HomeMy WebLinkAboutPS 2021-0007; UNION BANK; Sign Permits/Programs (PS)Ccicyof
Carlsbad
JAN 2 j 2021
CITY Of CARLSBAD
P!__fl.NN f\•~: ')''PS!ON
REVIEW FOR
SIGN PERMIT
P-11/
PLANNING AP
Development Services
Planning Division
1635 Faraday Avenue
(760) 602-4610
www.carlsbadca.gov
REC'D BY --=~::..=:....:::~~'--""'..i:t.AA,µ~..:.::::1.t---
DA TE____.,\ ....... -E+-~----------SIGN FEE_ ........ ..__ _________ _
SIGN PROGRAM FEE ----------RECEIPT NO. ___________ _
NOTE: AN APPOINTMENT IS REQUIRED FOR SUBMITTAL. PLEASE CONTACT THE APPOINTMENT SPECIALIST AT (760) 602·
2723 TO SCHEDULE AN APPOINTMENT. *SAME DAY APPOINTMENTS ARE NOT AVAILABLE*
All plans submitted for sign permits/sign programs shall consist of a minimum of a site plan and sign
elevations containing the following information:
1. North arrow and scale.
2. Location of existing buildings or structures, parking areas, and vehicular access points to the
property.
3. Location of all existing and proposed signs for the property.
4. Distance to the property line(s) for all proposed freestanding sign(s).
5. Provide an elevation for all proposed sign(s) which specifies the following:
A. Dimensions and area for all existing and proposed sign(s).
B. Materials the sign(s) will be constructed of.
C. Source of Illumination.
D. Proposed sign copy.
APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED
APPLICATION FORM, AND THE APPLICATION FEE. Average processing time: 2 weeks
Name of Project: Union Bank #745 Carlsbad Poinsettia
Address of Project: 7188 Avenuda Encinias Ste. 120 Carlsbad, Ca 92011-4602
Assessor Parcel Number: --'2"""'1'-4--4-'3--"0'--.a;..19'--""""0-'-0 _________________ _
Related Planning Case Number(S): ____________________ _
TYPE OF DEVELOPMENT:
(a) Residential (d)
@ Commercial (e)
(c) Office/Industrial (f)
Hotel/Motel
Service Station
Prof. Care
(g) Theater
(h) Gov'UChurch/School
(i) Public Park
0) Produce Stand
(k) Nursery
(I) P-U/0S Zone
SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA YesO No □
Specific Plan Number ____ _
VILLAGE REVIEW AREA (If yes. please complete information on page 3) Yes 0
SOUTH CARLSBAD COASTAL REVIEW AREA Yes 0
SIGN ORDINANCE: Yes 0 No □ COASTAL ZONE: Yes □No 0
P-11 Page 1 of 4
No □ No □
Rev. 02/28/18
EXISTING SIGNS:
TYPE NUMBER SIGN AREA SIGN HEIGHT
Pole
Monument 3 10.5
Wall 2 37
Suspended/Projecting 1 3
Directional
Canopy
Freestanding (Project Identity)
PERMITS ISSUED FOR EXISTING SIGNS: Yes O No O Date ______ _
PROPOSED PERMANENT SIGNS:
MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED
TYPE NUMBER PROPOSED SIGN SIGN AREA SIGN SIGN
ALLOWED AREA HEIGHT HEIGHT
Pole**
Monument** 3 10.5
Wall 2 35
Suspended/Projecting 1 3
Directional
Canopy
Freestanding**
(Project Identity)
Digital Display
PROPOSED TEMPORARY SIGNS:
MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED
TYPE NUMBER PROPOSED SIGN SIGN AREA SIGN SIGN
ALLOWED AREA HEIGHT HEIGHT
Construction**
For Sale**
Banner
Interim
**Prior to approval, all proposed pole, monument, and freestanding signs must be reviewed
for potential sight distance and visibility issues. Additional information must supplement
this application showing how the proposed signage will not encroach into the public right-of-
way or present a traffic hazard. Page 3 of 4 illustrates an example for what would be required
for such proposed signs.
