Loading...
HomeMy WebLinkAbout6269 EL FUERTE ST; ; FPC2020-0072; PermitE1I1 ripi 11:111 .]I:4I C7city of Carlsbad FiiIreiREr1mLLt Print Date: 01/28/2021 Job Address: 6269 EL FUERTE ST, CARLSBAD, CA 92009-3094 Permit Type: FIRE-Construction Cdmmercial Work Class Parcel #: 2131221800 Track #: Valuation: $1,984,662.45 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Permit No: FPC2020-0072 Status: Closed - Finaled Fire Sprinklers Applied: 04/13/2020 Issued: 04/27/2020 DEV06040 Finaled Close Out: 01/28/2021 Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: PACIFIC RIDGE SCHOOL Description: PACIFIC RIDGE SCHOOL -NEW SPRINKLER SYSTEM (73 HEADS, NEW CONSTRUCTION, 2 STORY CLASSROOMS) Applicant: FPContractor: EPIC FIRE PROTECTION INC EPIC FIRE PROTECTION INC ADAM BOISVERT 765 TURTLE POINT WAY 765 TURTLE POINT WAY SAN MARCOS, CA 92069-8126 SAN MARCOS, CA 92069-8126 (760) 310-6122 (760) 310-6122 FEE AMOUNT FIRE Hourly Services First Hour $159.00 FIRE NFPA 13 System < 100 heads $620.00 Total Fees: $779.00 Total Payments To Date: $779.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov I I I I I I fl88 OO Hydraulics Summary Sheet DashboardHydraullcy Project Information Calculation Date: 2/28/2020 10:16 AM I PACIFIC HIGHLANDS MULTIDISIPLINARY SCHOOL I system ID drawing ref FP-3 6269 EL FUERTE CARLSBAD, CA contract # - Contractor Information EPIC FIRE PROTECTION, INC. 765 TURTLE POINT WAY SAN MARCOS, CA 92069 calculated by ADAM BOISVERT telephone 760-310-6122 fax 760-798-0556 email ADAM@EPICFIRE.ORG :_ —. ......... No. Mfgr Mod SIN# Size K 8 IVICTAULICI ECLH I V3428 1 3/4 8.00 1 1 TYCO I SSU I TY313 1 1I2 5.60 building MD construction Il-B occupancy A-3 authority CARLSBAD FIRE Hydraulics Criteria density .10 GPMIft2 system type WET design std NFPA 13 remote area 1500 ft2 hazard LIGHT spr coverage 20 x 20 ft' sprs flowing 9 figure curve Flow Test static pressure 118.80 psi residual pressure 102.60 psi quantity flowing 2,800.0 GPM date & time of flow test 1-24-20 location of flow test SITE in Suonlv I Demand Granh 118.17 psi available at ca. Ell I I_ 4 ____ - :11 II 4 Im POP ,Ip Id1LiI 075 150 225 300 375 450 525 600 675 Water Flow (GPM) Demand at sprinkler and interior hose flows Total System Demand including Hose Flows at Zero © Copyright 2016 Sigma Development Group, Inc. Page 1 of 5 Dash Hydraulics Supply Analysis HIGHLANDS MULTIDISIPLINARY SCHOOL Sprinkler Flow: 384.OGPM Additional Flows: None Hose Flow at Zero: 100.0 GPM Total System Flow: 484.OGPM Maximum velocity in pipe 13-102 is 22.9 ft/sec Nodes Analysis Minimum Node Actual Node Elev Device KFactor Flow Pressure Discharge Notes ft GPM psi GPM 110 42.32 Sprinkler 5.60 22.50 36.08 33.64 118 42.32 Sprinkler 8.00 40.00 25.00 40.00 117 42.32 Sprinkler 8.00 40.00 25.45 40.36 115 42.32 Sprinkler 8.00 40.00 27.04 41.60 116 42.32 Sprinkler 8.00 40.00 28.55 42.75 113 42.32 Sprinkler 8.00 40.00 29.06 43.12 112 42.32 Sprinkler 1 8.00 40.00 32.34 1 45.49 114 42.32 Sprinkler 8.00 40.00 36.35 48.23 111 42.32 Sprinkler 8.00 40.00 37.30 48.86 0 0.00 Hose@Zero 109.83 100.0 © Copyright 2016 Sigma Development Group, Inc. Page 2 of 5 8388 OO oashb Pipe Information canl Hydraulics ..ANDS MULTIDISIPLINARY SCHOOL From [ El ft evi Pipe ID Flows Added GPM 1 I Inside Diameter I I In Fittings Length C Value Total (Pt) psi I I Notes I I I Fitting ft I I Elev (Pe) psi I To Elev2 Type IFriction Loss I Total Total ft Frict (Pf) psi 108 42.32 1° Eddy Thead 1.0830 1 Len 1.3 Ftg 5.8 c = 120 Pt 118) 25.000 Pe 0.000 Pf 2.848 118 42.32 SG 40.0 0.40163 Total 7.1 107 42.32 11/2 Eddy Flow 1.7280 Len 12.0 Ftg 0.0 c = 120 Pt 108) 27.848 Pe 0.000 Pf 0.495 108 42.32 BN 40.0 0.04127 Total 12.0 Total Pressure at Node 107) 28.343 psi 107 42.32 1" Eddy Thead 1.0830 T Len 1.3 Ftg 5.8 120 Pt 117) 25.448 Pe 0.000 Pf 2.895 117 42.32 SG 40.4 0.40828 Total 7.1 105 42.32 11/2' Eddy Flow 40.0 1.7280 Len 11.8 Ftg 0.0 c = 120 Pt 107) 28.343 Pe 0.000 Pf 1.763 107 42.32 BN 80.4 0.15001 Total 11.8 Total Pressure at Node 105) 30.105 psi 106 42.32 1" Eddy Thead 1.0830 1 Len 1.3 Ftg 5.8 C= 120 Pt 116) 28.550 Pe 0.000 Pf 3.220 116 42.32 SG 42.7 0.45411 Total 7.1 103 42.32 1%0 Eddy Flow 1.7280 0 Len 12.0 Ftg 0.0 C = 120 Pt 106) 31.770 Pe 0.000 Pf 0.560 106 42.32 BN 42.7 0.04666 Total 12.0 Total Pressure at Node 103) 32.330 psi 105 42.32 1" Eddy Thead 1.0830 1 Len 1.3 Ftg 5.8 C = 120 Pt 115) 27.043 Pe 0.000 Pf 3.062 115 42.32 SG 41.6 0.43190 Total 7.1 102 42.32 1% Eddy Flow 80.4 1.7280 0 Len 18.0 Ftg 0.0 C = 120 Pt 105) 30.105 Pe 0.000 Pf 5.842 105 42.32 BN 122.0 0.32457 Total 18.0 Total Pressure at Node 102) 35.948 psi - 104 42.32 1" Eddy Thead 1.0830 1 Len 1.3 Ftg 5.8 C = 120 Pt 114) 36.348 Pe 0.000 Pf 4.026 114 42.32 SG 48.2 0.56776 Total 7.1 101 42.32 jl/U Eddy Flow 1.7280 0 Len 18.0 Ftg 0.0 C = 120 Pt 104) 40.373 Pe 0.000 Pf 1.050 104 42.32 BN 48.2 0.05834 Total 18.0 Total Pressure at Node 101) 41.423 psi © Copyright 2016 Sigma Development Group, Inc. Page 3 of 5 UOO Pipe Information Dashboard Hydraulics ...ANDS MULTIDISIPLINARY SCHOOL From Elevl ft Pipe ID Flows I Added GPM J I Inside Diameter I eter n Fittings Length ft C Value 1 I I Total (Pt) psi Notes Fitting ft I Elev (Pe) psi I To Elev2 I Type Friction Loss [ psi/ft ] Total Total ft Frict (PQ psi 103 42.32 1" Eddy Thead 1.0830 1 Len 1.3 Ftg 5.8 c = 120 Pt 113) 29.057 Pe 0.000 Pt 3.273 113 42.32 SG 43.1 0.46156 Total 7.1 100 42.32 1%" Eddy Flow 42.7 1.7280 __ 2E Len 23.0 Ftg 11.3 c = 120 Pt 103) 32.330 Pe 0.000 Pt 5.815 103 42.32 BN r 1 85.9 0.16959 Total 34.3 Total Pressure at Node 100) 38.145 psi 102 42.32 1" Eddy Thead 1.0830 T Len 1.3 Ftg 5.8 C= 120 Pt 112) 32.335 Pe 0.000 Pt 3.613 112 42.32 SG 45.5 0.50954 Total 7.1 13 42.32 11/2 Eddy Flow 122.0 1.7280 T Len 1.0 Ftg 11.3 c = 120 Pt 102) 35.948 Pe 0.000 Pf 7.170 102 42.32 BN 167.5 0.58345 Total 12.3 , Total Pressure at Node 13) 43.118 psi 101 42.32 1" Eddy Thead 1.0830 T Len 1.3 Ftg 5.8 120 Pt 111) 37.300 Pe 0.000 Pf 4.123 III 42.32 SG 48.9 0.58152 Total 7.1 12 42.32 11/20 Eddy Flow 48.2 1.7280 T Len 1.0 Ftg 11.3 C = 120 Pt 101) 41.423 Pe 0.000 Pf 2.616 101 42.32 BN 97.1 0.21286 Total 12.3 Total Pressure at Node 12) 44.039 psi 100 42.32 1" Eddy Thead 1.0830 T Len 1.3 Ftg 5.8 C = 120 Pt 110) 36.078 Pe 0.000 Pt 2.067 110 42.32 SG 33.6 0.29149 Total 7.1 11 42.32 1Y Eddy Flow 85.9 1.7280 T Len 11.0 Ftg 11.3 C = 120 Pt 100) 38.145 Pe 0.000 Pt 6.968 100 42.32 BN rl.5 0.31260 Total 22.3 Total Pressure at Node 11) 45.113 psi 12 42.32 2%" Eddy Flow 2.7050 0 Len 14.0 Ftg 0.0 C z 120 Pt 13) 43.118 Pe 0.000 Pf 0.921 13 42.32 FM 167.5 0.06579 Total 14.0 11 42.32 2%" Eddy Flow 97.1 2.7050 0 Len 7.0 Ftg 0.0 C = 120 Pt 12) 44.039 Pe 0.000 f 1.073 12 42.32 FM 264.5 0.15332 Total 7.0 © Copyright 2016 Sigma Development Group, Inc. Page 4 of 5 4 8Oo Dashboard Hydramfics Pipe Information ...ANDS MULTIDISIPLINARY SCHOOL From Elevi ft Pipe ID Flows Added Inside Length I C Value (Pt) PSJ I Fitting ft I I Elev (Pe) psi I GPM Diameter in Fittings I I Notes I To ft Elev2 Type IFriction Loss psi/ft Total Total ft lFrict(N) psil 10 42.32 2%" Eddy Flow 119.5 2.7050 2E Len 21.0 Ftg 18.7 C = 120 Pt 11) 45.113 Pe 0.000 Pf 12.137 11 42.32 FM 384.0 0.30557 Total 39.7 3 42.32 21/2 Eddy Flow 2.7050 EIT Len 47.0 Ftg 28.1 c = 120 Pt 10) 57.249 Pe 0.000 Pf 22.941 10 42.32 FM 384.0 0.30557 Total 75.1 2 29.24 3" Eddy Flow 3.3340 2E/T Len 15.1 Ftg 43.5 C = 120 Pt 3) 80.190 Pe 5.668 Pt 6.464 3 42.32 FR 384.0 0.11039 Total 58.6 1 16.16 3" Eddy Flow 3.3340 2E Len 15.1 Ftg 21.0 C = 120 Pt 2) 92.322 Pe 5.668 Pf 3.982 2 29.24 FR 384.0 0.11039 Total 36.1 0.00 6" PVC CL150 6.0900 2T,2E Len 85.0 Ftg 135.6 150 Pt 1) 101.971 Pe 7.002 Pt 0.857 7psilossforDCDAshownas elevation E!11 UN 384.0 Total16.16 220.60.00389 Total Pressure at Node 0)109.830 psi © Copyright 2016 Sigma Development Group, Inc. Page 5 of 5 hI,A7ERI,AL DATA SUBr-117TAL PACFIC RIDGE SCHOOL r-IUL71 -IDI SIPLI N,ARY BUI LDING CARLSSA, CA EPIC FIRE PROTECTION, I NC. 75 TURTLE POINT WAY SAN MARCOS, CA 20 (7GO)310-6122 FAX(70)78-055 Ll tqca Worldwide I Contacts J www.tyco-fire.com Series TY.FRB, 56 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage S General Description The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY-FRB Pendent Sprinkler, where applicable, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 in. (15,9 mm) from the flush pendent position. A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 in. (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-FRB Sprinklers are described in Technical Data Sheet TFP357. Sprin- kler guards and shields are described in Technical Data Sheet TFP780. IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 wromm The TYCO Series TY-FRB Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authori- ties having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Sprinkler Identification Number (SIN) TY313.... Upright 5.6K, 1/2 in. NPT TY323 .... Pendent 5.6K, 1/2 in. NPT Technical Data Approvals Refer to Table A Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar)* * The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Underwriters Laborato- ries, Inc. (UL). Discharge Coefficient K=5.6 GPM/pSi½ (80,6 LPM/bar½) Temperature Rating Refer to Table A Finishes Sprinkler: Refer to Table B Recessed Escutcheon: White Coated, Black Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ............................Bronze Button ......................Brass/copper Sealing Assembly . Stainless Steel w/TEFLON Bulb...............................Glass Compression Screw .................Bronze Deflector ..........................Bronze AUGUST 2018 Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (1Y323) Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon is to be used for recessed pendent installations. TFPI72 2 (50,8 mm) / WRENCH FLATS DEFLECTOR * f- 2-7/8' (73,0 mm) DIA. -H TFPI72 Page 2 of 4 fl Components: * Temperature rating is ** Pipe thread connections per ISO 7-1 1 - Frame 4 - Bulb indicated on Deflector. can be provided on special request. 2 - Button 5 - Compression 3 - Sealing Screw ESCUTCHEON PLATE 1/2 7/16 (11,1 mm) Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN STYLE 15 or 20 RECESSED ESCUTCHEON 1 7/16 (11,1 mm) I NOMINAL MAKE-IN 2' I (50,8 mm) _______ 1/2 NPT** CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT (TY313) AND PENDENT (TY323) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE Installation The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprin- kler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diam- eter of the air bubble is approximately 1/16 in. (1,6 mm) for the 135°F(57°C)and 3/32 in. (2,4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 1/2 in. NPT sprinkler joint should be obtained by applying a minimum to maximum torque of 7 to 14 lb-ft (9,5 to 19,0 N.m). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TY-FRB Upright and Pendent Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 2). With ref- erence to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 lb-ft (9,5 to 19,0 Nm). Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate over the sprinkler threads, and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers 7 to 14 lb-ft (9,5 to 19,0 N.m). Step C. After ceiling installation and finishing, slide on the Style 15 or Style 20 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. / WRENCH RECESS / (USE ONLY FIGURE 2 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W-TYPE 7 RECESSED SPRINKLER WRENCH TFPI72 Page 3 of 4 11 The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installa- tion Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or product manufacturer with any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB Upright or Pendent (specify) Sprinkler, SIN (specify), K=5.6, Quick Response, (specify) temperature rating, (specify) finish, P/N (specify, refer to Table A). Recessed Escutcheon Specify: Style 15 Recessed Escutch- eon with (specify*) finish, P/N (specify*) Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (specify*) * Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 2-7/8 DIA. - (73,0 mm) - 2-1/4 DIA. FACE OF (57,2 mm) SPRINKLER FITTING _ I ___________ FLUSH 3/8±5/16' MOUNTING 5/8 (15,9 mm) (9,5±7,9 mm) SURFACE (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8' (34,9 mm) TY-FRB PLATE 3/4° (19,1 mm) FIGURE 4 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON 2-7/8" DIA. (73,0 mm) FACE OF SPRINKLER - 2-1/4' DIA. FITTING (57,2 mm) 5/16±1/4' 1/2° (12,7 mm) FLUSH (7,9±6,4 mm) / MOUNTING / . J SURFACE// \ (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8" (34,9 mm) TY-FRB PLATE 7/8" (22,2 mm) FIGURES SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON S Care and Maintenance TFPI72 Page 4 of 4 SPRINKLER FINISH (See Note 7) K FACTOR TYPE TEMPERATURE BULB LIQUID COLOR NATURAL BRASS I CHROME PLATED OLYESTERC 135°F (57°C) Orange UPRIGHT (TY313) 155°F (68°C) Red 175°F (79°C) Yellow and 1, 2,3,4, 5, 6 5.6 1/2 in. NPT PENDENT (TY323) ________________ 200°F (93°C) Green 286°F (141°C) Blue 135°F (57°C) Orange RECESSED PENDENT (TY323) Figures 4a and 5b 1,2,3,4 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green Notes: I. Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the City of New York under MEA 354-01-E. VdS Approved (For details, contact Johnson Controls, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-54-428-3377.) Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. Installed with Style 15 (1/2 in. NPT) 5/8 in. Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20 (1/2 in. NPT) 1/2 in. Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). TABLE A LABORATORY LISTINGS AND APPROVALS FOR 5.6 K-FACTOR SPRINKLERS P/Na77_XXX_X_XXX SIN SPRINKLER I I TEMPERATURE I FINISH I I I RATINGS I NATURAL BRASS PURE WHITE (RAL9010)a POLYESTER SIGNAL WHITE (RAL9003) POLYESTER JET BLACK (RAL9005) POLYESTER 9 CHROME PLATED Notes: a. Eastern Hemisphere sales only 135 135-F (57-C) 155 155-F (68-C) 175 175°F (79°C) 200 200°F (93°C) 286 286°F (141°C) 370 I 5.6K UPRIGHT (1/2 in.NPT) I TY313 371 1 5.6K PENDENT (1/2 in.NPT) I TY323 Notes: a. Use suffix "I" for ISO 7-1 connection; for example, 77-370-4-175-I TABLE B SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION 1400 Pennbrook Parkway, Lansdale, PA 19446 ) Telephone +1-215-362-0700 401 C 2018 JohnsonJohnsonCnt,ola. All rieh*s ,ese,°ed. All poifloatln ,,d athe, of800atlon shown we,e crrnnt as at dooamnnt renision date and aresobleot toohat,gs wltheat notlo,. Johnson NATIONAL FIRE PROTECTION ASSOCIATION and NFPA we ,eulsv,nd vden,o,I,o of Nellonol Fire Proleclion Aa,wiatiofl Controls TEFLON in a ,egislared tn n, adea,I, & QuPnt Jcxtaulicr 40.78 Technical Specifications: Models: V3428 Style: Extended Coverage/ tight Hazard - Pendent, Recessed Pendent Nominal Orifice Size: %'/14 mm K Factor: 8.0 Imp./11.5 Si.' Nominal Thread Size: VV NPT/20mm BSPT Max. Working Pressure: 175 psi/1200 kPa Factory Hydrostatic Test: 100% 0 500 psi/3450 kPa Mm. Operating Pressure: 7 psi/48kPa Temperature Rating: See chart For K'Fovtor when preserve A nones/nrA in Oar, multiply SI. units by 10.0. Exaggerated for clarity APPROVALSILtSTINGS madell 088co Size 6-he, 17/ 2' L J?t QJmpd Nommnelg panel Nominal K Factor SI.' _Rnw—mme— 11.5 Quick [ 11.5 Quick Deflector Type Approved lAnrperature Ratings F'/C' Pendent jRecessed Pendent Approved Temperature Ratlirgo FIC' ac zULus —_T_ ts5'F,6O'cFiy/68c 200'F/93C J ——o--- MLC 200 /93"C Listings and approval as of printing. Not all temperature raring combinations are Approved or Listed. Check VAlerIe for eprvlfio combinations. For K-Footer When press/re A vane/red In Oar, multiply S.I. writs by 10. Light haeard only. 21A760 Max.He lb 11/0/48 mm Flnbh~d Su,f— mm 4rMI 40.7e 8456 Per A Updated 01/2015 02015 Viotaln Company. All rights n500rnnd. victaulic.com 2 '4xtauiict victaulic.com I Sprinklers I FireLock° I V34, K8.0 I Publication 40.78 Material Specifications: Accessories: Pendant Deflector: Bronze per UNS C22000 Installation Wrench Bulb: Glass with glycerin solution 0 Open End: V34 Bulb Nominal Diameter: 0 Recessed: V34 Eln,,,.0 Res ..,...,,.'an...... Sprinkler Finishes: Load Screw Bronze per UNS C65100 0 Plain Brass Pip Cop: Bronze per UNS C65100 0 Chrome Plated Spring: Beryllium nickel 0 White Painted Seat: Teflon' tape 0 Custom Painted Framer Die cast brass 65-30 0 VC-250° Lodgement Spring: Stainless steel per UNS S30200 Teflon A a registered trademark of 5opon1 Co. UL Listed and FM Approved for corrosion resistance. Approvals/Ustirigs: Dimensions: FireLock® V34, K8.0 Model V3428 Quick Response Extended Coverage/Light Hazard (ECLII) Pendent and Recessed Pendent A4spmveWLIstingro um Sn, Viola/ho Fob otno 10,01 in, 0010 AnriIn Product Description: These Model V34 ECLH sprinklers are designed with a K8.0 orifice size and provide added coverage at normal light hazard operating pressures. Each sprinkler is cast with a hex-shaped wrench boss to allow easy tightening from many angles, reducing assembly effort. This sprinkler is available in various temperature ratings (see chart on page 4) and finishes to meet many design requirements. Coverage Extended spray coverage is up to 400 square feet (37.2 sq. m) per NFPA 13. joblOwner - - Engineer 1 I [Spec Section Location Paragraph Contractor [AsoPreveri Submitted By L! victaulic.com I Sprinklers I FireLock I V34, K8.0 I Publication 40.78 40.70 8496 Pan A Updated 01/2005 e 2015 victorIA Company. All rights reserved. Sprinkle Pe4rFAnd ______ ----.----J Roorn Sin Flow Rate End Sprinkler Pressure GPMLJLPhI PSI/loPe --;--- ---;,;:---- Or s in 56 16016 10.6 4904.9 90 73.1 18015 33 17.0 2.5 05.5 125 117.2 20020 40 25.0 6.1 06.1 150 172.4 victaullc.com I Sprinklers I FireLock° I V34, K8.0 I Publication 40.78 Room Size: L I Taoimsm Sprinkler Victaulle Nominal Ambient Glans Temperature Classification Part IdentlIlcatlon Teerpeeklsore Temperature Rating Allowed Bank Cooler [ Ordinary A 135°F/57°C 100°838°C orange Ordinary C 103°F/68°C100°F/30°C Red Intermediate I 175°F/79°C jjfsoc Yellow IntermediateL± h2000F 55°F/65°C Green victaulic.com I Sprinklers I FireLock° I V34, <8.0 I Publication 40.78 Ratings: All glass bulbs are rated for temperatures from -65°F (-54°C) up to those shown in adjacent table. Diottibution Patterns: Models V3428, KS.O ECifi Pendent and Recessed Pendent Distribution Patterns - Trajectory 0' 4' 0' a'1 p is 11 16 ia Okn Ian, tern 500 5am Sir, atm 4/0 15m F Respersian Fatfirrelass J Minluimim io.tatallsn Spacing [113f-Criilck . NOTES A. Data shown In oyproclrnure and an very duo to differences In installation. S. Thnsngopfo iboevir apprndrrafe bolnetoren, Borunnttin ordnoi'nenttlng patrons for these eperfntocrauio riretosh uurorrSsrin 0prmktnrs. They am pronidnrlon irterrrwtion lot gsldarreo in amldirrgebnlrsonioru intipinklins end should not be used as minimum sprinkler spacing odes for IretoltutIrn. Refer to One appropriate nFPA National Fire Coda M. Authority Hoeing Jsiloftirion for spas/h Inlorerorion regarding sbnlrooAons, sparing lirrrirotiru and ores of coverage requirements. Failure tolsitre Irene gudeilnon could udonronly sliest Are pnrlorrrorrse of the sprinkler and 554 yeA all listings, Opprovak and Warranties. C. All porfnrrrs are ayrnnretrlcal In the enntrrfne of the warorwey. 40.70 0490 Rev A Updated 01/2015 0 2015 Vctushs Company. All rights reserved. victauliccom 3 Available Wrenches: Open End Recessed Pendant V34 L V34 Recessed Pendent - L Always rood and understand Installation, corn, and eralutenotwe Instructions, supplied with each bun at sprin- bier., before proceeding with Installation of any sprinkler.. • Always wear safety glasses and foot protection. Depressurize and drain the piping system before attempting to Inatall, renown, or adjust any Victatile piping products. Installation min, especially those governing abstraction, most be olttctty followed. Pointing, ploting, or any re-coating of sprinklers Collier than that supplied by Victaslc) is not allowed. 0 Failure to follow these ksotrsietisnn could result In nenl000 personal injury and/or property damage. The owner Is responsible for maintainIng the lire protection system and devices In proper operating condition. For minimum maintenance and Inspection reqslrenmoto, refer to the current National Fire Protection Association pam- plitet that describes we and maintenance 01 sprinkler ayatnnu. In addition the authority loaning jurisdiction reef have additional nmmotenonce, testing, and Inspection requirements that moot be followed. If you and additional copies of this publication, on It YOU have any question, about the safe installation of this product, contact itictaullc World Headquarters: P.O. Boo 31, Easton, Pennsylvania 18044-0031 USA, Telephoner 001-610-559-3300. - - !n050ttutOe Note Reference shootS dews be node Winn ,.rriy5tarrlic Firsivoy AutomatS Sprinkler. ins prodost shod so mururrerured by Vistauts or to 61010016 ,prslrlsollorrs. All pro/onto tr,ncslletre at Mrkdern.-.n Storer snttr/itorrfur,rynr,ernlrelaona. This krernllctno sheer to hr lrrstroed Sr 00W/arGo with currerri PorouS llrsralierionia,00mble brslrUsllorra. A cstuded c/h rush crriperasrorVoraLao p1000250 fri soeAs5 leslollutior red r.semSy VIrI000r —a—Ore /hhf 5r0trrn. rmolactnpoti&roflere, drotirSo ourS stoonerd Asia, sod AaViau8r lrr POP brrnsr on our orb/heel 5feb01 5.000. sqdpnmntnlOnutnsvcnondolrnoutl010,rYec5gorlsns, w000sr9 Tra.st. Rotor to elm Warranty senior of t1he curr.nt Price List or conrad 5000000 for details. Vistrulls iso retlsrarnd trsdrmnrk of Vistoulls Company. 'J 40.70 8496 tee A updated 01/2015 0 2016 Vbfaulis Company.Al rights reserved. victauliccom 4 TFPI76 Page 2 of 6 DEFLECTOR l-Frnrrry HAT 2 - Button 3 - Svaling Assembly 4 - Bulb 5- Compression Screw 6 - Dellector" 6" 4 2 3 9/16' WRENCH 1/2'"' (14.3 mm( FLATS NPT 1-13/16' 7/16' 146.0mml I lilt mm( 0 CENTERLINE NOMINAL OF SPRINKLER MAKE-IN WATERWAY L 11/2' (30.1 mm) ESCUTCHEON PLATE SEATING ________ 2-3/I6' SURFACE STYLE 10 or 25 RECESSED ESCUTCHEON * Temperature rating is indicated an Deflector Pipe thread convections per ISO 7-1 can be provided an special request ALL FINISHES EXCEPT POLY-STAINLESS DEFLECTOR I - Frame HAT 2 - Button 3 - Ovally9 Assembly 4 - Bulb 5 - Compression Screw 6 - Deflector* t 4 2 3 9/16' WRENCH 1/2' )14.3 mm) FLATS NPT elm 1-13I16' 7/16' (46.5 mm) I lit i rent) CENTERLINE I NOMINAL OF SPRINKLER MAKE-IN WATERWAY L (30.1 mm) ESCUTCHEON PLATE SEATING ______. 2-3/16' SURFACE (55,6 mrn( STYLE 15 RECESSED ESCUTCHEON Temperature rating is indicated on Deflector 2-7/fl DIA. 0 (73. vanl POLY-STAINLESS FINISH ONLY FIGURE 1 5.6 K-FACTOR QUICK RESPONSE SERIES TY-FRB HORIZONTAL SIDE WALL (TY3331) SPRINKLERS Woridwide I tjifJ Contacts www.tyco-frre.com Series TY-FRB - 56 K-factor Horizontal and Vertical Sidewall Sprinklers Quick Response, Standard Coverage General Description The Series TY-FRB, 5.6 K-factor, Hori- zontal and Vertical Sidewall Sprinklers described in this data sheet are quick response -standard coverage, dec- orative 3 mm glass bulb type spray sprinklers designed for use in light and ordinary hazard, commercial occu- pancies such as banks, hotels, shop- ping malls. etc. They are designed for installation along a wall or the side of a beam and just beneath a smooth ceiling. Sidewall sprinklers are com- monly used instead of pendent or upright sprinklers due to aesthetics or building construction considerations, where piping across the ceiling is not desirable. The recessed version of the Series TY-FRB Horizontal Sidewall Sprinkler is intended for use in areas with a fin- ished wall, It uses a two-piece Style it Recessed Escutcheon with 1/2 in. (12,7 mm) of recessed adjustment or up to 3/4 in. (19,1 mm) of total adjustment from the flush sidewall position, or a two-piece Style 20 Recessed Escutch- eon with 1/4 in. (6,4 mm) of recessed adjustment or up to 1/2 in. (12,7 mm) of total adjustment from the flush side- wall position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fined pipe nipples to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal-lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 6 of copper alloy sprinklers beyond that which would otherwise by obtained when exposed to corrosive atmo- spheres. Although corrosion resistant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suit- ability of these coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. CMM The Series TY-FRB Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authori-ties having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main-taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac-tor or product manufacturer with any questions. Sprinkler Identification Numbers JULY 2018 Technical Data Approvals UL and C-UL Listed FM Approved LPCB Approved NYC Approved Maximum Working Pressure Refer to Table B Discharge Coefficient K=5.6 GPM/psi"° p0,6 LPM/ba15101 Temperature Ratings Refer to Table A TFPI76 Finishes Sprinkler: Refer to Table C Recessed Escutcheon: Signal or Pure White, Jet Black, Grey Aluminum, Chrome Plated, or Brass Plated Physical Characteristics Frame . ..... ..................... .eronva eumtav . .....................6monn/coppvl 500live Aruombly. .tvrylliumv Nickelw/TEFLDN 8.1r. ......................... .... .310*1 Compression 5croa ................Brovmn HOW Sutivslom ............ .... .... emunu: SOW 0etuvmor.... ........ ......... Copper Poly-Stainless Physical Characteristics Frame ............................tranve Steel' cUb ...............................Gras Camptnsixv Saryw.. ... LGB steinleee Steel' tfSW Deflector ..............Coppor/orvvvv Seeding Axsembly,30td Plsted eeryllium Nickel wITEFLON 'rvpe Late otHyleme Steel 1U55 3r6051 po,001M ureUntMms5LssreWNLra. Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The Series TY-FRB, 5.6 K-factor, Hor- izontal and Vertical Sidewall Sprin- klers are intended for fire protection systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 10 or 20 Recessed Escutcheon. as applicable, in to be used for recessed horizontal installations. (Refer to Table A for complete approval 1Y3331 ............. ...Horizontal information including corrosion resistant TY3431 .................. Vertical status.) TFPI7B TFPI76 Page 3 of 6 Page 4 of 6 Installation The Series TY-FRB, 5.6 K-factor, Hori- zontal and Vertical Sidewall Sprinklers must be installed in accordance with this section. General Instructions Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 in. (1,6 mm) for the 135"F (57"C) to 3/32 in. (2,4 mm) for the 286"F (141"C) temperature ratings. A leak tight 1/2 in. NPT sprinkler joint should be obtained with a torque of 7 to 14 lb-ft (9,5 to 19.0 Nm). Higher levels of torque may distort the sprin- kler and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuf-ficient adjustment in the escutcheon plate by under-or over-tightening the sprinkler. Readjust the position of the sprinkler fitting IS suit. Series TY-FRB Horizontal and Vertical Sidewall Sprinkler Installation The Series TY-FRB Horizontal and Vertical Sidewall Sprinklers mast be installed in accordance with the fol-lowing instructions. Step 1. Horizontal sidewall sprinklers are to be installed in the horizontal position with their centerline of water- way perpendicular to the back wall and parallel to the ceiling. The word "TOP" on the Deflector into face towards the ceiling. Vertical sidewall sprinklers are to be installed in the pendent or upright position with the arrow on the Deflec- tor pointing away from the wall. Step 2. With pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 5), With reference to Figure 1 or 2. the W-Type 6 Sprinkler Wrench is to be applied to the wrench flats. * Temperature ** Pipe thread rating Is connections indicated on per ISO 7-1 can Detlector. be provided on special request. Series TY-FRB Recessed Horizontal Sidewall Sprinkler Installation The Series TY-FRB Recessed Horizon-tal Sidewall Sprinklers must be installed in accordance with this Section. Step A. Recessed horizontal sidewall sprinklers are to be installed in the hori- zontal position with their centerline of waterway perpendicular to the back wall and parallel to the ceiling. The word "TOP" on the Deflector into face towards the ceiling. Step B. After installing the Style 10 or 20 Mounting Plate over the sprinkler threads, hand tighten the sprinkler into the sprinkler fitting. Step C. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 6). With reference to Figure 1. the W-Type 7 Recessed Sprinkler Wrench is to be applied to the sprin-kler wrench flats. Stop 0. After the ceiling has been installed or the finish coat has been applied, slide on the Style 10 or 20 Closure over the Series TY-FRB Sprin-kler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The Series 'rY-FRB, 5.6 K-factor, Hori- zontal and Vertical Sidewall Sprinklers must be maintained and serviced in accordance with this section. Before cloning a fire protection system main control naive for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be Obtained from the proper authorities and all personnel who may be affected by this action must be notified. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible Signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or other- wise altered after leaning the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprikiers 5/0*1/4" 115.0*0,4 mm) MOUNTING FACE OF SURFACE SPRINKLER FITTING VA CLOSURE 2-7/8" OW. SERIES l3.0 mm) TY-FRB 2-1/4" 05. ,. MOUNTING (57.2 1 mm) PLATE ! 13.2 mm) 1-1/4" 131,0 mml 3/4" (19,t mon 3/4"ltn.1 mml 1/4" 10.4 mrnl FIGURE 3 SERIES Th"-FRB RECESSED HORIZONTAL SIDEWALL SPRINKLER WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON t/2s1/8" - (12,7*3,2 mm) MourririNG FACE OF SPRINKLER SURFACE FITTING VIAL CLOSURE 2,7/at SERIES -I/4" DIA. 173,0 mm) TY-FRB lsl,2mrr( MOUNTING PLATE mm) 1-1/4" 131 1 t/4"(0,4mm) FIGURE 4 SERIES TY-FRB RECESSED HORIZONTAL SIDEWALL SPRINKLER WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON - Frame 4 - Bulb 7 - Ejection 2 - Button 5 - Compression Spring 3 - Sealing Screw Assembly 6 - Deflector" ARROW MUST POINT AWAY 7/16' FROM AND BE ESCUTCHEON 111.1 mm) PERPENDICULAR PLATE STING NOMINAL TO THE BACK 6" SURFACE 1,"2""" MAKE-IN WALL SURFACE NPT LOW S 23/16" TL 2 31ti: (55,6 mm) 30.1 mm) FLATS WRENCH SHOWN SHOWN CROSS PENDENT UPRIGHT SECTION FIGURE 2 5.6 K-FACTOR QUICK RESPONSE SERIES TV-FRB VERTICAL SIDEWALL (TY3431) SPRINKLERS WRENCH RECESS lEND "A" USED FOR ljio~1/2" NF1' MODELS) FIGURES W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS A;3 PUSH WRENCH INTO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 6 W-TYPE 7 RECESSED SPRINKLER WRENCH TFP17B Page 5 of 6 SPRINKLER FINISH (See Note 11) K TYPE TEMP. BULB NATURAL CHROME LIQUID BRSS I PLATED POLYESTER° POLY- LEAD STAINLESSO COATED 1350F (57°C) Orange 155-F (68-C)Red riontz. 1750F (79°C) Yellow SIDEWALL 1,2,3,4,9,10 1.2.3,9 1.2 1.2.3.9 (1Y3331) 200°F (93°c) Green 286'F (141-C) Blue 5,6 RECESSED 1351` (57°C) Orange 155°F (68°C) Red 1/20. HORIZ. NI°T SIDEWALL (TY3331)0 1. 2,4,9. 10 1.2. 9 1,2 N/A 175F (79°C) Yellow Figure3 2000F (030C) Green RECESSED 1350F (57'C) Orange 155°F )880C) Red HORIZ. SIDEWALL 1, 2,3, 4,9 N/A N/A 175°F (79°C) Yellow (TY3331)° Figure 4 2050 (930C) Green VERTICAL 135W (57'C) Drone 155W )680C) Red 15. SIDEWALL 175W )790C) Yellow 6/2 in. Installed 5,6,7,8,9 N/A 5.8.7,9 Nl'l' Pendent 200°F (93°C) Green or Upright 286°F (141°C) Blue NOTES: 1. SOled by and01010ters Lsboevlvojes. too. lUS waoCk I10000rse opn,r,klere 01r00 In Slant sfl4010ireny Ha00r0 Oc ,00nnvi055t,I4 tory in (100003000019 tOP Of 0,10 callIng dIstance. U. Solve by afldvne.rltoro 105000ncrien two, 000 in 000ooeld'U14 000006 600p0050 Sprinkled Ian I've 8 Light Ind Undinoty IIeven000paociabols4 to 14. in. 11000 InAnIty lop or 00000101 Iv 101iro 2010005. approved br Factory M,,toal Maccatch Conponobon IRvI 5000,00 005pvflsv Si to, sob Ugflt Hazard nooUp,0tcjve 00 ad 010 In. 110010 000 -4M, olt103evlo, no 0011109 0001,01. Approved by 11,0 Cones Pl000flvOflCvtllljptntior Hoard lt.PCO Oat. So. 000/003 0104100 nfl, 11000150 IfitnI top at de00our no voiptrnJ d000000. The LOG does rot nate the h. 0. Snored Ct li,,dawn,una Loi,olaivtioa. lno.aa d,,iok 11.1p.—Sell,, Flora nol000i,, rl Ohl ,l,vt OndinOfit 1102.0,0 000000,,H,05, o Liolvd by 400vn'coritvna Labvn,,lonieo 011(00,, Cnra,Io (C-UL))vs Q-000pvn,01 80,0101.00 on Use 10 Light cr10 dtd,r.a,y Havana 0000perloeo. 0. dppnvveltbvpaotonyeoiool 855101chCvnpanst;or7oyas Quick veepvr,ehpn,nhtars in, oaaln Light evve000vopanolp, 0- Approved byoflv boo. Pn000rtivv cenb000tbvr P.0004 ILPCO Hot lv 000000 &0010fvol 05000106 Response vpnirhlono. App—lid Infill 13-11101 Alf. ad 01 e 14 1 U (100 in 150 1,101100 If F LP 0 0 8 or Ofloto Palyeotar CoaSd 0114 1.011 Goalolt spnnkons ala notvd lv be US and C- UL 1604, Ifla opoinklens any ULvnvtC.US Lbo,000 001tvbbvv 000151000 SPniflfljvns. Wflvnv 1004 Coonvu SpyllklotS ore noted lv be lMoppn000d. In. 50050cr. Ore FM Upp0000d as COr,Oebvv t105,00001Spoirkiv,a. a IrotaIle400:lfl Slob tO Ill? ii NFl 10/4 ,fl:tvtvladp;stmort ItaHeaCed l5000flvvfl 01 105101104 10:18 $101. 20 7/4 nfl. Neil r/2 in. floral Ad000lnnnevl IOao0aevIl p3101ohavfl. Ftlnflleen(0defl000, 000. TABLE A LABORATORY LISTINGS AND APPROVALS TFP176 Page 6 of 6 SPRINKLER FINISH K TYPE NATURAL BRASS CHROME PLATED I POLYESTER LEAD COATED HORIZONTAL SIDEWALL lTY3331l 255 PSI (172 BAR) or 175PSl (t2,1 BAR) R CESSED HORIZ. E 1 513 SIDEWALL lTY3331) (SEE NOTE 1) VERTICAL SIDEWALL 175 PSI (12,1 BAR) NOTES; I T. flnavl,naorn oavlhtna 0100001, of 210 polIty.? 5a9 orry 0P1000 10180 LionO 1, Lin r, Labv,ei001s. Inc 10114. 03,5 COoing 0, Und000rnlvra t.000,soyoa. In,,. Icr oo In Pon,0,fla 10 -ALl: dId. 11,c /opp,ovol ho IOU 031 01 Nsa Vail, TABLE B MAXIMUM WORKING PRESSURE PIN 57 - XXX - X - XXX I SPRINKLER TEMPERATURE FINISH [""Ij RATINGS 1379 HORIZONTAL SIDEWALL TY3331 1 NATURAL BRASS 135 135'F(57°C) 375 VERTICAL SIDEWALL T03431 - POLY-STAINLESS GREY 155 5.F(uaec( 2 ALUMINUM )RAL0057)1 - POLYESTER PURE WHITE (RALg010(2 175 POLYESTER - SIGNAL WHITE )RAL9053) 280 POLYESTER 286 175-F (79-C) 200W )93°C) 286°C JET BLACK )RALBSOS)° POLYESTER 7 LEAD COATED 0 CHROME PLATED NOTES; (341°C) I. 005ileblo Ivoivro3l erIe. 0. Fsvorntloflniept,erfi 0,115 vOl. I uuailbblo in, floor- iee'ei 012000:103',, tanrparalu,o laden OlIn. TABLE C PART NUMBER SELECTION SERIES TY-FRB HORIZONTAL AND VERTICAL SIDEWALL SPRINKLERS damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprikler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprin- klers, after the installation has been completed, to verity the integrity of the corrosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of inspecting from the floor level, a random sampling of close-up visual inspections should be made, so as to better determine the enact sprin- kler condition and the long term integ- rity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or product manufacturer with any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Number (PIN). Sprinkler Assemblies with NPT Thread Connections; Specify: Series TY-FRB (specify SIN), (specify K-factor). (specify) Horizontal Sidewall or Vertical Sidewall Sprinkler, Standard Response, Standard Coverage, (specify) temperature rating, (specify) finish or coating, P/N (specify from Table C) Recessed Escutcheon Specify: Style (10 or 20) Recessed Escutcheon with (specify*) finish, P/N (specify*) 000511010,1,1,0001001,1Shell r00010 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, PIN 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 5000 Peor5000 Pepkaasy. Caredete. PA I0900ITeIaet,one ,l.zvS.gnp.orao /)J '° Johnson / Controls a As the leading suppier of steel sprinkler pbe. we understand that there we no second chances in fire suppression. You need products of enduring quality and exceptional strength-plus reliable service. You need Bull Moose. Bull Moose in Fire Sprinkler Pipe Product __ information 0). (in) 1.660 1.900 2.375 1 2815 3300 1 4.500 10. (in) 1.530 1.728 2.203 2.705 3.334 4.310 Empty weight (Ib/ft) 1.222 1.844 2.330 2.009 3.351 4.968 Water Filled "eight (lb/ft) 2.019 2.850 3.982-- 5.299 7.144 11.290 LRR. 1.98 3.44 2.78 1.65 1.00 tOO - Pieces per Lift 61 51 37 30 19 19 - Lift Weight(R]s)21lengths 1.555 2.362 1810 1.77-o-T 1.341 1.982 Ult Weight (Ins) 24 lengths 1.739 2.700 2.069 2.022 1.533 2,265 Lift WEight(Ibs)25'Iengths 1,864 2,812 2.155 2.101 1.596 2,360 EDDY FLOrJ AVThES: . UL listed (US &anada) and FM approved ASTM A135 and A795 Type E. Grade A Certified Complies with 1FPA-13, 13R and 14 . Industry-leading hydraulic characteristics CRR of 1.0 and greater I. All pipe NDTw31d tested :OTHER ITS/SttES: We have the most stocking locations in the industry, for best delivery and availability Plain end or roll groove Eddy Guard II" bacterial-resistant internal coating Custom length options . Hot dipped galvanization Reddi-Pipe® red or black pipe eliminates field painting Compatible for use in wet dry, preaction and deluge sprinker systems The only maker with EPDs (to help earn LEED points) 14'1 1 ONFSA NFFW As the leading supplier of steel sprinkler pipe, we understand that there are no second chances in fire suppression. You need products of enduring quatity and exceptional strength—pls reliable service. You need Bull Moose. Bull Moose Fire Sprinkler Pipe Product Information !MUIIi . 