HomeMy WebLinkAbout2525 EL CAMINO REAL; 208; FPC2017-0223; Permit(7city Of Carlsbad Print Date: 10/24/2022 Permit No: FPC2017-0223 Job Address: 2525 EL CAMINO REAL, # 208, CARLSBAD, CA 92008 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 1563020900 Track #: Applied: 08/08/2017 Valuation: $888,943.90 Lot #: Issued: 08/29/2017 Occupancy Group: Project #: Finaled Close Out: 04/16/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check #: INSPECTOR: Fieri, Dominic Plan Check #: Wong, Cindy Project Title: Description: YARD HOUSE -SPRINKLER TI >100 HEADS (96) Applicant: FPContractor: MARCUS ENGLISH JOHNSON CONTROLS FIRE PROTECTION LP 3568 RUFFIN RD P0 BOX 3042 SAN DIEGO, CA 92123-2597 BOCA RATON, FL 33431-0942 (858) 633-9125 (561) 341-7780 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $536.00 Total Fees: $536.00 Total Payments To Date: $536.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov tgy(_7.,70 Fire Protection Products Worldwide J Contacts www.tyco-fire.com Series RFII - 56 K-factor "Royal Flush II" Concealed Pendent Sprinklers Quick & Standard Response, Standard Coverage General Description The TYCO Series RFII 5.6 K-factor, "Royal Flush II" Concealed Pendent Sprinklers Quick Response (3-mm bulb) and Standard Response (5-mm bulb), are decorative sprinklers fea- turing a flat cover plate designed to conceal the sprinkler. These sprinklers are optimal for architecturally sensi- tive areas such as hotel lobbies, office buildings, churches, and restaurants. Each sprinkler includes a Cover Plate! Retainer Assembly and a Sprinkler! Support Cup Assembly. The separa- ble, two-piece assembly design pro- vides the following benefits: Allows installation of the sprinklers and pressure testing of the fire pro- tection system prior to installation of a suspended ceiling or application of the finish coating to a fixed ceiling. Permits the removal of suspended ceiling panels for access to building service equipment without having to first shut down the fire protection system and remove sprinklers. Provides for 1/2 inch (12,7 mm) of vertical adjustment to allow a measure of flexibility in determining the length of fixed piping to cut for the sprinkler drops. The Series RFll Sprinklers are shipped with a Disposable Protective Cap. The Protective Cap is temporarily removed during installation and replaced to help protect the sprinkler during ceiling installation or finish. The tip of the Pro- tective Cap can be used to mark the center of the ceiling hole into plaster board or ceiling tiles by gently pushing the ceiling product against the Pro- tective Cap. When ceiling installa- tion is complete, the Protective Cap is removed and the Cover Plate/Retainer Assembly is installed. As an option, the Series RFll Standard Response (5-mm bulb) "Royal Flush II" Concealed Pendent Sprinklers can be fitted with a silicone Air and Dust Seal. (Refer to Figure 5.) The Air and Dust Seal is intended for sensitive areas where it is desirable to prevent air and dust from the area above the ceiling to pass through the cover plate. N!L.1tL.1 The Series RFII Concealed Pendent Sprinklers described herein must be installed and maintained in compliance with this document and with the appli- cable standards of the National Fire Protection Association, in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY3531 - 3 mm bulb 1Y3551 - 5 mm bulb Technical Data Sprinkler Approvals Approvals apply only to the service conditions indicated in the Design Criteria section. TY3531 (3 mm Bulb) is UL Listed, C-UL Listed and NYC Approved (MEA 353-01-E) as Quick Response. TY3531 (3 mm Bulb) is VdS Approved (Certificate No. G4090007). TY3531 (3 mm Bulb) is FM and LPCB Approved (Ref. No. 094a/10) as Standard Response. Note: FM and LPCB do not approve concealed sprinklers for quick response. TY3551 (5 mm Bulb) is UL Listed, C-UL Listed, FM Approved, LPCB Approved (Ref. No. 094a!9), and NYC Approved (MEA 353-01-E) as Standard Response. Approvals for Air and Dust Seal UL and C-UL Listed for use with the RFll Standard Response Concealed Sprinkler (TY3551) Maximum Working Pressure Maximum 250 psi (17,3 bar) by UL, C-UL, and NYC Maximum 175 psi (12,1 bar) by FM, VdS, and LPCB Temperature Rating 155°F (68°C) Sprinkler with 139°F (59°C) Plate 200°F (93°C) Sprinkler with 165°F (74°C) Plate Discharge Coefficient K= 5.6 GPM/psi112 (80,6 LPM/bar"2) TFPI8I Always r€ Sheet TFP WARNING FPC20I with respe 7-0223 lation of sp ponents. installation a sprinkle 2525 EL CAMINO REAL nents and to operate it to operai UNIT208 FILE Copy Page 1 ol SPRINKLER/SUPPORT CUP ASSEMBLY THREAD INTO fl RETAINER SUPPORT fi WITH THREAD CUP UNTIL 0 _- DIMPLES MOUNTING SURFACE IS EJECTION FLUSH WITH SPRING CEILING / SOLDER ' '-_ COVER TABS (3) COVER PLATE/RETAINER PLATE ASSEMBLY FIGURE 1 MODEL RFII CONCEALED SPRINKLER ASSEMBLY GUIDE PINS (2) DEFLECTOR -------------- 1/2' NPT FRAME SUPPOR CUP Will ROLL FORI THREADt EALING SEMBLY CAP BULB PRESSION CREW :LECTOR ROPPED POSITION) TFPI8I Page 2 of 4 Adjustment 1/2 inch (12,7 mm) Finishes See the Ordering Procedure section. Physical Characteristics Frame ............................Bronze Support Cup ............Chrome Plated Steel Guide Pins..................Stainless Steel Deflector ..........................Bronze Compression Screw ..................Brass Bulb. . ............................. Glass Cap .....................Bronze or Copper Sealing Assembly. . Beryllium Nickel w/TEFLON Cover Plate .........................Brass Retainer............................Brass Ejection Spring ..............Stainless Steel Design Criteria The TYCO Series RFII 5.6 K-factor, "Royal Flush II" Concealed Pendent Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency; for example, UL Listing is based on NFPA 13 and VdS Approval is based on the CEA 4001. For more information on LPCB and VdS Approvals, contact Tyco Fire Protection Products at the following office: Enschede, Netherlands Telephone: 31-53-428-4444 Fax: 31-53-428-3377 The Series RFll Concealed Pendent Sprinklers are only listed and approved with the Series RFII Concealed Cover Plates having a factory applied finish. L'1ILI Do not use the Series RFII in applica- tions where the air pressure above the ceiling is greater than that below. Down drafts through the Sprinkler/Support Cup Assembly can delay sprinkler operation in a fire situation. Operation When exposed