HomeMy WebLinkAboutPRE 2023-0053; SUNNY CREEK; Admin Decision LetterDecember 12, 2023
Robert Davis
Sunny Creek Development Partners LP
6405 Mira Mesa Boulevard
San Diego, CA 92121
SUBJECT: PRE 2023-0053 (DEV2022-0213} -SUNNY CREEK
APN: 206-090-11-00
Ccicyof
Carlsbad
8FILE COPY
Thank you for submitting a preliminary review for the construction of 416 residential units on a 17.6-acre
site located on the northwest corner of El Camino Real and College Boulevard. Specifically, a total of 166
townhomes (126 attached and 40 detached) are proposed on a 9.6-acre site and 250 apartments are
proposed on an 8.09-acre site. The proposed densities are 17.29 and 30.9 dwelling units per acre,
respectively.
Common amenities at the apartment site include a club house, leasing office, and a pool/spa. A total of
29 or 17% of the 166 town homes are proposed as affordable housing units. The site is currently developed
with a 20,000-square-foot recreational vehicle storage area for the Terraces of Sunny Creek residential
development located on the east side of College Boulevard. The RV storage area is proposed to be
relocated to the northeast corner of the property to accommodate the access driveway off College
Boulevard.
In response to your application, the Planning Division has prepared this comment letter. Please note that
the purpose of a preliminary review is to provide you with direction and comments on the overall concept
of your project. This preliminary review does not represent an in-depth analysis of your project. It is
intended to give you feedback on critical issues based upon the information provided in your submittal.
This review is based upon the plans. policies, and standards in effect as of the date of this review. Please
be aware that at the time of a formal application submittal. new plans, policies, and standards may be
in effect and additional issues of concern may be raised through a more specific and detailed review~
Planning:
1. General Plan and zoning designations for the property are as follows:
a. General Plan: Residential 8-15 du/ac/Local Shopping Center (R-15/L);
b. Zoning: Residential Density Multiple/Local Shopping Center (RD-M/C-L); and
c. The property is located in Area 3 of the El Camino Real Scenic Corridor and Development Area
4 of Local Facilities Management Plan 15(E).
2. A Draft Environmental Impact Report EIR 2022-0007 to change the General Plan and Zoning land
use designations for a number of properties in the city to comply with the state's Regional Housing
Needs Assessment (RHNA) was considered by the Planning Commission on October 18, 2023 and
Community Development Department
Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008 I 442-339-2600
PRE 2023-0053 (DEV2022-0213) -SUNNY CREEK
December 12, 2023
Page 2
received a recommendation of approval. The project is tentatively scheduled for consideration by
the City Council in January 2024. The project site is one of three parcels identified as Potential
)' t Housing Sif~l'fo.,4 or the "Zone 15 Cluster" in Appendix C in the city's Housing Element. Specifically,
'the city is SttJd:ying a proposal to change the General Plan Land Use designation at the subject site
(APN 209-060-11) from R-15/L to R-15/R-30. Under the current General Plan Land Use designation,
a total of 110 residential units can be constructed, If the land use change from R-15 to R-30 is
approved by the City Council, a total of 322 units could be constructed on the 17.6-acre site, The
preliminary review analysis contained within this letter and reflected in the submittal assumes the
land use change will be approved.
3, Housing developments that contain a minimum of 20 percent affordability to lower-income
households as required pursuant to Government Code section 65583(c)(1) and 65583.2(h) and that
are on specific sites rezoned by the City Council to meet RHNA requirements as detailed in the
programs of the Housing Element shall be permitted "by right" as that term is defined in
Government Code Section 65583.2(h) and shall be subject to the mitigation measures of
Supplemental Environmental Impact Report EIR 2022-0007. Please note, staff is still researching and
working with the City Attorney's office on what, if any, permits beyond a building permit will be
required for the proposed project. Listed below are the potential permits that could be required.
4.
a, Tentative Tract Map (CT) for the development of 166 air-space condominiums and to create a
separate lot for the eight acre apartment site;
b. Planned Development Permit (PD) for the development 166 attached and detached airspace
condominiums;
c. Site Development Plan (SDP) for the development of 250 apartments;
d. Special Use Permit (SUP) for development in the floodplain;
e. Special Use Permit for development adjacent to the El Camino Real scenic corridor;
f. Nonconforming Construction Permit for the relocation of the recreational vehicle storage
area, Please ensure the appropriate parties are informed of the proposal to relocate the RV
storage area.
Density/Density Bonus. The detailed calculations for each residential site below are based on a total
site area of 17,6 acres. Please note, Planning staff has determined the area of the RV storage lot
shall be included in the overall density calculation, This area was not excluded in the city's Housing
Element update as it was assumed the entire property will be developed with residential units, If
the RV storage area will remain, the area of the lot shall be included in one of the residential
project's density calculations,
a. R-15, 9.6-acre parcel
Pursuant to the Key Site Fact Sheet for Potential Housing Site No. 4, a total of 115 units are
projected at 12 du/ac, which is the proposed minimum density for the R-15 General Plan Land
Use designation. At the maximum density, 15 du/ac, 144 units could be constructed on the
9.6-acre site. Based on the proposal to construct 166 condominium units, the proposed
density calculation for the site is as follows:
166 units+ 9.6 acres= 17,29 du/ac
PRE 2023-0053 (DEV2022-0213) -SUNNY CREEK
December 12, 2023
Page 3
Therefore, the proposal to construct 166 units exceeds the maximum allowable density of 15
du/ac and a density bonus will be required.
b. R-30, 8-acre parcel
Pursuant to the Key Site Fact Sheet for Potential Housing Site No. 4, a total of 212 units are
projected at 26.5 du/ac, which is the proposed minimum density for the R-30 designation. At
the maximum density, 30 du/ac, 242 units could be constructed on the 9.6-acre site Based on
the proposal to construct 250 apartments, the proposed density calculation for the site is as
follows:
250 units+ 8.09 acres= 30.9 du/ac
Therefore, the proposal to construct 250 apartment units exceeds the maximum density of 30
du/ac and a density bonus will be required.
5. lnclusionary Housing. Pursuant to Planning Commission Resolution No. 7114 (see attached for
reference), a minimum of 20 percent of the total residential housing units for the R-15 and R-30
parcels are required to be designated as affordable to lower income households at 80% or below
the San Diego County Area Median Income. At the sole discretion of the City of Carlsbad and
following completion of an alternate public benefit analysis, the residential development (rental or
for-sale) may be permitted to produce affordable housing units on the site of the residential
development that meet one of the following minimum requirements as an alternative to satisfy the
lower income affordable housing requirement set forth above.
1. A minimum of 15 percent of the total projects housing units shall be affordable to lower
income households at 80% or below the San Diego County Area Median Income and an
additional 10 percent shall be affordable to moderate income households at 100% or
below of the San Diego County Area Median Income; or
2. A minimum of 15 percent of the total project housing units shall be affordable to very
low-income households at 50% or below the San Diego County Area Median Income.
As currently proposed, it does not appear any inclusionary units are proposed at the apartment site.
Further, the townhome site does not meet the minimum 20 percent requirement (17 percent
proposed). Please ensure each development provides the minimum 20 percent of the total number
of units.
In addition, if the unit count is increased such that a density bonus is requested, per CMC Section
21.86.030 of the city's Density Bonus Ordinance and CMC Section 21.85.050 of lnclusionary Housing
Ordinance:
All housing development projects are subject to Chapter 21.85-lnclusionary Housing, including
projects that also qualify for a density bonus under this chapter. The affordable housing
requirements of the two chapters are not cumulative. If an applicant seeks to construct affordable
housing to qualify for a density bonus in accordance with the provisions of this chapter, those
affordable dwelling units provided to meet the inclusionary requirement established pursuant to
Chapter 21.85 of this title shall also be counted toward satisfying the density bonus requirements
PRE 2023-0053 (DEV2022-0213) -SUNNY CREEK
December 12, 2023
Page 4
6.
of this chapter. For projects that qualify for a density bonus, the inclusionary housing requirement
shall be based on the total residential units approved for the project, including any density bonus
dwelling units awarded pursuant to this chapter.
