Loading...
HomeMy WebLinkAbout2856 WHIPTAIL LOOP; ; FPC2019-0059; PermitPERMIT REPORT Fire Permit Print Date: 02/29/2024 Job Address: 2856 WHIPTAIL LOOP, CARLSBAD, CA 92010 Permit Type: FIRE-Construction Commercial Work Class: Parcel#: 2091201400 Track#: Valuation: $915,297.00 Lot#: Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Project Title: Project#: Plan#: Construction Type: Orig. Plan Check#: Plan Check#: Description: CAMSTON WRATHER -SPRINKLER Tl (65 HEADS) Applicant: EPIC FIRE PROTECTION INC ADAM BOISVERT 765 TURTLE POINT WAY SAN MARCOS, CA 92069-8126 (760) 310-6122 FEE FIRE NFPA 13 or 13R System 7 -100 heads Fire Sprinklers Total Fees: $553.00 Total Payments To Date: $553.00 ( City of Carlsbad Permit No: FPC2019-0059 Status: Closed -Fina led Applied: 03/13/2019 Issued: 04/02/2019 Finaled Close Out: 10/01/2019 Final Inspection: INSPECTOR: Salcedo, Felix FPContractor: EPIC FIRE PROTECTION INC 765 TURTLE POINT WAY SAN MARCOS, CA 92069-8126 (760) 310-6122 Balance Due: AMOUNT $553.00 $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 442-339-2665 I Inspections: 442-339-2660 I www.carlsbadca.gov MATERIAL DATA SUBMITTAL CAMSTON \VRATHER T.I. CARLSBAD, CA EPIC FIRE PROTECTION, INC. 765 TURTLE POINT \VAY SAN MARCOS, CA 92069 (760)310-6122 FM(760)798-0556 L ,..~ .. '" BE ···-----~"'" FIRE SPRINKLER CORPORATION QUICK R ESPONSE AUTOMATIC SPRINKLERS GL SERIES UPRIGHT • PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) DESCRIPTION AND OPERATION The Globe Quick Response GL Series Sprinklers are a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element This provides sprinkler operation approximately six times faster than ordinary sprinklers. While the Quick Response Sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard spray sprinklers are specified when allowed by the applicable standards. It offers the additional feature of greatly increased safety to life and is available in various styles, orifices, temperature ratings and finishes to meet many varying design requirements. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction. The heart of Globe's GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb ~ increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern depending upon the deflector slyle used. TECHNICAL DATA • See reverse side for Approvals and Specifications. •Temperature Ratings -135°F (57"C), 155°F (68°C), 175°F (79°C), 200°F (93°C), 286'F (141°C) •Water Working Pressure Rating -175 psi (12 Bars) • Factory tested hydrostatically to 500 psi (34 Bars) •Maximum low temperature glass bulb rating is -67"F (-55°C) • Frame -bronze • Deflector -brass • Screw -brass • Lodgement Wire -stainless steel • • Bulb seat -copper • Spring -nickel alloy • Seal -teflon • Bulb -glass with alcohol based solution, 3mm size QUICK RESPONSE UPRIGHT CONVENTIONAL QUICK RESPONSE PENDENT VERTICAL SIDEWALL QUICK RESPONSE HORIZONTAL LPC/CE SIDEWALL HORIZONTAL SIDEWALL •SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING CLASSIFlCATION ORDINARY INTERMEDIATE HIGH AVAILABLE SPRINKLER TBIPERATURES 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 JULY 2012 A-20 BULB COLOR ORANGE/RED YELLOW/GREEN BLUE N.F.PA MAXIMUM CBUNG TEMPERATURE ~ • FAX989-846-9231 BULLETIN GL5615, REV. #9 ' QUICK RESPONSE AUTOMATIC SPRINKLERS GL SERIES UPRIGHT. PENDENT• VERTICAL SIDEWALL HORIZONTAL SIDEWALL • CONVENTIONAL (OLD STYLE) SPECIRCATI0NS NOIIINAL "I<" FACTOR THREAO SIZE LENOTH' FINISHES 2.8 (39 mell1c) 42 (59 metric) 5.6 (80 metric) 7.6 (111 metric) 8.1 (116metric) MIET'RIC COWERS IONS AREAPPROXltMT£. 1 HORIZONTAL Sl>£YIW.L SS 2 llfl8". 1 FINISHES AVNlASLE ON SPECIAL ORDER. 112"NPT 2 1/4" (5.7cm) faclD<y Bronm 112"NPT 2 1/4" (5.7cm) Ct-rome 112"NPT 2 1/4" (5.7cm) Wite Polyesler ~ 112"NPT 2 1/4" (5.7cm) Black Polyester .a.a 3/4" NPT 2 7/16" (6.2cm) 1 AVA&.ABLE AS dJlJ.-. LISTED CORROSION RES&STAHT WHEN 6PECIFED ON ORDER. APPROVALS 61YLE 61N K HAZAAD' 13S"f 1$'f 175"1' ZIJ'f all1'f clALs FIi lPC CE ~C-008 IIOOEI. fAClOR S7'C ..-c 7V"C llJ'C 141-C MEA 101.QZ-C G121115 2.8 U< X X X X X X ---X GlCl15 <4.2 U< X X X X X X ---X LPRIGHT Gl5815 5.6 lffllH X X X X X X X X X X GU!111S 18 lffllH X X X X X X ---X Gl.8118 8.1 lffllH X X X X X X X X X X Gl2llll1 2.8 U< X X X X X X ---X GU:11>1 •. , LH X X X X X X ---X PEMlElfT Ol.5lll1 s.a lffllH X X X X X X X X X X GU101 18 lffllH X X X X X X X --X GlB1Cll a, lffllH X X X X X X X X X X IIEJITICAI. Gt5B32 5.6 LH X X X X X X X --- SIJEWALL' GLl133 a, U< X X X X X X ---- Gt""5i 2JI LH X X X X X X ---X t«JAllDNTAL Gl<Z2!1i <4.2 LH X X X X X X ---X SDEWAU. Gl!1!21ll 5.6 lffllH X X X X X X X --X Ol.5621> 5.6 lffllH X X X X X --X X - GLl127i a, LWOH X X X X X X ---- C0N\IEllllOIW. GIS62< 5.6 LWOH X X X X X --X X - (OU)S1YLE) GLl125 a, LHIOH X X X X X --X X - 1SPRINJ<LERS StW.L BE LMTEDAS PER TI£R£QUIR£1,E.NTSOIF NFPA13ANlNl'fOTHER RB.ATED CXXUliENTS. • fl-KJRlZONTALSIOEWAU.cUlua LISTED FOR DEFLECTOR.-TO 1r BEI.CNVTHECEUNG, FM'4PPROVED.-TO tr 8ELOWTIE CEtuNG. •INSTALL IN ACCORMHCE TO BS5306 AHO N('( OTHER RE.LATED 00CUMEHTS. 