HomeMy WebLinkAboutDEV 2016-0043; VAUGHN RESIDENCE; DRAINAGE SUMMARY; 2017-09-06COFFEY ENGINEERING, INC.
September 6, 2017
Engineering Department
City of Carlsbad
1635 Faraday Ave
Carlsbad, CA 92008
Re: Drainage Summary
Vaughn Residence
2605 Crest Drive, Carlsbad, CA 92008
Dear Sir or Madam:
#•4 W
k\ 1. 4.)
SEP O. Oi7
LAND DEVELCPjE:T
EN G;
The existing site consists of a vacant 0.28 AC lot located at 2605 Crest Drive in Carlsbad, CA.
Drainage on the vacant lot can best be described as sheet flow with runoff flowing from the eastern
corner of the site in a westerly direction. The grade falls in elevation approximately 9 ft. over a
distance of approximately 200 ft.
The drainage area tributary to the site consists of the site itself (12,344 ft2), a portion of the fronting
road (apprx. 3,000 ft2), and a portion of the neighboring lot to the southeast (apprx. 9,200 ft2). Attached
to this letter is an exhibit depicting the extent of the drainage area tributary to the site.
Runoff from the area tributary to the subject property exits the site at the western property corner
where is continues westerly for approximately 90 ft. where the terrain begins to fall in a southwesterly
direction and runoff continues to the next street over (Wilson Street).
Current discharge from the tributary area containing the project has been calculated to be 1.34 cfs for a
100-year storm.
The proposed construction consists of a new single family residence with a footprint of approximately
21600 ft2, car port, driveway as well as landscaping and minor hardscape. Drainage for the proposed
site will be accomplished by surface sheet flow only. No subsurface drainage system is proposed. The
proposed development will require minor grading (30 CY - balanced) to create a pad for the proposed
home and to fine grade the driveway. No significant changes in overall topography are necessary or
proposed from the existing conditions.
Rainwater from the house will be collected at the downspouts and routed to a cistern to be used for
irrigation purposes. Runoff from the driveway and offsite tributary area will be intercepted by a
vegetated swale along the southern edge of the subject property where it will flow westerly then
northerly, ultimately discharging to an existing riprap pad at the westernmost corner of the site. Runoff
from the remainder of the site (landscaping areas and perimeter of the house) will flow along the
-
9666 BUSINESSPARK AVENUE, SUITE 210, SAN DIEGO, CA 92131 PHONE: (858) 831-01 11 FAx: (858) 831-0179
surface to a vegetated swale along the northern edge of the subject property where it will then flow
westerly, ultimately discharging to the existing riprap at the westernmost corner of the site.
Calculated discharge from the developed condition of the tributary area containing the project has been
calculated to be 1.48 cfs for a 100-year storm. The calculated maximum discharge velocity of the
proposed vegetated swales to the exiting riprap at the rear of the site is 1.90 fps. The existing riprap
(No. 2 Backing per Dwg. No. 485-4A) is an appropriate size for this velocity.
If we can be of further assistance in providing any additional information, please feel free to contact
us. Thank you.
Sincere / 44,7
Daniel Vald , PE
Coffey Engineering, Inc rn
ly- No. C0760'74
Page 2 of 2
DNI 'ONIèIJNION AdJOD C:E
\400
_
\ _
42
_
'*lot
RXI 141
URI
.4
rT
Aid
(eJoE 99o) JS
1!C f1 )!
Ik
t$k Oki
AW iø&'*
L 'b
Ag :s(
W7
low
IV
V.,..
4
N1.
ji
11
:AS..•
..
I '
____ F' ___ •
Table A - Weighted Runoff Coefficients ('C')
impervious/ Percent
Developed Area Pe
7(SF)
s Area Impervious/De
DMA (SF) Total (SF) Total (Ac) CValue* veloped
Pre 12,200 12,344 24,544 0.56 0.35 49.71%
Post 16,470 8,074 24,544 0.56 0.38 67.10%
*Impervious Areas C=0.45; Pervious Areas C=0.25; Pervious Payers Cr0.40
Table B - Project Runoff Calculations
Natural Watercouce (per Fig 3. Urban Overland (Sheet) Flow (per Fig. 3-3) Pipe/Channel Flow Summary 100-yr P6 = 2.60