Density Bonus-Waivers/Concessions. Correspondence submitted with the application indicates
waivers will be requested for an increase in building height within the El Camino Real Corridor
setback area and a reduction in width for the one-car garages. Please see link below for Application
P-l(H) for the information required to be submitted for the requested waivers.
https://www .ca rlsbadca .gov /home/showpublisheddocume nt/ 450/637708551460670000
7. The Housing Crisis Act of 2019 (SB 330) established a preliminary streamline application process for
housing projects. It is not mandatory unless applicants seek the vesting and processing benefits
offered under SB 330. Participation in the SB 330 streamline process would occur first, followed by
the formal development application process required under Government Code (Gov. Code) §§
65940, 65941, 65941.5, and Carlsbad Municipal Code (CMC) § 21.42.050. Acceptance by the city of
a complete SB 330 Streamline Application (Form P-32) and fee will vest the project for 180 days in
accordance with the ordinances, policies and standards in effect at the time the SB 330 Application
is accepted.
8. Climate Action Plan (CAP). New requirements related to the city's goals to reduce greenhouse gas
(GHG) emissions will likely impact development requirements of this project. A formal application
submittal will need to include a completed CAP Checklist (Form P-30} to determine what
requirements will apply to the project. New GHG reduction requirements are related to energy
efficiency, photovoltaic, electric vehicle charging, water heating and traffic demand management
requirements, as set forth in the California Green Building Standards Code and in CMC Chapters
18.21, 18.30 and 18.51 which is available on the city's website at the following address:
9.
http://www.gcode.us/codes/carlsbad/view.php?topic=18&frames=on
To the extent that new GHG reduction requirements are in effect at the time of application for
grading or building permits, the project will be required to comply with the effective requirements
even if different than what is proposed in the project's planning approvals. GHG reduction
requirements may impact, but are not limited to, site design and local building code
requirements. If incorporating new GHG reduction requirements results in substantial
modifications to the project after planning approvals are obtained, then prior to issuance of grading
or building permits, the applicant may be required to submit and receive approval of a Consistency
Determination or an Amendment application for the project through the Planning Division.
Noise Analysis. As the subject parcel is adjacent to El Camino Real and College Boulevard, please
submit a noise analysis analyzing the project's consistency with the General Plan and Noise
Guidelines Manual. The Noise Guidelines Manual can be found online at:
https://www.carlsbadca.gov/home/ showpublisheddocument/23 8/ 63 7 4 25 97 40923 70000
PRE 2023-0053 (DEV2022-0213) -SUNNY CREEK
December 12, 2023
Page 5
10. Biological Resources Assessment. Please submit a biological resources technical report from a
registered biologist indicating the type and area of habitat located on the property, as well as the
proposed impacts. Please ensure the BRTR complies with the following guidelines:
https:/ /www.carlsbadca.gov/home/ showpublisheddocument/1604/63 7819050500430000
11. Cultural Resources Assessment. As the project is located in an area of known cultural sensitivity,
please submit a cultural resources assessment prepared by a qualified professional. The study shall
comply with the city's Tribal, Cultural and Paleontological Resources Guidelines. Please be advised
the Guidelines require a Luiseno Native American monitor to be present for any field survey or work
conducted by an archaeologist. Please see the link below for additional information.
https://www.carlsbadca.gov/home/showpublisheddocument/254/63 7 425976516870000
12. Fair Share Contribution for the Construction of College Boulevard. Pursuant to Local Facilities
Management Plan (LFMP) 15(E), prior to recording a final map or the issuance of a grading permit
or building permit (whichever comes first), the applicant shall enter into a secured financial
agreement in a form acceptable to the City Council that will secure its fair share of the cost of
constructing the extension of College Boulevard between the northern boundary of Development
Area 4 to Cannon Road.
13. El Camino Real Scenic Corridor Standards. The parcel is located within Area 3 of the El Camino Real
Corridor Standards. The area of the property which is subject to the standards is dependent on the
topography of the site. More specifically, the standards would apply to the following areas noted
below. Detailed topographical information will need to be provided to support the determination
as to which standards will apply as it will also impact the required height and setbacks. In addition,
please be advised that these standards will be applied to the future property line after the right-of-
way is dedicated for the deceleration lane.
Area of applicability:
a. 300 feet deep for upslope area (5' higher than street grade); or
b. 400 feet deep for at-grade areas (within 5' of street level)
Building height:
a. Within 100 feet of El Camino Real (ECR) right-of-way (ROW): 15 feet, measured from pad
elevation;
b. Within 100-200 feet of ECR ROW: 25 feet, measured from pad elevation; and
c. Within 200-300 feet of ECR ROW: 35 feet, measured form pad elevation.
Required setbacks off El Camino Real for residential uses:
a. Upslope: minimum 45' from ROW or minimum of 15' from the top of the slope, whichever is
greater;
b. At grade: minimum 60' from ROW; some method of screening shall be incorporated into the
design such as earthen berms, decorative walls, heavy landscaping or a combination thereof. In
no case shall a 6-foot-tall wall or parking area encroach closer than 25 feet of the ROW.
c. Driveways may be included in the setback, but parking may not.
PRE 2023-0053 (DEV2022-0213) -SUNNY CREEK
December 12, 2023
Page 6
14. RD-M Zone-Apartment Setbacks. Exclusive of setbacks off El Camino Real, the apartment project
is subject to the following setbacks:
Front: See setbacks from El Camino Real
Street Side (College Boulevard frontage): On any side of a lot which is adjacent to a street, the side
yard shall be ten feet, with exception that: the required ten-foot side yard abutting a street may be
reduced to five feet, providing parking spaces do not open directly onto the street and, that the side
yard is landscaped and maintained as prescribed in CMC Section 21.24.040
Side (property line shared with townhomes): 5 feet
Rear (property line opposite El Camino Real): 10 feet
15. RD-M Zone/Planned Development/Condominiums. Detached single-family dwellings and attached
townhomes designed as airspace condominiums require the approval of a Planned Development
Permit pursuant to CMC Chapter 21.45, Planned Development Ordinance. Specifically, the proposed
condominium project shall comply with Table C, General Development Standards, and Table E,
Condominium Projects. Please see comments below for a Planned Development compliance
analysis and staff recommendations.
Planned Development Ordinance. Pursuant to CMC Chapter 21.45, Tables C and E, please be aware
of the following requirements. Please be advised the comments are not all-inclusive. Please. refer to
CMC Chapter 21.45 to ensure the project complies.
Table C, General Development Standards
a. Major arterial setback. College Boulevard: 40 feet; half of the width shall be landscaped. A
10' setback is proposed off College Boulevard. Therefore, the project does not comply. Please
redesign the project to comply. Please consider attaching the detached units so an increased
landscaped setback can be provided.
b. Private streets. The proposed private streets shall have a minimum ROW width of 56 feet and
a minimum curb-to-curb width of 34 feet, with parking on one side. As designed, the project
proposes a 26-foot-wide drive aisle width and does not comply. As part of the 56-foot ROW
width, there shall be a minimum 5.5'-wide parkway (curb adjacent) and a 5-foot-wide
sidewalk (both sides). Street trees are required to be spaced 30 feet on-center within the
parkway. Please redesign the private streets so the parkway is adjacent to the drive aisle
instead of the sidewalk.
c.
d.
e.
f.
Drive aisles. The minimum drive aisle width between the garages is 20 feet and the minimum
back-up space required between garages is 24 feet. As designed the project complies.
However, please ensure there is a five-foot deep kicker space at the end of each drive aisle
for vehicles back into when exiting the garage.
Visitor parking. 0.25 spaces per unit. As 166 units are proposed, 42 visitor spaces are
required. The project proposes 58 surface parking spaces and complies. Please ensure the
parking spaces are dimensioned so staff can verify compliance with the dimension standards.
