Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
6600 BLACK RAIL RD; ; AS090023; Permit
9/27/22, 11:35 AM AS090023 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS090023 6600 BLACK RAIL Job Address: Status: ISSUED RD SPRINK Applied 3/23/2009 2150811400 Approved: 3/23/2009 0 Issued: 3/23/2009 Inspector: REDEEMBER BY THE SEA SIX FIRE SPRINKLER INSPECTIONS @ $65/EA Permit Type: Parcel No: Lot #: Reference No.: PC #: Project Title Applicant: TRI COUNTY FIRE UNIT I 12221 POPLAR ST HESPERIA, CA 760-948-4414 Owner: REDEEMER BY THE SEA LUTHERAN CHURCH OF CARLSBAD 6600 BLACK RAIL RD CARLSBAD CA Fees Add'I Fees Total Balance 390 0 j 390 0 about:blank 1/1 01/20/2003 13:48 FAX 16 003/004 Flow Test Record Test Ilydrant Hydrant ID No. Size Main______________ Static............. Residual ......... (5"1 P Pressure Drop.. - (Ff1 1) P.... K factor for J'DJ I Flow H'ydrant(s Hydrant I location - Hydrant 2 location Hydrant 3 location Hydrant 1 Pitot PS! GPM: t Size of 0rifice__________ Hydrant 2 Pitot -- PSI GPM: Size of Orifice__________ Hydrant 3 Pitot PSI GPM: Size of Orifice___________ Total:____________ (Q1) Calculated test and flow data OxPD2 k =Q2 PDIk Static'.................... Desired Residual ....... 20 Pressure Drop (PD 2).. KfacTorPD2; x -- divided by________ equals_________ GPM at 20 psi residual Q1 PD2k PD1k Q2 Comments, Test cor.ducted for: -. WIk Conducted by; L Date:____ _____ Time;_Oti' I1004/004 01/20/2008 13:48 FAX Flow Test Record Formulas GPM-Flow 2 W' 4" PSI GPM PSI .GPM PSI GPM PSI . .GPM 1 170 16 670 1 430 16 1720 2 240 17 690 2 610 17 1770 3 290 18 710 3 740 18 1820 4 340 19 730 4 860 19 1870 5 380 20 750 5 960 20 1920 6 410 22 790 6 1050 22 2020 7 440 24 820 7 1140 24 2110 8 480 26 860 8 1220 26 2190 9 500 28 890 9 1290 28 2280 10 530 30 920 tO 1360 30 2330 11 560 33 950 11 1430 32 2430 12 580 34 980 12 1490 34 2510 13 610 36 1010 13 1550 36 2580 14 630 38 1040 14 1610 38 2650 15 650 40 1060 15 1660 40 2720 K Factor Formu1i PD K PD KPD K PD K PD K I= 1.0 21 =; 5.I8 41= 7.43 61= 9.21 81= 10.73 2= 1.45 22= 5.31 42= 7.53 52= 9.29 82= 10.80 3=• 1.81 23= 5.44 43= 7.62 63= 9.37 83= 10.87 4= 2.11 24= 5.56 44= 7.72 64= 9.45 84= 10.94 5= 2.39 25= 5.69 45= 7.81 65= 9.53 85= 11.01 6= 2.63 26= 5.81 46= 7.91 66= 9,61 86= 11.08 7= 2.86 27= 5.93 47= 8.00 67 9,69 87= 11.15 8= 3.07 28= 6.05 48= 8.09 68= 9.76 88= 11.22 9= 3.28 29= 6.16 49= 8.18 69= 9.84 89= 11.29 10= 3.47 30= 6.28 50= 8.27 70= 9.92 90= 11.36 1 I= 3.65 31= 6.39 51= 8.36 71= 9.99 91= 11.43 12= 3.83 32= 6.50 52= 8,44 72= 0.07 92= 11.49 13= 4.00 33= 6.61 53= 8.53 73= 10.14 93= 11.56 14= 4.16 34m, 6.71 54= 8.64 74= 10.22 94= 11.63 15= 4.32 35= 6.82 55= 8.71 75= 10.29 95= 11.69 16= 4.48 36= 6.93 56= ' 8.79 76= 10.37 96= 11.76 17= 4.72 37= 7.03 57 = 8.88 77= 10.44 97= 11.83 18= 4.76 38= 7.13 58= 8.96 78 10.51 98= 11.89 19= 4.90 39= 7.23 59 9.04 79= 10.59 99= 11.96 20= 5.04 40 7.33 60= 9.12 80= 10.66 100= 12.02 *PD = Pressure drop K K factor 01/20/2009 13:48 FAX tj 001/004 . INSTALLATION ' 765 TIrQTLE POINT WAY SAN Z1AX06, CA 9209 TING • IIPC1QN PIIOtE 76.310-622 PAL 760-798-05% P1CFIE@COK.NT 861958 TRANSMITTAL COMPPNY: FROM: ADAM - ATfN: DATE; ADDRESS: NO. OF PACES: FAX NUMBER: REGARDING: NOTESFCOMMENTS: LA -vçci— L)L • City of Carlsbad 01-05-2009 Fire Department Permit Permit No: FAD0900I Job Address: 6604 BLACK RAIL RD CBAD Permit Type: FADD Subtype: HYD Status: PENDING Parcel No: 2150811400 Lot #: 0 Applied: 01/05/2009 Issued: Fire Dept Ref#: FAD09001 Building Permit#: Entered By: BSW Location: Project Title: REDEEMER BY THE SEA Description: HYDRANT FLOW TEST Contractor: TRI COUNTY FIRE Phone: 760-948-4414 UNIT 1 Fax: 12221 POPLAR ST HESPERIA, CA 92344 Total Fees $72.00 Total Payments To Date $0.00 Permit Fee $0.00 Additional Permit Fee $0.00 Re-Inspection Fee 0 $0.00 Other $0.00 Pre-Inspection Fee 0 $0.00 Additional Fees $0.00 TOTAL PERMIT FEES $72.00 NOTICE: Please take NOTICE that approval of your project includes the Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as 'fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. Chck a License or Home Improvement Salesperson (HIS) Registration - Contractors Stat... Page 1 of 1 Department of Consumer Affairs Contractors State LicenBoard Contractor's License Detail - License # 803096 11 DISCLAIMER: A license status check provides information taken from the CSLB license database. Before relying on this information, you should be aware of the following limitations. > CSLB complaint disclosure is restricted by law (ft&E124). If this entity is subject to public complaint disclosure, a link for complaint disclosure will appear below. Click on the link or button to obtain complaint and/or legal action information. >> Per .B.&P 7.Q7L,1J., ony construction related civil judgments reported to the CSLB are disclosed. Arbitrations are not listed unless the contractor fails to comply with the terms of the arbitration. Due to workload, there may be relevant information that has not yet been entered onto the Boards license database. License Number: 803096 Extract Date: 01/05/2009 PONTOLILLO INC dba TRI - COUNTY FIRE Business Information: 12221 POPLAR STREET UNIT 1 HESPERIA, CA 92344 Business Phone Number: (760) 948-4414 Entity: Corporation Issue Date: 01/15/2002 Expire Date: 01/31/2010 License Status: This license is current and active. All information below should be reviewed. The license may be suspended on 01/28/2009 if the workers compensation insurance Additional Status: policy is not filed with the CSLB. CLASS DESCRIPTION Classifications: C16 FIRE PROTECTION CONTRACTOR CONTRACTORS BOND This license filed Contractors Bond number 1030525 in the amount of $12,500 with the bonding company SURETY COMPANY OF THE PACIFIC. Effective Date: 01/01/2007 Bonding: Con ractQrS.,BQfldflg.H..i.sto..y BOND OF QUALIFYING INDIVIDUAL The Responsible Managing Officer (RMO) THOMAS GENE PONTOLILLO certified that he/she owns 10 percent or more of the voting stock/equity of the corporation. 1. A bond of qualifying individual is not required. Effective Date: 01/15/2002 This license has workers compensation insurance with the . M.ERI.0 EN,DI)RANCE . ..EINSUNCQ,QRP.ORA110N.OF ,. Policy Number: WEN100146902 Workers' Compensation: Effective Date: 12/26/2007 Expire Date: 12/26/2008 Workers CornpenstionHistory Personnel listed on this license (current or disassociated) are listed on other licenses. Qqnd.tb...nsof...e I PrivacyPolicy Copyright © 2008 State of California http ://www2.cslb.ca. gov/OnlineServices/CheckLicense/LicenseDetail. asp 01/05/2009 01/20/2009 13:48 FAX t002/004 Carlsbad Municipal Water District Potable Water Discharge Event Report Location; P1 LCkL M! Reason for Discharge Event: -H j d t iD1Z -. j :.cv c -cYl Initial Type of Event: Dewatering Water Mains Note: includes flow tesng and flushing Dewatering Reservoirs Unscheduled Water Discharge Clear flow path of debris, surface contaminants and/or hazardous materials. Do not remove native vegetation. Erosion control, i.e. sandbags, silt fencing, hay bales gravel bags, decreasing the velocity of discharge water. Estimated Discharge Flow: \ t s::c Start Time -. End Time O- Pre-Dechiorination Residual: Post-Dechlorination Residual: (less than 0.1 mgIL) pH within limits of 6.0 and 9.0 Upon completion of dowatering, ensure that the flow path is free of all temporary erosion prevention materials, \/ Upon completion of dewatering, ensure that any sediment or silted areas are cleared. Water Sampling Performed by: E1%b C? JOXC2 tJ' E -. Comments: Submitted by: eview me & & D 24-16 INSTALLATION OF PRIVATE FIRE SERVICE MAINS AND THEIR APPURTENANCES 9,' Contractor's Material and Test Certificate for Underground Piping PROCEDURE Upon completion of work, Inspection and tests shall be made by the contractor's representative and witnessed by an owner's representative. All defects shall be corrected and system left in service before contractors personnel finally leave the job. A certificate shall be filled out and signed by both representatives. Copies, shall be prepared for approving authorities, owners, and contractor. It is understood the owner's representative's signature in no way prejudices any claim against contractor for faulty material, poor workmanship, or failure to comply with approving authority's requirements or local ordinances. Property name , I bate4 z, Property address ' '" Accepted by approving authorities (names) Address Plans Installation conforms to accepted plans .Yes No Equipment used is approved Yes No If no, state deviations Has person in charge of fire equipment been instructed as to location of J Yes No control valves and care and maintenance of this new equipment? If no, explain Instructions Have copies of appropriate Instructions and care and maintenance Yes No charts been left on premises? If no, explain Location Supplies buildings Pipe types and class Type joint Pipe conforms to Fittings standard Yes ED No Underground conforms to standard 0Yes EJ No pipes and joints If no, explain Joints needed anchorage clamped, strapped, or blocked In Yes F1 No accordance with standard If no, explain 4/t2 fri /Q 67 -Flushing: Flow the required rate until water is clear as indicated by no collection of foreign material in burlap bags at outlets such as hydrants and blow-offs. Flush at flows not less than 390 gpm (1476 LJmln) for 4-in, pipe, 880 gpm (3331 1/mm) for 6-in, pipe, 1560 gpm (5905 Lfmin) for 8-in, pipe, 2440 gpm (9235 L/min) for 10-in, pipe, and 3520 gpm (13,323 tJmin) for 12-in, pipe. When supply cannot produce stipulated flow rates, obtain maximum available. y2lfo' CA .Jydrostatic: Hydrostatic tests shall be made at not less than 200 psi (13.8 bar) for 2 hours or 50 psi (3.4 bar) above Test static pressure in excess of 150 psi (10.3 bar) for 2 hours. description Leakage: New pipe laid with rubber gasketed joints shall, if the workmanship is satisfactory, have little or no leakage at the joints. The amount of leakage at the joints shall not exceed 2 quarts per hour (1.89 Lihr) per 100 joints irrespective of pipe diameter. The leakage shall be distributed over all joints. If such leakage occurs at a few joints, the. Installation shall be considered unsatisfactory and necessary repairs made. The amount of allowable leakage specified above can be increased by 1 fluid ounce per Inch valve diameter per hr. (30 mL/25 mm/hr) for each metal seated valve Isolating the test section. If dry barrel hydrants are tested with the main valve open so the hydrants are under pressure, an additional 5 ounces per minute (150 mI/mm) leakage Is permitted for each hydrant. Iew underground piping flushed according to !..Yes E No IL\ ' standard by (company) 1'U P44 If no, explain How flushing flow was obtained Through what type opening Flushing -Public: water ED Tank or reservoir Fire pump Hydrant butt ',Open pipe tests To Lead-Ins flushed according to A &AA/'..4 standard by (company) CR Yes E No If no, explain How flushing flow was obtained Through what type opening -Public water E Tank or reservoir Fire pump E Y connection to flange 'epen pipe and spigot (NFPA 24, 1 o 2) FIGURE 10.10.1 Sample of Contractor's Material and Test Certificate for Underground Piping 2002 Edition Tri County Fire The Silent Fireman - Saves Lives and Property 12221 Poplar St., Unit 1, Hesperia, CA 92344 HYDRAULIC CALCULATIONS COVER SHEET Reedemer by the Sea - Bldg 1 - 1st Floor Rev 1 3-19-09 WATER SUPPLY STATIC PRESSURE (psi) 71 RESIDUAL PRESSURE (psi) 67 RESIDUAL FLOW (gpm) 1185 BOOSTER PUMPS NUMBER OF BOOSTER PUMPS 0 SPRINKLERS MAXIMUM SPACING OF SPRINKLERS (ft) 12.5 MAXIMUM SPACING OF SPRINKLER LINES (ft) 12 SPECIFIED DISCHARGE DENSITY (gpm/sq. ft.) .1 THIS SPRINKLER SYSTEM WILL DELIVER A DENSITY OF .1 gpm/sq. ft. FOR A DESIGN AREA OF 2111 SQ. FT. OF FLOOR AREA THIS SYSTEM OPERATES AT A FLOW OF 491.99 gpm AT A PRESSURE OF 38.18 psi AT THE BASE OF THE RISER (REF. PT. 4) PIPES USED FOR THIS SYSTEM 107 PVC BLUE BRUTE (150) 111 DUCTILE IRON (350) APPRGVE 002 SCHEDULE 10 001 SCHEDULE 40 CARLSBAD FIREAMPARTMENT 0&1000&k12H tall 'a In cliese plat', "'rittact' '1111 -tit app %t the ' ( ill '13 Pkirt 0 TeSs Of %P %C (%Vl'It.f AtC &eves bit "10113 with lk~ a in the Ale tile i"i "rkils. ¼fl I 1,101 i— -,14LYO7 \tThU ('. I •$t) COM - \t 0&1000&1,10H Tri County Fire The Silent Fireman - Saves Lives and Property Reedemer by the Sea - Bldg 1 - 1st Floor Rev 1 3-19-09 PAGE 1 HYDRAULIC CALCULATIONS AT SPECIFIED DENSITY THE FOLLOWING SPRINKLERS ARE OPERATING IN: I TEST AREA 1 [ I] TEST AREA 2 [ I TEST AREA 3 Al REMOTE AREA Elevation of sprinklers = Elevation above water test. REF. PT. K ELEV. FLOW PRESSURE ft gpm psi 101 5.60 6.00 19.47 12.09 102 5.60 6.00 19.95 12.69 103 5.60 7.50 17.42 9.67 104 5.60 6.00 17.99 10.32 105 5.60 7.50 16.07 8.23 106 5.60 6.00 17.02 9.23 107 5.60 6.00 16.48 8.66 108 5.60 7.50 18.43 10.83 109 5.60 6.00 19.28 11.86 110 5.60 6.00 18.36 10.75 111 5.60 5.50 18.91 11.40 112 5.60 6.00 19.03 11.55 113 5.60 6.00 18.26 10.63 114 5.60 6.00 18.20 10.57 115 5.60 6.00 18.17 10.52 116 5.60 6.00 17.71 10.00 117 5.60 6.00 17.36 9.61 118 5.60 7.50 16.28 8.45 119 5.60 6.00 18.05 10.39 120 5.60 6.00 17.82 10.13 121 5.60 6.00 17.73 10.02 122 5.60 5.50 16.74 8.94 123 5.60 5.50 17.24 9.48 124 5.60 7.50 15.38 7.54 125 5.60 5.50 16.56 8.74 126 5.60 7.50 15.00 7.17 127 5.60 5.50 16.40 8.58 128 5.60 6.00 16.67 8.86 THE SPRINKLER SYSTEM FLOW IS 491.99 gpm THE OUTSIDE HOSE FLOW AT REFERENCE POINT NO. 1 IS 100.00 gpm THE INSIDE HOSE [ I RACK SPKLR!S. YARD HYDT. FLOW IS 0.00 gpm 0&1000&k1OH Tri County Fire The Silent Fireman - Saves Lives and Property Reedemer by the Sea - Bldg 1 - 1st Floor Rev 1 3-19-09 PAGE 2 THE MINIMUM DENSITY PROVIDED BY THIS SYSTEM IS 0.100 gpm/sq. ft. THE FOLLOWING PRESSURES & FLOWS OCCUR ---> AT REF. PT. 1 <--- STATIC PRESSURE 71.00 psi RESIDUAL PRESSURE 67.00 psi AT 1185.00 gpm TOTAL SYSTEM FLOW 591.99 gpm AVAILABLE PRESSURE 69.89 psi AT 591.99 gpm OPERATING PRESSURE 42.61 psi AT 591.99 gpm PRESSURE REMAINING 27.28 psi THE ABOVE RESULTS INCLUDE 3.00 psi FRICTION LOSS AT REF. PT. # 2 FOR A [ I BACKFLOW PREVENTER [ 3 METER X] DETECTOR CHECK VALVE [ I OTHER DEVICE E&1000&k10H Tri County Fire The Silent Fireman - Saves Lives and Property Reedemer by the Sea - Bldg 1 - 1st Floor Rev 1 3-19-09 PAGE FITTING Equivalent Length per NFPA 13 1994, 6-4.3 '-' Indicates Equivalent Length. 