HomeMy WebLinkAboutCUP 91-03C; BP/ARCO FACILITY 5792; STRUCTURAL CALCULATIONS FOR PALOMAR AIRPORT CAR WASH; 2023-07-11 STRUCTURAL CALCULATIONS FOR
PALOMAR AIRPORT CAR WASH (PACW)
7/11/2023
BASIN RETAINING WALL RESUBMITTAL
1
1
NAJARS
ENGINEERING
Cantilevered Retaining Wall
LIC# : KW-06018251, Build:20.22.7.25 JG (c) ENERCALC INC 1983-2022
DESCRIPTION:Basin Cantilevered Wall
Project File: PACW Retaining Walls.ec6
Project Title:Engineer:Project ID:Project Descr:
Code References
Calculations per IBC 2012 1807.3, CBC 2013, ASCE 7-10
5.50
0.50
0.00
36.00
1,500.0
45.0
0.0 350.0
Criteria Soil Data
Retained Height =ft
Wall height above soil =ft Active Heel Pressure =psf/ftSlope Behind Wall
Height of Soil over Toe in
Water height over heel =ft
=
=
110.00=pcf
=
Soil Density, Heel
=Passive Pressure =psf/ft
Allow Soil Bearing =psf
Soil Density, Toe 110.00 pcf
Footing||Soil Friction =0.400
Soil height to ignorefor passive pressure =12.00 in
Equivalent Fluid Pressure Method
Surcharge Loads Adjacent Footing Load
Load Type
0.0 Lateral Load =562.0 #/ft
0.0
0.0
0.00.0
Axial Load Applied to Stem
Wall to Ftg CL Dist =0.00 ft
Wind on Exposed Stem psf0.0=
Lateral Load Applied to Stem
Surcharge Over Heel =psf Adjacent Footing Load =0.0 lbs
Axial Dead Load
(Service Level)
=lbs
Footing Type Spread Footing
Surcharge Over Toe Footing Width =0.00 ft...Height to Top =2.33 ft Eccentricity =0.00 in...Height to Bottom =1.33 ft
Used To Resist Sliding & Overturning
Used for Sliding & Overturning
==0.0 ft
Axial Live Load =
Base Above/Below Soil
lbs
=
Axial Load Eccentricity ==Poisson's Ratio 0.300
at Back of Wall
in (Strength Level)
Earth (H)=
2
2
D
Cantilevered Retaining Wall
LIC# : KW-06018251, Build:20.22.7.25 JG (c) ENERCALC INC 1983-2022
DESCRIPTION:Basin Cantilevered Wall
Project File: PACW Retaining Walls.ec6
Project Title:Engineer:Project ID:Project Descr:
Design Summary
Wall Stability RatiosOverturning =2.16
Global Stability =24.21
OK
Sliding =2.82 OK
Total Bearing Load =3,293 lbs...resultant ecc.=13.73 in
Eccentricity outside middle thirdSoil Pressure @ Toe =1,402 psf OK
Soil Pressure @ Heel =0 psf OK
Allowable =1,500 psfSoil Pressure Less Than Allowable
ACI Factored @ Toe =1,963 psf
ACI Factored @ Heel =0 psf
Footing Shear @ Toe =4.7 psi OK
Footing Shear @ Heel =0.0 psi OK
Allowable =75.0 psi
Sliding Calcs
Lateral Sliding Force =1,664.5 lbs
less 100% Passive Force
less 100% Friction Force
Added Force Req'd
....for 1.5 Stability =
0.0=
1,317.2
3,368.8
==
0.0
-
lbs
lbs
lbs OK
lbs OK
-
Masonry Block Type =
Stem Construction Bottom
Ratio > 1.0
Shear.....Actual
Design Height Above Ftg =0.00ft
Wall Material Above "Ht"=Masonry
Thickness =8.00
Rebar Size =#5
Rebar Spacing =16.00
Rebar Placed at =EdgeDesign Data
fb/FB + fa/Fa =1.255
Total Force @ Section
=1,242.6lbs
Moment....Actual
=2,276.3ft-#
Moment.....Allowable =1,812.8
=13.6psi
Shear.....Allowable =45.2psi
Wall Weight =84.0psf
Rebar Depth 'd'=5.25in
Masonry Data
f'm =1,500psiFs=psi 20,000Solid Grouting =Yes
Modular Ratio 'n'=21.48
Equiv. Solid Thick.=7.63in
Concrete Dataf'c =psi
Fy =
Masonry Design Method ASD=
Load Factors
Building Code
Dead Load 1.200
Live Load 1.600
Earth, H 1.600
Wind, W 1.600
Seismic, E 1.000 psi
Service Level
=lbsStrength Level
Service Level
Strength Level =ft-#
Service Level
Strength Level =psi
Design Method =ASD SD SD
Vertical component of active lateral soil pressure IS
NOT considered in the calculation of soil bearing
Anet (Masonry)=91.50in2
3
3
Cantilevered Retaining Wall
LIC# : KW-06018251, Build:20.22.7.25 JG (c) ENERCALC INC 1983-2022
DESCRIPTION:Basin Cantilevered Wall
Project File: PACW Retaining Walls.ec6
Project Title:Engineer:Project ID:Project Descr:
4.75
0.67
18.00
Footing Torsion, Tu =
=
ft-lbs0.00
Min. As %
Footing Allow. Torsion, phi Tu
0.0018
=ft-lbs
Footing Data
If torsion exceeds allowable, provide
f'c
0.00
=2,500psi
Toe Width =ft
Heel Width =
Key Distance from Toe
Key Depth
Key Width =in
=in
=
0.00
0.00
0.00 ft
Footing Thickness =in
5.42=
Cover @ Top =2.00 in@ Btm.=3.00 in
Total Footing Width
=150.00 pcfFooting Concrete DensityFy =60,000 psi
Footing Design Results
Key:
=
No key defined
Factored Pressure
Mu' : Upward
Mu' : Downward
Mu: Design
Actual 1-Way Shear
Allow 1-Way Shear
Toe:#4@ 6.17 in, #5@ 9.56 in, #6@ 13.58 in, #7@ 18.51 in, #8@ 24.38 in, #9@
30.86 in, #10@ 39.19 in
Flush heel condition. No reinforcing required.
