Loading...
HomeMy WebLinkAbout3821 ADAMS ST; ; FA130068; Permit9/27/22, 11:33 AM FA130068 Permit Data City of Carlsbad Fire Alarm Permit Job Address: 3821 ADAMS ST Permit Type: FALARM Parcel No: 2052700900 Lot #: 0 Reference No.: Permit No: FA130068 Status: APPROVED Applied 10/8/2013 Approved: 10/11/2013 Issued: 10/11/2013 PC #: Inspector: Project Title: ST PATRICKS PARISH REMODEL INSTALL NEW ADDRESABLE FA SYSTEM IN CHURCH. WILL PROVIDE SPRINKLER MONITORING, NOTIFICAITON TO OCCUPANTS & DUCT SMOKE' DETECTION ON AIR MOVING SYSTEMS EXCEEDING 2000 CFM. THE FA WILL BE MONITORED BY A UL LISTED MONITORING STATION. Applicant: EMCOM ELECTRONIC SYSTEMS, INC. SUITE H 256 WITHERSPOON WY EL CAJON, CA 619-667-1200 Owner: ROMAN CATHOLIC BISHOP OF SAN DIEGO P 0 BOX 85728 SAN DIEGO CA rFees Add'I Fees Total Balance L 364 0 364 0 about:blank 1/1 St. Patrick Parish Remodel Alarm System Review Comments. Page 2 Review Comments St. Patrick Parish Remodel Alarm System, 3821 Adams Street, Carlsbad, CA We strongly recommend the following operational tests be performed once the system installation has been completed. A "power off' test, where the normal power supply is shut off, and the system is left to function on battery power alone for a period of 24 hours, at which time the system should still be functioning and operational. At the end of the end of the above test, prior to the primary power being restored, the system should be placed in an "alarm" condition for a period of not less than five minutes, during which time all notification appliances, including the off-station notification, are to function as designed. Once the two prior tests have been completed, the current level in the batteries should be checked, the primary power restored, and at the end of 48 hours the current level checked again to verify that the charging function of the panel is both operational, and able to recharge the batteries within the time period specified by NFPA-72. Once the test in item "c" has been completed, one of the leads to the battery should be disconnected, to determine that the system will provide notification of an "off-normal" power condition to the monitoring company. I .. I EV1COVI ELECTRONIC SYSTEMS, INC. CALIC. 820216 SEC L1CAC03838 256 WITHERSPOQN WAY, SUITE H . ELCAJON, CA 92020 • PH. (619) 667-1200 • FAX (619) 667-1222 Fire Alarm System Equipment Submittal For St. Patrick Parish Church Remodel 3821 Adams St. Carlsbad, Ca. 92008 ]tten pann it hnntt re en d tnt tt ateilt th IL ctIII.IIn pit tbnn' . nt: anti n,tinlaitk it tine ii lie UFtnllC11' a IT tn, let InC fLint nna tOt/n ilpnnIl 1 iii pLllIn nIt Inn n' hi telIttll In dc e\pl e au n iIIl1i fl In tl tilt' tl\ inn .11 tn atat enlie\e he nnv.IIC II n(null it ant ni tint! .itnit,ii CttjlnCCl Of ainlllteci Inc l)!e u.pnnnllt'tIIl lu' lull lui10W with said nttnit' acid itiutdtinl, uutn'llinlltnit the building tilenr Ice atm ce1tiuumsihill inc tklncleiltl e,C finlft. )I Ilis, nIna ntf lltlilfellLC Miltee pIlll n Iieuliei ni muni imi'ied in ihl inn men Lm,nlc/OI ReteW IcMMLND AItIt!lIV,\l l!C!ll\1l'li \ltlnbi tV1! t; "01 I) — - I I INTELLIGENT FIRE ALARM CONTROL PANELS FX-350-60-DR I Features Description The FX-350-60-DR InteIigent Fire Alarm Control Panel is a single loop addressable panel that supports up to 60 addressable points. The FX-350-60-DR is equipped with a twc line by 20 character baclit LCD display, numerical keypad and an integrated UDACT/Digital Communicator. The LC J display allows or 32 characters to be configured for user defined messages. In addition the FX-3EC Series family also includes remote LED and LCD annunciators. The FX-2E0-60-DR is ideal for both new and retrofit applicatio 13. Designed for small to medum commercial, institutional and industrial occupancies, these panels are powerful enough to meet today's installation demands. The FX-350-60-DR is configurable by the keypad for onsite programming or by a PC for both onsite and remote pogramming. Easy to instFP and simple to operate and configure, the FX-350-60-DR enables the installer to configure the system to meet their specific requirements. The FX-350-60-DR is ecuipped with a 5.5 Amp power supply, auxiliary resettable smoke powe-supply (300mA max.), an interface for a Remote Trouble Indicator (RTI- 1) and an RS-485 interface for remote LCD and LED annunciatos. The FX-35J-60-DR comes complete with a red door, black enclD3ure, durable CAT-30 lock and key and space to mount