Loading...
HomeMy WebLinkAbout1860 MARRON RD; ; FA150072; PermitCity of Carlsbad Fire Alarm Permit Permit No: FA150072 Job Address: 1860 MARRON RD Permit Type: FALARM Parcel No: 1563011600 Lot #: 0 Reference No.: PC #: Status: ISSUED Applied 11/12/2015 Approved: 11/18/2015 Issued: 11/18/2015 Inspector: Project Title: SOUP PLANTATION FA TI Applicant: INTERFACE SECURITY SYSTEMS 3750 SCHAUFELE AVE #200 LONG BEACH, CA 90808 362-221-9957 Owner: P K I NORTH COUNTY PLAZA LP C/O KIMCO REALTY CORP 3333 NEW HYDE PARK RD #100 NEW HYDE PARK NY Fees ($) Add'I Fees ($) Total ($) Balance ($) 314 0 314 0 November 4, 2015 terface 3750 Schaufele Ave. Suite 125 Long Beach, CA 90808 Phone: 949-474-0555 Fax: 949-474-5511 www.interfacesys.com Project Name: Souplantation GFR-007 Project Address: System Type: Project #: 1860 Marron Rd. Fire Sprinkler Monitoring System 7619 Carlsbad, CA. 92008 PROJECT SUBMITTAL DOCUMENTS Section 1 - License & U.L. Certification Section 2 - Eauipment Specification Datasheets DATA SHEET# PART# DESCRIPTION CSFM# Vista-128FBP Honeywell Fire Alarm Control Panel 7165-1645:0123 6160CR-2 Keypad, Commercial Fire Alphanumeric 7165-1645:0123 NP-1812B Yuasa 12V, 17.2 AH Battery N/A IGSMCFP4G Honeywell GSM/IP Comunicator 7300-1645:0199 4193SN V-Plex Mini Monitor Module 7165-1645:0123 5140MP5-1 Fire Pull Station 7150-1645:0118 2W-B System Sensor Photo Smoke Detector With 2-Wire Base 7272-1653:0152 Section 3 - California State Fire Marshal Listing Sheets Enclosed in this Booklet are the data sheets describing the equipment Interface Security Systems is proposing to furnish. Kayleen Smart Interface Security Systems Designer FA150072 LICENSE & UL CERTIFICATIONS PreparedbT 00 00 ENGINEERING A. SAF5 & SECURE PUTURE TODAY Section 1 STATE OF CALIFORNIA %0"--o'*ONTR ACTORS ST AT EILI CENSE f71BOARD Pursuant to Chapter 9 of Division 3 of the Business and Professions Code and the Rules and Regulations of the Contractors State License Board, the Registrar of Contractors does hereby issue this license to: INTERFACE SECURITY SYSTEMS LLC dba INTERFACE SYSTEMS License Number 469046 to engage in the business or act in the capacity of a contractor in the following classification (s): Li C10 - ELECTRICAL Witness my hand and seal this day, February 9, 2015 David Dias, Board Chair Issued February 5, 1985 CERTIFIED COPY This license is the property of the Registrar of Contractors, is not transferable, and shall be returned to the Registrar upon demand when suspended, revoked, or invalidated for any reason. It becomes void if not renewed. Cindi A. Christenson, Registrar of Contractors 3L-24 (REV. 0813) AUDIT NO: 584727 State Of California 9 CONTRACTORS STATE LICENSE BOARDS (uunwr ACTIVE LICENSE 469046 ErWY LLC INTERFACE SECURITY SYSTEMS LLC OBA INTERFACE SYSTEMS Cl 0 08/31/2015 wcslb.cagov UL LLC CERTIFICATE OF COMPLIANCE COVER PAGE MS K WEINRICH Applicant Subscriber No: 750680-001 INTERFACE SECURITY SYSTEMS L L c Service Center Number: 1 3773 CORPORATE CENTRE DR Service Contract No: - EARTH CITY MO 63045-1130 ACTIVE LISTINGS CCN File No. Vol. No. UUFX S3521 1 UUJS S5402 1 CPVX BP6545 1 Listed Service From: EARTH CITY, MO Alarm Service Company: Service Center: INTERFACE SECURITY SYSTEMS L L C INTERFACE SECURITY SYSTEMS L L C 3773 CORPORATE CENTRE DR 3773 CORPORATE CENTRE DR EARTH CITY MO 63045-1130 EARTH CITY MO 63045-1130 UL ' Applicant ID No: 750680-001 Service Center No: I Expires: 2016-03-31 CERTIFICATE OF COMPLIANCE THIS IS TO CERTIFY that the Alarm Service Company indicated below is included by Underwriters Laboratories Inc. (UL) in its Product Directories as eligible to use the UL Listing Mark in connection with Certificated Alarm Systems. The only evidence of compliance with UL's requirements is the issuance of a UL Certificate for the Alarm System and the Certificate is current under UL's Certificate Verification Service. This Certificate does not apply in any way to the communication channel between the protected property and any facility that monitors signals from the protected property unless the use of a UL listed or Classified Alarm Transport Company is specified on the Certificate. Listed Service From: EARTH CITY, MO Alarm Service Company: (750680-001) Service Center: (750680-001) INTERFACE SECURITY SYSTEMS L L C INTERFACE SECURITY SYSTEMS L L C 3773 CORPORATE CENTRE DR 3773 CORPORATE CENTRE DR EARTH CITY MO 63045-1130 EARTH CITY MO 63045-1130 The Alarm Service Company is Listed in the following Certificate Service Categories: File - Vol No. CCN Listing Category BP65451 CPVX [Burglar Alarm Systems] Central Station S35211 UUFX [Signal and Fire Alarm Equipment and Services] (Protective Signaling Services) Central Station S54021 UUJS [Signal and Fire Alarm Equipment and Services] (Protective Signaling Services) Local, Auxiliary, Remote Station and Proprietary ***THIS CERTIFICATE EXPIRES ON 20160331*** "LOOK FOR THE UL ALARM SYSTEM CERTIFICATE" LUId CERTIFICATE OF COMPLIANCE COVER PAGE RICHARD JOHNSON Applicant Subscriber No: 743925-001 INTERFACE SECURITY SYSTEMS L L C, DBA Service Center Number: 1 INTERFACE SYSTEMS Service Contract No: - 3750 SCHAUFELE AVE STE 200 ACTIVE LISTINGS LONG BEACH CA 90808-1779 CCN File No. Vol. No. CVSG BP8540 1 UUJS S3388 1 CPRH BP8539 1 CRZH BP9641 1 UUFX S7279 1 Listed Service From: LONG BEACH, CA (LONG BEACH) Alarm Service Company: Service Center: INTERFACE SECURITY SYSTEMS L L C, INTERFACE SECURITY SYSTEMS L L C, DBA DBA INTERFACE SYSTEMS INTERFACE SYSTEMS 3750 SCHAUFELE AVE STE 200 3750 SCHAUFELE AVE STE 200 LONG BEACH CA 90808-1779 LONG BEACH CA 90808-1779 Applicant ID No: 743925-001 Service Center No: I Expires: 2016-03-31 CERTIFICATE OF COMPLIANCE THIS IS TO CERTIFY that the Alarm Service Company indicated below is included by Underwriters Laboratories Inc. (UL) in its Product Directories as eligible to use the UL Listing Mark in connection with Certificated Alarm Systems. The only evidence of compliance with UL's requirements is the issuance of a UL Certificate for the Alarm System and the Certificate is current under UL's Certificate Verification Service. This Certificate does not apply in any way to the communication channel between the protected property and any facility that monitors signals from the protected property unless the use of a UL listed or Classified Alarm Transport Company is specified on the Certificate. Listed Service From: LONG BEACH, CA (LONG BEACH) Alarm Service Company: (743925-001) Service Center: (743925-001) INTERFACE SECURITY SYSTEMS L L C, DBA INTERFACE SECURITY SYSTEMS L L C, DBA INTERFACE SYSTEMS INTERFACE SYSTEMS 3750 SCHAUFELE AVE STE 200 3750 SCHAUFELE AVE STE 200 LONG BEACH CA 90808-1779 LONG BEACH CA 90808-1779 The Alarm Service Company is Listed in the following Certificate Service Categories: File - Vol No. CCN Listing Category BP85391 CPRH [Burglar Alarm Systems] Bank BP96411 CRZH [Burglar Alarm Systems] National Industrial Security Systems BP85401 CVSG [Burglar Alarm Systems] Mercantile S72791 UUFX [Signal and Fire Alarm Equipment and Services] (Protective Signaling Services) Central Station S33881 UUJS [Signal and Fire Alarm Equipment and Services] (Protective Signaling Services) Local, Auxiliary, Remote Station and Proprietary ***THIS CERTIFICATE EXPIRES ON 20160331*** "LOOK FOR THE UL ALARM SYSTEM CERTIFICATE" EQUIPMENT SPECIFICATION DATASHEETS Prepared by: c00 TfAnl N: EMOINEERINO ASA?5 & SECURE FUTURE TODAY Section 1 !4 - Honeywell VISTA-I 28FBPNI 28FBP-24 COMMERCIAL PARTITIONED FIRE AND BURGLARY ALARM CONTROL PANEL Now U1864 9th Edition Approved Designed to integrate seamlessly with CCTV, access control and Honeywell's full range of fire and burglary components, the new VISTA-1 28FBP provides the ultimate protection of life and property. The UL Listed commercial fire and burglary control panel supports up to eight partitions and up to 128 zones/points using hardwired, wireless and V-Flex® addressable technologies. A diverse line of Honeywell initiating devices, notification circuits, communication devices, keypads, HF receivers and relays are also supported. The VISTA-i 28FBP has been designed to mount quickly and easily in an attack resistant cabinet, and is available in 12V and 24V models. FEATURES Eight hardwired zones standard, expandable to 120 V-Flex addressable points/zones or 128 wireless points/zones Can control eight separate areas independently (8 partitions) Supports commercial wireless fire and burglary devices Stores up to 512 events Accommodates 150 user codes and up to 250 access card holders using VistaKey Supports V-Flex addressable VistaKey access control (1 to 8 doors) Two on-board notification (bell) circuits delivering 2.3A @ 12V or 3.4A @ 24V Automatic smoke detector sensitivity maintenance testing Four-wire smoke reset using onboard J2 output trigger Supports Dynamic Signaling for AlarmNet Communicators Supports Remote Control via the Internet* Supports Internet Alarm Reporting* Supports Graphical User Interface Consoles Listed to UL864 9th Edition Upload/download via Ethernet* Carbon monoxide (CO) zone support When used with AlarmNet devices. VISTA-I 28FBPNI 28FBP-24 Honeywell COMMERCIAL PARTITIONED FIRE AND BURGLARY ALARM CONTROL PANEL ADDITIONAL FEATURES Notification Appliance Circuits (two): - Up to 50 two-wire glassbreak detectors - Supervised by control for - Programmable on zone eight check-in signals -Temporal code compliant Patented addressable V-Plex polling - Tamper protection for transmitters - Individually silenceable loop technology - Individually assignable up to Programmable on-board auxiliary relay - Supports 120 two-wire zones points eight partitions False alarm reduction features: - Global polling technology for - Supports commercial - Exit error logic faster processing wireless smoke detectors - Exit delay reset - Supervised by panel Access Control integration - Zones individually assignable to — Full integration with PassPoint - Cross zoning partitions, notification circuit (bell) Access Control System - Call waiting defeat output or auxiliary relay Complete Gateway interface of VISTA and access functions - Recent close report —4,000 ft. capability without the use of shielded cable Up to eight doors using VistaKey Supports commercial hardwired, V-Plex Access Control addressable V-Plex polling loop and - Extender/Isolation bus modules wireless zones Event reporting - Eight zone - Class A and B Hardwired zones expander module Local printer of access or VISTA - Provides eight style B hardwired zones related events - EOLR supervised for Fire and - Eight zone - Class B expander Communication UL burglary installations module - Phone mapping by zone - Supports N.O. or N.C. sensors - One zone supervised contact response type monitor module - Individually assignable to any - Panel operation during eight partitions UL Listed wireless expansion download 16 - Supports up to 128 wireless - Up to 8-two-wire smoke detectors zones/points each on zone one and two (64 total) 32 Honeywell SPECIFICATIONS Applications • Fusing: Battery input, aux. and The VISTA-i 28FBP control is well notification (bell) circuit outputs are suited for a variety of applications as protected using PTC circuit protectors. an integrated fire and burglary control. A All outputs are power limited. diverse line of Honeywell initiating devices Optional 24-volt power supply, PS 24 supports this extremely powerful control, supplies two 24 VFW, 1.7A full wave Some of the applications supported are: rectified, unfiltered outputs medical and professional buildings, Main Dialer churches or synagogues, office buildings, schools, strip malls, larger residences Line seize: Double Pole and factory or warehouse environments. Ringer equiv.: 0.7B Formats: ADEMCO Low Speed, Primary power: 1 8VAC @ 72VA ADEMCO 4+2 Express, ADEMCO High Honeywell No. 1451 Speed, ADEMCO Contact ID, Sescoa and Radionics Control panel quiescent current draw: 300mA • Dual phone line capability (using Backup battery: 5140DLM module) - 12VDC, 12AH min to 34.4AH max Cabinet dimensions - Lead acid battery (gel type) • 18" H 14.5" W 4.3" D Alarm power: 12VDC, 1.7A max for Environmental each notification (bell) circuit output Total 2.3A © 12V • Storage temp: 140 F to 158° F Aux. standby pwr: 12VDC, 1 A max (100 C to 70° C) Total power: 2.3A at 12VDC, 3.4A at • Operating temp: 32° F to 122° F 24VDC from all sources (QO C to 50° C) Standby time: 24 hours with 1A • Humidity: 85% RH standby load using 34.4AH battery EMI: Meets or exceeds the following requirements: - FCC Part 15, Class B Device - FCC Part 68 - IEC EMC Directive Agency Listings UL609 Grade A Local Mercantile Premises and Mercantile Safe and Vault UL61 1/1610 Grades A, M, Central Station UL365 Grades A, M Police Connect UL864/NFPA72 Local, Central Station and Remote Station UL985 Factory Mutual California State Fire Marshal MEA CAN/ULC S304 - Central and