P-11 Page 2 of 4 Rev. 02/28/18
SITE PLAN REQUIREMENT FOR POLE, MONUMENT, AND FREESTANDING SIGN
APPLICATIONS
The following example illustrates the information that is required for all pole, monument, and
freestanding sign permit applications. Prior to approval, all such proposed signs must be reviewed
for potential issues by the Transportation Department, which will not allow signs to be approved
over the counter. Additional time will be required for on-site inspection.
I I 1 I
PIL I Si&ht Dist:ce Requirement
Show buildins /1
/ :
' I
~---l Shaw setbacks from all curbs ---
' I I ' I I I Shaw all property lines I
P/1.. ' I
:_t I
curb line i
----------~--
• •
Sipt Vuibility I Street Name(s) (i) I
I Nortlt
21.41.080 Sign design standards
Relationship to Streets: Signs shall b,e designed and located so as not to interfere with the
unobstructed clear view of the public right-of-way and nearby traffic regulatory signs of any
pedestrian, bicyclist or motor vehicle driver.
Sight Distance: No sign or sign structure shall be placed or constructed so that it impairs the sight
distance requirements at any public or private street intersection or driveway.
EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA
Total Building Square Footage: sq. ft. ---------
Tot a I Building Street Frontage: linear ft.
Total Signage Allowance: sq. ft.
Existing Signage (sq. ft.): sq. ft.
Remaining Sign Allowance at Present: sq. ft.
Proposed Signage (sq. ft.): sq. ft.
Remaining Sign Allowance After Proposed Sign: sq. ft.
VILLAGE REVIEW AREA
Total Signable Area: sq. ft. ---------
Tot a I Signable Area Length: sq. ft.
Total Signable Area Height: sq. ft.
Total Projection from Wall Face: inches
P-11 Page 3 of4 Rev. 02/28/18
PROPERTY OWNER APPLICANT
NAME (PRINT OR TYPE) NAME (PRINT OR TYPE)
DONAHUE SCHRIBER REAL TY GROUP L P PETER LAPSIW ALA
MAILING ADDRESS MAILING ADDRESS
12925 El Camino Real J2-8 560 South Quince
CITY STATE ZIP TELEPHONE CITY STATE ZIP TELEPHONE
San Diego, CA 92130 (858) 793-5757 ESCONDIDO CA 92025 760-743-3103
I CERTIFY THAT I AM THE LEGAL OWNER I CERTIFY THAT I AM THE REPRESENTATIVE
AND THAT ALL THE ABOVE INFORMATION OF THE LEGAL OWNER AND THAT ALL THE
IS TRUE AND CORRECT TO THE BEST OF ABOVE INFORMATION IS TRUE AND CORRECT
MY KNOWLEDGE. TO THE BEST OF MY KNOWLEDGE.
/.f'yt!-12/18/20 ,~1',~J 12/16/2020
SIGNATURE DATE SIGNATURE DATE
PLANNER CHECK LIST:
1. Field check by planner.
2. Within maximum length, area.
3. Style consistent with Sign Program and/or Specific Plan criteria, if applicable.
4. Location: ❖ In right-of-way ❖ In visibility triangle at corner
5. Pole and monument signs to be checked by Transportation Engineering, for visibility issues.
6. When approved route copy to nt
Date: l / 2Z}2d~ i
P-11 Page 4 of4 Rev. 02/28/18
, •oocuSign Envelope ID: B5CE0A95-EE74-47FA-896O-367D5E8E718E
December 3, 2020
MUFG Union Bank, N.A.
