HomeMy WebLinkAboutSDP 2018-0020; 540 CHESTNUT SFR; RESPONSE TO CITY OF CARLSBAD THIRD PARTY GEOTECHNICAL REVIEW (FIRST); 2020-05-15jo~ CT
N%e~~
E INC
May 15, 2020
Construction Testing & Engineering, Inc.
Inspection I Testing I Geotechnical I Environmental & Construction Engineering I Civil Engineering I Surveying
CTE Job No. 10-13921S
BG Consolidated
Attention: Mr. Tom Gaeto
1441 Montiel Road, Ste 115
Escondido, California 92026
Telephone: (760)746-4955
lECEwjED
JUN25 202C
cc: David Caron-Civil Landworks: dave@civrllandworks.com LAND DEVELOPMENT
ENGINEERING
Subject: Response to City of Carlsbad Third-Party Geotechnical Review (First)
Comments from Hetherington Engineering, Inc. Project Number: 9096.1
Dated April 2, 2020, Project ID: GR2020-0009
540 Chestnut Avenue
Carlsbad, California
References: At the end of document.
Mr. Gaeto:
As requested, Construction Testing & Engineering, Inc. (CTE) provides the following responses to the City
of Carlsbad review comments. Responses below are in response to Third-Party Geotechnical Review (First)
dated April 2, 2020. Applicable responses are provided below and are numbered based on the comment
numbers enumerated in the third-party city review.
GEOLOGY RESPONSES:
No. 1: The Consultant should review the project grading and foundation plans, provide any additional
geotechnical recommendations considered necessary, and confirm that the plans have been prepared in
accordance with the geotechnical recommendations.
Response to No. 1: CTE has reviewed the referenced grading plans and finds them to be in substantial
conformance with CTE's geotechnical recommendations provided in the referenced report. No exceptions
were noted. CTE has not yet been provided structural plans for review, but anticipates performing a
geotechnical review of them once available.
No. 2: The Consultant should provide an updated geotechnical map/plot utilizing the latest grading plan for
the project to clearly show (at a minimum) a) existing site topography, b) proposed structure/improvements,
c) proposed finished grades, d) locations of the subsurface exploration, e) geologic contacts, and f) remedial
grading limits, etc.
1441 Montiel Road, Suite 115 I Escondido, CA 92026 I Ph(760)746-4955 I Fax (760)746-9806 I www.cte-inc.net
3
Response to Third-Party Geotechnical Review (First) Page 2
Proposed Residential Development
540 Chestnut Avenue, Carlsbad, California
May 15, 2020 CTE Job No. 10-13921S
Response to No. 2: An updated geotechnical map/plot utilizing the latest grading plan for the project that
shows existing site topography, proposed structure/improvements, proposed finished grades, locations of the
subsurface explorations, geologic units, and remedial grading limits is provided as Figure 2.
No. 3: The Consultant should provide a detailed description of proposed site grading,
structures/improvements, etc.
Response to No. 3: The site as currently proposed is to consist of three residential structures founded on
conventional shallow foundations properly embedded into compacted fill materials. Typical additional
improvements such as exterior pavements and flatwork, utilities, and landscaping are also proposed. As
recommended in CTE's referenced report, site grading is anticipated to consist of a two foot or deeper
overexcavation prior to placement of engineered fill in compacted lifts.
No. 4: The Consultant should address whether the site is considered a "Near Fault Site" in accordance with
2019 CBC, Section 1803.5.12.
Response to No. 4: Based on distance to the Rose Canyon Newport Inglewood Fault Zone, which is
approximately four kilometers to the west, the site may be considered a near-fault site as defined by ASCE
7-16, Section 11.4.1.
No. 5: The Consultant should provide the site Risk Category and Seismic Design Category consistent with
the 2019 CBC.
Response to No. 5: In accordance with the 2019 CBC Table 1604.5, Risk Category II is applicable for the
site and improvements. Based on the Risk Category and design spectral response acceleration parameters,
SDS and SD!, Seismic Design Category D is assigned for the site structures in accordance with ASCE 7-16,
Section 11.6.
No. 6: The Consultant should provide a statement regarding the impact of the proposed grading and
construction on adjacent properties and improvements.
Response to No. 6: Based on CTE's review, the proposed grading shown on the referenced grading plans is
not anticipated to detrimentally impact adjacent properties or improvements, provided CTE's previous and
future (provided as necessary and as requested) geotechnical recommendations are implemented.
No. 7: The recommended coefficient of friction exceeds 2019 CBC presumptive values. The Consultant
should justify or update as necessary.
