HomeMy WebLinkAbout5800 THE CROSSINGS DR; ; FPC2019-0186; PermitJ1iZuIJITl:i (City of Carlsbad Print Date: 10/24/2022 Permit No: FPC2019-0186 Job Address: 5800 THE CROSSINGS DR, CARLSBAD, CA 92008-4717 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2122700100 Track #: Applied: 08/05/2019 Valuation: $0.00 Lot #: Issued: 08/19/2019 Occupancy Group: Project #: Finaled Close Out: 11/21/2019 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check #:. INSPECTOR: Salcedo, Felix Plan Check #: Project Title: Description: THE CROSSINGS -REPLACE ALARM CONTROL PANEL & NAC BOOSTER (ADD NEW CELLULAR DIALER) Applicant: FPContractor: COSCO FIRE PROTECTION INC COSCO FIRE PROTECTION INC JOHN MOCKER 1075 W LAMBERT RD 4990 GREENCRAIG LN BREA, CA 92821-2944 SAN DIEGO, CA 92123-1673 (858) 444-2000 (858) 444-2000 FEE AMOUNT FIRE TI Fire Alarm System $620.00 Total Fees: $620.00 Total Payments To Date: $620.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov DF-60334:A6 • Al-i 00 MS19600 LS( E )/MS'9600U DLS( E) j!j FIreLITeALarms Intelligent Addressable FACP with Optional Second Loop by Honeywell [.777777 777777L 7 General Fire-Lite's MS-9600LS(E) and MS-9600UDLS(E) are compact, cost effective, intelligent addressable FACPs (Fire Alarm Control Panels) with an extensive list of powerful features. The combination of Fire-Lite's newer series devices and legacy 300 Series devices, along with the MS-9600LS(E) or MS-9600UDLS(E) FACP, offer the latest in fire protection technology. LiteSpeedTm is a patented tech- nology that polls 10 devices at a time looking for new or different information. When new information is found at a specific address, the system polls that device several times for any new data. This improvement allows a fully loaded panel with up to 636 devices to report an incident and activate the notification circuits in under 10 seconds. With this polling scheme, devices can be wired on stan- dard twisted, unshielded wire up to a distance of 10,000 feet per loop. Each Signaling Line Circuit (SLC) loop supports up to 159 addressable detectors including photoelectric, photoelectric with heat, beam, ionization, photoelectric duct, fixed heat, fixed heat with rate-of-rise, and fixed high-heat detectors. It also supports up to 159 addressable modules including monitor (two-wire detector, normally open devices), dual-monitor functions (two monitor circuits from one module, two addresses used), multi-monitor (multiple monitor cir- cuits from one module, multiple addresses used), control (for Notifi- cation Appliance Circuits), and relay (two Form-C) modules. The FLPS-7 power supply is a separate board while all other elec- tronics are contained on a single main circuit board. Both boards are mounted to a quick-removable chassis and housed in a metal cabi- net. The backbox can be installed allowing field wiring to be pulled. When construction is completed, the chassis with the electronics can be quickly installed with two bolts. The MS-9600UDLS(E) includes a factory-installed 2 Digital Alarm Communicator Transmitter. The DACT transmits system status (alarm, troubles, AC loss, etc.) to a Central Station via internet (optional IPDACT installed) or the public switched telephone net- work. Optional modules, which plug into the main circuit board, are avail- able for special functions. Available accessories include LED, graphic and LCD annunciators, reverse polarity/city box transmitter, digital alarm communicator/transmitter, SLC expansion module, local and remote upload/download software and remote power expansion. FM APPROVED to UL ANSI 864. NOTE: Unless otherwise specified, the term MS-9600LS is used in this document to refer to the MS-9600LS, MS-9600UDLS, MS-9600LSE, and MS-9600UDLSE FACP5 (Fire Alarm Control Panels). Controls And Indicators LED INDICATORS AC POWER (green) FIRE ALARM (red) SUPERVISORY (yellow) ALARM SILENCED (yellow) SYSTEM TROUBLE (yellow) MAI NTENANCE/PRES IGNAL (yellow) DISABLED (yellow) BATTERY FAULT (yellow) GROUND FAULT (yellow) MEMBRANE SWITCH CONTROLS ACKNOWLEDGE/STEP ALARM SILENCE DRILL SYSTEM RESET (lamp test) 12-key pad with full alphabet 4 cursor keys ENTER Special Features Easy mount chassis. 7 amp switching power supply. Large enclosure allows 18 amp-hour batteries 2 plug-in communicator standard with MS-9600UDLS/E. Optional IPDACT Internet Protocol Digital Alarm Communicator/ Transmitter Four Style Y (Class B) or two Style Z (Class A) NAC circuits. Selectable strobe synchronization per NAC for System Sensor, Wheelock, and Gentex devices. Certified for seismic applications when used with the appropriate seismic mounting kit Seamless integration between fire and mass notification with the ECC-50/100 Emergency Command Center via ANN-BUS con- nections. ECC-FFT Firefighter Telephone Option ANN-BUS for connection to following optional modules Note: cannot be used if ACS annunciators are used. - ANN-80(-'P) Remote LCD Annunciator - ANN-I/O LED Driver Module - ANN-S/PG Serial/Parallel Printer Module DF-60334:A6 •2/20/2019 - Page 1 of 6 - ANN-RLY Relay Module - ANN-LED Annunciator Module - ANN-RLED Annunciator Module (alarms only) Compatible with SWIFT® wireless devices Standard Features SLC LOOP SLC can be configured for NFPA Style 4, 6, or 7 operation. SLC supports up to 318 addressable devices per loop (15 detectors and 159 monitor, control, or relay modules). SLC loop maximum length 10,000 ft. (3,048 m) @ 12 AWG (3.1 mm2) using twisted, unshielded wire (see Wire Table on page 5). NOTIFICATION APPLIANCE CIRCUITS (NACS): Four onboard NACs with additional NAC capability using output control modules (CMF-300 or CMF-300-6). The four Class B NACs can be converted to two Class A NACs with the NACKEY (included). Silence Inhibit and Auto Silence timer options. Continuous, March Time, Temporal or California code for main circuit board NACs with two-stage capability. Selectable strobe synchronization per NAC. 3.0 amps special application, 300mA regulated maximum per each NAC circuit Note: Maximum 24 VDC system power output is shared among all NAC circuits and 24 VDC special application auxiliary power outputs. Total available output is 7.0 amps. ADVANCED FIRE TECHNOLOGY: Sensitivity testing with printable results, on-site or off-site. Automatic drift compensation. PROGRAMMING AND SOFTWARE: Autoprogramming (learn mode) reduces installation time. Fully programmable from local keypad, local PS/2 keyboard or PC (using the standard PS-Tools Windows® utility). Two-level user-programmable passwords. Custom English labels (per point) may be manually entered or selected from an internal library file. Three Form-C relay outputs (two programmable). 99 software zones. USER INTERFACE: Optional plug-in 2 communicator (standard with MS- 9600UDLS(E) with USB port for local upload/download. Remote Acknowledge, Silence, Reset and Drill via addressable monitor modules, ACS Series annunciators, LCD-80F remote annunciator, or ANN-80 Series Annunciators. EIA-232 printer/PC interface (variable baud rate) on main circuit board. Integral 80-character LCD display with backlighting. Real-time clock/calendar with automatic daylight savings adjust- ments. History file with 1,000-event capacity. EIA-485/ANN-BUS supporting up to 8 ANN Series Annunciators or 32 ACS Series annunciators. EIA-485 supporting up to 32 ACS annunciators. Maintenance alert warns when smoke detector dust accumula- tion is excessive. Automatic device type-code verification. One person audible or silent walk test with walk-test log and print- out. Point trouble identification. Local piezo sounder. Waterilow (non-silenceable) selection per monitor point. System alarm verification selection per detector point. PAS (Positive Alarm Sequence) and presignal delay per point (NFPA 72 compliant). Optional 4XTMF module (conventional reverse polarity/city box transmitter). Field-programming Features Off-line Programming: Create the entire program in your office using a Windows®-based software package (download PS-Tools from www.firelite.com). Upload/download system programming locally to the MS-9600L5 in less than one minute. Autoprogramming: Command the MS-9600L5 to program itself (takes less than 30 seconds). In the Auto-Program mode, the MS- 9600L5 scans for all possible devices at all addresses, stores the device types, and addresses found, and then loads default values for all options (General Alarm). It also checks for two or more devices set to the same address. Online Editing: While still providing fire protection, the MS-9600LS/ E may be programmed from the front panel. Simple menu trees dis- played on the LCD allow the trained user to perform all functions without referring back to the programming manual. English Label Library: Quickly select labels from a standard library of more than 50 adjectives/nouns, such as "FLR 3 HALLWAY," or enter custom labels letter-by-letter. Use recall function to repeat pre- viously used label. Program Check: Automatically catch common errors, such as con- trol modules not linked to any zone or input point. Maintenance Alert The MS-9600L5(E) continuously monitors each smoke detector and is capable of reporting maintenance conditions. This reduces the risk of false alarms due to dust accumulation. Refer to the control panel installation manual for more information. Automatic Test Operation The MS-9600L5(E) performs an automatic test of each detector every two hours. Failure to meet the test limits causes an AUTO TEST FAIL trouble type. System Reset clears this trouble. Terminal Blocks AC Power - TBI: 120 VAC, 60 Hz, 3.0 amps or 240 VAC, 50 Hz, 1.5 amps. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insu- lation. Battery (lead acid only) - TB2: Maximum charging circuit: Normal float charge 27.6 VDC @ 1.0 amp. Maximum battery charger capac- ity: 26 AH. Minimum battery 12 AH. MS-9600L5 cabinet holds maxi- mum of two 18 AH batteries. For 26 - 120 AH batteries, use the CHG-120F or CHG-75 Battery Charger and BB-55F Battery Box. NOTE: Jumper JP3, on the FACP main circuit board, must be cut to dis- able the FACP battery charger when using the CHG-120F or CHG-75. Communication Loop - (standard) TB8: 24 VDC nominal, 27.6 VDC maximum. Maximum length: 10,000 ft. (3048 m) total twisted, unshielded pair length. Maximum loop current: 400 mA (short circuit) or 100 mA (normal). Maximum loop resistance: 40 ohms. Super- vised and power-limited. Notification Appliance Circuits - TB4: Power-limited circuitry. Nominal operating voltage: 24 VDC. Current limit: fuseless, elec- tronic, power-limited circuitry. Maximum signaling current per circuit: 3.0 amps special application, 300mA regulated. End-of-Line Resis- tor: 4.71K ohm, 1/2 watt (P/N 71252 UL listed) for NACs. Refer to Fire-Lite Device Compatibility Document for listed compatible devices. Page 2 of 6— DF-60334:A6 • 2120/2019 Programmable and Trouble Output Relays - TB5: Contact rating: CHG-1 20F: Remote battery charging system for lead-acid batteries 2.0 amps @ 30 VDC (resistive), 0.5 amps @ 30 VAC (resistive), with a rating of 25 to 120 AH. CHG-120F or CHG-75 required for Form-C relays. charging greater than 25 AH batteries. Four-Wire Resettable Smoke Detector Power (24 VDC nominal) - TB3, Terminals 1(+) & 2(—): Maximum ripple voltage: 10 mVRMS. Up to 1.5 amps for powering four-wire smoke detectors. Power-limited circuit. Refer to Fire•Lit- eDevice Compatibility Document for listed compatible devices. Nonresettable Power #1(24 VDC Nominal) —TB3, Terminals 3 (+) & 4 (-): Maximum ripple voltage: 10 mVRMS. Up to 1.5 amps total DC current available from each output. Power-limited circuit. TB3, Terminals 5 (+) & 6 (-): non-resettable power #2. Nonresettable Special Application Power #2 (24 VDC Nominal) - TB3, Terminals 5 (+) & 6 (-): Maximum ripple voltage: 10mVRMS. Total DC current available from each output is up to 1.5 amps. Power-limited circuit, non-supervised. EIA-485 (ACS/ANN) - TB6: Annunciator connector, programmable for type ANN orACS. Terminal 1 (+) and Terminal 2 (-). ElA-485 (TERM) - TB7: Terminal mode annunciator connector, Ter- minal 1 (Out +), 2 (In +), 3 (Out -), 4 (In -). EIA-232 - TB8: PC/printer connector, Terminal 1 (Transmit), 2 (Receive), 3 (DTR), 4 (Ground). Ordering Options MS-9600LS(E): 318-point addressable Fire Alarm Control Panel, one SLC loop. Includes 80-character LCD display, single printed cir- cuit board, and cabinet. MS-9600UDLS(E): 318-point addressable Fire Alarm Control Panel, one SLC loop. Includes 2, 80-character LCD display, single printed circuit board, and cabinet. DACT-UD2: Optional communicator for remote monitoring (standard with MS-9600UDLS). SLC-2LS: Optional expander module, enables second SLC loop. 4XTMF: Optional Transmitter Module provides a supervised output for local energy municipal box transmitter, alarm and trouble reverse polarity. It includes a disable switch and disable trouble. IPDACT-212UD, IPDACT Internet Monitoring Module: Mounts in bottom of enclosure with optional mounting kit (PIN: IPBRKT). Con- nects to primary and secondary DACT telephone output ports for internet communications over customer provided ethernet internet connection. Requires compatible Teldat VisorALARM Central Sta- tion Receiver. Can use DHCP or static IP. (See data sheet DF-60407 or DF-52424 for additional information. IPBRKT: Optional mounting bracket kit consisting of screws and battery shield with standoffs required when mounting the IPDACT in lower enclosure section of FACP. IPSPLT: Optional Y-Adaptor which allows connection of both panel dialer outputs to one cable input to IPDACT (sold separately). ACM-8RF: Optional plug-in relay module provides 8 Form-C 5.0 amp relays. PS-Tools: Programming software for Windows®-based PC com- puter (cable not included). Available for download at www.fire- lite.com. PRT/PK-CABLE: Cable printer/personal computer interlace cable. DP-9692: Optional dress panel for MS-9600LS(E). TR-CE: Optional Trim Ring for semi-flush mounting. BB-55F: Battery box, required to house two 25 AH batteries and one CHG-120F battery charger. For batteries greater than 25 AH, consult factory for housing/mounting arrangements. BB-26: Battery backbox, holds up to two 25 AH batteries. CHG-75: Battery charger for lead-acid batteries with a rating of 25 to 75 AH. CHG-120F or CHG-75 required for charging greater than 25 AH batteries. BAT Series: Batteries, see data sheet DF-52397. PRN Series: UL listed compatible event printer which uses tractor- fed paper. SEISKIT-COMMENC: Seismic kit for the MS-9600UDLS backbox. Includes battery bracket for two 7, 12, or 18 AH batteries. Compatible Addressable Devices All feature a polling LED and rotary switches for addressing. AD355/AD365(-IV): Low-profile, intelligent, "Adapt" multi-sensor detector; B350LP base included. BEAM355: Intelligent beam smoke detector. BEAM355S: Intelligent beam smoke detector with integral sensitiv- ity test. CP355: Addressable low-profile ionization smoke detector. D355PL: Photoelectric low-flow duct smoke detector, 5D355R included. H355/H365: Fast-response, low-profile heat detector. H355R1H365R(-IV): Fast-response, low-profile heat detector with rate-of-rise option. H355HT1H365HT(-IV): Fast-response, low-profile heat detector that activates atlgo" F (88°C). OSl-RI-FL: Addressable long range projected beam smoke detector designed to provide open area protection SD355/5D365(-IV): Addressable low-profile photoelectric smoke detector SD355T/5D365T(-IV): Addressable low-profile photoelectric smoke detector with thermal sensor CDRM-300: Dual relay Monitor Module CMF-300: Addressable Control Module for one Style Y/Z (Class BI A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0" (10.16 cm.) electrical box. Notification Appliance Circuit option requires external 24 VDC to power notification appli- ances. CRF-300: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0 (10.16 cm.) box, surface mount using the SMB500. MDF-300: Dual Monitor Module. Same as MMF-300 except it pro- vides two Style B (Class B) only IDCs MMF-300: Addressable Monitor Module for one zone of normally- open dry-contact initiating devices. Mounts in standard 4.0 (10.16 cm.) box. Includes plastic cover plate and end-of-line resistor. Mod- ule may be configured for either a Style B (Class B) or Style D (Class A) IDC. MMF-301: Miniature version of MMF-300. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. MMF-302: Similar to MMF-300, but may monitor up to 20 conven- tional two-wire detectors. Requires resettable 24 VDC power. Con- sult factory for compatible smoke detectors. BG-I2LX: Addressable manual pull station with interlace module mounted inside 1300: This module isolates the SLC loop from short circuit conditions (required for Style 6 or 7 operation). DF-60334:A6 • 2/20/2019 — Page 3 of 6 Audio Control for ECC-50/100 Emergency Command Center - I IIJJ- SMOKE DETECTORS 5D3551T, SD365/T, CP355 E!A-485 ACS/ANN-BUS ANNUNCIATORS (2-data wires, 2-power wires) ANN-80 E!A-232 INTERFACE ~~* 4_1 PRINTER Optional REVERSE POLARITY! CITY BOX OUTPUT (4XTMF) o IiII 4XTMF Reverse Polarity Module 11111111 8 FORM-C, 5-AMP RELAYS (optional, order ACM-8RF) NACs (Notification Appliance Circuits) BELLS, SIGNALS, STROBES DACT-UD2 for Central Station reporting HEAT DETECTORS H355/R, H365/R U 0 IRM ' DUCT DETECTORS D355PL h" •i E1.. CA 0 S F-3 vU" '11111 00 7 L_ IPDACT Internet Protocol DACT INTELLIGENT BEAM DETECTORS BEAM355, BEAM355S OS I-R I-FL [do c )] —* II III L° ooj MONITOR/CONTROL MMF-300, MDF-300, MMF-302, CMF-300, CRF-300, 300, CDRM-300 Monitor GATEWAY Wireless ko WIRELESS W-GATE Module W-MMF QO Wireless cq - - - - - - Relay Module 60 W-CRF Wireless Photo Detector W-SD355 Wireless Pull Station W-BG1 2LX MINI MONITOR MMF-301 ADDRESSABLE MULTI-MODULES MMF-300-10, MMF-302-6, CMF-300-6, CRF-300-6, ISO-6 - PULL STATION BG-12LX Page 4 of 6 — DF-60334:A6 • 2/20/2019 ISO-6: Six-fault Isolator Module. Mount one or two modules in a BB- 2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F. SMB500: Used to mount all modules except the MMF-301 and M301 MMF-300-10: Ten-input monitor module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F MMF-302-6: Six-zone interface module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F CMF-300-6: Six-circuit supervised control module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F CRF-300-6: Six Form-C relay control module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F W-GATE: SWIFT Wireless Gateway W-DIS-D: LCD user interface for use with the W-GATE wireless gateway and an ANN-80-W Remote Annunciator W-SD355: Intelligent, wireless photo detector W-H355R: Intelligent wireless rate of rise (135°) heat detector W-SD355T: Intelligent wireless photo/heat detector W-I-f355: Intelligent wireless fixed-temperature (135°) heat detector W-MMF: Intelligent wireless monitor module W-CRF: Intelligent wireless relay module W-BGI 2LX: Intelligent wireless pullstation WAV-CRLIWAV-CWL: Intelligent wireless AV bases W-SYNC: Intelligent wireless sync module. W-USB: Wireless USB radio/antenna dongle that plugs into the USB port of a PC running SWIFT Tools SWIFT Tools: Programming and diagnostic utility for the Wireless Gateway and devices. Available for download from flrelite.com. Compatible Annunciators ANN-80(-W): Remote LCD annunciator that mimics the information displayed on the FACP's LCD display. Recommended wire type is unshielded. (Basic model is red; order -W version for white; see DF- 52417). ANN-LED: Annunciator Module provides three LEDs for each zone: Alarm, Trouble and Supervisory. Ships with red enclosure (see OF- 60241). ANN-RLED: Provides alarm (red) indicators for up to 30 input zones or addressable points (see DF-60241). ANN-RLY: Relay Module, which can be mounted inside the cabinet, provides 10 programmable Form-C relays (see OF-52431). ANN-SIPG: Serial/Parallel Printer Gateway module provides a con- nection for a Serial or Parallel printer (see DF-52429). ANN-I/O: I/O Driver Module provides connections to a user supplied graphic annunciator (see DF-52430). ACS-LED Zone Series: LED-type fire annunciators capable of pro- viding up to 99 software zones of annunciation. Available in incre- ments of 16 or 32 points to meet a variety of applications. ACS-LDM Graphic Series: Lamp Driver Module series for use with custom graphic annunciators. LCD-80F Annunciator: 80-character, backlit LCD-type fire annunci- ators capable of displaying English-language text. Up to 32 LCD- 80F annunciators may be connected to the EIA-485 terminal mode serial interface on the MS-9600L5(E) motherboard. NOTE: For more information on Compatible Annunciators for use with the MS-9600LS(E), see the following data sheets (document numbers) ACM-8RF (DF-51555), ACS/ACM Series (DF-52378), LDM Series (OF- 51384), LCD-80F (DF-52185). Wiring Requirements While shielded wire is not required, it is recommended that all SLC wiring be twisted-pair to minimize the effects of electrical interfer- ence. Refer to the panel manual for wiring details. DF-60334:A6 • 2/20/2019 - Page 5 of 6 SYSTEM SPECIFICATIONS System Capacity Intelligent Signaling Line Circuits.....................1 expandable to 2 Intelligent detectors .................................................159 per loop Addressable monitor/control modules .....................159 per loop Programmable software zones................................................99 ANN-BUS devices .....................................................................8 ACS Annunciators ...................................................................32 LCD Annunciators....................................................................32 