Loading...
HomeMy WebLinkAboutPRE 2023-0058; FAIRFIELD APARTMENT HOMES AT BRESSI; Admin Decision LetterNovember 27, 2023 Shon Finch Fairfield Gateway Road LLC 5355 Mia Sorrento Place San Diego, CA 92121 (cityof Carlsbad BFILE COPY SUBJECT: PRE 2023-0058 (DEV2022-0186) -FAIRFIELD APARTMENT HOMES AT BRESSI APN: 213-263-19-00, 213-263-20-00 Thank you for submitting a preliminary review application to construct a 74'-2"-tall, 320-unit, residential apartment building in Planning Area 5 of the Bressi Ranch Master Plan, MP 178(K). A total of 580 parking spaces are proposed within a six-level, at-grade parking garage. The project site, an approximately 5.33- acre site comprised of two legal lots (Lots 11 and 12 of CT 05-09), is located on the southwest corner of Palomar Airport Road and Gateway Road and east of El Fuerte Street. Primary access to the building is proposed mid-block, along the eastern segment of Gateway Road. Secondary access to the parking garage is proposed off the southern segment of Gateway Road. The site is currently pad-graded with the exception of a small detention basin located adjacent to Gateway Road on the south side of the lot. Street improvements include curb, gutter, sidewalk, street trees, and groundcover along Gateway Road. In response to your application, the Planning Division has prepared this comment letter. Please note that the purpose of a preliminary review is to provide you with direction and comments on the overall concept of your project. This preliminary review does not represent an in-depth analysis of your project. It is intended to give you feedback on critical issues based upon the information provided in your submittal. This review is based upon the plans, policies, and standards in effect as of the date of this review. Please be aware that at the time of a formal application submittal, new plans, policies, and standards may be in effect and additional issues of concern may be raised through a more specific and detailed review. Planning: 1. The current General Plan and zoning designations for the properties are as follows: a. General Plan: Planned Industrial (Pl); b. Zoning: Planned Community {P-C) -(Zoned Planned Industrial {P-M) within the Bressi Ranch Master Plan); and c. Bressi Ranch Master Plan, MP 178K. 2. The project is site is identified as Potential Housing Site No. 11 ("Bressi Ranch Gateway Road Industrial Parcels") in the city's Housing Element. The site is currently being studied as part of an Environmental Impact Report (EIR) to change the General Plan and Zoning land use designations on a number of properties to comply with the state's Regional Housing Needs Assessment (RHNA). Specifically, the city is studying a proposal to change the General Plan Land Use designation at the subject site from Planned Industrial {Pl) to Residential, 37.5 to 40 dwelling units per acre (R-40). Community Development Department Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008 I 442-339-2600 PRE 2023-0058 (DEV2022-0186) -FAIRFIELD APARTMENT HOMES AT BRESSI November 27, 2023 Pa e 2 Under the current General Plan Land Use designation, no residential units can be constructed. Draft EIR 2022-0007 was considered by the Planning Commission on October 18, 2023 and received a recommendation of approval. The project is tentatively scheduled for consideration by the City Council in January 2024. If the land use change from Pl to R-40 is approved by the City Council, a total of 214 units could be constructed on the 5.33-acre site. The preliminary review analysis contained within this letter and reflected in the submittal assumes the land use change will be approved. 3. Housing developments that contain a minimum of 20 percent affordability to lower-income (i.e. low and very low) households as required pursuant to Government Code section 65583(c)(l) and 65583.2(h) and that are on specific sites rezoned by the City Council to meet RHNA requirements as detailed in the programs of the Housing Element shall be permitted "by right" as that term is defined in Government Code Section 65583.2(h) and shall be subject to the mitigation measures of Supplemental Environmental Impact Report EIR 2022-0007. Please note, staff is still researching what, if any, permits beyond a building permit will be required for the proposed project. Listed below are the potential permits that could be required. In addition, as stated above, in order for the proposed project to be considered "by right", a minimum of 20% or 64 units shall be affordable to lower-income households. At this time, it is not clear how many inclusionary housing units are proposed. a. Site Development Plan b. Master Plan Amendment. The rezoning program includes an amendment to the Master Plan MP 178(K) to address the increase in the number of units associated with the rezone. An evaluation of the Master Plan with the proposed project will be needed to determine if there are other changes that need to occur. Please see page 703 of the link below for the draft changes proposed to MP 178(K): https://www.carlsbadca.gov/home/showpublisheddocument/15265/638331283137070 000 c. · A lot Line adjustment to merge the properties will be required prior to issuance of the grading permit. The lot merger requires the approval of the City Engineer. 