Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
7100 AVIARA RESORT DR; ; FPC2018-0136
(hty of PERMIT REPORT Carlsbad Print Date: 09/07/2023 Permit No: FPC2018-0136 Job Address: 7100 AVIARA RESORT DR, CARLSBAD, CA 92011-4908 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2157500100 Track #: Applied: 05/07/2018 Valuation: $85,717.93 Lot #: Issued: 05/24/2018 Occupancy Group: Project #: Finaled Close Out: 03/19/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check #: INSPECTOR: Fier!, Dominic Plan Check #: Wong, Cindy Project Title: Description: TRAVEL TRADERS AT PARK HYATT AVIARA -FIRE ALARM TI -NEW STROBE AND SPEAKER STROBEDEVICES Applicant: RED HAWK FIRE AND SECURITY CA LLC ROBERT HASTINGS 920 S ANDREASEN OR, # 102 ESCONDIDO; CA 92029-1936 (760) 233-9787 FEE AMOUNT FIRE TI Fire Alarm System $601.00 Total Fees: $601.00 Total Payments To Date: $601.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov FPC20I8-0136 7100 AVIARA RESORT DR TRAVEL TRADERS AT PARK HYATT AVIARA - FIRE ALARM TI - NEW STROBE AND SPEAKER STROBE DEVICES 2157500100 6/1112019 FPC20I8-0136 FIRE ALARM TENANT IMPROVEMENT SUBMITTAL For TRAVEL TRADERS PARK HYATT AVIARA RESORT 7100 AVIARA RESORT DRIVE, CARLSBAD, CA 92011 Submitted By: Red Hawk Fire & Security 920 South Andreasen Drive, Suite 102, Escondido, California 92029 (760) 233-9787 PROJECT INFORMATION SHEET PERMIT NUMBER: INSTALLING CONTRACTOR: Red Hawk Fire & Security 920 South Andreasen Drive, Suite 102, Escondido, California 92029 Phone: (760) 233-9787 CONTRACTORS LICENSE: C-10/C-16 #713099,11/30/18 PROJECT MANAGER: Greg Cox PROJECT NAME: TRAVEL TRADERS PARK HYATT AVIARA RESORT PROJECT ADDRESS: 7100 AVIARA RESORT DRIVE, CARLSBAD, CA 92011 SCOPE OF WORK: FIRE ALARM SYSTEM TENANT IMPROVEMENT May 4, 2018 Re: Travel Traders Park Hyatt Aviara Resort 7100 Aviara Resort Drive, Carlsbad, CA 92011 Fire Alarm System - Tenant Improvement Red Hawk Fire & Security is pleased to submit the following equipment for your approval. All equipment is U.L. approved and California State Fire Marshall listed. The building is 100% sprinklered. OTY. MODEL NO. DESCRIPTION C.S.F.M. 3 GCF-VM Multi Candela Strobe, Ceiling Mt 7125-1657:0219 2 GCHFWF-S7VMC Multi Candela Speaker Strobe, Ceiling Mt 7320-1657:0324 Notes: The existing Booster Power Supply is manufactured by EST and is compatible with all new devices. Life safety speakers are tapped at 1/2W. Respectfully Submitted, RED HAWK FIRE & SECURITY EDWARDS Catalog 1> Strobes, Horns, Bells, Chimes United Technologies LIFE SAFETY INCIDENT MANAGEMENT Field Configurable,> Ceiling Strobes \ One or more patents pending. [IILL -"i- FC MEA ( ( 7125-1657: 0219 S5389 Overview Genesis life safety and mass notification/emergency communica- tions (ECS/MNS) ceiling strobes are small, compact, and attractive Visible emergency signaling devices. Protruding no more than 1.6" (41 mm) from the ceiling, Genesis strobes blend with any decor. Thanks to patented breakthrough technology, EDWARDS Gen- esis strobes do not require bulky specular reflectors and lenses. Instead, an exclusive cavity design conditions light to produce a highly controlled distribution pattern. Significant development efforts employing this new technology have given rise to a new benchmark in strobe performance - FullLight technology. Fulllight strobe technology produces a smooth light distribution pattern without the spikes and voids characteristic of specular reflectors. This ensures the entire coverage area receives consis- tent illumination from the strobe flash. As a result, Genesis strobes with FullUght technology go well beyond the minimum UL-required "cross" pattern, significantly exceeding UL-1 971 and ULC-S526 light distribution requirements. Depending on the model, clear lens Genesis ceiling strobes fea- ture 15 to 95, or 95 to 177 candela output (see ordering informa- tion), which is selectable with a conveniently-located switch. The candela output setting