Loading...
HomeMy WebLinkAbout2580 FARADAY AVE; ; FPC2020-0126; Permit(7city of Carlsbad 1iZ1iIlFiF1I]iI Fuieiaer.miIt Print Date: 05/11/2021 Job Address: 2580 FARADAY AVE. CARLSBAD, CA 92008 Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: Track #: Valuation: $0.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check#: Project Title: Description: OAKMONT OF CARLSBAD MARKETING BUILDING NEW FIRE ALARM SYSTEM Permit No: FPC2020-0126 Status: Closed - Finaled Applied: 07/22/2020 Issued: 08/25/2020 Finaled Close Out: 05/11/2021 Inspector: Final Inspection: FEE AMOUNT FIRE New Alarm System $1,265.00 --- Total Fees: $1,265.00 Total Payments To Date: $1,265.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov CA 3900 PROSPECT AVE., UNIT B! YORBA LINDA, CA. 92866 / PH: 877-225-2534 / FAX: 951-676-7451 C-10 LICENSE #521087 CONTACT: JOHN HASSLER RESPECTFULLY SUBMITS Oakmont Senior Living - Marketing Fire Alarm System Installation 2580 Faraday Ave. Carlsbad, Ca. 92008 F IN ACCORDANCE WITH ALL FEDERAL, STATE, AND LOCAL CODE REQUIREMENTS AS THEY PERTAIN TO THE INSTALLATION AND MAINTENANCE OF FIRE ALARM EQUIPMENT. I FIRE ALARM SYSTEM TABLE OF CONTENTS MODEL NUMBER DESCRIPTION VS4-RD Intelligent Fire Alarm System California State Fire Marshall's Listing ACE-1 1 Fire Alarm Document Cabinet California State Fire Marshall's Listing TG-7FS Cellular Alarm Communicator California State Fire Marshall's Listing Kl-PD Intelligent Smoke Detector California State Fire Marshall's Listing California State Fire Marshall's Listing GSA-M278 Manual Pull Station California State Fire Marshall's Listing GSA-CC 1S Synchronization Output Module GSA-CR Control Relay Module GSA-CTi I GSA-CT2 Input Modules California State Fire Marshall's Listing EGiF-VM / EGiF-HDVM I MG1T Field Configurable Horns & Strobes California State Fire Marshall's Listing California State Fire Marshall's Listing California State Fire Marshall's Listing WG4WF-HVMC Outdoor Rated Horn Strobe California State Fire Marshall's Listing G4LFWF-H I G4LFWF-HVM Low Frequency Audible Signals California State Fire Marshall's Listing California State Fire Marshall's Listing CATALOG NUMBER K85005-0135 7165-1657:0244 ED0549 7300-0553:0110 122012 7300-1402:0109 K85001-0646 7300-1657:0120 7272-1657:0331 K85001-0279 7150-1483:0139 K85001-0543 K85001-0239 K85001-0241 7300-1483:0115 K85001-0573 7125-1501:0146 7125-1501:0121 7300-1483:0146 K85001-0628 7125-1657:0311 K85001-0639 7135-1657:0319 7135-1657:0320 438D-10N5 Fire Alarm Bells K85001-0333 California State Fire Marshall's Listing 7136-1657:0150 0 V T-h-1-1., a 'U., g d ~ -w. fi - ' 9~-91 - ~ 8 Technology that saves lives Intelligent Fire Alarm Systems V S 1,y4) Overview Kidde brand intelligent life safety systems offer the power of high- end intelligent processing in configurations that deliver uncompli- cated solutions for small to mid-sized applications. With intelligent detection, electronic addressing, automatic device mapping, optional Ethernet® connectivity, and a full line of easily-configured option cards and modules, these flexible systems offer versatility that benefits building owners and contractors alike. The VS1 provides one Class A or Class B intelligent device loop that supports up to 64 device addresses, and two Class B Notifi- cation Appliance Circuits (NACs). Optional Class A device wiring is available with the use of a module. The VS4 provides one Class A or Class B intelligent device loop that supports up to 250 device addresses. Loop controller modules may be added in combination to expand total system capacity in 250-point increments to up to 1,000 device addresses. VS4 panels include four NACs that may be wired for either Class A or Class B operation. The RZ116-2 module adds even more capacity to VS installations by adding up to 16 conventional device circuits and two additional notification appliance circuits. This makes them ideal retrofit solu- tions that can accommodate new intelligent detectors, as well as existing conventional devices. VS Series supports a wide range of high-end features, including: Intelligent modules, detectors, and bases GSA-REL Releasing Modules R-Series remote annunciators Integrated Carbon Monoxide gas sensing with V-PCOS de- tectors including distinct audible signaling k > SmoL Building File Alrrn Solutions Th lilT rn - "wd-mi FDNY COA 6229 7165-1657: - 0244 53000 Features Auto-programming speeds installation time Supports V-Series intelligent modules and detectors Form C contacts for alarm and trouble, Form A for supervisory Electronic addressing with automatic device mapping Optional Ethernet port for diagnostics, programming and a variety of system reports Two programmable switches with LEDs and custom labeling Supports Genesis horn silence over two wires, and UL 1971-compliant strobe synchronization Supports GSA-REL releasing module for fire suppression Class B or Class A wiring Ground fault detection by module Supports up to eight serial annunciators, (LCD, LED-only, and graphic interface) Can use existing wiring for most retrofit applications Upload/download remotely or locally Two-level maintenance alert reporting Pre-alarm and alarm verification by point Adjustable detector sensitivity 4 x 20 character backlit LCD display Optional earthquake hardening: seismic Importance Factor 1.5 Standalone operation Transmission test frequency by hour Alarm ON command manually activates alarm condition Page 1 of 8 DATA SHEET V85005-0135 Not to Co used for :nstallutron purpoaos. Issue 1.3 Application Kidde VS Series life safety systems are powerful intelligent solutions • for small to mid-sized buildings. Advanced intelligent technology delivers the benefits of flexible system installation, while clean and easy-to-operate user interfaces make panel operation and system maintenance quick and intuitive. The smart choice Electronic addressing eliminates the tedium of setting dipswitches, and automatic device mapping ensures that each device resides on the system at its correct location. Meanwhile, innovative pro- gramming allows the designer to customize the system to pre- cisely suit the needs of the building owner. Reliability you can count on The inherent fault-tolerant characteristics of Analog/Address- able Technology boosts the reliability of Kidde fire alarm systems. When combined with VS Series smoke and heat detectors, these systems deliver a level of dependability not previously available for small to mid-sized applications. All Kidde systems are built to exacting reliability benchmarks and meet international standards for quality, in addition to agency listings for dependability. Clear-cut remote annunciation Remote annunciation is a strong suit of the VS Series fire alarm systems. Up to eight annunciators can be installed on a single system. Compatible annunciators include a range of LED and LCD models that provide zone or point annunciation, as well as com- mon control capabilities. VS control panels also supports graphic annunciation with optional graphic annunciator interface modules. Each interface provides common control and 32 LEDs. of strobes to UL 1971 standards. For Genesis devices, enabling this feature allows horns to be silenced while strobes on the same two-wire circuit continue to flash until the panel is reset. Flexibility built right in Two fully-programmable front panel switch/LED combinations provide an added measure of flexibility. Their slide-in labels take the mystery out of custom applications, and present a clean finished appearance. Perfect for retrofits Kidde VS Series control panels are particularly well-suited to retrofit applications. All connections are made over standard wiring - no shielded cable required. This means that in most situations existing wiring can be used to upgrade a legacy control panel to VS technology without the expense or disruption of rewiring the entire building. VS control panels also support the ingenious RZI1 6-2 zone module, which adds up to 16 conventional circuits and two NACs. This combination easily accommodates new intel- ligent detection alongside existing conventional circuits, making it an superior solution in the retrofit market. Scalable lP and Cellular Communications Several popular third-party IF/Cellular communicators have been tested with the VS control panels and are compatibility listed to UL864. The IP/Cellular communicators meet NFPA72 2013 edition requirements for sole or secondary transmission paths. Using IP/ Cellular communicators can reduce the cost of ownership by eliminating POTS lines. Please see the VS control panel compat- ibility documentation part number 3102354-EN for a full list of compatible communicators. . Signals with a difference A complete line of accessories VS Series NACs are configurable to fully support the advanced VS Series life safety systems are supported by a complete line of signaling technology of Kidde Genesis and Enhanced Integrity no- analog/addressable detectors, modules and related equipment. tification appliances. These devices offer precision synchronization Consult the Ordering Information section for details. Programming and remote diagnostics Kidde VS Series life safety systems are simple to set up, yet offer advanced programming features that put these small building panels into a class of their own. The auto programming feature quickly gets the panel operational using factory default settings. Basic zone and point settings can be programmed through the front panel interface, so the system is up and running in no time. For more advanced system configuration and correlation groups programming, VS Series systems interface to a PC running com- patible VS-CU software. This option offers full system configura- tion in the familiar Windows® operating environment. Connection is made to a laptop through the panel's optional RS-232 communi- cations port, which can also be used to connect a system printer. Among the many innovative features of VS Series control panels is the optional network card. This module provides a standard 10/100 Base T Ethernet® network connection that permits access to the control panel from any remote location with the correct communications protocols. The connection can be used to down- load to the panel from the VS-CU, or upload and view system reports using the VS-CU. Page 2 of 8 Dimensions ii' {2) ) (4) oei'l Surface Mounting Holes (3) Backbox with Door Attached Semi-flush mounting Holes (4) Backbox with door and trim kit attached, Panel dimensions, in (cm) Model 01 02 D3 D4 05* 06 07 08 09 28.0 3.85 9.0 22.0 15.75 10.25 4.9 30.1 2.7 VS4 (71.1) (9.8) (22.8) (55.8) (40.01 (26.0) (12.4) (76.4) j (6.8) vsi 21.5 3.85 7.5 15,5 14.25 10.25 4.9 23.6 T 2.7 154.61 (9.8) 1 (19.0) (39.4) (36.2) (26.01 (12.4) (59.9) (6.8) * Add 1-1/2 in. (3.81 cm) to Dl and 05 dimensions for trim kit. The trim kit provides 0. 75 inches (1.9 cm) of trim to the top, bottom, and sides of the backbox. DATA SHEET V85005-0135 Not to be used for inslallation purpoucs. Issue 1.3 .Available system reports include: Correlation groups, Device de- tails, Device maintenance, History, Internal status, System configu- ration, System status, Walk test, Dialer, and CO runtime. Panel Layout '•' 1 Transformer 2 Main AC wiring block & fuse holder 3 RS-232 card connector (J3) 4 Dialer card connection lJ8l 5 Ethernet card connector (J1) 6 Main circuit board 7 Panel backbox enclosure 8 Operator interface 9 SLC card connector lJ7l 10 Class A card connector (J2) 11 Tie wrap mounts 12 LED expander connector (J6) 13 Standby batteries System Layout VS4) Any combination of two sin( e, fw4 Standard Loop: 250 points (one expansion slot) Up to 125 sensors and 125 modules per loop --- V-SLC2-1 Expander Loop: 250 points (one expansion slot) Up to 20,000 feet of wiring per loop ----------------------------------------- ------------------ t Er~jr ss B or two optional Class A NACs Optional 10 A or 6.5 A Booster Ethernet (SA-ETH) DACT/Laler(sMJACT) fFFI- I RS-232 (SA-232) Relays: Two Form C, one Form A Each VS4 panel has room for up to two device loop controller modules in any combination of single or dual 250-device loops. VS4 comes with one loop that supports up to 125 detectors and 125 modules. vs1 Loop supports up to 64 intelligent devices of any type. Up to 20,000 feet of wiring, jJ'lTwo la B or two oi.wonal Class A NACs Optional 10 A or 6.5 A Booster Power Supply ' ,r} L eight recn: ciators .: Ethernet (SA-ETH) DACT/Dialer (SA-DACT) J RS-232 (SA-232) Relays: Two Form C, one Form A Each VS1 panel ships with one device loop controller that sup- ports 64 devices of any type. This panel's device capacity cannot be expanded. V-SLC2-2 Expander, Loop 1 of 2: 250 points J (one expansion slot) V-SLC2-2 Expander, Loop 2 of 2: 250 points i Four Class B or two optional Class A NACs Up to eight remote annunciators - Sixteen Conventional lDCs, two additional NACs with RZ116-2 module 71e- or dual device loop modules Page 3 of 8 DATA SHEET V85005-0135 Not to no wed 'or nsta:taton purpo-ses. Issue 1.3 doss A woing Auxiliary & smoke power outputs (TB3) The control panel provides two auxiliary power outputs that can be used for powering ancillary equipment such as remote annunciators and two wire smoke detectors. Aux 2 can be software selected to operate continuously. The circuit is supervised for shorts and grounds. (2) Circuit specifications Circuit voltage 21.9 to 28.3 V Resettable circuit 24 VDC nominal at 500 mA (Aux power 2) Continuous circuit 24 VDC nominal at 500 mA. (Aux power 1) Use this circuit for powering two-wire smoke detectors. Note: Any current above 0.5 amp connected to both Aux 1 and 2 will reduce the total available NAC power by that amount. Alarm, trouble, and supervisory relay (TB3) The trouble relay is normally-open, held closed, and opens on any trouble event or when the panel is de-energized. The supervisory relay is normally-open, and closes on any supervisory event. The alarm relay changes over on any alarm event. Relay specifications Trouble Supervisory Alarm Smoke/Aux Alarm [ Trouble I Supervisory Type Form C Form A Voltage 24 VDC at 1 A resistive 24 VDC at 1 A resistive Relay circuits can only be connected to power-limited sources. Annunciator loop (TB4) The control panel provides a connection for up to eight serially driven and supervised remote annunciators. Circuit specifications Device loops Class B (Style 'f) or Class A (Style Z) Circuit voltage 2.55 V Circuit current 30 mA max Circuit Up to 8 annunciators or 4000 feet impedance Class B Channel i channel 2 + + Annunciator Tr!84 cEO (A) IN T CHI (-I IN ® CH2 (+) IN IS) CH2 IN Class A Channel 1 Channel 2 + + Annunciator CHI () IN ¶4 CHI (-I IN CH2 (A) IN CH2 IN Wiring & Configuration ,,Device loop The system provides one device loop circuit with a total capacity of 125 detectors and 125 module addresses. The loop circuit is supervised for opens, shorts, and grounds. Circuit specifications Device loops One Class B or A One Class B or A loop, loop, supporting 125 supporting 64 devices of detectors and 125 any kind. modules. Expandable to four loops. Communication Maximum 20 V peak-to-peak line voltage Circuit current 0.5 A max Circuit 660 total, 0.5 1k, max impedance Isolators 64 maximum Signal Supported on a system-wide basis (all device loops) Synchronization when using an addressable notification appliance circuit (NAC) module and Genesis or Enhanced Integrity notification appliances. Cl— A wiring Loop card ~d- device Data Line *Notification appliance circuits (T82) VS4 control panels come equipped with four notification appliance circuits. VS1 control panels come with two NACs. Each circuit can be individually configured for continuous, temporal, synchronized, and coded output. Specifications NOE VS1 - Circuit Type 4 Class B or 2 Class A 2 Class B or 2 Class A with SA-CLA module Voltage _ 24 VFWR Current 6.0 A total, 2. 5 A max. 3.75 A total, 2.5 A max. per circuit at 120/230 per circuit at 120/230 VAC 60 Hz. VAC 60 Hz. 5.0 A total, 2.5 A max. 3.0 A total, 2.5 A max. per circuit at 230 VAC per circuit at 230 VAC 50 Hz. 50 Hz. Impedance 26 0 total, 0.35 pF max EOLR 15K0,1/2 W Synchronization Supported system-wide O000 B wiring TuB Marking indicates output signal polarity when the circuit is active. Polarity reverses S when the circuit is not active. Wire notification appliances accordingly. Notification appliance polarity shown in active state. SLC A Data Line Loop card device device _$. I EOLR - V N!Nij o ~FNACI NAC Page 4 of 8 DATA SHEET V85005-0135 Not to be usod for instalLtion purposes. Issue 1.3 S Kidde VS Series panels are supported by a complete line of mod- ules and related equipment that enhance performance and extend system capabilities. Option cards plug directly into the control panel main circuit board or are connected to it with a ribbon cable. After installation, terminals remain accessible. The cabinet pro- vides ample room for wire routing, keeping wiring neat at all times. Single and Dual Loop Controller Cards The V-SLC2-1 is a single loop controller card that can be used with the VS1 as a replacement for the standard 64-point loop, or with the VS4 as a 250-point expansion module. The V-SLC2-2 is a 500-point dual loop controller card for the VS4 that provides two IDC circuits, each with 125 detector addresses and 125 module addresses. V-SLC21 e'V-SLC11-21 VS4: one loop, VT4: two loops, 500 device addresses , device addresses VS1: 64 addresses P ,,r flIoo A Standby: 55 mA Standby: 45 mA Alarm: 80 mA Alarm: 70 mA Note: These ratings do not include the use of two-wire smoke modules. munication Line I Max. 20.6 V peak-to-peak Voltage Terminal Rating WG (0.75 to Circuit Current n c A Max total loop 660 resistance Max total loop .5 p Isolators 64 isolators maximum per loop (total both isolator bases and modules) Ground Fault to 5 kO Operating 32 to 120°F (0 to 49°C) Environment 0 to 93% noncondensing at 90°F (32°C) SA-ETH Ethernet Interface Card SA-ETH wiring The SA-ETH card provides a To network Network cable—f connection standard 10/100 Base T Ether- net network connection for connecting to an intranet, a local network, or the Internet. The card can be used to download configuration programming from "00 ID the VS-CU to the panel. The Ethernet card is installed on the plastic assembly and con- nects to the main circuit board via a ribbon cable. SA-ETH_specifications ____________ Ethernet 10/100 Base T Operating environment Temperature 32 to 120°F (0 to 49°C) Humidity 0 to 93% RH, noncondensing at 90°F (32°C) Page 5øf8 RZ116-2 Remote Zone Interface Module The RZI16-2 Addressable Remote Zone Interface Module is an addressable device that provides connections for sixteen Class B Initiating Device Circuits and two Class B Supervised Output Circuits. The inputs and outputs can be configured individually for several device types. The RZI16-2 requires 18 consecutive addresses on the Signaling Line Circuit (SLC). Addresses are assigned electronically. There are no address switches to set. The RZ116-2 incorporates two 8-segment DIP switches that are used to select the Alarm or Supervisory default device type for each of the 16 IDC circuits. The module also includes one 4-seg- ment DIP switch used to select the default Relay or NAC output device type. Device types other than the default are accomplished through programming. RZ116-2 Specifications Voltage 24V/Aux nominal: 24 VDC Supervisory current: 250 mA at 24 VDC nominal Alarm current: 1000 mA 24V/Aux minimum: 18.4 VDC 24V/Aux maximum: 26.4 VDC NAC1, NAC2 nominal: 24 VDC Current Standby current for 4.7 k EOL (U.S.) 4.8 mA' circuit Standby current for 3.9 k EOL (Canada) 5.7 mA' circuit Alarm current at nominal voltage 31.1 mA/ circuit Relay outputs Quantity 2 Type Rating (pilot duty) Programmable 24 VDC at 2.5 A Input circuit wiring 25 0 per wire resistance Initiating device circuits Quantity 16 EOL resistor 4.7 kc) (U.S.); 3.9 kO Canada Zone voltage 22.78 V for 4.7 kO (U.S.) 22.08 V for 3.9 kO (Canada) Alarm current 31.1 mA/ channel at nominal voltage Alarm impedance range <680 0 Trouble impedance range > 5.55 kO Supervised output circuits EOL resistor 15 kO Quantity 2 Short circuit detection <2.6 kO Open circuit detection > 61.9 kO Contact ratings 24 VDC at 2.5 A (5 A for two NACs) Compatible cabinets MFC(A), VS4, APS DATA S" T V850050135 Not to be used N. ,. .. purposes, Issue 1.3 Specifications Device Addresses Wiring Operating Voltage Operating Current (fully loaded loop) SA-232 RS-232 interface The SA-232 card provides an RS-232 in- SA-232 wiring terface with VS panels. It can be used for GNU (black wire) TXD (white wire) connecting a printer to the control panel F F RXD (red wire) to print system events. The card also can be used for connecting a computer to download a configuration program from the VS-CU to the control panel. fl fl The RS-232 card is installed on the plas- tic assembly and connects to the main circuit board via a ribbon cable. SA-232 specifications Operating voltage Standard EIA-232 Terminal rating 