up to 12 AH batteries. An optonal trim ring is available fo- semi-flush mounting. Single Addressable SLC Loop that supports 60 addressable points Points can be any combination of Addressable Sensors or Modules Supports Ionization Sensors, Photoelectric Sensors, Variable Heat Sensors and Multi—Sensor (Heat/Photo) Equipped with a 2 line by 20 character backlit LCD display, numerical keypad and an integrated UDACT/ Digital Communicator LCD display allows for 32 characters to be configured for user defined messages Digital Communicator can be configured for DACT or UDACT mode of operation Configurable via the front panel, PC Configurator, or remote dial up through the built-in modem Sensors can be configured asAlarm, Verified Alarm, Latching or Non-Latching Supervisory, Monitor and Trouble-Only Modules can be configured as Alarm, Latching Supervisory, Non-Latching Supervisory, Water Flow, Monitor, Trouble, Fire Drill Switch, Signal Silence Switch, Aux Disconnect Switch and Buzzer Silence Switch Base panel is equipped with Four Class "B" (Style "B") indicating circuits which may be configured as Class 'A" (Style "Z") using a Class A" signal converter module Indicating Circuits may be configured as Silenceable or Non-Silenceable for both signals and strobes Built-in sync protocols for the following strobe manufacturers: Mircom, Amseco, System Sensor, Gentex, Faraday and Wheelock Relay contacts for Common Alarm, Auxiliary/ Alarm (Disconnectable), Common Supervisory and Common Trouble Configurable Signal Silence Inhibit, Auto Signal Silence and One-Man Walk Test SubsequentAlarm, Supervisory, and Trouble operation RS-485 Interface for Remote LED and LCD Annunciators Positive Alarm Sequence Interface for a Remote Trouble Indicator (RTI-1) Two event history logs comprised of a 200 event alarm log for alarm related events and a 200 event general log for all other events 5.5 Amp Power Supply Optional modules for additional internal relay circuits and City Tie/Polarity Reversal Optional trim ring for semi-flush mounting ® 1•MEA City Of Approved for S7010 7165-1477:156 313-97-E Class 1 ApplicaSons I U I I I I I I I I I El I CATALOG NUMBER NOT TO BE USED FOR INSTALLATION PURPOSES. Mircom reserves the right to make changes at any time without noe in prices, colours, materials, components, equipment, specifications and models and also to discontinue models. I I I I I I I I I I I I I I I I I I I FX-350 Series Installation and Operation Manual Appendix D: Power Supply and Battery Calculations POWER REQUIREMENTS (ALL CURRENTS ARE IN AMPERES) Model Number I Description Qty STANDBY TOTAL ALARM I TOTAL STANDBY ALARM FX-350-60-DR Main Panel c/w Dialer X 0.220 = 0.380 FX-351-LW Main Panel clw 1 RAX- X 0.210 = 0.390 (Note i) FX-353-LW 332 LED Displays FX-351 -LDW/R Main Panel, 01w 1 RAX- 332 LED Displays and X 0.230 0.400 (Note 1) = FX-353-LDR Dialer ALC-252 252 Point Dual Loop X 0.120 = 0.230 Addressable Adder RAX-332 32 LED Display X 0.005 = 0.010 = PR-300 Polarity Reversal and 0.050 = 0.300 = City Tie Module RAM-300- Remote LCD - LCDW/R Annunciator X 0.016 = 0.040 - RAM-208 Remote Annunciator, 8 X 0.0350 = 0.090 = Zone LED RAM-216 Remote Annunciator, 16 X 0.0350 = 0.140 = Zone LED RTl-1 Remote Trouble X 0.035 = 0.035 = Indicator MIX-3000 Ionization Detector X 0.00028 = 0.00028 = MIX-3100 Photoelectric Detector X 0.0004 = 0.0034 = MIX-3200 Multi-sensor Detector X 0.0005 = 0.0035 = MIX-3300 Heat Detector X 0.0005 = 0.0034 = MIX-lOOP Priority Monitor Module X 0.0006 = 0.0046 = MIX-10113 X Mini Priority Monitor 0.0006 = 0.0046 = Module MIX-100R Relay Output Module X 0.00085 = 0.0035 = MIX-100S Supervised Control X 0.00100 = 0.00100 = Module MIX-100X (Kit) 100XH (Isolator) lsolatorc/wMounting 0.000035 = 0.000035 = Base 100XB (Base) MIX-2001R Relay Base X 0.0 0.046 = Device & Remote LEDs (Maximum 30) X Load (bells, horns, strobes, and etc.) Auxiliary 0.0040 Signal pool Power Supply for Annunciators, etc. (SeeNote2) ALARM (B) = Total currents (Add above currents) STAN DBY(A) = 51 MS-71 QIDU ln:eligent Addressable Dual Action Manual Station fl I ALPHA INTELLIGENT ADDRESSABLE MANUAL STATIONS MS-700IDU SERIES - MS-7O1lDU Intelligent Addressable Single Action Manual Station Description Mircom's MS-700IDU Series provide manual fire reporting. These high quality, die-cast metal nteligent Fire Alarm Manual Stations are available in either single or dLal action configurations with a permanently attached addressable