'PENDENT VERTICAL SIDEWAU. dJl.ul USTEO FOR I' MN. SPACH:l. ttJPRIGHT VERllCAL SIOEWAL1 dA.ul LISTED FOR r MIN. &PACNG. ott OROlNAAV HAl.AA.0 ut LIGHT HAZARD -,/l'NPT ORDERING INFORMATION SPECIFY •Quanli!y • Model Number • S,yle •Orifice • Thread Sizes -Temperatu,e • Finishes desired •Quantity· Wrenches· P/N 325390 (1/2"); P/N 312366 (LO.) GL.BE GLOB? PRODUCT WARRANTY G&obe agrees to repair or replace any of ~ °""" manufactured producls found to be defectiye in material or worltmanship for a period of one year from dale of shipmenl For specific details of our wananty please re~ to Price List Terms and Conditions of Sale (Our Price List). 40n AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 FAX ~9231 1-600-248-0278 www.globesprnkler.com flllE SPRIMK1£R CORPORATION JUNE2012 PRINTED U.S.A. BULLETINGLS615,REV.#9 Fireloci«<' V34, K8.0 Model V3428 Quick Response Extended Co\lerage!Light Hazard (ECLH) Pendent and Recessed Pendent Appnwals/Ustings: ,@. ..... ~V1u-11,1..r_ Pl.bll.:~t.r.n 1r..1t in.i n-~rt1,••.,r. ~ Description: These Model V34 ECLH spnnklers are designed with a KB.O orifice size and provide added coverage at normal light hazard operating pressures. Each sprinkler is cast with a hex-shaped wrench boss to allow easy tightening from many angles, reducing assembly effort This sprinkler is available in various temperature ratings (see chart on page 4) and finishes to meet many design requirements. Co-.,ge Extended spray coverage is up to 400 square feet (372 sq. m) per NFPA 13. Job/Owner [~'."No. i ux:ation r Con- l ' I I l~s; I.. __ .J Technical Specifications: Models: V3428 Style: Extended Coverage/ Light Hazard -Pendent. Recessed Pendent Nominal Orifice Size: %"114 mm K FaclDr: 8.0 lmpJl 1.5 S.1.1 ~ctauliC' 40J8 Nominal Thread Size: 14" NPT/20 mm BSPT Max. Wortire Pl'Hsure: 175 psV1200 kPa f~ ~ Test: 100% 0 500 psl'3450 kPa Mln. 0peratq ~ 7 psV48kPa Temperature ~ See chart 1 For K-FKIDrwhel'\ ~ -~ in a.,~ SJ. units t,,, 10.0. Exaggerated lo, clarity ~ I ~~ I f'arat!raph I Approved ! Date oct.aulk.com ! Sp:i',!-:!ers ! Firelcck9 I V?..,4, K8.0 l ?ublk:ation 40.78 .0.78 8496AevA u.:rc-led0lf2015 O2015VldMlic~Mric,htsrcsened. 1 victaullc.com I Spnnklers I Firel..ocl<"' I V34. KB.O I Publicaloo 40 78 ~~I Specifications, Pendent Deflector. Bronze per U NS C22000 Bulb: Glass with glycerin solution Bulb Nomlnal Diameter: 0 Quick Response: 3.0 mm Load Screw: Bronze per UNS C65100 Pip Cap: Bronze per UNS C65100 Sprirc: Beryllium nickel Seal: Teflon' tape Frame: Die cast brass 65-30 ~t ss,rif!:: Sta~__s stee! per UNS S30200 Appmwals/Listires: APPRO'IAl.5/USllNGS I 0r111ce siz. (Inches) 1 ~si,;---i ~KfK"'!.~P."10'1 NomlnalKFact0tS.L' . , ___ '!!!_ • ' I Deflecto, Type I Ap~rowd T~mpe,ature _ Ratings F•,c• u ¥3428 17m·. ,. _i 11.S Quick- ¥3428 17ii2··--,.-· • I Pendent j ~ Pe,..,t ApprOftd Tempaature Rath~ r~•, •~ iFF~-lSS:ftwC-. L . ISS'f.ii!'c _17N/79"C 1--17N/79"C ~3-C _j __ ~lll:C J l.abnp and aPPh)'fail as of pnntJn&. Noc al ~,. ratinc c:ombinal.ions ar&App,owed o, Uszed. Chedt V'ct11ulic fot !peCK combinltlonl. FOi ,c.rac.m, when piu$Ute s measured WI Bar. tl'W.L'liptr S.I. units trt 10. U&N,h&ZWonly Accessories: Installation Wrench 0 Open End: V34 0 Recessed: V34 Sprinkler Fuiishes: D Plain Brass 0 Chrome Plated 0 Whtie Painted D Custo,,; Painted 0 VC-250' • ldbn • • t'l!:IIIStered tradenwt of DUpOri Co. 1 UL lAted w Fw Appnwmt '°' eomacn resa1ancL Dimensions: ,., ,s..,...L+-~!Q;:;;;;;i;!E~'4.:7 40.71 &496Ae.A UpdMed0l/2015 O2015V'mufceon-c,a,.,.M~racf\led. victwlic.com 2 ~ctaul,C' v1t:a_!!l.te.com I Sprinklers I Firel.ock" I V34, K8.0 I Publication 40.78 Room Size: Sprinkler Pttfonnaace: Flow And Pnu.ure (Minimum) V3428 i Room Sile Flow Rate I End Spri:ltlcr Preulff CPMULPM PSl/ld'a I I A.xft. I I-mrm ' UL UL 16X 16 26 10.6 4.9X49 98 73.1 I t----➔ 1ax1a " 17.0 5.SXS.S 125 117.2 20X20 <G 2SJ) 6.1X6.1 150 172.4 Distribution Patterns: r ... T .... : V3428 -0ukk NOTES; ModelsV3428, KS.0 ECLH Pendent Mld Recessed Pendent Dlslribullon Patterns -TrajectMy Minlunun lnstalaion ~ feellrndon ... 2A A 0.ta ~ a ~le and can va,y due ID diNerences in inmn.tion. ---; ,.. ..... ,. .... B. Thae.....,. ___ ,,__,.,._ ... _,_..,,,,blhae,...kV.,.._,F,.i..,,...--...11,ey.,.__,. ~bi!JCMCein..c,idqobstn.c:ti:lns1D~Mdshowdldbeusedasnwwr&m~SS)IICa'Wnjnb~~IDlhe~NFPA Natonal f"tte Codee11N......,,., H9w11Jlftdiction bspech: ~ ~ota~spadnclrr'Cllliaraand ..Ur:ICOlll1'all ~ failu,e btolow ____ ........ _..... ..... _ ...... >oid .. U,,,..._ ... _ C.Alpattr.tn&atw:symm,etncatDthccen~ofthe~. 40.78 8496Rf:'A \Jpdazd0l/2015 O2015Vw;c.utc~.Al,.t,b~ victaulic.com 3 ✓-iCtauliC' victauhc.f_om I Spnnklers I Firelock" I V34, K8.0 I PublicatlOfl 40 78 f!atircs; All glass bulbs are rated for temperatures from -65'F (-54'C) up to those shown in adjacent table. Sp,lnlder ~ ... Claosification <lnlNfy Oodlnaly 1 -~~j _ No ...... ~ _ I ...... Port T..._.t,ft T._ Bulb ldonlifo<allon Ralng -Color i II A 135"f/5'/"C 1 100'f/38"C I o..ng. i. -. I C 1S5"f/611-c 100'f/38"C flod -t 17S'ff79"C 1SO'f/6S'C - ~.i 200'f/93"C 1SO'f/6S'C - Available W!enches: - Vl4 T Vl4 Vl4 &WARNING • AMllp rud Md Wd:nt.nd lnsbiA.tfon, ~. Mid fflantenance-wtrucUons,. 5Upplcd with each boa of sprlh- lden, -~-1ns-...o1 an, sprinlden. • AJw.,.-.. .. .i., p ... ...i foot p,ot,,ction. • o.p.essuri,ie w drain tho p;p-.-bd.,.lllen¢11111D ...t.11,-, °' odjurt.., V'oct...cic plpl1111 pn,ducls. • lnsbllation niles, apecblly U-........,.. obstruction. ... , be 11ri<lly lollowed. • hinUnl, plati1111,,.