Monitoring Station Burglar Alarm Unit CAN/ULC S527 - Central Unit for Fire Alarm Systems CAN/ULC S303 - Local Burglar Alarm Unit CAN/ULC S525 - Audible Signal Appliances VISTA-I 28FBPNI 28FBP-24 COMMERCIAL PARTITIONED FIRE AND BURGLARY ALARM CONTROL PANEL COMPATIBLE DEVICES Auxiliary Devices 6160C1R-2 - Red Alpha Keypad 4204 - Relay Module, four form C contacts 4204CF - Two supervised output circuits 5881 Series RF receiver 5883H RF receiver 6220S - System printer used with 4100SM serial module 61600R-2 - Red Fire Keypad 6160 - Burglary Keypad Two-Wire Smoke Detectors Conventional System Sensor ESL DSC Horn/Strobes System Sensor Wheelock Gentex Manual Pull Stations 514OMPS-1 514OMPS-2 V-Plex (Addressable) Devices 4208U Loop Expansion Module - eight zones 4101SN Single Relay/Zone Module 4208SNF Class NB Expander Module 4190SN Remote Point Module - two zones 4193SN Two-Zone Serial Interface Module VSI Module 4293SN One-Zone Serial Interface Module V-Plex Extender/Isolation Modules 4297 Extender/Isolator Module VSI Isolator Module V-Plex Smoke Detectors: 5193SD 5193SDT V-Plex Passive Infrared Detectors 998MX 152500SN DT7500SN V-Plex (Addressable) Contacts 4939SN-WH 4944SN-WH 4959SN V-Plex Glassbreak Detectors FG1625SN Optional 24V Power Supply PS24 - 24V power supply - 3.4A Commercial Wireless Devices 5808W3 - Photoelectric Smoke/Heat Detector 5806W3 - Photoelectric Smoke Detector 5809 - Wireless Heat Detector 5817CB - Wireless Commercial Transmitter 5869 - Hold-Up Transmitter 5881 ENHC - RF Receiver 5883H - RF Receiver Access Control VistaKey V-Plex (addressable) Access Control VistaKey-SK Starter Kit VistaKey-EX Expansion Kit Alarm Communications 7845i-ENT - Internet/Intranet Communicator 7845GSM - Digital Cellular Communicator 7845i-GSM - Internet and Digital Cellular Communicator GSMCF/iGSMCF - Commercial Fire Communication Kits (when available) Product specifications subject to change. ORDERING V128FBP-9 Commercial Fire and Partitioned Burglary Alarm Control Panel 12V Model V128FBP9-24 Commercial Fire and Partitioned Burglary Alarm Control Panel 24V Model For more information: www.honeywell.com/security/hsc Automation and Control Solutions Honeywell Security & Communications Honeywell 2 Corporate Center Dr. Suite 100 Melville, NY 11747 LN5TA128F5P0/D 1.800.467.5875 September 2009 www.honeywell.com 0 2009 Honeywell International Inc. 61 6OCR-2 COMMERCIAL FIRE ALPHA KEYPAD UL864 REV 9 LISTED The 61 6OCR-2 is an addressable remote keypad intended for use in commercial fire applications with Honeywell's commercial fire control panels. The keys are continuously backlit for convenience and easy visibility. The LCD display = Fitt FRIQ AWAY WAY * PARK IL is backlit only when a key is depressed*, or when the system is in alarm or trouble condition. *Note. The LCD may be programmed to remain on at all times (see panel instructions for details). FEATURES Four programmable function keys Built-in sounder Seven Status LEDs - Armed (Red) - Ready (Green) - Power (Green) - Fire Alarm (Red) - Silenced (Yellow) - Supervisory (Yellow) - Trouble (Yellow) Large easy-to-read display Red removable door Physical 5.250" W x 7.437" H x 1.312" D SPECIFICATIONS Sounder High-quality speaker Electrical 45mA standby 1 60mA in alarm (sounder, back light and LED on) Compatibility Supports Control Panels - VISTA-32FB Rev 5 and higher - VISTA-1 28FBP Rev 4 and higher - VISTA-250FBP Rev 4 and higher UL/CUL and residential Listed for commercial fire and burglary installations. To be employed with manufacturer's listed control units as indicated in the installation instructions. Product specifications subject to change. ORDERING 6160CR-2 Commercial Fire Alpha Keypad For more information: www.honeywell.com/security/hsc Automation and Control Solutions Honeywell Security & Communications 2 Corporate Center Dr. Suite 100 Melville, NY 11747 1.800.467.5875 www.honeywell.com U6160CR2OID September 2009 0 2009 Honeywell International Inc. Honeywell Terminals NP batteries are manufactured using a range of terminals which vary in size and type. Please refer to details as shown. Operation in any Orientation The combination of sealed construction and Yuasa's unique electrolyte suspension system allows operation in any orientation, with no loss of performance or fear of electrolyte leakage. Valve Regulated Design The batteries are equipped with a simple, safe, low pressure venting system which releases excess gas and automatically reseals should there be a build up of gas within the battery due to severe overcharge. Note. On no account should the battery be charged in a sealed container. General Specifications Nominal Capacity (Ah) NPI8-12 20hrt0 1.75vpc300C 17.2 lOhrto 1.75vpc201C 16 5hrto 1.70vpc200C 14.5 lhrto 1.60vpc20°C 10.3 Voltage 12 Energy Density (L20hr) 94 Specific Energy (w-kg 20hr) 38 Int. Resistance (m.Ohms) 11 Maximum discharge (A) 112 Short Circuit current (A) 500 Dimensions (mm) Length 180 Width 76 Height overall 167 Weight (Kg) 6.2 Terminal E Layout 2 Terminal Torque Nm - NP SERIES -NPI 8-12 Reliability is your Security Utilizing the latest advance design Oxygen Recombination Technology, Yuasa have applied their 80 years experience in the lead acid battery field to produce the optimum design of Sealed Lead Acid batteries. FEATURES Superb recovery from deep discharge. Electrolyte suspension system. Gas Recombination. Multipurpose: Float or Cyclic use. Usable in any orientation. Superior energy density. Lead calcium grids for extended life. Manufactured World wide. Application specific designs. Technical Features Sealed Construction Yuasa's unique construction and sealing technique ensures no electrolyte leakage from case or terminals. Electrolyte Suspension System All NP batteries utilize Yuasa's unique electrolyte suspension system incorporating a microfine glass mat to retain the maximum amount of electrolyte in the cells. The electrolyte is retained in the separator material and there is no free electrolyte to escape from the cells. No gels or other contaminants are added. Control of Gas Generation The design of Yuasa's NP batteries incorporates the very latest oxygen recombination technology to effectively control the generation of gas during normal use. Low Maintenance Operation Due to the perfectly sealed construction and the recombination of gasses within the cell, the battery is almost maintenance free. Terminals Bolt fastened terminal E I 2 0,1 12 0.2-si -k I s.s INCH =MM T7 .472 12.00 - t - 453 433 11.50 11.00 Fol : .079 2.00 11 - Layout 2 G NP SERIES — NPI8-12 Lead Calcium Grids The heavy duty lead calcium alloy grids provide an extra margin of performance and life in both cyclic and float applications and give unparalleled recovery from deep discharge. Long Cycle Service Life Depending upon the average depth of discharge, over a thousand discharge/charge cycles can be expected. Float Service Life The expected service life is five years in float standby applications. Separators The use of the special separator material provides a very efficient insulation between plates preventing inter-plate short circuits and prohibiting the shedding of active materials. CYCLIC RECHARGE REGIME LILIOOIISSS 51v,tyC.nwg. r17 0.25 cl!N. H 0.15 II V \ + IS 12 NP DISCHARGE CHARACTERISTICS CURVES AT 25C (77°F) FOR FOR v 5040 C - 011.00662.31? 