module. The MS-700IDU Series stations are available as single or dual-action devices with key resets and a permanently attached addressable module . The addressable manual station has DIP switches which allD/I for address setting. Pulling the handle initiates the operation of the aodressable module. All models are available with CAT-30 keys and mount on a standard single gang backbox, Mircom model BB-700 interior surface metal backbox, or BB-700WP weather proof backbox. Operation The MS-7011DU Single Action Intelligent Manual Station is operated by pulling down the handle marked "PULL HANDLE" on the front of the station. The MS-71 OIDU Dual Action Intelligent Manual Station is operated by pushing the bar labelled PUSH BAR" anc then pulling down the handle marked "PULL HANDLE". The MS-70010U Series Manual Stations are reset by opening the station with the key, placing the handle in the nrmal upright position and re- locking the station. Features Single or Dual Action Key resettable Permanently Attached Intelligent Addressable Module High-gloss red enamel finish Plastic breakrod Meets ADA 5 lb. maximum manual-force Mounts on standard single gang box, Mircom's BB-700 surface metal backbox or BB-700WP weather proof backbox Specifications The manual station shall be Mircom's MS-7001DU Series. Operating instructions shall be in raised English lettering and the unit shall be constructed of high quality die-cast metal and finished in red enamel paint to provide quick identification. Pulling the handle shall initiate immediate operation of the intelligent addressable module. All manual fire alarm stations shall be installed as per the specific requirements outlined in the UL codes, as well as all other applicable national or local codes. Final acceptance is subject to the local authority having jurisdiction. 7150-1477:128 S7005 S7005 CATALOG NUMBER 5679 NOT TO BE USED FOR INSTALLATION PURPOSES. - Mircom reserves the rig r. to make changes at any time without notice in prices, colours, materials, components, equipment, specifications and models and also to discontinue models. I ALPHA INTELLIGENT ADDRESSABLE DETECTORS MIX-3000 SERIES .lIl I I MIX-3000 MIX-3100 Ionization Smoke Detector Photoelectric Smoke Detector MIX-3200 MIX-3300 Multi-Sensor Detector Thermal Detector Description Mircom's Alpha Series Intelligent Addressable Detectors are designed to meet a wide range of applications. The detector's address is set in its base providing a convenient and trouble free maintenance procedure. The detectors mount into a selection of base styles to accommodate installation requirements. Intelligent Ionization Smoke Detector (MIX-3000) The Ionization smoke detector incorporates a unique dual chamber design to respond quickly and dependably to a broad range of fires. The ionization detector is equipped with a red LED which flashes when the detector is polled and turns on steady when the detector goes into alarm. (UL Listed) Features Low profile design For use with the FX-350 Series Fire Alarm Control Panels Fast response time Automatic addressing with the MIX-ADD card Variety of mounting bases Ease of installation Elegant, unobtrusive design Digital communications Intelligent Multi-Sensor Detector (MIX-3200) The Intelligent Multi-Sensor Detector is a photoelectric smoke detector with a supplementary thermal sensor. The Multi-Sensor detector combines photoelectric smoke and thermal sensor values to provide enhanced detection performance and reduction of false alarms. Information from each sensing element is processed and conditioned by an on-board advanced technology ASIC and digitally transmitted to the FACP as a single analog value comprised of the combined responses from both the photoelectric smoke and thermal detection elements. Intelligent Thermal Detector (MIX-3300) The Intelligent Thermal Detector utilizes state of the art electronic temperature sense to provide fast and accurate I I I I temperature monitoring. The thermal detector features Intelligent Photoelectric Smoke Detector (MIX-3100) an adjustable termperature range that is configured from The Intelligent photoelectric smoke sensor utilizes the FX-350 Series fire alarm control panel. I a unique optical sensing chamber that is designed to sense smoke produced by a wide range of combustion sources. The photoelectric detector is equipped with a clear LED which flashes when I the detector is polled and turns on steady when the