Corporate Real Estate
1101 W. Washington Street, 3rd Floor
T-83-9664
Tempe, AZ 85281
RE: Sign Response for Union Bank
Poinsettia Village
Carlsbad, California
VIA ELECTRONIC DELIVERY ONLY
The sign submittal received at our office for the above-referenced project has been
reviewed and approved as noted. Please use the comments noted on the drawings and
the guidelines listed below to make any necessary adjustment to your documents and the
installation of your sign.
1. All signs shall be reviewed for conformance with the sign criteria and overall design
quality and is not a plan check for dimensional errors, code violations or any other
restrictions to the property. Approval or disapproval of sign submittals based on
aesthetics of design shall remain the sole right of the Landlord/Manager.
2. Prior to the installation and manufacture of any sign, the Tenant shall provide
Landlord with a copy of the sign permit from the governmental agency having
jurisdiction.
3. All building penetrations are to be properly sealed and weathertight. Installer
to contact Landlord for inspection upon completion.
4. Each tenant shall be responsible to repair any damage to any surface caused by
the signage or its' installation.
5. Landlord reserves the right to periodically hire an independent electrical engineer,
at Tenant's sole expense, to inspect the installation of all Tenants' signs. Tenants
shall be required to have any discrepancies and/or code violations corrected at
Tenant's expense. Any code violations, requests for sign removals, or
discrepancies not corrected within fifteen (15) days of notice, may be corrected by
the Landlord at Tenant's expense.
6. Upon vacancy, Tenant shall remove sign and restore fascia to original condition at
Tenant's sole cost and expense within fifteen (15) days of expiration of term or
earlier termination of Tenant's lease.
200 E. Baker Street
Suite 100
Costa Mesa, CA 92626
(714) 545-1400
FAX: (714) 545-4222
donahueschriber.com
Lie. 01875932
• • DocuSign Envelope ID: B5CE0A95-EE74-47FA-896D-367D5E8E718E
December 3, 2020
Union Bank -Poinsettia Village
Page2
7. Exposed junction boxes, transformers, lamps, tubing, conduit, or raceways of any
type are NOT PERMITTED.
8. Sign manufacturer's names, stamps, or decals may not be visible from the street or
normal viewing angles.
9. All signs must be pegged off wall ½" minimum.
10. Tenant's sign contractor shall install and connect sign display and primary wiring at
sign location approved by Landlord. Signs are to be connected to the J-box provided
by the Landlord, which is connected to the Landlord's house panel, and shall be
wired to Landlord's control at Landlord's timer for uniform control of hours of
illumination unless otherwise directed by Landlord.
11. Window Graphics -Prior to commencing any Tenant's Work at the Premises,
Tenant, at its sole cost and expense, shall professionally design, fabricate and install
window graphics covering its storefront windows ("Window Graphics") so that the
entire Premises storefront is covered and in such a manner so that any Tenant Work
performed in the Premises is not visible to the public. The Window Graphics shall
be subject to Landlord's prior written approval as to fabrication, design and content.
Tenant shall submit its Window Graphics over-all design proposal and the name of
its sign company to Landlord for review and approval at least seven (7) days prior
to the commencement of any Tenant Work in the Premises.
12. Prior to sign installation, we require the following:
a. A copy of your sign contractor's insurance certificate naming Donahue
Schriber Realty Group, LP and all related affiliates, as additional insured
(with additional insured endorsement page attached).
b. A copy of the permit and the contractor's license.
c. At least 48hour notice of date of install and requesting access to electrical
room, if required.
Should any other contractor provide installations or other work on the site, please
call me to coordinate insurance requirements.
In the event that the above information contradicts the lease signage criteria, the lease
signage criteria are to supersede. Should you have any questions, please call me at
858. 793.5752.
