HomeMy WebLinkAbout5781 VAN ALLEN WAY; ; FPC2018-0392; PermitCity of PER]CT REPORT Carlsbad Print Date: 10/05/2022 Permit No: FPC2018-0392 Job Address: 5781 VAN ALLEN WAY, CARLSBAD, CA 92008-7321 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2121304400 Track #: Applied: 12/04/2018 Valuation: $0.00 Lot #: Issued: 12/14/2018 Occupancy Group: Project #: Finaled Close Out: 12/05/2019 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check #: INSPECTOR: Salcedo, Felix Plan Check #: Wong, Cindy Fieri, Dominic Project Title: Description: THERMO FISHER -FIRE ALARM STROBES & HORNS IN BSL2 LAB & COPY CENTER Applicant: FPContractor: JOHNSON CONTROLS SECURITY SOLUTIONS JOHNSON CONTROLS SECURITY SOLUTIONS LLC LLC - DO NOT USE MALCOLM D'COSTA 3870 MURPHY CANYON RD, 4* 140 3870 MURPHY CANYON RD, 4* 160 SAN DIEGO, CA 92123-4403 SAN DIEGO, CA 92123-4403 (561) 226-8210 (619) 805-5300 FEE AMOUNT FIRE TI Fire Alarm System $620.00 Total Fees: $620.00 Total Payments To Date: $620.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov HIGHLIGHTED SET Cut Sheets and CSFM Listing Sheets For: Thermo Fisher Scientific BLS2 Lab & Copy Center Tenant Improvements 5781 Van Allen Way Carlsbad, California 92008 Installer: tqCu Integrated 5erinty 3870 MURPHY CANYON ROAD SUITE 140 SAN DIEGO, CA. 92123 (800) 289-2647 LIC #977249 (C- 10, C-7) FPC20I8 -0392 5781 VAN ALLEN WAY THERMO FISHER - FIRE ALARM STROBES & HORNS IN BSL2 LAB & COPY CENTER 2121304400 12/412018 FPC20I 8-0392 Flreule®ALarms tncororae One Fire-Lite Place Northford, CT 06472 Phone: (203) 484-7161 FAX: (203) 484-7118 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 000000000 aoaaaooaaaaaaaoaa000aa000000000000a000aa 00000a00000000000000000000000000a000aa00 000a00000000000000a00aa0a000000000000000 0000000aa0000000000a00aua0000000a000000n oao00a00a00000000000000000000a000000a000 FCPS-24F FIRE Al AIlS FIELD CHAROERIPOWER SUPPLY FOR FIRE PRVIECTIORISIORALIRG SERVICE G aoaa no anna aaoaa a a aaaaaa on oaanooaaooanoan 000an1300130a00a0n00013000a0000000nn000a000 00000000000000000a0000000000000000000000 0000000000000000000000000000000000000000 000noaaanoanaanannaannnnaaaaaa000annaono a a a a a a a a a a a a a a a a a a an a a a a a a a a a a a a a a a a a a a a FCPS-24F/FCPS-24FE Field Charger/Power Supply Installation, Operation and Application Manual Document 50079 09/30/99 Revision: m- . Title PN 50079:E 09/30/99 System Overview Specifications To Transformer #2 To Transformer #1 N>N R' En En S + + + + I -4- + TB' Cut JP1 to disable battery charger or enable MPM-4 Voltmeter/ Ammeter To MPM-4 (Voltmeter/Ammeter) Connection C) E, 0 3140 )JP1 TB2M Battery fuse bA, 3AG slow blow R27 1 0000000 --;-'L) 5 2 9vu 1,'.-r 0 uIu -0oc0 <5,5 R175 I __ - —C. I — I — R76 JP2(D31 In+ (Control Input I In- fromFACP) I Out +/Trouble Contact lOut. I ,"WrI R176 Trouble Contact In+ (Control lnput2 R63 In - from FACP) r Auxiliary Output R134 Common TBS Note: Auxiliary Output supplies Specific Application Power, 45 mA Short Circuit Figure 1.1 FCPS Board Layout 8 Title PN 50079:E 09/30/99 ARM-4 Installation Installation Top 2.85" (7.3 CL 0 0 o 0 0 Backbox = 14.5" (36.8 cm) Depth = 3.562" (9.05 cm) U H S U Bottom 11.125"\ (2.868 cm) Figure 2.1 Backbox Mounting Dimensions Transformer Bottom Nut vU ----- k-i if MPM4 Meter - Ii Bracket Meter Assembly Cable Figure 2.2 MPM4 Installation Diagram Title PN 50079:E 09/30/99 11 External Device Power Battery Calculations SECTION 5 Battery Calculations 5.1 External Device Power The FCPS provides filtered 24 VDC power that may be used for operating Notification Appliance Circuits or other external devices. The power for operating external devices is limited. Use Table 5.1 (standby or nonalarm) and Table 5.2 (alarm) to determine if external loading is within the capabilities of the power supply. Refer to the device manufacturer's data sheets packaged with each device to find the standby and alarm current draws to use in the tables that follow. 