HomeMy WebLinkAbout2864 WHIPTAIL LOOP; 107; FPC2018-0023; PermitPERMIT REPORT Fire Permit Print Date: 02/29/2024 Job Address: 2864 WHIPTAIL LOOP, # 107, CARLSBAD, CA Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2091201000 Track#: Valuation: $65,625.61 Lot#: Occupancy Group: Project#: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check#: Plan Check#: Project Title: Description: ELEVATE SHELL TO WAREHOUSE -SPRINKLER Tl 7-100 (18 HEADS) Applicant: EPIC FIRE PROTECTION INC ADAM BOISVERT 765 TURTLE POINT WAY SAN MARCOS, CA 92069-8126 (760) 310-6122 FEE FIRE NFPA 13 or 13R System 7 -100 heads Total Fees: $536.00 Total Payments To Date: $536.00 Ccityof Carlsbad Permit No: FPC2018-0023 Status: Closed -Finaled Applied: 01/18/2018 Issued: 02/01/2018 Finaled Close Out: 04/16/2021 Final Inspection: INSPECTOR: Fieri, Dominic FPContractor: EPIC FIRE PROTECTION INC 765 TURTLE POINT WAY SAN MARCOS, CA 92069-8126 (760) 310-6122 Balance Due: AMOUNT $536.00 $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 442-339-2665 I Inspections: 442-339-2660 I www.carlsbadca.gov MATERIAL DATA SUBMITTAL ELEVATE Tl SUITE 107 BUILDING B RE.CEIVED JAN 1 8 2018 CAl{L~bAIJ FIRE DEPARTME T EPIC FIRE PROTECTION, INC. 765 TURTLE POINT 'NAY SAN MARCOS, CA 92069 (760)310-6122 FPv<(760)798-0556 G: FIRE SPRINKLER CORPORATION QUICK RESPONSE AUTOMATIC SPRINKLERS GL SERIES UPRIGHT• PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) DESCRIPTION AND OPERATION The Globe Quick Response Gl Series Sprinklers are a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element This provides sprinkler operation approximately six times faster than ordinary sprinklers. While the Quick Response Sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard spray sprinklers are specified when allowed by the applicable standards. It offers the additional feature of greatly increased safety to life and is available in various styles, orifices, temperature ratings and finishes to meet many varying design requirements. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction. The heart of Globe's Gl Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern depending upon the deflector style used. TECHNICAL DATA • See reverse side for Approvals and Specifications. • Temperature Ratings -135°F (57°C), 155°F (6B'C), 175"F (79"C), 200°F (93°C), 286°F (141'C) •Water Working Pressure Rating -175 psi (12 Bars) • Factory tested hydrostatically to 500 psi (34 Bars) • Maximum low temperature glass bulb rating is ~7°F (-55°C) • Frame -bronze • Deflector -brass • Screw -brass • lodgement Wire -stainless steel • • Bulb seat -copper • Spring -nickel alloy • Seal -teflon • Bulb -glass with alcohol based solution, 3mm size QUICK RESPONSE UPRIGHT CONVENTIONAL QUICK RESPONSE PENDENT VERTICAL SIDEWALL 18DIQ QUICK RESPONSE HORIZONTAL LPC/CE SIDEWALL HORIZONTAL SIDEWALL •SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING CLASSIFICATION ORDINARY INTERMEDIATE HIGH 40TT AIRPARK DRIVE, STANDISH.MICHIGAN 48658 JULY 2012 A-"2/J BULB COLOR ORANGE/RED YELLOW/GREEN BLUE N.F.PA MAXIMUM CBUNG TEMPERATURE ~ • FAX989-846-9231 BULLETIN GL5615, REV. #9 Q UICK R ESPONSE AUTOMATIC SPRINKLERS GL SERIES UPRIGHT. PENDENT• VERTICAL SIDEWALL HORIZONTAL SIDEWALL • CONVENTIONAL (OLD STYLE) SPECIFICATIONS NOMINAL .. K" FACTOR THREAD SIZE LENOTH1 FINISHES 2.8 (39 metric) 42 (59 metric) 5.6 (BO metric) 7.8 (111 metric) 8.1 (116 metric) METRICCONVERSK>NSAAEAPPROXIIMTE. 'HORIZONTAL SIOEWAU.. IS 2 at1rr. 1 FlNtSHE.S AVAIi.ABLE ON SPECW. ORDER. 112" NPT 1/2" NPT 112" NPT 112" NPT 3/4" NPT 2 1/4" (5.7cm) 2 1/4" (5.7cm) Factory Brol"'CZE Ct-tome 2 1/4" (5. 7cm) 2 1/4" (5.7cm) 'Nhlte Polyester ~ 2 7/16" (6.2cm) Black Polyester 2.J 1 AVAi.ABLE AS cUtJ.a UGTED CORROSN)N RE&&STANT WHEN 6PECIFEO ON ORDER. APPROVALS STYLE SOI K """""' 135"F 156'F 11S'F l!lO"F ,..., dAJa FM lPC CE NVC•D08 MOOEl FAClOR src lll'C 7!rC 93'C Hl"C IEA101.Q2-E Gl2S15 2.8 "' X X X X X X ---X Gl.<215 ,.2 "' X X X X X X ---X '-"RIGHT Gl.51115 5.6 1.1.aH X X X X X X X X X X Glans 1.tf 1.1.aH X X X X X X ---X GlB118 &1 1.1.aH X X X X X X X X X X Gl2B01 2.8 "' X X X X X X ---X ~~ u "' X X X X X X ---X PEIClENTC ' s., LHIOH X X X X X X X X X X ~ 1.tf 1.1.aH X X X X X X X --X GlB106 &1 1.1.aH X X X X X X X X X X VER11CAL = 5.6 "' X X X X X X X --- SIJEWAl.l.1 Gl.8133 &1 "' X X X X X X ---- Gl282S§ 2., "' X X X X X X ---X l«lRJZDHTAI. Gl.422ll§ ◄.2 "' X X X X X X ---X SllEWAU. GI.S82S§ 5.8 LHIOH X X X X X X X --X Gl.56V' 5.6 1.1.aH X X X X X --X X -GLB127§ &1 UilOH X X X X X X ----CONIIENTDIW. GISI>◄ 5.8 1.1.aH X X X X X --X X -!OlllS1Yt.E) Gl.81'5 &1 UilOH X X X X X --X X - 1SPRlNJCLERS S"""'1.1. BE l.MTEDAS PER TltE REQUIREMENTS OF NFPA13AND NlY OTHER RELATED 00CUIENTS. §HORlZONTAL. SIDEWAU c!Jl..u. LISTED FOR DEFLECTOR .... TO ,r BELOYV THE CEA.ING. FM APPROVED .. TO~ BELOW THE CEIUNQ. •INSTALL IN ACCORMNCE TO 8SS308 AHO ANY OTHER RELATED DOCUMENTS. 