Electrical Specifications Primary input power: 120 VAC, 50/60 Hz, 3.0 A. 240 VAC, 50 Hz, 1.5A. Battery: 27.6 VDC @ 1.0 A (max). Maximum battery charger capacity: 26 AH. Minimum battery: 12AH. MS-9600LS cabinet holds maximum of two 18 AH batteries. Communication Loop: 24 VDC nominal, supervised and power- limited. Notification Appliance Circuits: terminal block provides connec- tions for four Style Y (Class B) or two Style Z (Class A) NACs. Maximum signaling current per circuit: 3.0 amps special applica- tion, 300mA regulated. End-of-Line Resistor: 4.7 K ohms, ¼ watt (P/N 71252 UL listed) for Style Y (Class B) NAC. Supervised and power-limited. Refer to panel documentation and Fire-Lite Device Compatibility Document for listed compatible devices. Two Programmable Form-C Relays and One Fixed Trouble Form-C Relay: Contact rating: 2.0 A @ 30 VDC (resistive) 0.5 A @ 30 VAC (resistive). Four-wire Resettable Special Application Power (24 VDC nomi- nal): Up to 1.5 A for powering four-wire smoke detectors. Power- Limited, non-supervised. Refer to Fire-Life Device Compatibility Document for listed com- patible devices. Non-resettable Special Application Power #1 (24VDC nominal) TB3, Terminals 3 (+) & 4 (-): Maximum ripple voltage: 10 mVRMS Total DC current available from each output is up to 1.5 A. Power-limited, non-supervised. Non-resettable Special Application Power #2 (24VDC nominal) TB3, Terminals 5 (+) & 6 (-): Maximum ripple voltage: 10 mVRMS Total DC current available from each output is up to 1.5 A. Power-limited, non-supervised. NOTE: Although each Special Application power output can deliver 1.5 A individually, the total power output from these circuits cannot exceed 1.5 A in standby. The total Alarm output for all Special Application power and NA circuits cannot exceed 7A. Cabinet Specifications Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.67" (1.70 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" (42.29 cm.) wide x 5.21" (13.23 cm.) deep. Trim Ring (TR-CE): 22.00" (55.88 cm.) high x 19.65" (49.91 cm.) wide. Shipping Specifications Dimensions: 20.00" (50.80 cm) high, 22.5" (57.15 cm) wide, 8.5" (21.59 cm) deep. Weight: 27.3 lbs (12.38 kg). Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0- 49°C/32 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 - 27°C/60 - 80°F. Agency Listings and Approvals The listings and approvals below apply to the MS-9600LS(E) and MS-9600UDLS(E) control panels. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. ULC: S624 (MS-9600LSC only; see DF-60438) FM APPROVED: to ULANSI 864 CSFM: 7170-0075:217 MEA: 87-08-E IBC 2012, IBC 2009, IBC 2006, IBC 2003, IBC 2000 (Seismic). CBC 2007 (Seismic) NFPA Standards The MS-9600L5(E) and MS-9600UDLS(E) control panels comply with the following NFPA 72 Fire Alarm Systems requirements: - LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervi- sory). - AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTMF). - REMOTE STATION (Automatic, Manual and Waterflow) (Requires 4XTMF where DACT-UD2 is not accepted.) - PROPRIETARY (Automatic, Manual and Waterflow). - CENTRAL STATION (Automatic, Manual and Waterflow, and Sprinkler Supervised). - OT (Other Technologies-PSDN) For use with IPDACT. LiteSpeedTM is a trademark; and FireLite® Alarms and SWIFT® are registered trademarks of Honeywell International Inc. Windows® is a trademark of the Microsoft Corporation. 02019 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I SO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. - • • All specifications are subject to change without notice. MNI1IIIN9 QUALITY SYSTEMS For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. Country of Origin: USA www.firelite.com Page 6 of 6- DF-60334:A6 • 2/20/2019 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0075:0217 Page 1 of 2 CATEGORY: 7165-- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeyweii.com DESIGN: Models MS-9600LS and MS-9600UDLS addressable fire alarm control units. Suitable for local protective, remote, auxiliary, and central station signaling when used with appropriate optional modules and additional separate listed equipment. The panels provide one signaling line circuit for connection of up to 318 total addressable devices (159 detectors and 159 modules); two Class A or four Class B notification appliance circuits; three form C relays are provided that are default programmed for alarm, trouble, and supervisory relay outputs. The MS-9600UDLS come with the DACT-UD2 factory installed. Refer to listee's data sheet for detailed product description and operational considerations. System components: MS-9600L5, MS-9600UDLS Control Unit SLC-2LS Loop Card DACT-UD2 Digital Alarm Communicator Transmitter Modules 4XTMF Transmitter Module LDM-32F Lamp driver Module ACM-8RF Control Relay Module ANN-RLY Remote Relay ANN-80 , ANN-LED, LCD-80F Remote Annunciator ACM-16ATF, ACM-32AF Remote Annunciator AEM-I6ATF, AEM-32AF Remote Annunciator ACC-25/50ZST Audio Command Center (Listing No. 6911-0075:207) RATING: 120 VAC, 50/60 Hz, 3.0 amps INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and FM label. APPROVAL: Listed as fire alarm control unit for use with separately listed compatible initiating and indicating devices. Also suitable for high-rise applications for use with Model ACC-25/50ZST Audio Command Center (Listing No. 6911-0075:207). *Models MS-9600L5 and MS-9600UDLS panels are also suitable for high-rise application for use with Model ECC-50/100 emergency voice evacuation panel (CSFM # 6911-0075:0226). Refer to manufacturer's Installation Manual for details. These control units can generate the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal as required per NFPA 72, 2002 Edition and meet the requirements of *Rev. 01-20-15 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed (\ the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-0075:0217 Page 2 of 2 UL-864, 9th Edition Standard. NOTE: 1. For Fire Alarm Verification Feature (Delay of fire alarm), the maximum Retard/Reset/Restart period must be adjusted to 30 seconds or less. 2. Combined with 7170-0075:220 Rev. 01-20-15 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DF-52417:D • B-90 ANN-80 0 FIreLITeALarms 80-Character Serial LCD Annunciator by Honeywell _77-7 7TiI General - The ANN-80 annunciator is a compact, backlit, 80-character LCD fire annunciator that mimics the Fire Alarm Control Panel (FACP) display. It provides system status indicators for AC Power, Alarm, Trouble, Supervisory, and Alarm Silenced conditions. The ANN-80 and the FACP communicate over a two-wire serial interlace employ- ing the ANN-Bus communication format. Connected devices are powered, via two additional wires, by either the host FACP or a remote UL-listed, filtered power supply. The ANN-80 is red; for white, order ANN-80-W. The ANN-80 displays English-language text of system point informa- tion including device type, zone, independent point alarm, trouble or supervisory status, as well as any custom alpha labels programmed into the control panel. It includes control switches for remote control of critical system functions. (A keyswitch prevents unauthorized operation of the control switches.) Up to eight ANN-80s may be connected to the ANN-Bus of each FACP. No programming is required, which saves time during system commissioning. Features Listed to UL Standard 864, 9th Edition Backlit 80-character LCD display (20 characters x 4 lines) Mimics all display information from the host panel Control switches for System Acknowledge, Signal Silence, Drill, and Reset Control switches can be independently enabled or disabled at the FACP Keyswitch enables/disables control switches and mechanically locks annunciator enclosure Keyswitch can be enabled or disabled at the FACP Enclosure supervised for tamper System status LEDs for AC Power, Alarm, Trouble, Supervisory, and Alarm Silence Local sounder can be enabled or disabled at the FACP ANN-80 connects to the ANN-Bus terminal on the FACP and requires minimal panel programming Displays device type identifiers, individual point alarm, trouble, supervisory, zone, and custom alpha labels Time-and date display field Surface mount directly to wall or to single, double, or 4" square electrical box Semi-flush mount to single, double, or 4" square electrical box. Use ANN-S680K1T for angled view mounting Can be remotely located up to 6,000 feet (1,800 m) from the panel Backlight turns off during AC loss to conserve battery power but will turn back on if an alarm condition occurs May be powered by 24 VDC from the host FACP or by remote power supply (requires 24 VDC) Up to eight ANN-80s can be connected on the ANN-Bus Controls and Indicators AC Power Alarm Trouble Supervisory Alarm Silenced Specifications Operating voltage range: 18 VDC to 28 VDC Current consumption © 24 VDC nominal (filtered and non- resettable): 40 mA maximum Ambient temperature: 32°F to 120°F (0°C to 49°C) Relative humidity: 93% ± 2% RH (non-condensing) at 32°C ± 2°C (90°F ± 3°F) 5.375" (13.65 cm.) high x 6.875" (17.46 cm.) wide x 1.375" (3.49 cm.) deep For use indoors in a dry location All connections are power-limited and supervised The ANN-Bus POWERING THE DEVICES ON THE ANN-BUS FROM AUXIL- IARY POWER SUPPLY The ANN-Bus can be powered by an auxiliary power supply when the maximum number of ANN-Bus devices exceeds the ANN-Bus power requirements. See the FACP manual for more information. ANN-BUS DEVICE ADDRESSING Each ANN-Bus device requires a unique address (ID Number) in order to communicate with the FACP. A maximum of 8 devices can be connected to the FACP ANN-Bus communication circuit. See the FACP manual for more information. WIRE REQUIREMENTS: COMMUNICATIONS CIRCUIT The ANN-80 connects to the FACP ANN-Bus communications cir- cuit. To determine the type of wire and the maximum wiring distance that can be used with FACP ANN-Bus accessory modules, it is nec- essary to calculate the total worst case current draw for all modules on a single 4-conductor bus. The total worst case current draw is calculated by adding the individual worst case currents for each module. NOTE: For total worst case current draw on a single ANN-Bus refer to appropriate FACP manual. DF-52417:D • 3/15/2018 - Page 1 of 2 WIRE REQUIREMENTS: POWER CIRCUIT 14 to 18 AWG (0.75- 2.08 mm2) wire for 24 VDC power circuit is acceptable. Power wire distance limitation is set by 1.2 volt maxi- mum line drop form source to end of circuit. All connections are power-limited and supervised. A maximum of eight ANN-80 modules may be connected to this circuit. Ordering Options ANN-80: Red 80 character LCD Annunciator. ANN-80-W: White, 80 character LCD Annunciator. ANN-SB80KIT-R: Red surface mount backbox with angled wedge. ANN-SB80KIT-W: White surface mount backbox with angled wedge. Agency Listings and Approvals The listings and approvals below apply to the ANN-80. In some cases, certain modules may not be listed by certain approval agen- cies, or listing may be in process. Consult factory for latest listing status. UL: S2424 FM approved CSFM: 7120-0075:0211 MEA: 442-06-E Fire-Lite® Alarms is a registered trademark of Honeywell International Inc. 02018 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. ISO 9001 We cannot cover all specific applications or anticipate all requirements. 