Loading...
HomeMy WebLinkAbout5781 VAN ALLEN WAY; ; AS080145; PermitCity ot Carlsbad Sprinkler Permit Permit No: AS080145 5781 VAN ALLEN Job Address: WY Permit Type: SPRINK Parcel No: 2121304400 Lot #: 0 Status: ISSUED Applied 9/5/2008 Approved: 9/5/2008 Reference No.: Issued: 9/5/2008 PC #: Inspector: Project Title: INVITROGEN TI FIRE SPRINKLER PLAN CHECK & INSPECTIONS Applicant: WESTERN FIRE PROTECTION 13630 DANIELSON ST. P0 WAY CA 858-513-4949 Owner: GRIFFIN CAPITAL CARLSBAD POINTE, INVESTORS L L C C/O INVITROGEN CORPORATION 1600 FARADAY AVE CARLSBAD CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 130 0 130 0 WESTERN FIRE PROTECTION, INC. 13630 DANIELSON STREET POWAY,CA 92064 HYDRAULIC CALCULATIONS FOR INVITROGEN CP-13 5781 VAN ALLEN WAY CARLSBAD, CA 92008 FILE NUMBER: DATE: SEP 3, 2008 -DESIGN DATA- LABORATORY OCCUPANCY CLASSIFICATION: DENSITY: AREA OF APPLICATION: COVERAGE PER SPRINKLER: NUMBER OF SPRINKLERS CALCULATED: TOTAL SPRINKLER WATER FLOW REQUIRED: TOTAL WATER REQUIRED (including hose) FLOW AND PRESSURE (@ BOR): SPRINKLER K-FACTOR: NAME OF CONTRACTOR: DESIGN/LAYOUT BY: AUTHORITY HAVING JURISDICTION: CONTRACTOR CERTIFICATION NUMBER: ORD. II .2 gpm/sq. ft. 1540 sq. ft. 130 max sq. ft. 25 sprinklers 591.2 gpm 841.2 gpm 591.2 gpm 8 96.0 psi 5.6 WESTERN FIRE PROTECTION D. OLIVAS CARLSBAD FIRE DEPT C16-588039 CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE # 50040828 HRS SYSTEMS, INC. TUCKER, GA 30084 TUCKER, GA 30084 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 9/3/20082466 INVITROGEN AREA 10 TXDX\CALCULATIONS\SUBMITTED\LAB.SDF JOB TITLE: LAB WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ!D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) SOURCE 117.0 112.5 1185.0 114.6 841.2 111.8 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 841.2 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 250.0 GPM OTHER HOSE STREAM ALLOWANCES 0.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 591.2 GPM NODE ANALYSIS DATA DENSITY NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE AREA REQ. ACT. (FT) (PSI) (GPM) (FT-2) (GPM/FT"2) Si 11.0 K= 5.60 9.7 17.4 75.0 0.200 0.232 1 13.0 - - - - 9.5 --- S2 10.8 K= 5.60 9.5 17.3 75.0 0.200 0.230 2 13.0 - - - - 9.8 --- 3 13.0 - - - - 10.3 --- S4 11.0 K= 5.60 13.8 20.8 75.0 0.200 0.277 4 13.0 - - - - 13.9 --- 5 13.0 - - - - 14.2 --- S6 11.0 K= 5.60 15.2 21.8 75.0 0.200 0.291 6 13.0 - - - - 15.7 --- 7 13.0 - - - - 18.5 --- S8 11.0 K= 5.60 18.6 24.2 75.0 0.200 0.322 8 13.0 - - - - 19.5 --- S9 11.0 K= 5.60 24.4 27.7 75.0 0.200 0.369 9 13.0 - - - - 25.7 --- 10 13.0 - - - - 28.2 - - - Sli 11.0 K= 5.60 33.5 32.4 75.0 0.200 0.432 11 13.0 - - - - 35.5 --- 12 13.0 - - - - 40.8 --- 13 13.0 - - - - 42.6 --- 14 13.0 - - - - 44.0 --- S15 10.8 K= 5.60 39.0 35.0 75.0 0.200 0.466 15 13.0 - - - - 41.9 --- S16 10.8 K= 5.60 7.2 15.0 75.0 0.200 0.200 16 13.0 - - - - 7.0 --- S17 11.0 K= 5.60 7.9 15.7 75.0 0.200 0.210 17 13.0 - - - - 7.4 --- S18 11.0 K= 5.60 10.4 18.1 75.0 0.200 0.241 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 9/3/20082466 INVITROGEN AREA 10 TXDX\CALCULATIONS\SUBMITTED\LAB.SDF JOB TITLE: LAB NODE ANALYSIS DATA DENSITY NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE AREA REQ. ACT. (PT) (PSI) (GPM) (FT A2) (GPM/FT"2) 18 13.0 - - - - 10.0 --- S19 11.0 K= 5.60 11.0 18.6 75.0 0.200 0.247 19 13.0 - - - - 11.5 --- S20 11.0 K= 5.60 13.6 20.6 75.0 0.200 0.275 20 13.0 - - - - 14.3 --- S21 11.0 K= 5.60 17.0 23.1 75.0 0.200 0.308 21 13.0 - - - - 18.1 --- S22 11.0 K= 5.60 23.7 27.3 75.0 0.200 0.364 22 13.0 - - - - 25.6 --- S23 11.0 K= 5.60 27.6 29.4 75.0 0.200 0.392 23 13.0 - - - - 29.8 --- S24 11.0 K= 5.60 32.2 31.8 75.0 0.200 0.424 24 13.0 - - - - 33.4 --- S25 10.8 K= 5.60 36.6 33.9 75.0 0.200 0.452 25 13.0 - - - - 39.0 --- 26 13.0 - - - - 39.3 --- S27 11.0 K= 5.60 10.3 18.0 75.0 0.200 0.240 27 13.0 - - - - 11.0 --- S28 11.0 K= 5.60 12.0 19.4 75.0 0.200 0.259 28 13.0 - - - - 12.3 --- 29 13.0 - - - - 14.4 --- S30 11.0 K= 5.60 13.8 20.8 75.0 0.200 0.278 30 13.0 - - - - 15.3 --- 31 13.0 - - - - 15.5 --- S32 11.0 K= 5.60 15.4 22.0 75.0 0.200 0.293 32 13.0 - - - - 17.1 --- 33 13.0 - - - - 18.4 --- S34 11.0 K= 5.60 18.9 24.3 75.0 0.200 0.324 34 13.0 - - - - 21.1 --- 35 13.0 - - - - 23.4 --- S36 11.0 K= 5.60 23.5 27.1 75.0 0.200 0.362 36 13.0 - - - - 26.4 --- S37 11.0 K= 5.60 27.9 29.6 75.0 0.200 0.394 37 13.0 - - - - 31.5 --- 38 13.0 - - - - 31.8 - - - Ml 13.0 - - - - 46.4 --- M2 13.0 - - - - 46.5 --- M3 13.0 - - - - 47.1 --- M4 13.0 - - - - 49.9 - - - MS 13.0 - - - - 62.2 --- M6 13.0 - - - - 79.1 --- M7 29.0 - - - - 76.7 --- M8 29.0 - - - - 83.7 - - - TOR 29.0 - - - - 84.3 - - - BOR 3.0 - - - - 96.0 --- UG1 0.5 - - - - 97.2 - - - SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 I DATE: 9/3/20082466 INVITROGEN AREA 10 TXDX\CALCULATIONS\SUBMITTED\LAB.SDF JOB TITLE: LAB NODE ANALYSIS DATA DENSITY NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE AREA REQ. ACT. (FT) (PSI) (GPM) (FT-2) (GPM/FT"2) UG2 -3.0 - - - - 98.8 --- UG3 -3.0 - - - - 99.1 --- BF1 3.0 - - - - 96.6 --- BF2 3.0 - - - - 108.6 --- UG4 -3.0 - - - - 111.4 - - - SOURCE -3.0 SOURCE 111.8 591.2 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 9/3/20082466 INVITROGEN AREA 10 TXDX\CALCULATIONS\SUBMITTED\LAB.SDF JOB TITLE: LAB PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 -17.4 1.080 PL 3.33 PF 0.7 51 11.0 5.6 9.7 17.4 6.1 120 FTG 2E PE -0.9 1 13.0 0.0 9.5 0.0 0.088 TL 7.94 PV Pipe: 2 -17.4 1.080 PL 2.83 PF 0.2 1 13.0 0.0 9.5 0.0 6.1 120 FTG ---- PE 0.0 2 13.0 0.0 9.8 0.0 0.088 TL 2.83 PV Pipe: 3 -17.3 1.080 PL 5.82 PF 1.2 S2 10.8 5.6 9.5 17.3 6.0 120 FTG ET PE -0.9 2 13.0 0.0 9.8 0.0 0.086 TL 13.89 PV Pipe: 4 -34.7 1.080 PL 1.79 PF 0.6 2 13.0 0.0 9.8 0.0 12.2 120 FTG ---- PE 0.0 3 13.0 0.0 10.3 0.0 0.313 TL 1.79 PV Pipe: 5 -34.7 1.080 PL 5.70 PF 3.6 3 13.0 0.0 10.3 0.0 12.2 120 FTG T PE 0.0 4 13.0 0.0 13.9 0.0 0.313 TL 11.46 PV Pipe: 6 -20.8 1.080 PL 3.83 PF 1.0 S4 11.0 5.6 13.8 20.8 7.3 120 FTG 2E PE -0.9 4 13.0 0.0 13.9 0.0 0.121 TL 8.44 PV Pipe: 7 -55.5 1.408 PL 1.16 PF 0.2 4 13.0 0.0 13.9 0.0 11.4 120 FTG ---- PE 0.0 5 13.0 0.0 