Loading...
HomeMy WebLinkAboutFPC2022-0159; 2470 FARADAY AVEPERMIT REPORT Fire Permit Print Date: 10/18/2023 Job Address: Permit Type: Parcel#: Valuation: Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Project Title: 2470 FARADAY AVE, CARLSBAD, CA 92010-7224 FIRE-Construction Commercial Work Class: 2090412600 Track#: $0.00 Lot#: Project#: Plan#: Construction Type: Orig. Plan Check#: Plan Check#: Fire Alarm (city of Carlsbad Permit No: FPC2022-0159 Status: Closed -Finaled Applied: 08/30/2022 Issued: 09/27/2022 Finaled Close Out: 05/09/2023 Final Inspection: INSPECTOR: Cheung, Nathaniel Description: SCIEX 2 (BECKMAN COULTER) -ADD 1 DUCT SMOKE DETECTOR & 1 SMOKE HEAT DETECTOR -CONNECT TO EXISTING FIRE PAI Applicant: SECURITAS TECHNOLOGY STANLEY SECURITY SCOTT HAIN ES 13034 CREE DR POWAY, CA 92064-3815 (858) 276-9742 FEE FIRE Tl Fire Alarm System Total Fees: $735.00 Total Payments To Date: $735.00 FPContractor: STANLEY SECURITY 9240 TRADE PL, # STE 300 SAN DIEGO, CA 92126-6314 (858) 752-1775 Balance Due: AMOUNT $735.00 $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 442-339-2665 I Inspections: 442-339-2660 I www.carlsbadca.gov (2) F1re·L11e· Alarms www.firelite.com GENERAL The Fire•Lite Alarms 5D355 and SD355T addressable, low-profile plug-in photoelectric detectors use a state-of- the-art photoelectric sensing chamber with communica- tions to provide open area protection and are used exclu- sively with Fire•Lite's MS-9200, MS-9200UD, and MS-9600 Addressable Fire Alarm Control Panels (FACPs). The SD355T adds thermal sensors that will alarm at a fixed temperature of 135°F (57°C)' Since these detectors are addressable, they will help emergency personnel quickly locate a fire during its early stages, potentially saving pre- cious rescue time while also reducing property damage Two LEDs on each sensor light to provide a local, visible sensor indication. Remote LED annunciator capability is available as an optional accessory (P/N RA400Z) FEATURES SLC/oop: • Two-wire loop connection. • Unit uses base for wiring. detector head plugs-in. Addressing: Addressable by device. • D,rect Decade 01 -99 (MS-9200, MS-9200UD) and 01 -159 (MS-9600) entry of address. Architecture: Unique single-source, dual-chamber design to respond quickly and dependably to a broad range of fires Sleek, low-profile design. Integral communications and built-in type identification. Built-in tamper-resistant feature Removable cover and insect-resistant screen for simple field cleaning. Operation: Withstands air velocities up to 1,500 feet-per-minute (7 6 m/sec.) without triggering a false alarm. Factory preset at 1.5% nominal sensitivity for panel alarm threshold level. Visible LED "blinks" when the unit is addressed (com- municating with the fire panel) and latches on in alarm. Mechanicals: Sealed against back pressure Direct surface mounting or electrical box mounting. Mounts to: single-gang box, 35" (8.89 cm) or 4.0" (10.16 cm) octagonal box, or 4.0" (10.16 cm) square electrical box (using a plaster ring -included). Fire•Lite® Alarms is a Honeywell company July 14, 2004 DF-52384 • E-160 SD355(A)/ SD355T(A) Addressable Photoelectrlc Smoke Detectors Section: Addressable Devices ®~ LISTED S1059 MEA 5D355 with srn,,o,~ SD355T with • B350LP base '"" Other system features: California State Fire Marshal 7272-0075 194 <8> APPROVED Fully coated circuit boards and superior RF/transient pro- tection. 94-V0 plastic flammability rating Low standby current Options: • Remote LED output connection (PIN RA400Z) APPLICATIONS Use photoelectric detectors in life-safety applications to pro- vide a broad range of fire-sensing capability, especially where smoldering fires are anticipated. Ionization detec- tors are often better than photoelectric detectors at sens- ing fast, flaming fires. This document is not intended to be used tor installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. ISO 9001 CERTIFIED ENIINIIIING I MANUIIICTIIIING QUALITY SYSTEMS For more information, contact Fire•Lite Alarms, One Fire-Lite Place, Northford, Connecticut 06472. Phone: (800) 627-3473, Toll-Free FAX: (877) 699-4105 OF-52384 • 07/14104 -Page 1 of 2 CONSTRUCTION These detectors are constructed of off-white