'PENDENT VERTICAL 6/0EWALL etJt.u. LISTED FOR '1 MIN. SPACl«J. 11JPRIGHT VERTlCAL SIOEWAU. dJluli LISTED FOR 8' t-lH. SPACING. OH: ORDINARY HAZARD Ut UGHT HAZARD ~,r NPT ORDERING INFORMATION SPECIFY • Quantity • Model Number • style • Orifice • Thread Sizes • Temperature • Finishes desired • Quantity -Wrenches -P/N 325390 (1/21; PIN 312366 (LO.) GL.BE GLOBE-PRODUCT WARRANTY ~obe agrees to repair or replace any of its ovm manufactured products found to be defective in material or 'MH'kmanship for a period of one year from date of shipment For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). 4DTT AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 FAX 989-846-9231 • Ol"W'\ "'JAO ,.,..,.,0 ·--..................... ........... ,,~~--.cum flll[ SPRIIIICllR tuRJIOUTION JUNE2012 PRINTED U.S.A BULLETIN GL5615, REV. #9 Page 1 of6 'JIKINCG® TECHNICAL DATA ESFR PENDENT SPRINKLER VKSOO (K14.0) Th• Viking Corporation, 210 N lndustrlal Part( Drlve, Hastings Ml 49058 Tatephona: 269-945-9501 Technical S.rvlcu: an-3114-5464 Fax: 269-818-1680 Email: techavcs@viklngcorp.com Visit the Viking -bait• for the lateot adltlon of lhl• technical data_, www.vlklnggrouplnc.com 1. DESCRIPTION Viking Early Suppression Fast Response (ESFR) Pendent Sprinkler VK500 is a fast response tu-element type sprinkler designed for 8Miy fino suppression. With a 14.0 (202 metric•) nominal K-l'actor and special defleciar, this sprinkle< produces larve, hlg~ntum water droplets In a hemispheric pattam below Iha deflector. This pennils penetration of the fire plume and direct wetting of Iha burning fuel S<lface while cooling Iha atmosphere aafy In Iha development of a high-challenge rn. V1king VK500 ESFR Pendent Sprtnklen, may be used In the protection of ordinary types of storage. However, !hay are prtmalily Intended to protect Iha follow4ng types of stor- age, which tend to produce severe-challenge fires: palletized and solid pile storage and single, double, multiple raw, and po,table open rack storage (no open-top containers or solid shelves). Viking ESFR Pendent VK500 Sprinklers provide protection of most common storage materials, including: -Encapsulated or unencapsu!ated aass I, II, 111, and IV commodities•. --Cartoned and uncartoned unexpanded plastics". --Cartoned and uncartoned expanded plastics•. • Refer the Approval Charts and Design Cntena on pegea ~ for cUL.us Li111ng and FM Approval requirements that must be foMowed. In addition, soma storage 11m1ngementa of rolled paper, aerosols, and rubber tires may be prdec1ed by Viking ESFR Pendent Sprinkler VKSOO. 2. LISTINGS AND APPROVALS •®• cULuo U.ted: Category VNWH ~ FM Approved: Claso 2008 NYC Approvad: MEA89-92-€, Volume 18 ~ VdS Approved: Cartiflcate G4010001 ( E CE Certified: Standard CUAP11.03/03, EC<:ertlficato of conformity 1725-CPO-HOOOS, ETA-10/0306 @ CCCF Approved: Approved by the China Certification Center for Are Products (CCCF) The 10284 and 11350, VK500, ESFR Pendent Sprinkler Assembly oonforms to Iha provision of CUAP11.03/03 standard. CUAP11.03/03 approvals are provided by: FM Approvals Ltd. 1 Windsor Olals Windsor, Berkshire, UK SL4 1 RS Approval Certificate No. issued December 20. 2010. NOTE: other International approval certlflcatas are available upon n,quest Refer Approval Chart 1 and Design Criteria on page 3 for cULua Listing requirements that must be followed, and refec to Approval Chart 2 and Design Criteria on page 4 for FM Approval requirements that must be followed. 3. TECHNICAL DATA Speclflcallona: AvaRable since 2000. Minimum Operating Preoaure: Refer to NFPA 13 or FM Global Loss Prevention Data ShMts. Maximum Working PrMSUre: 175 psi (12 bar). Factory tested hydrostallcally to 500 psi (34.5 bar). Thread size: 314" (20 rrvn) NPT Nominal K-Factor: 14.0 U.S. (202 metric .. ) "Molric:K.fact>,,,_,_llhown ilwhonpn11...-ola.-.ndr1bor. wt,en_,.11-.redlnkl'o. <lvldelhe rne<rlcK--llhownby 10.0. Overall Length: 2-7/8" (73 mm) Defleciar Diameter. 1-314" (44.5 mm) Material Standardo: Frame Casting: &ass UNS-C84400 Deflector Phosphor Bronze UNS-C51000 Form No. F _060198 17.02.02 Rev 17.1 Replaces Form No. F _060198 Rev 16.1 (Added CCCF approved sprinkler.) Page 2 of6 'JIKINCG® TECHNICAL DATA ESFR PENDENT SPRINKLER VKSOO (K14.0) The Viking Corporation, 210 N lndustrlal Parti Drive, Haatlnas Ml 49058 T•laphone: 269~5-9501 Technical Sarvlcas: an-3114-5464 Fax: 269-818-1680 Email: techsvco@vlklngcorp.com Visit the Viking webelte for the latest adltlon or this technleal data page: www.vlklnggrouplnc.com Seel for Sprinkler 11350: Slalnless Steel UNS-S31603 Seal and Insert Assembly for Sprtnkler 10284: Copper UNS.C11000 and Stainless Steel UNS-530400 BellevlUe Spring Sealing Assembly: Nid<el Alloy, coated on both aides with PTFE Tape Compreaslon Screw: Stainless Steel UNS-S31603 Trigger and Support: Stainless Steel UNS-S31600 Fusible ElernentAsoembly: Beryllium Nickel, coated wl1h black acrylk: paint. Ejector Spring (Sprinkler Base Part No. 11350 only): 17-7 Stainless Steel Ordering Information: (Also refer to the current Viking price llsl) Order ESFR Pendent Sprinkler VK500 by first adding Iha appropriate suffix for Iha sprinkler finish and then Iha appropriale suffix for the temperature rating to Iha sprtnkler base part number. Finlall Suffix: Brass s A Temperotunl Suffix: 165 •F (74 "C) = C, 205 •F (96 'C) = E For example, sprinkler 10284 with a Brass flnlsh and a 165 'F (74 "C) temperature raUng s Part No. 10284AC. Available Flnlohn And Tempenrtun, Ratlnga: Refer to Table 1. Accaoories: (Also refer to Iha Viking webolle.) Sprinkler Wrencheo: A. Part No. 13635W/B (double-<!flded wrench • Use Side A. Side B Is for use with K25.2 ESFR Pendant Sprlnkl..