to heat from a fire, the Cover Plate, normally soldered to the Retainer at three points, falls away to expose the Sprinkler/Support Cup Assembly. The Deflector - supported by the Guide Pins - then drops down to its operational position. The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, activating the sprinkler and allowing water to flow. Installation The TYCO Series RFII 5.6 K-factor, "Royal Flush II" Concealed Pendent Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 155°F (68°C) and 3/32 inch (2,4 mm) for the 200°F (93°C) tem- perature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a minimum to maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Sprinkler by under- or over-tightening the Sprin- kler/Support Cup Assembly. Re-adjust the position of the sprinkler fitting to suit. Step 1. Install the sprinkler only in the pendent position with the center-line of the sprinkler perpendicular to the mounting surface. Step 2. Remove the Protective Cap. Step 3. With pipe thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 4. Wrench-tighten the sprinkler using only the RFII Sprinkler Wrench. (Refer to Figure 3.) Apply the RFII Sprinkler Wrench to the Sprinkler as shown in Figure 3. FACE OF CLEARANCE HOLE SPRINKLER DIAMETER FITTING DIMENSION SPRINKLER SUPPORT CUP ASSEMBLY 1/2 (12,7 mm) L THREADED D ADJUSTMENT FACE OF CEILING, I RETAINING RING MOUNTING SURFACE V 3/16 to 11/16 MANUFACTURER DEFLECTOR COVER PLATE (4,8 to 17,5 mm) PRESET GAP IN DROPPED RETAINER REFERENCE 3/32 (2,4 mm) POSITION ASSEMBLY COVER PLATE COVER PLATE PROFILE DEPTH DIAMETER DIMENSION B DIMENSION A 3-1/4 inches (82,6 mm) C: 2-3/8 to 2-5/8 inches (60,3 to 66,7 mm) 3/16 inches (4,8 mm) D: 1-3/4 to 2-1/4 inches (44,5 to 57,2 mm) FIGURE 2 SERIES CONCEALED SPRINKLER INSTALLATION DIMENSIONS TFPI8I Page 3 of 4 Step 5. Replace the Protective Cap by pushing it upwards until it bottoms out against the Support Cup. (Refer to Figure 4.) The Protective Cap helps prevent damage to the Deflector and Arms during ceiling installation and/or finish. You can also use the Protective Cap to locate the center of the clear- ance hole by gently pushing the ceiling material up against the center point of the Protective Cap. EM As long as the Protective Cap remains in place, the system is considered "Out of Service" Step 6. After the ceiling has been completed with the 2-1/2 inch (63,5 mm) diameter clearance hole and in preparation for installing the Cover Plate/Retainer Assembly, remove and discard the Protective Cap. Verify that the Deflector moves up and down freely. If the Sprinkler is damaged and the Deflector does not move up and down freely, replace the entire Sprinkler. Do not attempt to modify or repair a damaged sprinkler. Step 7. When installing an Air and Dust Seal, refer to Figure 5; otherwise, proceed to Step 8. To attach the 'Air and Dust Seal, verify the angle of the outside edge of the seal is oriented according to Figure 5. Start the edge of the Retainer in the grooved slot of the Air and Dust Seal and continue around the retainer until the entire Air and Dust Seal is engaged. TFPI8I Page 4 of 4 SUPPORT SPRINKLER FACE OF ORIENT CUP CEILING -\ SEAL BEVEL AS COVER \ SHOWN PLATE RETAINER ASSEMBLY / \/ AIR AND DUST LIP OF COVER SEAL RETAINER PLATE FIGURE 5 OPTIONAL AIR AND DUST SEAL FOR SERIES RFII (TY3551) Step 8. Screw on the Cover Plate/ Retainer Assembly until the Retainer (shown in Figure 2) or the Air and Dust Seal (shown in Figure 5) contacts the ceiling. Do not continue to screw on the Cover Plate/Retainer Assembly so that it lifts a ceiling panel out of its normal position. If you cannot engage the Cover Plate/Retainer Assembly with the Support Cup or you cannot engage the Cover Plate/Retainer Assembly suf- ficiently to contact the ceiling, you must reposition the Sprinkler Fitting. Care and Maintenance The TYCO Series RFII 5.6 K-factor, "Royal Flush II" Concealed Pendent Sprinklers must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection system from the proper authorities and notify all personnel who may be affected by this action. Absence of the Cover Plate/Retainer Assembly can delay sprinkler opera- tion in a fire situation. When properly installed, there is a nominal 3/32 inch (2,4 mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 2. This air gap is necessary for proper operation of the sprinkler. If the ceiling requires repainting after sprinkler installation, ensure that the new paint does not seal off any of the air gap. Do not pull the Cover Plate relative to the Enclosure. Separation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be ainted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers - before, during, and after installation. Sprin- klers damaged by dropping, wrench twist/slippage, or the)ik must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installa- tion Section.) Exercise care to avoid damage to sprin- klers before, during, and after instal- lation. Replace sprinklers damaged by dropping, striking, wrench twist- ing, wrench slipping, or the like. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Refer to the Installation section.) If you must remove a sprinkler, do not reinstall it or a replacement without reinstalling the Cover Plate/Retainer Assembly. If a Cover Plate/Retainer Assembly becomes dislodged during service, replace it immediately. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or sprinkler manufac- turer regarding any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national code. Limited Warranty Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name. Sprinkler/Support Cup Assembly Specify: Series RFII (specify SIN), K=5.6, "Royal Flush II" Pendent Sprin- klers (specify) temperature rating and (specify) finish, P/N* (specify): 155°F (68°C) 200°F (93°C) TY3531 51-792-1-155 51-792-1-200 1Y3551 51-790-1-155 51-790-1-200 Use Suffix 'I" for ISO 7-1 connection; for example, 51-792-1-155-I Separately Ordered Cover Plate/ Retainer Assembly: Specify: (temperature rating from below) Series RFII Concealed Cover Plate with (finish), P/N (specify). 139°F (59°C)(a) 165°F (74°C)(b) Grey White (RAL9002) .... 56-792-0-135 56-792-0-165 Brass..........56-792-1-135 56-792-1-165 Pure White (c) (RAL9010) .... 56-792-3-135 56-792-3-165 Signal White (RAL9003) .... 56-792-4-135 56-792-4-165 Jet Black (RAL9005).... 