Loading...
HomeMy WebLinkAbout2456 TOWN GARDEN RD; ; CBC2018-0507; Permit{City of Carlsbad Print Date: 10/03/2019 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: II Dwelling Units: Bedrooms: Project Title: 2456 Town Garden Rd BLDG-Commercial 2132601100 $150,000.00 Commercial Permit Work Class: Cogen Lot II: Reference II: Construction Type: Bathrooms: Orig. Plan Check II: Plan Check II: Description: VIASAT: INSTALL 19 ELECTRIC VEHICLE CHARGERS IN PARKING GARAGE Applicant: Owner: ARATI RANGASWAMY VIASAT INC A DELAWARE CORPORATION 858-793-4777 BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) 6155 El Camino Real CARLSBAD, CA 92009 760-476--2200 ELECTRICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL FIRE Special Equipment (Ovens, Dust, Battery) SB1473 GREEN BUILDING STATE STANDARDS FEE STRONG MOTION-COMMERCIAL Total Fees: $1,919.95 Total Payments To Date: $1,919.95 Status: Applied: Issued: Permit Finaled: Inspector: Final Inspection: Balance Due: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/e)(actions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. Permit No: CBC2018-0507 Closed -Finaled 09/05/2018 06/25/2019 10/3/2019 2:11:12PM $0.00 $803.50 S562.45 $89.00 $417.00 S6.00 $42.00 1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: □PLANNING □ENGINEERING □BUILDING OARE □HEALTH 0HAZIIATIAPCD { City of Blllldlng Permit Appllcatlon Plan Check No.(x(...201£;-D:YJ-1 1635 Faraday Ave., Car1sbad, CA 92008 Est. Value \~1 1 QCfJ -. CarlsbadP--1. Ph: 760-602-2719 Fax: 760-602-8558 Plan Ck. Deposit email: building@car1sbadca.gov www.carlsbadca.gov Date %--~'"\--· \"r\ ISWPPP JOB ADDRESS IUIIDJU'ACE•JUNffll rPN 213 2456 Town Garden Road, Carlsbad CA 92009 -260 -02 - CT/PROJECT# rOT# r~·· I# OF UNITS I# BEDIVNMS #BATHROOMS ,lEIWff-llAME I CONSTR. ,_ I ooc. GROUP 1-B 5-2 DESCRIPTION OF WORK: lnclade Squa,e Feet or M'IKCw AIN{a) INCLUDES ELECTRICAL WORK ONLY FOR PROPOSED EV CHARGERS: TOTAL OF (17) DUAL PORT ANO (2) SINGLE PORT CHARGERS. EXIS11N8 UIE !PROPOSED USE !GARAGE (SF) PATIOS (SF) I DECKS (SF) RREPI.ACE I AIR CONDITIONING IRRE SPRINKLERS Parking Garage N/A 209,524 YESD Ne@ YESONO[Z) YES@N<O APPLICANT NAME Arati Rangaswamy PIIOPERIY OWNER NAME ViaSat Inc. 3 'JIJ.:\"'t·APEIMD ADDRESS ADDRESS vening Creek Dr. Suite 12513280 Evening Creek Dr.I!!! 6155 El Camino Real CllY STATE ZIP cnv STATE ZIP San Diego CA 92128 Carlsbad CA 92009 PHONE !FAX PHONE rAX 858.793.4777 760.476.2200 EMAIL EMAIL aratir@sca-sd.com bob.rota@viasat.com DDIGN PROFESSIONAL SCA Architecture CONTRACl'OR BUS. NAME RE QJ,>ffft_ E~crl2t<:.-, /-U~_ ADDRESS ADDRESS J>o 13280 Evening Creek Dr. Suite 125 ~x 1'-t( CllY STATE ZIP Cl1Y STATE ZIP San Diego CA 92128 $.P'_KI:-VC .. ~cl,€--,/ CA-q, 1-J( PHONE IFAX PHONE , IFAX 858.793.4777 6/"i•L/5-3/-63-5.S-,,-V/_.d EMAIL EMAIL re A. /s:tereled,,/c/:-' v~,/~, c.,......-, 1STATEUC.c 11101 STATELIC.# -f~n, r I cnv BUS. UC.# g~ >>C'i l?u.:>5 l:?~061/0 [Sec. 7031.5 Busmess and Professions Code: Any Cl!)' or~ which requires a ~It ta construct. alter, Improve, demolish or repair any structure, Dlfor to its issuance-'-l!!so rt,qulres the applicant for such permit to file a slaned statement tnat he is licensed pursuant to the provisions of the Contrai::tDr's Lice,-Lew IChar>ter 9, commendlnl with Section 7uuu of DMsion 3 of the Business and Professions Code} or that he is mcem_P.t therefrom, and the basis for the alleged exemption. Any violation of Section 1031.5 II'/ any appllcanflor a permit subjects the appllcant to a civil penalty of not more than five hundred dollars {$500}). WCll'kn' Companullon Declll'lllan: / helllly atlfnn !Rider penally of pe{jutyfllll of 1118 fdloVling dedelllionB: . Q I have ■nd will malnt■ln a catlllcate of canalllt lD Hlf.lnaunt forWDlktn' eompenll8lion 18 pnr,idad by Section 3700 of the Labor Code, far Iha parfonnanc:e ol lhe work for whic:h this plllfflil ii iaued. ):d_.1 hlVII and wll maintain WOiken' COIIIPIIIUllon, as IIQllired bv Section 3700 of the \abor Code. for the perfomlan~ of the work for which lhis pennil.is iuued. Mywork1111' compallllltion ilalnnca c:anter and policy oomber818:lnauranceCo. 