-, .,...,.. .. of sprinkl,ts (ol"" lhM that ... piled bf Vict>uic) Is not-· falun,1Df-those""1ructionscoolkl ...... ln leriouspenonol injwy...U.. pn,p,riy..._. Tbr .ner is responsible tor l'Nlnbink-c the fn protection system Mm devk:u In proper ope,atirc concltlon. for minimum maintenance: .-.t inspectloft ~rnmu. refer to the cutrent Nat:ioiu Fn Proltction Anocution pam- pl,lel -describes.-...i -.. ,prlnldor -· ,. addition, tho-...., i....,. )url,diclion ..., --rnainlononce, ,....._ and inspection ..qulrement, that OMt be,_ tf JOU nttd additiDnal copies of this publution., o, if ,ou h.e al'ff qua.tiotll about-the uh: insbbtk,n of this. product. co-. Vlctoulc World ~ P.O. ea, 31, e:..ton, Pennsylnnia 18044-0031 USA, Tdephone, OOl-610.559-3300. ~.,_.,...,.._.._,.,. ••IYlctlUllcrfllUldlliulDaMCS,....WS IMUl.lhtarwt......,_~..,hl~YN1-~Thkff...,.._.,.._ lllndwdactwil'tudl~ef\lld&llcpradwdll.r~a.....,__..t.....W, --. ..... ......,,"il"Of"..._.lll'l_wcballit .. ~ -Thll,r00utt1N1er....,.,.lndO,Vk?Ulc••~~Man,ducll ••IMtlllld111~••01nW11Y1c..-.C~~-~_,.tti,,i'11f11IIIQWW'~~~--.,..,.... ~ ..... noke. .......... ~~ -vtc--=-•·--no-wtlofYk-..c~ 40.78 8496RCIA ~ted0!/2015 O2015Vic.~eomc,,.,,,,.M~n:served. ✓-.ctaul1C' v.Ctaulic.com 4 Page 1 of6 'JIKIN@ TECHNICAL DATA EC/QREC ORDINARY HAZARD PENDENT SPRINKLER VK572 (K14.0) The Viking Corpo,,.tlon, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 8TT.;!84-i464 Fu: 269-818-1680 Email: techsvcsgvtklngcorp.com Vi1lt the Viking website for the latest edition of this technie11I data page www.Yiklnggroupinc.com 1. DESCRIPTION Viking Standard/Quick Response Extended Coverage Ordinary Hazard (ECOH) Pendent Sprinkler VK572 Is a thennosensilive glass bulb spray sprinkler with a 14,0 (202 metric") nominal K-Factor. The sprinkler produces Iha flows required lo meet Ordinary Hazard density requirements at lower pressures than B.O or 11.2 (115.2 or 161.4 metric") K-Factor sprinkle~. The glass bulb operating element and special deflector characteristics meet the chaUenges of quick response extended coverage standards. Viking EC/QREC Ordinary Hazard Sprinklers are available in various finishes and temperature ratings to meet design requirements. The spe- cial Polyester coatings can be used in decorative 1pplicatt0ns Vi/here cok>rs are desired. In addition, the ENT coating has been Investigated for installation in cor· rosive environments and is listed as indicated In the Approval Charts. The Viking VKSn Sprinkler may be ordered and/or used as an open sprinkJer (glass bulb and pip-cap assembly removed) on deluge systems. Refer to Ordering Instructions on the next page. 2. LISTINGS AND APPROVALS c®,. cULu.s Listed: Category VNIV <;,? FM Approved: Class 2022 NYC Approved: MEA 89-92-E, Volume 38 NOTI: All ol...,. Z011 _, 1119" ~ be,en ,_lilH ltOM hwt..-dllllo..._ Rerer to Approval Chart 1 and Design Criteria for cULus Listing requirements and refer to Approval Chart 2 and Design Crtteria ror FM Approval requirements that must be fol'°"'9d. 3. TECHNICAL DATA Specifications: Available since 2004, Minimum Operaling Pressure: Refer to the Approval Charts. Maximum Wori<ing Pressure: 175 psi (12 bar). Fadory tested hydrostatically to 500 psi (34.5 bar). Thread size: 3/4' (20 mm) NPT Nominal K•Facior. 14.0 U.S. (202 metric") • Metric: K•factor meas...-ement sho'M'I la in Bar. Vi/hen preu1.Ke ii measured in kPa, divide the rnetnc K•facto, •ho'wn by t0.0. Glass-bulb ftuid temperature rated to ~5 "F (-55 'C) Overall Length: 2-7/16' (62 mm) Material Standards: Sprinkler Frame: Brass UNS-C84400 Detlector. Phosphor Bronze UNS-C51000 Bulb· Glass, nominal 3 mm diameter Pip Cap: Brass UN~1400 or UN~1600 Compression Scn,w: Brass UNS-C36000 Belleville Spring Sealing Assembly: Nickel Alloy, coaled on both sides with PTFE Tape for ENI CQtted ScrinkleCJ· Bel~ville Spring -EJcposed, Screw and Pipcap -ENT plated. for Potvestor Coated ScrinkleCJ· Belleville Spring-Exposed Ordering lnfonnation: (Also refer to the current Viking price list) Order EC/QREC Ordinary Hazard Pendent Sprinkler VK572 by first adding the appropriate suffix lor the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, IM>tte Polyester= M-IW, Blaclc Polyester= M./8, and ENT= JN Temperature Suffix ('F/"C): 155'/68' = B, 175'/79' = 0, 200'/93' = E, and 286'/1◄1' = G, OPEN= Z (PTFE only), For example, sprinkler VK572 with a Brass finish and a 155 •F/66 •c temperature rating= Part No. 13722AB. Available Finishes And Temperature Ratings: Refer to Table 1. Form No. F _072313 19.02 21 Rev 19.1 Replaces Form No. F _072313 Rev 18.3.P65 (Removed F-1 Escutcheon,) TECHNICAL DATA Page 2 of6 EC/QREC ORDINARY HAZARD PENDENT SPRINKLER VK572 (K14.0) The Viking Corporation, 210 N Industrial Park Oriva, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 8TT.;!8-Fax: 269-818-1680 Email: lech1vc1@vtkingcorp.com Visit the VikJng website for the latest edition of this technical data page www.viklnggroupinc.com Accenories: (Also refer lo the Viking webstte.) Sprinkler Wrenches: A. Standard Vl'ranch: Part No 07297W/B (available since 1991) B. Wrench for coeted and/or recessed pendent sprinkler: Pert No. 13032W/B•· (available since 200◄) -A½. ralchel It required (nol avabble from Viking). Sprinkfer Cabinets: A. Six-head capacity: Part No, 01724A (available since 1971) B Twelve-head capacity: Part No 01725A (available s,nce 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Slandards. 