'T' Indicates Threaded Fitting 1=45 Elbow, 2=90 Elbow, 3='T'/Cross, 4=Butterfly Valve, 5=Gate Valve, 6=Swing Check Valve FROM TO FLOW PIPE FITS EQV. H-W PIPE DIA. FRIC. ELEV. FROM TO DIFF (gpm) (ft) (ft) C TYPE (in) (psi) (psi) (psi) (psi) (psi) 1 2 491.99 35.00 35 50.07 150 107 6.090 0.006 0.000 42.61 42.09 0.52 2 3 491.99 10.00 22552 30.59 100 111 6.400 0.010 0.000 42.09 38.67 3.42 3 4 491.99 125.00 21112 60.14 150 107 6.090 0.006 -0.650 38.67 38.18 1.14 4 5 491.99 7.50 224 33.80 120 2 4.260 0.053 3.250 38.18 32.71 2.21 5 6 491.99 39.50223112 44.48 120 2 3.260 0.195 0.217 32.71 16.08 16.42 6 7 144.85 1.00 3 10.45 120 2 2.157 0.152 0.000 16.08 14.34 1.74 7 101 19.47 11.00 322T 9.00 120 1 1.049 0.124 -0.217 14.34 12.09 2.47 7 8 125.38 4.00 0 0.00 120 2 2.157 0.116 0.000 14.34 13.89 0.45 8 102 19.95 2.00 322T 9.00 120 1 1.049 0.129 -0.217 13.89 12.69 1.42 8 9 105.43 5.00 0 0.00 120 2 1.682 0.283 0.000 13.89 12.49 1.40 9 103 17.42 11.75 332T 12.00 120 1 1.049 0.100 0.433 12.49 9.67 2.39 9 10 88.01 6.25 0 0.00 120 2 1.682 0.203 0.000 12.49 11.22 1.27 10 104 17.99 1.50 322T 9.00 120 1 1.049 0.107 -0.217 11.22 10.32 1.12 10 11 70.02 5.75 0 0.00 120 2 1.682 0.133 0.000 11.22 10.46 0.76 11 105 16.07 11.75 322T 9.00 120 1 1.049 0.087 0.433 10.46 8.23 1.80 11 12 53.95 5.25 0 0.00 120 2 1.682 0.082 0.000 10.46 10.02 0.44 12 106 17.02 1.50 322T 9.00 120 1 1.049 0.096 -0.217 10.02 9.23 1.01 12 13 36.94 13.25 2 3.22 120 2 1.682 0.041 0.000 10.02 9.35 0.68 13 107 16.48 1.00 322T 9.00 120 1 1.049 0.091 -0.217 9.35 8.66 0.91 6 14 347.14 4.50 32 24.12 120 2 3.260 0.102 0.000 16.08 13.17 2.91 14 15 18.43 2.00 3 17.42 120 2 3.260 0.000 0.000 13.17 13.16 0.01 15 108 18.43 5.00 332T 12.00 120 1 1.049 0.112 0.433 13.16 10.83 1.90 14 16 328.70 2.75 0 0.00 120 2 3.260 0.093 0.000 13.17 12.91 0.26 16 109 19.28 1.50 322T 9.00 120 1 1.049 0.121 -0.217 12.91 11.86 1.27 16 17 309.42 3.00 0 0.00 120 2 3.260 0.083 0.000 12.91 12.67 0.25 17 18 56.30 9.50 3T 0.00 120 2 2.157 0.026 0.000 12.67 12.42 0.25 18 110 18.36 5.00 323T 12.00 120 1 1.049 0.111 -0.217 12.42 10.75 1.88 18 19 37.94 8.75 2T 0.00 120 2 1.682 0.043 0.000 12.42 12.04 0.37 19 20 18.91 2.00 0 0.00 120 2 1.682 0.012 0.000 12.04 12.02 0.03 20 111 18.91 2.00 32T 7.00 120 1 1.049 0.117 -0.433 12.02 11.40 1.05 19 21 19.03 5.00 32T 0.00 120 2 1.682 0.012 0.000 12.04 11.98 0.06 21 112 19.03 0.50 3T 5.00 120 1 1.049 0.118 -0.217 11.98 11.55 0.65 17 22 253.12 6.00 22 13.40 120 2 3.260 0.057 0.000 12.67 11.56 1.11 22 23 36.46 0.50 3T 0.00 120 2 1.682 0.040 0.000 11.56 11.54 0.02 23 113 18.26 3.25 32T 7.00 120 1 1.049 0.110 -0.217 11.54 10.63 1.12 23 24 18.20 6.25 0 0.00 120 2 1.682 0.011 0.000 11.54 11.47 0.07 24 114 18.20 3.25 32T 7.00 120 1 1.049 0.109 -0.217 11.47 10.57 1.12 22 25 216.66 6.00 0 0.00 120 2 3.260 0.043 0.000 11.56 11.29 0.26 25 26 69.52 0.50 3T 0.00 120 2 1.682 0.131 0.000 11.29 11.23 0.07 26 115 18.17 1.50 32T 7.00 120 1 1.049 0.109 -0.217 11.23 10.52 0.92 26 27 51.35 7.50 0 0.00 120 2 1.682 0.075 0.000 11.23 10.67 0.56 E&100L1&kl0H Tri County Fire The Silent Fireman - Saves Lives and Property Reedemer by the Sea - Bldg 1 - 1st Floor Rev 1 3-19-09 PAGE 4 FITTING Equivalent Length per NFPA 13 1994, 6-4.3 '-' Indicates Equivalent Length. 'T' Indicates Threaded Fitting 1=45 Elbow, 2=90 Elbow, 3='T'/Cross, 4=Butterfly Valve, 5=Gate Valve, 6=Swing Check Valve FROM TO FLOW PIPE FITS EQV. H-W PIPE DIA. FRIC. ELEV. FROM TO DIFF (gpm) (ft) (ft) C TYPE (in) (psi) (psi) (psi) (psi) (psi) 27 116 17.71 1.50 32T 7.00 120 1 1.049 0.104 -0.217 10.67 10.00 0.88 27 28 33.64 5.00 0 0.00 120 2 1.682 0.034 0.000 10.67 10.49 0.18 28 117 17.36 2.00 322T 9.00 120 1 1.049 0.100 -0.217 10.49 9.61 1.10 28 118 16.28 9.00 322T 9.00 120 1 1.049 0.089 0.433 10.49 8.45 1.60 25 29 147.14 10.00 0 0.00 120 2 3.260 0.021 0.000 11.29 11.08 0.22 29 30 53.61 0.50 3T 0.00 120 2 1.682 0.081 0.000 11.08 11.04 0.04 30 119 18.05 1.00 32T 7.00 120 1 1.049 0.107 -0.217 11.04 10.39 0.86 30 31 35.55 7.25 0 0.00 120 2 1.682 0.038 0.000 11.04 10.75 0.29 31 120 17.82 1.00 32T 7.00 120 1 1.049 0.105 -0.217 10.75 10.13 0.84 31 32 17.73 10.50 0 0.00 120 2 1.682 0.010 0.000 10.75 10.64 0.11 32 121 17.73 1.00 32T 7.00 120 1 1.049 0.104 -0.217 10.64 10.02 0.83 29 33 93.53 10.75 322T 0.00 120 2 2.157 0.068 0.000 11.08 10.35 0.73 33 122 16.74 10.75 322T 9.00 120 1 1.049 0.093 -0.433 10.35 8.94 1.84 34 123 17.24 2.00 322T 9.00 120 1 1.049 0.099 -0.433 10.13 9.48 1.08 33 34 76.79 4.50 0 0.00 120 2 2.157 0.047 0.000 10.35 10.13 0.22 34 35 59.55 5.00 0 0.00 120 2 1.682 0.098 0.000 10.13 9.63 0.50 35 124 15.38 11.75 322T 9.00 120 1 1.049 0.080 0.433 9.63 7.54 1.66 35 36 44.17 6.00 0 0.00 120 2 1.682 0.056 0.000 9.63 9.32 0.31 36 125 16.56 2.00 322T 9.00 120 1 1.049 0.092 -0.433 9.32 8.74 1.01 36 37 27.61 5.75 0 0.00 120 2 1.682 0.024 0.000 9.32 9.19 0.13 37 126 15.00 11.75 322T 9.00 120 1 1.049 0.076 0.433 9.19 7.17 1.58 37 38 12.61 5.25 0 0.00 120 2 1.682 0.006 0.000 9.19 9.13 0.06 38 127 16.40 2.00 322T 9.00 120 1 1.049 0.090 -0.433 9.13 8.58 0.99 38 39 -3.79 13.00 2T 0.00 120 2 1.682 0.001 0.000 9.13 9.15 -0.02 39 128 16.67 0.50 3T 5.00 120 1 1.049 0.093 -0.217 9.15 8.86 0.51 39 13 -20.46 14.00 0 0.00 120 2 1.682 0.014 0.000 9.15 9.35 -0.20 A MAX. VELOCITY OF 18.9 ft./sec. OCCURS BETWEEN REF. PT. 5 AND 6 Sprinkler-CALC Release 7.2 Win By Walsh Engineering Inc. North Kingstown R.I. U.S.A. LIIAI1IIIUU 411111111U..__ 11W111,U.. 1IAl1IuuIU HOME V T iuuuu,INN EA lk I II 14111 uI•II UJItkIurgcIII:IiiuIIz.j.ii Sprinkler-CALC 7.2 Win Tri County Fire The Silent Fireman - Saves Lives and Property 12221 Poplar St., Unit 1, Hesperia, CA 92344 HYDRAULIC CALCULATIONS COVER SHEET Reedemer by the Sea - Bldg 1 - 2nd Floor - Rev 1 3-19-09 WATER SUPPLY STATIC PRESSURE (psi) 71 RESIDUAL PRESSURE (psi) 67 RESIDUAL FLOW (gpm) 1185 BOOSTER PUMPS NUMBER OF BOOSTER PUMPS 0 S P R I N K L E R S MAXIMUM SPACING OF SPRINKLERS (ft) 12.5 MAXIMUM SPACING OF SPRINKLER LINES (ft) 12 SPECIFIED DISCHARGE DENSITY (gpm/sq. ft.) .1 THIS SPRINKLER SYSTEM WILL DELIVER A DENSITY OF .1 gpm/sq. ft. FOR A DESIGN AREA OF 1365 SQ. FT. OF FLOOR AREA THIS SYSTEM OPERATES AT A FLOW OF 243.27 gpm AT A PRESSURE OF 31.75 psi AT THE BASE OF THE RISER (REF. PT. 4) PIPES USED FOR THIS SYSTEM 107 PVC BLUE BRUTE (150) 111 DUCTILE IRON (350) 002 SCHEDULE 10 001 SCHEDULE 40 0&1000&k12H L1&100E&k0H Tri County Fire The Silent Fireman - Saves Lives and Property Reedemer by the Sea - Bldg 1 - 2nd Floor - Rev 1 3-19-09 PAGE 1 HYDRAULIC CALCULATIONS AT SPECIFIED DENSITY THE FOLLOWING SPRINKLERS ARE OPERATING IN: I TEST AREA 1 [ I TEST AREA 2 [ I TEST AREA 3 X REMOTE AREA Elevation of sprinklers = Elevation above water test. REF. PT. K ELEV. FLOW PRESSURE ft gpm psi 201 5.60 19.50 18.15 10.50 202 5.60 21.50 16.17 8.34 203 5.60 18.50 18.18 10.53 204 5.60 19.50 17.72 10.01 205 5.60 21.50 15.45 7.61 206 5.60 18.50 17.37 9.62 207 5.60 19.50 17.61 9.89 208 5.60 21.50 15.10 7.27 209 5.60 18.50 16.97 9.18 210 5.60 21.50 15.00 7.17 211 5.60 18.50 16.86 9.06 212 5.60 19.50 19.80 12.50 213 5.60 21.50 18.85 11.33 214 5.60 18.50 20.04 12.80 THE SPRINKLER SYSTEM FLOW IS THE OUTSIDE HOSE FLOW AT REFERENCE POINT NO. 1 IS I THE INSIDE HOSE { ] RACK SPKLR'S. II YARD HYDT. FLOW IS THE MINIMUM DENSITY PRCVIDED BY THIS SYSTEM IS 243.27 gpm 100.00 gpm 0.00 gpm 0.100 gpm/sq. ft. THE FOLLOWING PRESSURES & FLOWS OCCUR ---> AT REF. PT. 1 <--- STATIC PRESSURE 71.00 psi RESIDUAL PRESSURE 67.00 psi AT 1185.00 gpm TOTAL SYSTEM FLOW 343.27 gpm AVAILABLE PRESSURE 70.60 psi AT 343.27 gpm OPERATING PRESSURE 36.66 psi AT 343.27 gpm PRESSURE REMAINING 33.94 psi THE ABOVE RESULTS INCLUDE 5.00 psi FRICTION LOSS AT REF. PT. # BACKFLOW PREVENTER [ 1 METER DETECTOR CHECK VALVE [ I OTHER DEVICE 2 FOR A 0&1000&k10H Tri County Fire The Silent Fireman - Saves Lives and Property Reedemer by the Sea - Bldg 1 - 2nd Floor - Rev 1 3-19-09 PAGE 2 FITTING Equivalent Length per NFPA 13 1994, 6-4.3 '-' Indicates Equivalent Length. 'T' Indicates Threaded Fitting 1=45 Elbow, 2=90 Elbow, 3='T'/Cross, 4=Butterfly Valve, 5=Gate Valve, 6=Swing Check Valve FROM TO FLOW PIPE FITS EQV. H-W PIPE DIA. ERIC. ELEV. FROM TO DIET (gpm) (ft) (ft) C TYPE (in) (psi) (psi) (psi) (psi) (psi) 1 2 243.27 35.00 35 50.07 150 107 6.090 0.002 0.000 36.66 36.52 0.14 2 3 243.27 10.00 22552 30.59 100 111 6.400 0.003 0.000 36.52 31.41 5.11 3 4 243.27 125.00 21112 60.14 150 107 6.090 0.002 -0.650 31.41 31.75 0.31 4 5 243.27 7.50 224 33.80 120 2 4.260 0.014 3.250 31.75 27.90 0.60 5 6 243.27 39.50 32112 37.78 120 2 3.260 0.053 0.217 27.90 23.60 4.09 6 40 243.27 10.00 3232 48.24 120 2 3.260 0.053 0.000 23.60 20.51 3.09 40 41 243.27 12.00 2 6.70 120 2 3.260 0.053 5.200 20.51 14.32 0.99 41 42 243.27 2.75 3 17.42 120 2 3.260 0.053 0.000 14.32 13.25 1.07 42 43 169.99 11.00 0 0.00 120 2 3.260 0.027 0.000 13.25 12.91 0.33 43 44 89.41 12.00 0 0.00 120 2 3.260 0.008 0.000 12.91 12.83 0.08 42 201 53.48 7.25 33T 16.00 120 1 1.610 0.100 0.433 13.25 10.50 2.32 43 202 61.72 9.25 33T 16.00 120 1 1.610 0.130 1.300 12.91 8.34 3.28 44 203 69.38 6.25 3T 8.00 120 1 1.610 0.161 0.000 12.83 10.53 2.30 201 204 35.34 10.00 0 0.00 120 1 1.610 0.046 0.000 10.50 10.01 0.49 202 205 45.55 10.00 0 0.00 120 1 1.610 0.074 0.000 8.34 7.61 0.73 203 206 51.20 10.00 0 0.00 120 1 1.610 0.092 0.000 10.53 9.62 0.92 204 207 17.61 10.00 0 0.00 120 1 1.610 0.013 0.000 10.01 9.89 0.12 205 208 30.10 10.00 0 0.00 120 1 1.610 0.034 0.000 7.61 7.27 0.33 206 209 33.83 10.00 0 0.00 120 1 1.610 0.043 0.000 9.62 9.18 0.43 208 210 15.00 10.00 0 0.00 120 1 1.610 0.009 0.000 7.27 7.17 0.10 209 211 16.86 10.00 0 0.00 120 1 1.610 0.012 0.000 9.18 9.06 0.12 42 212 19.80 2.75 33T 16.00 120 1 1.610 0.016 0.433 13.25 12.50 0.31 43 213 18.85 4.75 33T 16.00 120 1 1.610 0.014 1.300 12.91 11.33 0.28 44 214 20.04 1.75 0 0.00 120 1 1.610 0.016 0.000 12.83 12.80 0.03 A MAX. VELOCITY OF 10.93 ft./sec. OCCURS BETWEEN REF. PT. 44 AND 203 Sprinkler-CALC Release 7.2 Win By Walsh Engineering Inc. North Kingstown R.I. U.S.A. ills------ Ills------ U's------ IlIIIIIIEl5 I.:j.IiJ. .1 Ii's------ IuIuIliiI...____ I •1'J' 14111 'IiIi a Sprinkler-CALC 7.2 Win Tri County Fire The Silent Fireman - Saves Lives and Property 12221 Poplar St., Unit 1, Hesperia, CA 92344 HYDRAULIC CALCULATIONS COVER SHEET Reedemer by the Sea - Bldg 2 -1st Floor Rev 1 3-19-09 WATER SUPPLY STATIC PRESSURE (psi) 71 RESIDUAL PRESSURE (psi) 67 RESIDUAL FLOW (gpm) 1185 BOOSTER PUMPS NUMBER OF BOOSTER PUMPS 0 SPRINKLERS MAXIMUM SPACING OF SPRINKLERS (ft) 12.5 MAXIMUM SPACING OF SPRINKLER LINES (ft) 12 SPECIFIED DISCHARGE DENSITY (gpm/sq. ft.) .1 THIS SPRINKLER SYSTEM WILL DELIVER A DENSITY OF .1 gpm/sq. ft. FOR A DESIGN AREA OF 2617 SQ. FT. OF FLOOR AREA THIS SYSTEM OPERATES AT A FLOW OF 505.16 gpm AT A PRESSURE OF 38.39 psi AT THE BASE OF THE RISER (REF. PT. 4) PIPES USED FOR THIS SYSTEM 107 PVC BLUE BRUTE (150) 111 DUCTILE IRON (350) 002 SCHEDULE 10 001 SCHEDULE 40 U & 1000 & k12 H 0&100LII&1c10H Tri County Fire The Silent Fireman - Saves Lives and Property Reedemer by the Sea - Bldg 2 -1st Floor Rev 1 3-19-09 PAGE 1 HYDRAULIC CALCULATIONS AT SPECIFIED DENSITY THE FOLLOWING SPRINKLERS ARE OPERATING IN: TEST AREA 1 [ ] TEST AREA 2 [ I TEST AREA 3 N/i REMOTE AREA Elevation of sprinklers = Elevation above water test. REF. PT. K ELEV. FLOW PRESSURE ft gpm psi 101 5.60 6.00 21.05 14.13 102 5.60 6.00 20.95 13.99 103 5.60 6.00 17.99 10.32 104 5.60 7.50 17.73 10.02 105 5.60 6.00 19.16 11.70 106 5.60 7.50 17.90 10.22 107 5.60 7.50 17.80 10.10 108 5.60 6.00 19.37 11.96 109 5.60 6.00 18.99 11.50 110 5.60 7.50 17.72 10.02 111 5.60 7.50 17.63 9.91 112 5.60 6.00 16.15 8.32 113 5.60 7.50 15.79 7.95 114 5.60 6.00 17.89 10.21 115 5.60 6.00 17.79 10.09 116 5.60 6.00 17.85 10.15 117 5.60 6.00 17.74 10.03 118 5.60 6.00 15.63 7.79 119 5.60 7.50 15.24 7.40 120 5.60 6.00 17.49 9.76 121 5.60 7.50 16.24 8.41 122 5.60 7.50 16.19 8.36 123 5.60 6.00 17.47 9.73 124 5.60 7.50 16.26 8.43 125 5.60 7.50 16.17 8.34 126 5.60 6.00 15.35 7.51 127 5.60 7.50 15.00 7.17 128 5.60 6.00 17.36 9.61 129 5.60 6.00 17.26 9.50 THE SPRINKLER SYSTEM FLOW IS 505.16 gpm THE OUTSIDE HOSE FLOW AT REFERENCE POINT NO. 1 IS 100.00 gpm I THE INSIDE HOSE [ I RACK SPKLR'S. 1 YARD HYDT. FLOW IS 0.00 gpm C&lOOU&klOH Tri County Fire The Silent Fireman - Saves Lives and Property Reedemer by the Sea - Bldg 2 -1st Floor Rev 1 3-19-09 PAGE 2 THE MINIMUM DENSITY PROVIDED BY THIS SYSTEM IS 0.100 gpm/sq. ft. THE FOLLOWING PRESSURES & FLOWS OCCUR ---> AT REF. PT. 1 <--- STATIC PRESSURE 71.00 psi RESIDUAL PRESSURE 67.00 psi AT 1185.00 gpm TOTAL SYSTEM FLOW 605.16 gpm AVAILABLE PRESSURE 69.85 psi AT 605.16 gpm OPERATING PRESSURE 42.93 psi AT 605.16 gpm PRESSURE REMAINING 26.92 psi THE ABOVE RESULTS INCLUDE 3.00 psi FRICTION LOSS AT REF. PT. # 2 FOR A I BACKFLOW PREVENTER 1 ] METER f<I DETECTOR CHECK VALVE [ ] OTHER DEVICE 0&1000&k10R Tri County Fire The Silent Fireman - Saves Lives and Property Reedemer by the Sea - Bldg 2 -1st Floor Rev 1 3-19-09 PAGE FITTING Equivalent Length per NFPA 13 1994, 6-4.3 '-' Indicates Equivalent Length. !TI Indicates Threaded Fitting 1=45 Elbow, 2=90 Elbow, 3='T'/Cross, 4=Butterfly Valve, 5=Gate Valve, 6=Swing Check Valve FROM TO FLOW PIPE FITS EQV. H-W PIPE DIA. FRIC. ELEV. FROM TO DIFF (gpm) (ft) (ft) C TYPE (in) (psi) (psi) (psi) (psi) (psi) 1 2 505.16 35.00 35 50.07 150 107 6.090 0.006 0.000 42.93 42.38 0.55 2 3 505.16 10.00 22552 30.59 100 ill 6.400 0.011 0.000 42.38 38.94 3.44 3 4 505.16 125.00 21112 60.14 150 107 6.090 0.006 -0.650 38.94 38.39 1.20 4 5 505.16 7.50 224 33.80 120 2 4.260 0.056 3.250 38.39 32.84 2.30 5 6 505.16 28.00 22311 37.78 120 2 3.260 0.205 0.217 32.84 19.08 13.54 6 7 505.16 1.00 22 13.40 120 2 3.260 0.205 0.000 19.08 16.12 2.96 7 8 463.16 6.75 0 0.00 120 2 3.260 0.175 0.000 16.12 14.97 1.15 8 9 427.45 11.75 0 0.00 120 2 3.260 0.151 0.000 14.97 13.21 1.76 9 10 372.59 1.00 0 0.00 120 2 3.260 0.117 0.000 13.21 13.09 0.12 10 11 353.22 1.00 0 0.00 120 2 3.260 0.106 0.000 13.09 12.98 0.11 11 12 298.88 11.75 0 0.00 120 2 3.260 0.078 0.000 12.98 12.06 0.92 12 13 266.94 7.00 0 0.00 120 2 3.260 0.063 0.000 12.06 11.61 0.46 13 14 231.25 1.25 0 0.00 120 2 3.260 0.048 0.000 11.61 11.55 0.06 14 15 195.67 7.25 0 0.00 120 2 3.260 0.035 0.000 11.55 11.30 0.25 15 16 164.80 11.25 0 0.00 120 2 3.260 0.026 0.000 11.30 10.99 0.31 16 17 114.87 2.00 0 0.00 120 2 3.260 0.013 0.000 10.99 10.96 0.03 17 18 64.97 11.75 0 0.00 120 2 3.260 0.005 0.000 10.96 10.90 0.07 18 19 34.62 6.50 0 0.00 120 2 3.260 0.001 0.000 10.90 10.94 -0.04 7 21 42.00 12.50 322T 0.00 120 2 1.682 0.051 0.000 16.12 15.48 0.64 21 22 20.95 12.00 0 0.00 120 2 1.682 0.014 0.000 15.48 15.33 0.15 9 24 54.86 5.50 3T 0.00 120 2 1.682 0.084 0.000 13.21 12.74 0.46 24 25 35.70 6.50 0 0.00 120 2 1.682 0.038 0.000 12.74 12.50 0.25 25 26 17.80 12.00 0 0.00 120 2 1.682 0.010 0.000 12.50 12.36 0.14 11 27 54.35 5.50 3T 0.00 120 2 1.682 0.083 0.000 12.98 12.52 0.46 27 28 35.36 6.50 0 0.00 120 2 1.682 0.037 0.000 12.52 12.27 0.25 28 29 17.63 12.00 0 0.00 120 2 1.682 0.010 0.000 12.27 12.14 0.12 13 31 35.68 12.00 3T 0.00 120 2 1.682 0.038 0.000 11.61 11.15 0.46 31 32 17.79 12.00 0 0.00 120 2 1.682 0.010 0.000 11.15 11.03 0.12 14 33 35.58 12.00 0 0.00 120 2 1.682 0.038 0.000 11.55 11.09 0.45 33 34 17.74 12.00 0 0.00 120 2 1.682 0.010 0.000 11.09 10.96 0.14 16 36 49.93 5.50 3T 0.00 120 2 1.682 0.071 0.000 10.99 10.60 0.39 36 37 32.44 6.50 0 0.00 120 2 1.682 0.032 0.000 10.60 10.39 0.21 37 38 16.19 12.00 0 0.00 120 2 1.682 0.009 0.000 10.39 10.33 0.06 17 39 49.90 5.50 0 0.00 120 2 1.682 0.071 0.000 10.96 10.57 0.39 39 40 32.43 6.50 0 0.00 120 2 1.682 0.032 0.000 10.57 10.41 0.17 40 41 16.17 12.00 0 0.00 120 2 1.682 0.009 0.000 10.41 10.31 0.10 19 43 34.62 12.50 322T 0.00 120 2 1.682 0.036 0.000 10.94 10.49 0.45 43 44 17.26 12.00 0 0.00 120 2 1.682 0.010 0.000 10.49 10.37 0.12 21 101 21.05 2.00 322T 9.00 120 1 1.049 0.143 -0.217 15.48 14.13 1.57 22 102 20.95 2.00 322T 9.00 120 1 1.049 0.141 -0.217 15.33 13.99 1.56 25 106 17.90 8.50 322T 9.00 120 1 1.049 0.106 0.433 12.50 10.22 1.85 E&1000&k10H Tri County Fire The Silent Fireman - Saves Lives and Property Reedemer by the Sea - Bldg 2 -1st Floor Rev 1 3-19-09 PAGE 4 FITTING Equivalent Length per NFPA 13 1994, 6-4.3 '-' Indicates Equivalent Length. 