5.2 Device Standby Current Draw The following table should include the total standby current draw of all devices on each active output, including End-of-Line relays when used for supervision. Device Type # of Devices Current (amps) Total Current (amps) Main PC Board without AC Fail Report Delay Enabled OR Main PC Board with AC Fail Report Delay Enabled (1 maximum) X (1 maximum) X 0.032 = 0.048 = MPM-4 [ I X 0.008 EOL Relays [ ] X = Smoke Detectors [ ] X = Smoke Detectors [ ] X = Annunciators { I . X = Auxiliary Devices [ I X = Auxiliary Devices [ I X = Auxiliary Devices [ ] X = Sum Column for Standby Load = amps Table 5.1 Load in Standby@24 VDC 5.2.1 Current Calculations 1. When Using the 6.0 amps Maximum Current Available: Five minutes under full load (6.0 amps current draw) requires 3.0 AH (Amp Hour) or a 7.0 AH capacity battery. The remaining 4.0 AH capacity must support the FCPS during its required standby time. Because of this, the standby current draw cannot exceed the figures listed below: For 24 hour standby time, the standby current draw cannot exceed 0.166 amps at 24 VDC (24 hours X 0.166A) = 3.984 AH For 60 hour standby time, the standby current draw cannot exceed 0.066 amps at 24 VDC (60 hours X 0.066A) = 3.96 AH To calculate Standby Current, subtract total standby load calculated above from 0.166 amps for 24 hours standby or 0.066 amps for 60 hours standby. This figure should not be less than zero. If the amount is less than zero, the required standby time will not be achieved Title PN 50079:E 09/30/99 23 Battery Calculations Device Standby Current Draw When Using Less than 6.0 amps Maximum Current, use the following tables to determine the proper battery size When Battery Amp-Hour Requirements are for Greater than 7.0 All, cut FCPS jumper JP 1 to disable onboard battery charger and use an external battery charger Device Type # of Devices Current (amps) Total Current (amps) Main PC Board without AC Fail Report Delay Enabled OR Main PC Board with AC Fail Report Delay Enabled (1 maximum) X (1 maximum) X 0.032 0.048 = MPM-4 [ J X 0.008 EOL Relays [ ] X = Smoke Detectors [ I X = Smoke Detectors [ I X = Annunciators [ ] X = Auxiliary Devices [ ] X = Auxiliary Devices [ ) X = Auxiliary Devices [ J X = Notification Appliances [ J X Notification Appliances [ ] X = Notification Appliances [ ] X = Sum Column for Standby Load = amps Table 5.2 Load in Alarm@24 VDC 5.2.2 Secondary Power Source Calculations Use the Total Standby and Alarm Load Currents calculated in Table 5.1 and Table 5.2 for the following battery calculation. Standby Load Current (amps) [I X Required Standby Time in Hours [ I (24 or 60 Hours) = Alarm Load Current (amps) [I X Required Alarm Time in Hours (i.e. 5 mm. = 0.084 hours)) [ I = Add Standby and Alarm Load for Required Ampere Hours = Multiply by the Derating Factor of 1.2 X Total Ampere Hours (AH) Required = Table 5.3 Secondary Power Source Calculations Notes. 1, Battery size is limited to 7.0,AH using the internal FCPS battery charger 2. For battery sizes greater than 7.0 AH, cut FCPS jumper JP I to disable the internal battery charger and use an external battery charger 24 Title PN 50079:E 09/30/99 D L :: 65 L ii DISCHARGE CHARACTERISTICS AT 25 C(77 F) I I I I I II I, 2 3 5 00 20 30 60 2 3 5 10 20 30 itii0 g 1 Discharge Time Chargeing Time (h) Cycle service life D2 0e2e60 200 400 600 600 1000 1200 Life (cycle) II 2 0. c_I 6 0 POER KINGDOM (eaIed Lead-Acid Batteries) Specifications Nominal Voltage 12V Rated Capacity 7Ah Dimensions Total Height 3.98 inches (101mm) Height 3.74 inches (95mm) Length 5.94 inches (151mm) Width 2.56 inches (65mm) Approximate Weight 4.52 lbs. (2.05kg) Characteristic Capacity 770F(250C) 20h rate 7.00Ah 10h rate 6.50Ah 5h rate 5.95Ah lh rate 4.20Ah 15 min rate 3.15Ah Internal Resistance Full Charged Battery 770F(25°C) 25m Capacity Affected by Temperature (20h rate) 1040F(400C) 102% 770F(25°C) 100% 32°F(0°C) 85% 50F(-150C) 65% Self-Discharge 68°F(200C) (Capacity after) 3 month storage 90% 6 month storage 80% 12 month storage 60% Max. Discharge Current_77°F(25°C) 105A(55) Terminal TI , T2 Charge (Constant Voltage,250C) Cycle I 14.5.44.9V(-24mV/0C) max. current: 2.1 A Float 13.6-13.8V(-18mVJ°C) Constant Current 1)iachar Characteristics (A.25C'i F.V/TIME 5min 10min 15min 30min 60min 3h 5h 10h 20h 9.60V 27.0 18.0 14.0 8.40 4.70 1.73 1.15 0.71 0.37 10.2V 25.7 17.1 13.4 8.06 4.55 1.70 1.13 0.70 0.36 10.5V 24.2 16.1 12.7 7.66 4.35 1. 