56-792-6-135 59-792-6-165 Brushed Chrome ........56-792-8-135 56-792-8-165 Chrome ........56-792-9-135 56-792-9-165 Custom ........ 56-792-X-135 56-792-X-165 For use with 155°F (68°C) sprinklers. For use with 200°F (93°C) sprinklers. Eastern Hemisphere sales only. Sprinkler Wrench Specify: RFII Sprinkler Wrench, P/N 56-000-1-075 For warranty terms and conditions, visit Air and Dust Seal www.tyco-fire.com. Specify: Air and Dust Seal, P/N 56-908-1-001 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 Copyright © 2016 Tyco Fire Products, LP. All rights reserved. - t1co TEFLON is trademark of The DuPont Corporation Fire Protection Products Fire Protection Products Worldwide www.tyco-fire.com Contacts Series TY-FRB, 56 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY- FRB Pendent Sprinkler, where applica- ble, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 inch (15,9 mm) from the flush pendent position. A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 inch (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-FRB Sprinklers are described in Technical Data Sheet TFP357. Sprin- kler guards and shields are described in Technical Data Sheet TFP780. IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 IAI•)I(' The TYCO Series TY-FRB Sprinklers described herein must be installed and maintained in compliance with this doc- ument, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the stan- dards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY313 .......Upright 5.6K, 1/2" NPT TY323 ......Pendent 5.6K, 1/2" NPT Technical Data Approvals UL and C-UL Listed FM, LPCB, and VdS Approved CE Certified Sprinklers with Polyester Finish are UL and C-UL Listed as Corrosion-Resis- tant Sprinklers. Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar)* *The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Un- derwriters Laboratories, Inc. (UL). Discharge Coefficient K=5.6 GPM/p5i112 (80,6 LPM/bar112) FEBRUARY 2014 Temperature Rating 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) Finishes Sprinkler: Refer to Table A Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ...................Bronze Button..............Brass/Copper Sealing Assembly .........Stainless Steel w/TEFLON Bulb ......................Glass Compression Screw........Bronze Deflector.................Bronze TFPI72 TFPI72 Page 2of4 Components: 1 - Frame 2 - Button 3 - Sealing Assembly * Temperature rating is ** Pipe thread connections per ISO 7-1 4 - Bulb indicated on Deflector, can be provided on special request. 5 - Compression Screw ESCUTCHEON PLATE 1/2 7/16 (11,1 mm) 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN STYLE 15 or 20 RECESSED ESCUTCHEON 1 7/16 I (11,1mm) I NOMINAL MAKE-IN (50,8 mm) _____ 2° (50,8 mm) WF _________ F 1/2 NPT** DEFLECTOR * 2-7/8 (73,0 mm) DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES 1Y-FRB UPRIGHT (TY313) AND PENDENT (TY323) SPRINKLERS - 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon is to be used for recessed pendent installations. Installation The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) and 3/32 inch (2,4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a min- imum to maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TY-FRB Upright and Pen- dent Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. / WRENCH RECESS (USE ONLY FIGURE 2 W- TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W-TYPE 7 RECESSED SPRINKLER WRENCH TFPI72 Page 3 of 4 Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 2). With ref- erence to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate over the sprin- kler threads, and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Step C. After ceiling installation and fin- ishing, slide on the Style 15 or Style 20 Closure over the Series TY-FRB Sprin- kler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/ slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any other authorities hav- ing jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. 2-7/8" DIA. (73,0 mm) 2-1/4" DIA. FACE OF (57,2 mm) SPRINKLER FITTING 5/8" (15,9 mm) FLUSH 3/8±5/16 (9,5±7,9 mm) , , MOUNTING _J 1/8' J SURFACE - (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8 (34,9 mm) TY-FRB PLATE 3/4' (19,1 mm) FIGURE 4 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON 2-7/8" DIA. (73,0 mm) FACE OF SPRINKLER 2-1/4' DIA. FITTING (57,2 mm) 5/16±1/4" 1/2(12,7mm) (7,9±6,4 mm) FLUSH 17, J I MOUNTING 1/8" SURFACE/i \_ (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8" (34,9 mm) TYFRB PLATE 7/8" (22,2 mm) FIGURE 5 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON TEMPERATURE RATINGS 135 135°F (57°C) 155 155°F(68°C) 175 175°F(79°C) 200 200°F (93°C) 286 286°F (141°C) TFPI72 Page 4 of 4 P/N* 77-XXX-X-XXX SPRINKLER FINISH NATURAL BRASS SIN 1 370 5.6K UPRIGHT (1/2 NPT) TY313 3 PURE WHITE (RAL9010)°° POLYESTER SIGNAL WHITE (AAL9003) POLYESTER 371 5.6K PENDENT (1/2" NPT) TY323 4 CHROME PLATED Use suffix I" for ISO 7-1 connection; 9 for example, 77-370-4-175-I Eastern Hemisphere sales only TABLE A SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION Limited Warranty For warranty terms and Conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Num- ber (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB Upright or Pen- dent (specify) Sprinkler, SIN (specify), K=5.6, Quick Response, (specify) tem- perature rating, (specify) finish, P/N (specify, refer to Table A). Recessed Escutcheon Specify: Style 15 Recessed Escutcheon with (specify*) finish, P/N (specify*) Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (specify*) * Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS 1 1400 Pennbrook Parkway, Lansdale, PA 19446 1 Telephone +1-215-362-0700 Copyright © 2014 Tyco Fire Products, LP. All rights reserved. tqco TEFLON is trademark of The DuPont Corporation. Fire Protection Products Adif tqco F/re & Building IProducts Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 Series DS-1 — 56 K-factor Dry Type Sprinklers Quick Response, Standard Coverage General Description The TycoO Series DS-1, 5.6 K-factor, Quick Response, Standard Coverage, Dry Type Sprinklers are decorative 3 mm glass bulb automatic sprinklers de- signed for the following typical uses: where pendent sprinklers are re- quired on dry pipe systems that are exposed to freezing temperatures (e.g. sprinkler drops from unheated portions of buildings) where sprinklers and/or a