-VK510) Available since 2006. B. Part No. 10285W/8 (no longer available) Sprlnklor Cabinet: Twelve-head capacity: Part No. 01725A (available alnce 1971) Ordinary intermediate' Sprinkler Finloh: Brass F-.otao ' Tho ,prinl<ler lemperaluro roting Is ~ on 1h• deflect«. None 150 'F (65 •CJ White • Based on NFP .... 13. Other ilmlts may apply, ~ on 11nt loading, sprinld..-loc:ation, and other roqolrements d tho Authority Having Jurlsdction. Rofotto apocltlc Installation 1tandards. ' Tho katmedia1o IMnporalufo rating la av-for Sp,inkJor 8al0 Part No. 10284 only. Wrwlchftal -...... Spllnldor ~cap Flguro 1: ESFR P.-SprlnklorWronch 13e35W/8 Form No. F _060198 17.02.02 Rev 17.1 2-7/11" (74mm) Sprinkler 10214 Shown Flguro 2: ESFR Pondent Sprinkler VK500 Dlmenalona Page 3 of 6 '\IIKINC; TECHNICAL DATA ESFR PENDENT SPRINKLER VK500 (K14.0) The Viking Corporation, 210 N lnduatrlal Part< Drive, HHllng• Ml 49058 Telephone: 269-&45-9501 Technical Services: 8n..J84.5464 Fax: 269-818-1680 Email: t1tehavca@vlklngcorp.com Vl1H the Viking -lta for the lalalt edition of 1h11 tlchnlcal datl pogo: www.vlklnggrouplnc.com ,., ..... ca.tf(Uij .. ,._........,_ ...... "' ..... .., ... NPTThrud Nomlnll 0-.UL.ongth BIN Port 1111 81zo K-Flldor N_. IMI T ctn . .,.• lnchH mm u.a. --10284 1/KSOO ~-20mm 1,.0 -2-7/8 13 I A1. e1 11350 1/KSOO 31<" 20nwn -202 2-7/8 73 19655 1/KSOO 31,· 20mm -202 2-7/8 73 21360 1/KSOO -20mm -202 2-7/8 73 Apf>'O"OCI Tamponture Rating,, A-165 "F (7• "C) 8 -205 'F (96 "C) F-...... • Base part number shown. For complete part numbef, relar lo the price Hal i;:::..., - Uotlngo and Appn,yala" , __ IO_C __ I NYC' l YdS l LPCB A1 A1 A1 Appn,yod Flnloh 1-8-a A1,B1 A1,B1 [ar"1 A1 A1 'Melrtc:K-F"""'-'"-' •-pn,uun, ls,,_.... In bar._, _.,.il-..-ed In kPa, divido tho metric K-Fad0r shown by 10.0. ' This chan llhows Uttinga and appn,vala avallable ot tho time of pnnllng. Olhor approval• may be In proceaa. 'Refit to the latest atandarln of NFPA 13 and the latest VdS standards. 'lilted by U-LaborlltorlN me. fo, -In tho U.S. and Canada. • Acalpted for use, City of Now Yott< Dopam,onl of BYlldingt, MEA 89-92-E, Vol. 18. '(E Certiled, S-CUAP11.03/03, E~ of c:onlonrily 172s-cPl).tt0005, ETA-10/030II. &YLMI YIUDA Btevk:tmto!a· ~-CULi CMIDNllrlD ..... a.t 1--.1 ~~ :r-~3i~S:s~~~1~o==i"'~. ~ 1 lor-ln --tho la1ettappopriale NFPAttan- • Plo!ecllng --of-tjl9d!'ood moteriols up lo35ft(10.7 m) hlghln buldings-<Oft (122 m)hlgh ce;a,,gs-NO.,,_,_....,_ Iden. • NFP!'. 13 indlca!N tho [olow;ng for ESFR ~ oprinldero having a 1,.0 nominal K-Fac:IOr. Pooi11on tho dallm.lll< a maxim<.m ol 1'0 (356 mm) and a minimum of I" (152 mm) below tho c.ilng. • Tho minimum -of""""'-•-par~ Is 6-4 ft' (5.8 m') par NFP!'. 13. Maximum Roof or Celling Slope: 2 In 12 (167 mmhn or 9.5 degree•~ Spnnlller P-: ApprOYod for UM only In tho pandn ___ Algn tho de-poralW wffh tho celllng or root. &yotam Typo: Wet. tystamt any. Deflactor Dletance ftorn Wallo:,. lout•· (102 mm) from wah. and no mora 1han onH\1111 tho allowable ditWlC8 pam,lttod betwaen ap,lnkle<s. Ctearanca from Deft«tor to Top of Storage: At tent 36a (914 nvn). llulmum Dletanco __, 11pr1n•i.ra: Tho maJCimum •-of--pa, lprinkle< la 100 ft' (9.3 m')"'. • For buldlnga OYer 30 ft (9.1 m) high. apodng _,, lj)rinldera and/a, b<anch lines mu11 be from 810 10 ft (2.• 10 3.1 m)". • For building heighla up 1o 30 ft (9. 1 m), tho apodng alowed between--. and/Or btanch IIMl la 8 lo 12 ft (2.• 1o 3.7 m). pn,vidod tho a,ea COYOrod par aprinlder-. not axcood tho mulmum 100 ft' (9.3 m') elowod"". ~uu:!'"~,.~~ ~~1ion1 fromthommnumopm1<1orapaang ru1ooa1>ove. 10e1m1na1s--..Cl88tod Minimum NN ol c_, Tho minimum area°'""""'--par '4)rint<ler la 8' ft' 15.8 m'J. N.,_: W tho oallng la beam and girdef or panel -• lccata ll>flnldorl In the beya ,_ lhon urd« tho beamt. IMPORTANT: Atwayl refer to Buli.tln Form No. F _091U9 •car.and Handllng of Sprlnkle<s. Vl•lng ESFR Pendent Sprinl<lero .,. to be lnltllled In accordance with lhe lmMt edition of Viking technical data, the I-ltlndanll of VdS, NFPA, and any olhlf AulhorltlN Having JUMdlcUon, and alao with provllk>nl of _,,,men111 codel, ordlnancu, -etandards ,.,,.,,._ appl-. Form No. F _060198 17.02.02 Rev 17.1 '\IIKINC;® TECHNICAL DATA Page 4 of 6 ESFR PENDENT SPRINKLER VK500 (K14.0) The Viking CorporaUon, 210 N lnduatrlal Part< Drive, HHIJngs Ml 49058 Telephone: 269-&45-9501 T1tehnk:al Servlcaa: 8n..J84.5464 Fax: 269-818-1680 Email: tltChavca@vtklngcorp.com V11H the Viking -bstt. for the lataat 1dltlon of Ihle technical datl _, www.vlklnggrouplnc.com BIHPort N.,_. 1028' 11350 SIN VK500 1/KSOO .App1W111 Cllalt 2 (1111) ..., ...... ........,_ ..... "' .. Ctl.., ... NPTThrudSlzo Nominal K~actor OvenlN length lnchoo I mm U.S. I .-1c' ,,_ mm ~-20mm 14.0 2-718 73 ~-I 20mm I -I 202 2-718 73 Apf>'O"OCI y_,..,. Rallngo A· 185 'f (7• 'C) B • 205 'F (96 'C) F- li;S:_.:J FMApp<ov ... ,.. __ ,. ____ , A1.B1 A1,81 Apf>'O"OCI finish 1-lna ' -part -ohcwn. For oomplota part-.,_., 1ho price 11st. 