Loading...
HomeMy WebLinkAbout5958 AVENIDA ENCINAS; ; FPC2017-0252; Permiti ff :iiJIil 1AI6]1i Ccity of Carlsbad Au~~ UD(~ Print Date: 10/24/2022 Permit No: FPC2017-0252 Job Address: 5958 AVENIDA ENCINAS, CARLSBAD, CA 92008-4405 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2100905100 Track #: Applied: 08/25/2017 Valuation: $715,156.00 Lot #: Issued: 10/03/2017 Occupancy Group: Project #: Finaled Close Out: 03/15/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check #: INSPECTOR: Fieri, Dominic Plan Check #: Stowe, Daniel Wong, Cindy Project Title: Description: DRAFT REPUBLIC -SPRINKLER MONITORING SYSTEM Applicant: FPContractor: AZTEC FIRE AND SAFETY . AZTEC FIRE AND SAFETY INC LUIS GONZALEZ 8108 COMMERCIAL ST 8108 COMMERCIAL ST LA MESA, CA 91942-2926 LA MESA, CA 91942-2926 (619) 464-5625 (619) 832-5787 FEE AMOUNT FIRE Expedited Plan Review Per Hour - Office Hours $132.00 FIRE Sprinkler Monitoring $371.00 Total Fees: $503.00 Total Payments To Date: $503.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1760-602-8561 f I www.carlsbadca.gov (E)POTTER CONVENTIONAL FIRE PANEL! The Symbol of Protection SPRINKLER MONITORING PANEL Features: FPC20I7-0252 5958 AVENIDA ENCINAS 6 Programmable Initiating Device Circuits Class A or Class B Waterfiow Initiating Circuit 2 Wire Smoke Detector Compatibility 1.0 Amp Power Supply 1 Notification Circuit rated at 0.5 Amps Regulated Strobe Synchronization for Potter/AMSECO, Gentex, System Sensor and Cooper/Wheelock pFC Series,,, OpOTTER F SIGNAUNG NYC Fire Dept. Certificate of C&U, 9 Approval LISTED 6184 Approved for DACT or Stand S735 7165-0328:0204 Alone IF Communications General Description The PFC-6006 is a listed small conventional fire system ideally suited to monitor a small fire system such as a fire sprinkler system. The first input is selectable as a Class A or Class B water flow input and the other five zones are selectable from a menu of options including two-wire smoke detection. The panel has a 1.0 amp power supply that powers the panel, charges the batteries and supplies 0.5 amps to a notification appliance circuit and 0.5 amps of auxiliary power. The auxiliary power is programmable as constant or resettable. The control panel is in a metal cabinet with a key lock and lexan window for viewing the system status. The printed circuit assembly is mounted for quick removal and installation to allow the cabinet to be installed with minimal effort. The cabinet houses up to two 12VDC, 18 AH batteries. 0.5 Amp Auxiliary Power, Programmable as Constant or Resettable 2 x 16 LCD display with system LEDs for clear system status Keypad for system features - P-Link for Remote Annunciator Connections Capacity to charge and house 18A}{ batteries Onboard Dual Line Digital Alarm Communicator Built-in Ethernet Connection with listed IF Communicator Ability to E-mail system status, reports and system configuration Service Reminder E-mails Electrical Specs AC Mains 1.0 amp @ 120 VAC 60 Hz Battery 105 mA Standby l60mAAlarm Dimensions 18 1/2"Hx 14 1/4Wx43I4" D Thepanel has a dual telephone line digital alarm communicatortransmitter (DACT) built on-board. One or both telephone lines may be enabled to allow communication to a remote monitoring station. In addition, an updatedpanel configuration maybe sent to the panel through the telephone lines. The panel has line in and line out to allow the panel to be installed ahead of other telephone equipment on the premises. - The panel will support up to four (4) of the RA-6075 remote annunciators on the P-Link bus. These annunciators include a metal enclosure with a key lock and provide full functionality of the system. The panel is pre-programmed from the factory for monitoring a typical wet or dry fire sprinkler system. The programming maybe changed using the Potter Fire Panel Programmer (available free from www.pottersignal. corn) and a standard Ethernet cable. The default program is as follows: The display is a thirty-two (32) character LCD with system status LEDs. The system status is clearly displayed and the panel includes a history Input 1 - Waterfiow buffer for past events. The key pad allows navigation into the system Input 2- Smoke Detection (two-wire) menu, limited programming and system control. The condition and Input 3 - Manual Pull Station events on the panel are clearly displayed to allow the user and installer Input 4-Non-Latching Supervisory to determine the system status. Input 5 - Valve Tamper Input 6-Valve Tamper Potter Electric Signal Co., LLC • St. Louis, MO • Cust Service: 866-240-1870 • Tech Support:866-956-121 I • Canada 888-882-1833. www.pottersignal.com PRINTED IN USA MKT #8830038 - REV B PAGE 1 OF 2 01/17 CONVENTIONAL FIRE PANEL! (E)POTTER PFC-6006 The Symbol of Protection SPRINKLER MONITORING PANEL General Description (Cont.) In the standard program, Input 1 is defaulted as a Water flow zone. Input 1 is the only Class A/Class B zone. The panel will automati- cally determine Class A or B based on wiring and the presence of the end of line resistor. All of the inputs may be programmed for General Alarm, Waterfiow, Two-Wire Smoke Detector, Heat Detector, Manual Pull Station, Non-latching Supervisory, Latching Supervisory, or Valve Tamper. The NAC is listed for strobe synchronization and the panel is listed with Potter/AMSECO, Gentex, System Sensor, and Cooper Wheelock signals. Please refer to the Potter Notification Compatibility Docu- ment for the maximum number of strobe devices that may be con- nected. The maximum output is 0.5 amps. The Ethernet connection may be connected to a building network with Internet to provide e-mail notifications of system status, reports, or system configuration. In addition, the Ethernet connection is listed for - IP reporting to a monitoring station. CAUTION: De-Energize Unit Prior to Servicing I20iIAC 60f Lin ch ~,, majit / U5e 14 AWGor gustge wlif.t With WV iiuItIor 4 W/4EEIG: FffiCOAEJE1CV F rs)M U TRANSMITTING DEVICES MAY IMPMIMItNDED OPERATION Of THE CONTROL UNIT. MAINTAIN A