HomeMy WebLinkAbout1546 BALBOA CR; ; FPC2017-0255PERMIT REPORT (ity of Carlsbad Print Date: 09/07/2023 Job Address: 1546 BALBOA CR, CARLSBAD, CA Permit Type: FIRE-Construction Commercial Parcel #: 2111310300 Valuation: $317,758.00 Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Work Class: Fire Alarm Track #: Lot #: Project #: Plan #: Construction Type: Orig. ; Plan Check #: Plan Check U: Permit No: FPC2017-0255 Status: Closed - Finaled Applied: 08/28/2017 Issued: 11/14/2017 Finaled Close Out: 03/19/2021 Final Inspection: INSPECTOR: Fieri, Dominic Project Title: Description: GRAND PACIFIC RESORT (MAINTENANCE BUILDING) -SPRINKLER MONITORING Applicant: FPContractor: BERGELECTRIC CORPORATION BERGELECTRIC CORP DONALD CIFUENTES 3182 LIONSHEAD AVE 955 BORRA PL CARLSBAD, CA 92010-4701 ESCONDIDO, CA 92029-2011 (760) 638-2374 (760) 746-1003 FEE AMOUNT FIRE Sprinkler Monitoring $371.00 Total Fees: $371.00 Total Payments To Date: $371.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov bBergelectric NATIONAL TECHNOLOGY SYSTEMS Submittal No. FA-001 Grand Pacific Resorts - Distribution Building Grand Pacific Drive Carlsbad, CA 920008 Bergelectric WO #: 114440 Addressable Sprinkler Monitoring System August 22, 2017 ELECTRICAL SUBCONTRACTOR Bergelectric Corporation 650 Opper Street Escondido, CA 92029 GENERAL CONTRACTOR ARCHITECT ENGINEER FPC2017-0255 1546 BALBOA CR For Review and Approval Stamping 650 Opper Street, Escondido, CA 92029- Tel (760) 746.1003 Fax (760) 741.0918 - License No. CI 0-85046 bBergelectric NATIONAL TECHNOLOGY SYSTEMS Submittal No. FA-001 Grand Pacific Resorts. Distribution Building Grand Pacific Drive Carlsbad, CA 920008 Bergelectric WO #: 114440 LIST OF REQUIRED SUBMITTALS Addressable Sprinkler Monitoring System Section Para. No. Item Description Submitted Herein Submitted Previously Future Submittal Sprinkler Monitoring Control Panel X Intelligent Initiating Devices X Intelligent I/O and Control Devices X Operation and Maintenance Manual - FACP X Testing Documents X NFPA 72 Record of Completion Forms X As-built Drawings X Product Data = P. Data Shop Drawings = Dwgs. Test Reports = T. Rpts. DNA = Does not apply to this project bBergele'ctric NATIONAL TECHNOLOGY SYSTEMS Submittal No. FA-001 Grand Pacific Resorts - Distribution Building Grand Pacific Drive Carlsbad, CA 920008 Bergelectric WO #: 114440 TABLE OF CONTENTS Addressable Sprinkler Monitoring System Section Item Description TAB # Sprinkler Monitoring Control Panel I Intelligent Initiating Devices 2 Intelligent I/O and Control Devices 3 Operation and Maintenance Manual - FACP 4 Testing Documents 5 NFPA 72 Record of Completion Forms 6 As-built Drawings 7 NAME OF SUBCONTRACTOR: Bergelectric Corporation AUTHORIZED SIGNATURE: Donald Cifuentes TITLE OR POSITION: Project Manager DATE: 8/22/2017 bBergelectric NATIONAL TECHNOLOGY SYSTEMS Submittal No. FA-001 Grand Pacific Resorts - Distribution Building Grand Pacific Drive Carlsbad, CA 920008 Bergelectric WO #: 114440 TAB# I Addressable Sprinkler Monitoring System Sprinkler Monitoring Control Panel EDWARDS Catalog 10, Small Building Fire alarm Solutions United Technologies LIFE SAFETY INCIDENT MANAGEMENT Intelligent Fire Alarm Systems 1064, 101000 FDNY COA 6227 0 7165-1657: 0244 S3000 Overview EDWARDS brand intelligent life safety systems offer the power of high-end intelligent processing in configurations that deliver uncomplicated solutions for small to mid-sized applications. With intelligent detection, electronic addressing, automatic device mapping, optional Ethernet® connectivity, and a full line of easily- configured option cards and modules, these flexible systems offer versatility that benefits building owners and contractors alike. The 1064 provides one Class A or Class B intelligent device loop that supports up to 64 device addresses, and two Class B Notifi- cation Appliance Circuits (NACs). Optional Class A device wiring is available with the use of a module. The 101000 provides one Class A or Class B intelligent device loop that supports up to 250 device addresses. Loop controller modules may be added in combination to expand total system capacity in 250-point increments to up to 1,000 device addresses. The iOl 000 panel includes four NACs that may be wired for either Class A or Class B operation. The RZI16-2 module adds even more capacity to iO installations by adding up to 16 conventional device circuits and two additional notification appliance circuits. This makes them an ideal retrofit solution that can accommodate new intelligent detectors, as well as existing conventional devices. 10 Series supports a wide range of high-end features, including: Signature Series intelligent modules, detectors, and bases A-Series remote annunciators SIGA-AEL Releasing Modules Fully integrated CO detection using Signature Series detec- tors with or without audible signaling Features Auto-programming speeds installation time Supports Signature Series intelligent modules and detectors Combines the Signature intelligent releasing module with Signature multisensor detectors for reliable fire suppression Form C contacts for alarm and trouble, Form A for supervisory Electronic addressing with automatic device mapping Optional Ethernet port for diagnostics, programming and a variety of system reports Two programmable switches with LEDs and custom labeling Supports Genesis horn silence over two wires, and UL 1971-compliant strobe synchronization Class B or Class A wiring Ground fault detection by module Supports up to eight serial annunciators, (LCD, LED-only, and graphic interface) Can use existing wiring for most retrofit applications Upload/download remotely or locally Two-level maintenance alert reporting Pre-alarm and alarm verification by point Adjustable detector sensitivity 4 x 20 character backlit LCD display Optional earthquake hardening: seismic Importance Factor 1.5 Standalone operation Transmission test frequency by hour Page lof8 DATA SHEET E850010135 Not to be used for installation purposes. Issue 1.1 Application EDWARDS i0 Series life safety systems are powerful intelligent solu- tions for small to mid-sized buildings. Advanced intelligent technol- ogy delivers the benefits of flexible system installation, while clean and easy-to-operate user interfaces make panel operation and system maintenance quick and intuitive. The smart choice Signature Series electronic addressing eliminates the tedium of setting dipswitches, and automatic device mapping ensures that each device resides on the system at its correct location. Mean- while, innovative programming allows the designer to customize the system to precisely suit the needs of the building owner. Reliability you can count on The inherent fault-tolerant characteristics of Analog/Addressable Technology boosts the reliability of EDWARDS fire alarm systems. When combined with 10 Series smoke and heat detectors, these systems deliver a level of dependability not previously available for small to mid-sized applications. All EDWARDS systems are built to exacting reliability benchmarks and meet international standards for quality, in addition to agency listings for dependability. Clear-cut remote annunciation Remote annunciation is a strong suit of the 10 Series fire alarm systems. Up to eight annunciators can be installed on a single system. Compatible annunciators include a range of LED and LCD models that provide zone or point annunciation, as well as com- mon control capabilities. i0 control panels also supports graphic annunciation with optional RA Graphic Annunciator interface mod- ules. Each interface provides common control and 32 LEDs. Programming and remote diagnostics EDWARDS iO Series life safety systems are simple to set up, yet offer advanced programming features that put these small building panels into a class of their own. The auto programming feature quickly gets the panel operational using factory default settings. Basic zone and point settings can be programmed through the front panel interface, so the system is up and running in no time. For more advanced system configuration and correlation groups programming, 10 Series systems interface to a PC running com- patible iO-CU software. This option offers full system configuration in the familiar Windows® operating environment. Connection is made to a laptop through the panel's optional RS-232 communi- cations port, which can also be used to connect a system printer. Among the many innovative features of iO Series control panels is the optional network card. This module provides a standard 10/100 Base T Ethernet® network connection that permits access to the control panel from any remote location with the correct communications protocols. The connection can be used to download to the panel from the iO-CU, or upload and view system reports using the iO-CU. Available system reports include: Correlation groups Device details Device maintenance History Internal status System configuration System status Walk test Dialer CO runtime Flexibility built right in Two fully-programmable front panel switch/LED combinations pro- vide an added measure of flexibility. Their slide-in labels take the mystery out of custom applications, and present a clean finished appearance. Perfect for retrofits EDWARDS i0 Series control panels are particularly well-suited to retrofit applications. All connections are made over standard wiring - no shielded cable required. This means that in most situations existing wiring can be used to upgrade a legacy control panel to i0 technology without the expense or disruption of rewiring the en- tire building. i0 control panels also support the ingenious RZ116-2 Zone Module, which adds up to 16 conventional circuits and two NACs. This combination easily accommodates new intelligent detection alongside existing conventional circuits, making it an