remains clearly visible even after final instal- lation, yet it is locked in place to prevent unauthorized movement after installation. Genesis ECS/MNS appliances offer emergency signaling with clear or amber lenses and with optional ALERT housing labels. They are ideal for applications that require differentiation between life safety and mass notification alerts. Standard Features Field configurable - no need to remove the device! - 15/30/75/95 cd and 95/115/150/177 cd clear strobe lens models available - Switch settings remain visible even after the unit is installed ECS/MNS models available - 13/26/65/82 and 82/100/130/155 (1971 equivalent) amber lens models available Unique low-profile design - 30 per cent slimmer profile than comparable signals - Attractive appearance - No visible mounting screws - Available with white or red housings Easy to install - Fits all standard 4" square electrical boxes with plenty of room behind the signal for extra wire - no extension ring or trim plate needed - #18 to #12 AWG terminals - ideal for long runs or existing wiring Unparalleled performance - Exclusive FullUght strobe technology produces the industry's most even light distribution - Precision timing electronics meet tough synchronizing standards for strobes - Low current draw minimizes system overhead Approved for public and private mode applications - UL 1971-listed as signaling devices for the hearing impaired - UL 1638-listed as protective visual signaling appliances - UL/ULC listed for ceiling or wall use Page 1 of 4 DATA SHEET E85001-0557 Not to be used for installation purposes. Issue 1 Application Genesis strobes are UL 1971 or 1638 listed for indoor use. Prevailing codes require strobes to be used where ambient noise conditions exceed specified levels, where occupants use hearing protection, and in areas of public accommodation. Consult with your Authority Having Jurisdiction for details. All Genesis strobes exceed UL synchronization requirements (within 10 milliseconds over a two-hour period) when used with a synchronization source. Synchronization for multiple strobe lights in a single field of view is required. ECS/MNS Applications Genesis ECS/MNS appliances bring the same high-performance life safety features and unobtrusive design to mass notification applica- tions. Available as standard units with clear or amber lenses with optional ALERT markings, thy are ideal for applications that require differentiation between life safety and ECS/MNS signals. Units are also available (special order) with red, blue or green lenses. Installation All models are intended for indoor applications only. Strobes mount to any flush North-American 4" square electrical box, 21/el (54 mm) deep. Genesis ceiling strobes simply unlatch and twist to open. This gains access to mounting screws and the selectable candela switch. The shallow depth of Genesis devices leaves ample room behind the signal for extra wiring. Once installed with the cover in place, no mounting screws are visible. Wiring Field wiring terminals accommodate #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wiring. Strobes are interconnected with a single pair of wires as shown below. + To listed To next fire alarm applia nee, control I end-of-line panel Lli I or return to + I control equipment Dimensions 6.8dia. I - (173 mm) •_•\ t (25 mm) O.6O15i) Light output (effective cd) Percent of UL rating versus angle - Percentage of rated output - -15---------- 15 0 Angle---- Horizontal and vertical outputs reflect the same pattern. Field Configuration Depending on the model, Genesis ceiling speaker-strobes have multi-candela output / candela switch (see ordering information). The output I setting is changed by simply opening the I device and sliding the switch to the desired I setting. The strobe does not have to be I removed to change the output setting. The setting remains visible through a small Indicator window on the front of the device