MINIMUM OP CM BETWEEN TAJ1SM11ING DEVICES AND COtlTFOt. UNIT, AVTRTIS&EMEMT: fA[OrREOU(NCLS tMSE5 PAR LESDISPOSUIIS DETMSMISSM PWVEMF PjIFtt AurorcIrIEMEt'trPRE) (xi POSIt tIE CCNThOEE. h1AIN1ThiI ONE DISTANCE LYAU MOINS 30CM ENTRE LES DISPOSITIFS TIAHSAtISSION(TLf POSit 0€ CONTROII, 12 C14,_25AMP nrs WIC FUSE L Op 111:10a;~M Ott Itlnipedanc0i,,Jues SbIG, W,r Ut. Ejs 5'Icatcr VIM fiItl4 CWTRa U4 'T th frAkiWrIilc1fi IT 3ec rj rwcaoik jjj,(,j1tejfe(in1A 1 ThIs 3W4 jss rry tntMIIr. cW4.jIndudr ss IWCWM JrIsSI,5fWfir5 (M*Cc.flf 5Mi,s$k nd TzIrn Tn • 3r, Mlofl prsIscIsTIsI Ith s'coolw wheelcd PIIsm Nos. 1,4I0IsI9. PrtM Lk5iir C.rpr,j LL IjiTIsLOI,hW rcIrs, th47 CPR par Isa, 1Mie In 'JW. I, figI 9. PhI 54IIs2t 10)sliJ14 PLACK @I-pOffFR LIPUNIOH DAUAM UIWIsT*M4,al U 9IIUM1pr5 r UIsIsEMID o WMUflLI tuJ L=JJ mmm SPETS 14159.151. PIsSSwcbI. pq E;IIHE IESQ W5PI DFTNE, PWIsIflFPr5 b Cr,ntrnaI Inputs, rulifi p,ciLI &iisppn4l Wie irW*Is IsslecIhI Rrrvrernrnt, 5rmrrS Lir fII IrIr hIs ruMlleson r,dE rdrcr urenWI'rsrLy. II,...uw oF.,,,r Irnirdwi, l5 irt rbceAIer brr,,,dw,or.3 nd Prt.I r cn,da,cr wIsh issisibsin rnsr,.,sI Psrl rEs,.,r srdOpssbrrnsturhssn Pat t l,s$rrcl Usleetuc C ibItyklrnlhIr 'IsY nFrA cimef oalP514.Z1edcdTdWSCCIs1lIC4 Ufit (SI 'illS I4hiqss II TiE strict F'PA 72, !!! L-Jc1J - PrF,QiLi5suIiE4 - lecllflewry - :snsll 514 II' 5tt4I5 fIEldS fl0l1-5WlirnIt4I IIRuCE 155510 CESIM I3$LPSDTLcTED Pc4Eill5 UNIT FOR uLCr1'IsLtA1ONs Use ssc I2II2Yb4iU14a coniectedln Iuiw. 15155 WTHOI2Is SPItS. IS IN AC(CDAI4CE '14TH C55 Clii. 502 PCI LLE.C1FLCL IN5T4U.ATIQ14S C,114.4DIANELECTTIIC4L C2DII. PMII S IECTIOPIS 32 LOCuS. 555 PE1YIES t I'CO55(,A, M. 55.14F, PFC-6006 - Sprinkler Monftoring Panel I. • F, •$ r , b rT5DIsc4c11cW MfiICL cTWIs1I isirr APROWIIEITIsT TM TIME TO TTTOI113M II5NAI. AC111ATCFt ACAU1ION TIIIIV C4TECTT$TIIAT Apa5IfrnT4N 145 CITTIIMUTY LIII 141Is TO LiE SliD Potter Electric Signal Co.,LLC St. Louis, MO • CustService: 866-240-1870 •Tech Support: 866-956-1211• Canada 888-882-1833• www.pottersignal.com PRINTED IN USA MKT #8830038- REV B PAGE 2 OF 2 01/17 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - _____ FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0328:0204 Page 1 of 1 CATEGORY: 7165--FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: Potter Electric Signal Col 609 Park 370 Place, Hazelwood, 63042 United States Contact: Bill Witherspoon (314) 595-6900 Fax (314) 595-6999 Email: biIIwpottersignal.com - DESIGN: Model PFC-6006 fire alarm control panel. Automatic, Manual, waterfiow and sprinkler supervisory type device and local, auxiliary, remote station (PPU), proprietary (PPU) and central station (PPU) services. Refer to listee's Installation Instruction Manual for details. RATING: 120 VAC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, rating and UL label. APPROVAL: Listed as fire alarm control units when use with separately listed electrically and functionally compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. 07-25-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division S VS IL- S I\i5(•)/ Photoelectric Smoke Detectors System Sensor j3" series smoke detectors represer significant advancement in conventional detect The j3 family is founded on three principles: installation ease, intelligence, and instant inspection. Features Plug-in detector line, mounting base included Large wire entry port In-line terminals with SEMS screws Mounts to octagonal and single-gang back boxes, 4-square back boxes, or direct to ceiling Stop-Drop 'N Lock attachment to base Removable detector cover and chamber Built-in remote maintenance signaling Drift compensation and smoothing algorithms Simplified sensitivity measurement Wide-angle, dual-color LED indication Loop testing via EZ Walk feature Built-in test switch Agency Listings ® MEA MSFM C((T)US LISTED APPROVED approved approved S911 3011446 7272-1653:152 290-01-E 2093 3180932 Installation ease. The i3 line redefines installation ease with its plug-in design. This allows an installer to pre-wire bases (included with heads). The large wire entry port and in-line terminals provide ample room for neatly routing the wiring inside the base. The base accommodates a variety of back box mounting methods as well as direct mounting with drywall anchors. To complete the installation, i3 heads plug into the base with a simple Stop-Drop 'N Lock" action. Intelligence. i3 detectors offer a number of intelligent features to simplify testing and maintenance. Drift compensation and smoothing algorithms are standard with the i3 line to minimize nuisance alarms. 2-wire i3 detectors can generate a remote LED- indicated maintenance signal when connected to the 2W-MOD2 loop test/maintenance module or a panel equipped with the i protocol. The SENS-RDR, a wireless device, displays the sensitivityof P detectors in terms of percent-per-foot obscuration. Instant inspection.The i3 series provides wide-angle red and green LED indicators for instant inspection of the detector's condition: normal standby, out-of-sensitivity, alarm, or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the i3 protocol, the EZ Walk loop test feature is available on 2-wire j3 detectors. This feature verifies the initiating loop wiring by providing LED status indication at each detector. Smoke Detector Specifications Smoke detector shall be a System Sensor i3 Series model number .listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems. The detector shall be a photoelectric type (Model 2W-B, 4W-B) or a combination photoelectric/thermal (Model 2WT-B, 4WT-B) with thermal sensor rated at 135°F (57.2'C). The detector shall include a mounting base for mounting to 31/2-inch and 4-inch octagonal, single-gang, and 4-inch square back boxes with a plaster ring, or direct mount to the ceiling using drywall anchors. Wiring connections shall be made by means of SEMS screws. The detector shall allow pre-wiring of the base and the head shall be a plug-in type. The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the