12(018 AWG (0.75 to 2.5 sq mm) Operating environment Temperature 32 to 120°F (0 to 49°C) Humidity 0 to 93% RH, noncondensing at 90°F (32°C) SA-CLA Class A Module (VS1 only) The SA-CLA card provides Class A capability for NAC wiring. Its terminal block provides the wiring connection for NAC return wiring. The card is required for annunciator Class A wiring even though this wiring does not return to the SA-CLA card. The SA- CLA is compatible with VS1 control panels only. VS4 panels are Class A Ready. The SA-CLA is installed directly to the control panel circuit board using its plastic standoffs and plug connection. SA-CLA specifications Operating voltage 24 VF\NR Operating current 3.75 A F\NR total at 120/230 VAC 60 Hz 3.0 A FWR total at 230 VAC 50 Hz 2.5 A max per circuit Circuit impedance 26 ohms, 0.35uF Terminal rating 12 tol8 AWG (0.75 to 2.5 sq mm) Operating environment Temperature 32 to 120°F (0 to 49°C) Humidity 0 t 93% RH, noncondensing at 90°F (32°C) D16L-VS LED Display Expander (VS4 only) The D16L-VS LED Display Expanders provide LED annuncia- tion for up to 16 zones. It provides two LEDs for each zone. Two Dl 6L-VS LED display expanders can be installed in each VS4 panel. QJ SA-DACT Dialer The SA-DACT provides communications between the control panel and the central station over a telephone line system. It .transmits system status changes (events) to a compatible digital alarm communicator receiver over the public switched telephone network. The dialer is capable of single, dual, or split reporting of events to two different account and telephone numbers. The modem feature of the SA-DACT can also be used for uploading and downloading panel configuration, history, and current status to a PC running the VS-CU. SA, DACT ri Phone line 2 wiring To wall Phone line 1 phone jack Phone cables (supplied) The dialer phone lines connect to connectors on the dialer's main circuit board. Phone line 1 connects to connector J4 and phone line 2 connects to connector J1. LDL1'otf flt=no The SA-DACT queues mes- sages and transmits them based on priority (alarm, supervisory, trouble, and monitor). Activations are transmitted before restora- tions. The SA-DACT is installed on the plastic assembly and connects to the main circuit board via a ribbon cable. .iJpecifications Phone line type One or two loop-start lines on a public, switched network Phone line connector RJ-31/38X (C31 /38X) Communication formats Contact ID (SIA DC-05) Operating environment Temperature 32 to 120°F (0(049°C) Humidity 0 to 93% RH, noncondensing at 90°F (32°C) Compatible DACRs Receiver Models Formats Ademco 685 Contact ID FBI) CP220 Contact ID Osborne-Hoffman OH 2000 Contact ID Bosch 06600 Contact ID Silent Knight 9800 Contact ID Sur-Gard SG-MLR1, MLR2 Contact ID Jim LED 1 LED 2 LED Expander 1 LED Expander 2 Jarm/non-alarm and trouble zone LEDs 1] Page 6 of 8 DATA SHEET V85005-0135 Not to be usUd tot pnta)latioti purposes, issue 1.3 Specifications Device loops Notification appliance circuits Primary power Base panel current standby Base panel current alarm Input zones Remote annunciator Operating voltage Auxiliary power output circuit Loop circuit Batteries SA-DACT dialer Ground fault impedance Alarm contact Trouble contact Supervisory contact Environmental Terminal rating vs.l 1 loop Class B or Class A (Styles 4, 6, 7) supporting up to 1 loop, expandable to 4, Class A or B (Styles 4, 6, 7), 64 device addresses (any combination of detectors and each loop supporting up to 250 device addresses (125 modules) detectors and 125 modules max.). Addresses 1 t 125 are Maximum T-taps: 63 for detectors and addresses 126 to 250 are for modules (each device can be on its own branch) Maximum T-taps/loop: 124 2 Class B (Style Y), Class A (Style Z) optional 4 Class B (Style Y) or 2 Class A (Style Z) 3.75 A FWR total at 120/230 VAC 60 Hz 6.0 A FWR total at 120/230 VAC 60 Hz 3.0 A FWR total at 230 VAC 50 Hz 5.0 A FWR total at 230 VAC 50 Hz 2.5 A FWR each max. per circuit 2.5 A FWR each max. per circuit 120 VAC, 60 Hz, 1.3 A max. 120 VAC, 60 Hz, 2.0 A max. 230 VAC, 50-60 Hz, 0.62 A max. , 230 VAC, 50-60 Hz, 0.97 A max. 155 mA 172 mA 204 mA 267 mA 16 max. 32 max. 8 drops max., RS-485 Class B, Class A is optional 8 drops max., RS-485 Class A or B Data line length: 4,000 ft. (1,219 m) Data line length: 4,000 ft. (1,219 m) 24 VDC panel Aux power 1: 500 mA, 24 VDC Aux power 2: 500 mA, 24 VDC (1 A possible if you reduce total available NAC power by 500 mA) Output: 28.3 to 21.9 VDC, special application Note: For a list of compatible devices, see the VSI and VS4 Series Compatibility List (P/N 3102354-EN) Maximum loop resistance: 66 0 Maximum loop capacitance: 0.5 pF Communication line voltage: Maximum 20.6 V peak-to-peak Operating currentfG(il6ded loop) Stand by: 55 mAJ45 mA Alarm: 125 mA/1 15 mA (not including two-wire smoke modules) Circuit current: 0.5 A max. Style 4, 6, and 7 wiring Max. resistance between isolators: Limited only by overall wire run lengths 64 isolators maximum per loop (total both isolator bases and modules) Type: Sealed lead acid Voltage: 24 VDC Charging current: 2.47 A max. Amp hour capacity: 26 Ah Standby operation: 24 hour or 60 hour Placement: Up to two 10 Ah batteries will fit in the VS1 control panel cabinet and two 18 Ah batteries will fit in the VS4 control panel cabinet. If larger batteries are required, use a battery cabinet. Phone line type: One or two loop-start lines on a public, switched network Phone line connector: RJ-31/38X (C31/38X) Communication formats: Contact ID (SIA DC-05( Operating current Standby/Alarm: 41 mA Max.: 100 mA FCC registration number: GESAL01 BSADACT Industry Canada Registration number: 3944A-SADACT Ringer equivalence number: 0.1 B 0 to 5 kO Form C N.C. 24 VDC at 1 A (resistive load) Form C 24 VDC at 1 A (resistive load) Form A N.C. 24 VDC at 1 A (resistive load) Temperature: 0 to 49°C (32 to 120°F) Relative humidity: 0 to 93% noncondensing All terminals rated for 12 to 18 AWG (0.75 to 2.5 mm2) DAt V850050135 Not to be , purDoses, Issue 1.3 fl Page 8 of 8 Ordering Information Part Description VS4 Fire Alarm Systems VS4-G Four loop system with one 250-point loop installed. llOv, gray door. VS4-G-2 loop installed. 239gray VS4-G-2-PG Four loop system with one 250-point loop installed. 230v, gray door, Portuguese. VS4-G-2-SP Four loop system with one 250-point loop installed. 230v, gray door, Spanish. VS4-GC Four loop system, one 250-point loop installed. 110v, gray door, LED strips, Canada. VS4-GD Four loop system, one 250-point loop installed. 110v, gray door, with dialer. VS4-GF French Canada. VS4-G-PG Four loop system with one 250-point loop installed. 11 pgray door, Portuguese. VS4-G-SP Four loop system with one 250-point loop installed. 11 0v,gry9)panish. VS4-R Four loop system with one 250-point loop installed, 110v, red door. VS4-R-2 Four loop system with one 250-point loop installed. 230v, red door. S4-RD) Four loop system, one 250-point loop installed. 110v, red door, with dialer. SA-TR1M2 VS4 Flush mount trim, black. VS1 Fire Alarm Systems VS1 -G One loop system with one 64-point loop installed. 110v, gray door. VS1-G-2 VS1-G-2-PG One loop system with one 64-point loop installed. 230v, gray door, Portuguese. VS1 -G-2-SP One loop system with one 64-pn jq9y,_Rra door, Spanish. VS1 -GD One loop system, one 64-point loop installed. 110v, gray door, with dialer. VS1 -GL One loop system, one 64-point loop installed. 110v, gray r, English Canada. VS1-GL-F One loop system, one 64-point loop installed. 110v, gray door, French Canada. VS1 -G-PG One loop system with one 64-point loop installed. 11 ,Qgray door, Portuguese. VS1 -G-SP One loopym wit~h i!tl92pinstalled. I by, panish. - VS1-R One loop system with one 64-point loop installed. 110v, red door. VS1 -R-2 One loop system with one 64-point loop installed. 230v, red door. VS1-RD One loop system, one 64-point loop installed, 110v, red door, with dialer. SA-TRIM1 VS1 Flush mount trim, black ODtion Cards V-SLC2-1 -Expansion module, one 250-device loop. For y4 only. .V-SLC2-2 Expansion module, two 250-device loops, 500 devices total. For VS4 only. RZli 6-2 Remote Zone Interface Module. 16 Class B lDCs, 2 Class B Output. Bracket included. SA-DACI Dual Line Dialer/Modem, supports Contact ID, mounts in cabinet on base plate. SA-232 RS-232 Serial Port for connection to printers & computers, mounts in cabinet. SA-ETH Ethernet Port, Slave, mounts in cabinet on base plate. ____________ SA-CLA Class A adapter module. Provides Class A capacity on NACs. Mounts in cabinet on main board. VS1 systems only. D1 6L-VS LED Annunciator module, 16 X 2-LED zones (4 programmable for sup). Mounts in cabinet to right of LCD display. For VS4 only. D8RY-VS Canada only: LED Annunciator module, two LEDs per zone, 16 zones (4 alarm only, 8 supervisory only, 4 alarm or supervisory). Mounts in cabinet. For VS4 only. Accessories CTM City Tie Module. 2-gang. Connection to a local energy fire alarm box. MFC-A Multifunction Fire Cabinet, 8" x 14" x 3.5' - red. BC-1 Battery Cabinet. 14.0" x 18.25' x 7.25'. Holds two 12V24A batteries. BC-i R Battery Cabinet - Red. 14.0" x 18.25" x 7.25". Holds two 12V24A batteries. GSA-REL Releasing Module BC-1 EO Seismic hardening Kit for VS Series panels. Includes battery hardening for BC-1 enclosure and components to harden panel internal components. Programming Tools VS-Cu \.ISeriescorifiSSeriesconfiuration and diagJcli,_ 260097 R5232 cable, 4 conductor, DB9 PC interface DATA SHEET V850050135 Not to on used fo netan:tron purposes. Issue 1.3 07 P-7K*Odde lechnoogy that saves lives Contact us... Email: kidde.fire@fs.utc.com Web: kidde.corn/engineeredsysterns 1016 Corporate Park Drive Mebane, NC 27302 Kidde is a registered mark in the United States and other countries. © 2018 Walter Kidde Portable Equipment. All rights reserved. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL 0S FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-1657:0244 Page 1 of 2 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, lnc.8985 Town Center Parkway, Bradenton, FL 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.micochero@carrier.com DESIGN: Single and multi-loop analog addressable fire alarm control unit. Local, local with shunt, auxiliary, remote station, central station, releasing device. Power limited, non-coded, coded, shunt, reverse polarity, DACT, manual, automatic waterflow and sprinkler supervisory service. Models "EST" i01000G, 01000G-2, i01000GD, i01000R, iO1000R-2, i01000RD, iO64G, 1064-GD, i064-R, i064-RD, i064G-2, i064R-2: i0500G, i0500GD, i0500R, i0500RD, i0500G-2, iO500R-2. Models "Vigilant/Kidde" VSI-G, VSI-GD, VSI-R, VS1-RD, VS1-G-2, VSI-R-2; VS2-G, VS2-GD, VS2-R, VS2-RD, VS2-G-2, VS2-R-2, vs4-G, vs4-G-2, vs4-GD, vs4-R, vs4_r-2, vs4-RD,. Models "FireworXlKidde" FX-64G, FX-64GD, FX-64R, FX-64RD, FX64G-2, FX-64R-2, FX-254G, FX-254GD, FX-254R, FX-254RD, FX254G-2, FX-254R-2, FX-1 000, FXI 000D. Models "Edwards Signaling" E-FSA64G, E-FSA64GD, E-FSA64R, E-FSA64RD, E-FSA250G, E-FSA250GD, E-FSA250R, E-FSA25ORD S ' System Components: SA-DACT; Dialer SA-CLA; Class A Adapter SA-ETH; Ethernet Adapter SA-232; R5232 Module D16L-i0, -VS, -Fa, D8RY-i0-1, D8RY-i0-2, D8RY-VS, 16 Zone Front Panel LED XAL25O, V-SLC, XAL127; SLC Loop Driver io-SDCI, V-SLC2-1, FX-SLC1 Single SLC Card, 250pt io-SDC2, V-SLC2-2, FX-SLC2 Dual SLC Card, *500pt *pT1..S: System Printer *pT1..P: System Printer Parallel Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120/230 VAC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. 10-24-16 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other 0 Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTIL.LO,, M.E., F.P.E. Fire Engineering Division Listing No. 7165-1657:0244 Page 2 of 2 MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as fire alarm control units for use with separately listed compatible initiating and indicating devices. *These control units meet the requirement of UL 864, 9th Edition Standard. 10-24-16 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other S Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, ME, F.P.E. Fire Engineering Division SIGNALING _ /FADLISTED ACE-1 I I FIRE ALARM DOCUMENTS The FAD is the perfect fit to meet the demanding code requirements today. SAE's number one goal is to manufacture code compliant solutions and this product allows you to do just that. NFPA 72 2007 section 6.2.2.1 states, "A record of installed software and firmware version numbers shall be maintained at the location of the fire alarm control unit." This durable 16 gauge steel enclosure with a solid piano hinge and key lock will keep all of your code required documents in one safe place. With a 4GB USB flash drive it stores your fire alarm software safe and secure eliminating the occurrences of the soft- ware not being on site when technicians arrive to service the system. Along with your fire alarm soft- ware you can store your test & inspection docu- ments, service records, manuals & AS built drawings for the system. Using a standard USB B connector it allows you to plug in with any standard SIB printer cable to upload or download information. The FDB is designed to hold critical manuals and documents with a durable steel retainer. It has designated hooks to organize key rings and hold important business cards for easy access and reference. Inside the cover it has a organized note table that allows for documentation for passwords and other critical system information. Standard Features: Installed with a 4 gig digital flash drive with USB B connector 2 Key ring hooks to hold system keys Business card holder for key contacts Overall Dimensions are 12" x 13" tall and 2 ¼ deep 16 gauge steel box and cover for security Durable powercoat baked on finish other colors available Standard %"cat 30 key lock other lock as- semblies available Solid stainless steel piano hinge Permanently screened white ink 1" high "Fire Alarm Documents" Legend sheet for passwords and system information ISO Sp9t NFPA COMPANY fl Ma de ./ Space Age Electronics, Inc. 2009 ED0549 L110559 Rev.D 1/2 Space Age Electronics, Inc. www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax No Excuses, Just Solutions! Key Ring Hooks Business Card Holder rd MW W A LIN Specifications: The fire alarm documents box (FAD) shall be UL Listed, constructed of 18 gauge cold rolled steel. It shall have a red powder coat epoxy finish. The cover shall be permanently screened with 1" high lettering "FIRE ALARM DOCUMENTS" with white indelible ink. The access door shall be locked with a 3/4" barrel lock and the hinge shall be a solid width 12" stainless steel piano hinge. The enclosure will supply 4 mounting holes. Inside the enclosure will accommodate standard 8 1/2 x 11 manuals and loose document records that will be protected within the enclosure. A legend sheet will be permanently attached to the door for system required documentation, key contacts and system information. The FAD will have securely mounted inside a minimum of 4 Gigabyte digital flash memory drive with a standard USB B connector for uploading and downloading information. The drive shall not be accessible without tools to any person whom gains access to the records. The enclosure shall also provide 2 key ring holders with a location to mount standard business type cards for key contact personnel. D USB Storage Interface Requires Standard US B-B Connector Property tnfo,rnodon Mlnlnstn, Roqsi,od 005n,onthoon (SIG-FUN) Cer ostiono end ApproVdlo :. 16,1 System Installoton Contacts,; N!fl 16.5 U~oyHngJsiostc6ofl: NJA Edaa.o IAS EqdipntAnt Intonmedon ,d- Se.morfl.Aonam SSCO.Aks.ORA.O SOS.a MnO,tee S1721 L'1144 R-1 Legend sheet for storing system information including contacts, sign-off, maintenance & test information, and alternate locations of additional records. Ordering Information: Part # Description SSU00685 Fire Alarm Storage Cabinet RED 5SU00686 Custom screening with your Logo Check out our Infinity line eFAD single gang 2 Gig digital storage solutions (IAMEFAD) This document is subject to change without notice, see doc # ED0479 for legal disclaimer ED0549 L110559 Rev.D 2/2 Space Age Electronics, Inc. www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax No Excuses, Just Solutions! CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING BUILDING MATERIALS LISTING PROGRAM I LISTING SERVICE LISTING No. 7300-0553:0110 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SPACE AGE ELECTRONICS58 Chockett Road, Sterling, MA 01564 Contact: Robert Scholl (508) 485-0966 Fax (508) 485-4740 Email: bobs@lsae.com DESIGN: Models TC2-32, TC1-18, TCX/A64, TCX/D 128, ACE/A, AC2, ACE/D, IF-2, lF1, IFX/A and lFX/D enclosures. Models ACE-11,ACE-12 and ACE-13, *ACE2424, *ACE 3036, *ACE 2436, *ACE 3048 document cabinets. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as fire alarm equipment enclosures and document cabinets for use with listee's fire alarm equipment. Refer to listee's Installation Instruction Manual for details. I 1 0 02-09-16 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division TG-7FS CELLULAR ALARM COMMUNICATOR LTE-A FOR LTE NETWORKS COMMERCIAL FIRE PRODUCT FEATURES 1- Certified for use on the AT&T LTE network for sunset-free installations. I- Meets UL 864 requirements for sole, primary or backup path communications. I- Minimizes false alarms by providing dual paths for self-tests. Falls back to 3G/4G if an LTE network is not available, for extended network coverage. The Telguard TG-7FS LIE-A is the ideal cellular alarm communications solution for commercial fire systems. The TG-7FS LTE-A transmits alarm signals from the fire panel over the digital cellular network to the designated monitoring station. Compliant with the 2019 and earlier editions of NFPA 72, the TG-7FS LIE-A can serve as the sole communication path for the fire alarm system. It replaces all of the landlines currently dedicated to the master control unit. On average, cellular monitoring costs the end user significantly less than a dedicated landline. For each landline replaced with a TG-7FS LIE-A, the monthly communications bill decreases. I TE LG UAR D AMETEK By being able to signal failures to the central station within sixty minutes of an outage, the TG-7FS LIE-A can be installed as the sole path for commercial fire installations. For existing installations, all landlines can be swapped for a single TG-7FS LTE-A because of the new five or sixty minute supervision modes. The TG-7FS LTE-A can also be installed as a backup path and upgraded to sole path at a later date. ref— guard UTd a es dtr l F1 easy e orta. The st al forward we interrace allo ec td n cen s a ions o q ic I ffic.ien t oriz ho d p 0 I t C-c a me o içivar ! l6tr cowjiflLa tcL, kHe iullJ I 10 OOtiId ilb e ela o Me utUt fo rip in olpnele t Le o TG-7FS LTE-A CELLULAR ALARM TE LG UAR D AMETEK Tra,1smit PoWr - I _ 11 Power Gonsumpitton. Source: 12 8OED L 1[1 ccessor [ Mad RAMS ti1 LjiE18Is 2, 4 3J Ban Is. Antnna: iq e wi o cab mu tin ace. pa 1, 2,2 mLcpmpapt IilIails • hipping eig Operating Environmonti OOtc;_p to opo ondenrng [S 1 s 04 e LTEI C L., fin. (0pti,,U) Telguard technology allows full data reporting for unlimited point-to-point signal details and maximum transmitting power for superior in-building penetration. Telguard products are easy to install, economical, and UL Listed. Accessories TG-PEM: Power & Expansion Module for powering the TG-7FS from 24V DC alarm panel: no need to have an electrician install a dedicated outlet. ACD 12, ACD 35, ACD 50, ACD 100: 12/35/50/100 feet of low loss, high performance cable. HGD-O: High gain directional antenna. EXD-O: External antenna. UL Listings Commercial Fire 864 • Control units & accessories for fire alarm systems Commercial Burglary 365 • Police Station connected burglar alarm units and systems 1610 • Central station burglar alarm units; Line security servcies Residential 985 • Household fire warning systems 1023 • Household burglar alarm systems ULC Listings S545 • Canadian household fire warning systems S304 • Canadian commercial burglary alarm systems S559 • Equipment for fire signal receiving centres and systems C0123 • Canadian household burglary alarm systems * For the most current product specifications and UL Listings visit www.Telguard.com. SECURITY SIGNALING cir UL us ASSOCIATION" [LJ]ELECTRONIC EocIise Shflegic rrnv, Connected LISTED INTERNATIONAl. Gold by AT&T Telguard, a Division of Telular Corporation • 3225 Cumberland Blvd SE • Suite 300 Atlanta, GA 30339 USA 800.229.2326 I telguard.com Copyright ©2019 Telguard, a Business Unit of AMETEK. Inc. • All Rights Reserved O62Oi9Re5 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1402:0109 Page 1 of 1 CATEGORY: 7300-- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: TELULAR CORP.3225 Cumberland Blvd, Suite 300, Atlanta, GA 30339 Contact: Tim .Masters (678) 264-2012 Fax (678) 264-2062 Email: Tim.Masters@ametek.com DESIGN: Models TG7LAA02, TG7LA00I, TG7LAA01, TG7LA002, TG7LAF01 ,', TG7LAF02, *TG7UBLA