Loading...
HomeMy WebLinkAbout1999-08-04; Planning Commission; ; CT 99-07|CP 99-09|HDP 99-05 - LA COSTA FAIRWAY VILLASV,fhe City of CARLSBAD Planning DepartmtTi A REPORT TO THE PLANNING COMMISSION Item No. P.C. AGENDA OF: August 4, 1999 Application complete date: May 5, 1999 Project Planner: Barbara Kennedy Project Engineer: Clyde Wickham SUBJECT: CT 99-07/CP 99-09/HDP 99-05 - LA COSTA FAIRWAY VILLAS - Request for approval of a Mitigated Negative Declaration, Mitigation Monitoring and Reporting Program, Tentative Tract Map, Condominium Permit, and Hillside Development Permit to create a 16-unit condominium project located on the south side of Gibraltar Street near the intersection of Jerez Court in the RD-M zone and Local Facilities Management Zone 6. I. RECOMMENDATION That the Planning Commission ADOPT Planning Commission Resolution No. 4595 APPROVING a Mitigated Negative Declaration and Mitigation Monitoring and Reporting Program, and ADOPT Planning Commission Resolutions No. 4596, 4597, and 4598 APPROVING CT 99-07, CP 99-09, and HDP 99-05, based on the findings and subject to the conditions contained therein. II.INTRODUCTION The applicant is requesting approval of a single-lot tentative tract map, condominium permit, and hillside development permit to allow the grading of a 1.18 acre site and construction of a 16-unit airspace condominium project consisting of two- and three-unit attached homes. As designed and conditioned, the project is in compliance with the General Plan, Subdivision Ordinance, and relevant zoning regulations of the Carlsbad Municipal Code. III. PROJECT DESCRIPTION AND BACKGROUND The 1.18 acre site currently consists of 3 separate lots and is located south of Gibraltar Street near the intersection of Jerez Court. The lots have been previously graded and are terraced downhill (west to east) with slopes of 10 to 12 feet between pads. A 11/2:1 slope along the rear property line slopes up to the south approximately 40 feet. The proposed site design will result in the creation of two pads separated by a 15 foot grade differential with half of the residences on each level. Each pad area will be accessed by separate 30 foot wide driveways that intersect with Gibraltar Street. The project proposes grading a majority of the site with portions of the rear slope left undisturbed. The grading operations will result in a balanced grading operation with approximately 3,000 cu. yds. of cut and 3,000 cu. yds of fill. Retaining walls will be located at the south and west ends of the site in order to create a level area for private open space. None of the walls will exceed 6 feet in height and the project will be fully landscaped for site beautification and erosion control. CT 99-07/CP 99-09/HDP-05 - LA COSTA FAIRWAY August 4, 1999 Page 2 As shown on Exhibits "F" - "M", the layout and floor plans of the individual units vary based on their location on the site and, in general, consist of split level three-story structures. Two groups of tri-plex residences are located along Gibraltar Street with driveway entrances on both the east and west ends of the site. Duplex and tri-plex structures are also located along the sides and rear of the site and are clustered along the driveway. The square footage of the three and four bedroom units range from 2,013 square feet to 2,471 square feet. Each unit features a private rear yard and/or balcony and each unit has an attached two-car garage. The units have been designed in a contemporary architectural style with stucco exterior and tile roofs. Two large open space areas are provided at each end of the site. The eastern site is designed as an active open space with barbecue