Loading...
HomeMy WebLinkAbout2730 GATEWAY RD; ; AS120105; Permit9/14/22, 2:14 PM AS 120105 Permit Data City of Carlsbad Sprinkler Permit Job Address: 2730 GATEWAY RD Permit Type: SPRINK Parcel No: 2132632600 Lot #: 0 Permit No: AS120105 Status: APPROVED Applied 9/6/2012 Approved: 9/21/2012 Reference No.: Issued: 9/21/2012 PC #: Inspector: Project Title: PIZZA PORT NEW COMMERCIAL SPRINKLER SYSTEM Applicant: EPIC FIRE PROTECTION, INC. 765 TURTLE POINT WY SAN MARCOS, CA 760-310-6122 Owner: MARSAGLIA PROPERTIES L C P0 BOX 1697 CARLSBAD CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 1,587 0 1,587 J 0 about:blank 1/1 ot Flow Test Record ( . ... . Test Hydrant. . . . . Location _(S ZT*( CEE t2' Hydrant ID No..Size Main_____________ Static .............. . Residual ............12. Pressure Drop..(1)DI 1)......K factor for PD! 1 Flow. Hydrant(s) Hydrant 1 location__Z.13c 4r'.i1 pcz Hydrant 2 location____________________________________________________ Hydrant 3 location____. . . . Hydrant 1 Pitot PSI GPM Size of Orifice '2 Hydrant 2 Pitot PSI GPM: Size of Orifice__________ Hydrant 3 Pitot ___PSI GPM:. Size of Orifice._________ Total: _t4c'O . . (Qi) Calculated test and flow data - 0 x P02 k =Q2 . PDI*k. . . . Desired Residual 20 Pressure Drop (PD 2)... tOb K factor PD 2:___L2 x ITi9b divided by __2. 2c equals ci t'b GPM at 20 psi residual Qi PD2k PD1k Q2 Comments Test conducted fOr: . . Conducted by__I't,C- k0c Date: _ - . 2... Time: CO IkW /St2-oIos cvu EPIC FIRE PROTECTION, INC. = 765 TURTLE POINT WAY U-u SAN MARCOS, CA 92069 (760) 310-6122 FAX (760) 798-0556 Hydraulic Design Information Sheet Name: PIZZA PORT - ROOF SYSTEM Date: 8-4-12 Location: 2730 GATEWAY RD. CARLSBAD Building: NEW System No. 1 OF 1 Contractor: EPIC FIRE PROTECTION, INC. Contract No. Calculated By: RAB Drawing No. 2 OF 2 Construction: 0 Combustible [1 Non-Combustible Ceiling Height 27 Ft. SYSTEM DESIGN NFPA 13: Light Hazard Ordinary Hazard Group I LI] NFPA 231 [1] NFPA 231C: Figure: fl Other (Specify) El Specific Ruling Made By I D 2 LI 3 tK Extra Hazard Curve: Date Area of Sprinkler Operation 2000 System Type Density .495 M Wet LI Dry [1 Deluge L] Pre-Action Area Per Sprinkler 100 SQ FT MAX Sprinkler or Nozzle Hose Allowance GPM: Inside 100 Make TYCO Model K-17 Hose Allowance GPM: Outside 400 Size ~" K-Factor: 16.8 Rack Sprinkler Allowance Temperature Rating 286 CALCULAlIUN SUMMARY GPM Required 1351.35 PSI Required 83.87 At Base of Riser "C" Factor Used: Overhead 120 Underground 150 WATER SUPPLY Water Flow Test Pump Data Tank or Reservoir Date & Time 6-19-12 Rated Capacity Capacity Static PSI 128 At PSI Elevation Residual PSI 121 Elevation GPM Flowing 1300 Well Elevation 0 Proof Flow GPM Location SITE Source of Information EPIC FIRE AND CARLSBAD WATER DIST COMMODITY S'IORAUE Commodity BEER STORAGE Storage Height 20' Storage Method: Solid Piled 0 Rack Single Row Z Conventional Pallet fl Double Row El Slave Pallet Eli Multiple Row U Open Flue Spacing In Inches Longitudinal 6" Transverse 3" Horizontal Barriers Provided NA Class 1-111 Location WHSE Area 20,000 SQ FT Aisle Width 8 % Palletized 0 % Rack 100 LII Automatic Storage El Encapsulated LI Solid Shelving 0 Non-Encapsulated Clearance From Top of Storage to Ceiling 3 Ft.. 0 In. 250 240 230 220 210 200 190 180 170 160 150 140 130 120 110 100 90 80 70 60 50 40 30 20 IC r PIZZA PORT ROOF CALC .495/2000 (PEAKED) Sigma Dynamics Corporation 7700 Supply/ Demand Graph -i Margin Pressure 5.79 PSI Flow 451.40 GPM N 1.85 200 400 600 800 1000 1200 1400 1600 1800 20 Water Flow (GPM) System Demand.. Sprinkler Demand 94.93 PSI @ 1251.35 GPM Additional Flows 500.00 GPM Hose at Source 0.00 GPM Total Demand 98.47 PSI @ 1751.35 GPM Water Supply.. Static 115.20 PSI Residual 108.90 PSI @ 1300.00 GPM Elevation 0.00 PSI 00 SUBMITTAL SERIAL NO:2932HY7 08-09-2012 PAGE 1 PIZZA PORT ROOF CALC .495/2000 (PEAKED) FLOW TEST RESULTS Water Supply STATIC 115.20 PSI RESIDUAL 108.90 PSI @ 1300.00 GPM CITY PRESSURE AVAILABLE AT 1751.3 GPM 104.27 PSI SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW K-FACTOR PRESSURE 100 7429 47.52 16.80 19.55 101 73.69 47.52 16.80 19.24 102 73.69 47.52 16.80 19.24 107 52.15 47.52 16.80 9.64 108 49.57 47.52 16.80 8.71 109 48.44 47.52 16.80 8.31 110 48.21 47.52 16.80 8.24 111 48.25 47.52 16.80 8.25 112 48.91 47.52 16.80 8.47 113 50.78 47.52 16.80 9.14 114 51.53 47.52 16.80 9.41 115 48.96 47.52 16.80 8.49 116 47.84 47.52 16.80 8.11 117 47.61 47.52 16.80 8.03 118 47.65 47.52 16.80 8.04 119 48.29 47.52 16.80 8.26 120 50.14 47.52 16.80 8.91 121 51.40 47.52 16.80 9.36 122 48.85 47.52 16.80 8.46 123 47.74 47.52 16.80 8.08 124 47.52 47.52 16.80 8.00 125 47.56 47.52 16.80 8.01 126 48.21 47.52 16.80 8.24 127 50.07 47.52 16.80 8.88 08-09-2012 PAGE 2 SUBMITTAL SERIAL NO:2932HY7 PIZZA PORT ROOF CALC .495/2000 (PEAKED) TOTAL WATER REQUIRED FOR SYSTEM 1251.35 GPM OUTFLOWS AT 1 400.00 GPM OUTFLOWS AT 3 100.00 GPM TOTAL WATER REQUIREMENT 1751.35 GPM PRESSURE REQUIRED AT 0 98.47 PSI MAXIMUM PRESSURE UNBALANCE IN LOOPS 0.00 PSI MAXIMUM VELOCITY FROM 2 TO 3 29.72 FPS SUBMITTAL SERIAL NO:2932HY7 08-09-2012 PAGE 3 PIZZA PORT ROOF CALC .495/2 000 (PEAKED) Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 118 117 2.203 L 8.0,0 C=120 PT 8.03 (117) Q 12.93 F=0 F 0.00 PE 0.00 EL T 8.00 0.0016 PF 0.01 119 118DQ 47.65 2.203 L 8.00 C=120 PT 8.04 (118) Q 60.58 F=0 F 0.00 PE 0.00 BL T 8.00 0.0273 PF 0.22 120 119DQ 48.29 2.203 L 8.00 C=120 PT 8.26 Q 108.86 F=0 F 0.00 PE 0.00 EL T 8.00 0.0806 PF 0.64 77 120DQ 50.14 2.203 L 57.93 C=120 PT 8.90 Q 159.00 F=0 F 0.00 PE 0.00 BL T 57.93 0.1625 PF 9.41 37 77 2.203 L 0.83 C=120 PT 18.31 ( 77) Q 159.00 F=T. F 11.60 PE 0.36 RN T 12.43 0.1625 PF 2.02 38 37DQ -137.48 2.703 L 10.00 C=120 PT 20.69 ( 37) Q 21.52 F=O F 0.00 PE 0.00 CM? T 10.00 0.0015 PF 0.02 39 38DQ 159.28 2.703 L 10.67 C=120 PT 20.71 ( 38) Q 180.80 F=0 F 0.00 PE 0.00 CM2 T 10.67 0.0761 PF 0.81 40 39DQ -52.29 2.703 L 12.00 C=120 PT 21.52 ( 39) Q 128.51 F=0 F 0.00 PE 0.00 CM2 T 12.00. 0.0405 PF 0.49 41 40]DQ -39.98 2.703 L 12.00 C=120 PT 22.01 ( 40) Q 88.53 F=0 F 0.00 PE 0.00 CM2 T 12.00 0.0203 PF 0.24 42 41DQ -32.39 2.703 L 12.00 C=120 PT 22.25 C 41) Q 56.14 F=0 F 0.00 PE 0.00 CM2 T 12.00 0.0087 PF 0.10 43 42DQ -28.61 2.703 L 12.00 C=120 PT 22.35 ( 42) Q 27.52 F=0 F 0.00 PE 0.00 CM2 T 12.00 0.0023 PF 0.03 83 43 2.203 L 0.83 C=120 PT 38 ( 43) Q 27.52 F=T F 11.60 PE -o.-- RN T 12.43 0.0063 PF 0,08 SUBMITTAL SERIAL NO:2932HY7 08-09-2012 PAGE 4 PIZZA PORT ROOF CALC .495/2000 (PEAKED) Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 63 83 2.203 L 94.67 C=120 PT 22.10 ( 83) Q 27.52 F=0 F 0.00 PE 0.00 EL T 94.67 0.0063. PF 0.60 23 63 2.203 L 0.83 C=120 PT 22.70 ( 63) Q 27.52 F=T F 11.60 PE 0.36 RN T 12.43 0.0063 PF 0.08 22 23 2.703 L 12.00 C=120 PT 23.14 ( 23) Q 27.52 F=0 F 0.00 PE 0.00 CM1 T 12.00 0.0023 PF 0.03 21 22DQ 28.61 2.703 L 12.00 C=120 PT 2.17 ( 22) 0 56.14 F=0 F 0.00 PE 0.00 CM1 T 12.00 0.0087 PF 0.10 20 21DQ 32.39 2.703 L 12.00 C=120 PT 23.27 ( 21) Q 88.53 F=0 F 0.00 PE 0.00 CM1 T 12.00 0.0203 PF 0.24 19 20DQ 39.98 2.703 L 12.00 C=120 PT 23.51 ( 20) Q 128.51 F=0 F 0.00 PE 0.00 CM1 T 12.00 0.0405 PF 0.49 18 19DQ 52.29 2.703 L 130.17 C=120 PT 24.00 ( 19) Q 180.80 F=2E F 13.20 PE 0.00 CM1 T 143.37 0.0761 PF 10.91 17 18DQ 182.09 4.310 L 10.00 C=120 PT 34.91 ( 18) Q 362.88 F=0 F 0.00 Pt 0.00 CM1 T 10.00 0.0285 PF 0.29 16 17DQ 183.01 4.310 L 12.00 C=120 PT 35.20 ( 17) Q 545.89 F=.0 F 0.00 PE 0.00 CM1 T 12.00 0.0606 PF 0.73 15 16DQ. 184.94 4.310 L 12.00 C=120 PT 35.93 ( 16) Q 730.83 F=0 F 0.00 PE 0.00 CM1 T 12.00 0.1039 PF 1.25 14 15DQ 148.42 4.310 L 12.00 C=120 PT 37.18 ( 15) Q 879.25 F=0 F 0.00 PE 0.00 CM1 T 12.00 0.1463 PF 1.76 13 14DQ 83.89 4.310 L 12.00 C=120 PT 38.94 ( 14) Q 963.14 F=0 F 0.00 PE 0.00 CM1 T 12.00 0.1732 PF 2.08 SUBMITTAL SERIAL NO:2932HY7 PIZZA PORT ROOF CALC .495/2000 (PEAKE Location Flow Pipe Fittings in Size & From To GPM IN Devices 12 13DQ 83.56 4.310 Q 1046.70 F=0 CM1 5 12DQ 88.32 4.310 Q 1135.02 F=0 CM1 125 ------------------ 124 2.203 Q 13.43 F=O EL 126 125DQ 47.56 2.203 Q 60.99 F=0 BL 127 126DQ 48.21 2.203 Q 109.20 F=0 BL 78 127DQ 50.07 2.203 Q 159.28 F=0 BL 38 78 2.203 Q 159.28 F=T RN 123 ------------------ 124 2.203 Q 34.09 F=0 BL 122 123DQ 47.7.4 2.203 Q 81.83 F=0 BL 121 122DQ 48.85 2.203 Q 13.0.69 F=0 BL 58 121DQ 51.40 2.203 Q 182.09 F=0 BL 18 58 2.203 Q 182.09 F=T RN 08-09-2012 PAGE 5 Equiv Friction Pressure Length Loss Summary Ft PSI/Ft PSI L 12.00 C=120 PT 41.02 ( 13) F 0.00 PE . 0.00 T 12.00 0.2020 PF 2.42 L 6.00 C=120 PT 43.44 ( 12) F 0.00 PE 0.00 T. 6.00 0.2347 PF 1.41 PT 44.85 ( 5) L 8.00 C=120 PT 8.00 (124) F 0.00 PE 0.00 T 8.00 . 0.0017 PF 0.01 L 8.00 .C=120 PT 8.01 (125) F 0.00 PE 0.00 T 8.00 0.0276 PF 0.22 L 8.00 C=120 PT 8.23 (126) F 0.00 PE 0.00 T 8.09 0.0?11 PF 0.65 L 57.93 C=120 PT 8.88 (127) F 0.00 PE 000 T . 5793 0.1630 PF . 9.44 L 0.83 C=120 PT 18.32 ( 78) F 11.60 PE 0.36 T 12.43 .0.1630 PF 2.03 PT 20.71 ( 38) L 8.00 C=120 PT 8.00 (124) F 0.00 PE 0.00 T 8.00 0.0094 PF 0.08 L 8.00 C=120 PT 8.08 (123) F 0.00 PE 0.00 T 8.00 0.0475 PF 0.38 L 8.00 C=120 PT 8.46 (122) F 0.00 PE 0.00 T 8.00 0.1130 PF 0.90 L 108.24 C=120. PT 9.36 (121) F 0.00 PE 0.00 T 108.24 0.2088 PF 22.60 L 0.83 C=120 PT 31.96 ( 58) F 11.60 PE. 0.36 T 12.43 0.2088 PF 2.60 PT 34.92 ( 18) SUBMITTAL SERIAL NO:2932HY7 08-09-2012 PAGE 6 PIZZA PORT ROOF CALC .495/2000 (PEAKED) Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 116 ------------------ 117 2.203 L 8.00 C=120 PT 8.03 (117) Q 34.68 F=0 F 0.00 PE 0.00 BL T 8.00 0.0097 PF 0.08 115 116DQI 47.84 2.203 L 8.00 C=120 PT 8.11 (116) 0 82.51 F=0 F 0.00 PE 0.00 EL T 8.00 0.0483 PF 0.39 114 115DQ 48.96 2.203 L 8.00 C=120 PT 8.50 (115) Q 131.48 F=0 F 0.00 PE 0.00 T 8.00 0.1143 PF, 0.91 57 114DQ 51.53 2.203 L 108.24 C=120 PT 9.41 (114) Q 183.01. F=0 F 0.00 PE 0.00 EL T 108.24 0.2107 PF 22.81 17 57 2.203 L 0.83 C=120 PT 32.22 ( 57) Q 183.01 F=T F 11.60 PE 0.36 RN T 12.43 0.2107 PF 2.62 PT 35.20 ( 17) 111 ------------------ 110 2.203 L 8.00 C=120 PT 8.24 (110) Q 13.43 F=0 F 0.00 PE 0.00 BL T 8.00 0.0017 PF 0.01 112 111DQ 48.25 2.203 L 8.00 C=120 PT 8.25 (111) Q 61.68 F=0 F 0.00 PE 0.00 BL T 8.00 0.0282 PF 0.23 113 112DQ 48.91 2.203 L 8.00 C=120 PT 8.48 Q 110.59 F=0 F 0.00 PE 0.00 EL T 8.00 0.0830 PF 0.66 76 113DQ 50.78 2.203 L 57.93 C=120 PT 9.14 Q 161.37 F=0 F 0.00 PE 0.00 BL T 57.93 0.1670 PF 9.67 36 76 2.203 L 0.83 C=120 PT 18.81 ( 76) Q 161.37 F=T F 11.60 PE 0.36 RN T 12.43 0.1670 PF 2.08 PT 21.25 ( 36) 109 ------------------ 110 2.203 L 8.00 C=120 PT 8.24 (110) Q 34.78 F=0 F 0.00 PE 0.00 BL T 8.00 0.0098 PF 0.08 SUBMITTAL SERIAL NO:2932HY7 PIZZA PORT ROOF CALC .495/2000 (PEAKE Location Flow Pipe Fittings in Size & From To GPM IN Devices 108 109DQ 48.44 2.203 Q 83.22 F=0 BL 107 108DQ 49.57 2.203 Q 132.79 F=0 BL 56 107DQ 52.15 2.203 Q 184.94 F=0 BL 16 56 2.203 Q 184.94 F=T RN 103102 - 2.203 Q 73.24 F=0 EL 104 103 2.203 Q 73.24 F=0 EL 105 104 2.203 0 73.24 F=0 BL 106 105 2.203 0 73.24 F=0 BL 75 106 2.203 Q 73.24 F=0 EL 35 75. 