'Melr1cK-Fact0r-shoo<lla-praa&Lnla-.rodlnbor.'Mlln_,.la-..odlnl<Pa,dlYldetho-1l:K-Fador"'-'by10.0. , This chart shows the FM Approval• available at the time of printing. Other approvals may be In process. ' FM Apprt,Yed u a quid< reaponse pandenl Non-1110,_ lj)rin-and allo FM Apprt,Yed aa a quldt respon1<1 pendent Slonlgo aprin-. Refer to Dellgn Cntaria below. -~ ... CMIDNllrlt ..... OIM2-..J FM AmrpyN BtAYlttrnl01il· 1. ~1/KSOO la FM-a a quick,_,.. pendant 9-~ aa lndlcatod In tho FM"""'°""' Guido. • For apacfflc opc,llcalion end -roqun,nenll. -...,. tho •-appllcal>le FM L-Prewr<ion Det.a -(1nctJdlng Oet.o -2-0andW). 2. Sprlnl<ler VK500 It llto FM Apprt,Yed n a quid< reaponaa ~ --sprWcler es lndicatad In tho FM Aj>proval Guido. • Forapacillc ~ and-lx>n --• ..-.oa tho lolnt aplJlicablo FM Loa_,.,,, Dot.a Sheets (lncfl.Cling Dot.a SM« 2-0). FM Global Loa PreYemfon Do1a --~ relallng 10. but not-lo:,,,.,.,,..,, watar a.q,ly requinlmonla. h)'<hufic dealgn. ceiling tlopa --· -and mulnun-apadrG. and -dttanco below 1ho .-.g. NOTE: Tho FIi IMUllallon gvldoffnaa may dlffor ftorn c\Jlua and/or NFPA -.ta. IMPORTANT: Always rater to Bulletin Form No. F _091699 • Care and Handling of Sprinklers. Viking ESFR Pendent Sprinklers are to be Installed In accordanca with the latHI edition of Viking tltChnlcal data, the la1Nt eppllcable FM Global Lou Prevention Data Sheets (Including 2-0 and 8-9), the lalnt standard• of VdS, NFPA, and any other Authorities Having Jurisdiction, and also with provision■ of govemmental codH, ordinance•, and atan• darda whenever applicable. Form No. F _060198 17.02.02 Rev 17.1 Page 5of6 'JIKI~® TECHNICAL DATA ESFR PENDENT SPRINKLER VKS00 (K14.0) The Viking Corporation, 210 N Industrial Part< Drive, Hastings Ml 49058 Telephone: 269-$45-9501 Technical Servlcee: 877-384-5484 Fax: 269-818·1680 Emall: tachavca@vlklngc0fl).com Vlalt the Viking webalta to, the I-edition of thlt t.c:hnlcal data page: -.viklnggrouplnc.com 4. INSTALLATION Viking aprtnklers a,. manufactured and tffi.d to meet rtgld rsqulremanta of the approving agency. The sprinklers .,. clfflgned to be Installed In ac:cordance with recognized Installation standard■. System clfflgn muat be balled on ESFR design guidelines described In the latest edltlon of Vlkln~lltchnlcal dolt, OflPIICable FM Gfobal LOH Prevantlon Data ShHlt, the latest NFPA Standards, the I-t atandenls of dS) Schadenverhlllung, the Authorities Having Jurtadlctlon, and also with the provisions of govammental codes, onl n■ncff, and atandanle whenevar applicable. Deviation from the sltndanls or eny ■Iteration to the sprinkler aflar K IHVff the factory Including, but not llmlted to: pelnUng, platlng, coating, « modification, lMY ,.nder the sprinkler Inoperative and wlU automaUcally nuUlly the approval and any guar• anllte made by The Viking CorporaUon. A. Spflnlders must be handled with care. They must be stored In a cool, dry place In their original shipping container. Never lnotall sprtnklera lhat have been dropped o, damaged In any way. Such spnnlders should be destroyed lmmedtately. NOTE: Wet pipe oystems must be provided with adequate haat. B. The sprinklers must be Installed aftsr the piping Is In place to prevent mechanical damage. Bef0<8 instaMlng, be sure to hava the appropriate sprinkler model and style, wllh 1he conect oo1flce size, temperature raUng, and response charactaristlcs. C. Wl1h 1he sprini<ler contained In 1he plastic protective cap, apply a small amount of pipe-joint co,npound o, tepe to the male threads ooty, while taking care not to allow a build-op of compound In the sprinkler orHice. D. Un ONLY aprlnkler wranch 10:ZSSWIB or 13tl35WIB (ahown In Flgu,. 1) for lnetalllng ESFR Sprinkler VK500I With the sprinkler contained In Iha protactlva cap, Install the sprinkler onto the piping by applying the sprinkler wrwnch to the aprtnkler WN:nch flab onty, whH• taking "'9 not to damap the aprlnkler operating parts. • DO NOT use any other type of wrench, as this could damage 1he unit. • DO NOT use the sprinkler deflector o, fusible element to start o, lhread the sprinkler Into a fitting. • DO NOT exceed 50 fl lbs. of lorque (hand tight plus approximately two full turns with Ille wrench) to lnslaN these sprinklet1. Higher levels of torque may distort Ille sprinkler Inlet with consequent leakage or lmpalrmenl of the sprlnkler. E. Aller Installation, Ille enllre sprinkler systam must be tested. The last must be conducted to comply with the Installation Standards. Make sure 1he sprinkler has been properly llghtened.11 a lhroad leak occura, nonnally Ille unit must be removed, new plp&-jos,t compound o, tape applied, and then relnslalled. Thia Is due to lhe fad lhal when Ille joint seal Is damaged, Ille sealing C0ITlf)OUnd or tape Is washed out of Ille Jolnl Immediately replace any damaged units, using 1he special sprinkler wrench only. F. Altar lnatallallon and testing and repairing of •II Iuka, ren,ove tho protKtlve c■P9 from Iha sprlnklera. DO NOT uae any type of tool to remove Iha cap. Ramove the cap by hand: tum tt slightly and putt tt of! Iha sprinkler. When removing caps, uae ca,. to pnvent dlslod9lng or damaging