HomeMy WebLinkAbout1977-01-26; Planning Commission; ; CUP 131 - ENCINA JOINT WATER POLLUTION CONTROLf
STAFF REPORT
January 26, 1977
TO:
FROM:
PLANNING COMMISSION
PLANNING DEPARTMENT
CUP 131 CASE NO:
APPLICANT:
REQUEST:
CITY OF CARLSBAD
Conditional Use Permit to allow a 12 X 42-Foot
modular temporary office at the Encina Joint
Water Pollution Control Facility.
Section I: Recommendation:
Staff recommends that CUP 131 be APPROVED based on the following find-
ings and subject to the following conditions:
1) The requested use is necessary or desirable for the development
of the community and is essentially in harmony with the various
elements and objectives of the General Plan, and is not detri-
mental to existing uses or to uses specifically permitted in the
zone in which the proposed use is to be located because:
a) The requested structure will be located within boundaries
of an existing facility.
b) The existing facility site is designated by the General
Plan for public utility uses.
c) The requested structure will provide necessary office space
for administration (permanent plant manager).
2) The site for the intended use is adequate in size and shape to
accommodate the use because:
a) The subject site consists of approximately 25 acres and is
fenced and screened from surrounding development.
3) All yards, setbacks, walls, fences, landscaping and other features
necessary to adjust the requested use to existing or permitted
future uses in the neighborhood will be provided and maintained
because:
a) The requested structure will be located inside the existing
facility site and will not be readily visible from surrounding
properties.
b) The location of the subject structure will be at least 65 1
from the nearest property line and at least 90 1 from the
nearest existing structure.
-1-
4) The street system serving the proposed use is adequate to
properly handle all traffic generated by the proposed use
because:
a) An existing 14 1 paved roadway is existing on site. The
proposed structure is to be located adjacent to the existing
roadway.
b) A maximum of 2 additional employees will result from the
proposed structure.
CONDITIONS:
1) The approval is granted for the land described in the application
and attachments thereto, as shown on the plot plan submitted
labeled Exhibit 11 A11 , dated December 16, 1976. The structure shall
be in substantial conformance to the design shown in the architec-
tural elevations, Exhibit 11 B11 , dated January 18, 1977.
Section II. Background
Location and Description of Property
The site is approximately 25 acres and contains the existing Encina
Water Pollution Control Facility. The area has been previously
developed and primary wastewater treatment facilities, including sed-
imentation tanks, digesters and a 3000 sq.ft., operations building,
are the major existing structures on site. The entire developed
area has been extensively landscaped and fenced.
The specific location of the proposed structure is adjacent to the
main entrance road to the operations building. The site is approx-
imately 65 feet from the fenced and landscaped northern property line.
The adjacent northern property is approximately 10-15 1 higher in
elevation than the subject site. The temporary structure is proposed
to be located approximately 100 1 from existing parking facilities,
(9 stalls).
Existing Zoning:
Subject Parcel:
North:
South:
East:
West:
Surrounding Land Use:
Subject Parcel:
North:
South:
East:
West:
P-U
M
R-1-10,000
M/P-C
R-1-10,000
Encinia Water Pollution Control
Facility.
Vacant
Vacant
I-5
Railroad R.O.W
-2-
Environmental Impact Information:
An Environmental Impact Assessment Form has been submitted for the
project. A Negative Declaration has been issued for the project
based on the following findings:
1) The project will require no grading.
2) The site has already been developed with water treatment facilities;
therefore destruction to the natural environmental will be minimal.
3} The buildings will be screened from view from I-5.
4) The project will not generate significant amounts of traffic.
General Plan Information:
The Land Use Plan Map designates the subject site for Public Utilities,
(U) uses.
Public Facilities:
Public Facilities will be available concurrent with need for the
subject project.
DISCUSSION:
Title 21 states that a Conditional Use Permit is necessary for public
buildings. The structure will be of the type that is designated by
the Uniform Building Code as 11 movable 11 but not a mobile home. The
structure willbe similar to those used by public schools for temporary
classrooms. The requested building will be designed to be architect-
urally pleasing.
The structure must be designed to be movable because it is anticipated
that during plant expansion (Federally mandated secondary treatment,
deadline July 1977) construction may take place on or near the presently
planned site. In addition, a new permanent office structure will be
constructed as a part of the expansion process. At such time a new
office is usable, the subject structure will be totally removed.
At the present time, there is no available office space for a full-
time General Manager for the plant. Because of the secondary treatment
expansion and subsequent plant activities, a permanent plant manager
will be on site full-time.
A total of 12 employees now work at the facility, nine parking spaces
now exist on the site.
Title 21, Section 21.44.130 (18) states the following:
USE-OFFICES, not providing customer service on the
premises.
PARKING SPACES REQUIRED:
or for each eight-hundred
whichever is the greater.
building is 3000 Sq.Ft.
-3-
one for each four employees
Sq. Ft., of gross floor area,
The existing operations
The maximum number of employees to be added with the requested structure
will be two. The requested structure will be 500 Sq.Ft. The maximum
required parking for the entire plant including the proposed structure
is 4 spaces. Nine spaces are provided.
TH:ar
1/13/77
-4-
TABULATION OF BIDS
Vendor
Mobile-Facilities, Inc.