superior solution in the retrofit market. Signals with a difference i0 system NACs are configurable to fully support the advanced signaling technology of EDWARDS Genesis and Enhanced Integ- rity notification appliances. These devices offer precision synchro- nization of strobes to UL 1971 standards. For Genesis devices, enabling this feature allows horns to be silenced while strobes on the same two-wire circuit continue to flash until the panel is reset. A complete line of accessories i0 Series life safety systems are supported by a complete line of analog/addressable detectors, modules and related equipment. Consult the Ordering Information section for details. Dimensions (21 (3) (4) 10 r To 0 o I IP I 0 D4 01 0 Surface Mounting Holes (3) Backbox with Door Attached Semi-flush mounting Holes (4) Backbox with door and trim kit attached. Panel dimensions, in (cm) Model DI* I (32 (33 I D4 I D5' I D6 I D7 I (38 I 01000 28.0 3.85 9.0 I 22.0 I 15.75 I 10.25 I 4.4 I 28.2 I 2.7 (71.1) I (9.8) i(22.8) I (55.8) I (40.0) I (26.0) I (11.1) I (71.6) I (6.8) 21.5 I 3.85 I I 15.5 I 14.25 I 10.25 I 21.7 I 2.7 (54.6) () (19.0) (39.4) (36.2) (26.0) (11.4) () (6.8) 'Add 1-1/2 in. (3.81 cm) to Dl and D5 dimensions for him kit. The trim kit provides 0.75 inches (1.9 cm) of turn to the top, bottom, and sides of the backbox. Page 2of8 DATA SHEET E850010135 Not to be used for installation purposes. Issue 1.1 Ethernet (SA-ETH) DACT/Dialer (SA-DACT) RS-232 (SA-232) Relays: Two Form C, one Form A System Layout 101000 Any combination of two single- or dual Signature loop modules -R-fl :fl i ri ne expansion slot) : 10-SDC2 Expander, Loop 1 of 2:250 points (one expansion slot) iO-SDC1 Expander Loop: 250 points (one expansion slot) iQ-SDC2 Expander, Loop 2 of 2:250 points ,Upto 20,000 feet of wiring per loop Ethernet (SA-ETH) DACT/Diaier (SA-DACT) RS-232 (SA-232) Relays: Two Form C, one Form A Each 101000 panel has room for up to two Signature loop ôontöl- ler modules in any combination of single or dual 250-device loops. i01000 loops support 125 detectors and 125 modules. 1064 IIIL_s Loop supports up to 64 intelligent devices of any type. Up to 20,000 feet of wiring. 1 I Each i064 panel ships with one Signature loop controller that sup- ports 64 devices of any type. This panel's device capacity cannot be expanded. Up to eight remote annunciators Sixteen Conventional lDCs, two additional NACs with RZ116-2 module p .. I iEffi LI _I- sil • Lit i • f."IP(. - I 1 Tthristorrner Page 3of8 DATA SHEET E850010135 Not to be used for installation purposes. Issue 1.1 Class A Wring to1 Wiring & Configuration Signature device loop The system provides one Signature device loop circuit with a total capacity of 125 detectors and 125 module addresses. The loop circuit is supervised for opens, shorts, and grounds. Circuit 1101000 1064 specifications Device loops One Class B or A One Class B or A loop, loop, supporting 125 supporting 64 devices of detectors and 125 any kind. modules. Expandable to four loops. Communication Maximum 20 V peak-to-peak line voltage Circuit current 0.5 A max Circuit 66C) total, 0.5 hF, max impedance Isolators 64 maximum Signal Supported on a system-wide basis (all device loops) Synchronization when using a SIGA-CC1 S or SlGA-MCC1 S module and Genesis or Enhanced Integrity notification ap- pliances. Class a wiring SLCA DateLine SLCB Loop Loop Loop card device device Class A wiring ~dteA_d=ev1cpe Loop card Data Line Notification appliance circuits (TB2) iOl 000 control panels come equipped with four notification ap- pliance circuits. i064 control panels come with two NACs. Each circuit can be individually configured for continuous, temporal, synchronized, and coded output. Specifications i01000 1064 Circuit Type 4 Class B or 2 Class A 2 Class B or 2 Class A with SA-CLA module Voltage 24 VRNR Current 6.0 A total, 2.5 A max. 3.75 A total, 2.5 A max. per circuit at 120/230 per circuit at 120/230 VAC 60 Hz. VAC 60 Hz. 5.0 A total, 2.5 A max. 3.0 A total, 2.5 A max. per circuit at 230 VAC per circuit at 230 VAC 50 Hz. 1 50 Hz. Impedance 260 total, 0.35 pF max EOLR 15K0,1hW Synchronization Supported system-wide Class awlring nv.mml J..IIIWA un 'i 4M -,--- Marking indicates output signal polarity when the circuit is active. Polarity reverses when the circuit Is not active. Wire notification appliances accordingly. Notification appliance polarity shown inactive state. Auxiliary & smoke power outputs (TB3) The control panel provides two auxiliary power outputs that can be used for powering ancillary equipment such as remote annunciators and two Wire smoke detectors. Aux 2 can be software selected to operate continuously. The circuit is supervised for shorts and grounds. I Circuit specifications Circuit voltage 21.9 to 28.3 V range Resettable circuit 24 VDC nominal at 500 mA (Aux power 2) Continuous circuit 24 VDC nominal at 500 mA. (Aux power 1) Use this circuit for powering two-wire smoke detectors. Note: Any current above 0.5 amp connected to both Aux 1 and 2 Will reduce the total available NAG power by that amount. (1) Trouble Alarm, trouble, and supervisory relay (T133) (2) Supervisory The trouble relay is normally-open, held closed, (3) Alarm and opens on any trouble event or when the panel is de-energized. The supervisory relay is (4) Smoke/Aux normally-open, and closes on any supervisory event. The alarm relay changes over on any alarm event. Relay specifications - AIarm Trouble Supervisory Type Form C Form A Voltage 24 VDC at 1 A resistive 24 VDC at 1 A resistive Relay circuits can only be connected to power-limited sources. Annunciator loop (TB4) The control panel provides a connection for up to eight serially driven and supervised remote annunciators. Circuit specifications Device loops Class B (Style 'Y) or Class A (Style Z) Circuit voltage 2.55 V Circuit current 30 mA max Circuit Up to 8 annunciators or 4000 feet impedance Class B Class A Channel Channel Channel Channel Annunciator Annunciator )CHI(+)IN CHI (-)IN CHI (-) IN CH2(+)IN I ' [_4cH2(+)lN CH 2 (-) IN CH2 (-) IN Page 4 of 8 DATA SHEET E85001-0135 Not to be used for installation purposes. Issue 1.1 Option Cards EDWARDS 10 Series panels are supported by a complete line of modules and related equipment that enhance performance and extend system capabilities. Option cards plug directly into the control panel main circuit board or are connected to it with a ribbon cable. After installation, terminals remain accessible. The cabinet provides ample room for wire routing, keeping wiring neat at all times. Single and Dual Loop Controller Cards The iO-SDC1 is a single loop controller card that can be used with the i064 as a replacement for the standard 64-point loop, or with the 101000 as a 250-point expansion module. The iO-SDC2 is a 500-point dual loop controller card for the 101000 that provides two SLC circuits, each with 125 detector addresses and 125 module addresses. Specifications 10-SDC1 iO-SDC2 - Device Addresses i01000: one loop, 250 device addresses i064: 64 addresses 01000: two loops, 500 device addresses Wiring Class B or Class A Operating Voltage 24 VDC Operating Current (fully loaded loop) Standby: 55 mA Alarm: 80 mA Standby: 45 mA Alarm: 70 mA Note: These ratings do not include the use of two-wire smoke modules. Communication Une Max. 20.6 V peak-to-peak Voltage Terminal Rating 12 to 18 AWG (0.75 to 2.5 mm2) Circuit Current 0.5 A max. Max total loop 660 resistance Max total loop 0.5 i.iF capacitance Isolators 64 isolators maximum per loop (total both isolator bases and modules) Ground Fault 0 to 51<0 Impedance Operating 32 to 120°F (0 to 49°C) Environment 0 to 93% noncondensing at 90°F (32°C) SA-ETH Ethernet Interlace Card SA-ETH wiring To network The SA-ETH card provides a standard 10/100 Base T Ether- net network connection for Network cable connection connecting to an intranet, a local network, or the Internet. The I card can be used to download 1 1 1 I configuration programming from I13L__J I the i0-CU to the panel. I The Ethernet card is installed on : the plastic assembly and con- Ethernet card nects to the main circuit board via a ribbon cable. SA-ETH specifications Ethernet 10/100 Base T Operating environment Temperature 32 to 120°F (0 to 49°C) Humidity 0 to 93% RH, noncondensing at 90°F (32°C) Page 5 of 8 RZII6-2 Remote Zone Interface Module I The RZI16-2 Addressable Remote Zone Interface Module is an addressable device that provides connections for sixteen Class B Initiating Device Circuits and two Class B Supervised Output Circuits. The inputs and outputs can be configured individually for several device types. It requires 18 consecutive addresses on the Signaling Une Circuit (SLC). Addresses are assigned electronically. There are no address switches to set. The RZI16-2 incorporates two 8-segment DIP switches that are used to select the Alarm or Supervisory default device type for each of the 16 IDC circuits. The module also includes one 4-seg- ment DIP switch used to select the default Relay or NAG output device type. Device types other than the default are accomplished through programming. RZII6-2 Specifications Voltage 24V/Aux nominal: 24 VDC Supervisory current: 250 mA at 24 VDC nominal Alarm Current 1000 mA 24V/Aux minimum: 18.4 VDC 24V/Aux maximum: 26.4 VDC NAC1, NAC2 nominal: 24 VDC Current Standby current for 4.7 k EOL (U.S.) 4.8 mA/ circuit Standby current for 3.9 k EOL (Canada) 5.7 mA/ circuit Alarm current at nominal voltage 31.1 mA/ circuit Relay outputs Quantity 2 Type Rating (pilot duty) Programmable 24 VDC at 2.5 A Input circuit wiring 25 () per wire resistance Initiating device circuits Quantity 16 EOL resistor 4.7 k() (U.S.); 3.9 ko) Canada Zone voltage 22.78 V for 4.7 1<0 (U.S.) 22.08 V for 3.9 kO (Canada) Alarm current 31.1 mA/ channel at nominal voltage Alarm impedance range <6801) Trouble impedance range >5.55 