Loading...
HomeMy WebLinkAbout3339 TYLER ST; ; FPR2019-0218; Permit6;1 of PERU[T REPORT Carlsbad mff(~) P@MXDR Print Date: 10/05/2022 Permit No: FPR2019-0218 Job Address: 3339 TYLER ST, CARLSBAD, CA 92008 Status: Closed - Finaled Permit Type: FIRE-Construction Residential Work Class: Underground Fire Parcel #: 2040701000 Track #: Applied: 11/06/2019 Valuation: $0.00 Lot #: Issued: 12/05/2019 Occupancy Group: Project #: Finaled Close Out: 01/06/2020 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check #: INSPECTOR: Maldonado, Adalmira Plan Check #: Project Title: Description: TYLER ST RESIDENCES - UNDERGROUND & BACKFLOW FEE AMOUNT FIRE Underground Piping with up to 4 Hyds/Risers $1,512.00 Total Fees: $1,512.00 Total Payments To Date: $1,512.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov ZURN Model 475DA/475DAV WILKINS Reduced Pressure Detector Assembly Application Designed for installation on water lines in fire protection systems to protect against both backsiphonage and backpressure of contaminated water into the potable water supply. The Model 475DA/475DAV shall provide protection where a potential health hazard exists. Incorporates metered by-pass to detect leaks and unauthorized water use. Standards Compliance ASSE® Listed 1047 (4" thru 8") AWWA Compliant C550 UL® Classified (4" thru 10") C-UL® Classified (4" thru 10") FM® Approved (4" thru 8") NYC MEA 170-02-M VOL 2(4"thru 8") Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California (4" thru 8") NSF® Listed-Standard 61, Annex G* *(025% MAX. WEIGHTED AVERAGE LEAD CONTENT) Materials Main valve body Ductile Iron ASTM A 536 Grade 4 Access covers Ductile Iron ASTM A 536 Grade 4 Coatings FDA Approved fusion epoxy finish Fasteners Stainless Steel, 300 Series Elastomers EPDM (FDA approved) Buna Nitrile (FDA approved) Polymers NORYLTM, NSF Listed Springs Stainless steel, 300 series Features Sizes: 4°, 6°, 8°, 10' Maximum working water pressure 175 PSI Maximum working water temperature 140°F Hydrostatic test pressure 350 PSI End connections (Grooved for steel pipe) A\NWA C606 (Flanged) ANSI 1316.1 Class 125 Relief Valve discharge port: 21/2-6" - 2.75 sq. in. 8" - 10" - 3.69 sq. in. Dimensions & Weights (do not include pkg.) WEIGHT________ MODELS 475DA LESS WITH WITH WITH BFLY WITH BFLY & SHUTOFF °ATE VALVES VALVES 475DAV VALVES GATES GATES (GXF) (GXG) SIZE (GXF) (GXG) lbs. I kg lbs. I kg lbs. kg lbs. kg 4" 113 51 303 137 279 127 18 161 73 6" 187 85 487 221 465 211 lbsglkg 29 261 421 191 897 407 118 8" 843 382 61 565 256 10" 439 199 1113 505 1055 479 71 655 297 r!1NSF P,I MODEL 475DAV MODEL 475DA Options (Suffixes can be combined) El - with OS & Y gate valves (standard) El L - less shut-off valves (grooved body connections) LI LM - less water meter LI - with remote reading meter LI - with gpm meter (standard) LI - with cu ft/min meter LI V - vertical flow up configuration LI G - with groove end gate valves jI FG - with flanged inlet gate connection and grooved outlet gate connection LI MS - with integral relief valve monitor switch LI BG - with grooved end butterfly valves with integral supervisory switches LI BF - with flanged end butterfly valves with integral supervisory switches LI P1 - with post indicator gate valve Accessories Air gap (see spec sheet BF-AG) LI Repair kit (rubber only) LI Thermal expansion tank (Model XT) LI Valve setter (Model FLS or LI MJS or MJFS) LI Gate valve tamper switch (OSY-40) LI 01-SET Quick Test Fitting Set 100.9 138 ' - (150mm) 103 -J 69 w 34 (1) w it 0 0 1600 189.3 138 an rfl)* 103 69 LU 34 ILI 0 ° 3000 Flow Characteristics 0.0 O 20 0. 15 U) U) 0 -J 10 uJ U) 5 1 I w o.0 I 'I'!' 800 1200 FLOW tIRATES il MODEL 475DA & 475DAV 8" & 10" (STANDARD & METRIC) I,FLOW RATES (1/s) V1.I' Iii FLOW RATES (GPM) MODEL 475DA & 475DAV 4" & 6" (STANDARD & METRIC) FLOW RATES (us) 25.2 50.5 75.7 1000 2000 ct Rated Flow (established by approval agencies) (0L curve) Typical Installation Local codes shall govern installation requirements. To be installed in accordance with the manufacturers' instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. Capacitythru Schedule 40 Pipe (GPM) Pipe size 5 ft/sec 7.5 ft/sec 10 ft/sec 15 ft/sec 2 1/2 75 112 149 224 3' 115 173 230 346 4" 198 298 397 595 6" 450 675 900 1351 8" 780 1169 1559 2339 10" 1229 1 1843 2458 3687 MODEL SIZE in. mm DIMENSIONS (approximate) Al SETTER END TO ENDFLS in. I mm Al SETTER END TOEND MJS in. I mm 4 1001 31 5116 795 295/16 745 6 150 34 3/4 884 32 3/4 832 8 200 47 1194 445/8 1133 10 250 51 1295 47 1194 WIL VERTICAL INSTALLATION OUTDOOR INSTALLATION Specifications The Reduced Pressure Detector Assembly shall be ASSE® Listed 1047, and supplied with full port OS & V gate valves. The main body and access covers shall be epoxy coated ductile iron (ASTM A 536 Grade 4), the seat ring and check valve shall be NORYLTM, the stem shall be stainless steel (ASTM A 276) and the seat disc elastomers shall be EPDM. The first and second checks shall be accessible for maintenance without removing the relief valve or the entire device from the line. If installed indoors, the installation shall be supplied with an air gap adapter. The Reduced Pressure Detector Assembly shall be a ZURN WILKINS Model 475DA or 475DAV. Zurn Industries, LLC I Wilkins 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 In Canada I Zurn Industries Limited 3544 Nashua Drive, Mississauga, Ontario L4V 1L2 Ph. 905-405-8272, Fax 905-405-1292 wwwzurncom Page 2 of 2 I. MEGALUGO Series 1100 Mechanical Joint Restraint for Ductile Iron Pipe 3 1103 6.1 30 350 [ 4 1104 7.7 30 350 j 6 1106 11.9 30 350 L 8 1108 14.8 30 350 10 1110 23.9 30 350 1 12 1112 31.2 30 350 14 1114 48.5 2 0 350 16 1116 56.4 2 0 350 j 18 1118 63.1 11/2 ° 250 20 1120 723 11/2° 250 J 24 1124 133.1 11/2 0 250 [ 30 1130 194.6 10 250 7 36 1136 234.0 10 250 L 42 1142 536.0 10 250 1 48 1148 653.0 10 250 Features and Applications: Sizes 3 inch through 54 inch Constructed of ASTM A536 Ductile Iron Torque Limiting Twist-Off Nuts MEGA-BOND® Restraint Coating System For more information on MEGA-BOND, refer to www.ebaa.com The Mechanical Joint Follower Gland is incorporated into the restraint Heavy Duty thick wall design Support Products Available: Split repair style available 3 inch through 48 inch. EBAA Series IIOOSD Solid restraint harness available for push-on pipe bells. EBAA Series 1700 Split restraint harness available for existing push-on bells. EBAA Series IIOOHD All MEGALUG and related restraint products can be furnished as packaged accessories complete with appropriate restraint, gasket, lubrication, and bolt- ing hardware 54 1154 700.2 0.5 0 200 • For use on water or wastewater pipe- lines subject to hydrostatic pressure and tested in accordance with either AWWA C600 or ASTM D2774 Made In U.S. Patent Nos. 4092036, 4627774, 4779900, 4896903, 5544922 The USA 0218-J Copyright © 2018. EBAA Iron, Inc. All Rights Reserved. MEGALUG: THE PRODUCT OF PREFERENCE SINCE 1984 Since 1984, engineers and contractors designing and installing water and wastewater pipelines and systems have come to rely on the EBAA Series 1100 MEGALUG Mechanical Joint Restraint as the "Product of Preference" for effectively and economically restraining ductile iron pipe connections above or below ground. MEGALUG Mechanical Joint Restraints replace external re- straints such as cumbersome concrete thrust blocks and corrod- ible metal tie rods creating a quicker, safer and more economical installation. Major testing laboratories agree as the 3" througi 24" sizes are Underwriters Laboratories (UL) listed, and the 3" through 12" sizes are Factory Mutual (FM) approved. For use on all classes of ductile iron pipe (PC350 through PC150 and CL56 through CL50), for practically any application including valves, hydrants and pipe, the MEGALUG Mechanical Joint Restraint effectively and safely performs without damage to the pipe or cement linings. THE MEGALUG GRIPPING WEDGE.. PERFORMANCE PROVEN The wedge style MEGALUG design reacts to the amount of force acting on the joint. When each wedge is set, the wedge teeth penetrate the pipe's outer surface, and the wedge does not move on the pipe. There is very little change in this interface until the wedge movement begins inside the pocket of the main casting. Once the wedge starts moving, the formation of the buttress begins. This "dam" of material (the wedge impression) is cold formed as the wedging action continues. If the force of pressure acting on the joint is released, the wedge moves back to near its original position. This engages the reserve-controlled move- ment or 'RCM". The wedge is then ready for another round. After the wedge has moved to the back Ui / Max pressure 0 Movement I LI.. causes I wedges to jseiJ-:exw::e: Rated pressure W Wedge movement cc: ( begins o I____ W Normal operating pressure (I) Ui Of CL ~RCM~l MOVEMENT of the pocket at the maximum pressure or load, the wedge buttress are in shear. The maximum movement is about 0.3 inch through the thirty-six inch size and 0.4 inch for forty-two and forty-eight inch. The RCM is available even with severe cyclic loads. This has been tested to very high-pressure differentials and the wedge impressions look the same as if a single test had been performed. Typically, the depth of pipe wall pen- etration, or wedge impression at around 25,000 pounds of force per wedge (200 PSI on a six inch and 150 PSI on a twelve inch) is 0.03". Finally, at roughly twice that force the penetration is around 0.05" At these high pressures, there is no affect on the design thickness of ductile iron pipe made according to AWWA C150. The lack of damage to the cement lining clearly indicates that the thrust load is primarily longitudinal. This ability to move in the pocket allows for angular flexibility as well as longitudi- nal flexibility. THE ORIGINAL PATENTED ___ allowed by the GRIPPING WEDGES ________ echanical joint uring installation, it can also deflect Since 1964 EBAA Iron has responded after assembly: aggressively to the needs of the Sizes of 12" and below water industry for better solutions are capable of up to 3 to joint restraint problems - thus the degrees of deflection after development of the family of self I installation (depending on the actuating MEGALUG wedge action preset deflection.) restraints. The 14" and 16" sizes are TOOLS capable of 2 degrees deflection. The 18" through 24" sizes are MEGALUGS install using an ordinary capable of 1.5 degrees deflection. wrench (box, ratchet, or air-driven), The 30" through 48" sizes are capable of because the torque-limiting, twist- 1 degree deflection. off nuts automatically shear during The 54" size has a 0.5 degree deflection. tightening when the proper torque is reached. The same 11/4 wrench STEEL PIPE used to tighten the T-bolts on the The 1100 Series MEGALUG can be used to restrain 4" through 24" sizes can be used 3" -8" SCH 40 or 80 steel pipe when joining to to tighten and shear the twist off mechanical appurtenances. It can also be used on nuts in all sizes. If removal becomes steel pipe in all sizes if the pipe's outside diameter is necessary, a 5/8 hex head remains the same as the ductile iron pipe and its thickness is so the screws can be loosened, and equal to or greater than PC350 ductile iron pipe in sizes retightened with a torque-indicating of 16 inch and below and PC250 ductile iron pipe 18 wrench. During removal, the wedges inches and above. are held in place by retainer clips. / CAST IRON PIPE DEFLECTION I Grey iron pipe diameters are often larger than ductile The MEGALUG gripping wedges iron pipe diameters. The Series 1100 MEGALUG provide resiliency to your - --- restraint may be used with grey iron pipe having pipeline design. In addition standardized cast iron O.D. per AWWA C150 and to deflecting as much as V C151, and with pit cast Classes 'A" and "B" without modification. Use of the Series 1100 with pit cast grey iron Classes "C" and "D" - will require over sizing the MEGALUG. More information on this is explained in detail in "Connections Bulletin DI-1". MEGALUG r4W Takes the Load V On April 11, 1997 EBAA Iron performed a remark- able force demonstration of their series 1100 MEGALUG Joint Restraint. With the use of EBAA"s Series 1100 MEGALUG using a standard mechanical joint installation on 12 inch Ductile Iron Pipe, and a 80 Ton mo- tor crane, EBAA Iron lifted a D7 Caterpillar Track Type Tractor weighing in at 50,350 lbs. Along with this, the Series 1100 MEGALUG has been tested to over 700 PSI. Concluding that EBM's MEGALUGS can take the load. MëchäflicäFJöifltRëstraiflt SaflipIëSëcifióàtións (The text of the specifications below can be copied pasted from www.ebaa.com/downIoad/tL00Spec.D0C) Restraint devices for mechanical jcint fittings and appurtenances conforming to either ANSI/AWWA C111/ 1A21.11 or ANSI/AWWA C153/A21 53, shall conform to the following: Design Restraint devices for nominal pipe sizes 3 inch through 54 inch shall consist of t 1multiple gripping wedges incorporated into. a follower gland meeting the applicable requirements of ANSI/AWWA c110/A21.1c. 1The devices shall have a working pressure rating of 350 psi for 3-16 inch, 250 psi for 18-48 inch and 200 psi for the 54 inch. Ratings are for water pressure