14.2 0.0 0.205 TL 1.16 PV Pipe: 8 -55.5 1.408 PL 7.50 PF 1.5 5 13.0 0.0 14.2 0.0 11.4 120 FTG ---- PE 0.0 6 13.0 0.0 15.7 0.0 0.205 TL 7.50 PV Pipe: 9 -21.8 1.080 PL 2.50 PF 1.4 S6 11.0 5.6 15.2 21.8 7.6 120 FTG ET PE -0.9 6 13.0 0.0 15.7 0.0 0.132 TL 10.57 PV Pipe: 10 -77.3 1.408 PL 7.50 PF 2.8 6 13.0 0.0 15.7 0.0 15.9 120 FTG ---- PE 0.0 7 13.0 0.0 18.5 0.0 0.378 TL 7.50 PV Pipe: 11 -77.3 1.408 PL 2.50 PF 0.9 7 13.0 0.0 18.5 0.0 15.9 120 FTG ---- PE 0.0 8 13.0 0.0 19.5 0.0 0.378 TL 2.50 PV I I I I I I I I I I I I I I I I I I I SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 9/3/20082466 INVITROGEN AREA 10 TXDX\CALCULATIONS\SUBMITTED\LAB.SDF JOB TITLE: LAB PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 12 -24.2 1.080 PL 2.50 PF 1.7 S8 11.0 5.6 18.6 24.2 8.5 120 FTG ST PE -0.9 8 13.0 0.0 19.5 0.0 0.160 TL 10.57 PV Pipe: 13 -101.4 1.408 PL 10.00 PF 6.3 8 13.0 0.0 19.5 0.0 20.9 120 FTG ---- PE 0.0 9 13.0 0.0 25.7 0.0 0.626 TL 10.00 PV Pipe: 14 -27.7 1.080 PL 2.50 PF 2.2 S9 11.0 5.6 24.4 27.7 9.7 120 FTG ET PS -0.9 9 13.0 0.0 25.7 0.0 0.206 TL 10.57 PV Pipe: 15 -129.1 1.408 PL 2.50 PF 2.4 9 13.0 0.0 25.7 0.0 26.6 120 FTG ---- PE 0.0 10 13.0 0.0 28.2 0.0 0.978 TL 2.50 PV Pipe: 16 -129.1 1.408 PL 7.50 PF 7.3 10 13.0 0.0 28.2 0.0 26.6 120 FTG ---- PS 0.0 11 13.0 0.0 35.5 0.0 0.978 TL 7.50 PV Pipe: 17 -32.4 1.080 PL 2.50 PF 2.9 Sil 11.0 5.6 33.5 32.4 11.3 120 FTG ET PS -0.9 11 13.0 0.0 35.5 0.0 0.276 TL 10.57 PV Pipe: 18 -161.5 1.639 PL 7.50 PP 5.3 11 13.0 0.0 35.5 0.0 24.6 120 FTG ---- PE 0.0 12 13.0 0.0 40.8 0.0 0.706 TL 7.50 PV Pipe: 19 -161.5 1.639 PL 2.50 PP 1.8 12 13.0 0.0 40.8 0.0 24.6 120 FTG ---- PE 0.0 13 13.0 0.0 42.6 0.0 0.706 TL 2.50 PV Pipe: 20 -161.5 2.104 PL 6.70 PP 1.4 13 13.0 0.0 42.6 0.0 14.9 120 FTG ---- PE 0.0 14 13.0 0.0 44.0 0.0 0.209 TL 6.70 PV Pipe: 21 -161.5 2.104 PL 0.75 PP 2.4 14 13.0 0.0 44.0 0.0 14.9 120 FTG T PE 0.0 Ml 13.0 0.0 46.4 0.0 0.209 TL 11.65 PV Pipe: 22 -35.0 1.080 FL 7.58 PP 3.9 S15 10.8 5.6 39.0 35.0 12.2 120 FTG 2E PS -0.9 15 13.0 0.0 41.9 0.0 0.317 TL 12.19 PV Pipe: 23 -35.0 1.080 PL 8.79 PF 4.6 15 13.0 0.0 41.9 0.0 12.2 120 FTG T PE 0.0 M2 13.0 0.0 46.5 0.0 0.317 TL 14.55 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 7 DATE: 9/3/20082466 INVITROGEN AREA 10 TXDX\CALCULATIONS\SUBMITTED\LAB.SDF JOB TITLE: LAB PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 24 -15.0 1.080 PL 6.54 PF 0.7 S16 10.8 5.6 7.2 15.0 5.3 120 FTG 2E FE -0.9 16 13.0 0.0 7.0 0.0 0.066 TL 11.15 PV Pipe: 25 -15.0 1.080 FL 1.33 PF 0.5 16 13.0 0.0 7.0 0.0 5.3 120 FTG T FE 0.0 17 13.0 0.0 7.4 0.0 0.066 TL 7.09 PV Pipe: 26 -15.7 1.080 PL 3.45 PF 0.4 S17 11.0 5.6 7.9 15.7 5.5 120 FTG E FE -0.9 17 13.0 0.0 7.4 0.0 0.072 TL 5.75 PV Pipe: 27 -30.7 1.080 PL 8.04 PF 2.6 17 13.0 0.0 7.4 0.0 10.8 120 FTG E PE 0.0 18 13.0 0.0 10.0 0.0 0.250 TL 10.34 PV Pipe: 28 -18.1 1.080 PL 2.50 PF 0.5 S18 11.0 5.6 10.4 18.1 6.3 120 FTG E PE -0.9 18 13.0 0.0 10.0 0.0 0.094 TL 4.80 PV Pipe: 29 -48.8 1.408 FL 8.83 PF 1.4 18 13.0 0.0 10.0 0.0 10.1 120 FTG ---- FE 0.0 19 13.0 0.0 11.5 0.0 0.162 TL 8.83 PV Pipe: 30 -18.6 1.080 PL 3.33 PF 1.3 S19 11.0 5.6 11.0 18.6 6.5 120 FTG 2ET PE -0.9 19 13.0 0.0 11.5 0.0 0.098 TL 13.70 PV Pipe: 31 -67.4 1.408 PL 9.66 PF 2.8 19 13.0 0.0 11.5 0.0 13.9 120 FTG ---- PE 0.0 20 13.0 0.0 14.3 0.0 0.294 TL 9.66 PV Pipe: 32 -20.6 1.080 PL 3.00 PF 1.6 S20 11.0 5.6 13.6 20.6 7.2 120 FTG 2ET FE -0.9 20 13.0 0.0 14.3 0.0 0.119 TL 13.37 PV Pipe: 33 -88.0 1.408 PL 8.00 PF 3.8 20 13.0 0.0 14.3 0.0 18.1 120 FTG ---- FE 0.0 21 13.0 0.0 18.1 0.0 0.481 TL 8.00 PV Pipe: 34 -23.1 1.080 PL 3.00 PF 2.0 S21 11.0 5.6 17.0 23.1 8.1 120 FTG 2ET FE -0.9 21 13.0 0.0 18.1 0.0 0.148 TL 13.37 PV Pipe: 35 -111.1 1.408 PL 10.00 PF 7.4 21 13.0 0.0 18.1 0.0 22.9 120 FTG ---- FE 0.0 22 13.0 0.0 25.6 0.0 0.741 TL 10.00 PV I I SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 8 DATE: 9/3/20082466 INVITROGBN AREA 10 TXDX\CALCULATIONS\SUBMITTBD\LAB.SDF JOB TITLE: LAB PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 36 -27.3 1.080 PL 3.00 PF 2.7 S22 11.0 5.6 23.7 27.3 9.6 120 FTG 2ET PE -0.9 22 13.0 0.0 25.6 0.0 0.201 TL 13.37 PV Pipe: 37 -138.4 1.639 PL 8.00 PF 4.2 22 13.0 0.0 25.6 0.0 21.0 120 FTG ---- PE 0.0 23 13.0 0.0 29.8 0.0 0.531 TL 8.00 PV Pipe: 38 -29.4 1.080 PL 3.00 PF 3.1 S23 11.0 5.6 27.6 29.4 10.3 120 FTG 2ET PE -0.9 23 13.0 0.0 29.8 0.0 0.230 TL 13.37 PV Pipe: 39 -167.8 2.104 PL 5.00 PF 3.6 23 13.0 0.0 29.8 0.0 15.5 120 FTG T PE 0.0 24 13.0 0.0 33.4 0.0 0.225 TL 15.90 PV Pipe: 40 -31.8 1.080 PL 3.00 PF 2.0 S24 11.0 5.6 32.2 31.8 11.1 120 FTG 2E PE -0.9 24 13.0 0.0 33.4 0.0 0.266 TL 7.61 PV Pipe: 41 -199.6 2.104 PL 8.16 PF 5.9 24 13.0 0.0 33.4 0.0 18.4 120 FTG T PE 0.0 26 13.0 0.0 39.3 0.0 0.309 TL 19.06 PV Pipe: 42 -33.9 1.080 PL 6.66 PF 3.4 S25 10.8 5.6 36.6 33.9 11.9 120 FTG 2E PE -0.9 25 13.0 0.0 39.0 0.0 0.299 TL 11.27 PV Pipe: 43 -33.9 1.080 PL 0.83 PF 0.2 25 13.0 0.0 39.0 0.0 11.9 120 FTG ---- PE 0.0 26 13.0 0.0 39.3 0.0 0.299 TL 0.83 PV Pipe: 44 -233.5 2.104 PL 7.95 PF 7.8 26 13.0 0.0 39.3 0.0 21.5 120 FTG T PE 0.0 M3 13.0 0.0 47.1 0.0 0.414 TL 18.85 PV Pipe: 45 -18.0 1.080 PL 6.08 PF 1.5 S27 11.0 5.6 10.3 18.0 6.3 120 FTG 2ET PE -0.9 27 13.0 0.0 11.0 0.0 0.093 TL 16.45 PV Pipe: 46 -18.0 1.080 PL 8.33 PF 1.3 27 13.0 0.0 11.0 0.0 6.3 120 FTG T PE 0.0 28 13.0 0.0 12.3 0.0 0.093 TL 14.09 PV Pipe: 47 -19.4 1.080 PL 6.41 PF 1.2 S28 11.0 5.6 12.0 19.4 6.8 120 FTG 2E PE -0.9 28 13.0 0.0 12.3 0.0 0.107 TL 11.02 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 9 DATE: 9/3/20082466 INVITROGEN AREA 10 TXDX\CALCULATIONS\SUBMITTED\LAB.SDF JOB TITLE: I LAB PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. I END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) • Pipe: 48 -37.4 1.080 PL 3.45 PF 2.1 28 13.0 0.0 12.3 0.0 13.1 120 FTG E PE 0.0 29 13.0 0.0 14.4 0.0 0.360 TL 5.75 PV I Pipe: 49 -37.4 1.408 PL 8.87 PF 0.9 - 29 13.0 0.0 14.4 0.0 7.7 120 FTG ---- PE 0.0 30 13.0 0.0 15.3 0.0 0.099 TL 8.87 PV I Pipe: 50 -20.8 1.080 PL 8.75 PF 2.3 S30 11.0 5.6 13.8 20.8 7.3 120 FTG 2ET PE -0.9 I 30 13.0 0.0 15.3 0.0 0.122 TL 19.12 PV Pipe: 51 -58.2 1.408 PL 1.20 PF 0.3 30 