23*12104 0l SaRI baSal? 22 SAlTER? BATTERY POP AT2rO)Ffl, 52.311 60 IH 5.5 s, 11kI I - NNI \ .450.0 5.0 *.0 4.0 - - - - - - - - MINUTES IlIST004GO TIME Nouns FLOAT SERVICE LIFE NP RANGE 5031150 NIA h.OA1INO 001600 2.370050 )AH.) AVGIIEPOTTEMPEPAUISE OLYC 000T0 7201 j 20- LIFE (YEARS) Long shelf Life The extremely low self discharge rate allows the battery to be stored for extended periods up to one year at normal ambient temperatures with no permanent loss of capacity. Operating Temperature Range The batteries can be used over a broad temperature range permitting considerable flexibility in system design and location. Charge — 15°C to 50°C Discharge - 20°C to 60°C Storage — 20°C to 50°C (fully charged battery) SELF DISCHARGE CHARACTERISTICS 10)100 - —z•-• ---:--- - ---+---_ -- 25 4F0 )104b irO 60" -- 0 0- —I- 0 0 9 2 5 10 STORAGE BL11. MONTH?) FLOAT CHARGE CHARACTERISTICS L2 0.PSCA - 2.27SVPC CONSTANT VOI.TAGE CHARGING (10) oCR) VI AT 20C 168 F) '0nI 51 100 0.25 7.50 I. 64 . 100 0.20] CHARGE VOUTAQY ISO 0.151 SO I 6.50 - AFTER I00%OISLCHA060 3.0 AFTER 106 DISCHARGE 12.0 COARGIIAG 0 2 4 S 8 10 12 14 IT IN 20 00200ING TIME (010095) TYPICAL DISCHARGE CHARAC- TERISTICS NP RANGE CYCLE SERVICE LIFE IN RELATION TO DEPTH OF DISCHARGE '05 1NGCOWIrION3 DISGIIRIOOF COlORS NI 0.170 RIS.p. (IsV I.OVICEU 002604510 CURRENT 0.090 2,69. CHARGING VOI.LIME 'ORIROF DISC)4HJS300 CAPACITY lAWS) AMBIENT IFMPERAT000H 20002000 )000F TO 7r0) — —- (Or. 110% 3Cr, DEPT 000 - 000 01 015CR ROE ROUSER OF CYCI. ES Vi Distributed by YUASA 2901 Montrose Ave Laureldale, PA 19605 www.yuasabatteries.com Registered number 1548820 Cat. No] NP7-12 January08 I 1GSMCFP4G INTERNET AND 4G COMMERCIAL FIRE COMMUNICATOR UIASMiIL The IGSMCFP4G is a UL approved dual technology fire alarm communicator that offers contact ID reporting with select VISTAS control panels. It offers three selectable reporting paths which include: cellular only, IP only, or IP primary/cellular backup. The iGSMCFP4G transmits all VISTA control panel events via Contact ID to the AlarmNetO Network Operating Center for routing to the assigned central station receiver. The state of the art AlarmNet Network Operating Center Is fully redundant and monitored 24/7. AdarrnNet has the ability to route messages using AlarmNet-i and 800 PLUS services, providing true redundancy and multi-path message delivery. The iGSMCFP4G meets UL 864 requirements and provides programmable supervision options to meet NFPA72 2010 and 2013 standards using single or dual technologies. FEATURES Single or Dual Path Communications - Communicates using Internet, Cellular, or both Multi-GSM Platform Compatibility - 2G, 30 and 40 - Operates over the following communication protocols: HSPA+ (40), HSPA (HSDPA & HSUPA) (3G), EDGE (20), GPRS (20) IP Communications - Works over any type of customer provided Ethernet 10/100 - Base network connection (LAN or WAN), DSL modem or cable modem - Supports both dynamic (DHCP), or public and private static IP addressing Full Contact ID or ADEMCO High-Speed Reporting - Contact ID reporting using ECP mode with compatible Honeywell control panels 256-bit AES Encryption - Advanced encryption standard used for secure communications Upload/Download - Available with select Honeywell control panels. Requires Compass version 1.5.8.54a or higher. Diagnostic LEDs - Provide signal strength and status indications QOS - Quality of Service diagnostics via AlarmNet supply vital Information Including when a message was received, battery voltage, input voltage, signal strength and message path Web-Based or Local Programming - Allows complete Interactive programming from AlarmNet Direct.https://services.alarmnet.com or local programming with 7720P hand-held programmer iGSMCFP4G INTERNET AND 4G COMMERCIAL FIRE COMMUNICATOR SPECIFICATIONS Mechanical: - Dimensions: 15,0 H x 12.75' W x 3.0' D -Weight: 10 lbs. input Power: 12VDC supplied by the control panel Current Drain: 1 90m standby, 215mA active RF Frequency: - 2G GSM/GPRS/EDGE Quad Band, 850/900/1800/1900 MHz - 3G/4G UMTS/HSPA+ Band V, Band II RF Output Power: -20 GPRS +33 dBm, GMSK modulation - EDGE +27 dBm, 8-PSK modulation - 3G UMTS +24 dBm, QPSK modulation - WCDMA +24 dBm, QPSK modulation -40 HSPA+ +24 dBm, 64 QAM modulation - WCDMA +24 dBm, 64 QAM modulation Ethernet: - Network Standard: IEEE 802.3u compliant - Data Rate: 10 Base-T/100 Base-T with auto detect - Ethernet Cable: CAT5 (min), MDI/MDI-X auto crossover Environmental: - Operating temperature: 32°F to 120.2°F (0°C to 49°C) - Storage temperature: -40°F to 158°F (-40°C to 70°C) - Humidity: 0 to 85% relative humidity, non-condensing - Altitude: to 10,000 feet operating, to 40,000 feet storage Ustings: - UL 864 - Standard for Control Units and Accessories for Fire Alarm Systems UL Compatible Control Panels: - VISTA-32FB - VISTA-32FBT - VISTA-1128FBP - VISTA- 1 28FBPT - VlSTA-250FBP - VISTA-2506PT - FA1 670C (First Alert Professional) - FA1 670CT (First Alert Professional) - FA1 700C (First Alert Professional) - FA1 700CT (First Alert Professional) ORDERING IGSMCFP4G Internet and 4G Commercial Fire Communicator For more Information: www.honeywell.com/securlty Automation and Control Solutions Honeywell Security Products Americas 2 Corporate Canter Dr. Suite 100 P.O. Box 9040 Melville, NY 11747 1.800.467.5875 LJIsSMcFP400/D June 2014 www.honeywell.com 0 2014 Honeyei Internellonal Inc. IriAi1 V-Flex is the patented polling loop technology that literally defines price and performance on a simple pair of wires. By using two wires