd 11 5c 177cd UL max* 0.090 0.060 0.092 0.165 0.220 0.300 0.420 0.065 0.105 0.189 0.249 0.300 0.420 RSS/RSSP RSS/RSSP Wall Mount 24VDC * RMS current ratings are per UL average RMS method. UL max current _______ Models 121 575W rating is the maximum RMS current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum 12 vdc 0.152 listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, UL max* 0.255 see Installation instructions. Table 2: Audibles/Speakers for RSSP Strobe Plate Product Series Multitone Appliances AMT, MT Horns AH, NH, HS Motor Bells MB-G6/G10 Speakers ET-1010/1080, E70, ET70 Chimes CH70 Wiring Diagrams RSS/RSSP APPLIANCE FROM TO NEXT PRECEDING APPLIANCE APPLIANCE, SYNC OR EOLR MODULE, POWER SUPPLY OR FACP SERIES RSS/RSSP APPLIANCES SYNCHRONIZED WITH DSM MODULE SINGLE CLASS "A" NAC CIRCUIT DSM STROBE 0 NAC SYNC - 0 CIRCUIT OUT 0 -OUT 1 O"IN1 RSS RSS RSS 0 MINUS 1 0+ ]ROBE AUDIBLE o MINUS 2 IN 2 RSS IRS. NAC O"OUT 2 CIRCUIT RETURN SERIES RSS/RSSP APPLIANCES SYNCHRONIZED WITH MULTIPLE DSM MODULES DSM #1 DSM Interconnecting wiring shown. Maximum of twenty (20) SERIES RSS/RSSP APPLIANCE SYNCHRONIZED WITH SM MODULE SINGLE CLASS "B" NAC CIRCUIT SM F + STROBE 0 - STROBE Strobe A NAC Circuit C 0— Audible P X >EOLR Audible SERIES RSS/RSSP APPLIANCES SYNCHRONIZED WITH PS-12/24-8CP or P8-12/24-8MP Series PS-12/24-8MP OUTPUTS 1-4 IItE:EII:RSS :Ij EOLR F - 4-CLASS A 'B' OR AS RSS C 2-CLASS A P AS RSS Series PS-12124-8MP TROBE/PLATE ASSEMBLY UDIBLE & VISIBLE APPLIANCE OPERATE IN UNISON TO NEXT FROM _____ ______________ + APPLIANCE PRECEDING II i II i - OR EOLR APPLIANCE, SYNC MODULE, POWER SUPPLY ORFACP + - STROBE AUDIBLE STROBE/PLATE ASSEMBLY AUDIBLE & VISIBLE APPLIANCE OPERATE INDEPENDENTLY FROM + PRECEDING + TO NEXT APPLIANCE OR - APPLIANCE FACP - OR EOLR FROM + TONEXT PRECEDING STROBE OR STROBE, SYNC - - - Ti 1 1 EOLR - — MODULE, POWER SUPPLY ORFACP + STROBE APPLIANCE For detail using SM or DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. For wiring information on the power supplies refer PS-24-8MC. Specifications and Ordering Information Model Order Code Wall Mount Ceiling Mount Non- Sync Strobe Candela 24 VDC 12 VDC Color RED Color WHITE Mounting Options Square or Round Agency Approvals UL MEA CSFM FM BFP RSS-24MCW-FR 940 )( - X 15/30/75/110 X - X - B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS-24MCW-FW 9401 X - X 15/30/75/110 X - - X B,D,EF,G,H,J,N,O,R,X Square X X X X X RSS-241575W-FR 7471 X - X 15(75onAxis) X - X - B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS-241575W-FW 7788 X - X 15(750n Axis) X - - X B,DE,F,G,H,J,N,O,R,X Square X X X X X RSS-121575W-FR 7476 X - X 15(75on Axis) - X X - B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS-121575W-FW 7468 X - X 15(75on Axis) - X - X B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS-24MCC-FW 3158 - X X 15/30/75/95 X - - X B,D,E,F,G,H,J,N,O,R,X Square X X X X * RSS-24MCC-FR 3157 - X X 15/30/75/95 X - X - B,D,E,F,G,H,J,N,O,R,X Square X X X X * RSS-24MCCR-FW 3160 - X X 15/30/75/95 X - - X B,D,E,F,G,H,J,N,O,R,X Round X X X X * RSS-24MCCH-FW 3461 - X X 115/177 X - - X B,D,E,F,G,H,J,N,O,R,X Square X X X X * RSS-24MCCHR-FW 3463 - X X 115/177 X - - X B,D,E,F,G,H,J,N,O,R)( Round X X X X * RSS-24MCWH-FR 3465 X X 135/185 X X B,D,E,F,G,H,JN,O,R,X Square X X X X * RSS-24MCWH-FW 3464 X X 135/185 X X B,D,E,F,G,H,J,N,O,R,X Square X X X X * RSSWP2475WFR** 9013 X - X 180@ 77-F X X X - B,D,E,F,G,H,J,N,O,R,X Square X X X X * RSSWP2475WFW** 3034 X - X 180@ 77-F X X - X B,D,E,F,G,H,J,N,O,R,X Square X X X X * RSSP-121575W-FR 7798 X - X 15(75onAxis) - X X - D,E,Z Square X X X X X RSSP-24MCW-FR 9402 X - X 15/30/75/110 X - X - D,E,Z Square X X X X X RSSP-241575W-FR 7793 X - X 15(75onAxis) - - X - D,E,Z I Square xj X X X X *PENDING All models sync with Wheelock SM, DSM or PS-12/24-8CP or PS-12/24-8MP. # Models are available in either Red or White. Call Customer Service for Order Code & Delivery. **For Weatherproof Series RSS Strobe specifications see data sheet S9004. ***Refer to data sheet S7000 for mounting options. S0410 RSS/RSSP 02/08 Arcnhrecis ana The visual notification appliances shall be Wheelock Series RSS Strobe Appliances or approved equals. The Series RSS shall meet and be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The strobe shall be listed for indoor use and shall meet the requirements of FCC Part 15 Class B. The strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). When Strobe Plates are to be installed, they shall be the Wheelock Series RSSP Strobe Plate and shall have the same electronic circuitry as the Wheelock Series RSS. The Series RSS Strobe shall be of low current design. Where Multi-Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 at 15/30/75/110cd or 135/185cd for wall mount and 15/30/75/95cd or 115/177cd for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatible with Wheelock's SM, DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels with built-in Wheelock Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non-synchronized flash rate. The strobes shall be designed for indoor surface of flush mounting. The Series RSS Strobe Appliances shall incorporate a Patented, Integral Strobe Mounting Plate that shall allow mounting to single- gang, double-gang, 4-inch square, 1 00m European type backboxes, or the SHBB Surface Backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided. An attaching cover plate shall be provided to give the Appliance and attractive appearance. The Appliance shall not have any mounting holes or screw heads visible when the installation is completed. The Series RSSP Multi-Candela