=None Spec'd
=
=
=
=
=
1,963
14,679
8,041
6,639
4.71
75.00
Heel:
0
0
1
1
0.02
75.00
HeelToe
psf
ft-#
ft-#
ft-#
psi
psi
Heel Reinforcing =
Other Acceptable Sizes & Spacings
Key Reinforcing
Toe Reinforcing =# 6 @ 13.58 in
Min footing T&S reinf Area
Min footing T&S reinf Area per foot
If one layer of horizontal bars:
2.11
0.39
#4@ 6.17 in
#5@ 9.57 in
#6@ 13.58 in
in2
in2 /ft
If two layers of horizontal bars:
#4@ 12.35 in
#5@ 19.14 in
#6@ 27.16 in
supplemental design for footing torsion.
phiMn 24,788=
OKOK
Flush heel condition. No reinforcing required.
OK - Flush
4
4
Cantilevered Retaining Wall
LIC# : KW-06018251, Build:20.22.7.25 JG (c) ENERCALC INC 1983-2022
DESCRIPTION:Basin Cantilevered Wall
Project File: PACW Retaining Walls.ec6
Project Title:Engineer:Project ID:Project Descr:
Summary of Overturning & Resisting Forces & Moments
.....RESISTING..........OVERTURNING.....Force Distance Moment Distance Moment
Item
Force
ft-#lbs ftft ft-#lbs
Sloped Soil Over Heel
=Surcharge over Heel
=
Surcharge Over Heel
=
=
Adjacent Footing Load
=Adjacent Footing Load
Axial Dead Load on Stem =
=* Axial Live Load on Stem
Soil Over Toe
Surcharge Over Toe
Surcharge Over Toe
Load @ Stem Above Soil
=
=
=
1,567.5 2.38 3,722.8=
=
=
Stem Weight(s)
=
504.0 5.08 2,562.0
Earth @ Stem Transitions
=Footing Weight
=
1,219.5 2.71 3,304.8
Key Weight
=
Added Lateral Load
lbs
=4,444.0
Vert. Component
Total
=
3,293.0
562.0 3.33 1,871.5
9,600.6
* Axial live load NOT included in total displayed, or used for overturningresistance, but is included for soil pressure calculation.
Total =R.M.
=1,664.5 O.T.M.
=
Resisting/Overturning Ratio =2.16
Vertical Loads used for Soil Pressure =3,293.0 lbs
Vertical component of active lateral soil pressure IS NOT considered in
the calculation of Sliding Resistance.
Vertical component of active lateral soil pressure IS NOT considered in
the calculation of Overturning Resistance.
Soil Over HL (ab. water tbl)
Soil Over HL (bel. water tbl)
2.0 5.42
5.42
10.9
10.9
Watre Table
Buoyant Force =
HL Act Pres (ab water tbl)
HL Act Pres (be water tbl)
1,102.5 2.33 2,572.5
Hydrostatic Force
Tilt
Horizontal Deflection at Top of Wall due to settlement of soil
(Deflection due to wall bending not considered)
Soil Spring Reaction Modulus 250.0 pci
Horizontal Defl @ Top of Wall (approximate only)0.043 in
The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe,
because the wall would then tend to rotate into the retained soil.
5
5
Cantilevered Retaining Wall
LIC# : KW-06018251, Build:20.22.7.25 JG (c) ENERCALC INC 1983-2022
DESCRIPTION:Basin Cantilevered Wall
Project File: PACW Retaining Walls.ec6
Project Title:Engineer:Project ID:Project Descr:
Rebar Lap & Embedment Lengths Information
Stem Design Segment: Bottom
Stem Design Height: 0.00 ft above top of footing
Calculated Rebar Stress, fs = 25113.14 psi
Lap Splice length for #5 bar specified in this stem design segment =47.09 in
Development length for #5 bar specified in this stem design segment =47.09 in
Hooked embedment length into footing for #5 bar specified in this stem design segment =7.00 in
As Provided =0.2325 in2/ft
As Required =0.2944 in2/ft
6
6
Cantilevered Retaining Wall
LIC# : KW-06018251, Build:20.22.7.25 JG (c) ENERCALC INC 1983-2022
DESCRIPTION:Basin Cantilevered Wall
Project File: PACW Retaining Walls.ec6
Project Title:Engineer:Project ID:Project Descr:
7
7
3'-0"
8" w/ #5@ 16"
Solid Grout
4'-9"
5'-5" .;
1' 6
8"
:-
Cle r Cov~--02-625"
5'-6"
3"
Cantilevered Retaining Wall
LIC# : KW-06018251, Build:20.22.7.25 JG (c) ENERCALC INC 1983-2022
DESCRIPTION:Basin Cantilevered Wall
Project File: PACW Retaining Walls.ec6
Project Title:Engineer:Project ID:Project Descr:
8
8
562.00psf
(Service-Level
Pp= 3368.75#
4'-8"
1665#
■ Lateral earth pressure due to the soil BELOW water table