after the cover is closed. WARNING: These deviceswill not operatewithout electrical power. Asflresfrequently cause power interruptions, we suggest you discuss further safeguards with your local fire protection specialist. Page 2 of 4 DATA SHEET E85001-0557 Not to be used for installation purposes. Issue I Light output setting, high output models 69 951 or "D" or 'C' or or "A" RMS RMS RMS RMS 333 392 499 551 259 303 378 429 212 245 306 342 155 180 211 236 484 570 673 724 380 438 537 604 318 361 434 484 245 269 308 338 Current Draw Light output switch settings for UL 1971 listed models are selectable by numeric candela value. ECS/MNS appliances are selectable by A, B, C, or D designations. Light output setting, standard models - - Light output setting, high output models UL or '30" or or 1I95 or "A" I "95" or "115" or or 61 77I or "A" Rating F RMS RMS RMS RMS RMS RMS RMS RMS 16Vdc 109 151 281 318 330 392 502 565 16Vfwr 131 194 379 437 432 518 643 693 Light output setting, standard models Typical 'f5"or "D" "30" or "C" "75" or "B" I "95" or "A" Current RMS RMS RMS T RMS 16Vdc 94 140 273 325 20 Vdc 74 108 205 244 2Vdc 631 90 168 194 33 Vdc 48 70 124 139 16Vfwr 126 187 368 403 20Vfwr 108 156 281 333 24Vfwr 97 139 240 270 33Vfwr 89 119 197 214 Current values are shown in mA. Specifications Textured UV stabilized, color impregnated engineered plastic. Exceeds 94V-0 UL flammability rating. Red and white models Housing available. Lens Optical grade polycarbonato (clear). Flush mount to North American 4-inch square electrical box, 2-1/8 (54 mm) inches deep. No extension ring required. Mounting Suitable for indoor wall or ceilinq applications. Wire Connections Screw terminals: #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wire size. Operating Voltage Regulated 16 to 33 Vdc, 16 to 33 Vfwr. Ooeratina environment Indoor: 32-120° F (0-49° C) ambient temperature; 0-93% relative humidity. Meets or exceeds year 2004 UL requirements for standards UL1638 and UL1971 and Canadian requirements for Agency listings/approvals standards CAN/ULC S526-02 and CAN/ULC S524-01. All models comply with ADA Code of Federal Regulation Chapter 28 Part 36 Final Rule. CSFM, MEA. FM. Strobe output rating UL 1971, UL 1638, ULC S526: selectable 15/30/75/95 cd (GC-VM) and 95/115/150/177 Cd (GC-VMH) GC-VM series strobes: non-coded, filtered 16-33 Vdc Strobe operating voltage or unfiltered 16-33 Vdc RNR. GC-VM series strobes: one flash per second synchronized with optional Gi M Genesis Signal Master indefinitely within 10 Strobe flash rate milliseconds. Temporal setting (private mode only): synchronized to temporal output of Genesis audible signals on same circuit. Meets or exceeds UL 1971 requirements. Maximum allowed resistance between any two devices is 20 Ohms. Refer Synchronization to specifications for the synchronization control module, this strobe, and the control panel to determine allowed wire resistance. SIGA-CC1S, SIGA-MCC1S, SIGA-CC2A, SIGA-MCC2A, G1M-RM Synchronization Sources BPS6A, BPS1 OA, APS6A, APS1 OA, 1064, i0500, Fireshield Plus 3, 5 and 10 zone. Add G1 M for G1-CVM &G1 -HDVM devices only. Page 3 of 4 DATA SHEET E85001-0557 Not to be used for installation purposes. Issue 1 Ordering Information E 1-3 WA DL Light output switch settings for UL 1971 listed models are selectable by numeric candela value. ECS/MNS appliances are selectable by A, B, C, or D designations. LIFE SAFETY & INCIDENT MANAGEMENT Model I Housing] Marking - Lens Strobe j Ship Wt. Life safety Appliances (ciw running man icon screen printed on housing) GC-VM White None Clear Selectable 15,30,75,0r95cd 1.81b. (0.82 kg.) EVMI White 'FIRE" GCFR-VM Red "FIRE" GC-VMH White None Selectable high output 95, 115, 150, or 177 cd GCF-VMH White I "FIRE" ECS/MNS Appliances (no running man icon on housing) GCWA-VMA White "Alert" Amber Selectable A, B, C, D 1.8 lb. (0.82 kg.) GCWA-VMC Clear GCWNVMA None Amber GCWN-VMC Clear GCWA-VMHA "AJert" Aniber I Selectable high output A, B, C or D Clear GCWA-VMHC Clear GCWN-VMHA None Amber GCWN-VMHC Units with red, blue or green lenses are available as a special order. Contact customer service for details. (ACE RT \ Contact us... Email: edwaws.fire@fs.utc.com Web: Edwards-flre.com EDWARDS is a UTC brand. 