5. OPERATION During fire condmons, when the temperature around the sprinkter reaches its operating temperature, the heat•sensitive liquid in the glass bulb expands, causing the bulb to shatter, releasing the pip cap and sealing spring assembty. Water nowing through the sprinkler orifice strikes the sprinkler deftector, forming a ooiform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection. Teshng and Maintenance requirements 7. AVAILABILITY The Viking Model VK572 Sprinkler is available through a net'M)ri( of domestic and international distributors. See The Viking Corpora• lion >Neb site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of wananty, refer to Vtldng's c:ummt bt price schedule or contact Viking directly. Figura 1: P,·otert1ve ~pr nhler ~h Id Standard Sprinkler WNnch 07217YJ/8 {Pendant Sprinlder VK572 shown) ~1· ~~ Sprlnkler \lrench Port No. 13032\1/B•• I : Step 1, Co.refully slide the wrench sldewQys Qround the deflector o.nd protective shleld. <No1:e the orlento. tlon of the of the shield In 1:he wrench.> ••A 1/2' ro. t chet Is required. (Not Q voltoble frOM Viking), J ! ,---" __ ; 1 I I ! [ ______ j Step 21 Carefully press the wrench upwo.rd o.nd turn slightly to ensure engo.ger,ent with the sprinkler wrench flo.ts. Figure 2: Wrench 130S2W/B for Recessed and/or Coated Sprinklers {Pendent Sprinker VK57l shown) Form No. F_072313 19.02.21 Rev 19.1 Page 3 of 6 \IIKINGi TECHNICAL DATA EC/QREC ORDINARY HAZARD PENDENT SPRINKLER VK572 (K14.0) The Viking Corporation, 210 N Industrial Park Drive, Hasting• Ml 49058 Telephone: 269~945-9501 Technical Services: 1n.3u,..s45,4 Fax: 269..S18·1680 Email: techsvcs@vikingcorp.com V1Sit the Viking website for the late.st edition of this technlc:al data page www.vikinggroupinc.com TABLE 1 AVAILABLE SPRlr-.;K.LER TEMPERATURE RATltJGS Ar--..O Fl'JISHES .,......,,._,._ a,,tnlderNomlnal llullnumA-.e Bulb~ ~-Tempe,abnRallnt' Celling T..,__.. Ordinary 155 "F (68 "C) 100 "F (38 "C) Red Intermediate 175 "F (79 "C) 150 "F (65 "C) Yellow Intermediate 200 "F (93 "C) 150 "F (65 "C) Green High 286 "F (141 "C) 225 "F (107 "C) Blue Available Sprinkler Finishes: Brass, Chrome, 'v\'hite Polyester\ Black Potyesterl, and ENT' Corrosion Re1lstant/Prooflng Sprlnkter Finishe: ENT' FootnotH 1 Tha ll,pnnld9f tamc,eraue raung • •iamped on the delledDr 1 Based o,, NFPA--13 otwr limJta ,,...Y 1pt;lty dlperdir,g on fir••~ IPfflkltr kx:ation end o1tltt ~~ of N AulhOrity Htwv .bilckoon Refer to~ nstabjonstaMMdl • The corrcalon-ni••nt coatingil: t.wi p-..d 1he atandlird CDfTO'lion Int r.qui-lld by tha ~ ■g,ancies irdc.lad in h Appvval a-. TheN •• cannot and do not rapreNnt all ~ cor,c,a;..,. e,wironments Pnor ID inatal&all01t ..,.my lhrough OW •l'W>4.!Mt ht N coa~ .,. compatiblll wilh Of auttb6e for h propoNd enVlf'ONMfll For automatic~. he eoatlng9 lndbad ar-. apPII.Mt ID Iha eXpONd •Xlltrioraurtacea oriy. Noa that lhe aprif'(I ia eicpoMd on apnntt.fa ~ PolyHtllr end ENT FOf ENT ooawd aU1DFTaic aprinldera, 0-. waterway la ooalltd 3/◄• NPT 2-7116' <2DnM>I 1-11/t6• (62 r,n) (◄2,9 l'\rl) 1-3/4' Pel"ldent Sprlnkler 13722 CVK572> Celllng Opening Slze1 2-Slt6• (58 7 l'\rl) r1lnll"l1JM 2-1/2• (63.5 l'IM) l"lCUd""-'1'1 lnstotled with o. stondord 1/8' C3.l l"I,..) surFace-riounted escutcheon Figure 3: Pendent Sprink .. , VK572 Dirnerutons wtth a Standard Escutcheon Form No. F _072313 19.02 21 Rev 19.1 Page 4 of6 \IIKINGi TECHNICAL DATA EC/QREC ORDINARY HAZARD PENDENT SPRINKLER VK572 (K14.0) The Viking Corporation, 210 N lnduatrial Park Drive, Huling• Ml 49058 Telephone: 269-945-9501 Technical Services: 8TT-384-5464 Fu: 269-818-1680 Email: techavc.aftvikingcorp.com Visit the Viking website for the latest edition of this technical 41ta page www.vikinggroupinc.com Appn,v11I Chert 1 (UL) I• ,_ ...:.J N ·-----~ :Afx•=--= _, ___ Vlll7ZIK14.II Sprinkler Base SIN NPT Thread Size I Nominal K..factor I Maximum Water I Overall Length Part Number' Inches I rm, I U.S. metric1 I Working Preuure I lnchu I mm 13722 Pendent VKSn l/4 I 20 I 14.D 202 I 175 p<I (12 bot) I 2-7/16 I 62 Minimum w.ter Supply Requirements (cUlus only) c:IA.-'IYC -Maximum I Lil..,.., Sprinkler Spacing Are■ per Ordinary Huard Group I Ordinary Hazard Group N CS-Dolq, LxW' Sprinkler Flow I Pressure I Flow I Pressure Clllorial Pendent Standard Response VK57Z fflt x 16ft.(Umx◄9mt 251111'(236m'J 39 wmC 1a po,(1•10 -co 54 ""'1 J s, gpmC 133 p,1(193 t -o 0112 bar) A1X.81Y 18tx,at.(5.5mx.55ffi 32'4f(J01ml) '"11Pffl012.3po,(t055-Q085ba<J josgpmQ216,,..(24'!1-CU9bar) A1X.81Y 20t x20t (6.1 mwe 1 m) 40011'(372 m'J llllgpmO 18.4,u(227 t -C 127botJ i oogpmQ32.7p,,(J02.8-02.25 bar) A.1X.81Y Qukk Reaponae" 12 t.. ,2 t. (3.7 ffll( 3 7 m) 1441f(134m1) 39gpmQ7.8,,..(1470-Q054bot) J """""'078,,..(147.8-CDS4ba<) ,MX,81Y 1◄t.x14t(4.3mx4.3~ 111611'(182m') 30 ...,,c 1 .,,..,1◄1. -o o54bs) I 39 .... c 1. p~,,•1•-o o.54 .. ~ A1X.81Y Appro'#ed Tempenature Ratings Approved Finis.hes Approved Escutcheons A • 155 "F (68 "C). 175 "F (79 "C), 200 "F 1 -Brau, Chrome, Wllte Pofyester, Black X -standard &Urface--mounted escutcheorm (93 "C), and 286 "F (141 "C)' Potynter, and ENT1' Y • Standard surlace-mounted escutcheor. or recessed 8 -155 "F (68 "C), 175 "F (79 "C), and with the Micromatic4' Model E-1 or E-2 Receand 200 "F (93 "C) Escutcheon Footnot■s ' Part nun"ber shown is the base part numbef. For compSele part number, rehtt to current Viking price bt schedule 2 Mdric K.facu meaau,ement ~ii~ P,8"U'e • rneuu-ed i'\ 81f. ~ p,euu-e • me■Mnd i'\ kPa, clYide tie metric K-tac:mr shov.ri by 10.D 1 This chart shows listings and approva:15 availabte al time of prinling. Other approvals. may be in process. Check 'M1h the manufacturer for eny ed-- citionai approval&. 