65 1.10 0.68 0.35 Constant Current fliachare Characteristmes IVvatt.251'i F.V/TIMIE 5min 10min 15min 30min 60min 3h 5h 10h 20h 9.60V 301 203 160 94.2 54.4 20.6 13.8 8.52 4.43 10.2V 287 191 153 90.4 52. 7 20.2 13.6 8.40 4.33 10.5V 270 180 145 86.0 50.4 19.6 13.2 8.17 4.21 Indoor Selectable-) Output Strobes and Horn Strobes for Ceiling Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 30 candela Field-selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150, and 177 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and two volume selections Universal mounting plate for ceiling units Mounting plate shorting spring feature checks wiring continuity before device installation Electrically Compatible with legacy SpectrAlert and SpectrAlert Advance devices Compatible with MDL3 sync module Listed for ceiling mounting only Agency Listings SIGNAUNG (9 LISTED APPROVED S5512 FM approved except 7125-1653:0504 S4011 for ALERT models 7135-1653:0503 3057383 The System Sensor L-Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, wall and ceiling mounting options, System Sensor L-Series can meet virtually any application requirement. The entire L-Series product line of ceiling-mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature a plug-in design with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time- consuming ground faults. To further simplify installation, the L-Series utilizes a universal mounting plate so installers can mount them to a wide array of back boxes. With an onboard shorting spring, installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. L-Series Specifications General [-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double- gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync.Circuit°° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor [-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 115, 150, and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor [-Series Model listed to U[ 1971 and U[ 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync.Circuit model MD[3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize [-Series strobes at 1 Hz and horns at temporal three, Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3) 8.5 to 17.5V (12 V nominal) or 16.5 to 33 V (24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions (including lens) 6.8' diameter x 2.5' high (173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9' diameter x 3.4 high (175 mm diameter x 86 mm high) (SBBCRL, SBBCWL) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs P, 5, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. AVDS86800 UL Current Draw Data Candela 8-17.5 Volts DC i6-33 Volts) (bQ FWR (15) 87 (41) 60 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 UL Max. Current Draw (rnA RMS), 2-Wire Horn Strobe 8 175 Volts (16-33 Vits) DC Input 15cd 30cd 15cd 30cd (cd) 95cd 115cd 150cd 177cd ejemporal High) 103 167 71 90 (143) 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1KTemporal High 111 164 69 94 147 163 184 229 257 3.lKTemporal Low 103 163 54 88 143 155 185 212 252 3.1K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1K Non-Temporal Low 103 169 54 88 131 155 187 217 259 FWR Input 16-33 Volts 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1K Temporal High 108 135 179 200 225 255 289 3.lKTemporal Low 79 101 150 171 196 229 260 3.1K Non-Temporal High 108 135 179 200 225 255 289 3.1 K Non-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data 8-17.5 16-33 Volts Volts Switch Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 AVDS86BOO L-Series Dimensions 247 1.37 06.92 2.5O 0 Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box L-Series Ordering Information Ceiling Horn Strobes çRL) (2 Wire Horn Strobe Red) PC2WL 2-Wire, Horn Strobe, White Ceiling Strobes (SCR (Strobe Red SCWL Strobe, White SCWL-CLR-ALERT Strobe, White, ALERT Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box, White }I5 7,f 3B25 Ohio Avenue • St. Charles, IL 60174 @2017 System Sensor. Product specifications subject to change without notice. Visit systemseosor.com 5JJ5Qf Phone: 800-SENSOR2 • Fax: 630-377-6495 for current product information, including the latest version of this data sheet. AVDS86801 - 03/1 7 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (1-1653:0503) Page 1 of 2 CATEGORY: (7135 --AUDIBLE DEVICE) LISTEE: (ystem_Sensor)Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyevhoneywell.com DESIGN: System Sensor Indoor 2-wire and *4..wire Models: HWL, HRL, HGWL and HGRL Horns; CHWL and CHRL Chimes; P2RL, P2WL, P2GRL, P2GWL, P2RL-P, P2WL-P, P2RL-SP, P2WL-SP, *P4RL and *P4WL Wall Horn Strobes; (PC2RL PC2WL, *PC4RL and *PC4WL Ceiling Horn Strobes; CHSRL and CHSWL Wall Chime Strobes; CHSCRL and CHSCWL Ceiling Chime Strobes; Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-132, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WallTrim Rings: *TR2 and *TR2W CeilingTrim Rings: *TRC2 and *TRC2W Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: Revision 08-21-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 (Listing Expires)(J une 3O,2O19) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7135-1653:0503 Page 2 of 2 SBBCRL and SBBCWL MP120KL 120 VAC Adapter Mounting Plate Refer to listee's data sheet for detailed product description and operational considerations. RATING: 12 VDC regulated and 24 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as audible devices when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. Revision 08-21-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 (June 3O,2019) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION ..,.. OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM 6- ";; LISTING SERVICE LISTING No. (7125-1653:05) Page 1 of 2 CATEGORY: (25 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED) LISTEE: System Sensor3Unincorporated Div of Honeywell Intl lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyevhoneywell.com DESIGN: System Sensor Indoor 2-wire Models: SRL, SWL, SGRL, SGWL, SRL-P SWL-P, SRL-SP, SWL-CLR-ALERT and SWL-ALERT Wall Strobes; (SCRL) SCWL and SCWL-CLR-ALERT Ceiling Strobes. Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-132, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WallTrim Rings: TR2 and TR2W CeilingTrim Rings: TRC2 and TRC2W. Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: SBBCRL and SBBCWL Refer to listee's data sheet for detailed product description and operational considerations. 02-14-17 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 (June 30, 2019) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7125-1653:0504 Page 2 of 2 RATING: Regulated 12 VDC setting: 8-17.5 VDC Regulated 24 VDC/fwr setting: 16-33 VDC INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as two wire strobe units used for synchronous application when used with separately listed compatible fire alarm control units. Suitable for indoor use, vertical wall or horizontal ceiling mounted. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. 02-14-17 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 (yigExpfes (June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Indoor Selectable-) Output Strobes and Horn Strobes for Ceiling Applications SpectrA lertO Advance audible visible notification products are rich with features guaranteed to cut installation times and maximize profits. SPECTRQUert Features Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela Field-selectable candela settings on ceiling units: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and three volume selections Universal mounting plate for ceiling units Mounting