1016 Corporate Park Drive Mebane, NC 27302 © 2016 United Technologies Corporation. All rights reserved. Page 4 of 4 DATA SHEET E85001-0557 Not to be used for installation purposes. Issue 1 EDWARDS Catalog D Speakers, Telephones Technologies G United LIFE SAFETY g INCIDENT MANAGEMENT Ceiling Speakers, Speaker-Strobes -- - ... t• . .. .... MRT IRE FC11 EA FM 7320-1657: lvi 0211/0285 52813 See Specifications Section for listings details. Overview The Genesis line of ceiling life safety and emergency communica- tions speakers and speaker-strobes combine high performance output with a low profile design to deliver a life safety signal solu- tion that's as versatile as it is effective. While they are designed to mount inconspicuously overhead, these devices are also rated for wall-mounted applications. Clear-lens speaker-strobes are available in high and low candela models, which feature 15 to 95, or 95 to 177 cd output (see order- ing information). Ceiling speakers feature 1% W to 2 W operation, which allows devices to be easily fine-tuned to achieve maximum benefit in exchange for the lowest possible system overhead. Light output and wattage tap settings are selectable with conven- iently-located switches. Settings remain clearly visible even after final installation, yet they are locked in place to prevent unauthorized movement after installation. High fidelity models meet the NPFA 520 Hz requirements for newly construced commercial sleeping areas. They also produce crisp, clear voice audio output that is highly intelligible over large areas. These low-profile appliances feature textured housings in architec- turally neutral white or eye-catching life safety red. Optional ALERT or FIRE markings make them ideal for applications that require differentiation between life safety and mass notification alerts. Standard Features High Fidelity 520 Hz speaker models available Low frequency output meets NFPA standards for newly con- structed commercial sleeping areas; increases sound fidelity and audio intelligibility. Field configurable - no need to remove the device - Select 14, ½, 1, or 2 watt operation - 15/30/75/95 cd and 95/115/150/177 cd models available - Switch settings remain visible even after the unit is installed Ideal for Mass Notification applications - amber lens models available with optional ALERT markings Unique low-profile design - 30 per cent slimmer profile than comparable signals - Available with white or red housings Unparalleled performance - loud 90 dBA output ensures clear, crisp audio - Precision strobe timing meets UL synchronization standards - 25 VAMS and 70 VRMS models available Easy to install - Fits all standard 4-inch square electrical boxes with plenty of room for extra wire - no extension ring or trim plate needed - #18 - #12 AWG terminals - ideal for long runs, existing wiring Approved for public and private mode applications - UL 1971-listed as signaling devices for the hearing impaired - UL 1638-listed as protective visual signaling appliances - UL 1480-listed as life safety speaker - UL/ULC listed for ceiling or wall use Page 1 of 6 DATA SHEET E85001-0641 Not to be used for installation purposes. Issue 1 BOX Strobe Application Genesis strobes are UL 1971 or 1638 listed for indoor use. Prevailing codes require strobes to be used where ambient noise conditions exceed specified levels, where occupants use hearing protection, and in areas of public accommodation. Consult with your Authority Having Jurisdiction for details. All Genesis strobes exceed UL synchronization requirements (within 10 milliseconds over a two-hour period) when used with a synchronization