4. As part of the Housing Plan Update, the city is proposing changes to the Residential Density- Multiple (RD-M) Zone. Please see link below for a draft of the changes. Please note the analysis provided in the subject preliminary review is based on the proposed development standards. If the changes proposed to the RD-M zone are not approved and the project is required (or proposes) to rely on the existing RD-M standards, the required setbacks and building height may change. https://www.carlsbadca.gov/home/showpublisheddocument/14356/638249361476281335 5. Density/Density Bonus. If the proposal to change the General Plan Land Use designation from Pl to R-40 is approved, the following is a summary of the calculation for the base number of units that could be permitted within the density range of 37.5 to 40 dwelling units per acre: PRE 2023-0058 {DEV2022-0186) -FAIRFIELD APARTMENT HOMES AT BRESSI November 27, 2023 Pa e 3 Base Unit Range for 5.33-acre parcel in R-40 Zone: 200-214 dwelling units: Minimum density= 37.5 du/ac: 37.5 x 5.33 = 199.8; rounds up to 200 dwelling units Maximum density= 40 du/ac: 40 x 5.33 = 213.12; rounds up to 214 dwelling units Density Bonus (DB) The project proposes 320 units and includes a request for a 50% density bonus {213 base units x 1.5 = 319.5 or 320 units). Density Bonus Incentives/Concessions and Waivers. Pursuant to State Density Bonus Law, the number of incentives and concessions that can be requested by a developer varies by the amount and type of reserved affordable housing units being proposed. Please see the table below for some examples of how many incentives could be granted based on the level and percentage of affordability. Income % of Reserved Units Very Low 5% 10% 15% 80%ormore Low 10% 17% 24% 80%ormore Moderate 10% 20% 30% 20%maximum Senior** n/a n/a n/a n/a Incentives 1 2 3 4* •To qualify for 4 lncentlves, a project must reserve at least 80% of the units for lower Income households {very low, low, er combination thereof). The remaining 20% may be reserved for moderate income households. *" Senior projects with no affordable hol.lSlng are not entitled to Incentives. As part of the request for incentives or concessions, the city requires applicants to provide reasonable documentation to show that any requested incentive will result in identifiable and actual cost reductions to provide for affordable housing costs or rents {CMC 21.86.050A.5). The city must grant a requested incentive or concession unless it finds the following: a. The concession or incentive does not result in identifiable and actual cost reductions to provide for affordable housing costs or rents. b. Granting the concession or incentive would have a specific adverse impact on public health or safety or on property listed on the California historical register, which cannot be mitigated, or would be contrary to state or federal law In addition, waivers or a reduction of a development standards may be granted if a developer provides reasonable documentation showing that the City's standards would physically preclude the allowed densities and incentives. Please refer to the link below for the city's State Density Bonus Law Informational Bulletin, 18- 112: https://www.carlsbadca.gov/home/showpublisheddocument/8169/637744794162930000 PRE 2023-0058 (DEV2022-0186) -FAIRFIELD APARTMENT HOMES AT BRESSI November 27, 2023 Pa e 4 Please refer to the link below for the Density Bonus Supplemental Checklist, P-l(H): https:ljwww.carlsbadca.gov/home/showpublisheddocument/450/637843404170270000 6. lnclusionary Housing. Pursuant to the proposed amendments to the Bressi Ranch Master Plan, any residential development (rental or for-sale) shall enter into an affordable housing agreement with the City of Carlsbad to provide a minimum of 20% of the total housing units on the site of the residential development as affordable to lower income (i.e., low and very low) households at 80% or below the San Diego County Area Median Income. This affordable housing requirement may also be satisfied by the following alternatives (at the sole discretion of the City of Carlsbad and following completion of an alternate public benefit analysis): 7. • At least 15% of the total housing units shall be affordable to low-income households and an additional 10% shall be affordable to moderate-income households; or • At least 15% of the total housing units shall be affordable to very low-income households. Please specify how you intend to satisfy the affordable housing requirements with the next submittal. An affordable housing agreement shall be approved prior to issuance of the first building permit. Draft City-Wide Objective Design Standards (ODS). The proposed project is subject to the city- wide ODS. Please see link below for reference and revise the project design as appropriate. Please note, if the project does not comply with more than 4 of new standards, additional density bonus incentive, concessions or waivers will need to be requested. On the next submittal, please highlight in the project plans and correspondence (please reference sheet numbers) how the project complies with the standards and complete the ODS checklist. Please ensure the building elevations and floor plans are dimensioned in 40' intervals. City-wide ODS: https://www.carlsbadca.gov/home/showpublisheddocument/13768/63820l047511900000 City-wide ODS checklist: https://www.carlsbadca.gov/home/showpublisheddocument/15323/638332233693100000 Objective Design Standards Processing Guide: https://www.carlsbadca.gov/home/showpublisheddocument/15321/638331501903600000 Listed below are some of the requirements in which the project may not comply. Please note, this list is not all-inclusive. Please include a detailed analysis of the project's compliance with the ODS with the project submittal. a. Section 2-Passenger Pickup and Drop-off Location. Projects with 50 or more units shall provide at least one pick-up and drop-off location located within 100 feet of a common recreational space (such as a community clubhouse or pool), or located within 100 feet of a vehicular access point. The passenger loading space shall be at least the size of a standard parking space and shall be clearly marked and visible from an entry driveway PRE 2023-0058 (DEV2022-0186) -FAIRFIELD APARTMENT HOMES AT BRESSI November 27, 2023 Pa e 5 (access point) into the site. Pick-up and drop-off locations shall incorporate a minimum of one bench and one shade structure. It is noted the passenger pick-up drop off area will