'T' Indicates Threaded Fitting 1=45 Elbow, 2=90 Elbow, 3='T/Cross, 4=Butterfly Valve, 5=Gate Valve, 6=Swing Check Valve FROM TO FLOW PIPE FITS EQV. H-W PIPE DIA. FRIC. ELEV. FROM TO DIFF (gpm) (ft) (ft) C TYPE (in) (psi) (psi) (psi) (psi) (psi) 26 107 17.80 8.50 322T 9.00 120 1 1.049 0.105 0.433 12.36 10.10 1.83 10 108 19.37 1.00 33T 10.00 120 1 1.049 0.122 -0.217 13.09 11.96 1.35 28 110 17.72 8.50 322T 9.00 120 1 1.049 0.104 0.433 12.27 10.02 1.82 29 111 17.63 8.50 322T 9.00 120 1 1.049 0.103 0.433 12.14 9.91 1.80 31 114 17.89 2.00 322T 9.00 120 1 1.049 0.106 -0.217 11.15 10.21 1.16 32 115 17.79 2.00 322T 9.00 120 1 1.049 0.105 -0.217 11.03 10.09 1.15 33 116 17.85 2.00 322T 9.00 120 1 1.049 0.105 -0.217 11.09 10.15 1.16 34 117 17.74 2.00 322T 9.00 120 1 1.049 0.104 -0.217 10.96 10.03 1.14 37 121 16.24 8.50 322T 9.00 120 1 1.049 0.088 0.433 10.39 8.41 1.55 38 122 16.19 8.50 322T 9.00 120 1 1.049 0.088 0.433 10.33 8.36 1.54 40 124 16.26 8.50 322T 9.00 120 1 1.049 0.088 0.433 10.41 8.43 1.55 41 125 16.17 8.50 322T 9.00 120 1 1.049 0.088 0.433 10.31 8.34 1.53 43 128 17.36 2.00 322T 9.00 120 1 1.049 0.100 -0.217 10.49 9.61 1.10 44 129 17.26 2.00 322T 9.00 120 1 1.049 0.099 -0.217 10.37 9.50 1.09 8 23 35.72 3.00 32T 7.00 120 1 1.049 0.380 0.650 14.97 10.52 3.80 23 103 17.99 3.00 32T 7.00 120 1 1.049 0.107 -0.867 10.52 10.32 1.07 23 104 17.73 5.00 2T 2.00 120 1 1.049 0.104 -0.217 10.52 10.02 0.72 24 105 19.16 3.50 32T 7.00 120 1 1.049 0.120 -0.217 12.74 11.70 1.26 27 109 18.99 3.50 32T 7.00 120 1 1.049 0.118 -0.217 12.52 11.50 1.24 12 30 31.94 3.00 32T 7.00 120 1 1.049 0.309 0.650 12.06 8.33 3.09 30 112 16.15 3.00 32T 7.00 120 1 1.049 0.087 -0.867 8.33 8.32 0.87 30 113 15.79 5.00 2T 2.00 120 1 1.049 0.084 -0.217 8.33 7.95 0.60 15 35 30.87 3.00 32T 7.00 120 1 1.049 0.290 0.650 11.30 7.75 2.90 35 118 15.63 3.00 32T 7.00 120 1 1.049 0.082 -0.867 7.75 7.79 0.82 35 119 15.24 5.00 2T 2.00 120 1 1.049 0.078 -0.217 7.75 7.40 0.56 36 120 17.49 3.50 32T 7.00 120 1 1.049 0.101 -0.217 10.60 9.76 1.06 39 123 17.47 3.50 32T 7.00 120 1 1.049 0.101 -0.217 10.57 9.73 1.06 18 42 30.35 3.00 32T 7.00 120 1 1.049 0.281 0.650 10.90 7.44 2.81 42 126 15.35 3.00 32T 7.00 120 1 1.049 0.079 -0.867 7.44 7.51 0.79 42 127 15.00 5.00 2T 2.00 120 1 1.049 0.076 -0.217 7.44 7.17 0.48 A MAX. VELOCITY OF 19.41 ft./sec. OCCURS BETWEEN REF. PT. 6 AND 7 Sprinkler-CALC Release 7.2 Win By Walsh Engineering Inc. North Kingstown R.I. U.S.A. flu.----- uII1Iii....__ IIIIIIIIEi,... IIIIlIIuII..----- I.:jpjuju ilIUN 1i BOOM I I .111ç 1!.ii I1.Iu !uIiIi IIc1II:1a1'I'i.j ' I Sprinkler-CALC 7.2 Win Tri County Fire The Silent Fireman - Saves Lives and Property 12221 Poplar St., Unit 1, Hesperia, CA 92344 HYDRAULIC CALCULATIONS COVER SHEET Reedemer by the Sea - Bldg 2 -2nd Floor Rev 1 3-19-09 WATER SUPPLY STATIC PRESSURE (psi) 71 RESIDUAL PRESSURE (psi) 67 RESIDUAL FLOW (gpm) 1185 BOOSTER PUMPS NUMBER OF BOOSTER PUMPS 0 SPRINKLERS MAXIMUM SPACING OF SPRINKLERS (ft) 12.5 MAXIMUM SPACING OF SPRINKLER LINES (ft) 12 SPECIFIED DISCHARGE DENSITY (gpm/sq. ft.) .1 THIS SPRINKLER SYSTEM WILL DELIVER A DENSITY OF .1 gpm/sq. ft. FOR A DESIGN AREA OF 1365 SQ. FT. OF FLOOR AREA THIS SYSTEM OPERATES AT A FLOW OF 228.93 gpm AT A PRESSURE OF 34.01 psi AT THE BASE OF THE RISER (REF. PT. 4) PIPES USED FOR THIS SYSTEM 107 PVC BLUE BRUTE (150) 111 DUCTILE IRON (350) 002 SCHEDULE 10 001 SCHEDULE 40 E&1000&kl2H L1&100E1&}10H Tri County Fire The Silent Fireman - Saves Lives and Property Reedemer by the Sea - Bldg 2 -2nd Floor Rev 1 3-19-09 PAGE 1 HYDRAULIC CALCULATIONS AT SPECIFIED DENSITY THE FOLLOWING SPRINKLERS ARE OPERATING IN: TEST AREA 1 [ I TEST AREA 2 Ii ] TEST AREA 3 <] REMOTE AREA Elevation of sprinklers = Elevation above water test. REF. PT. K ELEV. FLOW PRESSURE ft gpm psi 201 5.60 19.50 20.64 13.58 202 5.60 21.50 17.39 9.64 203 5.60 18.50 19.53 12.16 204 5.60 19.50 20.17 12.97 205 5.60 21.50 16.18 8.35 206 5.60 18.50 18.18 10.54 207 5.60 19.50 20.04 12.80 208 5.60 21.50 15.46 7.62 209 5.60 18.50 17.37 9.62 210 5.60 21.50 15.10 7.27 211 5.60 18.50 16.99 9.20 212 5.60 21.50 15.00 7.17 213 5.60 18.50 16.89 9.09 THE SPRINKLER SYSTEM FLOW IS 228.93 gpm THE OUTSIDE HOSE FLOW AT REFERENCE POINT NO. 1 IS 100.00 gpm THE INSIDE HOSE [ I RACK SPKLR'S. YARD HYDT. FLOW IS 0.00 gpm THE MINIMUM DENSITY PROVIDED BY THIS SYSTEM IS 0.100 gpm/sq. ft. THE FOLLOWING PRESSURES & FLOWS OCCUR ---> AT REF. PT. 1 <--- STATIC PRESSURE 71.00 psi RESIDUAL PRESSURE 67.00 psi AT 1185.00 gpm TOTAL SYSTEM FLOW 328.93 gpm AVAILABLE PRESSURE 70.63 psi AT 328.93 gpm OPERATING PRESSURE 38.87 psi AT 328.93 gpm PRESSURE REMAINING 31.76 psi THE ABOVE RESULTS INCLUDE 5.00 psi FRICTION LOSS AT REF. PT. it 2 FOR A I BACKFLOW PREVENTER [ 1 METER [)K DETECTOR CHECK VALVE [ I OTHER DEVICE E&l0OL&k10H Tri County Fire The Silent Fireman - Saves Lives and Property Reedemer by the Sea - Bldg 2 -2nd Floor Rev 1 3-19-09 PAGE 2 FITTING Equivalent Length per NFPA 13 1994, 6-4.3 '-' Indicates Equivalent Length. 'T' Indicates Threaded Fitting 1=45 Elbow, 2=90 Elbow, 3=!T/Cross, 4=Butterfly Valve, 5=Gate Valve, 6=Swing Check Valve FROM TO FLOW PIPE FITS EQV. H-W PIPE DIA. FRIC. ELEV. FROM TO DIFF (gpm) (ft) (ft) C TYPE (in) (psi) (psi) (psi) (psi) (psi) 1 2 228.93 35.00 35 50.07 150 107 6.090 0.001 0.000 38.87 38.74 0.13 2 3 228.93 10.00 22552 30.59 100 111 6.400 0.002 0.000 38.74 33.64 5.10 3 4 228.93 125.00 21112 60.14 150 107 6.090 0.001 -0.650 33.64 34.01 0.28 4 5 228.93 7.50 224 33.80 120 2 4.260 0.013 3.250 34.01 30.23 0.53 5 6 228.93 28.00 22311 37.78 120 2 3.260 0.047 0.217 30.23 26.91 3.10 6 45 228.93 25.00 22 13.40 120 2 3.260 0.047 0.000 26.91 25.09 1.82 45 46 228.93 12.00 3 17.42 120 2 3.260 0.047 5.200 25.09 18.50 1.39 46 47 228.93 4.50 3 17.42 120 2 3.260 0.047 0.000 18.50 17.46 1.04 47 48 168.09 10.00 0 0.00 120 2 3.260 0.027 0.000 17.46 17.16 0.30 48 49 88.96 10.00 0 0.00 120 2 3.260 0.008 0.000 17.16 17.08 0.08 47 201 60.84 11.25 33T 16.00 120 1 1.610 0.126 0.433 17.46 13.58 3.45 48 202 79.13 14.25 33T 16.00 120 1 1.610 0.206 1.300 17.16 9.64 6.22 49 203 88.96 11.25 3T 8.00 120 1 1.610 0.256 0.000 17.08 12.16 4.92 201 204 40.20 10.00 0 0.00 120 1 1.610 0.059 0.000 13.58 12.97 0.61 202 205 61.74 10.00 0 0.00 120 1 1.610 0.130 0.000 9.64 8.35 1.29 203 206 69.43 10.00 0 0.00 120 1 1.610 0.162 0.000 12.16 10.54 1.62 204 207 20.04 10.00 0 0.00 120 1 1.610 0.016 0.000 12.97 12.80 0.16 205 208 45.56 10.00 0 0.00 120 1 1.610 0.074 0.000 8.35 7.62 0.72 206 209 51.25 10.00 0 0.00 120 1 1.610 0.092 0.000 10.54 9.62 0.92 208 210 30.10 10.00 0 0.00 120 1 1.610 0.034 0.000 7.62 7.27 0.35 209 211 33.87 10.00 0 0.00 120 1 1.610 0.043 0.000 9.62 9.20 0.42 210 212 15.00 10.00 0 0.00 120 1 1.610 0.009 0.000 7.27 7.17 0.10 211 213 16.89 10.00 0 0.00 120 1 1.610 0.012 0.000 9.20 9.09 0.11 A MAX. VELOCITY OF 14.01 ft./sec. OCCURS BETWEEN REF. PT. 49 AND 203 Sprinkler-CALC Release 7.2 Win By Walsh Engineering Inc. North Kingstown R.I. U.S.A. Wf L1IAIiIIII W Eli1III1III..R___ E.T YTiii• ________________________________________________ uIIAIIIuI 1111A111111.. W T111• _____ 1IAI1IIIl.. Of Iil :1 u V 41A111111RR 11A111111..__ I II Ii'I. !lIIIl - Sprinkler-CALC 7.2 Win P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 077 ATTACHMENT FITTING LOCKING WI SIZE - I and 1 1/4 inch bracing pipe. Use in combination with 1 thru 8 inch AFCON sway brace assemblies. MATERIAL - Carbon Steel, Ductile Iron or S.S. (Type 304). FINISH - Plain, E.G. and H.D.G. LISTING/APPROVAL - 203A-EX2625 Listed only for use with other AFCON bracing products. OSHPD OPA-0601 See Website. FUNCTION - Structure attachment fitting of a sway brace assembly, consisting additionally of AFCON 001 thru 040 sway brace fitting and brace element forming a complete sway brace assembly. INSTALLATION - Per NFPA 13 . Listed for use with NFPA 13 fastener tables. For installation on H-beam or steel web joist see AFCON 085 thru 088 sway brace adapters. ASSEMBLY - Insert brace pipe into fitting against the pivot bolt. Tighten set bolt until head contacts bracket. FEATURES * UL Horizontal Load Rating: 2015#, All Sizes * Swivel design allows attachment at any angle. * Visual inspection, proper installation when set bolt head contacts bracket. * 17/32" Fastener hole, larger hole available.- Consult factory. ORDERING - Part #, pipe size and finish. Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER- AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any director indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-AFCON products have been, or are used. 5/08 /Ac!n P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 078 ATTACHMENT FITTING LOCKING STRAIGHT Part #O77-..... SIZE - 1 and 1 1/4 inch bracing pipe. Use in combination with 1 thru 8 inch AFCON sway brace assemblies. MATERIAL - Carbon Steel. FINISH - Plain, E.G. and H.D.G. LISTING/APPROVAL - 203A-EX 2625 Listed only for use with other AFCON bracing products. OSHPD OPA-0601 See Website. FUNCTION - Attachment fitting of a sway brace assembly, consisting additionally of AFCON 001 thru 040 sway brace fitting and brace element forming a complete sway brace assembly. Commonly used as the brace pipe attachment component of a #410 longitudinal sway brace assembly- see drawing INSTALLATION - Per NFPA 13. Listed for use with NFPA 13 fastener tables. Installation restricted to NFPA 13, G-H-I orientation ONLY DO NOT BEND - IF ANGLE REQUIRED USE PART #070, #076 or #077 For installation on H-beam or steel web joist see AFCON 085 thru 088 sway brace adapters. ASSEMBLY -Insert brace pipe into fitting against the pivot bolt . Tighten set bolt until head contacts bracket. FEATURES * UL Horizontal Load Rating: 2015#, All Sizes. * Visual inspection, proper installation when set bolt head contacts bracket. * Bolt hole fits #410 sway brace fitting. ORDERING - Part #, pipe size and finish. Specific AFCON products are exclusively designed to be compatible ONLY with Other AFCONproducts including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-AFCON products have been, or are used. 5/08 9/L6 flu. rt# 078 Fic!n P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 079 4-WAY SWAY BRACE ATTACHMENT SIZE - 1"x 1", 1 1/4°x 1", 1 1/4"x 1 1/4" Use with 1 thru 8 inch AFCON sway brace assemblies. MATERIAL - Carbon Steel. FINISH - Plain, E.G. and H.D.G. LISTING/APPROVAL - 203A-EX 2625 Listed only for use with other AFCON bracing products. OSHPD OPA-060 1 See Website. FUNCTION - 4-way sway brace assembly component for use on risers and other vertical piping configurations. INSTALLATION - Locate at 3" MAXIMUM distance from pipe being braced. Insert brace pipe into fitting against the pivot bolt. Tighten set bolt until head contacts bracket. FEATURES * UL Horizontal Load Rating: 2015#, All Sizes. * Visual inspection, proper installation when set bolt head contacts bracket. ORDERING - Part #, size and finish. Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any director indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-AFCON products have been, or are used. 1/08 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 410 SWAY BRACE FITTING Part # 077....... rt# 078 SIZE - 1 thru 8 inch pipe. MATERIAL - Carbon Steel or S.S. (Type 304). FINISH - Plain, E.G., and H.D.G. LISTING/APPROVAL - c®LJs 203A-EX 2625, 203-EX 2551 Listed only for use with other AFCON bracing products. OSHPD OPA-0601 See Website. FUNCTION - Pipe attachment component of a longitudinal or 4-way sway brace, consisting additionally of AFCON 70 series attachment end, AFCON 80 series adapter as required and brace pipe element forming a complete sway brace assembly. INSTALLATION - Per NFPA 13. Assemble 410 over pipe to be braced, install 70 series attachment end on outside of clamp ears and tighten bolts to minimum required torque of 40 tUbs. 078 is the preferred assembly component for use with the 410 - see drawing. FEATURES * UL Horizontal Load Rating: 1-3 pipe size = 500# 4-8 pipe size = 2015# * Made with 1/2" bolts to conform with sway brace fittings. ORDERING - Part #, pipe size and finish. Specific AFCON products are exclusively designed lobe compatible ONLY with other AFCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-A FCON products have been, or am used. 5.. _5.. ...' 