HomeMy WebLinkAbout2842 WHIPTAIL LP; ; FPC2018-0348; PermitPERT REPORT (City 0f Carlsbad I AR~) Print Date: 10/05/2022 Permit No: FPC2018-0348 Job Address: 2842 WHIPTAIL LOOP, CARLSBAD, CA 92010 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2091202200 Track #: Applied: 10/22/2018 Valuation: $3,098,646.74 Lot #: Issued: 12/28/2018 Occupancy Group: Project #: DEV2017-0109 Finaled Close Out: 09/26/2019 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check #: INSPECTOR: Fieri, Dominic Plan Check #: Salcedo, Felix Wong, Cindy Project Title: REYNOLDS LOT 20 Description: WHIPTAIL LOT 20 -FIRE SPRINKLERS FOR SHELL (354 HEADS) Applicant: FPContractor: EPIC FIRE PROTECTION INC EPIC FIRE PROTECTION INC ADAM BOISVERT 765 TURTLE POINT WAY 765 TURTLE POINT WAY SAN MARCOS, CA 92069-8126 SAN MARCOS, CA 92069-8126 (760) 310-6122 (760) 310-6122 FEE AMOUNT FIRE NFPA 13 System > 100 heads (includes 1 riser) $858.00 Total Fees: $858.00 Total Payments To Date: $858.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov Contractor Information - EPIC FIRE PROTECTION, INC 765 TURTLE POINT WAY SAN MARCOS, CA 92069 calculated by ADAM BOISVERT telephone 760-310-6122 fax 760-798-0556 email EPICFIRE@COX.NET Snrinklic in Pømrt Sprinklers .......... No. Mfgr Mod SIN# Size K 9 VICTAULIC EC V3428 17/32- 8.0 I GLOBE SSP GL5601 1/2 5.6 @980(r Hydraulics Summary Sheet Project Information PPC20 1&. O4 Calculation Date: 9/27/2018 10:40:31 AM REYNOLDS LOT 20 MEZZANINE system ID drawing ref 2 OF 2 building NEW 2842 WHIPTAIL LOOP construction Ill-B CARLSBAD, CA 92010 occupancy B, F-i S-i contract # authority CARLSBAD FD Hydraulics Criteria density .10 GPM/ft' system type WET design std NFPA 13, 2016 remote area 1500 ft' hazard LIGHT spr coverage 400 ft' sprs flowing 10 figure calc'd volume 1,710.7 gal curve ,..- Flow Test static pressure 108.90 psi residual pressure 81.00 psi quantity flowing 8,000.0 GPM elevation from if 420.00 ft date & time of flow test 8-20-18 location of flow test site 160 )ply I Demand Graph 108.72 psi available at Sprinkler Demand of 79.35 psi with System Flow of 519.3 GPM —I Marain: +27.0% k- 120 100 to CL 40 20 0-- 075 150 225 300 © Copyright 2013 Sigma Development Group, Inc. N185 375 450 525 600 Water Flow (GPM) Page 1 of 14 Dboanlffydiaulks Supply Analysis REYNOLDS LOT 20 MEZZANINE Sprinkler Flow: 419.3 GPM Additional Flows: 100.0 GPM Hose Flow at Zero: None Total System Flow: 519.3 GPM Maximum velocity in pipe 210-215 is 19.8 ft/sec Nodes Analysis Minimum Node Actual Node Elev Device KFactor Flow Pressure Discharge Notes ft GPM psi GPM 236 446.9 Sprinkler 5.60 17.66 25.08 28.04 238 446.9 Sprinkler 8.00 40.00 25.00 40.00 237 446.9 Sprinkler 8.00 40.00 25.11 40.08 234 446.9 Sprinkler 8.00 40.00 25.74 40.58 232 446.9 Sprinkler 8.00 40.00 27.74 42.14 230 446.9 Sprinkler 8.00 40.00 30.53 44.20 239 446.9 Sprinkler 8.00 40.00 32.17 45.38 235 446.9 Sprinkler 8.00 40.00 32.37 45.51 233 446.9 Sprinkler 8.00 40.00 33.28 46.15 231 446.9 Sprinkler 8.00 40.00 34.79 47.19 2 436.1 Hose Flow 1 71.17 100.0 0 Copyright 2013 Sigma Development Group, Inc. Page 2 of 14 €oo DashlxianfHydrauflcs From Elevi ft Elev2 To ft Pipe Information Pipe ID I Flows I I I Length I Added I Inside GPM I Diameter Fittings I Fitting Type Total I ITotal REYNOLDS LOT 20 MEZZANINE ft C Value J Total (Pt) psil ion Loss Elev (Pe) psi Notes ft psi/ft Frict psi 228 450.88 1"Eddylhead Len 4.01 = 120 I Pt 238) 25.000 1.0830 T Ftg 5.8 -f Pe -1.732 238 446.88 AO 40.0 iEii1 0.401631 Pf 3.952 227 450.88 2" Eddy Flow 2.2030 0 Len 9.5 120 0.012 } Pt 228) 27.219 Pe 0.000 pf0.120 228 450.88 BN 40.0 Total 9.5 Total Pressure at Node 227) 27.339 psi 229 450.88 1" Eddy Thead 1.0830 T Len 4.0 Ftg 5.8 C= 120 0.50718 Pt 239) 32.173 Pe -1.732 Pt 4.991 239 446.88 AO 45.4 Total 9.8 225 450.88 2" Eddy Flow 2 . 2030 0 Len 14.0 Ftg 0.0 C = 120 0.01597 Pt 229) 35.431 Pe 0.000 Pt 0.224 229 450.88 BN 45,4 Total 14-0 1 Total Pressure at Node 225) 35.655 psi 227 450.88 1"EddyThead 1 ' 0830 1 Len 4.0 Ftg 5.8 c = 120 0.40318 Pt 237) 25.105 Pe -1.732 Pt 3.967 237 446.88 AO 40.1 Total 9.8 226 450.88 2" Eddy Flow 40.0 2.2030 0 Len 4.5 Ftg 0.0 C = 120 0.04568 Pt 227) 27.339 Pe 0.000 Pt 0.206 227 450.88 BN 80.1 Total 4.5 Total Pressure at Node 226) 27.545 psi 12.0 Len f ,E I Ftg 8.2 _-!9_ Pt 236) 25.077 1.0830 T Pe -1.732 226 450.88 1"Eddy Thead 20.2 0.20821 Pt 4.201 236 446.88 AO 28.0 Total 224 450.88 2" Eddy Flow 80.1 2.2030 0 ken 6.51 Ftg 0.0 c = 120 0.07961 Pt 226) 27.545 Pe 0.000 Pt 0.517 226 450.88 BN 108.1 IiT 611 Total Pressure at Node 224) 28.062 psi 225 450.88 Eddy mead 1.0830 T Len 4.0 Ftg 5.8 C = 120 0.51003 Pt 235) 32.369 Pe -1.732 Pt 5.019 235 446.88 AO 45.5 Total 9.8 223 450.88 Eddy Flow 45.4 2.2030 0 Len 18.0 Ftg 0.0 C = 120 0.05774 Pt 225) 35.655 Pe 0.000 Pt 1.039 225 450.88 BN 90.9 Total 18.0 Total Pressure at Node 223) 36.694 psi 0 Copyright 2013 Sigma Development Group, Inc. Page 3 of 14 Joo' Pipe Information Dashboa,dHydraulks REYNOLDS LOT 20 MEZZANINE From Elevi Pipe ID Flows T Inside [Length ft I C Value ITotal (Pt) )SI ft Added GPM I Diameter Fittings Fitting ft I 1 Elev (Pe) Psi Notes To EI ev 2 Type I in Friction Lossl jTotal Total ft psi/ft 1F (Pf) psi 224 450.88 1"EddyThead 1.0830 T Len 4.0 Ftg 5.8 C= 120 0.41255 Pt 234) 25.736 Pe -1.732 Pf 4.060 234 446.88 AO 40.6 Total 9.8 222 450.88 2" Eddy Flow 108.1 2.2030 0 Len 16.0 Ftg 0.0 C= 120 0.14355 Pt 224) 28.062 Pe 0.000 Pf 2.297 224 450.88 BN 148.7 Total 16.0 Total Pressure at Node 222) 30.359 psi 223 450.88 1"EddyThead 1.0830 1 Len 4.0 Ftg 5.8 C= 120 0.52327 Pt 233) 33.278 Pe -1.732 Pt 5.149 233 446.88 AO 46.1 Total 9.8 221 450.88 2" Eddy Flow 90.9 2.2030 0 Len 14.0 Ftg 0.0 C = 120 0.12341 Pt 223) 36.694 Pe 0.000 Pt 1.728 223 450.88 BN 137.0 Total 14.0 Total Pressure at Node 221) 38.422 psi 222 450.88 1" Eddy Thead 1.0830 T Len 4.0 Ftg 5.8 c = 120 0.44219 Pt 232) 27.741 Pe -1.732 Pt 4.351 232 446.88 AO 42.1 Total 9.8 220 450.88 2" Eddy Flow 148.7 2.2030 0 Len 14.0 Ftg 0.0 C = 120 0.22774 Pt 222) 30.359 Pe 0.000 Pt 3.188 222 450.88 BN 190.8 Total 14.0 Total Pressure at Node 220) 33.548 psi 221 450.88 1"EddyThead 1.0830 T Len 4.0 Ftg 5.8 C= 120 0.54522 Pt 231) 34.790 Pe -1.732 Pt 5.365 231 446.88 AO 47.2 Total 9.8 216 450.88 2" Eddy Flow 137.0 2.2030 110 Len 18.0 Ftg 13.6 C = 120 0.21334 Pt 221) 38.422 Pe 0.000 Pt 6.750 221 450.88 BN 184.2 Total 31.6 211 449.38 2" Eddy Flow 2.2030 TIO Len 1.5 Ftg 13.6 C= 120 0.21334 Pt 216) 45.172 Pe 0.650 Pt 3.230 216 450.88 NR 184.2 15.1 Total Total Pressure at Node 211) 49.051 psi 220 450.88 1"EddyThead 1.0830 1 Len 4.0J C= 120 0.48312 Pt 230) 30.527 Pe -1.732 Pt 4.754 230 446.88 AO 44.2 Total 9.81 © Copyright 2013 Sigma Development Group, Inc. Page 4 of 14 4 OO- Da Pipe Information REYNOLDS LOT 20 MEZZANINE shboard Hydraulics From Elevi ft T Pipe ID Flows Added GPM Inside Diameter in Fittings Length ft IFitting C Value Total (Pt) psi J Notes ft Elev(Pe) psi] Fnct(Pf) psi To Elev2 1 Type Friction LO$J psilft Total jTotal 1 215 450.88 2" Eddy Flow 190.8 2.2030 TIO ILen 18.01 I Ftg 13.6 c = 120 I- 0.33482 Pt 220) 33.548 Pe 0.000 Pt 10.593 220 450.88 BN 235.0 Totatr3.6 210 449.38 2" Eddy Flow 2.2030 110 ILen 1.51 Ftg 13.6 C=120 0.33482 Pt 215) 44.141 Pe 0.650 Pt 5.069 215 450.88 NR 235.0 fTotal 15.1 Total Pressure at Node 210) 49.859 psi 25 466.38 4" Eddy Flow 4.3100 Len 25.0 Ftg 0.0 C = 120 0.00156 Pt 200) 54.177 Pe 0.000 Pt 0.039 200 466.38 CMI 75.6 Total 25.0 26 466.38 4" Eddy Flow -38.1 4.3100 0 Len 12.0 Ftg 0.0 C= 120 0.00043 Pt 25) 54.216 Pe 0.000 Pf 0.005 25 466.38 CM1 37.5 66 467.21 2" Eddy Flow 2.2030 1 Len 0.8 Ftg 13.6 C = 120 0.01122 Pt 26) 54.221 Pe -0.359 Pt 0.162 26 466.38 RN 37.5 Total 14.5 86 467.21 2" Eddy Flow 2.2030 1ff Len 77.0 Ftg 27.3 C = 120 0.01122 Pt 66) 54.024 Pe 0.000 Pf 1.170 66 467.21 BL 37.5 Total 104.3 46 466.38 2" Eddy Flow 2.2030 1 Len 0.8 Ftg 13.6 C = 120 0.01122 Pt 86) 55.193 Pe 0.359 Pt 0.162 86 467.21 RN 37.5 Total 14.5 45 466.38 4" Eddy Flow 4.3100 0 Len 12.0 Ftg 0.0 C = 120 0.00043 Pt 46) 55.715 Pe 0.000 Pt 0.005 46 466.38 CM2 37.5 Total 12.0 44 466.38 4" Eddy Flow 38.1 4.3100 0 Len 10.0 Ftg 0.0 C = 120 0.00156 Pt 45) 55.720 Pe 0.000 Pt 0.016 45 466.38 CM2 75.6 Total 10.0 43 466.38 4" Eddy Flow 36.9 4.3100 0 Len 10.0 Ftg 0.0 C = 120 0.00326 Pt 44) 55.736 Pe 0.000 Pt 0.033 44 466.38 CM2 112.5 Total 10.0 42 466.38 4" Eddy Flow 34.3 4.3100 0 Len 10.0 Ftg 0.0 C = 120 0.00534 Pt 43) 55.768 Pe 0.000 Pt 0.053 43 466.38 CM2 146.8 _ Total 10.0 © Copyright 2013 Sigma Development Group, Inc. Page 5 of 14 Da ,i8OO'" Pipe Information REYNOLDS LOT 20 MEZZANINE From Elevi Pipe ID Flows I I Inside Length ft C Value 1 Total (Pt) psi Fitting ft I I Elev (Pe) psi ft Added GPM I Diameter Fittings I Notes To EIev2 Type in '' Friction Loss Total Total ft [ psi/ft ] Frict (Pt) psi 41 466.38 4" Eddy Flow 32.6 4.3100 0 Len 10.0 Ftg 0.0 C = 120 0.00773Pt Pt 42) 55.822 Pe 0.000 0.077 42 466.38 CM2 179.4 1Total 0.0 40 466.38 4" Eddy Flow 25.6 4.3100 0 1 Len 10.0 Ftg 0.0 C = 120 0.00989 Pt 41) 55.899 Pe 0.000 Pf 0.099 41 466.38 CM2 205.0 39 466.38 4" Eddy Flow 9 4.3100 0 Len 10.0 Ftg 0.0 C = 120 0.00928 Pt 40) 55.998 Pe 0.000 Pf 0.093 40 466.38 CM2 198.0 Total 10.0 38 466.38 4" Eddy Flow -7.7 4.3100 0 Len 10.0 Ftg 0.0 C = 120 0.00863 Pt 39) 56.091 Pe 0.000 Pt 0.086 39 466.38 CM2 190.3 Total 10.0 37 466.38 4" Eddy Flow -8.9 4.3100 0 Len 10.0 Ftg 0.0 C = 120 0.00790 Pt 38) 56.177 Pe 0.000 Pt 0.079 38 466.38 CM2 181.4 Total 10.0 36 466.38 4" Eddy Flow -10.4 4.3100 0 Len 10.0 Ftg 0.0 C = 120 0.00708 Pt 37) 56.256 Pe 0.000 Pt 0.071 37 466.38 CM2 171.0 Total 10.0 35 466.38 4" Eddy Flow -12.2 4.3100 0 Len 10.0 Ftg 0.0 C = 120 0.00617 Pt 36) 56.327 Pe 0.000 Pt 0.062 36 466.38 CM2 158.8 Total 10.0 34 466.38 4" Eddy Flow -14.3 4.3100 0 Len 10.0 Ftg 0.0 C = 120 0.00518 Pt 35) 56.388 Pe 0.000 Pt 0.052 35 466.38 CM2 144.5 Total 10.0 33 466.38 4" Eddy Flow -16.7 4.3100 0 Len 10.0 Ftg 0.0 C 120 Pt 34) 56.440 Pe 0.000 Pf 0.041 34 466.38 CM2 127.8 Total 10.0 32 466.38 4" Eddy Flow -19.2 4.3100 0 Len 10.0 Ftg 0.0 C = 120 0.00306 Pt 33) 56.481 Pe 0.000 Pt 0.031 33 466.38 CM2 108.6 Total 10.0 31 466.38 4" Eddy Flow -22.1 4.3100 0 Len 10.0 Ftg 0.0 C = 120 0.00201 Pt 32) 56.512 Pe 0.000 Pt 0.020 32 466.38 CM2 86.5 Total 10.0 30 466.38 4" Eddy Flow -23.4 4.3100 0 Len 10.0 Ftg 0.0 C = 120 0.00112 Pt 31) 56.532 Pe 0.000 Pt 0.011 31 466.38 CM2 63.2 Total 10.0 0 Copyright 2013 Sigma Development Group, Inc. Page 6 of 14 8OO Da Pipe Information REYNOLDS LOT 20 MEZZANINE From Elevi Pipe ID Flows Inside Length ft I C Value T Total (Pt) psi Fitting ft Elev (Pe) psi ft Added GPM Diameter Fittings Notes To Elev2 Type In riction Lost Total Total ft psi/ft Frict (PQ psi 29 466.38 4" Eddy Flow -22.9 4.3100 0 Len 8.01 Ftg 0.0 C = 120 Pt 30) 56.543 Pe 0.000 0.004 30 466.38 CM2 40.2 h-1 0.00049JPf Total 8.0 69 467.21 2" Eddy Flow -19.0 2.2030 T Len 0.8 Ftg 13.6 c = 120 0.00393 Pt 29) 56.547 Pe -0.359 P1 0.057 29 466.38 RN 21.3 Total 14.5 89 467.21 2" Eddy Flow 2.2030 T Len 66.0 Ftg 13.6 c = 120 0.00393 Pt 69) 56.244 Pe 0.000 Pt 0.313 69 467.21 BL 21.3 Total 79.6 90 467.21 3" Eddy Flow 19.0 3.3340 T Len 8.0 Ftg 22.5 c = 120 0.00170 Pt 89) 56.557 Pe 0.000 Pt 0.052 89 46721 BL 40.2 Total Pressure at Node 90) 56.609 psi 28 466.38 4" Eddy Flow 4.3100 0 Len 8.0 Ftg 0.0 = 120 0.00012 Pt 29) 56.547 Pe 0.000 Pf 0.001 29 466.38 CM2 19.0 Total 8.0 68 467.21 2" Eddy Flow 2.2030 1 Len 0.8 Ftg 13.6 = 120 0.00318 Pt 28) 56.548 Pe -0.359 Pt 0.046 -1 28 466.38 RN 19.0 Total 14.5 88 467.21 2" Eddy Flow 2.2030 1 Len 66.0 Ftg 13.6 C = 120 0.00318 Pt 68) 56.234 Pe 0.000 Pt 0.254 68 467.21 BL 19.0 Total 79.6 89 467.21 2" Eddy Flow 2.2030 1 Len 8.0 Ftg 13.6 c = 120 0.00318 Pt 88) 56.488 Pe 0.000 Pt 0.069 88 467.21 BL 19.0 Total 21.6 Total Pressure at Node 89) 56.557 psi 70 467.21 2" Eddy Flow 2.2030 T Len 0.8 Ftg 13.6 = 120 0.00452 Pt 30) 56.543 Pe -0.359 Pt 0.065 30 466.38 RN 22.9 Total 14.5 90 467.21 2" Eddy Flow 2.2030 T Len 66.0 Ftg 13.6 C = 120 0.00452 Pt 70) 56.249 Pe 0.000 Pt 0.360 70 467.21 BL 22.9 Total 79.6 50 467.21 3" Eddy Flow 40.2 3.3340 1 Len 71.5 Ftg 22.5 C= 120 0.00391 Pt 90) 56.609 Pe 0.000 Pt 0.368 90 467.21 BL 63.2 Total 94.0 0 Copyright 2013 Sigma Development Group, Inc. Page 7 of 14 8O Pipe Information Da REYNOLDS LOT 20 MEZZANINE From Elevi ft Pipe ID Flows Added GPM Inside Diameter In Fittings Length ft I C Value [Total (Pt) psi Notes Fitting ft Elev (Pe) psi To Elev2 Type Friction Loss psi/ft Total Total ft j Fnct (PQ psi 10 466.38 3" Eddy Flow 3.3340 1 Len 0.8 Ftg 22.5 c = 120 0.00391 Pt 50) 56.977 Pe 0.359 Pt 0.091 50 467.21 RN 63.2 Total 23.3 11 466.38 4" Eddy Flow 4.3100 0 Len 10.0 Ftg 0.0 C = 120 0.00112 Pt 10) 57.427 Pe 0.000 Pf 0.011 10 466.38 CM1 63.2 Total 10.0 Total Pressure at Node 11) 57.439 psi 65 467.21 2" Eddy Flow 2.2030 1 Len 0.8 Ftg 13.6 C = 120 0.01155 Pt 25) 54.216 Pe -0.359 Pt 0.167 25 466.38 RN 38.1 85 467.21 2" Eddy Flow 2.2030 111 Len 74.0 Ftg 27.3 C = 120 0.01155 Pt 65) 54.023 Pe 0.000 Pf 1.170 65 467.21 BL 38.1 Total 101.31 45 466.38 2" Eddy Flow 2.2030 T Len 0.8 Ftg 13.6 C = 120 0.01155 Pt 85) 55.193 Pe 0.359 Pt 0.167 85 467.21 RN 38.1 Total 14.5 Total Pressure at Node 45) 55.720 psi 24 466.38 4" Eddy Flow 4.3100 0 Len 5.5 Ftg 0.0 C = 120 0.02574 Pt 200) 54.177 Pe 0.000 Pt 0.142 200 466.38 CM1 343.7 Total 5.5 64 467.21 2" Eddy Flow -306.8 2.2030 1 Len 0.8 Ftg 13.6 C = 120 0.01088 Pt 24) 54.318 Pe -0.359 Pt 0.157 24 466.38 RN 36.9 Total 14.5 84 467.21 2" Eddy Flow 2.2030 TIT Len 74.0 Ftg 27.3 C = 120 0.01088 Pt 64) 54.116 Pe 0.000 Pt 1.102 64 467.21 BL 36.9 Total 101.3 44 466.38 2" Eddy Flow 22030 1 Len 0.8 Ftg 13.6 C= 120 0.01088 Pt 84) 55.219 Pe 0.359 Pt 0.157 84 467.21 RN 36.9 Total 14.5 Total Pressure at Node 44) 55.735 psi 23 466.38 4" Eddy Flow 4.3100 0 Len 10.0 Ftg 0.0 C = 120 0.02087 Pt 24) 54.318 Pe 0.000 Pt 0.209 24 466.38 CM1 306.8 Total 10.0 63 467.21 2" Eddy Flow -272.5 2.2030 T Len 0.8 Ftg 13.6 C = 120 0.00953 Pt 23) 54.527 Pe -0.359 Pt 0.138 23 466.38 RN 34.3 Total 14.5 0 Copyright 2013 Sigma Development Group, Inc. Page 8 of 14 Aft oo Pipe Information REYNOLDS LOT 20 MEZZANINE From Elevi Pipe ID Flows I I Inside Length ft [ C Value ITotal (Pt) psi Fitting ft Elev (Pe) psi ft Added GPM I Diameter Fittings I Notes Friction Loss To EIev2 Type I in Total Total ft [ psi/ft Frict (PQ psi 83 467.21 2" Eddy Flow 2.2030 TIT Len 74.0 Ftg 27.3 c = 120 0.00953 Pt 63) 54.305 Pe 0.000 Pt 0.965 63 467.21 BL 34.3 Total 101.3 43 466.38 2" Eddy Flow 2.2030 1 Len 0.8 Ftg 13.6 C = 120 0 .00953 Pt 83) 55.271 Pe 0.359 Pt 0.138 83 467.21 RN Total 14.5 Total Pressure at Node 43) 55.768 psi 22 466.38 4" Eddy Flow 4.3100 0 Len 10.0 Ftg 0.0 C = 120 0.01675 Pt 23) 54.527 Pe 0.000 Pt 0.168 23 466.38 CMI 272.5 Total 10.0 62 467.21 2" Eddy Flow -239.9 2.2030 1 Len 0.8 Ftg 13.6 C = 120 0.00866 Pt 22) 54.695 Pe -0.359 Pt 0.125 22 466.38 RN 32.6 Total 14.5 82 467.21 2" Eddy Flow 2.2030 TIT Len 74.0 Ftg 27.3 C = 120 0.00866 Pt 62) 54.460 Pe 0.000 Pt 0.877 62 467.21 BL 32.6 Total 101.3 42 466.38 2" Eddy Flow 2.2030 1 Len 0.8 Ftg 13.6 C = 120 Pt 82) 55.337 Pe 0.359 Pt 0.125 82 467.21 RN 32.6 0.00866 Total 145 Total Pressure at Node 42) 55.821 psi 21 466.38 4" Eddy Flow 4.3100 0 Len 10.0 Ftg 0.0 C = 120 0.01324 Pt 22) 54.694 Pe 0.000 Pt 0.132 22 466.38 CM1 239.9 Total 10.0 61 467.21 2" Eddy Flow -214.3 2.2030 T Len 0.8 Ftg 13.6 c = 120 0.00553 Pt 21) 54.827 Pe -0.359 Pt 0.080 21 466.38 RN 25.6 Total 14.5 81 467.21 2" Eddy Flow 2.2030 TIT Len 137.5 Ftg 27.3 C = 120 000553 Pt 61) 54.547 Pe 0.000 Pt 0.912 61 467.21 BL 25.6 Total 164.8 41 466.38 2" Eddy Flow 2.2030 1 Len 0.8 Ftg 13.6 C = 120 0.00553 Pt 81) 55.459 Pe 0.359 Pt 0.080 81 467.21 RN 25.6 Total 14.5 Total Pressure at Node 41) 55.899 psi 80 467.21 2" Eddy Flow 2.2030 T Len 0.8 Ftg 136 C = 120 Pt 40) 55.998 Pe -0.359 Pt 0.007 40 466.38 RN 6.9 Total 140.00049 0 Copyright 2013 Sigma Development Group, Inc. Page 9 of 14 pail i~ Pipe Information REYNOLDS LOT 20 MEZZANINE From Elevi ft Pipe ID Flows Added GPM Inside Diameter in Fittings Length ftT I C Value ] I Total (Pt) psij Notes Fitting ft I Elev (Pe) psi i To Elev2 Type Friction Loss psi/ft ] Total Total ftl Frict(PQ psi 60 467.21 2" Eddy Flow 2.2030 TIT Len 137.5 Ftg 27.3 C = 120 0.00049 Pt 80) 55.645 Pe 0.000 pf 0.081 80 467.21 BL 6.9 Total 164.8 20 466.38 2" Eddy Flow 2.2030 T Len 0.8 Ftg 13.6 c = 120 0.00049 Pt 60) 55.727 Pe 0.359 Pt 0.007 60 467.21 RN 6.9 Total 14.5 Total Pressure at Node 20) 56.093 psi 79 467.21 2" Eddy Flow 2.2030 1 Len 0.8 Ftg 13.6 C -120 0.00060 Pt 39) 56.091 Pe -0.359 Pt 0.009 39 466.38 RN 7.7 Total 14.5 59 467.21 2" Eddy Flow 2.2030 111 Len 137.5 Ftg 27.3 C = 120 0.00060 Pt 79) 55.740 Pe 0.000 Pt 0.099 79 467.21 BL 7.7 19 466.38 2" Eddy Flow 2.2030 1 Len 0.8 Ftg 13.6 C = 120 0.00060 Pt 59) 55.839 Pe 0.359 Pt 0.009 59 467.21 RN 7.7 Total 14.5 Total Pressure at Node 19) 56.207 psi 78 467.21 2" Eddy Flow 2.2030 T Len 0.8 Ftg 13.6 C = 120 0.00078 Pt 38) 56.177 Pe -0.359 Pt 0.011 38 466.38 RN 8.9 Total 14.5 58 467.21 2" Eddy Flow 2.2030 lIT Len 137.5 Ftg 27.3 C = 120 0.00078 Pt 78) 55.829 Pe 0.000 Pt 0.129 78 467.21 BL 8.9 18 466.38 2" Eddy Flow 2.2030 T Len 0.8 Ftg 13.6 C -120 0.00078 Pt 58) 55.958 Pe 0.359 Pt 0.011 58 467.21 RN 8.9 Total 14.5 1 Total Pressure at Node 18) 56.328 psi 77 467.21 2" Eddy Flow 2.2030 1 Len 0.8 Ftg 13.6 C = 120 0.00105 Pt 37) 56.256 Pe -0.359 Pt 0.015 37 466.38 RN 10.4 Total 14.5 57 467.21 2" Eddy Flow 2.2030 III Len 137.5 Ftg 27.3 C = 120 0.00105 Pt 77) 55.911 Pe 0.000 Pt 0.173 77 467.21 BL 10.4 Total 164.8 17 466.38 2" Eddy Flow 2.2030 1 Len 0.8 Ftg 13.6 C = 120 0.00105 Pt 57) 56.084 Pe 0.359 Pt 0.015 57 467.21 RN 10.4 Total 14.5 0 Copyright 2013 Sigma Development Group, Inc. Page 10 of 14 Pipe Information REYNOLDS LOT 20 MEZZANINE From Elv1 Pipe ID T Flows Inside Length ft 1 C Value I Total (Pt) )Si Fitting ft (Pe) psi ft Added 1 GPM Diameter Fittings j Notes To Elev2 Type in Friction Loss I Total Total ft] psi/ft Frict (PQ psi Total Pressure at Node 17) 56.459 psi 76 467.21 2" Eddy Flow 2.2030 1 Len 0.8 Ftg 13.6 c = 120 0.00141 Pt 36) 56.327 Pe -0.359 Pt 0.020 36 466.38 RN 12.2 Total 14.5 56 467.21 2" Eddy Flow 2.2030 TIT Len 137.5 Ftg 27.3 C = 120 0.00141 Pt 76) 55.987 Pe 0.000 Pt 0.232 76 467.21 BL 12.2 Total 164.8 16 466.38 2" Eddy Flow 2.2030 T Len 0.8 Ftg 13.6 = 120 0.00141 Pt 56) 56.220 Pe 0.359 Pt 0.020 56 467.21 RN 12.2 1 Total Pressure at Node 16) 56.600 psi 75 467.21 2" Eddy Flow 2.2030 T Len 0.8 Ftg 13.6 = 120 0.00189 Pt 35) 56.388 Pe -0.359 Pt 0.027 35 466.38 RN 14.3 Total 14.5 55 467.21 2" Eddy Flow 2.2030 171 Len 137.5 Ftg 27.3 C = 120 0.00189 Pt 75) 56.056 Pe 0.000 Pt 0.311 75 467.21 BL 14.3 Total 164.8 15 466.38 2" Eddy Flow 2.2030 T Len 0.8 Ftg 13.6 c = 120 0.00189 Pt 55) 56.367 Pe 0.359 Pt 0.027 55 467.21 RN 14.3 Total 14.5 Total Pressure at Node 15) 56.754 psi 74 467.21 2" Eddy Flow 22030 T Len 0.8 Ftg 13.6 C = 120 0.00250 Pt 34) 56.440 Pe -0.359 Pt 0.036 34 466.38 RN ' 16.7 Total 14.5 54 467.21 2" Eddy Flow 2.2030 171 Len 137.5 Ftg 27.3 C = 120 0.00250 Pt 74) 56.117 Pe 0.000 Pt 0.412 74 467.21 BL 16.7 Total 164.8 14 466.38 2" Eddy Flow 2.2030 T Len 0.8 Ftg 13.6 C = 120 0.00250 Pt 54) 56.528 Pe 0.359 Pt 0.036 54 467.21 RN 16.7 Total 14.5 Total Pressure at Node 14) 56.924 psi 73 467.21 2" Eddy Flow 2.2030 T Len 0.8 Ftg 136 1 c = 120 Total l4i50.003 1[Pt J Pt 33) 56.481 Pe -0.359 0.047 1 33 466.38 RN 19.2 0 Copyright 2013 Sigma Development Group, Inc. Page 11 of 14 UM Pipe Information REYNOLDS LOT 20 MEZZANINE From Elevi ft Pipe ID Flows Added GPM Inside I Diameter Ifl Fittings Length ft J C Value Total (Pt) psi J Notes JFitting ft ( I Elev (Pe) Psi To Ele v2 T Type Friction Loss 1 psi/ft Total ITotal psil 53 467.21 2" Eddy Flow 2.2030 lIT Len 137.5 Ftg 27.3 C= 120 0.00327 Pt 73) 56.169 Pe 0.000 Pt 0.538 73 467.21 BL 19.2 Total 164.8 13 466.38 2' Eddy Flow 2.2030 T Len 0.8 Ftg 13.6 c = 120 0.00327 Pt 53) 56.707 Pe 0.359 Pt 0.047 53 467.21 RN 19.2 Total 14.5 Total Pressure at Node 13) 57.114 Psi 72 467.21 2" Eddy Flow 2.2030 T TLen 0.8T Ftg 13.6 c = 120 0.00421 Pt 32) 56.512 Pe -0.359 Pt 0.061 32 466.38 RN 22.1 Total 14.5 52 467.21 2" Eddy Flow 2.2030 I TIT I Len 137.5 Ftg 27.3 C= 120 0.00421 Pt 72) 56.213 Pe 0.000 Pt 0.694 72 467.21 BL 22.1 12 466.38 2" Eddy Flow 2.2030 1 Len 0.8 Ftg 13.6 C = 120 0.00421 Pt 52) 56.907 Pe 0.359 Pt 0.061 52 467.21 RN 22.1 Total 14.5 Total Pressure at Node 12) 57.327 psi 71 467.21 2" Eddy Flow 2.2030 1 Len 0.8 Ftg 13.6 C = 120 0.00468 Pt 31) 56.532 Pe -0.359 Pf 0.068 31 466.38 RN 23.4 Total 14.5 51 467.21 2" Eddy Flow 2.2030 TIT Len 137.5 Ftg 27.3 C = 120 0.00468 Pt 71) 56.240 Pe 0.000 Pt 0.771 71 467.21 BL 23.4 Total 164.8 1 11 466.38 2" Eddy Flow 2.2030 1 Len 0.8 Ftg 13.6 C= 120 0.00468 Pt 51) 57.011 Pe 0.359 Pt 0.068 51 467.21 RN 23.4 Total 14.5 6 466.38 4" Eddy Flow 63.2 4.3100 0 Len 5.0 Ftg 0.0 C = 120 0.00201 Pt 11) 57.439 Pe 0.000 Pt 0.010 11 466.38 CMI 86.5 Total 5.0 Total Pressure at Node 6) 57.449 Psi 20 466.38 4" Eddy Flow 4.3100 2E Len 90.0 Ftg 27.9 C = 120 0.01074 Pt 21) 54.827 Pe 0.000 P1 1.266 21 466.38 CMI 214.3 Total 117.9 19 466.38 4 Eddy Flow 6.9 4.3100 0 Len 10.0 Ftg 0.0 C = 120 0.01139 Pt 20) 56.093 We 0.000 Pt 0.114 20 466.38 CM1 221.2 Total 10.0 © Copyright 2013 Sigma Development Group, Inc. Page 12 of 14 9@8900- zw Pipe Information REYNOLDS LOT 20 MEZZANINE From Elevi ft Pipe ID I I Flows Added I GPM I I Inside I Diameter in Fittings I Length 1t I I I C Value I I Total (Pt) psi T Notes I Fitting ft I Elev (Pe) psi Fd ct(P psi1 To Elev2 Type I Friction Loss 1 psi/ft Total 1T0 18 466.38 4" Eddy Flow 7.7 4.3100 0 Len 10.0 Ftg 0.0 c = 120 0.01214 Pt 19) 56.207 Pe 0.000 Pt 0.121 19 466.38 CM1 228.9 Total 10.0 17 466.38 4" Eddy Flow 8.9 4.3100 0 Len 10.0 Ftg 0.0 C = 120 0.01303 Pt 18) 56.329 Pe 0.000 Pf 0.130 18 466.38 CM1 237.8 Total 10.0 16 466.38 4" Eddy Flow 10.4 4.3100 0 Len 10.0 Ftg 0.0 C = 120 0.01410 Pt 17) 56.459 Pe 0.000 Pt 0.141 17 466.38 CM1 248.2 Total 10.0 15 466.38 4" Eddy Flow 12.2 4.3100 0 Len 10.0 Ftg 0.0 C = 120 Pt 16) 56.600 Pe 0.000 Pt 0.154 16 466.38 CM1 260.5 0.01541 Total 10.0 14 466.38 4" Eddy Flow 14.3 4.3100 0 Len 10.0 Ftg 0.0 C = 120 0.01702 Pt 15) 56.754 Pe 0.000 Pt 0.170 15 466.38 CM1 274.8 Total 10.0 13 466.38 4" Eddy Flow 16.7 4.3100 0 Len 10.0 Ftg 0.0 C = 120 0.01897 Pt 14) 56.924 Pe 0.000 P1 0.190 14 466.38 CM1 291.4 Total 10.0 12 466.38 4" Eddy Flow 19.2 4.3100 0 Len 10.0 Ftg 0.0 C = 120 0.02135 Pt 13) 57.114 Pe 0.000 Pt 0.214 13 466.38 CM1 310.7 Total 10.0 6 466.38 4" Eddy Flow 22.1 Len 5.0 Ftg 0.0 C = 120 0.02425 Pt 12) 57.328 Pe 0.000 Pt 0.121 12 466.38 CM1 332.7 Total 5.0 Total Pressure at Node 6) 57.449 psi 210 449.38 3" Eddy Flow 3.3340 E Len 18.0 Ftg 10.5 C = 120 0.02836 Pt 211) 49.051 Pe 0.000 Pt 0.808 211 449.38 FM 184.2 Total 28.5 201 449.38 3" Eddy Flow 235.0 3.3340 E Len 20.5 Ftg 10.5 C = 120 0.12985 Pt 210) 49.859 Pe 0.000 Pt 4.025 210 449.38 FM 419.3 Total 31.0 200 466.38 3" Eddy Flow 3.3340 T,E Len 26.0 Ftg 33.0 C = 120 0.12985 Pt 201) 53.884 Pe -7.361 Pt 7.659 201 449.38 FM 419.3 Total 590 Total Pressure at Node 2001 54.182 nsi 0 Copyright 2013 Sigma Development Group, Inc. Page 13 of 14 VA OO Pipe Information REYNOLDS LOT 20 MEZZANINE From Elevi ft Pipe ID T Flows Added GPM Inside Diameter in Fittings I Length ft C Value Friction Loss psi/ft I Total (Pt) psi Notes Fitting ft 1Total Elev (Pe) DSI To Elev2 Type Total ft Frict (P psi 5 466.38 6" Sch 10 6.3570 T Len 16.8 Ftg 37.7 C = 120 0.00560 Pt 6) 57.449 Pe 0.000 Pt 0.305 6 466.38 FM 419.3 Total 545 4 436.13 6 Sch 10 6.3570 E Len 30.3 Ftg 17.6 C = 120 0.00560 Pt 5) 57.754 Pe 13.098 Pt 0.268 5 466.38 FR 419.3 Total 479 2 436.13 8" DI 8.4500 E Len 5.0 Ftg 31.6 c = 140 0.00105 Pt 4) 71.129 Pe 0.000 Pt 0.039 4 436.13 UN 419.3 Total 36.6 1 436.13 8" PVC CL200 100.0 7.6800 TJCVIGV ,2E Len 70.0 Ftg 150.3 c = 150 0.00219 Pt 2) 71.168 Pe 0.000 Pt 0.483 2 436.13 UN 519.3 Total 220.3 0 420.00 8" PVC CUOO 76800 GVI2EE Len 250.0 Ftg 71.4 C = 150 0.00219 Pt1) 71. 