kO Supervised output circuits EOL resistor 15 kO Quantity 2 Short circuit detection <2.61<0 Open circuit detection >61.9 kO Contact ratings 24 VDC at 2.5 A (5 A for two NACs) Compatible cabinets MFC(A), 101000, APS DATA SHEET E85001 -0135 Not to be used for installation purposes. Issue 1.1 (3) (4) (5) LED 1 LED 2 LED Expander 1 LED Expander 2 Alarm/non-alarm and trouble zone LEDs SA-DACT Dialer The SA-DACT provides communications between the control panel and the central station over a telephone line system. It transmits system status changes (events) to a compatible digital alarm communicator receiver over the public switched telephone network. The dialer is capable of single, dual, or split reporting of events to two different account and telephone numbers. The modem feature of the SA-DACT can also be used for uploading and downloading panel configuration, history, and current status to a PC running the iO-CU. SA-DACT Phone line 2 wiring [line1 To wall rl phone jack Phone The dialer phone lines connect to connectors on the dialer's main circuit board. Phone line 1 connects to connector J4 and phone line 2 connects to connector Ji. The SA-DACT queues mes- sages and transmits them based on priority (alarm, supervisory, trouble, and monitor). Activations are transmitted before restora- tions. The SA-DACT is installed on the plastic assembly and connects to the main circuit board via a ribbon cable. SA-DACT specifications Phone line type One or two loop-start lines on a public, switched network Phone line connector RJ-31/38X (C31/38)) Communication formats Contact ID (SIA DC-05) Operating environment Temperature 32 to 120°F (0 to 49°C) Humidity 0 to 93% RH, noncondensing at 90°F (32°C) Compatible DACRs Receiver Models Formats Ademco 685 Contact ID FBll 0P220 Contact ID Osborne-Hoffman OH 2000 Contact ID Bosch D6600 Contact ID Silent Knight 9800 Contact ID Sur-Gard SG-MLR1, MLR2 Contact ID The SA-232 card provides an RS-232 in- GND (black wow) SA-232 RS-232 interface SA-232 wiring terface with iO panels. It can be used for to print system events. The card also connecting a printer to the control panel fl: RXD (red wire) TXD (white wire) can be used for connecting a computer 0 6L to download a configuration program from the 10-CU to the control panel. The RS-232 card is installed on the plas- tic assembly and connects to the main circuit board via a ribbon cable. SA-232 spec flion Operating voltage Standard ElA-232 Terminal rating 12 toll AWG (0.75 to 2.5 sq mm) Operating environment Temperature 32 to 120°F (0 to 49°C) Humidity 0 to 93% RH, noncondensing at 90°F (32°C) SA-CLA Class A Module (1064 only) The SA-CLA card provides Class A capability for NAC wiring. Its terminal block provides the wiring connection for NAC return wiring. The card is required for annunciator Class A wiring even though this wiring does not return to the SA-CLA card. The SA- CIA is compatible with i064 control panels only. iOl 000 panels are Class A Ready. The SA-CLA is installed directly to the control panel circuit board using its plastic standoffs and plug connection. SA-CLA specifications Operating voltage 24 VFWR Operating current 3.75 A FWR total at 120/230 VAC 60 Hz 3.0 A FWR total at 230 VAC 50 Hz 2.5 A max per circuit Circuit impedance 26 ohms, 0.35uF Terminal rating 12 tol8 AWG (0.75 to 2.5 sq mm) Operating environment Temperature 32 to 120°F (0 to 49°C) Humidity 0 to 93% RH, noncondensing at 90°F (32°C) DI6L-iO LED Display Expander (iOl 000 only) The D16L-iO LED Display Expanders provide LED annunciation for up to 16 zones. It provides two LEDs for each zone. Two D1 6L-10 LED display expanders can be installed in each i01000 panel. Page 6 of 8 DATA SHEET E85001-0135 Not to be used for installation purposes. Issue 1.1 Specifications 064 iOl000 Device loops 1 loop Class B or Class A (Styles 4, 6, 7) supporting up, to : loop expandable to 4, Class A or B (Styles 4, 6, 7),: 64 device addresses (any combination of detectors and each loop supportingupto 250 device addresses (125 modules) detectors and 125 modules max.). Addresses 1 t 125 are Maximum T-taps: 63 for detectors and addresses 126 to 250 are for modules (each device can be on its own branch) Maximum 1-taps/loop: 124 Notification appliance 2 Class B (Style '1), Class A (Style 2) optional 4 Class B (Style or 2 Class A (Style Z) circuits 3.75 A FWR total at 120/230 VAC 60 Hz 6.0 A FWR total at 120/230 VAC 60 Hz 3.0 A FWR total at 230 VAC 50 Hz 5.0 A FWR total at 230 VAC 50 Hz 2.5 A FWR each max. per circuit 2.5 A FWR each max. per circuit Primary power 120 VAC, 60 Hz, 1.3 A max. 120 VAC, 60 Hz, 2.0 A max. 230 VAC, 50-60 Hz, 0.62 A max. 230 VAC, 50-60 Hz, 0.97 A max. Base panel current standby 155 mA 172 mA Base panel current alarm 204 mA 267 mA Input zones 16 max. 32 max. Remote annunciator 8 drops max., RS-485 Class B, Class A is optional 8 drops max., RS-485 Class A or B Data line length: 4,000 ft. (1,219 m) Data line length: 4,000 ft. (1,219 m) Operating voltage 24 VDC panel Auxiliary power output Aux power 1: 500 mA, 24 VDC circuit Aux power 2: 500 mA, 24 VDC (1 A possible if you reduce total available NAC power by 500 mA) Output: 28.3 to 21.9 VDC, special application Note: Fora list of compatible devices, see the 1064 and 01000 Series Compatibility List P/N 3102353EN) Loop circuit Maximum loop resistance: 66 C) Maximum loop capacitance: 0.5 pF Communication line voltage: Maximum 20.6 V peak-to-peak Operating current (fully loaded loop) Stand by: 55 mAI45 mA Alarm: 125 mW115 mA (not including two-wire smoke modules) Circuit current: 0.5 A max. Style 4, 6, and 7 wiring Max. resistance between isolators: Limited only by overall wire run lengths 64 isolators maximum per loop (total both isolator bases and modules) Batteries Type: Sealed load acid Voltage: 24 VDC Charging current: 2.47 A max. Amp hour capacity: 26 Ah Standby operation: 24 hour or 60 hour Placement: Up to two 10 Ah batteries will fit in the i064 control panel cabinet and two 18 Ah batteries will fit in the i01 000 control panel cabinet. If larger batteries are required, use an EDWARDS battery cabinet. SA-DACT dialer Phone line type: One or two loop-start lines on a public, switched network Phone line connector: RJ-31/38X (C31/38)Q Communication formats: Contact ID (SIA DC-05) Operating current Standby/Alarm: 41 mA Max.: 100 mA FCC registration number: GESAL01 BSADACT Industry Canada Registration number: 3944A-SADACT Ringer equivalence number: 0.1 B Ground fault impedance 0 to 5 ko) Alarm contact Form C N.O. 24 VDC at 1 A (resistive load) Trouble contact Form C 24 VDC at 1 A (resistive load) Supervisory contact Form A N.O. 24 VDC at 1 A (resistive load) Environmental Temperature: 0 to 49°C (32 to 120°F) Relative humidity: 0 to 93% noncondensing Terminal rating All terminals rated for 12 to 18 AWG (0.75 to 2.5 mm2) -- Page 7 of 8 DATA SHEET E85001-0135 Not to be used for installation purposes. Issue 1.1 Ordering Information 'ZIVVARDS iart bescription 101000 Fire Alarm Systems I01000G Four loop system with one 250-point loop installed. 110v, gray door. LIFE SAFETY & INCIDENT MANAGEMENT I01000G-2 Four loop system with one 250-point loop installed. 230v, gray door. 101000G-2-PG Four loop system with one 250-point loop installed. 230v, gray door, Portuguese. Contact us... 101 000G-2-SP Four loop system with one 250-point loop installed. 230v, gray door, Spanish. Email: edwards.fire@fs.utc.com 101 000G-CA Four loop system, one 250-point loop installed. 110v, gray door, LED strips, Canada. Web: Edwards-flre.com I01000GD Four loop system, one 250-point loop installed. 11 Ov, gray door, with dialer. 101000G-F Four loop system, one 250-point loop. 110v, gray door, LED strips, French Canada. 101 000G-PG Four loop system with one 250-point loop installed. 110v, gray door, Portuguese. EDWARDS is a UTC brand. 1016 Corporate Park Drive I01000G-SP Four loop system with one 250-point loop installed. 11 Ov, gray door, Spanish. Mebane, NC 27302 101000R Four loop system with one 250-point loop installed. 110v, red door. IrVinnno n C,,, ,. I, ")Of'I,, .,.l © 2016 United Technologies Corporation. iu i uuursu rour loop system, one ou-porni loop instaiiea. I I UV reo 000r, wirn uialer. All rights reserved. SA-TRlM2 101000 Rush mount trim, black 1064 Fire Alarm Systems 1064G One loop system with one 64-point loop installed. 11 0y, gray door. 106413-2 One loop system with one 84-point loop installed. 230v, gray door. 1064G-2-PG One loop system with one 64-point loop installed. 230v, gray door, Portuguese. 1064G-2-SP One loop system with one 64-point loop installed. 230v, gray door, Spanish. 1064GD One loop system, one 64-point loop installed. 11 Ov, gray door, with dialer. 1064GL One loop system, one 64-point loop installed. 11 Ov, gray door, English Canada. 1064GL-F One loop system, one 64-point loop installed. i1 0v gray door, French Canada. 1064G-PG One loop system with one 64-point loop installed. 110v, gray door, Portuguese. 1064G-SP One loop system with one 64-point loop installed. ilOv, gray door, Spanish. 1064R One loop system with one 64-point loop installed. 110v, red door. 1064R-2 One loop system with one 64-point loop installed. 230v, red door. 11064RD One loop system, one 64-point loop installed. 11 0v, red door, with dialer. SA-TRIM1 1064 Rush mount trim, black Ootion Cards 10-SDC1 Expansion module, one 250-device loop. 10-SDC2 Expansion module, two 250-device loops, 500 devices total. For 101000 only. RZ116-2 Remote Zone Interface Module. 