lprlnki.r ejec:1or aprlng and fusible elam...L THE CAPS MUST BE R!MOVED FROM SPRINKLERS BEFORE PLACING THE SYSTI:M 1H SERVICE! G. System design must be based on ESFR daslgn guldollnes dosatbad In applicable FM Global Loss Prevention Data Sheets, 1he latest atandan!s of (VdS) SchadanverhOtung, Ille National Fire Protactlon Aasoclation, and 1he Authorities Having Jurlsdlctlon. All requlrernenla of recognized sprlnkler aystern dsslgn standards apply to oystemt utilizing Vlklng ESFR Pandsnt Sprinklers. NOTE: Viking recommenda lnstanlng one style ol aprlnklera (•lther pendent or upright) throughout ESFR systama. H-,, provided the fusible elemen19 are Installed within tho dlatanca below the calling allowed by the lnatallaUon standards, and whan acceptabl• to the Authority Having Jurtsdlctlon, Viking conalders tho practlca of mixing upright and pendant ESFR sprinklers to be accaptable. 5. OPERATION During fire conditions, Ille heat-sensitive fusible element assembly disengages, releulng Ille seat and spring aaaembllea to open the waterway. Water flowing through Ille sprinkler orifice strikes the sprinl<ler deflector, forming a uniform spray pattem to suppress Ille fire. fo,m No. F_060198 17.02.02 Rev 17.1 'JIKI~® TECHNICAL DATA Page 6 of6 ESFR PENDENT SPRINKLER VKSO0 (K14.0) The Viking CorporaUon, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technleal Services: 877-384-5464 Fax: 269-818·1680 Emall: techavca@vfklngcorp.com VlsK tho Vlklng-balta to, the latest adltlon of this technical data page: www.viklnggrouplnc.com 6. INSPECTIONS, TESTS AND MAINTENANCE ~~l=•~n-==~~j"..=nlng u~=: ~=.:~~!r =~'".!'~::=~~ of sprinkler aystems. In addition, IN ~orltlff Having Jurisdiction may have additional malntenanca, testing, and lnopecUon ,.qul,...,ente that muat be fol-. A. The aprlnklera must be lnapected on a regular besls for C0m)8lon, mechanical damage, obatructlona, paint, etc. The frequency of Inspections may vary due to corroslvo atmosphere, water supplies. and adMty around the device. B. Sprinkle!$ that have been palntad 0< mechanlcalty damaged must be replaced Immediately. Sprinklers showing signs of 00<· rosion shat be tested and/o, replaced Immediately as required. Installation atandatds require sprinklers to be tested and, ff neceasary, replaced aftsr a specified term of service. For Vlldng ESFR Pendent Sp,lnlclora, refer to the lnstaftatlon Standards (e.g., NFPA25) and the Authorities Having Jurisdldlon for the specified period of time allsrwhlch testing and/o,replacement Is required. Sprinklers that have operated cannot be reassambled o, reused, but must be replaced. When replacing sprinklers, use only new sprlnlders. C. The sprinkler discharge pattem la crttlcal for proper fire protection. Therefore, nolhlng should be hUng lrom, attached to, o, otherwise obstruct the discharge pattern. All obstructions must be Immediately removed or, ff necessary, additional sprtnldera Installed. D. Whan replacing existing sprinklers, 1he system must be removed from service. Refer to the appropriale system desaiptlon and/ or valve lnatructlona. Priof to romovlng the syotem from service, notify all AIJthoritiea Having Jurisdiction. Consideration ahould be given to employment of a fire patrol In the affacled area. 1. Remove the system from service, drain all water, and relieve all pressure on Ille piping. 2. Using Ille special sprinkler wntnch, remove Ille old sprinkler and Install the new unll care must be taken to ensure that Ille replacemenl sprlnkler Is 1he proper model and style, with the correct oo1flce llze, temperature rating, and response charao- laristico. A fully stocked spare sprinkler cabinet should be provided for lhis purpose. 3. Place the systam back In l8!Vlce and secure al valves. Check 1he replaced sprinklers and repair aM leaks. E. Sprinkler systems that have been subject to a fire must be returned to service as soon as possible. The entire system must be Inspected for damage and repaired o, replaced as necessary. Spflnklerl Iha! have been exposed to C0m)8iva products of combustion, bU1 have not operated, should be replaced. Refer lo 1he Authorities Having Jurisdiction fo, minimum replacement requirements. 7. AVAILABILITY The Vll<lng Model VK500 Sprinkler Is avaffable lhrough a nelwori< of domestic and international dislributoni. See The Viking CO<poratlon web site fo, Iha closest distributor o, contad The Viking CO<poratlon. 8. GUARANTEE fo, detaUs of warranty, refer to Viking's current list price schedute o, conlact Viking dlrectly. fo,m No. F _060198 17.02.02 Rev 17.1 Replaces fo,m No. F _060198 Rev 16.1 (Addad CCCF approved sprinkler.) Firelock4D V34, K8.0 Model V3428 Quick Response Extended Coverace/llct,t Haurd (ECLH) Pendent and Recessed Pendent I Approols/l.lstinp: ·i· $H lf•-tM1<: P,ibt-cetloo 10 01 'or mor, ~aih -Description: These Model V34 ECLH sprinklers ara designed with a K8.0 orifice size and provide added coverage at normal light hazard operating pressures. Each sprinkler is cast with a hex-shaped wrench boss to allow easy tightening from many angles, reducing assembly effort. This sprinkler Is available In various temperature ratings (see chart on page 4) and finishes to meet many design requirements. c-race Extended spray coverage is up to 400 square feet (37.2 sq. m) per NFPA 13. Jobo'Owner System No. t location -Contractor Submitted By Date I Technical Specifications: Models:V3428 Style: Extended COYefage/ Light Hazard • Pendent, Recessed Pendent Nominal Orifice Sia: •~'/14 mm K Facblr. 