portion of the connecting piping may be exposed to freezing temperatures (e.g. sprinkler drops from wet sys- tems into freezers, sprinkler sprigs from wet systems into unheated attics, or horizontal piping exten- sions through a wall to protect an unheated area of a building) where sprinklers are used on sys- tems that are seasonably drained to avoid freezing (e.g. vacation re- sort areas) WARNINGS The Series DS-1 Dry Type Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. The Series DS-1 Dry Type Sprinklers must only be installed in fittings that meet the requirements of the Design Criteria section. Model/Sprinkler Identification Numbers TY3235 - (Pendent) TY3135 - (Upright) TY3335 - (Horizontal Sidewall) :g j7 iqij Approvals UL and C-UL Listed. FM and NYC Approved. (Refer to Table A) Maximum Working Pressure 175 psi (12,1 bar) Inlet Thread Connection 1 inch NPT (Standard Order) ISO 7-Ri Discharge Coefficient K = 5.6 GPM/psi112 (80,6 LPM/bar112) Temperature Ratings Refer to Table A Finishes Sprinkler: Natural Brass, Chrome Plated, White Polyester Escutcheon: White Coated or Chrome Plated, Brass Plated (TT 1i Physical Characteristics Inlet......................Copper Plug .....................Copper Yoke ...............Stainless Steel Casing.....Galvanized Carbon Steel Insert ...................Bronze Bulb Seat ...........Stainless Steel Bulb.......................Glass Compression Screw.........Bronze Deflector .................Bronze Frame ....................Bronze Guide Tube ..........Stainless Steel Water Tube ..........Stainless Steel Spring ..............Stainless Steel Sealing Assembly................. Beryllium Nickel w/Teflon* Escutcheon ..........Carbon Steel *Registered Trademark of DuPont Patents U.S.A. Patent No. 5,188,185 Page 1 of 8 JANUARY, 2008 TFP5IO Page 2 of 8 TFP5IO SPRINKLER FINISH TY3235 Pendent TV3235 Pendent TY3335 Hor. Sidewall w/ Standard wl Std. Escutcheon with top of Recessed Escutcheon (Ref. Fig. 5) Deflector-to-Ceiling (Ref. Fig. 3) wl Deep Escutcheon distance of w/ Wide Flange (Ref. Fig. 6) 4 to 12 inches Recessed Escutcheon w/o Escutcheon (100 to 300 mm) (Ref. Fig. 4) (Ref. Fig. 7) w/ Std. Escutcheon (Ref. Fig. 9) w/ Deep Escutcheon TY3135 Upright (Ref. Fig. 10) w/o Escutcheon w/o Escutcheon (Ref. Fig. 8) (Ref. Fig. 11) Temperature Bulb Natural Chrome White Natural Chrome White Natural Chrome White Rating Color Code Brass Plated Polyester Brass Plated Polyester Brass Plated Polyester 135°F/57°C Orange 1, 2,3,4 1, 2,4 1, 2,3,4 1, 2,4 1*, 2*, 3", 4 1',2',4 155°F/68°C Red 1, 2, 3,4 1, 2, 4 1, 2, 3, 4 1, 2,4 l-,2',3--,4 1*, 2*, 4 175' 79 Yellow 1,2,3,4 1,2,4 1,2,3,4 1,2,4 1*,2*,3**,4 1*,2*,4 200'F/93'C Green 1,2,3,4 1,2,4 1, 2,3,4 1,2,4 1',2',3--,4 1*, 2, 4 286°F/141°C Blue N/A 1, 2,3, 4 1, 2, 4 1',2',3-',4 1', 2*, 4 Notes: Listed by Underwriters Laboratories, Inc (Maximum order length of 48 inches). Listed by Underwriters Laboratories for use in Canada (Maximum order length of 48 inches). Approved by Factory Mutual Research Corporation (Maximum order length of 48 inches) Approved by the City of New York under MEA 352-01-E. * Light and Ordinary Hazard Occupancies Only. ** Light Hazard Occupancies Only. N/A - Not Available. TABLE A SERIES DS-1, QUICK RESPONSE - STANDARD COVERAGE, DRY TYPE SPRINKLERS LABORATORY LISTINGS AND APPROVALS PLUG WITH INLET GASKETED SPRING PLATE SEAL - YOKE SPRING CASING II II WATER TUBE INSERT GUIDE TUBE BULB SEAT 77, FRAME 3 mm BULB VENT HOLE COMPRESSION DEFLECTOR SCREW FIGURE 1 SERIES DS-1 QUICK RESPONSE DRY TYPE SPRINKLER ASSEMBLY I WRENCH RECESS WRENCH FLAT PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCH FLATS FIGURE 2 W-TYPE 7 SPRINKLER WRENCH TFP5IO Page 3 of 8 SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) ,---- -------- FACE OF SPRINKLER L U FITTING r L i ORDER LENGTHS: 3-1/2 to 48" (88,9 to 1219,2 mm) IN 1/4 (6,4 mm) 2-1/4" DIA. INCREMENTS (57,2 mm) FACE OF CEILING iL 4 1-3/8" ± 1/8' 2-7/8" DIA. (34,9 ± 3,2 mm) FIGURE 3 TY3235 PENDENT wi STANDARD RECESSED ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) r --- FACE OF SPRINKLER L: FITTING L LjJ ___ L i ORDER LENGTHS: 3-1/2" to 48' (88,9 to 1219,2 mm) IN 1/4" (6,4 mm) 3" DIA. INCREMENTS (76,2 mm) FACE OF CEILING FIGURE 4 TY3235 PENDENT wi WIDE FLANGE RECESSED ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) n---,. --- FACE OF "T H SPRINKLER I FITTING ORDER LENGTHS: 2-1/2" to 48" 1-3/4" DIA. (63,5 to 1219,2 mm) (44,5 mm) IN 1/4" (6,4 mm) rj~l, INCREMENTS 11 I FACE OF cv CEILING 2-3/16" ± 1/8' 3" DIA. (76,2 mm) (55,6 ± 3,2 mm) FIGURE 5 TY3235 PENDENT wi STANDARD ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) ri FACE OF SPRINKLER FITTING ORDER LENGTHS: 3-1/2" DIA. 1/2' to 46" (88,9 mm) (12,7 to 1168,4 mm) 2-1/2' DIA IN 1/4' (6,4 mm) (63,5 mm) INCREMENTS 7 I FACE OF CEILING - 4-1/4' ±1/8' (108,0±3,2 mm) FIGURE 6 TY3235 PENDENT wi DEEP ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) r - FACE OF SPRINKLER L U FITTING f LI ORDER LENGTHS: 5" to 48" (127,0 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS MINIMUM 1-3/4' (44,5 mm) - DEFLECTOR TO CEILING FIGURE 7 TY3235 PENDENT w/o ESCUTCHEON TOP OF DEFLECTOR ORDER LENGTHS: 5" to 48" (127,0 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS FACE OF SPRINKLER FITTING SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FIGURE 8 TY3235 UPRIGHT wlo ESCUTCHEON ORDER LENGTHS: FACE OF 1/2" to 45-3/4" (12,7 toll 62,1 mm) MOUNTING IN 1/4 (6,4 mm) INCREMENTS SURFACE 4-13/16" ± 1/8' (122,2 ± 3,2 mm) 2-1/2" DIA. FACE OF (63,5 mm) SPRINKLER 1 FITTING JT 3-1/2' DIA. (88,9 mm) L] /350 SPRINKLER FITTING (REFER TO DESIGN CENTER LINE 5/16" CRITERIA SECTION) OF WATERWAY (7,9 mm) FIGURE 10 TY3335 HORIZONAL SIDEWALL wi DEEP ESCUTCHEON Page 4 of 8 TFP51b ORDER LENGTHS: 2-1/2 to 48" (63,5 to 1219,2 mm) IN 1/4 (6,4 mm) INCREMENTS 4±1/8 I (101,6 ± 3,2 mm) FACE OF FACE OF 1-3/4 DIA. - SPRINKLER MOUNTING -i (44,5 mm) FITTING SURFACE F1jE J_._ (76,2 mm) SPRINKLER FITTING (REFER TO DESIGN CENTERLINE 5/16' CRITERIA SECTION) OF WATERWAY (7,9 mm) WIJi¼lif When the Series DS-1 is in service, water is prevented from entering the assembly by the Plug & Belleville Seal- ing Assembly (Ref. Figure 1) in the Inlet of the Sprinkler. The glass Bulb contains a fluid that expands when exposed to heat. When the rated tem- perature is reached, the fluid expands sufficiently to shatter the glass Bulb, and the Bulb