facilities and a spa; and the open space on the west end is designed as a children's play area. The design concept has taken into consideration hillside conditions and has been designed to provide private "exclusive use rear yards" for nearly all of the units. A total of seven (7) guest parking spaces are required and are provided in convenient locations throughout the site. In addition, a 494 square foot RV parking and storage area is provided near the center of the site. The property is Zoned Residential Density-Multiple (RD-M) and has a General Plan Land Use Designation of Residential High (RH 15-23 du/ac) with a Local Facilities Growth Management Control Point of 19 dwelling units per acre. The proposed 16-unit condominium project results in a density of 13.5 dwelling units per acre. The proposed development is consistent with the surrounding land uses which consist of two - and three-story multi-family apartment and condominium projects. On April 9, 1992, a similar proposal was approved for 16 condominium units on the subject property (CT 91-15/CP 91-03/HDP 91-10). However, the previous owner never constructed the project and the project approvals expired. The project is subject to the following land use plans, policies, programs, and zoning regulations: A. General Plan B. Chapter 21.45 - Planned Development Ordinance C. Chapter 21.95 - Hillside Development Ordinance D. Carlsbad Municipal Code, Title 20 (Subdivision Ordinance) E. Chapter 21.85- Inclusionary Housing Ordinance F. Growth Management (Local Facilities Management Zone 6) IV. ANALYSIS The recommendation of approval for this project was developed by analyzing the project's consistency with the applicable policies and regulations listed above. The following analysis CT 99-07/CP 99-09/HDP 59-05 - LA COSTA FAIRWAY VILLAS" August 4, 1999 Page 3 section discusses compliance with each of these policies/regulations utilizing both text and tables. A. General Plan The Land Use Element of the General Plan characterizes Residential High Density (RH) as low and medium rise condominium and apartment development. The General Plan Growth Management Control Point is 19 units per acre and the proposed density is 13.5 units per acre. The residential guidelines encourage a variety of housing types; limit higher density residential developments to those areas where they are compatible with adjacent land uses; and encourage the achievement of a variety and choice of housing in all economic ranges throughout the City. The adjacent development and surrounding neighborhood consists of two- and three-story multi- family projects. Similarly, the proposed project offers a higher density housing type; is compatible with adjacent development in density, scale, and mass; and can therefore be found to be consistent with the goals of the General Plan. The project is consistent with the Housing Element in that inclusionary housing requirements for the project will be satisfied through the purchase of 2.8 affordable housing credits within the Villa Loma project. B. Planned Development Ordinance Approval of the Condominium Permit is subject to compliance with the Planned Development section of the Zoning Ordinance. The proposal complies with setback, and height regulations. The proposal provides sufficient parking for residents and guests, individual interior storage, and common recreational vehicle storage. Open space requirements are satisfied through the provision of exterior balconies, private rear yards, and common recreation spaces including active areas for both adults and children. Coast Waste Management Service has indicated by letter that the project provides adequate access