551 cs. P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 310 RING RESTRAINER Restraint SIZE - One size fits 3/4 thru 2 inch AFCON #300 Ring Hanger. MATERIAL - Carbon Steel. FINISH - Mil. Galvanized. LISTINGS - c-us 203-EX 2551 Listed only for use with AFCON #300 Ring Hanger. FUNCTION - To restrain movement of sprinkler pipe toward the knurl nut of the ring hanger. To prevent upward movement of pipe that supplies a pendent sprinkler below the ceiling. INSTALLATION - Per NFPA 13 and CPVC manufacturers instructions on steel, CPVC, or copper pipe. Snap into locking position on swivel nut of AFCON #300 Ring Hanger. SPECIAL NOTE: When installing on CPVC sprinkler system pipe: Verify that all assembly components are cleaned of any surface oil. FEATURES - * Listed only for use with AFCON #300 Ring Hanger. ORDERING - Part # and size. Specific .4FCONproducts are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shalt NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to toss of business or profit, when non-AFCON products have been, or are used. IMPERIAL MAX REC. LOAD LBS. METRIC" PIPE FROD PIPE ROD 1/2 3/8 400 10 3/4 3/8 400 20 10 1 3/8 400 s 10 11/4 3/8 400 :32 10 11/2 3/8 400 40 10 2 3/8 400 50 10 2 1/2 3/8 600 65 to 3 3/8 600 so to 31/2 3/8 600 10 4 3/8 1000 oo 10 5 1/2 1250 125 12 6 1/2 1250 iso 12 8 1250 200 1 2 * Order Part 1300m Note: 1/2" Ring Hanger not <FM> approved % inch pipe S thru 8 inch pipe IAc P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 300 RING HANGER 3/4 thru 4 inch pipe LISTED FOR STEEL/CPVC SIZE - 1/2 thru 8 inch pipe. MATERIAL - Carbon Steel, Mu. Galvanized to G-90 spec. LISTING/APPROVAL - 203-EX 2551 Approval guide - Pipe Hangers OSHPD OPA-060 1 See Website. CONFORMS WITH: Federal Specification WW-H-171 (Type 10, Manufacturers Standardization Society ANSI/MSS-SP-58 (Type 10). MAXIMUM TEMPERATURE - 650°F. FUNCTION - Pipe hanger component for use on steel, CPVC or copper piping. INSTALLATION - Per NFPA 13,13R, 13D and CPVC manufacturers instructions. SPECIAL NOTE: When installing on CPVC sprinkler system pipe: Verify that all assembly components are cleaned of any surface oil. FEATURES - * Sized and listed exclusively for use with #310 Surge Restrainer. * Band edge is offset for EASY pipe insertion. * Custom fit swivel nut for better retention in ring body. * Full length knurl on swivel nut for better grip. ORDERING - Part #, pipe size. P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 552 TAPPED BRACKET SIZE - 3/8' rod. MATERIAL - Carbon Steel. FINISH - Plain, E.G. and H.D.G. - LISTING/APPROVAL - + 203 - EX 2551 I FUNCTION - To support max. 4" horizontal piping - Steel, C.P.V.C. or Copper. 1/2 Hanger assembly component listed for mounting on vertical surface. 4, INSTALLATION -per NFPA 13. Space by pipe type. Install on wood, concrete or steel. Center hole accepts 3/8" and 1/2" NFPA 13 fasteners. Additional UL LISTED fasteners per NFPA 13 for steel pipe loads - see tables. FEATURES * Tapped rod hole. * Double fastener installation allows: Vertical - Hangs plumb from first fastener. Stops wood splitting along the grain. * No speed/pal nuts required. ORDERING - Part # and finish. 553 BRACKET Wood - No Pre Drill Mm. Mm. Max. Fastener Qty. Pipe Steel - 1/4" or #14 Tek Mm. Mm. Max. Thickness Qty. Pipe #14x1 1/2 S.M.S. 1 2 14 GA. 1 3 #14x2S.M.S. 2 4 2 4 1/4x2L.B. 1 21/2 16 GA. 1 2 1/4x2L.B. 2 4 2 3 #16x2D.S. 2 2 18 GA. 2 21/2 WS-Wood Screw D.S. Dtivr Screw S.M.S. Sheet Metol Screw L. B.= Log Bolt SIZE - 3/8" rod MATERIAL - Carbon Steel. FINISH - Plain, E.G. and H.D.G. LISTING/APPROVAL - c®os 203 - EX 2551 NOTE - Criteria same as 552 above except 13/32" rod hole. Install hanger rod with 3/8" nut. 2/07 JcnJ tqCo /Fire & Building / )Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Model BFV-N Butterfly Valve Grooved End 2-1/2 Inch - 10 Inch (DN65 - DN250) General Description The Model BFV-N Grooved End But- terfly Valves (Ref. Figure 1) are indicat- ing type valves designed for use in fire protection systems where a visual in- dication is required as to whether the valve is open or closed. They are used, for example, as system, sectional, and pump water control valves. They have cut groove inlet and outlet connections that are suitable for use with grooved end pipe couplings that are listed and approved for fire protection systems. For applications requiring supervision of the open position of the valve, the Gear Operators for the Model BFV-N Butterfly Valves are provided with two sets of factory installed internal switches each having SPDT contacts. The supervisory switches transfer their electrical contacts when there is move- ment from the valve's normal open po- sition during the first two revolutions of the handwheel. WARNINGS The Model BFV-N Grooved End But- terfly Valves described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authori- ties having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Technical Data Model BFV-N Sizes: ANSI Inches / ON 2-1/2 (DN65), 3 (DN80), 4 (DN100), 5 (DN125), 6 (DN150), 8 (DN200), 10 (DN250) Approvals The 2-1/2 through 10 inch (DN65 - DN250) Model BFV-N Grooved End Butterfly Valves are UL and C-UL List- ed and FM Approved. In addition, the Model BFV-N Grooved End Butterfly Valves are listed by the California State Fire Marshall under Listing No. 7770-1670:100. All laboratory listings and approvals are for indoor and outdoor use. Maximum Working Pressure 2-1/2 - 8 Inch (DN65 - DN200): 300 psi (20,7) bar 10 Inch (DN250): 175 psi (12,0 bar) Materials of Construction; Body Ductile iron conforming to ASTM A-395 Body Coating Polyamide Disc Ductile iron conforming to ASTM A-395 Disc Seal Grade EPDM "E" encapsulated rubber conforming to ASTM D-2000 Upper & Lower Stem Type 416 Stainless Steel conforming to ASTM 582 Lower Plug PVC Operator Gear operator with iron housing Friction Loss The approximate friction loss, based on the Hazen Williams formula and ex- pressed in equivalent length of pipe with C= 120, is as follows. The data is based on friction loss information col- lected at a typical flow rate of 15 feet per second. 6.9 feet of 2-1/2 inch Sch. 40 pipe for the 2-1/2 inch valve. 8.7 feet of 3 inch Sch. 40 pipe for the 3 inch valve. 4.5 feet of 4 inch Sch. 40 pipe for the 4 inch valve. 6.6 feet of 5 inch Sch. 40 pipe for the 5 inch valve. 11.1 feet of 6 inch Sch. 40 pipe for the 6 inch valve. 10.2 feet of 8 inch Sch. 30 pipe for the 8 inch valve. 12.1 feet of 10 inch Sch. 30 pipe for the 10 inch valve. Page 2of4 TFPI5I0 G F HANDWHEEL INDICATOR FLAG 1/2 NPT CNDUIT :: NECTION OPERATOR B (—Zt' FIGURE 1 MODEL BFV-N GROOVED END BUTTERFLY VALVE - NOMINAL DIMENSIONS - Nominal Nominal Installation Dimensions in Inches and (mm) Weight Valve Pipe Sizes O.D. A B C D E F G H 2-1/2' 2.88 3.85 11.71 3.25 5.43 6.00 7.81 2.50 22 0N65 (73,0) (9810) (297,4) (83,0) (137,9) (152,4) (198,4) (63,5) 0 (10,0) 3' 3.50 3.85 12.25 3.54 5.68 6.00 7.81 2.50 23 DN80 (88,9) (98,0) (311,1) (90,0) (144,2) (152,4) (198,4) (63,5) (10,4) 4.50 4.56 13.95 4.35 6.58 6.00 7.81 2.50 28 DN100 (114,3) (116,0) (354,3) (110,0) (167,1) (152,4) (198,4) (63,5) (12,7) 5.56 5.86 14.93 4.84 7.07 6.00 7.81 2.50 0 31 0N125 (141,3) (149,0) (379,2) (123,0) (179,6) (152,4) (198,4) (63,5) (14,1) 6.63 5.86 17.31 5.93 8.35 6.00 7.81 2.50 0.67 41 DN150 (168,3) (149,0) (439,7) (151,0) (212,0) (152,4) (198,4) (63,5) (17,0) (18,6) 8" 8.63 5.26 19.20 6.87 9.29 6.00 7.81 2.50 5.86 53 DN200 (219,1) (134,0) (487,7) (174,0) (236,0) (152,4) (198,4) (63,5) (148,8) (24,1) 10 10.75 6.29 25.11 9.17 11.50 9.00 7.68 3.00 7.41 88 DN250 (273,1) (160,0) (637,8) (233,0) (292,1) (228,6) (195,1) (76,2) (188,2) (40,0) TFPI5IO Page 3 of 4 Installation The Model BFV-N Grooved End But- terfly Valves may be installed with flow in either direction and can be posi- tioned either horizontally or vertically. The grooved end pipe couplings used with the Model BFV-N must be listed or approved for fire protection service and installed in accordance with the manufacturers instructions. The Model BFV-N Butterfly Valve may be installed with any schedule of pres- sure class of pipe or tubing that is list- ed or approved for fire protection. As applicable, refer to Figure 2 for the internal switch wiring diagram. Conduit and electrical connections are to be made in accordance with the authority having jurisdiction and/ or the National Electrical Code. With reference to Figure 2, the "supervi- sory switch" is intended for connec- tion to the supervisory circuit of a fire alarm control panel in accordance with NFPA 72. The "auxiliary switch" is in- tended for the unsupervised connec- tion to auxiliary equipment in accor- dance with NFPA 70, National Electric Code. NOTE For outdoor applications with inter- nal supervisory switches, it is recom- mended that wiring connections be made at a temperature above 15°F (-9°C), in order to insure sufficient flex- ibility of the wire lead insulation. Care and Maintenance The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and devic- es in accordance with the applicable standards of the National Fire Pro- tection Association (e.g., NFPA25), in addition to the standards of any au- thority having jurisdiction. The install- ing contractor or product manufac- turer should be contacted relative to any questions. Any impairment must be immediately corrected. It is recommended that automatic sprinkler systems be inspected, test- ed, and maintained by a qualified in- spection service. SUPERVISORY SWITCH SWITCH SHOWN WITH VALVE _J FULL OPEN W W Cr cc END OF LINE PANEL RESISTOR I— ------ 7 AUXILIARY G / SWITCH I I / SWITCH SHOWN I - WITH VALVE - - FULL OPEN ELL POWER CONTACT RATING 112A @ 125 VDC 1/4A @250 VDC 15.1A112HP @125, 250 VAC 5A@125 VAC 'L FIGURE 2 MODEL BFV-N BUTTERFLY VALVE - INTERNAL SWITCH WIRING DIAGRAM - NOTE Before closing a fire protection system control valve for maintenance or in- spection work on either the valve or fire protection system which it controls, permission to shut down the affected fire protection systems must be ob- tained from the proper authorities and all personnel who may be affected by this decision must be notified. Page 4 of 4 TFPI5IO Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warran- ty is given for products or components manufactured by companies not af- filiated by ownership with TFBP or for products and components which have been subject to misuse, improper in- stallation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protec- tion Association, and/or the standards of any other Authorities Having Juris- diction. Materials found by TFBP to be defective shall be either repaired or re- placed, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other ob- ligation in connection with the sale of products or parts of products. TFBP shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties, ex- press or implied, including warranties of merchantability and fitness for a par- ticular purpose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure Grooved End Butterfly Valves: Specify: (specify inch size) Model BFV-N Grooved End Butterfly Valve with internal supervisory switches, P/N (specify). Valve Size Valve Part Number 2-1/2 ......................59 -300-F-025N 3 .......................... 59-300-F-030N 4 .......................... 59-300-F-040N 5 .......................... 59-300-F-050N 6 .......................... 59-300-F-060N 8 .......................... 59-300-F-080N 10 ......................... 59-300-F-lOON (E)POTTER BELLS The Symbol of Protection PBA-AC & MBA-DC i DL UL, ULC, and FM Approved Sizes Available: 6' (150mm), 8" (200mm) and 10" (250mm) Voltages Available: 24VAC I2OVAC 12VDC (10.2 to 15.6) Polarized 24VDC (20.4 to 31.2) Polarized Service Use: Fire Alarm General Signaling Burglar Alarm Environment: Indoor or outdoor use (See Note 1) -40° to 150°F (-40° to 66°C) (Outdoor use requires weatherproof backbox.) Termination: AC Bells - 4 No. 18 AWG stranded wires DC Bells - Terminal strip Finish: Red powder coating Optional: Model BBK-1 weatherproof backbox Model BBX- I deep weatherproof backbox These vibrating type bells are designed for use as fire, burglar or general signaling devices. They have low power consumption and high decibel ratings. The unit mounts on a standard 4" (101mm) square electrical box for indoor use or on a model BBK-1 weatherproof backbox or BBX-1 deep weatherproof backbox for outdoor applications. Weatherproof backbox model BBK-1, Stock No. 1500001. Notes: Minimum dB ratings are calculated from integrated sound pressure measurements made at Underwriters Laboratories as specified in UL Standard 464. UL temperature range is -301 to 150°F (-34° to 66°C). Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels in an actual installation. ULC only applies to MBA DC bells. Size inches (mm) Voltage Model Number Stock Number Current (Max.) Typical dB at 10 ft (3m) (2) Minimum dB at 10 ft. (3m) (I) 6(150) 12VDC MBA126 1750070 .12A 85 76 8(200) 12VDC MBA128 1750080 .12A 90 77 10 (250) 12VDC MBA1210 1750060 .12A 92 78 6(150) 24VDC rv1BA246 1750100 .06A 87 77 8(200) 24VDC MBA248 1750110 .06A 91 79 10(250) 24VDC MBA2410 1750090 .06A 94 80 6(150) 24VAC PBA246 1806024* .17A 91 78 8 (200) 24VAC PBA248 1808024* .17A 94 77 10 (250) 24VAC PBA2410 1810024* .17A 94 78 6(150) 120VAC PBA1206 1806120* .05A 92 83 8(200) 120VAC PBA1208 1808120* .05A 99 84 10 (250) 120VAC PBA12010 1810120* .05A 99 86 All DC bells are polarized and have built-in transient protection. * Does not have ULC listing. Ak WARNING I In outdoor or wet installations, bell must be mounted with weatherproof backbox, BBK-1 or BBX-1. Standard electrical boxes will not provide a weatherproof enclosure. If the bell and/or assembly is exposed to moisture, it may fail or create an electrical hazard. Potter Electric Signal Company, LLC • 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 888-882-1833. www.pottersignal.com PRINTED IN USA MFG. #5400776 - REV Y PAGE 1 OF 2 5/08 Weatherproof Backbox Dimensions Inches (mm) Fig. 2 Box has one threaded 1/2" conduit entrance 5 3/4" (146) (86) (127) L 33/8" (41) (86) 41/4" (108) DWG# 776-2 (E)POTTER BELLS The Symbol of Protection PBA-AC & MBA-DC Bells Dimensions Inches (mm) Wiring (rear view) Fig. I Fig. 3 10" 6 WHITE (IN) WHITE (OUT) A.C. BELLS (250) FROM COND B PANEL BLACK (OUT) PRECEDING(200) (ISO) CAUTION: 2 11/16" WI1 ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN. -H (68) DWGI 776-I NOTES: WHEN USING AC BELLS, TERMINATE EACH EXTRA WIRE SEPASATELYAFTER LAST SELL. END-OF-LINE RESISTOR IS NOT REQUIRED ON AC BELLS. DWG6 776-3 Installation The bell shall be installed in accordance with NFPA 13, 72, or local AHJ. The top of the device shall be no less than 90" AFF and not less than 6" below the ceiling. Remove the gong. Connect wiring (see Fig. 3). Mount bell mechanism to backbox (bell mechanism must be mounted with the striker pointing down). Reinstall the gong (be sure that the gong positioning pin, in the mechanism housing, is in the hole in the gong). Test all bells for proper operation and observe that they can be heard where required (bells must be heard in all areas as designated by the authority having jurisdiction). A WARNING Failure to install striker down will prevent bell from operating. PR TED IN USA MFG. 45400776 - REV Y PAGE 2 OF 2 5/08 VSR (E)POTTER VANE TYPE WATERFLOW The Symbol of Protection ALARM SWITCH WITH RETARD I àWARNING 1 Installation must be performed by qualified personnel and in