Compact parking: Up to 25% of the visitor parking (or spaces) can be compact spaces. Please
confirm how many compact spaces are proposed. The minimum dimension for compact stalls
is 8 feet by 15 feet. No overhang is permitted into any required setback or sidewalks less than
6 feet in width.
Screening of parking. Open parking areas shall be screened from adjacent residences and
public ROW by either a wall or landscaping or combination thereof. Please ensure the
landscape plan submitted with the project addresses this requirement.
PRE 2023-0053 (DEV2022-0213) -SUNNY CREEK
December 12, 2023
Page 7
g. Community recreational space. 200 square feet per unit or a total of 28,600 square feet is
required. Community recreational space shall be provided as both passive and active
recreational facilities for a variety of age groups. A minimum of 75% of this area or 21,450
square feet shall be dedicated toward active uses such as a pool, tennis courts or a children's
playground. Please consider providing one, large central community recreation area. Please
provide additional details as to what is proposed in the community recreation area. While it
appears the project complies with the area requirements, the active uses are not shown;
therefore, compliance cannot be verified. In addition, it appears a portion of the townhome
project's community recreation area is located on the apartment site. Please clarify. This area
should be located on the townhome lot and included in the density calculation. The
apartment site should be a minimum of 8 acres, exclusive of this area.
h. Community recreation area parking. In addition to the required visitor and resident parking,
one parking space shall be provided for each 15 residential units, or fraction thereof, for units
located more than 1000 feet from the community recreation area. It's not clear where the
main community recreation area will be so the analysis cannot be competed at this time.
i. Recreational vehicle (RV) storage. RV storage is not required for projects located within the
R-15 or R-30 General Plan Land Use designations.
j. Storage space. 480 cubic feet per unit. If two-car garages are proposed with a minimum
dimension of 20' x 20', the requirement is satisfied. Please ensure the width and depth of the
garages are dimensioned and do not include the walls of the garage. As currently proposed,
it does not appear the project complies with this requirement. If the project does not comply,
a density bonus waiver will need to be requested.
Table E. Condominium Projects
a. Lot coverage. 60% of the developable acreage.
b. Building height. 35 feet, 3 stories. Please show building heights on all elevations as measured
from existing grade or finished grade, whichever is lower. If proposing to establish a new
grade pursuant to CMC Section 21.04.065, please add a note on the plans stating the request
and ensure the elevations show existing and proposed grade.
c. Setbacks.
• Private street. Residential structure~ 10 feet; direct entry garage 20 feet.
• Drive aisle. Residential structure -5 feet, fully landscaped; garage -3 feet
• Perimeter .. Same as underlying RD-M zone; minimum 5 feet for interior sides (north and
south property lines) and minimum 10 feet for rear (west property line). However, a
minimum 40' setback should be provided off College Boulevard. As designed, the project
does not comply.
d. Resident parking. Two covered spaces per unit; two-car garages shall have a minimum
dimension of 20' x 20'. Additional space outside of this area shall be included for trash
receptacles and a water heater.
e. Private recreational space. Please see Table E.8 in CMC Section 21.45.080 for additional
details.
• One-family dwellings: 200 square feet per unit; minimum dimension of 10 feet if provided
at-grade. If provided above ground level as deck or balcony, the minimum dimension is
6 feet and the minimum area is 60 square feet. Compliance cannot be verified.
• Multi-family dwellings: 60 square feet per unit; minimum dimension of 6 feet.
Compliance cannot be verified.
PRE 2023-0053 (DEV2022-0213)-SUNNY CREEK
December 12, 2023
Page 8
16.
• Please ensure the floor plans and site plan include dimensions for the
decks/balconies/porches.
Site Design. Planning staff has the following comments on the site design for the project:
a. Please consider relocating the community open space for the townhomes so it is more
central to the development and not adjacent to El Camino Real. It should be visible and
centrally located for all residents to enjoy. Please consider locating a drive aisle within this
area.
b. Please add a 5-foot-deep kicker/turning bump-out space at the end of each drive aisle so
cars backing out of the garage can back into this area.
c. A solid six-foot-tall decorative screen wall with a cap and pilasters, as well landscaping is
recommended in between the apartment and townhome communities.
d. Clarify whether the apartment community will be gated. If a gate is proposed and the Fire
Department requires secondary access for the town home community, the gate may need to
be eliminated.
17. VMT/CEQA Analysis. VMT is used to measure the transportation impact of projects that require
CEQA analysis. The location, access, density/building intensity, size and type of uses proposed will
all be evaluated for environmental impacts accordingly. If a project is found to have a significant
transportation VMT impact, it must identify feasible mitigation measures that could avoid or
substantially reduce an impact to less than significant. An analysis with supporting evidence must
demonstrate the effectiveness of the site design, project design features, and/or mitigation
measures at reducing significant transportation VMT impacts.
18.
During the course of environmental review for your project, if required, we would likely consider
the interaction between the proposed land uses and the internal/external road networks to
ensure that vehicle trip-inducing aspects of the project are not omitted in the VMT analysis. From
a CEQA perspective, if additional analysis is required, it is recommended the proposed internal
roadway improvements as implemented as part of the proposed project be redesigned to
improve circulation and accommodations for bicyclists and pedestrians. The potential for impacts
is highly dependent upon the circulation system, both within the vicinity, and within the project
itself.
Aside from the CEQA transportation VMT analysis, the city may require the preparation of a
circulation/operations analysis (Local Traffic Study) to forecast, analyze, and describe how a
development will affect existing and future circulation infrastructure for all users of the
transportation system, including vehicles, bicycles, pedestrians and transit. The
circulation/operations analysis assists making land use, infrastructure planning, and other
development recommendations and/or decisions. At this time, city staff is determining how best
to quantify the expected changes in transportation conditions, including future construction of
College, and evaluating the efficacy of potential improvements, exactions, and/or fair-share
contributions, if warranted.
Offsite Access. A portion of the secondary access driveway off El Camino Rea.I is located offsite.
While a recorded access easement currently exists which allows for the access, permission is
needed from the owner of APN 209-060-48-00 to construct the retaining wall on their property.
Please submit the authorization letter with the application.
PRE 2023-0053 (DEV2022-0213) -SUNNY CREEK
December 12, 2023
Page 9
19. City-Wide Objective Design Standards (ODS). The City Council recently adopted city-wide
objective design standards for multi-family residential projects (i.e., apartments and
condominiums). Please see link below for reference and revise the project design as appropriate.
https://www.carlsbadca.gov/home/showpublisheddocument/13 7 68/638312272425670000
Listed below are some of the requirements in which the project may not comply. Please note, this
list is not all-inclusive. Please include a detailed analysis ofthe project's compliance with the ODS
with the project submittal. Up to four waivers can be granted as part the ODS compliance analysis.
Any additional waivers needed will need to be requested as part of the density bonus.
a. Section 2-Site Design Standards
Common Open Space. The common open space area shall be adjacent to or visible from
the primary street.
Enhanced Paving for Entry Driveways. Entry driveways connecting public streets to the
interior of the site shall use enhanced paving treatment with patterned and/or colored
pavers, brick, or decorative colored and scored concrete, a minimum of 12 feet deep, and
spanning the width of the driveway.
Traffic Calming Measures. Projects with privately owned or maintained streets shall
implement four traffic calming measures and techniques from the City's Residential
Traffic Management Program (Phase II or Phase Ill) throughout the project. Examples of
such traffic calming tools include speed tables and speed cushions, high visibility
crosswalks, and intersection bulb-outs.
Vehicle Light Intrusion. Vehicle parking areas shall be located, oriented, and/or screened
to prevent visual intrusion of vehicle lights into habitable residential spaces. Where
parking areas are located within 15 feet of a residential unit, they shall be located within
a garage, carport, or parking structure, or screened by a solid wall, fence, or landscaping
a minimum of six feet in height.