minimum)
Natural Urban Total time-
Element & Change in watercouse watercours Maximum Initial Ttime of Average Pipe travel of-
Flow ID Dwelling Watercourse Elevation, H duration, D, e distance, Overland Flow Runoff Concentration Overland Flow Pipe Length, velocity, V time, T concentrati Runoff Coefficient, Rainfall Intensity, I Basin Area, A Q(cfs) =
(Basin) Unit/Acre distance, L (ft) Elev. 1 Elev. 2 (ft) (mm) Ti (ft) (!5 LM) Length Watercourse slope, s (%) Coefficient, C (per Fig. 3-2) Time, Tt (mm) L (ft) (fps) (mm) on, r (mm) C (in/hr) (acres) C*l*A
Pre MDR-4.3 228 186 177 9 1.77 0.00 0.00 5.00 0.35 6.85 0.561 1.34
Post MDR-4.3 ____________ ______ 0 0.00 ________ __________ _________________ ___________ ___________ 0.00 228 1.4 2.81 5.00 0.38 6.85 0.561 1.48
San Diego County Hydrology Manual Section: 3
Date: June 2003 Page: 6 of 26
Table 3-1
RUNOFF COEFFICIENTS FOR URBAN AREAS
Land Use Runoff Coefficient "C"
Soil Type
NRCS Elements County Elements % IMPER. A B C D
I Undisturbed Natural Terrain (Natural) Permanent Open Space I 0* 0.20 I 0.25 I 0.30 0.35
Low Density Residential (LDR) Residential, 1.0 DU/A or less 10 0.27 0.32 0.36 0.41
Low Density Residential (LDR) Residential. 2.0 DU/A or less 20 0.34 0.38 0.42 0.46
Low Density Residential (LDR) Residential, 2.9 DU/A or less 25 0.38 0.41 0.45 0.49
Medium Density Residential (MDR) Residential, 4.3 DU/A or less I 30 0.41 I 0.45 I 0.48 0.52
Medium Density Residential (MDR) Residential, 7.3 DU/A or less 40 0.48 0.51 0.54 0.57
Medium Density Residential (MDR) Residential, 10.9 DU/A or less 45 0.52 0.54 0.57 0.60
Medium Density Residential (MDR) Residential, 14.5 DU/A or less 50 0.55 0.58 0.60 0.63
High Density Residential (HDR) Residential, 24.0 DU/A or less 65 0.66 0.67 0.69 0.71
High Density Residential (HDR) Residential, 43.0 DU/A or less 80 0.76 0.77 0.78 0.79
Commercial/Industrial (N. Corn) Neighborhood Commercial 80 0.76 0.77 0.78 0.79
Commercial/Industrial (G. Corn) General Commercial 85 0.80 0.80 0.81 0.82
Commercial/Industrial (O.P. Corn) Office Professional/Commercial 90 0.83 0.84 0.84 0.85
Commercial/Industrial (Limited I.) Limited Industrial 90 0.83 0.84 0.84 0.85
Commercial/Industrial (General I.) General Industrial 95 0.87 0.87 0.87 0.87
*The values associated with 0% impervious may be used for direct calculation of the runoff coefficient as described in Section 3.1.2 (representing the pervious runoff
coefficient, Cp, for the soil type), or for areas that will remain undisturbed in perpetuity. Justification must be given that the area will remain natural forever (e.g., the area
is located in Cleveland National ForcsO.
DU/A = dwelling units per acre
NRCS = National Resources Conservation Service
3-6
EQUATION
L E
Tc= (11 i.913\0.385
1Feet LE
5000 Tc = Time of concentration (hours)
I = Watercourse Distance (mites)
h-400° LE = Change in elevation along
effective slope tine (See Figure 3-5) (feet)
3000 Tc I-- Hours Minutes
I- 2000 4 L 240
3 I 180
—1000
900
800 2 120
'D0 100
600\ 90
_500\\ Ba
—400 \ 70
—NO 1 60
300
50
—200 40
L
Miles Feet 30
100
4000 20
18
300 16
-50 0.5--14
-40 2000 12
1800
1600 10
-30 1400 \ 9
1200 8
.20 1000 7 900
800 6
700
5 600
-10 500 4
400
3 300
200
L
SOURCE: California Jivisioi of Highways (1941)and Kirpich (1940)
FIGURE
Nomograph for Determination of
Time of Concentration (Tc) or Travel Time (It) for Natural Watersheds 3.4
(1nh111hTcfS2n lhia0
33* 0re
_________
Hydrology Manual
_________ _________ _____
/ .. Riverside County
01
%r
Lp
k—' Rainfall Isopluvials
I
_ ______________ .
100 Year Rainfall Event6 Hours
4.0
laopkMal (inches)
P6=26
EN
33OO __ 3O
-L
I I
tbt4±Lft -, H
- I 'SANDIEOO/ /N
\C\l 5 =ON •. /ico '.
245
T -------
DPW ---------
_
_
_
M e x I
3230
to - - 3230
3 0 3MHes
6
Oranqej
County!
L O
3330 I
3315
Cciiinti cfFii, fla0
Hydrology Manual
occr
Rainfall Isoplu-vials
100 Year Rainfall Event -24 Hours
- 8opIaI (Inchos)
3245'
t.