be located in the parking structure. Where is it located? Will the structure be gated? If so, how will the public be able to access? b. Section 2-Private Open Space. For any deck or balcony provided, the minimum dimension shall be 6' wide x 6' deep. Screening shall be constructed with limited openings to provide a minimum of 85 percent surface area screening (measured from the finished floor of the private recreational space to the top of the railing, fencing, or walls). The metal railing details do not appear to comply with 85% screening. Please revise. c. Section 2 -Landscaping. d. Landscape Buffer. A landscape buffer a minimum of five feet shall be located adjacent to all ground-level residential spaces to provide additional privacy and security for residents. The buffer shall be planted with dense evergreen shrubs which grow to or are maintained at a maximum height of four feet. Please submit exhibits demonstrating compliance. Not enough information is provided. A note is included on the plans but compliance is not shown on the landscape plan. Pedestrian Walkways. Pedestrian walkways shall be flanked on both sides with landscaping, including, groundcover, and shrubs a maximum of four feet in height. A tree shall be provided on either side of the walkway at a minimum of every 50 feet of walkway length. Regular alternating intervals of trees on both sides of all walkways may be provided where there is sufficient space to promote healthy tree growth and avoid root damage to adjacent hardscape elements. Please submit detailed exhibits demonstrating compliance. Section 3-Building Form and Massing. Building Form and Hierarchy. Buildings greater than two stories shall be designed to differentiate a defined base; a middle or body; and a top, cornice, or parapet cap. Buildings two stories or less shall include a defined base and top. The "base" and "top" each shall not exceed two stories in height. This effect shall be achieved through at least two of the following for all buildings: a. Color, texture, or material changes. **Please revise the plans to carry the enhanced material around the entire base per the example in the ODS. b. Variations, projections, or reveals in the wall plane. c. Variations in fenestration size or pattern. d. Decorative architectural details such as cornices and columns, or arcades. Wall Plane Variation. Building fac;ades visible from the primary street shall not extend horizontally more than 40 feet in length without a two-foot variation in depth in the wall plane. Building entrances, unit entrances, upper-story setbacks, and projections such as stoops, porches, bays, overhangs, fireplaces, and trellises count towards this requirement. PRE 2023-0058 (DEV2022-0186) -FAIRFIELD APARTMENT HOMES AT BRESSI November 27, 2023 Pa e 6 e. a. Upper Floor Area Reduction. The floor area for upper floors shall be a maximum of 90% of the ground floor area. The upper floor area shall not protrude over the first floor along the street frontage more than five feet. Staff understands a waiver from this requirement will be requested. b. Horizontal Articulation. Walls visible from a public right-of-way shall not run in a continuous horizontal plane for more than 40 feet without incorporating articulating features such as glazing, overhangs, cornices, canopies, columns, pilasters, trellises, arches, or clearly defined projecting or recessed architectural elements. Please show how the project complies. Corner Buildings. Corner buildings greater than two stories shall include one or more of the following features on both facades. Please indicate which criteria the project complies with and where it is shown in the plans. The plans should include details to assist staff with verifying compliance. a. An entry to ground-floor commercial uses or a primary building entrance located within 25 feet of the corner of the building. b. A different material application, color, or fenestration pattern of windows and doors from the rest of the fa~ade located within 40 feet of the corner of the building. c. A change in height of at least 5 feet (taller or shorter) compared to the height of the abutting fa~ade, located within 40 feet of the corner of the building. Roofline Variation. Roof lines shall not extend horizontally more than 40 feet in length without at least one prominent change as described below. Which one does the project comply with? How and where in the plans can this be verified? Please specifically call out on plans. a. Provide variation in roof form, such as hipped, gable, shed, flat, and mansard. b. Provide variation in architectural elements, such as parapets, varying cornices, chimneys, and reveals. c. Provide variation of roof height of at least 18 inches (as measured from the highest point of each roof line). Flat Roofs and Parapets. Parapets shall be provided around the perimeter of a flat roof. a. Rooftop equipment shall be located a minimum of five feet away from any roof edge and parapet adjacent to a public right-of-way. b. Interior side of parapet walls shall not be visible from a common recreational space or public right-of-way. c. Parapets shall be capped with precast treatment, continuous banding, projecting cornices, dentils, or similar edge treatment. Building and Unit Entrances. Entrances for buildings and individual units shall incorporate architectural treatments e.g., feature window details, towers, decorative veneer or siding, porches, stoops) and/or PRE 2023-0058 (DEV2022-0186)-FAIRFIELD APARTMENT HOMES AT BRESSI November 27, 2023 Pa e 7 8. changes in roof line or wall planes. Common building entrances shall include weather protection that is a minimum 6 feet wide and 4 feet deep by recessing the entrance, or providing an awning or similar weather protection element. Common building entrances shall provide a minimum of 40 square feet of decorative and accent paving that contrast in color