5EC1.-"lf'rq /f/,a.,no,r./AL :Tv,s-. La, PolicyNo. S.WG I~ 3t/S:: ElipqlionDate 7·-3/ -, c; lblf. seclion need not be completed if the perml is for one hundred dollara ($100) or less. LI Clrllfleate of Enmpllon: I certify that In Iha petformanc:a of the work for whk:ll this permit Is Issued, I lhall not .,....iloy any pnan In any ll'IIINr ao •• to blcame subjecuo the WOlkn' COrrfle111811Dn t... of Calllomla. WARNING: Fallun to IIICllfl ---· campanlllkln co.,. It untawful, 111d .., .. IUbJect III llllploym' to cdmlnal pllllllel ■nd clvll hi up to one hundr.i ...... d dGllus (&108,DIO), In addition lD 1h11 -t of CCllllplllAllon, dlffllllllS ~ for n Section ,!' of lhl Labar eode, 111W and llllarMJ'• flll. _.s CONJRACTOR SIGNATURE ,f" E, /4~:c...···--- I hMby llfflml Illa! I am mmp! tiolll Canlractor's L.icensl Law for Ille h'lowlllg 181101!: 0 I, as owner of the property or my employHS wilh wages as !heir sole compensation, \\111 do Iha work and the etnll:Wre Is not ln1ended or ollenld for sale (sec. 7044, BIIHHl88 and P!ofeeslons COde: The Conhctol's License Law does not apply to an C7Mler ol property Who builds or Improves tllenlan, and who does 8Udl work himself or through Iii awn employaes. pnwided that IUCh impnwementa are not intended or afferad far sale. If, however, the building or Improvement i8 BOid within 0!1B year ol completion, the owner-builder will have Iha burden of pnl'ling that he did not Ill.id or improve far IHI IJIIP088 ol sale). □ I, as owner of Iha property, am exclu&iWly cantradlrv wilh Mcensad cantracloll to construct Iha projed (Sec. 7044, BuainlSS and Profassions Code: The Conlractor's License Law don nat apply ID III DW1111r of property who huilds or Improves lllanlon, and COn1rads far auch projects with conlrador(s) licensed pursuant ID Iha Conlractor's License law). D I am exempt under Sadian ____ Bllllness and Profession& Code for this niaBOO: I. I personally plan to provide Iha major labor and ma1erials for c:onslnK:lion of the PfDP08'-'d property improwment. CJves O,o 2. I (have I h8Ve not) sjgnad an application for II blllding permit for Iha praposed work. 3. I have tontracted with Iha lolloWing person (!inn) to p!D'lide Iha proposed construdion Onc:lude name addrass / phone/ conbaelar8' license oomber): 4.1 plan ID provide pol1ions of the work, but I have hired the fllllowlng person to coafdinata, aupeM88 and provide Iha mejor 'Mll1c (ild!Jde name/ addn111 /phone/ ml\raclOrS' lic.en8a numbar): 5. I will provide SOl11II of Iha work, but I have conlrBded (hired) lhe fol\cMhg pan1011s to provide !he work indlcaled Ondude name/ address/ phone/ !)'pa of 'Mll1c): ,6 PRDPER1Y OWNER SIGNATURE DATE <OMPLET£ THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY Is the applicant or ~U(8 bullding oc:cupant required ID submtt a busin-plan, acute\' hazardous materials regstration form or risk management and prewnllon program under sedions 25505, 25533 or 25534 of the Presley•ll'rmer Hazardous Subslance AccllUnt Adi Yes ., No Is \he aPi/icant or future building DCCUpanl 1eqllm!d ID obtain a permit from the mr pollulion con1rol district or aif quality management cisttict? Yes ., ltJ Is \he IBCilily to be oonstructed within 1,000 feet of \he outer boundary of a school site? Yes ., No IF ANY Of THE ANSWERS ARE Y£S. A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE issum UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES ANO THE AIR POLLUTION CONTROL DISTRICT. I~: l-· ._ ,;; • STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE . Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection. Fax (760) 602-8560, Email building@carlsbadca.gov or MaU the completed form to City or carlsbad, ~ Division 1635 Faraday Avenue, carlsbad, ca1ifumia 92008. COi': (Olfkle u.. Only) CONTACT NAME OCCUPAHJ NAME ADDRESS BUIWING ADDRESS CITY STATE ZIP CRY STATE car1sbad CA P1lONE FAX EMAIL OCCUPANT'S BUS. LIC. No. DELIVERY OPTIONS PICK UP: CONTACT (Ustect above) OCCUPANT (Listed above) CONTRACTOR (On Pg. 1) MAIL 10: CONTACT (Listed above) CONTRACTOR (On Pg. 1) MAIL/ FAX 10 OTHER: OCCUPANT (Listed abova) -----·---- .Jt5 APPLICANT'S SIGNATURE ASSOCIATEDCB•----------- NO CHANGE IN USE/ NO CONSTRUCTION CHANG£ OF USE/ NO CONSTRUCTION DATE ZIP ' , PERMIT INSPECTION HISTORY REPORT (C8C2018-0507} Permit Type: Work Class: Status: Scheduled Date BLDG-Commercial Cogen Closed -Finaled Actual Start Date Inspection Type Application Date: 09105/2018 Owner: Issue Date: 06/25/2019 Subdivision: Expiration Date: 03/31/2020 Address: IVR Number: 13668 Inspection No. Inspection Status Primary Inspector 10/03/2019 10/03/2019 BLDG-34 Rough Electrical 106314-2019 Passed Chris Renfro October 03, 2019 BLDG.final Inspection Checklist Item BLDG-Building Deflciency 106315-2019 Checklist Item BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final COMMENTS Passed Chris Renfro COMMENTS VIASAT INC A DELAWARE CORPORATION 2456 Town Garden Rd Carlsbad, CA 92009-1742 Reinspection Passed Yes Passed Yes Yes Yes Yes '(es Complete Complete Complete Page 1 of1 Carlsbad CBC2018-0507 11/13/2018 DATE: 11/13/2018 JURISDICTION: Carlsbad PLAN CHECK#.: CBC2018-0507 ✓. EsG1I SET: II PROJECT ADDRESS: 2456 Town Garden Road PROJECT NAME: Install 17 Electric Vehicle Chargers for ViaSat D APPLICANT D JURIS. C8J The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: C8] EsGil staff did not advise the applicant that the plan check has been completed. □ EsGil staff did advise the Person contacted: Date contacted: pplicant that the plan check has been completed. _ff'L Telephone#: (b~) Email: Mail Teleph ne Fax In Person 0 REMARKS: By: Morteza Beheshti EsGil Enclosures: 11/6 ✓. EsG1I DATE: 9/17/2018 JURISDICTION: Carlsbad PLAN CHECK#.: CBC2018-0507 PROJECT ADDRESS: 2456 Town Garden Road SETI PROJECT NAME: Install 17 Electric Vehicle Chargers for ViaSat □ APPLICANT f JURIS. D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ~ The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: D EsGil staff did not advise the applicant that the plan check has been completed. ~ EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Arati Telephone#: 858.793.4777 ,,--.Qa~=tac:~e1!_d:: '1/ll?/IK' (b~) Email: aratir@sca-sd.com Mail Telephone Fax In Person 0 REMARKS: ---\JN~Ail..A15 Lb By: Morteza Beheshti EsGil 9/7 Enclosures: 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 Carlsbad CBC2018-0507 9/17/2018 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK#.: CBC2018-0507 OCCUPANCY: U TYPE OF CONSTRUCTION: NA ALLOWABLE FLOOR AREA: SPRINKLERS?: REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 11/6/17 DATE INITIAL PLAN REVIEW COMPLETED: 9/17/2018 FOREWORD (PLEASE READ): JURISDICTION: Carlsbad USE: Parking Garage ACTUAL AREA: 209,524 STORIES: 1 HEIGHT: OCCUPANT LOAD: DA TE PLANS RECEIVED BY ESGIL CORPORATION: 9/7 PLAN REVIEWER: Morteza Bebeshti This plan review is limited to the technical requirements contained in the California version of the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 2016 CBC, which adopts the 2015 IBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2015 