instead of four, V-Plex offers significant advantages over home run wiring or the conventional four-wire multiplex—providing economical expansion of peripheral devices and point identification to your central monitoring station. The V-Plex® Advantage THE INDUSTRY'S - - - - LEADING ADDRESSABLE Benefits TECHNOLOGY Reduced Costs Since each V-Flex sensor can be installed using two wires for power and data—including existing wiring in many cases—costs are substantially reduced. Reduced Power Consumption V-Flex devices draw minimal amounts of current, minimizing the need for auxiliary power supplies. Fast, Accurate Identification and Response Point ID allows you to quickly and easily pinpoint the source of alarm or trouble from the keypad and communicate the information to the proper authorities—and lets you bypass protection at any specific point. Reduced Time and Labor V-Flex offers a labor and time-saving maintenance feature that gives you the ability to diagnose and pinpoint defects. As a result, installation and service professionals can arrive at the site already knowing the exact location of the problem. Service calls become much more efficient, saving you the time and labor costs associated with repeat visits. Reduced Maintenance Costs V-Flex can initiate functional smoke detector testing from a VISTA-32FB, VISTA-1 28FBF or VISTA-250FBP series system keypad—automatically logging results locally and sending them to a monitoring center. This drastically reduces system maintenance costs when annual tests or inspections are performed. Honeywell's V-Flex addressable technology offers many new and exciting innovations while fully supporting existing addressable loop products. You'll experience efficiencies in installation and reliability that will add up quickly on your bottom line. Begin experiencing the V-Flex advantage today! 11 ACCESSORIES DT7500SN V-Plex DUAL TEC Motion Sensor = 35' or 50 (urn or 15m) lenses Pattern containment and pattern shaping through K-Band microwave technology 0, 50, 100 lbs (0, 23, 45 Kg) selectable pet immunity with optional lens 51935D/5193SDT One Piece Photoelectric Smoke Detector - • • 5193SDT features (1 350F/570C) heat sensor 4959SN Addressable ' Overhead Door Contact Rugged aluminum housing and adjustable L bracket type magnet Standard gap: 2' (51 mm) Tamper 4193SN/4293SN Micro-miniature V-Plex Adapter Makes any hardwired device V-Flex ready () • Built-in serial number for addressing One supervised, one unsupervised zone 1S2500SN V-Plex PIR Motion Sensor .35 or 50' (urn or 15m) lenses 0, 40, 80 lbs (0, 18, 36 Kg) selectable pet immunity with optional lens 269SN V-Plex Holdup Switch I j Fully supervised Reset key for testing and reset of alarm Stainless steel protective cover 4939SN Addressable Surface Mount Contact Traditional '39" style with snap on cover to conceal mounting screws Standard gap: 1.25' (32mm) 5(1 .5m) CL II jacketed cable 41905N Two Zone Remote Point Module DIP switch programmable Left Zone-EOLR supervised, open or closed circuit sensors Right Zone-unsupervised, closed circuit sensors - FG1625SN FlexGuard FlexCore signal processor Selectable sensitivity Easy installation with - - FG-701 Tester No minimum range 25 (9.6m) max range 4191SN-WH Recessed 1/2' (12.7mm) diameter case Standard gap: 7/8" (22mm) Programmable recessed contact with built-in RPM (Remote Point Module) Also available with steel door adapter 4101SN Relay Module Form C contacts rated at 2A, 28VACNDC with contact supervision 0. 61.0.1 • One class B B/style B EOLR supervised aux. input zone Operating and power and communication with control via V-Flex loop 4208SNF Universal I Class A & Class B Expander Module Provides up to six class B supervised zones ' and converts two panel zones to class A supervised zones Powered from addressable loop or DC power supply Serial number addressing via DIP switch 4297 Polling Loop Extender Module Isolates and protects different areas of protection Extends loop distance Separate DC input, no loop current drain 4208SN Universal Eight Zone Remote Point Module Remote expansion zone module 'Supports serial - number application VISTAKEY Access Control Now, you can quickly and easily add access control every time you install a VISTA - —. commercial security system. Vistakey maximizes security investments by integrating access control, intrusion detection and fire detection into a single system. You can offer your customers 1-15 doors of seamless integration, and a unique combination of security and access control features: Arms and disarms security system with access card Conveniently connects to the V-Plex bus Tracks employee door entry and locks/unlocks doors on schedule Restricts access based on job function, time or location Events can be recorded to the VISTA event log; printer optional VPLEX-VSI V-Plex Short Isolator Detects and isolates polling loop branches with complete or resistive shorts, and overload or defective polling loop devices on initial power up Can be used to isolate burglary devices from fire devices, increasing life safety and protection LED indicator reduces troubleshooting time and maintenance costs Powered directly from the V-Plex two-wire polling loop Can be placed on any major or minor branch in any configuration on the polling loop For more information: www.honeywell.com/security/hsc Automation and Control Solutions Honeywell Security & Communications 2 Corporate Center Dr. Suite 100 Melville, NY 11747 1.800.467.5875 www.honeywell.com LJVPLEXBRJD February 2011 © 2011 Honeywell International Inc. A 51 4OMPS-1 /51 4OMPS-2 Manual Pull Stations .a. DEMCO COMMERCIAL SECUTY SOWY1ONS PRIMARY FEATURES ADA COMPLIANT KEY TEST OR ALLEN RESET KEYED TO ADEMCO CONTROLS STYLIZED HIGH TECH DESIGN ALUMINUM DIE CAST HOUSING TERMINAL BLOCK OR WIRE LEADS GOLD CONTACTS UL LISTED • GENERAL DESCRIPTION Ademno's manual fire alarm stations are designed to be non-code single action devices for use in UL listed fire alarm applications. The attractive die-cast alu- minum-alloy housing meets ADA pull requirements and has been tested at Underwriter's Laboratory. For ADA compliance, manual stations must be mount- ed less than 48" above the floor for front wheelchair access and less than 54" above the floor for side wheelchair access. A key reset feature on the 514OMPS-1 is designed for positive authorized resetting action. The key is designed to operate and match Ademco controls. The 51 