Seat is released. The compressed Spring is then able to ex- pand and push the Water Tube as well as the Guide Tube outward. This ac- tion simultaneously pulls inward on the Yoke, withdrawing the Plug & Belleville Seal from the Inlet allowing the sprin- kler to activate and flow water. FIGURE 9 TY3335 HORIZONAL SIDEWALL wi STANDARD ESCUTCHEON Design Criteria The Tyco® Series DS-1 Sprinklers are intended for use in fire sprinkler sys- tems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on NFPA 13 requirements). The 1 inch NPT Series DS-1 Sprin- klers are to be installed in the 1 inch NPT outlet or run of malleable or duc- tile iron threaded tee fittings that meet the dimensional requirements of ANSI B16.3 (Class 150) or cast iron threaded tee fittings that meet the dimension- al requirements of ANSI B16.4 (Class 125). The Series DS-1 Sprinklers may also be installed in the 1 inch NPT out- let of a Grinnell Figure 730 Mechani- cal Tee; however, the use of the Figure 730 for this arrangement is limited to wet pipe systems. Typically, the end sprinkler fitting on a branch line is plugged as shown in Figures 3 through 11. The DS-1 Sprin- klers cannot be installed into an elbow fitting. For wet pipe systems, the sprinkler drop may be installed as shown in Fig- ure 12. The configuration in Figure 12 may only be used where the sprinkler fitting and water filled pipe above the sprinkler fitting is not subject to freez- ing and where the length of the DS-1 Sprinkler has the minimum exposure length per Figure 14. For wet pipe systems, the DS-1 Sprin- klers may also be installed in the fol- lowing Tyco® CPVC fittings: (P/N 80145) 1" x 1" NPT Female Adapter or (P/N 80249) 1" x 1" x 1" NPT Sprinkler Head Adapter Tee. For dry pipe systems, only use the side outlet of maximum 2-1/2 inch size ORDER LENGTHS: 5-1/2" to 48" (139,7 to 1219,2 mm) IN 1/4' (6,4 mm) INCREMENTS FACE OF i.- SPRINKLER FITTING MINIMUM 2-1/4' (57,2 mm) DEFLECTOR TO MOUNTING SURFACE 5/16" SPRINKLER FITTING (7,9 mm) (REFER TO DESIGN CENTERLINE CRITERIA SECTION) OF WATERWAY FIGURE 11 TY3335 HORIZONAL SIDEWALL wlo ESCUTCHEON TFP5IO Page 5 of 8 reducing tee's when locating the DS- 1 Sprinklers directly below the branch line. Otherwise, use the configuration shown in Figure 13 to assure complete drainage of water from above the DS-1 Sprinklers and the branch line. NOTE Do not install the Series DS-1 into any other type fitting without first consult- ing the Technical Services Depart- ment. Failure to use the appropriate fitting may result in: failure of the sprin- kler to properly operate due to forma- tion of ice over the inlet Plug or bind- ing of the inlet Plug; or, insufficient engagement of the inlet pipe threads with consequent leakage. Branch, cross, and feedmain piping connected to Dry Sprinklers and sub- ject to freezing temperatures must be pitched for drainage in accordance with the minimum requirements of the National Fire Protection Association for dry pipe sprinkler systems. When Dry Sprinklers are to be used in wet pipe sprinkler systems protect- ing areas subject to freezing tempera- tures (e.g., sprinkler drops into freez- ers), consideration must be given to the appropriate length of the sprinkler that will prevent freezing of the water in the connecting pipes due to conduc- tion. When the temperature surround- ing the wet pipe sprinkler system is maintained at a minimum temperature of 40°F/4°C, the following are the mini- mum recommended lengths between the face of the sprinkler fitting and the outside surface of the protected area (i.e., length exposed to minimum am- bient of 40°F/4°C - Ref. Figure 14): 12 inches (300 mm) when the tem- perature within the protected area is -20°F/-29°C 18 inches (450 mm) when the tem- perature within the protected area is -40°F/-40°C 24 inches (600 mm) when the tem- perature within the protected area is -60°F/-51°C For protected area temperatures between those given above, the mini- mum recommended length from the face of the fitting to the outside of the protected area may be determined by interpolating between the indicated values. The 2007 edition of NFPA 13, Sec- tion 8.4.10.2 requires that dry sprin- klers connected to wet pipe sprinkler systems protecting insulated freezer structures have the clearance space around the sprinkler barrel be sealed. The use of the Model DSB-2 Dry Sprinkler Boot described in Technical Data Sheet TFP591, and illustrated in Figures 15 and 16, will meet the intent of NFPA 13. TO WET SIDE SYSTEM OUTLET PLUGGED HEATED AREA 1 INCH DSB-2 NPT TEE INTENDED (SEE DESIGN FOR FREEZER CRITERIA STRUCTURES SECTION) 7 7 0 _A_- I J FIGURE 12, SPRINKLER FITTING IN HEATED AREA RUN OUTLET PLUGGED 1 INCH NFTEE TO DRY SYSTEM (SEE DESIGN CRITERIA AREA I SECTION) I SUBJECT I TO I DSB-2 INTENDED FOR FREEZER I FREEZING I STRUCTURES FIGURE 13, SPRINKLER FITTING IN UNHEATED AREA FACE OF SPRINKLER Ifl FITTING HEATED POSURE AREA LENGTH (SEE DESIGN DSB-2 CRITERIA INTENDED SECTION) FOR FREEZER STRUCTURES AL _Ic ICJ FIGURE 14, EXPOSURE LENGTH STRAP TIES (ENDS ON ,- OPPOSING / SIDES OF / BOOT) I / DSB-2 BOOT J ADHESIVE 1-3/4 DIA. (44,5 mm) I CLEARANCE HOLE I INSULATED I FREEZER STRUCTURE L1J DS-1 SHOWN WITH STANDARD ESCUTCHEON FIGURE 15 MODEL DSB-2 SPRINKLER BOOT WITH PENDENT SERIES DS-1 DRY SPRINKLER 1-3/4" DIA. (44,5 mm) CLEARANCE INSULATED HOLE FREEZER ADHESIVE TURE DSB-2 BOOT STRAP TIES 7 DS-1 (ENDS ON SHOWN WITH OPPOSING STANDARD SIDES OF ESCUTCHEON BOOT) FIGURE 16 MODEL DSB-2 SPRINKLER BOOT WITH SIDEWALL SERIES DS-1 DRY SPRINKLER Page 6 of 8 TFP51b' Installation The Series DS-1 Dry Type Sprinklers must be installed in accordance with the following instructions: NOTES The Series DS-1 must only be installed in fittings that meet the requirements of the Design Criteria section. Refer to the Design Criteria section for other important requirements regard- ing piping design and sealing of the clearance space around the Sprinkler Casing. Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F/570C rating to 1/8 inch (3,2 mm) for the 2860F/141°C rating. A 1 inch NPT sprinkler joint should be obtained with a minimum to maximum torque of 20 to 30 ft. lbs. (26,8 to 40,2 Nm). Higher levels of torque may dis- tort the sprinkler inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in an Escutcheon Plate by under-or over-tightening the Sprinkler. Readjust the position of the sprinkler fitting to suit. Step 1. Pendent sprinklers must be installed only in the pendent posi- tion, and upright sprinklers must be in- stalled only in the upright position. The deflector of a pendent or upright sprin- kler is to be parallel to the ceiling. Horizontal sidewall sprinklers are to be installed in the horizontal position with their centerline of waterway perpen- dicular to the back wall and parallel to the ceiling. The word "TOP" on the De- flector is to face towards the ceiling. Step 2. With pipe thread sealant ap- plied to the inlet threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Wrench tighten the sprinkler by wrenching on the Casing with a pipe wrench whenever the casing is readily accessible. Otherwise, use a W-Type 7 Sprinkler Wrench (Ref. Figure 2). The wrench recess of the W-Type 7 is to be applied to the sprinkler wrench flats (Ref. Figure 2). Step 4. After the ceiling/wall has been installed/finished, slide on the outer piece of the Escutcheon until it comes in contact with the ceiling/wall. Do not lift the ceiling panel out of its normal position. In the case of the outer piece of the Deep Escutcheon, hold the outer piece in contact with the mounting sur- face (ceiling), and then rotate the in- ner piece approximately 1/4 turn with respect to the outer piece, to hold the Deep Escutcheon firmly together. Care and Maintenance The Tycoll Series DS-1 Dry Type Sprin- klers must be maintained and ser- viced in accordance with the following instructions: NOTES Absence of the outer piece of an es- cutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Before closing a fire protection sys- tem main control valve for mainte- nance work on the fire protection sys- tem that it controls, permission to shut down the affected fire protection sys- tems must be obtained from the prop- er authorities and all personnel who may be affected by this action must be notified. A Vent Hole is provided in the Bulb Seat (Ref. Figure 1) to indicate if the Dry Sprinkler is remaining dry. Evidence of leakage from the Vent Hole is an indi- cation that there may be weepage past the Inlet seal and that the sprinkler needs to be removed for determining the cause of leakage (e.g. an improp- er installation or an ice plug). The fire protection system control valve must be closed and the system drained be- fore removing the sprinkler. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be com- pletely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age -before, during, and after instal- lation. Sprinklers damaged by drop- ping, striking, wrench twist/slippage, or the like, must be replaced. Also, re- place any sprinkler that has a cracked bulb or that has lost liquid from its bulb (Ref. Installation Section). The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and devic- es in compliance with this document, as well as with the applicable stan- dards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any other authori- ties having jurisdiction. The installing contractor or sprinkler manufacturer should be contacted relative to any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national codes. TFP5IO Page 7 of 8 Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warran- ty is given for products or components manufactured by companies not af- filiated by ownership with TFBP or for products and components which have been subject to misuse, improper in- stallation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protec- tion Association, and/or the standards of any other Authorities Having Juris- diction. Materials found by TFBP to be defective shall be either repaired or re- placed, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other ob- ligation in connection with the sale of products or parts of products. TFBP shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties, ex- press or implied, including warranties of merchantability and fitness for a particular purpose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure Dry Sprinklers: Contact your local distributor for availability, and please specify the following: 1. Sprinkler. Model/SIN. Quick Response, Standard Cover- age, Dry Type Sprinkler Deflector Style. 5.6 K-factor. Order Length. Dry Type Sprinklers are furnished based upon Order Length as mea- sured per Figure 3 through 11, as applicable. After the measurement is taken, round it to the nearest 1/4 inch. increment. Inlet Connection (1 Inch NPT or ISO 7-Ri). Temperature Rating. Sprinkler Finish. Escutcheon Style and Finish, as applicable. Part Number from Table B. (Part numbers are for 1 inch NPT stand- ard order sprinklers. Orders for all other sprinkler assemblies must be accompanied by a complete description.) 2. W-Type 7 Sprinkler Wrench. Refer to the Price List for complete listing of Part Numbers. Model DSB-2: Specify: Model DSB-2 Dry Sprinkler Boot*, P/N 63-000-0-002. * Includes one Boot, two Strap Ties, and 1/3 oz. of Adhesive (quantity of adhesive is sufficient for installing one Boot) I L LENGTH ORDER (1) (EXAMPLES) 055 5.50" 082 8.25" 180 18.00" 187 18.75" 372 37.25" 480 48.00" ESCUTCHEON FINISH (2) WHITE WHITE CHROME WHITE WHITE (RAL9010)" BRASS PLATED Page 80f8 TFP51U" P/N 60- XXX- X- XXX SPRINKLER FINISH MODEL/SIN 1 NATURAL BRASS 4 WHITE POLYESTER 9 CHROME PLATED 0 CHROME PLATED 3 WHITE (RAL9010)* 2 NATURAL BRASS 36 Pendent wl Standard TY3235 Escutcheon (1" NPT) (Fig. 5) 33 Pendent w/ Deep TY3235 Escutcheon (1" NPT) (Fig. 6) 37 Pendent wl Std. Recessed TY3235 Escutcheon (1" NPT) (Fig. 3) r 32 Pendent w/o Escutcheon TY3235 (1" NPT) (Fig. 7) 34 Sidewall wl Standard TY3335 Escutcheon (1" NPT) (Fig. 9) 43 Sidewall wl Deep TY3335 Escutcheon (1" NPT) (Fig. 10) 44 Sidewall w/o TY3335 Escutcheon (1" NPT) (Fig. 11) 38 Upright w/o Escutcheon 1Y3135 (1" NPT) (Fig. 8) TEMPERATURE RATING (3) 135°F/57°C 1 155°F/68"C 2 175°F/79°C 3 200°F/93°C 4 286°F/141"C NOTES Dry Type Sprinklers are furnished based upon "Order Length" as measured per Figures 3 through 11, as applicable, and for each individual sprinkler where it is to be installed. After the measurement is taken, round it to the nearest 1/4 inch increment. Escutcheon Finish applies to sprinklers provided with escutcheons. 