16 Class B lDCs, 2 Class B Output. Includes bracket. SA-DACT Dual Une Dialer/Modem, supports Contact ID, mounts in cabinet on base plate. SA-232 RS-232 Serial Port for connection to printers & computers, mounts in cabinet. SA-ETH Ethernet Port, Slave, mounts in cabinet on base plate. SA-CLA Class A adapter module. Provides Class A capacity on NACs. Mounts in cabinet on main board. iO64 systems only. D16L-10-2 LED Annunciator module, 16 X 2-LED zones (4 programmable for sup). Mounts in cabinet to right of LCD display for zones 17-32. For 101000 only. D16L-10-1 LED Annunciator module, 16 X 2-LED zones (4 programmable for sup). Mounts in cabinet to left of LCD display for zones 1-16. For 101000 only, D813Y-10-2 Canada only: LED Annunciator module, two LEDs per zone, 16 zones (4 alarm only, 8 supervisory only, 4 alarm or supervisory). Mounts in cabinet. For 101000 only. DBRY-10-1 Canada only: LED Annunciator module, two LEDs per zone, 16 zones (4 alarm only 8 supervisory only, 4 alarm or supervisory). Mounts in cabinet. For iO1000 only. Accessories - - CTM City Tie Module. 2-gang. Connection to a local energy fire alarm box. X 14 X SIGA-REL Releasing Module PT-is System Printer BC-1 Battery Cabinet. 14.0" x 18.25' x 7.25". Holds two 12V24A batteries. BC-11 R Battery Cabinet - Red. 14.0" x 18.25' x 7.25". Holds two 1 2V24A batteries. BC-1 EQ Seismic hardening Kit for i0 series panels. Includes battery hardening for BC-1 enclosure and components to harden panel internal components. Programming Tools jO-CU 10 Series oonflauration and diaanostics utility Page 8 of 8 DATA SHEET E85001-0135 Not to be used for installation purposes. Issue 1.1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 9 LISTING No. 7165-1657:0244 Page 1 of 2 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Single and multi-loop analog addressable fire alarm control unit. Local, local with shunt, auxiliary, remote station, central station, releasing device. Power limited, non-coded, coded, shunt, reverse polarity, DACT, manual, automatic waterflow and sprinkler supervisory service. Models "EST" iO1000G,_iO1000G-2, 10I000GD, iO1000R, iOI000R-2, iOI000RD, i064G, i064-GD, 1064-R,064.I5) iO64G-2, i064R-2; i0500G, i0500GD, i0500R, i0500RD, i0500G-2, i0500R-2. Models "Vigilant/Kidde" VSI-G, VSI-GD, VSI-R, VSI-RD, VSI-G-2, VSI-R-2; VS2-G, VS2-GD, VS2-R, VS2-RD, VS2-G-2, VS2-R-2, vs4-G, vs4-G-2, vs4-GD, vs4-R, vs4_r-2, vs4-RD,. Models 'FireworXlKidde" FX-64G, FX-64GD, FX-64R, FX-64R0, FX64G-2, FX-64R-2, FX-254G, FX-254GD, FX-254R, FX-254RD, FX254G-2, FX-254R-2, FX-1 000, FXI 000D. Models "Edwards Signaling" E-FSA64G, E-FSA64GD, E-FSA64R, E-FSA64RD, E-FSA250G, E-FSA250GD, E-FSA250R, E-FSA250RD System Components: SA-DACT; Dialer SA-CLA; Class A Adapter SA-ETH; Ethernet Adapter SA-232; RS232 Module DI6L-iO, -VS, -Fa, D8RY-10-1, D8RY-iO-2, D8RY-VS, 16 Zone Front Panel LED XAL250, V-SLC, XALI27; SLC Loop Driver io-SDCI, V-SLC2-1, FX-SLCI Single SLC Card, 250pt lo-SDC2, V-SLC2-2, FX-SLC2 Dual SLC Card, *500pt *IDfl -S: System Printer *pT1..P: System Printer Parallel Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120/230 VAC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. *102416 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed fj\ the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-1657:0244 Page 2 of 2 MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as fire alarm control units for use with separately listed compatible initiating and indicating devices. *These control units meet the requirement of UL 864, 9th Edition Standard. *102416 dc it This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct . operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division TG-7FS LTE - A CELLULAR ALARM COM M U N I CATOR FOR LIE NETWORKS TE LG UAR D i COMMERCIAL FIRE PRODUCT FEATURES Certified for use on the AT&T LIE network for long, sunset-free installation. Meets UL 864 reuirernents for sole, primary or backup path communications. Minimizes false alarms by providing dual paths for self-tests. Falls back to 3G/4G if an LIE network is not available, for extended network coverage. The Telguard TG-7FS LIE-A is the ideal cellular alarm communications solution for commercial fire systems. The TG-7FS LTE-A transmits alarm signals from the fire panel over the digital cellular network to the designated monitoring station. Compliant with the 2013 Eclibon of NEPA 72, the TG-7FS LTE-A can serve as the sole conimunications path for the fire alarm system. It replaces all of the lancHnes currently dedicated to the master control unit, On average, cellular monitoring costs the end user significantly less than a dedicated landline. For each landline replaced with a TG-7FS LIE-A, the monthly communications bill decreases. By being able to signal failures to the central station within sixty minutes of an outage, the TG-7F8 LIE-A can be installeo as the sole path for commercial fire installations. For existing installations, all landlines can be swapped for a single TG-7FS LIE-A because of the new sixty minute supervision mode. The IC-7FS LIE-A can also be installed as a bachup path and upgraded to sole path at a later date. Telguard Portal Telguard makes adopting cellular easy with a secure Internet portal. The straightforward web interface allows security dealers and central stations to quickly and efficiently access Telguard based services 24/7 This advanced tool has multi-level user authorization and provides total account management of UL Listed Telguard cellular alarm communicators. Telguard Cellular Servce Telgua-d Cellular Service provides AT&T LTE network coverage for all Telguard units. TelgLard's Communication Center is UL compliant and provides seamless connectivity between the alarm panel, the Telguard farrrfly of products and the central statian. Telguard Technical Support provides a single point of contact for bath cellular service and Telguard product questions. Advanced Reliability Features the ability to utilize multiple cellular technologies to increase availability and reduce false alarms. Automatic self-tests with central station notification ensure the cellular system is operating. Available -elay output for tripping the alarm control panel when a trouble ccndition occurs. TG-7FS CELLULAR ALARM COMMUNICATOR LTE-A FOR LIE NETWORKS TE LG UAR D Power Transmit Power: 200 mW in all bands. - ! / Power Consumption: (I 60mA (Standby) 250mA (Transmission). Transformer: 12VAC, 800mA I UL listed plug-in. Telguard technology allows full data reporting for unlimited Radio Transceiver point-to-point signal details and maximum transmitting power for superior in-building penetration. Telguard products are easy to install, economical, and UL Listed. Accessories ACID 12, ACD 35, ACID .50, ACID 100: 12/35/50/100 feet of low loss, high performance cable, HGD-0: High gain directional antenna. EXD-0: External antenna. UL Listings Commercial Fire 864 Control units & accessooics for fire alarm systems Commercial Burglary 365 ' Police Station connected burglar alarm units and systems 1610 Central station burglar alarm unts: Line security servcies Residential 985 ' Householo lire warning s'jste "na 1023 • Household bulglal alarm systems ULC Listings 5545 Canadian household lire warning systems S304 Canadian commercial burglary alarm systems C0123 Canadian household burglary alarm systems tO: rc"t j'r -rt nrcduct spec If:t.on in L L.stIrl.,,'. .1 c'rn I& ~~l .::.. :m. .. G us LJ S i7 NFPA //1 1\ Connected LISTED a. - p INERU#TIOA1 LTE Bands: 2, 4 & 17. 3G Bands: 2 & S. Antenna: 9" dipole with 2dBi cir 12 ft of cable and universal mounting bracket. FCC part 15, 22, 24 and 68 compliat Physical Details TG-7FS LTE-A: 7.5" H x 11.5" W x 3.5" D. Shipping Weight: 81bs. Operating Environment: 0°C to +50°C up to 95% hurnicity (non-condensing). Standard Features Full data reporting. Automatic self-test (60 rnin & dly) Locking, red metal enclosure. Two programmable supervisory trip outputs. Alarm format support for SlA2, Contact ID, pulse (3x1, 4x2), modem Ile, & lila2 , DNIP. Telephone line monitor built-in, with Standard Line Security. Telguard, a Division of Telular Corporation• 3225 Cumberland Blvd SE • Suite 300' Atlanta, GA 30339 USA 800-229-2326, Option 5 • www.lelguard.com • Copyright 2017 lelular Corporation All Rights Reserved CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1402:0109 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: TELULAR CORP.3225 Cumberland Blvd, Suite 300, Atlanta, GA 30339 Contact: Raj Kosaraju (678) 264-2012 Fax (678) 264-2062 Email: rkosarajutelular.com DESIGN: Models *TG7L01 *TG7LA00I *TG7LAF0I and *TGKITLAI digital cellular radio alarm transmission system for fire/burglar alarm system control units. Models **TG7L4ft01 *TG7LA00I are household application. Model *TG7LAF0I and *TGKITLAI are for commercial application. Refer to listee's printed data sheet for additional detailed product description and operational considerations INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as digital cellular radio alarm transmission devices to provide a standalone transmission path (cellular) for a listed compatible fire and burglar alarm control unit. It may also provide a backup communication path when used in conjunction with a DACT. This product is to be connected to a listed control panel in accordance with the installation instructions provided by the manufacturer. NOTE: Burglary and other non-fire functions were not examined. * Revised 01-04-2017 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division ACE-11 I FIRE ALARM DOCUMENTS The FAD is the perfect fit to meet the demanding code requirements today. SAE's number one goal is to manufacture code compliant solutions and this product allows you to do just that. NFPA 72 2007 section 6.2.2.1 states, "A record of installed software and firmware version numbers shall be maintained at the location of the fire alarm control unit." This durable 16 gauge steel enclosure with a solid piano hinge and key lock will keep all of your code required documents in one safe place. With a 4GB USB flash drive it stores your fire alarm software safe and secure eliminating the occurrences of the soft- ware not being on site