2.203 Q 73.24 F=T RN 101 ------------------ 102. 2.203 Q 0.44 F=0 EL 100 1011DQ 73.69 2.203 Q 74.13 F=0 EL 08-09-2012 PAGE 7. Equiv Friction Pressure Length Loss Summary Ft PSI/Ft PSI L 8.00 C=120 PT 8.32 (109) F 0.00 PE 0.00 T 8.00 0.0490 PF ' 0.39 L . 8.00 C=120 PT 8.71 (108) F 0.00 PE 0.00 T 8.00 0.1164 PF '0.93 L 108.24 C=120 PT 9.64 F 0.00 PE 0.00 T 108.24 0.2149 PF 23.26 L 0.83 C=120 PT 32.90 ( 56) F 11.60. PE 0.36 T 12.43 0.2149 PF 2.67 PT 35.93 ( 16) L 8.00 C=120 PT 19.24 F 0.00 PE 0.00 T 8.00 0.0387 PF . 0.31 L 8.00 C=120 PT .19.55 F 0.00 PE 0.00 T 8.00 0.0387 PF 0.31 L .8.00 C=120 PT 19.86 F 0.00 PE 0.00 T .' 8.00 0.0387 PF 0.31 L 8.00 C=120 PT 20.17 F 0.00 PE 0.00 T 8.00 0.0387 PF 0.31 L 57.93 .C120 PT 20.48 F 0.00 ' PE 0.00 T 57.93 0.0387 PF 2.24 L 0.83 C=120 PT 22.72 ( 75) F 11.60 PE 0.36 T 12.43 0.0387 PF 0.48 PT' 23.56 ( 35) L 8.00 C=120 PT 19.24 (102) F 0.00 PE 0.00 T 8.00 0.0000 PF 0.00 L 8.00 ' C120 PT 19.24 (101) F 0.00 PE 0.00 T 8.00 0.0396 PF '0.32 SUBMITTAL SERIAL NO:2932HY7 PIZZA PORT ROOF CALC .495/2000 (PEAKE Location Flow. Pipe Fittings in Size & From To GPM IN Devices 55 100DQ 74.29 2.203 Q 148.42 F=0 BL 15 55 2.203 .Q 148.42 F=T RN 36 37 2.703, Q 137.48 F=0 CM2 35 36DQ 161.37 2.703 Q 298.85 F=0 CM2 34 35DQ 73.24 2.703 Q 372.10 F=0 CM2 33 34DQ -83.88 2.703 Q 288.21 F=0 CM2 32 33DQ -83.56 2.703 Q 204.65 F=0 • CM2 31 32DQ -88.32 2.703 Q 116.32 F=0 CM2 71 31 2.203 Q 116.32 F=T RN 30 71 2.203 Q 116.32 F=0 • BL 50 30DQ -61.49 2.203 Q 54.83 F=E,T • EL 10 50 2.203 Q 54.83 • F=T RN 08-09-2012 PAGE 8 Equiv Friction Pressure Length Loss Summary Ft PSI/Ft PSI L 108.24 C=120 PT 19.56 (100) F 0.00 PE 0.00 T 108.24 0.1430 PF 15.48 L 0.83 C=120 PT 35.04 ( 55) F 11.60 PE 0.36 T 12.43 0.1430 PF 1.78 PT 37.18 ( 15) L 12.00 C=120 PT 20.70 ( 37) F 0.00 PE 0.00 T 12.00 0.0458 PF 0.55 L 12.00 C=120 PT 21.25 ( 36) F 0.00 PE 0.00 T 12.00 0.1928 PF 2.31 L 12.00 C=120 PT 23.56 ( 35) F 0.00 PE 0.00 T 12.00 0.2892 PF 3.47 L 12.00 C=120 PT 27.03 ( 34) F 0.00 PE 0.00 T 12.00 0.1803 PF 2.16 L 12.00 C=120 PT 29.19 ( 33) F 0.00 PE 0.00 T 12.00 0.0957 PF 1.15 L 12.00 C=120 PT 30.34 ( 32) F 0.00 PE 0.00 T 12.00 0.0337 PF 0.40 L 0.83 C=120 PT 30.74 ( 31) F 11.60 • PE -0.36 T 12.43 0.0911 PF 1.13 L 104.42 C=120 PT 31.51 C 71) F 0.00 PE 0.00 T 104.42 0.0911 PF 9.51 L 121.75 C=120 PT 41.02 ( 30) F 16.40 • PE 0.00 T 138.15 0.0227 PF 3.14 L 0.83 C=120 PT 44.16 ( 50) F 11.60 PE 0.36 T • 12.43 0.0227 PF 0.28 SUBMITTAL SERIAL NO:2932HY7 08-09-2012 PAGE 9 PIZZA PORT ROOF CALC .495/2000 (PEAKED) Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft . PSI/Ft . PSI 11 10 4.310 L 12.00 C=120 PT 44.80 ( Q 54.83 F=0 F 0.00 PE 0.00 CM1 T 12.00 0.0009 PF 0.01 PT 44.81 C 82 -------------- 42 2.203 L 0.83 C=120 PT 22.36 ( 42) Q 28.61 F=T F 11.60 PE -0.36 RN T 12.43 0.0068. PF 0.08 62 82 2.203 L 94.67 C120 PT 22.08 C 82) Q 28.61 F=0 F 0.00 PE 0.00 EL T 94.67 0.0068 PF 0.64 22 62 2.203 L 0.83 C=120 PT 22.72 ( 62) Q 28.61 F=T F 11.60 PE 0.36 RN T 12.43 0.0068 PF 0.08 PT 23.16 ( 22) 81 41 - - -- 2.203 L 0.83 C=120 PT 22.25 ( 41) Q 32.39 F=T F 11.60 PE -0.36 RN T 12.43 0.0086 PF 0.11. 61 81 2.203 L 94.67 C=120 PT 22.00 ( 81) Q 32.39 F=0 F 0.00 PE 0.00 BL T 94.67 0.0086 PF 0.81 21 61 2.203 L 0.83 C=120 PT 22.81 ( 61) Q 32.39 F=T F 11.60. PE 0.36 RN T 12.43 0.0.086 PF 0.11 PT 23.28 ( 21) 80 40 ------------------ 2.203 L 0.83 C=120 PT 22.01 ( 40) Q 39.98 F=T F 11.60 PE -0.36 RN T 12.43 0.0126 PF 0.16 60 80 2.203 L 94.67 C=120 PT 21.81 ( 80) Q 39.98 F=0 F 0.00 PE 0.00 BL T 94.67 0.0126 PF 1.19 20 60 2.203 L 0.83 C=120 PT 23.00 ( 60) Q 39.98 F=T F 11.60 PE 0.36 RN T 12.43 .0.0126 PF 0.16 PT 23.52 C 20) 7939 ------------------ 2.203 L 0.83 C=120 PT 21.52 ( 39) Q 52.29 F=T F 11.60 PE -0.36 RN T 12.43 0.0208 PF 0.26 SUBMITTAL SERIAL NO:2932HY7 08-09-2012 PAGE 10 PIZZA PORT ROOF CALC .495/2000 (PEAKED) Location Flow Pipe. Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 59 79 2.203 L 94.67 C=120 PT 21.42 ( 79) Q 52.29 F=0 .F 0.00 PE 0.00 BL T 94.67 0.0208 PF 1.97 19 59 2.203 L 0.83 C=120 PT 23.39 ( 59) Q 52.29 F=T F 11.60 PE 0.36 RN T 12.43 0.0208 PF 0.26 PT 24.01 ( 19) 74 34 ------------------- 2.203 L 0.83 C=120 PT 27.03 ( 34) Q 83.89 F=T F 11.60 PE RN T 12.43 0.0498 PF 0.62 54 74 2.203 L 214.17 C=120 PT 27.29 ( 74) Q 83.89 F=0 F 0.00 PE 0.00 EL T 214.17 0.0498 PF 10.67 14 54 2.203 L 0.83 C=120 PT 37.96 ( 54) Q 83.89 F=T F 11.60 PE 0.36 RN T 12.43 0.0498 PF 0.62 PT 38.94 ( 14) 73 33 -- -- - 2.203 ,L 0.83 C=120 PT 29.20 ( 33) Q 83.56 F=T F 11.60 PE -0.36 RN T 12.43 0.0494 PF 0.61 53 73 2.203 L 214.17 C=120 PT 29.45 ( 73) Q 83.56 F=0 . F 0.00 PE 0.00 EL T 214.17 0.0494 PF 1.0.58 13 53 2.203 L 0.83 C=120 PT 40.03 ( 53) Q 83.56 F=T F 11.60 PE . 0.36 RN . T 12.43 .0.0494 PF 0.61 PT 41.00 ( 13) 72 32 ------------------ 2.203 L 0.83 C=120 PT 30.34 ( 32) Q 88.32 F=T F 11.60 . PE RN T 12.43 0.0548 PF 0.68 52 72 2.203 L 214.17 C=120 PT 30.66 ( 72) Q 88.32 F=0 F 0.00 PE 0.00 BL T 214.17 0..054.8 PF 11.74 12 52 2.203 L 0.83 C=120 PT 42.40 ( 52) Q 88.32 F=T F 11.60 PE. 0.36 RN . T 12.43 0.0548 PF 0.68 PT 43.44 ( 12) SUBMITTAL SERIAL NO:2932HY7 08-09-2012 PAGE 11 PIZZA PORT ROOF CALC .495/2000 (PEAKED) Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 51 -------------------- 30 2.203 L 109.75 C=120 PT 41.04 ( 30) Q 61.49 F=0 F 0.00 PE 0.00 BI, T 109.75 0.0280 PF 3.07 11 51 2.203 L 0..83 C=120 PT 44.11 ( 51) Q 61.49 F=T F 11.60 PE 0.36 RN T 12.43 0.0280 PF 0.35 5 11DQ 54.83 4.310 L 6.00 C=120 PT 44.82 ( 11) Q 116.32 F=0 F 0.00 PE 0.00 CM1 T 6.00 0.0035 PF 0.02 4 5DQ 1135.02 4.310 L 16.58 C=120 PT 44.84 ( 5) Q 1251.35 F=T F 22.30 PE 0.00 FM T 38.88 0.2811 PF 10.93 3 4 4.310 L 25.50 C=120 PT .55.77 ( 4) Q 1251.35 F=E F 9.48 PE 11.05 FR T 34.98 0.2811 PF 9.83 2 3DQ 100.00 4.310 L 2.00 C=120 PT 76.65 ( 3) Q 1351.35 F=2E F 18.96 PE 0.43 MA T 20.96 0.3241 PF 6.79 COMMENT: 5 PSI LOSS FOR DDCA SHOWN AS ELEVATION 1 2 7.758 L 200.00 C=150 PT 83.87 ( 2) Q 1351.35 F=T,4E/3E F 243.16 PE 5.00 UN T 443.16 0.0123 PF 5.45 0 1DQ 400.00 7.758 L 210.00 C=150 PT 94.32 ( 1) Q 1751.35 F=0 F 0.00 PE 0.00 UN T 210.00 0.0198 PF 4.16 PT 98.48 ( 0) Ac' f (OG EPIC FIRE PROTECTION, INC. 765 TURTLE POINT WAY yu SAN MARCOS, CA 92069 (760) 310-6122 FAX (760) 798-0556 Hydraulic Design information Sheet Name: PIZZA PORT - MEZZANINE SYSTEM Date: 8-4-12 Location: 2730 GATEWAY RD. CARLSBAD Building: NEW System No. 1 OF 1 Contractor: EPIC FIRE PROTECTION, INC. Contract No. Calculated By: RAB Drawing No. 2 OF 2 Construction: Z Combustible LI Non-Combustible Ceiling Height 27 Ft. SYSTEM DESIGN - NFPA 13: []Light Hazard Ordinary Hazard Group 1 [] 2 [1] 1 3 0 Extra Hazard LI NFPA 231 LI NFPA 231C: Figure: Curve: LI Other (Specify) Li] Specific Ruling Made By Date Mea of Sprinl1et Opation 1500 System T'e Density .15 M Wet LI Dry LI Deluge LI Pre-Action Area Per Sprinkler 18.X 18 Sprinkler or Nozzle Hose Allowance GPM: Inside 100 Make TYCO Model EC-11 Hose Allowance GPM: Outside 150 Size %" K-Factor: 11.2 Rack Sprinkler Allowance Temperature Rating 155 1J Pil W (Si ItIJ I V.1 3' GPM Required 590.37 PSI Required 95.98 At Base of Riser "C" Factor Used: Overhead 120 Underground 150 UTAT? 4ZTTDDTV Water Flow Test Pump Data Tank or Reservoir Date & Time 6-19-12 Rated Capacity Capacity Static PSI 128 At PSI Elevation Residual PSI 121 Elevation GPM Flowing 1300 Well Elevation 0 1 Proof Flow GPM Location SITE Source of Information EPIC FIRE AND CARLSBAD WATER DIST COMMODITY STORAGE Commodity FOOD PREP Class Location * Storage Height Area Aisle Width Storage Method: Solid Piled % Palletized % Rack Rack LI Single Row LI Conventional Pallet LI Double Row LI Slave Pallet 0 Multiple Row LI Open Flue Spacing In Inches Longitudinal ___ Transverse - Horizontal Barriers Provided LI Automatic Storage LI Encapsulated LI Solid Shelving LI Non-Encapsulated Clearance From Top of Storage to Ceiling Ft. In. PIZZAPORT MEZZ CALC .15/1500 Sigma Dynamics Corporation 7700 Supply / Demand Graph Margin Pressure 9.97 PSI Flow 1116.60 GPM - N185 1Ffl flfl 4fl ThO 900 1050 1200 1350 151 Water Flow (GPM) System Demand.. Sprinkler Demand 101.79 PSI @ 490.37 GPM Additional Flows 250.00 GPM Hose at Source 0.00 GPM Total Demand 103.01 PSI @ 740.37 GPM Water Supply.. Static 115.20 PSI Residual 108.90 PSI @ 1300.00 GPM Elevation 0.00 PSI 250 240 230 220 210 200 190 180 170 160 150 140 130 120 110 100 90 80 70 60 50 40 30 20 10 SUBMITTAL SERIAL NO:2932HY7 08-09-2012 PAGE 1 PIZZA PORT MEZZ CALC .15/1500 FLOW TEST RESULTS Water Supply STATIC 115.20 PSI RESIDUAL 108.90 PSI @ 1300.00 GPM CITY PRESSURE AVAILABLE AT 740.4 GPM SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW K-FACTOR PRESSURE 220 57.79 49.00 11.20 26.63 221 55.96 49.00 11.20 24.97 222 .55.45 49.00 11.20 24.51 223 52.53 49.00 11.20 21.99 224 54.12 49.00 11.20 23.35 225 51.26 49.00 11.20 20.95 226 49.00 49.00 11.20 19.14 227 58.68 49.00 11.20 27.45 228 55.57 49.00 11.20 24.62 112.98 PSI TOTAL WATER REQUIRED FOR SYSTEM OUTFLOWS AT 1 OUTFLOWS AT 3 TOTAL WATER REQUIREMENT PRESSURE REQUIRED AT 0 MAXIMUM PRESSURE UNBALANCE IN LOOPS MAXIMUM VELOCITY FROM 200 TO 202 490.37 GPM 150.00 GPM 100.00 GPM 740.37 GPM 103.01 PSI 0.00 PSI 27.42 FPS SUBMITTAL SERIAL NO:2932HY7 08-09-2012 PAGE 2 PIZZA PORT MEZZ CALC .15/1500 Location • Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 216 226 1.080 L 5.00 C=120 PT 19.14 (226) Q 49.00 F=T/E F 8.10 PE -0.43 AO T 13.10 0.5926 PF 7.76 PT 26.47 (216) 215 ------------------ 228 2.203 L 12.00 C=120 PT 24.62 (228) Q 55.57 F=0 F 0.00 PE 0.00 EN T 12.00 0.0232 PF 0.28 213 215DQ 51.26. 