651 Pe 6.984 Pt 0.705 7 psi loss for DCDA shown as elevation 1 436.13 UN 519.3 Total 321.4 Total Pressure at Node 0) 79.340 psi © Copyright 2013 Sigma Development Group, Inc. Page 14 of 14 2842 WHIPTAIL LOOP CARLSBAD, CA 92010 contract # EPIC FIRE PROTECTION, INC. 765 TURTLE POINT WAY SAN MARCOS, CA 92069 calculated by ADAM BOISVERT telephone 760-310-6122 fax 760-798-0556 email EPICFIRE@COX.NET WHO' Hydraulics Summary Sheet ? r Project Information Calculation Date: 9/27/2018 10:34:59 AM - I REYNOLDS LOT 20 system ID drawing ref 2 OD 2 building NEW construction Ill-B occupancy B, F-i, S-I authority CARLSBAD FD Hydraulics Criteria - density ESFR 20PSI G system type WET design std NFPA 13, 2016 remote area 12 HEADS ft2 hazard EXTRA spr coverage 100 ft2 sprs flowing 12 figure calc'd volume 1,652.3 gal curve Flow Test static pressure 108.90 psi Sprinklers in Remote ____________________ residual pressure 81.00 psi No. Mfgr Mod SIN# Size K 1 quantity flowing 8,000.0 GPM I elevation from if 420.00 ft { 12 VIKING I ESFR VK5I 0 1 25.2 date & time of flow test 8-20-18 location of flow test site 160 Remote Area 1 - Supply / Demand 107.44 psi available at Sprinkler Demand of 93.18 psi 140 with System Flow of 1,621.2 GPM I Mariin: +13.3% b 120 100 40 20 N185 0 1,621.3 GPM 0250 500 750 1000 1250 1500 1750 2000 Water Flow (GPM) 0 Copyright 2013 Sigma Development Group, Inc. Page 1 of 12 08800' DashboanlHydraulks Supply Analysis REYNOLDS LOT 20 (Remote Area 1) Sprinkler Flow; 1,371.2 GPM Additional Flows; 250.0 GPM Hose Flow at Zero; None Total System Flow; 1,621.3 GPM Maximum velocity in pipe 6 - 12 is 23.9 ft/sec Nodes Analysis Minimum Node Actual Node Etev Device KFactor Flow Pressure Discharge Notes ft GPM psi GPM 109 467.2 Sprinkler 25.20 112.70 20.00 112.70 110 467.2 Sprinkler 25.20 112.70 20.03 112.79 105 467.2 Sprinkler 25.20 112.70 20.06 112.87 106 467.2 Sprinkler 25.20 112.70 20.09 112.96 101 467.2 Sprinkler 25.20 112.70 20.26 113.42 102 467.2 Sprinkler 25.20 112.70 20.29 113.51 108 467.2 Sprinkler 25.20 112.70 20.61 114.40 104 467.2 Sprinkler 25.20 1 112.70 20.68 114.59 100 467.2 Sprinkler 25.20 112.70 20.89 115.17 111 467.2 Sprinkler 25.20 112.70 21.19 115.99 107 467.2 1 Sprinkler 25.20 112.70 21.24 116.14 103 467.2 Sprinkler 25.20 112.70 21.44 116.68 2 436.1 Hose Flow 76.43 250.0 © Copyright 2013 Sigma Development Group, Inc. Page 2 of 12 (M8800" Pipe Information REYNOLDS LOT 20 (Remote Area 1) From Elevi ft pipe ID I I Flows Added GPM Inside Diameter in Fittings Length ft I C Value [Total (Pt) psi Notes Fitting ft I I Elev (Pe) I [Fnct (Pf) psi To Elev2 Type I Friction Loss [ psi/ft Total Total ft 110 467.21 2" Eddy Flow 2.2030 Len 10.0 Ftg 0.0 C = 120 0.00329 Pt 109) 20.002 Pe 0.000 Pf 0.033 109 467.21 BL 19.3 Total 10.0 111 467.21 2" Eddy Flow 112.8 2.2030 Len 10.0 Ftg 0.0 C = 120 0.11533 Pt 110) 20.035 Pe 0.000 Pf 1.153 110 467.21 BL 132.1 Total 10-0 1 80 467.21 2" Eddy Flow 116.0 2.2030 T Len 37.5 Ftg 13.6 C = 120 0.37006 Pt 111) 21.188 Pe 0.000 Pr 18.924 111 467.21 BL 248.1 Total 51.1 40 466.38 2" Eddy Flow 2.2030 T Len 0.8 Ftg 13.6 c = 120 0.37006 Pt 80) 40.112 Pe 0.359 Pf 5.354 80 - .21 467 . RN 2481 Total 14.5 Total Pressure at Node 40) 45.826 psi 108 467.21 2" Eddy Flow 2.2030 Len 10.0 Ftg 0.0 C = 120 0.06070 Pt 109) 20.002 Pe 0.000 Pt 0.607 109 467.21 BL 93.4 Total 10.0 60 467.21 2" Eddy Flow 114.4 2.2030 1 Len 70.0 Ftg 13.6 C= 120 0.26654 Pt 108) 20.609 Pe 0.000 Pf 22.293 108 467.21 BL 207.8 Total 83.6 20 466.38 2" Eddy Flow 2.2030 T Len 0.8 Ftg 13.6 c = 120 0.26654 Pt 60) 42.901 Pe 0.359 Pt 3.856 60 467.21 RN 207.8 Total 14.5 Total Pressure at Node 20) 47.117 psi 106 467.21 2" Eddy Flow 2.2030 Len 10.0 Ftg 0.0 C = 120 0.00315 Pt 105) 20.063 Pe 0.000 Pt 0.032 105 467.21 BL 18.9 Total 10.0 107 467.21 2" Eddy Flow 113.0 2.2030 Len 10.0 Ftg 0.0 C = 120 0.11489 Pt 106) 20.094 Pe 0.000 Pt 1.149 106 467.21 BL 131.8 Total 10.0 79 467.21 2" Eddy Flow 116.1 2.2030 T Len 37.5 Ftg 13.6 C = 120 0.36972 Pt 107) 21.243 Pe 0.000 Pt 18.907 107 467.21 BL 248.0 Total 51.1 39 466.38 2" Eddy Flow 2.2030 T Len 0.8 Ftg 13.6 = 120 0.36972 Pt 79) 40.150 Pe 0.359 Pt 5.349 79 467.21 RN 248.0 Total 14.5 Total Pressure at Node 39) 45.859 psi © Copyright 2013 Sigma Development Group, Inc. Page 3 of 12 E j8OO' lks Pipe Information Dathboardffydrau REYNOLDS LOT 20 (Remote Area 1) From Elevi Pipe ID Flows I Inside T Length ft C Value 1 Total (Pt) )SI T ft Added GPM I Diameter Fittings Fitting ft I Elev (Pe) psi Notes To Elev2 Type I in Friction Loss Total Total ft psi Fct (Pfl psi 104 467.21 2" Eddy Flow 2.2030 T Len 10.0 C = 120 0.06144 Pe 0.000 Pt 105) 20.063 Pf 0.614 105 467.21 BL 94.0 ITotal 10.0 59 467.21 2" Eddy Flow 114.6 2.2030 1 Len 70.0 Ftg 13.6 C = 120 0.26844 Pt 104) 20.677 Pe 0.000 Pt 22.452 104 467.21 BL 208.6 Total 83.6 19 466.38 2" Eddy Flow 2.2030 1 Len 0.8 Ftg 13.6 = 120 0.26844 Pt 59) 43.129 Pe 0.359 Pt 3.884 59 467.21 RN 208.6 Total 14.5 Total Pressure at Node 19) 47.373 psi 102 467.21 2" Eddy Flow 2.2030 Len 10.0 Ftg 0.0 C = 120 0.00297 Pt 101) 20.260 Pe 0.000 Pt 0.030 101 467.21 BL 18.3 Total 10.0 103 467.21 2" Eddy Flow 113.5 2.2030 Len 10.0 Ftg 0.0 C = 120 0.11482 Pt 102) 20.290 Pe 0.000 Pt 1.148 102 467.21 BL 131.8 Total 10.0 78 467.21 2" Eddy Flow 116.7 2.2030 1 Len Ftg 13.6 C= 120 0.37106 Pt 103) 21.438 Pe 0.000 Pt 18.976 103 467.21 BL 248.5 Total 51.1 38 466.38 2" Eddy Flow 2.2030 T Len 0.8 Ftg 13.6 = 120 0.37106 Pt 78) 40.413 Pe 0.359 Pt 5.369 78 467.21 RN 248.5 Total 14-51 Total Pressure at Node 38) 46.142 psi 100 467.21 2" Eddy Flow 2.2030 Len 10.0 Ftg 0.0 C= 120 0.06283 Pt 101) 20.260 Pe 0.000 Pt 0.628 101 467.21 BL 95.1 Total 10.0 58 467.21 2" Eddy Flow 115.2 2.2030 1 Len 70.0 Ftg 13.6 C = 120 0.27257 Pt 100) 20.888 1 Pe 0.000 Pt 22.798 100 467.21 BL 210.3 Total 83.6 18 466.38 2" Eddy Flow 2.2030 T Len 0.8 Ftg 13.6 C= 120 0.27257 Pt 58) 43.686 Pe 0.359 Pt 3.944 58 467.21 RN 210.3 Total 14.5 Total Pressure at Node 18) 47.989 psi 39 466.38 4" Eddy Flow 4.3100 0 Len 10.01 Ftg 0.0 C = 120 I-I 0.00332IPf J Pt 40) 45.826 Pe 0.000 0.033 40 466.38 CM2 113.6 Total 10.0 © Copyright 2013 Sigma Development Group, Inc. Page 4 of 12 8OO Da Pipe Information REYNOLDS LOT 20 (Remote Area 1) From Elevi Pipe ID Flows I Inside JLength ft J C Value Total (Pt) psiJ it Added GPM I Diameter Fittings Fitting it 1Total Elev (Pe) psi Notes To EIev2 Type I in Friction Loss Total it1 psi/ft I Frict (PU psi 38 466.38 4' Eddy Flow 248.0 4.3100 0 Len 10.0 Ftg 0.0 C = 120 0.02828 Pt 39) 45.859 Pe 0.000 Pf 0.283 39 466.38 CM2 361.6 Total 10.0 37 466.38 4" Eddy Flow 248.5 4.3100 0 Len 10.0 Ftg 0.0 c = 120 0.07443 Pt 38) 46.142 Pe 0.000 Pf 0.744 38 466.38 CM2 610.1 36 466.38 4" Eddy Flow -38.0 4.3100 0 Len 10.0 Ftg 0.0 C= 120 0.06609 Pt 37) 46.886 Pe 0.000 Pf 0.661 37 466.38 CM2 572.1 Total 10.0 35 466.38 4" Eddy Flow -42.9 4.3100 0 Len 10.0 Ftg 0.0 C= 120 0.05721 Pt 36) 47.547 Pe 0.000 Pf 0.572 36 466.38 CM2 529.2 Total 10.0 34 466.38 4" Eddy Flow -49.0 4.3100 0 Len 10.0 Ftg 0.0 C = 120 Pt 35) 48.119 Pe 0.000 Pf 0.478 35 466.38 CM2 480.2 0.04780 33 466.38 4" Eddy Flow -56.2 4.3100 0 Len 10.0 Ftg 0.0 C= 120 0.03798 Pt 34) 48.597 Pe 0.000 Pt 0.380 34 466.38 CM2 424.1 Total 10.0 32 466.38 4" Eddy Flow -64.3 4.3100 0 Len 10.0 Ftg 0.0 C = 120 0.02802 Pt 33) 48.977 Pe 0.000 Pt 0.280 33 466.38 CM2 359.8 Total 10.0 31 466.38 4" Eddy Flow -73.3 4.3100 0 Len 10.0 Ftg 0.0 C = 120 0.01839 Pt 32) 49.257 Pe 0.000 Pt 0.184 32 466.38 CM2 286.6 30 466.38 4" Eddy Flow -77.4 4.3100 0 Len 10.0 Ftg 0.0 C= 120 0.01027 Pt 31) 49.441 Pe 0.000 Pt 0.103 31 466.38 CM2 209.2 Total 10.0 29 466.38 4" Eddy Flow -75.9 4.3100 0 Len 8.0 Ftg 0.0 c = 120 0.00446 Pt 30) 49.544 Pe 0.000 Pt 0.036 30 466.38 CM2 133.2 Total 8.0 69 467.21 2" Eddy Flow -62.8 2.2030 1 Len 0.8 Ftg 13.6 c = 120 0.03597 Pt 29) 49.580 Pe -0.359 Pt 0.520 29 466.38 RN 70.4 Total 14.5 89 467.21 2" Eddy Flow 2.2030 1 Len 66.0 Ftg 13.6 C = 120 0.03597 Pt 69) 49.741 Pe 0.000 Pt 2.865 69 467.21 BL 70.4 Total 79.6 © Copyright 2013 Sigma Development Group, Inc. Page 5 of 12 08800 iks Pipe Information Dashboard Hydrav REYNOLDS LOT 20 (Remote Area 1) From Elevi ft Pipe ID Flows Added GPM Inside Diameter in Fittings Length ft F C Value 'Friction Loss [ psi/ft ITotal (Pt) psi Notes Fitting ft Elev (Pe) psi To Elev2 T Type Total Total ft 1Fct(l') psi 90 467.21 3" Eddy Flow 62.8 3.3340 T Len 8.0 Ftg 22.5 _ il2]Pt89) 0.01557 52.605 Pe 0.000 Pt 0.475 89 467.21 BL 133.2 Total 30.5 Total Pressure at Node 90) 53.080 psi 28 466.38 4" Eddy Flow 4.3100 0 Len 8.0 Ftg 0.0 = 120 0.00111 Pt 29) 49.580 Pe 0.000 Pt 0.009 29 466.38 CM2 62.8 Total 8.0 68 467.21 2" Eddy Flow 2.2030 T Len 0.8 Ftg 13.6 c = 120 0.02917 Pt 28) 49.589 Pe -0.359 Pt 0.422 28 466.38 RN 62.8 Total 14.5 88 467.21 2" Eddy Flow 2.2030 T Len 66.0 Ftg 13.6 C = 120 0.02917 Pt 68) 49.651 Pe 0.000 Pt 2.323 68 467.21 BL 62.8 Total 79.6 89 467.21 2" Eddy Flow 2.2030 1 Len 8.0 Ftg 13.6 c = 120 0.02917 Pt 88) 51.974 Pe 0.000 Pt 0.631 88 467.21 BL 62.8 Total 21.6 Total Pressure at Node 89) 52.605 psi 70 467.21 2" Eddy Flow 2.2030 1 Len 0.8 Ftg 13.6 = 120 0.04139 Pt 30) 49.544 Pe -0.359 Pt 0.599 30 466.38 RN 75.9 Total 14.5 90 467.21 Eddy Flow 2.2030 T Len 66.0 Ftg 13.6 C = 120 0.04139 Pt 70) 49.783 Pe 0.000 Pf 3.297 70 467.21 BL 75.9 Total 79.6 50 467.21 Eddy Flow 133.2 3.3340 T Len 71.5 Ftg 22.5 C= 120 0.03586 Pt 90) 53.080 Pe 0.000 Pt 3.371 90 467.21 BL 209.2 Total 94.0 10 466.38 3" Eddy Flow 3.3340 1 Len 0.8 Ftg 22.5 C = 120 0.03586 Pt 50) 56.451 Pe 0.359 Pt 0.836 50 467.21 RN 209.2 Total 23.3 11 466.38 4" Eddy Flow 4.3100 0 Len 10.0 Ftg 0.0 C = 120 0.01027 Pt 10) 57.647 Pe 0.000 Pt 0.103 10 466.38 CMI 209.2 Total 10.0 Total Pressure at Node 11) 57.750 psi 41 466.38 4" Eddy Flow 4.3100 0 Len 10.0 Ftg 0.0 0.00454 Pt 40) 45.826 Pe 0.000 Pt 0.045 40 466.38 CM2 134.5 Total 10.0 0 Copyright 2013 Sigma Development Group, Inc. Page 6 of 12 JOO Oash Pipe Information Lard Hydraulics REYNOLDS LOT 20 (Remote Area 1) From Elevi ft I Pipe ID Flows Added GPM Inside Diameter in Fittings Length ft' I C Value J I Total (Pt) PSI Fitting ft I Elev (Pe) psi To ft Elev2 I Type Friction Lossi psi/ft Total Total ft [Frict (PQ psi 42 466.38 4" Eddy Flow ..0.5 4.3100 0 Len 10.0 Ftg 0.0 c = 120 0.00334 Pt 41) 45.871 Pe 0.000 Pf 0.033 41 466.38 CM2 114.0 Total 10.0 43 466.38 4" Eddy Flow -24.1 4.3100 0 Len 10.0 Ftg 0.0 C = 120 0.00215 Pt 42) 45.905 Pe 0.000 Pt 0.022 42 466.38 CM2 89.9 Total 10.0 44 466.38 4" Eddy Flow -23.2 4.3100 0 Len 10.0 Ftg 0.0 C = 120 0.00124 Pt 43) 45.926 Pe 0.000 Pt 0.012 43 466.38 CM2 66.7 Total 10.0 45 466.38 4" Eddy Flow -22.7 4.3100 0 Len 10.0 Ftg 0.0 Pe N=1 Pt 44) 45.939 0.000 Pt 0.006 466.38 CM2 44.0 Total 10.0 46 466.38 4" Eddy Flow -22.2 4.3100 0 Len 12.0 Ftg 0.0 C = 120 0.00016 Pt 45) 45.944 Pe 0.000 Pt 0.002 45 466.38 CM2 21.8 Total 12.0 86 467.21 2" Eddy Flow 2.2030 1 Len 0.8 Ftg 13.6 = 120 0.00412 Pt 46) 45.946 Pe -0.359 Pt 0.060 46 466.38 RN 21.8 Total 14.5 66 467.21 2" Eddy Flow 2.2030 TIT Len 77.0 Ftg 27.3 C = 120 0.00412 Pt 86) 45.646 Pe 0.000 Pt 0.430 86 467.21 BL 21.8 Total 104.3 26 466.38 2" Eddy Flow 2.2030 1 Len 0.8 Ftg 13.6 c = 120 0.00412 Pt 66) 46.076 Pe 0.359 Pt 0.060 66 467.21 RN 21.8 Total 14.5 25 466.38 4" Eddy Flow 4.3100 0 Len 12.0 Ftg 0.0 C = 120 0.00016 Pt 26) 46.496 Pc 0.000 Pt 0.002 26 466.38 CMI 21.8 Total 12.0 Total Pressure at Node 25) 46.498 Psi 85 467.21 2" Eddy Flow 2.2030 1 Len 0.8 Ftg 13.6 C = 120 0 .00425 Pt 45) 45.944 Pc -0.359 Pt 0.061 45 466.38 RN 22.2 Total 14.5 65 467.21 2" Eddy Flow 2.2030 T!T Len 74.0 Ftg 27.3 C = 120 0.00425 Pt 85) 45.646 Pc 0.000 Pt 0.430 85 467.21 BL 22.2 Total 101.3 © Copyright 2013 Sigma Development Group, Inc. Page 7 of 12 Notes 14 88oO thuI Pipe Information REYNOLDS LOT 20 (Remote Area 1) From Elevi ft I Pipe ID I Flows Added GPM Inside Diameter in Fittings Length ft I C Value I Friction Lose psi/ft Total (Pt) psi I Notes Fitting ft Elev (Pe) psi To Elev2 Type Total IbothI ft Frict (Pf) psij 25 468.38 2' Eddy Flow 2.2030 1 Len 0.8 Ftg 13.6 c = 120 0.00425 Pt 65) 46.077 Pe 0.359 Pf 0.061 65 467.21 RN 22.2 Total 14.5 24 466.38 4" Eddy Flow 21.8 4.3100 0 Len 30.5 Ftg 0.0 C = 120 0.00057 Pt 25) 46.498 Pe 0.000 Pt 0.018 25 466.38 CM1 44.0 Total 30.5 Total Pressure at Node 24) 46.515 psi 84 467.21 2" Eddy Flow 2.2030 1 Len 0.8 Ftg 13.6 c = 120 0.00443 Pt 44) 45.939 Pe -0.359 Pt 0.064 44 466.38 RN 22.7 Total 14.5 64 467.21 2" Eddy Flow 2.2030 TIT Len 74.0 Ftg 27.3 C = 120 0.00443 Pt 84) 45.643 Pe 0.000 Pf 0.448 84 467.21 BL 22.7 24 466.38 2" Eddy Flow 2.2030 T Len 0.8 Ftg 13.6 = 120 0.00443 Pt 64) 46.092 Pe 0.359 Pt 0.064 64 467.21 RN 22.7 Total 14.5 23 466.38 4" Eddy Flow 44.0 4.3100 0 Len 10.0 Ftg 0.0 C = 120 0.00124 Pt 24) 46.515 Pe 0.000 Pf 0.012 24 466.38 CM1 66.7 Total 10.0 Total Pressure at Node 23) 46.528 psi 83 467.21 2" Eddy Flow 2.2030 1 Len 0.8 Ftg 136 = 120 0.00462 Pt 43) 45.926 Pe -0.359 Pt 0.067 1 I j 43 466.38 RN 23.2 Total 145 63 467.21 2" Eddy Flow 2.2030 lIT Len 74.0 Ftg 27.3 C = 120 0.00462 Pt 83) 45.633 Pe 0.000 Pf 0.468 83 467.21 BL 23.2 Total 101.3 23 466.38 2° Eddy Flow 2.2030 1 Len 0.8 Ftg 13.6 C = 120 0.00462 Pt 63) 46.101 Pe 0.359 Pf 0.067 63 467.21 RN 23.2 Total 14.5 22 466.38 4" Eddy Flow 66.7 Len 10.01 C = 120 Pt 23) 46.528 23 468.38 CM1 89.9 Total io00215 Pt 0.022 4.3100 0 Ftg 0.0 Pe 0.000 Total Pressure at Node 22) 46.549 psi 82 467.21 2" Eddy Flow Len 0.8J c = 120 Pt 42) 45.905 42 468.38 RN 24.1 Total 14.5 0.00495 Pt 0.072 2.2030 1 Ftg 13.6 Pe -0.359 0 Copyright 2013 Sigma Development Group, Inc. Page 8 of 12 8OO Daw Pipe Information REYNOLDS LOT 20 (Remote Area 1) From Elevi Pipe ID Flows Inside Length ft I C Value Total (Pt) psi I Fitting ft I I Elev (Pe) psi ft Added GPM Diameter Fittings Notes To Elev2 Type In I Friction Loss Total Total ft psi/ft [FriCt (Pt) psi 62 467.21 2" Eddy Flow 2.2030 TIT Len 74.0 Ftg 27.3 c = 120 0.00495 Pt 82) 45.617 Pe 0.000 Pt 0.501 82 467.21 BL 24.1 Total 101.3 22 466.38 2" Eddy Flow 2.2030 1 Len 0.8 Ftg 13.6 C= 120 0.00495 Pt 62) 46.118 Pe 0.359 Pt 0.072 62 467.21 RN 24.1 Total 14.5 21 466.38 4" Eddy Flow 89.9 4.3100 0 Len 10.0 Ftg 0.0 C = 120 0.00334 Pt 22) 46.549 Pe 0.000 Pf 0.033 22 466.38 CM1 114.0 Total Pressure at Node 21) 46.583 psi 81 467.21 2" Eddy Flow 2.2030 1 Len 0.81 Ftg 13.6 c = 120 0.00367 Pt 41) 45.871 Pe -0.359 Pt 0.053 41 466.38 RN 20.5 Total 14.5 61 467.21 2" Eddy Flow 2.2030 lIT Len 137.5 Ftg 27.3 C = 120 0.00367 Pt 81) 45.565 Pe 0.000 Pt 0.605 81 467.21 BL 20.5 Total 164.8 21 466.38 2" Eddy Flow 2.2030 T Len 0.8 Ftg 13.6 C = 120 0.00367 Pt 61) 46.170 Pe 0.359 Pt 0.053 Total 14.5 61 467.21 RN 20.5 20 466.38 4" Eddy Flow 114.0 4.3100 2E Len 90.0 Ftg 27.9 C= 120 0.00454 Pt 21) 46.583 Pe 0.000 pf 0.535 21 466.38 CMI 134.5 Total 117.9 19 466.38 ______ 4" Eddy Flow 207.8 4.3100 0 Len 10.0 Ftg 0.0 C = 120 0.02555 Pt 20) 47.117 Pe 0.000 Pt 0.255 20 466.38 CMI 342.3 Total 10.0 18 466.38 4" Eddy Flow 208.6 4.3100 0 Len 10.0 Ftg 0.0 = 120 0.06161 Pt 19) 47.373 Pe 0.000 Pt 0.616 19 466.38 CMI 550.9 Total 10.0 17 466.38 4" Eddy Flow 210.3 4.3100 0 Len 10.0 Ftg 0.0 C = 120 0.11207 Pt 18) 47.989 Pe 0.000 Pt 1.121 18 466.38 CMI 761.2 Total 10.0 Total Pressure at Node 17) 49.110 psi 77 - 467.21 2" Eddy Flow 2.2030 T Len 0.81 Ftg 13.6 c = 120 T 0.01148 Pt 37) 46.886 Pe -0.359 Pt 0.166 [ 37 466.38 RN 38.0 Total 14.5 0 Copyright 2013 Sigma Development Group, Inc. Page 9 of 12 Dash Pipe Information board HydiuIk.s REYNOLDS LOT 20 (Remote Area 1) From Elevi Pipe ID Flova Added Inside Length ft C Value Total (Pt) PSI (3PM Diameter in Fittings Fitting ft Elev (Pe) psi Notes To Elev2 Type Friction Loss psi/ft Total Total ft Frict (Pf) psi 57 467.21 2" Eddy Flow 2.2030 TIT Len 137.5 Ftg 27.3 C = 120 001148 Pt 77) 46.693 Pe 0.000 Pf 1.891 77 467.21 BL 38.0 Total 164.8 17 466.38 2" Eddy Flow 2.2030 1 Len 0.8 Ftg 13.6 C= 120 0.01148 Pt 57) 48.584 Pe 0.359 Pf 0.166 57 467.21 RN 38.0 Total 14.5 16 466.38 4" Eddy Flow 761.2 4.3100 0 Len 10.0 Ftg 0.0 C = 120 0.12263 Pt 17) 49.110 Pe 0.000 Pt 1.226 17 466.38 CMI 799.1 Total 10.0 Total Pressure at Node 16) 50.336 psi 76 467.21 2" Eddy Flow 2.2030 T Len 0.8 Ftg 13.6 C = 120 0.01440 Pt 36) 47.547 Pe -0.359 Pf 0.208 36 466.38 RN 42.9 Total 14.5 56 467.21 2" Eddy Flow 2.2030 lIT Len 137.5 Ftg 27.3 C = 120 0.01440 Pt 76) 47.396 Pe 0.000 Pt 2.372 76 467.21 BL , 42.9 Total 164.8 16 466.38 2" Eddy Flow 2.2030 1 Len 0.8 Ftg 13.6 C = 120 0.01440 Pt 56) 49.768 Pe 0.359 Pt 0.208 56 467.21 RN 42.9 Total 14.5 15 466.38 4" Eddy Flow 799.1 4.3100 0 Len 10.0 Ftg 0.0 C = 120 0.13508 Pt 16) 50.336 Pe 0.000 Pt 1.351 16 466.38 CMI 842.0 Total 10.0 Total Pressure at Node 15) 51.687 psi 75 467.21 2" Eddy Flow 2.2030 1 Len 0.8 Ftg 13.6 C = 120 0.01842 Pt 35) 48.119 Pe -0.359 Pt 0.266 35 466.38 RN 49.0 Total 14.5 55 467.21 2" Eddy Flow 2.2030 lIT Len 137.5 Ftg 27.3 C = 120 0.01842 Pt 75) 48.026 Pe 0.000 Pt 3.035 75 467.21 BL 49.0 Total 164.8 15 466.38 2' Eddy Flow 2.2030 1 Len 0.8 Ftg 13.6 C= 120 0.01842 Pt 55) 51.060 Pe 0.359 Pt 0.266 55 467.21 RN 49.0 Total 14.5 1 14 466.38 4" Eddy Flow 842.0 4.3100 0 Len 10.0 1 Ftg 0.0 C = 120 Pt 15) 51.687 Pe 0.000 Pt 1.500 15 466.38 CMI 891.0 1jf199 jTotal Total Pressure at Node 14) 53.187 psi © Copyright 2013 Sigma Development Group, Inc. Page 10 of 12 I8OO" Da dHydrauIks Pipe Information shboa' REYNOLDS LOT 20 (Remote Area 1) From Elevi ft Pipe ID Flows T Added I GPM I Inside Diameter Fittings jTotal 'Length ttT C Value 1 Friction Loss psi/fl Total (Pt) )S Notes Fitting ft Elev (Pe) psi To EIev2 Type I Tobl ft1 Fact (P0 psi 74 467.21 2" Eddy Flow 2.2030 T Len 0.8 Ftg 13.6 c = 120 0 .02369 Pt 34) 48.597 Pe -0.359 pf 0.343 34 466.38 RN 56.2 Total 14.5 54 467.21 2' Eddy Flow 2.2030 TIT Len 137.5 Ftg 27.3 C = 120 0.02369 Pt 74) 48.581 Pe 0.000 Pt 3.903 74 467.21 BL 56.2 Total 164.8 14 466.38 2" Eddy Flow 2.2030 1 Len 0.8 Ftg 13.6 c = 120 0.02369 Pt 54) 52.484 Pe 0.359 Pt 0.343 54 467.21 RN 56.2 Total 14.5 13 466.38 4" Eddy Flow 891.0 4.3100 0 Len 10.0 Ftg 0.0 C = 120 0.16794 Pt 14) 53.187 Pe 0.000 Pt 1.679 14 466.38 CM1 947.2 Total 10.0 1 Total Pressure at Node 13) 54.866 psi 73 467.21 2" Eddy Flow 2.2030 1 Len 0.8 Ftg 13.6 c = 120 0.03040 Pt 33) 48.977 Pe -0.359 Pt 0.440 33 466.38 RN 64.3 Total 14.5 53 467.21 2" Eddy Flow 2.2030 TIT Len 137.5 Ftg 27.3 C = 120 0.03040 Pt 73) 49.057 Pe 0.000 N 5.009 73 467.21 BL 64.3 Total 164.8 13 466.38 2" Eddy Flow 2.2030 1 Len 0.8 Ftg 13.6 c = 120 0.03040 Pt 53) 54.066 Pe 0.359 Pt 0.440 53 467.21 RN 64.3 Total 14.5 12 - 466.38 4" Eddy Flow 947.2 4.3100 0 Len 10.0 Ftg 0.0 C = 120 0.18962 Pt 13) 54.866 Pe 0.000 Pt 1.896 13 466.38 CM1 1,011.4 Total 10.0 Total Pressure at Node 12) 56.762 psi 72 467.21 2" Eddy Flow 2.2030 T Len 0.8 Ftg 13.6 C = 120 0.03874 Pt 32) 49.257 Pe -0.359 Pt 0.561 32 466.38 RN 73.3 Total 14.5 52 467.21 2" Eddy Flow 2.2030 TIT Len 137.5 Ftg 27.3 C = 120 Pt 72) 49.458 Pe 0.000 Pt 6.384 72 467.21 BL 73.3 0.03874 Total 164.8 12 466.38 2" Eddy Flow 2.2030 1 Len 0.8 Ftg 13.6 C = 120 0.03874 Pt 52) 55.842 Pe 0.359 Pt 0.561 52 467.21 RN 73.3 Total 14.5 © Copyright 2013 Sigma Development Group, Inc. Page 11 of 12 a ) REYNOLDS LOT 20 Das*boa,dHydraulks Pipe Information (Remote Area 1) From Elevi ft Pipe ID Flows Added GPM Inside Diameter Fittings Length ft [ C Value Friction Loss' ITotal Pt) psi Notes Fitting ft Elev (Pe) psi To Elev2 in Type [ psi/ft Total Total ft Fnct (Pt) psi 6 466.38 4" Eddy Flow 1,011.4 4.3100 Len 5.0 Ftg 0.0 C 0.21581 _il29_jPtl2) 56.762 Pe 0.000 pf 1.079 12 466.38 CMI 1,084.7 Total 5.0 Total Pressure at Node 6) 57.841 Psi 71 467.21 2" Eddy Flow 2.2030 1 Len 0.8 Ftg 13.6 C= 120 0.04289 Pt 31) 49.441 Pe -0.359 Pt 0.621 31 466.38 RN 774 Total 14.5 51 467.21 2" Eddy Flow 2.2030 T!T Len 137.5 Ftg 27.3 C = 120 0.04289 Pt 71) 49.702 Pe 0.000 Pt 7.067 71 467.21 BL 77.4 Total 164.8 11 466.38 2" Eddy Flow 2.2030 1 Len 0.8 Ftg 13.6 C = 120 Pt51) 56.769 Pe 0.359 Pt 0.621 51 467.21 RN 77.4 0.04289 Total 14.5 6 466.38 4" Eddy Flow 209.2 4.3100 0 Len 5.0 Ftg 0.0 C = 120 0.01839 Pt 