'cUL.us U&ted for UH in the U.S. and Canada. 'To determine 9Minhnum \1\18ter Suppty Requffemenr tor areas of coverage where length and width of actual sprlnlder spacing are not equal, ■elect the 9Maximum Spmkle, Spadng· from the chart lhat ii equal to or greater than the larger of the aciual spacing ~ength or 'tlllidth) <imensiona used. Exampte: ~ usilg 10 ft& in x 13 t (3.2 m w 4 m) aprintJe, spltCSlg, prO'Ytde 1he ·Mnm1m Watef Suppty Req.,iremenf' llt,ted in the thwt fof 14 ft x 14 ft (4..3 m ,r 4.3 m) spadng. For areas of coverage sm■le, 1han sho'Mi, LMe lhe "Minimum Water SUppty Req.1irement• 1n the appropriate h■z.ard group tor lhe next larger area listed. The tlstance from sprinklers to Mh shal not exceed one-half the "Maximum Sprinkler Spac1ng• 11stec1 lor lhe ·Minimum 'Nater SUpply Req..1ifemeni-used. • FD< Sf,mlde< VKSn "4lh H91 r.,,_.u, 2116 "F ro&lg, lA. reslrida the OR 111&,g ID 11w ..-. i, Ordilary Hezald occupencles ID lhe ~ IA!l1"4)emJro zones 'MH1 a buikfng only, VKSn (JJick rMf)Or'IU SJ)fflklel'5 'M1tl this ten,,eraU"e rating cannot be used houghout lhe property. 'Accepted for use, City of New York Department of Buikings, MEA Number 89-92-E. Vol. 38 J Priof to 2007, ~rinlder VKSn wu d■uified • Stand¥d Responae for al room stz:ea. • clA..us Lilted as to1Tosk>n resistant Form No. F_072313 19.02.21 Rev 19.1 'JIKltG TECHNICAL DATA Page 5 ol 6 EC/QREC ORDINARY HAZARD PENDENT SPRINKLER VK572 (K14.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 177-384-5.(M Fu: 269-318-1680 Email: tachsvcs@vlklngcorp.com Visit the Viking website for the latest edition of this technical data page www.viklnggroupinc.c:om PESIGH CBIJEBLl • IA, (--"'"""""'olctlOll1) sULMI L,il,tjnq RteUJCIDllOtl" ECOH Pendent Sprinlder VKSn is cUlus Listed aa Standard and Quk:k Retponse fof instaflation In accordance ..,_;u, the latest edition of NFPA 13 for extended coverage pendent ,pray apmk2ers as ln<lclted below: • The minimum water supplies and ma>rimum aren of cov~e ahown In Approval CMrt 1 are deligned ID provide the k>Uowing design densibes. 0.15 gpmlft' (6.1 IM>'min) for Oninary-Hazard Gr°"" I densitiea: 02gpm/11.'(81 nvnlmin) lot Ordlna,y-Hallfd Group II denoiffl. • The sprinkler lnttalation rule. contained in NFPA 13 fo, Htended coverage pendeot t,pr.y aprinldera must be folowed with the exception that cULut L&tina (09Yl'.D the IPtclno betftl!CD Viking ECOH Pondeot SodaldeCI tg be I rnillmum of I ft. (2 75 ml to PICYC0l cold 1ofdcriog • Vikiig ECOH Pendent Sprinklers a1e cULus U6ted for use In unob5tructed construction, and nor\COmbustibfe obstructed eonttruetlon conslr.ting or solkt 1teel and/or concrete beams as defined In the latest edition or NFPA 13. • Ceiling slope not to exceed 2/12 (9.S•). Aflo Yiltina ECOH Pendent §Prinkfer YKS72 is IR!Eificafly cULu, Listed rec • For non-combultible obstructed consrrucdon ...thin D1.1sau Of bar joists having non-combustible web members greater than 1• (25.4 mm) 'Mlen apptylng the 4 times obstruction criteria rule as defined in NFPA 13 under -rn,.t,uc:tions to Sprinkler Oischatge Pattam Devefopmenr • For lnstalation under concrete tees when installed as follows: 1. The 1tern1 of the concrete tee construction must be spaced between 3 ft (0 9 m) and 7 ft-6 In (2.3 m) on center. The depth of the conc,ete teH must not exceed 30 m (762 mm). The maximum permittf:d concrete lee length la 32 ft (9.1 m). However, 'Mlere the conaele tee lenglh exceetl& 32 ft (9.1 m), non--c;ombustible b•flle•, aquid In height to the depth of the tees, can be inlltalled ao that lhe space between the tees does not exceed 32 fl (9.1 m). 2 The sprinkle, delec:IDr is to be located i, a horizontal plane at or above I· (25 4 mm) below t,e bottom of lhe concrete tee sterr-.. IMPORTANT: Always refer to Bulletin Form No. F _091699 -Care and Handling of Sprinklers. Also refer to Form No. 08061,. for general care, Installation, and maint·enance information. Viking sprinklers are to be Installed In accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAO, VdS or other simllar organiza. tions, and also whh the provision• of governmental codes, ordinances, and standards, whenever applicable. Form No. F _072313 19.02.21 Rev 19.1 'JIKltG TECHNICAL DATA Page 6 ol 6 EC/QREC ORDINARY HAZARD PENDENT SPRINKLER VK572 (K14.0) The Viking Corporation, 210 N Industrial Park Driv., Hastings Ml 49058 Telephone: 269-9-45-9501 Technical Service.s: 8TT..38~ Fax.: 269418-1680 Email: techavc1@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Approval Chart 2 (FIi) 1,~-,-UYI _k..._. ____ ..._Vllffl(KM.11 :Ar.;=-..,____,: Forlll:-1, HC.Z, OIIII HC4 ~ Sprinkler Base I I NPT Thread Size Nominal K~actor I Maximum Water I Overall L■ngth Part Number' SIN I Working Pru1ure I I I lnchu I mm U.S. I metric" Inches mm 13722 I VK5n I 314 I 20 14.0 I 202 I 175 psl (12 bar) I 2-7116 I 62 Maximum Sprinkler Spacing Maximum A~ FM Approvals' L•W' per Spriokter Pendent Sprinlcler VK572 12 f\. • 12 ft. (3.7 m • 3.7 m) 144 ft'(13,4ml) Reise to P11lao Critfria below A1X 14ft xt41l(4.3mr4,3m) 196 ft' (11.2 m') NOTE: FM instanation guidelines may differ AIX tom cULua andfor NFPA criteria. Refe1 to 1he 16ft x 16 ft.