Passenger Pickup and Drop-off Location. Projects with 50 or more units shall provide at
least one pick-up and drop-off location located within 100 feet of a common recreational
space (such as a community clubhouse or pool), or located within 100 feet of a vehicular
access point. The passenger loading space shall be at least the size of a standard parking
space and shall be clearly marked and visible from an entry driveway (access point) into
the site. Pick-up and drop-off locations shall incorporate a minimum of one bench and
one shade structure.
Private Open Space. For any deck or balcony provided, the minimum dimension shall be
6' wide x 6' deep. Screening shall be constructed with limited openings to provide a
minimum of 85 percent surface area screening (measured from the finished floor of the
private recreational space to the top of the railing, fencing, or walls).
PRE 2023-0053 (DEV2022-0213) -SUNNY CREEK
December 12, 2023
Page 10
La ndsca ping.
Landscape Buffer. A landscape buffer of minimum five feet shall be located adjacent to
all ground-level residential spaces to provide additional privacy and security for residents.
The buffer shall be planted with dense evergreen shrubs which grow to or are maintained
at a maximum height of four feet.
Pedestrian Walkways. Pedestrian walkways shall be flanked on both sides with
landscaping, including, groundcover, and shrubs a maximum of four feet in height. A tree
shall be provided on either side of the walkway at a minimum of every 50 feet of walkway
length. Regular alternating intervals of trees on both sides of all walkways may be
provided where there is sufficient space to promote healthy tree growth and avoid root
damage to adjacent hardscape elements.
Privacy. Landscape screening shall obscure direct sight lines into dwelling units and
private recreational space from communal areas such as parking areas, common
mailboxes, and pedestrian walkways. Landscaping may be used in combination with walls,
fencing, and/ or trellises to screen views where consistent with objective standards from
the Carlsbad Landscape Manual.
b. Section 3-Building Form and Massing.
Building Form and Hierarchy. Buildings greater than two stories shall be designed to
differentiate a defined base; a middle or body; and a top, cornice, or parapet cap.
Buildings two stories or less shall include a defined base and top. The "base" and "top"
each shall not exceed two stories in height. This effect shall be achieved through at least
two of the following for all buildings:
a. Color, texture, or material changes.
b. Variations, projections, or reveals in the wall plane.
c. Variations in fenestration size or pattern.
d. Decorative architectural details such as cornices and columns, or arcades.
Wall Plane Variation.
Building fa~ades visible from the primary street shall not extend horizontally more than
40 feet in length without a two-foot variation in depth in the wall plane. Building
entrances, unit entrances, upper-story setbacks, and projections such as stoops, porches,
bays, overhangs, fireplaces, and trellises count towards this requirement. a. Upper Floor
Area Reduction. The floor area for upper floors shall be a maximum of 90% of the ground
floor area. The upper floor area shall not protrude over the first floor along the street
frontage more than five feet. b. Horizontal Articulation. Walls visible from a public right-
of-way shall not run in a continuous horizontal plane for more than 40 feet without
incorporating articulating features such as glazing, overhangs, cornices, canopies,
columns, pilasters, trellises, arches, or clearly defined projecting or recessed architectural
elements.
Corner Buildings.
Corner buildings greater than two stories shall include one or more of the following
features on both facades:
PRE 2023-0053 (DEV2022-0213) -SUNNY CREEK
December 12, 2023
Page 11
a. An entry to ground-floor commercial uses or a primary building entrance located within
25 feet of the corner of the building.
b. A different material application, color, or fenestration pattern of windows and doors
from the rest of the fac;ade located within 40 feet of the corner of the building.
c. A change in height of at least 5 feet (taller or shorter) compared to the height of the
abutting fac;ade, located within 40 feet of the corner of the building.
Roofline Variation.
Roof lines shall not extend horizontally more than 40 feet in length without at least one
prominent change as described below:
a. Provide variation in roof form, such as hipped, gable, shed, flat, and mansard.
b. Provide variation in architectural elements, such as parapets, varying cornices,
chimneys, and reveals.
c. Provide variation of roof height of at least 18 inches (as measured from the highest
point of each roof line).
Flat Roofs and Parapets.
Parapets shall be provided around the perimeter of a flat roof.
a. Rooftop equipment shall be located a minimum of five feet away from any roof edge
and parapet adjacent to a public right-of-way.
b. Interior side of parapet walls shall not be visible from a common recreational space or
public right-of-way.
c. Parapets shall be capped with precast treatment, continuous banding, projecting
cornices, dentils, or similar edge treatment.
Garages.
Garage doors shall be recessed into the garage wall a minimum of four inches to
accentuate shadow patterns and relief. Garages shall not be located adjacent to the
primary street unless there is no other driveway access available onsite for residential
parking.
Building and Unit Entrances.
Entrances for buildings and individual units shall incorporate architectural treatments
e.g., feature window details, towers, decorative veneer or siding, porches, stoops) and/or
changes in roof line or wall planes.
Common building entrances shall include weather protection that is a minimum 6 feet
wide and 4 feet deep by recessing the entrance, or providing an awning or similar weather
protection element. Common building entrances shall provide a minimum of 40 square
feet of decorative and accent paving that contrast in color and texture from the adjacent
pedestrian walkway paving.
Individual Unit Entrance.
a. Ground-Floor Unit Entrance. Residential entrances located on the ground floor shall
include one or more of the following:
1. Entrance Types. Allowable unit entrance forms include: porch, stoop, patio, terrace,
forecourt, and courtyard.
PRE 2023-0053 (DEV2022-0213) -SUNNY CREEK
December 12, 2023
Page 12
20.
21.
2. Weather Protection. Entrances shall have either a projected sheltering element or be
recess.
Windows and Doors.
Window Treatment. Windows shall either be recessed at least two inches from the plane
of the surrounding exterior wall, or shall have a trim or windowsill at least two and a half
inches in depth. a. Windows Facing a Public Street or Common Recreational Spaces.
Windows within 40 feet of public right-of-way or common recreational spaces shall
feature enhanced window treatments, such as decorative lintels, trim, shutters, awnings,
and/or trellises.
Bus Turnout. The North County Transit District (NCTD) may require a bus turn-out pocket along
the El Camino Real frontage. Please begin coordination with NCTD to determine if it will be
required. Please be advised that if a bus turn-out is required, a bus shelter shall be included.
RV Storage Area. Staff has the following questions and comments regarding the RV storage area:
a. Please refer to links to Planning Commission No. 4294 and City Council staff report below for
background as it relates to the discussion.
Resolution:
https://records.carlsbadca.gov/Weblink/DocView.aspx?id=4830781&dbid=0&repo=CityofC
arlsbad&searchid=b02797dl-477b-44bd-b01c-43ee81722d9b
City Council staff report (includes Planning Commission staff report with details regarding RV
storage area-see pdf page 124):
https://records.carlsbadca.gov/Weblink/DocView.aspx?id=4860214&dbid=0&repo=CityofC
a rlsbad&sea rch id=d3fd08ba-a b 7f-4394-93a9-68c63b6fa 177
b. It has been determined that the RV storage area shall be included in the density calculation.
The update to the Housing Element assumes the entire lot will be developed with residential
units. Therefore, the areas is required to be included in the density calculation for either the
R-15 or R-30 designation. Please ensure that each site meets the minimum density.
c. An administrative Nonconforming Construction Permit (NCP) will be required for the RV
storage area as it will be considered a legal nonconforming use once the commercial
designation is changed to residential as part of the Housing Element Update process.
d. Please submit any copies of any agreements that exist on title related to the RV storage area.
Please confirm that a private agreement exists on title to address who is responsible for the
long-term maintenance of the RV storage lot. If it does not currently exist, an agreement
will be required prior to issuance of a grading permit for the proposed project. Pursuant to
research completed by Planning staff, including a review of the staff report for the Terraces
of Sunny Creek residential development (link included above), the current RV storage area
was originally intended to be a temporary location until a permanent location could be found
within Zone 15. Since Zone 15 has remained largely undeveloped, the RV storage area has
remained in its current location.
e. Pursuant to the staff report for the Terraces of Sunny Creek (see pdf page 124), a minimum
of 3,440 square of RV storage was required for the RV storage lot for the Terraces of Sunny
PRE 2023-0053 (DEV2022-0213) -SUNNY CREEK
December 12, 2023
Page 13
22.