5 LU lengths EDDYTIREAD 40 iITh5: UL Listed (US & Canada) and FM approved ASTM A135 and A795 Type E. Grade A Certified Complies with NFPA-13. 13R and 14 Industry-Leading hydrauLic characteristics CRR of 10 and greater All pipe NDT weld tested EIIive makerofIi'ë'diIiiW® - 4J19 I k I 1Iij:l OTHED BENEFITS/SERVICES-.. We have the most stocking Locations in the industry, for best delivery and availability Plain end or roll groove Eddy Guard ir bacterial-resistant internal coating Custom Length options Hot dipped galvanization Reddi-Pipe® red or black pipe eliminates field painting Compatible for use in wet dry, preaclon and deluge sprinkler systems The only maker with EPDs (to help earn LEED points) () 4 - tqco I Fire & Building I I Products I Technical Services; Tel: (800) 581-9312 / Fax: (800) 791-5500 I wwwtyeo-tlre.com I Grinnell Grooved Fire Protection Products Figure 772 Rigid Coupling - Patented General Mouslog: Ductile iron conforming to Should be contacted relative to any questions. ASTMA-5* Grade 65-45-12 eaybnpainrnent must belrnmedlatetycnrrected. Description Peoteetiss Ceatlngo: It is recommended that automatic sprinkler Non-lead orange paint systems be lnepected,tosted.and maintained by Fine brigade rod (optional) non-lead paint a qualified Inspection Service. lent dipped galvanized conforming toaSTM A-153 Limited Bott/NStL Track Head Bolts - conforming to Warranty PalM A-lBS. Zinc Ptated, (Mm, Tensile - n10,000 poW758422 kPa) Products manufactured by TycoBra Filokis are Metric - conforming to AST F566M aensiHesctwijtaSernotBpaentint3t)15)ycers Oee Fee Protection Qaskal: (specify when ordering) tiistdele2sinnxterteaiseeatolraPaipwton1 aubmr000 Street for • Grade A EPDMA violet color cede lonawipnopertyttioaHeadndetra(lennratrot Pressure ReOng and uutosiapprsoai loatHe amblomtov150(e6C)tonhreprnlec5on useardseavlof.lplewenslye.leatthoee)10)yceen systems. Not recommended for Set water from data of ttlttanrelt by Tpor Ike Products, No um772RigidCautt6ngpmvt60aigrd)eintbp systems. warranty b given for products or components 0nn Goppmg al- the Otd8Th at He PL • Trinsoai(GmdeEEPOM),gmmcOtorcode nrerakiareIbugrenHeHeaifiteNobyaaoeco pioneers. 6158 watoigs are parferraff thY pipe for use in vito pipe or freezer systems. wtihhycoteepdrctonelsaaiwrtinelerts and freezer aplkadees Figure 772Rigid CraiPlnpa • Protubitcatod (Grade "K EPOMA) vAde,tomkiiroAaIantt58rgnpaantPahan, amaptoeendFionokthttott01ul)le0k0 Pipe lad (See Dots Olteot TFP18fi5 for old In setootlog mmcoxtiOralr8treserdeoarn'mdsNojr8kSekre arvaenemsnetsi9vetowdethtlomtkrgor proper 800kot) n01toet an iqderot Er amsoteaco with apethable vstingtsnges.11krapab105tprmaaem5pt0565gne5 Standards ci the National Pin Prclen5mi Association )3447EPa)endilganpipeobeardeefllhtesiwa when used in fire pmlodivinservices, Ordering king kokottal. I60rk found! by Tyco tire 61gidCewttommomsrotsdor8yptpeaot Procedure kitots to be ltel&Bee viral to wiles retained an ttnorsrggettrstimo. rngaiTycoIknPrretiokmthcleHer. TysoIko When placing an ender, Indicate the tell product rindlctcoommquPBacooriamem The Rgzov 7721115W Coupling descr/bed bomb name.Pleasespecltytheqaantity,figarenumber, mioilesinsnailneixvdrna/ntaimred!ncompiiarrmerth type of gasket, GmdeW EPOMIs0 Prelubmlcatod Hearte of protixas on pats of products lyre Pie othdoconnmtiesawiboeitthteawkablesthrsthmtth )GradeKEPOMA)onGmdeEEPDMT/-Seai, pasiaBncihetoroploksyctan oftyofltitivno/Fmnysotecdsrnnnadettiln.!ra681/on and raze. design enomarimaraoaiasnirwrgwilvstornnalivn to The storolortte Of any' other aobmrellfln hooting G/mnotGroovs1Ptpin4)Prraktyvatvestes ropeeeanbokou jurIsdiction. Folders to do so may lm,real, tile and ether prottar,ts are asodettle thmsgtraed the IN No 65091 SHALL TYCO PBS FRCOIItS 88 pelfoml000eotthdoefoalce. U.S.,canaith and intomatineonly, through anetwork LIABLE IN CONFIRACT, MR, SrRKN UAKRgg The owner is ranponnth&r Sr nra/mtbiitlrqi flwir Sin ol distribution centers. You may write dkecOyoncat protective system and ubondn tln proper operatklp 215-362-d709 for the rtistrltajton nearest you, tNolPECr,SCeL0atde58r0 conyWon. The looteltbng mnhracbor or Sprinkler ngi817900,erofwldberze7&Etadur1t/eamygmim/iorsc Care and FWIARDUISS WIStitOtPAED6toltTlfiEF1ZISl8Lt1YEPSLEH Technical Maintenance IN No tocel 560± ThIS) ARE The exeter Is responsible for the Inspection, PRODLCMLPBUfYDEEIDANAMOLINTEDUAL Data testing, and maintenance of their fire protection ioytnts0t.09opiTh Figure: 772 system and devices In accordance with the WAML$ffffhUffNLEUADF glass: nw - 12 apvllcatdectamvtametsollaeNatianalprePnstaulion AAVA/L Ol*k887 88 Approvals: UL, FM, gIG, VdG, and LPCB; Association (e.g., NoVA 25), In addition to the IMPLIED. t801dffl WARMNI7ES OF See Fine Protection Submittal Shoot far exact standards of any authority having jurisdiction. J$RCNAITADIUIY AWE 6178068 P88 A Listing! Approval lntoema000. Tttemnstaltirmgcontroctonarprodaclnraoafacluren PAR7AflR Page 1 o12 July 2004 TFPI850 Page 2al2 TFPneso Figure 772 Grooved Coupling Not 0.1 - 71 • Maamerunn available gap belrsenrr pips ends. Minimum gap 0. Msalmvnr pressaro and end lead ore total ernnr or loads based on standard sslgbl sInai pipe. Prnseare rsnngs and end leads may differ an artier pipe materials eedlor welt thletvrrass. Conlaaebpea Fire Products for details. Sea Fire Pretenses Eqalyareoe 000rnitesr sheet ten Listing sod Approved pressure songs. Gate color coded motile boo sizes are available upon request Mae End Gap motor evil grooved standard weight pipe. Values for eat grooved pipe will be to that of eat grooved. Rove 772 Rigid Couplings hors soffrre-Rotarlae Feature of 'gripping taettr along Ore coupling keys in sizes l'/ - 4, wi/dr make the Figure 772 perfectly suited tar 'an ever irrstataeoes where he hkellhOOd at rotation is Greatest. Ti/a leatore may eliminate the need at extra hangers to support the arm ever due to Increased nlgiloty and gripping tame saving erie and nose. General Nutov: it is the Devignor'e responsibility to 001000 products saleable for the intended service and to ensure that pressure ne5ngo and porlOrmaOon data a net exceeded. Always reed and understand Ore installation 0, Instruerloen lIH-10061. Never nernrove any piping sornpenerd or eorroer or nnod6p any plpbrg delisendan wthosl nine depressurizing arid draining the system. Material and gasket selection should he veined lobe compatible for the synalvs application. Certified Compunp 17C0 FIRE PRODUCTS. 454 North Cannon Avenue, Lansdale, Pennsylvania 16546 Printed U.S.A. Pipe Mwa,5 Mes,t Mox.t Nominal Dimensions End Gap Pressure End Load Bolt wt. - 0.0. A B C Size loclres Inches psi Lbs. Inches loches mates Lbs. -- - mm mm Die L - . 1.660 0,06 - 300 -- 649 2,75 4.38 1.61 Wo2rh. 1.0 42.4 1.5 2,068 2,887 69.9 ff1.3 46.0 Mt0o57 0,5 1.600 0.08 500 1,417 3,00 4.82 1.61 hofa2r,r 1.0 48.3 2.0 3,447 6,303 76.2 117.3 46.0 Ml0n57 0.5 2.375 0.13 500 2,214 3.41 5.12 1.88 fofa2l/5 1.5 60.3 3.3 3,447 9,848 86.6 130.0 47.8 Ml0o57 0.7 2.675 0.13 500 3,244 3,91 5.83 1,88 3Of52r/r j 73.0 3.3 3,447 14,430 99.3 143.0 47.8 M10a57 1.1 76.l 3.000 0.13 300 2,120 4.19 5.72 2.00 M10057 28 78.l 3.3 2,068 9.430 106.4 145.3 50,8 1.2 3.500 0.13 500 4608 4,63 6.25 1.88 3Ofs2W 4 88.9 3.3 3,447 21,387 117.6 I58.8 47.8 M10n57 1.2 4.500 0.15 500 7,948 5,61 7,50 1.67 Wo2/. 3$ 114.3 4.8 3,447 35,353 147.6 190.5 500 Ml0mn57 1.6 l39,7, 5.500 0,19 300 7,n27 7.02 9,72 2.06 M16o93 139.7 4.8 2,068 31,701 178.3 246.9 52.3 3,4 5.563 0.19 300 7,268 7,09 9,71 2.04 Wo3Vo 7.5 141.3 4.8 2,068 32,417 180.1 246.6 51.8 MI6x83 3.4 165.1 6.500 0.t9 300 9,950 8,09 10.53 2,13 Mn6a83 165.1 4.8 2,068 44,258 205.5 267.5 54,1 3,4 an 6.625 0,19 400 13,782 6.09 10.53 2.13 Wo3'/ 7,6 168.3 4,8 2,758 61,302 205.5 267.5 54.1 Ml6u83 3.4 an 8.625 0.19 450 26,278 10.56 13,56 2.62 Wo4fOf 18.0 279.1 4.8 3,103 ff6,885 260.2 344.4 66.5 M20x121 8,2 10.750 0.13 250 22,879 12.64 16.41 2.62 ?o6W 24,6 273.0 3.3 1,724 100,876 326.1 416.8 06.5 M24o 165 11.2 12.750 0.13 250 31,803 15.41 ¶8,64 2.62 Vo6W 420 323.9 3.3 t,724 141,905 391.4 478.5 66.5 M24mm 165 19.1 - h- tqCo/ Fire & Building Products Technical Services: Tel: (800) 381-9312/ Fate: (800) 791-5500 www.tyce-tlre.com Grinnell Grooved Fire Protection Products Grooved Fittings General Materiel: Limited Cast: Figures: 201, 210.219,250,260.501,510, Description 519, 5IODE, 5015 5108 and 5198- Warranty See Fire PretenSion Ductile Iron conlonoing to ASOM 0-536, Products by Are Products am Submittal Sheet for Grade 65-45-12 warranted onisly to the original Buyer for ten (10) Pressure Rating and Fabricated Steel: Figures 391, 392, 393, 312, in1ret int aterial andeonivamstsp lJating/Apprnvet 313, 321. 327. 341 and 050- Carbon Stool, when paid forand property Insisted! and maintained (Shoe It- 12 ore Schedule 30), epirnlea(te)yeannhnmtbteotshlynrandbyTyan lnlentreltoer (Shea 1'/a - 6 ore Schedule 40): stolen rorneul use and sothee This asnuntywli conformingto ASTM A-53 Grade B AmProdectu. hewanatdyisgioentarprodectsor Tlregssnvedfitsngaprovideanecenomical Protective Coatings: components manufactured by companies not and ettictentmethodetchaegiegdlreotlon, • t&tn-ltad orange paint aff91atodbyawtershiawithTycoAroPtnductsor1nr adding an Outlet, reducing, or capping • Fire brigade rod (np5ana nan-lead paint pmandrempotswhichtoeeltwnsub,lect greased piping systems. Grooved fittings .601 dipped galvanized contomnlng tnAS1M wmlsuse,tenpmponlnstathtion,cormslon,trwtrich are available in durable ductile iron or A-153 hare not been hetaled, mnintairwd, nreduiod or fabricated steel as indicated. repaired inaocardancewith applicable Standards of Mote: Figaro 51119 and 519$ liftiags are Ordering the tiatnirxt Am Protection Association (NAPA). special short radius lifflege with smaller center In end dimensions than ,tasdard Procedure atidtsrwstordurrbofaryotherAuthnrillestravbrç Jurisdiction. lkietiatststodbylyrefitePrndids grooved fIlings. Depending an the sloe and When placing an order, indicate the full product tabedofnchueniellbeeitiiertepakadorinpisced,at coupling used, there may be Interferences al eams. Please specifytirequantity,tigursoumnittr, TycoRrePtoducts'teleoptiorr. TycoFrnProducta the tuellpads lttalrequire repositioning ntthe wall tinictoress, and uhn. rroUtrer asooerrea, nor auttenrizee any person Is coupling orientation. The use at hang. Grinnell Grooved Piping Products, valves, aosansattriLariotlwrsbligslloninonnimclionwith adapters Is not recommended with Figures accessories and ether products are available the ask ofptndta2serpattsotpnodtoso, TycoRre 5108 and 519$ lifting;. Content Tyco Fire ihrnughouttlml2S.,Canado and lntnmatiotralty. Ptabdueedheinrmpesottdelersprbdlersystom Products lee details. ihrnegtr a network at distribution centers. You danlgrnntorvorhasccurataorbranmpletubilenrelien WARRING may write directly or call 215-362-0700 for the supplied by Buyer or Bayer's representatives. The Fiflivgs described lre,nln must be Installed distributor neatest you. IN IS) EVENT SHALL TYCO ARE PRODUCTS BE andmainlulnedincompliovceerilhttdsdxvntent LIABLE, IN CONTRACT, TORT, STRICT LIABILITY as well as with the applicable standards of Care and OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR liaoona/ fire PrutectionAssoclatio,o ntsddutlon Maintenance to the standards of any other authorities having jurisdiction Foliate to do so may Impair She The owner is responsible for the inspection, LIMITED TO LABOR CHARGES, REGARDLESS OF performance of title 0ow169. testing, and maintenance at their fire protection WIIETHERIYCOAREP600UCISWASIIIPRRMCE) The owner In responsible for rrralnioining their system and devices in accordance with the ABOUT THE POSSIBILITY OF SUCH DAMAGES, fire protection system and devices in proper appiioahlestsndanrlsotthetrbtlarraiflrePmtochnn AND INNOEI/ENT SHALL Fr'COAREPRODUCTS! ope,ahngcondhiuru Tlreinsfalingcord,scloror Association (e.g.. NFPA 25), In addition to the IJAUIiJTY EXCEED AN AMOUNT EOUAL TO THE sprinldermanufaclumrshouidbeconiactodedtlr standards of any authority having Jurisdiction. SALES PRICE. any questions. lhnirntallrgconttnclnrorprnductmanafacturer should be contacted relative to any questions. MTL 0I W1W4V1BNG Technical Any impairment must be immediately corrected. IMPLIED. INCLLtDI98 VARRANI7ES OF Ills recommended that automatic sprinkler M11RBMRTAIICI1Y AND 9179811$ FOR A Data apptamabelnspernd,tmnd, and maintained by WWllLA8ft6. pprenate: a qualified Inspection Service. EL All. ULC, VdS, and LPCB: Netw See Am Protection Submittal Sheet for exact LisUn /Apprnual intnrmalion. Page 1 of 6 September 2004 TFPI8IO Page i aa 10 .6 14.6 [Branch Flum 165.1.m 3M 25.0 0.50 1. 