Sincerely,
DONAHUE SCHRIBER rv::sa;i~ b F~fflis\fflj)j'g
Director, Construction
cc: Tom Schriber Jr., DSRG
File
SIGN PERMITNO.OPf'ml-~7 , I DATE
PLANNING\ xe /~ \ '{¾tv\ \
' I
BUILDING
APN: 214-430-19-00
LEGAL: PAR 7\ PARCEL MAP NO 15187
CONT ACTOR:
MATTHEW SIGNS
560 S QUINCE STREET
ESCONDIDO CA 92025
LANDLORD:
DONAHUE SCHRIBER REAL TY GROUP L P
12925 El Camino Real J2-8
San Diego, CA 92 130
SCOPE OF WORK:
-n1on an
SITE ADDRESS:
Carlsbad Poinsettia
7188Avenida Encinas Ste 120
Carlsbad, CA 92011
ALL WORK TO COMPLY WITH:
2019 CALIFORNIA BUILDING CODE
2019 CALIFORNIA ELECTRICAL CODE
TO INSTALL (2) ILLUMAINTED WALL SIGN (3) TENANT PANELS ON EXISTING MONUMENT
SIGNS AND (1) PANEL ON EXISTING BLADE SIGN
• I
SITE PLAN
Scale : not to scale
Stratus,.
stratusunlimited.com
i-"',?::? T·1l•, r [-r u k ·.'U'll
r,'.,_•r't\.J, .~ t J 1,.: ·_>AJ
888.5 03 1569
CLIENT:
IJ UnionBank
ORDER NUMBER:
1146696
PROJECT NUMBER:
5128
Rev #
Original
Rev1 -.
Req# Dote/Artist I Descri£_tion Rev# I Reg_# I Dote/ArtistJ [)escription
332125 11/06/20 SC
332333 11/12/20 SC
332574
332801
Rev4 332!
. 333124
SITE NUMBER: I PROJECT MANAGER: I Rev 2 I -~---------111111! .. ~--tl I Rev 3 , I______ •-·--··-n7AI; T"nv:>C:rnlt I 1~~~~8 1 1~~~/~~~~1 I I I I I
Carlsbad Poinsettia I ELECTRONIC FILE NAME: I Rev 5 I 333632 7188 Avenida Encinas Ste 120 2 K:\ART\ACCOUNTSIU\Union Bank\LOCATIONS\2020\CA\ I Rev 6 I
Carlsbad, CA 92011 0745_CARLSBAD POINSETTIA\0745_Carlsbad Poinsettia R5
SOUTHWEST ELEVATION -CUSTOM AW.3
Scale: 3/16"=1 '-0"
63'-0" STOREFRONT-----------
f-------20'-2"--------t
c/1
c/1 4'-3"
25'-0"
OAH
Stratus'" CLIENT: ORDER NUMBER:
1146696
PROJECT NUMBER:
5128
Rev# I Re.9. # I Date/Artist I [)_escript ion
IJ UnionBank , • SITE NUMBER: PROJECT MANAGER: Rev 2 332574 11/20/20 SC
OriQinal I 332125 I 11/06/20 SC
Rev 1 I 332333 I 11/12/20 SC
EXISTING CONDITIONS
Existing 2'-6" x 14'-10" signage to be removed;
wall repaired as necessary prior to new install.
Paint color SW 6116
ALLOWABLE SF: 39
EXISTING SIGN SF: 37.1
PROPOSED SIGN SF: 35.9
Rev# I Re.9. # I Date/Artist I Description
stratusu nlimited .com
---• PAGE NO.: I 0745 Tanya Scott Rev3 332801 11/25/20SC I Added as option
_ Rev 4 332948 12/01/20 KP I Remove OPT.A& OPT.B I I I I
ELECTRONIC FILE NAME: Rev 5 333124 1?tnR!?n KP I I I I I i ADDRESS:
Carlsbad Poinsettia E?~9 Tvl,__.r f:i_'Lil•--,;u•d
t,h-1'tcr, "; •.) 4 4 :::'t~C
888.503 .1569
7188 Avenida Encinas Ste 120
Carlsbad, CA 92011
3 K:IART\ACCOUNTS\U\Umon Bank\LOCATIONS\2020\CA\
0745_CARLSBAD POINSETTIAI0.745_Carlsbad Poinsettia R5
SOUTHEAST ELEVATION · CUSTOM AW.3
Scale : 1/8"=1 '-0"
20'-0"
I ±4'-4" c,1 ---
7'-10"
CLIENT:
22'-4"
c/1
IJ UnionBank
ORDER NUMBER:
1146696
SITE NUMBER;
PROJECT NUMBER:
5128
PROJECT MANAGER
Rev#
Oriainal
Rev 1
Rev2
Req# Dote/Artist J Description
332125 11/06120 SC
332333 11/12/20 SC
332574 11/20/20 SC
Existing 2'-6" x 14'-10" signage to be removed;
wall repaired as necessary prior to new install.