13.0 0.0 15.3 0.0 12.0 120 FTG ---- PE 0.0 I 31 13.0 0.0 15.5 0.0 0.224 TL 1.20 PV Pipe: 52 -58.2 1.408 PL 6.79 PF 1.5 31 13.0 0.0 15.5 0.0 12.0 120 FTG ---- PE 0.0 P 32 13.0 0.0 17.1 0.0 0.224 TL 6.79 PV • Pipe: 53 -22.0 1.080 PL 8.75 PF 2.6 I S32 11.0 5.6 15.4 22.0 7.7 120 FTG 2ET PE -0.9 32 13.0 0.0 17.1 0.0 0.134 TL 19.12 PV • Pipe: 54 -80.2 1.408 PL 3.29 PF 1.3 32 13.0 0.0 17.1 0.0 16.5 120 FTG ---- PE 0.0 33 13.0 0.0 18.4 0.0 0.405 TL 3.29 PV Pipe: 55 -80.2 1.408 PL 6.70 PF 2.7 33 13.0 0.0 18.4 0.0 16.5 120 FTG ---- PE 0.0 34 13.0 0.0 21.1 0.0 0.405 TL 6.70 PV I Pipe: 56 -24.3 1.080 PL 8.75 PF 3.1 S34 11.0 5.6 18.9 24.3 8.5 120 FTG 2ET PE -0.9 I 34 13.0 0.0 21.1 0.0 0.162 TL 19.12 PV Pipe: 57 -104.5 1.408 PL 3.41 PF 2.3 34 13.0 0.0 21.1 0.0 21.5 120 FTG ---- PE 0.0 35 I 13.0 0.0 23.4 0.0 0.661 TL 3.41 PV Pipe: 58 -104.5 1.408 PL 4.62 PF 3.1 I 35 13.0 0.0 23.4 0.0 21.5 120 FTG ---- PE 0.0 36 13.0 0.0 26.4 0.0 0.661 TL 4.62 PV • Pipe: 59 -27.1 1.080 PL 8.75 PF 3.8 S36 11.0 5.6 23.5 27.1 9.5 120 FTG 2ET PE -0.9 36 13.0 0.0 26.4 0.0 0.199 TL 19.12 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 10 DATE: 9/3/20082466 INVITROGEN AREA 10 TXDX\CALCULATIONS\SUBMITTED\LAB.SDF JOB TITLE: LAB PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 60 -131.7 1.408 PL 5.00 PF 5.1 36 13.0 0.0 26.4 0.0 27.1 120 FTG ---- PE 0.0 37 13.0 0.0 31.5 0.0 1.014 TL 5.00 PV Pipe: 61 -29.6 1.080 PL 8.75 PF 4.5 S37 11.0 5.6 27.9 29.6 10.4 120 FTG 2ET PE -0.9 37 13.0 0.0 31.5 0.0 0.233 TL 19.12 PV Pipe: 62 -161.2 1.639 PL 0.50 PF 0.4 37 13.0 0.0 31.5 0.0 24.5 120 FTG ---- PE 0.0 38 13.0 0.0 31.8 0.0 0.704 TL 0.50 PV Pipe: 63 -161.2 1.639 PL 8.24 PF 18.1 38 13.0 0.0 31.8 0.0 24.5 120 FTG 2ET PE 0.0 M4 13.0 0.0 49.9 0.0 0.704 TL 25.69 PV Pipe: 64 -161.5 3.314 PL 5.87 PF 0.1 Ml 13.0 0.0 46.4 0.0 6.0 120 FTG ---- PE 0.0 M2 13.0 0.0 46.5 0.0 0.023 TL 5.87 PV Pipe: 65 -196.5 3.314 PL 15.95 PF 0.5 M2 13.0 0.0 46.5 0.0 7.3 120 FTG ---- PE 0.0 M3 13.0 0.0 47.1 0.0 0.033 TL 15.95 PV Pipe: 66 -430.0 3.314 PL 10.25 PF 2.9 M3 13.0 0.0 47.1 0.0 16.0 120 FTG E PE 0.0 M4 13.0 0.0 49.9 0.0 0.140 TL 20.44 PV Pipe: 67 -591.2 3.314 PL 28.16 PF 12.3 M4 13.0 0.0 49.9 0.0 22.0 120 FTG 2E PE 0.0 M5 13.0 0.0 62.2 0.0 0.252 TL 48.54 PV Pipe: 68 -591.2 3.314 PL 46.45 PF 16.9 M5 13.0 0.0 62.2 0.0 22.0 120 FTG 2E PE 0.0 M6 13.0 0.0 79.1 0.0 0.252 TL 66.83 PV Pipe: 69 -591.2 4.310 EL 23.50 PF 4.6 146 13.0 0.0 79.1 0.0 13.0 120 FTG ET PE -6.9 M7 29.0 0.0 76.7 0.0 0.070 TL 65.31 PV Pipe: 70 -591.2 4.310 EL 85.00 PF 6.9 147 29.0 0.0 76.7 0.0 13.0 120 FTG E PE 0.0 148 29.0 0.0 83.7 0.0 0.070 TL 98.94 PV Pipe: 71 -591.2 6.357 EL 40.00 PF 0.6 148 29.0 0.0 83.7 0.0 6.0 120 FTG E PE 0.0 TOR 29.0 0.0 84.3 0.0 0.011 TL 57.60 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 11 DATE: 9/3/20082466 INVITROGEN AREA 10 TXDX\CALCULATIONS\SUBMITTED\LAB.SDF JOB TITLE: LAB PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 72 -591.2 6.357 PL 26.00 PF 0.5 TOR 29.0 0.0 84.3 0.0 6.0 120 FTG E PE 11.3 BOR 3.0 0.0 96.0 0.0 0.011 TL 43.60 PV Pipe: 73 -591.2 8.249 PL 7.00 PF 0.1 BOR 3.0 0.0 96.0 0.0 3.5 120 FTG E PE 1.1 UG1 0.5 0.0 97.2 0.0 0.003 TL 28.14 PV Pipe: 74 -591.2 8.510 PL 9.00 PF 0.1 UG1 0.5 0.0 97.2 0.0 3.3 140 FTG E PE 1.5 UG2 -3.0 0.0 98.8 0.0 0.002 TL 41.72 PV Pipe: 75 -591.2 7.987 PL 130.00 PF 0.4 UG2 -3.0 0.0 98.8 0.0 3.8 150 FTG E PE 0.0 UG3 -3.0 0.0 99.1 0.0 0.002 TL 157.30 PV Pipe: 76 -591.2 8.510 PL 6.00 PF 0.1 UG3 -3.0 0.0 99.1 0.0 3.3 140 FTG E PE -2.6 BF1 3.0 0.0 96.6 0.0 0.002 TL 38.72 PV Pipe: 77 FIXED PRESSURE LOSS DEVICE BF2 3.0 0.0 108.6 0.0 12.0 psi, 591.2 gpm BF1 3.0 0.0 96.6 0.0 Pipe: 78 -591.2 8.510 PL 6.00 PF 0.2 BF2 3.0 0.0 108.6 0.0 3.3 140 FTG ET PE 2.6 UG4 -3.0 0.0 111.4 0.0 0.002 TL 102.35 PV Pipe: 79 -591.2 7.987 PL 136.00 PF 0.4 UG4 -3.0 0.0 111.4 0.0 3.8 150 FTG TG PE 0.0 SOURCE -3.0 SRCE 111.8 (N/A) 0.002 TL 195.15 PV NOTES (HASS) Calculations were performed by the HASS 7.9 computer program under license no. 50040828 granted by HRS Systems, Inc. 4792 LaVista Road Tucker, GA 30084 The system has been calculated to provide an average imbalance at each node of 0.001 gpm and a maximum imbalance at any node of 0.084 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 27.1 ft/sec at pipe 60. I SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 12 DATE: 9/3/20082466 INVITROGEN AREA 10 TXDX\CALCULATIONS\SUBMITTED\LAB.SDF JOB TITLE: I LAB (4) PIPE FITTINGS TABLE I Pipe Table Name: STANDARD.PIP PAGE: * MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) I E T L C B G A D N Eli Tee LngEfl ChkViv BfyViv GatViv AlmChk DPViv NPTee 1.080 2.30 5.76 2.30 5.76 6.91 1.15 11.52 11.52 5.76 I 1.408 3.31 6.62 2.21 7.72 6.62 1.10 11.03 11.03 6.62 1.639 4.36 8.73 2.18 9.82 6.54 1.09 10.91 10.91 8.73 2.104 5.45 10.90 3.27 11.99 6.54 1.09 10.90 10.90 10.90 3.314 10.19 21.84 7.28 23.29 14.56 1.46 18.93 18.93 21.84 4.310 I 13.94 27.87 8.36 30.66 16.72 2.79 27.87 27.87 27.87 6.357 17.60 37.72 11.32 40.23 12.57 3.77 35.21 35.21 37.72 7.987 18.07 35.13 13.05 45.16 12.04 4.01 31.11 31.11 35.13 8.249 I 21.14 41.11 15.27 52.85 14.09 4.70 36.41 36.41 41.11 8.510 24.60 47.84 17.77 61.51 16.40 5.47 42.37 42.37 47.84 0 0 00 0 -1 0 0 (N 0 0 0 0 0 0 0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 13 DATE: 9/3/20082466 INVITROGEN AREA 10 TXDX\CALCULATIONS\SUBMITTED\LAB.SDF JOB TITLE: LAB 0 0 0 (N C) 0 0 0 0 (D 0 (N C) 0 C) Li) (N Oc) —Qu-r-1--- SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 14 DATE: 9/3/20082466 INVITROGEN AREA 10 TXDX\CALCULATIONS\SUBMITTED\LAB.SDF JOB TITLE: LAB WATER SUPPLY CURVE 120+ *\\\\\\\\\\\\ I 0\\\\\\\\\\\ I X * <-112.5 psi @ 1185 gpm 110+ Flow Test Point 100+ 90+ P 80+ R I E I S I 5 70+ U I R E I 60+ P I S I I 50+ 40+ 30+ 20+ LEGEND U I X = Required Water Supply I 111.84 psi @ 841.2 gpm 10+ I 0 = Available Water Supply I 114.61 psi 8 841.2 gpm I, 0++-+---+----+-----+ ------+ --------+ --------+ ---------+ -----------+ DynamThread 0 Full Line Sch-40 Replacement Dyna-Thread' offers the life expectancy of Sch40 with superior hydraulics and greater value. Dyna-Thread sprinkler pipe represents an engineering