and space for collection of trash and recyclables. The proposed project is subject to and consistent with the following Planned Development Ordinance development standards: STANDARD Density/Product Type Minimum lot size Arterial Setbacks Setbacks: Front Rear Side Distance Between Structures Building Height Private driveway width Recreational space Private: REQUIRED 19 du/ac N/A N/A 10' 10' 5' 10' 35' Maximum 30' Minimum 200 s.f./unit or 3,200 s.f. lOOs.f./unit PROVIDED 13.5 du/ac attached condominiums air space ownership N/A 10' 20' 5' 10' 35' 30' Min. 15' x 15' private rear yards and/or balconies CT 99-07/CP 99-09/HDP August 4, 1999 Page 4 1V-05 - LA COSTA FAIRWAY VILLASs Common: RV Storage Resident Parking Visitor Parking Storage Active 1,600 s.f. min. 320 sq. ft. 2 covered spaces/unit 7 spaces 392 cu. ft. 5,272 s.f. including barbecue, spa, children's play area. 494 sq. ft. 2 car garage/unit 7 spaces 392 cu. ft. within garage C. Hillside Development Ordinance A Hillside Development Permit is required to be processed along with the request for approval of any development on properties which have slopes greater than 15% and an elevational difference of 15 feet or more. The site has been graded by previous approval (approved as La Costa South #5 in 1969) into three pads, each separated by approximately a 10 foot elevational difference. This pre-graded condition creates significant constraints for designing a circulation system within the site which complies with the maximum gradients allowed by engineering design standards. In order to create a project that complies with engineering standards and better relates to the site's topography, the applicant is proposing to regrade the site into two larger pads, separated by a 15 foot elevation difference. In accordance with hillside regulations, the areas of 40% slope which were created by the previously approved grading are identified. The proposal requires a modification to the hillside development standards to allow an encroachment over 6 feet high into the toe of the uphill perimeter slope. Findings for the proposed modification can be made in that the development into the existing manufactured slopes will result in a superior site design, will allow for the provision of private rear yards for residences abutting the slope, and will result in additional common active open space areas. The proposed site design utilizes split-level building pads to reduce the quantities of cut and fill. Maximum 6 foot high retaining walls are located at the rear of the south and west buildings so that private rear yards can be provided for these units. The proposed balanced grading will consist of approximately 3,000 cubic yards of cut and 3,000 cubic yards of fill which results in a volume of 2,542 cubic yards per acre. This volume falls within the Hillside development Ordinance acceptable range of 0-7,999 cubic yards per acre. Because this project will have no control on the upper portion of the llA:l rear slope, a special condition has been included for the project developer and owner to execute a Hold Harmless Geologic Failure Agreement. The slope is shared by the project and the adjacent property owner. D. Subdivision Ordinance The proposed tentative map complies with all applicable requirements of the City's Subdivision Ordinance. The Subdivision Map Act allows for merger of the three existing lots and subsequent resubdivision into 16 airspace condominiums on one common lot. The site is served by existing public streets and utilities, and the project is conditioned to construct all necessary private driveway and utility improvements to serve the proposed units. Access to the site