S6295 S6965 7271-1477138 MIX-3000. MIX-3100 (MIX-3100 detector goes into alarm. (MIX-3000) & MIX-3200) S MIX-3200) 7272-1477:131 S6299 37498 (MIX-3100) 7272-1477:142 (MIX-3300) (MIX-3300) I (MIX-3200) (MIX-3300) 7270-1477:139 CATALOG NUMBER 5676 NOT TO BE USED FOR INSTALLATION PURPOSES. Mircom reserves the right to make changes at any time without notice in prices, colours, materials, components, equipment, specifications and models and also to discontinue models. I ALPHA INTELLIGENT ADDRESSABLE MODULES MIX-100 SERIES I Ill L<-1O1P MIX- 1 C C P MIX-100S MIX-bOX Description Mircom's Alpha Series Intelligent Addressable Modules are designed to meet a wide range of applications. The monitor and control modules can be used to supervise and activate sounders, strobes, door closers, pull stations, waterflow switches, conventional smoke detectors and more. An eight position dip switch allows for the address setting of the device and the wiring class/style of the devices that are connected to the module. All modules mount in a standard 4" x 4" x 2 1/8" junction box. Intelligent Addressable Priority Monitor Module (MIX-lOOP) The Intelligent Addressable Priority Monitor Module (MIX-100P) provides an address for a group of UL/ ULC Listed normally open (N.O.) initiating devices, such as heat detectors, beam smoke detectors, 4- wire smoke detectors, waterflow switches, manual pull stations, etc. wired in a Class A (Style D) or Class B (Style B) initiating circuit. The MIX-100P is equipped with a priority interrupt to provide a fast response to emergency conditions. The MIX-100P has an activated red LED. Features Designed to meet a wide range of applications For use with the FX-350 Series FireAlarm Control Panels Fast response time Priority Interrupt feature on monitor modules Monitor modules can be wired as a Class A (Style D) or Class B (Style B) Each module can be addressed from 1 to 126 Eight position dip switch for address setting Red light indicator Modules mount in standard 4" junction box Intelligent Addressable Priority Mini-Monitor Module (MIX-IOIP) The Intelligent Addressable Priority Mini Monitor Module provides an address for a group of UL/ULC Listed Normally Open (N.O.) initiating devices, such as heat detectors, projected beam smoke detectors, 4-wire smoke detectors, waterflow switches, manual pull stations, etc. wired in a Class A (Style D) or Class B (Style B) initiating circuit. The MIX-IOIP is equipped with a priority interrupt to provide a fast response to emergency conditions. The MIX-I01P has an activated red LED. Intelligent Addressable Relay Module (MIX-IOOR) The Intelligent Addressable Relay Module connects to the same loop as the initiating devices and provides two isolated sets of Form-C contacts to control a variety of normally open or normally closed contact applications cuch as fan operation and door closures. The MIX-IOOR has an activated red LED which follows the state of the relay contacts. @ @ 0 S5434 S5434 7150-1477:156 CATALOG NUMBER 5675 NOT TO BE USED FOR INSTALLATION PURPOSES. Mircom reserves the right to make changes at any time without notice in prices, colours, materials, components, equipment, specifications and models and also to discontinue models. SYSTEM $ SENSOR 4-Wire Photoelectric Duct Smoke Detector The lnnovairFlex'° Series are the only duct smoke detectors flexible enough to fit configurations from square to rectangular and everything in between. Features Photoelectric, integrated low-flow technology Air velocity rating from 100 ft/min to 4,000 ft/mm (0.5 m/s to 20.32 m/sec) Versatile mounting options: square or rectangular configuration Plug-in sensor offers superb false alarm immunity and the latest sensor technology Broad ranges for operating temperature (-4°F to 158°F) and humidity (0% to 95% non-condensing) Patented sampling tube installs from front or back of the detector with no tools required Increased wiring space with a newly added 3/4-inch conduit knockout One easy-access Test/Reset button and improved LED status Patented interconnect feature for multi-fan shutdown New high contrast terminal designations Built-in short circuit protection from operator wiring errors Field selectable settings for configuring the detector Two DPDT Form-C relay contacts 24VAC/DC or 120 VAC Backward compatibility with existing Innovair products, including remote accessories Innov PDX- The InnovairFiex D4120 4-wire photoelectric duct smoke detector