when technicians arrive to service the system. Along with your fire alarm soft- ware you can store your test & inspection docu- ments, service records, manuals & AS built drawings for the system. Using a standard USB B connector it allows you to plug in with any standard SB printer cable to upload or download information. The FOB is designed to hold critical manuals and documents with a durable steel retainer. It has designated hooks to organize key rings and hold important business cards for easy access and reference. Inside the cover it has a organized note table that allows for documentation for passwords and other critical system information. Standard Features: Installed with a 4 gig digital flash drive with USB B connector 2 Key ring hooks to hold system keys Business card holder for key contacts Overall Dimensions are 12" x 13" tall and 2 1h deep 16 gauge steel box and cover for security Durable powercoat baked on finish other colors available Standard 3h"cat 30 key lock other lock as- semblies available Solid stainless steel piano hinge Permanently screened white ink 1" high "Fire Alarm Documents" Legend sheet for passwords and system information X-PIRMIM: M.,11001 Made In\U.S.A. iso 9oo11 REGISTERED MPANY V Space Age Electronics, Inc. www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax Space Age Electronics, Inc. 2009 ED0549 LT10559 Rev.D 1/2 No Excuses, Just Solutions! SPACE AGE OW ELECTRONICS, INC. Specifications: The fire alarm documents box (FAD) shall be UL Listed, constructed of 18 gauge cold rolled steel. It shall have a red powder coat epoxy finish. The cover shall be permanently screened with 1" high lettering "FIRE ALARM DOCUMENTS" with white indelible ink. The access door shall be locked with a 3/4" barrel lock and the hinge shall be a solid width 12" stainless steel piano hinge. The enclosure will supply 4 mounting holes. Inside the enclosure will accommodate standard 8 1/2 x 11 manuals and loose document records that will be protected within the enclosure. A legend sheet will be permanently attached to the door for system required documentation, key contacts and system information. The FAD will have securely mounted inside a minimum of 4 Gigabyte digital flash memory drive with a standard USB B connector for uploading and downloading information. The drive shall not be accessible without tools to any person whom gains access to the records. The enclosure shall also provide 2 key ring holders with a location to mount standard business type cards for key contact personnel. USB Storage Interface - Requires Standard USB-13 Connector Pmpu,ty Info,madmn Mh6mum Reqaksd Dwcwn.ntalion (SIGUN) _____________ litvwPn.fla131.7S1) I Wtt.tsflltflflflhiwlmd•1 Cwljflcatjons and Appaavils 16.1 SyItma St,ftetinn CmitaaItSr - 5 .wn ___________________ wwtmspitssS.IIWSL dlsc.dnl,.twtmeama.Nba,s.ba, I-v-lit-it-a Imoa.a..S.o.sm.lmda 16.5 *1dltaLsacaoap at,Ncaa.S.amla00...dlntla 1Witt .a&at Ita,flesrwndwk—a..mwa.ONl.alntuaj flli.dlawh ..dgJw,5gthONaat75Jfl7fl gltn it flav,d..sac Eqalpment Inføamidon lavam. LTIONII Rawl Legend sheet for storing system information including contacts, sign-off, maintenance & test information, and alternate locations of additional records. Space Age Electronics, Inc. www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax No Excuses, Just Solutions! Ordering Information: Part # Description SSU00685 Fire Alarm Storage Cabinet RED SSU00686 Custom screening with your Logo Check out our Infinity line eFAD single gang 2 Gig digital storage solutions (IAMEFAD) This document is subject to change without notice, see doc # E00479 for legal disclaimer ED0549 LTI 0559 Rev.D 2/2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0553:0111 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SPACE AGE ELECTRONICS58 Chockett Road, Sterling, MA 01564 Contact: Robert Scholl (508) 485-0966 Fax (508) 485-4740 Email: bobs@lsae.com DESIGN: Models MBC and BCA battery cabinet enclosures. Minimum thickness .064" cold rolled steel, for batteries with a combined peak voltage of 42.4v. Refert o listees data sheets, installation instrucxtions, and manufacturer's drawings for detailed product description, installation, and operational considerations. INSTALLATION: In accordance with listees printed installation instructions, applicable codes and standards, and in a manner accdeptable to the Authority Having Jurisdiction. MARKING: Listees name, model number, use of product, and UL label. APPROVAL: Listed as a fire alarm equipment battery cabinet enclosure for use with listees fire alrm equipment. Refer to listees instalation instruction manual for details. 02-09-16 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct ' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division bBergelectric NATIONAL TECHNOLOGY SYSTEMS Submittal No. FA-001 Grand Pacific Resorts - Distribution Building Grand Pacific Drive Carlsbad, CA 920008 Bergelectric WO #: 114440 TAB #2 Addressable Sprinkler Monitoring System Intelligent Initiating Devices EDWARDS Catalog Intelligent Initiating Devices United Technologies LIFE SAFETY e INCIDENT MANAGEMENT Intelligent Smoke Detector (SIGA-PD)1 H 1 loom amok " 1t -0 - - Overview The Signature Series SIGA-PD optical smoke detector brings ad- vanced sensing technology to a practical design that increases ef- ficiency, saves installation time, cuts costs, and extends life safety and property protection capabilities. Continuous self-diagnostics ensure reliability over the long-haul, while environmental compen- sation helps reduce maintenance costs. Like all Signature Series detectors, the SIGA-PD is an intelligent device that gathers analog information from its optical sensor, converting this data into digital signals. To make an alarm decision, the detector's on-board microprocessor measures and analyzes sensor readings and compares this information to historical data. Digital filters remove signal patterns that are not typical of fires, thus virtually eliminating unwanted alarms. Standard Features Note: Some features described here may not be supported by all control systems. Check your control panel's Installation and Operation Guide for details. Next Generation Optical Smoke Sensing Technology Wide 0.53 to 3.94 %/ft. (1.7 to 12.35 %/m) smoke obscuration Uses Existing Wiring Automatic Device Mapping Up To 250 Total Signature Addresses Per Loop Two Levels of Environmental Compensation Two Levels of Dirty Detector Warning Twenty Pre-Alarm Settings Five Sensitivity Settings Non-Volatile Memory Electronic Addressing Identification of Dirty or Defective Detectors Automatic Day/Night Sensitivity Adjustment Bicolor (Green/Red) Status Led Standard, Relay, Fault Isolator, and Audible Mounting Bases Sensor Markings Provide Easy Testing Identification Page 1 of 4 DATA SHEET E85001 -0646 Not to be used for installation purposes. Issue 1 Application The SIGA-PD detects extremely small particles of combustion and triggers an alarm at the first sign of smoke. Thanks to its high- performance forward-scattering reflective response technology, the photoelectric smoke sensor responds quickly and reliably to a wide range of fire types, especially slow burning fires fuelled by combustibles typically found in modern multi-use buildings. Compatibility The SIGA-PD detector is compatible only with the Signature Loop Controller. Installation Signature Series detectors. mount to North American 1-gang boxes, 3-1/2 inch or 4 inch octagon boxes, and to 4 inch square elec- trical boxes 1-1/2 inches (38 mm) deep. They mount to European BESA and 1-gang boxes with 60.3 mm fixing centers. See mounting LED indicator base installation and wiring for more information. Sensing and reporting technology The microprocessor in each detector provides additional benefits - Self-diagnostics and History Log, Automatic Device Mapping, and Fast, Stable Communication. Self-diagnostics and History Log - Each Signature Series detector constantly runs self-checks to provide important mainte- nance information. The results of the self-check are automatically updated and permanently stored in the detector's non-volatile memory Automatic Device Mapping - The loop controller learns where each device's serial number address is installed relative to other devices on the circuit. The mapping feature provides supervision of each device's installed location to prevent a detector from being reinstalled (after cleaning etc.) in a different location from where it was originally. Fast Stable Communication - On-board intelligence means less information needs to be sent between the detector and the loop controller. Other than regular supervisory polling response, the detector only needs to communicate with the loop controller when it has something new to report. Testing & Maintenance Each detector automatically identifies when it is dirty or defective and causes a "dirty detector" message. The detector's sensitiv- ity measurement can also be transmitted to the loop controller. A sensitivity report may be printed to satisfy NFPA sensitivity mea- surements, which must be conducted at the end of the first year and every two years thereafter. The user-friendly maintenance program shows the current state of each detector and other pertinent messages. Single detectors may be turned off temporarily from the control panel. Availability 01 maintenance features is dependent on the fire alarm system used. Accessories Detector mounting bases have wiring terminals that are acces- sible from the "room-side" after mounting the base to the electrical box. The bases mount to North American 1-gang boxes and to 31/2 inch or 4 inch octagon boxes, 1½ inches (38 mm) deep. They also mount to European BESA and 1-gang boxes with 60.3 mm fixing centers. The SIGA-SB4, SlGA-RB4, and SIGA-1134 mount to North American 4 inch sq. electrical boxes in