2.203 L 16.00 C=120 PT 24.90 (215) Q 106.84 F=0 F 0.00 PE 0.00 BN T 16.00 0.0779 PF 1.25 216 213DQ 52.53 2.203 L 2.00 C=120 PT 26.15 (213) Q 159.36 F=0 F 0.00 PE 0.00 BN T 2.00 ,0.1631.PF 0.33 211 216D0 49.00 2.203 L 12.00 C=120 PT 26.48 (216) Q 208.36 F=0 F 0.00 PE 0.00 EN T 12.00 0.2679 PF 3.21 PT 2.9.69 (211) 215 ------------------ 225 1.080 L 1.00 C=120 PT 20.95 (225) Q 51.26 F=T F 5.80 PE -0.43 AO T 6.80 0.6442 PF 4.38 T 4.90 (215) 214 224 1.080 L 1.00 C=120 PT 23.35 (224) Q 54.12 F=T F 5.80 PE -0.43 AO T 6.80 0.7122 PF 4.84 PT 21.76 (214) 213 ------------------ 223 1.080 L 1.00 C120 PT 21.99 (223) Q 52.53 F=T F 5.80 PE -0.43 AO T 6.80 0.6739 PF 4.58 PT 26.14 212 ------------------ 222 1.080 L 1.00 C=120 PT 24.51 (222) Q 55.45 F=T F 5.80 PE -0.43 AO T 6.80 0.7448 PF 5.06 PT 29.14 211 ------------------ 221 1.080 L 1.00 C=120 PT 24.97 (221) Q 55.96 F=T F 5.80 PE -0.43 AO T 6.80 0.7577 PF 5.15 203 211DQ 208.36 2.203 L 4.00 C=120 PT 29.69 (211) Q 264.32 F=T F 11.60 PE 0.00 BN T 15.60 0.4160 PF 6.49 PT 36.18 (203) SUBMITTAL SERIAL NO:2932HY7 08-09-2012. PAGE 3 PIZZA PORT MEZZ CALC .15/1500 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 210 ------------------ 220 1.080 L 1.00 C=120 PT 26.63 (220) Q 57.79 F=T F 5.80 PE -0.43 AO T 6.80 0.8042 PF 5.47 -- PT 31.67 (210) 214 227 2.203 L 12.00 C=120 PT 27.45 (227) Q 58.68 F=0 F 0.00 PE 0.00 BN T 12.00 0.0257 PF 0.31 212 214DQ 54.12 2.203 L 16.00 C=120 PT 27.76 (214) Q 112.80 F=0 F 0.00 PE 0.00 BN T 16.00 0.0861 PF 1.38 210 212DQ 55.45 2.203 L 14.00 C=120 PT 29.14 (212) Q 168.25 F=0 F 0.00 PE 0.00 EN T 14.00 0.1804 PF 2.53 201 210DQ 57.79 2.203 L 4.00 C=120 PT 31.67 (210) Q 226.04 F=T F 11.60 PE 0.00 EN T 15.60 0.3115 PF 4.86 PT 36.53 (201) 37 200 - - 2.703 L 2.50 .C=120 PT 7L.51 (200) Q 218.89 F=0 F 0.00 PE O.00 CM2 T 2.50 0.1084 PF 0.27 38 37DQ -58.01 2.703 L 10.00 C=120 PT 71.78 ( 37) Q 160.89 F=0 F 0.00 PE 0.00 CM2 T 10.00 0.0613 PF 0.61 39 38DQ -54.38 2.703 L 10.67 C=120 PT 72.39 ( 38) Q 106.50 F=0 F 0.00 1 PE 0.00 CM2 T 10.67 0.0286 PF 0.31 40 39DQ -30.81 2.703 L 12.00 C=120 PT 72.70 ( 39) Q 75.70 F=0 F 0.00 PE 0.00 CM2 T 12.00 0.0152 PF 0.18 41 40DQ -23.55 2.703 L 12.00 C=120 PT 72.88 ( 40) Q 52.14 F=0 F 0.00 PE 0.00 CM2 T 12.00 0.0076 PF 0.09 42 41DQ -19.07 2.703 L 12.00 C=120 PT 72.97 ( 41) Q 33.07 F=0 F 0.00 PE 0.00 CM2 T 12.00 0.0033 PF 0.04 SUBMITTAL SERIAL NO:2932HY7 PIZZA PORT MEZZ CALC .15/1500 Location Flow Pipe Fittings in Size & From To GPM IN Devices 43 42DQ -16.86 2.703 0 16.21 F=0 CM2 83 43 2.203 Q 16.21 F=T RN 63 83 2.203 Q 16.21 F=0 BL 23 63 2.203 Q 16.21 FT RN 22 23 2.703 Q 16.21 F=0 CM1 21 22DQ 16.86 2.703 Q 33.07 F=0 CM1 20 21DQ 19.07 2.703 Q 52.14 F=0 CM1 19 20DQ 23.55 2.703 Q 15.70 F=0 CM1 18 19DQ 30.81 2.703 Q 106.50 F=2E CM1 17 18DQ 54.38 4.310 Q 160.89 F=0 CM1 16 17DQ 58.01 4.310 Q 218.89 F=0 CMI 15 16DQ 51.84 4.310 Q 270.74 F=0 CM1 08-09-2012 PAGE 4 Equiv Friction Pressure Length Loss Summary Ft PSI/Ft PSI L 12.00 C=120 PT 73.01 ( F 0.00 PE 0.00 T 12.00 0.0009 PF 0.01 L 0.83 C=120 PT 73.02 ( F 11.60 PE -0.36 T 12.43 0.0024 PF 0.03 L 94.67 C=120 PT 72.69 ( 83) F 0.00 PE 0.00 T 94.67 0.0024 PF 0.23 L 0.83 C=120 PT 72.92 ( 63) F 11.60 PE 0.36 T 12.43 0.0024 PF 0.03 L 12.00 C=120 PT 73.31 ( 23) F 0.00 PE 0.00 T 12.00 0.0009 PF 0.01 L 12.00 C=120 P73.32 ( 22) F 0.00 PE 0.00 T 12.00 0.0033 PF 0.04 L 12.00 C=120 PT 73.36 ( 21) F 0.00 PE 0.00 T 12.00 0.0076 PF 0.09 L 12.00 C=120 PT 73.45 ( 20) F 0.00 PE 0.00 T 12.00 0.0152 PF 0.18 L 130.17 C=120 PT 73.63 ( 19) F 13.20. PE 0.00 T 143.37 0.0286 PF 4.10 L 10.00 C=120 PT 77.73 ( 18) F 0.00 PE 0.00 T 10.00 0.0063 PF 0.06 L 12.00 C=120 PT 77.79 C 17) F 0.00 PE 0.00 T 12.00. 0.0112 PF 0.13 L 12.00 C=120 PT 77.92 ( 16) F 0.00 PE 0.00 T 12.00 0.0166 PF 0.20 SUBMITTAL SERIAL NO:2932HY7 08-09-2012 PAGE 5 PIZZA PORT MEZZ CALC .15/1500 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 14 15DQ 45.10 4.310 L 12.00 C=120 PT 78.12 ( 15) Q 315.84 F=0 F 0.00 PE 0.00 CM1 T 12.00 0.0220 PF 0.26 13 14DQ 41.14 4.310 L 12.00 C=120 PT 78.38 ( 14) Q 356.97 F=0 F 0.00 PE 0.00 CM1 T 12.00 0.0276 PF 0.33 12 13]JQ 39.80 4.310 L 12.00 C=120 PT 78.71 ( 13) Q 396.77 F=0 F 0.00 PE 0.00 CM1 T 12.00 0.0336 PF 0.40 5 12DQ 40.74 4.310 L 6.00 C=120 PT 79.11 ( 12) Q 437.51 F=0 F 0.00 PE 0.00 CM1 T 6.00 0.0402 PF 0.24 PT 79.35 C 5) 78 ------------------- 38 2.203 L 0.83 C=120 PT 72.39 ( 38) Q 54.38 F=T F 11.60 PE -0.36 RN T 12.43 0.0223 PF 0.28 127 78 2.203 L 57.93 .C=120 PT 72.31 ( 78) Q 54.38 F=0 F 0.00 PE 0.00 BL T 57.93 0.0223 PF 1.29 126 127 2.203 L 8.00 C=120 PT 73.60 (127) Q 54.38 F=0 F 0.00 PE 0.00 EL T 8.00 0.0223 PF 0.18 .125 126 2.203 L 8.00 C=120 PT 73.78 (126) Q 54.38 F=0 F 0.00 PE 0.00 BL T 8.00 0.0223 PF 0.18 124 125 2.203 L 8.00 C=120 PT 73.96 (125) Q 54.38 F=0 F 0.00 PE 0.00 BL T 8.00 0.0223 PF 0.18 123 124 2.203 L 8.00 C=120 PT 74.14 (124) Q 54.38 F=0 F 0.00 PE 0.00 BL T 8.00 0.0223 PF .0.18 122 123 2.203 L 8.00 C=120 PT 74.32 (123) Q 54.38 F=0 F 0.00 PE 0.00 EL T 8.00 0.0223 PF 0.18 121 122 2.203 L 8.00 C=120 PT 74.50 (122) Q 54.38 F=0 F 0.00 PE 0.00 EL T 8.00 0.0223 PF 0.18 SUBMITTAL SERIAL NO:2932HY7 PIZZA PORT MEZZ CALC .15/1500 Location Flow Pipe Fittings in. Size From To GPM IN Devices 58 121 2.203 Q 54.38 F0 BL 18 58 2.203 Q 54.38 F=T RN 77 37 ------------------ 2.203 Q 58.01 F=T RN 120 77 2.203 Q 58.01 F=0 BL 119 120 2.203 Q 58.01 F=0 BL 118 119 2.203 Q 58.01 F=0 BL 117 118 2.203 Q 58.01 F=0 BL 116 117 2.203 Q 58.01 F=0 EL 115 116 2.203 Q 58.01 F=0 BL 114 115 2.203 Q 58.01 F=0 BL 57 114 2.203 Q 58.01 F=0 EL 17 57 2.203 Q 58.01 F=T RN 08-09-2012 PAGE 6 Equiv Friction. Pressure Length Loss Summary Ft PSI/Ft PSI L 108.24 C=120 PT 74.68 (121) F 0.00 PE 0.00 T 108.24 0.0223 PF 2.41 L 0.83 C=120 PT 77.09 ( 58) F 11.60 ' PE 0.36 T 12.43 0.0223 PF 0.28 PT 77.73 ( 18) L 0.83 C=120 PT 71.78 ( 37) F 11.60 PE -0.36 T 12.43 0.0252 PF 0.31 L 57.93 C=120 PT 71.73 ( 77) F 0.00 PE 0.00 T 5,7.93 0.0252 PF 1.46 L 8.00 C=120 PT 73.19 (120) F 0.00 PE 0.00 T 8.00 '0.0252 PF 0.20 L 8.00 C=120 PT, 73.39 (119) F 0.00 PE 0.00 T 8.00 0.0252'PF 0.20 L 8.00 C=120 PT 73.59 (118) F 0.00 PE 0.00 T 8.00 0.0252 PP' 0.20 L . 8.00 C=120 PT 73.79 (117) F 0.00 PE 0.00 T 8.00 0.0252 PF 0.20 L 8.00 C=120 PT 73.99 (116) F 0.00 PE 0.00 T 8.00 0.0252 PF 0.20 L 8.00 C=120 PT 74.19 (115) F 0.00 ' PE 0.00 T 8.00 0.0252 PF 0.20 L 108.24 C=120 PT 74.39 (114) F 0.00 PE 0.00 T 108.24 0.0252 PF 2.73 L 0.83 C=120 PT 77.12 ( 57) F 11.60 PE 0.36 T 12.43 .0.0252 PF 0.31 PT .77.79 ( 17) SUBMITTAL SERIAL NO:2932HY7 08-09-2012 PAGE 7 PIZZA PORT MEZZ CALC .15/1500 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 36 200 ------------------ 2.703 L 9.50 C=120 PT 71.51 (200) Q 271.47 F=0 F 0.00 PE 0.00 CM2 T 9.50 0.1614 PF 1.53 76 36DQ -219.63 2.203 L 0.83 C=120 PT 73.04 ( 36) Q 51.84 F=T F 11.60 PE -0.36 RN T 12.43 0.0204 PF 0.25 113 76 2.203 L 57.93 C=120 PT 72.93 ( 76) Q 51.84 F=0 F 0.00 PE 0.00 EL T 57.93 0.0204 PF 1.18 112 113 2.203 L 8.00 C=120 PT 74.11 (113) Q 51.84 F=0 F 0.00 PE 0.00 BL T 8.00 0.0204 PF 0.16 111 112 2.203 L 8.00 C=120 PT 74.27 (112) Q 51.84 F=0 F 0.00 PE 0.00 EL T 8.00 0.0204 PF 0.16 110 111 2.203 L 8.00 C=120 PT 74.43 (111) Q 51.84 F=0 F 0.00 PE 0.00 EL T 8.00 0.0204 PF 0.16 109 110. 2.203 L 8.00 C=120 PT 74.59 (110) Q 51.84 F=0 F 0.00 PE 0.00 EL T 8.00 0.0204 PF 0.16 108 109 2.203 L 8.00 C=120 PT 74.75 (109) Q 51.84 F=0 F 0.00 PE 0.00 EL T 8.00 0.0204 PF 0.16 107 108 2.203 L 8.00 C=120 PT 74.91 (108) Q 51.84 F=0 F 0.00 PE 0.00 BL T 8.00 0.0204 PF 0.16 56 107 2.203 L 108.24 C=120 PT 75.07 (107) Q 51.84 F=0 F 0.00 PE 0.00 BL T 108.24 0.02.04 PF 2.21 16 56 2.203 L 0.83 C=120 PT 77.28 ( 56) Q 51.84 F=T F 11.60 PE 0.36 RN T 12.43 0.0204 PF 0.25 PT 77.89 ( 16) 35 36 - - 2.703 L 12.00 C=120 ' PT 73.04 ( 36) Q 219.63 F=0 F 0.00 PE 0.00 CM2 T 12.00 0.1091 PF 1.31 SUBMITTAL SERIAL NO:2932HY7 PIZZA PORT MEZZ CALC .15/1500 Location Flow Pipe Fittings in Size & From To GPM IN Devices 75 35DQ -174.53 2.203 O 45.10 F=T RN 106 75 2.203 Q 45.10 F=0 BL 105 106 2.203 Q 45.10 F=0 EL 104 105 2.203 Q 45.10 F=0 BL 103 104 2.203 Q 45.10 F=0 BL 102 103 2.203 Q 45.10 F=0 BL 101 102 2.203 Q 45.10 F=0 BL 100 101 2.203 Q 45.10 F=0 DL 55 100 2.203 Q 45.10 F=0 BL 15 55 2.203 Q 45.10 F=T RN 34 35 ------------------ 2.703 Q 174.53 .F=0 CM2 33 34DQ -41.14 2.703 Q 133.39 CM2 08-09-2012 PAGE 8 Equiv Friction Pressure Length Loss Summary Ft PSI/Ft PSI L 0.83 C120 PT 74.35( 35) F 11.60 PE -0.36 T 12.43 0.0158 PF 0.20 L 57.93 C=120 PT 74.19 ( 75) F 0.00 PE 0.00 T 57.93 0.0158 PF 0.92 L 8.00 C=120 PT 75.11 (106) F 0.00 PE 0.00 T 8.00 0.0158 PF 0.13 L 8.00 C=120 PT 75.24 (105) F 0.00 PE 0.00 T 8.00 0.0158 PF 0.13 L 8.00 C=120 PT 75.37 (104) F 0.00 PE 0.00 T 8.00 0.0158 PF 0.13 L 8.00 C=120 PT 75.50 (103) F 0.00 PE 0.00 T 8.00 0.0158 PF 0.13 L 8.00 C=120 PT 75.63 (102) F 0.00 PE 0.00. T 8.00 0.0158 PF 0.13 L 8.00 C=120 PT 75.76 (.101) F 0.00 PE 0.00 T 8.00 0.0158 PF 0.13 L 108.24 C=120 PT 75.89 (100) F 0.00 PE 0.00 .T 108.24 0.0158 PF 1.71 L 0.83 C=120 PT 77.60 ( 55) F 11.60 PE 0.36 T 12.43 0.0158 PF 0.20 PT 78.16 ( 15) L 12.00, C=120 PT 74.35 ( 35) F 0.00 PE 0.00 T 12.00 0.0713 PF 0.86 L 12.00 C=120 PT 75.21 ( 34) F 0.00 PE .0.00 T 12.00 0.0434 PF 0.52 SUBMITTAL SERIAL NO:2932HY7 08-09-2012 PAGE 9 PIZZA PORT MEZZ CALC .15/1500 Location Flow Pipe Fittings in Size & From To GPM IN Devices 32 33DQ -39.80 2.703 Q 93.60 F=0 CM2 31 32DQ -40.74 2.703 Q 52.85 F=0 CM2 71 31 2.203 Q 52.85 F=T RN 30 71 2.203 Q 52.85 F=0 EL 50 30DQ -27.94 2.203 Q 24.91 F=E,T EL 10 50 2.203 Q 24.91 F=T RN 11 10 4.310 Q 24.91 F=0 CM1 82 42 ------------------ 2.203 Q 16.86 F=T RN 62 82 2.203 Q 16.86 F=0 EL 22 62 2.203 Q 16.86 F=T RN 81 41 ------------------ 2.203 Q 19.07 F=T RN 61 81 2.203 Q 19.07 F0 EL Equiv Friction Pressure Length Loss . Summary Ft PSI/Ft PSI L 12.00 C=120 PT 75.73 ( 33) F 0.00 PE 0.00 T 12.00 0.0225 PF 0.27 L 12.00 Cr120 PT 76.00 ( 32) F 0.00 PE 0.00 T 12.00 0.0078 PF 0.09 L 0.83 C=120 PT 76.09 ( 31) F 11.60 PE -0.36 T 12.43 0.0212 PF 0.26 L 104.42 C=120 PT 75.99 ( 71) F 0.00 PE 0.00 T 104.42 0.0212 PF L 121.75 C=120 PT 78.20 ( 30) F 16.40 PE 0.00 T 138.15 0.0053 PF 0.73 L 0.83 C=120 PT 78.93 ( 50) F 11.60 PE 0.36 T 12.43 0.0053 PF 0.07 L 12.00 C=120 PT 79.36 ( F 0.00 PE 0.00 T 12.00 0.0002 PF 0.00 PT 79.36 ( L 0.83 C=120 PT 73.01 ( 42) F .11.60 PE -0.36 T 12.43 0.0026 PF 0.03 L 94.67 C=120 PT 72.68 ( 82) F .0.00 PE. 0.00 T . 94.67 0.0026 PF 0.25 L 0.83 C=120 PT 72.93 ( 62) F 11.60 PE 0.36 T 12.43 0.0026 PF 0.03 PT 73.32 C 22) L 0.83 C=120 PT 72.97 ( 41) F 11.60 PE -0.36 T 12.43 0.0032 PF 0.04 L 94.67 C=120 PT 72.65 ( 81) F 0.00 PE 0.00 T 94.67 0.0032 PF . 