is via two points on Gibraltar Street: an access driveway at the upper west end of the site and access at the lower east end of the site. The subdivision design orients structures in an east-west alignment and takes advantage of shade and prevailing breezes. C 3CT 99-07/CP 99-09/HDP 9^-05 - LA COSTA FAIRWAY VILLAS* August 4, 1999 Page 5 £. Inclusionary Housing Ordinance The City's Inclusionary Housing Ordinance (Chapter 21.85) requires that a minimum of 15% of all approved units in any qualified residential subdivision be made affordable to lower income households. The inclusionary housing requirement for this project would be 2.8 dwelling units. The applicant is proposing to satisfy this requirement by purchasing affordable housing credits. The project has been conditioned to enter into an Affordable Housing Agreement with the City to purchase and deed restrict 2.8 units in the Villa Loma Apartment Project as affordable to lower- income households for the useful life of the dwelling units, in accordance with the requirements set forth in Chapter 21.85 of the Carlsbad Municipal Code. Therefore, with this condition in place, the proposed project complies with all applicable inclusionary housing requirements. F. Growth Management The proposed project is located within Local Facilities Management Zone 6 in the southeast quadrant of the City. The impacts on public facilities created by the project, and its compliance with the adopted performance standards, are summarized in the table below. City Administration Library Waste Water Treatment Parks Drainage Circulation Fire Open Space Schools Sewer Collection System Water 55.63 square feet 29.67 square feet 16EDU 0.11 acres Basin D 160ADT Station No. 2 N/A ENSD E = 1. 747 JH=1.76/HS= 1.76 16EDU 3520 GPD Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes The proposed project is 6 units below the Growth Management dwelling unit allowance. V. ENVIRONMENTAL REVIEW The initial study (EIA-Part II) prepared in conjunction with this project determined that the project would not have a significant impact on the environment. The project falls within the scope of the City's MEIR for the City of Carlsbad General Plan Update (EIR 93-01) certified in September, 1994, in which a Statement of Overriding Considerations was adopted for cumulative impacts to air quality and traffic. An Average Daily Trip (ADT) of 160 would be generated by the proposed project. This ADT is consistent with the generation rate analyzed for the site in the MEIR. The project site has been disturbed by authorized grading and the surrounding properties are developed with residential land uses and all the support utilities and service infrastructure are been constructed. CT 99-07/CP 99-09/HDP^3-05 - LA COSTA FAIRWAY VILLAS**' August 4, 1999 Page 6 The City has received its annual Growth Management Traffic Monitoring Report. The Report has recorded an unanticipated intersection "level of service" (LOS) failure at Palomar Airport Road (PAR) and El Camino Real (ECR) during both the a.m. and p.m. peak hours. This potentially creates a changed circumstance negating reliance on previous environmental documentation. Pursuant to §15162 of the CEQA Guidelines a lead agency must prepare a "Subsequent" environmental documentation if substantial evidence (i.e., the recorded intersection failure) determines that a changed circumstance exists. However, case law has interpreted this section of the CEQA Guidelines to not require the preparation of a "Subsequent EIR" if mitigation measures are adopted which reduce the identified impacts to a level of insignificance. Please see the Environmental Assessment Form-Part II for a detailed