HomeMy WebLinkAboutCT 15-08; STRUCTURAL CALCULATIONS; 2020-03-04'4
13NIIE
STRUCTURAL • CIVIL • SUR VL.. LAND PLANNING
9449 Balboa Avenue, Suite 270 • San Diego, CA 92123
Phone (619) 299-5550 • Fax (619) 299-9934
www.bwesd.com
ENGINEER: Dane Hansen
DATE: March 4, 2020
PROJECT NUMBER: 12215A.3.00
STRUCTURAL CALCULATIONS
FOR
Carlsbad Ranch, P.A. NO.5
(Marbrisa - Phase III)
PUD 15-16/SDP 03-02A/CDP 03-04A/CUP 03-01A
HOTEL 6 RETAINING WALL
5410 Grand Pacific Drive
CARLSBAD, CALIFORNIA 92008
cFESS,oA
fi2CE 'VD
APR 072020
LAND DEVELOPMENT
ENGINEERING
DATE SIGNED: 03/04/2020
Prepared for
GRAND PACIFIC RESORTS, INC.
5900 PASTEUR CT, #200
CARLSBAD, CALIFORNIA
j
Adjacent Footing Load
Footing Width
Eccentricity
Wall to Ftg CL Dist
Footing Type
Base Above/Below Soil
at Back of Wall
Poisson's Ratio
= U.Olb
= 0.00 ft
= 0.00 in
= 0.00 ft
Line Load
0.0 ft
0.300
Project Name/Number brisa hote
RetainPro (c) 1987-2019, Build 11.20.02.28 License: KW-06056430 Cantilevered Retaining Wall Code: CBC 2016,ACI 318-14,ACI 530-13 License To: BURKETT AND WONG ENGINEERS
I Criteria I I Soil Data I I ------ I
Retained Height = 9.41 ft
Wall height above soil = 0.00 ft
Slope Behind Wall = 0.00
Height of Soil over Toe = 30.00 in
Water height over heel = 0.0 ft
Surcharge Loads
Surcharge Over Heel = 0.0 psf Used To Resist Sliding & Overturning
Surcharge Over Toe = 0.0 psf
Used for Sliding & Overturning
I Axial Load Applied to Stem
Axial Dead Load = 0.0 lbs
Axial Live Load = 0.0 lbs Axial Load Eccentricity = 0.0 in
Earth Pressure Seismic Load •
Method : Uniform
Multiplier Used = 18.000
(Multiplier used on soil density)
I Design Summary
Wall Stability Ratios
Overturning = 2.12 OK
Sliding = 2.76 OK
Total Bearing Load = 7,704 lbs
...resultant ecc. = 21.69 in
Allow Soil Bearing = 3,000.0 psf
Equivalent Fluid Pressure Method
Active Heel Pressure = 40.0 psf/ft
Passive Pressure = 900.0 psf/ft
Soil Density, Heel = 110.00 pcf
Soil Density, Toe = 0.00 pcf
FootingilSoil Friction = 0.350
Soil height to ignore
for passive pressure = 12.00 in
Lateral Load Applied to Stem •
Lateral Load = 0.0 #Ift
...Height to Top = 0.00 ft
...Height to Bottom = 0.00 ft
Load Type = Wind (W)
(Service Level)
Wind on Exposed Stem = 0.0 psf
(Service Level)
Uniform Seismic Force = 205.380
Total Seismic Force = 2,343.386
Stem Construction • -
Design Height Above Ftg ft =
Wall Material Above "Ht" =
Design Method =
Thickness =
Reber Size =
Reber Spacing =
Reber Placed at =
Design Data
th/FB+fa/Fa =
Total Force @ Section
Service Level lbs =
Strength Level lbs =
Moment .... Actual
Service Level ft-# =
Strength Level ft-# =
Moment.....Allowable ft-# =
Shear ..... Actual
Service Level psi =
Strength Level psi =
Shear.....Allowable psi =
Met (Masonry) in2 =
Reber Depth 'd' in =
Masonry Data
Soil Pressure @ Toe = 2,826 psf OK
Soil Pressure @ Heel = 0 psf OK
Allowable = 3,000 psf
Soil Pressure Less Than Allowable
ACI Factored @ Toe = 3,957 psf
ACI Factored @ Heel = 0 psf
Footing Shear @ Toe = 19.8 psi OK
Footing Shear @ Heel = 24.6 psi OK
Allowable = 82.2 psi
Sliding Caics
Lateral Sliding Force = 4,244.1 lbs
less 100% Passive Force = - 8,662.5 lbs
less 100% Friction Force - 3,065.6 lbs
Added Force Req'd = 0.0 lbs OK
....for 1.5 Stability = 0.0 lbs OK
Bottom
Stem OK
0.00
Masonry
ASD
16.00
#5
8.00
Edge
2nd
Stem OK
4.00
Masonry
ASD
8.00
#5
8.00
Edge
0.979 0.996
1,696.5 3,703.6
4,061.1 14,647.9
4,144.4 14,692.9
18.5 19.8
51.7 52.5
91.50 187.50
5.25 13.00
fm - psi = 2,000 2,000
Fs psi = 32,000 32.000
Vertical component of active lateral soil pressure IS Solid Grouting = Yes Yes NOT considered in the calculation of soil bearing Modular Ratio 'n' = 16.11 16.11