LEXAN®. SD355(T) plug-in, low-profile smoke detectors are designed to commercial standards and offer an attractive appear- ance LEXAN® is a registered trademark of GE Plastics, a subsidiary of General Electric Company. INSTALLATION SD350(T) plug-in detectors use a detachable mounting base to simplify installation, service and maintenance. Mount base on box which is at least 1.5 inches (3.81 cm) deep. Suitable boxes include: 4.0" (10 16 cm) square box with plaster ring. 4.0" (10 16 cm) octagonal box 3.5" (8 89 cm) octagonal box Single-gang box. NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring "T-taps" or branches are permitted for Style 4 (Class BJ wiring only OPERATION Each SD355(T) uses one of 99 possible addresses on the MS-9200 and MS-9200UD Signaling Line Circuit (SLC), or up to 318 (159 on each loop) on the MS-9600 SLC. It re- sponds to regular polls from the system and reports its type and status. The SD355(T) addressable photoelectric sensor's unique unipolar chamber responds quickly and uniformly to a broad range of smoke conditions and can withstand wind gusts up to 1,500 feet-per-minute (7.6 m/sec.) without sending an alarm level signal. Because of its unipolar chamber, the SD355(T) is approximately two times more responsive than most photoelectric sensors. This makes it a more stable detector. DETECTOR SENSITIVITY TEST Each detector can have their sensitivity tested (required per NFPA 72, Chapter 7 on Inspection, Tes/mg and Main- tenance) when installed/connected to an MS-9200, MS- 9200UD, or MS-9600 addressable fire alarm control panel The results of the sensitivity test can be printed off the MS- 9200, MS-9200UD, or MS-9600 for record keeping. SPECIFICATIONS Voltage range: 15 -32 voe (peak). Standby current: 300 µA@ 24 voe. LED current: 6.5 mA@ 24 VDC (latched "ON") Air velocity: 1,500 ft/min. (7.6 m/sec.) maximum. Diameter: 6.1" (15.5 cm) installed in B350LP base Height: 2.1" (5.33 cm) installed in B350LP base. Weight: 3.6 oz. (102 g). Operating temperature range: for SD355: O'C to 49'C (32°F to 120'F) SD350; for SD355T: O'C to 38'C (32'F to 1 OO'F). Temperature: O'C -49'C (32'F -120'F) Relative humidity: 10% -93%, non-condensing Page 2 of 2 ~ DF-52384 • 07/14/04 PRODUCT LINE INFORMATION NOTE: "A" suffix indicates ULC-Listed model. S0355 Addressable photoelectric detector (8350LP base included) S0355A Same as S0355 with ULC Listing (8350LPA base included). SD355T Same as S0355 but with thermal element (8350LP base included). S0355TA Same as SD355T with ULC Listing (8350LPA base included). RA400Z(A) Remote LED Mounts to a single-gang box. B350LP(A) Plug-in detector base (included). Dimen- sions: 6.1" (15.5 cm). Mounting:4.0" (10.16 cm) square box with or without plastic ring, 4.0" (10.16 cm) octagonal box, 3.5" (8 89 cm) octagonal box, or single-gang box. All mount- ing boxes have a minimum depth of 1.5" (3 81 cm) B224RB(A) Plug-in System Sensor relay detector base. Diameter: 6.2" (15.75 cm). Mounting: 4.0" (10.16 cm) square box with or without plastic ring, 4.0" (10 16 cm) octagonal box, or 3.5" (8 89 cm) octagonal box. All mounting boxes have a minimum depth of 1.5" (3 81 cm) B224BI(A) Intelligent isolator base, isolator SLC from shorts on the loop B501BH(A) Plug-in System Sensor sounder detector base. Diameter: 6.0" (15.24 cm). Mounting: 4.0" (10.16 cm) square box with or without plastic ring. Mounting box has a minimum depth of 1.5" (3 81 cm). B501BHT(A) Same as B501BBH(A), but includes tempo- ral sounder. Accessories: RA400Z(A) Remote LED annunciator. 3 -32 VDC. Fits U.S. single-gang electrical box. For use with 8501 (A) and 8350LP(A) bases only. SMK400 Surface mounting kit provides for entry of surface wiring conduit For use with 8501(A) base only. RMK400 Recessed mounting kit For use with 8501 (A) base only. M02-04-01 Test magnet XR-2 Detector removal tool. Allows installation and/ or removal of detector heads from bases in high ceiling applications. XP-4 Extension pole for XR-2. Comes in three 5-ft. (1 524 m) sections. ~SYSTEM '--~ SENSOR. Duct Smoke Detector Accessories Expand the versatility of the lnnovairFlex" line of duct smoke detectors with System Sensor notification and test accessories. Available Accessories APA151 MHR MHW RA 100Z/RA 100ZA