features a pivoting housing that fits both square and rectangular footprints and mounts to round or rectangular ductwork. This unit senses smoke in the most challenging conditions, operating in airflow speeds of 100 to 4,000 feet per minute, temperatures of —4°F to 158°F, and a humidity range of 0 to 95 percent (non- condensing). A plug-in sensor head offers improved false alarm immunity and simple installation, testing, and maintenance. An improved cover design isolates the sensor head from the low-flow feature for simple maintenance. The InnovairFIex housing provides ample wiring space, a 1/4-inch conduit knockout, and built-in short circuit protection to prevent damage to sensitive components during installation. High contrast terminal designations make wiring easy. With its 2:1 sensor-to-power capability, the power board of the D4120 may be used to monitor a second sensor, D4S, simultaneously (i.e., supply and return side). As many as 50 InnovairFIex detectors can be interconnected. When one unit senses smoke, all interconnected detectors will switch their relays; only the detector sensing smoke will go into alarm, thus pinpointing the fire source. An easy-access Test/Reset button makes it possible to test the unit with the cover on. Three DIP switches can be used to configure field selectable settings: cover tamper delay, number of sensors to be controlled, and shut down on trouble option. Each power board has two LEDs that can be used to indicate the status of connected sensors, and a quick reference imprinted on the cover explains the LED status indications (Standby, Maintenance, Trouble, and Alarm). The lnnovairFlex duct smoke detector can be customized to meet local codes and specifications without additional wiring. The new Agency Listings lnnovairFlex product line is compatible with all previous Innovair models, including remote test accessories. MSFM area WARNING: Duct smoke detectors are NOT a substitute for open smoke detectors; NOT a substitute for early warning detection; LISTED APPROVED approved NOT a replacement for a building's regular fire detection system. 09fO Refer to NFPA 72 and 90A for additional information. InnovairFlex' Duct Smoke Detector Specifications I he air duct smoke detector shall be a Systern Sensor lrrnovairFlex D4120 Photoelectric Duct Smoke Detector: 1 he detector housing shall be UL listed per UL 268A specifically for rise in air handling systems.The flexible housing of the duct smoke detector fits multiple footprints from square to rectangular The detector shall operate at air velocities of 100 feet per minute to 4000 feet per minute (0.5 to 20.32 meters/second), The unit shall be capable of controlling up to 50 air handling systems when interconnected with other detectors. The detector shall be capable of providing a trouble signal in the event that the front cover is removed. It shall be capable of local testing via magnetic switch, test button on the cover, or remote testing using the SSK451 Multi-Signaling Accessory or the RTS'lSl KEY Remote Test Station. Terminal connections shall be of the strip and clamp method suitable for 12-18 AWG wiring. Size: (Rectangular Dimensions) 14.38 in (37 cm) Length; Sin (12.74 cm) Width; 7.5 in (6.36 cm) Depth (Square Dimensions) 7.75 in (19.7cm) Length; 9 in (22.9 cm) Width; 2.5 in (6.35 cm) Depth Weight: 2.5 lbs (1.14 kg) Operating Temperature Range: 04120 & D4S: -4 to 158F )-20 to 70CC); D4P120: -40 to 158F (-40W to 70CC) Storage Temperature Range: 04120 & D4S: -22 to 158T (-30 to 7020; D4131 20: -'10 to 1587 (-40 to 70CC) Operating Humidity Range: 0% to 95% relative humidity non-condensing Air Duct Velocity: 100 to 4000 ft/min AS to 70.32 rn/set) Power supply voltage: 70-79 VDC 74 VAC 50-60 H7 170 VAC 50-60 H7 Input capacitance! 270MFmax. 270pFmax. N/A Reset voltage: 3.0 VDC mm. 2.0 VAC mm. 10 VAC mm. Reset time: (with R1S451) .03 to 0.3 sec. .03 to 0.3 sec. .03 to 0.3 sec. Reset time: (by power down) 0.6 sec. rrlax. 