source. Synchronization for multiple strobe lights in a single field of view is required. See the Specifications table for compatible synchronization sources. Speaker Application The suggested sound pressure level for each signaling zone used with alert or alarm signals is a minimum of 15 dB above the aver- age ambient sound level or 5 dB above the maximum sound level having a duration of at least 60 seconds, whichever is greater. This is measured 5 feet (1.5 m) above the floor. Doubling the distance from the signal to the ear will theoretically cause a 6 dB reduction in the received sound pressure level. The actual effect depends on the acoustic properties of materials in the space. Doubling the power output of a device (e.g.: a speaker from 1 W to 2 VV) will increase the sound pressure level by 3 dBA. A 3 dBA difference represents a barely noticeable change in volume. Combination audible/visual signals must be installed in accor- dance with guidelines established for strobes. High Fidelity Models Genesis G4HF Series High Fidelity appliances provide highly intel- ligible voice audio output. They are also effective in areas subject to high levels of ambient noise. These appliances are approved for use in sleeping areas under conditions described below. Sleeping Room Applications Genesis GCHF Series High Fidelity appliances are ideal for hotels, dormitories, and other residential occupancies where audible output must meet the 520 Hz signaling characteristics required by NFPA 72. In sleeping areas, always ensure that the wattage tap of the speaker is set sufficiently high so that the sound pressure reaches at least 75 dBA-fast at the pillow. These appliances are part of an end-to-end audio system ap- proved for use in sleeping areas when used in conjunction with approved audio hardware and a factory-supplied 520 Hz tone. Check the System Compatibility List for other 520 Hz signaling requirements. NOTE: Speakers driven by third-party audio systems are not UL approved for use in sleeping rooms Mass Notification Applications /ALERT Genesis Mass Notification appliances bring the same high-performance life safety features and unobtrusive design to mass notification applications. Models are available with optional ALERT housing labels, which make them ideal for applications that require differentiation between life safety and mass notification alerts. Application Notes - Canada (Based in part on 1995 Canada National Building Code) The signal sound pressure level shall not exceed 110 dBA in any normally occupied area. The sound pressure level from an audible signal in a floor area used for occupancies other than residential occupancies shall not be less than 10 dBA above ambient levels, and never less than 65 dBA. In sleeping rooms the sound pres- sure level from an audible signal shall not be less than 75 dBA when any intervening doors between the device and the sleeping room are closed. Installation and Mounting All models are intended for door ceiling or wall applica- tions only. Speaker-strobes are mounted to a flush North-American 4" square electrical box, 21/8 (54 mm) deep. Genesis ceiling speaker- strobes simply unlatch and hinge down to open. This gains access to mounting screws and the selectable candela wattage tap switches. The shallow depth of Genesis devices leaves ample room behind the signal for extra wiring. Once installed with the cover in place, no mounting screws are visible. Installation Note: When installed, these devices are not centered on the electrical box. Make sure boxes are mounted to compensate for this difference. Use the mount- ing template provided with installation sheet 3100614. Field Configuration Genesis ceiling speaker- strobes may be set for Y4, ½, (7 1, or 2 watt operation. De- pending on the model, Gen- Wattage switch indicator esis ceiling speaker-strobes have multi-candela output (see ordering information). Output settings are changed by simply opening the device and sliding the switches to the desired settings. The speaker-strobe does not have to be removed to change the output settings. The settings remain visible through small windows on the front of the device after the cover is closed. Dimensions 4 6.8"dia. (173 mm) - -- ------ - - ----- - - )(2m) in- Page 2ot6 DATA SHEET E850010641 Not to be used for installation purposes. Issue 1 Typical Sound Output (dBA) FfllFmInSpeM 121110 5 S 7 6 -t 4 3 2 101 2 5 4 5 8 7 .