UL smoke box. The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms. The detector shalt provide dual- color LED indication that blinks to indicate power up, normal standby, out of sensitivity, alarm, and freeze trouble (Model 2W1-B, 4WT-8) conditions. When used in conjunction with the 2W-MOD2 module, 2-wire models shalt include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually. Operating Voltage Nominal: 1 2/24 V non-polarized Minimum: 85V Maximum: 35V Maximum Ripple Voltage 30% peak to peak of applied voltage Standby Current 2-wire: 50 pA maximum average; 4-wire: 50 pA maximum average Maximum Alarm Current 2-wire: 130 mA limited by control panel; 4-wire: 20 mA @12 V, 23 mA @ 24V Peak Standby Current 2-wire: 100 uA 4-wire: n/a Alarm Contact Ratings 2-wire: n/a; 4-wire: 0.5 A @ 30V AC/DC - Dimensions (including base) 53 inches (127mm) diameter; 2.0 inches (51 mm) height Weight 630z(178g) Operating Temperature Range 2W-B and 4W-B: 32°F to 120°F (0°C to 49°C); 2WT-B and 4W1-B: 32°F to 100°F (0°C to 37.8°C) Operating Humidity Range 0 to 95% RH non-condensing Thermal Sensor 135°F (572°C) fixed Freeze Trouble 2WT-B and 4WT-B only: 41°F (5°C) Sensitivity 2.50/Q/ft nominal InputTerminals 14 to 22 AWG Mounting 31/2-inch octagonal back box 4-inch octagonal back box Single-gang back box 4-inch square back box with a plaster ring Direct mount to ceiling LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal (standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Ordering Information aftla 2W-B No 2-wire 130 mA max. limited by control panel 2WT-B Yes 2-wire 130 mA max. limited by control panel 4W-B No 4-wire 20 mA @ 12 V, 23 mA @ 24 V 4W1-B Yes 4-wire 20mA@ 12V,23 mA@24V Accessories 2W-MOD2 2-wire loop test / maintenance module SENS-RDR Sensitivity reader RT Removal / replacement tool A77-AB2 Retrofit adapter bracket, 6.6 inch (16.76 cm) diameter 1.'Yt'T159I/iI SEA15OR System Se~sor. 3825 Ohio Avenue. St. Charles, IL 60174 Phone: 800-SENSOR2. Fax: 630-377-6495 current product informat-, Incl uding the latest wrAon of th Is date sheet. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL 0LISTING SERVICE - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING No. 7272-1653:0152 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.KireyevhoneywelI.com - DESIGN: Models 2W-B, 2WT-13, 4W-B and 4WT-B photoelectric type smoke detectors. Models 2W-B and 2WT-B are 2-wire and model 4W-B and 4WT-13 are 4-wire detectors. Models 2WT-13 and 4WT-B employ a thermistor type heat sensor (1357). The heat sensor is are supplemental to the detector and is not intended for use as a required heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 8.5 - 35 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. For vertical wall or ceiling mount. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. Suitable for installation in open areas with air velocity range from 0-1000 ft/mm. NOTE: Formerly 7272-1209:210 - 06-20-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division VSR (E)POTTER VANE TYPE WATERFLOW The Symbol of Protection ALARM SWITCH WITH RETARD Specifications subject to change without notice. Ordering Information Nominal PipeSize Model Part Number 2' DN50 VSR-2 1144402 2 1/2" DN65 VSR-2 1/2 1144425 3" DN80 VSR-3 1144403 3 1/2" - VSR-3 1/2 1144435 DN100 VSR-4 1144404 - VSR-5 1144405 DN150 VSR-6 1144406 8" DN200 VSR-8 1144408 Optional: Cover Tamper Switch Kit, stock no. 0090148 Replaceable Components: Retard/Switch Assembly, stock no. 1029030 UL, CUL and CSFM Listed, FM Approved,LPCBApproved,For CE Marked (EN12259-5) /VdS Approved model use VSR-EU Service Pressure: 450 PSI (31 BAR)-UL Flow Sensitivity Range for Signal: 4-10 GPM (15-38 LPM) - UL Maximum Surge: 18 FPS (5.5 m/s) Contact Ratings: Two sets of SPDT (Form C) 10.0 Amps at 125/250VAC 2.0 Amps at 30VDC Resistive lomAmpsmin. at24VDC Conduit Entrances: Two knockouts provided for 1/2" conduit. Individual switch compartments suitable for dissimilar voltages. Environmental Specifications: NEMA 4/IP54 Rated Enclosure suitable for indoor or outdoor use with factory installed gasket and die-cast housing when used with appropriate conduit fitting. Temperature Range: 40°F -120°F, (4.5°C - 49°C) - UL Non-corrosive sleeve factory installed in saddle. Service Use: Automatic Sprinkler NFPA-13 One or two family dwelling NFPA-13D Residential occupancy up to four stories NFPA-13R National Fire Alarm Code NFPA-72 Installation must be performed by qualified personnel and in accordance with all national and local codes and ordinances. Shock hazard. Disconnect power source before servicing. Serious injury or death could result. Risk of explosion. Not for use in hazardous locations. Serious injury or death could result. CAUTION Waterfiow switches that are monitoring wetpipe sprinkler systems shall not be used as the sole initiating device to discharge AFFF, deluge, or chemical suppression systems. Waterfiow switches used for this application may result in unintended discharges caused by surges, trapped air, or short retard times. Important: This document contains important information on the installation and operation of the VSR waterfiow switches. Please read all instructions carefully before beginning installation. A copy of this document is required by NFPA 72 to be maintained on site. General Information Enclosure The Model VSR is a vane type waterfiow switch for use on wet sprinkler The VSR switches and retard device are enclosed in a general purpose, systems. It is UL Listed for use on a steel pipe; schedules 5 through 40, die-cast housing. The cover is held in place with two tamper resistant sizes 2" - 6" and is UL Listed and FM Approved for use on steel pipe; screws which require a special key for removal. A field installable schedules 10 through 40, sizes 2" thru 8" (50 mm thru 200 mm). LPC cover tamper switch is available as an option which may be used approved sizes are 2" thru 8" (50 mm thru 200 mm). See Ordering to indicate unauthorized removal of the cover. See bulletin number Information chart. 