or single candela Strobe Plate shall mount to either a standard 4 inch square backbox for flush mounting, or the Wheelock SBL2 backbox for surface mounting. All notification appliances shall be backward compatible. NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock, Inc. standard terms and conditions. iEAt4 WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Made in USA Cooper Notification is Wheelock* IC) SAFEPATH WAV) COOPER Notification CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM IL LISTING SERVICE LISTING No. 7125-0785:141 Page 1 of I CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: Wheelock Inc., 273 Branchport Ave., Long Branch NJ 07740 Contact: Deborah Piserchia (732) 433-6001 Fax (732) 222-5607 DESIGN: Synchronized or non-synchronized Strobe Lights. Models are as follows: RSS-##W RSSP-##W RSS-##C RSSP-##C RSS-##CR RSSP-##CR 2415 2415 2415 2415 2415 2415 2475 2475 2430 2430 2430 2430 241575 241575 2475 2475 2475 2475 2430 2430 *2495 *2495 *2495 *2495 24110 24110 1215 1215 121575 121575 Also, Models RSS-24MCW and RSSP-24MCW, RSS-24MCC, RSS-24MCCR, RSSP- 24MCC, RSS-24MCWH, RSS-24MCWHR, RSSP-24MCWH, RSS-24MCCH, RSS- 24MCCHR, RSSP-24MCCH, *ZRS..MCC *ZRSMCW *ZRS.MCCH and *ZRS..MCWH Model numbers may be followed by any two alpha/numeric character indicating lens orientation, lettering and color. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical 12 = 8-17.5VDC/FWR OR 24 = 16-33VDC/FWR Candela 155cd, 157515/75cd on axis, 3030cd, 75=75cd, 110=110cd (Wall) RSS-24MCW, RSSP-24MCW, *ZRS..MCW: Selectable 15cd, 30cd, 75cd orll0cd RSS-24MCC, RSS-24MCCR, RSSP-24MCC, *ZRS MCC: Selectable 15cd, 30cd, 75cd and 95cd RSS-24MCWH, RSS-24MCWH R, RSSP-24MCWH, *ZRSMCWH: Selectable 135cd, 185cd RSS-24MCCH, RSS-24MCCH R, RSSP-24MCCH, *zRS..MCCH: Selectable 115cd, 177cd Flash rate 60 flashes/minute INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Models with suffix -W, wall mount only. Models with suffix -C, ceiling mount only. All models are for indoor use only. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as strobe light suitable for the hearing impaired when used with separately listed electrically compatible fire alarm control units. For synchronization strobes, Models SM- 12/24, SMX-12/24, DSM-12/24 or DSMX-12/24 Sync Control Module (CSFM Listing No. 7300-0785:132) must be used. Refer to listee's Installation Instruction Manual for details. *Rev. 12-13-2006jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 30, 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering Division Series AS Audible Strobe Appliances and Series AH Audibles ISERIESVAS 1 SERIES AH Description The Wheelock patented 2-wire Series AS Audible Strobe Appliances and Series AH Audibles offer more features with low current draw. Strobe options for wall mount models include 1575cd or the Wheelock patented MCW multi-candela wall strobes with field selectable candela settings of 15/30/75/110cd, or the high intensity MCWH strobe with field selectable 135/185cd. Ceiling mount models incorporate Wheelock's patented MCC multi-candela ceiling strobe with field selectable intensities of 15130175195cd or the high intensity MCCH strobe with field selectable 115/177cd. The audible provides a selectable choice of either a continuous horn or temporal pattern (Code 3) when constant voltage from a Fire Alarm Panel (FACP) is applied. Each tone has 3 dBA settings to choose from. When used with the Wheelock Series SM,DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels incorporating the Wheelock Patented Sync Protocol, synchronization of the continuous horn tone provides the temporal (code 3) tone (mandated by N FPA 72) simultaneously for all audible appliances. This ensures a distinct temporal (code 3) pattern when 2 or more audibles are within hearing distance. If not synchronized the temporal sound could overlap and not be distinctive. At the same time the strobes will be synchronized. This provides the ability to comply with ADA guidelines concerning photosensitive epilepsy and the NFPA standards when installing 2 or more visual appliances within the field of view all of this plus the ability to silence the audible is achieved by using only 2 wire. Features Approvals include: UL Standard 1971, UL Standard 464 New York City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM), and Chicago (BFP). See approvals by model in Specifications and Ordering Information ADA/NFPAIUFC/ANSI Compliant Wall mount models are available with Field Selectable Candela Settings of 15/30175/110cd or 135/185cd (Multi- Candela models) or 1575cd (single candela model) Ceiling mount models are available with field selectable candela settings of 15/30/75195cd or 115/177cd (multi-candela ceiling models) Selectable Continuous Horn or Temporal (Code 3). 