Paint color Flat White
ALLOWABLE SF: 57
EXISTING SIGN SF: 37.1
PROPOSED SIGN SF: 35.9
Rev# I Req # I Dote/Artist! Description
ADDRESS:
Carlsbad Poinsettia
7188Avenida Encinas Ste 120
Carlsbad, CA 92011
PAGF NO.: I 0745 I Tanya Scott -Uau• 'nsn•~~~lZ/~U!_!ll~ZU~K~t''._j.~~~em~o~ve~u:!t'~l:!;_,1'~6_:U~t'!.:_l,ll~----------1---+---!f----f----------------,
____ 4 12/08/20 KP ELECTRONIC FILE NAME:
Rev3 332801 11/25/20 SC I Added as ootion
Rev4 332948 12/01/20 Kn I o"-""" "OT•• "□TD
Rev 5 I 33312·
4 K:IART\ACCOUNTS\U\Union Bank\LOCATIONS\2020\CAI
0745_CARLSBAD POINSETTIA\0745_Carlsbad Poinsettia R5
FACE LIT CHANNEL LETTERS -WHITE -AW.3
Scale: 1/2"=1 '-0" 35.9 square feet
I 14'-4-3/8"
~2·-0·1 1------------11 '-5-1/2"--------------l
r
2'-6"
L OJJ Uu □@Uu [B@ UiJ lk ]·
LOGO FACES:
Simulated night time view
WALL
TYPE CMU, BRICK PRE-CAST CONCRffi.
CONCRETE
PREFERRED FOR ALL
WALL TYPES WHEN
POSSIILE
EIFSWALL WI
FOAM INSULATION
SECTION ee._ ...• . . . . ~ ... . . , : : ....
' . '
ANCHOR
TYPE
0112" SLEEV ANCHOR
(0318" BOLT),~ MIN.
EMBEOMENT
0318" EXPANSION
ANCHOR, 2 112" MIN.
EMBEDMENT
0114"-318" THREADED ROD
01/4"-3/B' THREADED ROD I WI ALUMINUM OR PVC
COMPRESSION SLEEVE 3/16" th ick #015-2 white acrylic ( or equivalent) w/ 1st surface
vinyl decoration. ~---<COLOR PALETTE f-----
LETTER FACES:
TRIMCAP:
RETURNS:
BACKS:
ILLUMINATION:
3/16" thick #015-2 white acrylic (or equivalent).
1" jewelite painted to match PMS 8400 Metallic
2" jewelite trimcap for letters over 42"
3" deep .063 alum. painted to match PMS 8400 Metallic
.063 alum. backs -insides pre-finished white
Illuminate logo w/ red Tetra max LEDs; Illuminate letters w/ 71 00k
white Minimax LEDs, four (4) modules per foot per LED layout;
Remote power supplies.