(49 mx 4.9 m) 256 ft' (23.8 m') latest applicable FM Lon Prevention A1X 18 ft. x 18 IL (5.5 m ll 5.5 m} 324 ft' (30 1 m') Data Sheets fnducing 2-0 and 3-26) A1X 201t. x 20 ft. (6.1 m • 6.1 m) 400 ft' (37 2 m') A1X Approved Temperature Ratings I Approved Finish I Approved Escutcheons A· 155 'F (68 'C), 175 'F (79 "C). 200 "F (93 'C), and 286 'F (141 'C)' 1 • Brass X -Standard surface-mounted e,cutcheons Footnotes 1 Pan number ahown It lhe bne part number. For complete pan nunc>e1, refet to current Viking price fiat schedu6e. 1 Metric K-adof meaurernenc lho'M'I is v.tw\ prHM#e is rneasu-ed i, Bal WMN"I preuure is me~ed ii kPa, ct,.,ide he meiic K-fadDr lho'M'I by 10.0. J This chart shows the FM ApprovaJs available at bme of printing. Od'lef approYats mey be In process. Cheek with the manufacturer for any additional approvM. • To determine "Minimum Water Suppty Requl,emenr for areas of CO\lerage ¥1tlere length and 'Mdlh of actual sprinkler spacing are not equal, select the ·Maximum SprfnkM!r Spacing· from the chart that is equaJ to or greater than the larger of the actual spacing (length Of width) dimension, used. Example; When using 10 ft 6 tn x 13 ft (32 m x 4 m) 1prinkler 1paciig, provide the '"Minimum W.ter Supply Requirement"' listed in the chart fo, 14 ft ,i: 14 ft (4.3 m x 4.3 m) spacing. For areas of coverage 1meler than shown, use the •Minimum Water Supply Re('1'fement• in the appropriate hazard group for the next larger a.re• lilted The clltance from sprinklera to walls ahall not exceed one~atf the ·Maximum Sprinlder Spacinsf S.ted for the "Minimum Water Suppty Requnmen-r used. PESfGN CR!JEBIA • EM (HsorellrtoAppn,vllct,.,12-J EM !RIUliXil 8nuie11Jl1Dl1 • Sprinkler VK572 ii FM ApprO\led as a quiet reaponse Non-Storage extended coverage pendent sprinkler as indicated in lhe FM Approval Gulde for use l'I occupancy hazard dasaitcations HC-1, HC-2, and HC-3. For spedlc application and Nlalation requi'ementa. refe,ence the latest applca~e FM Lou Prevention Data Sheeta (including Data Sheet 2-0 ■nd 3--26). FM Global Lou Prevention Data Sheets contafn gukfehnes relating to, but not limhd to: minimum wataf supply requirements, hydrauflc design, ceiling aJope and obstructions, minimum and maximum affowable spacing, and del\ec- tor dlatance bek>w the ceiling. . NOTE: The FM lnstallaUon guidelines may differ from cULus and/or NFPA criteria. IMPORTANT! Always refer to Bulletin Form No. F _091699 • Caro and Handling of Sprinklers. Also refer to Form No. 010614 for general car11, installation, and maintenance information. Viking sprinldera .,. to be installed In accordance with the latest edition of Viking technical data, the appropriate standard• of NFPA, FM Global, LPCB, AP SAO, VdS or other similar organiz.a- dona, and also with the provision• of governmental code■, ordinances, and standards, whenever applicable. Form No. F _072313 19.02.21 Rev 19.1 Replaces Form No. F _072313 Rev 18.3 P65 (Removed F-1 Escutcheon.) As the leading supplier of steel sprinkler pipe, we understand that there are no second chances in fire suppression. You need products of enduring quality and exceptional strength-plus reliable service. You need Bull Moose. ight (lb/ft) 1.461 2.070 ed Wei ht (lb/ft) 1.860 2.754 1.00 1.00 Pieces per Lift 70 51 Lift Weight (lbs) 21' len hs 2,148 2,217 1.1ft Wei ht (lbs) 24' len hs 2,454 2,534 Lift Weight (lbs) 2s· len hs 2,557 2,639 EDDVTHREAD 40 ADVANTAGES: • UL listed (US & Canada) and _FM approved • ASTM A135 and A795 Type E, Grade A Certified • Complit?S with NFPA-13, 13R and 14 • Industry-leading hydraulic characteristics I • CRR of 1.0 and greater • All pipe N DT weld tested Exclusive maker of Reddi-Pipe®·~ RED OR BLA[I( PAINTED PIPE • c®usLISTED <§> APPROVED 2.547 3.468 1.00 44 2,353 2,690 2,802 3.308 4.842 1.00 30 2084 2,382 2,481 OTHER BENEt=tTS/SERVICE : • We have the most stocking locations in the industry, for best delivery and availability • Plain end or roll groove • Eddy Guard II™ Q<lcterial-resistant internal coating • Custom length <>ptions • Hot dipped galvanization Reddi-Pipe® red c,r black pipe eliminates field painting • Compatible for use in wet. dry, preaction and deluge sprinkler systems • The only maker with EPDs (to help earn LEED points). Ci.I NFSA NFPA' I ® TQLC□-I www.tolco.com ., 1>,.11111 ,, NIBCO' , RevIsIon 5/24/2001 Fig. 200 -"Trimline" Adjustable Band Hanger Size Rangu -1/2" thru 8" pipe Material -Carbon Steel, Mil. Galvanized to G90 specifications Function -For fire sprinkler and other general piping purposes. l~nurled swivel nut design permits hanger adjustment after installation. Features - • (1/2" thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. • (2'/," thru 8" Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed . Approvals -Underwriters' Laboratories listed (1/2" thru 8") in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW-H-171 E, Type 10 and Manufacturers Standardization Society SP-69. Type 10. Maximum Temperature -650°F Finish -Mil. Galvanized. For Stainless Steel materi- als, order TOLCO™ Fig . 200WON. Order By -Figure number and pipe size El A '1 {' i·: .. ,-i i .