3 Selectable dBA settings (99, 95 and 90 dBA) in both tones Patented 2-Wire Audible Strobe Appliance. Patented Universal Mounting Plate Weatherproof models are available for outdoor use Strobes produce I flash per second over the regulated voltage range 12 and 24 VDC models with wide UL "Regulated Voltage Range" using filtered DC or unfiltered FWR input voltage Synchronize using the Wheelock Sync Modules or panels with built-in Wheelock Patented Sync Protocol Fast installation with IN/OUT screw terminals using #12 to #18 AWG wires For Weatherproof Series AS, See Datasheet S9004 (D 0 <*> MEA APPROVED E5946 151-92-E 7125-0785:131 S5391 High (99) vdc 0.163 0.260 H1 L2dBA ax* 0.192 0.320 Med (95) 12 vdc 0.076 0.195 UL max* 0.108 0.275 dBA Low (90) 12 vdc 0.039 0.175 UL max* 0.058 0.265 dBA 24 VDC Models High (99) 24 vdc dBA ULmax* Med (95) 24 vdc dBA UL max* Low (90) 24 vdc dBA UL max* 12 VDC Models AH-24 AS-241575W AS-24MCW AS-24MCWH AS-24MCC AS-24MCCH 1575cd 15cd 30cd 75cd 110cd 135cd 185cd 15cd 30cd 75cd 95cd 11 5c 177cd 0.062 0.100 0.080 0.102 0.150 0.194 0.250 0.320 0.088 0.114 0.165 0.205 0.250 0.320 0.080 0.121 0.088 0.125 0.200 0.267 0.355 0.480 0.095 0.138 0.221 0.285 0.355 0.480 0.033 0.080 0.060 0.084 0.132 0.173 0.230 0.305 0.066 0.092 0.145 0.186 0.230 0.305 0.043 0.107 0.074 0.110 0.190 0.253 0.340 0.465 0.080 0.122 0.201 0.269 0.340 0.465 0.017 0.072 0.052 0.076 0.121 0.158 0.220 0.295 0.056 0.082 0.132 0.173 0.220 0.295 0.021 0.100 0.068 0.105 0.182 0.245 0.335 0.460 0.074 0.113 0.198 0.263 0.335 0.460 Audible Wall Mount Audible Strobe AH-12 I AS-121575W Table 4: Average Current* (AMPS) For Series ASWP' Voltage High dBA Setting (99)dBA Medium dBA Setting (95)dBA Low dBA Setting (90)dBA 0 VDC 0.128 0.105 0.098 24 ffUL Max* 0.168 0.155 0.150 * RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERWHEELOCK.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range". Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 t 3 flashes per second. All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. Series NS Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% (± 2%). Series NH horns are listed under UL Standard 464 for audible signal appliances (Indoor use only). Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change UL used the terminology "Listed Voltage Range". Table 1: Ratings Per UL 1971 Model Number Input Voltage VDC Regulated Voltage Range VDCIFWR Strobe Candela (Cd) AS-24MCW 24 16.0-33.0 15/30/75/110 AS-24MCCH 24 16.0-33.0 115/177 AS-241575W 24 16.0 -33.0 15 (75 on Axis) AS-121575W 12 8.0-17.5 15 (75 on Axis) AS-24MCC 24 16.0-33.0 15/30/75/95 AS-24MCWH 24 16.0-33.0 135/185 ASWP-2475W 24 16.0 -33.0 75 @ -31°F Table 2: dBA Ratings for 12 VDC and 24 VDC Series AS/ AH 12 and 24 VDC Audible Reverberant Anechoic Description Volume dBA dBA Per UL 464 @10 ft. @10 ft. High 91 99 Continuous Medium 88 95 Horn Low 83 90 High 87 99 Code 3 Horn Medium 84 95 Low 79 90 Table 3: Average RMS Current I Audible Wall Mount Audible Strobe Models Ceiling Mount Audible Strobe Models Wring Diagrams* SERIES AS APPLIANCES NON-SYNCHRONIZED FROI +0TO NEXTE PRECEDINGD OR EOLRD OR FACPL] APPLIANCEE —PPLIANCEL] SERIES AS & RSS APPLIANCES SYNCHRONIZED NTH PS-12124-8CP and PS-12/24-8MP OUTPUTS 5-45 EOLSS IJTSD - 4-CLASSO AD 050 ASO Rssn cLI "Am ASO Series PS-12/24-8 PD SERIES AS APPLIANCES SYNCHRONIZED WITH DSM MODULE CLASS"A" NAC CIRCUIT WITH NO AUDIBLE SILENCE FEATURE Specifications and Ordering Information DSM Interconnecting wiring shown. Maximum twenty (20)0 44For detail using SM or DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. For wiring informationon the power supplies refer to Installation Instructions P84662 for PS-24-8MC. SERIES AS APPLIANCES SYNCHRONIZED WITH SM MODULE SIN- GLE CLASS "B" NAC CIRCUIT WITH AUDIBLESILENCE FEATURE FE] 10 Strobe D +STROBSO DSTROSSD I\.LI NACO Circuit AS C 11 dii cC P cOLAS AudibleD udub cC NACO CircuitO SERIES AS APPLIANCES SYNCHRONIZED WITH MULTIPLE DSM MODULES -SM #10 Strobe NAC Cir/"fl 0 -' b FLI Audible NAC AD Strobe NAC 00 co !Audible NAC -h-1ASM 30 PD - i I ffL Strobe NAC C Model Number Order Code Strobe Candela Non- Sync Syncw!SM, DSM or PS-24-8MC 24 VDC 12 VDC Wall Mount Ceiling Mount Mounting Options*** Agency Approvals \S-24MCW-FR 9024 15/30/75/110 X X X - X - A,B,D,E,F,G,H,JNOR,X X X X X X \S-24MCW-FW 9025 15/30/75/110 X X X - X - A,B,D,E,F,G,HJ,N,O,R,X X X X X X \S-24MCWH-FR 3468 135/185 X X X - X - A,B,D,E,F,GHJN,O,R,X X X I X X * \S-24MCWH-FW 3469 135/185 X X X - X - A,B,D,E,F,GH,J,N,O,R,X X X X X * \S-241575W-FR 7405 15(75onAxis) X X X - X - A,B,D,E,F,GH,J,N,O,R,X X X X X X \S-121575W-FR 7410 15(75onAxis) X X - X X - A,B,D,EFGH,J,N,O,R,X X X X X X \S-24MCC-FR 3161 15/30/75/95 X X X - - X A,B,DEF,G,H,J,N,O,R,X X X X X * \S-24MCC-FW 3162 15/30/75/95 X X X - - X A,BDE,F,G,H,J,N,O,R,X X X X X * \S-24MCCH-FW 3467 115/177 X X X - - X ABDE,F,GH,J,N,O,R,X X X X X * \SWP2475WFR** 9012 75 @ -31°F X X X - X - I(see Data Sheet S9004) X X X X X \H-24-R 7892 - X X X - X X A,B,D,E,F,G,H,J,N,OR,X X X X X X \H-24-W 7893 - X X X - X X A,B,DEF,GH,J,N,OR,X X X X X X \H-1 2-R 7891 - X X - X X X A,B,DE,F,G,H,J,N,O,R,X X X X X X H-1 2-W 7894 - X X - X X X A,B,D,EF,G,H,J,N,OR,X X X X X X \H24WPR** 7416 - X X X - X X K X X X X \H12WPR** 7415 - X X - X X X K X X X X **For Weatherproof Series AS/AH specifications see data sheet S9004. *PENDING ***Refer to Data Sheet S7000 for Mounting Options. Note: Models are available in either Red or White. Contact Customer Service for Order Code and Delivery. NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc. standard terms and conditions. S8100 AS/AH 10107 Architects and Engineers Specifications The notification appliances shall be Wheelock Series AS Audible Strobe appliances and Series AH Audible appliances or approved equals. The Series AS Audible be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The Series AH Audible shall be UL Listed under Standard 464 (Fire Protective Signaling). Both shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). The audible portion of the appliance shall have a minimum of three (3) field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3) audible outputs. The strobe portion of the appliance shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The Series AS shall be of low current design. Where Multi- Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 at 15/30/75/110 or 135/185 candela for wall mount and 15/30/75/95 or 115/177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatible with Wheelock's SM, DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels with built-in Wheelock Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non-synchronized flash-rate. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock synchronization. The Series AS Audible Strobe and Series AH Audible shall incorporate a Patented Universal Mounting Plate that shall allow mounting to a single-gang, double-gang, 4-inch square, 1 00m European type backboxes, or the SHBB Surface Backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided. All notification appliances shall be backward compatible. !A1Id I Y Mon,ber WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Made in USA Cooper Notification is Wheelock ICJ SAFEPATH WAV) #0 COOPER Notification 00 COOPER Wheelock Weatherproof Appliances - Series AH Audibles, AS Audible Strobes, MT Multitone Strobes, RSS Strobes and ET70 Speaker Strobes and Weatherproof Mounting Accessories Description: Designed for life safety, performance and reliability, Cooper Wheelock's cost effective weatherpoof notification appliances include: Weatherproof Appliances Series Strobes RSSWP Horn Strobes ASWP Horns AH-24WP, AH-12WP Multitone Horn Strobes MTWP Multitone Horns MT Speaker Strobes ET70WP Speakers El-lOb All strobe models are UL dual listed - meeting both UL1638 and UL1971 requirements. As dual listed appliances, these weatherproof strobes, horn strobes and speaker strobes are listed for outdoor applications under UL 1638 as well as under UL 1971, the Standard for Safety Signaling Devices for Hearing Impaired. With an extended temperature range of —31°F to 150°F (-40°C to 660C), Wheelock weatherproof appliances meet or exceed UL outdoortest requirements for rain, humidity and corrosion resistance while providing multiple strobe intensity options, including the highest strobe ratings available for area coverage per NFPA 72 strobe spacing tables (up to 185 candela for wall mounting and 177 candela for ceiling mounting). To enable weatherproof mounting, Cooper-Wheelock provides the industry's widest choice of mounting options for surface or unique semi-flush installation. Models are available for surface mounting to Wheelock weatherproof backboxes on walls or ceilings. The optional WP-KIT allows the weatherproof backboxes (lOB, WPBB or WPSBB) to be mounted to a recessed electrical box for concealed conduit installation. For semi-flush installation, the WPA and WFPA kits allow a customer to mount the weatherproof appliances to a recessed electrical box without the need for an external weatherproof backbox. See the Backboxes, Plates and Gaskets Table on page three of this document for a summarization of these mounting options and the required accessories. ©MFEA '\ APPROVED E5946 151-92-E 7125-0785:131 (ASWP) S5391 7125-0785:146 (ET70WP) S2652 7125-0785:156 (MTWP) 7300-0785:154 (RSSWP) When used in conjunction with Wheelock PS-24-8MC Power Supplies or SM/DSM Sync Modules, the Wheelock weatherproof appliances can be synchronized to meet NFPA 72 synchronization requirements. The horn output of horn strobes can be independently controlled on 2-wire circuits using the Wheelock patented sync protocol. MTWP horn strobe models are 4-wire appliances; the strobes can be synchronized while the audible can be connected to a coded fire alarm system or can be set to produce any of eight selectable tones. Features: Approvals include: UL Standards 1971, 1638, 464 and 1480 California State Fire Marshal (CSFM) and New York City (MEA), Factory Mutual (FM) and Chicago (BFP). See agency approvals by model number on page two of this document Compliance with the following requirements: NFPA, UFC, ANSI 117. 1, OSHA Part 29, 1910.165, ADA Weatherproof with extended temperature range of —40°F to 150°F (-40°C to 66C)* Dual Listed strobe models (UL 1638 and UL 1971) Industry's highest strobe candela options Synchronization capability using Series SM, DSM Synch Modules (MTWP and MT-12/24 audible is non-sync) Models with field selectable tone, dBA and candela settings Wall or ceiling mounting options Surface of semi-flush mounting IN/OUT wiring termination accepting two #12-18 AWG wires at each terminal *The series RSSWP, ASWP, MTWP and ET70VVP have UL approval down to -40°F The AH-24W MT-1 2/24 and the ET-1 010 have been ULC tested and approved to -40°F, but not submitted to UL The AH-12WP has UUULC approval to -31°F. Strobe Order Code RSSWP-2475W-FR Red 9013 RSSWP-2475W-FW White 3034 .RSSWP-24MCWH-FR Red 5161 RSSWP-24MCWH-FW White 5165 Audible Strobe ASWP-2475W-FR Red 9012 ASWP-24MCHW-FR Red 5137 ASWP-24MCWH-FW White 5140 8420 Multi-tone Strobe 3112 MTWP-2475C-FR Red 4457 5132 MTWP-2475C-FW White 4478 5134 MTWP-24MCCH-FR Red 5102 MTWP-24MCCH-RN White 5122 9077 Speaker Strobe 3179 ET70WP-2475C-FR Red 4452 4885 ET70WP-2475C-FW White 4454 4891 ET70WP-24177C-FR Red 4845 ET70WP-24177C-FW White 4859 Multi-tone Strobe MTWP-2475W-FR Red MTWP-2475W-FW White MTWP-24MCWH-FR Red MTWP-24MCWH-FW White Speaker Strobe ET70WP-2475W-FR Red ET70WP-2475W-RN White ET70WP-24185W-FR Red ET70WP-24185W-FW White Strobe Order Code RSSWP-2475C-FR Red 4338 RSSWP-2475C-FW White 4446 RSSWP-24MCCH-FR Red 5167 RSSWP-24MCCH-FWWhite 5187 Audible Strobe ASWP-2475C-FR Red 4251 ASWP-2475C-FW White 4502 ASWP-24MCCH-FR Red 5149 ASWP-24MCCH-FW White 5157 Audible Order Code AH-24WP-R Red 7416 AH-i 2WP-R Red 7415 Horn MT-1 2/24-R Red 5023 Speaker ET-1010-R Red 3135 ET-1010-W White 3137 UL Max. Current AH 24 VDC 12 VDC High (99) dBA 0.080 0.192 Med (95) dBA 0.043 0.108 Low (90) dBA 0.021 0.058 U L Reverberant dBA @ 10 Feet Wafts 1/8 1/4 1/2 1 2 4 8 ET-1010 77 80 83 86 87192 194 ET70WP 78 81 184 187 90193 195 Model Number Agency Approvals Strobe UL MEA CSFM FM BFP RSSWP-2475 X X X X * RSSWP-24MCWH X * * * * RSSWP-24MCCH X * * * * Audible Strobe ASWP-2475 X X X X X ASWP-MCWH X * * ASWP-MCCH X * * * * Multitone Strobe MTWP-2475 X X X X * MTWP-MCWH X * * * * MTWP-MCCH X * * * * Horns/Audibles AH-24WP X X X - X AH-12WP X X X - X MT-12/24 X X X X X Speaker Strobe ET70WP-2475 X X X * * ET70WP-1 85 X * * * * ET70WP-177 X * * * * *pending NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERWHEELOCK.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: Strobes are designed to flash at 1 flash per second minimum over their UL Listed Regulated Voltage Range. All candela ratings represent minimum effective Strobe intensity based on UL Standards 1971 and 1638 as indicated in candela ratings table. Wall Mount Ceiling Mount RSSWP MTWP RSSWP MTWP PIRE ASWP EI1OWP ASWP ET70WP Wall or Ceiling Mount a AH Candela Ratings Series UL 1971 @320 120°F UL 1638 © 77°F UL 1638 @-40°F RSS, ET7OWP and MTWP UL Max Current (Strobe Only) ASWP High Med Low 2475 30 180 115 0.138 0.168 0.155 0.150 MCWH 135 135 65 0.300 0.355 0.340 0.335 185 185 90 1 0.420 0.480 0.465 0.460 MCCH 115 115 50 0.300 0.355 0.340 0.335 177 177 75 0.420 0.480 0.465 0.460 24185 185 185 90 0.420 24177 177 177 75 0.420 JL Max. Current Audible) MTWP/MT 24 VDC MT 12 VDC IBA HI STD HI STD Horn 0.108 0.044 0.177 0.034 3e11 0.053 0.024 0.095 0.020 March Time 0.104 0.038 0.142 0.034 0de 3 Horn 0.091 0.035 0.142 0.034 ode3Tone 0.075 0.035 0.105 0.021 low Whoop 0.098 0.037 0.142 0.035 iren 0.104 0.036 0.152 0.030 li/Lo 0.057 0.025 0.114 0.026 Mounting Accessories __ WFP WFPA Gasket Kit Order Code WP-KIT 4486 Flush Plates WFPA-R Red 4698 WFPA-W White 4701 WFP-R Red 4696 WFP-W White 4697 Backboxes lOB-R Red 5046 lOB-W White 5047 WPSBB-R Red 9751 WPSBB-W White 3033 WPBB-R Red 9014 WPBB-W White 4692 WBB-R Red 2959 WBB-W White 2960 lOB WPSBB WPBB WBB Mounting Options: Backboxes, Plates, Gasket Kits Surface Mount Flush Mount Exposed Conduit Concealed Conduit RSSWP Strobes WPSBB WPSBB + WP-KIT WFP ET70WP Speaker Strobes lOB lOB + WP-KIT WFP ASWP Horn Strobes WPBB WPBB + WP-KIT WFPA AHWP Horns WBB - WFP ET-1010 Speakers WBB - WFP MTWP Multitone Horn Strobes lOB lOB + WP-KIT WFP Multitone Horn lOB lOB + WP-KIT WFP Wiring Diagrams IL)IVI + TO NEXT RECEDING + RED APPLIANCE PPLIANCE - ___ R FACP BLACK - OR EOLR STROBE AUDIBLE SERIES RSSWP, ASWP, AHWP, MTWP AND MT-12/24 APPLIANCES FROM ____ ________ TO NEXT PRECEDING + + I --u - APPLIANCE APPLIANCE OR OR EOLR FACP SERIES MTWP APPLIANCES SYNCHRONIZED STROBE OPERATION WITH CODED FACP MTWP o Strobe 0 0 Sync0 ircuft Module NAC#10 or I 0 5-124-8 Audible Power Circuit FACP supply NAC#2 Note: Strobe circuit requires constant voltage. SERIES RSSWP/ASWP APPLIANCES SYNCHRONIZED WI DSM MODULE SINGLE CLASS "A" NAC CIRCUIT DSM STROBES NACS SYNC 0 CIRCUIT OUTO p+OUT 18 O+IN1@ RSSE • MINUS 18 AUD lB LEN 28 ØMINUS + IN 28 ROBE NACIR 0 + 01JT28 CIRCUITS RETURNIN SERIES MTWP AUDIBLE APPLIANCE AND STROBE OPERATE IN UNISON. RED AND BLACK SHUNT-WIRES ARE SUPPLIED. Note: Models are available in Red or White. Contact Customer Service for Order Code and Delivery. #Refer to Data Sheet S7000 for Mounting Options NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc. standard terms and conditions. ARCHITECTS AND ENGINEERS SPECIFICATIONS General Weatherproof notification appliances shall be UL listed for outdoor use. Weatherproof Strobe appliances shall be listed under UL Standard 1638 (Standard for Visual Signaling Appliances) for Indoor/Outdoor use and UL Standard 1971 (Standard for Safety Signaling Devices for Hearing Impaired). The appliances shall be available for optional wall mounting or ceiling mounting to weatherproof backboxes using either exposed conduit or concealed conduit, or semi-flush mounting to a recessed electrical box in walls or ceilings using Wheelock mounting accessories. Weatherproof Strobes Weatherproof Strobe appliances shall produce a minimum flash rate of 60 flashes per minute over the UL Regulated Voltage Range of 16 to 33 VDC and shall incorporate a Xenon flashtube. The weatherproof strobes shall be available with UL 1971 candela ratings up to 185 cd for wall mounting and 177 cd for ceiling mounting. UL 1638 candela ratings up to 180 cd at 77°F shall be available. The strobes shall operate over an extended temperature range of —40°F to 150°F (-40°C to 66°C) and be listed for maximum humidity of 95% RH. Strobe inputs shall be polarized for compatibility with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). Weatherproof Audibles and Audible/Strobe Combinations Weatherproof horns and multitone audibles shall be listed for Indoor/Outdoor use under UL Standard 464. The horns shall be able to produce a continuous output or a temporal code-3 output that can be synchronized. T Multitone audibles shall be able to produce 8 distinct tones selectable by dip switch and shall have at least 2 sound level settings. Multitone Audible/Strobe combinations shall have independent inputs for the audible and strobe. The strobes shall be able to be synchronized. The audibles shall be able to be coded when operated on a separate NAC. Weatherproof Speakers and Speaker/Strobes Weatherproof speakers and speaker/strobes shall be listed for Indoor/Outdoor use under UL Standard 1480. All speakers shall provide field selectable taps for 1/8W to 8W operation for either 25 VRMS or 70 VRMS audio systems and shall incorporate a sealed back