4IJMPS-1 utilizes a terminal block for secure terminations. The 5I40MPS-2 is furnished with an Allen hex fitting and is equipped with wire leads. Two alarm deterrent break tubes are supplied with each manual station; one tube is visible from the front, and the spare is stored in a compartment within the unit- OPERATION Pulling the handle down causes the manual stations to latch in the down position and to close the normally open switch. The handle is restored manually by using the key to unlock the station and pivot the station for- ward for resetting the pull handle to its normal posi- tion. The crush tube is then inserted in the cavity and the station assembly is then locked in the normal upright position. U CONSTRUCTION The 5140MPS-1 and 5I4OMPS-2 manual stations are constructed of a durable die-cast aluminum-alloy and provide a neat and distinctive appearance. The housing is finished in red with white raised lettering and the "1- bar handle is white with raised red lettering for enhanced visibility. The units are adaptable to both sur- face and semi-flush mounting configurations. U MOUNTING SEMI-FLUSH MOUNT Most semi-flush mount installations can be attached to a standard single-gang switch box using two 6-32 screws inserted through the slots that are centered on the unit's metal mounting plate. SURFACE MOUNT Use Ademco Backbox model number 5I4OMPS-BB for surface mount installations. The Backbox has four pre- drilled mounting holes of 0.187 inch diameter and con- duit knockouts. Secure the Backbox to a wall with screws of size 8 or smaller. After the Backbox is in place, attach the conduit. The housing is locked by using a key or Allen wrench lock. Unlock the housing by turning the key clockwise and swinging down the front of the housing to make the sheet metal mounting plate accessible. Mount the metal plate to the Backbox using the four 1/4" long, 8-32 screws (supplied). IN DIMENSIONS 4.75"Hx3.12"Wx2"0 0 ADEMCD The Technology Leader To previous device on control zone terminals To previous device or control zone terminals PULL 1 Wire Leads To next device - or ELOR PULL Screw Terminals To next device orL0P ORDERING INFORMATION 5I40MPS-1: Manual Station Key Reset Test and Terminal Block 5I40MPS-2: Manual Station Hex Allen Reset Test and Wire Leads 5I40MPS-BB: Surface Backbox WIRING DIAGRAM 514OMPS-1 5140MPS-2 ARCHITECTURAL/ENGINEERING SPECIFICATIONS Manual Fire Alarm Station Model 514OMPS41 mum distance of one huridmd feet, front or side. [514OMPS-21 shall be non-coded and include a break- Manual Stations Bhali be constructed of die cast type tube operated test-reset lock allowing testing aluminum alloy with clearly visible operating instruc- with a key (Allen wrench). They shall be designed so tions provided on the cover. The word FIRE shall that normal operation cannot be restored after an appear on the front of the stations in raised letters. actual Fire Emergency Operation except by use of a Stations shall ha suitable for surface mounting on key (Allen wrench). The key shall fit all standard matching Backbox,, or semi-flush mounting an a Ademco controls, standard single-gang box. Manual Stations shall be An operated station shall automatically condition itself Underwriters Laboratories Listed. so as to be visually detected, as operated, at a DEMCD L/MPS-i -2/OS The Technology Leader ( SYSTEM $ SENSOR Photoelectric Smoke Detectors System Sensor's /3 series smoke detectors represent significant advancement in conventional detection. The i3 family is founded on three principles: installation ease, intelligence, and instant inspection. Features Plug-in detector line, mounting base included Large wire entry port In-line terminals with SEMS screws Mounts to octagonal and single-gang backboxes, 4-square backboxes, or direct to ceiling Stop-Drop 'N Lock attachment to base Removable detector cover and chamber Built-in remote maintenance signaling Drift compensation and smoothing algorithms Simplified sensitivity measurement Wide angle, dual color LED indication Loop testing via EZ Walk feature Built-in test switch Agency Listings ® MEA MSFM LISTED APPROVED approved approved 0911 3011445 /2/2-1209:210 290-01-E 2093 Installation ease. The il line redefines installation ease with its plug-in design. This allows an installer to pre-wire the bases included with the heads. The large wire entry port and in-line terminals provide ample room for neatly routing the wiring inside the base. The base accommodates a variety of back box mounting methods, as well as direct mounting with drywall anchors. To complete the installation, il heads plug in to the base with a simple Stop-Drop 'N Lock' action. Intelligence. il detectors offer a number of intelligent features to simplify testing and maintenance. Drift compensation and smoothing algorithms are standard with the j3 line to minimize nuisance alarms. Two-wire il detectors needing cleaning can generate a remote maintenance signal, when connected to the 2W-MOD2 loop test/maintenance module, or to a panel equipped with the j3 protocol. This signal is indicated by LEDs located at the module and the panel. The SENS-RDR, a wireless device, displays the sensitivityof P detectors in terms of percent per-foot-obscuration. Instant inspection. The P series provides wide-angle red and green LED indicators for instant inspection of the detector's condition: normal standby, out-of-sensitivity, alarm, or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the P protocol, the EZ Walk loop test feature is available on two-wire i3 detectors. This feature verifies the initiating loop wiring by providing LED status indication at each detector. Ch Smoke Detector Specifications Smoke detector shall be a System Sensor P Series model number listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems. The detector shall be a photoelectric type (Model 2W-B, 4W-B) or a combination photoelectric/thermal (Model 2WT-B, 4WT-B) with thermal sensor rated at 135°F (57.2°C). The detector shall include a mounting base for mounting to 31/2-inch and 4-inch octagonal, single gang, and 4-inch square back boxes with a plaster ring, or direct mount to the ceiling using drywall anchors. Wiring connections shall be made by means of SEMS screws. The detector shall allow pre-wiring of the base and the head shall be a plug-in type. The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the UL smoke