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list {or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad CBC2018-0507 • 9/17/2018 [DO NOT PAY-THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PREPARED BY: Morteza Beheshtl PLAN CHECK#.: CBC2018-0507 DATE: 9/17/2018 BUILDING ADDRESS: 2456 Town Garden Road BUILDING OCCUPANCY: B BUILDING AREA Valuation PORTION ( Sq. Ft.) Multiplier 17 EV CharQer install TOTAL VALUE Jurisdiction Code CB By Ordinance 1997 use Building Permit Fee • ··--····-· 1997 USC Plan Check Fee • Type of Review: 0 Complete Review D Repetitive Fee -----~, Repeats Comments: □ Other 0 Hourly EsGil Fee Reg. Mod. VALUE ($) 150,000 150,000 $803.561 $522.31 I O Structural Only $458.031 Sheet 1 of 1 Carlsbad CBC2018-0507 9/17/2018 Please make all corrections on the original tracings, as requested in the correction list. Submit two sets of plans to the City of Carlsbad Building Department Or EsGil Corporation. ELECTRICAL, and ENERGY COMMENTS PLAN REVIEWER: Morteza Beheshti ELECTRICAL (CALIFORNIA ELECTRICAL CODE) 1. Provide a single line diagram for the new service. Include the following information: • Indicate the ground electrode type for the 225 KVA transformer. • Specify whether the system design is fully-rated, series rated, or engineered (fault current levels shown throughout the system). 2. Out swinging door(s) equipped with panic hardware is required for doors accessing rooms containing electrical equipment rated BOO amperes or more. CEC110.26(C)(3). 3. Emergency illumination is required to be installed in electrical equipment rooms. Please provide. CBC 1008.3.3 4. Please include brochure cuts of the chargers. 5. Please include installation method for the EV1 chargers. Demonstrate physical protection is provided from vehicles. 6. At least (1) convenience receptacle outlet shall be installed within 50' of the electrical service (Does not apply to one and two family residential occupancies). CEC 210.64 7. Electric Vehicle Charging for the ADA parking van accessible must comply with CBC Table 11 B-228.3.2.1 To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes □ No □ Carlsbad CBC2018-0507 9/17/2018 The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Morteza Beheshti at Esgil Corporation. Thank you. SAN DIEGO 858-638-0600 858-638-0640 FAX 4115 Sorrento Valley Blvd. San Diego, CA 92121 IRVINE 949---864-0600 949-864-0640 FAX 5251 California Suite 110 Irvine, CA 92617 www.mwalleng.com MICHAEL WALL ENGINEERING NOV O 5 2018 -\: Sep. 18, 2018 Morteza Beheshti EsGil Corporation 9320 Chesapeake Drive, Suite 208 San Diego, CA 92123 Re: Install 17 Electric Vehicle Chargers for Viasat Plan Check#: CBC2018-0507 MWE Job No. 16-190 We have received the comments from your plan review for the above referenced project. We have responded to each Issue (in italics), and have included the original Issues (in boldface} for your reference. Electrical: D 1. Provide a single line diagram for new service. Include the following information: • Indicate the ground electrode type for 225KVA transformer. • Specify whether the system design is fully-rated, series rated, or engineered (fault current levels shown throughout the system) Response: See sheet E2. 