11) 57.749 Pe 0.000 Pt 0.092 H 11 466.38 CMI 286.6 Total 5.0 5 466.38 6" Sch 10 1,084.7 6.3570 T Len 16.8 Ftg 37.7 C = 120 0.05017 Pt 6) 57.841 Pe 0.000 Pt 2.733 6 466.38 FM 1,371.3 Total 54.5 4 436.13 6" Sch 10 6.3570 E Len 30.3 Ftg 17.6 C = 120 0.05017 Pt 5) 60.574 Pe 13.098 Pt 2.401 5 466.38 FR 1,371.3 Total 47.9 2 436.13 8" Dl 8.4500 E Len 5.0 Ftg 31.6 C = 140 0.00943 Pt 4) 76.083, Pe 0.000 Pt 0.345 4 436.13 UN 1,371.3 Total 36.6 1 436.13 8" PVC CL200 250.0 7.6800 T,CV!GV Len 70.0 Ftg 150.3 C = 150 0.01803 Pt 2) 76.428 Pe 0.000 Pt 3.970 2 436.13 UN 1,621.3 Total 220.3 0 420.00 8" PVC C1200 76800 GV!2EE Len 250.0 Ftg 71.4 C = 150 0.01803 Pt 1) 80.399 Pe 6.984 Pt 5.793 7psi loss for DCDA shown as elevation 1 436.13 UN 1,621.3 Total 321.4 Total Pressure at Node 0) 93.176 psi © Copyright 2013 Sigma Development Group, Inc. Page 12 of 12 Da Hydraulics Summary Sheet p'. thbcardHydmuIi Project Information Calculation Date: 9/27/2018 10:36:50 AM IREYNOLDS LOT 20 system ID drawing ref 2 OF 2 building NEW construction Ill-B occupancy B, F-i S-i authority CARLSBAD FD Hydraulics Criteria - density ESFR 20PSI G system type WET design std NFPA 13, 2016 remote area 12 HEADS ft2 hazard EXTRA spr coverage 100 ft' sprs flowing 12 figure calc'd volume 1,652.3 gal curve FIw TgicI static pressure 108.90 psi residual pressure 81.00 psi quantity flowing 8,000.0 GPM elevation from if 420.00 ft date & time of flow test 8-20-18 location of flow test site 2842 WHIPTAIL LOOP CARLSBAD, CA 92010 contract # Tnfa..m 14 nn EPIC FIRE PROTECTION, INC. 765 TURTLE POINT WAY SAN MARCOS, CA 92069 calculated by ADAM BOISVERT telephone 760-310-6122 fax 760-798-0556 email EPICFIRE@COX.NET - Sprinklers in Remote No. Mfgr Mod SIN# Size K 12 I VIKING I ESFR I. VK510 I 1' 1 25.2 emote Area 2- supply / uemana 107.29 psi available at I Sprinkler Demand of 100.37 psi with System Flow of 1,710.3 GPM J I Mariin: +6.5% 120 100 to CL 40 20 0 I I I 1 1 1,710.3 - GPM N185 0250 500 750 1000 1250 1500 1750 2000 Water Flow (GPM) 0 Copyright 2013 Sigma Development Group, Inc. Page 1 of 12 160 140 / Pressure / Total / System Available / Flow 107.29 psi 1,7103 GPM (Remote Area 2) Total Pressure 100.37 psi REYNOLDS LOT 20 800 Supply Analysis / Source Static / Residual / Quantity Node re /Press, / Pressure / Flowing Zero 108.90 psi I 81.00 psi 8,000.0 GPM ( Sprinkler Flow: 1,460.3 GPM Additional Flows: 250.0 GPM Hose Flow at Zero: None Total System Flow: 1,710.3 GPM Maximum velocity in pipe 28-68 is 24.2 ft/sec Nodes Analysis Minimum Node Actual Node Elev Device KFactor Flow Pressure Discharge Notes ft GPM psi GPM 122 467.2 Sprinkler 25.20 112.70 20.00 112.70 121 467.2 Sprinkler 25.20 112.70 20.23 113.35 123 467.2 Sprinkler 25.20 112.70 20.25 113.39 120 467.2 Sprinkler 25.20 112.70 22.05 118.33 126 467.2 Sprinkler 25.20 112.70 22.99 120.83 125 467.2 Sprinkler 25.20 112.70 23.06 121.00 127 467.2 Sprinkler 25.20 112.70 23.59 122.38 124 467.2 Sprinkler 25.20 112.70 24.50 124.74 130 467.2 Sprinkler 25.20 112.70 25.42 127.05 129 467.2 Sprinkler 25.20 1 112.70 25.42 127.06 131 467.2 Sprinkler 25.20 112.70 26.38 129.42 128 467.2 Sprinkler 25.20 112.70 26.62 130.01 2 436.1 Hose Flow 82.60 250.0 0 Copyright 2013 Sigma Development Group, Inc. Page 2 of 12 REYNOLDS LOT 20 Pipe Information (Remote Area 2) Dashboard Hydraulics From Elevi Pipe ID Flows Added GPM Inside T Diameter Fittings Length ft [ C Value IT0thl (Pt) psi Notes Fitting ft Elev (Pe) psi Frict (PQ psi To Elev2 Type Friction Loss [ psi/ft Total Total ft 131 467.21 2" Eddy Flow 2.2030 Len 10.0 Ftg 0.0 - C - 120 Total 1000.O9586Pt Pt 130) 25.418 Pe 0.000 0.959 130 467.21 BL 119.6 90 467.21 2" Eddy Flow 129.4 2.2030 Ftg 0.0 0.37244 131) 26.377 Pe 0.000 Pt 2.514 131 467.21 BL 249.0 Total 6.8 Total Pressure at Node 90) 28.891 psi 129 467.21 2" Eddy Flow 2.2030 Len 10.0 Ftg 0.0 C -120 0.00057 Pt 130) 25.418 Pe 0.000 Pt 0.006 130 467.21 BL 7.5 Total 10.0 128 467.21 2" Eddy Flow 127.1 2.2030 Len 10.0 Ftg 0.0 C = 120 0.11931 Pt 129) 25.423 Pe 0.000 Pt 1.193 129 467.21 BL 134.6 Total 10.0 70 467.21 2" Eddy Flow 130.0 2.2030 T Len 29.3 Ftg 13.6 C = 120 0.41675 Pt 128) 26.616 Pe 0.000 Pf 17.874 128 467.21 BL 264.6 Total 42.9 30 466.38 2' Eddy Flow 2.2030 1 Len 0.8 Ftg 13.6 C = 120 0.41675 Pt 70) 44.490 Pe 0.359 Pt 6.030 70 467.21 RN ____________ 264.6 Total 14.5 Total Pressure at Node 30) 50.880 psi 127 467.21 2" Eddy Flow 2.2030 Len 10.0 Ftg 0.0 C = 120 0 0 . 5968 Pt 126) 22.989 Pe 0.000 Pt 0.597 126 467.21 BL 92.5 Total 10.0 89 467.21 2" Eddy Flow 122.4 2.2030 Len 6.8 Ftg 0.0 C= 120 0.28372 Pt 127) 23.586 Pe 0.000 Pt 1.915 127 467.21 BL 214.9 Total 6.8 Total Pressure at Node 89) 25.501 psi 125 467.21 2' Eddy Flow Len 10.0 Pt 126) 22.989 2.2030 Ftg 0.0 Pe 0.000 126 467.21 BL 28.3 io.1 0.00666 Pt 0.067 Total 124 467.21 2" Eddy Flow 121.0 2.2030 Len 10.0 Ftg 0.0 C = 120 0.14459 Pt 125) 23.055 Pe 0.000 Pt 1.446 125 467.21 BL 149.3 Total 10.0 69 467.21 2" Eddy Flow 124.7 2.2030 T _______ Len 29.3 Ftg 13.6 C = 120 0.44473 Pt 124) 24.501 Pe 0.000 Pt 19.074 124 467.21 BL 274.0 Total 42.9 © Copyright 2013 Sigma Development Group, Inc. Page 3 of 12 EiJOO Dash Pipe Information K!!2 Hydraull REYNOLDS LOT 20 (Remote Area 2) From ft Pipe ID T Flows Added GPM Inside Diameter in Fittings I Length ft C Value Friction Loss psi/ft Total (Pt) psi I Notes Fitting ft Elev (Pe) psi To Elev2 ft Type Total Total ft FriCt (Pf) psi 29 466.38 2" Eddy Flow 2.2030 1 274.0 Len 0.8 Ftg 13.61- J c = 120 0.44473 Pt 69) 43.575 Pe 0.359 Pf 6.435 69 467.21 RN Total 14.5 Total Pressure at Node 29) 50.370 psi 123 467.21 2" Eddy Flow 2.2030 Len 10.0 Ftg 0.0 C = 120 0.02453 Pt 122) 20.001 Pe 0.000 Pt 0.245 122 467.21 BL 57.2 Total 10.0 88 467.21 2" Eddy Flow 113.4 2.2030 Len 6.8 Ftg 0.0 c = 120 0.18510 Pt 123) 20.246 Pe 0.000 Pt 1.249 -1 123 467.21 BL 170.6 Total 6.8 89 467.21 2" Eddy Flow 2.2030 T Len 8.0 Ftg 13.6 = 120 0.18510 Pt 88) 21.496 Pe 0.000 Pt 4.005 88 467.21 BL 170.6 Total 21.6 90 467.21 3" Eddy Flow 214.9 3.3340 T Len 8.0 Ftg 22.5 C = 120 0.11118 Pt 89) 25.501 Pe 0.000 Pt 3.390 89 467.21 BL 385.5 Total 30.5 50 467.21 3" Eddy Flow 249.0 3.3340 T Len 71.5 Ftg 22.5 C = 120 0.27946 Pt 90) 28.891 Pe 0.000 Pt 26.266 90 467.21 BL 634.5 Total 94.0 10 466.38 3" Eddy Flow 3.3340 1 Len 0.8 Ftg 22.5 C= 120 0.27946 Pt 50) 55.156 Pe 0.359 Pt 6.516 50 467.21 RN 634.5 11 466.38 4" Eddy Flow 4.3100 0 Len 10.0 Ftg 0.0 C = 120 0.08003 Pt 10) 62.032 Pe 0.000 Pt 0.800 10 466.38 CMI 634.5 Total 10.0 Total Pressure at Node 11) 62.833 psi 121 467.21 2" Eddy Flow 2.2030 Len 10.0 Ftg 0.0 C = 120 0.02316 Pt 122) 20.001 Pe 0.000 Pt 0.232 122 467.21 BL 55.5 Total 10.0 120 467.21 2" Eddy Flow 113.4 2.2030 Len 10.0 Ftg 0.0 C = 120 0.18153 Pt 121) 20.232 Pe 0.000 Pt 1.815 121 467.21 BL 168.8 Total 10.0 68 467.21 2" Eddy Flow 118.3 2.2030 1 Len 29.3 Ftg 13.6 C = 120 0.48494 Pt 120) 22.048 Pe 0.000 Pt 20.798 120 467.21 BL 287.2 Total 42.9 0 Copyright 2013 Sigma Development Group, Inc. Page 4 of 12 8800 Pipe Information REYNOLDS LOT 20 (Remote Area 2) From Elv1 ft 1 Pipe ID Flows Added GPM Inside Diameter in Fittings Length ft C Value I Friction Loss I psi/ft [Total (Pt) psi I Notes Fitting ft I Elev (Pe) I To Elev2 Type Total Total ft [Frict (Pt) psi 28 466.38 ? Eddy Flow 2.2030 1 Len 0.8 Ftg 13.6 c = 120 0.48494 Pt 68) 42.846 Pe 0.359 Pt 7.016 68 467.21 RN 287.2 Total 14.5 29 466.38 4" Eddy Flow 4.3100 0 Len 8.0 Ftg 0.0 = 120 0.01846 Pt 28) 50.222 Pe 0.000 Pt 0.148 28 466.38 CM2 287.2 30 466.38 4" Eddy Flow 274.0 4.3100 0 Len 8.0 Ftg 0.0 c = 120 0.06377 Pt 29) 50.370 Pe 0.000 Pt 0.510 29 466.38 CM2 561.2 Total 8.0 31 466.38 4" Eddy Flow 264.6 4.3100 0 Len 10.0 Ftg 0.0 C = 120 Pt 30) 50.880 Pe 0.000 Pt 1.303 30 466.38 CM2 825.8 0.13029 Total 10.0 32 466.38 4" Eddy Flow -88.5 4.3100 0 Len 10.0 Ftg 0.0 C = 120 0.10564 Pt 31) 52.184 Pe 0.000 Pt 1.056 31 466.38 CM2 737.2 Total 10.0 33 466.38 4" Eddy Flow -83.6 4.3100 0 Len 10.0 Ftg 0.0 C = 120 0.08456 Pt 32) 53.240 Pe 0.000 Pt 0.846 32 466.38 CM2 653.7 34 466.38 4" Eddy Flow -75.2 4.3100 0 Len 10.0 Ftg 0.0 C = 120 0.06744 Pt 33) 54.086 Pe 0.000 Pt 0.674 33 466.38 CM2 578.4 Total 10.0 35 466.38 4" Eddy Flow -68.0 4.3100 0 Len 10.0 Ftg 0.0 C = 120 0.05352 Pt 34) 54.760 Pe 0.000 Pt 0.535 34 466.38 CM2 510.5 Total 10.0 36 466.38 4" Eddy Flow .61.7 4.3100 0 Len 10.0 Ftg 0.0 C = 120 Pt 35) 55.295 Pe 0.000 Pt 0.422 35 466.38 CM2 448.8 0.04217 Total 10.0 37 466.38 4" Eddy Flow -56.4 4.3100 0 Len 10.0 Ftg 0.0 C = 120 0.03289 Pt 36) 55.717 Pe 0.000 Pt 0.329 36 466.38 CM2 392.4 Total 10.0 38 466.38 4" Eddy Flow -51.9 4.3100 0 Len 10.0 Ftg 0.0 C = 120 0.02530 Pt 37) 56.046 Pe 0.000 Pt 0.253 37 466.38 CM2 340.5 Total 10.0 39 466.38 4" Eddy Flow -48.2 4.3100 0 Len 10.0 Ftg 0.0 C = 120 0.01908 Pt 38) 56.299 Pe 0.000 Pt 0.191 38 466.38 CM2 292.3 Total 10.0 0 Copyright 2013 Sigma Development Group, Inc. Page 5 of 12 REYNOLDS LOT 20 Pipe Information (Remote Area 2) From Elevi ft Pipe ID Flows Added T Inside T Length ft [ C Value ] Total (Pt) psi T I GPM I Diameter I in Fittings Fitting ft I Elev (Pe) psi Notes To EIev2 Type Friction Loss [ psi Tothi Totalft Frict(P psil 40 466.38 4" Eddy Flow -45.2 4.3100 0 TLen 10.01 Ftg 0.0 c = 120 Pt 39) 56.490 Pe 0.000 Pt 0.140 39 466.38 CM2 247.1 }Total ioo3 41 466.38 4" Eddy Flow -43.0 4.3100 0 Len 10.0 Ftg 0.0 C = 120 0.00982 Pt 40) 56.630 Pe 0.000 Pt 0.098 40 466.38 CM2 204.2 Total 10.0 42 466.38 4" Eddy Flow -31.1 4.3100 0 Len 10.0 Ftg 0.0 c = 120 0.00723 Pt 41) 56.728 Pe 0.000 Pt 0.072 41 466.38 CM2 173.0 Total 10.0 43 466.38 4" Eddy Flow -36.6 4.3100 0 Len 10.0 Ftg 0.0 __________ C = 120 0.00466 Pt42) 56.801 Pe 0.000 Pt 0.047 42 466.38 CM2 136.5 44 466.38 4" Eddy Flow -35.2 4.3100 0 Len 10.0 Ftg 0.0 C = 120 0.00268 Pt 43) 56.848 Pe 0.000 Pt 0.027 43 466.38 CM2 101.2 Total 10.0 45 466.38 4" Eddy Flow -34.4 4.3100 0 Len 10.0 Ftg 0.0 c = 120 0.00124 Pt 44) 56.874 Pe 0.000 Pt 0.012 44 466.38 CM2 66.8 Total 10.0 46 466.38 4" Eddy Flow -33.7 4.3100 0 Len 12.0 Ftg 0.0 C = 120 0.00034 Pt 45) 56.887 Pe 0.000 Pt 0.004 45 466.38 CM2 33.1 Total 12.0 86 467.21 2" Eddy Flow 2.2030 1 Len 0.8 Ftg 13.6 c = 120 0.00893 Pt 46) 56.891 Pe -0.359 Pt 0.129 46 466.38 RN 33.1 Total 14.5 66 467.21 2" Eddy Flow 2.2030 TIT Len 77.0 Ftg 27.3 C = 120 0.00893 Pt 86) 56.660 Pe 0.000 Pt 0.931 86 467.21 BL 33.1 Total 104.3 26 466.38 2" Eddy Flow 2.2030 T Len 0.8 Ftg 13.6 c = 120 0.00893 Pt 66) 57.592 Pe 0.359 Pt 0.129 66 467.21 RN 33.1 Total 14.5 25 466.38 4" Eddy Flow 4.3100 0 Len 12.0 Ftg 0.0 C= 120 Pt 26) 58.080 Pe 0.000 Pt 0.004 26 466.38 CMI 33.1 0.00034 Total 12.0 Total Pressure at Node 25) 58.084 psi 0 Copyright 2013 Sigma Development Group, Inc. Page 6 of 12 884 7: Pipe Information DashLrtardHydrauIks REYNOLDS LOT 20 (Remote Area 2) From Elevi ft Pipe ID T Flows Added GPM Inside Diameter in Fittings Length ft 1 C Value I Total (Pt) psi Notes Fitting ft Elev (Pe) psi To ft Elev2 1 Type Friction Loss J_Total Total ft psvft Frict (P0 psi 85 467.21 2" Eddy Flow 2.2030 1 Len 0.8 Ftg 13.6 c = 120 0.00920 Pt 45) 56.887 Pe -0.359 Pt 0.133 45 466.38 RN 33.7 Total 14.5 65 467.21 2" Eddy Flow 2.2030 lIT Len 74.0 Ftg 27.3 C = 120 0.00920 Pt 85) 56.660 Pe 0.000 Pt 0.931 85 467.21 BL 33.7 Total 101.3 25 466.38 2" Eddy Flow 2.2030 T Len 0.8 Ftg 13.6 C = 120 0.00920 Pt 65) 57.592 Pe 0.359 Pt 0.133 65 467.21 RN 33.7 Total 14.5 24 466.38 4" Eddy Flow 33.1 4.3100 0 Len 30.5 Ftg 0.0 C = 120 0.00124 Pt 25) 58.084 Pe 0.000 Pt 0.038 25 466.38 CMI 66.8 Total 30.5 Total Pressure at Node 24) 58.122 psi 84 467.21 2" Eddy Flow 2.2030 T Len 0.8 Ftg 13.6 c = 120 0.00958 Pt 44) 56.874 Pe -0.359 Pt 0.139 44 466.38 RN 34.4 Total 14.5 64 467.21 2" Eddy Flow 2.2030 T!T Len 74.0 Ftg 27.3 C = 120 0.00958 Pt 84) 56.653 Pe 0.000 Pt 0.971 84 467.21 BL 34.4 Total 101.3 24 466.38 2" Eddy Flow 2.2030 1 Len 0.8 Ftg 13.6 c = 120 0.00958 Pt 64) 57.624 Pe 0.359 Pt 0.139 64 467.21 RN 34.4 Total 14.5 1 23 466.38 4" Eddy Flow 66.8 4.3100 0 Len 10.0 Ftg 0.0 C = 120 0.00268 Pt 24) 58.122 Pe 0.000 Pt 0.027 24 466.38 CMI 101.2 Total 10.0 Total Pressure at Node 23) 58.149 psi 83 467.21 2" Eddy Flow 2.2030 1 Len 0.8 Ftg 13.6 c = 120 0.01000 Pt 43) 56.848 Pe -0.359 Pt 0.145 43 466.38 RN 35.2 Total 14.5 63 467.21 2" Eddy Flow 2.2030 TIT Len 74.0 Ftg 27.3 C = 120 0.01000 Pt 83) 56.633 Pe 0.000 Pt 1.012 83 467.21 BL 35.2 23 466.38 2" Eddy Flow 2.2030 1 Len 0.8 Ftg 13.6 C = 120 0.01000 Pt 63) 57.645 Pe 0.359 Pt 0.145 63 467.21 RN 35.2 Total 14.5 0 Copyright 2013 Sigma Development Group, Inc. Page 7 of 12 0880(y lics Pipe Information Dashboard Hydrau REYNOLDS LOT 20 (Remote Area 2) From Elevi Pipe ID T Flows Inside Length ft 1 I C Value 'Total (Pt) psi ft Added GPM Diameter Fittings Fitting ft I Elev (Pe) psi Notes I To Elev2 Type in Friction Loss l Total Total ft] psi/ft Fnct (Pf) psi 22 466.38 4" Eddy Flow 101.2 4.3100 0 Len io.oT Ftg 0.0 C= 120 0.00466 Pt 23) 58.149 Pe 0.000 Pf 0.047 23 466.38 CM1 136.5 Total 10.0 Total Pressure at Node 22) 58.196 psi 82 467.21 2" Eddy Flow 2,2030 1 Len 0.8 Ftg 13.6 C= 120 0.01071 Pt 42) 56.801 Pe -0.359 Pf 0.155 42 466.38 RN 36.6 Total 14.5 62 467.21 2' Eddy Flow 2.2030 lIT Len 74.0 Ftg 27.3 C = 120 Pt 82) 56.596 Pe 0.000 Pt 1.085 82 467.21 BL 36.6 0.01071 Total 101.3 22 466.38 2" Eddy Flow 2.2030 1 Len 0.8 Ftg 13.6 = 120 Pt 62) 57.681 Pe 0.359 Pt 0.155 62 467.21 RN 36.6 0.01071 Total 14.5 21 466.38 4" Eddy Flow 136.5 4.3100 0 Len 10.0 Ftg 0.0 C = 120 0.00723 Pt 22) 58.196 Pe 0.000 Pt 0.072 22 466.38 CM1 173.0 Total 10.0 Total Pressure at Node 21) 58.268 psi 81 467.21 2" Eddy Flow 2.2030 T Len 0.8 Ftg 13.6 = 120 0.00795 Pt 41) 56.728 Pe -0.359 Pt 0.115 41 466.38 RN 31.1 Total 14.5 61 467.21 2" Eddy Flow 2.2030 lIT Len 137.5 Ftg 27.3 C = 120 0.00795 Pt 81) 56.484 Pe 0.000 Pt 1.310 81 467.21 BL 31.1 21 466.38 2" Eddy Flow 2.2030 T Len 0.8 Ftg 13.6 C= 120 0.00795 Pt 61) 57.793 Pe 0.359 Pt 0.115 61 467.21 RN 31.1 Total 14.5 20 466.38 4" Eddy Flow 173.0 4.3100 2E Len 90.0 Ftg 27.9 C = 120 0.00982 Pt 21) 58.268 Pe 0.000 Pt 1.158 21 466.38 CM1 204.2 Total 117.9 Total Pressure at Node 20) 59.426 psi 80 467.21 2" Eddy Flow 2.2030 1 Len 0.8 Ftg 13.6 C = 120 0.01443 Pt 40) 56.630 Pe -0.359 Pt 0.209 40 466.38 RN 43.0 Total 14.5 60 467.21 2" Eddy Flow 2.2030 TIT Len 137.5 Ftg 27.3 C = 120 0.01443 Pt 80) 56.479 We 0.000 Pt 2.378 80 467.21 BL 43.0 Total 164.8 © Copyright 2013 Sigma Development Group, Inc. Page 8 of 12 H88OO" Pipe Information REYNOLDS LOT 20 (Remote Area 2) From Elevi Pipe ID Flows Inside Length ft f C Value TTotal (Pt) psi Fitting ft Elev (Pe) psi ft Added GPM Diameter Fittings Notes To Elev2 Type In Friction Loss Total Total ft psi/ft Fnct (Pt) psi 20 466.38 2" Eddy Flow 2.2030 T Len 0.8 Ftg 13.6 c = 120 0.01443 Pt 60) 58.857 Pe 0.359 Pt 0.209 60 467.21 RN 43.0 Total 14.5 19 466.38 4" Eddy Flow 204.2 4.3100 0 Len 10.0 Ftg 0.0 C = 120 0.01398 Pt 20) 59.425 Pe 0.000 Pt 0.140 20 466.38F 66.38 CMI 1 247.1 Total 10.0 Total Pressure at Node 19) 59.565 psi 79 467.21 2" Eddy Flow 2.2030 T Len 0.8 Ftg 13.6 1 C = 120 f- 0.01587 J Pt 39) 56.490 Pe -0.359 Pt 0.230 39 466.38 RN 45.2 Total 14.5 59 467.21 2" Eddy Flow 2.2030 TIT Len 137.5 Ftg 27.3 C= 120 0.01587 Pt 79) 56.360 Pe 0.000 Pt 2.616 79 467.21 BL 45.2 Total 164.8 19 466.38 2' Eddy Flow 2.2030 1 Len 0.8 Ftg 13.6 c = 120 0.01587 Pt 59) 58.976 Pe 0.359 Pt 0.230 59 467.21 RN 45.2 Total 14.5 18 466.38 4" Eddy Flow 247.1 4.3100 0 Len 10.0 Ftg 0.0 C = 120 0.01908 Pt 19) 59.565 We 0.000 Pt 0.191 19 466.38 CMI 292.3 Total 10.0 Total Pressure at Node 18) 59.756 psi 78 467.21 2" Eddy Flow 2.2030 T Len 0.8 Ftg 13.6 C = 120 0.01784 Pt 38) 56.299 Pe -0.359 Pt 0.258 38 466.38 RN 48.2 Total 14.5 58 467.21 2" Eddy Flow 2.2030 111 Len 137.5 Ftg 27.3 C = 120 0.01784 Pt 78) 56.198 Pe 0.000 Pt 2.940 78 467.21 BL 48.2 Total 164.8 18 466.38 2" Eddy Flow 2.2030 1 Len 0.8 Ftg 13.6 C = 120 0.01784 Pt 58) 59.138 Pe 0.359 Pt 0.258 58 467.21 RN 48.2 Total 14.5 17 466.38 4" Eddy Flow 292.3 4.3100 0 Len 10.0 Ftg 0.0 C - 120 0.02530 Pt 18) 59.756 Pe 0.000 Pt 0.253 18 466.38 CMI 340.5 Total 10-0 1 Total Pressure at Node 17) 60.009 psi 77 467.21 2" Eddy Flow 2.2030 T Len 0.8 Ftg 136 [J 0.02046IPt Pt 37) 56.046 Pe -0.359 0.296 37 466.38 RN 51.9 Total 145 0 Copyright 2013 Sigma Development Group, Inc. Page 9 of 12 oo• Pipe Information REYNOLDS LOT 20 (Remote Area 2) From Elevi ft Pipe ID Flows Added GPM I Inside I Diameter in Fittings T Length ft J C Value Total (Pt) psi T Notes Fitting ft 1Total Elev (Pe) psi Frict (PQ psij To Elev2 Type Friction Loss psi/ft Total ft1 57 467.21 2" Eddy Flow 2.2030 TIT Len 137.5 Ftg 27.3 c = 120 0.02046 Pt 77) 55.983 Pe 0.000 Pt 3.371 77 467.21 BL 51.9 Total 164.8 17 466.38 2" Eddy Flow 2.2030 1 Len 0.8 Ftg 13.6 C= 120 0 02046 Pt 57) 59.353 Pe 0.359 Pt 0.296 57 467.21 RN 51.9 Total 14.5 16 466.38 4" Eddy Flow 340.5 4.3100 0 Len 10.0 Ftg 0.0 C = 120 Pt 17) 60.009 Pe 0.000 Pt 0.329 17 466.38 CMI 392.4 0.03289 Total 10.0 Total Pressure at Node 16) 60.338 psi 76 467.21 2" Eddy Flow 2.2030 1 Len 0.8 Ftg 13.6 C = 120 0.02385 Pt 36) 55.717 Pe -0.359 Pt 0.345 36 466.38 RN 56.4 Total 14.5 56 467.21 2" Eddy Flow 2.2030 lIT Len 137.5 Ftg 27.3 C = 120 0.02385 Pt 76) 55.703 Pe 0.000 Pf 3.930 76 467.21 BL 56.4 Total 164.8 16 466.38 2" Eddy Flow 2.2030 T Len 0.8 Ftg 13.6 C = 120 Pt 56) 59.633 Pe 0.359 Pt 0.345 56 467.21 RN 56.4 0.02385 Total 14.5 15 466.38 4" Eddy Flow 392.4 4.3100 0 Len 10.0 Ftg 0.0 C = 120 0.04217 Pt 16) 60.338 Pe 0.000 Pt 0.422 16 466.38 CMI 448.8 Total 10.0 Total Pressure at Node 15) 60.759 psi 75 467.21 2" Eddy Flow 2.2030 T Len 0.8 Ftg 13.6 C = 120 0.02821 Pt 35) 55.295 Pe -0.359 Pt 0.408 35 466.38 RN 61.7 Total 14.5 55 467.21 2" Eddy Flow 2.2030 TIT Len 137.5 Ftg 27.3 C = 120 0.02821 Pt 75) 55.344 Pe 0.000 Pt 4.648 75 467.21 BL 61.7 Total 164.8 15 466.38 2" Eddy Flow 2.2030 T Len 0.8 Ftg 13.6 C = 120 0.02821 Pt 55) 59.992 Pe 0.359 Pt 0.408 55 467.21 RN 61.7 14 466.38 4" Eddy Flow 448.8 4.3100 0 Len 10.0 Ftg 0.0 C = 120 0.05352 Pt 15) 60.759 Pe 0.000 Pt 0.535 15 466.38 CM1 510.5 Total 10.0 Total Pressure at Node 14) 61.294 psi © Copyright 2013 Sigma Development Group, Inc. Page 10 of 12 oo Pipe Information REYNOLDS LOT 20 (Remote Area 2) From Elevi Pipe ID Flows Inside Length ft c Value TTotal (Pt) psi Fitting ft I Elev (Pe) psi I ft Added GPM Diameter Fittings Notes To Elev2 Type In thtiOI1 Lost Total Total ft psi/ft Frict (Pf) psi 74 461.21 2" Eddy Flow 2.2030 T Len 0.8 Ftg 13.6 C= 120 0.03373 Pt) 54.760 Pe -0.359 Pt 0.488 34 466.38 RN 68.0 Total 14.5 54 467.21 2 Eddy Flow 2.2030 TIT Len 137.5 Ftg 27.3 C = 120 0.03373 3 Pt 74) 54.889 Pe 0.000 Pt 5.558 74 467.21 BL 68.0 14 466.38 2" Eddy Flow 2.2030 T Len 0.8 Ftg 13.6 c = 120 0.03373 Pt 54) 60.447 Pe 0.359 Pf 0.488 54 467.21 RN 68.0 Total 14.5 1 13 466.38 4" Eddy Flow 510.5 4.3100 0 Len 10.0 Ftg 0.0 C = 120 0.06744 Pt 14) 61.294 Pe 0.000 Pt 0.674 14 466.38 CM1 578.4 Total 10.0 Total Pressure at Node 13) 61.969 psi 73 467.21 2" Eddy Flow 2.2030 33 1 Len 0.8 Ftg 13.6 - C - 120 Pt 33) 54.086 Pe -0.359 0.589 33 466.38 RN 75.2 Total 14.5 53 467.21 2" Eddy Flow 2.2030 lIT Len 137.5 Ftg 27.3 c = 120 0.04069 Pt 73) 54.315 Pe 0.000 Pt 6.705 73 467.21 BL 75.2 Total 164.8 13 466.38 2" Eddy Flow 2.2030 T Len 0.8 Ftg 13.6 C = 120 0.04069 Pt 53) 61.020 Pe 0.359 Pt 0.589 53 467.21 RN 75.2 Total 14.5 12 466.38 4" Eddy Flow 578.4 4.3100 0 Len 10.0 Ftg 0.0 C = 120 0.08456 Pt 13) 61.969 Pe 0.000 Pt 0.846 13 466.38 CMI 653.7 Total 10.0 Total Pressure at Node 12) 62.814 psi 72 467.21 2" Eddy Flow 2.2030 1 Len 0.8 Ftg 136 j c = 120 0.04942 IPt 32) 53.240 Pe -0.359 Pf 0.715 32 466.38 RN 83.6 Total 14.5 52 467.21 2" Eddy Flow Len 137.5 C = 120 Pt 72) 53.595 2.2030 TIT Ftg 27.3 Pe 0.000 72 467.21 BL 83.6 Total j64.8 0.04942 Pt 8.144 12 466.38 2" Eddy Flow 2.2030 T Len 0.81 Ftg 13.6 C=120 l-I 0.049421Pf Pt 52) 61.739 Pe 0.359 0.715 52 467.21 RN 83.6 Total 14.5 0 Copyright 2013 Sigma Development Group, Inc. Page 11 of 12 08800 lics Pipe Information Dashboard Hydrau REYNOLDS LOT 20 (Remote Area 2) From Elevi ft Pipe ID Flows Added GPM I Inside I Diameter I in Fittings jLength 1t C Value J 1 Total (Pt) psiT Notes Fitting ft 1Total Elev (Pe) psi Frict (P0 psi1 To Elev2 Type Friction Loss psi/ft ] Total ft 6 466.38 4" Eddy Flow 653.7 4.3100 Len 5.0 Ftg 00 C= 120 0.10564 Pt 12) 62.814 Pe 0.000 Pt 0.528 12 466.38 CMI 737.2 Total 50 Total Pressure at Node 6) 63.342 psi 71 467.21 2" Eddy Flow 2.2030 T Len 0.8 Ftg 13.6 C = 120 0 .05497 Pt 31) 52.183 Pe -0.359 Pt 0.795 31 466.38 RN 88.5 Total 14.5 51 467.21 2" Eddy Flow 2.2030 TIT Len 137.5 Ftg 27.3 C= 120 0.05497 Pt 71) 52.619 Pe 0.000 Pt 9.058 71 467.21 BL 88.5 11 466.38 2" Eddy Flow 2.2030 1 Len 0.8 Ftg 13.6 C = 120 0.05497 Pt 51) 61.677 Pe 0.359 Pt 0.795 51 467.21 RN 88.5 Total 14.5 6 466.38 4" Eddy Flow 634.5 4.3100 0 Len 5.0 Ftg 0.0 C = 120 0.10190 Pt 11) 62.832 Pe 0.000 Pt 0.510 11 466.38 CMI 723.0 Total 5.0 5 466.38 6" Sch 10 737.2 6.3570 T Len 16.8 Ftg 37.7 C = 120 0.05637 Pt 6) 63.342 Pe 0.000 Pt 3.070 6 466.38 FM 1,460.3 Total 54.5 4 436.13 6" Sch 10 6.3570 E Len 30.3 Ftg 17.6 C = 120 0.05637 Pt 5) 66.412 Pe 13.098 Pt 2.697 5 466.38 FR 1,460.3 Total 47.9 2 436.13 8" DI 8.4500 E Len 5.0 Ftg 31.6 C = 140 0.01060 Pt 4) 82.217 Pe 0.000 Pt 0.388 4 436.13 UN 1,460.3 Total 36.6 1 436.13 8 PVC CL200 250.0 7.6800 T,CViGV Len 70.0 Ftg 150.3 C = 150 Pt 2) 82.605 Pe 0.000 Pt 4.383 2 436.13 UN 1,710.3 0.01990 Total 220.3 0 420.00 8" PVC CL200 7.6800 GVI2EE Len 250.0 Ftg 71.4 C 150 0.01990 Pt 1) 86.988 Pe 6.984 Pt 6.395 7 psi loss for DCDA shown as elevation 1 436.13 UN 1,710.3 Total 321.4 Total Pressure at Node 0)100.367 psi 0 Copyright 2013 Sigma Development Group, Inc. Page 12 of 12 c2-o( -o4 r*--1,A7ERl.,AL [DA7A 3UBM177AL REYNOLDS LOT 20 GARLSAD, CA EPI C FIRE PROTECTION, INC. 705 TURTLE POINT WAY SAN hIARCOS, CA 32000 (760)310-6122 FAX(70)798-055 Page 1 sf6 Page 20(6 NIKING 0 ESFR PENDENT SPRINKLER VKS1O (1(25.2). The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvlkIngcorpcom Visit the Viking webslfe for the latest edition of this technical data page: www.vUdnggroopinc.com 1. DESCRIPTION Viking Early Suppression Fast Response (ESFl) Pendent Sprinid, VK510 Inoxpo-rates the capability to suppress specific high-dtallenge tires. The addition of a larger K-Factor allows ESFR performance at lower end-head pressures than-ESFR 1<14 Sprinklers. 