and texture from the adjacent pedestrian walkway paving. f. Windows and Doors. Please revise the plans to confirm compliance. Details should be added to the plans. Window Treatment. Windows shall either be recessed at least two inches from the plane of the surrounding exterior wall, or shall have a trim or windowsill at least two and a half inches in depth. a. Windows Facing a Public Street or Common Recreational Spaces. Windows within 40 feet of public right-of-way or common recreational spaces shall feature enhanced window treatments, such as decorative lintels, trim, shutters, awnings, and/or trellises. Setbacks. Pursuant to the amendments proposed to the Bressi Ranch Master Plan, the RD-M setbacks will apply to the proposed development. The required setbacks are as follows: Front (north property line-Palomar Airport Road): 20 feet; can be reduced to 10 feet if fully landscaped; as designed, the project complies. Front (south property line-Gateway Road): 20 feet; can be reduced to 10 feet if fully landscaped; as designed the project complies. Street Side (east property line-Gateway Road): 10 feet; as designed, the project complies. Side (west property line): 5 feet; as designed, the project complies. 9. Parking. The project description and plans submitted with the application indicate 1.5 parking spaces per unit or a total of 580 spaces will be provided. Pursuant to MP 178(K), the parking shall comply with Chapter 21.44, Parking Ordinance, of the Carlsbad Municipal Code. As a density bonus is proposed, current density bonus law supersedes the Parking Ordinance. Per state density bonus law, no more than one parking space can be required for studios and one-bedroom units and no more than 1.5 spaces can be required two or three-bedroom units. The project plans provide the following breakdown for the types of units: Unit type: Studio units: none One-bedroom units: 180 Two-bedroom units: 111 Three-bedroom units: 29 Parking required: 180 x 1 space per unit = 180 spaces 111 x 1.5 spaces per unit= 167 spaces 29 x 1.5 spaces per unit= 43.5 or 44 spaces TOTAL SPACES REQUIRED= 391 PRE 2023-0058 (DEV2022-0186)-FAIRFIELD APARTMENT HOMES AT BRESSI November 27, 2023 Pa e 8 10. A total of 391 parking spaces are required and a total of 580 are proposed. Therefore, the preliminary design currently complies with the minimum number of parking spaces required per current density bonus law. A detailed parking analysis will be completed once the application is submitted. Parking dimension in a parking structure. Pursuant to CMC Section 21.44.060, Table D, the minimum dimension for parking stalls in a parking garage are 8.5 feet x 20 feet, exclusive of supporting columns/posts. In addition, a back-up distance of 24 feet and 5-foot turning bump- out is required at the end of a stall series (i.e., dead end). Please also ensure an area is striped for "No Parking" to allow room for cars to pull-into and safely back-up and turn-around. With the project submittal, please demonstrate compliance with these standards. Building Height. Pursuant to the proposed amendments to CMC Section 21.24.030 (RD-M, Building Height), on sites with an R-40 land use designation, no building shall exceed a height of 45 feet. Please note, the proposed restrooms and enclosed fitness center on the roof, preliminarily proposed at a height of approximately 74'-2" feet, are not allowable architectural projections. Therefore, the structures are required to be included/considered as part of the overall building height. To reduce building height and limit the visual impacts, staff strongly recommends removal of these features on the roof. Further, since the proposed building height exceeds 45 feet, an incentive/concession or waiver will need to be requested as part of the density bonus request. In addition, please provide details on the pool equipment room and restroom with the next submittal. The design shall complement the architecture of the multi-family building. 11. McClellan-Palomar Airport Land Use Compatibility Plan (ALUCP) -The project site is located on Lots 38 and 39 of the Bressi Ranch Master Plan, which is located within the McClellan-Palomar Airport Influence Area (AIA). New development within the AIA must be reviewed for consistency with an adopted land use compatibility plan for the airport. The Bressi Ranch Master Plan was approved under the Comprehensive Land Use Plan (CLUP) for McClellan-Palomar Airport, which was originally adopted on April 22, 1994 and later amended on October 4, 2004. A new document has since been approved by the San Diego Airport Land Use Commission (ALUC). Renamed as the McClellan-Palomar Airport Land Use Compatibility Plan (ALUCP), this document was adopted on January 25, 2010 and later amended on March 4, 2010 and December 1, 2011. The proposed land use change is significantly different than the land use approved under the prior compatibility plan. As a result, the project will be subject to review and consistency findings of the new ALUCP (see ALUCP Policy 2.3.2(c)). Please be advised the ALUC has reviewed the proposed changes to the General Plan Land Use designation as part of the -EIR process that is currently underway for the potential new housing locations. Please see attached letter from the ALUC for reference. If a determination of consistency is made as part of the current EIR process, ALUC review may not be required for the proposed project. Preliminary review of this project against the new ALUCP revealed the following: PRE 2023-0058 (DEV2022-0186) -FAIRFIELD APARTMENT HOMES AT BRESSI November 27, 2023 Pa e 9 a. Exhibit 111-1-Compatibility Policy Map: Noise. The project site is located outside of the 60 db CNEL noise exposure range per Exhibit 111-1. Pursuant to the ALUCP Section 3.3.3(a) on page 3-19: "The threshold for evaluation is the projected 60 dB CNEL contour. This contour defines the noise impact area