0.6 sec. Max. 0.6 sec. rrrax. Power up time: I 35 sec. max. 35 sec. max. 35 sec. Max. Alarm response time: 15 sec. 15 sec. sec. -15 Sensitivity Test; See detector label See detector label See detector label I Current Requirements: (Using No Accessories) Max. standby current: 21 mA @ 24VDC 65 mA RMS @ 24VAC 60Hz 20 mA RMS @ 120VAC 60Hz Max, alarm current: • 65 mA @ 24VDC 135 mA RMS @ 24VAC 60Hz 35 mA RMS @ 120VAC 60Hz I Alarm initiation contacts: (SPST) 2.OA @30 VDC (resistive) Alarm auxiliary contacts: (DPDT) 10A @30 VDC (resistive); 10A @750 VAC (resistive); 1/2 HP @740 VAC; 1/4 HP @ 120 VAC Note: Alarm auxiliary Contacts shall not be connected to initiating circuits of control panels. Use the alarm initiation contact for this purpose. I Supervisory contacts: (SPOT) ON WI I'll 111 4 Device 2.OA @30 VDC (resistive); 2.0A @ 125 VAC (resistive) . ' Standby Trouble - i- Ti1 Alarm APA1 51/APA4S 1 12.5 mA n/a 30 nrA Max. MHR/MHW OmA n/a 29 mA Max, RA100Z OmA n/a 12mAMax. RTS151/RTS151KEY 0rnA/12mA n/a 12mAMax. RTS7/RTS2-AOS 3,0mA max 16 mA Max. with strobe: 55 mA max; without strobe 30 mA max Note: Any combination of accessories may I be used such that the given accessory loads are: 110 mA or less at the Aux output, and 50 mA or less at the Alarm output Installing the InnovairFiex Sampling Tube The InnovairFiex sampling tube may be installed from the front or back of the detector. The tube locks securely into place and can be removed by releasing the front or rear locking tab (front locking tab shown below right). NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERNOTIFICATION.COM OR CONTACT COOPER NOTIFICATION FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: General Notes * Strobes are designed to flash at I flash per second minimum over their Regulated Voltage Range'. All candela ratings represent minimum effective strobe intensify based on UL Standard 1971. Series Exceder Strobe products are Listed under UL Standards 1971 and 464 for indoor use with a temperature range of 32'F to 120'F )0'C to 49'C) and Maximum humidity of 937, )i 2%) UL 464 )85% UL 1971) Series Exceder horns are under IlL Standard 464 for audible signal appliances(Indoor use only) -ILow LCurrent ii I]1YiT FewerPower Su J I] 1* Strobe Ratings per UL Standard 1971 UL Max 24VDC/24FWR 12 VDC Model Regulated Voltage Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 ST 80-33.0 0.057 0.070 0.085 0.135 0.163 0.182 0.2051 0.253 0.110 0.140 STC 8.0-33.0 0.061 0.085 0.103 0.135 0.163 0.182 10.205 0.2til 0.110 Horn Strobe Ratings per UL 1971 & UL 464 at 24 VDC 01 UL Max Currerl at 99 dBA 24 VDC 12 VDC Model Regulated Voltage Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 1185 15 15/75 HS 8.0-33.0 0.082 0.095 0.102 0.148 0.176 0.197 0.242 0.282 0.125 0.159 HSC 8.0-33.0 0.082 0.102 0.141 0.148 0.176 0.197 0.242 0.284 0.125 UL Max Current* at 95 dBA .1I. 24 VDC 12VDC Model Regulated Voltage Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.073 0.083 0.087 0.139 0.163 0.186 0.272 0.122 0.153 HSC 8.0-33.0 0.073 0.087 0.128 0.139 0.163 0.186 0.230 0.272 0.122 UL Max Current* at 90 dBA m. 24 VDC 12 VDC Model Regulated Voltage Range VDC 15 15/75 30 60 75 95 110 1151135 150 177 185 15 15/75 HS 8.0-33.0 0.065 0.075 - 0.084 0.136 0.157 0.184 0.267 0.120 0.148 HSC 8.0-33.0 0.065 0.084 0.120 0.136 0.157 i., I .120 Horn Ratings per UL 464 - Model Regulated Voltage Range VDC 99 dB 95 dB 90 dB HN 16-33.0 0.064 0.044 0.022 HNC 16-33.0 0.084 0,044 0.022 HN 8.0-17.5 0.047 0.026 0.017 HNC 8.0-17.5 0.047 0.026 0.017 Ike. I hu t * UL max current rating is the maximum RMS Current within the listed voltage range (16-33 VDC for-24 VDC units). For strobes the UL max current is usually at the minimum listed voltage (16 VDC for 24 VDC units). For audibles the max current is usually at the maximum listed voltage (33 VDC for 24 VDC units). For unfiltered ratings, see installation instructions. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-1477:0156 Page 1 of 2 CATEGORY: 7165-- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: MIRCOM TECHNOLOGIES, LTD.25 Interchange Way, Vaughan, Ontario L4K 5W3 Canada Contact: Mara Cherubin (888) 660-4655 Ext: 3110 Fax (888) 660-4113 Email: mcherubin@mircom.com DESIGN: Models FX-350-60-R, FX-350-60-DR, FX-350-126-R, FX-350-126-DR, FX-351-LW, FX-351-LDW, FX-353-LDR, FX-353-LDW and FX-350-378-DR fire alarm control units. Local, auxiliary, remote station (PPU), central station (PPU), waterflow and sprinkler supervisory services. Refer to the listees data sheet for detailed product description and operational considerations. System components: MD-815; FX-350/FX-351 Mainboard - with Dialer MD-837; FX-350/FX-351 Mainboard - No Dialer MD-749; DSP Core Board MD-819; Power Supply Board PR-300; City Tie/Polarity Reversal TR-061; 120/240 VAC Transformer CH-613; FX-350 Backbox FX-350 Door FX-350 Deadfront FX-351 Deadfront FX-351 Door FX-351 Backbox MD-825; RAX 232 