5401103 for installation instructions of this switch. The VSR may also be used as a sectional waterfiow detector on large systems. The VSR contains two single pole, double throw, snap action switches and an adjustable, instantly recycling pneumatic retard. The switches are actuated when a flow of 10 GPM (38 LPM) or more occurs downstream of the device. The flow condition must exist for a period of time necessary to overcome the selected retard period. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 866-956-1211/Canada 888-882-1833 • www.pottersignal.com PRINTED IN USA MFG. #5401146 - REV M PAGE 1 OF 4 11115 (E)POTTER VSR The Symbol of Protection ALARM SWITCH WITH RETARD Installation (see Fig. 1) These devices may be mounted on horizontal or vertical pipe. On horizontal pipe they shall be installed on the top side of the pipe where they will be accessible. The device should not be installed within 6" (15 cm) of a fitting which changes the direction of the waterfiow or Within 24" (60 cm) of a valve or drain. NOTE: Do not leave cover off for an extended period of time. Drain the system and drill a hole in the pipe using a hole saw in a slow speed drill (see Fig. 1). Clean the inside pipe of all growth or other material for a distance equal to the pipe diameter on either side of the hole. Roll the vane so that it may be inserted into the hole; do not bend or crease it. Insert the vane so that the arrow on the saddle points in the direction of the waterfiow. Take care not to damage the non-corrosive bushing in the saddle. The bushing should fit inside the hole in the pipe. Install the saddle strap and tighten nuts alternately to required torque (see the chart in Fig. 1). The vane must not rub the inside of the pipe or bind in any way. Do not trim the paddle. Failure to follow these instructions may prevent the device from operating and will void the warranty. Do not obstruct or otherwise prevent I I the trip stem of the flow switch from moving when water flows as this could damage the flow switch and prevent an alarm. If an alarm is not desired, a qualified I I technician should disable the alarm system. I ADNOTLEAVE COVER OFF FOR Retard Adjustment Fig. 1 E.XTENDED PERIOD OF TM The delay can be adjusted by rotating the retard adjustment knob from 0 to the max setting (60-90 seconds). The time delay should be set at the minimum required to prevent false alarms TIGHTEN NUTS ALTERNATELY MOUNT ON PIPE SO ARROW ON SADDLE POINTS IN DIRECTION OF WATERFLOW CAUTION Hole must be drilled perpendicular to the pipe and vertically centered Refer to the Compatible Pipe/Installation Requirements chart for size. Correct Incorrect 8 ®3 DIRECTION OF WATERFLOW ROLL PADDLE IN OPPOSITE DIRECTION OF WATERFLOW lowing water activates device in one direction only.) M. t146-II 50mm ADAPTER ADAPTER i..- 20mm ±2mm MAX. DN50 ONLY USE (2) 5180162 ADAPTERS AS SHOWN ABOVE DWG# 1146-IF Compatible Pipe/ Installation Requirements Model Nominal Pipe Size Nominal Pipe O.D. Pipe Wall Thickness ___________ Hole Size U-Bolt Nuts Torque Lightwall Schedule 10 (UL) Schedule 40 (UL) BS-1387 (LPC) DN (VDS) inch mm inch mm inch mm inch mm inch mm inch mm inch mm inch mm ft-lb n-rn VSR-2 2 DN50 2.375 60.3 .065 1.651 0.109 2.77 0.154 3.91 0.142 3.6 0.091 2.3 1.25 +.125/- .062 33.0±2.0 VSR-2 1/2 2.5 - 2.875 73.0 .084 2.134 0.120 3.05 0.203 5.16 - - - - VSR-2 1/2 - DN65 3.000 76.1 - - - - - - 0.142 3.6 0.102 2.6 VSR-3 3 DN80 3.500 88.9 .083 2.108 0.120 3.05 0.216 5.49 0.157 4.0 0.114 2.9 2.00+125 50.8±2.0 20 27 VSR-3 1/2 3.5 - 4.000 101.6 - - 0.120 3.05 0.226 5.74 - - - - VSR4 4 DN100 4.500 114.3 .084 2.134 0.120 3.05 0.237 6.02 0.177 4.5 0.126 3.2 VSR-5 5 - 5.563 141.3 - - 0.134 3.40 0.258 6.55 - - - - VSR-6 6 DNISO 1 6.625 168.3 .115 2.921 0.134 3.40 0.280 7.11 0.197 5.0 0.157 4.0 VSR-8 8 DN200 1 8.625 219.1 - - 0.148 1 3.76 1 0.322 8.18 0.248 6.3 0.177 r4,51 NOTE: For copper or plastic pipe use Model VSR-CF. PRINTED IN USA MPG. #5401146 - REV M PAGE 2 OF 4 11115 Fig. 6 Mounting Dimensions 3.50 in 2.00 (50,8 DING. 1140.14 MINAL PIPE DIA. +1.75 in (+44.5 MM) FOR DN 50—DN 65 2-2.5 in MINAL PIPE DIA.+2.I25 in(+54.0MJd) FOR DN8O—DN2003-8üt Fig. 7 GREEN GROUND (E)POTTER The Symbol of Protection Fig. 2 Fig. 3 To remove knockouts: Place screwdriver at Break out thin section of cover when inside edge of knockouts, not in the centet wiring both switches from one conduit entrance. NOTICE Do not drill into the base as this creates metal shavings which can create electrical hazards and damage the device. Drilling voids the warranty. VSR VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD Fig. 4 Switch Terminal Connections Clamping Plate Terminal INC OINC . ,.. A WARNING An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire become dislodged from under the terminal. Failure to sever the wire may render the device inoperable risking severe property damage and loss of life. Do not strip wire beyond 3/8" of length or expose an uninsulated conductor beyond the edge of the terminal block. When using stranded wire, capture all strands under the clamping plate. ME Fig. 5 Typical Electrical Connections NEUTRAL FROM RRFAKFR BtAKER Notes: The Model VSR has two switches, one can be used to operate a central station, proprietary or remote signaling unit, while the other contact is used to operate a local audible or visual annunciator. For supervised circuits, see "Switch Terminal Connections" drawing and warning note (Fig. 4). NEUTRAL FROM BELL EOL (End Of Un,, Reslotoll woia Who,, connenting too UL Lined co.lt,OI ponel.ose the ponels sto, value fond,coltsope,vh Testing The frequency of inspection and testing for the Model VSR and its associated protective monitoring system shall be in accordance with applicable NFPA Codes and Standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). If provided, the inspector's test valve shall always be used for test purposes. If there are no provisions for testing the operation of the flow detection device on the