and TGKITLA2 digital cellular radio alarm transmission system for fire/burglar alarm system control units. Models TG7LAA02 and TG7LA002 are household application. Model TG7LAF0I, TG7LAF02, and TGKITLA2 are for commercial application. Refer to listee's printed data sheet for additional detailed product description and operational considerations INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as digital cellular radio alarm transmission devices to provide a standalone transmission path (cellular) for a listed compatible fire and burglar alarm control unit. It may also provide a backup communication path when used in conjunction with a DACT. This product is to be connected to a listed control panel in accordance with the installation instructions provided by the manufacturer. NOTE: Burglary and other non-fire functions were not examined. * Revised 11-27-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other S Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division i.Ic'ç 0, Keel[goit Initiating Devices _JEL .RONi UPOR Technology that saves lives In telligent Detector 101=11 MA The Kl-PD optical smoke detector brings advanced sensing technology to a practical design that increases efficiency, saves installation time, cuts costs, and extends life safety and property protection capabilities. Continuous self-diagnostics ensure reli- ability over the long-haul, while environmental compensation helps reduce maintenance costs. Like all Kl Series detectors, the Kl-PD is an intelligent device that gathers analog information from its optical sensor, converting this data into digital signals. To make an alarm decision, the detector's on-board microprocessor measures and analyzes sensor read- ings and compares this information to historical data. Digital filters remove signal patterns that are not typical of fires, thus virtually eliminating unwanted alarms. - I .0~ =~~, - /' , 4' -Q S853 0 Standard Features Note: Some features described here may not be supported by all control systems. Check your control panel's Installation and Operation Guide for details. Next generation optical smoke sensing technology Wide 0.53 to 3.94 %/ft. (1.7 to 12.35 %/m) smoke obscuration Uses Existing Wiring Automatic Device Mapping Up To 250 Total Addresses Per Loop Two Levels of Environmental Compensation Two Levels of Dirty Detector Warning Twenty Pre-Alarm Settings Five Sensitivity Settings Non-Volatile Memory Electronic Addressing Identification of Dirty or Defective Detectors Automatic Day/Night Sensitivity Adjustment Bicolor (Green/Red) Status Led Standard, Relay, Fault Isolator, and Audible Mounting Bases Sensor Markings Provide Easy Testing Identification Pagel of 4 DATA SHEET K85001 -0646 Not to be used for installation purposes. Issue 1 The KI-PD detects extremely small particles of combustion and .triggers an alarm at the first sign of smoke. Thanks to its high- performance forward-scattering reflective response technology, the photoelectric smoke sensor responds quickly and reliably to a wide range of fire types, especially slow burning fires fuelled by combustibles typically found in modern multi-use buildings. Compatibility The KI-PD detector is compatible with Kidde VS and VIM series panels. Testing & Maintenance Each detector automatically identifies when it is dirty or defective and causes a "dirty detector" message. The detector's sensitiv- ity measurement can also be transmitted to the loop controller. A sensitivity report may be printed to satisfy NFPA sensitivity mea- surements, which must be conducted at the end of the first year and every two years thereafter. The user-friendly maintenance program shows the current state of each detector and other pertinent messages. Single detectors may be turned off temporarily from the control panel. Availability of maintenance features is dependent on the fire alarm system used. Accessories Detector mounting bases have wiring terminals that are acces- sible from the "room-side" after mounting the base to the electrical box. The bases mount to North American 1-gang boxes and to 31/2 inch or 4 inch octagon boxes, 11/2 inches (38 mm) deep. They also mount to European BESA and 1-gang boxes with 60.3 mm fixing centers. The Kl-SB4, KI-RB4, and Kl-1B4 mount to North American 4. inch sq. electrical boxes in addition to the above boxes. They include the GSA-TS4 Trim Skirt, which is used to cover the "mounting ears" on the base. The KI-ABST mounts to a 4 inch square box only. KI-ABST/T/LF KI-SB KI-IB KI-RB GSA-LED Audible Base Standard Base Isolator Base Relay Base Remote LED Remote LED GSA-LED - The remote LED connects to the Kl-SB or KI-SB4 Standard Base only. It features a North American size 1-gang plastic faceplate with a white finish and red alarm LED. GSA-TS4 Trim Skirt - Supplied with 4 inch bases, it can also be ordered separately to use with the other bases to help hide surface imperfections not covered by the smaller bases. Sounder Bases - KI Series sounder bases are designed for use where localized or group alarm signaling is required. KI-ABST bases provide sounder capability to KI Series heat and smoke detectors. They are not intended for use with combination carbon monoxide detectors in Fire-plus-CO mode. KI-ABDT bases provide sounder capability to KI Series smoke and heat detectors, as well as carbon monoxide detectors when used with a GSA-T314 Temporal Pattern Generator. KI-ABLT bases provide 520 Hz low frequency sounder capability to KI Series smoke and heat detectors, as well as carbon monoxide detectors when used with a GSA-T3T4 Temporal Pattern Generator. The Kl-ABLT is suitable for ap- plications requiring low frequency audible tones. Installation KI Series detector bases mount to North American 1-gang boxes, 3-1/2 inch or 4 inch octagon boxes, and to 4 inch square elec- trical boxes 1-1/2 inches (38 mm) deep. They mount to European BESA and 1-gang boxes with 60.3 mm fixing centers. See mounting base installation and wiring for more information. Sensing and reporting technology The microprocessor in each detector provides additional benefits - Self-diagnostics and History Log, Automatic Device Mapping, and .Fast, Stable Communication. Self-diagnostics and History Log - Each KI Series detector constantly runs self-checks to provide important maintenance in- formation. The results of the self-check are automatically updated and permanently stored in the detector's non-volatile memory Automatic Device Mapping - The loop controller learns where each device's serial number address is installed relative to other devices on the circuit. The mapping feature provides supervision of each device's installed location to prevent a detector from being reinstalled (after cleaning etc.) in a different location from where it was originally. Fast Stable Communication - On-board intelligence means less information needs to be sent between the detector and the loop controller. Other than regular supervisory polling response, the detector only needs to communicate with the loop controller when it has something new to report. Page 2 of 4 DATA SHEET K85001 -0646 Not to be uted for instaliation purposes. Issue 1 Typical Wiring The detector mounting bases accept #18 AWG (0.75mm2), #16 Audible Sounder Bases, Fire Mode (1 .0mm2), #14 AWG (1 .5mm2), and #12 AWG (2.5mm2) wire sizes. A84G7 AB4G, AB4G-LF sounder bases Sizes #16 AWG (1 .0mm2) and #18 AWG (0.75mm2) are preferred for ease of installation. Standard Detector Base, KI-SB, KI KI-ABOT, © © KI-AB LT: KI-ABST, KI-ABLT: Jumper Cuts Output Mode Default = Fire This is the basic mounting base Remote LED Volume Setting Cut/remove jumper for for Kidde KI Series detectors. Max resistance Default = High Fire plus CO _________ per wire The GSA-LED Remote LED is Cut/remove must not exceed jumper for KI-ABST: supported by this 10 Ohms low dB (10 Tone Setting Base. ri ëN ou - Default = Temporal hTerm Description I I ' mom Cut/remove jumper for I 1 Not Used I Steady 2 DATA IN/OUT (+) I 3 Not Used I I \T -;ttt ../ I 4 DATA IN I-) I ' ij i 0 ________________ _________________ KI-ABDT: Not Used 4 Remote LED -) I DATA i ii I_DATA OUT I-) .7 ___. 5 Remote LEO )+) I 6 Not Used I 7 DATA OUT DATA IN I.) DATA OUT (*) -, 24 Vdc in From Signature Controller To Nest Device From power supply - 24 Vdc out or Previous Device or previous base . . + To nest base or EOL relay Data in - - Data out Isolator Detector Base, KlIB, KI-IB4 From 1<1 Device Controller to nest KI Series device or previous device +) . + This base includes a built-in line fault isolator for use on Class A circuits. A detector must be installed for it to operate. The isolator base does not support the GSA-LED Remote LED. The isolator operates as follo'A - a short on the line causes all lators to open within 23 mse - at 10 msec intervals, beginning on one side of the Class A DA1 circuit nearest the loop controller, the isolators close to provide the DA5- next isolator down the From Signature Controller or Previous Device line with power - when the isolator next to the short closes, it reopens within 10 msec. The process repeats beginning on the other side of the loop controller. Warnings & Cautions This detector does not operate without electrical power. As fires frequently cause power interruption, discuss further safeguards with the local fire protection specialist. This detector does not sense fires in areas where smoke cannot reach the detector. Smoke from fires in walls, roofs, or on the opposite side of closed doors may not reach the detector. Photoelectric detectors have a wide range of fire-sensing capabilities and are best suited for detecting slow, smolder- ing fires. In Canada, install according to CAN/ULC-5524 Standard for the Installation of Fire Alarm Systems, CSA C22.1 Canadian Electrical Code, and the local authority having jurisdiction. OUT (+) To Nest Device OUT (-) Term Description 1 Not Used 2 DATA IN/OUT )+) 3 DATA IN)-) 4 Not Used 5 Not Used 6 DATA OUT 7 Not Used Relay Detector Base, KI-RB, KI-RB4 Noirnofly- Normally- This base includes a relay. Nor- mally Open or Normally Closed operation is selected during installation. The dry contact is rated for 1 amp (pilot duty) © 30 Vdc. The relay's position is supervised to avoid accidentally jarring it out of position. The Kl-RB DAT can be operated as a control relay if programmed to do so at DATA IN (v) DATA OUT tnt the control panel. The relay base From SgvaTure Controller To Next Device or Previous Device does not support the GSA-LED Term Description I t Normally Open I Remote LED. CONTACT RATING 2 DATA IN/OUT )+) I 1,0 Amp st 30 VDC I I 3 Common I Pilot Duty) 4 5 6 7 DATA IN () N I Nor ot Used mally-Closed DATA OUT)-) I Page 3 of 4 C DATA SHEET K85001 -0646 Not to be used for installation purposes. Issue 1 Dimensions INAV ; I idde cJD Technology that saves lives Q Contact us... Email: kiddefire@fsutc.com Web: kidde.com/enginredsystems 1016 Corporate Park Drive Mebane, NC 27302 Kidde is a registered mark in the United States and other countries. © 2018 Walter Kidde Portable Equipment. All rights reserved. Specifications Operating voltage 15.20 to 19.95 VDC Normal operating current '51pA - Alarm current 68 pA3 Smoke Sensitivity Range ULJULC: 0.53 to 3.94 %Ift. (1.7 to 12.35 %/m) obscuration Vibration level 10 to 35 Hz, with an amplitude of aoi in. Air velocity 0 to 4,000 ft/mm (0 to 20 m/s) Wall mounting 12 in. (305 mm) max. from Compatible bases See Ordering Information Compatible detector testers Testifire 1000, Testifire 2000 Operating environment 32 to 120°F (0 to 490C), 0 to 93% RH, noncondensing Construction High Impact Engineering Polymer, White S Storage temperature -4 to 140°F (-20 to 60°C) Environmental compensation Automatic Agency Listings CAN/ULC-S529, UL 268, UL 268A Ordering Information Catalog Description Ship Wt. Number lbs (kg) Kl-PD Intelligent Optical Smoke Detector 0.4(0.16) Accessories Kl-SB - Detector Mounting_Base - Standard Base clw Trim Kl-RB Detector Mounting Base wlRelay Kl-RB4 4-inch Detector Mounting Base wlRelay, clw Trim Skirt 0.2 (.09) KI-IB Detector Mounting Base w/Fault Isolator Kl-IB4 4-inch Detector Mounting Base WI Fault Isolator, clw Trim Skirt GSA LE -D Remo_te Alarm LED (not for EN54 applications) Kl-ABST Audible (Sounder) Base for Fire Detectors 0.3(0.1 Kl-ABLT Low Freauencv Audible (Sounder) Base for CO and Fire Detectors 0.3 (0.1 GSA-TS4 Trim Skirt (supplied with 4-inch bases) 0.1 (0.04) GSA-TS Trim Skirt - (optional for non 4-inch bases) 0.1 (0.04) GSA-DMP Detector Mounting Plate 3.0 (1.4) Page 4oI4 DATA SHEET K85001 -0646 91 Not to be used for installation purposes. Issue 1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1657:0120 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, lnc.8985 Town Center Parkway, Bradenton, FL 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.micochero@carrier.com DESIGN: Detector Bases. Base models are as follow: Models 59638, 5964 B/BR, 624113-002, 624913-001, 6251, 625113-00IA, -001, -002, -003, -004, 6251B-100, -200, -R100, -R200 and 6251-2 Models 6251 B-001, -002, -003 and -004 are suitable for releasing device service. Models P-847674-0022, -0024, -0042, -0043, -0044, -0045, -0046, -0047. Models SIGA-113, -I134, -RB, -RB4, -SB, -SB4 and -AB4. *Models K1-1B, -1B4, -RB, -RB4, -SB and -,SB4. The -RB series are suitable for releasing device service. *Model SIGI-SB and SIGI-SB4. S Model AB4G-SB surface mount back box for use with listee's SIGA series sounder bases. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. *Kl are under the Kidde Brand. SIGA* and SIGI* are under the Edwards Brand APPROVAL: Listed as mounting bases for use with separately listed compatible detectors and fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7300-1591:120 and 7300-1388:170 *Rev 05-03-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other 0 Date Issued July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM IL 11%q LISTING SERVICE LISTING No. 7272-1657:0331 Page 1 of 2 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, lnc.8985 Town Center Parkway, Bradenton, FL 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.micochero@carrier.com DESIGN: Models SIGA-PD, *SIGI..PD *KIpD and *KlR.PD Analog addressable photoelectric smoke detectors.*Model SIGI-PD is similar to Model SIGA-PD except for isolation circuitry. *Model KI-PD is identical to Model SIGA-PD except for trade name. *Model KlR-PD is similar to Model SlGA-PD except for control panel compatibility. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 15.2-19.95 Vdc INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72 and applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. *Models SIGA-PD and SIGI-PD are under the Edwards brand. *Models KI-PD and KlR-PD are under the Kidde brand. APPROVAL: Listed as analog addressable photoelectric smoke detectors. *Model Kl-PD is for use with listee's Models VS1, VS2 and VS4 (CSFM No. 7165-1657:0244); VM-1 (CSFM No. 7165-1657:0309) fire alarm control units. *Models SIGA-PD and SIGI-PD are for use with listee's Models EST3 (CSFM No. 7165-1657:0186); iO64, i0500 and i01000 (CSFM No. 7165-1657:0244); EST3X (CSFM No. 7165-1657:0306) fire alarm control units. *Model KIR-PD is for use with listee's Models FX-64, FX-254 and FX-1000 (CSFM No. 7165-1657:0244) fire alarm control units. *Model SIGA-PD is for use with listee's bases: Models SlGA-SB, -SB4, -RB, -RB4, -IB, -1134 (CSFM No. 7300-1657:0120); SIGA-AB4G (CSFM No. 7300-1657:0222); SIGA-AB4GT (CSFM No. 7300-1657:0307) and SlGA-AB4G-LF (CSFM No. 7300-1657:0322). *Model SlGI-PD is for use with listee's bases; Models SIG$-AB4G (CSFM No. 7300-1657:0222); SIGl-AB4GT (CSFM No. 7300-1657:0307) and SIG[-AB4G-LF (CSFM No. *Rev 02-15-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division Listing No. 7272-1657:0331 Page 2 of 2 7300-1657:0322). *Models KI-PD and KIR-PO are for use with listee's bases; Models KI-ABST (CSFM No. 7300-1657:0222), Kl-ABDT (CSFM No. 7300-1657:0307) and Kl-ABLT (CSFM No. 7300-1657:0322). Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires, which smolder for hours before bursting into flames. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires, which consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. *Rev 02-15-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division / GSA-M270 SERIES S e~ neies ~P~ U Technology that saves lives Manual Pull Stations GSA-M270, GSA-M270 GSA-M278) The GSA-M270 and GSA-M278 series Manual Pull Stations are part of Kidde's Signature Series system. The GSA-M270 Fire Alarm Manual Pull Stations feature our very familiar teardrop shape. They are made from die-cast zinc and finished with red epoxy powder-coat paint complemented by aluminum colored stripes and markings. With positive pull-lever operation, one pull on the station handle breaks the glass rod and turns in a posi- tive alarm, ensuring protection plus fool-proof operation. Presignal models (GSA-M270P) are equipped with a general alarm (GA) keyswitch for applications where two stage operation is required. The up-front highly visible glass rod discourages tampering, but is not required for proper operation. Kidde's double action single stage GSA-M278 station is a contem- porary style manual station made from durable red colored lexan. To initiate an alarm, first lift the upper door marked LIFT THEN PULL HANDLE", then pull the alarm handle. Standard Features Note: Some features described here may not be supported by all control sys- tems. Check your control panel's Installation and Operation Guide for details. Traditional familiar appearance GSA-M270 models feature our familiar teardrop design with simple positive pull action and sturdy die-cast metal body. One stage (GA), two stage (pre-signal), and double action models GSA-M270 models are available for one or two stage alarm systems. The single stage double action GSA-M278 features a rugged Lexan housing with keyed reset mechanism. )- .c.o; I> InteIhç1ont Initiating aq =MP 7' `pnfiF5I:sy—stZr1s dde a @ GSA-M278, 7150-1483: 0139 IVIEA S2318 Break glass operation An up-front visible glass rod on the GSA-M270 discourages tampering. Intelligent device with integral microprocessor All decisions are made at the station allowing lower com- munication speed while substantially improving control panel response time. Less sensitive to line noise and loop wiring properties; twisted or shielded wire is not required. ADA Compliant Meets ADA requirements for manual pull stations. Electronic Addressing with Non-volatile memory Permanently stores programmable address, serial number, type of device, and job number. Automatically updates historic information including hours of operation, last maintenance date, number of alarms and troubles, and time and date of last alarm. Automatic device mapping Each station transmits wiring information to the loop control- ler regarding its location with respect to other devices on the circuit. Stand-alone operation The station inputs an alarm even if the loop controller's polling interrogation stops. Diagnostic LEDs Status LEDs; flashing GREEN shows normal polling; flashing RED shows alarm state. Designed for high ambient temperature operation Install in ambient temperatures up to 120 °F (49 00) Page 1 of 4 DATA SHEET K85001-0279 Not to be used for 'ostallation purposes. Issue 1 Application The operating characteristics of the fire alarm stations are deter- mined by their sub-type code or 'Personality Code". NORMALLY- OPEN ALARM - LATCHING (Pesonality Code 1) is assigned by the factory; no user configuration is required. The device is configured for Class B lDC operation. An ALARM signal is sent to the loop controller when the station's pull lever is operated. The alarm con- dition is latched at the station. Compatibility Signature Series manual stations are compatible only with Kidde's Signature Loop Controller. Warnings & Cautions This device will not operate without electrical power. As fires fre- quently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. Testing & Maintenance To test (or reset) the station simply open the station and operate the exposed switch. The GSA-M270 series are opened with a tool; the GSA-M278 requires the key which is supplied with that station. The station's automatic self-diagnosis identifies when it is defec- tive and causes a trouble message. The user-friendly maintenance program shows the current state of each Signature series device .and other pertinent messages. Single devices may be deactivated temporarily, from the control panel. Availability of maintenance features is dependent on the fire alarm system used. Scheduled maintenance (Regular or Selected) for proper system operation should be planned to meet the requirements of the Authority Having Jurisdiction (AHJ). Refer to current NFPA 72 and ULC CAN/ULC 536 standards. Typical Wiring The fire alarm station's terminal block accepts #18 AWG (0.75mm2) to #12 AWG (2.5mm2) wire sizes. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Wiring Notes Refer to Signature Loop Controller manual for maximum wire distance. 2. All wiring is power limited and supervised. REAR VIEW of 278 F 0 TB2 Red LED 11 I ____________ Green LED (Aldrrn/Actde) I © 2 0 (Normal)) 1 OTB1 4 3 _______ 0 5 DATA IN Tv) >- =— OUT to) 1 DATA IN (-) > DATA OUT C-) From Signature Controller I To Next Device or Previous Device A Figure 4. Single Stage Systems REAR VIEW of 270P, 270PB C3 CM 0 °TE2 Red LED Green LED (uJorm/ActUe) 10 4 (Normal) TBl_______ 0 411D1 5 DATA IN).)) I. DATA OUT 1. DATA IN (-C > DATA OUT C-) From Signature Controller I To Next Device or Previous Device A Figure 5. Two Stage Systems Page 2 of 4 DATA SHEET K85001-0279 Not to be used for installation purposes. Issue 1 Installation Single-stage Signature Series fire alarm manual pull stations mount to North American 21/2 inch (64 mm) deep 1-gang boxes. S Two stage presignal (270P) models require 11/2 inch (38 mm) deep 4-inch square boxes with 1 -gang, ½-inch raised covers. Openings must be angular. Rounded openings are not acceptable. Recommended box: Steel City Model 52-0-13; in Canada, use Iberville Model Cl 52-0-49-1/2. All models include terminals are suited for #12 to #18 AWG (2.5 mm2 to 0.75 mm2) wire size. Kidde recommends that these fire alarm stations be installed according to latest recognized edition of national and local fire alarm codes. Electronic Addressing: The loop controller electronically addresses each manual station, saving valuable time during system com- missioning. Setting complicated switches or dials is not required. Each station has its own unique serial number stored in its on-board memory. The loop controller identifies each device on the loop and assigns a soft" address to each serial number. If desired, the stations can be addressed using the SIGA-PRO Signature Program/Service Tool. Key-Latch Compatible Electrical Box Cover Compatible Electrical Box Release Cover J Release— Screw M C Toggle Toggle I Back 0 Back Plate plate CP Switch Switch Glass Rod __4 - - Glass Rod - - - - - - Release Lever OPENn Figure 1QSA-M278Hnstallation Figure 2. GSA-M270 installation Cover Release (:1111:) \, 4 -fible Electrical Roe - - with ½-inch raised covers Toggle il loss Rod Release Le~vfL Figure 3. GSA-M270P installation C Page 3 of 4 DATA SHEET K85001-0279 Not to be used for Installation purposes. Issue 1 Technology that saves lives Contact us... Email: kidde.fire@fs.utc.com Web: kidde.com/engineeredsystems 1016 Corporate Park Drive Mebane, NC 27302 Kidde is a registered mark in the United States and other Countries. © 2018 Walter Kidde Portable Equipment. All rights reserved. Specifications Catalog Number GSA-M270 i GSAM270P, GM78 Description Single Action j Single Action -Two Double Action - One Stage Stage (Presignal) - One Stage Addressing Uses 1 Module Uses 2 Module Uses 1 Module Requirements Address Addresses Address Operating Current Standby = 250pA - Standby = 396lJA Standby=25OlJA, Activated = 400lJA Activated = 680pA tActivated = 400pA Construction & Finish Diecast Zinc - Red Epoxy Lexan - Red with with aluminum markings white markings Type Code Factory Set Operating Voltage 15.2 to 19.95 Vdc (19 Vdc nominal) Storage and Operating Operating Temperature: 32°F to 120°F (0°C to 49°C) Environment Storage Temperature: -4°F to 140°F (-20°C to 60°C) Humidity: 0 to 93% RH LED Operation On-board Green LED - Flashes when polled On-board Red LED - Flashes w hen in alarm Compatibility Use With: Signature Loop Controller Agency Listings UL, ULC, MEA,CSFM,FM Ordering Information Ship Catalog Wt. lbs Number Description (kg) GSA-M270 One Stage Fire Alarm Station, English Markings - UL/ULC Listed S GSA-M270P Two Stage (Presignal) Fire Alarm Station, English Markings 1 (0.5) - ULJULC Listed GSA-7 Double Action (One Stage) Fire Alarm Stabon, English Markings - UL/ULC Listed Accessories 270-GLR 20 Glass Rods - for GSA-M270 series (USA ONLY) 276-GLR -- 20 Glass Rods - for GSA-M278 series S Page 4of4 DATA SHEET K850010279 Not to be used for installation purposes. Issue 1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. CATEGORY: LISTEE: DESIGN: INSTALLATION: MARKING: APPROVAL: 7150-1483:0139 Page 1 of 1 7150-- FIRE ALARM PULL BOXES MIRTONE*8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com Models GSA-M270 and GSA-M270P and 6SA-M278'non-coded, intelligent manual pull stations. Unit consists of a listed pull station and a remote transponder. Refer to listee's data sheet for additional detailed product description and operational considerations. In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listees name or Edwards, Edwards Systems Technology (EST), model number, electrical rating and UL label. Listed as manual pull stations for use with separately listed compatible fire alarm control units. S These manual pull boxes meet* the requirements of UL Standard 38, 1999 Edition and California amendments. NOTE: FORMERLY: 7150-1388:194 XLF: 7150-1657:0129 *Corrected 03-17-15 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division K 0 111 ol coj, (e Technology that saves lives Tq Out"put Module mccis ELECTRON I f, j R1 S3424 3 7300-1483: 0115 4 I -MEA !- GSA-CC1 S and MCC1 S Synchronization Output Modules are intelligent analog addressable devices that form part of Kidde's Signature line of products. The actual operation of the GSA-CC S and MCC1 S is determined by the 'personality code" selected by the installer, which is downloaded to the module from the Signa- ture loop controller during system configuration. Depending on their assigned personality, Synchronization Output Modules may be used as a signal power riser selector to provide synchronization of fire alarm signals across multiple zones, or for connecting, upon command from the loop controller, supervised Class B signal or telephone circuits to their respective power inputs. The poyer inputs may be polarized 24 Vdc to operate au- dible and visible signal appliances or 25 and 70 VPMS to operate audio evacuation speakers and firefighter's telephones. Standard Features Provides UL 1971-compliant auto-sync output for visual signals Use for connecting a supervised output circuit to a supervised 24 Vdc riser input and synchronizing multiple notification appli- ance circuits. Functions as an audible signal riser selector Use as a synch module or for connecting supervised 24 Vdc AudibleNisible signal circuits, or 25 and 70 VRMS Audio Evacuation and Telephone circuits to their power inputs. Built-in ring-tone generator When configured for telephone circuits, the GSA-CC1 S gener- ates its own ring-tone signal, eliminating the need for a sepa- rate ring-tone circuit. Automatic device mapping Signature modules transmit information to the loop controller regarding their circuit locations with respect to other Signature devices on the wire loop. Electronic addressing Programmable addresses are downloaded from the loop con- troller, a PC, or the SIGA-PRO Signature Program/Service Tool; there are no switches or dials to set. Intelligent device with microprocessor All decisions are made at the module to allow lower com- munication speed with substantially improved control panel response time and less sensitivity to line noise and loop wiring properties; twisted or shielded wire is not required. C '- K85001-0543 Not toOo used -. In purposes. Issue 1.1 fl nstal}ation • The GSA-CC1S mounts to a standard North American two-gang electrical box, making it ideal for locations where only one module is required. Separate I/O and data loop connections are made to each module. The GSA-MCCIS is part of the UIO family of plug-in Signature Series modules. It functions identically to the GSA-CC 5, but takes advantage of the modular flexibility and easy installation that characterize all UIO modules. Two- and six-module UIO mother- boards are available. These can accommodate individual risers for each on-board module, or risers that are shared by any combina- tion of its UIO modules. All wiring connections are made to termi- nal blocks on the motherboard. UIO assemblies may be mounted in Kidde enclosures. Personality Codes The operation of the GSA-CC S is determined by their sub-type code or Personality Code". The code is selected by the installer depending upon the desired application and is downloaded from the loop controller. Personality Code 5: Signal Power or Audio Evacuation (sin- gle riser), Configures the module for use as a Class B Audible! Visible Signal power (24 Vdc polarized) or Audio Evacuation (25 or 70 VRMS) power selector. The ring-tone generator is disabled. The output circuit is monitored for open or shorted wiring. If a short exists, the control panel inhibits the activation of the audible/ visible signal circuit to prevent connection to the power circuit. Personality Cede 6: Telephone with ring-tone (single riser). • Configures the module for use as a Telephone power selector. When a telephone handset is plugged into its jack or lifted from its hook, the module generates its own Ring-Tone signal. A separate ring-tone circuit is not needed. The module sends this signal to the control panel to indicate that an off-hook condition is present. When the system operator responds to the call, the ring-tone signal is disabled. Personality Code 25: Visual Signal Synchronization. This personality code configures the module to provide synchronization of fire alarm signals across multiple zones. It functions as a signal power (24 Vdc) riser selector. The output wiring is monitored for open circuits and short circuits. A short circuit will cause the fire alarm control panel to inhibit the activation of the audible/visual signal circuit so the riser is not connected to the wiring fault. Warnings & Cautions This module will not operate without electrical power. As fires fre- quently cause power interruption, we suggest you discuss further safeguards with your fire protection specialist. Kidde recommends that these modules be installed according to latest recognized edition of national and local fire alarm codes. Compatibility These modules are part of Kidde's Signature Series intelligent pro- cessing and control platform. They are compatible with VM, and VS Series control panels. The GSA-CC1S: mounts to North American 2-1/2 inch (64 mm) deep 2-gang boxes and 1-1/2 inch (38 mm) deep 4 inch square boxes with 2-gang covers and GSA-MP mounting plates. The terminals are suited for #12 to #18 AWG (2.5 mm2 to 0.75 mm2) wire size. GSA-MCC1S: mount the UlOxR motherboard inside a suitable Kidde enclosure with screws and washers provided. Plug the module into any available position on the motherboard and secure the module to the motherboard with the captive screws. Wiring connections are made to the terminals on the motherboard (see wiring diagram). UlOxR motherboard terminals are suited for #12 to #18 AWG (2.5 mm2 to 0.75 mm2) wire size. UIO Motherboard 6-32 j Self-tapping screws ----------- Plug-in Module E screws #6 Flat washers Cabinet or electrical enclosure Electronic Addressing The loop controller electronically addresses each module saving valuable time during system commissioning. Setting complicated switches or dials is not required. Each module has its own unique serial number stored in its "on-board memory". The loop control- ler identifies each device on the loop and assigns a "soft" address to each serial number. If desired, the modules can be addressed using the SIGA-PRO Signature Program/Service Tool. Testing & Maintenance The module's automatic self-diagnosis identifies when it is defec- tive and causes a trouble message. The user-friendly maintenance program shows the current state of each module and other perti- nent messages. Single modules may be turned off (de-activated) temporarily, from the control panel. Scheduled maintenance (Regular or Selected) for proper system operation should be planned to meet the requirements of the Authority Having Jurisdiction (AHJ). Refer to current NFPA 72 and ULC CAN/ULC 536 standards. Page 2 of 4 ORn313re 1____ circu 0313 Out - MIS 00 Typical Wiring GSAcci8 (Standard Mount) Personality Codes Typical Speaker Cir cuit ULIULC Listed 47K0hnsE0L Personality Typical Telephone Circuit Code 6 B r3m L/U ULC Listed III, OhrnEOL Personality Enhanced Integrity and Genesis Devices Code 25 ULJULC Listed 47KOhrn E01- GSA-MCC1S (UIO Mount) Code 5 UL/ULC Listed Personality Typical Speaker Cir cuit 47K Ohm EOL Personality Typical Telephone Circuit Code 6 ULJULC Listed 47KOlmfl, EOL rDa B Personality Enhanced Integrity and Genesis Devices ULJULC Listed SZ Y" 47K Ohm EOL Code 25 1234 liioliR) series nsothesboar Riser i Out Riser In Green LEO INorerol I To next device 2 Riser out 1+) Red LEO lvusiuel Riser out Data out 1+1 Riser in 1+) From control Far— Riser in I-) ) To n2e3 device or EOL r esistor. Data out I-) - Data in (+) Front Signature consrnuer Data in (-) or Previous Device S _l Riser sir ! i_= Riser I Out Multiple CC1(S) modules using the MIRBPS's sense inputs TB10 Notification appliance circuit (NAC) NAC1/ - AUX1 UL listed EOL 15KOhms T TIIjZ jJIj - - NAC2/ +Ij AUX2 Notification appliance circuit (NAC) NAC31 -4- UL listed - AUX3 - EOL 15 KOhms - NAC4/ + AUX4 - 200 mAAUX Continuous lN - M = Sense 1 COM t OUT lN EOL 47 K 11 Eff Sense2COM OUT D-EOL 47K 1+ _I NO Trouble COM _____ Ii iii F 109 109 NC T 0 CCI(S) module CC1(S) module 00 00 [3] Page 3 of 4 DATA SHEET K85001-0543 Not to be used for installation purposes. Issue ti Specifications Catalog Number jGSCTj North American 21/2 inch (64 mm) deep two-gang boxes and 11/2 Mounting inch (38 mm) deep 4 inch square boxes with 2-gang covers and GSA-MP mounting plates GSA-MCC1 S Plugs into U102R, U106R or U106 Motherboards Output Module Type Code 50 (factory Address Requirements Uses one module address to #18 AWG (2.5 mm2 to 0.75mm2) Standby = 223IJA Activated = 100jA' 11 15.2 to 19.95 Vdc (19 Vdc nominal) 24 Vdc = 2 amps Output Rating 25 V Audio = 50 watts I 70 V Audio = 35 watts 7!Qdde [iOL1y tii ssves lives Contact us... Email: kidde.fire@fs.utc.com Web: kidde.corn/engineeredsysterns 1016 Corporate Park Drive Mebane, NC 27302 Kidde is a registered mark in the United States and other countries. © 2018 Walter Kidde Portable Equipment, All rights reserved. Terminations I Suitable for #12 Operating Current High Impact Engineering Polymer Operating: 32°F to 120°F (0°C to 49°C) Storage: -4°F to 140°F (-20°C to 60°C) Humidity: 0 to 93% RH LED Operation I Green LED - Flashes when polled Red LED - Flashes when in alarm! active Use with: Signature Loop Controller UL, ULC, CSFM, MEA 0 Ordering Information Catalog Description Shipping Wt. Number lbs (kg) GSA-CC1S Synchronization Output Module (Standard Mount) - UL/ULC Listed 0.5 (0.23) GSA-MCC1S Synchronization Output Module )UIO Mount) - UL/ULC Listed 0.18(0.08) Related Equipment 27193-21 Surface Mount Box - Red, 2-gang 2(1.2) 27193-26 Surface Mount Box - White 2 GSA-UI02R Universal Input-Output Module Board w/Riser Inputs 0 32 0 15 - Two Module Positions GSAUI06R Universal Input-Output Module Board w/Riser Inputs 0 62 0 28 - Six Module Positions _______ GSA-U106 Universal Input-Output Module Board - SixModule Positions 0.56 (0.25) 235196P Bi-polarTransientProtector 0.b MFC-A Multifunction Fire Cabinet - Red, 7.0(3.1) supportsSignature Module Mounting Plates GSA-MP1 Signature Module MountingPlate,1footprint 1.5 (0.70) GSA-MP2SignatureModule MountingPlate,1/2footprint 0.5 (0.23) GSA-MP2L SignatureModuleMountingPlate, 1/2 extended footprint 1.02 Page 4 of 4 DATA - K850010543 Net to he use-: aI 1 .. Issue 1,1 Construction Storage and Operating Environment KIDDEr'' Da'nk ' Intefligent Input/Output Q[tUth 41i 1 S Technology that saves lives Control Relay Modules Overview The Control Relay Module and the Polarity Reversal Relay Module are part of the Signature Series system. They are intelligent analog addressable devices available in either plug-in (UlO) versions, or standard 1 -gang mount versions. The GSA-CR/MCR Control Relay Module provides a Form C" dry relay contact to control external appliances such as door clos- ers, fans, dampers etc. This device does not provide supervision of the state of the relay contact. Instead, the on-board micro- processor ensures that the relay is in the proper ON/OFF state. Upon command from the loop controller, the GSA-CR/MCR relay activates the normally open or normally-closed contact. The GSA-CRR/MCRR Polarity Reversal Relay Module provides a Form "C" dry relay contact to power and activate a series of GSA-AB4G Audible Sounder Bases. Upon command from the Signature loop controller, the GSA-CRR reverses the polarity of its 24 Vdc output, thus activating all Sounder Bases on the data loop. Standard-mount versions (GSA-CR and GSA-CRR) are installed to standard North American 1-gang electrical boxes, making them ideal for locations where only one module is re- quired. Separate I/O and data loop connections are made to each module. Plug-in UIO versions (GSA-MCR and GSA-MCRR) are part of the UIO family of plug-in Signature Series modules. They function identically to the standard mount versions, but take advantage of the modular flexibility and easy installation that characterizes all UIO modules. Two- and six-module UIO motherboards are avail- able. All wiring connections are made to terminal blocks on the motherboard. UIO assemblies may be mounted in Kidde enclo- sures. 7300-1483: 01 5 * GSA-CR GSA MCR S3424 Standard Features Provides one no/nc contact (GSA-CR/MCR) Form "C" dry relay contact can be used to control external ap- pliances such as door closers, fans, dampers etc. Allows group operation of sounder bases The GSA-CRR/MCRR reverses the polarity of its 24 Vdc out- put, thus activating all Sounder Bases on the data loop. Plug-in (UIO) or standard 1-gang mount UIO versions allow quick installation where multiple modules are required. The 1-gang mount version is ideal for remote locations that require a single module. Automatic device mapping Signature modules transmit information to the loop controller regarding their circuit locations with respect to other Signature devices on the wire loop. Electronic addressing Programmable addresses are downloaded from the loop con- troller, a PC, or the SIGA-PRO Signature Program/Service Tool; there are no switches or dials to set. Intelligent device with microprocessor All decisions are made at the module to allow lower com- munication speed with substantially improved control panel response time and less sensitivity to line noise and loop wiring properties; twisted or shielded wire is not required. Ground fault detection by address Detects ground faults right down to the device level. Page 1 of 6 DATA SHEET K85001-0239 Not to be used for installation purposes. Issue 1 Application The operation of Signature Series control relays is determined by their sub-type code or 'Personality Code." Personality Code 8: CONTROL RELAY (GSACR/MCR) - Dry Contact Output. This setting configures the module to provide one Form "C" DRY RELAY CONTACT to control Door Closers, Fans, Dampers, etc. Contact rating is 2.0 amp @ 24 Vdc; 0.5 amp @ 120 Vac (or 0.25A @ 220 Vac for non-UL applications). Personality Code 8 is assigned at the factory. No user configura- tion is required. GSA-CR and GSA-CRR: modules mount to North American 21/2 • inch (64 mm) deep 1-gang boxes and 11/2 inch (38 mm) deep 4 inch square boxes with 1-gang covers and GSA-MP mounting plates. The terminals are suited for #12 to #18 AWG (2.5 mm2 to 0.75 mm2) wire size. Compatible electrical box Personality Code 8: POLARITY REVERSAL RELAY MODULE (GSA-CRR/MCRR). This setting configures the module to reverse Wall plate, white the polarity of its 24 Vdc output. Contact rating is 2.0 amp @ 24 (1-gang) Vdc (pilot duty). Personality Code 8 is assigned at the factory. No user configuration is required. Compatibility These modules are part of Kidde's Signature Series intelligent pro- cessing and control platform. They are compatible with VM, and VS Series control panels. LED viewing ports •\ LL1115 ¶ GSA-MCR and GSA-MCRR: mount the UIO motherboard inside a suitable Kidde enclosure with screws and washers provided. Plug the module into any available position on the motherboard and secure the module to the motherboard with the captive Sscrews. Wiring connections are made to the terminals on the motherboard (see wiring diagram). UlO motherboard terminals are suited for #12 to #18 AWG (2.5 mm2 to 0.75 mm2) wire size. UIO Motherboard 532 / - Self-topping / screws i Module screws #6 Flat washers L.j - Cabinet or electrical enclosure Electronic Addressing - The loop controller electronically ad- dresses each module, saving valuable time during system com- missioning. Setting complicated switches or dials is not required. Each module has its own unique serial number stored in its on- board memory. The loop controller identifies each device on the loop and assigns a "soft" address to each serial number. If desired, the modules can be addressed using the SIGA-PRO Signature Program/Service Tool. Kidde recommends that this module be installed according to lat- est recognized edition of national and local fire alarm codes. 