286F/141 C temperature rating applies to non-recessed sprinkler assemblies. * Eastern Hemisphere sales only TABLE B PART NUMBER SELECTION SERIES DS-1, QUICK RESPONSE, STANDARD COVERAGE, DRY TYPE SPRINKLERS (Use Prefix "I" for ISO 7-RI Connection, e.g., 1-60-361-1-180) © 2007-2008 TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale Pennsylvania 19446 EXISTING - FOR REFERENCE ONLY APPLICATION Designed for installation on potable water connections in fire ' sprinkler systems to protect against both backsiphonage and backpressure of polluted water into the potable water supply. Model 350DA shall provide protection where a potential health hazard does not exist. Incorporates metered by-pass to detect -' leaks and unauthorized water use. STANDARDS COMPLIANCE (Sizes 2 112"-10" Horiz. & Vert.) FEATURES (12" Horizontal Only) Sizes: U 2 1/2" U 3" U 4" U 6" U 8" U 10" U 12" Maximum working water pressure 175 PSI Maximum working water temperature 140°F Hydrostatic test pressure 350 PSI End connections (Grooved for steel) AWWA C606 (Flanged) ANSI 816.1 Class 125 OPTIONS (suffixes can be combined) U - with OS & Y gate valves (standard) U L - less shut-off valves (flanged body connections) U LM - less water meter U - with remote reading meter U - with gpm meter (standard) U CFM - with cu ft/min meter U G - with groove end gate valves U FG - with flanged inlet gate connection and grooved outlet gate connection U P1 - with Post Indicator Gate Valve (3-10") ACCESSORIES U Repair kit (rubber only) U Thermal expansion tank (Model XT) U OS & Y Gate valve tamper switch (OSY-40) U Test Cock Lock (Model TCL24) ASSE® Listed 1048 (Sizes 2 1/2" thru 12") GSA® Certified B64.5 (Sizes 2 1/2" thru 8') AWWA Compliant G510 (Sizes 2 1/2" thru 12") LJL® Classified (Sizes 2 1/2" thru 12) C-UL® Classified (Sizes 2 1/2" thru 12") FM® Approved (Sizes 2 1/2" thru 10') NYC MEA 147-99-M Vol 4 (2-1/2" - 10) * Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California (Sizes 2 1/2" thru 10') MATERIALS Main valve body Ductile Iron ASTM A 536 Grade 4 Access covers Ductile Iron ASTM A 536 Grade 4 Coatings FDA Approved fusion epoxy finish Internals Stainless steel, 300 Series NORYLTM, NSF Listed Fasteners Stainless Steel, 300 Series Elastomers EPDM (FDA approved) Buna Nitrile (FDA approved) Polymers NORYLTM, NSF Listed Springs Stainless Steel, 300 Series Attention: Model 350DA (flange body) and Model 350ADA (grooved body) have different lay lengths. A A DIMENSIONS & WEIGHTS (do not include pkg.) MODEL 350DAG SHOWN ABOVE DIMENSION ___________ __________ _(approximate) WEIGHT MODEL 350DA SIZE in. mm A in. mm B LESS GATE VALVES in. mm C in. I mm D in. I mm E OS&Y OPEN in. I mm E OS&Y CLOSED in. mm F in. mm WITHOUT GATES VALVES lbs. kg WITH OS&Y GATE VALVES UDS. I kg 21/2 65 31 787 157/8 403 33/4 95 9 229 163/8 416 137/8 352 31/2 89 68 30.9 178 80.8 3 80 1 32 813 8 403 13314 95 9 229 187/8 479 155/8 397 31 89 1 68 30 8 90 4100375/8 956 2 4954149 229 223/4 578 181/4 4646 152 106 48 2964 6 150 443/4 1137 231/2 597 51/2 140 101/2 267 301/8 765 233/4 603 7 178 180 81.7 480 217.9 8 200 603/4 43 4 959 W 254 12 305373/4 959 291/4 743 82 2 374 170 850 389 10 250 633/4 959 W 254 305 453/4 2 353/8 899 82 6 404 22 958 12 300 661/4 3 395531/8 1349 405/8 1032 8 2W 1623 736.2 Page 1 of 2 WILKINS a Zurn Company, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805/238-7100 Fax:805/238-5766 In Canada: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 1L2 Phone:905/405-8272 Fax:905/405-1292 Product Support Help Line: 1-877-BACKFLOW (1-877-222-5356) " Website: http:/Iwww.zurn.com 0 VERTICAL INSTALLATION FLOW CHARACTERISTICS MODEL 350DA 2 1/2",3" & 4" (STANDARD & METRIC) FLOW RATES (us) 0.0 12.6 25.2 37.9 15 LU 10 00 -.------ — — 800 157.7 103 U) 0 _____ 69 LLI —I mm) 34 u_i a- 2500 252.4 283.9 50.5 103 0, 0 69 ci 34 U) W a- (1 0.0 Cl) 15 Cl) 0 :: 610 U) ci) 5 W a- A 200 400 600 FLOW RATES (GPM) MODEL 350DA 6" & 8" (STANDARD & METRIC) FLOW RATES (us) 31.5 63.1 94.6 126.2 0 500 1000 FLOW RATES (GPM) 1500 2000 MODEL 350DA 10" & 12" (STANDARD & METRIC) FLOW RATES (us) 0.0 31.5 63.1 94.6 126.2 157.7 189.3 220.8 500 1000 1500 2000 2500 3000 3500 FLOW RATES (GPM) 103 U) 0 -J o 34 W 0 4000 4500 -- — — — — — — -- -- -- -- — — — — - - -- -- — — — — — — — -- -- — — — — -- — -- --_-_-_-_, — — -- - — — —— — — — -- . — - --- —- — — — — -- - - — — — — — — -- -- — — — — — -_- -- -- — —_—_— — — — -- -- — — -_- — -_- -- TYPICAL INSTALLATION Local codes shall govern installation requirements. Unless other- wise specified, the assembly shall be mounted at a minimum of 12" (305mm) and a maximum of 30" (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. Capacity thru Schedule 40 Pipe (GPM) Pipe size 5 ft/sec 7.5 ft/sec 10,ftlsec 15 ft/sec 2 1/2" 75 112 149 224 115 173 230 346 198 298 397 595 6' 450 675 900 1351 8" 780 1169 1559 2339 10" 1229 1843 2458 3687 12" 1763 2644 3525 5288 OUTDOOR INSTALLATION SPECIFICATIONS The Double Check Detector Backflow Prevention Assembly shall be ASSE® Listed 1048, and supplied with full port gate valves. The main body and access cover shall be epoxy coated ductile iron (ASTM A 536 Grade 4), the seat ring and check valve shall be NoryITM (NSF Listed), the stem shall be stainless steel (ASTM A 276) and the seat disc elastomers shall be EPDM. The first and second check valves shall be accessible for maintenance without removing the device from the line. The Double Check Detector Backflow Prevention Assembly shall be a WILKINS Model 350DA. WILKINS a Zum company, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805/238-7100 Fax:805/238-5766 In Canada: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 11-2 Phone:905/405-8272 Fax:905/405-1292 Product Support Help Line: 1-877-BACKFLOW (1-877-222-5356) " Website: http://www.zurn.com Page 2 of 2 FPC2017-023 2525 EL CAMINO REAL YARD HOUSE - SPRINKLER TI >100 HEADS (96) #208 tqca SFmplexGthrnell NTRACTOR'S MATERIAL AND TEST CERTIFICATE FOR ABOVEGROUND PIPING NFPA 13 - Sprinkler Systems PROCEDURE Upon completion of work, inspection and tests shall be made by the contractor's representative and witnessed by the property owner or their authorized agent. All defects shall be corrected and system left in service before contractor's personnel finally leave the job. A certificate shall be filled out and signed by both representatives. Copies shalt be prepared for approving authorities, owners, and contractor. It is understood the owner's representatives signature in no way prejudices any claim against contractor for faulty material, poor workmanship, or