\ \ 5ft(1ttnl) - Radius Measured 0t2 watts setting In anecholc chamber Light output - (effective cd) - Precurdegs 111W_111 tratedoatpct - 1 12 95' -60 Percent of UL rating versus angle Hratzontd and nelted outputs redact the same pattern. 520 Hz Hiah Fidelity models IdBA1 outout at 3.05 m 110 11.1 25 VRMS 14W 0.25W 81.4 81.5 81 1h W 0.50W 84.5 84.3 84 1 W 1.00W 88.2 87.2 87 2W 2.00W 90.0 90.1 91 70 VRMS 14W 0.25W 81.5 81.9 81 ½W 0.50W 1 84.1 84.9 84 1 W 1.10W 87.9 87.9 87 2 W 2.30W 1 90.8 90.8 91 Standard Hz models (dBA1 at 3.05 m (10 ft.l 25 VRMS 14W 0.25W 81 ½W 0.50W 84 1W 1.00W 87 2W 2.00W 90 70 VRMS 14W 0.25W 81 ½W 0.50W 84 1W 1.00W 1 87 2W 2.00W 91 Current Draw Standard cd outout models Operating current, RMS (A) VDC 0.109 0.151 0.281 0.318 VFWR 0.131 0.194 0.379 0.437 Ught output (cd) Clear Lens 15 30 75 95 Amber Lens 13 26 65 82 Hiah cd outout models Operating current, RMS (A) VDC 0.330 0.392 0.502 0.565 VFWR 0.432 0.518 0.643 0.693 Ught output (cd) Clear Lens 95 115 150 177 Amber Lens 82 100 130 155 VDC = Volts direct current, regulated and filtered VPINF1 = Volts full wave rectified Operating currents shown above were measured at 16 VDC and 16 VFWR. "Sound level output notes: dBA " Decibels, A-weighted. UL1480: Sound level output at 10 it (3.05 m) measured in a reverberant mom using 400 to 4,000 Hz band limited pink noise. ULC-5541: Meets or exceeds 85dBA in an anechoic chamber at 10 ft (3.05 m) on at least one setting per code. Directional characteristics: Within 6 dB of on-axis sound level when measured 90° off-axis(horizontal). See "15" or "30° or note I "D" "C" RMS RMS 16Vdc 109 151 16Vfwr 131 194 Current Draw Notes UL Nameplate (high cd output Rating models) Ught output switch settings for UL 1971 listed models are selectable by numeric candela or "B""95" or "A" "95" or "115° or 1115011 or 1117711 or value. ECS/MNS appliances are selectable by "C" "Be RMS 502 643 "A" RMS 565 693 A, B, C, or D designations. Current values are shown in mA. RMS I RMS RMS RMS 392 518 281 318 330 379 •i 437 432 Typical Current See 1115" or note 1 "D" RMS "30" or "C" 5!or 'B" "95" or "A" RMS RMS RMS 16Vdc 94 140 273 325 20Vdc 74 108 205 244 29a 63 90 Inv 194 33Vdc 48 70 124 139 16Vfwr 126 187 368 403 20Vfwr 108 156 281 333 24Vfwr 97 139 240 270 33Vfwr 89 119 197 214 Typical rCurrent 95 cd w 115 cd _iii 150 Cd - 177 cd RMS RMS RMS RMS 333 392 499 551 259 303 378 429 212 245 306 342 155 180 211 236 484 570 673 724 380 438 537 604 318 361 434 484 245 269 308 338 Page 3of6 DATA SHEET E850010641 Not to be used for installation purposes. Issue 1 Wiring Field wiring terminals accommodate #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wiring. Input voltage matching the voltage rating of the speaker (25 or 70 Vrms) + u To listed To next fire alarm appliance, I I control end-of-line return to or panel control II.uI I I I equipment III II Specifications Housing Textured UV stabilized, color impregnated engineered plastic. Exceeds 94V-0 UL flammability rating. Red and white models available. Mounting Flush mount to North Amencan 4-inch square electrical box, 2-1/8 (54 mm) inches deep, or 960A-4RF round flush box. No extension ring required. Suitable for indoor wall or ceiling applications. Wire connections Screw terminals: polarized inputs for speaker, #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wire size. Operating environment Indoor only: 32-120° F (0-49° C) ambient temperature; 0-93% relative humidity. Agency listings and