description of the justification to recommend approval of the Mitigated Negative Declaration. In consideration of the foregoing, on June 9, 1999, the Planning Director issued a Mitigated Negative Declaration for the proposed project. The environmental document was noticed in the newspaper and no public comments were received during the 20 day public review and comment period. ATTACHMENTS: 1. Planning Commission Resolution No. 4595 (Mitigated Neg. Dec.) 2. Planning Commission Resolution No. 4596 (CT) 3. Planning Commission Resolution No. 4597 (CP) 4. Planning Commission Resolution No. 4598 (HDP) 5. Location Map 6. Background Data Sheet 7. Local Facilities Impact Assessment 8. Disclosure Statement 9. Reduced Exhibits 10. Full Size Exhibits "A" - "P" dated August 4, 1999 BK:eh:mh LA COSTA FAIRWAY VILLAS CT 99-07/CP 99-09/HDP 99-05 c oBACKGROUND DATA SHEET CASE NO: CT 99-07/CP 99-097 HDP 99-05 CASE NAME: La Costa Fairway Villas APPLICANT: Darling Pacific Builders REQUEST AND LOCATION: 16-unit airspace condominium on the south side of Gibraltar Street near the intersection of Jerez Court LEGAL DESCRIPTION: Lots 399. 400. and 401 of La Costa South Unit No. 5 APN: 216-300-04.-05. &-06 Acres: 1.18 acres Proposed No. of Lots/Units: 1 lot/ 16-units GENERAL PLAN AND ZONING Land Use Designation: RH - Residential High Density Allowed: 19 units per acre Density Proposed: 13.5 units per acre Existing Zone: RD-M Proposed Zone: N/A Surrounding Zoning and Land Use: (See attached for information on Carlsbad's Zoning Requirements) Zoning Land Use Site RD-M Vacant North RD-M Multi-family residential South RD-M Multi-family res./vacant East RD-M Multi-family residential West RD-M Multi-family residential PUBLIC FACILITIES School District: Encinitas/San Dieguito Water District: Carlsbad Sewer District: Leucadia Equivalent Dwelling Units (Sewer Capacity): 16EDU Public Facilities Fee Agreement, dated: September 14. 1998 ENVIRONMENTAL IMPACT ASSESSMENT Negative Declaration, issued June 9. 1999 Certified Environmental Impact Report, dated. Other, c oCITY OF CARLSBAD GROWTH MANAGEMENT PROGRAM LOCAL FACILITIES IMPACTS ASSESSMENT FORM (To be Submitted with Development Application) PROJECT IDENTITY AND IMPACT ASSESSMENT: FILE NAME AND NO: La Costa Fairway Villas - CT 99-07/CP 99-09/HDP 99-05 LOCAL FACILITY MANAGEMENT ZONE: 6 GENERAL PLAN: RH ZONING: RD-M DEVELOPER'S NAME: Darling Pacific Builders ADDRESS: 4195 E. Thousand Oaks Blvd.. Ste. 107. Westlake Village. CA 91362 PHONE NO.: (805)495-0215 ASSESSOR'S PARCEL NO.: 216-300-04. -05. & -06 QUANTITY OF LAND USE/DEVELOPMENT (AC., SQ. FT., DU): 1.18 acres. 16 units ESTIMATED COMPLETION DATE: A. B. C. D. E. F. G. H. I. J. City Administrative Facilities: Demand in Square Footage = 55.63 s.f. Library: Demand in Square Footage = 29.67 s.f. Wastewater Treatment Capacity (Calculate with J. Sewer) 16EDU Park: Demand in Acreage = 0.11 acres Drainage: Demand in CFS = N/A Identify Drainage Basin = Basin D (Identify master plan facilities on site plan) Circulation: Demand in ADT = 160 APT (Identify Trip Distribution on site plan) Fire: Served by Fire Station No. = Station # 2 Open Space: Acreage Provided = Schools: E=1.74,JH = 1.76,HS = 1.76 N/A ENSD Sewer:16EDU N/A K. L. Demands in EDU Identify Sub Basin = (Identify trunk line(s) impacted on site plan) Water: Demand in GPD = The project is 6 units below the Growth Management Dwelling unit allowance. 