system, application of the VSR is not recommended or advisable. A minimum flow of 10 GPM (38 LPM) is required to activate this device. se the person responsible for testing of the fire protection system that this system must be tested in accordance the testing instructions. PRINTED IN USA MPG. #5401146 - REV M PAGE 3 OF 4 11115 VSR (E)POTTER VANE TYPE WATERFLOW The Symbol of Protection ALARM SWITCH WITH RETARD Maintenance Inspect detectors monthly. If leaks are found, replace the detector. The VSR waterfiow switch should provide years of trouble-free service. The retard and switch assembly are easily field replaceable. In the unlikely event that either component does not perform properly, please order replacement retard switch assembly stock #1029030 (see Fig. 8). There is no maintenance required, only periodic testing and inspection. Retard/Switch Assembly Replacement (See Fig. 8) The Retard/Switch Assembly is field-replaceable without draining the system or removing the waterfiow switch from the pipe Make sure the fire alarm zone or circuit connected to the waterfiow switch is bypassed or otherwise taken out of service. Disconnect the power source for local bell (if applicable). Identify and remove all wires from the waterfiow switch. Remove the (2) mounting screws holding retard/switch assembly to the base. Do not remove the (2) retard housing screws. Remove the retard assembly by lifting it straight up over the tripstem. Install the new retard assembly. Make sure the locating pins on the retard/switch assembly fit into the locating pin bosses on the base. Re-install the (2) original mounting screws. Reconnect all wires. Perform a flow test and place the system back in service. Fl S REMOVE (2) ORIGINAL MOUNTING Fig. SCREWS HOLDING RETARD/SWITCH VZ ASSEMBLY 10 BASE BREAKOUTTHIN SECTIONOF COVER WHEN WIRING BOTH SWITCHES FROM ONE CONDUIT ENTRANCE. (2) ORIGINAL MOUNTING CREWS RETARD/SWITCH ASSEMBLY / DO NOT REMO\ (2) RETARD HOI SCREWS (2) LOCATD (2) LOCATII BOSSES IN DWG# 1146-10 Removal of Waterfiow Switch To prevent accidental water damage, all control valves should be shut tight and the system completely drained before waterfiow detectors are removed or replaced. Turn off electrical power to the detector, then disconnect wiring. Loosen nuts and remove U-bolts. Gently lift the saddle far enough to get your fingers under it. With your fingers, roll the vane so it will fit through the hole while continuing to lift the watertlow detector saddle. Lift detector clear of pipe. PRINTED IN USA MFG. #5401146- REV M PAGE 4 OF 4 11115 LISTING No. CATEGORY: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7770-0328:0001 7770 -- VALVES/SWITCHES LISTEE: DESIGN: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, 63042 United States - Contact: Bill Witherspoon (314) 595-6900 Fax (314) 595-6999 Email: BillWpottersignal.com Vane and pressure type water flow alarm switches listed below. Refer to listee's data sheet for detailed product description and operational considerations. - Vane Types: VSR-CF VSR-D VSR-FE-2 VS-SP VSR-SFT VSG VSR-C VSR-ST Pressure Type: VSR-F VSR-SF VS-F VSR-SFG VSR VSR-S VSR-SG WFS-B WFSR-C WFSPD-B PS10 PS-10A PS-100A WFSR-F PSIOO INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL or FM label. - APPROVAL: Listed as waterfiow alarm switches for use with fire sprinkler systems. Vane models may be used in wet pipe systems; pressure models may be used in wet or dry systems. Model VSR-CF is for use on K, L or M copper pipe (2, 2-1/2", 3", 4") and listed CPVC pipe (2', 2-1/2, 3"). Model VSR-SF for use on 1", 1-1/4", 1-1/2" and *2 steel, copper or listed plastic pipe. Model VSG is for low flow rate. Model VSR-SFG and VSR-SFT are for use on 1", 1-1/4', 1-1/2" and *2 plastic pipe. Models VS-F, VSR-F, VSR-FE and VSR-FE-2 is for use on 2", 2-1/2", 3", 3-1/2", 4", 5", 6", 8" and 10" pipe. *Model VSR is for use on steel pipe sizes from 2" through 8". Vane type switches may be used outdoors when the outdoor temperature never falls below 40oF. Rev*5172007 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct - operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division (E)POTTER PCVS Series The Symbol of Protection Control Valve Supervisory Switch Features NEMA 4X*(1P65) and 6P(IP67) *Enclosure is 4X. For additional corrosion protection of mounting hardware, use model PCVS-2 CR11 40° to 1400 (-40°C to 60°C) operating temperature range Visual Switch Indicators Two conduit entrances Adjustable length trip rod Accomodates up to 12AWG wire Switch detects tampering and valve closure RoHS compliant Two SPDT contacts POT1ER II I* '•°"" CE PCVS-2 Before any work is done on the fire sprinkler or fire alarm system, the building owner or their authorized representative shall be notified. Before opening any closed valve, ensure that opening the valve will not cause any damage from water flow due to open or missing sprinklers, piping, etc. SIGNAUNG c®us IS (E LISTED APPROVED Important: This document contains important information on the installation and operation of PCVS valve supervisory switches. Please read all instructions carefully before beginning installation. A copy of this document is required by NFPA 72 to be maintained on site. Description Technical Specifications The Model PCVS is a weather proof and tamper resistant switch for monitoring the open position of fire sprinkler control valves of the wall and yard post indicator and butterfly types. Two SPDT (Form C) contacts are provided which will operate when the valve position is altered from an open state. The unit mounts in a 1/2" NPT tapped hole in the post indicator or butterfly valve housing. The device is engaged by the indicating assembly of the post indicator or the operating mechanism of the butterfly valve, actuating switches when the valve is fully open. The unit should be installed where it is accessible for service. The cover is held in place by two tamper resistant screws that require a special tool to remove. The tool is furnished with each