•
0
e
LO.G.Q:
3M 3630-73 Dark Red
Translucent Vinyl
LETTERS·
white acrylic
RETURNS & TRIMCAPS·
Paint to match
PMS 8400 Metallic
WALL MATERIAL: NOT PROVIDED AT THIS TIME
INSTALL:
NOTE:
Preferred install is thru bolted flush to wall surface using min
1/4" all thread fasteners; blocking as required
Landlord requires "a minimum of 2 different lighting techniques, i.e. reverse channel neon, internal
illumination, channel letters (wall signs)" All decals, except permit sticker, may not be placed where
visible from normal viewing angles. Channel letters shall have a 5" maximum letter depth and
1/4" stand-off from wall. Weep holes to be baffled. Per Don Armstrong with landlord, standard
channel letters may be submitted for approval as a like-for-like replacement.
Per Sign Plan with City of Carlsbad -Max letter height of 36".
Sides of lettering must be bronze. (Existing returns are silver.)
Stratus'" CLIENT:
IJ UnionBank
ORDER NUMBER
1146696
SITE NUMBER:
PROJECT NUMBER:
5128
PROJECT MANAGER:
Rev# Req#
Original 332125
Rev 1 332333
Rev 2 332574
.0401hk. alum. ~ bridge cover
paint to match
~ y
TYPICAL BRIDGE DETAIL
NOlTOS(;AlE
Dote/Artistl Description
11/06/20SC
11/12120 SC
11/20/20 SC
114' -112" Noo-<:orrosive •• ~ lli::!11 IIII Al thread fastener--l l k!Afi
Toggle bolts'----~
Power supply, ____ _
housing r-i-
Electronic pcwer ----'~--
Aluminum returns
Trim cap
-----Riv-nut
Acrylic face
supply
@Lis~disconnect /'
I mr II Aluminum backs lfi, _ _,_,._, ----LED illumination
switch
Greenfield conduit ½•minimum
~ II 12vottjacketedcable
Primary electrical soorce
LED CHANNEL LETTERS -
REMOTE
NOT TOSCA.LE
Rev# I Req # I Dote/Artist I Description
Weep holes y.-dia.
exteri0< locations only
r."\-.. _...,._.,~.-.. ,~•-.:.· I~.:::::::..-:S=::!.W.:. I -\!Y-=-~~~~-
st ratusunlimit ed.com ADDRESS: oAr-rn". ■ 0745 --, ----I ~ev ~ I ::~~~~ I ~~~~~~~~~ I Remove OPT.A& OPT.B I I I I I Tanya Scott Rev 3 332801 11/25/20 SC Added as option
Rev4 332948 12101/20 KP Remove OPT.A& OPT.B
Rev 5 333124 12108/20 KP Remove TBD notes on trim caps and returns. 8?sq T/l:.:··r bculcvord
f,h_'t'lC·r, "='t-' ,::, 44260
888.503.1569
Carlsbad Poinsettia
7188Avenida Encinas Ste 120
Carlsbad, CA92011
5
ELECTRONIC FILE NAME:
K:IART\ACCOUNTSIU\Union Bank\LOCATIONS\2020\CA\
0745_CARLSBAD POINSETTIA\0745_Carlsbad Poinsettia R5
Rev 6 333632 12122120 TB
NON-ILLUMINATED BLADE FACE REPLACEMENTS
Scale: 3" = 1 '-0"
1 '-1/2"
TRIM SIZE
i----------------2'-10-1/2" TRIM SIZE ----------------1
r
4-3/4"
l Union Bank
OVERALL SIZE: 1 '-2" x ±3'-0"
FACE: 1/2" thick Sintra faces
GRAPHICS: Surface applied vinyls to match colors shown
QUANTITY: (2) two faces required for d/f blade sign, attachment TBV
NOTE: Material required by landlord
Rubbing of face for radius ends prior to manufacturing
COLOR PALETTE
0 ~~~~~0-73 Dark Red
Translucent Vinyl
• LETTERS·
3M Translucent Vinyl
to match PMS Cool Gray 11 C
Stratus'· CLIENT:
IJ UnionBank
ORDER NUMBER:
1146696
PROJECT NUMBER:
5128
Rev # I Req # I Dote/Artist I Description
Original I 332125 I 11106/20 SC
Rev1 1332333 l1111212osc
SITE NUMBER: PROJECT MANAGER: Rev 2 332574 11/20/20 SC
strotusunlimited.co m
2.'?S? T·il~ r Ecuk•;ord
r,,k'r'tcr, ~r, ·:J 44:.,'b(J
888.1:<)3.1569
Rev 3 332801 11/25/20 SC
ADDRESS: PAGE NO.: 0745 Tanya Scott Rev4 332948 12/01/20KP
Carlsbad Poinsettia ELECTRONIC FILE NAME: Rev 5 333124 12/08/20 KP
7188Avenida Encinas Ste 120 6 K:IART\ACCOUNTS\U\Union Bank\LOCATIONS\2020\CA\
Carlsbad, CA 92011 0745_CARLSBAD POINSETTIA\0745_Carlsbad Poinsettia RS
Remove faces from 0/F blade
sign, install new faces.