3.520 GPD City of Carlsbad tr W"vmCMMRMHMWBOTBmPlanning Department DISCLOSURE STATEMENT Applicant's statement or disclosure of csnain ownership interests on all applications which will require discretionary action on the part of the Chy Council or any appointed Board. Commission or Committee. The following information MUST be disclosed at the one of application sufarnittaJ. Your projecr cannot be reviewed until this information is completed. Please print Note: Person is defined as "Any individual, firm, Co-partnership, "joint venture, association, social club, fraternal organization, corporation, estate,. trust, receiver, syndicate, in this and any other county, city and county, city municipality, district or other political subdivision or any other group or combination acting as a unit" Agents may sign '^ provided below. document; however, the legal name and entity of the applicant and property owner must be 1 . APPLICANT (Not the applicant's agent) Provide the COMPLETE. LEGAL names and addresses of ALL persons having a financial interest in the application. If the applicant includes a corporation or partnership, include the names, title, addresses of all individuals owning more than 10% of the shares. IF NO INDIVIDUALS OWN MORE THAN 10% OF THE SHARES, PLEASE INDICATE NON- APPLICABLE (N/A) IN THE SPACE BELOW. If a publiclv-owned corporation, include the names, titles, and addresses of the corporate officers. (A separate page may be attached if necessary.) Parson N/A _ Com/Part ' Darling Pacific Builders Title N/A Title Developer Address N/A Address28720 Roadside Drive, Ste 274. Agoura Hills, CA 91376 OWNER (Not the owner's agent) Provide the COMPLETE, LEGAL names and addresses of ALL persons having any ownership interest in the property involved. Also, provide the nature of the legal ownership (i.e, partnership, tenants in common, non-profit, corporation, etc.). If the ownership includes a corporation or partnership, include the names, title, addresses of all individuals owning more than' 10% of the shares. IF NO INDIVIDUALS OWN MORE THAN 10% OF THE SHARES, PLEASE INDICATE NON-APPLICABLE (N/A) IN THE SPACE BELOW. If a publicrv- owned corporation, include the names, titles, and addresses of the corporate officers. (A separate page may be attached if necessary.) Person Stanley P. Mi 11 an Title Owner* Address 1069 Skyland Drive Zephyr Cove, NV 89448 Corp/Part N/A Title N/A Address N/A 2075 Las Palmas Dr. • Carlsbad. CA 92009-1576 • (T60) 438-1161 . PAV / J.NON-PROFIT ORvSK^nZATION OR TRUST If any person identified pursuant to ( I ) or (2) above is a nonprofit organization or urjsr. list the nam« and addresses of AiNY person serving as an officer or director of the non-profit organization or as trustee or beneficiary of the. Non Prof!OTrust__Ji/A _ Title N/A _ _ Non Profit/Trust Title _ N/A N/A Address H/A Address N/A 4. Have you had more than S250 worth of business transacted with any member of Ciry star:. Boards, Commissions, Committees and/or Council within the past rweive (12) months? [~J Yss [x~j No If yes, please indicate pe^on(s):_ NOTE: Attach additionai sheets if necsssary. 1 csrriiy that aJl the above information is true and correct to the best of my knowledge. Signature of owner/date V.Sicnaturs of applicant/date Stanley P. Mi 11 an Print or type name of owner Oar-ling Pacific Builders fArt Mora) Print or type name of applicant Signature of owner/applicant's agent if applicable/date Darling Pacific Builders (Art Mora) Print or type name of owner/applicant's agent H:AOMIN\COUNT5S\OISCLOSUfic STATHMENT 5/93 Pan- ? "' •> LA COSTA FAIRWAY VILLAS LEGAL DESCRIPTION UfJS 9ff. MO AM 481 Or U COSTAcar or cuaam, cottar or an MKO.Aecommc TO MAT raaaor MO. MOO.or SAH oaco cotamr. ASSESSOR'S PARCEL NUMBERS SUBDWIDERptanc CIVIL ENGINEER ZONING INFORMATION —«-- DISTRICTS AS SHOW* OH TH CT fl-i/Cni-3 (3/M/VO) z AU onAoma RU u ro orr x xu AUK? <w »•» aanr OK 45 ArritovsD rr sons