93=1= 1All specifications are subject to change without notice. :b UU IlN1 MNWIg1IIIN QUALITY SYSTEMS For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. Country of Origin: USA www.flrelite.com Page 2 of 2— DF-52417:1) • 3/15/2018 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7120-0075:0211 Page 1 of 1 CATEGORY: 7120--ANNUNCIATORS LISTEE: FIRE-LITE ALARMS lNC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sissonhoneywell.com DESIGN: Model ANN-80 and *ANN80w remote fire annunciators. Unit is a 80-character, supervised backlit LCD fire annunciator. Communication between the control panel and the annunciator is accomplished over a two-wire serial interface employing the ANN-BUS protocol. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listees name, product number, electrical rating and UL label. APPROVAL: Listed as an annunciators for use separately listed compatible fire alarm control units. Refer to Manufacturers Installation Manual for details. *Rev. 04-28-08 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed f\ the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct v' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division IThlJfaI1 Teld makes adöting ell la easy with a sufe lnterne a ,' The straightforward web interface gilhija user authorization and rovi es total accountJaemien 0 QL L!stedIJPa[dlar alarm commuticato. &T@Fu—ardrG~5lIula -e ice IiU7d GIlllar 1ce1WroyJles lTiajit cocaI[or CogmQnication Genter is UL corDp and pqvides searnLe~s connect ivity between the alarrn Pnejhe elFd family of cellular servicelanclikleigua quest! ojs. AMETEK ó COMMERCIAL FIRE PRODUCT FEATURES I- Certified for use on the AT&T LTE network for sunset-free installations. I- Meets UL 864 requirements for sole, primary or backup path communications. - Minimizes false alarms by providing dual paths for self-tests. I- Falls back to 3G/4G if an LIE network is not available, for extended network coverage. The Telguard TG-7FS LIE-A is the ideal cellular alarm communications solution for commercial fire systems. The TG-7FS LTE-A transmits alarm signals from the fire panel over the digital cellular network to the designated monitoring station. Compliant with the 2019 and earlier editions of NFPA 72, the TG-7FS LTE-A can serve as the sole communication path for the fire alarm system. It replaces all of the landlines currently dedicated to the master control unit. On average, cellular monitoring costs the end user significantly less than a dedicated landline. For each landline replaced with a TG-7FS LIE-A, the monthly communications bill decreases. By being able to signal failures to the central station within sixty minutes of an outage, the TG-7FS LTE-A can be installed as the sole path for commercial fire installations. For existing installations, all landlines can be swapped for a single TG-7FS LTE-A because of the new five or sixty minute supervision modes. The TG-7FS LIE-A can also be installed as a backup path and upgraded to sole path at a later date. CELLULAR ALARM COMMUNICATOR FOR LTE NETWORKS vancejlility ëtures the bility to utilize multiple cellular technologies to in rese aVjailabilitVUduce fal e las. ic Alit' atiItts wifh cent'Fl S ation ribtatiensuiie tië cell'lar ystem is peca Availa to relay ouf' for Iiing the alarm cool panel en%a troule condition TG-7FS LTE-A TELGUARD Ugower TfiiWiit Power: in Power Consumption: 40\ ('S) 160mA (jEansmis9in)1iThTiii9'k supervisioenIed [Rrdi5IransceLF1 LTiii,jEBand s:2,4&11 3G ands:2&5. Antenna: 9" diPoleJBJIn 12Lf all ar)JL.e.Csal mounting racket. Gi5, 22!2i!2Jjd68 conjpiiant. TGFS L.TE'p111T5AWfl3i Shipping eight: 811 s. Operating Environment: 0°C t'5OC; up 0 950. (opfljcoieflsiQg [SJtF Ordreporting. Automati self-test (5 o 6. minute, and d3iI). L ng, re m oc i etal enclosure. TWb prograjn6ie a ueoy trip outputs. Alarm f VrrLa2 siipppr for S1A2 Gontact ID, pulse 04 modem lie, & Via , DMP. o-T-61'e-61tone line monitor ilt-in with Stagçla. LJe Sec y. LW4 TELGUARD TG-7FS LTE-A CELLULAR ALARM COMMUNICATOR FOR LTE NETWORKS AMETEK (Sit) _ 1~ _a -1 ... r~ C* et-1, C,-nicafl,n7)_ landline (eptlo',,l) Telguard technology allows full data reporting for unlimited point-to-point signal details and maximum transmitting power for superior in-building penetration. Telguard products are easy to install, economical, and UL Listed. Accessories ACD 12, ACD 35, ACD 50, ACD 100: 12/35/50/100 feet of low loss, high performance cable. HGD-O: High gain directional antenna. EXD-O: External antenna. UL Listings Commercial Fire 864 • control units & accessories for fire alarm systems Commercial Burglary 365 • Police Station connected burglar alarm units and systems 1610 • Central station burglar alarm units; Line security servcies Residential 985 • Household fire warning systems 1023 • Household burglar alarm systems ULC Listings S545 • Canadian household fire warning systems S304 • Canadian commercial burglary alarm systems S559 • Equipment for fire signal receiving centres and systems C0123 • Canadian household burglary alarm systems For the most current product specifications and UL Listings visit www.Teiguard.com. SECURITY SIGNALING SECURITY - :. C@U NV NFPA '/Il\ Executive Strategic Partner Connected LISTED INTERNATIONAL Gold by AT&T Telguard, a Division of Telular Corporation • 3225 Cumberland Blvd SE • Suite 300 • Atlanta, GA 30339 • USA 800.229.2326 1 telguard.com Copyright ©2019 Telguard, a Business Unit of AMETEK, Inc. • All Rights Reserved CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1402:0500 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: TELULAR CORP.3225 Cumberland Blvd, Suite 300, Atlanta, GA 30339 Contact: Raj Kosaraju (678) 264-2012 Fax (678) 264-2062 Email: rkosaraju@telular.com DESIGN: Model TG7LVO02, TG7LVA02, TG7LVF02, and TG7 KIT digital cellular communicators, digital cellular radio alarm transmission device used to provide a primary (sole or with a back-up) or back-up transmission path using cellular for control communicators. Refer to listee's printed data sheet for additional detailed product description and operational considerations RATING: 120 Vac INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as digital cellular radio alarm transmission device. Refer to listee's Installation Instruction Manual for details. NOTE: Burglary and other non-fire functions were not examined. 11-02-2018 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DF-52310:A2 • D-050 FCPS-24FS8 0_A 0A_I.i1 D,ii... CNo I (a Fire-LITUALarms by Honeywell Power Supplies/Accessories General The Fire-Lite FCPS-24FS8(CIE) is a compact, cost-effec- tive, 8-amp remote power supplies with battery charger. The FCPS-24FS8C/E) may be connected to any 12 or 24 volt fire alarm control panel (FACP) or may stand-alone. Primary appli- cations include notification appliance (bell) circuit (NAG) expansion (to support ADA requirements and NAG synchroni- zation) or auxiliary power to support 24 volt system accesso- ries. The FGPS provides regulated and filtered 24 VDG power to four notification appliance circuits configured as either two Glass B (Style Y) and Glass A (Style Z, with ZNAG-4 option module) or four class B only. Alternately, the four outputs may be configured as any combination of resettable/non-resettable power outputs (optimal for powering four-wire smoke detec- tors. The FFGPS-24F58(G/E) also contains a battery charger capable of charging up to 18.0 Amp hour batteries. FGPS- 24FS8G/E) is ULG-listed. NOTE: Unless otherwise specified, the term FCPS-24FS8 used in this document refers to the standard FCPS-24FS8, FCPS- 24FS8C, FCPS-24FS8E Features UL-Listed Notification Appliance Circuit (NAG) synchroniza- tion using System Sensor, Wheelock, or Gentex "Gom- mander2" appliances. Operates as a "sync-follower" or as a sync-generator" (default). See note on page 2. Contains two fully-isolated input/control circuits - triggered from FAGP NAG (NAG expander mode) or jumped perma- nently "ON" (stand-alone mode). Two Glass B (Style Y) or Glass A (Style Z, with ZNAG-4 module) NAGs (circuits 1 & 3) 8-amp full load output, with 3 amps maximum/circuit, in NAG expander mode (UL 864). 6-amp continuous output in stand-alone mode (UL 1481). Compatible with coded inputs; signals passed through. Optional power-supervision relay (EOLR-1). In stand-alone mode, output power circuits may be config- ured as: resettable, (reset line from FAGP required), non-resettable, or a mix of two and two. Fully regulated and filtered power output - optimal for pow- ering four-wire smoke detectors, annunciators, and other system peripherals requiring regulated/filtered power. Power-limiting technology meets UL power-limiting require- ments. Form-G normally-closed trouble relay. Fully supervised power supply, battery, and NAGs. Selectable earth fault detection. AG trouble report selectable for immediate 2-hour delay. Works with virtually any UL 864 fire alarm control which uti- lizes an industry-standard reverse-polarity notification cir- cuit (including unfiltered and unregulated bell power). Requires input trigger voltage of 9 - 32 VDG. Self-contained in compact, locking cabinet - 15"H x 14.5W x 2.75"D (cm: 38.1 H x 36.83W x 6.985D). Includes integral battery charger capable of charging up to 18 AH batteries. Cabinet capable of housing 7.0 AH batter- ies. Battery charger may be disabled via DIP switch for applica- tions requiring larger batteries. Fixed, clamp-type terminal blocks accommodate up to 12 AWG (3.1mm2) wire. Specifications Primary (AC) Power: FCPS-24FS8: 120 VAC, 60 Hz, 3.2A maximum. FGPS-24FS8/E: 240 VAC, 50 Hz, 1.6A maximum. Wire Size: minimum #14 AWG (2.0mm2) with 600 V insula- tion. Control Input Circuit: Trigger Input Voltage: 9 to 32 VDG. Trigger Current: 2.0 mA (16-32 V); Per Input: 1.0 mA (9 - 16V). Trouble Contact Rating: 5 A at 24 VDG. Auxiliary Power Output: Specific application power 500 mA maximum. Output Circuits: +24 VDG filtered, regulated. 