23.
24.
Creek. Please confirm the size of the RV storage area complies with this standard and update
the plans to note the size.
f. Confirm how many RV spaces exist and ensure the project proposes to replace the same
number of spaces.
g. Dimension the proposed stalls to confirm an RV can be parked in each space.
h. A gate, screen wall and landscaping shall be proposed around the perimeter of the RV lot as
part of the proposed project. Please coordinate any changes with the appropriate
homeowner's association (HOA).
i. Provide contact information for the HOA for the RV storage lot.
j. With the next submittal, provide correspondence from the HOA indicating the group has
been consulted regarding the proposed change.
The Housing Crisis Act of 2019 (SB 330) established a preliminary streamline application process
for housing projects. It is not mandatory unless applicants seek the vesting and processing
benefits offered under SB 330. Participation in the SB 330 streamline process would occur first,
followed by the formal development application process required under Government Code (Gov.
Code)§§ 65940, 65941, 65941.5, and Carlsbad Municipal Code (CMC) § 21.42.050. Acceptance by
the city of a complete SB 330 Streamline Application (Form P-32) and fee will vest the project for
180 days in accordance with the ordinances, policies and standards in effect at the time the SB
330 Application is accepted.
Climate Action Plan (CAP). New requirements related to the city's goals to reduce greenhouse
gas (GHG) emissions will likely impact development requirements of this project. A formal
application submittal will need to include a completed CAP Checklist (Form P-30) to determine
what requirements will apply to the project. New GHG reduction requirements are related to
energy efficiency, photovoltaic, electric vehicle charging, water heating and traffic demand
management requirements, as set forth in the California Green Building Standards Code and in
CMC Chapters 18.21, 18.30 and 18.51 which is available on the city's website at the following
address:
http://www.qcode.us/codes/car1sbad/view.php?topic=18&frames=on
To the extent that new GHG reduction requirements are in effect at the time of application for
grading or building permits, the project will be required to comply with the effective requirements
even if different than what is proposed in the project's planning approvals. GHG reduction
requirements may impact, but are not limited to, site design and local building code
requirements. If incorporating new GHG reduction requirements results in substantial
modifications to the project after planning approvals are obtained, then prior to issuance of
grading or building permits, the applicant may be required to submit and receive approval of a
Consistency Determination or an Amendment application for the project through the Planning
Division.
Stakeholder Outreach. If Planning Commission approval is required, the project will be subject to
City Council Policy Statement No. 84, Development Project Public Involvement. A notice sign is
required to be posted onsite by the applicant and an early public notice is required to be prepared
by the applicant and mailed to all owners located within a 600-foot radius of the property. In
PRE 2023-0053 (DEV2022-0213) -SUNNY CREEK
December 12, 2023
Page 14
addition, enhanced stakeholder outreach and a follow-up summary report are required. Please
see attached Policy for details.
https://www.carlsbadca.gov/home/showpublisheddocument/266/63 7 425976535170000
All necessary application forms, submittal requirements, and fee information are available at the Planning
counter located in the Faraday Building at 1635 Faraday Avenue or online at
https://www.carlsbadca.gov/departments/community-development/permits-applications-forms
you may also access the General Plan Land Use Element and the Zoning Ordinance online at the website
address shown; select Department Listing; select Planning Home Page. Please review all information
carefully before submitting.
Landscaping:
Please advise the applicant to make the following revisions to the plans so that they will meet the
requirements of the City of Carlsbad's Landscape Manual.
Numbers below are referenced on the red line plans where appropriate for ease in locating the area of
the comment concern.
1. As the project progresses please coordinate between the architectural plans, engineering plans
and landscape plans for all site layout to be consistent. Please include all easements, utilities,
storm drains, property lines, grading, etc. on the landscape plans. Please make sure no trees are
located within public utility easements.
2. Please show the general location of the proposed irrigation meter for the project. Please
coordinate with the civil engineer for their plans to also show the meter location. It is assumed
that this project will use recycled water for irrigation. Please confirm.
3. Please include all vehicular sight lines, sight triangles, including intersection site distance corridors
and Ca/Trans sight distance standards (i.e.: stopping sight distance). Coordinate with the civil
engineer to show and label this information on the conceptual landscape plans.
4. Please correct the overlapping text associated with the bar scale. Please check all sheets.
5. Plans are too conceptual to provide an appropriate review. Please show a range of tree, shrub
and ground cover symbols. Provide a separate symbol for each type of tree (large, or small
flowering, etc.), type of shrub (i.e. large evergreen shrub, medium size shrub, small flowering
accent shrub, etc.) and ground covers. Please provide a list of general proposed species for each
plant category. Final comments are reserved pending receipt of more complete plans.
6. As the planting legends are developed (per above comment), please include all common and
botanical plant names, tree types and quantities, shrub types and spacing with general layout,
ground cover types and spacing, and include the WUCOLS IV plant water use categories for all
proposed plant species.
PRE 2023-0053 (DEV2022-0213) -SUNNY CREEK
December 12, 2023
Page 15
7. Please provide a Maintenance Responsibility·-Exhibit. The Maintenance Responsibility Exhibit shall
be prepared at a scale and size (preferably one sheet) that provides an overall view of the project
and shall clearly identify the various areas of landscape maintenance responsibilities (private,
common area/homeowners" association (HOA), City, etc.).
8. The Landscape Manual indicates that landscape plans are to feature ground cover, shrubs, and
trees to screen elements of unsightliness and screen/soften new improvements. The Landscape
Manual also indicates that landscaping shall be used to accentuate and enhance architecture. A
significant amount of tree planting along the frontages of all roads (particularly ECR and College
Blvd.) will be needed to screen and soften the project.
9. Please add a note to the plan to specify that any trees located within a vehicular sight line must
have all limbs removed to a height of 6 feet above the adjacent top of curb.
10. Please add a note to the plan to indicate that all utilities are to be screened. Landscape
construction drawings will be required to show and label all utilities and provide appropriate
screening.
11. The City of Carlsbad Landscape Manual requires that street trees be provided at a minimum of
one tree for every 40' of street frontage. Trees may be planted on center or grouped. It appears
that street trees are proposed on College Blvd., but they are not proposed for El Camino Real or
Sunny Creek Road. The status of Sunny Creek Road improvements is not clear. Please add street
trees where needed (meet the 1 tree per 40 feet requirement) on all frontages.
12. Street Trees shall be located:
a. A minimum of seven (7) feet from any sewer line.
b. In areas that do not conflict with public utilities.
c. Outside of sight distance areas.
d. Within the street Right-of-Way.
13. Street Trees shall be selected from the approved tree replacement list identified in Chapter 6 of
the Carlsbad Community Forest Management Plan, unless approved otherwise. For ECR and
College Blvd, see comment below.
14. El Camino Real and College Blvd. are "Themed Streets" with established tree species identified in
the landscape manual. Per the landscape manual, and as identified on the plans, For College Blvd.,
Cinnamomum camphor is the theme tree. Per the landscape manual, 50% of the Street Trees
should be this species. In addition, "Support" tree species are identified in the landscape manual
and should be represented as 30% of the Street Trees. The support tree species are Eucalyptus
species and/or Liriodendron tulipifera. For El Camino Real, the theme tree is Lophostemon
confertus, and the support trees are Eucalyptus species, Eriobotrya deflexa, Pi nus canariensis, and
Lophostemon confertus. In addition to the "theme" and "support" species, 20% of the Street
Trees may be proposed by the Applicant as "Project Identity/Accent Trees". The Applicant may
choose the best tree for the project and submit if for approval.
15. All Street Trees must be 24"box minimum size and single trunk.
PRE 2023-0053 (DEV2022-0213) -SUNNY CREEK
December 12, 2023
Page 16
16. It appears that most all parking on site include shade covers. Therefore, the requirement of 1 tree
per 4 parking spaces will not be applied to covered spaces. It is noted that there are a few parking
area finger islands that do not include a tree, while others in similar situations do include trees.