device. Testing The operation of the PCVS and its associated protective monitoring system shall be tested upon completion of the installation and in- spected, tested and maintained in accordance with all applicable local and national codes and standards and/or the Authority Having Juris- diction, (manufacturer recommends quarterly or more frequently). A minimum test shall consist of turning the valve operating mechanism towards the closed position. The PCVS shall operate within the first two revolutions of the operating mechanism. Fully close the valve and ensure the PCVS does not restore. Fully open the valve and ensure that the PCVS restores to normal. Dimensions See Fig 10 Weight 1.0 lbs (0,45 kg) Cover: Die Cast Finish: Red Powder Coat Enclosure Base: Die Cast Finish: Black Powder Coat All parts have corrosion resistant finishes Tamper Resistant Screws Cover Tamper Optional Cover Tamper Switch Available PCVS-2: Two Sets of SPDT (Form C) Contact 10.0 Amps at 125/250 VAC Ratings 2.0 Amps at 30VDC Resistive lOmAmps minimum at 24 VDC -40° F to 140°F (-40°C to 60°C) Environmental NEMA 4X (IP 65) and NEMA 6P Enclosure (IP67) Limitations (Use suitably rated conduit and connector) Indoor or Outdoor Use (See PWSU-EX Bulletin 5400694 for Hazardous locations) Conduit Two Knockouts for 1/2" conduit provided Entrances (See Notice on Page 7 and Fig. 11 on Page 6) Service Use NFPA 13,13D, 13R, 72 Specifications subject to change without notice Potter Electric Signal Company, LLC • St. Louis, MO • Tech Support: 866-956-0988 / Customer Service: 866-572-3005 • www.pottersignal.com 5401526-REVF • 8/15 PAGE IOF7 113/8" (28,9 cm) I Steel Tripping Block Replace "--'aces Glass LIT ssembly Lockflut (E)POTTER PCVS Series The Symbol of Protection Control Valve Supervisory Switch Theory Of Operation The PCVS is a spring loaded switch. It is in normal position when the trip rod is pulling against the spring force. Normal is when the switch is installed on the valve and the valve is fully open. As the valve closes, the valve actuator moves away from the trip rod of the PCVS and the spring on the PCVS pulls the trip rod over and trips the switch. - Alternate Window Installation and Moving Hood Installation Target Moves Up as Valve is Shut Fig Subject to the approval of the "authority having jurisdiction" the alternate method of installation shown in Fig. 1 may be used. In this method, one of the glass windows of the housing is replaced with a 1/4" thick metal plate that is cut to fit in place of the glass and drilled and tapped to recieve 1/2" NPT pipe nipple. In some cases it may be necessary to attach an angle bracket to the target assembly to engage the PCVS trip rod. Hood Moves Down as Valve Is Shut Fig 2 If the target is stationary and a hood arrangement is used, such as is shown in Fig. 2, the hood must be drilled with a 23/32" drill and tapped with a 1/2" NPT. The center line of this hole should be 1/8" - below the portion of target assembly that strikes the PCVS trip rod. The 113/8" dimension shown is for a Clow Valve. Flexible conduit must be used for this type of installation. (More on pg. 3). Potter Electric Signal Company, LLC • St. Louis, MO • Tech Support: 866-956-0988 / Customer Service: 866-572-3005 • www.pottersignal.com 5401526- REV F • 8/15 PAGE 2OF7 (E)POTTER PCVS Series The Symbol of Protection Control Valve Supervisory Switch Typical Installations On Post Indicator Valve Housings Fig Fig down Ut. NOTE: Before any work is done on the fire sprinkler or fire alarm system, the building owner or their authorized representative shall be notified. Before opening any closed valve, ensure that opening the valve will not cause any damage from water flow due to open or missing sprinklers, piping, etc. Position the valve to fully open ("OPEN" should appear in the window of the housing). Partially close the valve while observing the direction that the target assembly moves. Reopen the valve. If the valve housing is predrilled with a 1/2" NPT for installation of a monitoring switch, remove the 1/2" plug and fully open the valve. Make sure that "OPEN" appears in the window of the housing. GO TO STEP NO. 6. If the valve is not pre-drilled for 1/2" NPT, remove the head and target assembly (consultation with valve manufacturer is recommended). If the target assembly moved up as the valve was closed, measure the distance from the bottom of the head to the lower part of the target assembly that will contact the trip rod of the PCVS (see Fig. 3). This is usually a plate or baron the target assembly, on a side adjacent to the "OPEN/SHUT" plates. Subtract 1/8" from the measurement. If the target moved down as the valve was dosed, measure the distance from the bottom of the head to the upper portion of the target assembly that will contact the trip rod of the PCVS (see Fig. 4). Add 1/8" (3,2mm) to this measurement. Mark the housing at the proper location. Using a 23/32" (18,2mm) drill bit, drill and then tap a 1/2" NPT in the housing on the side that coincides with the portion of the target assembly that will engage the trip rod of the PCVS. Replace the head and target assembly. Loosen the socket head screw that holds the nipple in the PCVS and remove the nipple. Screw the locknut that is provided onto the nipple. Screw the nipple into the 1/2" NPT hole in the valve housing hand tighten. Tighten the locknut against the valve housing to secure the nipple firmly in place. Insert a scale or probe thm the nipple to measure the distance from the open end of the nipple to the target assembly. Subtract 1/2" (12,5mm) from this measurement. NOTE: In some cases, it may be necessary to attach an angle bracket to the target assembly to engage the PCVS trip rod. Using the special tool provided, loosen the two cover screws and remove the cover from the PCVS. Loosen the locking screw that holds the trip rod in place and adjust the rod length, from the end of the collar to the end of the rod, using the dimension determined in Step 9. Tighten the locking screw to 5 