23. 31.0 72.1 133.4 41 1 159.0- 165.1- 48 1 9. uets TFPI8I0 Figures 201, 210, 219, and 260 -in (Jf SIZZa Figure 201 1.1 Figaro 210 27 F ure 200 Figure 219 .Avatbl..e,Spe*9t451, Conner nine FIr•& SOOna healers FO,,s a we. .,ds,an. aeth.cS,rth.rbe,mwOwna 50. StCot, .5. Ermnu.: or Cent urn, be.re, v.5.0' lxv se. Fneuv ,e.ln.nv. In.aa.twaa,dt.floecwrnwm.nrtS sea urea. FlgUre2Ol Ftpsre2tn Agsrs2le Figure 26M 455 Elbow 90 Elbow Toe End Cap - Inch. Lbo. Inuiree Lbo. lnnttoe Lus. Inchee Lb.. mm *mm Ky. mm 445 04 99.9 0,5 _tt 69.9 0.6 22.4 11.2 I 1. 7YIC 445 0.5 DIC 009 0,5 '5IC 69.9 8.8 i1 224 ttr 0.3 - 2 50.9 W 0,0 '5IC 82.5 0.9 18tt 82.6 1,2 798 22.4 - 0.4 57.2 22 1.0 953 1.4 9.3 5 2,5 iIC 224 0,4 THmm 572 1,0 953 32 1.4 95,3 2,5 23.9 1.1 0.5 2.5 83.5 35 -si- 1.6 18 t08.0 2.0 i 108.0 3,2 i1 22.4 -w 0.5 rm 2AR 720 $ 2.5 1257 3.9 1207 5.2 - T8' 76.2 8 2.4 i 127.0 29 tt 127.0 ltr 5.4 .T 25.4 -ttg- t.2 ' 02,9 3.5 a 133,4 ir 5,1 tt 133.4 4.0 - - - t357mm321 826 7.r 3.5 181 t357 5.t 139.7 8.9 iT 214 2.1 92.6 3.9 iT 139,7 6.1 1N2 139.7 W 7.7 181 234 2,3 3 98.9 12.0 5.4 iT t52.4 0.6 100 152.4 1ST 6.3 - - - 839 12.5 5.4 iT 165.1 TICS 8.4 882 165.1 11.8 IT 254 w 3,4 6 IT 98.9 5.4 iT 165.1 11r 0.4 105.1 18T tt.9 IT 234 34 2083mm IT 0090 10.4 IT 1959 1ST 18.6 58 196,9 1ST 20.4 - - - -181 a 100.0 - 10.4 IT 1959 1ST ISO 7D 1959 1ST 28.4 IT 302 5.0 -:- IT 1207 14.1 IT 2256 1ST 27.2 126 228.6 32,7 IT 31.8 1ST 9.1 l2 - 1SF L 1082 AM.0 ,78 1082 1SF IT 31.8 1IC FdnSne Resietaooe (Expressed as Equivalent Straiçt Pipe) : o: Size oeFeet Feet FeetHeretoMete,u Merr,r 0.0 Metro' i i.r1T 0. t.5 0.7 0.6 0.4 t.8 0.7 IT 1.0 0.5 2.5 t.2 t.O 0.0 6.6 g 3.0 1.2 1.2z:inn.IT 0.5 3.1 t.2 - 00.9 - iT 1.5 0.7 3.7 IT 1.5 108.0,,.. -ICr 2,0 ST 1.0 187 5.0 IT 2.0 r 114.3 iT 2.0 7T 1.0 187 5.0 iT 2.0 - t33,Oe., T 2.4 i.2 0.1 TIC 2.4 - 139.7,,., ii- 2.4 -TT- 1.3 IICIC 0.1 iT 2.4 i IT 587 TIC 14t.3 2.5 1.3 0.3 2.5 - Tr 2.9 ICT 1,4 287 7,2 iT 2,9 - IT 2.9 1.4 587 7.2 TIC 2.9 09.3 iT 3.0 IT 1.5 587 7.6 3.0 21e.3,,.. 4.0 2.0 10.0 227187 4.0 219.1 is 4.0 2.0 s 10,0 4.0 2730 5.0 2.5 12.6 5.0 -itt- 871 IT 087 ysi 323.4 6.1 3.0 15.1 0.1 Page 3 of TFP1SIO Figures 501, 510,519 and 51 ODE C 70 5 (r j; E41 Figure 551 FIgure 010 FIgure 519 Figure SISDE Flgore6ol Flgare5i0 FIgsreSig Figore5l0DE - 45 'how 90 0770ow Tee 60 Drete Elbow nr flat size i Inches M C the. i inches . .59. i Inches .50. Inches Inches 2105 WL Inches.55. s. K. mm K. mm Ka. mm mm mm 1/. 445 0.4 69.9 8.5 2J5 68.9 0.6 - - - 44.5 -- 0.5 69.9 0.5 69.9 0. - - 2 50.8 0,8 '539 82.6 0.9 82.6 --r -r--- 1.2 - - 2 57.2 7.0 3.75 95.3 _6_ 1.4 95.3 2.8 .is 95.3 00 50.8 69. 69.9'99 - 2 63.5 1.6 4 108.0 2.6 708,0 -,- 3.2 r 105.0 50.4 2.75 69. - 76.2 -- 2.4 5.00 727.0 3.9 00 727.0 5.4 727.0 72.4 5 7.0 69. - 3 82.6 3,9 5.50 739.7 - 6.1 739.7 7.7 r 139.7 - 55.9 '. 69.9 5.4 s 165.7 8.4 765.7 .o 71.5 8 765.7 3.52 99.6 Z 69.9. 6.? 708.0 70.4 796.9 35.5 16.6 7.75 798.9 96.0 20.4 715 796.9 423 725.7 syr 69.9 r 11.9 Figures 501$, 510$ and 519$ -Coo cL Figure 501S Figaro 510S Figure 519S Friclion Recelncce 5015.5150 & 515S (Expressed as EooIouJe,,0 Slr0i9t Pipe) as SIze ar r ssr oor Inches mm MoOn 1611.13 Melon 16810,3 m -tr s.o T 60.3 7.0 0.5 2.5 7.0 73.0 - 7.2 2.0 0.6 r 3.0 7.2 T T 1.2 5.6 3.7 1.2 -s- 88.9 1.5 0.7 122 3.7 4.1 7.5 r - 774.3 2.0 7,0 5.0 2.0 139.7_- , - 20.0 2.4 7,3 67 2.4 -5- 14 .3 , 2.5 - 1,3 20.3 8.3 5Y 2,5 165.1- r r r -sr 2.9 1.4 7.2 2.9 w r 768.3 3.0 7.5 7.6 3.0 279.? 1T 4.0 W 2.6 70.0 4.0 I C, Page 4ot8 TFPI810 Figures 250 and 350 .-5t0E- Figure350 Fabricated Sizes 3" to 6" Figure 350 Fabricated Sizes 8" 7012" .65: oanna*.d,40w,atfls flene*ntel.apbonatoCat bcaslnauan.n.tat .,.,*n655 0, FQC sncv.aiaced. ADA CAP® Patented 0,I), 700.7 co-ats 04.rzerce,-aO eon - F r55250 and 350 ConcantriC Radacer - Oroovae Oracle - - Nominal E to E Appo. WI. Nominal E to E Appa. WI. Nominal SIc E App.. WI. Size Inches Lbs. Size Incilee Lbs. size Inches Lbs. tochen mm _•g Inches mm ••• Inches mm *2 e I/o 2.50 1.0 • 3.50 4.2 4.00 5,6 035 05 959 ,g *6 605 707.8 2.6 1.3 "26 Id 635 06 139,7.o.o ' 88,9 20 602 727.0 55 "21A Figure 250 2.50 1.2 3.50 4.8 S.00 12.1 02 935 Sold 889 2.7 7270 5.5 2501 2.50 1.5 3.50 4.6 6.00 12.0 76.l,,e 63.0 0.7 502 88.0 2.1 803 127.0 5.5 - 76,1..02 - -i'- -fl- 3 -- , 6.35 08 5024 889 20 127.0 5.4 -- 301/, - -ti- 3 -- - 935 06 5e3 88.9 2.0 805 127.0 5.1 2.50 7.3 3.50 4.5 5.00 10.8 30 Id 63.5 0.6 *5 504 68.9 2.0 506 127.0 4.9 • 2.00 1.3 • 4.00 5.5 0.00 21.9 302 63.5 0.8 185.7.,.,. 03 707.6 2.5 1504 752.4 70.0 _ 6.00 2 "2e2'A _________ 965.I.a4 1005 "2078.1.,... 3j0 lacr....01967 752.4 66 3.00 2.2 • 4.00 6.0 8.00 79.5 401/. 762 7.0 802 707.8 2.7 lOse 162.4 69 3.00 2.3 4.50 6.0 7.00 '" 40 Id 76.2 70 6024 101.6 2.7 7204 777.8 72.7 402 3.00 2.3 • 8s78.l.... 4.00 0.0 12c0 7.00 30.0 762 I. 701.6 2.7 177.8 13.6 402.4 3.00 2.3 4.00 6.0 7.00 20.0 _ 702 7.0 803 707.6 2.7 12s9 177.8 72.7 *4 76.1,..,. e 3.00 3.2 • 604 4.00 5.9 125 IS 7.00 33.0 762 75 101.6 2.7 177.8 15.0 3.00 2.8 4.00 0.3 - 403 76.2 -1.2 60 130.7.. 707.6 2.9 Fl 0 Nominal Dimensions Net - Takeout Qtinlgr 1, End Inches Inche lncheo inches Lbs. Inches ,,,,, mm mile JSSL. Kg, - 1.25 LL 1.75 L 1.89 L 5.77 QL 1.25 1.75 1.89 0.77 1.900 453 31.8 44.5 4.2_ 0.3 7,37 2.00 2.02 0.88 LL L iL - 1.25 ILL 1.75 L 1.89 0.82 0.4 - .±... 7.25 378 1.75 .4 1.09 i 2.375 663 1 1.37 2.05 2.02 1,06 34.8 50.8 57.3 0.5 1.47 ILL 1.07 ILL 1.89 4B.0 1.28 L ~1, 7.47 1.97 7.89 1.28 2.875 73.0 37.3 50.0 48.0 0.6 7.37 2.00 2.02 1.50 - ILLILL ILLL Page5of6 1FP1810 Figures 391,392, 3939 312 and 313 _ 0100 393 Figure 391 Sim 60 Figure - 392 p 4 Figure - 393 4' 10, 8.00 . Figure 312 -L 313 Figures 327 and 341 Figure 327 re 341 Adapter C to E sops. WI.sopS. Wt. ml ricSim hes Lbs. MM ka. Inches Lbs. MM rEfEli Cress - - - 75 1'I. r44. COE 2.75 2.2 I / 3.2 69.9 2.9 1.5 2 Figure 327 - -t24 95.3 2.3 3,6 4.25 7.1 10.2 tOSS 3.2 101.6 4.6 5.00 11.9 1270 I . IT .............. _.ii.... 6.00 17.2 ..i!. .._ Z5. 5.50 17.1 6.00 21.4 0100 7.8 9.7 I I 6.80 27.5 6.00 26.0 1651 12.5 152.4 11.8 7.15 47.0 8 6.00 39.4 Fl 341 796.9 27.3 1524 17.4 9.00 99.0 10 228.6 30,8 8.00 65.0 203.2 29.5 12 19.00 t07.0 8.00 91.5 254.0 48.5 203.2 47.3 Page 6aI6 TFPIOIO Figure 321 C.E Figure 321 Genetic Notes:It re the Designers responsibility to select products suitable for the intended service and to ensure that pressure 161550 eocl parromlance data Is not exceeded. 6luays reed and understand the hrstu9ahou lnalnatb.rs 9001 (lH.l000. Never remove any piping component Or Correct arm any 81pin9 dellcleeoies Without first depressurizing and drainingthe 6601cm. Material and gasket selection should be ve,1604 lobe compatible for the specitic application. Certified Company TYCO FIRE PRODUCTS. 451 North Cannon Avenue, Lansdale, Pennsylvania 19940 Printed U.S.A. FigUres 391 Figure 312 FIgaro 313 - Adapts NIDoles 0 22V? Elbow IE mnrinat Inches Lbs. Inches Etc 6 eppo. WI. C Ia 6 A9p6. WI. C tab Lbs. Inches bs. I. o. mm Kg. mm KS. mm Kg. - 4.00 0.8 1.1$ 0.4 1.38 0.4 701.6 0.4 44.5 0.2 35.1 0.2 11.1 4.06 0.9 1.7$ 0.5 1.38 0.5 I/s 101.6 0.4 44.6 0.2 35.1 0.2 4.0 1.2 0 188 0.8 1 0.6 101.6 9.5 47.8 0.3 35.1 0.3 4.013 1.9 2.02 0.7 1.50 24 101.6 0.9 50.8 0.3 38.7 0,5 00 2.8 225 1 1.99 1.2 19t.6 1.1 57.2 0.6 38.1 8.5 8.00 5.5 2.63 2.4 1.75 2.2 152.4 2.5 66.9 7.7 44.5 1.0 6.02 7.4 2.90 4.1 2.90 3.3 752.4 3.4 732 7.9 50.8 7.5 8.00 9.5 3.13 5.8 2.00 4.6 6 152.4 4.3 79,5 2.5 50.8 2.1 14.2 3.88 III 2.00 9.7 8 752.4 6.4 98.6 5,0 50.8 3.9 - 27.0 4.38 14.0 2,13 9.1 203.2 12.2 11.3 54 54.1 4.1 33.0 4.88 22.0 2.25 16.7 12 203.2 75.9 724.0 10.0 57.2 7.8 - - cr576 Tee - hornirel Sloe todses 86p0.WL Lbs Figure 321 Wt Idemblal Sloe CbS Inches ZZ Lbs. Inches mm Inches nor Ir,5n11401~ 3.25 2.0 6a604 8.50 28.8 fl - ----------- $ 9. 7.75 7-73 393, 82.8 0.9 _________ 165.1 12.7 2622 1r4 325 2.7 696 as 6.50 iT 82.6 1.2 76Sf 12.2 2%525s01'/s 1W 4.2 8a892 36.2 95.3 1.9 1959 76.4 2½s2½0114 i: 4.2 93.3 7.9 192.9 76.0 21402½s2 '12 3-75 7.76 36A 8a804 95.3 2.9 198.9 76.8 3o3c 114 Z 5.3 80609 7.75 36.8 108.0 2.4 198.9 76.7 30302 4.25 5,0 80806 7-75 37.0 708.0 2.5 796.9 76.8 30302'A '' lselos2 9-00 108.0 228.6 25.9 4040114 520 9.2 I5oIOs3 • T 727.0 4.4 228.6 289 4o4s114 5.05 1051064 900 57.8 727.0 9.9 57.8 4.5 2288 26.1 40402 , -mr loelOso 920 727.0 4.6 228.6 26.2 4s4s2½ 520 103 1061066 9.00 i:o- __________ 127.9 4.7 2286 26.3 40403 16010s8 6.00 58. 727.0 4.8 228.8 26.5 5e502 I2x12s3 10.00 80.2 ' 739.7 6.6 254.0 36,4 5556210 6.50 lOS 1201254 Th6 'T 739.7 6.7 2560 36.5 505e3 6.50 '.2 1501255 1 r- 139.7 59 __________ 294.0 36.6 00504 12n1256 10.00 BOB 36.7 65652 6.00 28,5 1221258 'i ___ 254.0 47.5 5u6 6214 6.00 12012610 Th• -i 254.0 41.8 60603 6.59 26.5 Fig..200 - "Trimline" Adjustable Band Hanger Size Range - 1/2" thru 8" pipe Material - Carbon Steel, MU. Galvanized to G90 specifications Function - For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features - (1/2" thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. (2/2' thru 8" Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals - Underwriters' Laboratories listed (1/2" thru 8") in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW-H-171E, Type 10 and Manufacturers Standardization Society SP-69, Type 10, Maximum Temperature - 650°F Finish - Mil. Galvanized. For Stainless Steel materi- als, order TOLCO Fig. 200WON, Order By - Figure number and pipe size (1' , I I ,, •,j,,. h '5 li,' ./ 112 IHRU 2 INCH PP8 Dimensions 'Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. Length 1/2 3/8 8mm or 10mm T/8 2/a 400 11 3/4 3/8 8mm or 10mm 31/8 21/2 400 11 1 3/8 8mm or 10mm 3Ia 2% 400 12 1114 3/8 8mm or 10mm 33/4 21/a 400 13 11/2 3/8 8mm or 10mm 37/s 21/a 400 14 2 3/8 8mm or 10mm 41/2 3 400 15 2'I2 3/8 10mm 5°/s 41/ 600 27 3 3/8 10mm 57/6 4 600 29 31 3/8 10mm 7 /8 5'/4 600 34 4 3/8 10mm P/9 5 1000 35 5 1/2 12mm 91/8 61/4 1250 66 6 1/2 12mm 10/8 61, 1250 73 8 1/2 12mm 131/ 8/4 1250 136 Main Office/Manufacturing Facility. 1375 Sampson Avo. • Corona CA 922/0 • Ph 909.777 6599 • Fax: 737,0330 Customer Service' 000 720 5266 wwwtolco.gcm 3/8" thru 7/8" rod in 1" incrTnnts Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter, rod length and finish Dimensions 'Weights Rod Max. Rec. Load Lbs. Size For Service Temps 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 - t.. Fig. 98 - Rod Stiffener Size Range - Secures 3/8" thru 7/8' hanger rod Material - Carbon Steel Function Secures channel to hanger rod for vertical seismic' bracing Finish - Electro Galvanized Note - Available in HDG finish or Stainless Steel materials. Order By Figure number Fig. 99 - All Thread Rod Cut to Length Fig. 100 - All Thread Rod Full Lengths Size Range - Secures 3/8" thru 7/8" rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Dimensions 'Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F 750°F wt./100 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 1/4 8000 7140 360 11/2 11630 10370 510 Maui OfficeIManuacturing Facility . 131 Sarlpven Ave. Cemne. CA 927 Ph O9.l3i C&9 1n O737.O33O Customer Service •8'Y0,786:)266 wwtociscum P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 162 REVERSIBLE UNIVERSAL BEAM CLAMP 3/4" MOUTH RESTRAINING STRAP Nut optional, if insufficient rod dimension ie SIZE - 3/8" and 112" rod. MATERIAL - Ductile iron. FINISH - Plain, E.G. and H.D.G. LISTINGS - c'ZlYas 203-EX 2551 <S> Approval guide- Pipe Hangers FUNCTION - Hanger assembly attachment to steel flange with thiôkneas of less than 3/4". INSTALLATION - Per NFPA 13 with set screw up or down. Torque - 318"= 60 inch lbs. or 1/2" 125 inch lbs. In the absence of a torque wrench, engage set bolt finger tight then additionally tighten 1/3 turn. FEATURES 5Listings allow installation with set screw up or down - see drawings. 5 Maintains CONSTANT BANGER CENTER-LINE, with set screw up or down. Plat throat back to prevent twisting on flange during installation. ORDERING -Part #, rod size and finish. SIZE- One size fits both 3/8" and 1/2' rod or set screw. Available lengths 4" and longer. MATERIAL - Casbon Steel. FINISH - Mu. Galvanized. LISTINGS - c?w 203-EX 2551 PATENT - No. 5,897,088 FUNCTION - To enhance banger attachment in areas subject to Earthquakes. INSTALLATION - Install tight to struc d component parts Minimum return on=I" L-dimension is measured from hanger rod center to the strap end. FEATURES Fast installation for new construction or retrofit Requires no banger disassembly to install. IMPORTANT NOTE: 'No Not Is Required" When installed tight to structure and component parts. (See drawings provided) ORDERING - Part # and L-dimension. 