8.0 lmp./11.5 S.I. 1 ✓-IC\aullC' 40.78 Nomlnal Thread Size: l4' NPT/20 mm BSPT Mu. Wootd,-Pressure: 175 psi/1200 kPa Factory Hydn,sbtic Test: 100% 0 500 psi/3450 kPa Min. Operating Preuure: 7 psl/48kPa Tempera11n Ratlnc: See chart 1 For K-factor whtn prnsure 11 measured in Bu, ~ S.I. unit& by 10.0. ~r-,~ J,,l1 ··,._j Exaggerated for clarity Enp,eer Spec Seeton Paragraph l Approved ~ Date 1 victaulic.com I Sprinklers I Firelock" I V34, K8.0 I Publication 40.78 40.78 &496 Rev~ Updated 01/2015 0 2015 Vic:tau6ic Company. All fiahts rewved. 1 ~ctauhC' victaulic.com I Sprinklers I Firelock" I V34, K8.0 I Publication 40.78 -ialSpedfiullons: Pendent Deflector. Bronze per UNS C22000 Bulb: Glass with glycerin solution Bulb Ncmlnal ~: Quick Response, 3.0 mm Load Screw: Bronze per UNS C65100 Pip Cap: Bronze per UNS C65100 Sprillll BeryHium nickel SUI: Teflon' tape Frame: Die cast brass 65-30 l..odpment Sprinc: Stainless steel per UNS S30200 ApprovalslUstlnp: APPltOYALSIUSTINGS :::=,, l Nomlna! K FKtOr ~ Nornlnal K Factor S.1.1 -----t- ~- Deflector Type Approved Tffl'IC)erature ] R1Uft9S P/C' 0 dJl..s -v.,.2, '13428 17/32' 14 8 \1.5 Qukk Pendent 17/32" r-~ 11.5 ~ Reas~Pffldent Aop,-d T•-" Rotlnp r,c• • • l3S"f/S7-C 1SS"f/61"C 17S"Ff19"'C loo-FtWC 1lS"f/57"C 1SN16rc 17S"ffl9'C lOO"f/9J-C Ustlnp and apprO¥al n of pnnrinc. Not al letnOCf'ltut• mine combinations a,e, Appro¥eG o, lb.Rd. Check VlctalAic for specik combwiations. ' Fo, K-FldDr wtlet'I pressure Is rntH1¥ed In Bar, m.Mipty S.I. unl1• bf 10. • Ulhll'lal1rdonty. Accessories: Installation Wrench Open End: V34 Recessed: V34 Sprinkler Finishes: Plain Brass Chrome Plated White Painted Custom Painted VC-250' 1 T ef:on Is • relistered tr-.dtmtr1t of Dupont Co. 1 Ul lilted tnd FM ApptOYeO to, ccm>slon resm:tnce. Dimensions: ,~11 Cdlng ile finfshedSur'ace 1wrnt ~ ; ~~--l1N/3~rrm FhiSNdSurfKt' ,·,~=1 2Smm~Cdngrk . Fhbhfc Suface ,v.-1 ... ~ ; 1 •:-=v4t ,,,,..c..., 1W/35mm ~shedSurfKt l 40.71 8496 RC'f A Upd,ted 01/2015 0 2015 VlctalMc Company. Al rflhts reserved. ✓~ul;c' victaulic.com 2 victaulic.com I SprinkleB I Fireloc,.-1 V34, KB.0 I Publication 40.78 11-,,Slze: Sptt-. ............. ---,--¥3421 -Size Flow ..... End s,,,1nklor -. ... GPIIUU'M PSUl<Pa ft. I ft. Ul Ul m1m ~ 16X 16 ,. 10A 4.JXU .. i n.1 11X 11 n I 17.0 s.sxs.s 125 ~ 117.2 20X20 40 25.0 6.1 X6.1 1SO 171.4 Distribution Pat12m5: MooelsV3428, KS.O EClH Pendent and Recessed Pendent Ofsttlbutlon Pattefm-TraJectory .:. ··-··-....... ~:.··········• .. '··, ·-.. ··, ·· ... ··, ·· .. ··,.. ·· .. '··, • ....... ··,. \ ·, \ ··,. ·\. -Vlo421·0lti NOTES: .. ... ----LO ,.. ,r A..DtlalhoWnil~andUl"l_..,dutlocitffflncHWlinllllltiOn. ·, .. \ \ ,. .,., .. .. .,.. ...... """ '""' 1k.1Ulil ...... 1S1AL'M 8. ThlN._,. ..... ~~toa,-welJir&lnd.....,._..PltW'ASb'ltleNIOIC-'tc'ltadcfnux:11;~~ ~•p,or,,ded• ntorl'rlldan kwe,&a inMOiil"IOOllr\.d:n'llsomkknand lhclUld rd be~asnwinun~~n;er; kiri1sC.llldol\. "-''111he~ NFPA N.lilbw fhCodtorhAuthatllyHaw\i.iu11dc:tio"I tar apedffc.Warmdan ,aprdina~ t,pldrw.,...,,_lnd .,_olOCM!'ll'niqui,lmentl. Fal.N'llkt,w tneM~caud~ltt.ctlhe perlornwuolthe ~ anc1wl'o'Oldal unr.,. Appto,wlanc:I Wlrrantles. C. Al p,tlam&arw 1)'fflfflllVICIII lob~ olthl ---,,, 40.71 M96RewA i.Jpdacd0l/2015 O2015\llctJIAc~.Allr'ctllSraened victaulic.com 3 ✓-iCtaulic' V1ctaulic.com I Sprinklers I Flreloc,.-1 V34, K8.0 I Publication 40.78 Ratlnp: All glass bulbs are rated for temperatures from -65'f (-54"Cl up to those shown in adjacent table. ~ T_..... -OnlJnaty Ordinary -" - 1--"Frc M- -Jc --Gia .. Part T--T-- --.. -Cola, 13M/5rc 1°"'38"C Orange 1 Ss-fl'W'C 100'f/31'C Red 17s-fl7'9'C lso-F/65-C: Y.tklw 200"f/9~ 1so-FJ6.VC GtHn Available Wrenches: I -· -- Open End VJ< -VJ< VJ< ... _ ,.,, ~ • Nw1J1 rtad and undtr'ltlnd lnltalalioft. ure, and malntenanu mtructlon&. suppllad with uch bn al tprift• __ ........,. __ .. .,..,.,..._._ • __ ..,..,,s.u.. ... 1oo1..-11an. • Dop,o,surizoondckalotllaplplnc-bo!M--lolnttall,-.oradjutlMfYlctautlc:piplltl -• ln&tallltton rvt11, eapeclalfy thou ,owemln,: ob&tructlon, must be atnctly ~ • P-111, pllllno, .,.,,, ........... .,....,_. _tllan that~ .. Ylctauk) lo ... .-. C F-lo--lnltndlonocouldNtultlnM!lau1-ln)wy ____ ,,,__.,,..,.._,.,_tllalh---ond-ln.,._--.-.Fo, ml...,_,...,_,,.. ... .,.pac11on~-lotllaaonnt NatioNIFkw..,__AuodallGnpam- phllt ... , _ ... .,._.,_.,. ...... In -. the IIUthtrllJ """'"')uri,dlctlon - -----ond-,............,.muatbe-. H '°" nNd --copies of !ht. puOtlclllon, or H '°" -an, -about Illa..,_ ,_ of 1h11 • -contact YlclMlc Wa<1d --• ,.o. .._ 31, Easton, -18044.0031 USA. T...,,.,_, 001-610-5!19-3300. -~--.llcl~blffllOt•n.1. V'lc-.-..nr.i.o«,.__,_Sor....,. -Tllll....-.,,:tlflllllll--.c:t-.ndtir'k&ukw•v~~Alllf"OIIUCII .... ~end~SftNIWr..Pf'Ddl,,d,-,-~ TNI~.,.._ ll~~ucti..