approvals, GC Models Meets ULC-S541, year 2004 UL requirements for standards UL1 638 and UL1 971. Complies with UL1 480 Fifth Edition. UL/ULC File Number: S2813. FM, MEA, CSFM approved. CSFM File Number: 7320-1657: 0211/0285. Speaker-strobes comply with ADA Code of Federal Regulation Chapter 28 Part 36 Final Rule. Agency listings and approvals, Low Frequency GCHF Models UL 464 Listed for low frequency signaling applications. Meets ULC-S541, year 2004 UL requirements for standards UL1 638 and UL1 971. Complies with UL1 480 Fifth Edition. FM, MEA, CSFM pending. Speaker-strobes comply with ADA Code of Federal Regulation Chapter 28 Part 36 Final Rule. Supervisory voltage 30 V max. Speaker Operating Voltage 25 Vrms or 70 Vrms Speaker response 400 to 4,000 Hz Output See table on previous page. Strobe Light output Field selectable. See table on previous page. Operating current See table on previous page. Strobe output rating UL 1971, UL 1638, ULC S526: selectable 15/30/75/95 Cd (VM models) and 95/115/150/177 cd IMH models) Strobe operating voltage 16 to 33 VDC (24 VDC nominal) or 16 to 33 VFWR (24 VFWR nominal) Strobe flash rate One flash per second, default. Temporal setting (private mode only): synchronized to temporal output of Genesis audible signals on same circuit. Synchronization Meets or exceeds UL 1971 requirements. Maximum allowed resistance between any two devices is 20 Ohms. Refer to specifications for the synchronization control module, this strobe, and the control panel to determine allowed wire resistance. Synchronization Sources SIGA-CC1S, SIGA-MCC1S, SlGA-CC2A, SIGA-MCC2A, G1M-RM, BPS6A, BPS10A, APS6A, APS10A, 0 Series, Fireshield Plus 3, 5 and 10 zone. Lens Optical grade polycarbonate. Page 4 of 6 DATA SHEET E85001-0641 Not to be used for installation purposes. Issue I Ordering Information High Fidel, Housing Text StroI Speaker Shipping:, Model (520 Hz capable) Color Marking Output Voltage Weight Life safety Aooliances GCHFRF-S2VMC I Red FIRE Selectable 15, 30, 75, or 95 cd White 25 Volt (Selectable ¼, ½, 1, or 2 watt) 1.62 lb. (0.73 kg.) GCHFWF-S2VMC I White GCF-S2VM GC-S2VM None GCHFRN-S2VMC I Red GCHFWN-S2VMC I GCHFRF-S2VMCH / Red FIRE Selectable 95, 115,150, 177 GCHFWF-S2VMCH I White GCF-S2VMH GCHFRN-S2VMCH I Red None GCHFWN-S2VMCH I White GC-S2VMH GCHFRF-S2 'I. Red FIRE White Speaker only models GCFR-52 GCHFWF-52 I GCHFRN-52 I Red None GCHFWN-52 / White GC-S2 GCWN-52 GCHFRF-S7VMC I Red FIRE 15, 30, 75, or 95 cd 70 V (Selectable 1/4.1/2, 1, or 2 watt) GG9F-WP-S7VIVIG,b I White GCF-S7VM GCHFRN-S7VMC I Red None GCHFWN-S7VMC GCHFRF-S7VMCH I Red ARE 95,115,150,177 GCHFWF-S7VMCH I White GCF-S7VMH GCHFRN-S7VMCH I Red None GCHFWN-S7VMCH I GC-S7VM WhiteH GCHFRF-S7 I Red FIRE Speaker only models GCFR-57 Red GCHFWF-S7 I White GCF-57 GCHFRN-57 I Red None GCWN-S7 GCHFWN-S7 I White GC-57 Page 5of6 DATA SHEET E850010641 Not to be used for installation purposes. Issue 1 L LIFE SAFETY & INCIDENT MANAGEMENT Contact us... Email: edwards.fire@fs.utc.com Web: Edwards-flre.com EDWARDS is a UTC brand. 1016 Corporate Park Drive Mebane, NC 27302 © 2016 United Technologies Corporation. All rights reserved. Ordering Information Model - Hih Text Lens Strobe Speaker Shipping Fidelity Marking Color Output Voltage I Weight Mass rouncation Appliances, wnite nousings GCHFWA-S2VMA I ALERT Amber None 13, 26, 65, or 82 cd 25 Volt (Selectable 14, ½, 1, or 2 watt) 1.62 lb. (0.73 kg.) GCWA-S2VMA GCHFWN-S2VMA I GCWN-S2VMA GCWN-S2VMC Clear _____ 15, 30, 75, or 95 cd _________ GCHFWA-S2VMC I ALERT GCWA-S2VMC GCHFWA-S2VMHA V Amber None 82, 100, 130, or 155 cd GCWA-S2VMHA GCHFWN-S2VMHA V.' GCWN-S2VMHA GCWN-S2VMHC Clear 95,115,150, or 177 cd GCHFWA-S2VMCH I ALERT GCWA-S2VMHC GCHFWA-S2 Speaker only models GCWA-S2 GCHFWA-S7VMA 1 ALERT Amber None 13, 26, 65, or 82 cd 70 V (Selectable 14, ½, 1, or 2 watt) GCWA-S7VMA GCHFWN-S7VMA ./ GCWN-S7VMA GCWN-S7VMC Clear ____ 15, 30, 75, or 95 cd ________ GCHRNA-S7VMC I ALERT GCWA-S7VMC