and must include a minimum safety factor of 2 to 1 in all sizes. Material Gland body, wedges and wedge actuating components shall be cast from grade 65- I ductile iron material in accordance with ASTM A536. For applications requiring restraint 30 inch and greater, an alternate grade of iron meeting the material requirements of ASTM A536 is acceptable, providing the device meets all end product performance requirements. Ductile iron gripping wedges shall be heat treated within a range of 370 to 470 BHN. Three (3) test bars shall be incrementally poured per production shift as per Underwriter's Laboratory (U.L.) Specifications and ASTM A536. Testing for tensile, yield and elongation shall be done in accordance with ASTM E8. Chemical and nodularity tests shall be performed as recommended by the Ductile ron Society, on a per ladle basis. Traceability An identification number consisting of year, day, plant and shift (YYDDD)(plant designation)(Shift number), shall be cast into each gland body. All physical and chemical test results shall be recorded such that they can be accessed via the identification number on the casting. These Material Traceability Records (MTR's) are to be made available, in hard copy, to the purchaser that requests such documentation and submits his gland body identification number. Production pieces that are too small to accommodate individual numbering, such as fasteners and wedges, shall be controlled in segregate inventory until such time as all quality control tests are passed. These component parts may then be released to a general inventory for final assembly and packaging. All components shall be manufactured and assembled in the United States. The purchaser shall, with reasonable notice, have the right to plant visitation at his/her expense. off nuts. Approvals Restraint devices shall be Listed by Underwriters Laboratories (3" through 24" inch size) and Approved by Factory Mutual (3" through 12" inch size). Mechanical joint restraint for ductile Iron pipe shall be Megalug Series 1103 produced by EBAA Iron Inc. or approved equal. MEGA-BOND® Restraint Coating System All wedge assemblies and related parts shall be processed through a phosphate wash, rinse and drying operation prior to coating application. The coating shall consist of a minimum of two coats of liquid thermoset epoxy coating with heat cure to follow each coat. All casting bodies shall be surface pretreated with a phosphate wash, rinse and sealer before drying. The coating shall be electrostatically applied and heat cured. The coating shall be a polyester based powder to provide corrosion, impact and UV resistance. Installation Mechanical joint restraint shall require The coating system shall be MEGA-BOND by conventional tools and installation EBAA Iron, Inc. or approved equal. Requests procedures per AWWA C600, while for approved equal must submit coating 11 retaining full mechanical joint deflection material and process details for review prior during assembly as well as allowing joint to bid. deflection after assembly. Proper actuation of the gripping wedges shallbeensuredwithtorquelimitingtwis- Lt -- I - Support Products for more information concerning these products please consult Me catalog or www.ebaa.com ries IIOOSD MHUALUG Restraint Existing, Mechanical Joints Series 1700 MEGALUG Restraint Harness For Push-On Bell Joints IIOOSDB 'plit MEOALUG Restraint 1. ur Mid Sp Ifl Applications Series IIOOHD Split MEGALUCJ Restraint Harness for Existing: Push-On Bells SECTION B-B M C.75 K2 ' J 0.125 -I SECTION A-A z 0 'U Series 1100 Submittal R€ Drawing 3 1103 4.48 2.27 4.06 0.62 9.06 0.750 6.19 7.6S 2 4 6.1 350 1104 5.92 2~27 4.90 0.75 990 0.875 750912 2 477350 6 1106 8.02 2.27 7.00 0.88 12.00 0.875 9.50 11.12 3 6 11.9 350 E8u1017231 915100 14150875 11.75 13.37 6 14.8 350 10 1110 12.22 237 11.20 1.00 16.20 0.875 14.00 15.62 6 8 23.9 350- L 12 1112 1432 2371330 125 18 0.875 16.25 178888312 350j 14 1114 16.40 2,69 15.44 1.50 20.94 0.875 18.75 2025 10 0 48.5 350 16 11161850 2691754156 22900875 21002250 12 12564 350 18 1118 20.60 2.69 19.64 1.63 25.00 0.875 23.25 24.75 12 12 63.1 250 L20_ 11-20 2270269 2174 169 2710 0.875 25502700 14 14 723 250 24 1124 26.90 3.20 25.94 1.81 32.64 0.875 30.00 31.50 16 16 133.1 250 LjU30 33293203217 225 38871125 3688 3912 20 201946 250-- 36 1136 39.59 3.20 38.47 2.25 45.17 1.125 43.75 46.00 24 24 234.0 250 Li 1142 4579 45 4467 388 5557 t375 5062 3348 28 28 536 0250j 48 1148 52.09 4.56 50.97 3.88 61.87 1.375 57.50 60.36 32 32 653.0 250 The Series 1100 MEGALUG joint restraint is designed for use on ductile iron pipe conforming to ANSI/AWWA C151/A21.51 (all thickness classes) when restraining mechanical joint pipe fittings. Clean the socket and the plain end. Lubrication and additional cleaning should be provided by brushing both the gasket and the plain end with soapy water or an approved pipe lubrication meeting 5. Tighten the bolts to the normal range of torque as indicated [3 inch 45-60 ft-lbs., 4-24 inch 75- 90 ft-lbs., 30-36 inch 100-120 ft-lbs., and 42, 48 and 54 inch 120-150 ftlbs.] While at all times maintaining approximately the same distance between the gland and the face of the flange at all points around the socket. This can be accomplished by partially tightening the bottom bolt first, then top bolt, next the bolts at either side, finally the remaining bolts. Repeat the process until all bolts are within the appropriate range of torque. In large sizes (30- 48 [and 54] inch), five or more repetitions may be required. The use of a torque-indicating wrench will facilitate this procedure. the requirement of ANSI/AWWA C111/A21.11, just prior to slipping the gasket onto the plain end for joint assembly. Place the gland on the plain end with lip extension toward the plain end, followed by the gasket. NOTE: In cold weather it is preferable to warm the gasket to facilitate assembly of the joint. 6. Tighten the torque limiting twist off nuts in a clockwise direction (direction indicated by arrow on top of nut) until all wedges are in firm contact with the pipe surface. Continue tightening in an alternating manner until all of the nuts have been twisted off. EBAA IRON Sales, Inc. P.O. Box 857, Eastland, IX 76448 Tel: (254) 629.1731 Fax: (254) 629.8931 (800) 433•1716 within US and Canada contact@ebaa.com vw.ebaa.com Insert the pipe into the socket and press the gasket firmly and evenly into the gasket recess. Keep the joint straight during assembly. Push the gland toward the socket and center it around the pipe with the gland lip against the gasket. Insert bolts and hand tighten nuts. Make deflection after joint assembly but before tightening bolts. 