pRnPnSFn Sl~NA~F • . . . .
Rev # I Req # I Dote/Artist I Descrip_tion
REPLACEMENT TENANT PANELS
Scale: 1-1/2"=1 '-0" 3.1 square feet
t-----------3'-5-7/8"-----------1
1,--
I0-~4"
6L IJ UnionBank L1= •· •···
FACES:
GRAPHICS:
.090 pan formed alum. w/ 1-1 /4" returns on all sides
Routed from alum face; push thru 3/4" clear acrylic w/ 1/2" projection;
Logo to have surface applied trans red vinyl; letters to have surface
applied dual color film printed grey-to illuminate white at night.
ATTACHMENT: Countersunk screws thru side returns, fastener heads painted to match.
QUANTITY:
NOTE:
(2) TWO faces required for two S/F monuments
Landlord required materials: Sto textured aluminum
tenant panels, Pop-through acrylic lettering.
Landlord to provide background paint color for panels.
CLIENT:
IJ UnionBank
ORDER NUMBER:
1146696
~-----l C_QLOij_eALETTE
• ~~~~~0-73 Dark Red
Translucent Vinyl
LETTERS: • 3M perforated dual color film
to match PMS Cool Gray 11 C
/0\ fACE.:. V CZ-1 17-690
Main Stucco
Frtiffl Paint (-1171
f040A'lt~~
Ga'IAl,Nl,c:Atn:li
10/Jt :l.! l~!~~!!i
200 OORATEC II fl.AT
~~WH'ltt~llot ~ r n111m1a11
l'Mttne llUDIIIH_~~
~ Q·,1~.c n,u
t OY l.i~~tti
L bY 'l, t:JQI U
t:-; Qtl-(. ~:,\!/.,
COLOJf
JO I Gz.11J'6fl ~ ■-• MMHS11JCCO C,41Q; 1GA!J.Qh
ti!>: l !G
N.o1:a1 lilt,:; iM:(
aaCI. ITf.!111 Uf'Ol!II ........ ~'tll;!III ~not~ ~J iqt ar.ml5mll
ROUTED-PUSH THRU LETTERS NOT TO SCALE
Aayticpushthru
letters • resin bonded
to acrytic backer
PROJECT NUMBER:
5128
Rev#
Oriqinal
Rev 1
n ___ ,..
··--
Req#
332125
332333
332574
Dote/Artist! DescriJ).tion
11/06/20 SC
11/12120 SC
Remove faces from S/F monument
sign, install new faces.