Please include trees for all the finger islands.
17. Per the Landscape manual, where landscaped "finger'' islands are provided between parking
spaces, they shall be designed with a minimum outside width of seven (7) feet and a minimum
landscape width of four (4) feet. It is noted that some (or most) of the finger islands are less than
7' in width. Please enlarge the islands.
18. Parking areas shall be screened from adjacent property or streets through the use of planting or
any combination of planting, mounding, and decorative walls. Screening elements shall have a
total height of at least three (3) feet. Please indicate on the plans the appropriate planting or
other methods of screening per this requirement.
19. Per the landscape manual, a minimum of 3% of the parking area shall be landscaped. The "parking
area" includes all parking spaces and drive aisles. The plantings shall be contained in planting
areas with a minimum dimension of 4' and bounded by a concrete or masonry curb of a minimum
of 6" in height. The plantings shall be located throughout the off-street parking areas in order to
obtain the maximum amount of dispersion. Please provide a calculation showing the percentage
of landscape area provided in the parking area.
20. Please provide a Water Conservation Plan in conjunction with the Landscape Concept Plan. This
plan shall demonstrate to the City how the proposed development will use all practical means
available to conserve water in the landscape. Please provide/address the following:
a. Please indicate the proposed type of water to be used for irrigation (i.e. potable, recycled,
graywater, etc.).
b. Please provide a colored or hatched plan clearly showing where recycled water,
graywater and potable water are proposed to be used for irrigation. This plan will be
forwarded to Carlsbad Municipal Water District (CMWD) for review. Any comments will
be returned to the applicant.
c. Irrigation systems for all projects, except for service to a single-family residence or front
yard irrigation on individually metered condos, shall be designed to use non-potable,
treated recycled water, unless an exemption is approved by the City Utilities Department.
d. Please provide written descriptions of water conservation features including addressing
xeriscape principles (see Appendix A of the Landscape Manual) within the project.
e. Hydrozone Diagram: Please include one "Hydrozone Diagram" which identifies grouping
of plants within the individual hydrozones (high, moderate, low, very low or special
landscape areas) and which indicates the square footage and irrigation method of each
area.
f. 'Separate water service for landscaping (including, but not limited to connections, water
meters, and back flow preventers) shall be provided for all commercial/industrial
projects, golf courses, parks, and residential common areas in projects over four (4)
dwelling units.
g. Concept plans shall include calculations which document the maximum allowed annual
water use for the landscaped area or maximum applied water allowance (MAWA) and
estimated total water use (ETWU). A landscape project shall not exceed the MAWA. The
PRE 2023-0053 (DEV2022-0213)-SUNNY CREEK
December 12, 2023
Page 17
MAWA for a landscape project shall be determined by the following calculation as defined
in the City ordinance: MAWA = (ETo)(0.62)((0.55 x LA)+ (0.45 x SLA)]. The ETWU shall be
determined by the following calculation as defined in the Landscape Manual:
Please provide calculations and worksheets on city forms as found in the Landscape
Manual.
In addition to the calculations, include a statement on the plans signed under penalty of
perjury by the person who prepared the plan that provides:
"I am familiar with the requirements for landscape and irrigation plans contained in the
City of Carlsbad's Landscape Manual and Water Efficient Landscape Regulations. I have
prepared this plan in compliance with those regulations and the landscape manual. I
certify that the plan implements those regulations to provide efficient use of water."
Please provide a line beneath this statement for signature and date.
21. The plan shall provide that only subsurface irrigation shall be used to irrigate any vegetation
within twenty-four inches of an impermeable surface unless the adjacent impermeable surfaces
are designed and constructed to cause water to drain entirely into a landscaped area. Please add
a note to this effect.
22. Please add the following notes to the plans and insure all requirements are met:
Slopes 6:1 or steeper requiring erosion control measures as specified herein shall be treated
with one or more of the following planting standards:
a. Standard 1-Cover Crop/And Erosion Control Matting:
Cover crop shall be a seed mix typically made up of quick germinating and fast
covering grasses, clovers, and/or wild flowers. Submit the specific seed mix for City
approval prior to application. The cover crop shall be applied at a rate sufficient to
provide 90% coverage within thirty (30) days.
The type of erosion control matting shall be as approved by the city and affixed to the
slope as recommended by the manufacturer. On slopes 3
feet or less in vertical height where adjacent to public walks or streets:
When planting occurs between August 15 and April 15, erosion control matting
shall be required.
During the remainder of the year, the cover crop and/or erosion control matting
may be used.
On slopes greater than 3 feet in height, erosion control matting shall be required and
a cover crop shall not be used, unless otherwise approved by the City.
b. Standard #2 -Ground Cover
One hundred (100%) percent of the area shall be planted with a ground cover known
to have excellent soil binding characteristics (planted from a minimum size of flatted
material and spaced to provide full coverage within one year).
c. Standard #3 -Low Shrubs
PRE 2023-0053 (DEV2022-0213)-SUNNY CREEK
December 12, 2023
Page 18
Low spreading woody shrubs (planted from a minimum of 1-gallon containers) shall
cover a minimum of seventy (70%) percent of the slope face (at mature size).
d. Standard #4-Trees and/or Large Shrubs
Trees and/or large shrubs shall be (planted from a minimum of 1-gallon containers)
shall be installed at a minimum rate of one (1) plant per two hundred (200) square
feet.
Slopes -6:1 or steeper and:
a. 3' or less in vertical height and adjacent to public walks or streets require at a
minimum Standard #1 (cover crop or erosion control matting).
b. 3' to 8' in vertical height require Standards #1 (erosion control matting shall be
installed in lieu of a cover crop), #2 and #3.
c. In excess of 8' in vertical height require Standards #1 (erosion control matting
shall be installed in lieu of a cover crop), #2, #3, and #4.
Areas graded flatter than 6:1 require a cover crop per Standard #1 with temporary irrigation
when they have one or more of the following conditions:
a. Sheet graded pads not scheduled for improvements within 6 months of completion
of rough grading.
b. A potential erosion problem as determined by the City.
c. Identified by the City as highly visible areas to the public or have special conditions
that warrant immediate treatment.
23. PLEASE RETURN REDLIN ES and provide 2 copies of all plans (concept and water conservation), for
the next submittal. The submittal must be made to a Planning Division staff member at the
Planning counter along with a transmittal clearly indicating what the submittal is for (i.e. Pre-
Concept drawing re-submittal}. Appointments for all landscape submittals. both new submittals
and resubmittals, are required. Please link to www.carlsbadca.gov/cdappointments to make a
submittal appointment. Please provide a written response to all comments clearly indicating
where and how each comment was addressed.
Land Development Engineering:
Land Development Engineering Division staff has completed a preliminary review of the above-referenced
project. Prior to formal application submittal the following items must be adequately resolved/addressed:
1. Complete a Stormwater Standards Questionnaire Form E-34. This questionnaire will guide you and
the City in determining what type of reports and storm water mitigation must be completed to
satisfy state and City storm water quality requirements. The questionnaire is located on the City
of Carlsbad website.
Based on a preliminary analysis it appears that this project is a Priority Development Project (PDP),
all impervious surfaces being created or replaced (onsite and offsite) shall be included for
treatment. The post construction stormwater treatment BMPs shall be designed per the City of
Carlsbad BMP Manual and shown on a conceptual grading plan and drainage plan with the
discretionary application.
PRE 2023-0053 (DEV2022-0213) -SUNNY CREEK
December 12, 2023
Page 19
2. Prepare a Preliminary Storm Water Quality Management Plan utilizing the stormwater template E-
35 on the City of Carlsbad website. This project is subject to designing and installing numerically
sized water quality basins per Chapter 5 of the Carlsbad BMP Design Manual, in addition to
installing site design and source control best management practices (BMP) per Chapter 4 of the
Carlsbad BMP Design Manual. Worksheets in the manual shall be used to size the proposed water
quality basin shown on the site plan. The project appears to be subject to flow control (Chapter 6
Hydromodification) as well.