-irlVidlUlt,-klcllW~~_, ...... ON,end1t......,..lnl'Oflorffllll11n01,1J ...... el~ -"'-•tt1eW,,,,..,.,lltdlonoll1llevr.,.iPTtct1.111wceo1uctV1ctNlctwdltall. •t1alMldadlnllCConSllu--~Vlc:taAtfflllllellol.....,.inMNc:tor&. YlttaAc~lhl-lDct.,.llf-..cl~dailnJIMIIMOWd ea..,_,.MlflOIIIIMiiee-,Wt.._A~ltll:a,.tl,Onl, -YlcUAl:9t,...WadlltOef'WllolV!cbult;eom,.,,,, 40.71 8-t96RINA lkJO,tceCI0l/2015 O20J5Vlct.A::Comp,ar,r.Alrilhtsresienied. ~taulic' victaulic.com 4 As the leading supplier of steel sprinkler pipe, we understand that there are no second chances in fire suppression. You need products of enduring quality and exceptional strength-plus reliable service. You need Bull Moose. Wei ht (lb/ft) 1.461 FIiied Wei ht (lb/ft) 1.860 1.00 s per Lift 70 eight (lbs) 21' Jen hs 2,148 eight (lbs) 24' !en 2,454 el ht (lbs) 25' len 2,557 EDDVT~READ 40 ADVANtAGES: • UL list:11 (US & Canada) and FM:approved ASTM Ap s and A795 Type E, Grade A Certified ,. • c9mpli,s with NFPA-13, 13R and :14 lnpustrY!-leading hydraulic char kteristics • CRR of .0 and·greater • A\l pipe NOT weld tested 2.070 Z.754 1.00 51 2,217 2,534 2,639 sive maker of Reddi-Pipe® • RED OR BLACI< PAINTED PIPE. II c®usLISTED ~ APPROVED 1.654 2.547 3.468 1.00 44 2,353 2,690 2,802 Z.123 3.308 4.842 1.00 30 2,084 2,382 2,481 OTHER BENEFITS/SERVICES: , We have the most stocking locations in the industry, for best delivery and availability , Plain end or roll groove , Eddy Guard 1r bacterial-resistant internal coating • Custom length options Hot dipped galvanization Reddi-Pipe® red or black pipe eliminates fit:ld painting • Compatible for use in wet. dry, preaction and deluge sprinkler systems • The only maker with EPDs (to help earn LEED points). IJ.) NFSA NFPA' ----- .- OLC□-www.tolco.com ' a hi,rnd orNIBCD' Revision 5/24/2001 Fig. 200 -"Trimline" Adjustable Band Hanger Size Range -1/2" thru 8" pipe Material -Carbon Steel, Mil. Galvanized to G90 specifications Function -For fire sprinkler and other general piping purposes. l{nurled swivel nut design permits hanger adjustment after installation. Features - • (1/2" thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. 'Hanger is easily installed around pipe. (2 '/," thru 8" Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. 8 A / ) B A Approvals --Underwriters' Laboratories listed (1/2" thru 8") in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW-H-171 E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. 1,;, THR,. 2 INC:H Pl"'F :! 1 :2 I HRv B INCH f'lf'I: Maximum Temperature -650°F Finish -Mil. Galvanized. For Stainless Steel materi- als, order TOLCQTM Fig. 200WON. Order By --Figure number and pipe size Dimensions • Weights Pipe Rod Size Size Inch Metric A B 1/2 3/8 8mm or 10mm 3'/a 2¼ 3/4 3/8 8mm or 10mm 3'1. 2'1, 3/8 8mm or 10mm 33/, 25/a 1¼ 3/8 8mm or 10mm 3¾ 2'1, 1 '/, 3/8 8mm or 10mm 3'/, 2'1, 2 3/8 8mm or 10mm 4½ 3 2½ 3/8 10mm 55/a 4'/, 3 3/8 10mm 5'1, 4 3½ 3/8 10mm 73/, 5¼ 4 3/8 10mm 73/, 5 5 1 /2 12mm 9'1, 6'/, 6 1/2 12mm 10'/a 6¼ 8 1/2 12mm 13'/o 8¾ -:- Max. Rec. Approx. Load Lbs. Length 400 11 400 11 400 12 400 13 400 14 400 15 600 27 600 29 600 34 1000 35 1250 66 1250 73 1250 136 Main Office/Manufacturing Facility• DI'• ,anp<Ol1 A\'~ • Coiom. r:1I q2~Ig • r11 ~ffl /3/ o"!J9 • ra,: !109 /JI G3J,J Customer Service • ~(i.J l'~G 1,200 www.tolco.com / / _,.-- ---- ' OLc□· www.tolco.com : ,1 brand of NIBCO' Revision 5/24/2001 Fig. 98 -Rod Stiffener Size Rangei -Secures 3/8" thru 7/8" hanger rod Material -Carbon Steel Function --Secures channel to hanger rod for vertical seismic bracing. Finish -Electro Galvanized Note -Available in HOG finish or Stainless Steel materials. Order By --Figure number Thread R.od Cut to Length I res 3/8" thru 7/8" rod in Dimensions • Weights rtts Material -Carbon Steel Maximum Temperature -750°F Finish -Plain Note -Av21ilable in Electro-Galvanized and HOG finish or Stainless Steel materials. Order By --Figure number, rod diameter, rod length and finish Fig. 1 OID -All Thread Rod Full Lengths Size Range -Secures 3/8" thru 7/8" rod in 1 O' lengths Material -Carbon Steel Maximum Temperature -750°F Finish -Plain Note -Available in Electro-Galvanized and HOG finish or Stainless Steel materials. Order By -· Figure number, rod diameter and finish Dimensions • Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size G50°F 750°F Wt./100 1/4 240 215 12 3/8 610 540 29 1 /2 1130 1010 53 5/8 18 10 1610 84 3/4 2710 2420 123 718 3770 3360 169 4960 4420 ·222 1 'I. 8000 7140 360 1 '/, 11630 10370 5'10 Rod Size 3/8 1 /2 5/8 3/4 7/8 II Main Office/ManulaclUring facility• 13/o 5ar1psnn /Ive • Cc>tcrn C/\ 92~19 • r11 m Ill 0599 • rn, 900 /310330 Customer Service • s,:~ l(Ui 1,:?06 www.tolco.com Max. Rec. Load Lbs. For Service Temps 650°F 750°F 610 540 1130 1810 27 10 3770 1010 1610 2420 3360 .------..,_ -8007957 GST 10 X 8020957 SWG 10 X 8008957 GST 20 X 8068925 GST 20 SS X 8010957 GST 30 X 8009925 GST 25-380 X 8022925 SWG 25-380 X 8021957 SWG20 X 8073925 SWG 20 SS X 8139957 SH GST 20 X 8141957 SH GST 30 X 8140957 SH GST 20 SS X 8142957 SH GST 30 SS X -8038957 DSTR 1 X 8037957 DSTR 1-1/2 X 8039957 DSTR 516 X 8045957 DST 516 X 8046957 TEK 50 X 8055957 SWOR 1 X 8056957 SWOR 516 X 8054957 SWOR 1-1/2 X 8137957 SH OSTR 1 X 8150922 XP 20 X 8153922 XP 35 X -8059957 CST 20 8061957 swc 20 FM CPVC 1-1/2 300 CPVC 1-1/2 300 2-1/2 850 2-1/2 850 4 1500 4 1500 3-1/2 -4.