1 for singleline diagram indicating wat is new and what is existing. Also see singleline diagram for grounding conductor for new transformer T-EV1. The system is and engineered system. See fault current values for new equipment on singleline diagram. D 2. Out swinging door(s) equipped with panic hardware is required for doors accessing rooms containing electrical equipment rated 800 amperes or more. CEC110.26(C)(3). Response: See architectural plans for panic hardware. See attached sheet A4.03 □ 3. Emergency illumination is required to be installed in electrical equipment rooms. Please provide. CBC 1008.3.3. Response: Lighting in the main electrical room is existing and connected to the existing emergency lighting inverter. □ 4. Please include brochure cuts of the chargers. Response: For brochure for EV chargers, refer to separate pdf cut sheet model CT4023 with highlighted options. MICHAEL WALL ENGINEERING □ 5. Please include installation method for the EV1 chargers. Demonstrate physical protection is provided from vehicles. Response: Refer to architectural drawings for physical protection from vehicles. See details 5 and 12 on attached sheet A4.03 □ 6. At least 11) convenience receptacle outlet shall installed within 50' of the electrical service (Does not apply to one and two family residential occupancies). Response: For existing convenience receptacle located in the Electrical room, refer to sheet E4. 1 Enlarged Plans & Details □ 7. At Electric Vehicle Charging for ADA parking van accessible must comply with CBC Table 118-228.3.2.1. Response: Two EV locations are shown on sheet E1.3B for ADA parking van accessible compliance. We trust that these responses, along with the corrections to the plans, meet with your approval. Should you have any questions or comments, please feel free to contact me at 858-638-0600. Sincerely, Ray Thompson Sr. Project Engineer Michael Wall Engineering, Inc. \., -charge poin+ CT4000 Level 2 Commercial Charging Stations Specifications and Ordering Information Ordering Information Specify model number followed by the applicable code(s). The order code sequence is: Model-Options. Software. Services and Misc are ordered as separate line items. Hardware Description Order Code Model 1830 mm (6') Single Port Bollard Mount CT4011 1830 mm (6') Dual Port Bollard Mount CT4021 1830 mm (§') Single Port Wall Mount CT4013 1830 mm (6') Dual Port Wall Mount CT4023 2440 mm (8') Dual Port Bollard Mount CT4025 2440 mm (8') Dual Port Wall Mount CT4027 Options Integral Gateway Modem -USA -GWl Integral Gateway Modem -Canada -GW2 Misc Power Management Kit CT 4000-PMGMT Bollard Concrete Mounting Kit CT4001-CCM Software & Services Description Order Code ChargePoint Commercial Service Plan ChargePoint Service Provider Plan ChargePoint Assure Station Activation and Configuration ChargePoint Station Installation and Validation CTSW-SAS-COMM-n1 CTSW-SAS-SP-n' CT 4000-ASSUREd CPSUPPORT-ACTIVE CT 4000-INSTALLVALID Note: All CT 4000 stations come with 1 year of ChargePoint Assure coverage at no charge for qualified installations. Other conditions apply. All CT 4000 stations require a network service plan. 1 Substitute n for desired years of service (1, 2. 3. 4, or 5 years). • Substitute n for the duration of the additional coverage (1. 2, 3, or 4 years). Order Code Examples If ordering this the order code is 1830 mm (6') Dual Port Bollard USA Gateway Station CT4021-GW1 with Concrete Mounting Kit CT 4001-CCM ChargePoint Commercial Service Plan, CTSW-SAS-COMM-3 3 Year Subscription ChargePoint Station Installation and Validation CT4000-INSTALLVAUD 2 Additional Years of Assure Coverage CT4000-ASSURE2 1830 mm (6') Single Port Wall Mount Station CT4013 ChargePoint Commercial Service Plan. S Year Subscription 4 Additional Years of Assure Coverage Station Activation and Configuration CTSW-SAS-COMM-5 CT 4000-ASSURE4 CPSUPPORT-ACTIVE CT4021 ,. Ch~Point CT 4000 Family CT 4021 1830 mm (6') CT 4025 2440 mm (8') Bollard 347mm ~ (13.7") +- CT4025 2426 mm (95.5") CT4021 1811 mm (71.3") 2 chargepoint.com 233mm (9.2") 1186 mm (46.7") J i 470mm (18.5") CT 4023 1830 mm (6') CT 4027 2440 mm (8') Wall Mount CT4027 2426 mm (95.5") 347mm ---+ (13.7") CT4023 1811 mm (71.3") l 302mm (11.9") ~ 233mm (9.2") 1184 mm (46.6") _l i 483mm (19.0")