0.30 SUBMITTAL SERIAL NO:2932HY7 PIZZA PORT MEZZ CALC .15/1500 Location Flow Pipe Fittings in Size & From To GPM IN Devices 21 61 2.203 Q 19.07 F=T S RN 80 40 ------------------ 2.203 Q 23.55 F=T RN 60 80 2.203 Q 23.55 F=0 BL 20 60 2.203 Q 23.55 F=T RN 79 ------------------ 39 2.203 Q 30.81 F=T RN 59 79 2.203 Q 30.81 F=0 BL 19 59 2.203 Q 30.81 F=T RN 74 34 ------------------ 2.203 Q 41.14 F=T RN 54 74 2.203 Q 41.14 F=0 EL 14 54 2.203 Q 41.14 F=T RN 73 33 ------------------ 2.203 Q 39.80 F=T RN 08-09-2012 PAGE 10 Equiv Friction Pressure Length Loss Summary Ft PSI/Ft PSI L 0.83 C=120 PT 72.95 ( 61) F 11.60 PE 0.36 T 12.43 0.0032 PF 0.04 PT 73.35 ( 21) L 0.83 C=120 PT 72.88 ( 40) F 11.60 PE -0.36 T 12.43 0.0047 PF 0.06 L 94.67 C=120 PT 72.58 ( 0) F 0.00 PE 0.00 T 94.67 0.0047 PF 0.44 L 0.83 C=120 PT 73.02 ( 60) F 11.60 PE 0.36 T 12.43 0.0047 PF 0.06 PT 73.44 ( 20) L 0.83 C=120 PT 72.69 ( 39) F 11.60 1218 -0.36 T 12.43 0.0078 PF 0.10 L 94.67 C=120 PT 72.43 ( 79) F 0.00 PE 0.00 T 94.67 0.0078 PF 0.74 L 0.83 C=120 PT 73.17 ( 59) F 11.60 PE 0.36 T 12.43 0.0078 PF 0.10 PT 73.63 ( 19) L 0.83 C=120 PT 75.20 ( 34) F 11.60 PE -0.36 T 12.43 0.0133 PF 0.17 L 214.17 C=120 PT 75.01 ( 74) F 0.00 PE 0.00 T 214.17 0.0133 PF 2.85 L 0.83 C=120 PT 77.86 ( 54) F 11.60 PE 0.36 T 12.43 0.0133 PF 0.17 PT 78.39 ( 14) L 0.83 C=120 PT 75.72 ( 33) F 11.60 PE -0.36 T 12.43 0.0125PF 0.16 SUBMITTAL SERIAL NO:2932HY7 PIZZA PORT MEZZ CALC .15/1500 Location Flow Pipe Fittings in Size & From To GPM IN Devices 53 73 2.203 Q 39.80 F=0 EL 13 53 2.203 Q 39.80 F=T RN 72 - 32 2.203 Q 40.74 F=T RN 52 72 2.203 Q 40.74 F=0 BL 12 52 2.203 Q 40.74 FT RN 51 ------------------ 30 2.203 Q 27.94 F=0 EL 11 51 2.203 Q 27.94 F=T RN 5 11DQ 24.91 4.310 Q 52.85 F=0 CM1 ------------------ 202 203 2.703 Q 264.32 F=0 FM 08-09-2012 PAGE 11 Equiv Friction Pressure Length Loss Summary Ft PSI/Ft PSI L 214.17 C=120 PT 75.52 ( 73) F 0.00 PE 0.00 T 214.17 0.0125 PF 2.68 L 0.83 C=120 PT 78.20 ( 53) F 11.60 PE 0.36 T 12.43 0.0125 PF 0.16 PT 78.72 ( 13) L 0.83 C=120 PT 75.99 ( 32) F 11.60 PE -0.36 T 12.43 0.0131 PF 0.16 L 214.17 C=120 PT 75.79 ( 72) F 0.00 PE 0.00 T 214.17 0.0131 PF 2.81 L 0.83 C=120 PT 78.60 ( 52) F 11.60 PE 0.36 T 12.43 0.0131 PF 0.16 PT 79.12 ( 12) L 109.75 C=120 PT 78.20 ( 30) F 0.00 PE 0.00 T 109.75 0.0065 PF 0.71 L 0.83 C=120 PT 78.91 ( 51) F 11.60 PE 0.36 T 12.43 0.0065 PF 0.08 L 6.00 C=120 PT 79.35 ( 11) F 0.00 PE 0.00 T 6.00 0.0008 PF 0.00 PT 79.35 ( 5) L 9.00 Cr120 PT 36.17 (203) F 0.00 PE 0.00 T 9.00 0.1536 PF 1.38 PT 37.55 (202) 202 201 2.703 Q 226.04 FM 200 202DQ 264.32 2.703 Q 490.37 FM L 9.00 C=120 PT 36.52 (201) F=0 F 0.00 PE 0.00 T 9.00 0.1150 PF 1.04 L 16.50 C=120 PT 37.56 (202) F=2T,E F 40.00 PE 6.72 T 56.50 0.4820 PF 27.23 PT 71.51 (200) SUBMITTAL SERIAL NO:2932HY7 PIZZA PORT MEZZ CALC .15/1500 Location Flow Pipe Fittings in Size & From To GPM IN Devices 08-09-2012 PAGE 12 Equiv Friction Pressure Length Loss Summary Ft PSI/Ft PSI 4 ------------------ 5 4.310 L 16.58 C=120 PT 79.36 ( 5) Q 490.37 F=T F 22.30 PE 0.00 FM T 38.88 0.0497PF 1.93 3 4 4.310 L 25.50 C=120 PT 81.29 ( 4) Q 490.37 F=E F 9.48 PE 11.05 FR T 34.98 0.0497 PF 1.74 2 3DQ 100.00 4.310 L 2.00 C=120 PT 94.08 ( 3) Q 590.37 F=2E F 18.96 PE 0.43 MA T 20.96 0.0700 PF 1.47 COMMENT: 5 PSI LOSS FOR DDCA SHOWN AS ELEVATION 1 2 7.758 L 200.00 C=150 PT 95.98 ( 2) O 590.37 FT,4E/3E F 243.16 PE 5.00 UN T 443.16 0.0026 PF 1.15 0 1DQ 150.00 7.758 L 210.00 C=150 PT 102.13 ( 1) Q 740.37 F=0 F 0.00 PE 0.00 UN T 210.00 0.0040 PF 0.84 PT 102.97 ( 0) A6 ( ~m5- 1770 C=m MATERIAL DATA SUBMITTAL PIZZA PORT 2730 GATEWAY R. CARLSSA, CA EPIC FIRE PROTECTION, INC. 75 TURTLE POINT WAY SAN MARCOS, CA 9200 (700)310-0122 FAX(700)7-98-0556 Temperature Ratings Refer to Table A Finish Natural Brass. Example 1: NFPA 13 provides ceil- ing only protection (that is, no in-rack sprinklers) criteria using open frame (that is, no solid shelves) single, double, multiple-row, or portable rack storage (without the need for in-rack sprinkler protection) of cartoned or uncartosed unexpanded Group A or B plastics, or, cartoned expanded Group A or B plas-tics, with: a storage height of up to 20 feet (6,1 m); a maximum ceiling height of 27 feet (8,2 m); a minimum deflector to top of storage clearance of 18 inches (457 mm); a minimum design density of 0.60 gpm/1t0 (24,4 mm/mm); a minimum residual (flowing) pressure of 7 psi (0,5 bar); a minimum design area of 2000 ft' (186 m') for wet systems or 2600 ftc (242 mu) for dry pipe systems Example 2: NFPA 13 provides ceil- ing only protection (that is, no in-rack sprinklers) criteria using open frame (that is, no solid shelves) single, double, multiple-row, or portable rack storage (without the need for in-rack sprinkler protection) of cartoned or uncartoned unexpanded Group A or B plastics, or, cartoned expanded Group A or B plas-tics, with: a storage height of up to 25 feet (7,6 m); a maximum ceiling height of 30 feet Al m(; a minimum deflector to top of storage clearance of 18 inches (457 mm); a minimum design density of 0,80 gpm/ft0 (32,6 mm/mm); a minimum residual (flowing) pressure of 7 psi (0,5 bar); a minimum design area of 2000 fri (186 m') for wet systems or 4500 ft0 (418 mu) for dry pipe systems FM Approval Requirements The TYCO 16.8 K-factor, Model 1<17-231 )TY7151( Upright Sprinklers may be in- stalled in accordance with the applica- ble "control mode density/area" guide-lines provided by Factory Mutual. (FM guidelines may differ from UL and C-UL Listing criteria.) 800-381-9312 tu~07 Technical Services 1 +1_401-781-8220 ww.tyco-fire.com Model K17-231 — 16.8 K-factor Upright and Pendent Sprinklers Standard Response, Standard Coverage General Esm The 16.8 K-factor, Model 1<17-231 Up- Description right and Pendent Sprinklers described The TYCO 16.8 K-factor, Model herein must be installed and maintained in compliance with this document and K17-231, Standard Response, Standard with the applicable standards of the Na- Coverage, Upright and Pendent Spris- tional Fire Protection Association, in ad- kiers (Ref. Figure 1) are automatic apr10- dition to the standards of any authori- klers of the frangible bulb type. They ties ha ring jurisdiction. Failure to do so are "standard response spray sprin- may impair the performance of these kiers" which produce a hemispherical devices. water distribution pattern below the deflector. The owner is responsible for maintain- ing their fire protection system and do- The 16.8 K-factor, 1<17-231 Sprinklers vices in proper operating condition. were subjected to fall scale, high-piled The installing contractor or manufac- storage, fire tests to qualify their use lurer should be contacted with any in lieu of 8.0 or 11.2 K-Factor standard questions. spray sprinklers for the protection of sign-piled Storage. Higher flow rates can be achieved at Model/Sprinkler i much lower pressures with the 16.8 K- Identification factor, K17-231 Sprinklers - making their use highly advantageous in high Number (SIN) density applications, such as the pro- tection of high-piled storage. 1Y7151 -Upright, 16.8K Applications for the 16.8 K-factor, Mod- TY7251 -Pendent, 16.8K el K17-231 Pendent and Upright Sprin- klers are expanding beyond the cur- TY71 51 is a redesignation for C7151, rent listings/approvals. For information G1888, and S8040. regarding research fire tests which may TY7251 is a redesignation for C7251, be acceptable loan authority having (a- G1889, and S8041, risdiction, please contact the Technical Services Department, Technical Data Approvals UL and C-UL Listed. FM and NYC Ap-proved. (Specific details for laboratory listings and approvals given in Table A. The approvals apply to the service con-ditions indicated in the Design Criteria IMPORTANT section.) Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and installation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. TFP3S2 Page 2 of 4 SPRINKLER FINISH TYPE TEMPERATURE BULB LIQUID NATURAL BRASS 155'F i6ECl Red UPRIGHT 1,2,3,4 200F (93C) Green K=16.8 (TY7151) 286F (141-C) Blue I55"F IflECI Red PENDENT K=16.8 (TY7251) 1,2,4 200'F (93'C) Green 2eEF (141"C) Blue NOTES Ill Usind by underwriters Laboratories, Inc. (UL UsteR. 1 Appreved by Footorn Mutual fleseorsh Corporation IFM uppiovedl. (2) Listed by underwriters Laboratories, Inc. for use in 141 Approved by the City 01 New Vein under MEA 117-03-f. cerede IC-ui. Uotedl, TABLE A LABORATORY LISTINGS AND APPROVALS (Refer To The Design Criteria Section) Design Criteria UL and C-UL Listing Requirements The TYCO 16.8 K-factor, Model K17-231 )TY7151 & TY7251) Sprinklers may be installed in accordance with NFPA 13 standard sprinkler position and area/ density flow calculation requirements for light, ordinary, or extra hazard oc- cupancies with a minimum residual (flowing) pressure of 7 psi (0,5 bar) in wet or dry pipe sprinkler systems, or they may be installed in accordance with NFPA 13 standard sprinkler posi- tion and area/density flow calculation requirements for high piled storage oc- cupancies (solid piled, palletized, rack storage, bin boa, and shell storage in-cluding but not limited to Class I-tv and Group A plastics) with a minimum resid- ual (flowing) pressure 017 psi (0,5 bar) for wet or dry pipe systems. The following two examples are typical of the types of arrangements permit- ted by NFPA 13. For all combinations of lesser and greater building heights, lesser and greater storage heights, storage arrangements, commodity classifications, and lesser or greater re-quired design densities, refer to NFPA 13 for specifics. 