RAM-300-LCD; Remote LCD Annunciator MIX-1 OOP; Priority Monitor Module MIX-101P; Mini Priority Monitory Module MIX-100S; Supervised Control Module *MlX100R; Addressable Dual Relay Output Module MIX-i OOX; Isolator Kit I I I I I I I *Rev. 02-07-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed f\ the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct V' operational requirements or installation criteria. Refer to listees data sheet, installation instructions and/or other Date Issued: July 01, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division I ri I I I I I I I Listing No. 7165-1477:0156 Page 2 of 2 RATING: 120 VAC, 60Hz 240 VAC, 50 Hz INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances, and in a manner acceptable to the authority having jurisdiction MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as fire alarm control units for use with listee's separately listed electrically and functionally compatible initiating and indicating devices as indicated in design. Refer to listee's Installation Instructions Manual for details. These control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. This control panel meets the requirements of UL-864, 9th Edition. Rev. 02-07-1391 i This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division I .. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION I OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM I LISTING SERVICE LISTING No. 7150-1477:0128 Page 1 of 1 I CATEGORY: 7150-- FIRE ALARM PULL BOXES LISTEE: MIRCOM TECHNOLOGIES, LTD.25 Interchange Way, Vaughan, Ontario L4K 5W3 Canada Contact: Mara Cherubin (888) 660-4655 Ext: 3110 Fax (888) 660-4113 I Email: mcherubin@mircom.com DESIGN: Models MS-701U, -703U, 704U, -710U, -713U, -714U, 701ADU, -710ADU, -702U, -702ADU, -70IUP, -710UP, -703U(C), -704U(C), -713U(C), -714U(C), -705U, -715U,-706U(C), -716U(C), I -707U(C), -717U(C) and -708 fire alarm boxes. These devices are manually actuated, single or dual action non-coded, fire alarm boxes. Units are to be mounted on standard outlet boxes or listee's Model BB-700 backbox for indoor use only and BB-700WP backbox for indoor and I outdoor use. Models MS- 7011D(U), -702lD(U) and -710lD(U) non-coded, indoor use only, fire alarm boxes. To be mounted on three-inch deep outlet boxes. I Refer to listee's data sheet for additional detailed product description and operational considerations. I RATING: 30VDC, 1A, 125 VAC, 1A INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. I MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as fire alarm manual pull stations for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. I * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition with California amendments. I I II] *Updated 06-19-2009 fm 1 6TI This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct I operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other I Date Issued: July 01, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division I I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION I OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM I LISTING SERVICE LISTING No. 7272-1477:0131 Page 1 of 1 I CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: MIRCOM TECHNOLOGIES, LTD.25 Interchange Way, Vaughan, Ontario L4K 5W3 Canada Contact: Mara Cherubin (888) 660-4655 Ext: 3110 Fax (888) 660-4113 I Email: mcherubin@mircom.com DESIGN: Model MIX-3100 photoelectric smoke detector. Refer to listee's data sheet for additional detailed product description and operational considerations I RATING: Electrical: 17 to 28 VDC, 5 to 9V protocol INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances I and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as a photoelectric smoke detector for use with listee's separately listed compatable I fire alarm control units and listed Models MIX-2000 Series detector bases (CSFM Listing No. 7300-1477:145). Refer to listee's Installation Instruction Manual for details. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering I fires which smolder for hours before bursting into flames. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a I grease fire in the kitchen XLF: 7272-1394:0104 I I I III II 04-06-2005 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering the test results and/or other data but does not make an independent verification of any claims. staff has reviewed This listing is not an endorsement or recommendation of operational requirements or installation criteria. the item listed. This listing should not be used Refer to listee's data sheet, installation instructions and/or other to verify correct I Date Issued: Authorized By I July 01, 2013 JAMES PARSEGIAN, Program Coordinator Fire Engineering Division Listing Expires June 30, 2014 1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION I OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM I LISTING SERVICE LISTING No. 3242-1653:0207 Page 1 of 1 I CATEGORY: 3242 -- DUCT SMOKE DETECTOR, PHOTO. (W/ OR W/O BASE) LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 I Contact: Trish Linhart (630) 377-6580 Fax (630) 377-7245 Email: trish.linhart@systemsensor.com DESIGN: Models D4120, D4240, RD4120, P270-3000PL, 1D41203, TD41204, LD4S, LD412OX, I LD412OH, D4S, D4P120, CD4P12O LD4P12OX, LD4P12OH, TD4C, PD4120, YD4120, YD4P12O, and AD4P12O four-wire conventional photoelectric duct smoke detectors and subassemblies. Unit consists of a duct detector housing, powerboard with electrical components and relays, exhaust tubes, and listed 2D51 detector head (CSFM Listing No. I 7272-1653:203). ModelAD4S sensor component. Models *TD4C, LD412OX, LD4120H, LD4P120X and LD4P120H do not contain a 120 VAC transformer. Refer to listee's data sheet for additional detailed product description and operational considerations. I RATING: 20-29 VDC, *24 VAC, 120 VAC (except Models *TD4C LD412OX, LD4120H, LD4P120X and LD4P120H *do not have 120 VAC rating). INSTALLATION: In accordance with listee's printed installation instruction, applicable codes and ordinances I and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, rating, air velocity and UL label. APPROVAL: ' Listed as conventional photoelectric duct smoke detector for use with separately listed fire alarm control units. Refer to listee's Installation Instruction Manual for details. I I I I *Rev. 03-27-13 gt I This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not I V' an endorsement or recommendation of operational requirements or installation criteria. the item listed. This listing should not be used to verify correct Refer to listee's data sheet, installation instructions and/or other I Date Issued: July 01, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division I I I I I I I I I I I I I I I I I I I I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1653:0212 Page 1 of 1 CATEGORY: 7300-- FIRE ALARM CONTROL UNITACCESSORIESIMISC. DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Irish Linhart (630) 377-6580 Fax (630) 377-7245 Email: trish.linhart@systemsensor.com DESIGN: Models RTS151, RTS151KEYand RA100Z Duct Smoke Detector accessories. Referto listee's data sheet for detailed product description and operational considerations. RATING: Refer to the installation manuals. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. 04-03-09 bh is This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed f2\ the test results and/or other data but does not make an independent verification of any claims. This listing is not an en1orsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:0168 Page 1 of I CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Cooper Wheelock lnc.7246 16th St. E., Ste. 105, Sarasota, FL 34243 Contact: Tom Conover (941) 487-2336 Email: thomas.conover@cooperindustries.com DESIGN: Exceder Series: Models ST strobe, HS horn strobe and HN horn. Model ST is a synchronous and non-synchronous strobe light. Model HS a visual/audible appliance and Model HN is an audible signal appliance. All units followed by R (red) or W (white). Additionally, a C may be added for ceiling models and/or a '-NR' may be added for non-resettable models. For non -NR models and optional 'S for silver fascia may be added*. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 12 VDC/24VDC/FWR Candela (wall)*: 15, 15/75, 30, 75, 95, 110, 135 & 185 Candela (ceiling)*: 15, 30, 60, 75, 95, 115, 150, & 177 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. All models are for indoor use and for wall mount only or ceiling mount only* MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as horn for fire alarm signaling and strobe, horn/strobe for the hearing impaired when used with separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instructions Manual for details. I I *Rev. 9-24-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct flV operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division