addition to the above boxes. They include the SlGA-TS4 Trim Skirt, which is used to cover the "mounting ears" on the base. The SIGA-AB4G mounts to a 4 inch square box only. SIGA-AB401T1LF SIGA-SB SIGA-IB SIOA-RS SIGA-LED Audible Base Standard Base isolator Base Relay Base Remote LED Remote LED SIGA-LED - The remote LED connects to the SlGA-SB or SlGA-SB4 Standard Base only. It features a North American size 1-gang plastic faceplate with a white finish and red alarm LED. SIGA-TS4 Trim Skirt - Supplied with 4 inch bases, it can also be ordered separately to use with the other bases to help hide surface imperfections not covered by the smaller bases. Sounder Bases - Signature Series sounder bases are designed for use where localized or group alarm signaling is required. o SIGA-AB4G bases provide sounder capability to Signature Series to heat and smoke detectors. They are not intended for use with combination carbon monoxide detectors in Fire- plus-CO mode. SlGA-AB4GT bases provide sounder capability to Signature Series smoke and heat detectors, as well as carbon monox- ide detectors when used with a SlGA-TCDR Temporal Pattern Generator. SIGA-AB4G-LF bases provide 520 Hz low frequency sounder capability to Signature Series smoke and heat detec- tors, as well as carbon monoxide detectors when used with a SlGA-TCDR Temporal Pattern Generator. The SlGA-AB4G-LF is suitable for applications requiring low frequency audible tones. Page 2of4 DATA SHEET E85001 0646 Not to be used for installation purposes. Issue 1 Typical Wiring The detector mounting bases accept #18 AWG (0.75mm2), #16 Audible Sounder Bases, Fire Mode (1.0mm2), #14 AWG (1 .5mm2), and #12 AWG (2.5mm2) wire sizes. AB4GTI AB4G, AB4G-LF sounder bases Sizes #16 AWG (1 .omm2) and #18 AWG (0.75mm2) are preferred for ease of installation. Standard Detector Base, SIGA-SB, SIGA-SB4 u IJ Output Mode —Jumpercuts SIGA.AB4G-LF: Default = Fire This is the basic mounting base Remote LED Volume Setting Cut/remove jumper for for EDWARDS Signature Series ii Max resistance Default = High Fire plus CO detectors. The SIGA-LED Re- cfl)___ per wire must Cut/remove jumper for SIGA-AB4G: mote LED is supported by this jJ + __ must .texcem 10 Ohms low dB (Dl Tone Setting Base. i ITonTI Description i r Default = Temporal DATA. DATA-DATA. aa. BIG.Ow IN iriiou Cut/remove jumper for 1 Not Used Steady I l-j--'1] _______ 2 DATA IN/OUT I rr'c 3 Not Used 0 ________________ SIGA-AB4GT: ________________ i 4 DATA IM(-) •,,,. (H I Not Used DATA OUT L...... 4 Remote LED (-) DATA, .rjy, 5 Remote LED I 6 Not Used 7 DATA OUT (-) DATA IN (+1 From Signature Controller DATA OUT 1+) To Nest Device 24 Vdc In From power supply -, - 24 Vdc out or Previous Device or previous base . + To nest base or EOL relay Isolator Detector Base, SIGA-113, SIGA-1B4 Data In Data out - to next Signature device From Signature Controller +5 or previous device This base includes a built-in line fault isolator for use on Class A circuits. A detector must be installed for it to operate. The isolator base does not support the SIGA-LED Remote LED. Warnings & Cautions The isolator operates as follows: This detector does not operate without electrical power. As - a short on the line causes all iso- 0., . ,.. lators to 23 fires frequently cause power interruption, discuss further open within msec ( LA safeguards with the local fire protection specialist. - at 10 msec intervals, beginning on one side r-rER J This detector does not sense fires in areas where smoke of the Class A DATA t (- cfl I" o c- cannot reach the detector. Smoke from fires in walls, roofs, circuit nearest the loop >—1 or on the opposite side of closed doors may not reach the controller, the isolators ) detector. close to provide the DATA IN To DATA OUT (+) Next Device next isolator down the From Signature Controller or Previous Device Photoelectric detectors have a wide range of fire-sensing line with power Term Description I capabilities and are best suited for detecting slow, smolder- 1 - when the isolator next 2 Not Used DATA I WOLFF (+) ing fires. to the short closes, it reopens within 10 I 3 DATA IN I 4 Not Used i In Canada, install according to CAN/U LC-S524 Standard for msec. I 5 6 Not Used DATAOIJr(-) i the Installation of Fire Alarm Systems, CSA C22.1 Canadian The process repeats beginning on the 7 Not Used I Electrical Code, and the local authority having jurisdiction. other side of the loop controller. Relay Detector Base, SIGA-FIB. SlGA-RB4 This base includes a relay. Nor- mally Open or Normally Closed operation is selected during in- stallation. The dry contact is rated for 1 amp (pilot duty) @30 Vdc. The relay's position is supervised to avoid accidentally jarring it out of position. The SIGA-RB can be 0A1 operated as a control relay if pro- grsrrirtieu to uo so tot uie (.oriLrou '"" From Signature Contror TONexiDevice panel. The relay base does not or PmvW D&Ace the SIGA-LED Remote I Term Description I support Normally Open LED. CONTACT RATING I 2 DATA IN/OUT I 1.o Amp O3OVDC I I 3 Common I (Riot Duty) 4 5 6 7 DATA IN (-) I Not UsedI Normally-Closed I DATA OUT (-) I Page 3of4 DATA SHEET E85001 —0646 Not to be Used for installation purposes. Issue 1 Dimensions O WAR DS LIFE SAFETY & INCIDENT MANAGEMENT Contact us... Email: edwards.fire@fs.utc.com Web: Edwards-flre.com EDWARDS is a UTC brand. 1016 Corporate Park Drive Mebane, NC 27302 © 2016 United Technologies Corporation. All rights reserved. Specifications Operating voltage 15.20 to 19.95 VDC Normal operating current 32 pA Alarm current 32 hA Smoke Sensitivity Range ULIULC: 0.53 to 3.94 %/ft. (1.7 to 12.35 %/m) obscuration Vibration level 10 to 35 Hz, with an amplitude of 0.01 in. Air velocity 0 to 4,000 ft./min (0 to 20 m/s) Wail mounting 12 in. (305 mm) max. from ceiling Compatible bases See Ordering Information Compatible detector testers Testiflre 1000, Testifire 2000 Operating environment 32 to 120°F (0 to 49°10), 0 to 93% RH, noncondensing Construction High Impact Engineering Polymer, White Storaae temoerature -4 to 140°F (-20 to 60°C) Environmental UL 268, UL 268A Ordering Information Catalog Ship Wt. Description Number lbs (kg) SIGA-PD Intelligent Optical Smoke Detector 0.4 (0.16) Accessories SIGA-SB Detector Mounting Base - Standard SIGA-SB4 4-inch Detector Mounting Base c/w Trim Skirt SIGA-RB Detector Mounting Base wRelay SIGA-RB4 4-inch Detector Mounting Base w/Relay, c/w Trim Skirt 0.2 (.09) SIGA-IB Detector Mounting Base w/Fault Isolator SIGA-IB4 4-inch Detector Mounting Base w/ Fault Isolator, c/w Trim Skirt SIGA-LED Remote Alarm LED (not for EN54 applications) SIGA-AB413 Audible (Sounder) Base for Fire Detectors 0.3(0.15) SIGA-AB4G-LF Low Frequency Audible (Sounder) Base for CO and Fire Detectors 0.3 (0.15) SlGA-AB4GT Audible (Sounder) Base for CO and Fire Detectors 0.3(0.15) SIGA-TS4 Trim Skirt (supplied with 4-inch bases) 0.1 (0.04) SIGA-TS Trim Skirt - (optional for non 4-inch bases) 0.1 (0.04) SIGA-DMP Detector Mounting Plate 3.0 (1.4) SIGA-RTA Detector Removal Tool SIGA-VA Detector Cleaning Tool Page 4014 DATA SHEET E85001-0646 Not to be used for installation purposes. Issue I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL LISTING SERVICE FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM 01 LISTING No. 7272-1657:0331 Page 1 of I CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, lnc.8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: 0 ModeIiPAnalog addressable photoelectric smoke detector. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 15.2-19.95 Vdc INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72 and applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as an analog addressable photoelectric smoke detector for use with listee's Model EST3 (CSFM# 7165-1657-0186), Model EST3X (CSFM# 7165-1657:0306), Model Quickstart (CSFM# 7165-1657:0207), Models i064,10500, iO1000 (CSFM# 7165-1657:0244) control units and the following listee's bases; SIGA-S13, -SB4, -RB, -RB4, -IB, -1134 (CSFM# 7300-1657-0120), SlGA-A134G (CSFM# 7300-1657-0222), SIGA-AB4GT (CSFM# 7300-1657-0307) and SIGA-AB4G-LF (CSFM# 7300-1657-0322). Suitable for installation inside air ducts for air velocities up to 4,000 feet per minute. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. Model EST3X (CSFM# 7165-1657:0306), Model Quickstart (CSFM# 7165-1657:0207), Models i064, i0500, i01000 (CSFM# 7165-1657:0244)control units NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires, which smolder for hours before bursting into flames. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires, which consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. 