PROPOSED SIGNAGE • scaled proportionally
_'PJP.!15 ")
fresh fare
Rev# I Req # I Dote/Artist I DescriR.tion
Stratus'·
stratusunlimited.com
8959 Tyler E:-culc•,ord
Lh_•1·tcr. ·"t, •_) ~~JGO
I PROJECT MANAGER: I Kev 2 I :""'" ' '"""'"" M
T~""~ "M" 1Rev3 \ ___
1
·-
1
! I 1 ~1~~
Carlsbad Poinsettia I ELECTRONIC FILE NAME: I Rev 5 I \ \
·-332801
Rev4 3321
1333124
888.503 1569
7188Avenida Encinas Ste 120 7 K:IART\ACCOUNTS\U\Union Bank\LOCATIONS\2020\CAI 1 Rev6 I
Carlsbad, CA 92011 0745_CARLSBAD POINSETTIA\0745_Carlsbad Poinsettia R5
, 333632
REPLACEMENT TENANT PANELS
Scale: 1-1/2"=1'-0" 4.2 square feet COLOR_ PALETTE • LQGQ_;_
1----------------------4'-4"-----------------------1
3M 3630-73 Dark Red
Translucent Vinyl
~ ...... .
FACES:
GRAPHICS:
.090 pan formed alum. w/ 1-1/4" returns on all sides
Routed from alum face; push thru 3/4" clear acrylic w/ 1/2" projection;
Logo to have surface applied trans red vinyl ; letters to have surface
applied dual color film printed grey -to illuminate white at night.
ATTACHMENT: Countersunk screws thru side returns, fastener heads painted to match.
QUANTITY:
NOTE:
(2) TWO faces required for D/F monument
Landlord required materials: Sto textured aluminum
tenant panels, Pop-through acrylic lettering.
Landlord to provide background paint color for panels.
Stratus'· CLIENT:
IJ UnionBank
ADDRESS:
ORDER NUMBER:
1146696
SITE NUMBER:
0745
• LETTERS:
3M perforated dual color film
to match PMS Cool Gray 11 C
rc:3\EACE: V CZ-117-690
Main Stucco
Ff'll-H Paint I# 1171
7k0 Annidll ~
c..1SbMl,CA_R»I
l~/~tt1)_: l~!~:!:;
:Z:OJ OURATE.C II FLAT
~ wJbff.. oo; ~ l lllIIL'lliJllll
t"M:U'l C tlB&'fJ!lilH ~-
:; Ol•l.:: , C :r:-iiiJ
t. o·; i.1at ••
L In ;.~~QJ I$ ,:x 1aH, ::,;IQ i i 'l
CQLO~-
H>: ~. •l11'6fi ) •-1 MAlN STIJCCO
C-; IG,l,,LI.~
w : 1M
at, "1/h/l! •~
oma c:rw. a:roa .i.r~tu• ~ ~ ~ -•~ser:u:u
ROUTED-PUSH THRU LETTERS NOT TO SCALE
Acrylic push thru
letters -resin bonded
to aaylic backer
PROJECT NUMBER:
5128
PROJECT MANAGER:
Tanya Scott
~Aluminum Face
-s. __
----.
Rev# Req # Date/Artist I Descril)_tion
Oriainal 332125 11/06120 SC
Rev 1 332333 11/12/20 SC
Rev2 332574 11/20/20 SC J Updated clearspace
Rev3 332801 11/25/20SC
Rev4 332948 12/01/20 KP
Remove faces from D/F monument
sign , install new faces.
PROPOSED SIGNAGE • scaled proportionally
0
I, UnionBank
Rev# I Req # I Date/Artist I Description
stratusu nli mited.com
E?~? T'1L r EcuL:,,.:o•d
~ ... kr'tl,r :·r, , . .:i 4--:::_;oo
Carlsbad Poinsettia r:NO ELECTRONIC FILE NAME: Rev 5 333124 12/08/20 KP I Add background paint color
7188Avenida Encinas Ste 120 K:IART\ACCOUNTSIU\Union Bank\LOCATIONS\2020\CA\ Rev6 333632 12/22/20 TB
888.503 1569 Carlsbad, CA 92011 0745_CARLSBAD POINSETTIA\0745_Carlsbad Poinsettia R5