1<252 ESFR sprtnldedi can: - Eliminate the m-rackSprinklers when protecting high-plled.storagestfomta.r specified materials irlo to 40 it: (12.2 m) with ceilings up to 45 It (13.7 m)........ Reduce or eliminate the need for a system tire pump. Provide ttexikllitywtren sizing system piping. VI king VK510 ESFR Pendent Sprinklers are primarily intended to protect the following types of storage, which tend to produce Se Me-challenge tires: paflettzed and solid pile storage and single, double, multiple row, and portable open rack storage (no open-top containers or solid shelves). Viking ESFR Pendent VK510 Sprinklers provide protection of most common storage materials. Including. - Encapsulated or Unencapsulated Class I, II. lit, and IV commodities - cULus listed for protection of car-toned unexpanded plastic commodities and FM Approved for protection of carter-red and uncartoned unexpanded plastic commodities. - FM Approved for protection of exposed expanded potyryrme and panded polyurethane commodities. Refer the Approval Charts and Design Criteria for stiles tiding and FM Approval requirements that must be followed. In addition, some storage arrangements of roped papet flammable liquids, aerosols. and rubber tires may be Protected by Viking ESFR Pendent Sprinkler VK510. 2. LISTINGS AND APPROVALS cULus listed: Category VNWH (Listed as a Specific Application ESFR Sprinkler) Successfully meets new UL 1767 test standard and compliance program for ESFR sprinklers Installed In-rack storage with high clearances to ceiling (20 ft or greater) PM Approved: Citrus 2026 VdS Approved Certlticate G4040015 LPCB Approved: Ret No. 096e/07 ® -Approved: Approved by the China Certification Center for Fire Products (CCCF) The 10280 '11<510, ESFR Pendent Sprinkler Assembly conforms to the provision of CtiAP11.03/03 standard. CUAP11.03/03 approvals are provided by FM Approvals Ltd. I Windsor Dials Windsor. Berkshire, UK. SL4 1 RS Approval Certificate No. Issued December 20. 2010. Note: Other International approval certificates are available upon request Refer to Approval Chart 1 and Design Criteria for cliLus Listing requirements, and refer to Approval Chart 2 and Design Criteria for FM Approval requirements that must be followed. The Viking Corporation, 210 N Industrial Part Drive, Hastittgs MI 49058 Telephone: 269-945-9501 Technical Services: 877384L5464 Fax: 269-818-1680 Email: techsvcs@vildngcorp.ciam visit the Viking website for the latest edition of this technical data pagat www.vlklnggroupinc.com TECHNICAL DATA . . Sjiedflcadons.' . . Minimum Operating Pressure: Refer to NFPA 13orFM Global Loss Proven-lion Data Sheets. Marrimien Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (345 bar). Thread size: 1. NPT for Sprinkler 12080.25mm BSP for Sprinkler 12200 ... Nninal K-Factor: 252 U.S.(363 metric-).....................- - - MetrIc K-hmeasranrnent shown is in bar. When pressure is ereaso-edin kPa, divide the metric K-faster slrowirby 10.0. Overall Length: 3-3/16 (81 mm) Deflector Diameter ..(44.5 mm) Covered by one ermwe of the blowing patens: USS,829,5St tJS6059.044; US5,336.509: 11S6,5t1Z643: US 868,917;Atr722593t GB23367?7 Material Standards: . . Frame Castlng Brass UNS-C84400 . Deflector. Phosphor Bronze UNS-051000 Seat Copper UNS-C11000 and Slainleits Steel UNS-530400 Belteelte Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Compression saew:Stalnless Steel UNS-531603 Trigger and Supped: Stainless Steel UN5-S31600 Fusible Element Assembty. Beryllium Nickel, coaled With Mad: acrylic paint Ordering InformatIon: (Also refer to the owent Viking puce list) Order ESFR Pendent Sprinkler VKSIO by first adding the appropriatesuffix for the sprrnlder finish and then the appropriate suffix for the temperature rating to sprinkler base part number Frond, Stills: Brass = A Temperature Suffix 16F(74C)rC2O5.lr(%C),E For example. Sprinkler 111<510 with 1 NPT threads, Brass finish, and 165 F (74 C) temperature rating = Part No. 12080AC. AvaIlable Finishes And Temperature Ratings: Refer to Tattle 1. Accessories: (Also refer to the Viking websita) Sprinkler Wrenches: A Part No. 1363511118 (double-ended wrench - Use Side B. Side A is for use with 1<14.0 ESFR Pendent Sprinkler 111(500) Available since 2006. - B. Pais 1,1012143WJB (no longer available) Sprinkler Cabinet Six-tread capac11y. Part No. 01731A (available since 1971) Viking sprinklers are manufactured and tested to meet rigid requirements-of the approving agencies. The sprinklers are designed to be installed in accordance with recognized installation standards or FM Global Loss Prevention Data Sheets. System design must be based on ESFR design guidelines described In the latest edition of the appltdablo FM - Global Loss Prevention Data Sheets, the latest NEPA Standards, the latest standards of Verband dot' Sachverslcberer (VdS), Loss Prevention Council (LPCB), the Authorities Having Jurisdiction, and also with the provisions of govern- mental codes, ordinances, and standards whenever applicable. Deviation from the standards or any alteration to the Sprinkler after It leaves the factory Including, but not limIted to: painting, plating, coating, or modificatIon, may render the sprinkler inoperative and will automatically nullify tho approval and any guarantee made by The Viking Corporation. pnntiers must be handled with care. They must be stored tea cod, dry place in their original shipping container. Never install Sprinklers that have been dropped or damaged In any way. Such Sprinklers should be destroyed immediately. NOTE: Wet pipe Systems must be provided with adequate heat The sprinklers must be installed aftertite piping is in place to prevent mechanical damage. Before installing, be sure to have the appropriate sprinkler model and style, with the correct orifice size, temperature rating, and response characteristics. - With the sprinkler contained in the plastic protective cap, apply a small amount of pipe-joint compound or tape to the male threads only, white taking care not to atom a build-Up of compound in the riprinkier-orifice. Use ONLY sprinkler wrench I0285WIB or 13655W/B (shown In Figure 1) thor Installing ESFR Sprler6derVK510t With the sprinkler contained in the protective cap, Install the sprinkler onto the •plplrrg by applying the sprinkler wrench to the Sprinkler wrench flats only, white taking care not to damage the sprinkler operating parts. Form No. F_100102 1e.06.30 Rev 16I Replaces Form No. F_100102 Rev. 15.1 Foes No. F_100102 16.06.30 Rev 16.1 (Updated formatting: Added CCCF approval) Page 3 of 6 S1NkLERVK510((25i)] The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: teclasvcs@vlklngcorp.com Visit the Viking webshe for the latest edition of this technical data page: wwvIkInggroupinc.com - 00 NOT use any other type of wrench, as this could damage the unit. - DO NOT use the sprinkler deflector or firsthte element to start or thread the sprinkler into a fitting. DO NOT exceed 50 It its of torque (hand tight plus approximately two fail turner with the wrench) to install these sprinklers. Higher levels of torque may distort the sprinkler inlet with consequent leakage or impairment of the sprinider. E aIlatIOnt the entire sprinkler System must be tested. The test must be conducted to comply with the installation Standards. Make sure thespdekler has been-prepedytightened- ifa thread leak occurs. normally the unit esant be rembved, new pipeloint compound or tape applied. and then reinstalled. This IS due to the fact that when the joint seal is damaged, the sealing compound or tape is washed out of the joint Immediately replace any damaged writs, using thespecial sprinkler wrench only. F. After Installation and testing and repairing of all leaks, remove the protective caps from the sprinklers. Do NOT use any type of tool to remove the cap. Remove the cap by hand: turn It slightly and pull It off the sprinkler- When remov- ing caps, use care to prevent dislodging or damaging sprinkler fusible element THE CAPS MUST BE REMOVED FROM SPRINKLERS BEFORE PLACING THE SYSTEM IN SERVICE] 5. OPERATION During fire conditions. the heat-riensith e.&rslbte element assembly disengages. releasing the seat and believitte spring assembly to open the waterway. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to suppress the tIre. 6. INSPECTIONS. TESTS AND MAINTENANCE The owner Is responsible for maintaining the fire protection system and devices In proper operating condition. For minimum maintenance and inspection requirements, refer to the NFPA standard that describes care and maintenance at sprinkler systems. in addition, the Authorities Having Jurisdiction may have additional maintenance, testing, and Inspection requirements that roust be followed. - The sprinklers must be inspected on a regular basis for corrosion. mecbarricai damage, obstructions, paint, etc. The frequency of inspections may vary due to corrosive atmosphere, water supptes, and activity around the device. Sprinklers that have been painted or mechanically damaged must be replaced Immediately. Sprinklers showing signs of corrosion shall be tested and/or replaced immediately as required. Installation standards require sprinklers to be tested arid, if necessarfr replaced after a-specified term of service. For Viking ESFR Pendent Sprinklers, refer to the Installation Standards (e.g., NFPA 25) and theAnthorities Having Jurisdititral for the specified period of time after which testing and/or replacement-is required. Sprinklers that have operated cannot be reassembled or reused, but must be replaced. When replacing sprinklers, use only new sprinklers. The sprinkler disdiarge pattern is critical for proper lire protection Therefore, nothing should be hung from, attached to, or other. wise obstruct the discharge pattern. All obstructions must be immediately removed or. if necessur additional sprinklers installed. 0. When replacing existing sprinklers, the system must be removed from service. Refer to the appropriate system description and/ or valve instructions. Prior to removing the system from service, notify all Authorities Having Jwisdk2ioni. Consideration should be given to employment of a lire patrol in the affected area, - - - Remove the system from service, drain all water, and relieve at pressure on the piping. Listing the special.sprinkler wrench, remove the old sprinkler and install the new unit Care must be taken to ensure that the replacement sprinkler is the proper model and style, with the correct orifice size, temperature rating, and response character-istics. Afrifly stocked spare sprinkler cabinet should be provided for this purpose. Place the system bark in service and secure all valves. Check the replaced sprinklers and repair at teaks. E. Sprinkler systems that have been subject -to a lire must be returned to service as soon as possible. The entire system must be inspected for damage and repaired or replaced as necessary. Sprinklers that have been exposed to corrosive products of combustion, but have not operated. should be replaced. Refer to the Authorities Having Jurisdiction for minimum replacement requirements. - AVAILABILITY - The Viking Model VKSIO Sprinkler is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to tithing's current list price schedule or contact Vetog directly. The Viking Corporation, 210 N Industrial Parlcl)nve, Hastings MI 49058 Telephone: 269-945-9501 Technical ServIces: 877-384-5464 -Fax: 269-818-1680 Email: tecthSvcs@vlkingcorp.com Visit the Viking webstte for the latest edition of this technical data page: wwwtilklnggroupinc.com - TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES .... r '---. in -a--.- I •JDi.irar- - lsr- -- 1i r Wrench Fiat - - Protective Sprinkler Cap Use Side B co,-......, - ESFR Pendent K5.2 - Sprinkler VK5I0 Figure 1: - ESFR Pendent Sprinkler Wrench 13e35WI3 ?; (Dinmmensions nm-'e 4 - appmoxirmate.) I- (45 'mm) - - - - F'r9ure2 - ESFR Pendent Sprinkler VK510 Ouneeexlorrs Form No. F_100102 16.05.30 Rev 16.1 I Form No. F_100102 16.06.30 Rev 16.1 Page 5 of 6 'II ESFR PENDENT I Ii(II4I 1 SPRINKLER VK510 (1(252) The Viking Corporation, 210 N Industrial Pant Drive, Hastings MI 49058 Telephone: 269-845-9501 Technical Services: 871-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorpcom Visit the Viking website for the latest edition of this technical data page: www.vlkinggroupincatom Listings and Approvatsm Nominal K- Overall Factor. Length -- SIN. N Size. U.S. metrIc' Inches mm duos' NYC VdS LPCB (( ® 12080 VK510 V NPT 26.2 363 3-3/16 81 Al So,rnsovA. Al Al - - 12200 VK510 25mm 8SF 252 363 3-3/16 81 Al S,nFns*1n5 Al Al - - 19857 VK510 20313 VK510 25mm 6SF 252 1 363 3-3/16 81 - . - - - - . 61 Approved Temperature Ratings Aped FinishA-l65F(74'C)aed5F(96C) 8-166'F(74C) . . Brass Footnotes Base part number shorn,,. For complete part nan,b0e refer to the price list. Thisthatshowsbstingsand approvals available at the lme of printing. 01-.nr opp•5 1,0 krpr,--- Metric 1<-Factor nreawneormrt shoe,,, is when premors is measured in ban When pressure is n,eeer,,ed in IrPa. divide the metric K-Factor shown b:10, Refer to the latenttrndarsts of NFPA 13. LPCB lom Plevenkon Standaids. and the late,tVdS standards.listed by Undevaters Laboratories lee mi main the u.s. and Canada as a Spevitc Apptieatlon ESFR Sprinkler (refer in the detector reqrremnetrts on page 4). Meets New Verb Ctlyrnqrrirerneets. effective July 1.2008. ESFR Pendent Sprirrlder VXSIO is ditars Listed as indicated in Approval Chart I for ivslola6onin accordance with the latest appropriate NFFAstan-ddvds (irtiradieg NFFo, 13) for ESFR Pendent 1(20.2(363) Sprinlders. for. Protecting rack Storage of ordain specilied materials up to 408(122w) high in buildings with 460(13.7w) high endings with NO in-rod, sprinldea. - &rep(iorr-lo IfFPA 13 sprdrtklerhwtailat/orr roles for ESFR Pendent K25.2 Sprlrrldarsr djten Lintleg Requirement for Buildings up to 40 & (12.2 m) High, Locate the do0cct between 6and 18(152 and 457 non) below the railing. clJLrrs Listing Reqoirement for Buildings Between 40 it (12.2 os) and 456. (13.7m) High: Locate the dotoctor between 6and 14 (153 and 356 mm) belnw the ceiling. - The minimum area of coverage allowed per sprinkler in 64 It' (5.8 m') per NFPA 13. Ilaninoant Roof or Coiling Slope: 2 in 12 (167 etnfm or 9.5 degrees). Sprinkler Position: Approved for use only in the Pendent position. Align the deflector parallel with the ceting or roof. Systen,l\jpw: Wet systems only. Deflector Distance from Walls: At least 4 (102 mnr) from walls, and no more than one-half the allowable distance permitted between sprinklers. Clearance from Deflector to Top of Storage: At least 36 (914 mm). Maximum Distance Between Sprinklers: The nra,irrncn area of coverage atoned per sprinkleris ito fl (93 ma) - For buildings over 30 0(9.1 m) high. sparIng between sprinklers and/or brands lines must befrw,, 810106(2.4103.1 w). For building heights op to 308(9.1 m). the spacing atoned between sprinklers add/or branch lines is to 128 (2.4 103.7 to). provided the area covered per sprinkler does not exceed the ma,0mwn 1011 It' (93 ma) atowed. Refer to the Instaliaton Standards for permIssIble deviations from the ma,dvnum sprinkler spacing wins above, to.eliedeate obstructions created by bosses and bar joists when using ESFR sprinklers. Note: If the ceiling Is bras and girder or panel construction locate sprinklers In the bays rather than under the beams. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling ofSpnnklers. Viking ESER Pendent Sprinklers are to be installed in accordance with the latest edition of Viking technical data, the latest standards of NFPA, VdS, LPCB, and any other Authorities Having Jurisdiction, and also with provisions of governmental codes, ordinances, and standards whenever applicable. Form No. F_100102 16.06.30 Rev 16.1 11(1 Pi p ® IlI'7M SPRI ESFR PENDENT NKLER VK510 (K25-2) The Viking Corporation, 210 N Industrial Park DrIveHastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax-269-818-1680 Email: techsvcsivikingcorpcom Visit the Viking webslte for the latest edition of this technical data page: www.nilcinggroupinc.com Base me Part r Nominal K-Factor Overall Length -SlNThread Size 12060 VK510 I' NPT 252 W~ 3-3116 81 Al 12200 VK510 25 nun 6SF 1 25.2 363 3-3/16 81 . Al Approved Temperature Ratings Approved Finish A165nF(74C)an4205vF(96C) • . 1-Brass Footnotes Base part numbersfrow,r. For complete part number. refer to the price list Metric K-Factor r,reisrrrnnmot strosori isoIree prrre is measured in ban When pressure is measured in kPa, diode the metric K-Factor strown by 10.0. This chart shows the F14 Approvals available at the time of printing. Other approvals may be in process. 'FM Approved as a.quidr response pendent Non-Storage sprinkler and also FM Approved an a quick rospawe pendent Storage sprinkler. Refer to Design Cndrnin below - FM Aver-oval Reonlremeels: Sprinkler VK510 is FM Approved as a quids response pondont Storage sprinkler as indicated in the FM Approval Guide. for specific application and irrstatation wqsirernerris, reference the latest applicable FM Loss Prevention Data Streets (including 0019 Streets 20 and 8-9). Sprink/er VK510 is also FM Approved as a quick response Pendent Non-Storage sprnideras indicated in tlreFkt Approval Guide. - For specific application and instatatios vequirerner4s. refarnnoe the latest applicable FM Loss Prevention Data Sheets (aldoderg Data Sheet 2-0)- FM Global Loss Prevention Data Sheets contain guidelines relating to. but not tlmtnd to: minimum water supply reqrairernerrts. hydraulic design, coiling slope and obstructions, nrirrirrncm and rna,dn,on, otooratrlespacing. arsdde8octor distance below the nailing. Note: The FM Installation guidelines may differ from clilirs and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F091699 -Care and Handling of Sprinklers. Viking ESFR Pendent Sprinklers are to be installed in accordance with the latest edition of Viking technical data, the latest applicable FM Global Loss Prevention Data Sheets, including 2-0 and 8-9, applicable standards of NFPA, and any other Authorities Having Jurisdiction, and also with provisions of governmental codes, ordinances, and standards whenever applicable. Form No. F_100102 15.06.30 Rev 15.1 Replaces Form No. F..100102 Rev. 15.1 (Updated ANSI WARNING and NOTICE formatting: Added CCCF approval) Page 1 of MICROFAST' QUICK l$IIIUI7Ws RESPONSE UPRIGHT SPRINKLER VK300 (1(5.6) Page 2 of 4 The Viking Corporation, 210 N Industrial Park Drive, Hastings 111 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-8184680 Email: techsvcxvIklngcorp.com Visit the Viking website for the latest edition of this technical data page: www.vIklnggroupinc.com OPERATION During fire conditions, the heat-sensitive liquid In the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking MtcrofaO Quick Response Upright Sprinkler VK300 is available through a network of domestic and International distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE AVAILABLE SPRINKLER pTEMPERATURE c49lll[eWalil,I2lllEt:l* - S4án1IiaI '4 jspergtutiflng = aip*td're . . Ordinary 135'F (57'C) 100 'F(3a'C) Orange Ordinary 155 ¶(68'C) 100'F(38'C) Red Intermediate - 175 F (79 'C) 150 'F (55 'C) Yetiew Intermediate 200 'F (93 'C) 150 'F (65 'C) Green High 286 'P(141 'C) 225 'F (107 'C) Blue Sprinkler Finishes: Brass, Chrome. While Polyester, Block Polyester. and ENT Ce.noalen.Reslslant Cuetlegef' White Polyester, Black Polyester, and Black FIFE. ENT In at temperature ratings except 135 'F (57 'C) Footnotes The sprinkler temperature rating is stamped on the deflector. Based on NFPA-13. Other tints may apply, depending on lire loading. sprinkler location, and ether requirements of the Authority Having Jurisdiction. Refer to specific Installation standards. iThe corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated In the Approval Charts. These rents cannot and do not represent an possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat- ible with or suitable for the proposed ennimement For automatic sprinklers, the coatings indicated am applied to the exposed exterior surfaces only. Note that the spring Is exposed on sprinklers with Polyester, ENT, and PTFE coatings. For ENT coated aurornutc sprinklers, the waterway Is coated. Protective Sprinkler Cap._____T""1 Wrench Flat Figure 1: Standard Sprinkler Wrench 21475Mm Form No. F052114 17.10.05 Rev 17.1 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269.818-1680 Email: techsvca@vlklngcorp.com Visit the Viking webslte for the latest edition of this technical data page: www.vlklnggroupInc.com DESCRIPTION The Viking Mlcrofast Quick Response Upright Sprinkler VK300 Is a small, ttrermosensitive, glass-bulb spray sprinkler available in several differ- ent finishes and temperature ratings to meet design requirements. The spe- cial Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coat- ings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as Indicated in the Approval Charts. (Note: FM global approves the ENT coating as corrosion resistant FM Global has no approval classification Polyester coatings as corrosion resistant) LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Classes 2002 and 2020 Refer to Approval Charts and Design Criteria for listing and approval requirements that must be followed. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar)' Maximum Working Pressure: 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: liSA Patent No. 4,831,870 Thread size: 1/2' NPT, 15 mm BSP Nominal K-Factor. 