·._: Dimensions • Weights Pipe Rod Size Size Inch Metric A B 1/2 3/8 8mm or 10mm 3'/o 2¼ 3/4 3/8 8mm or 10mm 3'/e 2½ 1 3/8 8mm or 10mm 33/o 2¼ 1 '/• 3/8 8mm or 10mm 3¾ 211. 1 '/, 3/8 8mm or 10mm 37/o 211. 2 3/8 8mm or 10mm 4½ 3 2½ 3/8 10mm 5'/e 4'/e 3 3/8 10mm 5'/, 4 3'/, 3/8 10mm 73/e 5¼ 4 3/8 10mm 7¾ 5 5 1/2 12mm 9'/e 6'1. 6 1/2 12mm 10'/e 6'1, 8 1/2 12mm 13'/o 8¼ B A :.! t;.! I HkJ ~ 'IJ '._:H >'ll'i: Max. Rec. Approx. Load Lbs . Length 400 11 400 11 400 12 400 13 400 14 400 15 600 27 600 29 600 34 1000 35 1250 66 1250 73 1250 136 II Main Olfice/Manulacturing facility• 13h 5,np,nn twr • C:01<>1n <'f\ 9:?~/9 • r1, 909 I}/ '1'>9\l • r,,, 00-1 /J/(\1)1 Customer Ser\lice • o/,,:) l~G 1,:!E;j www.tolco.com ® TOLc□· f www.tolco.com ., 1>,.,1111 01 NIBCO' RevIsIon 5/24/2001 Fig. 98 -Rod Stiffener Size Range -Secures 3/8" thru 7/8" hanger rod Material -Carbon Steel Function --Secures channel to hanger rod for vertical seismic bracing. Finish -Electro Galvanized Note -Available in HOG finish or Stainless Steel materials. Order By --Figure number Thread Rod Cut to Length "~ .. ,;> .. .-,.., ~ ,.: ~. ........ i -.... l,) cures 3/8" thru 7/8" rod in Dimensions • Weights Material -Carbon Steel Maximum Temperature -750°F Finish -Plain Note -Available in Electro-Galvanized and HOG finish or Stainless Steel materials. Order By -Figure number, rod diameter, rod length and finish Rod Size 3/8 1/2 5/8 3/4 7/8 Fig. 100 -All Thread Rod Full Lengths Size Range -Secures 3/8" thru 7/8" rod in 1 O' lengths Material -Carbon Steel Maximum Temperature -750°F Finish -Plain Note -Available in Electro-Galvanized and HOG finish or Stainless Steel materials. Order By --Figure number, rod diameter and finish Dimensions • Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F 750°F Wt.1100 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 1¼ 8000 7140 360 1½ 11630 10370 510 ~ ~ .. ..f@r'·?;?· II Main omce/Manufac1urin9 Facilily • lJ/:, '.;;i,·11i<n11 N·r • <:01i,i1~. t:A 92~/9 • r11 909 /Ji ;,:,w • r~~ 009 /J/ 0JJI) Customer Service • r.oo l'?G 11106 www.tolco.ccm Max. Rec. Load Lbs. For Service Temps 6S0°F 1so°F 610 540 1130 1010 1810 1610 2710 3770 • J 2420 3360 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www.Afcon.org 100 REVERSIBLE BEAM CLAMP 3/4" MOUTH SIZE -318" and 1/2" rod. MATERIAL-Ductile irolL FINISH -Plain, E.G. and H.D.G. LISTINGS -/It\ clo/u& 203-EX 2551 <S> Approval gukk, -Pipe llu&<n FUNCTIO -Hanger assembly attachment to steel flange with thii:kD ... of less than 3/4". !?"!S"'....ALLATIO~ • ?e:-NFPA ! 3 n-ith set sc.c-w up oc ~.,:,u. Torque-318"= 60 inch lbs. or 1/2"= 125 inch lbs. In the absence ofa IOl'qUe wrench, engage set bolt finger tight then additiooally tighlen 1/3 OJm. FEATURES • Listings allow installation with set screw up or down -see drawings. • Maintains CONSTANT HANGER CENTER-LINE, with set sa-cw up or down. • Flat throat back to ~t twisting on flange during installatiOIL ORDERING -Part#, rod size and finish. 1/08 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 WWW. Afcon.otg 162 UNIVERSAL RESTRAINING STRAP SIZE-One size fits both 318" and 1/2" rod or set screw. Available lengths 4 • and longer. MATERIAL-Camon Steel. FINISH -Mil Galvanittd. USTINGS-c@... 203-EX2551 PATENT -No.. 5,897,888 FUNCTION -To eohance banger att:acbment in an:as subject to Eanbquakes. !!-!ST.•.LUTION • •-s::11 tig!lt to s:ruawe and component parts Minimum retUm oo stnp; I" L-<limcnsion is measured from banger rod center to the str1lp end. FEATURES • Fast installatioo for new coasttuclion or retrofit. • Requires no banger disaasembly lo install. IMPORTANT NOTE: "No Not Is Required" Wbcli insmllcd tight to strucrurc and component parts. (Sec drawings provided) ORDERING· Pan# and L-dimeosioo. 1/08 Nut optiooal, if insulfaciem rod dimension or ----------..... ®us LISTED 8007957 GST 10 X CPVC 1-1/2 300 1.5 .,._ 8020957 SWG 10 X CPVC 1-1/2 300 1.5 8008957 GST 20 X 2-1/2 850 1.5 X 4 1475 1.5 8068925 GST 20 SS X 2-1/2 850 1.5 8010957 GST 30 X 4 1500 1.5 X 4 1475 1.5 -8009925 GST 25-380 X 4 1500 1.5 X 4 1475 1.5 -8022925 SWG 25-380 X 3-1/2 -4~ 1500 1.5 X 4 1475 1.5 -8021957 SWG20 X 2-1/2 -3** 1250 1.5 8073925 SWG 20 SS X 2-1/2 1250 1.5 8139957 SH GST 20 X 3 1050 1.5 X 4 1475 1.5 8141957 SH GST 30 X 4 1500 1.5 X 4 1475 1.5 8140957 SH GST 20 SS X 3 1050 1.5 8142957 SH GST 30 SS X 4 1500 1.5 8038957 DSTR 1 X 4 1500 0.035 X 4 1475 0.1050 8037957 DSTR 1-1/2 X 4 1500 0.035 X 4 1475 0.1050 8039957 DSTR 516 X 4 1500 0.037 X 4 1475 0.1050 8045957 DST 516 X 4 1500 0.188 X 4 1475 0.1875 8046957 TEK 50 X 4 1500 0.250 X 4 1475 0.1875 8055957 SWDR1 X 4 1500 0.037 X 4 1475 0.0600 8056957 SWOR 516 X 4 1500 0.037 X 4 1475 0.0600 8054957 SWOR 1-1/2 X 4 1500 0.037 X 4 1475 0.0600 8137957 SH DSTR 1 X 4 1500 0.035 X 4 1475 0.1050 8150922 XP 20 X 2 750 0.027 X 4 1475 0.1050 8153922 XP 35 X 3-1/2 1250 0.043 X 4 1475 0.1050 . '~~; , ! I I ' I , ~ .f" , ,1 1 l t I II \j, ,, ' .:, \; l l,11 ' ' . •,1, 1111.\\"!1'1.il ,➔• I I ~ I; I , l < ,. ' •. 8059957 CST 20 8061957 swc 20 X X * SWG 25-380 Maximum pipe size in composite wood joist allowed by UL is 3-1/2" SWG 25-380 Maximum pipe size in wood timber or joist allowed by UL is 4" ** SWG 20 Maximum pipe size in composite wood joist allowed by UL is 2-1/2" ** SWG 20 Maximum pipe size in wood timber or joist allowed by UL is 3" UL and FM tests were performed in compliance with NFPA-'\3 Standards. 