snamm Arm EARTHWORK QUANTITIES HALE ENGINEERING LA COSTA FAIRWAY VILLAS CT 99-07 ffft < f M If TYPICAL PRIVATEDRIVEWAY SECTION MOT TO SCMT HALE ENGINEERING LA COSTA FAIRWAY VILLAS PROFILE/DETAIL SHEET LA SLOPE ANALYSIS COSTA FAIRWAY VILLAS o SLOPE ANALYSIS Color Dn D • Range Beg. OX 15% 25% 40% Range End 15% 25% 40% 100% Percent 56.4% 5.4% 2.3% 35.9% Area (Acres) 0.67 0.06 0.03 0.42 TOTAL ACRES: 1.18 Acres HALE ENGINEERING SURVEYMG UWO LA COSTA FAIRWAY VILLAS i LA COSTA FAIRWAY VILLAS CROSS SECTIONS LA COSTA FAIRWAY VILLAS O SECTION-A SECTION -B u SECTION-C SECTION-D HALE ENGINEERING u«o PLAMNWC LA COSTA FAIRWAY VILLAS CROSS SECTIONS LA COSTA FAIRWAY VILLAS LEGAL DESCRIPTION IOJS 399. 409 UOf 401 OF U COSTA SOVOf Vm HO. 9 . m IXenr OF OUUSUA comrrr or «jr HKO. frxn cr aummu. ASSESSOR'S PARCEL NUMBERS 3to-aoo-t.a urn t SUBDIVIDES OWNERSOUUIT F, muatP.O. aax iaie ~ — CIVIL ENGINEER *MO conor cotmrKUt PBGO, «l mill ZONING INFORMATION moroseo matt ton (no cnuoa HtOFOSED CWOKU HMt MH (Ma OUMf) sxtfims WE wwrr DISTRICTS SITE DATA: «. ronu. mnni w wna ~ it GENERAL NOTES i. TwoejuMrr mrwaajmf a /RDMVMKWWW nUBBBKL tf SNOW <W TV C7 VI-9/SFVJ-JA AU anuano rat u re orr LA COSTA FAIRWAY VILLAS ALTERNATE GRADING EXCLUSIVE WEAS TO K PWVAIELY WAWTMNED COMMON JREAS TO BE MAMTWNED BV MOMC OWED ASSOCIATION (HO.A.) /S^^HALE ENGINEERING OWL ENCMEEWtC SURVEYWC UWO PUWNWC 7840 coNvorcounr (sn) 715-1*20 SAN CNEGO. C* 12111 («l» 71S-14Z* FAN 20 0 20 40 «0 SCALE: T -30' LA COSTA FAIRTrAY VILLAS MAINTENANCE AREAS u coal fUlVlLW / 1 aut TUN rn.ONi lowi'n, uvti ruw TUNS LA coar* WIMIIW ITRU3 owmn. DAHINCrKiriC Di«6 . nattuDoiieti. »io7 o MM! TO* WllLDlNG floo^ 4 ^cof PUNS EXJIIDINC fl o fioot fuil i MDOF ruii. _[Atf . HOQKflAlJ flANS. u Ht.ua uooer>, metric 4IM I. TIOtdMO QUA 61. VI9TUII tlUiai,U.»9 o fmtwift 1 < CM>« 0WW KM IW.IIKJ* _flOOH < HOOf 'tXlLOUC Oil* 'C'• Mc&noncx* root run u.coaiA CxiUDill. /« L 'nouuD oue M. '> IOT o Glorgb Dunn & As*oci»tt»tma++*m*t*mfit *••* M*. CA m* R«vM«h ShMl Tltlh MAS.'f WEST 6UILDING. /IQO\ < AOOf bUILDIHC C 4 txHlOlilQ •fUll tunica MUST rioon. ruii. .. ~ BUHDIHG 'D' PIAH5 QMLIHC nciric CniDEUirta i. nouuooueu. <ioi' o .»»i*i 0un* 4 Aaacimt _£UIIPMC D IL£V*TIQH baiiONc • 'A' Li CO3TAyn.ua DAM.WG nciric tXJILDEHS i im i. nouuo oiieet.' 01' o ELEVATIONS exiiiDiiic» /no - MBM*» 4*0 MIM Cfco* •LJ.vLU'. *•.••» •• •. • •* Ton'."a an .a an "CD. Q "°°- D'HTE:; n4^rt*5~^ri 7mft**jrrt / f r,' r^jT'U.^JTi^. ^iA^ iuvATion - UST tUHtlOH ii£v<fio»- IAS; bUllDINC. 'K tHYAT.IO.ll • TMflU BUILDING 'C' EUVAJION IJl CO3U DAUWG fJCiriC O tr Oil* T'*fi HijBil!Miy KLJ-- ufL.v uv:;. fA.nniN& fun CP.O55 CfcQSS >-A OiUll. DAMINC rKiric jiu I. ncmauo coat*. > 01 o Ghrfif Dun* A JU*oci*t*t DCTAH5 SkMtfo PROPOSED PLANT PALETTE TREES- If BOXES MFQRMM. PtiM CLUSTER FLOWERING ACCENT SHRUBS-5 GAL aliiunu (Lily « m« Nle; n>Mf*> )BuM farm)Euiyop* MOtMfcj* Vino*' (Green Watad Busn Oasy) (JapaneM Hon«y«ucW« (Dwarf Roxamary) Petargonwn pMatum Saican Saw (Bakan Ivy Gat*»jmj NUHTAIN BtCH 20HB I 532 UNITS FBI TEA* ZONE II 20 WITS PEE TCU I n mns p« TEAS AintMTIC COmOlLBI AS PEJ CTTTUIH S8DT OFT DCTICETC SPRIMOEB HEADS SRINIUE HEUS WTO CHBCX VALVB . UCM A Soutu uuti to a HO. 2M.-iOo-(M,oS d OA TOM. a 51.1SS Bf, I.IT&MU69 .ZONE RDM is-rt iwna rnoroseo Bo. or UHDOCAPE 5 fir E<4% or u ALLOWAKlLt tOl COVER.AOE . Si.TOO W[4«»0f OF DcvfidPMU TEH n>i|j orti JfACE AC1IVI OftU SfACt .OrtK ArMX 5272 tf HIIVATE bMXYMO CFDt 2ACC 4700 S NOTES: I. Ml.STO£ETTA&SSH«U.eElOOkTEIIAMWMJM74raUTSD£O e Arehifccture 830 S. QMnttato Annue QlandllA. Ca. 91205 VIUA5 wane &UILDERS !87»0 R»OS{OE DUVt, » I Cnngio Dazan & Associates SkMtTWti LANDSCAPE PLAN /I5U07TD SkMtNo. I I