08-04-2016 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division EDWARDS Catalog 10, Intelligent Initiating 1Tf Al M I United Technologies LIFE SAFETY INCIDENT MANAGEMENT Intelligent Photoelectric Smoke'Detector (SIGA-) S853 * 7272-1657: 0126 Overview The Signature Series Model SIGA-PS Intelligent Photoelectric Smoke Detector gathers analog information from its smoke sens- ing element and converts it into digital signals. The detector's on-board microprocessor measures and analyzes these signals. It compares the information to historical readings and time patterns to make an alarm decision. Digital filters remove signal patterns that are not typical of fires. Unwanted alarms are virtually elimi- nated. The microprocessor in each detector provides four additional ben- efits - Self-diagnostics and History Log, Automatic Device Map- ping, and Fast, Stable Communication. Self-diagnostics and History Log - Each Signature Series detector constantly runs self-checks to provide important mainte- nance information. The results of the self-check are automatically updated and permanently stored in the detector's non-volatile memory Automatic Device Mapping - The loop controller learns where each device's serial number address is installed relative to other devices on the circuit. The mapping feature provides supervision of each device's installed location to prevent a detector from being reinstalled (after cleaning etc.) in a different location from where it was originally. Fast Stable Communication - On-board intelligence means less information needs to be sent between the detector and the loop controller. Other than regular supervisory polling response, the detector only needs to communicate with the loop controller when it has something new to report. Standard Features Integral microprocessor Non-volatile memory Automatic mapping device Electronic addressing Environmental compensation Intelligent detector Wide 0.67% to 3.770/o/ft. sensitivity range Twenty pre-alarm sensitivity values, set in 5% increments Identification of dirty or defective detectors Automatic day/night sensitivity adjustment Twin RED/GREEN status LEDs Standard, relay, fault isolator, and audible mounting bases Designed and manufactured to ISO 9001 standards Page lof4 DATA SHEET E850010269 Not to be used for installation purposes. Issue 1 , Installation Signature Series detectors mount to North American 1-gang boxes, 3-1/2 inch or 4 inch octagon boxes, and to 4 inch square electrical boxes 1-1/2 inches (38 mm) deep. They mount to Euro- pean BESA and 1-gang boxes with 60.3 mm fixing centers. ,J J 0.8 (20 mm) 2.0 (51 mm) 4A'(1 12 mm) Tamper-Resist Lever Arm -Break off to disable - ®r (Located on Base) Access Slat for ' Tamper-Resist Mechanism Testing & Maintenance Each detector automatically identifies when it is dirty or defective and causes a "dirty detector" message. The detector's sensitiv- ity measurement can also be transmitted to the loop controller. A sensitivity report can be printed to satisfy NFPA sensitivity meas- urements which must be conducted at the end of the first year and every two years thereafter. The user-friendly maintenance program shows the current state of each detector and other pertinent messages. Single detectors may be turned off temporarily from the control panel. Availability of maintenance features is dependent on the fire alarm system used. Scheduled maintenance (Regular or Selected) for proper detec- tor operation should be planned to meet the requirements of the Authority Having Jurisdiction (AHJ). Refer to current NFPA 72 and ULC CAN/ULC 536 standards. Compatibility The SIGA-PS detectors are compatible only with the Signature Loop Controller. Warnings & Cautions This detector will not operate without electrical power. As fires fre- quently cause power interruption, we suggest you discuss further safeguards with your fire protection specialist. This detector will NOT sense fires that start in areas where smoke cannot reach the detector. Smoke from fires in walls, roofs, or on the opposite side of closed doors may not reach the detector to alarm it. Accessories All detector mounting bases have wiring terminals that are acces- sible from the "room-side" after mounting the base to the electri- cal box. The bases mount to North American 1-gang boxes and to 3Y2 inch or 4 inch octagon boxes, 1½ inches (38 mm) deep. They also mount to European BESA and 1-gang boxes with 60.3 mm fixing centers. The SIGA-SB4, SlGA-RB4, and SlGA-1134 mount to North American 4 inch sq. electrical boxes in addition to the above boxes. They include the SIGA-TS4 Trim Skirt which is used to cover the "mounting ears" on the base. The SIGA-AB4G mounts to a 4" sqare box only. SIGA-AB40 SIGA-SB SIGA-113 SIGA-RB SIGA-LED Audible Base Standard Base Isolator Base Relay Base Remote LED Standard Base SIGA-SB, SIGA-SB4 - This is the basic mount- ing base for EDWARDS Signature Series detectors. The SIGA- LED Remote LED is supported by the Standard Base. Relay Base SIGA-RB, SIGA-RB4 - This base includes a relay. Normally open or closed operation is selected during installation. The dry contact is rated for 1 amp (pilot duty) @30 Vdc. The relay's position is supervised to avoid accidentally jarring it out of position. The SIGA-RB can be operated as a control relay if programmed to do so at the control panel (EST3 V.2 only). The relay base does not support the SIGA-LED Remote LED. Audible Base SIGA-AB4G - This base is designed for use where localized or group alarm signaling is required. When the detector senses an alarm condition, the audible base emits a local alarm signal. The optional SlGA-CRR Polarity Reversal Relay can be used for sounding to other audible bases on the same 24 Vdc circuit. Relay and Audible Bases operate as follows: - at system power-up or reset, the relay is de-energized - when a detector is installed in the base with the power on, the relay energizes for four seconds, then de-energizes - when a detector is removed from a base with the power on, the relay is de-energized - when the detector enters the alarm state, the relay is energized. Isolator Base SIGA-11B, SIGA-1B4 - This base includes a built-in line fault isolator for use on Class A circuits. A detector must be installed for it to operate. The isolator base does not support the SIGA-LED Remote LED. The isolator operates as follows: - a short on the line causes all isolators to open within 23 msec - at 10 msec intervals, beginning on one side of the Class A circuit nearest the loop controller, the isolators close to provide the next isolator down the line with power - when the isolator next to the short doses, reopens within 10 msec. The process repeats beginning on the other side of the loop controller. Remote LED SIGA-LED - The remote LED connects to the SIGA-SB or SIGA-SB4 Standard Base only. It features a North American size 1-gang plastic faceplate with a white finish and red alarm LED. SIGA-TS4 Trim Skirt - Supplied with 4 inch bases, it can also be ordered separately to use with the other bases to help hide surface imperfections not covered by the smaller bases. Page 2 of 4 DATA SHEET E85001-0269 Not to be used for installation purposes. Issue 1 Audible Detector Base, SIGA-AB4G eDo® Volume setting Tone setting DefaultHigh volume Default = Temporal pasem Cut for low volume ID (30 Cut for steady tone __V_ To configure output volume or tone, cut the circuit board as shown. 24VdcIn - From power supply or + previous base Data In - From Signature controller or previous device + 24 Vdc out To next base or EOL relay Data out To next Signature device Normally- Normally. DAI UA1n , From Signature Controller or Previous Device Term Description 1 Normally Open 2 DATA IN/OUT 3 Common 4 DATA IN(-) 5 Not Used 6 Normally-Closed 7 DATA OUT (-) CONTACT RATING 1.0 Amp © 30 VDC () pilot Duty) To Next Device Application Although photoelectric detectors have a wide range of fire sensing capabilities they are best suited for detecting slow, smoldering fires. The table below shows six standard test fires used to rate the sensitivity of smoke and heat detectors. The table indicates that no single sensing element is suited for all test fires. EDWARDS recommends that this detector be installed according to latest recognized edition of national and local fire alarm codes. SIGA:HRS and SIGA-HFS Rate-of- SIGA-PHS SIGA-IPHS Test Fire SIGA-PS Photo Rise/ Fixed Temp. Photo Heat 3D Ion/Photo/Heat 4D Open Wood unsuitable optimum very suitable optimum Wood Pyrolysis optimum unsuitable optimum optimum Smouldering Cotton optimum unsuitable optimum optimum Poly Urethane Foam very suitable suitable very suitable optimum n-Heptane very suitable very suitable optimum optimum Liquid Fire without unsuitable optimum very suitable very suitable Smoke Typical Wiring The detector mounting bases accept #18 AWG (0.75mm2), #16 (1.0mm2), #14 AWG (1 .5mm2), and #12 AWG (2.5mm2) wire sizes. Note: Sizes #16 AWG (1 .omm2) and #18 AWG (0.75mm2) are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Standard Detector Base, SIGA-SB, SIGA-SB4 Relay Detector Base, SIGA-RB, SIGA-RB4 Term Description 1 Not Used 2 DATA IN/OUT 3 Not Used 4 DATA IN(-) 4 Remote LED C-) 5 Remote LED 6 Not Used 7 DATA OUT (-) I (-II / I DATA OUT C-) DATA IN 1+1 DATA OUT 1+) From Signature Controller To Next Device or Previous Device Isolator Detector Base, SIGA-IB, SIGA-I134 Term Description 1 Not Used 2 DATA IN/OUT (+) 3 DATA IN (-) 4 Not Used 5 Not Used 6 DATA OUT (-) 7 Not Used DA1 DAT-, From Signature Controller or Previous Device Remote LED Max resistance — per wire must not exceed - 10 Ohms OUT (+) To Next Device OUT (-) Page 3of4 DATA SHEET E850010269 Not to be used for installation purposes. Issue I Specifications Sensing Element Photoelectric - Light Scattering Principle Storage & Operating Environment Air Velocity Range: 0 to 5,000 ft/mm (0 to 25.39 mIs); Humidity: 0 to 93% RH, Non-Condensing Operating Temp: 32°F to 120°F (0°C to 49°C); Storage Temp: -4°F to 140°F (-20'Cto 60°C) Sensitivity Range ULl/ULC - 0.67% to 3.77% obscuration/foot User Selected Alarm Sensitivity Settings Most Sensitive: 1.0%/ft.; More Sensitive: 2.00/o/ft.; Normal: 2.5%/ft.; Less Sensitive: 3.00/o/ft.; Least Sensitive: 3.50/o/ft. Pre-alarm Sensitivity 5% increments, allowing up to 20 pre-alarm settings Operating Voltage 15.2 to 19.95 Vdc (19 Vdc nominal) Operating Current Quiescent: 45pA @ 19 V. Alarm: 45pA @ 19 V. Pulse Current: 100 pA (100 msec). During Communication: 9 mA max. Construction & Finish High Impact Engineering Polymer - White Compatible Mounting Bases SlGA-SB Standard Base, SIGA-RB Relay Base, SIGA-113 Isolator Base, SlGA-AB4, SIGA-AB4G Audible Bases LED Operation On-board Green LED - Flashes when polled; On-board Red LED - Rashes when in alarm. Compatible Remote Red LED (model SIGA-LED) Flashes when in alarm. Compatibility Use With: SIGNATURE Loop Controller Address Requirements Uses one Device Address Agency Listings UL, ULC, MEA, CSFM, FM UL Listed Spacing 30 ft Ordering Information Catalog Description - Ship Wt. Number lbs (kg) SIGA-PS Intelligent Photoelectric Detector - UL/ULC Listed 0.5 (.23) Accessories SIGA-SB Detector Mounting Base - Standard SIGA-SB4 4-inch Detector Mounting Base c/w SIGA-TS4 Trim Skirt SIGA-RB Detector Mounting Base w/Relay SIGA-RB4 4-inch Detector Mounting Base w/Relay, c/w SIGA-TS4 Trim Skirt 0.2 (.09) SIGA-IB Detector Mounting Base w/Fault Isolator SIGA-I134 4-inch Detector Mounting Base w/ Fault Isolator, c/w SIGA-TS4 Trim Skirt SIGA-LED Remote Alarm LED SIGA-AB4G Audible (Sounder) Base .3(0.15) WAR Os LIFE SAFETY & INCIDENT MANAGEMENT Contact us... Email: edwards.fire@fs.utc.com Web: Edwards-fire .com EDWARDS is a UTC brand. 