in-lbs minimum to hold the rod in place and properly seal the enclosure. Partially close the valve to move the target assembly away (3 to 4 revolutions of the handle/hand wheel). V With the PCVS positioned so the spring will pull the trip rod to follow the target as the valve is closing, slide the PCVS over the nipple. Tighten the socket head screw in the collar. Carefully open the valve to the fully open position. As the target moves to the open position it should engage the trip rod and actuate the switch(es). There should be a minimum overtravel of 1/2 revolution of the handle/hand wheel after the switch(es) actuate (a continuity meter connected to each set of contacts is one method that could be used to determine this). Slowly close the valve. The switch must operate during the first two revolutions of the handle/hand wheel or during 1/5 of the travel distance of the valve control apparatus from its normal condition. NOTE: Small adjustments of the target position may be necessary (consultation with valve manufacturer is recommended). Complete the required electrical wiring, connections and tests. The valve should be operated through the entire cycle of fully closed and fully open to determine the integrity of the PCVS installation and the signaling system. Check that all electrical and mechanical connections are secure. Reinstall the cover and tighten the cover screws to 15 in-lbs minimum to properly seal the enclosure. When the installation and testing are complete, return valve to its proper position. Alternative installation for other post indicator valve housing shown in Fig. 1 and 2. Potter Electric Signal Company, LLC • St. Louis, MO • Tech Support: 866-956-0988 / Customer Service: 866-572-3005 www.pottersignal.com 5401526- REV F • 8/15 PAGE 3OF7 (E)POTTER The Symbol of Protection PCVS Series Control Valve Supervisory Switch Typical Installation on a Butterfly Valve Figs Typical Indicating Butterfly Valve Fig 6 Dresser Indicating Butterfly Valve Valve Partially Closed Valve Open (13 mm) Remove the 1/2" NPT plug from the gear operator case. Loosen the set screw that holds the nipple in the PCVS and remove the nipple. Screw the locknut that is provided onto the nipple. Screw the nipple into the 1/2" NPT hole in the gear operator-hand tighten. Tighten the locknut against the case, to secure the nipple firmly in place Partially close the valve to move the boss on the gear hub out of the way (3 or 4 revolutions of the hand wheel or crank). Using the special tool provided, loosen the two cover screws and remove the cover from the PCVS. Orient the PCVS so the spring will pull up the trip rod to follow the actuating cam inside the valve. NOTE: If trip rod length is excessive, loosen the locking screw and remove the trip rod from the trip lever. Using pliers, break off the one (1) inch long notched section (see Fig. 12). Reinstall the trip rod, tightening the screw to 5 in-lbs minimum, and repeat Step 7 procedure. Remove device from nipple and shorten the trip rod 1/32" (0,80mm) (this is to prevent the trip rod from dragging on the gear hub inside the valve). Tighten the locking screw to hold the rod in place. Re-install the device on the nipple. Tighten the screw in the collar against the nipple. NOTE: In some cases it may be necessary to remove the gear box cover to ensure correct operation (consultation with the valve manufacturer is recommended). Carefully open the valve to its full open position, as the boss on the gear hub moves to the open position it must engage the PCVS trip rod and actuate the switch(es). There should be a minimum overtravel or revolution of the crank or hand wheel after the switch(es) actuate (a continuity meter connected to each set of contacts is one method that could be used to determine this). NOTE: Slight adjustment of gear stops maybe necessary to prevent oveilravel of the trip rod (consultation with valve manufacture is recommended). Carefully close the valve. The switch(es) must operate during the first two revolutions of the crank or hand wheel or during 1/5 of the travel distance of the valve control apparatus from its normal condition. H. Complete the required electrical wiring, connections and tests. The valve should be operated through the entire cycle of fully closed and fully open to determine the integrity of the PCVS installation and signaling system. Reinstall the cover and tighten the screws to 15 in-lbs minimum to properly seal the enclosure. When the installation and testing are complete, return valve to its proper position. Potter Electric Signal Company, LLC • St. Louis, MO • Tech Support: 866-956-0988 / Customer Service: 866-572-3005 • www.pottersignal.com 5401526-REVF • 8/I5 PAGE 4OF7 (E)POTTER PCVS Series The Symbol of Protection Control Valve Supervisory Switch Typical Pressure Reducer Type Valve Installation Fig Nipple / Locknut 1/16" (1,6 mm: Minimum Gap This figure shows the Model PCVS mounted on the valve yoke, with a bracket supplied by the valve manufacturer, to supervise a pressure reducer type valve. NOTE: This application is subject to the approval of the authority having jurisdiction. PBK - Butterfly Valve Kit for Valves with Internal Supervisory Switches Pratt Butterfly Valve Kit as used to mount a PCVS on a Pratt Model IBV Valve. Kits contain: Bracket, nuts and instructions NOTE: Due to changes in valves, brackets may need to be modified by installer. This application is subject to the approval of the authority having jurisdiction. PVK - Pratt PIVA Post Indicator Valve Kit Fig 9 Machine Screw #8-32 Pratt Valve Kit as used to mount a PCVS on a Pratt Model PD/A Valve. Kit contains: Instructions, template, screw and nut. NOTE: This application is subject to the approval of the authority having jurisdiction. Fig Locknuts Botl Lcket and knut Supplied th PBK unting Kit Potter Electric Signal Company, LLC • St. Louis, MO • Tech Support: 866-956-0988 / Customer Service: 866-572-3005 • www.pottersignal.com 5401526- REV F • 8/15 PAGE 5OF7 POTTER P CVS Series The