GCHFWA-S7VMAH ,,, _____ Amber None _________ 82, 100, 130, or 155 cd GCWA-S7VMHA GCHFWN-S7VMAH I GCWN-S7VMHA GCWN-S7VMHC Clear 95, 115,150, or 177 cd GCHFWA-S7VMCH I ALERT GCWA-S7VMHC GCHFWA-S7 Speaker only models GCWA-57 Accessories Page 6 of 6 DATA SKEET E85001-0641 Not to be used for installation purposes. Issue 1 STATE FIRE MARSHAL LISTING SHEETS CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION W. OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. Page 1 of I CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models GC-VM, VM, GCFR-VM, GC-VMH, GCF-VMH, GCWAVMC*, GCWNVMC*, GCWAVMHC* and GCWNVMHC* multiple candela synchronizable strobe lights. The lights are only considered synchronized when used in conjunction with listed Model GIM-RM (CSFM Listing No. 7300-1657:201) sync module, which may employ Model SIGA-CC1S (CSFM Listing No. 7300-1657:121) Auto Sync Output Module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 16-33 VdcNfwr GC candela: 15cd, 30cd, 75cd, or 95cd H candela: 95cd, 115cd, 150cd, 177cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. For indoor use only, mounted on a wall or a ceiling. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as strobe lights for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7125-1591:219 7-29-10 ma 0 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed Mop - the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILL.O, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL LISTING SERVICE FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM (9 LISTING No. 320L1657...0324 Page 1 of 2 CATEGORY: 7320 - SPEAKERS LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models GCHFWA-52, GCHFWA-57, GCHFRF-S2, GCHFRF-S7, GCHFWF-S2, GCHFWF-S7, GCHFRN-52, GCHFRN-57, GCHFWN-S2 and GCHFWN-57 Speakers. Models GCHFRF-S2VMC, GCHFRF-S7VMC, GCHFRN-S2VMC, GCHFRN-S7VMC, GCHFWA-S2VMC, GCHFWA-S7VMC, GCHFWF-S2VMC, 3€HRWES7VMC1 GCHFWN-S2VMC and GCHFWN-S7VMC Speaker/Strobes. Models GCHFRF-S2VMCH, GCHFRF-S7VMCH, GCHFRN-S2VMCH, GCHFRN-S7VMCH, GCHFWA-S2VMCH, GCHFWA-S7VMCH, GCHFWF-S2VMCH, GCHFWF-S7VMCH, GCHFWN-S2VMCH and GCHFWN-S7VMCH Speaker/Strobes. Models GCHFWA-S2VMA, GCHFWA-S7VMA, GCHFWN-S2VMA and GCHFWN-S7VMA Speaker/Strobes. Models GCHFWA-S2VMAH, GCHFWA-S7VMAH, GCHFWN-S2VMAH and GCHFWN-S7VMAH Speaker/Strobes. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 25 Vrms or 70 Vrms 1/4W, 1/2W, 1W, or 2W Normal candela, clear lens: 15/30/75/95 cd Normal candela, amber lens: 13/26/65/82 cd High candela, clear lens: 95/115/150/177 cd High candela, amber lens: 82/100/130/155 cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name model number, electrical/candela rating and UL label. 07-21-15 gt ,,, This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7320-1657:0324 Page 2 of 2 APPROVAL: Listed as speakers and speaker/strobes for use with separately listed compatible fire alarm control unit. Clear lens models (suffix ending in C or CH) are suitable for the hearing impaired. The lights are only considered synchronized when used in conjunction with Model GIM-RM sync module (CSFM No. 7300-1657:0201) or Model SIGA-CCIS auto-sync output module (CSFM No. 7300-1657:0121). For indoor ceiling mounted use only. If the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation signal (for total evacuation) in accordance with NFPA 72, 2010 Edition is required, the appliance must be used with a fire alarm control unit that can generate the temporal pattern signal. Refer to listee's Installation Instruction Manual for details. If the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation signal (for total evacuation) is required for sleeping areas in accordance with NFPA 72, 2010 Edition is required, the appliance must be used with a fire alarm control unit that can generate the low frequency signal. Refer to listee's Installation Instruction Manual for details. 07-21-15 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division