Loading...
HomeMy WebLinkAbout5980 AVENIDA ENCINAS; ; FA160001; PermitCity of Carlsbad Fire Alarm Permit Permit No: FA160001 5980 AVENIDA Job Address: ENCINAS Permit Type: FALARM Parcel No: 2101701000 Lot #: 0 Reference No.: PC #: Status: ISSUED Applied 1/11/2016 Approved: 1/11/2016 Issued: 1/11/2016 Inspector: Project Title: MIGUEL'S COCINA ADD CELLULAR RADIO TO THE EXISITNG SYSTEM FOR CENTRAL STATION MONTIORING. GSM UNIVERSAL WIRELESS ALARM COMMUNICATOR. Applicant: BAY ALARM COMPANY 4883 RONSON CT SUTE C SAN DIEGO, CA 92111 714-719-9334 Owner: PALOMAR&CO 5850 AVEN IDA ENCINAS #A CARLSBAD CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 317 0 317 0 I • I I I 8205 Ronson Rd. Ste F San Diego, CA 92111 (800) 470-1000 Contractor License # 880138 I. PROTECTED PREMISE -FA ooO ( Miguel's Cocina 5980 Avenida Encinas Carlsbad, Ca 92008 H. MONITORING COMPANY Bay Alarm Company 60 Berry Drive Pacheco, CA 94553 800-470-1000 California Alarm Operating License Number: ACO28 Ill. EQUIPMENT SUPPLIER & INSTALLER 8205 Ronson Road, Suite F San Diego, CA 92111 1(800) 470-1000 Contractor License # 880138 I I I I I I I I I I I I I I Add cellul ar communications to any panel Extend the life and expand the capabilities of older panels by adding the power of advanced. digital cellular communication. With this simple communications add-on, almost every panel can take advantage of revenue-building remote system management and control features. Provide central station communication over cell for any burglary commercial fire or residential fire panel Use Contact ID capture. 4 zones, or Bell Monitoring CellComSLCTM and CeLlComSLCF enables basic remote panel control via Virtual Keypad AppTM Provides end user alerts of arming/ disarming, alarm, and other events Add Z-Wave control of lights, locks, and I thermostats with CellComSLCZTM CELL EkLES Wiring for Ademco ECP Bus Communicates with DMP SCS-I R and SCS-VR Receivers Builds customer loyalty; creates new RMR Armed/disarmed status LED Private labeling available on the rubber logo insert Two outputs Four zones or Bell Monitoring .-, Fully supervised universal alarm communication over COMA Fully supervised universal fire alarm communication over CDMA Program your own account number to easily workaround locked panels Contact ID dialer capture .JEO ON THE APP Video is no Longer an expensive option. With the CeLlComSLC communicators, you can easily add up to six wireless cameras. Via the Virtual Keypad App, end users can do a remote visual survey of their premises to confirm an alarm or simply check in on children or senior adults. Users can also capture still or video images. SPECIFICATIONS Dimensions: 5.5W x 3.75 H x 1 0 Color White Open-Collector Outputs: 2 Zones: 4 Primary Power (CetlComSLC/SLCZ): 12VDC Primary Power (CellComSLCF): 12-24VDC Current Draw: I CERTIFICATIONS California State Fire Marshal (CSFM) - ANSI/UL 1610 Central Station Burglar (Cellular) . ANSI/UL 1023 Household Burglar ANSI/UL 985 Household Fire Warning (CID Capture) ANSI/UL 864 Fire Protective Signaling Systems it It the existing panel supports Contact ID, then it's a candidate for upgrading with the CellComSLC, CellComSLCZ, or CeUComSLCF. There are no issues with lockout codes. Simply add the CellComSL unit to the existing installation and program in your own account number. 'IL 'LARY JiN The CetlComSLC provides control of basic panel security functions and video. The CetlComSLCZ adds the ability to remotely interact with Z-Wave devices, enabling a variety of home automation features including control of lights, door locks, thermostats and more. The CeUCornSLCF offers cellular fire communication on any fire control panel via Contact ID Captures or Zone Inputs. Meets NFPA72 Standard for Single Communication Technology. I It ' S'ERVISED COMMUNICATION Provides a fully supervised alarm communication path for burglary control panels over the COMA network providing higher speeds. CellComSL allows alarm messages to be communicated to an SCS-1 R or ScS-VR Receiver over the COMA network. MOBILE ShGL iR With CellComSL communicators you can • COMA operates on the Verizon network. easily update your older residential and FIELD PANEL UPDATES commercial customers to the latest cellular The Model 400 USB Flash Module allows communication links. With cellular in place, you to easily field update firmware for end users can remotely access their panels panels that would otherwise require the via the Virtual Keypad AppTM. This makes it use of a computer and a Model 399 possible to use their mobile device not only Programming Harness. to control basic arm/disarm functions and receive alerts, but also to control Z-Wave home automation devices for lights, door locks, thermostats, and more with CellComSLCZ. SYSTEM PROGRAMMING System programming over cell via VirtualLinkTM includes zone information and Central Station communications. MULTIPL C CTlON OPTIONS CellComSL communicators can be attached to the existing panel in a variety of ways. It can capture Contact ID messages from the dialer, or connect the four input zones from outputs on the panel; or it can sense the output of the bell of an existing alarm and communicate the appropriate message to the Central Station. FOUR ZONES Each of the CellComSL models provide four zones for connection to burglary control panel outputs. Zone 4 is intended for connection to the control panel bell output. EASY UPGRADE Fl ONLY PANELS Older, dial-up panels have new life with the addition of cellular communication. Earn customer loyalty by extending the life of their existing panels, enabling them to increase the ROI on their system investment and build satisfaction with the purchase decision. BUILD CUSTOMER LOYALTY Avoid the possibility of customers seeking mobile intrusion alarm features from a competitor by enabling those features on their existing panel with a minimal additional cost. They are less likely to switch systems and cancel their contract. When the time does come to replace the panel, they are more likely to rely on you. The app can be branded with your organization's logo and contact information to provide a daily reminder of your services. OUTPUTS Use outputs to connect to an arming zone of an existing panel for control of that panel via the App. '0 B Alarm 210 mA Cellular Standby 210 mA FCC Part 15: MIVCNNO301 ( .' CellComSL CellComSLC Universal Alarm Communicator FCC Part 15 ID CCKPCO159 I ,. CetlComSLCF Universal Fire Alarm Communicator . CeIlC6ffiSLCZ--_._.U,niversatAlarrn Communicator. Z-Wave amok -- I . ...- ,' . - ,r 2503 North Partnership Boulevard 800,641,4232 Springfield. Missouri 65803-8877 Designed, Eng 'erect & Manufactured in Springfield, Missouri CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING jg77 I - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1157:0136 Page 1 of 1 CATEGORY: 7300-- FIRE ALARM CONTROL UNITACCESSORIESIMISC. DEVICES I LISTEE: Digital Monitoring Products2500 N. Partnership Blvd, Springfield, MO 65803 Contact: Terry Shelton (417) 831-9362 Fax (417) 831-1325 I Email: tshelton@dmp.com DESIGN: Models CellComSLC, CellComSLCZ, *CellComSLCF iComSLF, iCOMSL and iComSLZ Communicators. Refer to listee's data sheet for additional detailed product description and I operational considerations and listee's installation instructions for details. RATING: 12 VDC or 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances I and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and ETL label. I APPROVAL: Listed as alarm communicators for use with separately listed fire and burglary alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. Burglary and other non-fire functions were not examined. *Rev. 07-14-15 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PA RSEGIA N, Program Coordinator Fire Engineering Division