1/08 1/08 / P.O. Box 3365 South El Monte, CA 91733. 626.444.0541 Fax 626.444.3887 www. Afcon.org jiI SWAY BRACE FITTING m Part # 077--- SIZE - SYSTEM PIPE: Nominal Pipe Size Sch. 40 Steel 1" - 12" Sch. 10 Steel 11/4" - 12" Sch. 7 Steel 2-6" MATERIAL - Carbon Steel or S.S. (Type 304) FINISH - Plain or E.G. PATENT - No. 7,140,579 LISTING/APPROVAL C®un 203A-EX 2625 FM Approved - 1950 usm FUNCTION - Longitudinal fitting of an AFCON sway brace assembly. INSTALLATION - Per these instructions including NFPA 13 or FM 2-8 Load rating - see chart. ASSEMBLY - See drawing. Combine with proper AFCON components- see disclaimer below. A 1.... L........ s.. 4'.,..,.. ...CA 11 ,...11 '" Max. Horizontal Load 1"- 4" 1200 5" -10 i 2765 12" 1 3740 '$> Max. ASO Horizontal Load System NPS Sch. 30"-44" 45"-59" 60"-74" 75"-90" 1-1 112" 10-40 1070 420 510 570 2" LW-40 1570 1900 1730 1930 2112'-4" LW— 1000 860 1030 1150 4" -5" 10-40 1000 950 1150 1280 6" LW -40 1620 2220 2720 3040 8" 10-40 1 2070 1250 1510 1690 ttttt1 It55I1UV1 454t1t LO Ii1'..' Ut 't&I tctoLcticl Itatuco. Tighten 1/2" bolts until fastener flanges connect. FEATURES * Patented - design eliminates bending of fastener flanges during installation. * Patented - design prevents over tightening on system pipe. * Improved assembly - fastener flanges connect for superior strength. * Visual inspection - proper installation when 411 fastener flanges contact. ORDERING - Part #, size - system pipe and finish. Specifle AFCONproulucts are exclusively designed to be compatible ONLY with other A FCON products including pails and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. IMSCLArMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems / not manufactured or sold by AFCON AFCON shall NOT be liable under airy circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to toss of business or profit, when non-A FCON products have been, or are used. / 2/16 4Zc 7z7 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 076 ATTACHMENT FITTING UNIVERSAL LOCKING 17/32 STEEL BASE SIZE - BRACE PIPE: 1" thru 2' Sch. 40 MATERIAL - Ductile Iron and Carbon Steel. FINISH - Plain or E.G. LISTING/APPROVAL - 203A-EX 2625 OSHPD See Website. FUNCTION - Structure attachment fitting of an AFCON sway brace assembly. INSTALLATION - Per these instructions including NFPA 13. Load rating - see chart. Combine with proper AFCON components- see disclaimer below. ASSEMBLY Insert brace element into fitting snug against back of jaw. Install set bolt finger tight, then additionally tighten 11/2 turns or torque to 40 lb-ft. Only tighten set bolt with hand tools. NEVER INSTALL SET BOLT WITH IMPACT/DRILL DRIVER. FEATURES * Swivel allows attachment at any angle. * Larger fastener hole available.- Consult factory. ORDERING - Part #, size - brace pipe, material and finish. C®ttn Max. Horizontal Load Lam [ 30° thru 90° I 2765 ---"4 Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON' products including parts and fasteners, resulting in a listed sway hence, restrainer or hunger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be table under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-AFCON products have been, or are used. P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 035 SWAY BRACE FITTING MODEL K U I 1 thru 4 Inch pipe 3 112 & 5 thru 12 inch pipe SIZE — SYSTEM PIPE: Nominal Pipe Size Steel 1' thru 12" * Steel Specially listed - see chart. CPVC 1" thru 3". Brace common O.D. - Copper, Plastic, FRP SIZE — BRACE PIPE: 1" thru 2" Sch. 40 Mm. 11/4" required for 12" system pipe MATERIAL — Carbon steel and ductile iron. FINISH — Plain or E.G. PATENTS - No. 7,516,922 No. 7,523,895 LISTING/APPROVAL — ceus 203A EX 2625 cotta FM Approved - 1950 OSHPD See Website. FUNCTION — Lateral fitting of an AFCON sway brace assembly. INSTALLATION — Per these instructions including NFPA 13 or FM 2-8 and CPVC manufacturers instructions. Load ratings — see charts. ASSEMBLY — See drawing. Combine with proper AFCON components- see disclaimer below. Insert brace pipe through bores to achieve minimum 1" extension. Tighten 035 set screws until heads bottom out. FEATURES * Patented — designed for system pipe of varying material. * Improved assembly — extra large bore for brace pipe. * Visual inspection, verifies proper installation. ORDERING — Part #, size — system pipe, size — brace pipe and finish. ' Max. Horizontal Load sstem stZts 3cr-44' 45'-59' 60'-89' 90' 1' 1 (140 1 12 1 i& 2394 27 I 1/4' 2' 1383 1 1956 2.4 27 21/7'-4' .14Q. .138. i. .24 27 .133. i9. .24 2Zfi5 8' 10-40 1383 1956 2394 2765 10' 10-40 1383 1956 2394 12' 10-40 1870 2645 3238 Max. ASD Horizontal Load System — Sch. 30'-44 45'-59' 60'-74' 75'-90° 1'- 11/2' 7-40 1680 2380 2920 3250 2'- 3' 7-40 1800 2350 3120 3490 4" 7-40 1370 1930 2370 2640 5', 6", 8' 7-40 730 1040 1270 J9 Special Note: Thin wall sprinkler pipe has a propensity for damage to its circumference resulting in egging. When egging exists - shift mounting location. Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER- AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shalt NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-4FCON products have been, or are used. 8/16 Structural Brace Attachment (cont.) Horizontal Steel Flange Seismic Load Parallel to Flange BI Vertical Steel Flange Seismic Load Parallel to Flange .47F00n. SEISMIC BRACES oAww Fig. AF087 (Formerly Afton Fig. 087) Structural Brace Attachment Size Range: Flange Thickness: Up to '/2" thick (UL). Up to /o thick (FM) Material: Ductile iron with Carbon Steel Hardware Finlsh El Plain or El Electro-Galvanized per ASTM 8633 Service: A seismic structural attachment designed to attach to steel I-beams, flanges, and joists. The Structural Brace Attachment rigidly braces piping systems subjected to horizontal seismic loads. Approvals: cULus Listed (UL 203a) and FM Approved (FM 1950-10 & FM 195013). Complies with the hanging and bracing requirements listed in NFPA 13. Features: Shear off bolt provides a visual indication that the desired torque value has been achieved. Installation Instructions Place structural brace attachment on a horizontal or vertical steel flange. minn APPROVED Torque shear off bolts evenly and equally until the head shears off. Install the/r mounting bolt through the Ys AFO7S, AF076, or AF077 mounting hole. The mounting bolt shall be installed wrench tight (typically finger tight plus'/, to r, turns). Installation angle determined by the brace angle of the brace pipe and the AF075. AF076, or AF077. Fire Protection applications shall also be installed per the requirements of NFPA 13 and local codes. Patent No. 6,629,678 Ordering: Specify figure number, finish and description. FIG. AF087: DIMENSIONS (IN) • WEIGHT (LOS) Mounting Bolt L W H A B Weight ,4 41/, 2 251 U. 4 2.00 a:tiplge.aplail:lnytutitg uIuuau1ygl.1I.ngI' Project: DAppreved Address: []Approved RD Soled Contractor. jJ Net approved Engineer. Remaitz: Submittal Data: Notes 1: Notes 2: 4QFCOfl. SEISMIC BRACES Fig. AF087 (Formerly Afton Fig. 087) Fig. Fig. Horizontal Steel Flange Seismic Load Perpendicular to Flange Fig. AF087 AF087 )76 Vertical Steel Flange Seismic Load Perpendicular to Flange FIG. AF087 cULus MAX SEISMIC HORIZONTAL LOADS: DIMENSIONS (IN) • LOADS (LOS) Structure Seismic Load Orientation Max Flange Thickness Max seismic Brace Le~admax P Size Horizontal Steel Flange and Vertical Steel Range Parallel to Flange rIo 1400 4 Perpendhubrto Range FIG. AFOO7 FM MAX SEISMIC HORIZONTAL ASD LOADS**. DIMENSIONS (IN). LOADS (LOS) . ANGLES (DEG) Structure Seismic Lead Orientation Min Flange I ThIckness Mao Seismic Brace Load at Bruce Pipe Angle' 30-44 I I 60-74 T 75-80 Parallel /s toFlaoga I 1270 1740 I I I 2148 I 2380 Vertical Steel Range Perpendicular to Flange I ( 1150 I 1830 I 3230 I ( 3610 Brace Pipe Angles are determined from vertical. The aRswaldt FM approved capacity of bone satjassnmbller em tried In Allowable Stress design 14251. For load Resistance Factor settee (L0) capectiss, the eltryn telaeo will need to be msitfiuled by 1.5. [ot5l Notaw Anvil lnternatievalbrand bracing components are designed robe compatible ONLY with ether Anvil International' brand bracing components, resulting lea Listed seismic bracing assembly. updated UL listing information may be viewed at www.ol.com and updated FM approval information may be viewed at www.approvalguide.com. Dlssf.Irnrer. Anvil International (Anvil") done not provide any warranties and specifically disclaims any liability whatsoever with respect to donli bracing products and components that are used in cerrrbioatroe with prothrcts, parts or cyaterrre not rrrars.rractured or sold by Anvil. In we event shall Atoll be liable for any Incidental, direct, conset1nential, sped al or indirect damages or lest profits where non-Anvil bracing corrporents hew hector am used. safaReaon'S.lsnrio R. Peot.dlefl D.sfg,. That may he amassed at www.nigbne.eesn APPROVED -Th P/N WOOD UI. ft 1iI_1!r fl::lIE:: —kn ~9'1 8007957 GST 10 X CPVC 1-1/2 300 1.5 8020957 SWG 10 X CPVC 1-1/2 300 1.5 8008957 GST20 X 2-1/2 850 1.5 X 4 1475 1.5 8068925 GST20SS X 2-1/2 850 1.5 8010957 GST30 X 4 1500 1.5 X 4 1475 1.5 -8009925 GST25-380 X 4 1500 1.5 X 4 1475 1.5 8022925 SWG 25-380 X 3-1/2 - 4 1500 1.5 X 4 1475 1.5 -8021957 SWG 20 X 2-1/2 3** 1250 1.5 8073925 SWG 2OSS X 2-1/2 1250 1.5 8139957 SHGST20 X 3 1050 1.5 X 4 1475 1.5 8141957 SHGST30 X 4 1500 1.5 X 4 1475 1.5 8140957 SHGST20SS X 3 1050 1.5 8142957 SHGST30SS X 4 1500 1.5 UL Max Pipe UL Minimunri . BX PiN EL UL STE St Size, in. Loj, M Thickness, in. 8038957 DSTR1 X 4 1500 0.035 X 4 1475 0.1050 8037957 DSTR 1-1/2 X 4 1500 0.035 X 4 1475 0.1050 8039957 DSTR 516 X 4 1500 0.037 X 4 1475 0.1050 8045957 DST 516 X 4 1500 0.188 X 4 1475 0.1875 8046957 TEK50 X 4 1500 0.250 X 4 1475 0.1875 8055957 SWDR 1 X 4 1500 0.037 X 4 1475 0.0600 8056957 SWDR 516 X 4 1500 0.037 X 4 1475 0.0600 8054957 SWDR 1-1/2 X 4 1500 0.037 X 4 1475 0.0600 8137957 SH DSTR 1 X 4 1500 0.035 X 4 1475 0.1050 8150922 XP 20 X 2 750 0.027 X 4 1475 0.1050 8153922 XP 35 X 3-1/2 1250 0.043 X 4 1475 0.1050 __________ CONCRETE; ______________________ FII 8059957 CST 20 X 4 8061957 SWC2O X 4 * SWG 25-380 Maximum pipe size in composite wood joist allowed by UL is 3-1/2" SWG 25-380 Maximum pipe size in wood timber or joist allowed by UL is 4" ** SWG 20 Maximum pipe size in composite wood joist allowed by UL is 2-1/2" - ** SWG 20 Maximum pipe size in wood timber or joist allowed by UL is 3" UL and FM tests were performed in compliance with NFPA-13 Standards. Fastening requirement: 5 times weight of water filled schedule 40 pipe plus 250 pounds 141 5UUU I-'i 1475 3000 PSI fdl"r~ :TEwBuiIdex www.itwbuildex.com 800-284-5339 SSS26 —— U.S. Pat. No. 3921989 Canadian Pat. No. 1009880 Other Patents Pending Potter Electric, Rd., 1990 GENERAL INFORMATION The Model VSR'F is a vane type waterfiow switch for use on wet sprinkler systems. It Is UL Listed and FM Approved for use on stool pipe; schedules 10 through 40, sizes 2" thru 8' (50mm thru 200mm). LPC approved sizes are 2' thrs 9. (50mm thru 2001TUm). The unit may also be used as a sectional walerttuw detector on large systems. The unit contains two single pole, double throw, snap action switches and an adjustable, instantly recycling pneumatic ro- lard. The switches are actuated when a 110w of 10 gallons per minute (38 LPM) or more occurs downstream of the device. The flow condition must exist for a period of time necessary to overcome the selected retard period. ENCLOSURE: The unit in enclosed In a general purpose, die- cast housing. The cover Is held In place with two temper resis- tant screws which require a special key for removal. A IteM !In- stallable cover tamper switch is available as an option which may be used to Indicate unauthorized removal of the cover. See bulletin no. 5400775 for Installation Instructions of this switch. UL,ULC.ndCSFMlJltad,FMIOdLPCBAPPrOVed,NVMEA Accepted, CE Marked Service Pressure: Up 10450081 (31 BAR) Minimum Flow Rate forAlann: t0 GPM (3BLPM) Mmalnnon Surge: 18 FOB (6,5 loris) ContacuRatlnge: Two sets of SPOT (Form C) 16.0 