failure to comply with approving authority's requirements or local ordinances. Property name: Yard House Date: Nov 15, 2017 Property address:"2525ElTCãmino Real Carlsbad, CA 92008 Space208— Plans Accepted by approving authorities (names): The City of Carlsbad RECEIVED Address: 1635 faraday Ave. NOV 16 2017 Installation conforms to accepted plans? Eg Yes El No CARLSBAD Equipment used is approved? Z Yes 0 No FIRE DEPARTMENT If no, explain deviations: Instructions Has person in charge of fire equipment been instructed as to location of Yes n No control valves and care and maintenance of this new equipment? If no, explain: Have copies of the following been left on the premises? Training & Instructions Comments: System components instructions El Yes El No El Yes 0 No El Yes N No Copies to be left by installing contractor of the mall system Care and maintenance instructions NFPA 25 Location of System . - Supplies buildings: Make Model SIN Year of K-Factor NPT rating Quantity Manuf. Tyco RF II TY 3537 2017 5.6 1/2" 155 57 Tyco TY-FRB TY 323 2017 5.6 1/2" 200 22 Sprinklers Tyco DS-1 1Y3235 2017 5.6 1" 200 14 Pipe and Fittings Type of pipe: Black Sch. 40 steel Type of fittings: Anvil Cast Iron Alarm Device Minimum time to operate through test connection Alarm Valve or Flow Indicator Type Make Model Minutes Seconds Aboveground Test Certificate, adapted from NFPA 13- 2013 Edition NFPA 13 (p. 1 013) 4 D" Pipe Operating Test Dry valve Q.O.D. Make Model Serial no. Make Model Serial no. NA NA NA NA I NA NA Time to trip through ab test connection Water pressure Air pressure Trip point air pressure Time water reached test outlet a,u Alarm operated properly Min Sec PSI PSI PSI Min Sec Yes No MthOut 0.0.0. Wth Q.O.D. a Measured from time inspector's test connection is opened. bNFpA 13 only requires the 60-second limitation in specific sections Operation: [1 Pneumatic 0 Electric El Hydraulic El Manual Piping Supervised? 0 Yes 0 No Detecting Media Supervised? El Yes 0 No Does valve operate from the manual trip, remote, or both control actions? El Yes El No Deluge and Is there an accessible facility in each circuit for testing? D Yes 0 No Preaction Valves If no, explain: Does Each Circuit Operate Supervision Loss Alarm Does Each Circuit Maximum Time to Operate Valve Release? Operate Release? Make Model Yes No Yes No Min Sec Pressure Reducing Location and Floor Make and model Setting Static pressure Residual pressure Flow rate Test (flowing) Valve Inlet (psi) Outtet (psi) Inlet (psi) j0utlet (psi) (gpm) ___________ Test Hydrostatic: Hydrostatic tests shall be made at not less than 200 psi (13.6 bar) for 2 hours or 50 psi (3.4 bar) above static pressure in excess of 150 psi (10.2 bar) for 2 hours. Differential dry pipe valve clappers shall be left open during the test to prevent damage. All aboveground piping leakage shall be stopped. Descriptions Pneumatic: Establish 40 psi (2.7 bar) air pressure and measure drop, which shall not exceed lYs psi (0.1 bar) in 24 hours. Test pressure tanks at normal water level and air pressure and measure air pressure drop, which shall not exceed 11/2 psi (0.2 bar) in 24 hours. All system piping hydrostatically tested at: 200 psi for 2 hours Z Yes D No Dry system piping pneumatically tested at: psi for hours Yes 0 No Dry pilot piping' pneumatically tested at: psi for hours []Yes 0 No *Dry pilot piping shall be pneumatically (air) tested only (no water) If no, explain: Equipment operates properly? 0 Yes 0 No Do you certify as the installing contractor that additives and corrosive chemicals, sodium silicate or 0 Yes derivatives of sodium silicate, brine, or other corrosive chemicals were not used for testing systems or stopping leaks? El No Tests Main Drain Test Reading of gauge located near water supply test connection: psi [Residual pressure with valve in test connection open wide: psi Underground main and lead-in connections to system risers x Yes No flushed before connection made to sprinkler piping? Verified by copy of the Contractor's Material and Yes El No Test Certificate for Underground Piping? Flushed by installer of underground sprinkler piping? I1 Yes 0 No Other, explain: If powder-driven fasteners are used in concrete, has Yes No representative sample testing been satisfactorily completed? If no, explain: tq Aboveground Test Certificate, adapted from NFPA 13- 2013 Edition NFPA 13 (p. 2 of 3) Blank Testing Gaskets Number used: 0 ______I I Locations: NA I Number removed: Welded Piping? El Yes M No If yes... Do you certify as the sprinkler contractor that welding procedures used El Yes El No complied with the minimum requirements of AWS B2. 1, ASME Section IX, Welding and Brazing Qualifications, or other applicable qualification standard as required by the AHJ? Do you certify that all welding was performed by welders or welding operators fl Yes El No qualified in accordance with the minimum requirements of AWS B2. 1, ASME Section IX, Welding and Brazing Qualifications, or other applicable qualification Welding standard as required by the AHJ? Do you certify that the welding was conducted in compliance with a El Yes El No documented quality control procedure to ensure that (1) all discs are retrieved; (2) that openings in piping are smooth, that slag and other welding residue are removed; (3) the internal diameters of piping are not penetrated; (4) completed welds are free from cracks, incomplete fusion, surface porosity greater than i% in. diameter, undercut deeper than the less of 25% of the wall thickness or i/ in.; and (5) completed circumferential butt weld reinforcement does not exceed 3/32 in.? Cutouts Do you certify that you have a control feature to ensure that all cutouts (discs) Yes El No (discs) are retrieved? Hydraulic Data Nameplate provided? I Nameplate ll Yes El No I hf no, explain: Caps and Straps Sprinkler contractor removed all caps and straps? EI Yes El No Remarks Date left in service with all control valves open: 11/15/17 Name of sprinkler contractor: SimplexGrinnell Tests Witnessed by I érty owner or a- d-aent (signed) Signaturq Date Property owner or authorized agent (signed) Title Date -I, fly lnstalla'Tion sprin itractor (signed) Titl Date Additional explanations/notes: Yardhouse system was a TI only of an existing Shell system installed by others. Aboveground Test Certificate, adapted from NFPA 13 2013 Edition NFPA 13 (p. 3 of 3)