3.0 A maximum for any one circuit. Total continuous current for all outputs (stand-alone mode): - FCPS-24FS8: 6.0 A maximum. Total short-term current for all outputs (NAG expander mode): - FCPS-24FS8: 8.0 A maximum. DF-52310:A2 • 5/17/13 - Page 1 of 4 Secondary Power (Battery) Charging Circuit: Supports lead-acid batteries only. Float-charge voltage: 27.6 VDC. Maximum current charge: 250 mA. Maximum battery capacity: 7.0 AH. Applications Example 1: Expand notification appliance power an additional 8.0 A. Use up to four Class B (Style Y) outputs or four Class A (Style Z) outputs (using ZNAC-4). For example, the FACP noti- fication appliance circuits will activate the FCPS when reverse- polarity activation occurs. Trouble conditions on the FCPS are sensed by the FACP through the notification appliance circuit. Example 2: Use the FCPS to expand auxiliary regulated 24- volt system power up to 6.0 A. Both resettable and non-reset- table power options are available. Resettable outputs are cre- ated by connecting the resettable output from the FACP to one or both of the FCPS inputs. Example 3: Use addressable control modules to activate the FCPS instead of activating it through the FACP notification appliance circuits. This typically allows for mounting the FCPS at greater distances* away from the FACP while expanding system architecture in various applications. For example, an addressable control module is used to acti- vate the FCPS, and an addressable monitor module is used to sense FCPS trouble conditions. Local auxiliary power output from the FCPS provides power to the addressable control module. NOTE: Addressable FACPs are capable of locating control and monitor modules at distances of up to 10,000 feet (3,046 meters). Sync Follower/Generator Note In some installations, it is necessary to synchronize the flash timing of all strobes in the system for ADA compliance. Strobes accomplish this by monitoring very short timing pulses on the NAC power which are created by the FACP. When installed at the end of a NAG wire run, the FCPS-24F58 can track (i.e. follow") the strobe synchronization timing pulses on the existing NAG wire run. This maintains the overall system flash timing of the additional strobes attaches to the FCPS. When the FCPS-24F58 is configured (via DIP switch settings) as a "sync follower," the FCPS's NAC outputs track the strobe synchronization pulses present at the FCPS's sync input ter- minal. The pulses originate from an upstream FACP or other power supply. When the FCPS-24F58 is configured (via DIP switch settings) as a "sync generator," the FCPS's sync input terminals are not used. Rather, the FCPS is the originator of the strobe synchro- nization pulses on the FCPS's NAC outputs. In "sync genera- tor" mode, the sync type (System Sensor, Wheelock, or Gentex) is selectable via DIP switch settings. Standards and Codes The FCPS-24F58 complies with the following standards: NFPA 72 National Fire Alarm Code. UL 864 Standard for Control Units for Fire Alarm Systems (NAG expander mode). UL 1481 Power Supplies for Fire Alarm Systems. Page 2 of 4— DF-52310:A2 • 5/17/13 Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S2424 ULC Listed: S2424 CSFM Approved: 7315-0075:206 MEA:219-02E Ordering Information FCPS-24FS8: 6.0 A, 120 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5W x 2.75D [cm: 38.1H x 36.83W x 6.985D]), and installation instructions. FCPS-24FS8 is ULC-listed. FCPS-24FS8E: 6.0 A, 240 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5W x 2.75"D [cm: 38.1H x 36.83W x 6.985D]), and installation instructions. ZNAC-4: Glass A (Style Y) NAG option module. EOLR-1: 12/24 VDG end-of-line relay for monitoring four-wire smoke detector power. BAT-1270: Battery, 12-volt, 7.0 AH (two required). PS-1270: Battery, 12-volt, 7.0 AH (two required). 90286: Optional module mounting kit, is required to install an addressable module on the power supply main circuit board. NOTE: All NAC outputs can be converted to Style Z with Style Y NAC or ZNAC-4 option module. FCPS Door Holder Trouble Power Style Y NAC Style Y NAC Style Y NAC Contact Output #4 Output #3 Output #2 Output #1 Output 24VDC Specific Application Power NAC Control Input #2 (from FACP) NAC Control Input #1 (from FACP) Sync Input AC POWE Battery Charger Simplified Block Diagram DF-52310:A2 • 5/17/13 - Page 3 of 4 0 0 = G) .s07 00 00 .ca, o q 't,. 0 0 <t e N - -, w E 0 .. N (3 NV•O LL F ° ° 1I_ 0 H iF 00 ZZ F[FF 00 zz 5-5 +I 00 c,J Co EEiE1 :4 a Z Z Z !t E2 CL it a -a. i-U) 5 iF C. 5 0 a. E > .5 E .5 £ (3 :z . • C C C C = 3 0 0 3 3 0 0 0. 0. Lij'-.O < < 0 0 0 0 0 0 U) U) i- i + i + + + I + e°I Ca 1') N 0 5 EL .U) .2 X 0a E:1 MEW iii U U 558 I 1 0 0 0001 ro 0 0001 0 .-iFI) 101 L_J ii. co — E:OEEEEJJ e. Board Layout System Sensor® and FireLite® Alarms are registered trademarks of Honeywell International Inc. ©2013 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. MA1dIF*1UIN All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 4 of 4— DF-52310:A2 • 5/17/13 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7315-0075:0206 Page 1 of 1 CATEGORY: 7315-- POWER UNITS LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sissonhoneywell.com DESIGN: Models FCPS-24FS6 and FCPS-24FS8 are power limited power supply/battery chargers used for supervision and expanded power driving capability of up to four Notification Appliance Circuits (FACP Fire Circuits, Signaling Devices) or resettable/non resettable outputs. Model ZNAC-4 Class A converter. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120 VAC, 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product designation, electrical rating and UL label. APPROVAL: Listed as a Power Supply/Battery Charger for use with separately listed compatible fire alarm control units. NOTE: *Rev. 05-06-05JW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division SD365(A) Series Addressable Photoelectric Detectors DF-61 O1O:A 8 FIreLITeALarms by Honeywell The Fire-Lite SD365(A), SD365T(A), and SD365R(A) Series addressable plug-in photoelectric smoke detectors are designed for both performance and aesthetics. A new modern, sleek, contempo- rary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. Exclusively for use with Fire-Lite's addressable fire alarm control panels, the SD365(A) Series point ID capability allows each detec- tor's address to be set with rotary, decimal address switches, provid- ing exact detector location for emergency personnel to quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible sensor indication. The 5D365(A) Series also offers 135°F (57°C) fixed temperature thermal sensing on the 5D365T(A) and a remote test capable detec- tor on the SD365R(A) for use with DNR(A)/DNRW duct smoke detector housings. Features SLC LOOP Two-wire loop connection. Unit uses base for wiring. ADDRESSING Addressable by device. Rotary, decimal addressing: Please refer to the Fire-Lite panel manuals for device capacity. ARCHITECTURE New modern profile for improved aesthetics. Unique single-source design to respond quickly and dependably to a broad range of fires. Integral communications and built-in type identification. Built-in tamper-resistant feature. Removable cover and insect-resistant screen for simple field cleaning. OPERATION Designed to meet UL 268 7th Edition. Factory preset at 1.5% nominal sensitivity for panel alarm thresh- old level. Visible LED "blinks" when the unit is addressed (communicating with the fire panel) and latches on in alarm. Low standby current. MECHANICALS Sealed against back pressure. Mounts to: single-gang box, 3.5' (8.89 cm) or 4.0' (10.16 cm) octagonal box, or 4.0' (10.16 cm) square electrical box (with or without a mud ring - not included). OPTIONS Remote LED output connection, RA100Z. 5D365 Installation 5D365(A) series plug-in detectors use a detachable mounting base to simplify installation, service and maintenance. Mount base (all base types) on an electrical backbox which is at least 1.5' (3.81 cm) deep. For a chart of compatible junction boxes, see DF-60059. NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring "T-taps" or branches are permitted for Style 4 (Class B) wiring. SD365R(A) mounts in a D355PL(A) or DNR(A) /DNRW duct detector housing. Operation Each SD365(A) Series detector uses one possible addresses on the Fire-lite Signaling Line Circuit (SLC). It responds to regular polls from the system and reports its type and status. Detector Sensitivity Test Each detector can have its sensitivity tested (required per NFPA 72, Chapter 14 on Inspection, Testing and Maintenance) when installed/ connected to an ES-50X or ES-200X addressable fire alarm control panel. The results of the sensitivity test can be printed off the for record keeping. Specification Voltage range: 15-32 VDC (peak). Standby current: 200 pA © 24 VDC. Max current: 4.5 mA © 24 VDC (latched ON"). Air velocity: 4,000 ft/mm. (20 rn/sec.) maximum. Sensitivity: UL Applications: 0.5% to 4.0% per foot obscuration Size: 2.0' (5.3 cm) high; base determines diameter. - B300-6: 6.1' (15.6 cm) diameter. - B501: 4' (10.2 cm) diameter. For a complete list of detector bases see DN-60981. Shipping weight: 3.4 oz. (95 g). DF-61 O1O:A • 4/2/18 - Page 1 of 3 Operating temperature range: SD365(A): 000 to 50°C (32°F to 122°F); SD365T(A): 0°C to 38°C (32°F to 100°F). SD365R(A): installed in a DNR(A)/DNRW -20°C to 70°C (-4°F to 158°F). Relative humidity: 10%-93%, non-condensing. Listings Listings and approvals below apply to the SD365 Series detectors. In some cases, certain detectors may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. ULJULC Listed: S1059 CSFM: 7272-0075-0502 FM Approved Product Line Information NOTE: Detectors must be mounted to one of the Intelligent Bases listed below. NOTE: 'IV" suffix indicates LiteSpeedo and CLIP device. NOTE: "A" suffix indicates Canadian version. SD365(A): White, Addressable photoelectric detector; B300-6 base included. LiteSpeed only. SD365(A)-IV: Ivory, Addressable photoelectric detector; B300-6 base included. SD365T(A): White, Same as 5D365 but with thermal element; B300-6 base included. LiteSpeed only. SD365T(A)-IV: Ivory, Same as 5D365 but with thermal element; B300-6 base included. SD365R(A): White, Remote test capable addressable photoelectric detector for use with DNR(A)/DNRW. LiteSpeed only. SD365R(A)-IV: Ivory, Remote test capable addressable photoelec- tric detector; for use with DNR(A)/DNRW. INTELLIGENT BASES NOTE: For details on intelligent bases, see DN-60981. B300-6: White, 6" base, standard flanged low-profile mounting base. (CSFM: 7300-1653:0109 Pending) B300-6-IV: Ivory,6" base, standard flanged low-profile mounting base. (CSFM: 7300-1653:0109 Pending) B300A-6: Same as B300-6, ULC listed. B300A-6-IV: Ivory, 6" standard flanged low-profile mounting base, ULC listed. B300-6-BP: Bulk pack of B300-6, package contains 10 B501-WHITE: White, 4" standard European flangeless mounting base. UL/ULC listed. (CSFM: 7300-1653:0109 Pending) B501-BL: Black, 4" standard European flangeless mounting base. ULIULC listed. (CSFM: 7300-1653:0109 Pending) B224B1-IV: Ivory isolator detector base. (CSFM: 7300-1653:0216 Pending) B224B1A-WH: White, isolator detector base, ULC listing. B224B1A-IV: Ivory isolator detector base, ULC listing. B200S-WH: White, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. (CSFM: 7300-1653:0213 Pending) B200S-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. (CSFM: 7300-1653:0213 Pending) B200SA-WH: Same as B200S-WH, ULC listing. B200SA-IV: Same as B200S-IV, ULC listing. B200SCOA-WH: White, Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with CO Series detector applications. B200SCOA-IV: Ivory Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with CO Series detector applications, ULC listing. B200S-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz .i-/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0238 Pending) B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +1- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0238 Pending) B200SR-WH: White, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM: 7300-1653:0213 Pending) B200SR-IV: Ivory, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM: 7300-1653:0213 Pending) B200SRA-WH: Same as B200SR-WH with, ULC listing. B200SRA-IV: Same as B200SR-IV in Ivory color, ULC listing. B200SR-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM: 7300-1653:0238 Pending) B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM: 7300-1653:0238 Pending) MOUNTING KITS AND ACCESSORIES TR300: White, replacement flange for B21OLP(A) base. B501-IV: Ivory color, 4" standard European flangeless mounting TR300-IV: Ivory, replacement flange for B21OLP(A) base. base. UL/ULC listed. (CSCAA- RA100Z(A): Remote LED annunciator. 3 — 32 VDC. Mounts to a B501 -WHITE-BP: Bulk pack of B501 -WHITE contains 10. U.S. single-gang electrical box. For use with B501(A) and B300- B224RB-WH: White, relay base. (CSFM: 7300-1653:0216 Pending) 6(A). B224RB-IV: Ivory, relay base. (CSFM: 7300-1653:0216 Pending) M02-04-00: Test magnet. B224RBA-WH: White, relay base, ULC listing. M02-09-00: Test magnet with telescoping handle. B224RBA-IV: Ivory, relay base, ULC listing. CK300: Color Kit (includes cover and trim ring), white, 10-pack. B224B1-WH: White, isolator detector base. (CSFM: 7300- CK300-IV: Color Kit (includes cover and trim ring), ivory, 10-pack. 1653:0216 Pending) CK300-BL: Color Kit (includes cover and trim ring), black, 10-pack. DF-61 01O:A • 4/4/18 — Page 2 of 3 FireLlte® Alarms is a registered trademark of Honeywell International Inc. ©2018 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. S O9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. I ____________________ All specifications are subject to change without notice. I U WrffM & MANUMC1UIlN QUALITY SYSTEMS For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 3 of 3— DF-61010:A • 4/4/18 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0075:0502 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sissonhoneywell.com DESIGN: Models S0365, 5D365R and 5D365T analog addressable, photoelectric smoke detectors for open area and duct installations. Model 5D365T has a complementary heat detector. All models are similarl except for population/depopulation of components on the Printed Wiring Board for the intended features. All above models may be followed by two digit Suffix indicating the color of the detector enclosure: no suffix for white, -IV for ivory, -BL for black. Refer to listees Installation and Maintenance Instruction for additional detailed product description and operational considerations. RATING: 24VDC. INSTALLATION: In accordance with listees printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as photoelectric smoke detectors. Detectors are for use with separately listed System Sensor base Models B200S and B200SR (CSFM Listing 7300-1653:0213), B200S-LF and B200SR-LF (CSFM Listing 7300-1653:0238), B300-6 and B300-6-IS bases (CSFM Listing 7300-1653:0109), System Sensor duct detector housings Models DNR and DNRW (CSFM listing 3240-1653:0209), Fire-Lite duct detector housing Model D355PL (CSFM listing 3240-0075:0221) and separately listed compatible fire alarm control units. Refer to manufacturers Installation Manual for details. XLF: 7272-0028:0503 02-01-18 gt 61 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division H365(A) Series Addressable Thermal Detectors 8 FIreLITeALarms by Honeywell General The Fire-Lite H365(A), H365R(A), and H365HT(A) Series address- able plug-in thermal detectors are designed for both performance and aesthetics. A new modern, sleek, contemporary design and advanced thermal technologies make the H365(A) Series ideal for both system operation and building design. Exclusively for use with Fire-Lite's addressable fire alarm control panels, the H365(A) Series point ID capability allows each detector's address to be set with rotary, decimal address switches, providing exact detector location for emergency personnel to quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible sensor indication. The H365(A) Series includes fixed temperature, rate-of-rise and high heat fixed temperature detectors that provide effective, intelligent property protection for a variety of applications. Features SLC Loop: Two-wire SLC loop connection. Unit uses base for wiring. ADDRESSING: Addressable by device. Rotary, decimal addressing. Please refer to the Fire-Life panel manuals for device capacity. ARCHITECTURE: Sleek, low-profile, stylish design. State-of-the-art thermistor technology for fast response. Integral communications and built-in device-type identification Built-in tamper resistant feature. Built-in functional test switch activated by external magnet. OPERATION: Fixed temperature model (H365(A)) factory preset to 135°F (57°C). Rate-of-rise model (H365R(A)), 15°F (8.3°C) per minute. High-temperature model (H365HT(A)) factory preset to 190°F (88°C). 3600-field viewing angle of the visual alarm indicators (two bicolor LEDs). LEDs blink red in Normal condition and turn on steady red in Alarm. • Visible LEDs 'blink" every time the unit is addressed. MECHANICALS: Sealed against back pressure. SEMS screws for wiring of the separate base. Designed for direct-surface or electrical-box mounting. Plugs into separate base for ease of installation and maintenance. Separate base allows interchange of photoelectric, ionization and thermal sensors. OTHER SYSTEM FEATURES: Remote test feature from the panel. Walk test with address display. Low standby current. H365 Options: Remote LED output connection to optional RA100Z remote LED annunciator. Installation H365 Series plug-in intelligent thermal detectors use a detachable base to simplify installation, service and maintenance. Installation instructions are shipped with each detector. Mount base (all base types) on an electrical backbox which is at least 1.5' (3.81 cm) deep. For a chart of compatible junction boxes, see DF-60059. NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring '7-taps" or branches are per- mitted for Style 4 (Class GB") wiring only. Applications Use thermal detectors for protection of property. Construction These detectors are constructed of fire-resistant plastic. The H365 Series plug-in intelligent thermal detectors are designed to commer- cial standards and offer an attractive appearance. Operation Each H365 Series detector uses one of 159 (panel dependent) pos- sible addresses on the Fire-Lite Signaling Line Circuit (SLC). It responds to regular polls from the control panel and reports its type and the status. If it receives a test command from the panel (or a local magnet test), it stimulates its electronics and reports an alarm. It blinks its LEDs when polled and turns the LEDs on when com- manded by the panel. The H365 Series offers features and perfor- mance that represent the latest in thermal detector technology. DF-61 01l A • 4/23/18 - Page 1 of 3 Specifications Size: 2.0' (5.3 cm) high; base determines diameter. — B300-6: 6.1' (15.6 cm) diameter. — B501: 4' (10.2 cm) diameter. For a complete list of detector bases see DF-60983 Shipping weight: 3.4 oz. (95 g). Operating temperature range: H365, H365R Series: —20°C to 38°C (-4°F to 100°F); H365H: —20°C to 66°C (-4°F to 1500F). Detector spacing: UL approved for 50 ft. (15.24 m) center to center. FM approved for 25 x 25 ft. (7.62 x 7.62 m) spacing. Relative humidity: 10% — 93% noncondensing. Mounting: B300-6(A) flanged base, included. See "Product Line Information: Intelligent Bases," if using a dif- ferent base. Fixed-temperature setpoint: 135°F (57°C) for the H365 and H365R; 190°F (88°C) for the H365HT. Rate-of-rise detection: responds to greater than 15°F (8.3°C) per minute. ELECTRICAL SPECIFICATIONS Voltage range: 15 - 32 volts DC peak. Standby current (max. avg.): 200uA @ 24 VDC (one communica- tion every 5 seconds with LED enabled). Max current: 4.5 mA @ 24 VDC (ON"). Listings and Approvals Listings and approvals below apply to the H365(A) Series detectors. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. ULIULC Listing: S2101 FM Approved CSFM: 7272-0075-0501 Product Line Information NOTE: 'lV" suffix indicates CLIP and LiteSpeed device. NOTE: "A" suffix indicates Canadian version. H365(A): White, low-profile intelligent 135°F fixed thermal sensor, B300-6 base included. LiteSpeed only. H365(A)-IV: Ivory, low-profile intelligent 135°F fixed thermal sensor, B300-6 base included. H365R(A): White, low-profile intelligent rate-of-rise thermal sensor, B300-6 base included. LiteSpeed only. H365R(A)-IV: Ivory, low-profile intelligent rate-of-rise fixed thermal sensor, B300-6 base included. H365HT(A): White, low-profile intelligent 190°F fixed thermal sensor, B300-6 base included. LiteSpeed only. H365HT(A)-IV: Ivory, low-profile intelligent 190°F thermal sensor, B300-6 base included. INTELLIGENT BASES NOTE: For details on intelligent bases, see DF-60059. B300-6: White, 6" base, standard flanged low-profile mounting base. (CSFM: 7300-1653:0109) B300-6-IV: lvory,6" base, standard flanged low-profile mounting base. (CSFM: 7300-1653.0109) B300A-6: Same as B300-6, ULC listed. B300A-6-IV: Ivory, 6" standard flanged low-profile mounting base, ULC listed. B300-6-BP: Bulk pack of B300-6, package contains 10 B501-WHITE: White, 4" standard European flangeless mounting base. UUULC listed. (CSFM: 7300-1653:0109) B501-BL: Black, 4" standard European flangeless mounting base. UL/ULC listed. (CSFM: 7300-1653:0109) B501-IV: Ivory color, 4" standard European flangeless mounting base. ULIULC listed. (CSFM: 7300-1653:0109) B501-WHITE-BP: Bulk pack of B501-WHITE contains 10. B224RB-WH: White, relay base. (CSFM: 7300-1653:0216) B224RB-IV: Ivory, relay base. (CSFM: 7300-1653:0216) B224RBA-WH: White, relay base, ULC listing. B224RBA-IV: Ivory, relay base, ULC listing. B224B1-WH: White, isolator detector