n
I—
DPW -GIS SanGIS H— S— T),o (<,vjd! + ( *PCIEU C*aLIflOI &ITFtTLUSTEU1O WE .LUOWARR.H,la r, C*AWNTMWI1VflCFTflfQEApAflflCL,fiflU.O3E UU
E
3230 S
3 0 3Mlles
C
4
4
33 10 23N
Hydrologic Soil Group—San Diego County Area, California
(Vaughn Residence - Hydrologic Soil Group)
C
4
33° 1023N
I
468550 468550 468570
33° 10 21" N
46&190 468E03 4510 42fl 45.5?O 468540
C
Map Scale: 1:441 if punted on teidscape (lix 8.5) shea
MetersN 0 5 10 20 CD
A Aeet
0 20 40 a) 120
Map projection: Web Mercator Corner coordinates: WGS84 Edge tics: UTM Zone uN WGS84
USDA Ndtulal Resources Web Soil Survey
Conservation Service National Cooperative Soil Survey
33° 10'21"N
C
9/1/2017
Page 1 of 4
13 u
C/D
•
Not rated or not available
Water Features
Streams and Canals
Transportation
Rails
Interstate Highways
US Routes
Major Koads
Local Roads
Background
Aerial Photography
Hydrologic Soil Group—San Diego County Area, California
(Vaughn Residence - Hydrologic Soil Group)
MAP LEGEND MAP INFORMATION
Area of Interest (AOl)
Area of Interest (AOl)
Soils
Soil Rating Polygons
ND
BID
CID
ri
Not rated or not available
Soil Rating Lines
— A
— ND
B
— B/D
-- C
D
0 Not rated or not available
Soil Rating Points
• A
• ND
• B
• B/D
The soil surveys that comprise your AOl were mapped at
1:24,000.
Warning: Soil Map may not be valid at this scale.
Enlargement of maps beyond the scale of mapping can cause
misunderstanding of the detail of mapping and accuracy of soil
line placement. The maps do not show the small areas of
contrasting soils that could have been shown at a more detailed
scale.
Please rely on the bar scale on each map sheet for map
measurements.
Source of Map: Natural Resources Conservation Service
Web Soil Survey URL:
Coordinate System: Web Mercator (:31)
Maps from the Web Soil Survey are based on the Web Mercator
projection, which preserves direction and shape but distorts
distance and area. A projection that preserves area, such as the
Albers equal-area conic projection, should be used if more
accurate calculations of distance or area are required.
This product is generated from the USDA-NRCS certified data as
of the version date(s) listed below.
Soil Survey Area: San Diego County Area, California
Survey Area Data: Version 10, Sep 12, 2016
Soil map units are labeled (as space allows) for map scales
1:50,000 or larger.
Date(s) aerial images were photographed: Nov 3, 2014—Nov
22, 2014
The orthophoto or other base map on which the soil lines were
compiled and digitized probably differs from the background
imagery displayed on these maps. As a result, some minor
shiffing nf map unit hniunclaries may he evident.
USDA Natural Resources Web Soil Survey 9/1/2017
211111111111 Conservation Service National Cooperative Soil Survey Page 2 of 4
Hydrologic Soil Group—San Diego County Area, California Vaughn Residence - Hydrologic Soil
Group
Hydrologic Soil Group
Hydrologic Soil Group— Summary by Map Unit - San Diego County Area, California (CA638)
Map unit symbol Map unit name Rating Acres in AOl Prcent of AOl
CbC Carlsbad gravelly loamy B 0.2 81.1%
sand, 5 to 9 percent
slopes
MIE Marina loamy coarse B 0.1 18.9%
sand, 9 to 30 percent
slopes
Totals for Area of Interest 0.3 100.0%
Description
Hydrologic soil groups are based on estimates of runoff potential. Soils are
assigned to one of four groups according to the rate of water infiltration when the
soils are not protected by vegetation, are thoroughly wet, and receive
precipitation from long-duration storms.
The soils in the United States are assigned to four groups (A, B, C, and D) and
three dual classes (AID, BID, and CID). The groups are defined as follows:
Group A. Soils having a high infiltration rate (low runoff potential) when
thoroughly wet. These consist mainly of deep, well drained to excessively
drained sands or gravelly sands. These soils have a high rate of water
transmission.
Group B. Soils having a moderate infiltration rate when thoroughly wet. These
consist chiefly of moderately deep or deep, moderately well drained or well
drained soils that have moderately fine texture to moderately coarse texture.
These soils have a moderate rate of water transmission.
Group C. Soils having a slow infiltration rate when thoroughly wet. These consist
chiefly of soils having a layer that impedes the downward movement of water or
soils of moderately fine texture or fine texture. These soils have a slow rate of
water transmission.
Group D. Soils having a very slow infiltration rate (high runoff potential) when
thoroughly wet. These consist chiefly of clays that have a high shrink-swell
potential, soils that have a high water table, soils that have a claypan or clay
layer at or near the surface, and soils that are shallow over nearly impervious
material. These soils have a very slow rate of water transmission.
If a soil is assigned to a dual hydrologic group (AID, B/D, or CID), the first letter is
for drained areas and the second is for undrained areas. Only the soils that in
their natural condition are in group D are assigned to dual classes.
USDA Natural Resources Web Soil Survey - 9/1/2017
Conservation Service National Cooperative Soil Survey Page 3 of 4
Hydrologic Soil Group—San Diego County Area, California Vaughn Residence - Hydrologic Soil
Group
Rating Options
Aggregation Method: Dominant Condition
Component Percent Cutoff: None Specified
Tie-break Rule: Higher
USDA Natural Resources Web Soil Survey 9/1/2017
Conservation Service National Cooperative Soil Survey Page 4 of 4