Response to No. 7: As per table 1, page 7.2-63 of the referenced design manual (NAVFAC, 1986), the
range of friction factors for mass concrete on silty fine- to medium-sand is 0.35 to 0.45. CTE considers our
recommended value of 0.30 to be conservative.
S:\Projects\10-13000 to 10-13999 Projects\ 10-1 3921 S\Comments\Ltr_Response to Review Comments.doc
Response to Third-Party Geotechnical Review (First) Page 3
Proposed Residential Development
540 Chestnut Avenue, Carlsbad, California
May 15, 2020 CTE Job No. 10-13921S
No. 8: The Consultant should provide a minimum slab thickness for exterior hardscape.
Response to No. 8: Exterior hardscape should measure a minimum of 4.5 inches in thickness.
No. 9: The Consultant should provide a list of recommended observation and testing during the site grading
and construction.
Response to No. 9: As is typical and at a minimum, a CTE geotechnical representative should observe and
approve the dimensions and bottoms of excavations for overexcavation, footings, utilities, and other
subsurface features. Additionally, CTE should be scheduled by others to test field relative compaction and
moisture content of placed engineered fill soils, and should be allowed to collect additional geotechnical
samples, as necessary and appropriate.
CTE should observe and verify site conditions during construction. This report is subject to the same
limitations as our previous project geotechnical documents.
We appreciate the opportunity to be of service on this project. Should you have any questions or need
further information please do not hesitate to contact this office.
Respectfully submitted,
CONSTRUCTION TESTING & ENGINEERING, INC.
.
7 71 4-e-
Jay F. Lynch, CEG #1890
Principal Engineering Geologist
No.1890 °I C91F1ED Coim J. Kenny, RCE 484406
Senior Engineer
No.
:/30f/21
40 ..(
EXP.
CIVIL
OF C CJKIJFL:ack
ATTACHMENTS:
Figure 2 Updated Geotechnical Map
5:\Projects\10- 13000 to 10-13999 Projects\ 10-13921 S\Comments\Ltr_Response to Review Comments. doc
Response to Third-Party Geotechnical Review (First) Page 4
Proposed Residential Development
540 Chestnut Avenue, Carlsbad, California
May 15, 2020 CTE Job No. 0-13921S
REFERENCES:
Geotechnical Investigation
Proposed Residential Development
540 Chestnut Avenue, Carlsbad, California
CTE Job No. 10-13921S, dated February 25, 2020
Review of Grading Plans and Drainage Design
540 Chestnut SFR
540 Chestnut Avenue, Carlsbad, California
CTE Job No. 10-13921 S, dated January 17, 2019
Preliminary Grading Plans For: 540 Chestnut Avenue SFR
Prepared by Civil Landworks, dated December 18, 2018, updated February27, 2020
City of Carlsbad
1st REVIEW FOR V 2018-0010/SDP 2018-0020 (DEV2017-Q138)-540 CHESTNUT SFR
540 Chestnut Avenue, Carlsbad, California
Dated October 25, 2018
Foundations & Earth Structures
Design Manual 7.02
Naval Facilities Engineering Command (NAVFAC), dated September 1, 1986
S:\Projects\1 0-13000 to 10-13999 Projects\10- 1392 1S\CommentskLtr_Response to Review Comments.doc
0+0330 4+0775 I I •577OA4E44;4W•r
1
- —Approximate Limit of Remedial Grading
a 701+00000303 +05503T •
ir.;~
I I
r '' '' LOT SI Pt 4+50447 WALL TO 1 I I
If
LLJ
804+30+9 I 70 , +04+4+0110 PT 0+11034+ Il 0+
3
FF=52.60 B-2
52. MYUCE 4.13 M.5
LOX
15.
49 4 WE 110.
4.16
cli 22t- — H
aP0110WO — a pcc oo+ojo I
CIO R_ a 7f 3104+4 4400 PET 04090 340-5 —+
N - - - — — - 0) - 4 • 4+30 00 IT 4490 PER 04080 3443-5 5+00 5+30 Id.w _+_ ---+----- -
- CHESTNUT AVENUE
U. FWXIERPERONW+O 74+-S A
4 44
J+
0 --=------ ,,-=--=---- ------ iT _-
0) -I 0) 0)
0
LEGEND
B-2 APPROXIMATE BORING LOCATION 15 30'
Qop QUATERNARY OLD PARALIC DEPOSITS
IL JUD Flu:
Construction Testing & Engineering, Inc. IGE0L0GIC/EXPLORATION LOCATION MAP 1013921S
PROPOSED RESIDENTIAL DEVELOPMENT
1441 Montiel Rd Ste 115, Escondido, CA 92026 Ph 60) 74955 540 MESTNUT AUE 1__=30'
r CARlSBAD, CALIFORNIA 5/20 2