13926 Carmenita Road
Santa Fe Springs, Ca. 90670
Bert•s Mobile Home Sales
1111 E. Main Street
El Cajon, Ca. 92021 ...
Aquarious Structures
1364 Pioneer Way •
El Cajon, Ca. 92020
14odular Leasing
17232 E. Railroad
Industry, Ca ..
Designed Facilities
3240 N .. Durfee Avenue
El Monte, Ca.
Mobilease Corp.
3031 La Jolla
Anaheim, Ca.
Modular Facilities
P.O. Box ·:5723
Fullerton, Ca.
Space Rentals
3441 Main Street
Chula Vista, Ca.
Caleasco Inc.
121 N. Harbor Blvd.
• Santa Ana, Ca. 92703
Cost .
$28,299.00
Late Bid
late Bid
No Response
No Resp1Jnse
No Response
No Response
No Response
No Response
~xhibit A
City or' Carlsbad
1200 Elm Avenue
Carlsbad, Ca. 92008
SPECIFICATIONS: Modular Office Unit
General Specifications:
1. One modular office unit with fully insulated double wall
construction with interior partitions as shown on drawing
(Exhibit "A"). Total width of unit shall be approximately
12' wide and 42' in length excluding landings.
2. Exterior walls shall be 2X4 studs 16" O.C. with R-11 insulation.
Exterior sheathing shall be 7/16~ Forrest Fiber .
._.;3. Exterior doers to be located as shown on drawing (Exhibit "A'').
Entry wi·ll be a single door, rather than double as shown on
~xhibit "A". Doors will open outward and each door will h~ve
locking capabilities as an integral part of the door latch with
outside entry by key (all doors to be keyed alike with 2 keys per
door). Entry·door to be tempered glass with aluminum frame. Rear
door to be 1 3/8" solid core wood (paint grade).
4. Exterior trim shall include a mansard roof frame for front and
sides.of unit, window trim, corner trim, horizontal wood bottom
and shingle siding on front of uriit~ Skirting with vents will
be provided. Colors to be consistent with.materials used.
5. Aluminum sliding windows shall be provided in .sizes and locations·
as shown on drawing (Exhibit "A"). Glass shall be standard
strengt~ and aluminum screens will be included.
6. Floor shall consist of steel hoists 24" O.C. with 3.4" plywood
{CDX) subfloor and 3-811 particle board underlayment.
7. Roof shall consist of 2x6·rafters, 24" O.C. with 3/8" plywood
(CDX) sheathing with clips. Roof finish shall be gravel and
insulation shall be R-11.
8. Interior f•inish to have vinyl asbestos til·e on the floors, •
an acoustical ceiling with a washable surface and prefinished
wood paneling on the walls. Interior walls shall be trimmed
with base and corner moulding.
9. Interior partitions shall be 2X4 studs 16" O.C. Interior doors
shail be 1 3/8" hollow core wood (paint grade).
10. Bathroom walls shall be ½11 drywall, taped an~ painted with
wainscotting.· -.
11. Plumbing shall consist of l UR or equal-water closet and one wall
hung lavatory. Water and sewer cqnnections shall be stubbed 9ut
2' ·outside unit.
12.
13.
One (1) Bard, or.equal, retrigerated air conditioning, v~nti-
lating and heat unit (minimum 2 ton capacity) shall be installed
as shown on drawing (Exhibit "A"}. The unit shall be controlled
with a thermostat. Air -shall be ducted through an overhead
system designed so as to provide 4 diffusers and 2 air returns
to provide a uniform flow of heat and ·cool to the entire unit.
Six 2-tube rapid start 4' flourescent light fixtures with wrap-
around diffusers shall be ins~alled as shown on drawing (Exhibit
"A"). One incandescent light fixture shall be installed in the
bathroom as shown on drawing (Exhibit "A").
14. 110 volt, 70 amp electrical wiring with 12 gauge wiring to the
15. ~-
16.
17.
~ duplexes of ten electric outlets with a 20 amp duplex in each
one (ground plug type) with an adequate breaker assembly to protect
the.unit. ~pacing of duplexes and switches shall be as shown on
the drawing (Exhibit "A").
Unit must meet Federal, State, City of Carlsbad and all ·other
applicable codes and safety standards.
Floor plan showing sizes, locations, and types of doors, lights,
windows, electric outlets, breaker assembly and air ducting unit(s}
to be submitted with bid. Elevation view showing exterior features
and trim.shall also be submitted with bid.
Bid price to includ~ all related costs involved in the delivery,
set up and taxes on a "ready for occupancy" status at the Encina
Water Pollution Control Facility ·located at 6200 Avenida Encinas,
Carlsbad, California. ·A City of Carlsbad business license is •
required as well as building permit. Set tip shall include cornplet~
assembly, leveling, installation of piers and P?ds at a location at
6200 Avenida Encinas as specified at time of delivery ..
-• 18. Attached is a drawing marked Exhibit "A" and~ is herewith incorporated
19.
• 20.
as part of these ~pecifications.
Carlsbad zoning requirement prohibit office trailers and therefore
bids on trailers will not be accepted. The desired structure should
be a UBC Modular Type V non~rated building.
Access will be by handicap ramp with handrails, as specified by the •
UBC, for the front entry . .Side door will be provided with steps· and
handrails to UBC Code.·
EXHIBIT B
• . I
,.