construction for extra protection and improved audibility. Speakers without strobes shall be Wheelock Series ET-1 010. They shall be listed to produce up to 94 dBA and shall incorporate a vandal resistant grille design. Speaker with strobes shall be Wheelock Series ET70WP. They shall be available for surface or semi-flush mounting to walls or ceilings and shall be listed to produce up to 93 dBA. Synchronization Modules When synchronization of strobes or temporal code-3 audibles is required, the appliances shall be compatible with the Wheelock Series SM and DSM Sync Modules or the Wheelock PS-24-8MC Power Supply with built-in, patented sync protocol. The strobes and audibles shall not drift out of synchronization at any time during operation. Series ASWP audibles and strobes shall be able to be synchronized on a 2-wire circuit with the ability to silence the audible if required. The strobes on Series MT multitone audible/strobe appliances shall be able to be synchronized and shall be able to be operated on a separate circuit from the audibles while the audible circuit is connected to a coded or continuous NAC. Weatherproof Mounting Accessories Weatherproof mounting options shall include surface mounting or semi-flush mounting to walls or ceilings. Surface mounted appliances shall mount to Wheelock lOB, WBB, WPBB or WPSBB weatherproof backboxes using either exposed conduit or concealed conduit. For concealed conduit the weatherproof backbox shall be mounted to a recessed electrical box with Wheelock's WP-KIT to provide a weatherproof seal for the electrical box. Semi-flush mounted appliances shall mount to a recessed electrical box using Wheelock WFP or WFPA flush plates to provide a weatherproof seal between the electrical box and the appliance. 273 Branchport Avenue Long Branch, NJ 07740 Phone: (800) 631-2148 Fax: (732) 222-2588 www.cooperwheelock.com Member WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Made in USA S9004 WP 03/07 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTiNG PROGRAM LISTING SERVICE LISTING No. 7125-0785:131 Page 1 of 2 CATEGORY: Fire Alarm Devices for the Hearing-Impaired LISTEE: Wheelock Inc., 273 Branchport Ave., Long Branch NJ 07740 Contact: Deborah Piserchia (732) 433-6001 Fax (732) 222-5607 DESIGN: Models AS-1215, -2415, -1230, -2430, -121575, -241575, -2475 and -24110 audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. Models AS-1215W, -2415W, -1230W, -2430W, -121575W, -241575W, -2475W and -24110W audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. These units with suffix -W are for wall mount only. *Models AS-121575W and AS-241575W lens color may be white, red, blue, green, or amber. Models AS-2415C, -2430C, -2475C and -24100C audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering, orientation and color. These units are intended for ceiling mount only. Model AH-12, -24, AH-I2WP, -24WP audible appliances (no strobe), followed by an alpha or numeric character indicating product color. Model AS-24MCW and AS-24MCC audible/strobe, followed by any two alpha or numeric character indicating lettering and product color. *Lens color may be white, red, blue, green, or amber. Models ASWP-2475W and *Aswp..2475C audible/strobe with integral private mode fire/emergency visual signaling for non-hearing impaired applications. Lens color may be white, red, blue, green, and amber. Both models are suitable for outdoor use when mounted on the Model WPBB back box. Models AS-24MCWH, AS-24MCCH, *ASWP24MCWH and *ASWP.24MCCH audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering and product color. Units with suffix CH are for ceiling mount only. Units with suffix WH are for wall mount only. *Lens color may be white, red, blue, green, or amber. Refer to the listee's data sheet for detailed product description and operational considerations. RATING: Electrical: 8-17.5/16-33 VDCNFWR Flash Rate: 60 flashes/minute Candela: 15:15cd, 1575:15/75cd, 30:30cd, 75:75cd, 95:95cd, 100:100cd, 110:110cd MCW: Selectable 15cd, 30cd, 75cd, 110cd MCC: Selectable lscd, 30cd, 75cd, 95cd MCWH: Selectable 135cd, 185cd (65cd, 90cd at-40 C) MCCH: Selectable 115cd, 177cd (50cd, 75cd at -40 C) Listing No. 7125-0785:131 Page 2 of 2 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Models ASWP-2475W, ASWP- 24MCWH, AS-24MCW and AS-24MCWH are for wall mount only. Models ASWP-24750, ASWP-24MCCH, AS-24MCCH, AND AS-24MCC are for ceiling mount only. Models with suffix - W or WH are for wall mount only. Models with suffix -c or -CH are for ceiling mount only. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as audible and audible/visual signaling devices suitable for the hearing impaired when used in conjunction with separately listed electrically compatible fire alarm control units. For indoor use only except Models AH-12WP, AH-24WP, *Aswp2475w ASWP-2475C, ASWP-24MCWH, and ASWP-24MCCH audible appliances are suitable for indoor/outdoor. For synchronization, Models AS Series must be used with Model SM-12/24, SMX-12/24, DSM-12/24 or DSMX-12/24 sync control module (CSFM Listing No. 7300-0785:132). Refer to listee's Installation Instruction Manual for details. These appliances can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. NOTE: Models AH-12, AH-24, -12WP and -24WP audible devices are not suitable for the hearing impaired applications. *Rev. 10-01-07 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verity correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 26, 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering Division nn -)Koneywell.com 4ACS -3Socurity 'j W MW 4@ peg FIT 7. 