1 Maximum Working Pressure 175 psi (12,1 bar) Physical Characteristics Frame ...................Bronze Pipe Thread Connection Button...................Bronze 3/4 inch NPT Sealing Assembly. ..ick...el N wITEFLOF'J...Beryllium Discharge Coefficient K = 16.8 GPM/psi'- Bulb (5 mm) ................Glass (241,9 LPM/bar1'u) . Compression Screw.........Brass Deflector..................Brass Page 1 of 4 FEBRUARY 2012 TFP332 TFP332 TFP332 Page 3of4 Page 4 of 4 3 - Sealing Assembly 6 Compression NOMINAL (62-Z 11, Temperature rating is indicated on deflector I WRENCH 3/4" FLAT NPT CROSS SECTION UPRIGHT PENDENT FIGURE I ULTRA K17, 155F (68C) & 200F (93C), UPRIGHT SPRINKLERS (TY7153) Operation The glass bulb contains s fluid that ex- pands when exposed to heat When the rated temperature Is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and flow water. Installation Iesarg Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontal, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm). The TYCO Model K17-231 Sprinklers must be installed in accordance with the following instructions. Step 1. With pipe thread sealant ap-plied to the pipe threads, hand tighten the Model K17-231 Sprinkler into the sprinkler fitting. Step 2. Using the W-Type 8 Sprin- kler Wrench (Ref. Fig. 2) applied to the sprinkler Wrench Flats (Ref. Fig. 1), tighten the Model K17-231 Sprinkler into the sprinkler fitting. CEM A teak tight 3/4 inch NPTsprinklerJoint should be obtained with a torque of 10 to 20 ft.lbs. (13,4 to 26,8 Alm). Higher levels of torque may distort the sprin- kler inlet with consequent leakage or impairment of the sprinkler Care and Maintenance The TYCO Ultra K17 Sprinklers must be maintained and serviced in accordance with the following instructions: y,Iestcg. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection systems must be obtained from the proper authorities and all personnel who maybe affected by this action must be notified. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaning the factory. Modi- fied sprinklers must be replaced. Sprin- klers that have been exposed to corro- sive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam-age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Nss FIGURE 2 W- TYPE 8 SPRINKLER WRENCH The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Association (for example, NFPA 25), In addition to the standards of any other authorities having jurisdiction. The installing con- tractor or sprinkler manufacturer should be contacted relative to any questions. Automatic sprinkler systems are recom- mended to be inspected, tested, and maintained by a qualified Inspection Service in accordance with local re- quirements and/or national codes. Limited Warranty Products manufactured by Tyco Fire Protection Products (TFPP) are war- ranted solely to the original Buyer for ten (10) years against defects in ma- terial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFPP. No warran-ty is given for products or components manufactured by companies not af- filiated by ownership with TFPP or for products and components which have been subject to misuse, improper in- stallation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protec- tion Association, and/or the standards of any other Authorities Having Juris- diction. Materials found by TFPP to be detective shall be either repaired or re-placed, at TFPP's sole option. TFPP neither assumes, nor authorizes any person to assume for it, any other ob-ligation in connection with the sate of products or parts of products. TFPP shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. In no event shall TFPP be liable, in con- tract, tort, strict liability or under any other legal theory, for incidental, in- direct, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFPP was informed about the possibility of such damages, and in no event shall TFPP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties, esoress or imolied, including warranties of mer- chantability and fitness for a oarticular oumose. This limited warranty sets forth the ex-clusive remedy for claims based on fail- ure of or detect In products, materials or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure When placing an order, indicate the foil product name. Please specify the Sprinkler Identification Number (SIN), quantity, and temperature rating. Refer to the Price Ust for complete listing of Part Numbers. Contact your local distributor for availability. Sprinkler Assemblies with NPT Thread Connections Specify: (specify SIN), 16.8 K-factor, Model K17-231,)specify temperature rating), (specify Pendent or Upright) Sprinkler, P/N (specify). Upright (SIN TY7151) 195"F (eeC) ..........P014 51-8e8-1-155 200'F (93'C) .........PON 51-888-1 -200 286F)141'C) ........ PS1451-efle-1-286 Pendent (SIN 1Y7251) 153/F (e3/C) ..........PaN 51-ee9-1-155 200'F (93'C) .........PSN 51-889-1-200 283/F )141'C) ........PSN 51-889-1-288 Sprinkler Wrench Specify: W-Type 8 Sprinkler Wrench, P/N 56-892-1-001. Copyright tOt 2005, 2012 Tyco Fire Protection Products. All rights reserved. TEFLON is trademark of The Dupont Corporation. tqc11 cw~ =0120 ikl3M FIRE SPRINKLER CORPORATION QUICK RESPONSE EXTENDED COVERAGE LIGHT HAZARD A UTOMA TIC SPRINKLERS MODEL GL8109 PENDENT QUICK RESPONSE EXTENDED COVERAGE LIGHT HAZARD AUTOMATIC SPRINKLERS MODEL GL8109 PENDENT cPPrIPIrA TIflt1I DESCRIPTION AND OPERATION The Globe Quick Response Model GL8109 Extended Coverage Pendent Sprinkler for Light Hazard occupan- cies is a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. While this Quick Response Sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard light hazard ex- tended coverage pendent sprinklers are specified; but offers the additional feature of greatly increased safety to life. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction, in accordance with their listings and in accor- QUICK RESPONSE dance with NFPA 13. EXTENDED COVERAGE The heart of Globe's GL Series sprinkler proven PENDENT actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the pre- scribed temperature the internal pressure within the am- pule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern. TECHNICAL DATA See reverse side for Approvals and Specifications. Temperature Rating - 135°F (57C), 155°F (68°C), 175°F (79°C) and 200°F (93°C). Water Working Pressure Rating - 175 psi (12 Bars). Factory tested hydrostatically to 500 psi (34 Bars). QUICK RESPONSE Maximum low temperature glass bulb rating is -67°F (-55°C). RECESSED Frame - bronze • Deflector - brass • Screw - brass EXTENDED COVERAGE Bulb seat - copper • Spring - nickel alloy • Seal - teflon PENDENT Bulb - glass with alcohol based solution, 3mm size. Escutcheon Assembly - steel SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING AVAILABLE BULB N.P.P.A. MAXIMUM CEILING CLASSIFICATION SPRINKLER TEMPERATURES COLOR TEMPERATURE ORDINARY 135°FI155°F 57°C/88°C ORANGE/RED 155°F 38°C INTERMEDIATE 175°F/200°P 79°C193'C I YELLOW/GREEN 150°F 66°C j 4077AIRPARKDRIVE, STANDISH, MICHIGAN 48658 989-8464583 • FAX989-846-9231 JULY2I5 A-41 BULLETIN GL81O9,REV.#5 I NOMINAL "K" FACTOR THREAD SIZE' LENGTH I FINISHES Factory Bronze ISahn Chrome' 8.1 (116 metric) 4" N FIT 3" (7.6) Bright Chrome White Pblyesterl IBlack Pblyester2 Leal Coded' NOTE METRIC CONVERSIONS ARE APPROXIMATE 'FINISHES AVAILABLE ON SPECIAL ORDER 'AVAILABLE AS cSLo LISTED CORROSION APPROVALS RESISTANT IM-/EN SPECIFIED ON ORDER SIN K STYLE 135°F 155°F 175°F 200°F CULUS MODEL FACTOR 57°C 88°C 79°C 93°C PENDENT GL8109 8.1 X x x x X U.L. LISTING DESIGN - USE REQUIREMENTS FOR LIGHT HAZARDS ONLY SIN STYLE TEMP. AREA OF MIN. PRESSURE FLOW IN GP.M. MODEL COVERAGE P.S.I. 135'F/57°C 16' x 16' 10.3 26 Standard 155°F/68°C GL8109 & 175°F/79°C 18' x18' 16.6 33 Recessed 200°F/83'C 135°F/57°C 20' E 20' 24.4 40 NOTE: DUE TO THE HIGH SPRAY PATTERN CREATED BY THIS SPRINKLER, THERE MUST BE A MINIMUM SPACING OF 8-0" BETWEEN SPRINKLERS TO ELIMINATE THE RISK OF COLD SOLDERING. ORDERING INFORMATION °' : SPECIFY / Quantity • Model Number Style REDUCE XETXiAEH Orifice • Temperature • Finishes desired Quantity - Wrenches - PIN 312366 cur Quantity - Recessed Wrenches - P/N 328401, Rev. D ° Quantity - Protective Caps - P/N 327109-CAP (Friction Fit Recessed) _____________ lIE MO. 7/8 MAX. GLOBEtm PRODUCT WARRANTY Globe agrees to repair or replace any of its own 1, MIN manufactured products found lobe defective is material or workmanship for a period of one year from date of CROSS SECTION shipment. For specific details of our warranty, please refer to og.6mm Price List Terms and Conditions of Sale (Our Price List). 4O77AIRPARKDRIVE, STANDISH, MICHIGAN 48658 989-846-4583 FAX989-846-9231 FIRE SPRINKLER CORPORATION 1-800-248-0278 wevw.g)obesprinkler.Com JULY2005 PRINTEDu S.A BULLETIN GL8109, REV. #5 QUICK RESPONSE A UTOMA TIC SPRINKLERS GL SERIES UPRIGHT. PENDENT FIRE SPRINKLER CORPORATION VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) DESCRIPTION AND OPERATION The Globe Quick Response GL Series Sprinklers are a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approxi- mately six times faster than ordinary sprinklers. While the Quick Response Sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard spray sprinklers are specified when allowed by the applicable standards. It offers the additional feature of greatly increased safety to life and is available in various styles, orifices, temperature ratings and finishes to meet many varying design QUICK RESPONSE requirements. Quick Response Sprinklers should be used advisedly UPRIGHT CONVENTIONAL and under the direction of approving authorities having jurisdiction. The heart of Globe's GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule ex- ceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern depend- ing upon the deflector style used. QUICK RESPONSE TECHNICAL DATA PENDENT VERTICAL 'See reverse side for Approvals and Specifications. SIDEWALL 'Temperature Ratings - 135°F (57°C), 155°F (68°C), 175°F (79°C), 200°F (93°C), 286°F (141°C) 'Water Working Pressure Rating -175 psi (12 Bars) 'Factory tested hydrostatically to 500 psi (34 Bars) Maximum low temperature glass bulb rating is -67°F (-55°C) 1W Frame - bronze • Deflector - brass • Screw - brass 'Bulb seat - copper • Spring - nickel alloy • Seal - teflon QUICK RESPONSE 'Bulb - glass with alcohol based solution, 3mm size HORIZONTAL SIDEWALL 'SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING I I AVAILABLE SPRINKLER I I N.F.P.A. MAXIMUM I CLASSIFICATION I I TEMPERATURES BULB COLOR I I I I CEILING TEMPERATURE ORDINARY 135°F/155°F 57°C/68°C II ORANGE/RED I 100F 38°C I INTERMEDIATE I 175°F/200°F 79°C/93°C YELLOW/GREEN I 150°F 66°C HIGH i41°C BLUE 225°F 107°C :1 4O77 AIR PAR K DRIVE, STAND ISH, MICHIGAN 46658 989-846-4583 • FAX989-846-9231 MAY 2011 A-20 BULLETIN GL5615, REV. #7 QUICK RESPONSE AUTOMATIC SPRINKLERS GL SERIES UPRIGHT. PENDENT. VERTICAL SIDEWALL HORIZONTAL SIDEWALL. CONVENTIONAL (OLD STYLE) SPECIFICATIONS NOMINAL °°K'° FACTOR THREAD SIZE LENGTH' I FINISHES 2.8 (39 metric) 1/2" NPT 2 1$" (5.7 cm) Factory Bronze 42 (59 metric) 1/2" NPT 2 1/4" (5.7 cm) I Bright Chrome I Satin Chrome ° I 5.6 (80 metric) 1/2" NPT 2 1/4 (5.7 cm) White Polyester ° 7.8 (111 metric) 1/2" NPT 2 1/4° (5.7 cm) IBlack Polyester 8.1 (116 metric) 3/4" NPT 27/16" (6.2 cm) Lead Coated ° NOTE: METRIC CONVERSIONS ARE APPROXIMATE. HORIZONTAL SIDEWALL IS 9/16°. ° FINISHESAVAILABLE ON SPEcIAL ORDER. AVAILABLE AS CULo LISTED CORROSION APPROVALS RESISTANT WHEN SPECIFIES ON ORDER. STYLE SIN K 135°F 155°F 175°F 200°F 286°F cuLW F.M. LPC CE NYC -008 MEd MODEL FACTOR 57°C 68°C 79°C 93°C 141°C IOI-92-E 0L2815 2.8 X It X X X X — It GL4215 4.2 X X X X It X - - - X UPRIGHT GL5615 5.6 It x X X It x x x It It GLS115 7.8° It X It X It X — - — It 0L8118 8.1 X It X X X X X X X It 01.2801 2.8 X X X X It X — — — It 0L4251 4.2 X X It X It X — — -. It PENDENT 0L5651 5.6 X X X X It X X x It It GL810I 7.8° X X It X It It X - - It GL8106 8.1 X I X X I X I X X I X I X X It VERTICAL 0L5632 5.6 It X It It It It X - - — SOEWALLI GL8133 8.1 X X X X X X - - - — GL2826 2.8 It It X It x It — — — It HORIZONTAL GL4226 4.2 X It It It x It — — — It SIOEWALLfl 0L5626 5.6 It X It It x X X - - It 0L8127 8.1 It X X X X X - - - — CONVENTIONAL 0L5624 5.6 x X It It x - — x x - (OLD STYLE) GL8125 8.1 It It X It x - - X x — 1/2" NPT VERTIcAL SIDEWALL SPRINKLER cUL. LISTED FOR LIGHT HAZARD ONLY. PENDENT VERTICAL SIDEWALL oULus LISTED FOR 6' MIld. SPACING. UPRIGHT VERTICAL SIDEWALL vUL. LISTED FOR 9* MIN. SPACING. HORIZONTAL SIDEWALL nULu LISTED FOR DEFLECTOR 4" TO 12° BELOW flPflPIt.J(4 INFORMATION THE CEILING, FM APPROVED 4° TO 6°. GLOBEIA PRODUCT WARRANTY Globe agrees to repair or replace any of Its own manufac- tured products found to be defective in material or workmanship for a period of one year from date of shipment. For Specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4563 FAX 989-846-9231 1-800-248-0278 www.globesprinkler.Com PRINTED U.S.A. BULLETIN GL5615, REV. #7 SPECIFY Quantity • Model Number • Style Orifice • Thread Sizes • Temperature "Finishes desired Quantity - Wrenches - P/N 325390 (1/2°); P/N 312366 (L.O.) a m6ms 93 M FIRE SPRINKLER CORPORATION MAY 2011 TFP5SO Page 2 of 8 tL,cQ Fire Suppression & Building Products Technical Services 800-381-9312 I +1-401-781-8220 www.tyco-fire.com Series DS-2 Dry-Type Sprinklers 11..21C Pendent Standard and Quick Response, Standard Coverage 1(5255 Standard Response 1Y5235 TY5255 Quick Response Standard Response with Flush Escutcheon TY5235 (Figure 2) Quick Response Temperature Bulb with Extended Escutcheon with Recessed Escutcheon Rating Color Code (Figure 4) (Figure 31 without Escutcheon (Figure 5) SPRINKLER FINISH Natural Brass Chromed I White Natural Brass I C hromed Whi I te Plate P olyester Po ( Plate 1peuter 130F l5Cl Orange 1,2, 3 1,2,3 155-F l68-Cl Red 175-F (79-C) Yellow 200'F (93-C) Green N/A 2eFFl141-C( Blue Notes Listed by Underwriters Laboratories, Inc. (maximum order length of 48 inches) Listed by Underwriters Laboratories for use in Canada (maximum order length of 48 inches) Approved by the City of New York under MEA 173-02-E TABLE A SERIES DS-2 STANDARD RESPONSE DRY-TYPE PEP/DENT SPRINKLERS - LABORATORY LISTINGS AND APPROVALS - General Description TYCO Series DS-2 Dry-Type Sprinklers, 11.2K Pendent, Standard (5 mm Bulb) and Quick Response (3 mm Bulb) and Standard Coverage, are decora- tive glass bulb automatic sprinklers typically used where: pendent sprinklers are required on dry pipe systems that are exposed to freezing temperatures; for example, sprinkler drops from unheated portions of buildings sprinklers and/or a portion of the connecting piping may be exposed to freezing temperatures; for example, sprinkler drops from wet systems into freezers rD)tt.I Series DS-2 Dry-Type Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the appli-cable standards of the National Fire Protection Association, in addition to the standards of any other Authorities Having Jurisdiction. Failure to do so may impair the performance of these devices. Owners are responsible for maintaining their tire protection system and devices in proper operating condition. The installing contractor or sprinkler manu- facturer should be contacted with any questions. IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 8 Series DS-2 Dry-Type Sprinklers must only be installed in fittings that meet the requirements of the Design Criteria section. Model/Sprinkler Identification Numbers (SINs) 1Y5255 - Standard Response 1Y5235 - Quick Response Technical Data Approvals UL and C-UL Listed NYC Approved under MEA 173-02-B Refer to Table A. Maximum Working Pressure 175 psi (12,1 bar) Inlet Thread Connections 1-inch NPT (Standard Order) ISO 7-Ri Discharge Coefficient Refer to Table B. Temperature Ratings Refer to Table A. Finishes Sprinkler: Natural Brass, Chrome Plated, White Polyester Escutcheon: White Coated or Chrome Plated, Brass Plated MAY 2011 Physical Characteristics Inlet.....................Copper Plug ....................Copper Yoke ..............Stainless Steel Casing ...............Galvanized Carbon Steel Insert ...................Bronze Bulb Seat ................Bronze Bulb ......................Glass Compression Screw .......Bronze Deflector.................Bronze Frame ...................Bronze Guide Tube ......... Stainless Steel Water Tube .........Stainless Steel Spring .............Stainless Steel Gasketed Spring Plate Seal .........Beryllium Nickel w/Tellon' Pin ...............Stainless Steel Button Spring .......Stainless Steel Escutcheon ..........Carbon Steel 'Dupont Beghtered Tienroi1r TFP53O PLUG Will-I INLET GASKETED SPRING PLATE SEAL '- PIN SPRING '" ''- YOKE INLET BAND 'N_ PLUG - SPRING WATER TUBE - - CASING GUIDE TUBE I_ INSERT BULB VENT ROLE SEAT FRAME 3L m COMPRESSION - , 2 SCREW ' DEFLECTOR FIGURE I SERIES DS-2 STANDARD RESPONSE DRY-TYPE PENDENT SPRINKLER - ASSEMBLY - Operation When TYCO Series DS-2 Dry-Type Sprinklers are in service, water is prevented from entering the assembly by the Plug with Gasketed Spring Plate Seal (Figure 1) in the Inlet of the Sprinkler. The glass bulb contains a told that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shutter the 'lass bulb, and the Bulb Seat is released. The compressed Spring is then able to expand and posh the Water Tube as well as the Guide Tube outward. This action simultaneously pulls inward on the Yoke, withdrawing the Plug with Gasketed Spring Plate Seal from the Inlet, allowing the sprinkler to activate and flow water. WRENCHING AREA ,,, PRINKL0R WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 6 W- TYPE 57 SPRINKLER WRENCH TFPS3O TFPS3O Page 3 of 8 Page 4o9 8 K-Factor K-Factor, LENGTH, GPM/psi"° Inches (mm) )LPM/barl'°) 2-1/2106-1/4 11.2 mm 10159mm) -(63 )161,3) 6-1/2 to 10-1/2 11.1 (165 min 10267 mm) (159,8) 10-3/4 to 14-3/4 11.0 )273 mm to 375 rem) )158,4) 151018-3/4 10.9 381 mm 10476 mom) 157,0) 191023 10.8 483 mm to 584 mm) (155,5) 23-1/41026-3/4 10.7 (591 mom 10670 mm) (154,1) 27-1/4 to 31-1/4 10.6 (692 mm 10704 rem) (152,6) 31-1/2 to 35-1/4 15.5 (800 mm to 895 mm) 151,2) 35-1/21039-1/2 10.4 (502 mm to 1003 mm) 149,8) 39-3/4 to 43-1/2 10.3 (1010 mm 101105mm) (148.3) 43-3/4 to 48 10.2 (1111 mm to 1219 mm) (140,9) Notes 6-Factor Length is determined as follows: 0luoh: Order Length from Figure 2 plus 1/2 Inch (12,7 mm) 90003005: Order Length from Figure 3 plus 1/4 Inch )6,3rem). 6o1s0404: Order 'Length from Figure 4 plus 3-1/4 Inch (82,6 mm) 6/ithoJL.6000l35000: Order Length from Figure minus 2.1/4 Inches (57,2 mm) TABLE B - DISCHARGE COEFFICIENTS - SPRINKLER FITTING FACE OF (REFER TO DESIGN SPRINKLER CRITERIA SECTION) FITTING ORDER LENGTHS: 3-5/9' DIA. 3 10 48' (92,1 mm) (76,2 to 1219,2 mm) IN 1/4' 6,4 tern) 2-314' DIA INCREMENTS 69,9 mm FACE OF CEILING 2.1/4±1/8* ESCUTCHEON (57,2±3.2 mm) WILL PERMIT I ±1/4 (6,4 mm) ADJUSTMENT FIGURE 2 SERIES DS-2 DRY-TYPE PENDENT WITH FLUSH ESCUTCHEON STANDARD RESPONSE (TY5255) OR QUICK RESPONSE (TY5235) -- SPRINKLER FITTING I FACE OF (REFER TO DESIGN SPRINKLER CRITERIA SECTION) FITTING ORDER LENGTHS: 3-1/2' to 48' 3-5/8 DIA. ) (92,1 ore) ''' l )88,9 to 1219,2 mm) IN 1/4'(6,4 mom) INCREMENTS FACE OF CEILING 1-5/8±1/8'° ESCUTCHEON (41,3±3,2 mm) WILL PERMIT 3/8"(9,5mm) _____ ADJUSTMENT FIGURE 3 SERIES DS-2 DRY-TYPE PENDENT WITH RECESSED ESCUTCHEON STANDARD RESPONSE (TY5255) DR QUICK RESPONSE (TY5235) 'SPRINKLER FITTING FACE OF (REFER TO DESIGN ORDER LENGTHS: SPRINKLER CRITERIA SECTION) I' 1045-1/4' FITTING 3-5/8' DIA. 25,4 to 1149,4mm) (92,1 mere) IN 1/4'(6,4 mm) INCREMENTS FACE OF CEILING FOR ORDER LENGTHS 3-1/4'(82,6 mm): VWILL SCUTCHEON 4-7/8*1/8' (123,8*3,2 mm) ILL PERMIT 0N 6/8' (15,9 mm) DJUSTMENT FOR ORDER LENGThS>3-1/4'(82.6 mm): 5-5/8*1/8' (142.9*3.2 mm)* SCUTCHEON PERMIT l-3/& (34,9 mm) DJUSTMENT FIGURE 4 SERIES DS-2 DRY-TYPE PENDENT WITH EXTENDED ESCUTCHEON STANDARD RESPONSE (TY5255) OR QUICK RESPONSE (TY5235) C I SPRINKLER FITTING FACE OF (REFER TO DESIGN SPRINKLER CRITERIA SECTION) FITTING ORDER LENGTHS: 5 to 48 (127,0 to 1219,2 mm) IN 1/4' 6,4 mm) INCREMENTS MINIMUM 2-1/4 DEFLECTOR TO CEILING FIGURE 5 SERIES DS-2 DRY-TYPE PENDENT WITHOUT ESCUTCHEON STANDARD RESPONSE (1Y5255) OR QUICK RESPONSE (TY5235) lFP530 TFPB3O Page 5 of 8 Page 6 of 8 Ambient Temperature Exposed to Discharge End of Sprinkler Temperatures for Heated Area' 40F (4C) 50F (1ETC) 60F (16CC) Minimum Exposed Barrel Length Inches (mm)2 40'F (4C( 0 0 0 30-F (-1CC) 0 5 0 20-F (-70) 4 (105) 5 0 11FF (-12C) 8(200) 1(25) 0 1SF (-leC) 12(305) 3(75) 0 -11SF (-23-C) 14(355) 4(100) 1(25) -21SF (-21FC) 14(355) 6(150) 3(75) -31SF (-34C) 15(405) 1 8)200) 4(100) -41SF(-40-C) 18(455) 8(200) 4(100) -51FF (-41SC) 20(510) 10(255) 6)150) -61FF (-51C) 20(510) 10(255) 6)150) Notes For protected area temperatures that occur between values listed above, use the next cooler temperature. These lengths are inclusive of wind velocities up to 30 mph (15,6 kph(. TABLE C EXPOSED SPRINKLER BARRELS IN WET PIPE SYSTEMS - MINIMUM RECOMMENDED LENGTHS - Design Criteria TYCO Series DS-2 Dry-Type Sprinklers are intended for use in fire sprinkler systems designed in accordance with the standard coverage installation roles recognized by the applicable Listing agency; for example, UL Listing is based on NFPA 13 requirements. Sprinkler Fittings Install 1-Inch NPT Series DS-2 Dry-Type Sprinklers in the 1-inch NPT outlet or run of the following fittings: malleable or ductile iron threaded tee fittings that meet the dimen- sional requirements of ANSI P16.3 (Class 150) cast iron threaded tee