5.6 U.S. (80.6 metric') Glass-bulb fluid temperature rated to -65 F (-55 'C) Overall Length: 2-3/16' (56 mm) clitss Listing, FM Approval, and NFPA 13 Installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CS Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector. Brass UNS-C23000 or Copper UNS-C19500 Bulb: Glass. nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PIPE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 For Polyester Coated Sprinklers, Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT plated Ordering Information: (Also refer to the current Viking price list) Order Viking MIcrofast5 Quick Response Upright Sprinkler VK300 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating lathe sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN Temperature Suffix (FrC): 135/57' =A, 156'/68= B, 175I79 = 0, 200/93 = E, and 286'/141 G For example, sprinkler VK300 with a 1/2 NPT thread, Brass finish and a 155 'F/68 C temperature rating = Part No. 12978A8 Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer lathe Viking website.) Sprinkler Wrench: Standard Wrench: Part No. 21475M/B (available since 2017) Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. Form No. F_052114 17.10,05 Rev 171 Replaces Ferns No. F .2 _052114 Rev 15 (Replaced wrench 10896W/B with 21475M/B) Page 3 of 4 MICROFAST5 QUICK \I 11(1 I"lGiMoo[ SPRINKLER RESPONSE UPRIGHT VK300 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcstvlkingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vIklnggroupinc.com '- Base Part 08N Thread Size Nominal K-Factor Overall Length Listings and Approvals' Number' NPT BSP U.S. metric' j inches mIre cUlus VdS LPCB NYC' I CE 12978 VK300 1/2" 15mm 5.6 80.6 2-3/16 Al, B2 — — See lnntrvrte 7. — '' 06661B I VK300 I 1/2' 115min 714786. — — ISeefootnote7. - Approved Temperature Ratings 1 5.6 I 80.6 1 2-3/16F ENTa A - 135°F (57 'C), 155 'F (68 'C). 175 'F (79 'C), 200 'F (93 'C). and White Approved Finishes Polyeslerm, and Black Potyester5a B -155 'F (68 C 175 'F (79 'C), 200 'F (93 'C). and 286 'F (141'C) Footnotes 'Base part rronrber Is shore,. For 000pinte part number, refer to V5dm5s current price schedule. 'Metric k.foctre measurement sh,cn Soiree pressure is measured hr Boy When nesermo is n,00rumnd in We, didde the rrreblc M-clorshcon by isa This rose shoes the ratings and eppmcele avetable at the time of rainting. Check with the manufacturer for any additional epprusets. 'Listed by Undere,ltes Laboratories Ins. fares In the U.S. and Canada 'Otter rehoS one available on request nclh the same Listings ,mrditppme,ets as the standard mires. CtILO5 Listed as corres.en resistant Meets New YamS City mquhorvevtu, ettostlee July 1, 2008 'Aenepted for use. City ,f New YeA Oared or Standards and Appeals, Calendar Number 219-76.55 and City Or New Yed, Deparbs,et at Buildings. MEAOS-52.E. bAt re. - - . '"d"PSfGN CRITERIA IJL' -. '1 fAfi53 n.'fer 13'Attpro'.o'Cfleff I °'°'•l sUture Listino R000frements: The Viking Mtuofest' Quick Response Upright Spookier VK300 is ctJLus Listed as Indicated in Approval Chart ito, installation at accordance with the latest edition of NFPA 13 for standard spray sprinklers. 'Designed for use in Light and Ordinary Hazard occupancies. The sprinter installation rules contained in NFPA 13 for standard spray uptight sprinklers must be followed. IMPORTANT: Always cefer to Bulletin Fotcri No, P091699 I Ca10 and Handling of Spilrtklers. AlSO toter no porm i No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Page 4 of 4 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877484-5464 Fax 269.8184680 Email: techsvcs@vlkingcorp.com Visit the Viking website for the latest edition of this technical data page: www.viklnggrouptnc.com Base Part Thread Sim Nominal K-Factor Overall Length FM Approvalas Number' SIN also (Refer to Design Criteria below.) NPT BSP I U.S. I metrici inches mm 2,V16 56 Al. B2 NOTICE, Piodual Below Limited Availabil.ify (Contact Local Whing Office) Approved Temperature Ratings Approved Finishes A. 135 'F (57 'C), 155 'F (68 'C), 175 'F (79 'C), 200 'F (93 'C), and 286 'F (141'C) 1 - Brass. Chrome, White Polyestert. and Black 8-155 'F (68 'C), 175 'F (79 'C), 200 'F (93 'C), and 286 'F (141'C) 2- EN1° Footnotes 'Base part number is shown. For complete part number, refer to Miring's current price schedule. 'Metric K4act0rrneasromm,evt shown is when pressure is measured In Bar. When ptnssure is measured in ld°a, rBuidn the metric K4oclOr shown by 10.0. 'This table shows the FM Approvals available at the time Of printing. Check with the manufacturer for any additional approvals. 'Other colors are available on request with the same Approvals as the standard colors. 'FM approved as corrosion resistant 'rb,.......................... '. .Aw ' . . . - . . . (fasofie(efloApprgvatQraft .." - FM Aesrovat Reoulrm,wnte: The Mteofaof Quick Response Upright Sprinkler VK300 is FM Approved as a quick response Non-Storage upright sprinkler as indicated in the FM Approval Guide. For specific application and Installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Preverrtke, Data Sheets contain guidelines relating to, but not Smiled to: minimum water supply requirements. hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing. and deflector distance below the ceding. NOTE, The FM installation guidelines may differ from cUL,rs and/or NFPA criteria, IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No, F_080614 for genoral care, Installation, and maintenance information. Viking oprinklera are to be metalled In accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable, Form No. F_052114 17.10.05 Rev 17.1 Form No. F052114 17.10.05 Rev 17.1 Replaces Form No. F_052114 Rev 15.2 - (Replaced wrench 10896W/B with 21475M18) Page lot 6 STANDARD/QUICK RESPONSE 'JII(JI416 EXTENDED COVERAGE PENDENT SPRINKLER VK534 (K11.2) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com DESCRIPTION Viking EC/OREC Pendent Sprinkler VK534 is a thermosensitive spray sprinkler available in several different finishes and temperature ratings to meet varying design requirements. The extra-large orifice produces the flows required to meet Light and Ordinary Hazard density re- quirements at lower pressures than standard orifice or large orifice sprinklers. The glass bulb operating element and special deflector characteristics meet the challenges of quick response extended coverage standards. Pendent Sprinkler VK534 is cULus Listed as standard and quick response. The special Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, ENT coating has been investigated for installation in corrosive atmospheres. See Approval Charts. LISTINGS AND APPROVALS cULus Listed: Category VNIV Refer to Approval Chart 1 and Design Criteria cULus Listing requirements. NOTE: As or May 2018.11 logos has. ba.i, 1.- mossdfrwn no smash boa.. TECHNICAL DATA Specifications: Minimum Operating Pressure: Refer to the Approval Charts. Maximum Working Pressure: 175 psi (12 Bar). Factory tested hydrostatically to 500 psi (34.5 bar). Factory tested hydrostatically to 500 psi (34.5 bar). Thread size: 314 (20 mm) NPT Nominal K-Factor 11.2 U.S. (161.3 mettict) t Metric K-factor measurement shown is in Bar. When pressure is measured in liPa, divide the metric K-factor sheen by 10.0. Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-3/87(61 mm) Material Standards: Sprinkler Frame: Brass UNS-C84400 Deflector Brass UNS-C26000 Bulb: Glass, nominal 3 m diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and insert Assembly: Copper UNS-C1I000 and Stainless Sleet UNS-530400 For Polyester Coaled Sorinklers: Belleville Spring-Exposed For ENT Coated Sorinkler Belleville Spring-Exposed, Screw and Pipcap-ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Viking EC/QREC Pendent Sprinkler VK534 by first adding the appropriate suffix for the sprinkler finish and then the appro- priate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-1W, Black Polyester = M-/B, and ENT = JN Temperature Sutti,c 135°F (57 °C) = A, 155°F (68 'C) = B, 175°F (79 °C) = 0,200 °F (93 °C) = B, and 286 °F (141 °C) = 0 For example, sprinkler VK534 with a Brass finish and a 155 'F (68 °C) temperature rating = Part No. 08340AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website) Sprinkler Wrenches: Standard Wrench: Part No. 05118CW/B (available since 1981) Wrench for recessed pendent sprinkler Part No. 11663W/B" (available since 2001) "A '4' ratchet is required loot available from Viking). Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) Page 2 of 6 STANDARD/QUICK RESPONSE I S4J EXTENDED COVERAGE Fttt® TECHNICAL DATA I(J PENDENT SPRINKLER VK534 (KII.2) The Viking Corporation, 210 N industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@viklngcorp.com Visit the Viking website for the latest edition of this technical data page wwwvikloggroupinc.com OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and seating spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for inspection, Testing and Maintenance requirements. AVAILABILITY Viking EC/QREC Pendent Sprinkler VK534 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Protective Sprinkler Clip Figure 1: Standard Sprinkler Wrench 051I8CWIB 4. INSTALLATION Refer to appropriate NFPA Installation Standards. Form No. F_051393 18.08.23X Rev 18.2 Replaces Form F051393 Rev 18.1 Form No. F_051393 18.08.23X Rev 18.2 (Revised ordering information.) Page 3 of 6 STANDARD/QUICK RESPONSE \J EXTENDED COVERAGE I Kjm PENDENT SPRINKLER VK534 (KII.2) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Vikinq website for the latest edition of this technical data eane www.vikinaarouojnc.com TABLE 1: nklrimniltrru.p AVAILABLE SPRINKLER TEMPERATVRE RATINGS AND FIN15HES kNo,ktai 'CIasod1ssrl6I '"' 1.P1ompeitature flatlng - ClILnj'eirip. Lu - Ordinary 135 'F (57 'C) 100 'F (38 'C) Orange Ordinary 155 'F (68 'C) 100 'F (38 'C) Red intermediate 175 'F (79 'C) 150 'F (65 'C) Yellow Intermediate 200 'F (93 'C) 150 'F (65 'C) Green High 286 'F (141 'C) 225 'F (107 'C) Blue Sprinkler Finishes: Brass, Chrome, White Polyeslere, Black Polyester', and ENT Corrosion-Resistant Coatings': ENT Footnotes The sprinkler temperature rating is stamped on the deflector. 'Based on NF'PA-13. Other limits may apr'y, depending on Ore loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. I For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester coatings. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Chart. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings ate cornpat- hI,, with or suitable for Ore proposed environment. For ENT sprinklers. all exposed surfaces and the waterway ore coated, bat note that the spring is exposed. Stop l: Carefully slide the wrench sideways around the deflector, ensuring en- gagement With the sprinkler wrench flats.-- Pendent Sprinkler Sprinkler wrench 13577W/B" must be used for installing wax coated sprinklers. "A 112" ratchet is required Step 2: Carefully press the wrench upward and (not available from Viking) ensure engagement with the sprinkler wrench flats. Figure 2: Wrench 11663W/B for Recessed Pendent Sprinkler VK534 orm ISO. t_UD1,cs,t in.lJ0.ZJA rcev ln.4 Page 4 of 6 STANDARD/QUICK RESPONSE EXTENDED COVERAGE S4JII(JNIGj :I IEq1 .y iy PENDENT SPRINKLER VK534 (KII,2) I The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 817-384-5464 Fax: 269-8184680 Email: techsvcs@vikingcorp,com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com ,- Sthr t Spdnktur Bane N Thread She Noteteat K-Facto, Maciwo,. Wot.e Overall L,ngth Part Noe,bo,' SIN IncIte, no, Working P,0000re US. fl,etelc' led,,. man 08340 Pendant VK534 314 20 11.2 1 1613 175 psi (12 Bar) 2-5116 J 59 Minimum Water Supply R.q,d,o,00r,to' Lioth go Ares' Mao. Spdntder Manhour, (Radar also to UL Design SP.Ing Are. par Criteria) Light Retard ordinary Nra,d Group I O,dteorn Record Group 8 Flow I Prosoor. Fl- I Pre000ro Flow) Prooeero OULuO' Standard Response 16110161t(4.9 2565'(23.8 - 388pn11911.5psi 51op0©28.7p5i Clx 017 020 C2W en 4.90) n'( 1143.91/ninth .79 earl (193.1 1/ion @1.43 Be,) 1811. n ft it. (5.5 324111(30.1 - 49 gpo @19.1 psi 65 SpIn 19 ° ' - cix 017 020 C2W -5.5.)Itt') 1185.51/440191.32Bar( (246.1 Unrin®2i2Bar) 2o it. n2ott.(6.1 40051(37.2 - tx go. (928.7ps1 otgprnc9sl.opni CIX n, 06.10) 5') (227.1 1/ton @1.90 Be,) 1302.0 1/non 193.52 Burl Quick Response 1211.n 1211.(3.7 14411' - 3flgpw@72Psi 39gpn1© 12.1 psi E22 rnn3.7r5) (13.4 al')(113.6 1/inn @00 earl (147.7 1/ton @84 Oar) 145.014 It. (4.3 196 It' - 30 gpm (972 psi 39 W @ 12.1 psi ___ C 04.3 nl) (18.2 W)(113.61/tone .50 Bar) (147.71/ninth .84 Oar) 16 ft. 01611.14.9 2560'(23.8 3flgpm(97.2 list 81t' 120 1n04.9 rn) nr't (113.6 1/orin @50 Burt - - l8 ft- ole ft. l5.5 32451(30.1 33 give 198.7 psi (124.91/ sly. F2Z 005.5n) re') tics @60 earl - - 2011.020 ft (6.1 400)1' (372 40 gpo @125 p si 1151.4 - - A1Y 020 006.1 n) rat) iron .00 to,) Approved Temperature Ratings Approved 0000tolreono A -130 'F (57 'C)ued 175 'F(79 'C) W. Standard so,texeunouvtod escutdsenr,s Only 8-130 '1(57 'C). 155'F (68 'Cl 044175 'F ( 'C) Approved Ft )o,5 X - Standard nurf000-n,ouvted nso,tolrnnro or the Mien-test' C-155'Flso'C1175'F(79'C12tc'F(93'C(.and . 1 ess.0 000. Wrote Polyester. and oh Model l-iddjustablnEsouttheont '1(141 206 'C) 0-108 '1(68 'CL 175'1(79 C), Old 200 'F(93 'C) ntser - Standard sort000-nroovtnd esodohnnrs on 8,0 Mionofast' Model F-i drfsstable Euorfdsoai. or recessed sin, no E-1 55'F 168'Cl - 2 Miaonta5c' MeddE-1.E-2,urE-3 Recessed Encctthnon F - 105 'F (60 C). and 175 'F )79 'C) Z - Standard surfaxn-nmourtnd escutcheons on the Miecinotic 0-175 'F(79 'C) Mood E-1 Recessed Eucxtxtrnnn. Footnotes Pert number shover is the base part vurrbnr. For complete pun .-be,, refer to current Viking price list sd,Oduts 'Motto It-factor ornaserenwrl clown is when plttnourn 0 measured vi Bar. When p,nssew 8 n,oa500d in We. dde the nw6ix ((-tacta, nlroorr by 10.0. This Chad shown listings and approveS available at time 01 printing. Clod, with the ,nonotexferer for any additional app,nsafn. oULas Listed for use in the U.S. and Canada. To dntnnrdnn Mirmnun, Wafer Supply Requirnotnvr for areas of connrnge whore length end nidth of actual spencer 5900mg ate net equal. 5051011,0 3mlaoirnonl Sprinkler Spacing'fmmh the Chart 1501 is equal to or greater then the lager of the c011ar spacing (lnvgtt, or oidnr( dimensions used. Example: When using 10-6' 13-0' sprinkler spacing, provide Sn 'Minimum Water Supply Requlrernenr listed in the n/mad for 14.0 14.0• spaying. For aloes of coverage smaller 0ev n/laWn, use tha 'Minimum Wet,, Supply Rnquiromevf I, the appropriate honed owxp Icr the noel large, area listed. The distevue from sprinhtorn to calls shell net oxuand one-hull the-Maximum Sprinkler Spacing- listed for me'Minimum Water Supply Roqoilneav7 used. 'oULus Listed as ovrrasion-rnsistant. Form No. P051393 18.08.23X Rev 18.2 Page 6 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 817-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorpcom Page 5 of 6 STANDARD/QUICK RESPONSE N4 EXTENDED COVERAGE Ila PENDENT SPRINKLER rttii VK534 (K11.2) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 817-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.viklnggrouplcc.com ww stiLes Llslina Reautrements: EC-ELO Pendent Sprinkler VK534 is stiLes Listed as indicated in Approval Chat 1 for installation in accordance with the latest edition of NFPA 13 for extended coverage pendant spray sprinklers as indicated below: The minimum water supplies and maximum areas of coverage shown in Approval Chart 1 am designed to preside the following design densities: 0.10 gpratri (4.1 mm/rein) for Light Hazard densities: 0.15 gprnfft' (6.1 nnnimirr) for Ordinary-Hazard Group I densities: 0.2 gpm/fL' (8.1 mm/mm) for Ordinary-Hazard Group 0 densities. The sprinkler installation rules contained in NFPA 13 for extended coverage pendent spray sprinklers must be followed. - Viking EC-ELO Fondest Sprinklers am CULUS Listed for use in unobstructed construction, and noncombustible Obstructed construction consisting of solid steel and/or concrete beams as defined In the latest edition of NFPA 13. - Ceiling elope not to exceed 2)12 (9.5'). lion. %lkina ECO4I-ELO Pendent Sernnkler VK534 is soocificalln etiLos Listed for Ordrnaiv Haaard Occsnancws: - For non-combustible obstructed constrscton within trusses or bar joists having non-combustible web members greater than V (25.4 mm) when applying the 4 times obstruction criteria rule as defined in NFPA 13 under 'Obstructions to Sprinkler Discharge Pattern Development'. For installation under concrete less when installed as bRows: The sterns of the concrete tee construction must be spaced between 31t(0.9 w) and 78.6 in (2.3 ml on center. The depth of the concrete tees mast not exceed 30 in (762 mm). The nnskirnam permitted ranoete tee bergtr Is 329(9.8 m). However, where the concrete tee length exceeds 328)9.0 m), non-cumboslible baffles. equal in height to the depth of the tees, can be installed so that the space between the tees does not exceed 329(9.8 m). the sprintder deflector is Is be Located in horizontal plane at or above V (25.4 mm) below the bottom of the concrete lee sterns. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA. LPCB, APSAD. VdS or other similar organizations, and also with the previsions of governmental codes, ordinances, and standards, whenever applicable. Visit UIV viilig wetlsitn iCr CIV latest VUltlUfl Ci 1115 t0L41111501 COld J09V WVVWflt,(ifl99lUUiii.LUiil J Ceiling Opening Size: 3/4" 2-5116" (59 mm) minimum (20 mm) 2-112" (64 mm) maximum NPT (54 hl8 1 24/8" 4 TT T 1-112" (60 m ) 1-3/4" 2" 38 mm) (45 mm) (51 mm) Mmn. Max Installed with a standard Installed with a Microfast Nob At manirnurn, udaptor to (38 mm) 1/8 surface-mounted Model F-I Adjustable noposnd 1/2' 113 non) from fur escutcheon Escutcheon 01 rattIng Figure 3: Sprinkler Dimensions with a Standard Escutcheon and the Model F-i Adjustable Escutcheon 2-118' (54 mm) 4 11ar1.v "T"-118 1-3/4" (29 mm) (45 elm) ,, Min. . Ceiling Opening Size: 2-5/16" (59 mm) minimum 2-1/2" (64 mm) maximum 2-118" - (54 mm) ., k-n--.- 1 F 2"" ,./ (29 mm) (51 mm) MAX. Mm. Installed with a Installed with a Model Model E-1 Recessed E-2 Thread-on Recessed Escutcheon Escutcheon Figure 4: Sprinkler Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F_051393 18.08.23X Rev 18.2 Form No. F_051393 18.08.23X Rev 18.2 Replaces Form F_051393 Rev 15.1 (added note regarding logos) Page 1 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-946-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@viklngcorp.com Visit the Viking website for the latest edition of this technical data page www.viklnggroupinc,com DESCRIPTION Viking EC/QREC Upright Sprinkler VK532 is a thermosensitive spray sprinkler available in several different finishes and temperature ratings to meet varying design requirements. The extra-large orifice produces the flows required to meet Light and Ordinary Hazard density re- quirements at lower pressures than standard orifice or large orifice sprinklers. The glass bulb operating element and special deflector characteristics meet the challenges of quick response extended coverage standards. Upright Sprinkler VK532 is cULus Listed as standard and quick response and FM Approved as quick response. The special Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, ENT coating has been investigated for installation in corrosive atmospheres. See Approval Charts. LISTINGS AND APPROVALS cULus Listed: Category VNIV NOTE As 00 May 2n18 all logos 100010000T.- FM Approved: Class 2022 'd 100,0000*0,001010000. Refer to Approval Chart 1 and Design Criteria for cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria for FM Approval requirements that must be followed. TECHNICAL DATA Specifications: Minimum Operating Pressure: Refer to the Approval Charts. Maximum Working Pressure: 175 psi (12 Bar). Factory tested hydrostatically to 500 psi (34.5 bar). Factory tested hydrostatically 10500 psi (34.5 bar). Thread size: 3/4" (20 mm) NPT Nominal K-Factor 11,2 U.S. (161.3 metrict( t Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Glass-bulb fluid temperature rated to -65 "F (-55 'C) Overall Length: 2-5/16 (59 mm) Material Standards: Sprinkler Frame: Brass UNS-C84400 Deflector: Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on bath sides with Teflon Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Capper UNS-C11000 and Stainless Steel UNS-530400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinkler. Belleville Spring-Exposed, Screw and Pipcap-ENT plated. Ordering Information: (Also refer 10 the current Viking price list.) Order Viking EC/OREC Upright Sprinkler VK532 by first adding the appropriate suffix for the sprinkler finish and then the appro- priate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A. Chrome = F, White Polyesters M-/W, Black Polyester = M-/B, and ENT = JN Temperature Suffix: 135°F (57 'C) = A, 155 'F (68 *C).= B, 175 "F (79 "C) = D. 200 'F (93 'C) = E, and 286 'F (141 'C) = G For example, sprinkler VK532 with a Brass finish and a 155 'F (68 'C) temperature rating = Part No. 08687A8 Available Finishes And Temperature Ratings: Refer to Table 1, Accessories: (Also refer to the Viking website) Sprinkler Wrenches: Standard Wrench: Part No. 05118CW/B (available Since 1981) Wrench for recessed pendent sprinkler. Part No. 11663W/B" (available since 2001) "'A '/o ratchet is required (not available from Viking). Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) Page 2 of 6 STANDARDIQUICK RESPONSE EXTENDED COVERAGE UPRIGHT SPRINKLER VK532 (KII.2) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-8184680 Email: techsvcs@viklngcorp.com Visit the Viking website for the latest edition of this technical data page www.vlkinggroupinc.com INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 2$ for Inspection, Testing and Maintenance requirements. AVAILABILITY Viking Sprinkler VK532 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Protective Sprinkler Clip Wrench Flat Figure 1: Standard Sprinkler Wrench 05118CM/B Form No. F053114 18.08.23X Rev 18.2 Replaces Form No. F_053114 Rev 18.1 Form No. F_053114 18.08.23X Rev 18.2 (Revised ordering information.) Page 3 of 6 STANDARD/QUICK RESPONSE I EXTENDED COVERAGE I F,IG€ 'sJ I I(I UPRIGHT SPRINKLER VK532 (K112) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 817-384-5464 Fax: 269-818-1680 Email: techsvcs@viklngcorp.com Visit the Viking webalte for the latest edition of this technical data page www.vlklnggroupinc.com TABLE 1: - nlJT'perat 4 AVAILABLE SPRINKLER TEMPERATURE :Spro ir*icifrsx RATINGS AND FINISHES Ordinary 135 'F (57 'C) 100 F (38 'C) Orange Ordinary 155 'F (68 'C) 300 ¶ (38 'C) Red Intermediate 175 'F (79 'C) 150 'F (65 'C) Yellow Intermediate 200 'F (93 'C) 150 'F (65 'C) Green High 286 'F (141 'C) 225 'F (107 'C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester°, Black Polyesl&, and ENT Corrosion-Resistant Coatings': ENT Footnotes The sprinkler temperature rating is stamped on the deflector. Based on NFPA-13. Other limits may apply, depending on tIn loading, sprinkler location, and 051cr requirements nf the Authority Having Jurisdiction. Refer to specific installation standards. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Chart These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat- ible with on suitable for the proposed environment For ENT sprinklers, all exposed surfaces and the waterway, are coated, but note that the spring is exposed. Page 4 of 6 STANDARD/QUICK RESPONSE ,qMjKjNGg EXTENDED COVERAGE UPRIGHT SPRINKLER VK532 (KII.2) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 871-384-5464 Fax: 269-818-1680 Email: techsvcsvtkingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com WT fro Sp,leldnr Bun. NPT Thread StaN Noerinut K.pador ______ Munlnrire, Water Overall Length Port Nurnb.e' SIN Working Preo.uoo tnclrm err,, U.S. noble'I e8087 up,rgnr 1,11(532 3/4 20 11.2 161.3 175 psi 112 Burl 2-5/16 59 Minimum Water Supply Reqolmnmoetu' Uothrgn and Apprenote' Moo. Sprinkler ItochnoW (Refer utno to UL Design Spacing Am. par Criteria) Light HWard Ordtnory Hno,d Geaupi ordinary Haee,d Group B Sprinkler Flow I Prnoso,n Flow I Prn000mn Free I Prnnoore SOLo,' Standout Response lti ft. oltirl.14.9 256n'(23.8 - 308prrr@11.SPit SI oyer(420.7psi Cl CO mu4.9wf vi') 1143.gunnn@.79Bar) 1103.1 lJwrr(41.43Bar) lfi fl. olit ft. l5.5 3245/130.1 - 4ggpms@ 19.1 psi 650prn@33.7psi Ci C2 w05.srrl c') 1t85.5Uein@1.32Bar) 1246.1 Uerin@2.32Bar) 2c ft. n2O ft. I6.1 4005/137.2 60gpm@28.7psi 809prn/451.Opsi C1. C2 ron 6.1 ml m°( - (227.1 L/re/n @1.90 Burl (352.5 LOom @3.52 Sac) Quick Response 12 fl. 0121t13.7 144 ft' 359per@7.2psi 3990rn@ 12.1 psi 01, D2 w03.7r01 (13.4 m) - (113.6LJr,sn@.sOeur) (147.7L/rsn@.84Bur) 14 It. 014 ft. (4.3 190 11' 309pm @7.2 psi 39 elan @12.1 psi Dl 02 504.3w) 118.2 mn'l - (113.6 L/flrin @50 Oar) (147.7 L/rnin /4.84 Burt 161L01611(4.9 2565(23.8 30tp.s7.2psi Br 62 eru4.901) or') 1113.6L/rnin(4.56Bar) - - lfilt.ol8lt(S.5 3245/(30.1 3308rn@8.7 psi 1124.9/J 81 62 rnus.trnl nif( min @.60Bar) - 20 IL 020 It. (6.1 4005(37.2 'tOgpvr @12.8 psi 1151.4 Al F2 mu 6.1 Or) Or') Unse /4 .88 Bar) - - Approved Temperature Rations A -130 'F (57 'C)ued 175 'F(79 'Cl 6-135 'P157 'Cl. 108 'P168 'Cl, and 175 'F (79 'C) Approved Finishes C -155 'F (68 C), 175'F(79'C). 300'F 193 'Cl. and 286'FfI41 'Cl 1-Brass. Chrome, White Polyester. and Blank Polyester D-155'F(68'C) 2-fe/i0 0-155 'F (60 'C). and 175T (79 'C) F -175 'F(79 'C) Footnotes Part number slsuson is the hose purr number. For camp/ore purr nowber, refer to ourmvl toting price list sdroduit. ' Metric Matter measurement shown is when preso,un,s measaod fi Bin. When pressure it eroasured a, kpo.diside 510 more, K-Iucvur shown by 10.0. This chart shows 0550gs and app-is available at time or proving. Coeds with 010 manufacturer for any additional approve/v ct/Los Listed for use in the U.S. and Canada. To determine 'Minimum Water Supply RoquiremenC for umus otooveruge whom length and width of actual sprinkler spacing are not equal, soled rho 'Macovum Sprtok/er Spacing' from the ntsart trial is equal to or greater than the larger or the uofuul spacing (length or width) dimensions used. Euamplo: When 0/Oe 55•.fi 13.0' sprinkler spacing. provide the Mivrinun Water Supply Requirement' listed in the sharI for 14.0' 014-0' spacing. For areas or coverage smaller nrurr sfruins. use the 'Mmmcm Warm Supply Requirement "in the appropriate hazard group for the nest /vigor area listed. The distanne from sprinklers to *ails nba/loot enceed ono-hu/1 the'Man/mom Sprinkler Spacing' listed err the 'Minimum Water Supply R,gulmennt' used. ct/Los Listed as corrosion-ms/stunt. Form No. P053114 18.08.23X Rev 18.2 1 Form No. F 053114 18.08.23X Rev 18.2 Page 5 of 6 STANDARD/QUICK RESPONSE EXTENDED COVERAGE la I*.IG® SsJ UPRIGHT SPRINKLER VK532 (K11.2) I The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 817-384-5454 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.viklnggroupinc.com clJLus Listing Rmsdre,nentx: EC-ELO Upright Sprinkler VK532 is cULus Listed as indicated in Approval Chart I for installation in accordance with the latest edition of NFPA 13 for extended coverage upright sprinklers an indicated below. The minimum water supplies and maximum areas of coverage shown in Approval Chart 1 are designed to preside the following design densities; 0.10 gpmlrt' (4.1 mn/mm) for Light Hazard densities; 0.15 gprnlft' (6.1 inmfmin) for Ordinary-Hazard Group I densities; 0.2 gpmfft.' (8.1 rnnilmin) for Ordinary-Hazard Group II densities. - The sprinkler installation odes contained in NFPA 13 for extended coverage upright spray sprinklers must be followed. - Viking EC-ELO Upright Sprinklers are cULus Listed For use in unobstructed construction, and noncombustible obstructed construction consisting of solid steel and/or concrete beams as defined in the latest edition of NFPA 13. - Ceiling slope not to exceed 2/12 (9.5). tine. Vildno ECOH-ELO Uerloht Sorinlif en VK532 is specifically CULUS Listed for Ordinary Hawed Occupancies: For nov-combustible Obstructed construction within tresses or bar joints having non-combustible web members greater than 1' (25.4 mm) when applying the 4 times obstruction criteria rule as defined in NFPA 13 under 'Obstructions In Sprinkler Discharge Pattern Development'. For installation under concrete tees when installed as follows: The sterns of the concrete lee construction must be spaced between 38)0.9 ref and 78-Sin (2.5 m) on center. The depth of the concrete lees must not exceed 30 in (762 mm). The maximum pmrnthed concrete tee length 1s32 ft (9.6 m). However, where the concrete fee length exceeds 32 ft (9.8 M), non-crontiustible buttes, equal in height to the depth of the lees, can be Instated so that the space between the tees does not exceed 32 ft (9.8 m). The sprinkler deflector is to he located in a horizontal plane at or above I' (25.4 mm) below the bottom of the concrete fee sterns. When Ste sprinkler deflector is located higher than a horizontal plane 1' (25.4 mm) beneath the bottom of the concrete tee stems, the obstruc- tion to sprinkler discharge criteria requirements of NFPA 13 for extended coverage upright sprinklers applies. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No, F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Page 6 of 6 STANDARD/QUICK RESPONSE I 41i IJI4G TECHNICAL DATA EXTENDED COVERAGE UPRIGHT SPRINKLER VK532 (KII.2) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269.818-1680 Email: techsvcs@vikingcorp.com Visit the Viking webslte for the latest edition of this technical data page www.viklnggroUpinc.com vp - -......ii,' - .. . • Mandmium Spirrideir Maximum Area Refer to Design Criteria bolo~ FM Ap novel Smacino per Sprinkler NOTE FM installation gxstetn: may differ JUpright from cULos and/or NFPA criteria. Refer to the latest applicable FM Loss Prevention Data Sheets (including 2-0 and 3-26). Sprinkler VK532 16 ft. 016 ft. (4.9 m 4.9 m) I 256 ftr (23.8 mr) Al 18 ft 018 ft. (5.5 mx 5.5 m) 324 fl' (30.1 or') Al 20 ft. 020 ft. (61 mx 6.1 m) 400 it' (37.5I Al Approved Temperature Ratings Approved Finishes A - 155 -F (68 'C), 175 *F (79 'C), 200 *F (93 'C), and 286 *F (141 'C) 1 I - Brass, Chrome. White Polyesren, Black Polyester, ENT' Footnotes This chart uhoern the Fblitçyrunalr erafiablv at louver prkmrtrfl. Clmeds with the manatadorer hemp additional approvals. To determine Mlensrrn Water Supply Rvquirenreor kim areas or raverege where 1011gm and width or ,ntoin rpntitIdxr sparing are not equal. solnO Ore 'Maetinrxm Sprinkler Spasivg'hurn vredrzrn Mat lsequal tomgroarar Man nrn larger uttho actual spacing pnngfrorwidorl dirnurdiurm used. Example: When using tfl'-gru 13'-O' sprinkler spacing, provide the Minleue Water Supply Roqxaerennt' listed in wo draft for 140' u 14.0' spacing. For areas of coverage seater than srraein. use ow 'Minimum Water Supply Reqiaworvur inan appropriate hazard group for the most larger area Wed. The distance from sp.inoers to walls shot not exceed one-hall the 'Maulmun, oprirldem Sp3000' Intuit toythe 'Miersier Water Supply Roqutimwnr used. 'FM Apprnvod as mensodruesatant - Aino re(ec to Appraroiallruxi2abiove FM Approval Requirements: sprinkler VK532 is FM Approved as a quick response Non-Storage extended coverage upright sprinkler as indicated in the FM Approval Guide for use in occupancy hazard classifications HC-1, HC-2, and HC-3. For specific application and installation requirements, reference the latest applicable FM LOW Prevention Data Sheets (including Data Sheets 2-0 and 3-26). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to; minimum ester supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ grow cULun and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F 080614 for general care, installation, and maintenance Information. Viking sprinklers are to be installed In accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD. VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F053114 18.08.23X Rev 18.2 Form No, F053114 18.08.23X Rev 18.2 Replaces Form No. F053114 Rev 16.1 (Revised ordering information.) lob/Owner Engineer System No. j Secton Location Paragraph Contractor Approved Sobeemitted By [ [o ate ..1111111..........I::i......J victVulic.com I Sprinklers I FireLock° I V34, 1<8.0 I Publication 40.78 40.78 0496flneoV updatedot/2015 02015loetoekcCovepony.hllvghtsretervod. -- 4035 8490 vee A Updated 01/20to 02005 vlpteelic Ceenpany. kit effete reserved. victauliç.cons 2 victaulic.corn I Sprinklers I FireLock I V34, 1<8.0 I Publication 40.78 FireLock® V34, K8.0 jctauIecr Material Siomifficatiorm . ACCS5oris Model V3428 Quick Response 4078 Penitent Deflector Bronze per UNS C22000 Installation Wrench Extended Coverage/Light Hazard (ECLH) Technical Speciflcatioiw Bulb: Glass with glycerin solution Open End: V34 Pendent and Recessed Penitent Roib Nominal Diameter Recessed V34 ApprovaWUsbng See Vekaulle Puhlw.aunn loot U, Product Desaiptioru These Model V34 ECLH sprinklers are designed with a 1<8.0 orifice size and provide added coverage at normal light hazard operating pressures. Each sprinkler is cast with a hex-shaped wrench boss to allow easy tightening from many angles, reducing assembly effort. This sprinkler is available in various temperature ratings (see chart on page 4) and finishes to meet many design requirements. Extended spray coverage is up to 400 square feet (37.2 sq. in) per NFPA 13. Modete V3428 Style Extended Coverage/ Light Hazard - Pendent, Recessed Pendent Nominal Orifice Size 1352/14 mm K Factor 8.0 lmpi11.5 S.I. Nominal Thread Size: 'A' NPT/20mm BSPT Max. Wotldng Pressure: 175 psi/1200 kPa Factory Hydrostatic Test 100% @ 500 psi/3450 kPa Min. Operating Pressure: 7 psi/48kPa Temperature Rating: See chart Foe K-ractoeedoen ptnoeuee S nteooaeed in Bee, eeaoply Si. and, by :oA Exaggerated for clarity Quick Response: 3.0 mm Load Screw: Bronze per UNS C65100 Pip Cap. Bronze per UNS C65100 Spring: Beryllium nickel Seal: Teflon2 tape Frame: Die cast brass 65-30 Lodgement Spring, Stainless steel per UNS S30200 Appmvale/Ustngoe APPROVALS SF. _ Deflectoc Type 1 Pendent I Receoord Peeednnt ___L. ... Approved Ten,peeatoee Appeared Te,eperate.oe Rottogo Ratings F/C" PlC'" 155FI6a'c I IOS'F/ha'C cfil.0O -- ic IPS'F/OYC LI c_1IIti9ac U,Sng, and appe000l as of pesnsw. 501 an tenverosire rotng coeebbe250ne em Appemeed or Wed. Cheek retouch foe Ipecac no,nblnationt. Foe K-rector 0505 peoemrr fo nreanaed he Ban. eeuept SI. enite by 10. Ught Mooed aviv. Sprinkler Funlshes Plain Brass Chrome Plated White Painted Custom Painted VC-250° 'Oct00 ho eegeoiened badeenork of oapontCo. 'UL Stied no FM Approved for coreosian reohoanva. E iPp gNfl Dimenslonro 1 ,,.'iro neon flMHet1 e/./16wne T/51 neon bMu victaulic.corn I Sprinklers I FireLock V34, K80 I Publication 40.78 Room Sizat Sprtnidee Peotmolanco Flaw And P105w,. (Miolmon.) V3428 Room Size Flora Rate End Sprinkler Peouuore GPMLAPM PSi/loPe ron. UI. UI. -----F- —4—.9 16016 26 104 X49 90 73.1 18518 33 170 5385.3 ..................................117.2 40 250 20820 6.1 06.1 150 172.4 Distribution Patternst Models V3428, 420 CCLII Peetdcnt and Recessed Pen/gent Distribution Patterns - Trajectory frU it it 6 it rv.4-28 i spacing 7.i Quick Z4 .1 aictaulic.cons I Sprinklers I FireLock° I V34, K8.0 I Publication 40.78 Ratings: All glass bulbs are rated for temperatures from -650F (-54°C) up to those shown in adjacent table. tensperatree —FPC I Sprinkler Temperature klgticdlc Pall Nominal Tomproatler iMas Ambient Glass 'temperature Bulb aassificatlon ,idwethtoalbon Rating Allowed Color Ordinary A C 13S0F/5C 105°F/6tiC 1000F/3rc1 1000P/38°C Red Ordinary Intermediate C 1750F/790C 150°F/o5°C Yellow intermediate 1 F 200°r/93°C 1500405°C Green -...-.. Available Wrenches. -----..-- ............ I Open End I80td i Pendent .. A , WARNING Always read andunderstand Installation, caee, and —lot— instructions, supplied with each bun of npotn- litton. bat—proceedIng with Installation of any sprinklers. Always nIna, solely glasses and foot protection. Depenussebe and drain tire piping system before attempting to install. rntrwoe an adjust any Victastic piping pendoo Instillation roles, especially those governing ebatnostlon, must be strictly followed. Paintir, piatingi on any ne-coatieg of sprinklers (ether than that supplied by Victaolls) to not allowed. Failure to follow these instructions; could eratolt in serious personal injony and/or property damage. The owner In responsible for maintaining the tire protection system and denlces in proper operating condition. For O minimum maintenance and inspection reqalrensnsls, refer to the current National Fire Protection Association pam- phlet that describes care and onalnteosoece of sprinkler systems. In addItion, the aulbmtty basing Imlodiottoet may base additional maintenance, testIng, and inopectlaa erqslremnoto that must be followed. If you need additional copies of thin publication, unit you bone any questions aboat tire sate installation of this product, contact Victastiw World Headquarters, P.O. Boo 31, Easton, Pennsyteania 180444031 USA, Telephone: 001-610-559.3300. NOTES: NOTES A. Data shown tiapprnolrnaln and carl vary dun to differences in installation. 8. These graphs 810520 app,odrrrata ca/mew/os U001oert506 end ewttcralffngpattanrt for niesa speciffn Vvtautc Firehodi Autornetti Sprinklers. They ale provided an htcornaffnrtnrgudance in aooialrG ohotruotiore to spdrtdms and strerald rat be used as ndrrinranr sprinkler spaviop rndet Anlnstolta6or. Rode, to the appropriate NFPA 5050021 Flre Code or the Authority packrgjurisdidton for spnniflnhdcnrraten regarding obstructions. spacing lnttadatsand area at coverage neqrirnnantr. Failure to 6,09w these gatdeternvovvld adorrsdy cftrert the ceitcenarce of the sprtntderand will told at Undegn, Approvals and Waerantes. C. At patterns are symmetrical to the centerline Of the waterway. 40.78 8496 Ccv A Updated 01/2015 02015 kintaullc COorrpany. All i/girls iesaecnd. victaulic.corn 3 Inoeac.em caterinG, mheradarcoosk, 662200 the t-atinttar.go c,oiacuaulonranc spireolrs Inscroduci And no r12r0i0v1019a5y1i1vtaute lavvlauon,pralca030s, dr cecaveits Iroratarwvcdmewnnneo5noars Ina 9/oauayejon boOr/big. INS IrdoadOer. Area robe brSrarioa In accordawe nor cuncrn 89141,59 1r4ra3ar1115iao001n8y1n5rnw00'n. A InvAded nlrh rovh ,rrinncer It s'vtauffv p44ev/b mr landers lnstatatcr end fIend, 814446 recarans the torI a cnarran prnduvr ocecntcotAna. ar060s end staeaard a,la,,nd11l000acretnpofrornarv,raac,ctunotanaoc,vwn. ctIcmcnr eaorvurnn be. onadlrsculirc,arinaablsauar'o. Irodw,a,5. alter /b Icc wenante ,oA0r or trnvunnel tree eat or cOnrad Aviao5c io,00ralb. Vlvrajic A orrwicrrrna Irrimnark vi Varouric vaerPany, 40.70 8496 9cr. 6 Updated 0012005 02015 11cr/ad/v Company. All rights reserved. victattlic.com 4 •CtaUI,d SERIES GL-QR RECESSED PENDENT SERIES GL-QRJSW LPCBICE RECESSED HORIZONTAL SIDEWALL QUICK RESPONSE i AUTOMATIC SPRINKLERS GL SERIES FIRE SPRINKLER CORPORATION RECESSED PENDENT RECESSED HORIZONTAL SIDEWALL DESCRIPTION AND OPERATION The Globe Quick Response Series GL-QR Sprinkler is a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. While the Quick Response Sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard spray sprinklers are specified but offers the additional feature of greatly increased safety to life. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction. The heart of Globe's Series GL-QR sprinkler proven actuat- ing assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern depending upon the deflector style used. The sprinkler and escutcheon are not factory assembled. Assembly is done in the field. SERIES GL-QRJSW RECESSED TECHNICAL DATA HORIZONTAL SIDEWALL See reverse side for Approvals and Specifications. - Temperature Ratings - 135°F (57°C), 155°F (68°C), 175°F (79°C), 200°F (93°C). 286°F (141°C) Water Working Pressure Rating - 175 psi (12 Bars) Factory tested hydrostatically to 500 psi (34 Bars) Maximum low temperature glass bulb rating is -67°F (-55°C) - Frame - bronze- Deflector - brass - Screw - brass - Lodgement Wire - stainless steel - Bulb seat - copper - Spring - nickel alloy - Seal - teflon Bulb - glass with alcohol based solution, 3mm size Escutcheon Assembly - steel -SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING LASSIFICATI C ON AVAILABLE SPRINKLER BU COLOR N.F.P.A. MAXIMUM TEMPERATURES CEILING TEMPERATURE ORDINARY lSSl/IS6 F src/erc ORANGE/RED 100'T SE/C INTERMEDIATE 11EF/200F 7E/C283°C YELLOW/GREEN 150'F 68°C HIGH - 288°F - 141°C BLUE 225°E .107°C MAR 2018 GFS-100e (FormerlyA-24) QUICK RESPONSE A UTOMA TIC SPRINKLERS GL SERIES RECESSED PENDENT RECESSED HORIZONTAL SIDEWALL SPECIFICATIONS NOMINAL K FACTOR I THREAD 5I LENGTH' I FINISHES I 2.8 (40 metric) J 1/ZNPT (ISern) 2114'(5..7 I I 4.2 (60 mos(cI 1/rNPT(lomm) 2114-(S .7on) I I Factory Bmnzo 5.6 (80nro01c) II2NPT(lsnon) I I 2 1W(5.7orr) I CBomo I I I Potyeste° 8.0 (ll5metitc) 1/2°NPT (15mm) 2 114'(5 7cre) I Black Polyester°-' 8.0 (115 metric) 3147'JPT(20non) 27/1E/(6.2cm) NOTE-- METRIC C0r(VERSlONSJREAPPROSaIATE. 'WORIZONTALSDEWALLISZRIIE. YINOHESAV/JLADIEON SPEORLORIEE 'eeILABI.EAswuolermcowoslos RESISTJHTWHENDEEOFEDONORSEU. LISTINGS/APPROVALS TEMPERATURE MIII. K NYC-BOB DISTANCE STYLE HAZARD'r,135-F) 15F 175F SIN FACTOR 101.82.6 20T 286F dJLe, FM'T LPCB' CE MEA BETWEEN (6E/C)I (79°C) (93°C) I (141C) SPRI GL280I 2.8 111 0 X S X X S RECESSED Gl41 42 LII X X 5 5 X X - '- x - x X x PENDENT 5.6 80° (W NFl) LWOH 191/OH X X X X X I X X X X S 5 X X - - - X G15106 I 8.0 191/OH X X J X X X X X X X X G128269 28 1 LII S xix x S X - - - X 6(1.81 RECESSED 0L42269 4.2 UI S X I X X X X - - - X HORIZONTAL GL56269 5.6 UI/OH X S I x X X X -. - - X SIDEWALL GL5627° 5.6 191/OH X X I X X X - - X X - 01812791 8.0 191/OH X X j X IX X I - .- - 'SPHINKLURSSPIAI.LOEUTDFLDAS PERTHE000UIRCMENTSOF NFPA1SANDAJYOITIER RELOTED DOCUMENTS. '206'F (141-C) LFCR &dJLAS LISTED ONLY °HORIZOWTALSEEWOIJ.GILAsUSIED FOR DEFLECTOR 410 I2'80.OW THE CEDiNG, FM REPROVED 6' TO 6' BELOWWECZIUNS, 'BRASS FINISH ONLY INSTAU.I09ACCOIDONISTO BSSDOAND ANY OTHER RELATED DEOJMEWTS OIL ORDINARY HAZARD "112'ADAJSTABLE RECESSES ESOJrT5/EONSARE 08008100 FOR FMUPPROGED SF0/TRIERS. LH1EJG HAZARD Y9CD REF. NO. TUTORS 117 OFT FOR RETROFIT ONLY FRICTiON RI RECESSED ESCUTCHEON PART NUMBERS WHITE CHROME WHITE CHROME lIE ADJUSTABLE TIE ADJUSTABLE SIC ADJUSTABLE TIC ADJUSTABLE IIENPT 332073W 332071 325426W 325420 L!ffT 326002W 326000 325427W I 325423 ORDERING INFORMATION GLOBES PRODUCT WARRANTY SPECIFY Globe agrees to repair or replace any of its own manufactured Quantity- SIN - Style Orifice products round to be defective in material or workmanship for a Thread Size 'Temperature' Finishes desired period of one year from date of shipment- Quantity - Wrenches. P/N 325391 (liT); P/N 325401 (3/4) For Specific details of our warranty please refer to Price List Quantity - Protective Caps - P/N 327109-CAP (Friction Fit Recessed) Terms and Conditions of Sale (Our Price List). Gg 4077 AIRPARK DRIVE. STANDISH, MICHIGAN 48658 989-846.4583 FAX 989-846-9231 PRE SPRINKLER CC'P.PORATtuIi 1-800-248-0278 eww.globespririkler.cem MAR 2018 PRINTED U.S.A. GFS-105e (Fornrerty A.24) 4 EL ]V[ODSE A; Nil I U 'I. b. I At U-V \i) E!JI ir t Bull Moose Fire Sprinkler Pipe Product e (nthes) 1 11/4 fi/z it As the, leading supplier of steel si r pipe, we understand that there are no second chances in fire suppressiok You need products of enduring quaLity exceptional strength—plus reliable service. You need Bull Moose. W - - - 77 iti D IREO4Q ADA6E OTHE BNEITS/SEV(S:'4 UL Listed (US & Canada) and FMapprøved We have the most stocking locatlQns Ixhe ndtry ASTM A)35 and A795 Type E drade A Certf led for best deLivers' and avallabdit' Plain end or roll groove compl;eswith.NFPA13 .13R:.ap 14. . . . I I ' Eddy uard II' bctenaL'relstant lntmatqoating dus terIsIcs :.:,,. •.,. . .. ...1. Alb" :. ........ j . I Custpm 1enth;optlons - çR Of .J rj. • Ht ippedat,anlztIon y fpjpT etd tasted ied1I_Pipe® red or black pipe eLimites fitd paintIri $ om tlble'for usein wet, dry,preactiQn and'&,uge: __________________ • 'sprljler systems ___________ • The hIyz maker with EPDsto heL ea LED pdints). Bull Moose Fire Uuminal PIpE Size (nths) ,, Sprinkler Pipe Product 11/4 h 11/2 II Information 2 21/2 Ii 'I 1 _ - 1 0 ;J Ri'WIi1i*j PI!Y JW'WMiI'I — P910 Max.'5 End Gap Max4 Pressure Mae.t End Load Nominal Dinimisions Net wt. O.D. . A 8 C Size Inthes Indies psi . U. Inches IndIes Indies oiá.z 11071 11011 kP N mm mm non . Kg. 1W - 1.660 .0.06 300 649 2.75 4.38- 181 3rx214' 1.0 43.4 1.5. 2068 2887 69.9 171.3 46.0 M10x57 0.5 iw 1.900 0.08 500 1.417 3.00 4.62 1.81 %'x2Y,' 1.0 483 30 3,447 6.365- 762 1173 46.0 M10rr57 0.5 2' 2.375 0.13 500 2,214 3.41 512 1.88 34'xZW 1.5 603- 33 3.447 9.848 86.5 1210 47.8 M10x57 0.7 2W 2.875 0.13 500 3244 351 5.63 1.88 Wx2'/0' 2.5 72.0 33 3.447 14.430 993 143.0 47.8 Ml0x57 1.1 3.000 0.13 300 2.120 4.19 5.72 2.00 2.6 757 33 2058 5430 106.4 148.3 50.8 M10x57 12 2' 3500 0.13 500 4,808 4.63 625 1.88 to' 0 2Y.• 2.6 88.9 3.3 3,447 21,387 1.176 158.9 47.8 M10a57 12 4S 4.500 0.19 500 7,948 5.81 7.50 1,97- %'x2%' 3.5 - 1743 4.8 3,447 35.351 147.6 190.5 50.0 M10a57 1.6 1203... 5.5081 0.19 305 7.127 7.02 9.72 2.06 1416*83 7-5 739.7 4.8 2.068 31.701 778.3 246.9 523 • 34 5.563 0.19 3110 7,288 7,09 931 2.04 9'e' 03W 75 7413 4.8 2.058 33.417 180.1 246.6 51.8 M16x83 3.4 168.1.., 6.505 0.19. 300 9,850 8.09 1053 2.13 7.6 • 1657 4.8 Z068 44,258 205.5 2675 54.1 1416*83 • 34 6. 019 8.09 10.53 2.13 44'x3W 7.6 788.3 4.8 j4%;00 13,753 61,302 205.5 267.5 54.1 8416 083 34 8" 8.638: 0.19 26.278 10.56. 13.56 18.0 219.1 4.8. 3.103 775.885 268.2 344.4 -66.5 M-1 35'x434'- M2OX 121 82 10350 0.13 250 ,679 12.84 16.41 2.62 1'x6W 24.6 - 272.0 3.3 1,724 [!741.905 0.870' 326.1 416.6' 66.5 8424* 165 11.2 is' 12.750 0.13 250 31,902 15.41 18.84 2.62 1'X6W 42.0 3258 .3.3 7.724 391.4 478.5 65.5 8424 x 165 19.7 - olaolr,n.un Onodoblo gap botwMr pipe ends. Minirtuen gop 0. I Mndeouaepinomrnand ond God em 10101 horn 00 10040 bened on mandoe4 wolcirt stool pipe. P1051000 tartr,gs..... - awhr 0015 Ire drIer toorerp note,iolsonllorwag thi84ess. Coo6,d 1100 FIre Prods0n toe 0010115. See Are Ptnlootion Egreyrhee Sotertleal Swot for us" osdA posses ratings. (Sold color coded nr0011 bolt sil ore avaloble urponrorpoese. I Max Erel Gap 1011004 gr0010d stavrlordwolgte plye. Va5.rOsNorna 9108100 pipe oo15 be thltrototoat 9100004. Figure 712 ltigidCoupinrgshovooeeori.nore4or Feature 'gripping teett0'along the coupling keys in dens 1%' .5. ehiolt nrake the FIgoro 772 perlonOpodled tor'ann nveri whore the Ohn10d of rolorion lugreotost. ThIs 1001010 0O3 eSelnotri the 000400 840 1009005 tororppnn T. eon coal doe to k0000sed r1g184y and geppmg 11000 dec109 thee end root. Gesonil Notes olsgie Designer's tonporotbiity to 00t00 prorb00ssuitobte teethe inoendod 50,0100 and 1000000 that Ores-01055010 705195 0,01 petln.ntoore date intrO reromted. Al00ys tood WW understand the installation • 9001 kstntrateccs(n4.1 Never 1010000 ally pipIng component 0100000 oe modtty ergr pipsog delldwrdoselo,ord 5r5 ooplesuorlting and draining tIre oyslmrs 001048 and goohotsoledioe 4810114 bnonritled to b000000li010 toe trIo up0dt150pp0cn0ns. . . . . . Cee5fied Company TYCO FIRE P000UCT2.451NO,th Carr000Av0000. 1084010. Pnnfluyl000ia 19906 8,0400 U.S.A. 80903042 tqCo/ Fire & Building Products Tectrnicat Services. Tel:(800)381-9312! Fax (800) 791-5500 wwwtysedee.edm Grnhell Grooved Fire Protection Products Figuiie 772 . . . .. .• Rigid Coupling Patented . .. . .......... General. Hoiog Dt5e use ttingte lotd to contacted rdaliee to ally question ASTM A-536. Grade 6545-12 eytopnnent must beknnNolaloiydeusgj Description Ito CCaflII It tltn65ldwi that automatic sptiotder I1io foigade red (oplimia 651-Nod paint a qimltfwd ImpeclionSomice. .Hot6ppedgstnlumdafoASTM • - . () [) BoltINallo Ttaec ilea4 Bolts - conlomtittg to 0 . Warranty OSThI A-1, Zinc Noted. (rAin. T0c -. Q . . 11O08psil758422kPa) . Rch omd88sul he an IJ - Metde-noIogtoAS1Mt'568M . SM Gaot (speoly natIon ordering) . Grade AEP0MAvioIet color cude Lmaai horation ambin9En150f(.€6C)lorheproteoi omadTtr9oriOh Ito 72 - systwrts. Not roronimeotfod for ttotr hen 158.8 5jvtmltrjl Tw Fm Prnihcal. tin fir" gipliv -M grein rdllre • syst . . wanady 91181 No ptm242 or noroicets - Trianai(504e 8DM gr000deNocede 0he1515001ig657ly11in50rd5y018er1J91 91056 . pçe pipe or1mssten a Ptntobr556 (Grade -A- peOMA) ti2dm6681oLt-•7mon85a199-,--e-----88fIttenon.......(Sos flb9reotTlplo95turratd n48n noInd3tonA45llaumdjjmaaEno OfFesweswunfsig 04781 Ordos Ordering WgatC siNo4yord Procedure WAMM.• :• Wt81r placing an order irr6ratooreNo p65156 65.atIi88INoplstedsederg89t TreiFre lire tiptoe 772 Ripii 8915918esc804heP1t .nancPe4pec8ythequao5ty,llgtonntjn5g euotden5399aolflonrNootnoylameud5 N aded. Grade A OPtIMA, Prelottlottod I (GsdeAOP0MA)orGe'OldTri.056, . . ymFire and * . - 10 So s075601s dagr ohea4No6to No*gr Grhe04GrwPPr88v5en,No ce65or 080 04enlomoltot owi88win F28cee to•do - fr 34 prndtNts are as56t11e Uonighed the w88tsror6of8indreA ..• .. . ..•. US.GrraGoNoe.8osogha88rort IN NO BM 2001 TVC0 RRE PROD= BE ___91125w0c11081T SIr OR LUIEFL4 -- . ..... Ycedeci N01450inPI900grm01i 'malnityorL 1Y0TF88WL1)67JtY.KE881ceJr3t. roins T!01Igra tthtide-.' . WMwwwrwRaffamwMawm -Care and 585B898683803fl151535850716ao3 Technical ...• am enance D . The henri 10 resparniotio for the ltrspedion. -Ff92581 it8tJTY6,ZMApz06af9ragJrJ. Data FI9IU8. 772 • system ddenaceurdarme with the JI WLtN1Y91MJ1oerj Stoma Itt'- 12' afEntMrOrIal000Pt60d6ti ANYAMI.60 OflB KttI814Nl97 altrp010le. tiL i ULC. VS, ..: AssociatIon (e.g. NFPA 25). In adzsdrm to 08 MOVED,. 18(8191096 WAARINIIFSO.9E S10PotP6558iStitot-J53t 0d505 Of 003 0tlthOnty 1005 jurC1iO0, MB1tCH4NTABtLJ7Y AND Ff96635 658. taoterg/dypmsajrntornrattort. Theoistallngconsacgororproductmanuurer PAR193t58Pt.W Page 1 of 2 .• July 2004 TFPIB5O Figure 772 Grooved -Coupling tqca/ Fire & Building Products 1enionJSetvx:Tèt (800)381-9312/Fax: (800) 791-5500 GrinneIIGrooved Fire Protection Products Grooved Fittings . Gehéral Matoilal Limited CastRgwwn2ill210.219250260. 501,510, Description. 519. 51008. 5015, 5105 arC 51%- Warranty. .ç' SéPE. proterCme Ductile info ceofonting to 851119-535,Products manufactured W Tyca Ike (ii ymapm ( 3,341a-cotooStee a . tT F t Li (Soisll. -6atoScheduIe40), (Sxes8'-•17ae cheCu1e30, m fshtTeodbyTynt - ntnfxmnpelx 55111A-53 Grade 8 c?cdu . beonirnoforprofr or Tb.gmd80pntwdeaneconom.caI eC.,a0nox: by wnpan,es r atofilfreierdmethodofchangingdleoctiom, - tlon-b.d angepaiot ad ot nfng SIOUOCI. rdd,aoing. or capptng •behrlgoder01(optonat)noneIeod paint gmooed pearly sysenneo. (taoovedtttatgs Hot dipped ofnoningtaASlM productsandconvoneftwhichhwebeensubject ate as'ailabie In, durable ductile iron or A-153 ham not . labecato as doteel eofca1ed , . . Onto 0$ Figure 5105 and 51 .tiltlnts am Ordering Probectton Ass6cbtion (11A), special !adtrrc liUln0 OdIN smaHor . center tu end d ucoobane thou standard rOC re .8u1irx boyTycoFoePtodirete ornoondiloingu. OopendInOnIhe wan and When pirciog an oide, indicate theft/I product fobedxaedu8beOdannyOdemce,5,,01 mulithIll "mi-thene nam PteaSepOOwqOan&ySWOPemtor. Tyco Fire Ptrt/,05otooy9àTyePndnds ilo0oltp2teequlrecegrwat.ornn0otthe ss,andSize toflan assurnm ror adtuizes M9' tenon to conØlay oteolntIna Tb. ace 01 flange. 5/ontO Owned Piping Products, valnos . is ad ndwith Figures accessorins.atd 01185 products am available Veofprndiaxortt/pnabuls.TycoFie 5105 and 519S tlltiags. Contact TF6O Pint thmughoLatheUSCanaAandinWh. Pmojuctsshall Products l&d0b06. through a netagek at dadlibulron rotharn You designenornoroorctiteroemnydudonretntn fleflUirto/&ttudt.reanit joust be i,stalierl dlslnibutoroealestyxu. IN NO EVBI1SHALLTYCO ARE PROOt5:1S BE nd61aiI0aitl9.abe69wi9t05oa,nra-4 . . UA&E. I000N1BACE TORT. S1RICtU58IU1Y edb iiooz Care. and OR UNDER ANY UrrM 12013. 1}RY, FOR NThPloreiónAèrtodon inaddiulan Maintenance - INCIDENTAL INDIRECT. SPECIAL OR m.R .0W. 1W IOW 00t550f79ilIW5A95tfl5352t393flT juiteriidioa ftilo,e to do on may onpalrme The owner a jrosponsible for the inspection. U11719310 LABOR CIIIRG05 ROSNID[ESSOF pa Into davtor tesnog and ma,nteoanceufthnr5reprxtectntn WNDIBETh01AODUCISWASI08ORMG) flntowrucroi01Z for mahrdnjnyft, system and dabus in accordance with the ABOUT TIE POSSI01J1V OF SIICH 13AM5 firo ,eo1éc1fon system and de,tan in proper ap estarsof5wlladort/titnPeotection ANDINffSIIAU.1Y00flREPAROtJC1S' =:Copecthow,cI5,oa The jatalEngcorrtraaoror /ssochlauo.(e.g, NEPA 25), in 01/into to the UABLLflY 0 AN MIDUNT 05UAL 11) THE -0 =12=119=_ zlandazds of any authority hasing juricdhaion 9.4155 PRIM ThehotaOoro5tuOor5rptodtadnuoubu1,oer I7FPffBIT00Mt1EW595IC6' should be contacted relative to any qarsilaro. /IN(4MpAle UIiJYAM7L°LXPOfl05 Technical. o,impaimaxnmosthoimmcelafotynerre. IMPUW. I1CLUWN6 WARRMIIES OF N in recommended that automatic spmlder MEIMATAMITY AND RMW , 4 Data . stoenb&nropocted.Itnlnd.andowWhirwdbp F35lA 5p1rrnafo a qualified IrapectiwSezvbu. OLPM,ULC,VdS.-atrdt.PCO . Nob See fire Protection Sirltmill5t.Sbeirn for cuO Ustirt9llpyrnval infoontation., -. Page IF of 6 . September 2004 TFPIBIO Pa9e2of6 '- . . . TFP1810 Figures 201, 210,219, and 260 c Figun, 201 EJ Flgraee 210 I-cent-I one-1 t- i F;gUM260 fignee 219 8 .kuS1,os0tecao.antooTewP.o&e..e,cPwdun 100000,03,00 ..00thow&)0ewbW,nrn RMeo ,'rn 6,,0 ,to red ow ,unc fleer, Sirs -sirs. F,n Rnee 50ysuod an Er4oivatont St,aintt Ptye) Sloe nor .1 5' Sworn Run Feel I Feet. Feet Feel bees tone Metres I Mater- tavnew Melee 1.9 1 '48 0.6. . 0.3 15 0.8 55 11 5:8 as 0.7. 0.4 0.8 03 1.0 05 2.5 1.0 r~- 3.9 1O 98 3.9 12- .0.5 3.0 12 1 0.6 10.312. 31 12 12.2 IS 03 3.2 1.5 108.5,,. g 1.0 153_ S.0 5.0 -5:5 20 104.3 2.0 :1.0 2315:5 50 03 20 1o. 24 12 SI 24 138.7... 8.0 51 20.0 8.0 24 1.3 6.1 24 -5-- 8.2. 41 20.5 82 741.3. 25 1.3 63 25 - 159.0... -55- -5:8 2.9 1.4 73 29 165 3. 29 48 1.4 -72 - 29 93 1583 20 05 7.6 3.0 216.3,, 13.1 4.9 5- 20 10.8 4.8 -8' 155 210.1 4.0 20 10.0 4.13 1,3 10 163 8.3 81.3 16.5 272.0 . 5.0 25 12.5 5.0 12 193 9.9 ssr 3384 61 20 15.1 61 14grato201 149,00210 Ag,eo219 45 Elbow 96' Elbow Too NO.iw Si. Inctes s5-y 'CtoF ledem -WEceoF 555-01 L Inchos 5-% 15n. flInt Jf'9, t0t tnto 55_ eon 175 0.9 1155: 1.0 5:75: 1.4 .088 465 04 .69.9 05 69.9 05 384.02 0.5. 69.9 05 .44.5 5:y5-j 69.9 128 . 1.6 384220 2.0 03505 5:Z tiT 088 M 0.8 826 0.9 826 52 224 -5t7 1.0 85.3 5572 1.4 0.4T5 953 2.5 224 .0.4 [21- -5 1.0 255: 953 8- 1.4 l.1572 5 953 55 26 . 2.05 0.5. . 16 5 108.11 2:8 ,855 20 0.5. 100.13 32 2M 73.0 5-5 . 24 .55 1207 3.9 523.00 55- 120.7 52 5.00 83 5.00 .. 55,st 118 188 5.0 i27.o 29 ozzo .25A 02 5 825 Y 3.5 033.4 11.3 51 535- 133.4 4.8 . 6 y: -15 139.7 31.3 LI 11 .92 s 1357 is 6.9 384 21 6' 5 826 29 . 1357 155- 6.1 538 133.7 17d 7.7 IM 29.4 16,. 23 159351,0 5 -.ias 54 5:00 1354 14.0 6.6 5 1524 W 62 - -. 165 IleOr - g 12-0 5.4 5:30 165.3 103 84 338 165.1 - 17.8 -1 73 29.4 14 - 6' 5 409 54 165.1 54 5351 165.1 EC8- 11.5 'TIm 2I4' 13. 34 21635wr 420 - 5351 7751 -4KY - - 009.0- .. 1154 156.9 16.6 195.5 20.4 - - - 8' SNE 0400 1554 5351 190.9 15.6 7. 195.5 35: 8- 20.4 3.19 '302 5.8 .4.75 371b § -60.0 5 120 23 JD ur 1233 . .041 2255 272 228.5 32.7 31.8 9.1 - 16' 5 1354 - -18.1 0550 336.0 97 30.4 1550 254.0 420 'TNT 37.8 o 153 P43o16 3861810 Figures 501, 10,519 and 51 ODE CE F.gmo $01 Fgum 510 F1goo 519 llgoro 5100$ - Fig.e901 F(gwo6lo F7oo519 Figo,e5100€ - 45' 507 0w Too 917 Dm70 $0oo S1,6 - ln~hm 48 th6., C 107000 CNF hwSos W 186 mo 645os 2 66509 $ (50wo Lbs. mm 1(q. mm Kg. ow, K mm mm pm, -I.- 1' 44.5 04 0.4 69.9 200 05 69.9 0.. --: - iy 44.5 0.5 69.9 0.5 - 699 0.8 - - - - - 50.8 0.8 325- 826 (7.8 826 1.2 - - - - - - - 210 - 225 57.2 - -ii- 1.0 3.75 953 -- 1.4 3.75 95.3 -- 2.5 r 953 50.8 s 69.9 T 72 31 250 63,5 _53_ 1.6 - s: (09.0 .20 108.0 32 1059 59.4 7 69.9 1.7 - - - . 762 - 24 '. 1720' 25 727.0 11.3 5.4 127.0 724 69.9 3.2 '826 - 29 139.7 $, 6.1 (38.7 7.7 539 1393 06.9 69.9 5,5 - 53$ 89.9 5.4 - 165.1. 153 54 1651 '•963' 71.8 - $39 165.7 056 69.9 6.7 5:05- 720 7y, 13.9 '953 (838.0 70.4 150.9 164 )' 7953 2114 196.9 (217 619 ir Figures 501S, 510S and 519S Fi F'qm501S . E7uoo510S' F7gu.5l9S FigmoSOlS . F1gto Fntlmn Finommoco 6015.5105 & $795 ,500d,no $481007018 Sbat Ppo) Stoo 90' 45' . I es . _!!$_ 7010$ Metnrs Mnfo, M.l 2 3.2 - 1.6 -eD77 Y2 -6713 1,0 0.5 '2,5'-"1.0- -- -i -i - --9ma .5 - 13.0 72 06 3.0 12. 761 4.1 2.1 10,3 4.1 1.2 I 0.6 '3.1.. 1.2 s 019 7.5 .5sr.4 0.7 'ii' 3.7 15 4 63 3.3 ,-163 6.5 774.3 2.0 7.0 54 2.0 1397 8.6 4.1 8.0 - 2.4 73 51' 24 s 5 8.2 747.3 2.5 73 .6.3 25. s3' 2.9 1.4 '72 29 s 9.9 7053 3.0 1.5. 7.6 2.0 13,1 6.6 2151 - 50 2.0 10.0 4.0 45 0700w 90' 01 - NmW EL .'coo W. 't 41 - 6631on 7.66. 70000 2.00 1.8 T5 5(7,0 (18 659 ZZ5 22 3= ' - _ 572 '1.0 76.2 - 35 - - - 635 1.6 85,9 - . 573..76.6 440 76.2 -24 .107.6 139.7.. 826 3.5 724.0' - 325 82.6 8.5 3.9 4.88 124.0 sIn - - P8904076 - 7861810 - Figures 250 and 350 1-6,08-_1 Rpm 390 CoO I6t861 70540200 13gm0350 F818150od S4OS8t012 I0S0*w,0..00fl.6600w,OC ADA CAP® - '. - Patented V t I - N0o6nn10(n.000o I - 1021 curt- , 1..sJ2_ A Iiii' B ceste'oot] Not VVL 3108 25 1 4111 135 31.8 125 47.5 1.89 40.0 0.77 0.3 15 1.900 483 1 137 34.8 2.00 58.8 5.02 513 0.88 8.4 '125 31.8 1.75 44.5 129 40.0 0.92 8.4 - 503 43 5 1.89 48,0 - 0.92 0,4 2 410250 1500.8513 03.97 2.375 C14.50.8 0.0484 1.89 1.28 73.0 50 0.52075.97 1.89 1.28 480.002,320.8 573 0,7 - ,615_250 and 350 Concoomic Rodopm-.G,0000 xG00000 - 0(06' Apwt. WI. Nom(nol 0106 App. W1. Nowthsol $700 Appo.Wl. Site lodlon Lb.S70e . (ncbsS Lbs. $54 (noNes Lbs. mm -Kg 1o.5w, mm Kg. 7018w, mm Kg. '2171¼ 250 1.0 139.7..o3 3.50 42 4.00 5.8 825. - o.s WI 7,9 '005 101.6 2.6 '2n 14 250 1 09 0.6 1.3 as - 350 859 4.4 25 8172 5.00 177.0. .12.2 5.5 '2492 - 2.50- 1.2 - 51714 3.50 6.00 - 72,1 825 0.5 88.9 .vn s.s '76.1...x1¼ 2.50 1.5 5o2 3.50 4.2 5.00 - 12.0 63.5 57 80.9 si'1220 -5.5 250 -' 1.6 5025 -350 4,5 5.00 11.9'26.1..02 63.5 08 gp 2.0 4.6 jx3 9220 '5.4 250 '13 .-..3.50 -11.3301/. 44 .5.00 53504 059 25 sis 1Zi0 - 5,3 2501.3 - 3.50 10.8301% 4.5 5.00 (745 S _ _ 0.6 00.9 20 7770 4.9 -3 382 2.50 825 F.gom 350 1.3 0.6 165.1..63 -4.00 101.6 25 - 5.5 6.00 .1004 1724 21.9 - 100 - 3p2¼ 3410 .,, S54s31o6 1.5 g. 16S.1....X4 4.00 6.0 j 1005 6.00 153.4. 21.6 9.8 '257711.. 00 6.00 21-1 1059 401/. 3.00 '212 2.2 Ii) 682 4.00 1026 6.0 27 1088 6.00 1524 19.5 8.9 48116 350 .23 • 692% 4.00 6.0 7.00 28.0 762-. 1.0 101.6 2.7 12x4 402 350 23 '0076.1... 4.00 6.0 7.00 30.0 75,5 7() 701.6 27 - 1206 77 X 13.6 4024 3.00 762 .7,0 . 2.3 603, 4.00 101.6 6.0 7 1208 777.8 7.00 28.0 12.7 -4 '- 9 3,00 762 6.04 3.2 4.00 1916. 5.9 27 -- .12015 7.00 - 33.0 .15'' 3.00 76.2 2.6 12 _ 60139.7.. 4.00 101.6 6.2 - 29 ' - - Pege6o16 . TFP18I0 Figure 321 FIgee 321 - .!120013 lucolç ten. - 71806847 C In E 51.50. WI. Nominal Clo 8. 5150. WI. Size IndIes 1700. bdIen th0. mm Xg. IndIes mm 1501160114 325 2.0 65404 BZ6 os 202015 3,15 8Z6 65405 6-50 27.2 1-2 16S.1 IZ2 25 x 216 0 v 42 0.0 735 362 p1-9 196.9 16.4 2140250116 8o8x3 365 953 1-9 196.9 16.6 n.25xz 3.75 4.3 9 9 4 " 775 F 95.3 .20 - . 1562 16.6 3.3.1% 425 . 0 8 8 5 ' T 108.0 24 196.9 763 3.3.2 425 88 7.25 37.9 188.0. 2.5 1963 76.8 lo.10.2 9.0057.1• 708.0 . . 26 - 228.6 25.9 4 40 17 52° - •• 10X I0.3 9.00 S7.4 727.0 44 2526 26.0 404015 10210X4 M9-006 12ZO 4-5 - 26.1 4 4 2 540) 10.1 10 100 s '° 127.0 44 , 223.6 263 4.4.2!6 5410 102 . 10 10 6 0 04)0 58.0 127.0 43 . 2284 26.3 5.010 .105 1 '90 8 0 2° 584 727.0 42 378.6 25.5 550 145 12912n3 10.00 85)2 139.7 54 2142 36.4 5o5025 5.50 14.8 .- 12,11204 10.00 005 139.78.7 . . 258.0 365 50503 550 152 . 12o12o5 104)10 60.7 1397 0.9 ' 250.8 35.6 50504 5.50 152 1201206 10.00 1 135.7 7.2 ' . 254.0 367 6o6o2 650 265 1201288 10.00 91.4 11.9 258.8 485 606025 650 265 12o12o10 10.00 91.8 120 . 254.0 41.6 6o603 650 265 726 General Notes: Il18the Oesigno14 re,p0es1b81y In select p.04mb 00405)0 for the 1n7e086d oeroiee and, to nesum ISO thotpmoo.neeetingoeodpmfoenemmthIninnol0000mlod. .15o'oy0rendendondno00udtho bndn20un.nsbn.C6001. 9001 (IN-bOO). 10.0000 009 piping omop0000t or normnl or rnodly any piping deficiencies 0.ittboulflbnt depressurizing and d,eining the oyolem. Material and gesbebsnineSen shoote be "milled 10' be coe.palibbe for the 5900iilcepplesllon. . - Ce.1,tlnd Coinpeny rico FIRE PRODUCTS, 451 North Cen000Auonue. Lansdale, Pennsylnenin 19946 P6,5051 US-A. Poge5ol6 TFP18I0 Figures 391,392,393., 312 and 313 291 LII PJVI Agum - 392 FGm 393 Kg- 312 688000391. Rg,00 313 - W9IO 312 Adapter Nipples, 22'6'Eib- - EWE Appo.Wl. 0.106 Appo.Wl. 'GleE 9Qp5.Wl. - h,d.es tho. 18o6en [be. 2 IndIes Lb.. 8.8. 1 • 4.00 - 0.0 1.75 _ 0.4 1.32 0.4 101.6 0.4 44.5 .02 317 02 - 4.00 0.9 1.75 0.5 1.38 0.5 101.6 0.4 44.5 0.2 311 02 • 4.00. 12 148 04 1.38 0.6 101.6 as 472 0.3 35.1 03 • 4.00 1.9 2.80 0.7 150 1 38J 1.1 101.6 02 50.8 : 03 0.5 • 2' 4.00 2.5 2.25 1.4 1.50 12 7076 1.0 572 (16 38.8 05 • 6.00 5.5 2.62 2.4 1.75 2.2 152.4 25 60.8 1.1 44.5 1.0 6.00 7A 2.88 4.1 2.00 3.3 152.4 3.4 132 1.5 50.8 1.5 6.00 95 3.13 . 5.6 2.00 4.6 7524 43 29.5 2.5 50.8 27 6.00 14.2 3.88 11.1 2.00 87 152.4 6:4 905 10 .502 33 8.00 27.0 4.38 14.0 2.13 9.1 2.0.2 72.2 113 8.4 54.1 4.1 - 12' 8.00 , 33.0 4.28 22.0 225 16.7 21132 . 120 124.0 .10.0 57.2 7.6 cTT 313 . - .. Figures 327 and 341 7327 Figune 34 150 tbs. .E -- 8WL 6108. App5WL 275 2.0 440 .2.5 I - 181$1.3 1' • 2.75 22 4.00 . 32 -L . 609 2.0 101.6 13 325 2.7 4.0 52 F 577 826 12 IL71S Z4 - 3.75 5.0 4.00 8.0 913 23 1074 36 425 7.1. 450 10.2 108.0 .22 101.5 4.6 - - .... 5 119 6.01 172 ii 127314 1574 78 550 17.1 6.00 21.4 -f-- 139,7 7.8 ISZ4 9.7 I 650 275 6.00 26.0 1651 12.5 1254 172 775 47.0 6.00 38.4 Aguro341 - 19&9 .iL ii 1_!?_ Fig. .200 - "Trimline" Adjustable Band Hanger . .• 8. ize Range - 1/2" thru 8" pipe Material - Carbon Steel, Mu. Galvanized to G90 _.. specifications Function - For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features - (1/2" thru 2') Flared edges ease installation foi all pipe types and protect CPVC plastic pipe from . abrasion. Captured deslgn.kpps adjusting nut . . .? from separating with hanger. Hanger Is easily A A installed around pipe (27v" thru B" Spring tnion1o1h nut holds It . • . . . .T..- -. securely in hanger before installation, Adjusting . 1 nut is easily removed. Approvals Underwriters' Laboratories listed (1/2" thru 8") in the. USA (UL) and Canada (cUL) for. steel . 1f ?'HiU 2 iNCH PI1F 2 12 IHNU 8 i'T."Id P11 I; and CPVC plastic pipe and Factory: Mutual Engineering Approved (3/4" thru 8"). Conforms .to Federal Specifications WW-H-171E, Type IQ and Manufacturers Standardization Society SP 69 Type 10 Maximum Temperature - 650°F Finish Mu, Galvanized, For Stainless Steel materi- als, order TOLCOTM Fig. 200WON. Order By - Figure number and pipe size . I, . - •.' ... Dimensions 'Weights -- Pipe. Rod Size Max. Roe, Approx. Size Inch' Metric A B Load Lbs, Length 1/2 3/8 8mm or '10mm 34 24 400 . 11 3/4 3/8 8mm or 10mm 3V2 214 400 11 1 3/8 8mm or 10mm 33/6 21/a 400 12 1 '/, 3/8 8mm or lOjil m 3 `/4 21/c 400 13 1 /2 : 3/8 8mm or 10mm 36 2 7ja 400 14 2 3/8 8mm or 10mm 4/2 3 4.00 15 2'/2: 10mm 51/e 414 00 27 3 3/8 10mm 57/8 4 600 29 31/2; 3/8 10mm . 7/ 5'[4 600 34 3/8. 10mm P4 5 1000 . 35 .5 1/2 . 12mr. 914 6'4 1250 6,6 6 . 1/2 12mm 104 6/4 1250 73 8 1/2 12mm IS/e 83/4 1250 136 Main 0Uice/Menuiaciurin Facility • 13/5 Snripern Ave Comm, C, 92iiig • Il 9O • 13/ 0330 Customer Service • iUX (ii 1,23' p. , . wwwtoico,r4m Dimensions eWeights Rod Max, Ree, Load Lb, Size For Service Temps 650°F 750°F 3/8. 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 Fig. 98'. Rod Stiffener Size Range - Secures 3/8 thru 7/8' hanger rod 'Material - Carbon Steel Function - Secures channel to hanger rod for vertical seismic bracing, Finish - .Electro Galvanized Note Available in HDG finish or Stainless Steel materials. Order By - Figure number i.gc 99 - Al Thread 'od Cut to Length 1" inc cures 3/8" thru7(8" rod in Mate; lal - Carbon Steel Maximum Temperature - 750°F FInisi - Plain Notál--- Available In Electrô-G&vailzed'and HDG finish or Stainless Steel materials. Order By - Figure number, rod dimeter, rod length and finish Fig. 100 - All Thread Rod Full Lengths Size Range -Secures 3/8° thru7/8' rod' In :10' lehgth Material - Carbon Steel t. - Maximum Temperature - 750°F Finish.— Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Ordeç By - Figure number, rod diameter and finish Dimensions -Weights Max Rec, Load Lbs. Rod ' For Service Temps Approx. Size 650°F 7.50°F ., Wt,/100 1/4 240 '215 12 3/8 610 540 29 1/2 1130. 1010 . . 53 5/8 1810 1610 84 3/4 2710 '2420 . 123' 7/8 3770 3360 169 1 4960 4420 222 •1I4 8000 7140 ' 360 1I2 11630 10370 510 Main Off ice/Manunciurin Faciiity 33/5 Sim,11wintwv Cvi'vv. CA 9I9 ' Ph 90 /31 fib(P) • Nx 909 /3/ 0330 ' ' . . . ' . Customer Service ' iPX) /00 '200 . . . Wwwtolco,aorn SIZE- ROD: 1/2' SIZE - SYSTEM PIPE: 8" max. MATERIAL - carbon Steel. I FINISH - Plain or E.G. -LITtNG/APPROyAL- /..;L. &1,500 0 203 - EX 2551 Iv FUNCTION - Attachment component of an AFCON hanger. INSTALLATION - Per NFPA 13 and these instructions, Install on vertical mounting surface. ASSEMBLY/ATTACHMENT - Mounting hole accepts 1/2" or 5/8" fasteners. • FEATURES -Tapped rod bore. . ORDERING - Part # and finish. 