of the Airport. All land uses located outside of this noise contour are consistent with the noise compatibility policies." b. Exhibit 111-2-Compatibility Policy Map: Safety. The project site is located entirely within Safety Zone 6 (Traffic Pattern Zone) per Exhibit 111-2. Pursuant to Table 111-2 (Pgs. 3-45 through 3-52), Residential, >20.0 du/ac is considered compatible within Safety Zone 6 with no F.A.R. restrictions. However, the project proposes some small communal/assembly-type areas (i.e., communal terraces, pool area, game room, community room, lounge, fitness area, etc.), that would all need to be further analyzed within a formal submittal after additional information has been provided regarding the sizes of each and their maximum accommodations. c. Exhibit 111-3 -Compatibility Policy Map: Part 77 Airspace Protection. The project site is located within the 7:1 Transitional Surface contour of Exhibit 111-3. Formal submittal of this project under the ALUCP would require compliance with the Federal Aviation Administration's (FAA) Federal Aviation Regulations (FAR) Part 77, Objects Affecting Navigable Airspace. FAR Part 77 regulations require that anyone proposing to construct an object, which could affect navigable airspace around an airport, submit information about the proposed construction to the FAA. Because the proposed building height exceeds what is currently being studied in the Draft EIR for the Housing Plan Update and what is allowed in the RD-M zone and the Bressi Ranch Master Plan, an FAA Part 77 may still be required. A final determination will be made once the application is submitted. d. Exhibit 111-4 -Compatibility Policy Map: Overflight. The project site is located within the Overflight Notification Area. Pursuant to the ALUCP Policy 3.6 -Overflight Compatibility Policies for McClellan-Palomar Airport, real estate disclosures and overflight notification documents would need to be recorded. e. Exhibit 111-5 -Compatibility Policy Map: Airport Influence Area. The project site is located within Review Area #1 of the Airport Influence Area. Review Area #1 consists of locations where noise and/or safety concerns may necessitate limitations on the types of land use actions. Please see discussions above in subsection a) and b). f. Exhibit 111-6 -Compatibility Policy Map: Avigation Easement Area and Overflight Notification Areas. The project site is located outside of the Avigation Easement Area, but is located within the Airport Overflight Notification Area. As noted above in subsection d) above, real estate disclosures and overflight notification documents would need to be recorded. Please see link below for the McClellan-Palomar Airport Land Use Compatibility Plan: https:ljwww .ca rlsbadca .gov /home/showpubl ished docu ment/226/637 4466177 57230000 12. Architecture/Massing. PRE 2023-0058 (DEV2022-0186) -FAIRFIELD APARTMENT HOMES AT BRESSI November 27, 2023 Pa e 10 a. The architectural design of the building shall comply with the minimum residential design standards of MP 178(K). The architectural design guidelines can be found in Section X of MP 178(K). b. Significant upgrades are recommended to the west elevation, which lacks building articulation. The northern one-third of the elevation faces the light industrial business park to the west and will be highly visible to east-bound traffic on Palomar Airport Road. Please consider revising the floor plan on this side of the building to relocate the hallway, similar to what is proposed on the east side of the building. Additional articulation is needed on this side of the building and relocating the hallway may address this concern. Other design changes can also be considered to further articulate the west elevation. Please make sure tall growing trees are a part of plant palette in this area. The ODS also require additional articulation in this area. Waivers may need to be requested if the project does not comply. c. Please add a large plant green screen to the west elevation of the parking garage to further articulate this elevation. Please revise the landscape plan, elevations and site plan to address this comment. The response notes Italian Cypress are proposed along the west elevation. I do not see this tree in the palette. Please confirm with landscape architect. The overall goal is to provide tall evergreen trees along this elevation. All necessary application forms, submittal requirements, and fee information are available at the Planning counter located in the Faraday Building at 1635 Faraday Avenue or online at www.carlsbadca.gov. You may also access the General Plan Land Use Element and the Zoning Ordinance online at the website address shown; select Department Listing; select Planning Home Page. Please review all information carefully before submitting. Land Development Engineering: 1. On civil plan or site plan, include ADT and peak hour trips per generation rates from SAN DAG Brief Guide of Vehicular Traffic Generation Rates for the San Diego Region on the site plan/tentative map. 2. If a Local Mobility Analysis is required by the City's Traffic Division, refer to the Transportation Impact Analysis Guidelines at: https://www.carlsbadca.gov/home/showpublisheddocument/328/637425982502330000. 3. Depending on the CEQA determination, which is determined after the application for discretionary permits is submitted and assuming such permits are required, a Vehicle Miles Traveled (VMT) analysis may be required per the Vehicles Miles Traveled Analysis Guidelines available at https:ljwww.carlsbadca.gov/home/showdocument?id=312. 