advancement for the sprinkler pipe industry. It combines the safety and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages. Dyna-Thread's inside diameter is up to 3.6% larger than Sch-40 giving it superior hydraulics. And, when used in combination with Dyna-Flow pipe, down sizing often occurs. Dyna-Thread is fully listed and approved by UL, ULC, and FM for fire sprinkler applications. The life expectancy of Dyna-Thread and Sch40 are equal based on the calculated wall thicknesses per UL. The consistent quality of steel used to make Dyna-Thread facilitates smooth threading and lower maintenance costs. The exterior of Dyna-Thread is protected by a clean, durable mill coating for extended shelf life and easy paint application. V <~> (~~ Listed Approved Listed With its increased strength and lighter weight, Dyna-Thread reduces installation fatigue and is ideal for retro-fit applications. the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed thread, assumed to be the weakest point of the pipe length. Dyna- Thread and Sch-40 have the same calculated wall thicknesses at this point and are both assigned the same CRIR of 1.00. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial Formula, "ABF". In scientific laboratory test, ABS proved to have superior resistance to microbial colonization of pipe walls, thereby delaying or possibly preventing the onset of Microbiologically Influenced corrosion (MlC) when the First Sprinkler System is first installed. More wall thickness at the thread (CRR=l .00) gives Dyna-Thread better life expectancy than light-wall threadable pipe joints. warning. Dyna-Thread is approved for standard hanger spacing (15 ft. O.C.), can be used as earthquake sway bracing, and is safe to use as drops. Dyna-Thread is safer to weld on. Dyna-Thread is more widely accepted than lightwall threadable where Sch-40 is specified. Super 40fDyna-Thread pipe is manufactured to meet: ASTM A-13 5, Grade A and is in compliance with NFPA-13. All sizes of Super 40/Dyna- Thread are rated at 300 psi working pressure. Super 40/Dyna-Thread is UL and ULC Listed for wet, dry deluge and pre-action sprinkler systems and FM Approved for use in wet systems. Super 40/Dyna-Thread can be "hot-dip" galvanized to meet FM requirement for dry systems. Super 40/Dyna-Thread is approved for all threaded couplings and welded outlets and is suitable for all roll-grooved, and plain-end fittings. (See listing information). Specifications NPS Nominal I.D. WI. WI. (1420 Filled) Pcs/ Wt/Lift (21) WtILifI (24) WtILitt (25') In; mm In; mm Lbs/Ft; Kg/rn Lbs/H; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg ill 1.080 1.330 1.75 70 1955 2234 2327 25 27.4 2.0 2.60 70 887 1013 105 11/4 1.408 1.870 2.54 51 2002 2288 2384 32 35.8 2.8 3.78 51 908 1038 1081 11/2' 1.639 2.290 3.22 44 2115 2418 2519 40 41.6 3.4 4.79 44 959 1097 114, 2' 2.104 3.050 4.57 30 1921 2196 2287 50 53.4 4.5 6.80 30 871 996 103 Corrosion Resistance Ratio (CRR) is a Unlike lightwall threadable pipe, UL (Underwriters Laboratory) term for Dyna-Thread has no thread gauge I tljCtl/Flow Control 16100 S. Lathrop Harvey, IL 60426 Customer Service: Qv- allied 11350 Norcom Rd. • Philadelphia, PA 19154 (800) 882-5543 TUBE &CONDUIT 2525 N. 27th Ave. Phoenix, AZ 85009 Fax 708-339-1806 S3-3 DynamFlowe High Strength Steel Pipe The original high-strength lightwall sprinkler pipe with hydraulics superior to Schedule-10. Dyna-Flow pipe is the "original" high- strength lightwall sprinkler pipe. Dyna- Flow has outstanding hydraulic capabilities and is recognized as the most popular alternative to Schedule-10 pipe. Lightweight, easy to cut and easy to handle for installation. Dyna-Flow is a valuable addition to any fire protection system. With an inside diameter of up to 11% larger than Schedule-40 and up to 7% larger than Schedule-10, Dyna-Flow pipe hydraulics are exceptional. Larger l.D.s enable Dyna-Flow, and related components, to be down-sized within the system, thus increasing the potential for job cost savings. For complete Hazen- Williams charts, refer to "Dyna-Flow Hydraulic Data Tables?' Specifications NPS Nominal I.D. WI. WI. (H20 Filled) Pcsl WI/Lilt (21') WI/Lilt (24') WI/Lift (25') In; mm In; mm Lbs/Ft; Kg/rn Lbs/Ft; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg 1' 1.191 0.830 1.31 91 1,586 1,812 1,888 25 30.3 1.2 1.95 91 719 822 856 11/4' 1.536 1.059 1.87 61 1,356 1,550 1,615 32 39.0 1.6 2.78 61 615 703 733 11/2' 1.728 1.667 2.71 61 2,135 2,440 2,542 40 43.9 2.5 4.03 61 968 1107 1153 2.203 2.104 3.79 37 1,634 1,868 1,946 50 56.0 3.1 5.64 37 741 847 883 21/2' 2.703 2.564 5.10 30 1,615 1,846 1,923 65 68.7 3.8 7.59 30 733 837 872 3.314 3.387 7.18 19 1,351 1,544 1,608 80 84.2 5.0 10.69 19 613 700 729 4' 4.310 4.473 10.86 19 1,784 2,039 2,124 90 109.5 6.7 16.16 19 809 925 963 Dyna-Flow products are coated with an environmentally approved and specially formulated modified-acrylic or water-based coating. This durable coating is paintable. The black coating acts as an excellent primer and is resistant to weathering and U.V. degradation from outdoor storage. Metallurgical properties provide excellent fabrication characteristics for end prep finishes, welding and roll grooving. There is no special process or equipment needed for fabrication and installation. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial Formula, "ABF". In scientific laboratory test, ABS proved to have superior resistance to microbial colonization of pipe walls, thereby delaying or possibly preventing the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. Dyna-Flow/Super Flo pipe is manufac- tured to meet ASTM A-795 Type E, Grade A and is in compliance with NFPA-13 and NFPA-14. All sizes of Dyna Flow/Super Flo are UL Listed, FM Approved and ULC Listed. @ <~> (R) Listed Approved Listed Dyna-Flow/Super Flo is UL/ULC Listed for use with roll grooved, plain-end couplings, and welded joints for wet, dry, preaction and deluge systems. It is FM Approved for roll grooved, plain-end, and welded joints for wet systems. Refer to appropriate documentation for up-to-date listing and approval information. Dyna- Flow/Super Flo is now available "hot- dip" galvanized and has been specifically approved by FM for dry systems uses. Lightweight and easy to install, resulting in more efficient use of your freight and labor dollars. Provides stability needed to comply with standard hanger spacing (15 ft O.C.) per NFPA. Available in Standard lengths for your convenience, or can be ordered in custom lengths upon approval. Fast cutting and welding, as well as easy roll grooving and end preparation. Available in Factory roll grooved form for quicker shop turnaround. Clean, durable mill coating provides longer "shelf life" and acts as an excellent primer for custom paint applications. tqco/Flow Control 16100 S. Lathrop • Harvey, IL 60426 Customer Service: 'Y allied 11350 Norcom Rd. • Philadelphia, PA 19154 (800) 882-5543 TUBE & CONDUIT 2525 N. 27 th Ave. • Phoenix, AZ 85009 Fax 708-339-1806 S2-3 3HI- 1 0/ac I Schedule-1O®/Schedule-40® Fully Listed and FM Approved Sprinkler Pipe When you specify Schedule-1O/Schedule-40 sprinkler pipe you get a UL listed and FM approved product. Although these products do not require separate approvals, Schedule-10/Schedule-40 gives you the extra quality assurance you demand. Our Sch-10 (1i"- 8") pipe and Sch-40 (1"- 214H) pipe have passed the same thorough lab testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. [iSpecifications NPS Nominal I.D. WI. WI. (1120 Filled) Pcs/ WI/Lift (21') WI/Lift (24') WI/Lift (25') In; mm In; mm Lbs/Ft;Kg/m Lbs/Ft;Kg/ni Lift Lbs, Kg Lbs; Kg Lbs; Kg 1.049 1.680 2.05 70 2,470 2,822 2,940 25 26.6 2.5 3.05 70 1,120 1,280 1,334 11/4' 1.380 2.270 2.93 51 2,431 2,778 2,894 32 35.1 4.36 4.36 51 1,103 1,260 1,313 11/2" 1.610 2.720 3.61 44 2,513 2,872 2,992 40 40.9 4.0 5.37 44 1,140 1,303 1,357 2.067 3.650 5.13 30 2,300 2,628 2,738 50 52.5 5.4 7.63 30 1,043 1,192 1,242 2h/2 2.469 5.790 7.86 19 2,310 2,640 2,750 65 62.7 8.6 11.73 19 1,048 1,197 1,247 I'I Specifications i NPS Nominal I.D. WI. WI. (H20 Filled) Pcs/ WI/Lilt (21') WI/Lift (24') WI/Lift (25') In; mm In; mm Lbs/Ft; Kg/rn LbslFt; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg 1' 1.097 1.400 1.81 91 2,675 3,053 3,185 25 27.9 2.1 2.70 91 1,213 1,385 1,445 11/4' 1.442 1.810 2.52 61 2,319 2,664 2,760 32 36.6 2.7 3.75 61 1,052 1,208 1,252 11/2' 1.682 2.080 3.04 61 2,664 3,045 3,172 40 42.7 3.1 4.52 61 1,208 1,381 1,439 2.157 2.640 4.22 37 2,051 2,344 2,442 50 54.8 3.9 6.28 37 930 1,063 1,108 21/2" 2.635 3.530 5.89 30 2,224 2,542 2,648 65 66.9 5.3 8.77 30 1,009 1,153 1,201 3.260 4.330 7.94 19 1,728 1,975 2,057 80 82.8 6.4 11.82 19 784 896 933 4.260 5.610 11.78 19 2,238 2,558 2,665 90 108.2 8.3 17.53 19 1,015 1,160 1,209 5.295 7.77 17.33 10 1,632 1,865 1,943 125 134.5 11.56 25.80 10 740 846 881 6.357 9.290 23.03 10 1,951 2,230 2,322 150 161.5 13.8 34.27 10 885 1,012 1,053 8" 8.249 16.490 40.15 7 2,424 2,770 2,885 200 209.5 24.5 59.75 7 1,100 1,256 1,309 Schedule-10/Schedule-40 product can be "hot-dip" galvanized to meet FM requirements for thy systems in accordance with the zinc coating specifications of ASTM A-123. rinr Cn Our advanced formula mill coating of- fers a clean, durable surface. It is also paint-ready for custom color applications without special preparation. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial For- mula, "ABF". In scientific laboratory test, ABS proved to have superior resis- tance to microbial colonization of pipe walls, thereby delaying or possibly pre- venting the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. Meets "Buy American" requirement and is available through distributors in the USA, Canada and Mexico. hSpecifications&Approvaisj Schedule-10/Schedule-40 pipe are in compliance with the following: ASTMA-135, and NFPA 13. Both pipe products have a working pressure rating of 300 psi maximum and also meet the stringent requirement for the following tests: Welded Outlets I . Hydrostatic Pressure Side Wall Rupture Vibration Test I tqc 0/Flow Control @ <~> 9 Listed Approved Listed 16100 S. Lathrop • Harvey, IL 60426 QT- Customer Service: allied 11350 Norcom Rd. . Philadelphia, PA 19154 (800) 882-5543 TUBE & CONDUIT 2525 N. 27th Ave. Phoenix, AZ 85009 Fax 708-339-1806 S5 -3 Bulletin 154 Rev.F Model G4A Quick Response Reliable Concealed Automatic Sprinkler The Concealer® UL Quick Response FM Standard Response Concealed Sprinkler With a 1/2" (13mm) or 11/2" (38mm) Adjustment Features Cover plate attachment with )4" (13mm) assembly adjustment. Smooth aesthetic ceiling profile. Factory installed protective cap. Available in brass, chrome or black plated and white painted finishes. Ordinary temperature rating. Multiple orifices for design flexibility. Approvals & Listings Underwriters Labortories, Inc. (UL)- Quick Response Underwriters Laboratories of Canada (ULC)- Quick Response Factory Mutual Research Corp. (FM)- Standard Response Light Hazard Occupanicies- No Limitations Ordinary Hazard Occupancies Groups 1 & 2 Wet Systems Only 4. NYC MEA 258-93-E - Quick Response U.S. Patent number 4,880,063. Application The Reliable Model G4A Concealer® is the most versatile quick response concealed sprin- kler available. It provides the best form of fire protection while offering an attractive appearance and ½" (13mm) of cover adjust- ment for ease of installation. The small diameter cover plate as- sembly is easily attached and blends into the ceiling, concealing the most dependable fire protec- tion available, an automatic sprinkler system. The Model G4A Concealer® is designed for use where aesthetic appearance is important. Offices, hospitals, motels and restaurants are but a few of the applications where it can be used. It is available in different orifice sizes allowing the designer to optimize system performance, thereby achieving a very efficient installation. The Model G4A Concealer® is a UL Listed Quick Response Concealed sprinkler intended for use in accordance with NFPA 13. FM Approves this sprinkler as a standard response concealed sprinkler intended for use in accordance with FM Loss Prevention Data Sheet 2-8N. Product