Anrpsat 125/250VAC 2.0 Amps ot30VDC Resistive Condatl Entroncee: Two knockouts provided for 1/2" condait EnvtronmentelgpaC9lcltlnfl$: Suitable for Indoor or outdoor use with factory 1n51a90d gasket and die-cast housing. NEMA4IlP54 Rated Enclosure - ase with appropriate conduit fitting. Temperature Range; 400/120'F, 4,5C/49C Nan-corrosive sleeve factory Instated In saddle. Caution: This device Is not intended for applications in explosive environments. slzeeAvallable: Steel Pipe schedules lOttrru4o,sizes 2'thru 6 901387 pipe 50rnrnthr5 200mm Note: For copper or plastic pipe one Model VSR.CF. Service Use: Automatic Sprinkler P'IFPA-13 One urtwo family gavelling NFPA-130 Residential occupancy upto four stories NFPA-13R National Fire Alum, Code NFPA-72 Optional: CoverTemperSwtich Kit, Stock No. 0090018 INSTALLATION: See Fig.2 Those devices nay be mounted on horizontal or vertical pipe. On horizontal pipe they should be Installed on the top side of the pipe whew they will be accessible. The units should not be In- stalled within 6' (I Sam) of tilting which changes the direction of the waterffow or within 04' (60 cm) of valve or drain. Drain the system and dr18 a hale in the pipe acing a circular saw In a stow spend drill. The 2' (50mm) and 2 112' (85mm) devices require a hole with a diameter of 11/4' 10 1/8' - 1/18' (33mm *2mm). AU other sines require a hole with a diameter 0/2' *1/8' (60mm *2mm). Clean the Inside pipe of all growth or other material for a dis- tance equal Is the pipe diameter on either side of the hole. Roll the vane so that it may be inserted into the hole; do not heed or crease it. Insert the vane so that the arrow on the saddle points in the direction of the waterfiow. Install the saddle strap and lighten nuts alternately to an eventual 50 fl-lbs. (68 n-re) of torque (see Fig. 2). The vane must not rub the inside of the pipe or bind In any way. Specifications subject to change without notice. Panel Electric Sl0nei Company •2cel Craig Road, St Lode, MO, e3146-4101 • Phone: 800,325-3030/Ceneda 000-882.1033 vcteor.pniteraignal.nonl POiNOSO IN USA MCI wuuccor - OEVW PAGE roF2 MFG.05400751 .7102 (1 ( VSR, @ F VANE TYPE WATERFLOW PoTrER -The Symbol of Protection ALARM SWITCH WITH RETARD VSR-F VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD FIG.1 FIO.2 SWITCH TERMINAL CONNECTIONS oorosc rasrm nencv - DO T UIAW nv nor Ton CLAMPING PLATE TERMINAL rena (covEn olFACTION) a noviOl errs roe ocsmo van oc,uv. USE TIlE 22OOOU OF mm Ec E. FALSE 51.4050. 0 V SETIVIC 5 U5UotIS ALTE-W TO ceruuL 501,-os iso C 0555E ME".FAR 1)05. FACTORY 5 SET TO V. C) IS TO IC1ALL 0051. 001.5 PIlE SIZE As NOSITOn ISLE SIZE C u0uRT (M Pff So ISO" I. SO"i (33,1,11 421,,,) pours a retries CAUTION: t Ic a' z' aria' . Or w.vionrrrrn An uninsulated section of a leo..,, Ia onnv,,1) or,.,., 02vI') single conductor should not ens PHOOIE 0 -FINER —MV be looped around the temil- cover Temper 1 net and serve as two sepa- in'tor rover In piano) rate connections. The wire 1 o j mast be severed, thereby 0101701105 OF vorrerene providing supervision of the o a 24 . APPROX. Trios sErvos (C SEcS.i connection in the event that A...iT rlm)wA) , . A r C the wire becomes dislodged r lO- 20-40 000 SI-TO -00 from under the terminal. nec. 1791-M FIG.3 - TYPICAL ELECTRICAL CONNECTIONS NOTES: FIG. 4 1. Tile Model VSR-F has two To remove knockouts: Place .ssllnhos, en. can be used to screwdriver at edge of knock- JL operate a central station, yb- probity or remote .(analno Unit, while the other conlact 1. su ut-dtooperad—local dbl. oats, not In the cooler. visual annunciator. Z at .A:-w A.ncb.nfLPCAPPMWf j at Cal antry must be —Isal to 3. For supervised nircallu son 00 nwiIuh Ternhioel C000eo- tion? drawing and na005n 2401_A note (Ro. 1). APPUCATIOMWARNINOI -- Due to the possibility of unintended discharges caused by pressure surges, trapped air, or short retard timen, watorllow switches that are monitoring wet pipe sprinkler systems should not be used as the sole initialing device IA discharge AFFF, deluge, or chemical suppression systems. TESTING The frequency of Inspection and testing for the model VSR-P and Os associated protective monitoring system should be In accordance with applicable NFPA Codes and Standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). If provided, the Inspector's lest valve, that Is usually located at the end of the most remote branch fine, should always be used for lest purposes. If there em no provisions for testing the operation of the flow detection device on the system, application of the VSR-F is not recommended or advisable. A minimum flow of 10 gym (38 Lpm) Is required to act/vale this device. IMPORTANT NOTICE: Please advise the person responsible for looting of the fire protection system that this system most be tooled in accordance with the testing instructions. PalsieD IN 05/0 MET. eeemmr - REV PAGE 2 OF 2 MFG. #5400781 '7702 BELLS ®POTTER The Symbol of Protection ULLleted Sizes Available: 6' (150mm), & (200mm) and 10" (250mm) Voltages Available: 24VAC 12OVAC 12VDC(10.2to 15.6) Polarized 24VDC (20.4 to 31.2) Polarized Service Use: FireAlarm General Signaling BurglarAlami Environment: Indoor oroutdoor use (See Note 1) -40 to 150F (40 to 66°C) (Outdoor use requires weatherproof backbox.) Termination: 4 No. 18 AWO stranded wires 6" BELL SHOWN Finish: Red powder coating Optional: Model BBK-1 weatherproof backbox These vibrating type bells are designed for use as fire, burglar or general signaling devices. They have tow power con- sumption and high decibel ratings. The unit mounts on a standard 4° (101 mm) square electrical box for Indoor use or on a model BBK-1 weatherproof backbox for outdoor applications. Weatherproof backbox model BBK-1, Stock No. 1500001. ALL DC BELLS ARE POLARIZED AND HAVE BUILT-IN TRANSIENT PROTECTION: Potter Einntrlu Signal Company • 2081 Craig Road, St. Louis, MO,83146.4161 Phone:805.325-3936lCefludu 888.882.1833•WVOL.po0eTNIgflOi.COTTT PRINTED IN USA Mitt. n005000l. REV S PAGE I 0F2 MFG. 05400T76-5105 Notes: Minimum dB ratings are calculated from integrated sound pressure measurements made at Underwriters Laboratories as specified in UL Standard 464. UL temperature range is -30° to 150F (-34° to 66°C). Typical dB ratings are calculated from measurements made with a conventional sound level meter and are Indicative of output levels in an actual installation. — 'A S' . - — --A... '•. .--•- 'LI. - 'S p- .--.- - --. .., •--- . . -.I- '-- .--. - __r_.___ .. .--- . t1 I•' - :.. TI --. - -----. --- .. __,. -- __•_ _i1_____. -• -- - .- .8 -- '5',' .-- -- - @PoTrER BELLS PBA-AC & PBD-DC The Symbol of Pmtecilon DIMENSIONS INCHES (mm) FIG. I BELLS FIG. 2 WEATHERPROOFBACKBOX 5OXHASONE1HREADEDII2CONOUrrENTRANCE J01 1. e- L 3/8 (200) q3INe 201 2 11/1 (ire) (eel 025. 8778-2 FIG. 3 WIRING (REAR VIEW) D.C. BELLS (OBSERVE POLARITY) A.C. BELLS rae 25 i(a 100 0070 (LiT) cI~(::_ non 25 .) 80005) .on lao) raumm LID QASImOON SSa S 00I a S LOS SIT hAL IS SIALS no. mwwa sornuon S na On use aLT tEAL AS SALTL. rALUM TalEs 85000 1, os,znrn esteem To 055 SC. SIU.5, 1. ReiN INns 0.0. 8111.0. 70807.070 COOL EXTRA 855 oinanitLv 2. RED 81805 0057101 a) TCX 1.257 00.1.. 5. 51.001 WIno REGOTNE 1-) 2. OlO-OF.-UtLE REXISIOn 5 NOT erasers ON NC. SILLS 0006. #775-3 INSTALLATION The bell shall be installed In accordance with NFPA 72 or local AhJ. The top of the device shall be no less than 90 Aff and not less than 6" below the ceiling. Remove the gong. Connect wiring (see Fig. 3). Mount bell mechanism to backbox (bell mechanism must be mounted with the striker pointing down). Reinstall the gong (be sure that the gong positioning pin, In the mechanism housing, isin the hate to the gong). Test all bells for proper operation and observe that they can be heard where required (bells must be heard in all areas as designated by the authority having jurisdiction). PRINTED IN USA M. #0050007 . REV S PAGE 2 OF MFG.II5400775.SIQS MATFINAL UT PART: MATERIAL: HANDLE STEEL STEM ROD BRASS RAIL C.P. BRONZE BODY SIGHT GLASS BRONZE WEAN VALVE 55.2.1 IMPREGNATED TEFLON INDICATOR PLATE STEEL HANDLE LOCK SPRING STEEL MODEL 1000 500-IMM W-1 3/4" 1" 11/4' 11/2" 2" U The AGF Manufacturing Inc. Model 1000 TESTANDRAIN Provides Both The Test Function And The Express Drain Function For A Wet Fire Sprinkler System. U The Model 1000 Complies With All Requirements Of NFPA-13, NFPA-13R, And NFPA-13D. U The Model 1000 TESTANDRAIN Is A Single Handle Bail Valve That Is Light Weight And Compact, Includes A Tamper Resistant Test Orifice, Integral Tamper Resistant Sight Glasses, And Is 300 PSI Rated. U Available In A Full Range Of Sizes From 3/4 102" NPT & BSPT, With All Specifiable Orifice Sizes /8", /i&', 1/2!', 17/321, /" (ELO), 3/4" (ESFR) and K.25. 0 The Orifice Size Is Noted On The Indicator Plate And The Valve Is Tapped For A Pressure Gauge. 0 The Standard Model 1000 TESTANDRAIN Valve Includes A Pressure Gauge Port Tapping And Can Be Ordered With A Relief Valve As A Model 1011 Or lOUT U Locking Kit Available Which Provides Superior Vandal Resistance And Prevents Unintentional Alarm Activation. our New Autoe 0S,L Visit us on the Internet Cd MODEL 1000 300 PSI /A LI1 ER&I'VI 3/4" 1" 11/4" 11/2" 2" 110E.JI11I VIRWIVRKIIE.#mL II'lDlF3U.PII%JI j FROM BRANCH GAUGE BuPROVIDED Ll 't STEEE1 TODRAIN STRMEL OR PIPE TO DRAW EIGHT HAND/STRAIGHT INSTALLATION APPROVALS: LI ULandULCUsted LI FM Approved except 3/4 LI WC-BSA NO. 720-87-SM LI CA.State Fire Marshall A B C 0 E F G H 5 'I,? 1 i/a" 2 3/,3 3/2 4 p1,," r2& 3 i/B" 1 53/,," 39 5 Fe"1 '/2" 37.55,m,,, 2 3/ra" 5545,279 3 /e"3 93.53,18, s/a" 25417,19 6 'a" 20,3,, 115/la 45.30119 4 'e" 117.12,999 F3/dI ii/ 137.JUG8 1 111,3" 43.70,m, 2 p1,3" &8J4Vn 4 i/I' I30.2&,9n 62429,11 5 3 Fe' 5244797 1'/i" 95.29mm, 5 91I3" 14149,997 5 I," 6 p',? issis, 1 ii3 4540,6,, 3 III' 9146,99,, 75.20mm 5/6" 18972,, 3 /o" 98.15mm 2 /e" 66.97mm, 8 '//' 435.63917 10 '? 163.357V,, 1 'ul6" 43.547mm 3 M' BISOn,,,, 511,6 5391,, 2734AU,fl 6'h,o" 3 99.20,2,1 2618" 63.97,90, 81//' 230.659197 10 ,9 27640,9,9 '3/4'Vislve UI listed only. I ULLS1ING 8X8016 JOB NAME: Too Q~Aiir Lem, Wvem, PA 193155 T1(670)246.45061F1(615)2404505 Em2111996055.I27d,911'.06m ___ ARCHITECT: WB61,2*,24014931519.osm MADE 43UA. CONTRACTOR: 3/02 M. Coll, Ik1AlA:jA4L- S.., gJ11102, ji "MI 21 In ORIFICE SIZE AVAILABLE — 3/8 11/16,1/2', 17/32', 0.0(5/2'), ESFR(312'V and K.25 Avolloble or, li/U' t 2' 5120 UnSa only. ;i~ & Fabrication Response Fire Supply & Fabrication Welding Procedure As indicated in 6.5.2.5.2. AWS 822., Specification foe Welding Procedure and Performance Qualification, reflects the Minimum welding qualification requirements needed for welding onto sprinkler systems. The welding procedures and the performance of the welders must be in conformance with AWS B2.1 or other equivalent standard. AWS 82.1 is the American Welding Society's replacement for AWS D1O.9, which was discontinued. As indicated in 6.5.2.5.4, procedures qualified under AWS DIO.9 are still applicable to work on sprinkler systems. 6.5.25.3 Successful procedure qualification of complete joint penetration groove welds shall qualify partial joint penetration (groove/fillet) welds and fillet welds in accordance with the provisions of this standard. 6.5.2.5.4 Welding Procedures qualified under standards recognized by previous editions of this standard ,hall be permitted to be continued in use. 65.2.5.5 contractors or fabricators shall be responsible for all welding.they produce, Contractors or fabricators are directly responsible for qualifying procedures and welders, as well as for the quality of the welds performed by their employees. 6.5.2.5.6 Each contractor or fabricator shall have available to the authority having jurisdiction an established written quality assurance procedure ensuring compliance with the requirements of 6.5.2.4 The requirementsJn 6.5.2.5.6 establish a level of qualification for welders, weld•rnachlne operators and welding contractors. Welding contractors are expected to have a quality assurance procedure established and available for review by the authority having Jurisdiction to verify that the welders aria knowledgeable and capable of conducting the •proper welds described in 6.5.2. The wèldlng:procedure is required to use either AWS 82;1 or other applicable local welding code reqt1rements as a minimum standard. Exhibit 6.25 shOws examples of both acceptable and substandard welding. 