plate shorting spring checks wiring continuity before device installation Electrically Compatible with legacy SpectrAlert devices Compatible with MDL sync module Listed for ceiling or wall mounting Agency Listings SIGNAUNG zzMEA LISTED APPROVED approved 7125-1653:186 indoor strobes) 7125-1653:188 (horn strobes, S4011 (chimes, horn strobes, horns) 3023572 M8A452-05-E chime strobes) S5512 (strobes) 7135-1653: 189 (horns, chimes) The SpectrAlert Advance series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE-printed devices, SpectrAlert Advance can meet virtually any application requirement. Like the entire SpectrAlert Advance product line, ceiling-mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, SpectrAlert Advance utilizes a universal mounting plate with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with three volume selections. SpectrAlert Advance Specifications General SpectrAlert Advance strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double- gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync.Circuit°° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync-Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync.Circuit model MDL listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions (including lens) 6.8" diameter x 2.5" high (173 mm diameter x 64 mm high) Ceiling-Mount Back Box Skirt Dimensions (BBSC-2, BBSCW-2) 7.1"diameter x 22" high (180 mm diameter x 57 mm high) Ceiling-Mount Trim Ring Dimensions (sold as a 5 pack) (TRC-HS, 6.9-diameter x 0.35" high (175 mm diameter x 9 m high) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. F, 5, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDSOO5O1 UL Current Draw Data ',,UL,--Max. Strobe'CUrrObt Draw (tiikR 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Standard Candela Range 15 123 128 66 71 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High 135 NA NA 228 207 Candela Range 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, Standard Candela Range (15-115 cd) 8-17.5 Volts C16-33 Volts) FD C!npJ 15 15175 15 15175 30 (75) 95 110 115 (Temporal High) 137 147 79 90 107 (17 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 DC Input 16-33 Volts 135 150 177 185 FWR Input 16-33 Volts 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 236 254 291 295 Non-Temporal Low 214 229 256 262 Horn Strobe Tones and Sound Output Data 8-17.5 16-33 24-Volt Nominal Switch Volts Volts Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 75 75 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 75 75 81 81 88 85 96 92 Settings 7, 8, and 9 are not available on 2-wire horn strobes. AV0500501 (Ceiling-mount horn strobes) .8" a. SpectrAlert Advance Dimensions ,-7.1" 2.25'1 Dia. I________ 2 Q O Ic (çeijjngbaci_box skirt SpectrAlert Advance Ordering Information Ceiling Horn Strobes PC2R*) (2-Wire Horn Strobe, Standard Cd, Red) PC2RH 2-Wire Horn Strobe, High Cd, Red PC2W*t 2-Wire Horn Strobe, Standard Cd, White Model Description Ceiling Strobes (SCR) (Strobe, Standard cd, Red) SCRH Strobe, High Cd, Red SCW* Strobe, Standard Cd, White PC2WH* 2-Wire Horn Strobe, High Cd, White SCWH Strobe, High Cd, White PC4R 4-Wire Horn Strobe, Standard Cd, Red Accessories PC4RH 4-Wire Horn Strobe, High Cd, Red PO4W 4-Wire Horn Strobe, Standard Cd, White (13BSC-2 Back Box Skirt, Ceiling, Red) Back Box Skirt, Ceiling, White TRC-HS Trim Ring Ceiling, Redj TRCW- Trim Ring, Ceiling, White HS Notes: * Add "-P' to model number for plain housing (no "FIRE" marking on Cover), e.g., P2R-P. f Add '-SP" to model number for "FUEGO" marking on cover, e.g., P2R-SP. I: "Standard cd' refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. 'High Cd" refers to strobes that include 135, 150, 177, and 185 candela settings. 