box. The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms. The detector shall provide dual color LED indication which blinks to indicate power up, normal standby, out of sensitivity, alarm, and freeze trouble (Model 2WT-B, 4WT-B) conditions. When used in conjunction with the 2W-MQD2 module, 2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel, and shall provide a loop testing capability to verify the circuit without testing each detector individually. Operating Voltage Nominal; 12/24V non-polarized Minimum; 8.5V Maximum: 35V Maximum Ripple Voltage 30% peak to peak of applied voltage Standby Current 2-wire; 50 pA maximum average; 4-wire: 50 pA maximum average Maximum Alarm Current 2-wire; 130 mA limited by control panel; 4-wire: 20 mA @12V, 23mA @ 24V Peak Standby Current 2-wire; 100 pA; 4-wire; n/a Alarm Contact Ratings 2-wire; n/a; 4-wire; 0.5 A @ 30V AC/DC ~'Physical Specifications Dimensions (including base) 5.3 inches (127 mm) diameter; 2.0 inches (51 mm) height Weight 6.3 01 (178 grams) Operating Temperature Range 2W-B and 4W-B; 32°F—i 20°F (0°C-49°C); 2WT-13 and 4WT-B; 32°F—i 00°F (0°C-37.8°C) Operating Humidity Range 0 to 95% RH non-condensing Thermal Sensor 135°F (57.2°C) fixed Freeze Trouble 2WT-B and 4WT-13 only; 41°F (5°C) Sensitivity 2.50/o/ft. nominal InputTerminals 14-22 AWG Mounting 31/2-inch octagonal back box 4-inch octagonal back box Single gang back box 4-inch square back box with a plaster ring Direct mount to ceiling LED ModesPower Uli Sequence Itfor LED Indication LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal (standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Ordering Information 2W-13 No 2-wire 130 mA max, limited by control panel 2WT-B Yes 2-wire 130 mA max. limited by control panel 4W-13 No 4-wire 20 mA % 12V, 23mA @ 24V 4WT-B Yes 4-wire 20 mA @ 12V, 23mA @ 24V Accessories 2W-MOD2 2-wire loop test / maintenance module RT Removal / replacement tool SENS-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket, 6.6 in. (16.76cm) diameter 2006 Syr— 5e,n, SYSTEM 1 3825 Ohio Avenue. St. Charles, IL 60174 1~1 SEIJSOR Phone; 800-SENSOR2. Fax; 630-377-6495 current product information, including the blest ersion of this dam shce.t Prepared by: c1' OF ENOINEERIF4O A SAFE & SECURE FUTURE TODAY Q Section 1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL 0 FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-1645:0123 Page 1 of 2 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: HONEYWELL SECURITY2 Corporate Center Or, Ste. 100, Melville, NY 11747 Contact: Issa Khouryawad (516) 577-2312 Fax (516) 577-3540 Email: issa.khouryawad@honeywell.com DESIGN: Models FA1 600C, FA1 670C, FA1 700C, Vista-1 00, Vista-1 28FB, Vista-1 28FBP, Vista-250FBP, and Vista-32FB fire alarm control units. Power-limited. Automatic, manual, noncoded, local, remote station, central station, waterflow and sprinkler supervisory service. Refer to listee's data sheet for additional detailed product description and operational considerations. Minimum system components: Vista 100, Vista-i 28FB, -32FB; Control Unit 1451 Transformer 6137, 6137-R, 6139, 6139-R Keypad *COMUL Enclosure *6160CR2 Alpha Keypad (for use with Vista series) *FA570CR Alpha Keypad (for use with First Alert series) *ECP Isolator *4146 Keyswitch *5140 DLM Backup Dialer Module *7845iENT Internet Communicator *4208U 8 Zone Remote Zone Expander *42085NF 8 Zone V-Plex Class A Adapter *Vplex VSI Short Isolator *4204CF Supervised *41905N 2 Zone Expansion Module *4193 Serial Number Interlace Module *4297 Polling Loop Extender *588iENHC, 5883-H Short Range RF Receiver RATING: Primary 120 VAC, 18 VAC Secondary, 12 VDC Standby INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as fire alarm control units for use with separately listed compatible initiating and indicating devices. This control unit can generate the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. Refer to Rev. 01-07-11 BH This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct SV operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division Listing No. 7165-1645:0123 Page 2 of 2 manufacturer's Installation Manual for details. This control unit meets the requirements of UL Standard 864, 9th Edition. NOTE: 1. For Fire Alarm Verification, the maximum Retard/Reset/Restart period shall not exceed 30.0 seconds. Burglary and other non-fire functions were not examined. Formerly 7165-0078:174 Changed company name and number to 2011 and Honeywell Security. 9-08-10. FM *Rev. 01-07-11 BH This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL _____ FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1645:0199 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: HONEYWELL SECURITY2 Corporate Center Dr, Ste. 100, Melville, NY 11747 Contact: Issa Khouryawad (516) 577-2312 Fax (516) 577-3540 Email: issa.khouryawad@Honeywell.com DESIGN: Models iPGSM-COM, iPGSM-DP, iPGSM-4G and *IGSMCFP4G Internet and Digital Cellular Fire Communicators. Units are suitable for residential and commercial applications. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as a control unit accessory for use with separately listed compatible commercial and residential fire alarm control units. *Model IGSMCFP4G is intended for use with specific Honeywell Security control units that employ the ECP bus. Refer to listee's installation Instruction Manual for details. NOTE: Burglary and other non-fire functions were not examined. iPGSM-COM, iPGSM-DP formerly listed in 7300-1645:0183. *Rev 07-01-14 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct VG operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division 11 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM - LISTING SERVICE LISTING No. 7150-1645:0118 S Page 1 of 1 CATEGORY: 7150-- FIRE ALARM PULL BOXES LISTEE: HONEYWELL SECURITY2 Corporate Center Dr, Ste. 100, Melville, NY 11747 Contact: Issa Khouryawad (516) 577-2312 Fax (516) 577-3540 Email: issa.khouryawad@honeywell.com DESIGN: Models 514OMPS-1 (Key lock) and 5I4OMPS-2 (Hex Lock) noncoded manual pull stations. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as manual pull stations for use with separately listed and compatible fire alarm control units. For indoor use only. Model 514OMPS-BB may be installed with all units. * This manual pull boxes meet the requirements of UL Standard 38, 1999 Edition with California amendments. NOTE: Formerly 7150-0078:169 XLF: 7150-1408:0107 10-28-2010 JC This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-1653:0152 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.linhart@systemsensor.com DESIGN: Models 2W-13, 2WT-B, 4W-B and 4WT-B photoelectric type smoke detectors. Models 2W-B and 2Wr-B are 2-wire and model 4W-B and 4WT-B are 4-wire detectors. Models 2W1-B and 4W1-B employ a thermistor type heat sensor (135°F). The heat sensor is are supplemental to the detector and is not intended for use as a required heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 8.5-35 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. For vertical wall or ceiling mount. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. Suitable for installation in open areas with air velocity range from 0-1000 ft/mm. NOTE: Formerly 7272-1209:210 06-20-05 TI This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division -\ tc3c2- Copyright 2013 National Fire Protection Association (NFPA). Licensed, by agreement, for individual use and single download via NFCSS All Access on January 29,2013 to KAYLEEN SMART for designated user t(afleo? SmarL'4o other reproduction or transmission in any form permitted without written permission of NFPA. For inquires or to report unauthorized use, contact licensing@nfpa.org. This NFCSS All Access subscription expires on 04/3012013. i DOCUMENTATION t I (iiI -' 72-37 SYSTEM RECORD OF COMPLETION This form is to be completed by the system installation contractor at the time of system acceptance and approval. It shall be permitted to modify this form as needed to provide a more complete and/or clear record. Insert N/A in all unused lines. Attach additional sheets, data, or calculations as necessary to provide a complete rord. Form Completion Date: 0 FC t / Supplemental Pages Attached:__________ 1. PROPERTY INFORMATION Name of property: 5 'I Address:___o 419 ___________ Description of property: Name of property representative: - Address: Phone: Fax: i9'1 E-mail: INSTALLATION, SERVICE, TESTING, AND MONITORING INFORMATION Installation contractor: _l4,r 4tf -41 Phone: Y'DfW' Fax:_________________ E-mail: Service organization: Address: Phone: __________________________ Fax:___________________________ E-mail: Testing organization: Address: Phone: _________________________ Fax:___________________________ E-mail: Effective date for test and in,ection contract: Monitoring organization: ?d4r Address: Phone: _________________________ Fax:___________________________ E-mail: Account number: ______________________ Phone line 1: Phone line 2: Means of transmission: Entity to which alarms are retransmitted: Phone: DOCUMENTATION On-site location of the required record documents and site-specific software: DESCRIPTION OF SYSTEM OR SERVICE This is a: ....New system Q Modification to existing system Permit number: NFPA 72 edition: 4.1 Control Unit Model number: 4.2 Software and Firmware Firmware revision number: - 4.3 Alarm Verification .his A system does not incorporate alarm verification. Number of devices subject to alarm verification: Alarm verification set for ________ seconds © 2012 National Fire Protection Association NFPA 72 (p.1 of 3) FIGURE 7.8.2(a) System Record of Completion. (SIG-FUN) 2013 Edition Cop)qight2013 aational Fire Protection Association (NFPA). Licensed, by agreement for individual use and single download via NFCSSAII Access on January 29, 2013 to KAYLEEN SMART for designated user Knyloan Smart No other reproduction or transmission in any form permitted without written permission of NFPA. For inquires or to report unauthorized use, contact Iiceneing@nfps.org. This NFCSS All Access subscription expires on 04130/2013. 72-38 NATIONAL FIRE ALARM AND SIGNALING CODE SYSTEM RECORD OF COMPLETION (continued) SYSTEM POWER 5.1 Control Unit 5.1.1 Primary Power Input voltage of control panel:/7# V1(' Control panel amps: 3 Overcurrent protection: Type: Amps:___________________ Branch circuit disconnecting means location: 442 1Z_ Number:___________________ 5.1.2 Secondary Power Type of secondary power: Al f)1p/y Location, if remote from the plant: Calculated capacity of secondary power to drive the system: In standby mode (hours): In alarm mode (minutes): 5.2 Control Unit system does not have power extender panels Power extender panels are listed on supplementary sheet A CIRCUITS AND PATHWAYS Dual Media Separate Survivability Pathway Type Pathway Pathway Class Level Signaling Line Device Power Initiating Device Notification Appliance Other (specify): REMOTE ANNUNCIATORS Type Location INITIATING DEVICES Addressable or Alarm or Sensing Type Quantity Conventional Supervisory Technology Manual Pull Stations Smoke Detectors Duct Smoke Detectors Heat Detectors Gas Detectors Waterfiow Switches Tamper Switches © 2012 National Fire Protection Association . NFPA 72 (p.2 of 3) FIGURE 7.8.2(a) Continued no wg 2013 Edition Copyright 2013 National Fire Protection Association (NFPA). Licensed, by agreement, for individual use and single download via NFCSS All Access on January 29. 2013 to KAYLEEN SMART for designated user Kayleen Smart No other reproduction or transmission in any form permitted without written permission of NFPA. For inquires or to report unauthorized use, contact licensing@nfpa.org. This NFCSS All Access subscription expires on 04/30/2013. DOCUMENTATION 72-39 SYSTEM RECORD OF COMPLETION (continued) NOTIFICATION APPLIANCES Type I Quantity I Description Audible Visible I Combination Audible and Visible SYSTEM CONTROL FUNCTIONS Type Quantity Hold-Open Door Releasing Devices HVAC Shutdown Fire/Smoke Dampers Door Unlocking Elevator Recall Elevator Shunt Trip INTERCONNECTED SYSTEMS .his system does not have interconnected systems. Interconnected systems are listed on supplementary sheet CERTIFICATION AND APPROVALS 12.1 System Installation Contractor This system as specified herein has been installed according to all NFPA standards cited herein. Signed: Printed name: Cy4/.1 Date: Organization: Title:_ Phone:________ 12.2 System Operational Test This system as specified herein has tested according to all NFPA standards cited herein. ___ Printed name. C4~ Date: Signed:4 7C Title:__ Phone:??Y"Z Organization:..T 12.3 Acceptance Test Date and time of acceptance test: Installing contractor representative:J (cy2e7 Testing contractor representative:00 Property representative:_ AHJ representative: © 2012 National Fire Protection Association NFPA 72 (p.3 of 3) FIGURE 78.2(a) Continued ML 2013 Edition