7. If removal is necessary, utilize the We inch hex heads provided. If reassembly is required, assemble the joint in the same manner as above, by tightening the wedge bolts to 90 ft-lbs. If the series 1100 restraint is removed from the pipe, be sure that all the collar bolts and wedges are in place before the restraint is reassembled. Steps 2-5 are requirements of AWWA. AWWA Standard C600 For More Information For more information about MEGALUG restraints call EBM today and request "EBAA connections Bulletin DI-1" concerning use of the MEGALUG restraint on grey iron pipe, or TBAA Connections Bulletin Dl-2" covering the background and operation of the MEGALUG system of restraint. Restraint Length Calculation" Software is available for Pc/windows applications. Support documenta- tion about the software can be found in EBM con- nections Bulletin PD-1 through PD-5". Blue Brute PRESSURE-RATED PVC PIPE , AWWA C900-16, CSA B137.3 ASTM 01784 Cell Class 12454 ANSI/NSF 61/14, UL 1285 [Ii!IiII] Gasket: ASTM F477 Joint: ASTM D3139 JMagIe DELIVERING GOOD WATER TO YOU Potable Irrigation Reclaim Sewer uI*1HIIlIiI Available Pipe Sizes (ClOD) 4IJ, 8'', 14'', 16'', 18'', 24'', 30" 36'', 42'', 48" Nominal Laying length= 20 feet (Laying length tolerances are is accordance with AWWA and CSA standards) Color: 0 Blue 0 Green 0 Purple White 305 psi (DR 14) 235 psi (DR 18) 200 psi (DR 21) 165 psi (DR 25) 125 psi (DR 32.5) 100 psi (DR 41) 80 psi (DR 51) Note: FM Approvals Pressure Class 185 psi for D8 and 250 psi for DFl14. 309 psi (DR 14) 235 psi (DR 18) 167 psi (DR 25) 50 year warranty only applicable to C900/Eagle Lac 900, C905, C909, AWWA C901 /C906. Check sssvw.jrneagle.camtwarranty for loll details. Blue Brute C900 PRESSURE-RATED PVC PIPE SUBMITTAL AND DATA SHEET L.... ....t.. ti. -'• 480 407 0.343 45 5 6.365 32 680 5.86 0.493 5.25 625 8.887 6.7 9.05 7.68 0.646 6.25 725 11.499 11.6 t 11.10 9.42 0.793 7.25 825 14.072 17.6 P 13.20 11.20 0.943 8.25 925 16.57 25.1 1 1740 14.85 1.' 7.25 875 21.637 4377 '0 2585 21.89 1J,- 075 1.25 3 950 9833 r'. - -------- IF 4 .23IIIIIIIIENt- 0.267 4.5 5.5 6.204 2,6 6 6.09 0.383 5.25 625 8,654 53 9.05 798 0.503 625 725 11.195 6' 1• 1110 9.79 0.617 725 820 13.699 139 F 13.20 11.65 0.733 825 925 16.125 197 t 5.30 13.50 0.850 6.5 8 18.603 26.75 [ 1740 15.35 0.967 7.25 8.75 21,135 34.86 1: 950 17.20 1.083 7.75 925 23.832 46.95 1, 21.60 19.06 1.200 9.75 1025 26.107 5422 'O 2580 22.76 1.433 975 11.25 31.089 5,97 1 3200 28.23 1 '78 11 .5 13.5 38.264 1 L - -____ - 75.30 13.75 0729 65 8 18.347 23.57 t 1740 15.64 0 829 7.25 8.75 MOW 3004 I 1950 17.53 0.929 7.75 925 23505 37.27 a 27.60 19.42 1.029 8.75 10.25 25.744 46.71 .8 25.80 23.19 1.229 9.75 1 '5 30.656 67.53 *I. 32.00 28.77 7.524 115 135 37.725 103.71 _18.30 34.43 1.824 13.25 8 44.753 152.16 T IET 4.80 439 012 45 55 6.045 18 690 631 0.276 525 25 8427 39 905 828 0.362 625 725 10.896 6.7 1. 1170 10.16 0.444 725 825 13.332 151 73.20 12.08 0.528 8.25 925 75.69 144 1530 1400 0.612 6.5 8 18.098 1940 17.40 7592 0.696 725 875 20.561 2536 1950 17.65 0.780 7.75 925 23.19 31.99 4 21.60 7977 0.864 875 10.25 25,395 39.4 Z 2580 23.67 7.032 9.75 11.25 30,239 56.98 • 32.00 2929 1.20 11.5 135 37.208 88.49 30.30 35.05 1.532 13.25 1525 44.134 128.41 P 4450 4073 1.70 155 7.5 5156 17602 5 50.80 49.49 L032 18 58.393 231.22 L. E I 1430 0171 65 17.799 5.14 1' 140 1627 0.535 725 0'S 20.219 1863 E 79.50 1823 0.600 775 925 22.808 2475 4• 21.60 20.19 0.665 875 1225 24.973 30.54 Z 2580 2412 0.794 9.75 1125 29.734 4.4 Il 9 32.00 29.91 G985 11.5 13.5 36582 68.45 3830 35.80 1178 1325 15.25 43.383 99.22 8 080 47.49 1.563 16.5 18.5 57.399 1784 ~0,~ JM agIe NQM~~/ DELIVERING GOOD WATER TO YOU PIPE SIZE AVERAGE 0 0 NOM I 0 MIN I APPROX E APPROX E APPROX 0 APPROX WGT (IN) 9N) (IN) , ..(IN) - (IN) (LBS/PT) ............ - i. i.ii I - .., ...... ! 15.30 14.52 0.375 6.5 2 17.509 12.01 17.40 16.51 0.424 7.25 8.75 19.992 15.63 I 79.58 18.50 0.476 7.75 9.25 22.555 19.72 'Z• 21.60 20.49 5,527 8.75 10.25 24.692 24.31 Z 2500 2448 0.629 075 1125 29.397 3510 'I 3200 3035 0,780 115 135 36.163 5465 t 38.30 36,30 0.934 13,25 15.25 42885 78.97 I' 44.50 42.18 7' 15.5 17.5 55.708 172.19 J 5090 4914 ' 16.5 12 .56736 14210 V wmc_ 32.00 30.67 0 11.5 13.0 ---------- 35.836 44.08 30.30 36.71 0.7., 13.25 15.20 42.478 1 64.32 P 44.50 42.65 0.872 15,5 17.5 49.652 88.10 50.80 49.69 0.996 16.0 .....06.217 115.79 Product Standard: ANSI/AWWA C900-16 CSA B137.3 (DR 18, 25, 4-18; DR 14, 4-12") Pipe Compound: ASTM D1784 Cell Class 12454 Gasket: ASTM F477 Integral Bell Joint: ASTM D3139 Certifications: ANSI/NSF 61 ANSI/NSF 14* UL 1285 (DR 14,18,25, up to 24) FM 1612* (DR 14/DR 18; 4-12"), CSA B137.3* Note: FM Approvals Pressure Class 185 psi for DR 18 and 250 psi for DR 14. Nominal Laying Length: 20 feet (Laying length tolerences with AWWA and/or CSA standards) Installation: JM Eagle' Blue Brute Installation Guide Manning Coefficient (n) = 0.009• Hazen-Williams Coefficient (c) = 150 *Please call regarding availability. D9 E, O.D. E_ Assembly Mark l.D.: Inside Dameter E,: Distance between 1st Insertion/ 0.0.: Outside Diameter Assembly Mark to the end of spigot. 1: Wall Thickness E2: Distance between 2nd Insertion/ D: Bell Outside Diameter Assembly Mark to the end of spigot. APPwvm LISTED This information may have been updated. Please visit www.jmeagle.com for all updated information and warranty details. CUSTOMER SERVICE:1.800.621.4404 THIS PRODUCT IS MADE IN AMERICA PRINTED JUNE 2018 REV21 \%JPO ROEMER CONNECTIONS (FDC) ModellSees Noi TTER FIRE PRO. EXPOSED FIRE DEPT. INLET 571 O5734j SERIES Member of Morris Group Internationaltm CONNECTIONS-CLAPPER TYPE SPECIFICATIONS TWO-WAY WITH SINGLE CLAPPER, 300 PSI RATED Cast brass two-way inlet body, swing clapper and pin lug swivel. Back or angle outlet as selected by model number. Lettering as selected. Size 4" x 2-1/2" x 2-1/2". TWO-WAY WITH DOUBLE CLAPPER, 175 PSI RATED Cast brass two-way inlet body, drop clappers and pin lug swivels. Size and outlet as selected by model number. Lettering as selected. MODEL SELECTION TWO-WAY WITH SINGLE CLAPPER Ii 5710 Back Outlet (UL Listed) 4FMOo- LJ 5715 Angle Outlet (UL Listed) AFMIP- TWO-WAY WITH DOUBLE CLAPPER U 5721 Back Outlet U 5722 Back Outlet U 5723 Back Outlet U 5724 Back Outlet Ii 5731 Angle Outlet lj 5732 Angle Outlet U 5733 Angle Outlet U 5734 Angle Outlet Note: Refer to Model Dimensional Chart for UL & FM Listing C®US UL File #EX4078 <1> USTED Model #S201 B APPROVED MODEL 5710 (Shown) PRODUCT OPTIONS FINISHES: U -B Polished Brass U -C Rough Chrome Plated Body U -D Polished Chrome Plated THREADS: U N.S.T. U Other_ LETTERING AVAILABLE: U AUTO. SPKR. U STANDPIPE Call Potter Roemer - Fire Pro for current listings and approvals. Dimensions are subject to manufacturer's tolerance and may change without notice. Potter Roemer- - FIRE EQUIPMENT MANUFACTURERS' POTTER ROEMER/FIRE PRO Headquarters: Also in: Fire Pro assumes no responsibility for use of void or ASSOCIATION _____________ - P.O. Box 3527 New York (800) 526-4592 superceded data. © Copyright Potter Roamer- Fire Pro, Member of Moms Group International ' Please visit p000erroemer.com for most current specifications - - no ("\ P E . _____9 city of Industry, CA Chicago (800) 547-3473 91744 U.S.A. Atlanta (800) 762-0542 Los Angeles Area Miami (866) 961-3473 L. 51105134 SERIES Date: 12/11/18 NFPA . 