6.5.2.6 Records. 6.5.26.1 Welders or weldingmathine opàrators shall upon completion of each welded pipe place their identifiable mark orlabel•ànto.each piece adjacent to a weld. When welding flanges onto pipe, sufficient strength is achieved by: welding the outside of the flange:(hub.e.nd)to the pipe A weld between the end of the pipe and the flange is permitted to seal the cavity between the flange and the pipe to reduce the corrosive activity. The weld thickness Is required to be at.least 1.25 times, the pipe or hub wall thickness, whichever is thinner. 6.5.2.4.5 Tabs for longitudinal earthquake bracing.shall have minimum throat weld thickness not less than 1.25 times the pipe wall thickness and welded on both sides of the longest dimension. 6.5.2.4.6 When welding is performed, the following shall apply: 11 Holes in piping foroutlets shall be cut to the full inside diameter of fittings prior to. welding in place of the fittings. Discs shall he retrieved. . Openings Cut Into piping shall be smooth bore, and.all internal slag and welding residue shall be removed. . Fittings shalf not penetrate the lnternal.diarneter of the piping. Steel plates shall not be welded to the ends of piping or fittings. . . . Fittings .shall not be modified. Nuts, clips, eye rods, angle brackets, orother fasteners shall not be welded toppe or fittings, except as permitted in 6,5.2,2.3 and 6.5,245, Completed welds shall be free from cracks, incomplete fusion, surface porosity greater than 1/16 in. (1.6 mm) diameter, and undercutdeeper than 25. percent of the, wall thickness or 1/32 in. (0.8 mm), whichever is less. completed circumferential butt weld reinforcement shall not exceed 3/32 in. (2.4 mm). Past experience indicates that quality control can be a problem with welded sprinkler piping, which Is the reason for the requirement in 6.5.2;4.6(1). conditions that are not permitted are identified in 6.5.2.2,4. Field experience indicates that need to provide the minimum requirements for the quality of welded work. These requirements are specified in 6.5.2.4.6(1.) through (9). When welded outlets are formed, concerns addressed by these requirements include the foltôw1ng The area of flow must not be restricted; Holes should be cut in a manner that provides for disc retrieval to minimize obstructions in the waterway. Rough edges cause turbulence, which Increases friction loss, and welding residue could Obstruct waterfiow through activated sprinklers. Penetration beyond the internal diameter of the pipe restricts flow and causes turbulence. Procedures listed in 6.5.2.4.6(4) through (7) represent poor welding: practices for fire protectiàn systems and are not permitted by.NFPA 13. The disc retrieval specified in 6.5-2A 69.2) is best ensured by attaching the disc to the piping at the. point at which, it waicut, as indicated in exhibit 614. 6.5.2.5.Quitlficatlons, 6.52.5.1 A welding procedure shall be: prepared and qualified by the contractor or fabricator before any welding is done. 6.5.2.5.2 Qualification of the welding procedure to be used and the performance of all welders and welding operators shall be required and shall meet or exceed the requirements of AWS 82.1, Spec! kationfdr Welding Procedure and Performance Qualification; ASME Boiler and Pressure VesselCocle, Section IX, Welding and Brazing Qualifications, or other applicable qualification standard as required by the authority having Jurisdiction, except as permitted. by The identification mark or label serves to record welds completed by a specific welder. The markor label allows quality control problems or defective materialsto be easlt'y traced if a problem with the weld occurs. It is permissible to mark or label each pipe welded; rather than to mark or label each sprinkler pipe weld. 6.52.62 Contractors or fabricators shaft maintain certified records, which shall be available to the authority having jurisdiction, of the procedures used and the welders or welding machine operators employed by them, along with their well identification. 6.5.2.6.3 Records shall show the date and the results of procedure and performance qualifications. 6.5.3. Groove Joining Methods. ACCURATE WELD TESTING LAB 3451 131St NESS DR. HUNTINGTON BEACH, CA 9249 P11(714)373-3852/ FX (714) 373-3856 WELDING PROCEDURE SPECIFICATION (WPS) Date: 7/18/17 Identification RFS-1-1-SM-7018-2F-1 Company Name RESPONSE FIRE SUPPLY & FABRICATION Supporting PQR no.(s) # 748 Type - Manual (X) Semi-Automatic ( ) Welding Process SMAW Machine( ) Automatic ( ) Backing:.Yes( )No (X) Backing Material (type) N/A. Material Number I Group 1 To material number I Group Material Spec.type and grade A-53 A & B, A-120,A-795, A135 To material Spec. type and grade A-53, A or 13, OR MERIT Fitting Base metal thickness N/A Fillet UNLIMITED Sizes FOR FILLET WELDS Deposited weld metal thickness range .063" to All Sizes Filler metal F No F 4 A no. Spec. no, (AWS) 5.1 Flux tradename N/A Electrode-flux (class) N/A Type N/A Consumable insert: Yes ( ) No (X ) Classifications N/A AWS classification E-7018 Shape N/A Position(s) ofjoint IF & 2F Size N/A Welding progression Up( ) Down ( ) N/A Ferrite No. (When Reqd) N/A PREhEAT: GAS: Preheat tamp, mm. NONE Shielding gas(es) N/A Inter pass temp.. max 500° F. % Composition N/A (Continuous or special heating, where applicable, Flow rate N/A should be recorded) Root Shielding gas N/A POSTWELD HEAT TREATMENT: NONE Trailing gas composition N/A Temperature range N/A Trailing gas flow rate N/A Time range N/A Tungsten electrode, type and size N/A Short-circuiting ( ) Globular ( ) Spray ( ) Electrode wire feed speed range: N/A Stringer bead ( ) Weave bead ( ) Peeling: Yes ( ) No ( ) OiUatitrn • N/A • Standoff Distance N/A Multiple ( ) or single ( X) electrode, Other THIS IS A SADDLE JOINT, OUTLET FITTING ON RUN PIPE Approved for Production by RESPONSEFIRESUPPLY&FABRICATION Employer 'Weld La3crs) Process Filler Metal Class • Din. Polarity Type & Amp Volt Travel Range Range Speed Range. SMAW E-7018 1/8" D.C,E.P. 60-170 Van, MANUAL 19-27 ACCURATE WELD TESTING LAB 5451 BUSINESS DR. HUNTINGTON REACH, CA 92649 PH (714) 3733852 / FX (114) 373-3856 PROCEDURE QUALIFICATION RECORD (PQR) WPS no, used for test RFS-I1- I SM-70 I 8-2F- I Welding process(es) SMAW Company RESPONSE FIRE SUPPLY & FABRICATION Equipment and model (sw) LINCOLN / IDEAL ARC 300 Joint Design Used REINFORCING FILLET WELD (SEE ATTACHED DETAil) Single (X) Double ( ) Weld POSTWELD HEAT 1 RFATM['I%T (2 6 6) NONE Backing Material MATERIAL OF WELD JOINT Temp. N/A Root opening 0-1/81, Root face dimension N/A Time N/A Groove angel 370: Radius (J-U) N/A Other N/A Backing gouging: Yes( ) No ( X) Method N/A GAS (2.6.1) BASE METALS (2.6.2) Gas type(s) N/A Material spec ASTM A-] 35 ERB to MERIT FITTING Gas mixture percentage N/A Type or grade N/A to N/A Flow rate N/A Material no I to material no I Backing gas N/A Group No, I to group no 1 Root shielding gas N/A Thickness 080' Wall to Merit Fitting EBW vacuum ( ) Absolute Pressure ( ) N/A Diameter (pip) 3/411 Merit to 1 1/211 NPS ELECTRICAL CHARACTERISTIC (2 6 8) Surfacing: Material N/A Thickness N/A Electrode extension N/A Chemical Composition N/A Other N/A Standoff distance N/A FILLER METALS (263) Transfer mode(GMAW) N/A Weld metal analysis A no I Electrode diameter tungsten N/A Filler metal I' no F4 Type tungsten electrode WS specification 5.1 Current AC ( ) DCEP ( X ) DCEN ( ) PULSE ( ) AWS Classification E-7018 Heat input N/A Flux class N/A Flux brand N/A FBW beam focus current N/A pulse freq.. N'A Consumable insert: Spec. Class N/A Filament type N/A Shape N/A Supplemental Filler metal Spec. N/A Class N/A Other N/A Non Classified filler metals. N/A TECHNIQUE(2 69) Consumable guide (ESW) Yes ( ) No (X ) Oscillation fn.quency N/A Weak C idth NVA Supplemental deoxidant (EBW) N/A Dwell time N/A POSITOM2 64) String or weave bead STRING Weave width tx/A Position of groove 2F * Fillet N/A Multi pass or single pass(per side) SINGLE Vertical progression Up ( I Down ( ) N/A Number of electrodes 1 * HAS SINGLE BEVEL PREP. ON MERIT FITTING Peening NONE PREHEAT(163)1 Electrode spacing N/A Preheat temp. actual mm. 70° F. AMBIENT Arc timing (SW) N/A Interpass temp.,actual max N/A, SINGLE PASS PAW Conventional (N/A) Keyhole (N/A) lntcrpas cleaning: N/A Pass no Filler Metal size Volts Travel peed(ipm) Filler Metal(ipm) Slope induction Special notes (process etc.) 1 118 t140 18-20 MANUAL NIA N/A NONE Approved for Production RESPONSE FIRE SUPPLY & FABRICATION ION Employer ACCURATE WELD TESTING LAB 5451 BUSINESS DR. HUNTINGTON BEACH, CA 92649 PH (714) 373-3852 / FX (714) 373-3856 WPS # RFS-1-I-SM-7018-2F-1. TENSILE TEST SPECJMENS:SUGGESTED PROCEDURE QUALIFICATION RECORD PQR NO, Type N/A Tensile specimen site N/A Area N/A Groove CX ) Reinforcing bar ( ) Stud welds Tensile test results(Minimum required U fS N/A psi) Specimen No W I Area Max Lead lbs LJTS,psi Type of failure and location 1 N/A N/A N/A WA N/A N/A 2 N/A N/A N/A N/A N/A N/A GUIDED BEND TEST SPECIMENS-SPECIMENS SIZE TYPE RESULT TYPE RESULT N/A N/A N/A N/A N/A N/A N/A N/A MACRO EXAMINATION RESULTS: Horizontal Saddle Joint Macro Etch I SATISFACTORY 3.- N/A 5.-N/A SHEAR TEST RESULTS -FILLETS- S I N/A 3.- N/A IMPACT TEST SPECIMENS: N/A Type: N/A Test Temperature: N/A 2.- SATISFACTORY 4,- N/A 6.- _N/A 2.- N/A 4.- N/A Size: N/A Specimen location: WMweid metal; BM=base metal; l{AZheat affected zone 'rt'or nrrri Ire. Welding Position Specimen Location Energy absorbed (ft. lbs) Ductile fracture area percent Lateral expansion (mils) N/A N/A N/A N/A N/A N/A N/A N/A N/A NIA N/A N/A N/A N/A N/A IF APPLICABLE Hardness tests: ( ) Values N/A Acceptable ( ) Unacceptable Visual (special weldments 2.4.2) ( X ) Acceptable ( X ) Unacceptable I Torque ( ) psi N/A Acceptable ( ) Unacceptable Proof test ( ) Method N/A Acceptable ( ) Unacceptable Chemical analysis ( ) N/A Acceptable ( ) Unacceptable Non-destructive exam ( ) Process N/A Acceptable ( ) Unacceptable ROOT BREAK TESTS: # I - SAT., # 2 -SAT. Acceptable (X) Unacceptable ( I Mechanical Testing by ACCURATE \VELI) TESTING LAB. Lab No. # 748 Ron; WS ciT' Per: J ' Test Date: 7/20/17 Qc "PI 611112018 RONALb S. MOBLEY We certify that the statements in this record are correct and that the test welds were prepared, welded and tested in accordance ® of the American Welding Society Standard for welding procedure and Performance Qualification AWS B2.1 AVIS CWI 88060711 OC1 EXP. 811/2021 Welder: ARMANDO ZAVALA .l.D # AZ - 2275 Qualifier: RESPONSE FIRE SUPPLY & FABRICATION Reviewed by: Date: Approved by; ACCURATE WELD TESTING LAB 5451 BUSINESS DR. HUNTINGTON BEACH, CA 92649 PH 714 373-3852 FAX 714 373-3856 Sample Form C: Typical Contractor's Welder Qualification Tests Record. This form or its equivalent shall be used to document the results of welder qualification tests and should be accompanied by the welding procedure record Welders name: ARMANDO ZAVALA ID. # A Z - 2275 Title of standard governing qualification AWS 132 1 Welding procedure specification no RFS-1-1-SM-7018-2F-1 Test no. Welding process(es) SMAW Base metal A 135 GR B to Fitting P-number 1 to P-number 1 Pipe diameter 3/4 • on 1 1/2' Group number I Filler metal Spec. 5.1 F#4 Pipe wall thickness .080" Wall to Merit Fitting Classifications E - 7018 A-number 1 Filler metal size 1/8" No. of beads or passes 1 Approx. volts 19 -26 Approx. amps 60 -170 Pipe position IG ( ) 2G ( ) * 5G ( ) 6G ( ) iF ( ) 2F (X) 4F ( ) 5F Direction of welding N/A (Uphill, downhill) Electrical Characteristics D C.E.P. X D C E N A C Gas shielding Gas(es) N/A Flow rate N/A Backing: consumable Insert (class and type) N/A Backing ring N/A Gas(es) N/A Flow rate: N/A Volume: N/A Test Results * MERIT FITTING HAS BEVEL Visual inspection results SATISFACTORY Radiographic results: N/A Radiograph Radiograph no Results no Results N/A N/A N/A N/A Sectional or macrostructural examination or fillet weld fracture test results QUALIFIED BY PQR TEST RESULTS 1 MACRO: SATISFACTORY * 3 MACRO: SATISFACTORY * 2 MACRO SATISFACTORY * 4 MACRO SATISFACTORY Guided-bend test results N/A Type Specimen no Results Type Specimen Results Face NIA Face N/A Root N/A Root N/A Side N/A Side N/A Pressure bend test results: N/A Special tests N/A Test conducted by TESTING LAB Date 7120/17 lox RAnz1A RA-&. RONALD S18L Lab no #748 60711 QC1 EXP. 6/1/2018 Organization: RESPONSE FIRE SLJPPLY& FABRICATION Signed: Date: Ronald SMobley AWS CM 88060711 Oci EXP. 8/1/2021