fittings that meet the dimensional requirements of ANSI 816.4 (Class 125). Do not install Series DS-2 Dry-Type Sprinklers into elbow fittings. The Inlet of the sprinkler can contact the interior of the elbow. The unused outlet of the threaded feels plugged as shown in Figure 9. You can also install Series DS-2 Dry-Type Sprinklers in the 1-inch NPT outlet of a GRINNELL Figure 730 Mechanical Tee. However, the use of the Figure 730 lee for this arrangement is limited to wet pipe systems. The configuration shown in Figure 8 is only applicable for wet pipe systems where the sprinkler titling and water-filled pipe above the sprinkler fitting are not subject to freezing and where the length of the Dry-Type Sprinkler has the minimum exposure length depicted in Figure 10. Refer to the Exposure Length section. For wet pipe system installations of 1-inch NPT Series DS-2 Dry-Type Sprinklers connected to CPVC piping, use only the following TYCO CPVC fittings: 1" x 1" NPT Female Adapter (P/N 80145) 1 s 1" x 1" NPT Sprinkler Head Adapter Tee (P/N 80249). For dry pipe system installations, use only the side outlet of maximum 2-1/2- inch reducing tee when locating Series 05-2 Dry-Type Sprinklers directly below the branch line. Otherwise, use the configuration shown in Figure 5 to assure complete water drainage from above Series 05-2 Dry-Type Sprinklers and the branch line. Failure to do so may result in pipe freezing and water damage. II.)I1W Do not install Series DS-2 Dry-Type Sprinkler into any other type fitting without first consulting the Technical Services Department. Failure to use the appropriate fitting may result in one of the following: Failure of the sprinkler to operate prop- erly due to formation of ice over the Inlet Plug or binding of the Inlet Plug. Insufficient engagement of the Inlet pipe-threads with consequent leakage. Drainage In accordance with the minimum requirements of the National Fire Protection Association for dry pipe sprinkler systems, branch, cross, and feed-main piping connected to Dry Sprinklers and subject to freezing temperatures must be pitched for proper drainage. Exposure Length When using Dry Sprinklers in wet pipe sprinkler systems to protect areas subject to freezing temperatures, use Table C to determine a sprinkler's appropriate exposed barrel length to prevent wafer from freezing in the connecting pipes due to conduction. The exposed barrel length measure-ment must be taken from the face of the sprinkler fitting to the surface of the structure or insulation that Is exposed to the heated area. Refer to Figure 10 for an example. TO WET SIDE SYSTEM I OUTLET PLUGGED 'RINKLER SP DSB-2 FITTING BOOT SEE DESIGN CRITERIA SECTIONI FIGURE 8 SPRINKLER FITTING - HEATED AREA - RUN OUTLET PLUGGED TO DRY SPRINKLER FInING SYSTEM ISEE DESIGN CRITERIA SECTION) DSB-2 BOOT FIGURE 9 SPRINKLER FITTING - UNHEATED AREA - For protected area temperatures between those given above, the minimum recommended length from the face of the fitting to the outside of the protected area may be determined by interpolating between the indicated values. Clearance Space In accordance with Section 8.4.9.2 of the 2010 edition of NFPA 13, when connecting an area subject to freezing and an area containing a wet pipe sprinkler system, the clearance space around the sprinkler barrel of Dry-Type FACE OF SPRINKLER - - FITTING EXPOSURE LENGTH (SEE DESIGN CRITERIA DSB-2 SECTION) BOOT U t FIGURE 10 - EXPOSURE LENGTH - STRAP TIES (ENDS ON OPPOSING SIDES OF BOOT) DSB-2 BOOT ADHESIVE 1~7-' 2-3/4 DIA. RE (eg, CLEARANCEHO INSULATED FREEZER ____ SHOWN WITH PLUSH ESCUTCHEON FIGURE II MODEL DSB-2 DRY SPRINKLER BOOT WITH SERIES DS-2 DRY-TYPE PENDENT SPRINKLER Sprinklers must be sealed. Due to temperature differences between two areas, the potential for the formation of condensation in the sprinkler and subsequent ice build-up is increased. If this condensation is not controlled, ice build-up can occur that might damage the dry-type sprinkler and/or prevent proper operation in a fire situation. Use of the Model OSB-2 Dry Sprinkler Boot, described in technical data sheet TFP591 and shown in Figure 11, can provide the recommended seal. Installation Series DS-2 Dry-Type Sprinklers must be installed in accordance with the following instructions. CEM Series D$-2 Dry-Type Sprinklers must only be installed in fittings that meet the requirements of the Design Criteria section. Refer to the Design Criteria section for other important require- ments regarding piping design and sealing of the clearance space around the Sprinkler Casing. With reference to Figure Z do not grasp the sprinkler by the deflector. Failure to follow this instruction may impair performance of the device. Do not install any bulb-type sprinkler if the bulb is cracked or there is loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135F (57C) rating to 1/8 inch (3,2 mm) for the 361SF (1 82'C)rating. Obtain a leak-tight 1-inch NPT sprinkler joint by applying a minimum-to-maximum torque of 20 to 30 ft. lbs. (26,8 to 40,2 NIT). Higher levels of torque may distort the sprinkler Inlet with consequent leakage or Impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in an Escutcheon Plate by under or over-tightening the Sprinkler. Re-adjust the position of the sprinkler fitting to suit. Install pendant sprinklers only is the pendent position. The deflector of pendent sprinkler must be parallel to the ceiling. With a non-hardening pipe-thread sealant such as Teflon' applied to the Inlet threads, hand-tighten the sprinkler into the sprinkler fitting. Do not grasp the sprinkler by the deflector (Figure 7). Wrench-tighten the sprinkler using either: a pipe wrench on the inlet Band or the Casing (Figure 1). the W-Type 17 Sprinkler Wrench on the Wrench Flat (Figure 2). Apply the Wrench Recess of the W-Type 17 Sprinkler Wrench to the Wrench Flat. 'ouPcrt Registered Tradenrurir P/N' 61 - XXX - X - XXX ORDER I LENGTH 12i MODEL/SIN SPRINKLER E5CCHEON 055 5.5ar FINISH FINISH(i) tO Standard Response Pendent 1Y5255 1 NATURAL BRASS WHITE 082 e.25" with Flash Escutcheon (Figure 21 11 Standard Response Pendent 5255 4 WHITE POLYESTER WHITE 185 18.00 with Recessed Escutcheon IPlosre 31 12 standard Response Pendent TY5255 9 CHROME PLATED CHROME le? lens' with Extended escutcheon IFiture 41 - 13 Standard Respoyse Pendant 1Y5255 0 CHROME PLATED WHITE 372 37.25 without Flush Escutcheon fFlgsre 5 NATURAL BRASS BRASS PLATED eus xe.00 TEMPERATURE r1 RATING 131 32 S l35FlsPCl --_-_- msu'Fiewcl t75'F9Ci Notes Use Prefix "I" for ISO 7-R1 Connection; for example, l-61-101-1-180. 200'F183'Cl Escutcheon Finish applies to sprinklers with escutcheons. 29E.F 1141.01 Dry-Type Sprinklers are furnished based upon 'Order Length" as measured per Figures 2 through 5, as applicable, and for each individual sprinkler where it is to be installed. After the measurement is takes, round it to the nearest 1/4 inch increment. 286'F (141'C( temperature rating applies to non-recessed sprinkler assemblies. TABLED SERIES DS-2 STANDARD AND QUICK RESPONSE, STANDARD COVERAGE, DRY-TYPE SPRINKLERS - PART NUMBER SELECTION - 30 Quick Response Pendent 1Y5235 with Flush Escutcheon (Figure 21 3 QuIck Response Pendent ryssas wIth Recessed Escutcheon (Figure 31 Quick Response Pendent 1Y523s with Extended Escutcheon (Figure 4l Quick Response Pendent TY5235 without Flush Escutcheon (Fig.. 5)_- TFP53O TFP53O Page 7 of 8 Page 8 of 8 Note: If sprinkler removal becomes necessary, remove the sprinkler using the same wrenching method noted above. Sprinkler removal is easier when a non-hardening sealant was used and torque guide- lines were followed. After removal, inspect the sprinkler for damage. 4. After installing the ceiling and applying a ceiling finish, slide on the outer piece of the Escutcheon until it comes in contact with the ceiling. Do not lift the ceiling panel out of its normal position. When using the Deep Escutcheon, hold the outer piece in contact with the mounting surface (ceiling or wall). Then rotate the inner piece approximately 1/4 turn with respect to the outer piece, to hold the Deep Escutcheon firmly together. Care and Maintenance TYCO Series DS-2 Dry-Type Sprinklers must be maintained and serviced in accordance with the following instructions. Lq.Rfg. Before closing a tire protection system main control valve for maintenance work on the fire protection System that it controls, obtain permission to shut down the affected lire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a Era situation. A Vent Hole is provided in the Bulb Seat (Figure 1) to indicate if the Dry Sprinkler is remaining dry. Evidence of leakage from the Vent Hole indicates potential leakage past the Inlet seal and the need to remove the sprinkler to determine the cause of leakage; for example, an improper installation or an ice plug. Close the fire protection system control valve and drain the system before removing the sprinkler. Exercise care to avoid damage before, during, and after installation. Never paint, plate, coat, or otherwise alter automatic sprinklers after they leave the factory. Never repaint factory-painted Cover Plates. When necessary, replace cover plates with factory-painted units. Non-factory applied paint can adversely delay or prevent sprinkler operation in the event of a fire. Replace sprinklers that: were damaged by dropping, striking, wrench twisting, wrench slippage, or the like. were modified or over-heated. have cracked bulbs or have lost liquid from the bulbs. Refer to the Installation Section In this data sheet. are leaking or exhibiting visible signs of corrosion. Responsibility lies with owners for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Association (for esample, NFPA 25), in addition to the standards of any other Authorities Having Jurisdiction. The installing contractor or sprinkler manufacturer should be contacted relative to any questions. Automatic sprinkler systems are recom- mended to be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. Limited Warranty Products manufactured by Tyco Fire Suppression and Building Products )TFSBP) are warranted solely to the original Buyer against defects in material and workmanship when paid for and properly installed and main-tained under normal use and service. This warranty will expire twelve (12) months from installation or eighteen (18) months from