1] Warnings & Cautions This module will not operate without electrical power. As fires fre- quently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. Testing & Maintenance The module's automatic self-diagnosis identifies when it is defec- tive and causes a trouble message. The user-friendly maintenance program shows the current state of each module and other per- tinent messages. Single modules may be turned off (deactivated) temporarily, from the control panel. Availability of maintenance features is dependent on the fire alarm system used. Scheduled maintenance (Regular or Selected) for proper system operation should be planned to meet the requirements of the Authority Hav- ing Jurisdiction (AHJ). Refer to current NFPA 72 and ULC CAN/ ULC 536 standards. III I DATA IN(+) 1 DATA IN(-) From Signature or Previous I GSA-CR Control Relay [iJ Typical Wiring Modules will accept #18 AWG (0.75mm2), #16 (1.0mm2), #14 AWG (1.50mm2) and #12 AWG (2.5mm2) wire sizes. Note: Sizes #16 AWG (1 .0mm2) and #18 AWG (0.75mm2) are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Normally- Normally- Open Common Closed S Normally Open Common Normally Closed j 1234 Data lrl + (i\ II 3 + Data Out Green LED (Normal) Red LED lActive) Green LED (Normal) Notes \ Refer to Signature Loop Controller Installation AOUT Sheet for wiring specifications. (+) NFPA 72 requires that the GSA-CR/GSA-MCR A OUT (-) ) be installed in the same room as the device it is ext Device controlling. This requirement may not apply in all markets. Check with your local AHJ for details. The GSA-U106R and the GSA-U102R do not come with TB14. The GSA-Ul06 does not come with TB8 through TB13. A Supervised and power-limited. If the source is nonpower-limited, maintain a space of 1/4 inch from power-limited wiring or use FPL, FPLP, FPLR, or an equivalent in accordance with the National Electrical Code. 7) Maximum #12 AWG (2.5mm2) wire. Mm. #18 (0.75mm2). II I/ II (( TB7 \) .,1Y TB14 \ No connections required for yMCR. Other modules may require connections. 00 - _00 1234 No connections required for MCR. Other modules may require connections. GSA-MCR Control Relay Page 3 of 6 DATA SHEET K85001-0239 Not to be used for estallation purposes. Issue 1 MCRR LIlO(e) series motherboard No connections required for MCRR. Other modules may require Connections. Green LED (Normal) Red LED IActieel _1 No connections required for MCRR. Other modules may require connections. No connections required for MCRR. Other modules may require connections. AA Data Out + Data Circuit Data In VIA Green LED Normall Red LED lActivel Optional MCRR or 11CR for disabling/disconnecting an audible base. Typical Wiring Modules will accept #18 AWG (0.75mm2), #16 (1.0mm2), #14 AWG (1.50mm2) and #12 AWG (2.50mm2) wire sizes. S Note: Sizes #16 AWG (1 .0mm2) and #18 AWG (0.75mm2) are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. A134G AB413 A134G Audible Base Audible Base Audible Base 0 - 0 0 Audible 0 5 - Buses 2 ruin 000 I • 6254A.003 EOL Relay - required for supevision Signature — Data Data Out Circuit UL/ULC Listed 24 Vdc power — supply or —— I_t 1234 Listed 24 VDC Nominal Powet Suppl Signature Controller sounder base GSA-MCRR GSA-CRR Schematic GSA-MCRR Schematic POwer In Power Our IClarry reverses - - Owen Activated S 8Z5 4321 Notes Refer to the Signature controller installation sheet for wiring. One Pair of Wires (24 Vdc power). One Pair of Wires (Signature Data). Single Wire (24 Vdc power). The GSA-UI06R and the GSA-U102R do not come with TB14. The GSA-Ul06 does not come with T138 through A Supervised and power-limited. 8 If the source is nonpower-limited, maintain a space of 1/4 inch from power-limited wiring or use FPL, FPLP, FPLR, or an equivalent in accordance with the National Electrical Code. 9 Maximum #12 AWG (2.5 mm2 ) wire: Minimum #18 AWG (0.75 mm2 ). 10 End-of-Line Relay must monitor and report power supply trouble to control panel. 11 Class B Data wiring may be 'T-tapped' S Page 4 of 6 DATA SHEET K85001-0239 Not to be Used for installation purposes, issue 1 Specifications Catalog Number &C1 J GSA-MCR I GSA-CAR GSA-MCRR, S Description Control Relay Polarity Reversal Relay Type Code Personality Code 8(Factory Set) * Personality Code 8 (Factory Set) Address Requirements Uses 1 Module Address Operating Current Standby = 75 pA Activated =75fJA Operating Voltage 15.2 to 19.95 Vdc (19 Vdc nominal) Relay Type and Rating Form C, 2 Amps @ 24 Vdc (pilot duty), 0.5 Amps © 120 Vac and 0.25 Amps © 220 Vac (220 Vac is non-UL). Not rated for capacitive loads. Mounting North American 2½ inch Plugs into U102R, U106R or North American 21/2 inch Plugs into U102R, U106R or (64 mm) deep 1-gang boxes U106 Motherboards (64 mm) deep 1-gang boxes U106 Motherboards and 11/2 inch (38 mm) deep and 11/2 inch (38 mm) deep 4 inch square boxes with 4 inch square boxes with 1-gang covers and GSA-MP 1-gang covers and GSA-MP mounting plates .. mounting plates Construction & Finish High Impact Engineering Polymer Storage and Operating Operating Temperature: 32°F to 120°F (0°C to 49°C) Environment Storage Temperature: -4°F to 140°F (-20°C to 60°C) Humidity: 0 to 93% RH LED Operation On-board Green LED - Flashes when polled On-board Red LED - Flashes when in alarm/active Compatibility Use With: Signature Loop Controller Agency Listings UL, ULC, CSFM, MEA Ordering Information Catalog Number Description Weight - lbs pton (kg) GSA;C Control Relay Module (Standard Mount) 0.4(0.15) S GSA-MCR Control Relay Module (UIO Mount) ______ 0.18(0.08) GSA-CRR Polarity Reversal Relay Module (Standard Mount) 0.4 (0.15) GSA-MCRR Polarity Reversal Relay Module (UIO Mount) 0.18(0.08) = 27193-11 Surface Mount Box - Red, 1-gang i (0.6) 27193-16 Surface Mount Box - White, 1-gang 1 (0.6) GSA-U102R Universal Input-Output Module Board w/Riser Inputs - Two Module Positions 0.32 (0.15) GSA-U106R Universal Input-Output Module Board w!Riser Inputs - Six Module Positions - 0.62 (0.28) GSA-U106 Universal Input-Output Module Board - Six Module Positions 0.56 (0.25) GSA-AB4G Audible (Sounder) Detector Base 0.3(0.15) Accessories MFC-A Multifunction Fire Cabinet - Red, supports Signature Module Mounting Plates 7.0(3.1) GSA-MB4 Transponder Mounting Bracket (allows for mounting two 1-gang modules in a 2-gang box) 0.4 (0.15) GSA-MP1 Signature Module Mounting Plate, 1 footprint 1.5 (0.70) GSA-MP2 Signature Module Mounting Plate, 1/2 footprint 0.5 (0.23) GSA-MP2L Signature Module Mounting Plate, 1/2 extended footprint 1.02 (0.46) Page 5of6 DATA SHE K85001-0239 Not to be used for than purposes. Issue 1 Signature Series Overview 7 fl( The Signature Series intelligent analog-addressable system from Kidde is an entire family ' ll'Uti.,LJJ of multi-sensor detectors and mounting bases, multiple-function input and output mod- %V C15 J ules, network and non-network control panels, and user-friendly maintenance and service lochno:oay that saves lives tools. Analog information from equipment connected to Signature devices is gathered and converted into digital signals. An onboard microprocessor in each Signature device Contact us. measures and analyzes the signal and decides whether or not to input an alarm. The mi- Emaii: kidde.flre@fs.utc.com croprocessor in each Signature device provides four additional benefits - Self-diagnostics Web: kidde.com/engineeredsystems and History Log, Automatic Device Mapping, Stand-alone Operation and Fast, Stable 1016 corporate Park Drive Communication. Mebane, NC 27302 Self-diagnostics and History Log - Each Signature Series device constantly runs self- Kidde is a registered mark in the United States checks to provide important maintenance information. The results of the self-check are and other countries, automatically updated and permanently stored in its non-volatile memory. This information © 2018 Waiter Kidde Portable Equipment. is accessible for review any time at the control panel, PC, or using the SIGA-PRO Signa- At rights reserved, ture Program/Service Tool. The information stored in device memory includes: Device serial number, address, and type Time and date of last alarm Most recent trouble code logged by the detector - 32 possible trouble codes may be used to diagnose faults. Automatic Device Mapping —The Signature Data Controller (SDC) learns where each device's serial number address is installed relative to other devices on the circuit. The SDC keeps a map of all Signature Series devices connected to it. The Signature Series Data Entry Program also uses the mapping feature. With interactive menus and graphic support, the wired circuits between each device can be examined. Layout or "as-built" drawing information showing branch wiring (1-taps), device types and their address are stored on disk for printing hard copy. This takes the mystery out of the installation. The preparation of as-built drawings is fast and efficient. Device mapping allows the Signature Data Controller to discover: Unexpected additional device addresses Missing device addresses Changes to the wiring in the circuit. Most Signature modules use a personality code selected by the installer to determine their actual function. Personality codes are downloaded from the SDC during system configu- ration and are indicated during device mapping. Standalone Operation - A decentralized alarm decision by the device is guaranteed. Onboard intelligence permits the device to operate in standalone (degrade) mode. If Sig- nature loop controller CPU communications fail for more than four seconds, all devices on that circuit go into standalone mode. The circuit acts like a conventional alarm receiving circuit. Each Signature device on the circuit continues to collect and analyze information from its slave devices. When connected to a panel utilizing standalone operation, modules with their "personality" set as alarm devices (IDC) will alarm should their slave alarm-initiat- ing device activate. Page 6 of 6 DATA SHEET K85001-0239 Not to be used for installation purposes. Issue 1 K )DE 0u1u'oj " intolligent Input Output Ko' d d (a ( D DRES SING Technology that saves lives Input Modules GSA-CT1) GSA-GIl HT, GSA-CT2 GSA-MCT2 MEA * ' I 7300-1483: 0115 t I GSA-CT1/21 o _ r GSA-MCT2 S3424 Standard Features The GSA-CT1 Single Input Module, GSA-Oil HT High Tempera- ture Single Input Module and GSA-0T2/GSA-MOT2 Dual Input Modules are intelligent analog addressable devices used to con- nect one or two Class B normally-open Alarm, Supervisory, or Monitor type dry contact Initiating Device Circuits (IDO). The actual function of these modules is determined by the "personal- ity code" selected by the installer. This code is downloaded to the module from the Signature loop controller during system configura- tion. The input modules gather analog information from the initiating devices connected to them and convert it into digital signals. The module's on-board microprocessor analyzes the signal and decides whether or not to input an alarm. The GSA-Cu, GSA-CT1HT and GSA-C12 mount to standard North American 1-gang electrical boxes, making them ideal for lo- cations where only one module is required. Separate I/O and data loop connections are made to each module. The GSA-0T1 HT module operates at an expanded temperature range of 32 OF to 158 OF (0 00 to 70 00) for those applications requiring more extreme environmental temperature variation. The GSA-MCT2 is part of the UIO family of plug-in Signature Series modules. It functions identically to the GSA-0T2, but takes advantage of the modular flexibility and easy installation that characterizes all UIO modules. Two- and six-module UIO mother- boards are available. All wiring connections are made to terminal blocks on the motherboard. UIO assemblies may be mounted in Kidde enclosures. Multiple applications Including Alarm, Alarm with delayed latching (retard) for water- flow applications, Supervisory, and Monitor. The installer selects one of four "personality codes" to be downloaded to the mod- ule through the loop controller. GSA-CTI HI rated for high temperature environments Suitable for attic installation and monitoring high temperature heat detectors. Plug-in (UIO) or standard 1-gang mount UIO versions allow quick installation where multiple modules are required. The 1-gang mount version is ideal for remote loca- tions that require a single module, Automatic device mapping Signature modules transmit information to the loop controller regarding their circuit locations with respect to other Signature devices on the wire loop. Electronic addressing Programmable addresses are downloaded from the loop con- troller, a P0, or the Signature Program/Service Tool. There are no switches or dials to set. Ground fault detection by address Detects ground faults right down to the device level. 0 Page 1 044 DATA SHEET K85001-0241 Not to be used for installation purposes. Issue 1 Signature Series Overview The Signature Series intelligent analog-addressable system from • Kidde Security is an entire family of multi-sensor detectors and mounting bases, multiple-function input and output modules, network and non-network control panels, and user-friendly mainte- nance and service tools. Analog information from equipment con- nected to Signature devices is gathered and converted into digital signals. An onboard microprocessor in each Signature device measures and analyzes the signal and decides whether or not to input an alarm. The microprocessor in each Signature device pro- vides four additional benefits - Self-diagnostics and History Log, Automatic Device Mapping, and Fast, Stable Communication. Self-diagnostics and History Log - Each Signature Series device constantly runs self-checks to provide important mainte- nance information. The results of the self-check are automatically updated and permanently stored in its non-volatile memory. This information is accessible for review any time at the control panel, PC, or using the Signature Program/Service Tool. Automatic Device Mapping —The Signature Data Control- ler (SDC) learns where each device's serial number address is installed relative to other devices on the circuit. The SDC keeps a map of all Signature Series devices connected to it. The Signature Series Data Entry Program also uses the mapping feature. With interactive menus and graphic support, the wired circuits be- tween each device can be examined. Layout or "as-built" drawing information showing branch wiring (I-taps), device types and their address are stored on disk for printing hard copy. Installation GSA.-CTI, GSA-CT1 HT and GSA-CT2: modules mount to North SAmerican 21/2 inch(64 mm) deep 1-gang boxes and 11/2 inch (38 mm) deep 4 inch square boxes with 1-gang covers and GSA-MP mounting plates. The terminals are suited for #12 to #18 AWG (2.5 mm' to 0.75 mrire size. Compatible electrical box Wall plate, white (1-gang) LJIO Motherboard 6-32 Self-tapping screws [Plug-in ~(UIO) >Capfi Module screws 46 Flat washers —Cabinet or electrical enclosure Electronic Addressing - The loop controller electronically ad- dresses each module, saving valuable time during system com- missioning. Setting complicated switches or dials is not required. Each module has its own unique serial number stored in its on-board memory. The loop controller identifies each device on the loop and assigns a "soft" address to each serial number. If desired, the modules can be addressed using the Signature Pro- gram/Service Tool. Kidde recommends that this module be installed according to lat- est recognized edition of national and local fire alarm codes. Application The duty performed by the GSA-CT1 and GSA-CT2/MCT2 is de- termined by their sub-type code or "Personality Code". The code is selected by the installer depending upon the desired application and is downloaded from the loop controller. One personality code can be assigned to the GSA-CT1. Two per- sonality codes can be assigned to the GSA-CT2/MCT2. Codes 1, 2, 3 and 4 can be mixed on GSA-CT2/MCT2 modules only. For example, personality code 1 can be assigned to the first address (circuit A) and code 4 can be assigned to the second address (circuit B). NORMALLY-OPEN ALARM - LATCHING (Personality Code 1) - Assign to one or both circuits. Configures either circuit A or B or both for Class B normally open dry contact initiating devices such as Pull Stations, Heat Detectors, etc. An ALARM signal is sent to the loop controller when the input contact is closed. The alarm condition is latched at the module. LED viewing ports-4—I 1115 GSA-MCT2: mount the UIO motherboard inside a suitable Kidde enclosure with screws and washers provided. Plug the GSA- MCT2 into any available position on the motherboard and secure the module to the motherboard with the captive screws. Wiring connections are made to the terminals on the motherboard (see wiring diagram). UlO motherboard terminals are suited for #12 to #18 AWG (2.5 mm2 to 0.75 mm2) wire size. Page 2 of 4 NORMALLY-OPEN ALARM - DELAYED LATCHING (Person- ality Code 2) - Assign to one or both circuits. Configures either circuit A or B or both for Class B normally-open dry contact initiat- ing devices such as Waterflow Alarm Switches. An ALARM signal is sent to the loop controller when the input contact is closed for approximately 16 seconds. The alarm condition is latched at the module. NORMALLY-OPEN ACTIVE - NON-LATCHING (Personality Code 3) - Assign to one or both circuits. Configures either circuit A or B or both for Class B normally-open dry contact monitoring input such as from Fans, Dampers, Doors, etc. An ACTIVE signal is sent to the loop controller when the input contact is closed. The active condition is not latched at the module. NORMALLY-OPEN ACTIVE - LATCHING (Personality Code 4) - Assign to one or both circuits. Configures either circuit A or B or both for Class B normally open dry contact monitoring input such as from Supervisory and Tamper Switches. An ACTIVE signal is sent to the loop controller when the input contact is closed. The active condition is latched at the module. DATA SHEET K850010241 Not to be used for instadalion purposes. Issue 1 5 DATA IN (+)> DATA OUT (+) 1 DATA IN)-)> I DATA From Signature Controller To Next Device or Previous Device TVPid No IrritAting Deuce InpetO i -_j -__17tL! JUL, ,4 T1 uioii ef Oct kT.5 rteccnnecwn neqcned to, Nlxoeennne 1requred (en MCTP. GSA-MCT2 uL/ULC Listed 47(0.0(01 ::: Green LEO lNxmolI Red LED (Active) Typical Wiring Modules will accept #18 AWG (0.75mm2), #16 (1 .0mm2), and #14AWG (1.50mm2), and #12 AWG (2.50mm2) wire sizes. S Note: Sizes #16 AWG (1.0mm2) and #18 AWG (0.75mm2) are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Initiating (Slave) Device Circuit Wire Specifications Maximum Allowable Wire Resistance 50 ohms (25 ohms per wire) per Circuit Maximum Allowable Wire Capacitance 0.1 iF per Circuit For Design Reference: Wire Size Maximum Distance to EOLR #18 AWG (0.75 mm2) #16 AWG (1.00 mm2) 4,000 ft (1,219 m) #14 AWG (1.50 mm2) #12 AWG (1.50mm2) Typical N.C. Initiating Device Typical N.C. Initiating Device 0 1 INPUT 1 INPUT2 J A A A Style B (Class B) TB2 1assB)T52 BTtiy 11 ULIULC Usted Style B 471(0 EOL UL/ULC Listed UL/ULC Listed 4701 FOIL 47K0 EOL A A A Red LED Green LED o ©J ____ (Alarm/Active) (Normal) Red LED Green LED 4 3 2 1 (Alarm/Active) 4 3 2 1 (Normal) TB1 [aco llI I IBiD S f DATA IN (+) >- " DATA OUT (+) DATA IN(-) > -*- DATA From Signature Controller Y To Next Device or Previous Device 11 A-CIj GSA-CT1 HT NOTES Maximum 25 Ohm resistance per wire, Maximum #12 AWG (2.5 mm2 ) wire; Minimum #18 AWG (0.75 mm2). Refer to Signature controller installation sheet for wiring specifications. Maximum 10 Vdc @350 pA The GSA-Ul06R and the GSA-ul02R do not come with TB14. 6 All wiring is supervised and power-limited. 