3. If utilized on site, compact biofiltration facilities must meet the design requirements set forth in
Appendix F of the City of Carlsbad BMP Design Manual. Proprietary biofiltration facilities must be
plantable. Additionally, site design BMPs (like rain barrels and tree wells) shall be designed to meet
the retention requirements of a traditional Biofiltration facility. BMPs must be located in common·
areas and unrestricted access for City staff shall be provided to enforce maintenance and
effectiveness of the BMP.
4. Based on the proposed General Plan Land Use designation, R-30, this project is subject to the City
of Carlsbad trash capture requirements. Incorporate trash capture measures on the project plans.
Provide trash capture calculations and incorporate in the Storm Water Quality Management Plan.
5. A preliminary hydrology study will be required to determine the pre-development and post-
development discharge flows. Provide preliminary recommendations to mitigate any increase in
flows.
6. Provide a preliminary Geotechnical study that identifies feasibility and recommendations for the
proposed project including design recommendations for proposed pollutant control BMPs and
hydromodification facilities.
7. A recent Preliminary Title Report (PTR) will be required with formal project application submittal.
8. All easements and encumbrances identified in the PTR must be indicated on the site plan.
9. Show complete property boundary data on the site plan, including bearings and distances.
10. Show locations of all existing public utilities within El Camino Real and College Blvd., including
water main, fire hydrant, water services, water meters, sewer main, sewer laterals, and their
appurtenances. Reference the drawing numbers of the city approved improvement plans and
identify materials and sizes.
11. On the site plan, show and identify all existing surface improvements (curb, gutter, sidewalk,
paving, manholes, inlets, street lights, adjacent driveways, vaults, transformers, etc.) at the project
frontage and within 100 feet.
12. Show existing and proposed contour lines onsite and extend a.t least 100 feet beyond property
lines.
13. Show the locations of all existing and proposed buildings, walls, fences, and permanent structures
onsite and within 100 feet of site.
PRE 2023-0053 (DEV2022-0213)-SUNNY CREEK
December 12, 2023
Page 20
14. Provide multiple cross-sections of the site to demonstrate differences in grade, including adjacent
properties. Provide a typical street cross section of El Camino Real and College Blvd. showing
existing improvements.
15. Indicate the volume of grading (cut, fill, import, export, remedial) proposed for the project in cubic
yards.
16. Show spot elevations and method of drainage for the site, including storm drains, gutters, swales
and basins.
17. Show proposed finished floor elevations for structures.
18. Contact Nick Gorman in the Traffic Division at Nick.Gorman@carlsbadca.gov, a division of the
Public Works Department, to determine if a Scoping Agreement is required. Scoping Agreements
are used to determine if a Local Mobility Analysis is required and the scope of analysis. With your
response to these comments, submit one or the other 1) an approved Scoping Agreement, or 2)
correspondence from the Traffic Division indicating one is not required. In order to assess the
applicability of this requirement, provide ADT and peak hour trips per generation rates from
SAN DAG Brief Guide of Vehicular Traffic Generation Rates for the San Diego Region. Include this
information on the site plan/tentative map.
If a Local Mobility Analysis is required, refer to the Transportation Impact Analysis Guidelines at
https://www .ca rlsbadca .gov /home/showpu b I isheddocu me nt/328/637 425982502330000 .
19. Depending on the CEQA determination, which is determined after the application for
discretionary permits is submitted, a Vehicle Miles Traveled (VMT) analysis may be required per
the Vehicles Miles Traveled Analysis Guidelines available
at https://www.carlsbadca.gov/home/showdocument?id=312.
20. Submit a Climate Action Plan (CAP) checklist, form P-30 to demonstrate that this project is in
compliance with CAP. If applicable per checklist, include a Transportation Demand Management
(TDM) Plan and Greenhouse Gas (GHG) Analysis with discretionary application. Delineate all
electric vehicle (EV), EV Ready, and EV capable parking spaces and charging station on the site plan.
21. The northern section of the property is in a flood hazard zone. It appears that the base flood
elevations do not coincide with the existing grades on the property, so a LOMR may be filed to
reduce the impacts of this flood zone. No fill may be placed in the flood zone without permission
from FEMA.
22. Coordinate with the Fire Department to identify all necessary fire protection measures required
for this project. Show the locations of the proposed private fire service and fire hydrants on the
site plan.
23. Provide sidewalks per City of Carlsbad General Design Standards, Section 4.4.
PRE 2023-0053 (DEV2022-0213) -SUNNY CREEK
December 12, 2023
Page 21
24. The entrances to the planned developments shall be designed in accordance with the City of
Carlsbad General Design Standards, Section 4.2.
25. Pursuant to LOCAL FACILITIES MANAGEMENT PLAN AMENDMENT ZONE 15 (E):
Drainage
A. All future development in Zone 15 will be required to construct any future Zone 15 storm
drain facilities identified in the July 2008 Drainage Master Plan. Any facilities necessary to
accommodate future development must be guaranteed prior to the recordation of the first
final map, issuance of a grading permit or building permit, whichever occurs first in Zone
15. (Note: Facility identification below taken from July 2008 Drainage Master Plan).
B. Prior to the recordation of any final map, grading permit or building permit (whichever
occurs first), for any specific project within Zone 15, the developers of that project are
required to:
1. Pay the required drainage area fees established in the current Drainage Master Plan
and;
2. Execute an agreement to pay any drainage area fees established in the forthcoming
revised Drainage Master Plan.
C. Prior to the recordation of the first final map, issuance of grading permit or building permit,
whichever occurs first within Zone 15, the developers are required to financially guarantee
Zone 15's proportional share of the following to the satisfaction of the City Engineer:
1. Sediment detention basin "BJ-1" to be installed in Zone 15 upstream of College
Boulevard along with a 4' x 7' box culvert under College Boulevard and an unlined
channel within basin "BJ-1".
2. Provide a mechanism for the maintenance of the "BJ-1" sediment detention basin.
3. Remove the existing headwall of the 78" RCP in College Boulevard (BL-L) and connect
to Agua Hedionda Creek just downstream of the proposed bridge.
4. Bridge on College Boulevard at Agua Hedionda Creek (BL-L).
5. Drainage project BR a 66 inch culvert under College Boulevard North of Bridge BL-L
to drain an un-named creek coming from Cantarini and Holly Springs Development.
College Boulevard
Prior to recording a final map or the issuance of a grading permit or building permit, the applicant
shall enter into a secured financial agreement in a form acceptable to the City Council that will
secure its fair share of the cost of College Boulevard between the northern boundary of
Development Area 4 to Cannon Road.
Sewer Collection
All development in Zone 15 is required to pay the appropriate sewer connection fees and sewer
benefit area fees prior to 1ssuance of any building permit.
28. The City of Carlsbad has plans to widen El Camino Real in this area as soon as next year. Coordinate
proposed improvements with the proposed El Camino Real plans.
PRE 2023-0053 (DEV2022-0213) -SUNNY CREEK
December 12, 2023
Page 22
29. Address the existing storm drain outfall in the southwest corner of the site. Show how offsite
stormwater will be conveyed and where.
30. Private street Sunny Creek Drive shall be designed in accordance with the City of Carlsbad General
Design Standards, Section 4.1.
31. Please be advised that in order to make a more in-depth review of the proposed development, a
more complete design of the project is required.
Public Works-Utilities:
1. Submit a water study, analyzing existing and proposed demands for the public water distribution
system. Water study to include domestic meter and fire sizing criteria, as well as modeling of
public distribution system in response to on-site water demands per the CMWD 2019 Potable
Water Master Plan and fire flow requirements per CFC Table B105.1 as modified by the City of
Carlsbad fire department. It is noted that a zoning change is being processed for this project,
which will require CMWD modeling the development impacts to the existing water system at the
developer's expense and may trigger off-site water improvements as a condition of approval.