RTS151 RTS151KEY RTS2 ADS RTS2-AOS Piezo Annunciator Mini-Horn, Red Mini-Horn. White Remote Annunciator Remote Test Station Remote Test Station with Key Mult1-S1gnal1ng Accessory Add-On Strobe Mult1-S1gnal1ng Accessory Agency Listings @ LISTED <8> APJ'ROVED Duct smoke detector accessories add functionality to the duct smoke detection system by allowing quick, convenient inspections at eye level and effective audible and v1s1ble notification options. All System Sensor duct smoke detectors and accessories are UL listed The APA151 pIezo annunciator. which replaces the APA451 with a new. improved look, provides an audible alarm signal. a red LED to indicate alarm status. and a green LED to indicate power status It Is intended for use with System Sensor 4-wire conventional duct smoke detector applications without a system control panel to comply with NFPA 90A The MHR and MHW SpectrAlerr·, Advance mini-horns feature temporal or continuous tones at high and low volume settings n1eir small footprint allows mounting to single-gang back boxes for applications wl1ere a small device is desired The RA100Z and RA100ZA remote annunciators are designed for both conventional and intelligent applications Their red LED provides visual indication oi an alarm condition The RTS151 and RTS151KEY remote test stations are automatic fire detector accessories designed to test duct smoke detectors from a convenient location. For 4-wire detectors, the RTS151 KEY test station features a multi-colored LED that alternates between steady green and red For 2-wire detectors, the LED illuminates red for alarm The RTS2 and RTS2-AOS multi-signaling accessories are designed to work with lnnova1rFlex 4-wire conventional duct smoke detectors These accessories include a key switch that can be used to select one ot two connected sensors to be tested. reset. or both by a push button switch They also enable sensitivity measurements using the SENS-RDR sensitivity reader (sold separately). The AOS (Add-On Strobe) is an optional accessory included with the RTS2- AOS model Specifications, Duct Smoke Detector Accessories APA151 Piezo Annunciator Voltage Regulated 24 voe Operating Voltage 16 to 33 voe Maximum Alarm Current 30mA Temperature Range O"C to 49°e (32'F to 120"F) Relative Humidity 1 Oto 93°/c, non-condensing Wire Gauge 12 to 18 AWG Dimensions 4 6"H x 2.9"W x .45"0 MHR/MHW SpectrAlerf2' Advance Mini-Horns Voltage Sounder Current Draw Temperature Range Humidity Range Nominal Sounder Frequency Wire Gauge Dimensions Regulated 12 DC or FWR (Full Wave Rect1f1ed) or Regulated 24 voe or FWR 22 mA RMS max. at 8 to 17 .5 Volts DC 29 mA RMS max. at 16 to 33 Volts DC O"e to 49 •e (32' F to 120"F) 10 to 93% non-condensing 3 kHz 12 to 18 AWG 46"Hx29"'Wx045 D RA100Z/RA100ZA Remote Annunciator Voltage Range Maximum Alarm Current Dimensions RTS151 UL S4011 RA 1002 UL S2522 Conventional System. 3 1 to 32 VDC Intelligent System rn to 32 voe 10mA 46 "Hx28"Wx 1.3"0 RTS151KEY UL S2522 MHW UL S4011 RTS151 Remote Test Station Power Requirements Test Switch Reset Switch Alarm Response Time Temperature Range Relative Humidity Wire Gauge Dimensions Alarm LED: 2.8 to 32 VDC, 12 mA max Total Current: 105 mA max 10 VA@32 voe 10VA@32VOe 40 seconds max -10'e to 60°e (WF to 140"F) 95% non-condensing 14 to 18 AWG 48Hx2.90'Wx14'0 RTS151KEY Remote Test Station with Key Power Requirements Alarm Response Time Temperature Range Relative Humidity Wire Gauge Dimensions Power LED (Green): 14 to 35 voe, 12 mA max. Alarm LED (Red) 2 8 to 32 VDC 12 mA max Total Current: I 05 mA max 40 seconds max 95% non-condensing 14 to 18 AWG 4.6Hx2.75'Wx1.8'0 RTS2 and RTS2-AOS Multi-signaling Accessory Voltage Power Requirements Sounder Temperature Range Relative Humidity Wire Gauge 20 to 29 voe Standby: 3 O mA max Trouble. 16 O mA max Alarm without strobe: 30 mA max Alarm with strobe: 55 mA max 85 dBA at ten feet -100 to so•c (14"F to 140'FI 95% non-condensing 14 to 22 AWG Dimensions 4.S'"W x 5.3"H x 1 6"'0 For the very latest product specifications and listing information. please visit the System Sensor Web site at www.systemsensor.com --__; --~ .....-·-.