accordance with all national and local codes and ordinances. Shock hazard. Disconnect power source before servicing. Serious injury or death could result. Risk of explosion. Not for use in hazardous locations. Serious injury or death could result. General Information The Model VSR is a vane type waterfiow switch for use on wet sprinkler systems. It is UL Listed and FM Approved for use on steel pipe; schedules 10 through 40, sizes 2" thru 8" (50 mm thru 200 mm). LPC approved sizes are 2" thru 8" (50 mm thru 200 mm). See Ordering Information chart. The VSR may also be used as a sectional waterfiow detector on large systems. The VSR contains two single pole, double throw, snap action switches and an adjustable, instantly recycling pneumatic retard. The switches are actuated when a flow of 10 GPM (38 LPM) or more occurs downstream of the device. The flow condition must exist for a period of time necessary to overcome the selected retard period. -Enclosure The VSR switches and retard device are enclosed in a general purpose, die-cast housing. The cover is held in place with two tamper resistant screws which require a special key for removal. A field installable cover tamper switch is available as an option which may be used to indicate unauthorized removal of the cover. See bulletin number 5401103 for installation instructions of this switch. Installation (See Fig. 1) These devices may be mounted on horizontal or vertical pipe. On horizontal pipe they should be installed on the top side of the pipe where they will be accessible. The device should not be installed within 6' (15 cm) of a fitting which changes the direction of the waterfiow or within 24" (60 cm) of a valve or drain. UL, CUL and CSFM Listed, FM Approved, LPCBApproved, For CE Marked (EN12259-5) /VdS Approved model use VSR-EU Service Pressure: 450 PSI (31 BAR) - UL Flow Sensitivity Range for Signal: 4-10 GPM(15-38 LPM) - UL Maximum Surge: 18 FPS (5.5mls) Contact Ratings: Two sets of SPDT (Form C) 10.0Ampsat 125/250VAC 2.0Amps at30VDC Resistive 10 mAmps mm. at 24VDC Conduit Entrances: Two knockouts provided for 1/2' conduit. Individual switch compartments suitable for dissimilar voltages. Environmental Specifications: NEMA 4/IP54 Rated Enclosure suitable for indoor or outdoor use with factory installed gasket and die-cast housing when used with appropriate conduit fitting. Temperature Range: 40°F - 120°F, (4.5°C - 49°C) - UL Non-corrosive sleeve factory installed in saddle. Service Use: Automatic Sprinkler NFPA- 13 One or two family dwelling NFPA-13D Residential occupancy up to four stories NFPA-13R National Fire Alarm Code NFPA-72 Optional: Cover Tamper Switch Kit, stock no. 0090148 Replaceable Components: Retard/Switch Assembly, stock no. 1029030 Note: Do not leave cover off for an extended period of time. Drain the system and drill a hole in the pipe using a hole saw in a slow speed drill. (see Fig. 1) Clean the inside pipe of all growth or other material for a distance equal to the pipe diameter on either side of the hole. Roll the vane so that it may be inserted into the hole; do not bend or crease it. Insert the vane so that the arrow on the saddle points in the direction of the waterfiow. Install the saddle strap and tighten nuts alternately to required torque. (see Fig. 1). The vane must not rub the inside of the pipe or bind in any way. Specifications subject to change without notice. Ordering Information Nominal Pipe Size Model Part Number 2" DN50 VSR-2 1144402 2 1/2" DN65 VSR-2 1/2 1144425 3" DN80 VSR-3 1144403 3 1/2 - VSR-3 1/2 1144435 4" DNlOO VSR-4 1144404 5" - VSR-5 1144405 6" DN150 VSR-6 1144406 8" DN200 VSR-8 1144408 PotterElectrie Signal Company, LLC • 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 888-882-1833. www.pottersignal.com PRINTED IN USA MFG. 95401146 - REV K PAGE 1 OF 3 12/08 Fig. 1 RETARD DOJURTMENT: THE DELAY CAN READJUSTED BY ROTATING THE I I RETARD ADJUITRAENTENOE TROMOTO TOE MAX tIliNG ) I BE SET AT TEE - QMRE.I. PREVENT DO NOT LEAVE COVER DIV FOR EST- PmOO OF ~ TERNATELY USE (2) 5 18 162 ADAPTERS AS SHOWN ABOVE ARROW ON -DU OF W-OW ROLL PADDLE IN OPPOSITE DIRECTION OF WATEREI,OW DIRECTION OF WATER FLOW SOS #114545 (Flowing water activates device in one direction only) Installation Requirements Model Nominal Pipe Size Nominal Pipe O.D. Hole Size U-Bolt Nuts Torque inch mm inch mm inch mm ft-lb n-rn VSR-2 2 DN50 2.375 60.3 125+1251-062 33.0±2.0 20 27 VSR-2 1/2 21/2 2.875 73.0 VSR-2 1/2 21/2 DN65 3.000 76.1 VSR-3 3 DN80 3.500 1 88.9 2.00±125 50.8±2.0 VSR-3 1/2 31/2 4.000 101.6 VSR-.4 4 DNlOQ 4.500 1143 VSR-5 5 5.563 141.3 VSR-6 6 DN150 6.625 168.3 VSR-8 8 DN200 8.625 219.1 Fig. 2 Switch Terminal Connections Clamping Plate Terminal I Ak WARNING An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire become dislodged from under the terminal. Failure to sever the wire may render the device inoperable risking severe property damage and loss of life. I A CAUTION I Waterfiow switches that are monitoring wet pipe sprinkler systems shall not be used as the sole initiating device to discharge AFFF, deluge, or chemical suppression systems. Waterfiow switches used for this application may result in unintended discharges caused by surges, trapped air, or short retard times. Fig. 4 Fig. 5 Break out thin section of cover when wiring both To remove knockouts: Place screwdriver at switches from one conduit entrance, I inside edge of knockouts, not in the center. MFG.#5401146- REV K PAGE 2 OF 3 12/08 (E)POTTER The Symbol of Protection VSR VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD Fig. 3 Typical Electrical Connections NEGATIVE DC OR NEUTRAL AC DSITIVE DC R HOT AC 1LOW ZONE I PANEL Notes: The Model VSRhas two switches, one can be used to operate a central station, proprietary or remote signaling unit, while the other contact is used to operate a local audible or visual annunciator. A condition of LPC Approval of this product is that the electrical entry must be sealed to exclude moisture. For supervised circuits see "Switch Terminal Connections" drawing and caution note (Fig. 2). PRINTED IN USA EWS u-BOLT NUT U-BOLT WASHER PIPE SADDLE PIPE PLASTIC PADDLE U-BOLT NOMINAL PIPE DIA. +445 mm (-F 1-3/4) FOR 01450- DN65 (2- 2. It NOMINAL PIPE DIA. +54,0 mm (+ 2-1/8") FOR DN80 - DN200(3 -8 VSR (E)POTTER VANE TYPE WATERFLOW The Symbol of Protection ALARM SWITCH WITH RETARD Compatible Pipe Model Nominal Pipe Size Nominal Pipe O.D. Pipe Wall Thickness Schedule 10 (UL) Schedule 40 (UL) BS-1387 (LPC) DN (VDS) inch mm inch mm inch mm inch turn inch mm inch mm VSR-2 2 DNSO 2.375 60.3 0.109 2.77 0.154 3.91 0.142 3.6 0.091 2.3 VSR-2 1/2 2 1/2 2.875 73.0 1 0.120 3.05 0.203 5.16 VSR-2 1/2 DN65 3.000 76.1 0.142 3.6 0.102 2.6 VSR-3 3 DNSO 3.500 88.9 0.120 3.05 0.216 5.49 0.157 4.0 0.114 2.9 VSR-3 1/2 3 1/2 4.000 1.01.6 0.120 3.05 0.226 5.74 VSR4 4 DNIOO 4.500 114.3 0.120 3.05 0.237 6.02 0.177 4.5 0.126 13.2 VSR-5 5 1 5.563 141.3 0.134 3.40 0.258 6.55 VSR-6 6 DNISO 6.625 168.3 0.134 3.40 10.280 7.11 0.197 5.0 0.157 4.0 VSR-8 8 DN200 1 8.625 219.1 0.148 3.76 0.322 8.18 0.248 6.3 0.177 4.5 Note: For copper or plastic pipe use Model VSR-CF. Testing The frequency of inspection and testing for the Model VSR and its associated protective monitoring system should be in accordance with applicable NFPA Codes and Standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). If provided, the inspector's test valve, that is usually located at the end of the most remote branch line, should always be used for test purposes. Ifthere are no provisions for testing the operation of the flow detection device on the system, application of the VSR is not recommended or advisable. A minimum flow of 10 GPM (38 LPM) is required to activate this device. Maintenance Inspect detectors monthly for leaks. If leaks are found, replace the detector. The VSR waterfiow switch should provide years of trouble-free service. The retard and switch assembly are easily field replaceable. In the unlikely event that either component does not perform properly, please order replacement retard switch assembly stock #1029030. There is no maintenance required, only periodic testing and inspection. Removal To prevent accidental water damage, all control valves should be shut tight and the system completely drained before waterfiow detectors are removed or replaced. Turn off electrical power to the detector, then disconnect wiring. Loosen nuts and remove U-bolts. Gently lift the saddle far enough to get your fingers under it. With your fingers, roll the vane so it will fit through the hole while continuing to lift the waterfiow detector saddle. Lift detector clear of pipe. Important Notice Please advise the person responsible for testing of the fire protection system that this system must be tested in accordance with the testing instructions. Mounting Dimensions DWG# 1146.6 PRINTED IN USA MPG. #5401146 - REV K PAGE 3 OF 3 12/08 tqCU /Fire & Building I Products Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 Series TY-FRB - 2.8,4.2,5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The Tyco® Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright and Pen- dent Sprinklers described in this data sheet are quick response - standard coverage, decorative 3 mm glass bulb type spray sprinklers designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels, shopping malls, etc. The recessed version of the Series TY-FRB Pendent Sprinkler, where ap- plicable, is intended for use in areas with a finished ceiling. It uses either a two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Es- cutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a two-piece Style 20 (1/2 inch NPT) or Style 30 (3/4 inch NPT) Recessec Escutcheon with 1/4 inch (6,4 mm) of recessed adjust- ment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pen- dent position. The adjustment pro- vided by the Recessed Escutcheon re- duces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. tamed when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level versions of the Series TY-FRB Pendent Sprinklers are detailed in Technical Data Sheet TFP356, and Sprinkler Guards are de- tailed in Technical Data Sheet TFP780 WARNINGS The Series TY-FRB Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Numbers TY1131 - Upright 2.81K, 1/2"NPT TY1231 - Pendent 2.81K, 1/2"NPT TY2131 - Upright 4.21K, 1/2"NPT TY2231 - Pendent 4.21K, 1/2"NPT TY3131 - Upright 561K, 1/2"NPT TY3231 - Pendent 5.6K, 1/2"NPT TY4131 - Upright 8.0K, 3/4"NPT TY4231 - Pendent 8.0K, 314"NPT TY4831- Upright 8.0K, 1/2"NPT TY4931- Pendent 8.0K, 1/2"NPT Page 2 of 10 TFPI7I ESCUTCHEON PLATE SEATING SURFACE 2-1/4" (57,2 mm) 1-9/16" (39,7 mm) 7/16(11,1 mm) STYLE 100r2( NOMINAL RECESSED MAKE-IN ESCUTCHEON Ssu* I DEFLECTOR 6 (11,1 mm) I H 7/16" 1 _5 NOMINAL I MAKE-IN (55,6 mm) : 2-3/16" " 7 1/2" NPT SSP DEFLECTOR * 2-718"(73,omm)DIA. --1 PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression 7 - Bushing orifice seat on frame. Screw FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TYII3I) AND PENDENT (TY1231) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT ESCUTCHEON 7/16" (11,1 mm) PLATE SEATING 1/2" NOMINAL SURFACE MAKE-IN T_ ___T 2-3/16" NPT (55,6 mm) f 1-1/2" (38,11 mm) STYLE 10 or 20 RECESSED ESCUTCHEON DEFLECTOR Ol-< ; 7/16" (11,1mm) 1 NOMINAL I MAKE-IN 2-3/16" WRENCH ______ FLATS 1/2" NPT (55,6 mm) SSP DEFLECTOR I 2-7/8" (73,0 mm) DIA. 6* PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3-Sealing 4 - Bulb 6- Deflector 2 - Button Assembly 5 - Compression Screw * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K-FACTOR, 112 INCH NPT SSU * DEFLECTOR 7/16" 11,1 mm) iOMINAL MAKE-IN 2-3/16" (55,6 mm) 6* 1/2" NPT 6* 1/2" (12,7 mm) NOMINAL MAKE-IN 2-1/4" (57,2 mm) TFPI7I Page 3 of 10 ESCUTCHEON 7/16(11,1 mm) STYLE 10 or 20 PLATE SEATING NOMINAL RECESSED 1/2" SURFACE MAKE-IN ESCUTCHEON NPT 2-3/16 \ (55,6 mm) IFFLATS (38,1mm) SSP DEFLECTOR * 2-7/8" (73,0 mm) DIA. IIi]*Il RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT ESCUTCHEON 1/2" (12,7 mm) PLATE SEATING 3/4', NOMINAL SURFACE MAKE-IN 2-5/16" _ NPT (58,7 mm) 1-9/16" (39,7 mm) I - CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 8.0 K-FACTOR, 314 INCH NPT STYLE 30 or 40 RECESSED ESCUTCHEON SSU* / DEFLECTOR WRENCH FLATS SS DEFLECTOR* 2-7/8" (73,0 mm) DIA. 3/4" NPT PENDENT RECESSED PENDENT UPRIGHT 7/16 (11,1 mm) NOMINAL 1/2 MAKE-IN NPT 2-1/4" (57,2 mm) I 1-9/16" WRENCH I (39,7 mm) FLATS DEFLECTOR PENDENT UPRIGHT CROSS SECTION SSu * DEFLECTOR Page 4 of 10 TFPI7I 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw FIGURE 5 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4831) AND PENDENT (TY4931) SPRINKLERS 8.0 K-FACTOR, 1/2 INCH NPT Technical Data Approvals UL and C-UL Listed. FM, LPCB, and NYC Approved. (Refer to Table A and B for complete approval information including corro- sion resistant status.,) Maximum Working Pressure Refer to Table C. Discharge Coefficient K = 2.8 GPM/p5i112 (40,3 LPM/bar112) K = 4.2 GPM/psil'2 (60,5 LPM/bar1'2) K = 5.6 GPM/psi1l2 (80,6 LPM/bari'2) K = 8.0 GPM/p5i112 (115,2 LPMIbar1I2) Temperature Ratings Refer to Table A and B Finishes Sprinkler: Refer to Table A and B. Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated. Physical Characteristics Frame .............Bronze Button .........Brass/Copper Sealing Assembly .......... Beryllium Nickel w/Teflont Bulb ...............Glass Compression Screw .....Bronze Deflector .......Copper/Bronze Bushing (K=2.8) .......Bronze Operation The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. Design Criteria The Series TY-FRB Pendent and Up- right Sprinklers are intended for fire protection systems designed in ac- cordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Pre- vention Data Sheets ). Only the Style 10, 20, 30, or 40 Recessed Escutch- eon, as applicable, is to be used for recessed pendent installations. -I- TFPI7I SPRINKLER FINISH (See Note 7) K TYPE TEMP. BULB LIQUID NATURAL BRASS I CHROME PLATED I WHITE* IPOLYESTER 2.8 1/2" PENDENT (TY1231) and UPRIGHT (TY1131) 135°F/57°C Orange 1,2,3,5 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141C Blue NPT RECESSED PENDENT (TY1231)* Figure 6 135°F/57°C Orange 1, 2, 5 155F/68°C Red 175°F/79°C Yellow 200F/93°C Green RECESSED PENDENT (TY1231) Figure 7 135°F/57°C Orange 155°F/68°C Red 175°F/79°C Yellow 200°F193°C Green 4.2 1/2" NPT PENDENT (TY2231) and UPRIGHT ('2131) 135°F/57°C Orange 1,2 155°F/68°C Red 175°F/79°C Yellow 200°FI93C Green 286°F/141°C Blue RECESSED PENDENT (TY2231)* Figure 8 135F/57°C Orange 155°F/68°C Red 175°F/79C Yellow 200°F/93"C Green RECESSED PENDENT (TY2231) Figure 9 135°F/57°C Orange 155°F/68C Red 175°F/79°C Yellow 200°F193°C I Green NOTES: Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Re- sponse Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprin- klers. 