2. Submit a sewer study analyzing existing and proposed demands for the public sewer main. Model
the demands and performance criteria of the sewer per the City of Carlsbad 2019 Sewer Master
Plan and City of Carlsbad Volume 1 Engineering Standards. It is noted that a zoning change is
being processed for this project, which will require Carlsbad modeling the development impacts
to the existing sewer and pump station at the developer's expense and may trigger off-site sewer
improvements as a condition of approval.
3. Show proposed fire, water, and irrigation connections with meter and backflow sizing. Reclaimed
water is available in College Blvd. frontage and will be required for irrigation purposes.
4. A public potable water main in Sunny Creek Road along project frontage must meet minimum
design diameter and material as specified in City of Carlsbad Engineering Standard Vol. 2 Section
3.2.2 for water and Volume 1 Section 6.2 for sewer. Utility replacement and/or upsizing may be
required as a condition of development.
5. See attached red lines for additional comments.
Housing and Homeless Services:
1. Density Bonus -Please clarify whether a Density Bonus under Government Code Section 65915 is
being requested. If so, please provide density calculations and relationship to lnclusionary Housing
Ordinance for provision of affordable housing units.
2. lnclusionary Requirement -Project is subject to Carlsbad Municipal Code Chapter 21.85 and is
subject to Planning Commission Resolution No. 7114-which increases the percentage of affordable
units required for certain parcels from 15 percent of the total residential units to 20 percent of the
total residential units. This project (APN 209-090-11) is required to provide a minimum of 20 percent
of the total residential units to be affordable for lower income households. The applicant should
PRE 2023-0053 (DEV2022-0213) -SUNNY CREEK
December 12, 2023
Page 23
use the following calculations to comply with lnclusionary Housing Ordinance and Planning
Commission Resolution No. 7114:
For-sale residential
For-rent residential
9.6 acres
8.09 acres
166 units x 20% = 33.2 units, rounds to 33 units
250 units x 20% = 50 units
Total: 426 units x 20% = 83 affordable units total
Applicant has proposed 29 affordable units as part of the for-sale residential, which is less than 20
percent required of the project. The applicant did not indicate number of proposed affordable units
as part of the for-rent residential, but it must be a minimum of 50 units.
The project is required to provide 83 affordable units, and per CMC 21.85.030 (C), a minimum of 10
percent of the affordable units shall have three or more bedrooms. The project is required to
provide 83 inclusionary units x 10% = 8.3 units, rounds down to 8, three-bedroom unit is required.
Additionally, per CMC 21.85.040 (G) -inclusionary units shall be reasonably consistent or
compatible with the design of the total project in terms of appearance, materials, and finished
quality. Additionally, the affordable unit bedroom counts should be commensurate with the
market-rate unit bedroom counts.
3. Affordable Unit Distribution -Applicant should be aware that State law (Health and Safety Code
Section 17929 ("AB 491")) requires the affordable units to be distributed equitability throughout
the project.
Health and Safety Code Section 17929 (a)(2) citation:
(a) (1) For a mixed-income multifamily structure, both of the following shall apply:
(A) The occupants of the affordable housing units within the mixed-income
multifamily structure shall have the same access to the common entrances to that
structure as the occupants of the market-rate housing units.
(B) The occupants of the affordable housing units within the mixed-income
multifamily structure shall have the same access to the common areas and
amenities of that structure as the occupants of the market-rate housing units.
(2) A mixed-income multifamily structure shall not isolate the affordable housing units within
that structure to a specific floor or an area on a specific floor.
Public Works-Traffic:
1. Please submit a Scoping Agreement pursuant to the latest city of Carlsbad Transportation Impact
Analysis Guidelines.
2. Project Trip Generation-provide average daily and peak hour traffic generated by the project. For
the proposed land use trip generation, please utilize SANDAGs Not-So-Brief Guide of Vehicular
Traffic Generation Rates.
PRE 2023-0053 (DEV2022-0213) -SUNNY CREEK
December 12, 2023
Page 24
Fire Prevention:
Any comments received from the Fire Department will be provided under a separate cover.
Building:
The following comments are provided courtesy of the Building Division and will need to be clearly detailed
in your final design prior to submitting for building permit construction plan review. The Building Division
will not need to see these preliminary plans again:
1. Carlsbad requirements:
CLIMATE ZONE 7
SEISMIC (R=6.5) = .12 W; SDC = D; SDS ~ .75, :Sl.00; D1/D2
RAINFALL ("/hr.): 3.7"
WIND VELOCITY: 96mph
2019 California codes are adopted until December 31, 2022.
2022 codes take effect on January 1, 2023.
2. This project consists of building with more than three dwelling units and will be subject to CBC
Chapter 11A and/or 118 accessibility requirements and other Federal accessibility requirements
depending on the funding source(s). New apartments of three or more dwellings per building and
new condominiums of four or more dwellings per building are defined as covered multifamily
dwellings subject to CBC Chapter 11A accessibility requirements for accessible/ adaptable units.
3. Government funding (if applicable) will trigger HUD section 504 accessibility requirements.
4. Funding sources such as CTAC may trigger additional accessibility requirements above the minimum
amounts required by the California Building Code. Please list those additional requirements, if
applicable, in chart form on the cover sheet and provide details on the plans.
5. Clearly define these dwelling as apartments or condominiums for the plan review process to
determine accessibility requirements. (New apartments of three or more dwellings per building and
new condominiums of four or more dwellings per building are defined as covered multifamily
dwellings subject to CBC Chapter llA accessibility requirements for accessible/ adaptable units).
6. Show details for airborne and structure borne sound transmission compliance with CBC section
1206 for the walls and floors separating dwellings.
7. This project will trigger Carlsbad Climate Action Plan compliance for the following:
a. New residential required to comply with sections 18, 2B, 3B, 4A.
b. New commercial required to comply with sections 18, 2B, 3B, 4B, 5.
c. Clearly detail these separate requirements on the plans.
d. Each new parking facility will require accessible stalls per llB-208 for parking facilities with
public access, and 1109A for residential areas (not available to the public).
e. Each new parking facility will require EV parking stalls per Green Code 4.106 or 5.106
(depending on residential assigned/unassigned or public accommodation), and accessible EV
stalls per 11B or 1109A. (APPLICATIONS DATED JANUARY 1, 2023 OR LATER WILL BE
REQURIED TO COMPLY WITH THE 2022 GREEN CODE REQUIREMENTS FOR EV PARKING:25%
EV READY, 10% EV CAPABLE, 5% EV CHARGER INSTALLED).
PRE 2023-0053 (DEV2022-0213) -SUNNY CREEK
December 12, 2023
Page 25
f. Clearly designate which parking facilities are for housing (assigned/unassigned) and for public
use. Provide parking stall charts for accessible, EV and accessible EV stalls for each facility,
including 2% of private garages.
8. A soils report is required for new construction. Prepare the report and include recommendations
into the foundation design.
9. A boundary certification is required for new structures built 5 feet or closer to a side or rear yard
property line.
10. Sewer design with fixture unit counts for entire sewer system to be included in complete plumbing
plans.
11. Gas line isometric for proposed gas fixtures to be included in complete plumbing plans.
12. Electrical load calculations and single line diagram for entire electrical design to be included in
complete electrical plans.
13. This is a preliminary review that has been done for the benefit of the design team. If this project
moves forward for building permits, the above details should be clearly shown on the plans for plan.
If you would like to schedule a meeting to discuss this letter with the commenting departments, please
contact Shannon Harker at the number below. You may also contact each department individually as
follows:
• Planning Division: Shannon Harker, Senior Planner, at (442) 339-2621
• Land Development Engineering: Tim Carroll, Project Engineer, at (442) 339-2737
• Public Works-Utilities: Neil Irani, Associate Engineer, at (442) 339-2305
• Fire Department: Randy Metz, Fire Marshal, at (442) 339-2661
Sincerely,
ERIC LARDY, AICP
City Planner
EL:SH:ES
Enc: Engineering civil plan redlines
Landscape plan redlines
c: Tim Carroll, Project Engineer
Laserfiche/File Copy
Data Entry