556 BRACKET SIZE - ROD: 1/2' SIZE - SYSTEM PIPE: 8" max. • • • MATERIAL - Carbon Steel. FINISH - Plain or E.G.. LISTrNG/APPROVAL- • cliszo3 EX 2551 NOTE - Criteria same as 555 except smooth 17/32" rod bore. • • • Install hanger rod with Vz" nut, • 4/13 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.4-44.3887 www. Afcon.org P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Ncon.org 100 162 REVERSIBLE UNiVERSAL. BEAM CLAMP 3/4" MOUTH RESTRAINING STRAP SIZE - 3/8" and 112" rod. MATERIAL- Ductile iron. FINISH - Plain, E.G. audH.D.G. LISTINGS - Ce 203-EX 2551 <> Approvalgadde -Ape Uaagas FUNCTION - Hanger assembly attachment to steel flange with thitlosess of less than 314". INSTALLATION- PcrNFPA 13 with see screw up or down. Torque -3/8"60 inch lbt.or 1/2"125 inch 1bs. ln the absence ofatorque wrench, engage set bolt finger tight then additionally tighten 1/3 turn. FEATURES 'Listings allow installation with set screw up or down - see drawings. Maintains CONSTANT H.ANGER CENTER -LINE, with set screw up or down. 'Flat throat back to prevent twisting on flange during installation. ORDERING - Part #, rod size and finish. Vail SIZE- One size fits both 3/8" aiid iir rod or set screw. Available lengths 4" and longer. MATERIAL- Carbon Steel. FINISH - MIL Galvanized. LISTINGS,. cAu 203-EX 2551 PATENT- No. 5,897,088 FUNCTION - To aahanndbangerauachntenr in areas subject to INSTALLATION tightto structure and component parts Mlniitiumrenirn on strap: I" L-dimaision is measured fromJsanger rod center tothçsthapard. FEATURES "Fast installation for new construction or retrofit. * Requires no hanger disassembly to install IMPORTANT NOTE: *No Nut Is Required" When installed tight to srsucturc and component parts. (See drawings provided) ORDERING - Part /I and L-dimension. 1/08 APPROVED 8007957 GST 10 X CPVC 1-1/2 300 1.5 8020957 SWG 10 X 'CPVC 1-1/2 300 . 1.5 8008957 GST 20 X 2-1/2 . 850. 1,5 X 4 1475 1.5 • , 8068925 GST 20 SS X 2-1/2 850 . 1.5 8010957 GST 30 X 4 1500 1,5 X 4 1475 1,5 8b09925 GST 25-380 X 4 1500 1.5 X 4 14.75 1.5 • 8022925 SWG 25-380 X 3.1/2 4 1500 1.5 : X 4 1475 1.5 8021957 SWG 20 X 2-1/2 3** 1250 15 8073925 SWG 20 SS X 2-1/2 1250 1.5 8139957 SH GST 20 • X . 3 1050 1.5 X 4 1475 1.5 8141957 Sf1 GST 30 . .4 . 1500 1.5 X 4 1475 1.5 .•. 8140957 SH GST 2OSS . X 3 1050 1,5 • 814257 SH GST 30 SS X ' 4 1500 ' 1.5 -, If 8038957 DSTR I X : 1500 0.035 X 4 1475 0.1050 8037957 DSTR 1-1/2 X 4 1500 0,035 X 4 1475 0,1050 8039957 bsTR 516 X 4 1500 0.037 X 4 1475 0.1050' .8045957 DST 516 X 4 1500 0.188 X 4 1475 0.1875 8046957 TEK50 X . 4 1500 0.250 X 4 1475 0.1875 .8055957 SWDR I X 4 1500 0.037 X 4 1475 0.0600 8056957 SWDR 516 X 4 1500 0.037 X 4 1475 0.0600 8054957 SWDR 1-1/2 X 4 1500 0.037 X 4 1475 0.0600 8137957 SH DSTR I X 4 1500 0.035 X 4 1475 0.1050 8150922 XP 20 X 2 750 0.027 X 4 1475 0.1050 8153922 XP 35 X 3-1/2. 1250 0,043 X 4 1475 0,1050 8061957 SWC2O X 4 * SWG 25-380 Maximum pipe siz;;in composite wood joist allowed by.UL is 3-1/2" SWG 25-380 Maximum pipe size in wood timber or. joist allowed by UL is 4" ** SWG 20 Maximum pipe size in composite wood joist allowed by UL is 2-1/2" _ **3 20 Maximum pipe size in wood timber or joist allowed by UL. is. 3 UL and FM tests were performed in compliance with NFPA-1 3 Standards. Fastening requirement: 5 times weight Of water filled schedule 40 pipe plus 250 pounds 1475 3000 PSI iTLVBUildéx www.itwbuildex.com 800-284-5339 SSS26 TheSjmbo!of&otec$iotr J. U.S. Pat. No. 3921989 Canadian Pat No. 1009680 Othwi Patents Potter Electric, Rd., 1990 GENERAL INFORMATION The Model VSR-F is a cane type neterfiow, switch for use on wet sprinkler systems. It is UL listed and FM Approved for use on steel p.pe; schedules 10 through 40, sizes 2' then 8' (50mmfllnj 200mm). L.PC approved sizes am 2" thru 8' (50mm tIler. 200mm). The unit may also be used esa sectional waterfow detector on large systems. - The unit contains two single pole, double throw, snap action switches and an adjustable, instantly recycling pneumatic re- tard. The switches are athstted when a 110w or 10 gallons per minute (38 LPM) or more Occurs downstream of the device. The itnw condition must esist torn period of time necessary to onetuiine the selected retard period. ENCLOSUR00 The unit in enclosed in a general purpose, die- cast housing. The cover is heed in place with two tamper resin- tent saes'di which require a special key for removal. A field in- statable cover tamper switch in available as an option which may he used to indicate unanttronzed removal of the cover. See bnletin no. 5400775 for installation instructions of this switch, - VSR-F VANETYPE WATERFLOW ALARM SWITCH WITH RETARD tlt.Ut.candcsl3lLinted,FldandLpcsApproved,NyMEA Accepted, CEldaeknd Sàrmicarpro.re: Up to 450 P21(31 EAR) Minimum FlowRateforAlannr:10 GPM (381pM) - M.ximren Surge: 18 FPS (5,5 mIs) ContactRatitrg Two sets otSPDT (Form C) - 15.oAmpsatl2sl2tovAC 2.0 Amps at30VDC Resistive CondultEnfitances: Two knockouts ptonidedforl/2"donduit ErevbomnentalSpecificatiorm: Suitable tririndooreroutdooruse with laclory installed - gasket arid din-cast housing. NEMA4/tP54 Rated Enclosure -usewith appropriate conduit fitting. - Temperature Range: 401`1120F, 4,8'C/48'C Noe-conós/no sleeve factory installed insalidle,- cultoorThis dovrce.s notirdended forapptications in erqttosive SiresAnallable: Steet0ipestheduteslothsu4o,sizes2'(tuu8' - BS 1387 pipe 50mmthru2001nm Nelin Forcepperor plastic pipe use Model VSR-CF, Service Une: - Automatic Sprinkler NR'A-13 One ortwo family dwelling NFPA'130 Residential occupancy up to fourstones NFPA-13R National Fire Alarm Code NFPA-72 Optional: C000rTarnper Switch Kit, Stank No- 0090018 INSTALLATION: See Fltt.2 - - These devices may be rn000tod on horizontal or vertical pipe. On horizontal pipe they should be installed on the topside of the pipe where they will be accessible. The nails should not be en-stalled within 8' (15cm) of tilting which changes the direction of the watertlow or within 24 (60 cm) of a valve or drain. Drain the system and drill a hole in the pipe using a circubrsaw in a slow speed drIlL The 2' (50non) and 2 lIZ' (05mm) devices require a hole with a diameter of 1 1/4' * 1/8'- 1/16' (33mm ±2mm). AD Other- sizes requite a hole with a diameter of 2' ±1/8' (5(Imm±2mm). - - - ------------- Clean the inside pipe of at growth or ether material for a die- tame equal to the pipe diameter on ether side of thejeole. Roll the vane so that it may be inserted into the hole; donot bend or crease It. Insert the vane so that the arrow on the saddle points in the direction of the watertlarn. lanaI the saddle strap and lighten nuts alternately to an eventual 508-lbs. (68 n-m) of torque (see Fig. 2). The vane must trot rub the inside of the pipe or bind in any way. Speciticatlons subject to change without notice. PotterEtectrinSigeid Company 2001 C,in9 Rood. St Loan. MO. 63146-4161 'Pfmnn-000.325,3936r'Canada 8884182-1633'eeempottnrvigeoLnonr eeoflto.ousu trICttm1.REvw PAGE 1 GPO - MFG.mm0761.lmz - ®Potr - The Symbol of Protection VSR-F VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD P113,1 - FlG,2 SWITCH TERML CONNECTIONS wnns,u Luoco warm -. - fr ray tome mote err rut CLAMPING PLATE - "•• Gloom ram o- nec TERWNAL moan anazeecw - In Greece mc rune reef (oltut ovecemo rut osra Inc 00oy. .me DC 1010Am lesser OF room rc(Xnteuy 0 PoC.tue - reese ourra 't . A senec e .me.., . -e - - - - - ecunuac rae DC F,cruwr a welD 'o' In asoes. noon .me as e.ncnce CAUTION: - - - 'd An oninsulated section a I single condudorshoulduot be looped around the harmi- - ----. - (alth cov. in O) - fAt sQE - mc ale - (1O, ro oteet 01,0,0 0*01.) run' mr/a' (an,an to arowee)00.101 serve as -sepa- rate connections. The wire most be sa'eeeed,-.thbteby a n— - - providing snpervrsionofthe - - - - - - - connection in the owed that - rue we) - OIODC moon scenes (oseeat thewiombecoerasdinlddged 0 ro-.w le-er a-as oo-m from under the lezntinat. One. lOe.-3O - FIG, 3 TYPICAL ELEC'IRICAL CONNEC11ONS - - - - -: - 1. The Model 1?SR-F has tee I To remove knockouts: Place ooilnhn., ann can be read to screw driver at ridge of t.nodr- operate a onlr00 stobart pro- pintary or rerrrota d8oatn0 ours, not in the center. - ustidlo operate. local .&W cal eentrynoof be coaled to dn.ree - 3. Forcupon 8 enrato 'Switch T rotC tea deumrog d on nero (Flg. 1), APPUCATIONWARNINGI ---Owelnihe pnsslbdrty, of unhrlendeefldindrerges caused by pressure sooges, trapped nit, or short retard times. waterllow switches- -- that are monitoring wet pipe sprinGer systems shouldshouldnot be used as the sole initiating device to discharge AFFF. deluge, or chemical suppression Systems- TESTING - TESTING The frequency of inspection and testing for the model VSR-F and its associated protective monitoring system should twin accordance with applbceble NFPA Codes and Standards and/or the authority having jurisdiction (manufacturer recommends - quarterly or mom frequently)-- If provided, the inspeclait's test value, that is usually located at the end of the most remote brunch line, should always be used for test purposes. If there ate no provisions for resting the operation of the flow detection device on the system, application or the VSR-F in not recommended or advisable. 0, minimum flow of 10 gpm (38 t.pm) in required to activate this device. - - IMPORTANT N01NOTICE-Please advise the person responsible for testing 01 the Ire protection system that thin system roust be tested in accordance with the testing instructions. - - Pnre.ccoruusu - racf.mnaml.oevw PAGEOOF2 IrFG.nso.m76,.lmz - ®PO1TER BELLS The Symbol ofprotedion ULUsted O SizesAvailable: 6 (150mm), 8"(200mm) and 1O"(250mm) Voltages Available: 24VAC 12OVAC 12 DC(102t0 15.6) Polarized 24VDC(20.4to31.2) Polarized n5te ', Service Use: ForeAlarm GeneralSignaring BurglarAlarm Environment Indoor or outdoor use (See Note I) -40o150F(-40toWC) oserequiresweatherproof Tennination: 414o. I8AWG stranded wires 6 BELL SHOWN Finish: Red powdercoaling Optional: Model BBK-1 weatheiproofbadcbox Thete vlbthting type bells are designed for use as fire, burglar or general signaling devices. They have low power con- sumption and high decibel ratings. The unit mounts on a standard 4 (101mm) square electrical box for indoor use or on a model 88K-1 weatherproof backbox for outdoor applications. Weatherproof badteox model 88K-1. Stock No. ls0000t. ALL DC BELLS ARE POLARIZED AND HAVE BUILT-IN TRANSIENT PROTECTION: lio MinirnumdBratingsare calculated from integratedsound pressure measurements madeatundenwritersLaboratorjesas Specified in UL Standard 464. UL temperature range is-3O to 150F (-34 to 66C). Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of Output levels in an actual installation. PoorareemsigoCw '2081 c.ansa. at WI USA - tocr.en85000n.nzvs Plan OF: - - - - Iwe5u00776.la 7*0811* lm000. mweec = 67041 uvoc 9001*0 nnnou .620 01 74 610001 unDo pnooin Ilnumno .12.n . 77 10r 174OC moult Ifl00fl .1*0 00 011Do 2770* 902046 170w. 20* '77 100*00) mIne 70*0alu 171w. mn* no now amv.c PO*0Do I-e4 .17* on 00w) 2000* 16170) 2aV.0 #000iln 1,1w. .17* 7W now 10002* mAle term 20* .0 40w) (*002* #0*1*04 1*011*0 *0* .04 100w) (*0020 p80,0010 -1. 204 - no @POTffR- The Symbol of Firoteclion DIMENSIONS INCHES (mm) FIG. I BELLS - FIG,2 WFATHFRPPQOFRAcaCRnY - BOXHnSONEThREADEDI,2cONDU1FENTR6NcR IQi • L. Ile 0110. 1770-2 FIG.3 WIRING (REAR VIEW) D.C. BELLS (oBSERvE POLARItY) A.C. SELLS -:- -. 1.on1*010( narY no .0166 USIS. 6. 001000 a.c. 000*1* ewwele moo elm one 2.1006105 reverE C 0*0(1100* S 6101 *0 4&C0110E (.4 2. eO-or-ure 1el 6 roar ocenwe 00 1.8. BUM owe. #776-3 INSTALLATION The bet shall be installed in accordance with NFPA 72 or local AIr]. The top of the device shall be no less than 90Aff and not less than 6" below the ceiling. Removethegong. Connect wiring (see Fig. 3), Mount bell mechanism to backbox (bell mechanism must be mounted with the striker pointing down). Reinstall the gong (be sure that the gong positioning pin, in the mechanism housing. is in the hole in the gong). Test all belts for proper operation and observe that they can be heard where requimd (bells must be heard in all areas as designated by the authority having jurisdiction). P010•IEO IS USA M1CC08850001.REvS PAGE20F2 rE8.01Ia0770.Sl05 Max. Horizontal Load Parallel 300 thru 900 2765 PerpendIcular 300 thru 900 2765 .. oá LI ' L.' L/ L/ P.O. Box 3365 South El Monte, CA 91733 626,444.0541 Fax 626.444.3887 www. Afcon.org 6• 411 SIZE - 1/2" bolt. MATERIAL - Carbon Steel or Ductile (Pictured). FINISH - Plain or E.G. PATENT - No. 6,629,678, LISTING/APPROVAL - C®US 203A-EX 2625, 203-EX 2551 OSHPD See USffr FUNCTION. - Sway brace adapter foi an AFCON sway brace assembly Designed to attach to the vertical or horizontal flange of a steel struc Additionally listed as an 6" hanger attachment. INSTALLATION - Per these lnstrutlons including N'FPA 13. Load rating -. see chart. . Combine with proper AFCON components-see disclaimer below. The structural members design will dictate speific attachment critei'i... ASSEMBLY - See draWing. . .. . . Install set bolts finger tight, then additionally tighten 1/2 turn of torque to 40 lb-ft Only tighten set-bolt with hand tools. . NEVER INSTALL SET BOLT WITH IMPACT/DRILL DRIVER. Attach AFCON sway brace assembly with 1/2" bolt. FEATURES • . * Design conforñis to angular geometry at panel point. * Fits 1/2" max, flange thickness. •• ORDERING- Part # and finish. Specific 4FCOiYprcdoctu ore exclusively designed to be compatible ONLY will, oiher.'IFCON products including ports and fno,cnnr,, resulting inn listed sway brace, restrainer or hongcr assembly.Be advised the following warranty restriction will nPI)IY. DISCLAIMER . AFCON will NOT worrinu against the failure or its products when used in combination will, oilier products, pnrtn on oyolctns not otoni,loclurcd or sold by AFCON, AFCON shall NOT be liable under any cir00000l0000, whatsoever for any direct or indirect, incldcolnl or consequential damages omnity kind, including but not limited to loss of business or profit, when nen.4FCONproduci, have been, or ore used. 1/15 P.O. Box 3365 South El Monte, CA 91.733 626.444.0541 Fax 626.444.3887 www. Afcon.org 411 SWAY BCE FITTING Part #077......,,. SIZE- SYSTEM PIPE: Nominal Pipe. Size Sch. 40 Steel 1" - 12" Sch. 10 Steel 1 1/4" - 12" Sch, 7 Steel 2-6" MATERIAL - Carbon Steel or S.S. (Type 304) FINISH - Plain or E.G. PATENT - No. 7,140,579 LISTING/APPROVAL. c®u 203A-EX 2625 ' FM Approved - 1950 torso FUNCTION - Longitudinal fitting of anAFCON sway brace assembly. INSTALLATION - Per these instructions including NFPA 13 or FM 2-8 Loadrating -see chart, ASSEMBLY - See drawing. . Combine with proper AFCON components- see disclaimer below. l.,,, ,,,.c,-.,l,.. t F. V /11 1 ' Max. Horizontal Load Li-1200 5"-10 2765 12 3740 0 Max. ASD Horizontal Load System NPS Sch. 30'44' 45'.59' 60'-74 75'90' 1-1 1/2 10-40 1070 420 510 570 2 LW-40 1570 1900 1730 1930 21/2-4 860 jQQ 110 10-40 1000 950 1150 1280 6" ET4O 1620 2220 2720 3040 8' TT" 2070 1 1250 1 1510 1690 fl11514 LlSU#V LLIS#LILL/¼'L JUL USL'_'i J La%.,v UI T LI LC%OICILGL I1Q.ttCO, .Tighte 1/2" bolts until fastcner flanges connect, FEATURES. .• 0 .., 0 * Patented -.design eliminates bending of fastener flanges during installation, * Patented — design preveolts over tightening on system pipe. * Improved assembly - fastener flanges connect for superior strength. * Visual .inspection -proper installation when 411 fastener flanges contact. ORDERING - Part #, size - system pipe and finish, Specitie AFCON products are exclusively designed lolw compatible ONLY with other AFCON products including parts and fasteners, resulting in a listed sway brace, rosiruluer or hunger ssseiiibly. Be advised the following warranty eextTteslun will pply• DlSCLAtMER. AFCQNwill NOT Warrant against he failure of Its products when used In combination with other products, potty or syStcos not manufactured or sold by AFCON. AFCON shalt NOT be liable under any eircwttstances whatsoever for any director indirect, Incidental or consequential damages of any bled, including but not Ua,ireui lobs, otbusluesa as'profii, when ,tos-AFCO/Vnnducts have bee,,, or can used, . ... 2/16 iZ?c :P.O. Box 3365 South El Monte, CA 917.33 626.444.0541 Fax 626.444.3867 www.Afcon.org 076 ' .1 ; •• ATTACHMENT FITTING UNIVERSAL LOCKING 17/32 STEEL BASE SIZE - BRACE PIPE: 1" thru 2 Sch. 40 MATERIAL - Ductile Iron and Carbon Steel.' FINISH -Plain or E.G.. . LISTING/APPROVAL--. . 203A-EX' 2625 OSHPD See Website, FUNCTION - Structure attachment fitting of an AFCON sway brace assembly. INSTALLATION - Per these instructions including NFPA 13, Load rating - see chart. Combine with properAFCON components- see diselimer below.. ASSEMBLY .,. .. •. Insert brace element into fitting snug against back of jaw, Install set bolt finger tight, then additionally tihten. 1/2 turns, or torque to 40 lb-ft. ____________________ Only tighten set bolt with hand tooli.. " . . ' Max Horizontal Load NEVER'INSTALL SET BOLT WITH IMPACT/DRILL DRIVER. FEATURES 300 thru 900 2765 * Swivel allows attachment at any angle. * Larger fastener hole avai1tble... Consult factory. ORDERING Part #, size brace pipe, material and finish = Speellic AFCQNprodocts ore exclusively designed to be competible ONLY with other AFCON products including parts and fosretrers, resulting In a listed sway brace, restrainer or hunger assembly. Be advised the following sysrruttty restriction will apply. DISCLAIMER . 4FCONwill NOT \vsrrurtt against the failure of its products when used in combinution with olhcrproducts, ports or systems not manufactured or sold by itFCON. ,SFCON shall NOT be linblu under any circumstances whatsoever for any director Indirect, incidental or eoitsectuentinl lintiledlo Inns of business or prol'tt, wltert rtoo..'IFCOrY products hove been, or sen used, damages of any kind, including bat nm 1/15 . . . . ' P.O. Box. 3365 South El Monte, CA 91733 626.4440541 Fax 626.444.3887 www.Afcon.org 035 ..SWAY B..,CE,FITTING MODEL I thru 4 inch pipe 31/2 &5 thru 12 ii°ch pipe SIZE - SYSTEM PIPE: Nönina1 Pipe Size Steel 1" thi-u 12" * Steel Specially listed - see chart. CPVC 1" thru 3". Brace common O.D. - Copper, Plastic, FRP SIZE - BRACE PIPE: I" thru 2" Sch. 40 Mm. 11/4" required. for 12" system pipe MATERIAL -Carbon steel and ductile iron. . . FINISH - Plain or E.G. PATENTS - No, 7,516,922 i No. 7,523,895 LISTING/APPROVAL - 203A EX 2625 551150 FM Approved - 1950 OSHPD 'See Website. FUNCTION - Lateral fitting of an AFCON sway brace assembly. INSTALLATION - Per these instructions including NFPA 13 or FM 2-8 and CPVC manufacturers instructions. Load ratings - see charts. ASSEMBLY- See drawing. Combine with proper AFCON components-. see disclaimer below. Insert brace' pipe through bores to achieve minimum 1" extension. Tighten 035 set screws until heads bottom out. FEATURES . . . *.Patented - designed for system pipe of varying material. * Improved assembly extra large bore for brace pipe. * Visual inspection, verifies proper installation, ORDERING - Part #, size -system pipe, size - brace pipe and finish. ' Max. Horizontal Load System Sch. 30'-44' 45'.59'. 60'-85' 90' 1" 10-40 1 1 383 1956 2394 2765 1 1/4-2 ..fi40._1383 ,.1956 2394 27 2 1/2' - 4" 7a40_ 133 19.. 2394 2765 A" - A" 740.. 12.83. J.9. 22 2L6.. 8" 1040 1383 1958 2394 2765 10" 1040 1363 1956 2394 2765 12" 10-40 1870 '4 3238 740 43 Max. ASO Horizontal Load syst si°s 5th. 30"44' 45'59' 60'•74 75'.90' 1"- 11/2' 7-40 1680 2380 2920 3250 2-3" 7-40 1800 2350 3120 3490 4" 7-40 1370 19302370 2640 5", 6", 8" 7-40 730 1040 1270 1420 Special Note: Thin wall sprinklerpipe has a propensity for damage to its circuthference resulting. in egging. When- egging. exists -shift mounting location, • SpecilicAFCON products are exclusively designed lobe compatible ONLY with other AFCON products Including parts and Fasteners, resulting Ins haled away bruce, restrainer or hunger assembly. Be advised the following warranty restriction will apply. DISCLAIMER AFCONwiil NOT wsenOni against she failure of its products when used in combination with other products, parts or sysieuis not ,nasrdfnclrsred or sold Is)i AFCON. 4FCONsisalltNOT be liable under any eiresjnslsnees whatsoever for any director indirect, incidental or consequential damages of any kind, including but not belted in loss of business or profit, when nos-AFCOiV products hove been, or are used, 8/16 1tEE FFC 20, 9 -oS1 HAD LEY ENGINEERING November 30, 2018 DA WHITACRE CONSTRUCTION David Blackston 1108 Greenfield Drive El Cajon, CA 92021 Subject: Reynolds Lot 20 Carlsbad, CA Seyco Project No.: W704-18 HE Project No. 18-124 The pre-fabricated steel joists for this project have been designed in accordance with the 2016 California Building Code, using the loads provided by the Engineer of Record. The loading included general uniform sprinkler loading. Additionally, the joists have been designed as per the sprinkler drawings by Epic Fire Protection, Inc. dated 09/26/2018. Thank you for the opportunity to assist you in this matter. If you have any questions, please contact us. Sincerely, Thomas W. Hadley Hadley Engineering, Inc. Thomas W. Hadley, S.E. W. No.S 5697 Exp. 6-30-19 pr 6w 11/30/2018 34159 Yucaipa Boulevard, Suite C, Yucaipa, CA 92399 (909) 446-0712 www.hadleyengineering.com Page 1 .'-- MEXICALI November 5, 2018 DA WHITACRE CONTRUCTION 1108 GREENFIELD DR EL CAJON, CA 92021 Project: REYNOLDS LOT 20 CARLSBAD, CA Regarding: SPRINKLER LOADS SUPPORTED FROM JOISTS To whom it may concern, The joist design complies with Chapter 16 of the 2016 CBC in the sense that we have designed the joists/girders for loads provided by design engineer of record and provided loading to accommodate sprinkler mains, which exceed already included loads in General Structural Notes on sheet SO. 1, and braces as provided and shown on the approved Seyco placement plans. Referenced sprinkler and brace loads were provided on Epic Fire Protection drawings dated 8-21-18. Placement of the loads in the field need to occur at panel points or be reinforced per "Reinforcing Detail" on Sheet J 1 of 2 consistent with The SJI Code of Standard Practice. Regards, Troy Olsen SEYCO JOIST COMPANY 2025 N CENTRAL AVE. * BROWNSVILLE * TX * 78521 * PHONE 909 660 0112 troy@seycojoist.com