Description The Reliable Model G4A Concealer® uses a proven quick re- sponse fusible element in a standard style sprinkler frame with a drop-down deflector. This assembly is recessed into the ceiling and concealed by a flat cover plate assembly. The threaded engagement provides ½" (13mm) of cover adjustment. The flat cover plate is attached to the skirt using either 135°F (57°C) or 165°F (74°C) ordinary temperature classification solder. When the ceiling temperature rises, the solder holding the flat cover plate melts, the flat cover plate released thus exposing the sprinkler inside to the rising ambient temperature. The subsequent fusing of the element opens the waterway and causes the deflector to distribute the water. Any secure engagement between the cover plate and cup will assure that the drop-down deflector is properly located below the ceiling. I I I k I The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Model G4 Sprinkler Wrench UL Listing Category Sprinklers, Automatic and Open Quick Response Sprinkler UL Guide Number VN IV Installation Do not install the G4A Concealer5 in ceilings which have positive pressure in the space above. Cut a 2/ inch (67mm) diameter hole is cut in the ceiling, the sprinkler is easily installed with the Model G4 Wrench. The wrench has drive tangs which insert into the cup slots. When installing a sprinkler the wrench is first positioned into the sprinkler/cup assembly until the wrench tangs engage the drive slots in the top of the cup (there are two sets of drive slots in the cup). The sprinkler is then tightened into the pipe fitting. When inserting or removing the wrench from the sprinkler/cup assembly, care should betaken to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER/CUP ASSEMBLY. Install the cover plate by hand turning the cover in the clockwise direction until it is tight against the ceiling. A protective cap is provided to protect the drop-down sprinkler deflector from damage which could occur during construction before the cover plate is installed. The cap is factory installed inside the sprinkler cup. Remove cap to install sprinkler, then re-install cap until the cover plate is installed. Maintenance The Model G4A Concea145 should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove any sprinkler that has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. Technical Data Ordering Information Sprinkler Model Nominal Orifice Flat Cover Plate Assembly Finish Inlet Type Cover Plate Finishes(" Standard Finishes Bronze Chrome White Paint Special Application Finishes Bright Brass Black Plating Black Paint Off White Satin Chrome 111 Other finishes and colors are available on special order. Consult factory for details. Temperature Rating I Classification Sprinkler Cover Plate Max. Ambient I Temp. Ordinary I 165°FR4C 135°F157°C 100FJ38°C Intermediate 212°F1100°C 165°F/74°C l50F/66°C Sprinkler Inlet Total Adjustment Nominal Orifice Nominal K Factor Thread Approvals Sprinkler ldentifcation (SIN) US I Metric Non Adiustable 1/211 (13mm) ½"(15mm) 5.6 1 80 ½" NPT (R½) 1,2,3,4 R5415 Non Adjustable 1/2"(13mm) (11 mm) 4.2 ] 60 1/2 -NPT (R½) 1,2,4 R5413 Non Adjustable 112"(13mm) "(10mm) 2.8 40 ½"NPT(R½) 1,2,3,4 R5411 Adjustable 1 1½"(38mm) 1/2"(15mm) 5.6 1 80 1" NPT Male or Female 1,2,4 R5418 Adjustable 11/2"(38mm) (11mm) 4.2 1 60 1" NPT Male or Female 1,2,4 R5413 Adjustable 11/2" (38mm) /" (10mm) 1 2.8 I 40 1" NPT Male or Female 1,2,4 85412 ' e I ftfl iflil I il~i~z ME - 2J/8fl 1A E 10 CEII~, 00 V ZOEIV jr-1 , Fig.1 - 1/2" NPT Non-Adjustable Inlet Fig. 2 - 1" NPT Male-Adjustable Inlet Fig. 3 - 1" NPT Female-Adjustable Inlet The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputable Sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by Reliable' The Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address ® Recycled Paper Revision lines indicate updated or new data. EG. Printed in USA 4/07 PIN 9999970150 The ConcealerPlus is designed for use where aes- thetic appearance is important. Offices, hospitals, and restaurants are but a few of the applications where it can be used. The Model G4 XLO QREC/EC ConcealerPlus sprinklers are for use in accordance with NFPA 13 for light hazard occupancies. The Concealers can eliminate the need for pre- cise cutting of drop nipples. The Push-on/Thread-off cover plate assembly can be adjusted without tools to fit accurately against the ceiling. The fire protection system need not be shut down when adjusting or re- moving the Push-on/Thread-off cover plate assembly. Bulletin 144 Rev.E The ConcIer 1S 11.2 K Factor 16ftx 16ft(4.9m x4.9m)& 1 8ft x 1 8ft (5.5m x 5.5m) Coverage Quick Response Sprinkler I Model G4 XLO QREC/EC Quick Response, Extended Coverage Concealed Sprinkler (SIN R4441) Features: Standard Response (EC) 20 ft x 20 ft (6.1 m x 6.1 m) coverage for light hazard occupancies. Quick Response (QREC) 16ft x 16ff (4.9m x 4.9m) and 18ft x 18ft (5.5m x 5.5m) coverage for light hazard occupancies. Push-On/Thread-Off cover plate assembly with 1/211 (13mm) adjustment. Smooth aesthetic ceiling profile. Factory installed protective cap. Available with cover plates painted white or other colors; or brass, chrome or black plated finishes. 165°F temperature rating. Threaded cover plate does not require clips or springs. US Patent No. 6,082,463 Product Description Application The ConcealerPlus uses a 165°F levered fusible alloy Model G4 XLO QREC/EC is the most versatile ex- solder link in an extra large orifice sprinkler frame tended coverage sprinkler available. The Model G4 with a drop-down deflector. This assembly is XLO QREC/EC ConcealerPlus pro- recessed into the ceiling and concealed by a flat vides the best form of fire protection for light hazard occupancies by offer- ing attractive appearance and 1/2" (13mm) of cover adjustment for ease U of installation. The small diameter Push-on/Thread-off cover plate as- sembly is easily and positively +.-.I.-.....-1 .-...-..-1 kl,,.1.-.,-i ..+.