Symbol of Protection Control Valve Supervisory Switch Dimensions Fig 10 2.79 [70,87] [19.61] 01.10 [160.53 [27.92 Rod retracted and breakaway 4.00 [101.60 3.20 [81.26] .85 [21.51 I 0.84 1.52 [21.44 [ [38.61 .12 I [3.os[ 2.72 [69.05 Cover Tamper Switch Rod Fully Extended Socket Head Screw (2)o.886 Knockouts For 1/2" Electrical Conduit Connections Grow 1/2" Knockout Removal oved Fig 11 To remove knockouts: Place screwdriver at inside edge of knockouts, not hi the center. NOTE: Do not drill into the base as this creates metal shavings which can create electrical hazards and damage the device. Drilling voids the warranty. Potter Electric Signal Company, LLC • St. Louis, MO • Tech Support: 866-956-0988 / Customer Service: 866-572-3005 • www.pottersignal.com 5401526- REV F • 8/15 PAGE 6OF7 (E)POTTER The Symbol of Protection Breaking Excessive Rod Length Fig 12 1%1~z- Z, Switch Terminal Connections Clamping Plate Terminal Fig 13 àWARNING An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire become dislodged from under the terminal. Failure to sever the wire may render the device inoperable risking severe property damage and loss of life. Do not strip wire beyond 3/8 of length or expose an uninsulated conductor beyond the edge of the terminal block. When using stranded wire, capture all strands under the clamping plate. All conduit and connectors selected for the installation of this product shall be suitable for the environment for which it is to be used and shall be installed to the manufacturer's installation instructions. For NEMA 4, 4X, 6, 6P installations, the cover screws are recommended to be tightened to 15 in- lbs minimum and the trip rod locking screw tightened to 5 in-lbs minimum to properly seal the enclosure. Typical Electrical Connections Fig 14 EOLR C NC J4M NO NCCOM ris] Noll 11 — M 1 PCVS Series Control Valve Supervisory Switch Ordering Information Stock No. Potter Control Valve Switch (double switch) 1010203 tModel Description Potter Control Valve Switch (double switch). Corrosion 1010211 resistant 316 stainless steel hardware Cover Screw 5490424 Hex Key for Cover Screws and Installation Adjustments 5250062 PBK-S Pratt Butterfly Valve Kit. 3" (75mm) to 12" (30mm) 0090133 PBKM Pratt Butterfly Valve Kit- 1,V'(355 mm) and 16" (406 mm) 0090146 PBK-L PrattButterflyValveKit - 18"(457mm)1o24"(610min) 0090132 PVK Pratt Valve Kit 1000060 -- Optional Cover Tamper Switch Kit 0090200 KBK Kennedy Butterfly Valve Kit 10090143 TBK Tcho Butterfly Valve Kit 10090150 For pressure reducer type valve installation kits (if required) contact valve manufacturer. Engineering Specifications: Post Indicator & Butterfly Valves UL, CUL Listed / FM Approved and CE Marked valve supervisory switches Shall be furnished and installed on all post Indicator and Butterfly valves that can be used to Shut off the flow of water to any portion of the fire sprinkler system, where indicated on the drawings and plans and as required by applicable local and national codes and standards. The supervisory switch shall be NEMA 4X and 6P rated and capable of being mounted in any position indoors or out and be completely submerged without allowing water to enter the enclosure. The enclosure shall be held captive by tamper resistant screws. The device shall contain two conduit entrances and two Single Pole Double Throw (SPDT) switches. The device shall contain a removable 1/2" NPT nipple and adjustable trip rod, the trip rod shall be held captive by a set screw accessible upon removal of the cover. The switch contacts shall be rated at bA, 125/250VAC and 2A, 30VDC. Post Indicator and Butterfly Valve supervisory switch shall be model PCVS-2 manufactured by Potter Electric Signal Company LLC NOTICE Supervisory switches have a normal service life of 10-15 years. However, the service life may be significantly reduced by local environmental conditions. I - TO FIRE ALARM PANEL Potter Electric Signal Company, LLC • St. Louis, MO • Tech Support: 866-956-0988 / Customer Service: 866-572-3005 www.pottersignal.com 150 90012008 1 DESIGNING, MANUFACTURING, 114a$ ;b WI & DISTRIBUTING QUALITY SYSTEMS 5401526- REV • 8/15 PAGE 7 OF 7 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION - _____ • OFFICE OF THE STATE FIRE MARSHAL _____ FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7770-0328:0010 Page 1 of 1 CATEGORY: 7770 -- VALVES/SWITCHES LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, 63042 United States Contact: Bill Witherspoon (314) 595-6900 Fax (314) 595-6999 - Email: BillWpottersignal.com DESIGN: Supervisory switches listed below to monitor pressure, OS&Y, gate, globe/gate, Ply, tank temperature or water level valves. Refer to listee's data sheet for detailed product description and operational considerations. HLS-B WLS-W WLS-S PS-40A PS-120A OSYSU-2 OSYS-B PMS PTS-B OSYSU-1 GVS PCVS-1 PI VS-13 TTS-S TTS-W PCVS-2 WLS PTS-C PS40 PS120 RBVS *P515 *P525 INSTALLATION: In accordance with listee's printed instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation and FM or UL label. APPROVAL: Listed as sprinkler system supervisory switches. - NOTE: Formerly 7738-0328:010 *Revision 09-07-2016 dc r, This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other - - Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division - - - II[(IrI1NL(Ii GENESIS SERIES Pt#q4TIr517 Description: 18 AWG 4/C DIRECT BURIAL FPL Compliance: UL Standard 13 AND 1424; NEC Article 760 Conductor 18 AWG Stranded Bare Copper No. of Conductors 4 Insulation Type SRPVC Color Bik, Red,Ylw,Grn Thickness 0.020" nom. Diameter 0.085" nom. Lay Length 6.0" nom. Jacket Type PVC Color Black Thickness 0.045" nom. Diameter 0.295" nom. HONEYWELL P/N 4157 4C18 E175105 (UL) FPL OR CL2 SUN RES DIR BUR (RoHS) Legend (Ink Print) W/O # XXXXXX-XXX XXXXFT DEVICE/ZONE A B C D E F 1 23456789 Properties Temperature Rating -20 to 60 °C Operating Voltage 300 Volts max. Capacitance 19 pf/ft nom. Impedance 103 Ohms nom. DC Resistance 6.5 Ohms/M' at 20°C Flame Rating UL 1685 Vertical Tray REV A 09/0I10 OA