4. Based on the completed E-34 form this project is a Priority Development Project (PDP) and a complete Storm Water Quality Management Plan (SWQMP) is required. The 'Preliminary Storm Water Basis for Design' report dated October 2023 and submitted with this application correctly concludes that the property is subject to hydromodification and that critical course sediment yield areas (CCSYA) are mapped on the property per the Watershed Management Area Analysis (WMAA). As noted in the report, a complete evaluation will be included in the SWQMP to PRE 2023-0058 (DEV2022-0186)-FAIRFIELD APARTMENT HOMES AT BRESSI November 27, 2023 Pa e 11 determine if the project is exempt from further analysis of CCSYA. Also, incorporate trash capture measures on the project plans and into the storm water quality management plan to be prepared per form e-35. The post construction stormwater treatment BMPs shall be shown on a conceptual grading plan and drainage plan with the discretionary application or on the construction grading plans if no discretionary application is required. 5. Provide a Preliminary Title Report (current within the last six (6) months). 6. Annotate and delineate all existing easements and encumbrances listed in the Preliminary Title Report on the site plan. If any vacations or quitclaims are planned with this development annotate on the site/civil plan. The private drainage easement appearing on Map 14960 shall be vacated. Consult the HOA and SDG&E for encroachments proposed within their respective landscape and utility easements appearing on the property. 7. A Preliminary Hydrology Study including map and calculations is required to demonstrate capacity/sizing of proposed and existing storm drain infrastructure. Show 100-year storm hydrologic calculations before and after development for each drainage basin. Per the 'Preliminary Storm Water Basis for Design' report dated October 2023 and submitted with this application the proposed vault at the southwest corner of the property will be used to reduce the increased post-development runoff of the QlOO storm to pre-development levels in addition to hydromodification measures for the 85th percentile storm. Provide vault model and details and include all invert elevation, flow line elevations, weir elevations and orifice sizes to demonstrate proper flow and retention. 8. A preliminary geotechnical report is required to evaluate the feasibility of the project. Guidelines for preliminary geotechnical studies are available on the City of Carlsbad Engineering website. 9. Per CMC15.16.060 this project will require a grading permit and grading plan. 10. NGVD 29 datum for vertical control was used and is the proper datum to use. 11. Plot direction of roof drainage flow on the DMA exhibit and civil plan. 12. An adjustment plat with a certificate of compliance will be required for the lot consolidation. Alternatively, a subdivision map may be processed in lieu of an adjustment plat. 13. Show location and dimensions of all accessways and pathways as required for compliance with Title 24-State Accessibility Requirements. 14. If the project is planning to connect a storm drain to the sanitary sewer for emergency and incidental flows in the covered parking garage, the developer shall apply for a provisional source control permit with Encinas Wastewater District. 15. Be aware that, as stated in the previous preliminary review PRE2023-0036, a sewer study and water study will be required with your discretionary applications, or if discretionary applications are not required, with the grading plan check. PRE 2023-0058 (DEV2022-0186) -FAIRFIELD APARTMENT HOMES AT BRESSI November 27, 2023 Pa e 12 16. Address the comments on the attached redlined plan. 17. Please be advised that a more in-depth review of the proposed development will occur with the discretionary permit application or grading plan check application when a more complete design of the project is provided. Utilities: **Since a water and sewer study were not submitted for review, the subject preliminary review was not routed to Utilities for additional review/comment. Therefore, the comments from the previous preliminary review, PRE 2023-0036, are included below for reference. If no discretionary permits are required, the studies shall be submitted for review as part of the grading permit submittal. 1. Prior Utilities comment to submit a water study under PRE2022-0051 is noted in responses as in process and will be submitted with next submittal. It is noted that a zoning change is being processed for this project, which will require CMWD modeling the development impacts to the existing water system at the developer's expense and may trigger off-site water improvements as a condition of approval. 2. Prior Utilities comment to submit a sewer study under PRE2022-0051 is noted in responses as in process and is expected to be submitted with next submittal. It is noted that a zoning change is being processed for this project, which will require Carlsbad modeling the development impacts to the existing sewer and pump station at the developer's expense and may trigger off-site sewer improvements as a condition of approval. 3. Revise and update Civil Site Plan indicating utility connection locations with meter and backflow sizes based on approved water and fire flow demands. All connections to the public utilities shall be detailed on plans in accordance with current city engineering standards. a. Approved Fire Department flow requirements shall be used to determine the size(s) and number of potable water utility connections that are required for fire protection and sprinkler system. b. Irrigation connection(s) shall require a separate meter and backflow. Note: It is advised that Landscape Plans not be submitted for approval prior to finalizing civil site plans as any subsequent modifications would trigger resubmittal. Traffic Division: 1. Please coordinate with Nick Gorman, nick.gorman@carlsbadca.gov, to submit a Scoping Agreement per the latest City of Carlsbad Transportation Impact Analysis Guidelines. Landscaping: PRE 2023-0058 (DEV2022-0186) -FAIRFIELD APARTMENT HOMES AT BRESSI November 27, 2023 Pa e 13 Numbers below are referenced on the red line plans where appropriate for ease in locating the area of the comment concern. 