5. Approved by the City of New York under MEA 354-01-E. 7. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprin- klers are UL and C-UL Listed as Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS 2.8 AND 4.2 K-FACTOR SPRINKLERS Page 5 of 10 Page 6 of 10 TFPI7I SPRINKLER FINISH (See Note 8) K TYPE TEMP. BULB LIQUID NATURAL BRASS I CHROME PLATED I WHITE POLYESTER LEAD COATED 5.6 1/2" PENDENT (TY3231) and UPRIGHT (TY3131) l35F/57°C Orange 1,2,3,4,5,6,7 1,2,3,5 155°F168°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F1141°C Blue NPT RECESSED PENDENT (TY3231)* Figure 10 135°F/57°C Orange 1, 2,4, 5 N/A 155°F/68°C Red 175F/79°C Yellow 200°F/93°C Green RECESSED PENDENT (TY3231 r Figure 11 135°F/57°C Orange 1,2, 3,4, 5 N/A 155°F/68°C Red 175°F/79°C Yellow 200°17/93°C Green 8.0 3/4,, PENDENT (TY4231) and UPRIGHT (TY4131) 135°F/57°C Orange 1,2, 3,4, 5,6, 7 1,2,5 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue NPT RECESSED PENDENT (TY4231)* Figure 12 135F/57°C Green 1, 2,4, 5 N/A 155°F/68°C Orange 175°F/79°C Red 200°F193°C Yellow RECESSED PENDENT (TY4231)** Figure 13 135°F/57°C Orange 1, 2, 3,4, 5 N/A 155°F/68°C Red 175°F179°C Yellow 200°F193°C Green 8.0 1/2" NPT PENDENT (TY4931) and UPRIGHT (TY4831) 135F/57°C Orange 1,2,4, 5,6 1,2,5 155°F/68°C Red 175°F/79°C Yellow 200FI93C Green 286°F/141°C Blue NOTES: Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k104) as Quick Response Sprinklers; however, the LPCB does not rate the thermal sensitivity of recessed sprinklers. Approved by the City of New York under MEA 354-01-E. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377). Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4k Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2' NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS 5.6 AND 8.0 K-FACTOR SPRINKLERS TFPI7I Page 7 of 10 SPRINKLER FINISH K TYPE NATURAL CHROME WHITE LEAD BRASS PLATED POLYESTER I COATED PENDENT (TY3231) and 2.8 UPRIGHT (TY3131) 175 PSI (12,1 BAR) N/A 1/2" RECESSED PENDENT NPT (TY323) PENDENT (1Y4231) and 4.2 UPRIGHT (TY4131) 175 PSI (12,1 BAR) N/A RECESSED PENDENT NPT (TY4231) PENDENT (TY3231) and 250 PSI (17,2 BAR) 175 PSI (12,1 BAR) 5.6 UPRIGHT (1Y3131) OR 1/2" 175 PSI (12,1 BAR) RECESSED PENDENT NPT (TY3231) (SEE NOTE 1) N/A PENDENT (1Y4231) and 175 PSI (12,1 BAR) 175 PSI (12,1 BAR) 8.0 UPRIGHT (TY4131) RECESSED PENDENT NPT (TY4231) N/A 8.0 PENDENT (TY4931) 1/2" and 175 PSI (12,1 BAR) 175 PSI (12,1 BAR) NPT UPRIGHT (1Y4831) NOTES: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL); and , the Approval by the City of New York. TABLE C, MAXIMUM WORKING PRESSURE Installation The Series TY-FRB Sprinklers must be installed in accordance with the fol- lowing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F/57°C to 3/32 inch (2,4 mm) for the 286°F/141°C temperature ratings. A leak tight 1/2 inch NPT sprinkler joint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft. lbs. (28,5 Nm) of torque may be used to install sprinklers with 1/2 NPT connections. A leak fight 3/4 inch NPT sprinkler joint should be ob- tained with a torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). A maximum of 30 ft.lbs. (40,7 Nm) of torque is to be used to install sprinklers with 3/4 NPT con- nections. Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuffi- cient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. The Series TY-FRB Pendent and Up- right Sprinklers must be installed in accordance with the following instruc- tions. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 14). With reference to Figures 1, 2, 3, 4, and 5, the W-Type 6 Sprinkler Wrench is to be applied to the sprinkler wrench flats. The Series TY-FRB Recessed Pen- dent Sprinklers must be installed in accordance with the following instruc- tions. Step A. After installing the Style 10. 20, 30, or 40 Mounting Plate, as appli- cable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprin- kler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 15). With reference to Figure 1, 2, 3, and 4, the W-Type 7 Recessed 2-7/8" DIA. - (73,0 mm) 1/2" (12,7 mm) 2-1/4" DIA. 1/4" (6.4 mm) 71 (57,2 mm) MOUNTING CIL7, (3,2 1 m) 1-5/16" (33,3 mm) 1-111&'(27,0 mm) 1/2±1/8" (12,7±3,2 mm) FACE OF SPRINKLER FITTING T- 7--MOUNTING SURFACE CLOSURE SERIES TY-FRB FIGURE 7 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT - 2-7/8" DIA. 1/2±1/8" (73,0 mm) 1/2" (12,7 mm) r (12,7±3,2 mm) 2-1/4" DIA. I 1/4" (6,4 mm) FACE OF (572mm) MOUNTING I SPRINKLER I PLATE FITTING /8 /1" ///IIIII (3,2 mm) MOUNTING SURFACE SERIES 1-1/4" (31,8 mm) CLOSURE TY-FRB 1" (25,4 mm) FIGURE 9 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT Page 8 of 10 TFPI7I - 2-7/8 DIA. - 5/8±1/4' (73,0 mm) 3/4 (19,1 mm) (15,9±6,4 mm) 2-1/4 DIA. 1/4' (6,4 mm) FACE OF _57,2 mm) MOUNTING SPRINKLER PLATE FITTING 1/8' (3,2 mm) MOUNTING SURFACE/ t CLOSURE SERIES 1-5/16" (33,3 mm)J TY-FRB 13/16'(20,6 mm) FIGURE 6 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. 5/8±1/4" (73,0 mm) 3/4(19,1 mm) (15,9±6,4 mm) 2-1/4" DIA. 1/4" (6,4 mm) FACE OF MOUNTING SPRINKL FITTING ER4R*1 MOUNTIN SURFACE CLOSURE SERIES 1- 1/4 (31,8 mm) TY..FRB 3/4" (19,1 mm) FIGURE 8 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step C. After the ceiling has been in- stalled or the finish coat has been ap- plied, slide on the Style 10, 20, 30, or 40 Closure over the Series TY_FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The Series TY-FRB Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTES Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. The owner must assure that the sprin- klers are not used for hanging of any objects; otherwise, non-operation in the event of a fire or inadvertent opera- tion may result. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been corn- TFP171 - 2-7/8' DIA. 5/8±1/4" (73,0 mm) 3/4" (19,1 mm) - (15,9±6,4 mm) - 2-1/4" DIA. 1/4(6,4 mm) I FACE OF MOUNTING SPRINKLER PLATE SURFACE FITTING _______ 1/8" / MOUNTING CLOSURE SERIES 1-1/4" (31,8 mm) TY-FRB 3/4(19.1 mm) FIGURE 10 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. (73,0 mm) 3/4(19,1 mm) 2-1/4" DIA. 1/4" (6,4 mm) (57,2 mm) MOUNTING FLJkI (3,2 mm) MOUNTING SURFACE CLOSURE SERIES 1-5/16" (33,3 mm) TY-FRB 13/16" (20,6 mm) FIGURE 12 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT Page 9 of 10 2-7/8" DIA. - (73,0 mm) 1/2" (12,7 mm) 2-1/4" DIA. 1/4" (6,4 mm) (57,2 mm) MOUNTING rLt',I I ; 1/8" (32mm) I I 1-1/4" (31,8 mm) 1" (25,4 mm) FIGURE 11 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. 1/2±1/8" (73,0 mm) 1/2" (12,7 mm) (12,7±3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm) FACE OF (57,2 mm) PLATE MOUNTING I SPRINKLER FITTING 13 mm I I \ - _ MOUNTING SURFACE CLOSURE SERIES 1-5/16" (33,3 mm) TY-FRB 1-1/16" (27,0 mm) FIGURE 13 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT 5/8±1/4" (15,9±6,4 mm) FACE OF SPRINKLER FITTING 1/2±1/8° (12,7±3,2 mm) FACE OF SPRINKLER FITTING I \ - MOUNTING SURFACE CLOSURE SERIES pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B" USED FOR 3/4" NPT MODELS) FIGURE 14 W-TYPE 6 SPRINKLER WRENCH facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 15 W-TYPE 7 RECESSED SPRINKLER WRENCH Inspection Service in accordance with local requirements and/or national codes. Page 10 of 10 TFPI7I P/N 57-XXX-X-XXX I I MODEL/SIN I I I 11 1 T 3 9 7 - SPRINKLER NATURAL BRASS WHITE POLYESTER WHITE (RAL9010)* CHROME PLATED 1 LEAD COATED TEMPERATURE _ I RATINGL_. 135 135°F/57°C 155 155°F/68°C 175 175°F/79°C 200 200FI93°C 286 286°F/141°C * Eastern Hemisphere sales only. 330 2.8K UPRIGHT (1/2"NPT) TY1131 331 2.8K PENDENT (1/2"NPT) 1Y1231 340 4.2K UPRIGHT (1/2"NPT) TY2131 341 4.2K PENDENT (1/2"NPT) TY2231 370 5.6K UPRIGHT (1/2"NPT) TY3131 371 5.6K PENDENT (1/2"NPT) TY3231 390 8.0K UPRIGHT (3/4'NPT) TY4131 391 8.0K PENDENT (314"NPT) TY4231 360 8.0K UPRIGHT (1/2"NPT) fl4831* 361 8.0K PENDENT (1/2"NPT) TY4931* TABLED PART NUMBER SELECTION SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. of merchantability and fitness for a Dar- This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure When placing an order, indicate the full product name. Refer to the Price List for complete listing of Part Num- bers. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connections: Specify: (Specify Model/SIN), Quick Response, (specify K-factor), (specify temperature rating), Series TY-FRB (specify Pendent or Upright) Sprinkler with (specify type of finish or coating), P/N (specify from Table D). Recessed Escutcheon: Specify: Style (10, 20, 30, or 40) Re- cessed Escutcheon with (specify*) fin- ish, P/N (specify*). * Refer to Technical Data Sheet TFP770. Sprinkler Wrench: Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. tqCD /Fire & Building / Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Series RFII - 56 K-factor "Royal Flush II" Pendent Concealed Sprinklers Quick & Standard Response, Standard Coverage General Description The Tyco® Series RFll Quick Response (3 mm bulb) & Standard Response (5 mm bulb), 5.6 K-Factor, "Royal Flush II" Concealed Pendent Sprinklers are decorative sprinklers featuring a flat cover plate designed to conceal the sprinkler. It is the best choice for archi- tecturally sensitive areas such as ho- tel lobbies, office buildings, churches, and restaurants. Each unit includes a Cover Plate As- sembly that conceals the sprinkler op- erating components above the ceiling. The separable two-piece design of the Cover Plate and Support Cup Assem- blies allows installation of the sprin- klers and pressure testing of the fire protection system prior to installation of a suspended ceiling or application of the finish coating to a fixed ceiling. They also permit removal of suspend- ed ceiling panels for access to building service equipment without having to first shut down the fire protection sys- tem and remove sprinklers. Also, the separable two-piece design of the Sprinkler provides for 1/2 inch (12,7 mm) of vertical adjustment, to provide a measure of flexibility with re- gard to which the length of fixed pipe drops to the sprinklers must be cut. The Series RFll Sprinklers are shipped with a Disposable Protective Cap. The IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its components and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. Protective Cap is temporarily removed for installation, and then it can be re- placed to help protect the sprinkler while the ceiling is being installed or finished. The tip of the Protective Cap can also be used to mark the center of the ceiling hole into plaster board, ceiling tiles, etc. by gently pushing the ceiling product against the Protec- tive Cap. When the ceiling installation is complete the Protective Cap is re- moved and the Cover Plate Assembly installed. As an option, the Series RFII Standard Response (5 mm bulb) "Royal Flush II" Concealed Pendent Sprinklers may be fitted with a silicone Air and Dust Seal (Ref. Fig. 5). The Air and Dust Seal is intended for sensitive areas where it is desirable to stop air and dust travel through the cover plate from the area above the ceiling. Yi.ii(i1 The Series RFII Concealed Pendent Sprinklers described herein must be installed and maintained in compliance with this document and with the appli- cable standards of the National Fire Protection Association, in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Number TY3551 (5 mm bulb) TY3531 (3 mm bulb) Technical Data Approvals: UL and C-UL Listed. FM Approved NYC under MEA 353-01-E. LPCB (Ref. No. 094a/09 for TY3551 & 094a/10 for TY3531) The approvals apply only to the ser- vice conditions indicated in the De- sign Criteria section. Approvals for Air & Dust Seal: (Part # 10908100) UL and C-UL Listed for use with the RFll (TY3551); Standard Response Concealed Sprinkler. Maximum Working Pressure: Maximum 250 psi (17,3 bar) by UL, C-UL, and NYC. Maximum 175 psi (12,1 bar) by FM and LPCB. Temperature Rating: 155°F/68°C - Sprinkler 1391F/590C - Plate 200°F/93°C - Sprinkler 165°F/74°C - Plate Discharge Coefficient: K= 5.6 GPM/psi1/2 (80,6 LPM/bar1'2) Adjustment: 1/2 inch (12,7 mm) Finishes: Refer to Ordering Procedure section. Page 2 of 4 TFPI8I 1/2 NPT SEALING ASSEMBLY FRAME CAP SUPPORT CUP WITH BULB ROLL FORMED THREADS COMPRESSION SCREW GUIDE - PINS (2) DEFLECTOR (DROPPED DEFLECTOR POSITION) SPRINKLER/SUPPORT CUP ASSEMBLY THREAD INTO II RETAINER SUPPORT CUP ' l WITH THREAD UNTIL MOUNTING 0 0 DIMPLES SURFACE IS FLUSH WITH EJECTION CEILING SPRING SOLDER J 1 COVER TABS (3) COVER PLATE/RETAINER PLATE ASSEMBLY FIGURE 1 MODEL RFII CONCEALED SPRINKLER ASSEMBLY Physical Characteristics: Frame ...................Bronze Support Cup... Chrome Plated Steel Guide Pins .........Stainless Steel Deflector.................Bronze Compression Screw.........Brass Blub ......................Glass Cap.............Bronze or Copper Sealing Assembly................ Beryllium Nickel w/Teflont Cover Plate................Brass Retainer ..................Brass Ejection Spring......Stainless Steel tDuPont Registered Trademark Patents: U.S.A. Patent No. 4,014,388 Operation When exposed to heat from a fire, the Cover Plate, normally soldered to the Retainer at three points, falls away to expose the Sprinkler Assembly. At this point the Deflector supported by the Guide Pins drops down to its operational position. The glass Bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, activating the sprinkler and allowing water to flow. Design Criteria The RFII (TY3551), 5 mm Bulb Type, Concealed Pendent Sprinklers are UL and C-UL Listed as standard response -standard spray sprinklers for use in accordance with the current NFPA standard. They are FM Approved as standard response -standard spray sprinklers for use in accordance with the current FM Loss Prevention Data Sheets. The RFII (TY3531) 3 mm Bulb Type, Concealed Pendent Sprinklers are UL and C-UL Listed as quick response standard spray sprinklers for use in accordance with the current NFPA standard. They are FM Approved as standard response -standard spray sprinklers for use in accordance with the current FM Loss Prevention Data Sheets. The Series RFll Concealed Pendent Sprinklers are only listed and approved with the Series RFII Concealed Cover Plates having a factory applied finish. The Series RFIl must not be used in applications where the air pressure above the ceiling is greater than that below. Down drafts through the Support Cup could delay sprinkler operation in a fire situation. Installation The Tyco® Series RFII must be in- stalled in accordance with the follow- ing instructions: Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 155°F/68°C and 3/32 inch (2,4 mm) for the 200°F/930C temperature ratings. A 1/2 inch NPT sprinkler joint should be obtained with a minimum to max- imum torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). Higher levels of torque may distort the sprinkler inlet with conse- quent leakage or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in the Sprinkler Assembly by under-or over-tightening the Sprinkler/Support Cup Assembly. Readjust the position of the sprinkler fitting to suit. Step 1. The sprinkler must only be in- stalled in the pendent position and with the centerline of the sprinkler per- pendicular to the mounting surface. Step 2. Remove the Protective Cap. Step 3. With pipe thread sealant ap plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 4. Wrench tighten the sprinkler using only the RFll Sprinkler Wrench (Ref. Figure 3). The RFII Sprinkler Wrench is to be applied to the Sprin- kler as shown in Figure 3. Step 5. Replace the Protective Cap (Ref. Figure 4) by pushing it upwards until it bottoms out against the Sup- port Cup. The Protective Cap helps prevent damage to the Deflector and Arms during ceiling installation and/or during application of the finish coating of the ceiling. It may also be used to locate the center of the clearance hole by gently pushing the ceiling material up against the center point of the Pro- tective Cap. EM As long as the Protective Cap remains in place, the system is considered to be "Out of Service". N V MANUFACTURER DEFLECTOR COVER PLATE PRESET GAP IN DROPPED RETAINER 3/32" (2,4 mm) POSITION ASSEMBLY COVER PLATE DIAMETER DIMENSION A 3/16" to 11/16" (4,8 to 17,5 mm) REFERENCE COVER PLATE PROFILE DEPTH DIMENSION B 3-1/4 inches 82,6 mm) C: 2-3/8 to 2-5/8 inches (60,3 to 66,7 mm) 3/16 inches (4,8 mm) 0: 1-3/4 to 2-1/4 inches (44,5 to 57,2 mm) FIGURE 2 SERIES CONCEALED SPRINKLER INSTALLATION DIMENSIONS TFPI8I Page 3 of 4 FACE OF SPRINKLER FITTING SPRINKLER SUPPORT CUP ASSEMBLY 1/2(12,7mm) THREADED D ADJUSTMENT FACE OF CEILING, RETAINING RING MOUNTING SURFACE CLEARANCE HOLE - DIAMETER DIMENSION TT/R-d Step 6. After the ceiling has been completed with the 2-1/2 inch (63,5 mm) diameter clearance hole and in preparation for installing the Cover Plate Assembly, remove and discard the Protective Cap, and verify that the Deflector moves up and down freely. If the Sprinkler has been damaged and the Deflector does not move up and down freely, replace the entire Sprin- kler assembly. Do not attempt to mod- ify or repair a damaged sprinkler. Step 7. When installing an Air and Dust Seal, refer to Figure 5, otherwise proceed to Step 8. To attach the Air and Dust Seal, verify the angle of the outside edge of the seal is oriented ac- cording to Figure 5. Start the edge of the Retainer in the grooved slot of the Air and Dust Seal and continue around the retainer until the entire Air and Dust Seal is engaged. Step 8. Screw on the Cover Plate/Re- tainer Assembly until the Retainer Fig- ure 2 (or Air and Dust Seal -Figure 5) contacts with the ceiling. Do not con- tinue to screw on the Cover Plate/Re- tainer Assembly such that it lifts a ceil- ing panel out of its normal position. If the Cover Plate/Retainer Assembly cannot be engaged with the Support Cup or the Cover Plate/Retainer As- sembly cannot be engaged sufficiently to contact the ceiling, the Sprinkler Fit- ting must be repositioned. Care and Maintenance The Tyco® Series RFll must be maintained and serviced in accordance with the following instructions: Absence of the Cover Plate Assembly may delay sprinkler operation in a fire situation. When properly installed, there is a nom- inal 3/32 inch (2,4 mm) air gap between the lip of the Cover Plate and the ceiling, Page 4 of 4 TFPI8I SUPPORT SPRINKLER FACE OF ORIENT CUP CEILING SEAL BEVEL AS SHOWN COVER PLATE RETAINER ASSEMBLY CLEAN ROOM LIP OF COVER SEAL RETAINER PLATE FIGURE 5 OPTIONAL AIR AND DUST SEAL FOR SERIES RFII (TY3551) as shown in Figure 2. This air gap is necessary for proper operation of the sprinkler. If the ceiling is to be repaint- ed after the installation of the Sprinkler, care must be exercised to ensure that the new paint does NOT seal off any of the air gap. Factory painted Cover Plates MUST NOT be repainted. They should be re- placed, if necessary, by factory painted units. Non-factory applied paint may adversely delay or prevent sprinkler operation in the event of a fire. Do not pull the Cover Plate relative to the Enclosure. Separation may result. Before closing a fire protection sys- tem main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied or over heated sprinklers must be replaced. Care must be exercised to avoid dam- age to the sprinklers -before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). If a sprinkler must be removed, do not reinstall it or a replacement without reinstalling the Cover Plate Assembly. If a Cover Plate Assembly becomes dislodged during service, replace it immediately. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and devic- es in compliance with this document, as well as with the applicable stan- dards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any other authori- ties having jurisdiction. The installing contractor or sprinkler manufacturer should be contacted relative to any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national code. Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warran- ty is given for products or components manufactured by companies not af- filiated by ownership with TFBP or for products and components which have been subject to misuse, improper in- stallation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protec- tion Association, and/or the standards of any other Authorities Having Juris- diction. Materials found by TFBP to be defective shall be either repaired or re- placed, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other ob- ligation in connection with the sale of products or parts of products. TFBP shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties, ex- press or implied, including warranties of merchantability and fitness for a particular purpose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure When placing an order, indicate the full product name. Contact your local distributor for availability. Sprinkler Assembly Specify: (SIN), (specify temperature rating) Series RFII Concealed Pendent Sprinkler, P/N (specify). 155'E168°C 200eF/930C TY3551 51-790-1-155 51-790-1-200 TY3531 51-792-1-155 51-792-1-200 Separately Ordered Cover Plate: Specify: (specify temperature rating) Series RFII Concealed Cover Plate with (specify finish), P/N (specify). 139F/59°C(a) 165°F/74°C(b) Brass..........56-792-1-135 56-792-1-165 Chrome........56-792-9-135 56-792-9-165 Signal White (c) (RAL 9003)... 56-792-4-135 56-792-4-165 Grey White (d) (RAL 9002) 56-792-0-135 56-792-0-165 Pure White (e) (RAL 9010)... 56-792-3-135 56-792-3-165 Custom ........56-792-X-135 56-792-x-165 For use with 155°F/68C sprinklers. For use with 200F/93°C sprinklers. Previously known as Bright White. Previously known as Standard White. Eastern Hemisphere sales only. Sprinkler Wrench: Specify: RFII Sprinkler Wrench, P/N 56-000-1-075. Air and Dust Seal: Specify: Air and Dust Seal, P/N 56-908-1-001. tqCU Fire & Building IPro du c ts Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Series TY-FRB - 28, 4.2, 5. 6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The Tyco® Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright and Pen- dent Sprinklers described in this data sheet are quick response - standard coverage, decorative 3 mm glass bulb type spray sprinklers designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels, shopping malls, etc. The recessed version of the Series TY-FRB Pendent Sprinkler, where ap- plicable, is intended for use in areas with a finished ceiling. It uses either a two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Es- cutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a two-piece Style 20 (112 inch NPT)or Style 30(3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjust- ment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pen- dent position. The adjustment pro- vided by the Recessed Escutcheon re- duces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. tamed when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level versions of the Series TY-FRB Pendent Sprinklers are detailed in Technical Data Sheet TFP356, and Sprinkler Guards are de- tailed in Technical Data Sheet TFP780 WARNINGS The Series TY-FRB Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Numbers TYII3I - Upright 2.8K, 1/2"NPT TY1231 - Pendent 2.8K, 1/2"NPT TY2131 - Upright 4.2K, 1/2"NPT TY2231 - Pendent 4.2K, 1/2"NPT 1Y3131 - Upright 5.6K, 1/2"NPT TY3231 - Pendent 5.6K, 1/2"NPT TY4131 - Upright 8.0K, 3/4"NPT TY4231 - Pendent 8.0K, 3/4"NPT TY4831- Upright 8.0K, 1/2"NPT TY4931- Pendent 8.0K, 1/2"NPT SSU * DEFLECTOR 1/2" NPT UPRIGHT CROSS SECTION 7/16" 11,1 mm) JOMINAL MAKE-IN 2-3/16" (55,6 mm) 6* * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. Page 2 of 10 TFPI7I ESCUTCHEON PLATE SEATING SURFACE 2-1/4" _______ (57,2 mm) 1-9116" (39,7 mm) 1/2" NPT 7/16(11,1 mm) STYLE 10 or 20 NOMINAL RECESSED ss MAKE-IN ESCUTCHEON DEFLECTOR 7/16" (11,1mm) I 1 NOMINAL I MAKE-IN 2-3/16" WRENCH (55,6 mm) FLATS 1/2" NPT SSP DEFLECTOR* H- 2-7/8" (73,0 mm) DIA. PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector 2 - Button Assembly 5 - Compression 7 - Bushing Screw * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TYII3I) AND PENDENT (TY1231) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT ESCUTCHEON 7/16"(11,1 mm) STYLE 10or20 PLATE SEATING 1/2" NOMINAL RECESSED SURFACE NPT MAKE-IN ESCUTCHEON -r— __T 2-3/16" (55,6 mm) _____________ SSPDEFLECTOR* / 1-1/2" WREN( (38,11 mm) içjJl FLATS 2-7/8" (73,0 mm) DIA. PENDENT RECESSED PENDENT 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector 2 - Button Assembly 5- Compression Screw FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K-FACTOR, 112 INCH NPT 1/2" (12,7 mm) NOMINAL MAKE-IN I 2-1/4" (5712 mm) iI CROSS SECTION TFPI7I Page 3of 10 ESCUTCHEON 7/16"(11,1 mm) STYLE 10 or 20 PLATE SEATING ,, NOMINAL RECESSED SSU* SURFACE T MAKE-IN ESCUTCHEON DEFLECTOR (55,6 mm) NOMINAL 4 NOMIr M MAKE (38,1 mm) WRENCH FLATS 3 SSP DEFLECTOR* 2-7/8"(73,0 mm) DIA. 1/2" NPT PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT ESCUTCHEON 1/2' (12,7 mm) PLATE SEATING 3/4', NOMINAL SURFACE MAKE-IN 2-5/16" _ NPT (58,7 mm) W I 1-9/16" (39,7 mm) STYLE 30 or 40 RECESSED SSU* ESCUTCHEON DEFLECTOR 6* WRENCH FLATS SSP DEFLECTOR * f---- 2-7/8" (73,0 mm) DIA. 3/4" NPT PENDENT RECESSED PENDENT UPRIGHT 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 8.0 K-FACTOR, 314 INCH NPT III CROSS UPRIGHT SECTION WRENCH FLATS DEFLECTOR 1— Page 4 of 10 TFPI7I 7/16" (11,1 mm) NOMINAL SSU MAKE-IN DEFLECTOR 1/2' NPT 2-1/4" (57,2 mm) 1-9/16' (39,7 mm) = PENDENT 1 - Frame 3-Sealing 4 - Bulb 6 - Deflector 2 - Button Assembly 5 - Compression Screw * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. FIGURE 5 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4831) AND PENDENT (TY4931) SPRINKLERS 8.0 K-FACTOR, 1/2 INCH NPT Technical Data Approvals UL and C-UL Listed. FM, LPCB, and NYC Approved. (Refer to Table A and B for complete approval information including corro- sion resistant status.) Maximum Working Pressure Refer to Table C. Discharge Coefficient K = 2.8 GPM/psill2 (40,3 LPM/bar1/2) K = 4.2 GPM/p5i1/2 (60,5 LPM/bar1l2) K = 5.6 GPM/psi112 (80,6 LPM/bar1'2) K = 8.0 GPM/psi112 (115,2 LPM/bari'2) Temperature Ratings Refer to Table A and B Finishes Sprinkler: Refer to Table A and B. Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated. Physical Characteristics Frame .............Bronze Button .........Brass/Copper Sealing Assembly .......... Beryllium Nickel w/Teflont Bulb ...............Glass Compression Screw .....Bronze Deflector .......Copper/Bronze Bushing (K=2.8) .......Bronze Operation The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. Design Criteria The Series TY-FRB Pendent and Up- right Sprinklers are intended for fire protection systems designed in ac- cordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Pre- vention Data Sheets ). Only the Style 10, 20, 30, or 40 Recessed Escutch- eon, as applicable, is to be used for recessed pendent installations. Page 5 of 10 TFPI7I SPRINKLER FINISH (See Note 7) K TYPE TEMP. BULB LIQUID NATURAL BRASS I CHROME PLATED I WHITE IPOLYESTER 2.8 PENDENT (TY1231) and UPRIGHT (TY1131) 135°F/57°C Orange 1,2,3,5 155°F/68°C Red 175F/79°C Yellow 200°F193°C Green 286°F1141°C Blue 1/2" NPT RECESSED PENDENT (TY1231)* Figure 6 135FI57°C Orange 1, 2, 5 155°F/68'C Red 175°F/79°C Yellow 200°F/93°C Green RECESSED PENDENT (TY1231) Figure 7 135F/57°C Orange 155F/68°C Red 175°F/79C Yellow 200°F/93°C Green 4.2 1/2" NPT PENDENT (TY2231) and UPRIGHT (1"v'2131) 135°F/57C Orange 1,2 155°F/68'C Red 175°F/79°C Yellow 200F/93°C Green 286°F/141°C Blue RECESSED PENDENT (TY2231)* Figure 8 135°F157°C Orange 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green RECESSED PENDENT (TY2231) Figure 9 135°F/57C Orange 155°F/68°C Red 175°F/79°C Yellow 200F/93C Green NOTES: Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Re- sponse Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprin- klers. 5. Approved by the City of New York under MEA 354-01-E. 7. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprin- klers are UL and C-UL Listed as Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS 2.8 AND 4.2 K-FACTOR SPRINKLERS Page 6 of 10 TFPI7I SPRINKLER FINISH (See Note 8) K TYPE TEMP. BULB LIQUID NATURAL BRASS I CHROME f PLATED I WHITE f POLYESTER LEAD COATED 5.6 1/2" PENDENT (TY3231) and UPRIGHT (TY3131) 135F/57°C Orange 1,2,3,4,5,6,7 1,2,3,5 155°F/68°C Red 175°F/79°C Yellow 200°FI93C Green 286°F/141°C Blue NPT RECESSED PENDENT (TY3231)* Figure 10 135°F/57°C Orange 1, 2,4, 5 N/A 155F/68°C Red 175°F/79°C Yellow 200°F193°C Green RECESSED PENDENT (TY3231) Figure 11 135°F/57°C Orange 1, 2, 3,4, 5 N/A 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 8.0 3/4,, PENDENT (TY4231) and UPRIGHT (TY4131) 135°F/57C Orange 1,2, 3,4, 5,6,7 1,2,5 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue NPT RECESSED PENDENT (TY4231)* Figure 12 135°F/57°C Green 1,2,4,5 N/A 155F/68°C Orange 175°F/79°C Red 200°F/93C Yellow RECESSED PENDENT (TY4231) Figure 13 135°F/57C Orange 1, 2, 3,4, 5 N/A 155°F/68°C Red 175°F/79C Yellow 200F/93°C Green 8.0 1/2" NPT PENDENT (TY4931) and UPRIGHT (TY4831) 135°F/57°C Orange 1,2,4, 5, 6 1,2,5 155°F168°C Red 175°F/79°C Yellow 200F/93C Green 286°F/141C Blue NOTES: Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers; however, the LPCB does not rate the thermal sensitivity of recessed sprinklers. Approved by the City of New York under MEA 354-01-E. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377). Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2' NPT) or Style 40 (3/4' NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2° NPT) or Style 30 (3/4' NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS 5.6 AND 8.0 K-FACTOR SPRINKLERS TFPI7I Page 7 of 10 SPRINKLER FINISH K TYPE NATURAL CHROME WHITE LEAD BRASS PLATED I I POLYESTER COATED PENDENT (TY3231) and 2.8 UPRIGHT (TY3131) 175 PSI (12,1 BAR) N/A 1/2° RECESSED PENDENT NPT (TY323) PENDENT (TY4231) and 4.2 UPRIGHT (TY4131) 175 PSI (12,1 BAR) N/A RECESSED PENDENT NPT (TY4231) PENDENT (TY3231) and 250 PSI (17,2 BAR) 175 PSI (12,1 BAR) 5.6 UPRIGHT (TY3131) OR 1/2° 175 PSI (12,1 BAR) RECESSED PENDENT NPT (TY3231) (SEE NOTE 1) N/A PENDENT (TY4231) and 175 PSI (12,1 BAR) 175 PSI (12,1 BAR) 8.0 UPRIGHT (1Y4131) RECESSED PENDENT NPT (TY4231) N/A 8.0 PENDENT (TY4931) 1/2" and 175P51(12,1 BAR) 175P51(12,1 BAR) NPT UPRIGHT (TY4831) NOTES: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL); and , the Approval by the City of New York. TABLE C, MAXIMUM WORKING PRESSURE Installation The Series TY-FRB Sprinklers must be installed in accordance with the fol- lowing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F/57°C to 3/32 inch (2,4 mm) for the 286°F/141°C temperature ratings. A leak tight 1/2 inch NPT sprinklerjoint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft. lbs. (28,5 Nm) of torque may be used to install sprinklers with 1/2 NPT connections. A leak tight 3/4 inch NPT sprinkler joint should be ob- tained with a torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). A maximum of 30 ft.lbs. (40,7 Nm) of torque is to be used to install sprinklers with 3/4 NPT con- nections. Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuffi- cient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. The Series TY-FRB Pendent and Up- right Sprinklers must be installed in accordance with the following instruc- tions. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 14). With reference to Figures 1, 2, 3, 4, and 5, the W-Type 6 Sprinkler Wrench is to be applied to the sprinkler wrench flats. The Series TY-FRB Recessed Pen- dent Sprinklers must be installed in accordance with the following instruc- tions. Step A. After installing the Style 10. 20, 30, or 40 Mounting Plate, as appli- cable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprin- kler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 15). With reference to Figure 1, 2, 3, and 4, the W-Type 7 Recessed Page 8 of 10 - 2-718' DIA. - 5/8±1/4" (73,0 mm) 3/4" (19,1 mm) (15,9±6,4 mm) 2-1/4" DIA. I 114" (6,4 mm) 1 I I I FACE OF L_S7,2mm) -•I MOUNTING SPRINKLER PLATE - 1/8" FITTING I - (3,2 mm) MOUNTING SURFACE/ t t CLOSURE SERIES 1-5/16" (33,3 mm)f TY-FRB 13/16" (20,6 mm) FIGURE 6 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT - 2-7/8" DIA. - 5/8±1/4" (73,0 mm) 3/4" (19,1 mm) (15,9±6,4 mm) MOUNTING PLATE SPRINKLER FACE OF 2-1/4" DIA. 114" (6,4 mm) 2 mm 1/8" FITTING I ___________________ (3,2 mm) MOUNTING SURFACE SERIES / 1-1/4" (31,8 mm) CLOSURE TY-FRB 3/4" (19,1 mm) FIGURE 8 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT TFPI7I - 2-7/8" DIA. 1/2±1/8" (73,0 mm) 1/2(12,7mm) r (12,7±3,2 mm) 2-1/4" DIA. I 1/4" (6,4 mm) I FACE OF [572 mm) 7-1 MOUNTING I SPRINKLER PLATE I FITTING I 1/8" I (32mm) MOUNTING / SURFACE ,, // CLOSURE SERIES (33,3mm)[ TY-FRB 1-1/16" (27,0 mm) FIGURE 7 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. - (73,0 mm) 1/2" (12,7 mm) 2-1/4" DIA. 1/4" (6,4 mm) (57,2 mm) MOUNTING P CU77 7, m) CLOSURE SERIES 1-1/4" (31,8 mm) 1" (25,4 mm) FIGURE 9 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT 1/2±1/8" (12,7±3,2 mm) FACE OF SPRINKLER FITTING I \ MOUNTING SURFACE Sprinkler Wrench is to be applied to the sprinkler wrench fiats. Step C. After the ceiling has been in- stalled or the finish coat has been ap- plied, slide on the Style 10, 20, 30, or 40 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The Series TY-FRB Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTES Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shutdown the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. The owner must assure that the sprin- klers are not used for hanging of any objects; otherwise, non-operation in the event of a fire or inadvertent opera- tion may result. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been corn- 1 \ - MOUNTING SURFACE CLOSURE SERIES TV-FRB 1/2±1/8" (12,7±3,2 mm) FACE OF SPRINKLER FITTING 2-7/8" DIA. (73,0 mm) 1/2" (12,7 mm) 2-1/4" DIA. 1/4(6,4 mm) I (57,2 mm) MOUNTING / 1 ILfrI 1/8" (3,2 mm) I 1 t 1-5/16" (33,3 mm) 1-1/16" (27,0 mm) 2-7/8" DIA. - (73,0 mm) 3/4" (19,1 mm) 2-1/4" DIA. 1/4(6,4 mm) I (57,2 mm) T1 MOUNTING rLnl (3,2 mm) 1-5/16" (33,3 mm) 13/16" (20,6 mm) 5/8±1/4" (15,9±6,4 mm) FACE OF SPRINKLER FITTING MOUNTING SURFACE CLOSURE SERIES TY-FRB TFPI7I - 2-7/8" DIA. - 518±1/4" (73,0 mm) 314" (19,1 mm) (15,9±6,4 mm) - 2-1/4" DIA. 1/4" (6,4 mm) FACE OF mm) MOUNTING SPRINKLER PLATE FITTING 1/8" (3,2 mm) ___ MOUNTING SURFACE/ SERIES 1-1/4" (31,8 mm) I CLOSURE TV-FRB 3/4"(19,1 mm) FIGURE 10 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT Page 9 of 10 - 2-7/8" DIA. - 1/2±1/8" I (73,0 mm) 1/2"(12,7mm) E (12,7±3,2 mm) 2-1/4" DIA. 1/4(6,4 mm) I SPRINKLEqR PLATE FACE OFi572mm) MOUNTING I I FITTING 1/8 MOUNTIN SURFACESERIES 1-1/4"(31,8mm) CLOSURE 1YFRB 1" (25,4 mm) FIGURE 11 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT FIGURE 12 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT FIGURE 13 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B" USED FOR 3/4" NPT MODELS) FIGURE 14 W-TYPE 6 SPRINKLER WRENCH facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 15 W-TYPE 7 RECESSED SPRINKLER WRENCH Inspection Service in accordance with local requirements and/or national codes. Page lOoflO TFPI7I P/N 57-XXX-X-XXX I MODEUSIN I j_ 1 4 T 9 7 TY4131 SPRINKLER NATURAL BRASS WHITE POLYESTER WHITE (RAL9010)* CHROME PLATED LEAD COATED I RATING 135 135°F/57°C 155 155°F/68C 175 175°Fi79C 200 200°F/93°C 286 286°F/141°C - _________ * Eastern Hemisphere sales only. 330 2.8K UPRIGHT (1/2"NPT) TY1131 331 2.8K PENDENT (1/2"NPT) TY1231 340 4.2K UPRIGHT (112°NPT) TY2131 341 4.2K PENDENT (1/2"NPT) TY2231 370 5.6K UPRIGHT (1/2°NPT) TY3131 371 5.6K PENDENT (1/2"NPT) TY3231 390 8.OK UPRIGHT (3/4"NPT) 391 6.0K PENDENT (314°NPT) TY4231 360 8.0K UPRIGHT (1/2"NPT) TY4831* 361 8.0K PENDENT (1/2"NPT) TY4931* TABLED PART NUMBER SELECTION SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which have been subject to misuse, improper installation, corrosron, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. of merchantability and fitness for a par- ticular purpose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure When placing an order, indicate the full product name. Refer to the Price List for complete listing of Part Num- bers. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connections: Specify: (Specify Model/SIN), Quick Response, (specify K-factor), (specify temperature rating), Series TY-FRB (specify Pendent or Upright) Sprinkler with (specify type of finish or coating), P/N (specify from Table D). Recessed Escutcheon: Specify: Style (10, 20, 30, or 40) Re- cessed Escutcheon with (specify*) fin- ish, P/N (specify*). * Refer to Technical Data Sheet TFP770. Sprinkler Wrench: Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 001/020 SWAY BRACE FITTING - MODEL E Part #077 SIZE - Sprinkler systems pipe: 1" thru 8" Steel Schedule 7 thru 40. SIZE - Sway brace assembly pipe: Steel 1" or 1 1/4" Schedule 40. MATERIAL - Carbon Steel or S.S. (Type 304). FINISH - Plain, E.G., and H.D.G. LISTING/APPROVAL - e(gur, 203A-EX 2625 Listed only for use with other AFCON bracing products. OSHPD OPA-060 1 See Website. PATENT - No. 3,570,794 FUNCTION - Per NFPA 13. Sway brace fitting of a lateral sway brace assembly. To form a 4-way brace on vertical piping, arrange adjacent lateral sway braces. INSTALLATION - Per NFPA 13. Place Model E over pipe to be braced. Insert brace pipe through MODEL "E" under channel bracket, leaving 1" minimum extension beyond. Tighten hex nuts until gage spring lays flat or torque to 65 in.-lbs. ASSEMBLY - Per NFPA 13. Combine with AFCON 70 series structure sway brace fitting and pipe brace element forming a complete sway brace. FEATURES * UL Horizontal Load Ratings for all sizes Sch. 10 thru 40 = 2015# * UL Horizontal Load Ratings for 1" thru 4" Sch. 7 = 655# * UL Horizontal Load Ratings for 6" Sch. 7 = 1500# * Visual inspection, proper installation when gage spring lays flat. ORDERING - Part #, pipe size to be braced, brace pipe size and finish. Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-AFCON products have been, or are used. 1/08 FEATURES SPECIFICATION SUBMITTAL SHEET APPLICATION Designed for installation on potable water connections in fire sprinkler systems to protect against both backsiphonage and backpressure of polluted water into the potable water supply. Model 350DA shall provide protection where a potential health hazard does not exist. Incorporates metered by-pass to detect leaks and unauthorized water use. STANDARDS COMPLIANCE (Sizes 2 1/2"-1 0• Horiz. & Vert.) (12" Horizontal Only) Sizes: U2 1/2" U 3" U 4" U 6" U 8" U10"U 12" • ASSE® Listed 1048 (Sizes 2 1/2" thru 12") Maximum working water pressure 175 PSI Maximum working water temperature 140°F Hydrostatic test pressure 350 PSI End connections (Grooved for steel) AWWA C606 (Flanged) ANSI 1316.1 Class 125 OPTIONS (suffixes can be combined) U - with OS & Y gate valves (standard) U L - less shut-off valves (flanged body connections) U LM - less water meter U - with remote reading meter U - with gpm meter (standard) U CFM - with cu ft/min meter U G - with groove end gate valves U FG - with flanged inlet gate connection and grooved outlet gate connection U P1 - with Post Indicator Gate Valve (3"-10") CSA® Certified B64.5 (Sizes 2 1/2" thru 8") AWWA Compliant C510 (Sizes 2 1/2" thru 12") UL® Classified (Sizes 2 1/2" thru 12") C-UL® Classified (Sizes 2 1/2" thru 12") FM® Approved (Sizes 2 1/2" thru 10") NYC MEA 147-99-M Vol 4 (2-1/2" - 10) Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California (Sizes 2 1/2" thru 10") MATERIALS Main valve body Ductile Iron ASTM A 536 Grade 4 Access covers Ductile Iron ASTM A 536 Grade 4 Coatings FDA Approved fusion epoxy finish Internals Stainless steel. 300 Series ACCESSORIES U Repair kit (rubber only) U Thermal expansion tank (Model XT) U OS & Y Gate valve tamper switch (OSY-40) U Test Cock Lock (Model TCL24) Fasteners Elastomers Polymers Springs NORYLTM, NSF Listed Stainless Steel, 300 Series EPDM (FDA approved) Buna Nitrile (FDA approved) NORYLTM, NSF Listed Stainless Steel, 300 Series Attention: Model 350DA (flange body) and Model 350ADA (grooved body) have different lay lengths. DIMENSIONS & WEIGHTS (do not include pkg.) MODEL 350DAG SHOWN ABOVE MODEL DIMENSION (approximate) WEIGHT 350DA SIZE in. mm _________ A in. mm _________ B LESS GATE VALVES in. I mm C in. I mm D in. I mm E OS&Y OPEN in. mm E OS&Y CLOSED in. I mm F in. I mm G in. I mm WITHOUT GATES VALVES lbs. kg WITH OS&Y GATE VALVES lbs. kg 21/2 65 31 787 157/8 403 33/41 95 9 229 163/8 416 137/8 352 31/2 89 7 1/4 184 68 30.9 178 80.8 3 80 1 32 813 157/8 403 33/41 95 9 229 187/8 479 155/8 397 31/2 89 71/4 184 68 30.9 198 90 4 100 375/8 956 191/2 495 41/2 114 9 229 223/4 578 181/4 464 6 152 8 203 106 48 296 134.4 6 150 443/4 1137 231/2 597 51/2 140 101/2 267 301/8 765 233/4 603 7 178 10 254 180 81.7 480 217.9 8 200 603/4 1543 373/4 959 10 254 12 305 373/4 959 291/4 743 81/2 216 11 279 374 170 850 385.9 10 250 633/41 1619 373/4 959 10 254 12 305 45 3/4 1162 353/8 899 81/2 216 11 279 404 183 1222 554.8 12 300 661/41 1683 1 38 965 10 254 12 305 53 1/811349140 5/8 1032 87/8 226 11 279 463 210 1623 736.2 Page 1 of 2 WILKINS a Zurn company, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805/238-7100 Fax:805/238-5766 In ('nrI 71IPN IldflhISTPIF I IMITPfl 44 Ihahiui flr Mii,iin flnthrir, I 4V 11 9 yQflcIgflc12Q FLOW CHARACTERISTICS MODEL 350DA 21/2",3" & 4" (STANDARD & METRIC) FLOW RATES (us) 0.0 12.6 25.2 37.9 0 200 400 600 FLOW RATES (GPM) MODEL 350DA 6" & 8" (STANDARD & METRIC) FLOW RATES ((Is) 0.0 31.5 63.1 94.6 126.2 0 500 1000 FLOW RATES (GPM) 1500 2000 MODEL 350DA 10" & 12" (STANDARD & METRIC) FLOW RATES (us) 0.0 31.5 63.1 94.6 126.2 157.7 189.3 220.8 VERTICAL INSTALLATION 50.5 103 U) 0 69 -J w 34 U) 4" (100mm)1 U) 0 a- 800 157.7 103 U) U) I 0 3(200mm) 69 w irLa- U) U) w ___________ 2500 252.4 283.9 103 I I U) mm o 1 69 X C1 34(/) U) W 0- 0 500 1000 1500 2000 2500 3000 3500 4000 4500 FLOW RATES (GPM) TYPICAL INSTALLATION Local codes shall govern installation requirements. Unless other- wise specified, the assembly shall be mounted at a minimum of 12" (305mm) and a maximum of 30" (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. Capacity thru Schedule 40 Pipe (GPM) Pipe size 5 ft/sec 7.5 ft/sec 10 ft/sec 15 ft/sec 2 1/2" 75 112 149 224 115 173 230 346 198 298 397 595 6" 450 675 900 1351 8" 780 1169 1559 2339 10" 1229 1843 2458 3687 12" 1 1763 1 2644 3525 5288 OUTDOOR INSTALLATION SPECIFICATIONS The Double Check Detector Back/low Prevention Assembly shall be ASSE® Listed 1048, and supplied with full port gate valves. The main body and access cover shall be epoxy coated ductile iron (ASTM A 536 Grade 4), the seat ring and check valve shall be NorylTM (NSF Listed), the stem shall be stainless steel (ASTM A 276) and the seat disc elastomers shall be EPDM. The first and second check valves shall be accessible for maintenance without removing the device from the line. The Double Check Detector Back/low Prevention Assembly shall be a WILKINS Model 350DA. WILKINS a Zurn company, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805/238-7100 Fax:805/238-5766 IN CANADA: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 1L2 Phone:905/405-8272 Fax:905/405-1292 Product Support Help Line: 1-877-BACKFLOW (1-877-222-5356) Website: http://www.zurn.com