delivery, whichever occurs first. No warranty Is given for products or components manufac-tured by companies not affiliated by ownership with TFSBP or for products and components which have been subject to misuse, Improper instal- lation, corrosion, or which have not been Installed, maintained, modified or repaired in accordance with appli-cable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFSBP to be defective shall be either repaired or replaced, at TFSBP's sole option. TFSBP neither assumes, nor authorizes any person to assume for It, any other obligation in connection with the sale of products or parts of products. TFSBP shall not be respon- sIble for sprinkler system design errors or Inaccurate or Incomplete infor- mation supplied by Buyer or Buyer's representatives. In no event shall TFSBP be liable, In contract, tort, strict liability or under any other legal theory, for incidental, Indirect, special or consequential damages, including but not limited to labor charges, regardless of whether TFSBP was Informed about the possi-bility of such damages, and in no event shall TFSBP's liability exceed an amount equal to the sales price. The foreooino warranty is made is lieu merchantability and fitness for a partic-ular purpose. This limited warranty sets forth the exclusive remedy for claims based on failure of or defect in products, materials or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full extent permitted by law. The invalidity, in whole or pert, of any portion of this warranty will not affect the remainder. Ordering Procedure Contact your local distributor for avail-ability. When placing an order, indicate the full product name, including description and Part Number (P/N). Dry Sprinklers When ordering 11.2 1K-Factor Series DS-2 Dry-Type Sprinklers, specify the following information: Model/SIN Standard Response (TY5255( or Quick Response (TY5235(, Standard Coverage, Dry-Type Pendant Sprinkler Order Length Dry-Type Sprinklers are furnished based upon Order Length as measured from the face of the wall to the face of the sprinkler fitting (Figure 2 through 5). After the measurement is taken, round it to the nearest 1/4 inch increment. Inlet Connectionss 1-inch NPTor ISO 7-RI Temperature Rating Sprinkler Finish Escutcheon Type Part Number from Table D Sprinkler Wrench Specify W-Type 17 Sprinkler Wrench, P/N 56-010-4-118. Sprinkler Boot Specify Model DSB-2 Dry Sprinkler Boot, P/N 63-000-0-002. This Part Number includes one Boot, two Strap Ties, and 1/3 Dc. of Adhesive (quantity of adhesive is sufficient for installing one Boot). Copyright 0 2007, 2011 Tyco Fire Suppression & Building Products. All rights reserved. MATERIAL -LIST PART: MATERIAL: HANDLE. . SIDES STEM BALL -RODIEASS ,C.PREOla SoDy'. SIGNIQLASS BROW ww0 VALVE SEAT IUPREGNAI1DISFLON INDICATOR PLAID SIDES HANDLE LOCK .$PRRIGSIDEL MODEL 1000 2TESTANDRAIN 3/4" 1" 11/4" 1 1/2' 2" - U The AGF Manufacturing Inc. Model 1000 TESTANDRAIN Provides Both The Test Function And The Express Drain Function For A Wet Fire Sprinkler System. ü The Model 1000 Complies With All Requirements Of NFPA-13, NFPA-13R, And NFPA-13D. U The Model 1000 TESTANDRAIN Is A Single Handle Ball Valve That Is Light Weight And Compact, Includes A Tamper Resistant Test Orifice, Integral Tamper Resistant Sight Glasses, And Is 300 PSI Rated. ) Available In A Full Range Of Sizes From 3/4' To 2 NPT & BS PT. With All Specifiable Orifice Sizes 3/s", 7/1?, 17/' Sle, (ELO). 3/4' (ESFR) and K.25. U The Orifice Size Is Noted On The Indicator Plate And The Valve Is Tapped For A Pressure Gauge. U The Standard Model 1000 TESTANDRAIN Valve Includes A Pressure Gauge Port Topping And Can Be Ordered With A Relief Valve As A Model 1011 Or lOUT U Locking Kit Available Which Provides Superior Vandal Resistance And Prevents Unintentional Alarm Activation. Our New G' visit in on the Internet Cd F-A MODEL 1000 300 PSI TESTAN DRAIN.. 3/4" 1" 11/4" 11/2' 2" PLAN VIEW FRONT VIEWIVER11CAL INSTALLAl1ON A I MOM BRANCH GAUGE INLEF PROVIDED TODRAIN SMEEI EL FRONT ViEW/HORIZONTAL INSTALLATION ORIFICE SIZE AVAILABLE — 3/V. 7/I6', 1/2'. 17/3( Ito/v). ESFR(3/4')' and K.25 'Available on 11/? to 2'she uriS, only. DIMENSIONS - INCHES SIZE A B 1 C 0 E F G I H 5 '1,4' 1n 1'!? V.5&Unv7 2 31,e 35/5' 93.557w, 3 5/a'. i&357n 1 i3i4' *5.593.99 4'/ia' 717.15593. 6 ala" 143.493199 In -- 5 '/i? .1219931 1 ½' 37*59931 2 3//' ItM*Vn 35/4' .9123799 3 5/? 15.31799 1,13/i 4' 15.593.9, 4 5/,( 117.193.9,, 6 ala' 162.49317n I ip. 5 li? I3L91w,. 1 fllj4' *293re7 2'/ia' 65.5931,, 4 Ile I913S.vn 3 5/i( flS*vwn 1 15//' 13.59,9,. 59/49 - 14159999 5 il4' I laTe, i i2 n 67li? talL,,, ui 1 , 15.593vn 3 lI' 11.5931w .5'!,? 199939. 37/sri 0.1*,.,, 2'!,' - 66.971,6,. 21643n9,1 8'!? ln.gbl,n 2' .1913*179 1 6 "is 1 rs/? ISialun 'Li' I 61.5*.,,, '1,? 199.9, 3 " 1 WiLl., 2% .66.9Th,, 8 "4' 216439.4 10 55540,,, OR PIPE TO DRAIN RIGHT HAND/STRAIGHT INSTALLATION APPROVALS: O UL and ULC listed 0 FM Approved except 3/4' Cl NYC-BSA NO. 720-87-SM Cl CA. State Fire Marshall ASSE® Listed 1048 (Sizes 2 1/2" thru 12") CSA® Certified B64.5 (Sizes 2 1/2" thru 8') AWWA Compliant C510 (Sizes 2 1/2" thru 12") UL® Classified (Sizes 2 1/2' thru 12') C-UL® Classified (Sizes 2 1/2' thru 12") FM® Approved (Sizes 2 1/2" thru 10") NYC MEA 147-99-M Vol 4 (2-1/2 - 10) Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California (Sizes 2 1/2" thru 12") MATERIALS Main valve body Ductile Iron ASTM A 536 Grade 4 Access covers Ductile Iron ASTM A 536 Grade 4 Coatings FDA Approved fusion epoxy finish Internals Stainless steel, 300 Series NORYLTM, NSF Listed Fasteners Stainless Steel, 300 Series Elastomers EPDM (FDA approved) Buna Nitrile (FDA approved) Polymers NORYLTM, NSF Listed Springs Stainless Steel, 300 Series -B - LH8 SPECIFICATION SUBMITTAL SHEET APPLICATION Designed for installation on potable water connections in fire sprinkler systems to protect against both backsiphonage and backpressure of polluted water into the potable water supply. Model 350DA shall provide protection where a potential health hazard does not exist. Incorporates metered by-pass to detect leaks and unauthorized water use. STANDARDS COMPLIANCE (Sizes 2 112"-10" Horiz. & Vert.) FEATURES (12" Horizontal Only) Sizes: U 2 1/2" U 3" U 4" U 6" U 8" U 10" U 12" Maximum working water pressure 175 PSI Maximum working water temperature 140°F Hydrostatic test pressure 350 PSI End connections (Grooved for steel) AWWA C606 (Flanged) ANSI 1316.1 Class 125 OPTIONS (suffixes can be combined) U - with OS & V gate valves (standard) U L - less shut-off valves (flanged body connections) U LM - less water meter U - with remote reading meter U - with gpm meter (standard) U CFM - with cu ft/min meter U G - with groove end gate valves U FG - with flanged inlet gate connection and grooved outlet gate connection U P1 - with Post Indicator Gate Valve (3-10') ACCESSORIES U Repair kit (rubber only) U Thermal expansion tank (Model XT) U OS & Y Gate valve tamper switch (OSY-40) U Test Cock Lock (Model TCL24) DIMENSIONS & WEIGHTS (do not include pkg.) MODEL 350DAG SHOWN ABOVE Attention: Model 350DA (flange body) and Model 350ADA (grooved body) have different lay lengths. MODEL DIMENSION _(approximate) WEIGHT 350DA SIZE in. mm A in. mm B LESS GATE VALVES in. I mm C in. I mm 0 in. I mm E ,-, PEN in. I mm E OS&Y CLOSED in. mm F in. mm WITHOUT GATES VALVES lbs. kg WITH OS&Y GATE VALVES lbs. I kg 2 1/2 65 31 787 157/8 403 33/41 95 9 229 163/8 416 137/8 352 31/2 89 68 30.9 178 80.8 3 80 32 813 157/8 403 33/41 95 9 229 187/8 479 155/8 397 31/2 89 1 68 30.9 198 90 4 100 375/8 956 191/2 495 41/2 114 9 229 223/4 578 1 181/4 464 6 152 106 48 296 134.4 6 150 443/4 1137 231/2 597 51/2 140 101/2 267 301/8 765 233/4 603 7 178 180 81.7 480 217.9 8 200 603/4 1543 373/4 959 10 254 12 305 1 373/4 531/81 959 291/4 1 743 81/2 216 374 170 850 385.9 10 250 633/4 1619 373/4 959 10 254 12 305 453/4 1162 353/8 899 81/2 216 404 183 1222 554.8 12 300 661/4 1683 38 965 10 254 12 305 1349..40 5/8 1032 87/8 226 463 210 1623 736.2 Page 1 of 2 WILKINS a Zurn Company, 1747 Commerce Way, Paso Robles, CA 93446 Phone: 805/238-7100 Fax:805/238-5766 In Canada: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 1L2 Phone:905/405-8272 Fax:905/405-1292 Product Support Help Line: 1-877-BACKFLOW (1-877-222-5356) • Website; http://www.zurn.com 0 0.0 PROIEOI1VE VERTICAL INSTALLATION ii) FLOW CHARACTERISTICS MODEL 350DA 21/2", 3" & 4" (STANDARD & METRIC) FLOW RATES (us) 0.0 12.6 25.2 37.9 200 400 600 FLOW RATES (GPM) MODEL 350DA 6" & 8" (STANDARD & METRIC) FLOW RATES Q/s) 31.5 63.1 946 126.2 - 0 500 1000 FLOW RATES (GPM) 1600 MODEL 350DA 10" & 12" (STANDARD & METRIC) FLOW RATES (us) 0.0 31.5 63.1 94.6 126.2 157.7 189.3 0 500 1000 1500 2000 2500 300C FLOW RATES (GPM) c Rated Flow (Established by approval agencies) 50.5 103 En U) 0 69 —j w—. 0. Cl) 34(l) W 0 0 800 157.7 103 69 . —l CL 34 ZJ —I D. -I 0 2500 283.9 103 69 _. —1 uj —I of El j0 0 4500 -- - p — — --- g1 2000 220.8 252.4 3500 4000 TYPICAL INSTALLATION Local codes shall govern installation requirements. Unless other- wise specified, the assembly shall be mounted at a minimum of 12" (305mm) and a maximum of 30" (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. Capacity thru Schedule 40 Pipe (GPM) Pipe size 5 ft/sec 7.5 ft/sec 10 ft/sec 15 ft/sec 2 1/2" 75 112 149 224 115 173 230 346 198 298 397 595 6" 450 675 900 1351 8" 780 1169 1559 2339 10" 1229 1843 2458 3687 12" 1763 2644 3525 5288 OUTDOOR INSTALLATION SPECIFICATIONS The Double Check Detector Backflow Prevention Assembly shall beASSE® Listed 1048, and supplied with full port gate valves. The main body and access cover shall be epoxy coated ductile iron (ASTM A 536 Grade 4), the seat ring and check valve shall be NorylTM (NSF Listed), the stem shall be stainless steel (ASTM A 276) and the seat disc elastomers shall be EPDM. The first and second check valves shall be accessible for maintenance without removing the device from the line. The Double Check Detector Backflow Prevention Assembly shall be a WILKINS Model 350DA. WILKINS a Zurn company, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805/238-7100 Fax:805/238-5766 In Canada: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 1L2 Phone:905/405-8272 Fax:905/405-1292 Product Support Help Line: 1-877-BACKFLOW(1-877-222-5356) • Website: http://www.zurn.com Page 2 of 2