-1500 2-1/2 -3** 1250 2-1/2 1250 3 1050 4 1500 3 1050 4 1500 4 1500 4 1500 4 1500 4 1500 4 1500 4 1500 4 1500 4 1500 4 1500 2 750 3-1/2 1250 ®us LISTED 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 0.035 0.035 0.037 0.188 0.250 0.037 0.037 0.037 0.035 0.027 0.043 X X X X X X X X X X X X X X X X X X X * SWG 25-:380 Maximum pipe size in composite wood joist allowed by UL is 3-1 /2" SWG 25<180 Maximum pipe size in wood timber or joist allowed by UL is 4" ** SWG 20 Maximum pipe size in composite wood joist allowed by UL is 2-1/2" ** SWG 20 Maximum pipe size in wood timber or joist allowed by UL is 3" UL and FM tests were performed in compliance with NFPA-13 Standards. 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 1475 1475 1475 1475 1475 1475 1475 1475 1475 1475 1475 1475 1475 1475 1475 1475 1475 1475 1475 1.5 1.5 1.5 1.5 1.5 1.5 0.1 050 0.1050 0.1050 0.1875 0.1875 0.0600 0.0600 0.0600 0.1050 0.1050 0.1050 3000 PSI 3000 PSI • 1T~JJ8uildex Fastening requirement: 5 times weight of water filled schedule 40 pipe plus 250 pounds. www.itwbuildex.com 800-284-5339 SSS26 "'G;S® TECHNICAL DATA 1 of 3 HOLE CUT SYSTEM MODEL V-72:J SADDLE LET MECHANICAL TEE The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: STT-384-5464 Fax: 269-a18-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION VGS-Model v-n3 Saddle Let small mechanical tees are available in sizes 1-1/◄• ttvough 2-112·. The Models V-n3 mechanical tees provide an easy take-out of a branch outlet without the need for wekfing. VGS• Mechanical Tees are manufac- tured at l$09001 certified facilities an are designed to confonn lo ASTM and other standards 'where applicable. Threads are NPT per ANSI B1.20.1. 2. LISTINGS AND APPROVALS c@)us Guide No. VIZM <8> Class 1920 3. TECHNICAL DATA Specifications: Maxiroom worl<ing pressure: 300 psi (21 bar) Ductile iron conforming to ASTM A536 Grade 65-45-12 Standard black finish The latest VGS• Tec.hnlc:at Data can be acessed at http:Jlwww.vikinggrouplnc.com. Scan to visit our Mobile website: http:/Mkinggroup.mobilp/4637• Hot dipped Zinc gatvanized versions are availab~ (conforming to ASTM A 153); when ordering, add a -o• suffix to the Model number. Rubber compound EPDM Grade E conforming to ASTM 02000, AWNA C606, NSF 61 and IAPMO. Nuts and Bolts: Zinc plated, Carbon Steel conforming to ASTMA183 Grade 2 (UNC nuts and bolts are a silver chromate color and ISO are a gold chromate colot) 1.25x 1 (32x25) 1.Sx0.5 (40x 151 ilio.75 14'>X2D) 1.Sx-,- [4Ox25) 2xcfs- (S0x 15) 2 X 0.75 1sox 201 2x1 [SOx 25) 25rtS [6Sx 151 2.Sx0.75 [65 x 2Dl 2.Sx 1 [65 X 25) 1.18 130) 4.37 1111 4.37 111 1.0 (0.45) 0.9 (0.41) 0.9 _J_0.41 0.9 10.41 0.9 (0.41 0.0 10.41 1.0 (0.45) 1.0 (0.45 1.0 (0.45: 1.0 (0.45) "'t1ollt oiametars are sug98Stad hole saw diameters... -r. Take-out (Center of run to end of pipe to be engaged) Form No. F _110515 16.12.06 Rev 16.1 Replaces Form No. F _ 110515 Rev 15.1 (Added K-factor limil table and flow data) "'G;S® TECHNICAL DATA 2of3 HOLE CUT SYSTEM MODEL V-72:J SADDLE LET MECHANICAL TEE The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-a18-1680 Email: techsvcs@vikingcorp.com 4. HOLE CUTTING The hole-a.rt method of pipe preparation is required ¥when using mechanical tees, mechanical aosses, and sadd~ts. The method of pipe preparation requires the cutting or drining of a specified hole size on the centerline of the pipe. Atways use the correct hole saw size as shown this data sheet and never use a torch for cutting a hoJe. After the hole has been cut all rough edges must be removed and the area within 5/8~ (16 mm) of the hole should be inspected to ensure a dean smooth surface, free of arr-/ indenta-- Uons or projedions that could affect proper gasket sealing. The area within the •A• dimenSK>n should also be inspected and must be free tor dirt. scale or any imperfection that coukt affed proper seating or assembly of the fitting. 1A1 j i : ,,a, : ~--+~~H--· ! ',, .. / ! w ,..,~- 5. INSTALLATION NOTES: Use a wrench to hold the threaded out!et in place: when instaUing the sprinkler. Tighten the nuts evenJy. Form No. F_110515 16.12.08 Rev 16.1 Do not install sprinkler directJy into Saddle-Let with 1• outlet. Hole Gasket ~ Threaded~ outlet "" Nuts _/lfP, 1 Sprinlder - c:-.,-... ".,...,,. ~-.a_,,_ '_., , __ ._.,_...., __ ~ ------·--•• -···--- "'<GS® TECHNICAL DATA 3of3 HOLE CUT SYSTEM MODEL V-723 SADDLE LET MECHANICAL TEE The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-S501 Technical Services: 877-384-5464 Fax: 269-ll18-1680 Email: techsvcs@vikingcorp.com 6. FLOW DATA V-723 V-723 V-723 Fk:>w test data has sho'M"I that the total head loss between point A and B for the fittings can be expressed in terms of the pressure difference across the inlet and branch. The pressure difference can be obtained from the relattonship below. 1.5 2.5 FormNo.F_110515 16.12.08Rev16.1 l 27 6· 27 38 Formulas for Cv Values: .1.P=a2 C,,' O=C,,X..f6P W'lere: Q • Flow (GPM) 6P s Pressure Drop (psi) C..,=-Flow Coefficient Replaces Form No. F _110515 Rev 15.1 (Added K•factor lmit table and flow data)