800-366-3473 Dallas (866) 644-3473 626-855-4890 www.potterroemer.com WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov POTTER r/\\ \ ONECTIONS (FD Mo o. NIRE PRO EXPOSED FIRE DEPT. INLET 5710-5734 I SERIES Member of Morris Group International- Lc2.NECTIONS-C LAPP ER TYPE MODEL DIMENSIONS TWO-WAY WITH SINGLE CLAPPER UL Listed File #EX4078 MODEL 5710-5715 Model #S201 B APPROVED TWO-WAY WITH DOUBLE CLAPPER Outlet Approvals Outlet Approvals Size #EX3314 A B C D Back Model No. c®us LISTED #EX3314 Angle Model No. c®us LISTED 5721 Yes 5731 Yes 4x2-1/2x2-1/2 7-1/2 11-1/2 8-1/2 11-1/2 5722 Yes 5732 Yes 6 x 2-1/2 x 2-1/2 9-1/2 1 10-1/2 9 10-3/4 5723 Yes 5733 Yes 4 x 3 x 3 9-1/2 11-1/2 9-1/2 11 5724 Yes 5734 Yes 6 x 3 x 3 10 11 10-1/2 11 71/4M MODEL 5721 - 5734 UL Listed File #EX3314 Model #A105 Call Potter Roemer - Fire Pro for currant listings and approvals. Dimensions are subject to manufacturers tolerance and may change without notice. Potter Roamer- Fire Pm assumes no responsibitity for use of void or superceded data. © Copyright Potter Roamer- Fire Pro, Member of Moms Group International re Please visit potterroemer.com for most current specifications. 51105134 SERIES Date: 12/11/18 - Y r. A. FIRE EQUIPMENT M AN U FACTU S RED ASSOCIATION 0IFSA ___________ c 1 ••J (NAFED O\ % f•,ASPE NFPA POTTER ROEMERJFIRE PRO Headquarters: Also in: P.O. Box 3527 New York (800) 526-4592 City of Industry, CA Chicago (800) 547-3473 91744 U.S.A. Atlanta (800) 762-0542 Los Angeles Area Miami (866) 961-3473 800-366-3473 Dallas (866) 644-3473 626-8554890 www.potterroemer. corn MEGALUG Series 1100 Mechanical Joint Restraint for Ductile Iron Pipe 3 1103 6.1 3 0 350 L1 04 77 3 0 350 6 1106 11.9 30 350 ET 1108 148 30 350 TI 10 1110 23.9 3 0 350 12 111231 23°350] 14 1114 48.5 2 0 350 1116 564 20 350 j 18 1118 63.1 11/20 250 [ 21) 1120 723 1½°250 24 1124 133.1 11/20 250 30 1 194 25O 36 1136 234.0 1° 250 11425360 10 2501 48 1148 653.0 10 250 54 1154 7002 05 200T MadeIn U.S. Patent Nos. 4092036, 4627774, 4779900, 4896903, 5544922 The USA Features and Applications: Sizes 3 inch through 54 inch Constructed of ASTM A536 Ductile Iron Torque Limiting Twist-Off Nuts MEGA-BOND® Restraint Coating System For more information on MEGA-BOND, refer to www.ebaa.com The Mechanical Joint Follower Gland is incorporated into the restraint Heavy Duty thick wall design Support Products Available: Split repair style available 3 inch through 48 inch. EBAA Series IIOOSD Solid restraint harness available for push-on pipe bells. EBAA Series 1700 Split restraint harness available for existing push-on bells. EBAA Series IIOOHD All MEGALUG and related restraint products can be furnished as packaged accessories complete with appropriate restraint, gasket, lubrication, and bolt- ing hardware For use on water or wastewater pipe- lines subject to hydrostatic pressure and tested in accordance with either AWWA C600 or ASTM D2774 MEGALUG: THE PRODUCT OF PREFERENCE SINCE 1984 Since 1984, engineers and contractors designing and installing vater and wastewater pipelines and systems have come to rely )fl the EBAA Series 1100 MEGALUG Mechanical Joint Restraint s the "Product of Preference" for effectively and economically estraining ductile iron pipe connections above or below ground. MEGALUG Mechanical Joint Restraints replace external re- ;traints such as cumbersome concrete thrust blocks and corrod- ble metal tie rods creating a quicker, safer and more economical nstallation. Major testing laboratories agree as the 3" through 24" sizes are Underwriters Laboratories (UL) listed, and the 3" through 12" sizes are Factory Mutual (FM) approved. For use on all classes of ductile iron pipe (PC350 through PCI50 and CL56 through CL50), for practically any application including valves, hydrants and pipe, the MEGALUG \lechanical Joint Restraint effectively and safely performs wit.out damage to the pipe or cement linings. THE MEGALUG GRIPPING WEDGE... PERFORMANCE PROVEN The wedge style MEGALUG design reacts the amount of force acting on the joint. When each wedge is set, the wedge teeth )enetrate the pipe's outer surface, and he wedge does not move on the pipe. here is very little change in this interface intil the wedge movement begins inside he pocket of the main casting. Once the vedge starts moving, the formation of the )uttreSS begins. This "dam" of material (the wedge mpression) is cold formed as the wedging ction continues. If the force of pressure cting on the joint is released, the wedge noves back to near its original position. his engages the reserve-controlled move- nent or "RCM". The wedge is then ready Or another round. After the wedge has moved to the back ILl o 1- Max pressure of Movement I IL. causes I - wedges to increase 7 Max movement grip Of Rated prescore t.0 ( Wedge movement begins I Normal operating pressure D (/) Ui MOVEMENT of the pocket at the maximum pressure or load, the wedge buttress are in shear. The maximum movement is about 0.3 inch through the thirty-six inch size and 0.4 inch for forty-two and forty-eight inch. The RCM is available even with severe cyclic loads. This has been :ested to very high-pressure differentials and the wedge impressions look the same as if a single test had been performed. Typically, the depth of pipe wall pen- etration, or wedge impression at around 25,000 pounds of force per wedge (200 PSI on a six inch and 150 PS on a twelve inch) is 0.03". Finally, at roughly twice that force the penetration is arctj"d 0.05" At these high pressures, there is no affect on the design thickness of ductie iron pipe made according to AWWA C150. The lack of damage to the cement lining clearly indicates that the thrust load is primarily longitudinal. This ability to move in the pocket allows for angular flexibility as well as longiudi- nal flexibility. THE ORIGINAL PATENTED