- APA151 UL S4011 RTS2-AOS UL S2522 MHR UL S4011 AOS ~~SYSTEM C~ SENSOR 3825 Ohio Avenue• St Charles. IL 60174 Phone 800-SENSOR2 • Fax 630-377-6495 www systemsensor.com ,., j, • ,,,I •' 11 ,r " l,W MMF-300(A) Series, MDF-300 Addressable Monitor Modules General Four different monitor modules are available for Fire•Lite's intelligent control panels to suit a variety of applications. Moni- tor modules are used to supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (MMF-302(A)). MMF-300(A) is a standard-sized module (typically mounts to a 4" [10.16 cm] square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input devices. MMF-301(A) is a miniature monitor module a mere 1.3" (3.302 cm) H x 2. 75" (6.985 cm) W x 0.65" (1.651 cm) D that super- vises a Style B (Class B) circuit of dry-contact input devices. Its compact design allows the MMF-301(A) to be mounted in a single-gang box behind the device it monitors. MMF-302(A) is a standard-sized module used to monitor and supervise compatible two-wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit MDF-300(A) is a standard-sized dual monitor module used to monitor and supervise two independent two-wire Style B (Class B) dry-contact initiating device circuits (IDCs) at two separate, consecutive addresses in intelligent, two-wire sys- tems. LiteSpeed™ ls a communication protocol developed by Fire•Lite Engineering that greatly increases the speed of com- munication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other communication protocols. MMF-300(A) Monitor Module Built-in type identification automatically identifies this device as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 -159 on MS-9600 series panels, 01 -99 on other compatible systems. LEO flashes during normal operation and latches on steady to indicate alarm. The MMF-300(A) Monitor Module is intended for use in intelli- gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (IDC) for nonmally-open-contact fire alanm and supervisory devices. The module has a panel-controlled LED indicator. The MMF-300(A) can be used to replace M300(A) modules in existing systems. MMF-300(A) APPLJCATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special DF-52121:E • E-325 @) Flre·LITe'ALarms by Honeywell Addressable Devices MMF-300(A) (Type H) supervisory indication at the control panel. Monitored circuit may ba wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circurt. A 47K Ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. MMF-300(A) OPERATION Each MMF-300(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alanm (subject to current limitations on the loop). MMF-300(A) SPECIRCATIONS Nominal operating voltage: 15 to 32 voe. Maximum current draw: 5.0 mA (LED on). Average operating current: 375 µA (LED flashing), 1 com- munication every 5 seconds, 47k EOL. Maximum IDC wiring resistance: 1500 Ohms. Maximum IDC Voltage: 11 Volts. EOL resistance: 47K Ohms. Temperature range: 32'F to 120"F (0'C to 49'C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. MMF-301(A) Mini Monitor Module Built-in type identification automatically identifies this device as a monitor module to the panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. DF-52121:E•07/30/2015-Page 1 of4 Tinned, stripped leads for ease of wiring. Direct-dial entry of address: 01 -159 on MS-9600 series panels, 01 -99 on other compatible systems 1~1@4 150 12 ADDRESS ~: ~~ @ ; LOOP 10 5 D 9 8 7 6 9 8 7 6 TENS ONES ~ ~ ~ ~ ~ The MMF-301 (A) Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The MMF-301 (A) is intended for use in intelligent, two-wire systems where the individual address of each module is selected using rotary switches. It provides a two-wire initiat- ing device circuit for normally-open-contact fire alarm devices. The MMF-301(A) can be used to replace M301(A) modules in existing systems. MMF-301(A) APPLJCAn0NS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit/ device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor (provided) terminates the circuit. MMF-301(A) OPERAn0N Each MMF-301(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initialing Device Circuit (IDC). MMF-301(A) SPECIRCATIONS Nominal operating voltage: 15 to 32 VDC. Average operating current: 350 µA, 1 communication every 5 seconds, 47k EOL; 600 µA Max. (Communicating, IDC Shorted). Maximum IDC wiring resistance: 1500 Ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 450 µA. EOL resistance: 47K Ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3" (3.302 cm) high x 2.75" (6.985 cm) wide x 0.65" (1.651 cm) deep. Wire length: 6" (15.24 cm) minimum. MMF-302(A) Interface Module • Supports compatible two-wire smoke detectors. Page 2 of 4 -DF-52121 :E • 07/30/2015 Supervises IDC wiring and connection of external power source. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry entry of address: 01 -159 on MS-9600 series panels, 01 -99 on other compatible systems. LED flashes during normal operation. LED latches steady to indicate alarm on command from control panel. The MMF-302(A) Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (normal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being monitored must be UL compatible with the module. The MMF-302(A) can be used to replace M302(A) modules in existing systems. MMF-302 (A) APPLICAnONS Use the MMF-302(A) to monitor a zone of two-wire smoke detectors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 3.9 K Ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resistance is 25 Ohms). Install ELR across terminals 8 and 9 for Style D application. MMF-302(A) OPERAn0N Each MMF-302(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alamn (subject to current limitations on the loop). MMF-302(A) SPECIRCAnONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 Ohms. Average operating current: 270 µA, 1 communication and 1 LED flash every 5 seconds, 3.9k eel. EOL resistance: 3.9K Ohms. External supply voltage (between Terminals T10 and T11): DC voltage: 24 volts power limited. • Ripple voltage: 0.1 Vmns maximum. • Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. MDF-300(A) Dual Monitor Module The MDF-300(A) Dual Monitor Module is intended for use in intelligent, two-wire systems. It provides two independent two- wire initiating device circuits (IOCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices. The module has a single panel- controlled LED. NOTE: The MDF-300(A) provides two Style B (Class BJ /DC cir- cuits ONLY. Style D (Class A) /DC circuits are NOT supported in any application. MDF-300(A) SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Average operating current: 750 µA (LED flashing). Maximum JDC wiring resistance: 1,500 Ohms. Maximum JDC Voltage: 11 Volts. Maximum JDC Current: 240 µA EOL resistance: 47K Ohms. Temperature range: 32° to 120°F (0° to 49°C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. MDF-300(A) AUTOMATIC ADDRESSING The MDF-300(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the MDF-300(A) is set to address "26", then it will automati- cally assign itself to addresses "26" and "27". NOTE: "Ones" addresses on the MDF-300(A) are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. CAUTION: Avoid duplicating addresses on the system. Installation MMF-300(A), MMF-302(A), and MDF-300(A) modules mount directly to a standard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and installa- tion instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regu- lations. These modules are intended for power-limited wiring only. The MMF-301 (A) module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S2424. ULC: S2424. FM Approved, CSFM: 7300-0075:0185. MEA: 72-01-E. Product Line Information NOTE: "A" suffix indicates ULC-/isted model. MMF-300(A): Monitor module. MMF-301(A): Monitor module, miniature. MMF-302(A): Monitor module, two-wire detectors. MDF-300(A): Monitor module, dual, two independent Class B circuits. SMBS00: Optional surface-mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN 51309. Architects'/Englneers' Specifications Specifications of these devices and all Firelite products are available from Firelite. OF-52121 :E • 07/30/2015 -Page 3 of 4 • ISO 9001 19ii-S ◄IWl¥i-■ 1111111111!1 1 IIIIIRIIUNG IIAIITY SYSTl ■s Fire-Lite® is a registered trademark and LiteSpeed™ and FireWatch™ are trademarks of Honeywell International Inc. C2015 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. we try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Fire•Lite Alarms. Phone: (600) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 4 of 4-DF-52121:E • 07/30/2015