3825 Ohio Avenue • St. Charles, IL 60174 @2012 System sensor. Product spoof cat one subject to change without notice. Visit systemsensor.com SENSOR' Phone: 800-SENSOR2 • Fax: 630-377-6495 AVDSOO5OS •3/12 for current product information, including the latent version of this data sheet CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM - LISTING SERVICE LISTING No. (7125-1653:0188J Page 1 of 1 CATEGORY: (7125 ---FIRE ALARM DEVICES FOR THE HEARING IMPAIRED) LISTEE: (System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. CharIesIL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.KireyevhoneywelI.com DESIGN: Models CHSR and CHSW Chime/Strobes. Models P2R, P2W, P2RH and P2WH Horn/Strobes two-wire type, rectangular enclosure. ModeIs(Pë) PC2W, PC2RH and PC2WH Horn/Strobes two-wire type, round enclosure Models P4R, P4W, P4RH and P4WH Horn/Strobes four-wire type, rectangular enclosure. Models PC4R, PC4W, PC4RH and PC4WH Horn/Strobes* four-wire type, round enclosure. All models are intended for indoor use only unless other wise indicated. Models may be followed by the suffix "K" indicating indoor or outdoor use, or may be followed by suffix "P' for plain housing with no lettering. "K" suffix models are suitable for outdoor applications at temperatures from -40°F to +151°F (-40°C to +66°C) and are rated NEMA 4X when used with the System Sensor weather proof back boxes models SA-WBB (Wall), SA-WBBW (Wall), SA-WBBC (Ceiling) and *SA..WBBCW (Ceiling). Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Standard Horn/Strobes and Chime/Strobes 8 - 17.5 or 16-33 VDC/FWR Hi CD Horn/Strobes 16-33 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as *horn/strobes or chime/strobes suitable for signaling appliances and equipment for the hearing impaired applications when used with separately listed compatible fire alarm control units. Horn/strobes with -K suffix are suitable for indoor or outdoor use, ceiling or wall mount. Chime section is suitable for private mode and indoor use only. Horn/Strobes or chime/strobes* can generate the distinctive three-pulse audible Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2010 Edition. Refer to listee's Installation Instruction Manual for details. *Corrected 12-15-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 ExpireJ (June 30, 2019) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division SECTION2 FIRE ALARM CABLE I PART NUMBER AWG IC0N0b0RI SHIELDED! OVERALL I UNSHIELDED DIAMETER I CONDUCTOR COLOR COLOR VOLTAGE I RATING WEIGHT I (Ibs)flJnit MARKINGS TEMP purl I 14 AWG I WHITE I 300v I 50.0 ADT 494479 2/C 60°C 500 BLACKJ RED, LBS 14 AWG 2/C lB AWG REEL 18AWG TYPE FPLR/ CL3R UOHT BLUE / (UL) YELLOW BLACK, RED RED 20.0 2C 14AWG (UL) LBS FPLR WHITE 20,0 AOl 494478 75O LBS 2C14AWG TYPE FPLR/ CL3R (UL) (CSA) BLACK, RED, RED 35.0 FPLRJCL3R BROWN, BLUE LBS 14 AWG (UL) BLACK, RED WHITE 33.0 AOl 494480 LBS 2012AW5 TYPE FPLR/ CL3R (UL) (GSA) !IJ 1 2.12 DON'T SEE IT? CALL 1-888-4238947 ORDERS: PHONE 1-888-423-8947, FAX 847-797-3853 V'\ I 2.1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION ..... OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (7161-2075:0100) Page 1 of 1 CATEGORY: (T161 -- CABLES-FIRE PROTECTIVE SIGNALING) LISTEE: (Paige Electric Companyjj9)Springfield Road, Union, NJ 07083 Contact: Cindy Regner (908) 687-7810 Fax (908) 687-8860 Email: cregnerpaigeelectric.com DESIGN: Types FPL, FPLP and [power limited fire protective signaling cables. Insulation - PVC compound AlphaGary Smokeguard 4010, Synergistics 1349-1028 FRD, 1360-1021-PID, PP, HDPE or LDPE. Shields - (Optional) All metal or Aluminum Polyester tape. Braid - (Optional) All metal. Jacket - PVC compound AlphaGary Smokeguard 11 6920, Gitto Global GA-8705-03, AlphaGary GW2038, Synergistics 1690-1060, 1604-1007 FR, 1100-1092 FRD, JAP6IA or 1410-1011 FRD, Solef 31008-0003. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, NEC Article 760, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, Type FPL, FPLP or FPLR, rating and UL label. APPROVAL: Listed as power-limited fire protective signaling cables. NOTE: Formally 7161-1677:100 XLF: 7161-1509:0100 mt 09-09-11 mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 e3O,2O19) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division