4 —JLWA1 ARTICLE 760 Fire Alarm Systems Riser Cables Unshielded Applications: Wiring of Fire protective signalling circuits. Code Restrictions: OK for use with all power limited circuits except those in plenums. Features: Available in 500ft or 1000ft Tangle-Free Boxes or Spools. Sequential Footage Markings. Construction: Copper Conductors, Genelene Insulation, Polyvinyl-Chloride Jacket. Standard jacket Color: Red. Conductor Color: Chart 4. Fire Alarm Jacketed Unshielded, Riser Rated 75°C 1AWi Nu.] Sot Di m aeter Norn. Cap. cond.j Listings - Ii Avg. Wt. I H Part No. jpffflj 22 4 Solid .122 15 UL, FPLR/CL2R, C(UL), FT4 15 (Lbs.) 4301 144 - -is [ UL, FPLR/CL2R C(UL FT4 [ Lbs 19 () 4302' - 22 8 Solid .156 15 UL, FPLR/CL2R, C(UL), FT4 4303' 22 107od 182 15 IlL2 FPLR/CL2R, C(UL), FT4 L 30 (Lbs) 4304. 22 12 Solid .188 15 UL, FPLR/CL2R, C(UL), F14 4305. [8JE2TESOl,d'r i34 19 - IlL, FPLR/CL2RC(LJLFT4 17(Lbs) - 4306 18 4 Solid .170 19 UL, FPLR/CL2R, C(UL), F14 34 (Lbs.) 4307 192 19 [ UL FPLR/çL2R, C(LJLkFT4 r - 44 (Lbs) 4308 + 18 5 Solid .205 19 IlL, FPLR/CL2R, C(UL), FT4 54 (Lbs.) 4309+ 13 orsid - 244 - 19 - UL, (U - [ 67 (Lbs) J4310 + 16 2 Solid .154 20 UL, FPLR/CL2R, C(UL), FT4 24 (Lbs.) 4311 rTiT o LI QJ - J4,2 . 14 2 Solid .184 22 UL, FPLR/CL2R, C(UL), F14 37 (Lbs.) 4313 + - 4 olid 214 - 22 [ UL, FPLR/CL2R, C(UL), F14 - 65 (Lbs .4314 + 12 2 Solid .214 22 UL, FPLR/CL2R, C(UL), F14 55 (Lbs.) 4315+ + Spools Only 'Consult Factory for Availability For Technical assistance call: Toll Free 800.222.0060 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE ICAL FIRE LISTING No 7161-1487:100 Page 1 of 1 CATEGORY: LISTEE: DESIGN INSTALLATION MARKING: APPROVAL: Cables-Fire Protective Signaling Genesis Cable System, 7701 95th Street, Pleasant Prairie, WI 53158-2716 Contact: Orville Allen (262) 947-0720 Fax (262) 947-0724 Model FPL, FPLP and FPLR power limited fire protective signaling cable. Conductors: In accordance with the standard Insulation: GPT-150, Foam PP, HDPE or LDPE Assembly: 2 to 12 insulated conductors Shield (Optional): Aluminum polyester tape shield Braid (Optional): Metal braid over cable core Jacket: PVC compound Gitto/Global Corp., Grade GA-91-84, GPT-45, GA5033, GA93016 Refer to listee's data sheet for detailed product description and operational considerations. In accordance with listee's printed installation instructions, applicable codes & ordinances, NEC Article 760, and in a manner acceptable to the authority having jurisdiction. Listee's name, Type "FPL" and UL label. Listed as power-limited fire protective signaling cables. Rev. 06-18-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 24, 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering Division 4P-loneywell.com 4ACS 4Security ARTICLE 760 Fire Alarm Systems L Jacketed Cables Unshielded Direct Burial Cable Applications: Wiring For Outdoor or Underground. Sunlight Resistant. Lode Resfrktions:OK for Use with all Power-Limited Circuits except those in risers and plenums but intended For Outdoor or Underground Use. Feitutes Aalable in 5DUft. or 1000ft spools. Sequential Footage Markings. Construction: Stranded copper Conductors ,PVC Insulation, Right floiècuier Weight PVC. Jacket Color: 8làckConductor Color Chart 4 Five Alarm Jacketed Unshielded 75C AWG No. 1strand. Nom. Rom Cap. Listings Avg. WtfNftPi II Cond. Solid 0.1). .1 nIl Ft I 16 2 Stranded .282 ,i _lE II Strandedj _.310 14 4 Stranded .355 18 2 1 Stranded [ 260 18 4 Stranded .295 18 1 6 Stranded .345 21 FPL,CL2 31 (Lbs.) 23 FPLJCL2 L 23 rPL, CL2 17 (Lbs.) 19 FPLICLZ Ir 95 (Lbs.) 19 FPL, CL2 15 (Lbs.) FPL, CL2 24 (Lbs.) 4151 4153 4154 - 4156 4157 4158 For Technical assistance call: Toll Free 800.222.0060 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0559:149 Page 1 of 1 CATEGORY: Photoelectric Smoke Detector LISTEE: Silent Knight Security, 7550 Meridan Circle, Maple Grove, MN 55369 Contact: Mike Mclsaac (763) 493-6424 FAX (763) 391-5464 DESIGN: Models lDP-PHOTO, lDP-PHOTO-T and IDP-ACCLIMATE photoelectric type smoke detectors. Model IDP-PHOTO-T employs a 1350F supplement integral heat sensor which only assists in a fire situation. This thermal circuitry is NOT approved for use in lieu of a required heat detector. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number, electrical rating and UL label. APPROVAL: Listed as photoelectric type smoke detector for use with listee's separately listed compatible base and fire alarm control units. Models lDP-PHOTO, lDP-PHOTO-T and lDP-ACCLIMATE are suitable for open areas and inside duct installation with air velocities between 0-4000 fpm. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires that smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. XLF: 7272-0028:206 05-25-2006 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 6, 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering Division Name of protected property: ro' Address:_(' Z iQ L / Representative of protected property Authority having jurisdiction:. (ai Address /telephone number: A FIRE ALARM SYSTEM RECORD OF POMPLETION 7, 1. Type(s) of System or Service _____ NFPA 72, Chapter 3 - Local If alarm is transmitted to location(s) off premises, list where received: 44 NFPA 72, Chapter 3 - Emergency Voice/Alarm Service Quantity of voice/alarm channels: Single: Multiple: Quantity of speakers installed: Quantity of speaker zones: Quantity of telephones or telephone jacks included in system: u/A NFPA 72, Chapter 6 —Auxillary Indicate type of connection: Local energy Shunt Parallel telephone Location of telephone number for receipt of signals: NFPA 72, Chapter 5 - Remote Station Alarm: 4/ Supervisory: A NFPA 72, Chapter 5 - Proprietary If alarms are retransmitted to public fire service communications centers or others, indicate location and telephone numbers of the organization receiving alarm: Indicate how alarm is retransmitted: NFPA 72, Chapter 5—Certral Station - Prime contractor: (4 t Ltj r - %. i S Central station location: C4 Means of transmission of signals from the protected premises to the central station: McCulloh Multiplex One-way radio Digital alarm communicator Two-way radio Others Means of lransmIsson of alarms to the public fire service communications center: (a)()bh (b) k-k L System location: i5 (NFPA Record of Completion 1 of 4) Organization name/phone Representative name/phone Installer 14. E. .'S jasr JJ' 'D Supplier irt.e Wt Pado 313 937 SôO Service organization S. Location of record (as-built) drawings: (U Location of owners manuals: U5t)M94 , Location of test reports: pmul q 14 v' A contract, dated /_Z - , for test and inspection in accorcfnce with NFPA standard(s) No(s). 7 2.. , dated 2_2i 2.— , is in effect. 2. Record of System Installation (Fill out after installation is complete and wiring checked for opens, shorts, ground faults, and improper branching, but prior to conducting operational acceptance tests.) This system has been installed in accordance with the NFPA standards as shown below, was inspected by rcyl on D. - b includes the devices shown below, and has been in service since itSo'( NFPA 72, Chapters 1 2 3 4 5 6 7 (circle all that apply) NFPA 70, National Electrical Code, Article 760 Manufacturer's instructions _qA Othercify): Signed:% " - Date: /Z /-O Organization: /7" . 3. Record of System Operation All operational features and functions of this system were tested by 4 P071 on /2 - ? and found to be operating properly in accordance with the requirements of- - NFPA 72, Chapters 1 2 3 4 5 6 7 (circle all that apply) - NFPA 70, National Electrical Code, Article 760 Manufacturer's instructions _Other cify): 4 4Z Sigued7 ate: 12- Organization: Alarm-Initiating Devices and Circuits Quantity and class of initiating device circuits (see NFPA 72, Table 3-5) Quantity: ..,3 Style: ...P...... Class: MANUAL Manual stations Noncoded, activating 4I Transmitters Coded _______ Combination manual fire alarm and guard's tour coded stations AUTOMATIC Coverage: Complete: tj C-.D Partial: Smoke detectors _______ Ion Photo Al/A Duct detectors 4/14 ____ Ion J/A. Photo N/fr Heat detectors Aifr.- FT IJ/k RR FT/RR A//A RC (NFPA Record of Completion 2 of 4) W r4 Sprinkler waterfiow switches: ______ Transmitters Noncoded, activating Coded (e) PJ/& Other (list): 5. Supervisory Signal-Initiating Devices and Circuits (use blanks to indicate quantity of devices) GUARD'S TOUR iJ/A- Coded stations /'J/Pv' Noncoded stations, activating transmitters 14/A Compulsory guard tour system comprised of Al/A- transmitter stations and 1J /A intermediate stations Note: Combination devices are recorded under 4(b) and 5(a). SPRINKLER SYSTEM _____ Coded valve supervisory signaling attachments Value supervisory switches, activating 441 transmitters i..1/4 Building temperature points tJf4 Site water temperature points is/M. Site water supply level points Electric fire pump: t4/4 Fire pump power 1-J//4. Fire pump running M/i4 Phase reversal Engine-driven fire pump: Selector in auto position Engine or control panel trouble aU/A Fire pump running Engine-driven generator: is/A Selector in auto position (1) __ Control panel trouble (m) _______ Transfer switches (a) P4/4 Engine running Other supervisory function(s) (specify): 6. Alarm Notification Appliances and Circuits Quantity and class (see NFPA 72, Table 3-7) of notification appliance circuits connected to the system: Types and quantities of notification appliances installed: Quantity: 1.45 Style: Class: &IA= Bells ____ Inch 24,1A Speakers N/14. Horns Nik Chimes i4- Other: aU/A (NFPA Record of Completion 3of4) M (0 '1 Visual signals Type: Ll / with audible 1f) W/O audible (g) / Local annunciator 7. Signaling Line Circuits Quantity and class (see NFPA 72, Table 3-6) of signaling line cjrcuits connected to system: Quantity: 7 Style: C Class: '0 8. System Power Supplies Primary (main): /,2o L Nominal voltage: /c 0 1/' Current rating: 04 Overcurrent protection: Type: Current rating: Location: Secondary (standby): Storage battery: Amp-hour rating: 13 1 il Li X Calculated capacity to drive system, in hours: > 24 60 Engine-driven generator dedicated to fire alarm system: Location of fuel storage: Emergency or standby system used as backup to primary power supply, instead of using a secondary power supply: Emergency system described in NFPA 70, Article 700 ,JfA Legally required standby system described in NFPA 70, Article 701 t.t/4- Optional standby system described in NFPA 70, Article 702, which also meets the performance requirements of Article 700 or 701 9. System Software Operating system software revision level(s): Application software revision level(s): Revision completed by: (name) (firm) 10. (siThentral station or alarm service company or installation contractor/supplier (title) (date) Frue of ut tests jandj?sPecti ons, if other than in accordance with the referenced NFPA standard(s): System deviations from the referenced NFPA standard(s) are: 1,2 3(- ° (s for for central station or alarm service company or installation contractor/supplier (title) (date) Up4 completion oJth9 system(s) satisfactory test(s) witnessed (jjuired by the authority having jurisdiction): Aigned)leprisentat'A of the authority having jurisdiction / (title) (da (e) (NFPA Record of Completion 4 of 4)