4 4 1475 1475 3000 PSI 3000 PSI /Tl~rBuildex Fastening requirement: 5 times weight of water filled schedule 40 pipe plus 250 pounds. www.itwbuildex.com 800-284-5339 SSS26 TECHNICAL DATA 1 of3 HOLE CUT SYSTEM MODEL V-n:J SADDLE LET MECHANICAL TEE The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 8TT--Jll4-6464 Fax: 269~18-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION VGS-Model v-n3 Saddle Let small mechanical tees are available in sizes 1.114• !IYough 2-112•. The Models V-n3 mechanical tees provide an easy take-<>ut of a brandl outle1 without the need for >Nelding. \/G,S't Mechanical Tees are rnanufao.. tured at 1509001 cer1ified facilities an are designed to conform to ASTM and other standards where applicable. Threads are NPT per ANSI B1.20.1. 2. USTiiliGS AND APPROVALS ,@., Guide No. VIZM <8> Class 1920 3. TECHNICAL DATA SpecificattOns: Maximum wort<ing pressure: 300 psi (21 bar) can bit acessul Ill http:llwww.vUcinggrouptnc.com. Scan to vis;t ot.ir Mobile webaib!:: g::e ~~,:orming to ASTM A536 hUp:/IYiklnnoup.mobl/p/46374 Standatd black finish Hot dipped Zinc galvanized versions are available (conforming toASTMA153); when ordering, add a -o• suffix to the Model number. Rubber compound EPDM Grade E conforming to ASTM 02000. AWNA C606, NSF 61 and IAPMO. Nuts and Bohs; Zinc plated, Carbon Steel conforming to ASTMA183 Grade 2 (UNC nuts and botts are a silver chromate color and ISO are a gold chromate color) Tobie t V-723 ModelV-723 MeehanicaJ Tee JJ}f ~-7-----;-~-;~iif~t-;t,'tJi~';S,~ ,::'{ 1.25,c 0.5 1.18 1.87 3.5 2.2 1.63 U.Sol 20-22 0.9 (32 X 15) (301 1481 (8ll) (56) 1421 131811 127-30) I0.41) 1.25 X 0.75 1.18 1.87 3.5 2.2 1.63 U-Sol 20·22 1.0 (32x20) (30) (48) c••l 156) (42) (3181) (27-30) (0.45) 1.2Sx 1 1.HI 2.04 3.5 2.2 1.73 L>-Bol 20-22 1.0 (32 x251 (30) (52\ C8•l (56) (44) 13181\ (27-30) 10.45\ 1.Sx0.5 1.18 2.04 3.5 2.2 1.78 U.Sol 20·22 0.9 (40x 15) (30\ (52) 18•1 (56\ (46) 13/B■l (27-30\ (0.41) 1.Sx0.75 1.18 2.04 3.5 2.2 1.79 U-Sol 20-22 0.9 (40x20) (30) 152) (89) (561 (48) 13181) 127-301 10.411 1.Sx 1 1.18 2.04 3.5 2.2 1.69 U-Sol 20-22 0.9 140x251 1301 r52) 189) (56) 1431 131811 (27-30\ 10.411 2x0.5 1.18 2.30 3.86 2.2 2.07 U-Solt 20·22 I~:,, 1sox 15) (30) (591 (981 156\ (53\ 1319,1 '27-30\ 2x 0.75 1.18 2.30 3.86 r2s;I 2.tn U-601 20-22 o.• (50 X 20) (30) (59) (98) (531 (3181) 127. 30\ 10.411 2x1 1.18 2.30 3.86 2.2 1.87 U-6ol 20-22 1,0 150 x25) (301 (59\ (98) (56) (50) (3181) (27-30) (0.45) 2.S x0.5 1.18 2.46 4.37 2.2 2.22 U-Sol 20-22 1.0 155x 15\ (301 163\ (111) 156) 1571 131811 '27-301 10.451 2.Sx0.75 1.18 2.46 4.37 2.2 2.22 =~ 20-22 1.0 165 X 201 (30l 163\ (1111 156) 157\ (27-30) 10.45\ 2.Sx 1 1.18 2.46 4.37 2.2 2.13 U-8oll 20-22 1.0 (65 X 251 (30) 163) 11111 1561 154\ l'.\Al1\ 127 -30) 10.45\ ..-to._ diameters .. suggest.ad hole a.aw diamemr.. -r. Tek~l-1! !C~.=r =! !".Jr. ~ =r::! :1 ~!;.: != !:c e.·.;ai;&d1 Form No. F_110515 16.12.08 Rev 16.1 Replaces Form No. F_110515 Rev 15.1 (Added K-factor limit table and flow data) TECHNICAL DATA 2 013 HOLE CUT SYSTEM MODEL V-723 SADDLE LET MECHANICAL TEE The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 8TT-384-5464 Fax: 269~18-1680 Email: techsvcs@vikingcorp.com 4. HOLE CUTTING The ho~ method of pipe preparation is required when using medianK:al tees, med\anical crosses, and saddle--4ets. The method of pipe preparation requires the a.rtting or drilling of a specified hole size on the centerline of the pipe. A'fwir.Js use the correct hole saw size as shown this data sheet and never use a torch for cutting a hole. After the hole has been cut aft rough edges must be removed and the area within 518" (16 mm) of the hole should be inspected to ensure a clean smoolh surface, free of atTY indenta- tions or projedions that could affect proper gasket sealing. The area within the "A" dimension should also be inspected and must be free for dirt. scale or any imperfection that coutd ciffect proper se2ti~ or as.2..~ of the fit!!~. :,0 ... --... \: --+~ --H--- ' \. / I I '~ .," I I I 5. INSTALLATION NOTES: Use a wrench to hok:i the threaded outlet in place when instamng the sprinkler. T,ghten the nuts evenly, Fom, No. F _110515 16.12.08 Rev 16.1 Do not install sprinkler directly into Saddle-Let wi!h 1· outlet Hole Gaskel Threaded outlet ~ Nuts :l Sprinl<ler J~ Figure 1: V-723 Saddle-let lnatallation TECHNICAL DATA 3of3 HOLE CUT SYSTEM MODEL V-723 SADDLE LET MECHANICAL TEE The Viking Corporation, 210 N Industrial Parle Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877~ Fax: 269-ll18-1680 Email: techsvcs@Yikingc;orp.com 6. FLOWOATA Equ1 .al1?nt Length of Outlet Size Schedule 40 ca,.bon Steel Pipe Per UL 2i3 Section 16 C=120 E::~~---~ ~ ---~~~~~F6i:: __ ·. ___ ,_· jT::~~~j~r ... ~ 1"~/ • _._:_-_ ~ -_:_:: __ ~i 11-723 V-723 V-723 V-723 Flow test data has shown that lhe total head loss bet.w!en point A and B for the fittings can be expressed in terms of the pressure difference across the inlet and branch. The pressure difference can be obtained from the relationship below. 125 1.5 2 2.5 Form No. F _ 110515 16.12.08 Rev 16.1 8 1 1 1 1 5 27 6 27 5 27 3 38 Formulu lo, CV \lalues: W'tere: Q • Flow (GPM) AP • Pressure Drop (psa) C.., • Flow Coefficient Replaces Form No. F _110515 Rev 15.1 (Added K·fador limi1 table and flow data) •