allowed by the GRIPPING WEDGES ,mechanical joint uring installation, it can also deflect Since 1964 EBAA Iron has responded after assembly: aggressively to the needs of the Sizes of 12" and below water industry for better solutions - are capable of up to 3 to joint restraint problems - thus the degrees of deflection after development of the family of self installation (depending on the actuating MEGALUG wedge action preset deflection.) restraints. The 14" and 16" sizes are capable of 2 degrees deflection. TOOLS The 18" through 24" sizes are MEGALUGS install using an ordinary capable of 1.5 degrees deflection. wrench (box, ratchet, or air-driven), The 30" through 48" sizes are capable of because the torque-limiting, twist- 1 degree deflection. off nuts automatically shear during The 54" size has a 0.5 degree deflection. tightening when the proper torque is reached. The same 11/4 wrench STEEL PIPE U used to tighten the T-bolts on the The 1100 Series MEGALUG can be used to restrain 4" through 24" sizes can be used 3" - 8" SCH 40 or 80 steel pipe when joining to to tighten and shear the twist off mechanical appurtenances. It can also be used on nuts in all sizes. If removal becomes steel pipe in all sizes if the pipe's outside diameter is necessary, a 5/8 hex head remains the same as the ductile iron pipe and its thickness is so the screws can be loosened, and equal to or greater than PC350 ductile iron pipe in sizes retightened with a torque-indicating I of 16 inch and below and PC250 ductile iron pipe 18 wrench. During removal, the wedges I I ' inches and above. are held in place by retainer clips. / CAST IRON PIPE DEFLECTION Grey iron pipe diameters are often larger than ductile The MEGALUG gripping wedges iron pipe diameters. The Series 1100 MEGALUG provide resiliency to your ., restraint may be used with grey iron pipe having - - pipeline design. In addition standardized cast iron O.D. per AWWA C150 and to deflecting as much as C151, and with pit cast Classes "A" and "B" without modification. Use of the Series 1100 with pit cast grey iron Classes "C" and "D" will require over sizing the MEGALUG. More information on this is explained in detail in ) . "Connections Bulletin DI-1". MEGALUG Takes the Load On April II, 1997 EBAA Iron iperformed a remark- able force demonstration of their series 1100 MEGALUG Joint Restraint. With the use of EBAA's Series 1100 MEGALUG using a standard mechanical joint installation on 12 inch Ductile Iron Pipe, and a 80 Ton mo- tor crane, EBAA Iron lifted a D7 Caterpillar Track Type Tractor weighing in at 50,350 lbs. Along with this, the Series 1100 MEGALUG has been tested to over 700 PSI. Concluding that EBA's MEGALUGS can take the load. for more information concerning these products please consult the catalog or www.ebaa.com ies-IIOOSD VIEGALUG Restraint dsting Mechanical Joints Series 1700 MEGALUG Restraint Harness For Push-On Bell Joints MecIianicaIJOintKestraint5ampIe5peCiTiCatiOns - (The text of the specifications below can be copied pasted from www.ebaa.com/downIoad/tL0OSpec.DOC) Restraint devices for mechanical joint fittings and appurtenances conforming to either ANSI/AWWA C111/ A21.11or ANSI/AWWA C153/A21.53, shall conform to the following: Design Traceability off nuts. I - Restraint devices for nominal pipe sizes An identification number consistir-g of 3 inch through 54 inch shall consist of year, day, plant and shift (YYDDD):plant Approvals multiple gripping wedges incorporated into designation)(Shift number), shall be cast Restraint cevices shall be Listed by a follower gland meeting the applicable into each gland body. Underwriters Laboratories (3" through 24" requirements of ANSI/AWWA C110/A21.10. inch size) afid Approved by Factory Mutual All physical and chemical test results (3" through 12" inch size). The devices shall have a working pressure shall be recorded such that they can be rating of 350 psi for 3-16 inch, 250 psi for accessed via the identification number on Mechanical joint restraint for ductile 18-48 inch and 200 psi for the 54 inch. the casting. These Material Traceability Iron pipe shall be Megalug Series 1100 Ratings are for water pressure and must Records (MTR's) are to be made available, produced by EBAA Iron Inc. or approved include a minimum safety factor of 2 to L ii in hard copy, to the purchaser that requests equal. all sizes. such documentation and submits his glands body identification number. MEGA-BOND® Restraint Coating System Production pieces that are too small to All wedge assemblies and related parts accommodate individual numbering, shall be p-o. through a phosphate such as fasteners and wedges, shall be wash, rinse and drying operation prior controlled in segregate inventory until to coating application. The coating shell such time as all quality control tests are consist of minimum of two coats of liquid passed. These component parts may then thermoset epoxy coating with heat cure to be released to a general inventory for final follow each coat. assembly and packaging. All casting bodies shall be surface All components shall be manufactured pretreated with a phosphate wash, rinse and assembled in the United States. The and sealer before drying. The coating shall purchaser shall, with reasonable -otice, be electrostatically applied and heat cjred. have the right to plant visitation at his/her The coatirigshall be a polyester based expense. powder to-provide corrosion, impact and U resistance. Installation Mechanical joint restraint shall require The coating system shall be MEGA-BOND b conventional tools and installation EBAA Iron, Inc. or approved equal. Request procedures per AWWA C600, while for approved equal must submit coating retaining full mechanical joint deflecticn material and process details for review priO during assembly as well as aIIowi-g joint to bid. deflection after assembly. Material Gland body, wedges and wedge actuating components shall be cast from grade 65- ,45-12 ductile iron material in accordance with ASTM A536. For applicatiors requiring restraint 30 inch and greater, an alternate grade of !i ron meeting the material requirements of ASTM A536 is acceptable, providing the device meets all end product performance requiremen:s. Ductile iron gripping wedges shall be heat treated within a range of 370 to 470 BHN. Three (3) test bars shall be incrementally poured per production shift as per Jnderwriter's Laboratory (U.L.) Specifications and ASTM A536. Testing for tensile, yeld and elongation shall be done in accordance with ASTM E8. chemica and nodularity tests shall be performed as recommended by th Ductile Proper actuation of the gripping wedges Iron Society, on a per ladle basis. shall be ensured with torque limiting twist Support Products "Series IIOOSDB plit MEGA-LUG Restraint For Mid -Span Applications Series IIOOHD Split MEGALUG Restraint - Harness for Existing ?Lsh-On Belle _ F-0.75 ho Submittal Reference Drawing _ 3 1103 4.48 2.27 4.06 0.62 9.06 0.750 6.:9 7.69 2 4 6.1 350 1104 592 22, 490 075990 0675 750 912 2 4 7 7350 6 1106 8.02 2.27 7.00 0.88 12.00 0.475 9.50 11.12 3 6 11.9 350 ii0iTüEii7 231915 100 1415 0675 1175 1337 4 6 10 1110 12.22 2.37 11.20 1.00 16.20 0.675 14,00 15.62 6 8 23.9 350 11121432 23i33O 1251830 --D.