1. During the Pre-Concept review there was a question whether recycled irrigation water may be used within the fenced pool area. CMWD has reviewed this question and stated that recycled water is acceptable as long as there is no overspray. For the proposed drip system in the pool area, recycled water is acceptable. 2. There is one symbol that appears to be for an existing tree near the corner of Palomar Airport Road and Gateway. Please identify what this tree is and whether it is to remain or be removed. 3. On the Slope Planting Notes (sheet L.7), for Standard 3, please revise 2-3/4" liners to 1-gallon containers. 4. Eight Pepper Trees are shown along Palomar Airport Road. They are shown outside of the Right of Way. Please verify with Parks Department during this Concept Plan phase, the actual location of the trees. If they are included in the City Street Tree Inventory (per Parks and Recreation Department), then they should be relocated inside the Right of Way. Please verify and adjust locations as appropriate. 5. Please coordinate with the civil engineer to show and identify the CalTrans Sight Stopping Distance Lines at street and driveway intersections as are shown on the civil plans. As with the sight triangles, no visual obstructions greater than 30" will be allowed within the CalTrans sight lines. 6. Please add a note to the plan to specify that any trees located within a vehicular sight line must have all limbs removed to a height of 6 feet above the adjacent top of curb. 7. Four existing City Street Trees are identified to be removed. Please submit plans to the City Parks Department and determine through the Parks Department if these trees are designated as City Street Trees. Please provide a memo from the Parks Division indicating their determination regarding the trees (approved for removal, protect in place, remove and replace, etc.) Depending on the determination by the Parks Division, the applicant may need to complete an application for removal and have it approved by the City. The applicant should contact the Parks Department to request preliminary approval but should advise the Parks Division to refrain from drafting or posting a bulletin until 30 days prior to anticipated site demolition. 8. Please provide a colored or hatched plan clearly showing where recycled water, graywater and potable water are proposed to be used for irrigation. It is noted that the general site will be irrigated with recycled water, Please include the swimming pool/spa as potable water. This plan will be forwarded to Carlsbad Municipal Water District (CMWD) for review. Any comments will be returned to the applicant. 9. Please provide a callout label to identify each and every BMP feature with associated planting and irrigation. Please include the "Biofiltration Raised Planter Boxes" identified on the civil grading plan. It is not clear if these are currently shown on the landscape plan. PRE 2023-0058 (DEV2022-0186) -FAIRFIELD APARTMENT HOMES AT BRESSI November 27, 2023 Pa e 14 10. On the Shrub Planting Legend, please revise the WUCOLS IV water use categories for the plants noted in the legend. 11. PLEASE RETURN REDLINES and provide 2 copies of all plans (concept, water conservation, and colored water use plan) for the next submittal. The submittal must be made to a Planning Division staff member at the Planning counter along with a transmittal clearly indicating what the submittal is for {i.e. Conceptual Plan re-submittal). Please provide a written response to all comments clearly indicating where and how each comment was addressed. 1. Fire access has been approved through an Alternative Means and Method (AM&M) submittal. If you would like to schedule a meeting to discuss this letter with the commenting departments, please contact Shannon Harker at the number below. You may also contact each department individually as follows: • Planning Division: Shannon Harker, Senior Planner, at (442) 339-2621 • Land Development Engineering: David Rick, Project Engineer, at (442) 339-2781 • Public Works, Traffic: Nick Gorman, at (442) 339-2793 • Public Works, Utilities: Markus Mohrle, at (442) 339-2322 Sincerely, ERIC LARDY City Planner EL:SH:ES Enc: Airport Land Use Commission Consistency Determination letter dated November 13, 2023 Landscape red lines Engineering red lines c: Eric Lardy, City Planner Cliff Jones, Principal Planner David Rick, Project Engineer Markus Mohrle, Utilities Nick Gorman, Traffic Laserfiche/Data Entry Case File November 13, 2023 Mr. Scott Donnell City of Carlsbad 1635 Faraday Avenue Carlsbad, California 92008 Re: Airport Land Use Commission Consistency Determination -General Plan Amendments to Housing and Public Safety Elements with Rezones, City of Carlsbad Dear Mr. Donnell: As the Airport Land Use Commission (ALU() for San Diego county, the San Diego County Regional Airport Authority (SDCRAA) acknowledges receipt of an application for a determination of consistency for the project described above. The area covered by this project lies within the Airport Influence Area (AIA) for the McClellan-Palomar Airport -Airport Land Use Compatibility Plan (ALUCP). ALUC staff has reviewed your application and accompanying materials and has determined that it meets our requirements for completeness. In accordance with SDCRAA Policy 8.30 and applicable provisions of the State Aeronautics Act (Cal. Pub. Util. Code §21670-21679.5), ALUC staff will report to the ALUC that the proposed project is conditionally consistent with the McClellan-Palomar Airport ALUCP based upon the facts and findings summarized below: (1) The proposed project involves amendments to the Carlsbad General Plan Housing and Public Safety Elements and rezoning of 18 sites (12 within the AIA) to designations allowing residential uses or increased residential densities. One of the rezone sites (Site 9) was previously reviewed and found to be conditionally consistent by a prior ALUC consistency determination in 2020. The proposed General Plan amendments are to implement the rezones, to reflect current disaster mitigation and planning practices, and to implement state law. No actual development is proposed under the current project, but future development may be subject to ALUCP compatibility factors as detailed below. PO Box 82776 San Diego, CA 92138-2776 www.san.org/aluc AIRPORT LAND USE COMMISSION SAN DIEGO COUNTY REGIONAL AIRPORT AUTHORITY ' •' .