-S 4k Listings & Approvals Listed by Underwriters Laboratories, Inc and certified by UL for Canada (cULus). NYC MEA 258-93-E Note: Approvals are Light Hazard only. UL Listing Categories Sprinklers, Automatic & Open Quick Response Extended coverage Sprinkler rusri-ori, I riresu-oli cover pii assembly. I Fl Push-on/Thread-off cover plate and sprinkler cup assemblies are held tight by a flexible tooth engagement to the threaded cup. This threaded engagement provides ½" (13mm) of cover adjustment. The flat cover plate is attached to the skirt using 135°F (56°C) ordinary temperature classification solder, forming the Push-on/Thread-off iit u iu i.iel Iueu ii iu iie e iy, cover plate assembly. When the ceiling temperature concealing the most dependable fire protection avail- rises, the solder holding the cover plate to skirt melts, able, an automatic sprinkler system. The Reliable Automatic Sprinkler Co., Inc., 525 North MacQuesten Parkway, Mount Vernon, New York 10552 I COVERAGE AREA Flow Pressure psi (bar) I Coverage Rate gpm (Lpm) ft. x ft. (mxm) I Nominal K = 11.2(160) 30 (113.5) 7.2(0,49) 16x 16 (4,9x4,9) I 33(125.0) 8.7(0,60) 18 x (5,5 x 5,5) I 40(151,0) 12.8(0,88) 20 x 2012) (6,1 x 61) (')Quick Response (QREC) Listed. (2) Standard Response (EC) Listed. Sprinkler Identification Number (SIN): R4441 Ordering Information Installation Wrench Specify Model G4 XLO EC Sprinkler Model Cover Plate Finish Cover Plate Finishes(1) Bright Brass Plated Chrome Plated Black Plated White Paint (1) Other finishes and colors are available. Consult factory for details. Note: Paint or any other coatings applied over the factory finish will void all approvals and warranties. Installation Sprinklers and push-on/thread-off cover plate assemblies are packaged separately. A plastic cap is provided for protecting the sprinkler during construction. Minimum sprinkler spacing is 10'-6". 14.410018 ,-. Ia .5/4 REDUCING TEE OR ELBOW I , I fl' 1mhh t I 7mmJ DOL 25 23 OZ [5m (66.7mmJ SPRINKLER CUP f4lx. FACE OF ASSEMBLY PITTING TO CSILING DIMENSION GSIUNG COVER PLArE I ASSEMBLY T =~1771 37K r'-- -. 3 5/76 0L4. • 3/I6 I/f [I3mm] MAx. [84mm] (4.8mm] COVER ADJUSTMENT I the cover plate released thus exposing the sprinkler I inside to the rising ambient temperature. The subsequent fusing of the element opens the water-way and causes the deflector to drop into position for distributing the water. Any secure I engagement between the cover plate and cup will assure that the drop-down deflector is properly located below the ceiling. I Installation Do not install the ConcealerPlus in ceilings which have positive pressure in the space above. After in- stallation, inspect all sprinklers to ensure that both the gap between the cover plate and ceiling and the 4 slots in the cup are open and free from any air flow impediment. After a 2/" diameter hole is cut in the ceiling, the sprin- kler is to be installed with the Model G4 XLO EC Wrench. When installing a sprinkler, the wrench is first positioned into the sprinkler/cup assembly until two wrench tangs fully engage drive slots in the top of the cup. The sprin- kler is then tightened into the pipe fitting. When inserting or removing the wrench from the sprinkler/cup assembly care should be taken to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER/CUP ASSEMBLY. A protective cap is provided to protect the drop down deflector from damage which could occur dur- ing construction before the cover plate is installed. The cap is factory installed inside the sprinkler cup. Remove cap to install sprinkler, then replace cap un- til cover plate is installed. After the ceiling has been installed with sprinklers, install the cover plates into cups. Final adjustment of each cover is made by hand-turning the cover in the clockwise direction until it is tight against the ceiling. THE MODEL G4 XLO QREC/EC CONCEALER MUST BE INSTALLED ONLY WITH A 135°F RATED COVER WHICH HAS BEEN LISTED WITH THE SPRINKLER. Standard Temperatures Classification Sprinkler Cover Plate I Max. Ceiling Temperature Ordinary 165°F174°c 135°F157°c j 100F/38°c The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the united States, Canada and foreign countries. Manufactured by Refia I ble"' The Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 668-3470 Corporate Offices www.reliablesprinkler.com Internet Address ®Recycled Paper Revision lines indicate updated or new data. EG. Printed in U.S.A 9/03 PIN 9999970123 LIU - FME SPR11VILER COflPORAflON QUICK RESPONSE A UTOMA TIC SPRINKLERS GL SERIES UPRIGHTPENDENT VERTICAL SIDEWALL HORIZONTAL SIDE WALL DESCRIPTION AND OPERATION CONVENTIONAL (OLD STYLE) The Globe Quick Response GL Series Sprinklers are a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. While the Quick Response Sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard spray sprinklers are specified when 1W / allowed by the applicable standards. It offers the additional feature of greatly increased safety to life and is available in various styles, orifices, temperature ratings and finishes to meet many varying design require- r i ments Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction. The heart of Globe's GL Series sprinkler proven actuating QUICK RESPONSE assembly is a hermetically sealed frangible glass ampule that contains UPRIGHT CONVENTIONAL a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds •••s the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern depending L upon the deflector style used. The sprinkler and escutcheon are not factory assembled. As- sembly is done in the field. TECHNICAL DATA QUICK RESPONSE See reverse side forApprovals and Specifications. PENDENT VERTICAL SIDEWALL Temperature Ratings- 135'F (57°C), 155°F (68°C), 175°F (79°C), 200-F(93-C),286-F(141-C). WaterWorking Pressure Rating -175 psi (12 Bars). Factory tested hydrostatically to 500 psi (34 Bars). ° Maximum low temperature glass bulb rating is-67°F(-55°C). ° Frame - bronze. Deflector - brass • Screw - brass Bulb seat - copper • Spring - nickel alloy • Seal - teflon Bulb - glasswith alcohol based solution,3mm size. QUICK RESPONSE HORIZONTAL SIDEWALL SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING CLASSIFICATION AVAILABLE SPRINKLER BULB N.F.P.A. MAXIMUM TEMPERATURES COLOR CEILING TEMPERATURE ORDINARY i71 -5FIi55F: 57°CI6ä I ORANGE/RED - INTERMEDIATE 175 F1200 F 1 79 CI93C YELLOW/GREEN r1 5Q HIGH 286 F 141 C BLUE 225 F 107C 4O77AIRPARKDRIVE, STANDISH, MICHIGAN 48658 989-846-4583 • FA)(989-846-9231 DECEMBER 2006 A-20 BULLETIN GI-5615, REV. #6 II 1 I I I I QUICK RESPONSE I A UTOMA TIC SPRiNKLERS GL SERIES I UPRIGHT a PENDENT o VERTICAL SIDE WALL HORIZONTAL SIDEWALL s CONVENTIONAL (OLD STYLE) .