7 These modules will not support 2-wire smoke detectors. Warnings & Cautions This module will not operate without electrical power. As fires fre- quently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. Compatibility These modules are part of Kidde's Signature Series intelligent pro- cessing and control platform. They are compatible with VM, and VS Series control panels. Page 3 of 4 DATA SHEET K85001-0241 Not to be used for installatior, purposes. Issue 1 Technology that saves lives Contact us... Email: kidde.iire@fs.utc.com Web: k/dde, corn/engineeredsysterns 1016 Corporate Park Drive Mebane, NC 27302 Kidde is a registered mark in the United States and other countries. © 2018 Walter Kidde Portable Equipment, All rights reserved, Specifications Catalog Number GSA-CT_GSA-c J_GSA-MCT2 Description Single Input Module Dual Input Module Type Code - 48 (factory set) Four sub-types (personality codes) are available 49 (factory set) Four sub-types (personality codes) are available Address Requirements Uses One Module Address Uses Two Module Addresses Operating Current tStandby = 250pA; Activated = 400pA, jStandby = 396pA; \ Activated=68QpA Operating Voltage 15.2 to 19.95 Vdc(19 Vdc nominal) Construction High Impact Engineering Polymer Mounting North American 21/2 inch (64 mm) deep one-gang box- es and 11/2 inch (38 mm) deep 4 inch square boxes with one-gang covers and GSA-MP mounting plates UlO2R/6R/6 Motherboard Operating Environment 32°F to 158°F (0°C to 70°C) 32°F ° Storage Environment -4°F to 140°F (-20°C to 60°C); Humidity: 0 to 93% RH LED Operation On-board Green LED - Flashes when polled; On-board Red LED - Flashes when in alarm/active. Both LEDs - Glow steady when in alarm Compatibility Use with Signature Loop Controller Agency Listings UL, ULC, MEA, CSFM Ordering Information Catalog Description Ship Wt. Number lbs (kg) ,GSA-CT1 Single Input Module — UL/ULC Listed 0.4(0.15) GSA-CT1 HT Single Input Module High Teperature Operation UL/ULC Listed 0.4(015) CTöual Input Module — UIJU LC Listed 'GSA-MCT2 Dual Input Plug-in (UIO) Module - UL, ULC Listed 0.1 (0.05) Related Equipment 27193-11 Surface Mount Box - Red, 1-gang 1.0 (0.6) 27193-16 Surface Mount Box - White, 1-gang 1.0(0.6) GSA-U102R Universal Input-Output Module Board w/Riser Inputs - Two Module Positions 0.32 (0.15) GSA-U106R Universal Input-Output Module Board w/Riser Inputs - Six Module Positions 0.62 (0.28) GSA-U106 Universal Input-Output Module Board - Six Module Positions 0.56 (0.25) MFC-A Multifunction Fire Cabinet - Red, supports Signature Module Mounting Plates 7.0(3.1) GSA-MB4 Transponder Mounting Bracket (allows for mounting two 1-gang modules in a 2-gang box) 0.4 (0.15) GSA-MP1 Signature Module Mounting Plate, 1 footprint - 1.5 (0.70) GSA-MP2 Signature Module Mounting Plate, 1/2 footprint 0.5(0.23) GSA-MP2L Signature Module Mounting Plate, 1/2 extended footprint 1.02(0.46) Page 4 of 4 DATA SHEET K85001-0241 Not to be used for installation purposes, issue 1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1483:0115 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: MIRTONE*8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models GSA-CCI, GSA-CC2, GSA-CT1, GSA-CT2, GSA-CR, GSA-CRR, GSA-UM, GSA-MMI, GSA-WTM, GSA-IM, GSA-MCC2, GSA-MCT2, GSA-MCR, GSA-MCRR, GSA-MAB, GSA-MCC1, GSA-MDM remote transponders; Models GSA-U106, GSA-UI06R and GSA-UI02R motherboards. Models GSA-CCIS and GSA-MCC1S Auto-Sync Output Modules. Models MFC-A and MFC-AD enclosures. Models GSA-MP1, GSA-MP2 and GSA-MP2L mounting plates. Model GSA-CR2 Control Relay Module. *GSACRH High Power Control Relay Module. Refer to listee's data sheet for additional detailed product description and operational consideration. RATING: 15.2- 19.95 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as remote transponders for use with separately listed compatible fire alarm control units. XLF: 7300-1657:0121 *Rev. 03-29-16 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division KIDDI- otaoc Strobes. Horns, Bets, Chimes Technology that saves lives Field Configurable Horns and ,751 Strobes — S218, S5389, S2970 MEA * 7125-1501:0121 7125-1501:0146 7125-1501:0162 F CE Genesis Series ECS/MNS appliances available with clear or amber lenses. Af Ll iCi t'rittr 'r ALERT i r rT 1 fl Overview The Genesis line of fire alarm and mass notification/emergency communications (ECS/MNS) signals are among the smallest, most compact audible-visible life safety signaling devices in the world. About the size of a deck of playing cards, these devices are designed to blend with any decor. Thanks to patented breakthrough technology, Kidde Genesis strobes do not require bulky specular reflectors and lenses. Instead, an exclusive cavity design conditions light to produce a highly controlled distribution pattern. Significant development efforts employing this new technology have given rise to a new benchmark in strobe performance - FullLight technology. FullLight strobe technology produces a smooth light distribution pattern without the spikes and voids characteristic of specular re- flectors. This ensures the entire coverage area receives consistent illumination from the strobe flash. As a result, Genesis strobes with FullLight technology go well beyond the UL-1 971 and ULC-5526 light distribution requirements. Genesis strobes and horn-strobes offer selectable candela output by means of a conveniently-located switch on the side of the device. Models are also available that offer fixed 15/75 cd output. The candela output setting remains clearly visible even after final installation, yet it stays locked in place to prevent unauthorized tampering. Genesis ECS/MNS appliances offer emergency signaling with clear or amber lenses and with optional ALERT housing labels. They are ideal for applications that require differentiation between fire alarm and mass notification alerts. Standard Features Unique low-profile design -. The most compact UL-1 971 /ULC-S526 listed strobe available - Ultra-slim - protrudes less than one inch - Attractive appearance - No visible mounting screws Four field-configurable options in one device - Select 15, 30, 75, or 110 cd strobe output - Select high (default) or low dB horn output - Select temporal (default) or steady horn output - Select public mode flash rate (default) or private mode temporal flash Fixed 15/75 cd model available ECS/MNS models available Easy to install - Fits standard 1-gang electrical boxes - no trim plate needed - Optional trim plate accommodates oversized openings - Pre-assembled with captive hardware - #12 AWG terminals - ideal for long runs or existing wiring Unparalleled performance - Industry's most even light distribution - Meets tough synchronizing standards for strobes - Single microprocessor controls both horn and strobe - Independent horn control over a single pair of wires - Highly regulated in-rush current - Multiple frequency tone improves sound penetration - Field-programmable temporal strobe output option Page I of 6 DATA SHEET K85001-0573 Not to be used for installation purposes. Issue 1.1 Installation Genesis strobes are UL 1971-listed for use indoors as wall-mount- ed public-mode notification appliances for the hearing impaired. Prevailing codes require strobes to be used where ambient noise conditions exceed 105 dBA (87dBA in Canada), where occupants use hearing protection, and in areas of public accommodation as defined in the Americans with Disabilities Act (see application notes - USA). Combination horn-strobe signals must be installed in accordance with guidelines established for strobe devices. Consult with your Authority Having Jurisdiction for details. All Genesis strobes exceed UL synchronization requirements (within 10 milliseconds over a two-hour period) when used with a synchronization source. Synchronization is important in order to avoid epileptic sensitivity. WARNING: These devices will not operate without electrical power. As fires frequently cause power interruptions, further safeguards such as backup power supplies may be required. Horns Genesis horn output reaches as high as 99 dB and features a unique multiple frequency tone that results in excellent sound penetration and an unmistakable warning of danger. Horns may be configured for either coded or non-coded signal circuits. They can also be set for low dB output with a jumper cut that reduces horn output by about 5 dB. Horn-only models may be ceiling-mounted or wall-mounted. The suggested sound pressure level for each signaling zone used with is alarm signals is at least 15 dB above the average ambient sound level, or 5 dB above the maximum sound level having a duration of at least 60 seconds, whichever is greater, measured 5 feet (1.5 m) above the floor. The average ambient sound level is, A-weighted sound pressure measured over a 24-hour period. Doubling the distance from the signal to the ear will theoretically result in a 6 dB reduction of the received sound pressure level. The actual effect depends on the acoustic properties of materials in the space. A 3 dBA difference represents a barely noticeable change in volume. ECS/MNS Applications Genesis ECS/MNS strobe appliances bring the same high- performance fire alarm features and unobtrusive design to mass notification applications. Available with amber lenses and optional ALERT housing labels, they are ideal for applications that require differentiation between fire alarm and mass notification alerts. Genesis horns and strobes mount to any standard one-gang sur- face or flush electrical box. Matching optional trim plates are used to cover oversized openings and can accommodate one-gang, two-gang, four-inch square, or octagonal boxes, and European 100 mm square. All Genesis signals come pro-assembled with captive mounting screws for easy in- stallation. Two tabs at the top of the signal unlock the cover to reveal the mounting hardware. The shallow depth of Genesis devices leaves ample room behind the signal for extra wiring. Once installed with the cover in place, no mounting screws are visible. Field Configuration Genesis Horn/Strobe with optional trim plate Temporal horn and horn-strobe models are factory set to sound in a three-pulse temporal pattern. Units may be con- figured for use with coded systems by cutting a jumper on the circuit board. This results in a steady output that can be turned on and off (coded) as the system applies and removes power to the signal circuit. A Genesis Signal Master is required when horn- strobe models are configured for coded systems. Non-temporal, horn-only models Sound a steady tone. Genesis clear strobes and horn-strobes are shipped from the fac- tory ready for use as UL 1971 compliant signals for public mode operation. These signals may be configured for temporal flash by cutting a jumper on the circuit board. This battery-saving feature is intended for private mode signaling only. Genesis clear strobes and horn-strobes may be set for 15, 30, 75, or 110 candela output. The output setting is changed by simply opening the device and sliding the switch to the desired setting. The device does not have to be removed to change the output setting. The setting remains visible through a small window on the side of the device after the cover is closed. Horns and horn-strobes are factory set for high dB output. Low dB output may be selected by cutting a jumper on the circuit board. This reduces the output by about 5 dB. Wiring Field wiring terminals accommodate #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wiring. Horns, strobes, and combination horn-strobes are interconnected with a single pair of wires as shown below. G Polarity shown in alarm condition To next appliance, end-of-line or return to control equipment Note: Strobes must have continuous voltage. Page 2 of 6 DATA SHEET K85001-0573 Not to be used for installation purposes. Issue 1.1 Wall Témporal Horn-stroLiL High dB Setting UL rRMs1nTMTRMs RMS 16 Vdc f 129 167 172 } 281 337 16Vfwr { 176J230 269J 397 443 1 15 30 15/75 75 110 *EG1HDVMmulti-cd cd cd* cd cd* cd* **EG1FHDV1575 fixed 15/75 cd 16 Vdc 26 19 24 Vdc 36 27 33 Vdc 41 33 16Vfwr 51 37 24Vfwr 69 52 33 Vfwr 76 70 Typical High dB 1 Low dB Current RMS RMS _T6 Vdc 22 17 20 Vdc 24 Vdc 24 19 -- 27 22 33 Vdc 32 26 16Vfwr 34 30 20Vfwr 40 34 24 Vfwr 45 38 33Vfwr 52 47 Wall or Ceiling Mounted Horns (EG1-P) UL Designation Voltage Range J Max Current, RMS Regulated 24 16 - 33 Vdc 13 mA Vdc 24 fwr 16 - 33 Vfwr 11 mA Typical Current RMS 24 Vdc 24Vdc 10 11 31 Vdc 12 — 20Vfwr 9 24Vfwr Current values are shown in mA. Current Draw Strobes, Horn-Strobes Multi-cd WdlI Strobe&(EG14M) UL l5 cd* 30cd* S 15/75c Rating [ RMS RMS J RM 16 Vdc 1 103 141 J" 152 16Vfwr[ 125 1791 224 *EG1VM multi-cd; **EG1F V1575 fixed 15/75 Cd Typical Current 15 cd RMS 30 cd RMS 15/75 RMS 75 cd RMS llOcd RMS, f16vd1 85 1 '127 150 245 -285-- 2O Vdc 71 98 123 188 240 24 Vdc 59 82 104 152 191 33 Vdc 16Vtwr 46 119 64 1697 84 223 112 332 137 376 20Vfvvr 103 143 189 253 331 24Vtwr 94 129 169 218 262 33Vfwr 87 112 148 179 205 Typical 15 cd 30 cd 15/75 75 cd 110 cd Current TI Vdc RMS. RMS i35 RMS 160) RMS RMS — 02 246 1309 20Vdc - 88 - -- 109 137 — 193 248 24Vdc 81 94 122 161 203 33 Vdc 74 72 106 124 154 16Vfwr 144 182 247 352 393 20Vfwr 141 162 220 274 362 24VM'r -136-- 152 203 235 282 33Vfwr — 125 144 196 201 232 Wall Temporal Horn-strobes - Low dB Setting 5cd* MS 255 346 392 Horns Wall or Ceiling Mounted 110 cd* Temporal Horns (EG1-H RMS UL I High dB I Low J 15 30 15/751 75 JIlO UL cd*I cd* cd** I cd* cd* Rating 1RMS RMS I 16 Vdc f 122 160 146 1 274 1 330 16VfwrfH62 1216 231J383J29 *EG1 -HDVM multi-cd **EG1FHD\J1575 fixed 15/75 cd Typical — 15cd 30cd 15/75 75 cd 110 cd Current - RMS RMS RMS RMS RMS 16 Vdc 20 Vdc 96 79 130 104 158 133 243 189 302 241 24 Vdc 68 88 119 156 197 33 Vdc - 56 71 100 118 1 146 16Vfwr 128 180 241 344 389 20Vir 118 157 213 266 343 24Ver 113 144 195 230 279 33Vfwr 112 137 182 — 197 226 S Page 3 of 6 DATA SHEET K85001-0573 Not to be used for installation purposes. Issue 1.1 Steady Tone Horns (EG1 -P series) 16 Vdc UL464 77 dBA, mm Average 85 dBA Peak 91 dBA 16Vfwr 77 dBA, min 85 dBA 91 dBA Notes All values shown are dBA measured at 10 feet (3.01m). UL464 values measured in reverberant room. Average and Peak values are measured in anechoic chamber. I:YATi1iUj Temporal Horns, Horn-strobes (EG1-HD, EG1-HDVM series) W High UL464 Average Peak dB Temporal Steady Temporal! Temporal! Setting Steady Steady 16 Vdc 81.4 85.5 91.4 94.2 24 Vdc 84.4 88.6 94.5 97.6 33 Vdc 86.3 90.4 96.9 99.5 Low dB UL464 Average Peak Setting Temporal Steady Temporal! Steady Temporal/ Steady 16Vdc 76.0 80.1 86.3 89.2 24 Vdc 79.4 83.5 89.8 92.5 33 Vdc 82.1 86.5 92.5 95.3 Average Sound Output (dBA) (High dB setting, anechoic, 24V, measured at lOft) Light output - (effective cd) Percent of UL rating versus angle Specifications Housing Red or white textured UV stabilized, color impregnated engineered plastic. Exceeds 94V-0 UL flammability rating. Lens Optical grade polycarbonate (clear) Strobes and horn-strobes are for wall-mount installation only. Horn-only models may be ceiling- or wall-mounted. Mounting Flush mount: 21/2 inch (64 mm) deep one-gang box (indoor only) Surface mount: Model 27193 surface mount box, wiremold box, or equivalent surface-mount box With optional trim plate: One-gang, two-gang, four-inch square, octagonal, or European single-gang box Wire connections Screw terminals: single input for both horn and strobe. #18 to 412 AWG (0.75 mm2 to 2.5mm2) wire size Operating environment Indoor only: 32-120°F (0-49°C) ambient temperature. 93% relative humidity Agency listings/approvals (All UL 1971 (S218), UL 1638 (S218), UL464(S218), ULC S525, ULC S526, CSFM, CE, FCC, MEA. models comply with ADA Code of Federal Regulation Chapter 28 Part 36 Final Rule.) Dimensions (HxWxD) Signal: 4-1/2" x 2-3/4" x 13/16" (113 mm x 68 mm x 21 mm) Trimplate: 5,, (127 mm); Height-5-7/8 (149 mm); Depth - 1/2"(13 mm) EG1 -HD series temporal-tone horns: non-coded, filtered 16-33 Vdc or unfiltered 16-33 Vdc FWR (or coded when horn set to steady tone) Operating voltage EG1 -HDVM series temporal-tone horn-strobes: non-coded, filtered 16-33 Vdc or unfiltered 16-33 Vdc FWR (or coded (audible NAC only) when used with optional EG1 M Genesis Signal Master) EG1 -VM series strobes: non-coded, filtered 16 - 33 Vdc or unfiltered 16-33 Vdc FWR EG1 -P series steady-tone horns: coded or non-coded, filtered 20-31 Vdc or unfiltered 20-27 Vfwr UL 1971, UL 1638, ULC S526: selectable 15 cd, 30 cd, 75 cd, or 110 cd output Strobe output rating UL 1971: 15 cd (fixed 15/75 cd models) UL 1638, ULCS526: 75 cd (fixed 15/75 cd models) EG1 -VM strobes and EG1 -HDVM series temporal-tone horn-strobes: one flash per second synchronized with optional Strobe flash rate EG1 M Genesis Signal Master indefinitely within 10 milliseconds. Temporal setting (private mode only): synchronized to temporal output of horns on same circuit Synchronization Sources FACPs: VM and VS Series life safety systems, FX Series fire alarm control panels. Moduels: GSA-CC1 S, GSA-MCC1 5, - SIGA-CC2A, GSA-MCC2A, EG1 M-RM. Power supplies: MIRBPS6A, MIRBPS1 OA, APS6A, APS1 OA. EG1 -HD temporal-tone horns and EG1 -HDVM series temporal-tone horn-strobes: temporal rate synchronized with Horn pulse rate optional EG1 M Genesis Signal Master indefinitely within 10 milliseconds, EG1 -P steady-tone horns: continuous, steady tone only Temporal audible pattern ½ sec ON, ½ sec OFF, ½ sec ON, ½ sec OFF, ½ sec ON, 1½ sec OFF, then repeat cycle Page 4 of 6 DATA SHEET K85001-0573 Not to be used for installation purposes. Issue 1.1 Candela Output Fire appliances available with white or red housings. s Switch Switch Switch Switch li Rating Position A o?*r Position - Position Position I 1 Ei jI ç1- -.4 Amber UL 1638 110 cd 75 cd 30 cd 15 cd I Amber UL 1971* 88 cd 60 cd 24 cd 12 cd - -- - - Clear UL 1971 110 cd 75 cd 30 cd 15 cd ECS/MNS appliances available with clear or amber lenses. * Equivalent Rating - A A L v IL ALERT j ALERT r r Ordering Information 4 Model I Housing I Marking j Lens I Strobe I Horn I Ship Wt. lbs (kg) Fire Alarm Aøpliances (c/w runnino man icon screen orinted on housina E01-VM White None Clear Selectable 15, 30, 75, or 110 cd Strobe only 0.25 (0.11) EG1F-HD White FIRE Clear Horn only Selectable high/low c113 0.25 (0.11) EG1F-HDV1575 White FIRE Clear 15/75 Cd1 Temporal hi/lo dB-24V 0.25 (0.11) EG1 F-HDVMT White FIRE Clear Selectable 15, 30, 75, or 110 cd Selectable high/low dB 0.25 (0.11) EG1 F-P White FIRE Clear Steady Horn (not compatible with Genesis Signal Master) 0.25 (0.11) EG1F-V1575 White FIRE Clear 15/75 coil Strobe only 0.25 (0.11) White FIRE Clear Selectable 15, 30, 75, or 110 cd Strobe only 0.25 (0.11) EG1 -HD White None Clear Horn only Selectable high/low dB 0.25 (0.11) EG1-HDVM White None Clear Selectable 15, 30, 75, or 110 cd Selectable high/low dB 0.25 (0.11) EG1 -P White None Clear Steady Horn (not compatible with Genesis Signal Master) 0.25 (0.11) E01 RF-HD Red EG1 RF-HDV1 575 Red FIRE FIRE Clear Clear Horn only 15/75 Cd1 Selectable high/low dB Temporal hi/lo dB-24V 0.25 (0.11) 0.25 (0.11) EG1 RF-HDVM Red FIRE Clear Selectable 15, 30, 75, or 110 cd Selectable high/low dB 0.25 (0.11) EG1 RF-P Red EG1 RF-V1 575 Red FIRE jFIRE Clear Clear Steady Horn (not compatible with Genesis Signal Master) 15/75 Cd' Strobe only 0.25 (0.11) 0.25 (0.11) EG1RF-VM Red FIRE Clear Selectable 15, 30, 75, or 110 cd Strobe only 0.25 (0.11) EG1 R-HD 1 Red EG1 R-HDVM Red J None None Clear Clear Horn only Selectable 15, 30, 75, or 110 cd Selectable high/low dB Selectable high/low dB 0.25 (0.11) 0.25 (0.11) EG1 R-P Red None Clear Steady Horn (not compatible with Genesis Signal Master) 0.25 (0.11) EG1R-VM Red None Clear Selectable 15, 30, 75, or 110 Cd Strobe only 0.25 (0.11) ECS/MNS Aooliances (no runnina man icon on hnusina G1WA-VMA I White ALERT Amber Selectable A, B, C or D Strobe only 0.25 (0.11) G1WA-VMC - White ALERT Car Selectable 15,30,75,or110Cd Strobeonly 0.25(0.11) G1WN-VMA White None Amber Selectable A,B,CorD Strobeonly 0.25(0.11) G1WN-VMC White None Clear Selectable15,30,75, or110cd Strobeonly 0.25 (0.11) Trim Plates 1EG1T White None GenesisTrimPlate(for two-gang or4__ square boxes) 0_15(0_7) EG1 FIT Red None GenesisTrimPlate(for two-gang or4" square boxes) - 0.15(0.7) EG1T-FIRE White FIRE Genesis Trim Plate (for two-gang or 4" square boxes) 0.15(0.7) EG1 RT-FIRE Red FIRE GenesisTrimPlate(for two-gang or 4" squareboxes) 0.15(0.7) G1tAiT-ALERT White ALERT GenesisTrim Plate (for two-gang or 4" sq uare boxes) 0.15(0.7) Surface Boxes 27193-16 White I One-gang surface mount box 1 O4 One-gang surface mount box 1 (0.4) 'These 15/75 cd models provide fixed output and are not multi-candela devices. The 15 cd output component complies with UL-1 971, while the 75 cd output component complies with UL 1638. C Page 5 of 6 DATA SHEET K85001-0573 Not in be used for installation purposes. Issue 1.1 Technology that saves lives Contact us... Email: kidde.fire@fs.utc.com Web: kidde.com/enginee redsyst ems 1016 Corporate Park Drive Mebane, NC 27302 Kidde is a registered mark in the United States and other countries. © 2018 Water Kidde Portable Equipment. All rights reserved. S Page 6of6 DATA SHEET K85001-0573 Not to be used for installation purposes. Issue 1.1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1501:0146 Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: EDWARD SIGNAL8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: A Models EG1-VM, EGIF-VMEGIR-VM, EG1RF-VM, *EG1V1575 *EG1Rv1575 • *EG1F..v1575 and *EG1RFVI575 synchronizable strobe lights. The suffix R refers to red . rather than white housing and the suffix F refers to a silk-screened word 'FIRE" on the strobe housing. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 16-33 Vdc, Vtwr Candela: *EG1VM Series 15cd, 30cd, 75cd, 110cd selectable *EG1V1575 Series 15/75cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as strobe lights for use with separately listed compatible fire alarm control units. Units are synchronizable when used with Edwards Systems Technology Models G1 M or G1 M-RM sync module (CSFM Listing No. 7300-1591:201) which may employ Models SIGA-CCIS or SlGA-MCC1 S auto-sync output modules as an accessory (CSFM Listing 7300-1591:121). For indoor use and wall mount only. Refer to listee's Installation Instruction Manual for details. XLF: 7125-1657:0218 *Rev. 09-29-2005 jw * , This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct . RV* operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1501:0121 Page 1 of 1 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: EDWARD SIGNAL8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models EG1-HVI5, -HV30, -HV60, -HV-75; EG1-HOV15, -HOV30, -HOV60, -HOW5, -HOVIIO; EG1F-HOVI5, -HOV30, -HOV60, -HOW5, HOV110; EG1RF-HOV15, -HOV30, -HOV60, -HOW5,-HOV110, EG1-HD, EGIR-HD, EG1F-HD, EG1RF-HD, EGI-HDVM, EG1 R-HDVM, EGI F-HDVM, .EG1 RF-HDVM, EGC-HDVM, EGCF-HDVM, *EGCFR..HDVM EGC-HDVMH, EGCF-HDVMH, EG1-HDV1575, EG1 R-HDV1575, EGI F-HDV1575, and EG1 RF-HDV1575 horn/strobes with or without suffixes -R and -F. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 24-30 VDC 16-33 VdcNfwr - Models EGI -HD, EG1 R-HD, EGI F-HD, EG1 RF-HD, EG1-HDVM, EG1 R-HDVM, EG1 F-HDVM, EGI RF-HDVM, EGC-HDVM, EGCF-HDVM, *EGCFRHDVM EGI-HDV1575, EG1R-HDV1575, EG1F-HDV1575, and EGIRF-HDV1575 Candela: 15cd, 30cd, 60cd, 75cd, llocd 15-95 muti-cd - Models EGC-HDVM, EGCF-HDVM and *EGCFRHDVM 95-177 multi-cd - Models EGC-HDVMH, EGCF-HDVMH 15175cd - Models EG 1-HDV1575, EG1 R-HDV1575, EG 1 F-H DVI 575, and EGIRF-HDV1 575 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as horn/strobe lights for use with separately listed compatible fire alarm control units. For indoor use and wall mount only. Also suitable for audible signal appliances. Models EGC-HDVM and EGCF-HDVM fbr ceiling mount only. Refer to listee's Installation Instruction Manual for details. These horns can generate a distintive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition. NOTE: FORMERLY: 7125-1388:231 XLF: 7125-1657:0202 *Rev. 05-15-2007 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. CATEGORY: LISTEE: DESIGN: 7300-1483:0146 Page 1 of 1 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES MIRTONE*8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com Models MG1T,MG1RT, MG1T-FIRE, MG1RT-FIRE back boxes and trim plates for signaling appliances. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name or Edwards, Edwards Systems Technology (EST), Mirtone, Fire Alarm and Systems Technology (FAST) or Alarm Industry Products (AlP), model number and UL label. APPROVAL: Listed as signaling appliance accessories for use with separately listed signaling appliances. For indoor use only. NOTE: Formerly: 7300-1388:216 XLF: 7300-1657:0191 S *Rev. 6-9-11 ma This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other 0 Date Issued: July 01, 2019 Listing Expires August 29, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division IKie d)eihiIes Technology that saves lives Outdoor Rated Horns and Horn-Strobes r"% Genesis WG4 Series Overview Genesis WG4 Series horns and horn-strobe appliances are among the most versatile emergency appliances of their kind, Rated for indoor or outdoor use, they are suitable for a wide range of wet and harsh environments with a listed operating temperature range of as low as -40 °F to as high as 151 °F (-40 00 to 66 00). Field-configurable light and sound output settings add to their on- site flexibility, while optional FIRE markings make them ideal for fire alarm applications. These appliances are suitable for indoor and outdoor applications, and are ideal for challenging conditions such as parking garages and process areas. They are available for mounting on the ceiling or the wall, and thanks to an ingenious optional full backplane sealing gasket, can be installed to recessed (in-the-pour/block) electrical boxes. WG4 notification appliances also mount to suit- able surface boxes. Optional color-matched trim skirts provide a clean, finished appearance. All appliance wiring is accomplished room-side for easy installation. WG4 Series appliances feature an efficient and powerful piezo sounder. The multi-candela strobes are available with clear lenses in two output categories - standard and high-output. They are precision-timed to meet UL 1971 synchronization standards, and field-configurable for one of four candela intensities. Candela settings are viewable even after installation through an innovative sealed viewport display. FJL)DE Chson Strobes, Horns, Bells, Chimes Standard Features Outdoor and indoor rated Low-profile design Wall or ceiling mount Room-side wiring accepts 18 to 12 AWG (0.75 to 2.5 mm2) Wide operating temperature range Field-selectable settings Fully-compatible with Genesis synchronization protocols Standard and high-output strobe intensities Horn only and horn-strobe options 1] Page 1 of 4 DATA SHEET K85001-0628 Not to be used for installation purposes, Issue 1 Wire slot Horn Candela volume setting jumper switch (JP3) (S2) - Horn pattern jumper IJP1) Strobe pattern jumper tJP4l The suggested sound pressure level for each notification zone used with alarm notification appliances is at least 15 dB above the average ambient sound level, or 5 dB above the maximum sound level having a duration of at least 60 seconds, whichever is greater, measured 5 feet (1.5 m) above the floor. The average ambient sound level is A-weighted (fast response) sound pressure measured over a 24-hour period. Doubling the distance from the notification appliance to the ear will theoretically result in a 6 dB reduction of the received sound pressure level. The actual effect depends on the acoustic properties of materi- als in the space. A 3 dBA difference represents a barely noticeable change in volume. Strobe Application Genesis clear-lensed strobes are UL 1971-listed for use indoors as wall- or ceiling-mounted public-mode notification appliances for the hearing impaired, and UL 1638-listed for outdoor applications. Prevailing codes require strobes to be used where ambient noise conditions exceed specified levels, where occupants use hearing protection, and in areas of public accommodation. WARNING: These devices will not operate without electrical power. As fires frequently cause power interruptions, we suggest you discuss further safeguards with your local fire protection specialist. Kidde recommends that these devices always be installed in accordance with the latest recognized edition of national and local codes. Refer to the appropriate codes and standards for mounting height information. Page 2 of 4 Installation and Mounting WG4 Gasket Front cc WG4 notification appliances are rated for outdoor use and are suitable for indoor or outdoor applications on walls or ceilings. For surface-mounting in outdoor or wet applications, appliances must be mounted to a 449 or 74347U electrical box. In dry conditions, they are compatible with standard 4-in6h square by 11/2-inch deep electri- cal boxes. When using the optional WG4WTS or WG4RTS trim skirt, a 449 or 4-inch square by 2-1/8" deep box must be used. The Genesis WG4 horn and horn-strobe may be wall- or ceiling- mounted, and may be placed in one of four positions: strobe above, strobe below, and strobe to either side. The shallow depth of Gen- esis devices leaves room behind the appliance for extra wiring. Field Configuration Horn pattern: Audible output for WG4 horns and horn-strobes is factory set to to sound in a three-pulse temporal pattern. Units may be configured for use with coded systems by cutting a JP1 on the circuit board. This results in a steady output that can be turned on and off (coded) as the system applies and removes power to the notification circuit. A Genesis Signal Master is required when horn-strobe models are con- figured for coded systems. Horn output: Horns and horn-strobes are factory set for high dB output. Low dB output may be selected by cutting a jumper on the circuit board. This reduces the output by about 5 dB. Strobe pattern: Genesis WG4 horn-strobes are factory set for use as UL 1971 compliant notification appliances for public mode operation. These notification appliances may be configured for temporal flash by cutting JP4 on the circuit board. This battery-saving feature is intended for private mode signaling only. Strobe output: Genesis WG4 horn-strobes may be set for one of four out- put intensities.The output setting is changed by simply opening the device and sliding the switch to the desired setting. The device does not have to be removed to change the output setting. The setting remains visible after the cover is closed through a small window on the front of the device. DATA sr.tci K85001-0628 Not to be used for installation purposes. Issue 1 .Genesis horn output reaches as high as 97 dBA in accordance with UL 464 (104 dBA in accordance with ULC-S525) and features a unique frequency tone that results in excellent sound penetration and an unmistakable warning of danger. Horns may be configured for either coded or non-coded notification circuits. They can also be set for low dB output with a jumper cut that reduces horn output by about 5 dB. Visible appliance synchronization is required to avoid causing Sissues with people who have Photosensitive Epilepsy (PSE). Noti- fication appliance synchronization is also generally required when more than two strobe appliances are in the same field of view from any one location. All Genesis strobes meet UL synchronization requirements (within 10 milliseconds over a two-hour period) when used with a synchronization source. 40 45 50 66 €0 GO 70 - 75 Percentage of rated output S Wiring Field wiring is connected to WG4 notification appliances with terminals that accommodate #18 to #12 AWO (0.75 mm2 to 2.5 mm2) wiring. Signal In - Signal In + -I-i- designations indicate the signal polarity required to activate the device. Specifications Horns and Horn-strobes Operating voltage 24 VDC,24 VFWR nominal Dimensions (W x H x 0) 5.6 x 8.5 x 1.4 in. (142 x 216 x 36mm) Horn tone 3.2 kHz Wire size 12 to 18 AWG (0.75 to 2.50 mm2) Compatible electrical box Outdoor Model 449 or 74347U Indoor 4 in. square by 1.5 in. deep box Operating environment Temperature -40 to 151°F (-40 to 66°C) Relative humidity 0 t 95% noncondensing Compatible Synchronization Sources Horn-strobes Auto-sync Output Modules GSA-CC1 S, SIGA-CC2A, GSA- MCC1 S, GSA-MCC2A Genesis Signal Master EG1 M-RM Booster & Auxiliary Power Supplies APS6A, APS10A, MIRMIRBPS6A, MIRMIRBPS1 OA Control Panels with Genesis Synchronization built-in VS Series, VM Series, FX Series Sound Output Horns and Horn-strobes (dBA) 16V Volume Setting UL ULC- 464 S525 24V 33V UL 464 ULC- S525 UL 464 ULC- S525 Continuous High 1 89.7 94.0 94.7 99.6 97.4 102.9 Continuous Low 1 85.4 92.8 89.5 97.2 92.5 98.6 Temporal High 1 84.2 96.5 90.5 100.5 93.5 104.2 Temporal Low 181.7 90.3 85.4 94.2 88.1 97.0 dBA = Decibels, A-weighted. UL 464: Sound level output measured in a reverberant room at 10 ft. (3.05m). CAN/ULC-5525: Sound level output' measured in an anechoic room at lOft (3.05m). Light Output Angle Horizontal Plot -30 -36 -40 -45 -00 -06 .40 .45 .70 -76 .60 .66 Standard Candela Horn-strobes Strobe Switch Position Standard/rating 0 C B A UL 1971 Indoor 15 cd 29 cd 70 cd 87 cd UL 1638 Outdoor @ -35°C 6 cd 12 cd 28 cd 35 cd CAN/ULC-S526 Outdoor @ -40°C 1 cd 3 cd 8 cd 10 cd High Candela Horn-strobes Strobe Switch Position Standard/rating D C B A _UL 1971 Indoor 102cd123cd 147cd 161cd UL 1638 Outdoor @-35°C 41cd 50 cd 60 cd 65 cd CAN/ULC-S526 Outdoor © -40°C 11 cd 14 cd 17 cd 18 cd - Operating Current (UL specifies current ratings at 16 volts) ,Standard. Candela Horn-strohes in RIMS (mA), continuous Strobe Switch Position Input Voltage ________ D CB A 16VDC 127 /168 297) 351] 16 VFWR 218 239 393 422 24VDC 107 130 210 238 24 VFWR 190 222 325 356 High Candela Horn-strobes in RIMS (mA), continuous qtrnkgo cwt-'h Doo,,+,nn Input Voltage D C B A 16VDC 342 408 517 526 16 VFWR 447 502 614 679 24 VDC __246"__271__"" 327 365 24VF\NR 390 400 486 540 Horn only models (mA) 16V F4MS, continuous 24V, typical Setting High dB Low dB High dB Low d13 VDC 69.1 41.2 49.0 32.3 VFWA ,, 91.3 Signal Out - Signal Out + Page 3 of 4 DATA SHEET K85001-0628 Not to be used for installation purposes. issue 1 Ordering Information : L. Lu WG4RF-H WG4RF-HVMC WG4WF-H WG4WF-HVMC Model Housing Marking Strobe Output Ship Wt. WG4RF-HVMC Red FIRE Selectable standard candela output WG4WF-hjMC White WG4RN-HVMC Red None WG4WN-HVMC White WG4RF-HVMHC Red FIRE Selectable 1.5 lbs. WG4WF-HVMHC White WG4RN-HVMHC Red None high candela output (0.68 kg) WG4WN-HVMHC White WG4RF-H Red FIRE Horn Only WG4WF-H White WG4RN-H Red None WG4WN-H White idde Technology that saves lives Contact us... Email: kidde.fire@fs.utc.com Web: kidde.corn/engineeredsystems 1016 Corporate Park Drive Mebane. NC 27302 Kidde is a registered mark in the United States and other countries. © 2018 Walter Kidde Portable Equipment. All rights reserved, L /L W94ANH WG4RN-HVMC WG4WN-H WG4WN-HVMC Accessories WG4WTS Surface Skirt for Genesis WG4 appliance family, white. WG4RTS Surface Skirt for Genesis WG4 appliance family, red. WG4GSKT Full Body Mounting Gasket for smooth surfaces, WG4 appliance family 743470 449 Surface mount box, outdoor rated, red Surface mount box, outdoor rated, gray n Page 4 of 4 DATA SHEET K850010628 Not to be used for installation purposes. Issue 1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL LISTING SERVICE FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM Im LISTING No. 7125-1657:0311 Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, lnc.8985 Town Center Parkway, Bradenton, FL 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.micochero@carrier.com DESIGN: Models WG4RF-HVMC, WG4RN-HVMC, WG4WF-HVMC, WG4WN-HVMC, WG4RF-HVMHC, WG4RN-HVMHC, WG4WF-HVMHC, and WG4WN-HVMHC horn/strobe. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 24 VDC regulated or 16-33Vdc 24 Fwr regulated or 16-33 VMir INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as an wall/ceiling mount horn/strobe for use with separately listed compatible fire alarm control units. Units are approved for indoor or outdoor applications. Refer to manufacturer's Installation Manual for details. 05-21-12 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTIL.LO,, M.E., F.P.E. Fire Engineering Division UJjIe! K.D'Dt Ctaoc Strobes. Horns, BeHs, Chimes Technology that saves lives Low Frequency Audible, Signals Genesis G4LF Series 0 520 (9 S218 G4LF Series notification appliances provide the benefits of Gen- esis life safety signals with output suitable for applications requiring low frequency audible tones. These high-performance appliances generate a crisp 520 Hz tone in the standard 3-3 temporal pat- tern. An optional setting configures the appliance for continuous audible output - a critical feature for notification appliance circuits that are coded with a CDR-3 coder module. G4LF appliances also feature field-configurable high and low dB output settings. When connected to compatible control equipment, G4LF Series audible output remains synchronized with all Genesis audible sig- nals on the same Notification Appliance Circuit, including standard 3.2 kHz Genesis audible signals. Available G4LF models include audible-only appliances, as well as combination audible-visible signals. Combination appliances feature Genesis FuIlLightTMstrobe technology, which produces a smooth light distribution pattern without the spikes and voids that characterize bulky specular reflectors. This ensures the entire coverage area receives consistent illumination exceeding UL-1971 light distribution requirements. It also results in a slim, low profile device that blends with any decor. Candela output is field configu- rable. When connected to a compatible synchronization source, Genesis appliances synchronize (strobes to UL 1971) to within 10 millisec- onds indefinitely without the need for external modules or other equipment. See the Specifications section for a list of synchroniza- tion sources. Standard Features Unique low-profile design... - Compact UL listed audible and audible-visible appliances - Ultra-slim: protrudes an inch from the mounting surface - Attractive appearance: no visible mounting screws Choice of colors and markings... - White or red housings - With or without FIRE markings Easy to install... - Room side wiring accepts #18 - 412 AWG (0.75 to 2.5 mm2) - Fits standard 4-inch square electrical boxes or standard Gensis EG413 or EG4RB surface-mount boxes Easy to configure without removing the device... - High or low dB output - Temporal or continuous audible tone - Temporal or continuous visible output - 15, 30, 75, or 110 candela intensity High performance output... - Exclusive FullLight'5 strobe output distribution pattern - Meets tough synchronization standards for strobes and audible signals Page 1 of 4 DATA SHEET K85001-0639 Not to be used for installatior. purposes. Issue 1 Application Genesis G4LF Series appliances are UL 464-listed for low-fre- quency audible requirements. Models are also available in combi- nation with a UL 1971-listed strobe light for indoor wall-mounted public-mode notification applications. Many codes and regulations now call for low-frequency audible appliances (520 Hz) in newly constructed sleeping rooms and also require strobe lights under some of these circumstances. Consult with your Authority Having Jurisdiction for details. Combination audible-visible appliances are installed in accordance with guidelines established for visible (strobe) devices. When used with a compatible synchronization source, all Genesis xenon-based strobes - audible units, and combination appli- ances - maintain fully synchronization indefinitely. This exceeds the UL synchronization requirements of 10 milliseconds over a two-hour period. WARNING: These devices will not operate without electrical power. As fires frequently cause power interruptions, we suggest you discuss further safeguards with your local fire protection specialist. Kidde recommends that these devices always be installed in ac- cordance with the latest recognized edition of national and local codes. Refer to the appropriate codes and standards for mounting height information. For non-sleeping rooms, the suggested sound pressure level for each signaling zone used with alarm signals is at least 15 dB above the average ambient sound level, or 5 dB above the maxi- mum sound level having a duration of at least 60 seconds, which- ever is greater. This is measured 5 feet (1.5 m) above the floor. Doubling the distance from the signal to the ear will theoretically result in a 6 dB reduction of the received sound pressure level. The actual effect depends on the acoustic properties of materials in the space. A 3 dBA difference represents a barely noticeable change in volume. Visible Signal Application For sleeping rooms covered by NFPA, a strobe light is typically re- quired within 16 feet of the pillow. If the strobe light is wall-mount- ed and at or farther than 24 inches (610 mm) from the ceiling, it should be 110 cd or greater. If the strobe light is ceiling-mounted or wall-mounted closer than 24 inches (610 mm) to the ceiling, it must be 177 cd or greater. Installation Genesis G4LF Series appliances mount to a standard 4 inch (102 mm) square electrical box using the provided mounting spacer or directly to a Genesis G4 surface mount box. All Genesis appliances have two tabs at the top of the signal. Unlock the cover to reveal the mounting hardware. The shallow depth of Genesis devices leaves ample room behind the signal for extra wiring. Once installed with the cover in place, no mounting screws are visible. Flush Mounting Typical Wiring Room-side field wiring terminals accommodate #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wiring. Audible appliances, strobes, and combination audible-visual appliances are interconnected with a single pair of wires as shown. From NAc output :0, To next device or EOL From NAC output Audible Signal Application • Genesis low-frequency audible output features a code-compliant 520 Hz signal. Audible signals may be configured for either coded or non-coded signal circuits. They can also be set for low dB out- put with a jumper cut that reduces audible output by about 5 dB. Audible-only models may be ceiling-mounted or wall-mounted. For sleeping rooms, most codes and standards require 75 dBA- fast at the pillow. S Note: Polarity is shown in the active condition. Page 2 of 4 DATA SHEET K850010639 Not to be used for installati on purposes. Issue 1 40 Lt)U) Candela switch and indicator Genesis G4LF Series strobe lights may be set for 15, 30, 75, or 110 candela output. The output setting is changed by simply opening the device and sliding the switch to the desired setting. The appliance does not have to be removed to change the output setting. The setting remains visible through a small window on the side of the device after the cover is closed. Nominal Sound Level Output UL (dBA) UL 464: Sound Signal and voltage Low High level output at Temporal 16 VDC 72.4 76.0 10 ft. (3.05 m) measured in a 24 VDC 72.3 75.7 reverberant room. 33 VDC 73.3 75.4 Continuous 16 VDC 75.7 79.8 24 VDC 76.1 78.6 33 VDC 75.4 78.8 JP3 Audible dB Output: JP3 cut for low, JP2 Audible I pattern: cut for steady. JP1 Strobe pattern: cut JP1 I for temporal (private mode only(. Field Configuration Genesis G4LF Series audible appliances are factory set to oper- ate in a Temporal 3 (three-pulse) pattern. Units may be configured for use with coded systems by cutting jumper JP2 on the circuit board. This results in a steady output that can be turned on and off (coded) as the system applies and removes power to the signal circuit. A Genesis Signal Master is required to maintain G4LF strobe light synchronization when connected to a coded system. Audible signals and combination audible-visible appliances are factory set for high dB output. Low dB output may be selected by cutting jumper JP3 on the circuit board. This reduces the output by about 5 dB. Genesis G4LF Series strobe lights are shipped from the fac- tory ready for use as UL 1971 compliant signals for public mode operation. These signals may be configured for temporal flash by cutting jumper JP1 on the circuit board. This battery-saving feature may be used for private mode signaling only. Light Output Per cent of UL rating versus angle ---'5505 Candela HSpac, -% 05 Candela V Spec, 41 75 :o:5 80 Minium UL required Candela light output Current Draw Audible-Visible Appliances Operating horn-strobe current in RMS (mA) with audible set to standard (high) output Strobe 15 30 F-75 110 output (Cd) Temporal 16VDC) 219 266) p381 1437 16 VFWR 308 — 362 510 579 24 VDC 151 176 243 278 24 VFWR 228 258 349 - 395 33 VDC 33 VFWR 112 186 132 1 208 177 1 267 199 1 291 Continuous 16 VDC 221 258 371 433 16 VFWR 305 358 514 576 24 VDC 147 171 239 274 24 VFWR 211 247 335 377 33 VDC 33VFWR 110 178 179 199 175 257 196 282 VDC = Volts direct current, regulated and filtered VFWR = Volts full wave rectified Operating Current RMS (mA) Audible appliance only Signal and voltage Low High Temporal 16 VDC 86 166 24 VDC 43 112 33 VDC 36 87 16 VFWR 97 215 24 VFWR 78 — 159 33 VFWR 76 140 Continuous 16VDC 36 160 24 VDC 33 VDC 45 36 109 86 16 VFWR 92 212 24 VFWR 80 168 33 VFWR 77 L 141 VDC = Volts direct current, regulated and filtered VFWR = Volts full wave rectified Page 3 of 4 DATA SHEET K85001-0639 Not to be used for Installation purposes. Issue 1 Technology that saves lives Contact us... Email: kidde.fire@fs.utc.com Web: k/dde. com/eng/neeredsysterns 1016 Corporate Park Drive Mebane, NC 27302 Kidde is a registered mark in the United States and other countries. © 2018 Walter Kidde Portable Equipment. All rights reserved. Page 4 of 4 Specifications Genesis G4LF Audible and Visible Signals Operating voltage 24 VDC or 24 VFWR [1] Housing Red or white textured UV stabilized, color impregnated engineered plastic. Dimensions Height: 6.5" (165 mm). Width: 5" (127 mm). Depth to wall: 1(25 mm). Mounting Flush: North-American 4" square box, 2 1/8(54 mm) deep. Requires (indoor wall mount supplied spacer. only) Surface: model EG4B (white) or EG4RB (red) surface mount box. Synchrorazation FACPs: VM and VS Series life safety systems, FX Series fire alarm control Sources panels. Moduels: GSA-CC1S, GSA-MCC1S, SIGA-CC2A, GSA-MCC2A, EG1M-RM. Power supplies: MIRBPS6A, MIRBPS10A, APS6A, APS10A. Wire Size 12 to 18 AWG (0.75 to 2.50 mm2). Operating 32-120° F (0.490 C) ambient temperature; 0-93% relative humidity, environment noncondensing. Audible Signal Audible pulse rate Temporal rate with compatible synchronization source: indefinitely within 10 milliseconds. Temporal audible ½ sec ON, ½ sec OFF, ½ sec ON, ½ sec OFF, ½ sec ON, 11/2 sec OFF, pattern then repeat cycle. Visible stroDe Output Hating UL 1 Y11: selectable 15 cd, 30 cd, 75 cd, or 110 cd output Strobe Operating 16 - 33 Vdc Regulated, 16-33 V Full wave rectified (UL Voltage Voltage Designations "Regulated 24" and "24 fwr") Strobe Flash Rate One flash per second. One flash per second (fps) within 10 milliseconds over a 2 hour time Strobe Flash period on a common circuit. Synchronization source required to comply Synchronization with UL 1971 synchronization standard. Temporal setting (private mode only): synchronized to temporal output on the same circuit. Strobe Lens Material Polycarbonate [1] This device was tested to the Regulated 24 DC/RNR operating voltage limits of 16 V and 33 V Do not apply 80% and 110% of these values for system operation. Ordering Information Model Housing Marking I Audible I Signal I Visible Signal I Ship Wt. lbs (kg) Fire Alarm Appliances (520 Hz screen printed on housing) G4LFWN-HVM White None Low Frequency (520 Hz) with selectable High/Low dB output. Selectable 15, 30, 75 or 110 cd. Audible Only. 1.5 lbs. (0.68 kg) M1 ' White FIRE G4LFRN-HVM Red None G4LFRF-HVM Red FIRE G4LFWN-H White None G4LFWF-H White FIRE G4LFRN-H Red None G4LFRF-H Red I FIRE Accessories GSA-CC1 S 6SA-MCC1S Intelligent Synchronization Output Module (2-gang) - Synchronization Output Module (Plug-in UIO( 0.5 (0.23) 0.18 (0.08) SIGA-CC2A Dual Input Signal Module with Class A Operation (2-gang) 0.5 (0.23) GSA-MCC2A Dual Input Signal Module with Class A Operation (Plug-in UIO) 0.18 (0.08) EG4B Surface mount box, white 0.7 (0.32) EG4RB Surface mount box, red 0.7 (0.32) DATA SHEET K85001-0639 Not to be used for installation purposes. Issue 1 S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM NO S LISTING SERVICE LISTING No. 7135-1657:0319 Page 1 of 1 CATEGORY: 7135--AUDIBLE DEVICES LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover©fs.utc.com DESIGN: Models G4LFWN-HVM, .G4LFWF-HVMG4LFRN-HVM and G4LFRF-HVM low frequency electronic horn strobe for sleeping areas. The suffix R refers to red and W refers to white housing; the suffix F refers to the word FIRE silkscreened on housing; N indicates no marking on housing. Intended for indoor use and mounted on a wall. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 16-33 VdcNfwr Candela: 15, 30, 75 or 110 cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as a strobe, horn/strobe for the hearing impaired when used with separately listed electrically compatible fire alarm control units. Units are synchronizable when used in . conjunction with listed Models G1 or GIM-RM (CSFM listing No. 7300-1657:0201) sync module or Models SIGA-CC1S or SIGA-MCC1S Auto-Sync output modules (CSFM listing No. 7300-1657:0121). For wall mounted, indoor use only. These units can generate a low frequency alarm signal for sleeping areas in accordance with NFPA 72. Refer to listee's Installation Instructions Manual for details. 03-04-2014 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7135-1657:0320 Page 1 of 1 CATEGORY: 7135 -- AUDIBLE DEVICES LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, lnc.8985 Town Center Parkway, Bradenton, 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models G4LFWN-H,4LF\NF-H,-H and G4LFRF-H low frequency electronic horn for sleeping areas. The suffix R refers to red and W refers to white housing; the suffix F refers to the word FIRE silkscreened on housing; N indicates no marking on housing. Intended for indoor use and mounted on a wall. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 16-33 Vdc/Vfwr INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as a horn when used with separately listed electrically compatible fire alarm control units. For indoor use only on ceiling or wall. These units can generate a low frequency alarm signal for sleeping areas in accordance with NFPA 72. Refer to listee's Installation Instructions Manual for details. 03-11-14 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING BUILDING MATERIALS LISTING PROGRAM . LISTING SERVICE LISTING No. 7135-1657:0319 Page 1 of 1 CATEGORY: 7135--AUDIBLE DEVICES LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, lnc.8985 Town Center Parkway, Bradenton, FL 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.micochero@carrier.com DESIGN: Models G4LFWN-HVM, G4LFWF-HVM, G4LFRN-HVM and G4LFRF-HVM low frequency electronic horn strobe for sleeping areas. The suffix R refers to red and W refers to white housing; the suffix F refers to the word FIRE silkscreened on housing; N indicates no marking on housing. Intended for indoor use and mounted on a wall. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 16-33 VdcNfwr Candela: 15, 30, 75 or 110 cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as a strobe, horn/strobe for the hearing impaired when used with separately listed electrically compatible fire alarm control units. Units are synchronizable when used in • conjunction with listed Models G1M or G1M-RM (CSFM listing No. 7300-1657:0201) sync module or Models SIGA-CC1S or SIGA-MCC1S Auto-Sync output modules (CSFM listing No. 7300-1657:0121). For wall mounted, indoor use only. These units can generate a low frequency alarm signal for sleeping areas in accordance with NFPA 72. Refer to listee's Installation Instructions Manual for details. 03-04-2014 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM S LISTING SERVICE LISTING No. 7135-1657:0320 Page 1 of 1 CATEGORY: 7135--AUDIBLE DEVICES LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, lnc.8985 Town Center Parkway, Bradenton, FL 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.micochero@carrier.com DESIGN: Models G4LFWN-H, G4LFWF-H G4LFRN-H and G4LFRF-H low frequency electronic horn for sleeping areas. The suffix R refers to red and W refers to white housing; the suffix F refers to the word FIRE silkscreened on housing; N indicates no marking on housing. Intended for indoor use and mounted on a wall. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 16-33 VdcNfwr INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as a horn when used with separately listed electrically compatible fire alarm control units. For indoor use only on ceiling or wall. These units can generate a low frequency alarm signal for sleeping areas in accordance with NFPA 72. Refer to listee's Installation Instructions Manual for details. S 03-11-l4gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verity correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other 0 Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division II1 A 7136-1657: lvi M 0150 S218, S2202 Technology that saves lives MaIrM1111"F1 i iiif1I KD E (tac: P. Stobes, Horns, Bells, Chimes Overview Kidde Fire Alarm Bells are specially designed for fire alarm applica- tions. The gongs are made of selected alloy steel to give the loud, resonant tones necessary in fire alarm systems. Two gong sizes are available to overcome different ambient noise level. The Fire Alarm Bells are of the underdome type with heavy duty mechanisms. Each bell is supplied with a mounting plate that fits any standard single-gang opening (see Installation Data). For weather-proof application Kidde offers an optional surface weath- erproof back box. Refer to the Specification chart for applicability and cata-log number of the weatherproof back box for the respec- tive bell. Finish - Standard gong and housing furnished gray with red label. Optional red finish available. Add Suffix "R" to Catalog Number. FM - 438 and 439 Series Bells shown below are FM approved. Standard Featu'es Viorating and single stroke 6 inch (150mm), E inch (200mm), 10 inch (250mm) sizes Red or gray finish Rugged compact mEchanism Hoavy cut'i cast housing Low power drain Wide vcltage selection Indoor or weatherprcof Page 1 of 2 DATA SHEET K85001-0333 No to DO L sac for orotaHaion purposes. Issue 1 installation ggrgp M — Cat. Nos. 438D and 439D6" and lo"Bells iddle ___________________ / N / \ 10' 0)5. GONO ' 10' 015. GONG - Technology that saves lives / ' (BASE) / I. I OUTLET (170rm,,( )•-• (1170, Contact us... k000 6'DIA.GONG 8'D)5.GOMG 11116' 07.5.m) Email: kidde.fire@fsutc.com 7' (150001) f ( F—Ti 3' CAT.N0449 WEATAER. Web: k/dde.corn/engineeredsystems ( (( 0 )) ) / / frL. ICL OF BASE PROOF BOX. - - FUNTED GRAY) II (7nveJ 1; I 2.2902' x1G6, Mebane, NC 27302 N - 1016 Corporate Park Drive Kidde is a registered mark in the United States MOUNTING PLATE (FURNISHED) ,,,. and other Countries MOUNTS DIRECTLY ON SURFACE OR ANY SINGLE GANG OPENING, 5.0' 3-1(2', 4' OCTAGON, 4' SOL BOX OR CAT © 2018 Wafter Kidde Portable Equipment. NO. 449 WEATHERPROOF WALL BOX. (I43on) All rights reserved, Cat. Nos. 325D and 10" (254mm) Belts 4' ((ORAll)1 FIRE BELL L.— .g,r WARNING: These devices will not op- '—.- C w- erate without electrical power. As tires frequently cause powerinterruptions, we suggest you discuss further safeguards Dlx. GONG - with your local fire protection specialist. (15001,11) I I 7. Kidderecommends that these Fire Ajarm / ) ) / ) )178nn) Bells always be installed in accordance I I with the latest recognized editions of - I / 1O'OLAGONG ., ) I — - (250mm) national and local codes. Specifications & Ordering Information Weatherproof Cat. No. DB @ Description Volts Amps loft Box 323D-10AW-R 79 10" (250mm) 20-24 Vdc 0.33 N/A Single Stroke, Diode 438D-6N5-R 76 6(150mm) 120 Vac 0.034 449 Vibrating, Diode "438D-10N57RD 88 10" (250mm) 120 Vac 0.034 449 Vibrating, Diode 439D-6AW-R 83 6" (150mm) 20-24 Vdc 0.085 449 Vibrating, Diode 439D-10AW-R 86 10" (250mm) 20-24 Vdc 0.085 449 Vibrating, Diode 438D-8N5-R 86 8" (200mm) 120 Vac 0.034 449 Vibrating, Diode 439D-8AW-R 84 8(200mm) 20-24 Vdc 0.085 449 Vibrating, Diode 439D-6AWC-R 83 6" (150mm) 20-24 Vdc 0.085 449 Vibrating, Diode, ULC listed 439D-10AWC-R 86 10" (250mm) 20-24 Vdc 0.085 449 Vibrating, Diode, Mounting Accessories 449 Weatherpoof surface mount box, grey. C/w gasket. 1(0 Page 2of 2 DATA SHEET K85001-0333 Not to be used for instatlation purposes. Issue 1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL S FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7136-1657:0150 Page 1 of 1 CATEGORY: 7136--AUDIBLE DEVICES FOR HAZARDOUS LOCATIONS LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, lnc.8985 Town Center Parkway, Bradenton, FL 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.micochero@carrier.com DESIGN: Models 325, 340, 3401, 343, 438, 439, 439D series and explosion-proof Models CS2315, CS2316 and 3400EX, 435DEX, 438DEX, 4390EX series vibrating bells. Models 325, 340, 3401, 343, 438, 439, 4390 may be used outdoors when used with a weatherproof box. Refer to listee's data sheet for detailed model description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, hazardous location classification (if applicable) and UL label. APPROVAL: Listed as audible devices for use with separately listed compatible control units. Explosion-proof models intended for use in Class I, Groups B,C,D; Class II, Groups E,F,G hazardous locations. If this appliance is required to produce a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition, the appliance must be used with a fire alarm control unit that can generate the temporal pattern signal. Refer to manufacturer's Installation Manual for details. NOTE: Formerly 7136-1591:150, 7135:1591:150, 7135-1388:110, 7135-0073:032 7-29-10 ma This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division - SYSTEM RECORD OF COMPLETION E?6 7070 of This form is to be completed by the system installation contractor at the time of system acceptance and approval. It shall be permitted to modify this form as needed to provide a more complete and/or clear record. Insert N/A in all unused lines. Attach additional sheets, data, or calculations as necessary to provide a complete record. Form Completion Date: 5-6-20 Supplemental Pages Attached: PROPERTY INFORMATION Name of property: Oakmont of Carlsbad Marketing Office Address: 2580 Faraday Ave. Carlsbad, Ca. 92010 Description of property: Senior Living Marketing Office Name of property representative: Oakmont Senior Living Address: 9240 Old Redwood Highway, STE 200 Windsor, Ca. 95492 Phone: 707-535-3200 Fax: E-mail: INSTALLATION, SERVICE, TESTING, AND MONITORING INFORMATION Installation contractor: Cal Building Systems Address: 3900 Prospect Ave. STE. B Yorba Linda ave. 92886 Phone: 714-993-9650 Fax: E-mail: Service organization: Same as above Address: Phone: Fax: E-mail: Testing organization: Same as above Address: Phone: Fax: E-mail: Effective date for test and inspection contract: Monitoring organization: Crime Alert Address: 690 Lenfest Rd. San Jose Ca 95133 Phone: 1-800-367-1091 Fax: E-mail: Account number: 61-4855 Phone line 1: Phone line 2: Means of transmission: Cellular Entity to which alarms are retransmitted: Phone: DOCUMENTATION On-site location of the required record documents and site-specific software: Main Lobby at FACP DESCRIPTION OF SYSTEM OR SERVICE This is a: M New system 0 Modification to existing system Permit number: FPC2020-0126 NFPA 72 edition: 2016 4.1 Control Unit Manufacturer: Kidde Model number: VS1 4.2 Software and Firmware Firmware revision number: 4. 4.3 Alarm Verification Z This system does not incorporate alarm verification. Number of devices subject to alarm verification: Alarm verification set for seconds Copyright © 2012 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. (p. 1 of 3) SYSTEM RECORD OF COMPLETION (continued) 5. SYSTEM POWER 5.1 Control Unit 5.1.1 Primary Power Input voltage of control panel: 120 VAC Overcurrent protection: Type: Breaker Branch circuit disconnecting means location: 5.1.2 Secondary Power Type of secondary power: Sealed Lead Acid Batteries Location, if remote from the plant: Calculated capacity of secondary power to drive the system: In standby mode (hours): 24 Control panel amps: Amps: 15 Number: In alarm mode (minutes): 5 5.2 Control Unit 0 This system does not have power extender panels Power extender panels are listed on supplementary sheet A & CIRCUITS AND PATHWAYS Pathway Type Dual Media Pathway Separate Pathway Class Survivability Level Signaling Line B Device Power Initiating Device Notification Appliance B Other (specify): REMOTE ANNUNCIATORS Type Location LCD FRONT LOBBY INITIATING DEVICES Type Quantity Addressable or Conventional Alarm or Supervisory Sensing Technology Manual Pull Stations 1 Addressable Alarm Smoke Detectors 18 Addressable 8 Alarm 10 Supervisory Duct Smoke Detectors NA Heat Detectors NA Gas Detectors NA Waterfiow Switches I Addressable Alarm Tamper Switches 1 Addressable Alarm Copyright @2012 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. (p. 2of3) SYSTEM RECORD OF COMPLETION (continued) 9 NOTIFICATION APPLIANCES Type Quantity Description Audible 7 Horn Visible 4 Strobe Combination Audible and Visible 5 Horn Strobe 10. SYSTEM CONTROL FUNCTIONS Type Quantity Hold-Open Door Releasing Devices NA HVAC Shutdown NA Fire/Smoke Dampers NA Door Unlocking NA Elevator Recall NA Elevator Shunt Trip NA INTERCONNECTED SYSTEMS Z This system does not have interconnectedsystems. 0 Interconnected systems are listed on supplementary sheet CERTIFICATION AND APPROVALS 12.1 System Installation Contractor This system s spec ied rem has been installed according to all NFPA standards cited herein. Signed:, Zs Printed name: Gilbert Galaz Organization: Cal Building stems Title: Technician 12.2 System Operational Test This system as specified herein has tested according to all NFPA standards cited herein. Signed: Printed name: Organization: Title: Phone: 12.3 Acceptance Test Date and time of acceptance test: Installing contractor representative: Testing contractor representative: Property representative: AHJ representative: Copyright 0 2012 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. (p. 3of3) Date: Phone: Date: PRE TEST 5-5-2021 SUPV ACT 1 09:01:44 05/05/2021 L:1 D:018 UNIT 101 SMOKE DET LIVING ROOM SUPV ACT I 09:02:19 05/05/2021 1:1 D:019 UNIT 101 SMOKE DET BEDROOM SUPV ACT I 09:03:15 05/05/2021 L:1 D:017 UNIT 102 SMOKE DET BEDROOM SUPV ACT 1 09:04:22 05/05/2021 L:1 D:016 UNIT 102 SMOKE DET LIVING ROOM SUPV ACT 1 09:04:52 05/05/2021 L:1 D:015 UNIT 102 SMOKE DET DEN SUPV ACT I 09:05:47 05/05/2021 L:1 D:014 UNIT 102 SMOKE DET BEDROOM PULL ACT I 09:06:27 05/05/2021 L:1 D:013 LOBBY PULL STATION SMK ACT I 09:06:58 05/05/2021 L:1 D:005 LOBBY SMOKE DETECTOR SMK ACT I 09:07:56 05/05/2021 L:1 D:006 FRONT OFFICE SMOKE DETECTOR SMK ACT I 09:08:46 05/05/2021 L:1 D:007 MIDDLE OFFICE SMOKE DETECTOR SMK ACT I 09:09:23 05/05/2021 L:1 0:008 RESTROOM SMOKE DETECTOR SMK ACT I 09:10:48 05/05/2021 L:1 D:010 COPY ROOM SMOKE DETECTOR SMK ACT I 09:11:38 05/05/2021 L:1 D:011 CONFERENCE ROOM SMOKE DETECTOR SMK ACT 1 09:12:26 05/05/2021 L:1 D:012 BACK OFFICE SMOKE DETECTOR SUPV ACT 1 09:13:47 05/05/2021 L:1 D:004 UNIT 103 SMOKE DEl BEDROOM SUPV ACT I 09:14:19 05/05/2021 L:1 D:003 UNIT 103 SMOKE DEl BEDROOM SUPV ACT I 09:14:52 05/05/2021 L:1 D:002 UNIT 103 SMOKE DET LIVING ROOM SUPV ACT I 09:15:35 05/05/2021 L:1 D:001 UNIT 104 SMOKE DEl SUPV ACT I 09:16:30 05/05/2021 L:1 0:021 MARKETING PIV SUPV RST I 09:16:38 05/05/2021 L:1 D:021 MARKETING PIV ALRM ACT I 09:20:53 05/05/2021 L:1 D:020 MARKETING WATERFLOW