-;'-'75 1625 1788 8 - 8 3123501 14 1114 16.40 26 15.44 1.50 20.94 3.675 18.75 20.25 10 10 48.5 350 E1116 1850 2.6-9 1754 156 2290 075 2100 2250 12 12 564 350 18 1118 20.60 2.6 19.64 1.63 25.00 O.75 23.25 24.75 12 12 63.1 250 Lo 1120 2270 269 2174 169 2710 075 2550 2700 14 14 723 250] 24 1124 26.90 32' 25.94 1.81 32.64 0.75 30.00 31.50 16 16 133.1 250 ffi 1130 33.29 32 32.17 2.25 38.87 1125 36.88 39.12 20 20 194.6 250 36 1136 39.59 3.20 38.47 2.25 45.17 1.125 43,75 46.00 24 24 234.0 250 L 1 1142 45.79 4.56 44.67 3.88 .55.57 1375 5062 5348 2828 536O 48 1148 52.09 4.58 50.97 3.88 61.87 1.375 57.50 60.36 32 32 653.0 250 54 1154 58.824.5733386.401375 63.20 66.33 361.: 36 70-3.3 200 ; ___sI e' t- 10O 1PAU h Hhft ncbued o pliri E S1 Mh: ariL IL JeeLL 1I I pro4ldeh I 0 iJ rllih th uh 4 ih \1EcLLt( rhtra ntb a e ar ru rJ er 1eho\e re zee t a ac 6 'C,datH,thFure rafl n factor ip 0 - o cii rsi b usd E.tr Itnh J bolto arc pr dci .ih tc 42 dl .48cia,dE1 1r1i.. r04r o rpf~sri ine ç pck [4 to f o I1ta e a r a jpht ( L1O rrh rnr4 it I 1 plc & oe the rd s ahoy n trrt S 1 JO LLJO ri pore m4 d2 of F fr rii palr 1JL a t n ri1rtn nt Th ifcr nrmg A5T 1 AUTh The L re h4 IL a ha rj r i prratn I r e. ef37 [a 10 P.1id t . L n 'dnH [t d TINSiAD APPRI ~,es f AIJ ic I r c7 can U ariter r rcr Ich)le is i es 3 irtohthroui 2hmn *cr4 MatJ S FA 1T1 pnJJ fp ri d tiI restnintcn he on rn n pa if th ppi ctp4 r I i sin iitn nroLJd acr inedad Fore rif n on pe f the 4 stf n rrcn rp 1 or rinctros ut4 r L The Series 1100 MEGALUG joint restraint is designed for use on ductile iron pipe conforming to ANSI/AWWA C151/A21.51 (all thickness classes) when restraining mechanical joint pipe fittings. 2. Clean the socket and the plain end. Lubrication and additional cleaning should be provided by brushing both the gasket and the plain end with soapy water or an approved pipe lubrication meeting Tighten the bolts to the normal range of torque as indicated [3 inch 45-60 ft-lbs., 4-24 inch 75- 90 ft-lbs., 30-36 inch 100-120 ft-lbs., and 42, 48 and 54 inch 120-150 ftlbs.] While at all times maintaining approximately the same distance between the gland and the face of the flange at all points around the socket. This can be accomplished by partially tightening the bottom bolt first, then top bolt, next the bolts at either side, finally the remaining bolts. Repeat the process until all bolts are within the appropriate range of torque. In large sizes (30- 48 [and 54] inch), five or more repetitions may be required. The use of a torque-indicating wrench will facilitate this procedure. the requirement of ANSI/AWWA CIII/A21.11, just prior to slipping the gasket onto the plain end for joint assembly. Place the gland on the plain end with lip extension toward the plain end, followed by the gasket. NOTE: In cold weather it is preferable to warm the gasket to facilitate assembly of the joint. 6. Tighten the torque limiting twist off nuts in a clockwise direction (direction indicated by arrow on top of nut) until all wedges are in firm contact with the pipe surface. Continue tightening in an alternating manner until all of the nuts have been twisted off. EBAA IRON Sales, Inc. P10. Box 857, Eastland, TX 16448 Tel: (254) 6291131 Fax: (254) 629-8931 (800) 433-1716 within US and Canada contact@ebaa,com unAIfih2nnn1 Insert the pipe into the socket and press the gasket firmly and evenly into the gasket recess. Keep the joint straight during assembly. Push the gland toward the socket and center it around the pipe with the gland lip against the gasket. Insert bolts and hand tighten nuts. Make deflection after joint assembly but before tightening bolts. 7. If removal is necessary, utilize the 5/8 inch hex heads provided. If reassembly is required, assemble the joint in the same manner as above, by tightening the wedge bolts to 90 ft-lbs. If the series 1100 restraint is removed from the pipe, be sure that all the collar bolts and wedges are in place before the restraint is reassembled. Steps 2-5 are requirements of AWWA. AWWA Standard C600 For More Information For more information about MEGALUG restraints call EBAA today and request EBAA connections Bulletin Dl-1" concerning use of the MEGALUG restraint on grey iron pipe, or "EBAA Connections Bulletin Dl-2" covering the background and operation of the MEGALUG system of restraint Restraint Length calculation" Software is available for PC/Windows applications. Support documenta- tion about the software can be found in "EBAA Con- nections Bulletin PD-1 through PD-5". Blue Brute PRESSURE-RATED PVC PIPE lie AWWA C900-16, CSA B137.3 ASTM D1784 Cell Class 12454 ANSI/NSF 61/14, UL 1285 c900 Gasket: ASTM F477 Joint: ASTM D3139 ~O,~ JMagIe NQMA~~ DELIVERING GOOD WATER TO YOU rIi11I. 4 tj Potable Irrigation Reclaim Sewer III *II'R1IIIII Available Pipe Sizes (ClOD) 419,619, 811, 16", 18", 20", 24", 30", 36", 42", 48" Nominal Laying length = 20 feet (Laying length tolerances are in accordance with AWWA and CSA standards) Color: 0 Blue 0 Green 0 Purple Lii White 305 psi (DR 14) 235 psi (DR 18) 200 psi (DR 21) 165 psi (DR 25) 125 psi (DR 32.5) 100 psi (DR 41) 80 psi (DR 51) Note: FM Approvals Pressure Class 185 psi for DRIa and 250 psi for DR14. 309 psi (DR 14) 1 235 psi (DR 18) 167 psi (DR 25) 50 year warranty only applicable to COOS/Eagle Lsc 900, C905, C909, AV/WA C9011C906. Check wsra.jmeagle.cornarranly for full details. Blue Brute C900 PRESSURE-RATED PVC PIPE SUBMITTAL AND DATA SHEET ~O,~ JMagIe N, ta b ~W~ DELIVERING GOOD WATER TO YOU LLIhi hil1 I - -. -- ii1 1 I T1 [ - 2ti00ti*a I 4.80 407 0343 45 55 6.365 3.2 1530 14.52 0.373 65 8 17.598 12.01 6.90 5.86 0.493 5.25 625 8.857 6.7 ( 17.40 16.51 0.424 725 8.75 19.982 15.63 ' 9.05 7.68 0.646 6.25 7.25 11.499 11.6 I 1950 18.50 0476 7.75 925 22.555 19.72 1' 11.10 9.42 0.793 7.25 8.25 14.072 17.6 e 21.60 20.49 0527 8.75 10.25 24.691 24.31 13.20 11.20 0.943 8.25 925 1657 25.1 Z 25.80 24.48 0.629 0,75 11.25 29.397 35.10 17.40 14.85 1.242 7.25 8.75 21.637 43,77 t. 32.00 30.35 0.780 11.5 3.5 36.163 54.65 25.80 2189 I 843 9.75 11 .25 31 958 9833 1 38.30 36.30 0.934 13.25 1525 42.885 78.97 .. I 44.50 42.18 1.085 15.5 17.5 50.108 108.19 - a561ll0m1swen0 - I o 50.80 48.14 1.239 16.5 18.5 56.736 142.10 4.80 423 0.267 4.5 55 6204 26 L'......... 