ç PICIF1C4 TIU rvc NOMINAL K FACTOR THREAD SIZE LENGTH ' FINISHES 2.8 (39 metric) 1/2" NPT 2 1/4" (5.7 cm) Factory Bronze 4.2 (59 metric) 1/2" NPT 2 1/4" (5.7 cm) Satin Chrome 2 Bright Chrome 5.6 (80 metric) 1/2" NPT 2 1/4" (5.7 cm) White Polyester 7.8 (111 metric) 1/2" NPT 2 1/4" (5.7 cm) Black Polyester 8.1 (116 metric) 3/4" NPT 2 7/16" (6.2 cm) Lead Coated 2 NOTE: METRIC CONVERSIONS ARE API-R0XIMA It. 'HORIZONTAL SIDEWALL 152 9/lb. 2 FINISHES AVAILABLE ON SPECIAL ORDER. 3AVAILABLE AS cULus LISTED CORROSION 4 PPPnV4r.c RESISTANT WHEN SPECIFIED ON ORDER. SIN cULus F.M. LPC NYC - DOB M0ELFAcKToR5: ME UPRIGHT GL5615 5.6 x STYLE TT1rT PENDENT VERTICAL 0L5632 5.6 X X X X X X X - - - SIDEWALL GL8133 8.1 X X X X X X - - - - dL2826 2.8 X X X X X X - - - X HORIZONTAL GL4226 4.2 X X X X X X - - - X SIDEWALL GL5626 5.6 X X X X X X X - - X GL8127 8.1 X X X X X X - - - - CONVENTIONAL GL5624 5.6 X X X X X - - X X - (OLD STYLE) GL8125 8.1 X X X X X - - X x - HORIZONTAL SIDEWALL cULus LISTED FOR DEFLECTOR 4 10 12 ELUW I lIE CEILINI.i, I-M AVVKUVtU ' I U 0 T VERTICAL SIDEWALL SPRINKLER cULus LISTED FOR LIGHT HAZARD ONLY. PENDENT VERTICAL SIDEWALL cULus LISTED FOR 6' MIN. SPACING. UPRIGHT VERTICAL SIDEWALL cULus LISTED FOR 9 MIN. SPACING. ORDERING INFORMA TIOIV "112" NPT. SPECIFY GLOBEPRODUCT WARRANTY "Quantity • Model Number Style I " Orifice Thread Sizes Temperature Finishes desired Quantity - Wrenches - P/N 325390 (1/2"); P/N 312366 (L.O.) on-2 LOBE FIRE SPRINKLER U CORPORATION DECEMBER 2006 I Globe agrees to repair or replace any of its own manufactured products found to be defective in mate- rial or workmanship for a period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 FAX 989-846-9231 1-800-248-0278 www.globesprinkler.com PRINTED U.S.A. BULLETIN GL5615, REV. #6 QUICK RESPONSE RECESSED PENDENT QUICK RESPONSE RECESSED HORIZONTAL SIDEWALL VALN an 0 11h LOB 10. 41 E yo. FIRE SPRINKLER CORPORATION QUICK RESPONSE A UTOMA TIC SPRINKLERS GL SERIES RECESSED PENDENT RECESSED HORIZONTAL SIDEWALL DESCRIPTION AND OPERATION The Globe Quick Response GL Series Sprinkler is a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. While the Quick Response Sprinkler provides an aesthetically pleasing ap- pearance, it can be installed wherever standard spray sprinklers are specified but offers the additional feature of greatly increased safety to life. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction. The heart of Globe's GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern depending upon the deflector style used. The sprinkler and escutcheon are not factory assembled. Assembly is done in the field. TECHNICAL DATA See reverse side for Approvals and Specifications. *Temperature Ratings - 135°F (57°C), 155°F (68°C), 175°F (79°C), 200°F (93°C), 286°F (141°C). 0 Water Working Pressure Rating - 175 psi (12 Bars). Factory tested hydrostatically to 500 psi (34 Bars). Maximum low temperature glass bulb rating is -67°F (-55°C). Frame - bronze • Deflector - brass a Screw - brass Bulb seat - copper a Spring - nickel alloy a Seal - teflon Bulb - glass with alcohol based solution, 3mm size. *Escutcheon Assembly - steel cPRThJKIJR TF)VIPFRA TURF RATING/CLASSIFICATION and COLOR CODING AVAILABLE SPRINKLER BULB N.F.P.A. MAXIMUM CLASSIFICATION 0 TEMPERATURES COLOR CEILING TEMPERATURE ORDINARY 135'F/155'F `57'C/68'C I ORANGE/RED 100 F 38 C INTERMEDIATE 175'F/200'F 79'C/93'C YELLOW/GREEN 150-F 66-C HIGH 286'F 141'C' BLUE 225 *F 107 C 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 FAX989-846-9231 DECEMBER 2006 A-24 BULLETIN GL2801, REV. #5 QUICK RESPONSE A UTOMA TIC SPRINKLERS GL SERIES RECESSED PENDENT RECESSED HORIZONTAL SIDEWALL SPECIFICATIONS NOMINAL "K" FACTOR THREAD SIZE LENGTH ' FINISHES 2.8 (39 metric) 1/2 NPT 2 1/4' (5.7 cm) Factory Bronze 4.2 (59 metric) 1/2" NPT 2 1/4" (5.7 cm) Satin Chrome 2 Bright Chrome 5.6 (80 metric) 112" NPT 2 1/4" (5.7 cm) White Polyester 7.8 (111 metric) 1/2" NPT 2 1/4" (5.7 cm) Black Polyester 8.1 (116 metric) 3/4" NPT 1 2 7/16" (6.2 cm) Lead Coated 2 NOTE: METRIC CONVERSIONSAREAPPROXIMATE. 'HORIZONTAL SIDEWALL IS 2 9/16". FIN ISHESAVAILABLE ON SPECIAL ORDER. 3C-UL LISTED CORROSION RESISTANT - POLYESTERMUSTBESPECIFIEDON ORDER. APPROVALS STYLE SIN MODEL K FACTOR 135°F 57°C 155°F 68°C 175°F 79°C 200°F 93°C **2860F 141°C t cULus t FM LPC CE NYC - DOB MEAI0I-92-E GL2801 2.8 X X X X X X - - - X GL4201 4.2 X X X X X X - - - x PENDENT GL5601 5.6 X X X X X X X X X X RECESSED GL8101 7.8" X X X X X X X - - x 0L8106 8.1 X X X X X X X X X X GL2826 2.8 X X X X X X - - - x HORIZONTAL GL4226 4.2 X X X X X X - - - x SIDEWALL RECESSED § GL5626 5.6 X X X X X X - - - x 0L8127 8.1 X X X X X X - - - - I CROSS SECTIONS IN. LN FEND El 1 LOBE tI. FIRE SPRINKLER CORPORATION DECEMBER 2006 §I1Ol<ILON I ALIUWALLcULuS LIZJ I L) I-Ul< L)J-L., I UI(4 I U 1ZbWVV INtUtILINU. t5.6KORIFICE,7.8KORIFCEANDB.1KORIFICELISTED FORALL HAZARDS. "7.8KX112°NPT. ""286°FcULus LISTED ONLY. t1112"RECESSEDESCUTcHEONSARE REQUIRED FOR FMP,PPROVEDSPRINKLERS. ORDERING INFORMATION SPECIFY Quantity • Model Number • Style Orifice • Thread Sizes " Temperature Finishes desired Quantity - Recessed Wrenches - P/N 325391 (1/2"); P/N 325401, Rev. F (L.O.) Quantity - Protective Caps - P/N 327109-CAP (Friction Fit Recessed) GLOBE®PRODUCT WARRANTY Globe agrees to repair or replace any of its own manufactured products found to be defective in material or workmanship for a period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). 4O77AIRPARKDRIVE. STANDISH. MICHIGAN 48658 989-846-4583 FAX 989-846-9231 1-800-248-0278 www.globesprinkIer.com PRINTEDU.S.A. BULLETIN GI-2801, REV. #5