____________________________ Wall Weight psf = 78.0 164.0 Load Factors Short Term Factor = 1.000 1.000 Building Code CBC 2016,ACI Equiv. Solid Thick. in 7.60 15.60 Dead Load 1.200 Masonry Block Type = Medium Weight Live Load 1.600 Masonry Design Method = ASD Earth, H 1.600 Concrete Data Wind, W 1.000 fc psi = Seismic, E 1.000 Fv rii =
Project Name/Number •brisa hote
License: KW-08056C License To: BUR
I Footing Data
NEERS Cantilevered Retaining Wall
Footing Design Results
Code: CBC 2016,ACI 318-14,ACI 530-13
Toe Width = 2.00 ft
Heel Width = 5.25
Total Footing Width = 7.25
Footing Thickness = 24.00 in
Key Width = 12.00 in
Key Depth = 0.00 in
Key Distance from Toe = 2.00 ft
fc = 3,000 psi Fy = 60,000 psi Footing Concrete Density = 150.00 pcf
Min. As% = 0.0018
Cover @ Top 2.00 @ Btm.= 3.00 in
Ift had
Factored Pressure = 3,957 0 psf
Mu': Upward = 83,345 1,150 ft-#
Mu': Downward = 22,080 20,991 ft-#
Mu: Design = 5,105 19,841 ft-#
Actual 1-Way Shear = 19.76 24.55 psi
Allow 1-Way Shear = 82.16 82.16 psi
Toe Reinforcing = #6 @ 8.00 in
Heel Reinforcing = #6 @ 8.00 in
Key Reinforcing = None Spec'd
Footing Torsion, Tu = 0.00 ft-lbs
Footing Allow. Torsion, phi Tu = 0.00 ft-lbs
If torsion exceeds allowable, provide
supplemental design for footing torsion.
Other Acceptable Sizes & Spacings
Toe: #4@ 4.62 in, #5@ 7.17 in, #6@ 10.18 in, #7@ 13.88 in, #8@ 18.28 in, #9@ 23.
Heel: #4@ 4.62 in, #5@ 7.17 in, #6@ 10.18 in, #7@ 13.88 in, #8@ 18.28 in, #9@ 23.
Key: No key defined
Min footing T&S reinf Area 3.76 in2
Min footing T&S reinf Area per foot 0.52 in2 ift
If one layer of horizontal bars: If two layers of horizontal bars:
#4@ 4.63 in #4@ 9.26 in
#5@ 7.18 in #5@ 14.35 in
#6@ 10.19 in #6@ 20.37 in
I Summary of Overturning & Resisting Forces & Moments
OVERTURNING RESISTING Force Distance Moment Force Distance Moment Item lbs ft ft-# lbs It ft-#
HL Act Pres (ab water thl) 2,603.8 3.80 9,903.0
HL Act Pres (be water thl)
Hydrostatic Force
Buoyant Force =
Surcharge over Heel =
Surcharge Over Toe =
Adjacent Footing Load =
Added Lateral Load =
Load @ Stem Above Soil =
Seismic Earth Load = 1,640.4 5.71 9,358.3
Total = 4,244.1 O.T.M. = 19,261.3
Resisting/Overturning Ratio = 2.12
Vertical Loads used for Soil Pressure = 7,703.9 lbs
If seismic is included, the OTM and sliding ratios may be 1.1 per section 1807.2.3 of IBC.
Vertical component of active lateral soil pressure IS considered in the
calculation of Sliding Resistance.
Vertical component of active lateral soil pressure IS considered in the
calculation of Overturning Resistance.
Soil Over HL (ab. water thl) 4,054.1 5.29 21,453.2
Soil Over HL (bel. water thl) 5.29 21,453.2
Watre Table
Sloped Soil Over Heel =
Surcharge Over Heel =
Adjacent Footing Load =
Axial Dead Load on Stem =
* Axial Live Load on Stem =
Soil Over Toe = 1.00
Surcharge Over Toe =
Stem Weight(s) = 1,078.0 2.54 2,734.0
Earth @ Stem Transitions= 396.7 3.00 1,190.2
Footing Weighi = 2,175.0 3.63 7,884.4
Key Weight = 2.50
Vert. Component = 1,054.9 7.25 7,647.9
Total = 8,758.7 lbs R.M.0 40,909.6 * Axial live load NOT included in total displayed, or used for overturning resistance, but is included for soil pressure calculation.
Project Name/Number brisa hote
RetainPro (c) 1987-2019, Build 11.20.02.28
License: KW-06056430 Cantilevered Retaining Wall Code: CBC 2016,ACI 318-14,ACI 530-13 License To: BURKETT AND WONG ENGINEERS
Horizontal Deflection at Too of Wall due to settlement of soil
(Deflection due to wall bending not considered)
Soil Spring Reaction Modulus 250.0 pci
Horizontal Defi @ Top of Wall (approximate only) 0.102 in
The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe,
because the wall would then tend to rotate into the retained soil.