base. (CSFM: 7300- 1653:0216) B224B1-IV: Ivory isolator detector base. (CSFM: 7300-1653:0216) B224B1A-WH: White, isolator detector base, ULC listing. B224B1A-IV: Ivory isolator detector base, ULC listing. B200S-WH: White, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. (CSFM: 7300-1653:0213) B200S-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. (CSFM: 7300-1653:0213) B200SA-WH: Same as B200S-WH, ULC listing. B200SA-IV: Same as B2005-IV, ULC listing. B200SCOA-WH: White, Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with CO Series detector applications. B200SCOA-IV: Ivory Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with CO Series detector applications, ULC listing. B200S-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0238) B2005-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +1- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0238) 8200SR-WH: White, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM: 7300-1653:0213) B200SR-IV: Ivory, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM: 7300-1653:0213) B200SRA-WH: Same as B200SR-WH with, ULC listing. B200SRA-IV: Same as B200SR-IV in Ivory color, ULC listing. B200SR-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM: 7300-1653:0238) B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz -i-/- 10% with a square wave or its equivalent; designed to meet the DF-6101 1:A • 4/23/18 —Page 2 of 3 NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM: 7300-1653:0238) MOUNTING KITS AND ACCESSORIES TR300: White, replacement flange for B21OLP(A) base. TR300-IV: Ivory, replacement flange for B21OLP(A) base. RA100Z(A): Remote LED annunciator. 3 - 32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501(A) and B300- 6(A). M02-04-00: Test magnet. M02-09-00: Test magnet with telescoping handle. CK300: Color Kit (includes cover and trim ring), white, 10-pack. CK300-IV: Color Kit (includes cover and trim ring), ivory, 10-pack. CK300-BL: Color Kit (includes cover and trim ring), black, 10-pack. Fire-Lite® Alarms is a registered trademark of Honeywell International Inc. ©2018 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I SO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ____________________ All specifications are subject to change without notice. I I .1 & MAN MCIUIIAN QUALITY SYSTEMS For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 3 of 3— DF-61 01l :A • 4/23/18 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL _____ FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7270-0075:0501 Page 1 of 1 CATEGORY: 7270 -- HEAT DETECTOR LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Models H365, H365HT (fixed temperature) and H365R (fixed temperature with Rate-of-Rise) electronic heat detectors. Suffix -IV for ivory color and -BL for black color. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Model H365 (fixed temperature): 135°F. Model H365HT (fixed temperature): 190°F. Model H365R (fixed temperature with rate of rise):135°F. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical ratings, and UL label. APPROVAL: Listed as heat detectors for use with Notifier base B71OLP (CSFM#7300-0028:173); System Sensor bases B510, B21OLP, B300-6, B300-6-IS (CSFM#7300-1653:0109); 13224131, B224RB (CSFM#7300-1653:0126); B200S, B200SR (CSFM#7300-1653:0213); B2005-LF, B200SR-LF (CSFM#7300-1653:238); and separately listed compatible fire alarm control units. Refer to listee's Installation Instructions Manual for details. XLF: 7270-0028:0502 02-01-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DF-60430:C2 • E-650 D355PL(A)/DNRW InnovairFiex Intelligent Non-Relay Photoelectric Duct Smoke Detector 8 Fire iearms by Honeywell Intelligent Addressable Device The Fire•Lite InnovairFiex® D355PL(A) intelligent non-relay photoelectric duct smoke detector and DNRW watertight non- relay photoelectric duct smoke detector feature a pivoting housing that fits both square and rectangular footprints capa- ble of mounting to a round or rectangular duct. DNRW duct smoke detector, with its NEMA-4 rating, is listed as a watertight, UV resistant enclosure providing protection against falling dirt, rain, and windblown dust, splashing and hose directed water, allowing operators to use the detector in the most extreme environments. These units sense smoke in the most challenging conditions, operating in airflow speeds of 100 to 4,000 feet per minute (0.5 to 20.32 m/s), temperatures of -4°F to 158°F (-20°C to 70°C), and a humidity range of 0 to 95 percent (non-condensing.) An improved cover design isolates the sensor head, which allows for ease of maintenance. A cover tamper feature indi- cates a trouble signal for a removed or improperly installed sensor cover. The Fire'Lite InnovairFIex housing provides a 3/ 4-inch conduit knockout and ample space to facilitate easy wir- ing and mounting of a relay module. The Fire'Lite InnovairFiex duct smoke detector can be custom- ized to meet local codes and specifications without additional wiring. The new InnovairFIex product line is compatible with all previous Innovair models, including remote test accessories. Features Photoelectric, integrated low-flow technology. Air velocity rating from 100 ft/min to 4,000 ft/min (0.5 m/s to 20.32 mIs). Versatile mounting options: square or rectangular configu- ration. Broad ranges for operating temperature (-4°F to 158°F, - 20°C to 70°C) and humidity (0% to 95% non-condensing). Patented sampling tube installs from front or back of the detector with no tools required. Cover tamper signal. Increased wiring space with a newly added 3/4" conduit knockout. Available space within housing to accommodate mounting of a relay module. Easily accessible code wheels on sensor head (sold sepa- rately). Clear cover for convenient visual inspection. Remote testing capability. Requires com line power only. Accommodates the installation of an addressable relay module, sold separately, (CRF-300) for applications requir- ing a Form-C relay. Specifications Size: (Rectangle) 14.38 in (37 cm) Length; 5 in (12.7 cm) Width, 2.5 in (6.6 cm) Depth. Size: (Square) 7.75 in (19.7 cm) Length; 9 in (22.9 cm) Width; 2.5 in (6.35 cm) Depth. Weight: 1.6 lb (0.73 kg). Operating Temperature Range: -4°F to 158°F (-20°C to 70°C). Storage Temperature Range: -22°F to 158°F (-30°C to 70°C). Operating Humidity Range: 0% to 95% relative humidity (non-condensing). Air Duct Velocity: 100 to 4,000 ft/min (0.5 to 20.32 m/s). Accessories Fire'Lite provides system flexibility with a variety of accesso- ries, including two remote test stations and different means of visible and audible system annunciation. As with our duct smoke detectors, all duct smoke detectors accessories are UL listed. D355PLs and DNRWs with a date code of 0013 or higher do not require external 24VDC for remote test applications when used with a remote-test-capable detector. ACCESSORY CURRENT LOADS AT 24 VDC Device Standby I Alarm RA100Z OmA I 12 mA Max RTSI51/ OmA 12mA Max RTS151KEY Agency Listings and Approvals Consult product manual for lists of compatible UL-Listed devices. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Con- sult factory for latest listing status. UL: S1059. ULC:S1059 DF-60430:C2 • 12/18/2012 - Page 1 of 2 CSFM: 3242-1653:0209. FM approved. Product Line Information D355PL: Intelligent non-relay photoelectric low flow smoke detector housing. Includes SD355R Detector. DNRW: Watertight intelligent non-relay photoelectric low flow duct smoke detector housing. Does not include detector head. SD355R(A): Remote test capable addressable low-profile photoelectric smoke detector. SD355(A): Addressable low-profile photoelectric smoke detec- tor. DCOIL: Remote test coil. Required for older DNR(W) duct detector housing. DST1: Metal sampling tube duct width up to 1 ft (0.3m). DST1 .5: Metal sampling tube duct widths up to 1 ft to 2 ft (0.3 to 0.6 m). DST3: Metal sampling tube duct widths up to 2 ft to 4 ft (0.6 to 1.2 m). DST5: Metal sampling tube duct widths up to 4 ft to 8 ft (1.2 to 2.4 m). DST10: Metal sampling tube duct widths up to 8 ft to 12 ft (2.4 to 3.7 m). DH4000E-1: Weatherproof enclosure. ETX: Metal exhaust tube duct, width 1 ft (0.3 m). M02-04-00: Test magnet. P48-21-00: End cap for metal sampling tubes. RA100Z: Remote annunciator alarm LED. RTS151: Remote test station. RTS1 51 KEY: Remote test station with key lock. Important Note DNRW duct detector housings with a date code of 0013 or higher do not require a DCOIL or auxiliary 24 VDC for remote test applications when used with a remote test capable detector. DNRW duct detector housings with a date code of 0012 or earlier require a DCOIL and auxiliary 24 VDC power for remote test applications. Fire-Lite® Alarms is a registered trademark of Honeywell International Inc. ©2012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. Z oil We cannot cover all specific applications or anticipate all requirements. BIGIlNI A 111IRIMC11W All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2— DF-60430:C2 • 12/18/2012 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 3240-0075:0221 Page 1 of 1 CATEGORY: 3240 -- DUCT SMOKE DETECTOR HOUSING/BASE LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Model *D355PL analog photoelectric duct smoke detector housing. Unit consists of a duct detector housing, exhaust tubes, and separately listed Fire-Lite Alarms' Model 5D355 or 5D355R detector heads (OSFM Listing No. 7272-0075:194). Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24VDC INSTALLATION: In accordance with listee's printed installation instruction, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, air velocity and UL label. APPROVAL: Listed as conventional photoelectric duct smoke detector housing for use with separately listed fire alarm control units. Refer to listee's Installation Instruction Manual for details. XLF: 3240-1653:0209 01-02-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DF-52121:E • E-325 MMF-300(A) Series, MDF-300 Addressable Monitor Modules General Four different monitor modules are available for Fire-Lite's intelligent control panels to suit a variety of applications. Moni- tor modules are used to supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (MMF-302(A)). MMF-300(A) is a standard-sized module (typically mounts to a 4" [10.16 cm] square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input devices. MMF-301(A) is a miniature monitor module a mere 1.3" (3.302 cm) H x 2.75" (6.985 cm) W x 0.65' (1.651 cm) D that super- vises a Style B (Class B) circuit of dry-contact input devices. Its compact design allows the MMF-301(A) to be mounted in a single-gang box behind the device it monitors. MMF-302(A) is a standard-sized module used to monitor and supervise compatible two-wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit. MDF-300(A) is a standard-sized dual monitor module used to monitor and supervise two independent two-wire Style B (Class B) dry-contact initiating device circuits (IDCs) at two separate, consecutive addresses in intelligent, two-wire sys- tems. LiteSpeedTm is a communication protocol developed by Fire-Lite Engineering that greatly increases the speed of com- munication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other communication protocols. MMF.300(A) Monitor Module Built-in type identification automatically identifies this device as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on MS-9600 series panels, 01 - 99 on other compatible systems. LED flashes during normal operation and latches on steady to indicate alarm. The MMF-300(A) Monitor Module is intended for use in intelli- gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The MMF-300(A) can be used to replace M300(A) modules in existing systems. MMF-300(A) APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterfiow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special (a Fire-LIWALWMS by Honeywell MMF-300(A) (Type H) supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. MMF-300(A) OPERATION Each MMF-300(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). MMF-300(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.0 mA (LED on). Average operating current: 375 pA (LED flashing), I com- munication every 5 seconds, 47k EOL. Maximum IDC wiring resistance: 1500 Ohms. Maximum IDC Voltage: 11 Volts. EOL resistance: 47K Ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. MMF-301 (A) Mini Monitor Module Built-in type identification automatically identifies this device as a monitor module to the panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. DF-52121:E • 07/30/2015 - Page 1 014 Tinned, stripped leads for ease of wiring. Direct-dial entry of address: 01 - 159 on MS-9600 series panels, 01 - 99 on other compatible systems 1415 0 1 ADDRESS 0 1 I 3 2 2 1_____ 12 31 8 76 8 76 LOOP _____ Ho TENS ONES II IIi oHllw j 0110 13 jII II-j U.i H II i 0 The MMF-301(A) Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The MMF-301 (A) is intended for use in intelligent, two-wire systems where the individual address of each module is selected using rotary switches. It provides a two-wire initiat- ing device circuit for normally-open-contact fire alarm devices. The MMF-301(A) can be used to replace M301 (A) modules in existing systems. MMF-301(A) APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterfiow devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit/ device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor (provided) terminates the circuit. MMF-301(A) OPERATION Each MMF-301(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). MMF-301(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Average operating current: 350 pA, 1 communication every 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Shorted). Maximum IDC wiring resistance: 1500 Ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 450 pA. EOL resistance: 47K Ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3 (3.302 cm) high x 2.75° (6.985 cm) wide x 0.65" (1.651 cm) deep. Wire length: 6° (15.24 cm) minimum. MMF.302(A) Interface Module Supports compatible two-wire smoke detectors. Page 2 of 4— DF-52121:E • 07/30/2015 Supervises IDC wiring and connection of external power source. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry entry of address: 01 - 159 on MS-9600 series panels, 01 —99 on other compatible systems. LED flashes during normal operation. LED latches steady to indicate alarm on command from control panel. The MMF-302(A) Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (normal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being monitored must be UL compatible with the module. The MMF-302(A) can be used to replace M302(A) modules in existing systems. MMF-302 (A) APPLICATIONS Use the MMF-302(A) to monitor a zone of two-wire smoke detectors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 3.9 K Ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resistance is 25 Ohms). Install ELR across terminals 8 and 9 for Style D application. MMF-302(A) OPERATION Each MMF-302(A) uses one of the available module addresses on an SLC loop, It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). MMF-302(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 Ohms. Average operating current: 270 pA, 1 communication and 1 LED flash every 5 seconds, 3.9k eol. EOL resistance: 3.9K Ohms. External supply voltage (between Terminals TIO and Til): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vm,s maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. MDF.300(A) Dual Monitor Module The MDF-300(A) Dual Monitor Module is intended for use in intelligent, two-wire systems. It provides two independent two- wire initiating device circuits (lDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices. The module has a single panel- controlled LED. NOTE: The MDF-300(A) provides two Style B (Class B) IDC cir- cuits ONLY. Style 0 (Class A) IDC circuits are NOT supported in any application. MDF-300(A) SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Average operating current: 750 pA (LED flashing). Maximum IDC wiring resistance: 1,500 Ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 pA EOL resistance: 47K Ohms. Temperature range: 32° to 120°F (0° to 49°C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. MDF-300(A) AUTOMATIC ADDRESSING The MDF-300(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the MDF-300(A) is set to address "26", then it will automati- cally assign itself to addresses "26" and "27". NOTE: "Ones" addresses on the MDF-300(A) are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. CAUTION: Avoid duplicating addresses on the system. Installation MMF-300(A), MMF-302(A), and MDF-300(A) modules mount directly to a standard 4(10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and installa- tion instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regu- lations. These modules are intended for power-limited wiring only. The MMF-301(A) module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S2424. ULC: S2424. FM Approved. CSFM: 7300-0075:0185. MEA:72-01-E. Product Line Information NOTE: "A" suffix indicates ULC-listed model. MMF-300(A): Monitor module. MMF-301 (A): Monitor module, miniature. MMF-302(A): Monitor module, two-wire detectors. MDF-300(A): Monitor module, dual, two independent Class B circuits. SMB500: Optional surface-mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN 51309. Architects/Engineers' Specifications Specifications of these devices and all FireLite products are available from FireLite. DF-52121:E •07/30/2015 - Page 3 of 4 Fire-LiteO is a registered trademark and LiteSpeedTM and FireWatchTM are trademarks of Honeywell International Inc. l2015 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I So 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENINBIN &WMIlUTIONG QUALITY SYSTEMS All specifications are subject to change without notice. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 4 of 4— DF-52121:E • 07/30/2015 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION M171' MIMI OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0075:0185 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Models MDF-300, MMF-301, MMF-300, MMF-302, MCF-300 monitor modules; Models CRF-300 and CMF-300 control modules; and MMF-302-6 six zone interface signaling device module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 15-32 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed electrically compatible fire alarm control units. NOTE: *Rev. 05-06-05 JW 8 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DF-52013:D • E-100 BG-1 2LX Addressable Manual Pull Station General The Fire-Lite BG-12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that includes an addressable interface (mounted inside) for Fire-Lite's addressable fire alarm control panels (FACPs) Because the BG-12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Features Maintenance personnel can open station for inspection and address setting without causing an alarm condition. Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. Handle latches in down position and the word ACTIVATED" appears to clearly indicate the station has been operated. Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mm2 wire). Can be surface mounted (with SB-10 or SB-I/O) or semi- flush mounted. Semi-flush mount to a standard single- gang, double-gang, or 4' (10.16 cm) square electrical box. Smooth dual-action design. Meets ADAAG controls and operating mechanisms guide- lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force. Highly visible. Attractive shape and textured finish. Key reset. Includes Braille text on station handle. Optional trim ring (BG12TR). Meets UL 38, Standard for Manually Actuated Signaling Boxes. Construction Shell, door, and handle are molded of durable polycarbonate material with a textured finish. Specifications Shipping Weight: 9.6 oz. (272.15 g) Normal operating voltage: 24 VDC. Maximum SLC loop voltage: 28.0 VDC. Maximum SLC standby current: 375 pA. Maximum SLC alarm current: 5 mA. Temperature Range: 32°F to 120°F (0°C to 49°C) Relative Humidity: 10% to 93% (noncondensing) For use indoors in a dry location Installation The BG-12LX will mount semi-flush into a single-gang, double- gang, or standard 4 (10.16 cm) square electrical outlet box, or will surface mount to the model SB-i 0 or SB-I/O surface back- box. If the BG-12LX is being semi-flush mounted, then the optional trim ring (BG12TR) may be used. The BG12TR is FireLiTerAtarms by Honeywell usually needed for semi-flush mounting with 4 (10.16 cm) or double-gang boxes (not with single-gang boxes). Operation Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word "ACTI- VATED" (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; clos- ing the door automatically resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address settings (1 - 159 with Breakaway Tab removed for MS-9600 Series, 1 - 99 and MS-9200UDLS, 1 —50 for MS-9050UD). Architectural/Engineering Specifications Manual Fire Alarm Stations shall be non-coded, with a key- operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated sta- tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red-colored polycarbonate material with clearly visible operat- ing instructions provided on the cover. The word FIRE shall appear on the front of the stations in white Letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-10 or SB-I/O; or semi-flush mounting on a standard single-gang, double-gang, or 4 (10.16 cm) square electrical box, and shall be installed DF-520130 • 4/13/2012 - Page I of 2