1 6.90 609 0.383 5.25 6.25 8.654 5.3 [ - '8i18t19l. . 9.05 7.98 0.503 6.25 7.25 11.195 9.2 *t. 32.00 30.67 0627 11.5 13.5 35.036 44.08 1' 11.10 9.79 0.617 7.25 8.25 13.699 13.9 *1 38.30 36.71 0.751 13.25 15.25 42.478 64.32 F 13.20 11.65 0.733 8.25 9.25 16.125 19.7 E 44.50 42.65 0.872 15.5 17.5 49.652 88.10 15.30 13.50 0.850 6.5 8 18,603 26.75 1' 5080 4969 0.996 16.5 18.5 56.217 115.79 I* 17.40 15.35 0.967 7.25 8.75 21.135 34.86 Product Standard: ANSI/AWWA C900-16 E 1950 1720 1.083 775 925 23.832 4895 4. 21.60 19.06 1.200 8.75 10.25 26.107 54.22 CSA B137.3* (DR 18, 25, 4-18; DR 14, 4-12') *0 25.80 22.76 1,433 9.75 11,25 31.089 77.97 Pipe Compound: ASTM D1784 Cell Class 12454 32.00 2823 1.778 11.5 13,5 38,264 117,82 Gasket: ASTM F477 Integral Bell Joint: ASTM D3139 - Certifications: ANSI/NSF 61, ANSI/NSF 14* 15.30 1375 0.729 65 8 18.347 23.07 UL 1285 (DR 14, 18, 25, up to 24'), FM 1612* (DR 14 / DR 18; 4-12"), CSA B137.3* 1 17.40 15,64 0.829 7.25 8.75 20.097 30,04 Note: FM Approvals Pressure Class 185 psi for DR 18 and 250 psi for DR 14. . 19.50 17.53 0.929 7.75 9.25 23.505 37,27 Nominal Laying Length: 20 feet 9• 21,60 19,42 1,029 8,75 10.25 25,744 46,71 'Z 2560 23.19 1.229 9.75 11:25 30.656 67.53 (Laying length tolerences with AWWA and/or CSA standards) 't. 32.00 28,77 1,524 11.5 13.5 37.725 103.71 Installation: JIM Eagle* Blue Brute Installation Guide *t 38.30 L - 34.43 -....... 1,824 1325 1525 44.753 152.16 Manning Coefficient (n) = 0.009• Hazen-Williams Coefficient (c) = 150 [ - ' Please call regarding availability. 4.80 4.39 0.192 4.5 5.5 6,045 1.9 6,93 6,31 0.276 525 625 8,427 3.9 fl 9.05 8.28 0.362 625 725 10.896 6.7 4. 11,10 10.16 0.444 7.25 8.25 13.332 10.1 I 13.20 12.08 0.528 8.25 9.25 15.69 14.4 E 5.30 14.00 062 6.5 8 18.098 19.48 /__*\\'.\ \\\\ \\'..\. \\'S\ •\\\ *'7 '*\\'----, Li 17.40 15,92 0.696 7.25 8.75 20.561 25.38 19.50 17.85 0.780 7.75 9.25 23.19 31.99 T / / 0. D. 1. D. 39,46 21.60 19.77 0.864 8.75 10,25 25.395 Z 25.80 23,61 1.032 9.75 11.25 30.239 56.60 Assembly Mark 32.00 29.29 1.280 11.5 13.5 37.200 00,49 5 38.30 35,05 1.532 13.25 15.25 44.134 128.41 I.D.: Inside Dameter E,: Distance between 1st Insertion! 44.50 40.73 1.780 15.5 17.5 51.56 176,02 A O.D.: Outside Diameter Assembly Mark 0 e en o spigot. 5080 4649 2.032 16.5 18.5 58.393 23122 T: Wall Thickness E2: Distance between 2nd Insertion! [......_. , - - I D9: Bell Outside Diameter Assembly Mark to the end of spigot. 1535 1430 0.471 65 8 17,799 15.14 17.40 16.27 0.535 7.25 8.75 20.210 19,63 10.50 18.23 0.600 7.75 9.25 22,808 24.75 2 60 5.80 fl 32 1. ,00 ::.: :.: :.;: .:: :.: .54 ::. 29.91 0,985 11,5 13,5 36.582 68.45 Sf110951 "''' LISTED 1 38,30 35.80 1,178 13.25 15.25 43,383 99.22 I 50.80 47,49 1,563 16.5 18.5 57.399 178.49 This information may have been updated. Please visit www.jmeagle.com for all updated information and warranty details. CUSTOMER SERVICE:1.800.621.4404 THIS PRODUCT IS MADE IN AMERICA PRINTED JUNE 2018 REV21 \\\\NF1PEPPo /POTTER ROEMER i CONNECTIONS (FDC) . EXPOSED FIRE DEPT. INLET Member of Morris Group tnternationavu CONNECTIONS-CLAPPER TYPE Model/Series No., 5710-5734 SERIES SPECIFICATIONS TWO-WAY WITH SINGLE CLAPPER, 300 PSI RATED Cast brass two-way inlet body, swing clapper and pin lug swivel. Back or angle outlet as selected by model number. Lettering as selected. Size 4" x 2-1/2" x 2-1/2". TWO-WAY WITH DOUBLE CLAPPER, 175 PSI RATED Cast brass two-way inlet body, drop clappers and pin lug swivels. Size and outlet as selected by model number. Lettering as selected. MODEL SELECTION TWO-WAY WITH SINGLE CLAPPER U 5710 Back Outlet (UL Listed) 1 F U 5715 Angle Outlet (UL Listed) FM Ili- TWO-WAY WITH DOUBLE CLAPPER Ii 5721 Back Outlet U 5722 Back Outlet U 5723 Back Outlet U 5724 Back Outlet U 5731 Angle Outlet U 5732 Angle Outlet U 5733 Angle Outlet U 5734 Angle Outlet Note: Refer to Model Dimensional Chart for UL & FM Listing PRODUCT OPTIONS FINISHES: U -B Polished Brass U -C Rough Chrome Plated Body U -D Polished Chrome Plated THREADS: U N.S.T. U Other LETTERING AVAILABLE: U AUTO. SPKR. U STANDPIPE Call Potter Roemer - Fire Pro for current listings and - __ I POTTER ROEMER/FIRE PRO I approvals. Dimensions are subject to manufacturer's tolerance and may change without notice. Potter Roemer- FIRE EQUIPMET N MANUFACTURERS ASSOCIATION 0I'FSA /41\ Headquarters: Also In: Fire Pro assumes no responsibility for use of void or - P.O. Box 3527 New York (800) 526-4592 I superceded data. © Copyright Potter Roemer- Fire Pro, city of Industry, CA Chicago (800) 547-3473 Member of Morris Group International "" Please visit potterroemer.com for most current specifications. - - 91744 U.S.A. Atlanta (800) 762-0542 I Los Angeles Area Miami (866)961-3473 I 51105134 SERIES Date: 12/11/18 NAFED . NFPA 800-366-3473 Dallas (866) 644-3473 I 626-855-4890 www.potterroemer.com I £ WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov I POTTER - Model/Series No. N\\\NF/PE CONNECTIONS (FDC) 5710-5734 DJ9Q EXPOSED FIRE DEPT. INLET CONNECTIONS-CLAPPER TYPE Member of Morris Group International- MODEL DIMENSIONS TWO-WAY WITH SINGLE CLAPPER I, I UL Listed File 4EX4078 MODEL 5710 - 5715 Model #S201B APPROIJHI TWO-WAY WITH DOUBLE CLAPPER Outlet Approvals Outlet Approvals Size A #EX3314 B C D Back Model No. c®us LISTED #EX3314 Angle Model No. cus LISTED 5721 Yes 5731 Yes 4x2-1/2x2-1/2 7-1/2 11-1/2 8-1/2 11-1/2 5722 Yes 5732 Yes 6 x 2-1/2 x 2-1/2 9-1/2 10-1/2 9 10-3/4 5723 Yes 5733 Yes 4 x 3 x 3 9-1/2 11-1/2 9-1/2 11 5724 Yes 5734 Yes 6 x 3 x 3 10 11 10-1/2 11 7-1I4 MODEL 5721 - 5734 UL Listed File #EX3314 Model #A105 Call Potter Roemer - Fire Pro for current listings and - _ POTTER ROEMER/FIRE PRO FIRE EQUIPMENT ____ approvals. Dimensions are subject to manufacturer's ASS UCIATION P.O. Box 3527 New York (800) 526-4592 Fire Pro assumes no responsibility for use of void or - superseded data. © Copyright Potter Roemer- Fire Pro, City of Industry, CA Chicago (800) 547-3473 tolerance and may change without notice. Potter Roemer- ,,AlfIuiI\ MANUFACTURERS _P1FSA Headquarters: Also in: Member of Morris Group International 0i Please visit 91744 U.S.A. Atlanta (800) 762-0542 - - potterroemer.com for most current specifications. J (°\ /)\ . Los Angeles Area Miami (866) 961-3473 O N4FDj 800-366-3473 Dallas (866) 644-3473 51105134 SERIES Date: 12/11/18 NFPA . 626-8554890 v,l,yi,,potterroemercom