• . }~ . .• -~ ~-~!t• , (2) Four-of the re.?one sit~s (Sites 6, 8, 9, and 16) of the proposed project are located within the 60-65 decibel Community Noise Equivalent Level (dB CNEL) noise contour. The ALUCP identifies residential uses located within the 60-65 dB CNEL noise contour as conditionally compatible with airport uses, provided that the residences are sound attenuated to 45 dB CNEL interior noise level. Therefore, as a condition of project approval, future residential development under the proposed project which is located within the 60-65 dB CNEL noise contour must be sound attenuated to 45 dB CNEL interior noise level. (3) The proposed project does not involve any actual construction, but all sites of future development under the project would be subject to the applicable airspace protection standards of the ALUCP. The ALUCP identifies proposed construction as compatible with airport uses, provided that a determination of no hazard to air navigation has been issued for the proposed construction on the site by the Federal Aviation Administration (FAA) or the project sponsor has certified that notice of construction is not required to the FAA because the construction is located within an urbanized area, is substantially shielded by existing structures or natural terrain, and cannot reasonably have an adverse effect on air navigation. Additionally, the ALUCP requires that an avigation easement for airspace protection be recorded in favor of the airport operator with the County Recorder for any construction on sites in which the existing grade penetrates FAA airspace protection surfaces. Site 10 of the project application lies within the terrain penetration area requiring recordation of an avigation easement. Therefore, as a condition of project approval, all future construction under the proposed project must obtain a determination of no hazard to air navigation from the FAA ·or be certified by the project sponsor as not requiring notice of construction to the FAA. Additionally, all construction within terrain penetration areas identified by the ALUCP as requiring an avigation easement, such as on Site 10, must record the avigation easement with the County Recorder. (4) Seven of the rezone sites (Sites 4 and 6 through 11 inclusive) of the proposed project are located within safety zones. All seven sites lie at least partially within Safety Zone 6, and the ALUCP identifies residential uses located within AIRPORT LAND USE COMMISSION Safety Zone 6 as compatible with airport uses. A portion of Site 1 0 is located within Safety Zone 2, and the ALUCP identifies residential uses located within Safety Zone 2 as not compatible with airport uses. Therefore, as a condition of project approval, future residential development under the proposed project may not be permitted within Safety Zone 2 unless the proposed development is permitted in accordance with the applicable overrule procedures as defined in the aforesaid State Aeronautics Act. (5) The proposed project does not involve any actual development, but sites of future residential development may be subject to overflight notification requirements. The ALUCP requires that a means of overflight notification be provided for new residential land uses located within the overflight notification area. Therefore, as a condition of project approval, a means of overflight notification must be provided for each residential unit located within the overflight notification area. In instances when an avigation easement is required, such as for Site 10, the overflight notification requirement is satisfied. (6) Therefore, if the proposed project contains the above-required conditions, the proposed project would be consistent with the McClellan-Palomar ALUCP. (7) A determination of consistency is not a "project" as defined by the California Environmental Quality Act (CEQA), Cal. Pub. Res. Code §21065, and is not a "development" as defined by the California Coastal Act, Cal. Pub. Res. Code §30106. The information above will be reported to the ALUC to confirm this letter at its public meeting on December 7, 2023. The determination of consistency will be final as of that meeting, unless the ALUC finds cause to delay such action, in which case a determination will be rendered within 60 days of the date of this letter, to be confirmed by additional correspondence. Any determination rendered by the ALUC is limited to the project plans and descriptions submitted with the application and is not transferable to any AIRPORT LAND USE COMMISSION .SAN DIEGO COUNTY REGIONAL IFfPORT AUTHORITY revision of this or any similar, future project involving a change in land use, in building or crane height, or in building area in excess of 10 percent (provided area increase does exceed ALUCP standards) of any prior ALUC determination. Any change or exceedance in these characteristics requires a new consistency determination prior to decision-making consideration by the local agency. Please contact Ed Gowens at (619) 400-2244 or egowens@san.org if you have any questions regarding this letter. Yours truly, /'i; (/ Ralph Redman Manager, Airport Planning cc: Amy Gonzalez, SDCRAA General Counsel Sjohnna Knack, SDCRAA Planning and Environmental Affairs Jamie Abbott, County of San Diego Airports AIRPORT LAND USE COMMISSION