Loading...
HomeMy WebLinkAboutCT 15-08; RESPONSE TO REVIEW COMMENTS; 2020-08-10Geotechnical Engineering Construction Insuection Materials Testing Environmental OFFICE LOCATIONS SAN Diaco IMPERIAL COUNTY 6295 Ferris Square Suite C San Diego, CA 92121 Tel: 858.537.3999 Fax: 858.537.3990 August 10, 2020 Grand Pacific Carlsbad Hotel, L.P. 5900 Pasteur Court, Suite 200 Carlsbad, California 92008 Attention: Mr. Houston Arnold MTGL Project No: 1916A16 MTGL Log No: 20-1233 ORANGE COUNTY CORPORATE BRANCH 2992 E. La Palma Avenue Suite A Anaheim, CA 92806 Tel: 714.632.2999 Fax: 714.632.2974 INLAND EMPIRE 14467 Meridian Parkway Building 2A Riverside, CA 92518 Tel: 951.653.4999 Fax: 951.653.4666 www.mtglinc.com Subject: RESPONSE TO REVIEW COMMENTS Sheraton Hotel 6 5410 Grand Pacific Drive Carlsbad, California Reference: MTGL, Inc. (2020). Geotechnical Investigation, Sheraton Hotel 6, 5420 Grand Pacific Drive, Carlsbad, California, MTGL Project No. 1916A16, Log No. 19-2317, February 6, Revised August 10, 2020 Hetherington Engineering, Inc. 2020, Third Party Geotechnical Review (Second), Proposed Hotel Building, 5420 Grand Pacific Drive, Carlsbad California, Project ID: CT15-08, dated July 20 Dear Mr. Arnold: As requested, this letter presents our responses to the review comments presented in the referenced Hetherington Engineering, Inc. review document. The review comments are presented in order from the review document, with our responses following each comment. The Consultant should review the project grading and foundation plans, provide any additional geotechnical recommendations considered necessary, and confirm that the plans have been prepared in accordance with the geotechnical recommendations. Response: we will review the final versions of the project grading and foundation plans when they are made available to us and confirm that they have been prepared in accordance with our geotechnical recommendations. The Consultant should address whether the site is considered a "Near Fault Site" in accordance with Section 11.4.1 pfASCE 7-16. Response: This issue is addressed in paragraph 2.04 on page 5 of the referenced revised report. OCILA/INLAND EMPIRE DISPATCH 800.491.2990 SAN DIEGO DISPATCH 888.844.5060 Sheraton Hotel 6 MTGL Project No. 1916A16 San Diego. California MTGL Lop No. 20-1233 The Consultant should provide the site Risk Category and Seismic Design Category consistent with the 2019 California Building Code. Response: This issue is addressed by paragraph 3.02 of the referenced revised report. The Consultant should provide a statement confirming that the foundation and slab recommendations are consistent with the requirements of Section 1808.6 (expansive soils) of the 2019 California Building Code or revise the recommendations accordingly. Response: the foundation and slab recommendations of the referenced report are consistent with the requirements of Section 1808.6 of the 2019 California Building Code. We appreciate this opportunity to be of continued service to you. Should you have any questions regarding the information contained herein, please contact us at your earliest convenience. Respectfully submitted, MTGL, Inc. Sthphen J. rtoov.9f, RCE, GE Vice Preside Chief Engineer Page 2 of 2