1016 Corporate Park Drive Mebane, NC 27302 © 2016 United Technologies Corporation. All rights reserved. Page 4 of 4 DATA SHEET E85001-0269 Not to be used for installation purposes. Issue I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-1657:0126 Page 1 of I CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, lnc.8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models SlGA-PSand SIGA-PHS photoelectric smoke detectors. Model SIGA-PHS employs an integral 135°F fixed temperature heat sensor. This heat sensor is a supplementary device to the smoke detector and is not approved as a required heat detector. Refer to listee's printed data sheet for additional detailed product description, installation and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with listee's listed fire alarm control units and Model SIGA Series bases (CSFM Listing No. 7300-1657:120). Model SIGA-PS may be suitable for installation directly in the duct with the velocity range from 0-5000 feet/mm. NOTE: Model SIGA-PHS is not intended for use in lieu of a required heat detector. Formerly 7272-1591:126 and 7272-1388:186 7-29-10 ma F! This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division EDWARDS Catalog Intelligent Initiating United Technologies LIFE SAFETY INCIDENT MANAGEMENT Intelligent Duct Smoke Detector Housing (ëIGA-PH) II MEA 3240 LS853J01 Overview The SIGA-DH Duct Smoke Detector Housing is specially engi- neered to exploit all the capabilities of Signature Series intelligent photoelectric and multisensor smoke detectors. EDWARDS Signa- ture Series detectors gather analog information from each of their one or more sensing elements and converts it into digital signals. The detector's onboard microprocessor measures and analyzes these signals. It compares them to historical readings, time pat- terns and known characteristics to make an alarm decision. Digital filters and complex Algorithms are applied for optimum detector accuracy. Unwanted alarms are virtually eliminated. Each duct housing is packaged with detailed installation instruc- tions, gaskets and a self-adhesive drilling template for locating and mounting the detector. The large access door is completely re- movable to allow fast detector installation and field wiring connec- tions. The 16 gauge steel housing is finished in red baked enamel for easy identification. Five one-gang knockouts on the housing provide a convenient location for mounting intelligent Signature Series modules. The SIGA-DH Duct Housing comes with 86 inch (150 mm) exhaust tube. Air sampling tubes are available in lengths from 8 inches (200 mm) to 10 feet (3048 mm) and must be ordered sepa- rately. Compatible smoke detectors, mounting bases, and acces- sories are listed in the Ordering Information. Refer to individual device catalog literature pages for more detail. Standard Features Suitable for high air velocity duct applications Up to 4000 ft/mm. (20.3 rn/sec.) with Photoelectric Detector. Standard Signature Series detectors Designed for use with standard 40, 3D, and Photoelectric Signature Series smoke detectors. Does not require "special" duct smoke heads. Standard, relay, or isolator detector base Detector plugs-in to base then easily installs into housing. Install inducts up to lOft. (3.05 m) wide Remote LED and test station accessories Designed and manufactured to ISO 9001 standards Typical Wiring The detector mounting bases and test station will accept #18 AWG (0.75mm2), #16 (1.0mm2), #14 AWG (1.50mm2) and #12 AWG (2.5 mm2) wire sizes. Note: #14 AWG (1.5 mm2) is not recommended due to difficulty of installation. See Loop Control- ler and Detector catalog sheets for detailed wiring requirement specifications. Page lof4 DATA SHEET E850010325 Not to be used for installation purposes. Issue I Application The SlGA-DH Duct Smoke Detector Housing requires a clear, flat, accessible area on the duct of at least 7-3/8 inches (188mm) W x 7 inches (175mm) H. The duct housing must be installed on ducts at least 8 inches (200mm) wide. Duct detectors are usually installed on the supply duct after the air filters; or in the return air stream prior to being diluted by outside air. Sample tube length must span the entire width of the air duct and the tube can be easily cut to any length. Inlet tubes longer than 3 ft.(900mm) must be supported at both ends. Duct detectors continually sample air flow in a HVAC duct and initiate an alarm condition whenever smoke is detected. An alarm is activated when the quantity (percent obscuration) of combustion products in that air sample exceeds the detector's sensitivity setting. Air velocity in the duct maintains the air flow that enters the detec- tor housing through perforations in the air sampling inlet tube and discharges through the outlet exhaust tube. The detector housing must be installed with its INLET air sampling tube upstream of the EXHAUST tube. Before installing the duct detector housing, test the duct air velocity to verify it is within the limits of the Signature smoke detector that is being installed. Also verify that duct air rela- tive humidity is within 0% and 93%. WARNING: Duct detectors have specific limitations. Duct detec- tors ARE NOT a substitute for an open area smoke detector. Duct detectors ARE NOT a substitute for early warning detection. Duct detectors ARE NOT a replacement for a building's regular fire detection system. Smoke detectors ARE NOT designed to detect toxic gases which can build up to hazardous levels in some fires. These devices WILL NOT operate without electrical power. As fires frequently cause power interruptions, EDWARDS suggests you discuss further safeguards with your local fire protection specialist. Installation and Mounting EDWARDS recommends duct detectors always be installed in ac- cordance with the latest recognized editions of local and national fire alarm codes. Typical Wiring The detector mounting bases and test station will accept #18 AWG (0.75mm2), #16(1.0mm2), #14 AWG (1.50mm2) and #12 AWG (2.5 mmj wire sizes. Note: #14 AWG (1.5 mm) is not recommended due to difficulty of installation. See Loop Control- ler and Detector catalog sheets for detailed wiring requirement specifications. Page 2 of 4 Accessories Duct Detector Air Sampling Tubes One air sampling inlet tube must be ordered for each duct smoke detector housing. Refer to Ordering Information for available lengths. Detector Mounting Bases One detector mounting base must be ordered for each duct smoke housing. Removing a detector from its base (except isola- tor base) does not affect other devices operating on the same data loop. Available bases are: Standard Base SIGA-SB - This is the basic mounting base. The SIGA-LED Remote LED i %. su000rted by the Standard Base. Relay Base SIGA-RB - This base includes P a relay. Normally open or closed operation is selected during installation. The dry contact is rated for 1 amp @ 30 Vdc (pilot duty). The relay's position is supervised to avoid accidentally jarring it out of position. The SIGA-RB can be operated as a control relay if pro- grammed to do so at the control panel (EST3 V. 2 only). The Relay Base does not su000rt the SlGA-LED Remote LED. Relay bases are not affected or activated by the SIGA-DTS Duct Test Station. Isolator Base SIGA-IB - This base includes a built-in line fault isolator. A detector must be installed for it to operate. The integral isolator relay is controlled by the detector or the loop controller. A maximum of 96 isolator bases can be installed on one loop. The Isolator Base does not su000rt the SlGA-LED Remote LED. Alarm LED Indicator - The SlGA-LED Alarm Indicator is suitable for use with the SIGA-SB detector base only. A maximum of one can be operated for each detector. It features a red .'. LED on a one-gang plastic plate and can be installed remote or directly on the SIGA-DH Duct Housing. Duct Test Station iiiii". 1The SIGA-DTS Duct Test Station uses a key switch M ' 10- talong with an integral intelligent input module mounted •1on a two-gang plastic plate. It is supplied with two keys and features a red alarm LED. 0 When the key is turned to the "TEST' position, the LED lights and the integral module remotely inputs a duct detector test alarm. The actions and sequences programmed at the control panel to activate dampers and other smoke control measures, are easily tested. Detector relay bases are not affected or activated. Resetting the control panel clears the test and returns the system to normal. The key cannot be removed when in the "TEST" position. The Duct Test Station mounts to standard 2-inch deep North American two-gang and 4-inch square electric boxes and Euro- pean 100 mm square boxes. Air Velocity Test Kit The 6263-SG Air Velocity Test Kit is specially designed to interface to the SIGA-DH Duct Housing. It is used to test or confirm the air velocity in HVAC ducts where the duct housing is installed. DATA SHEET E85001-0325 Not to be used for installation purposes. Issue I Specifications rcornI.3e Smoke Detectors SIGA-PS - SIGA-PHS SIGA-IPHS Ionization Photoelectric Photoelectric - Unipolar Photoelectric Smoke Sensing Element(s) - ht Principle g e 135" - Light Scattering Principle Heat - - Light Scattering Principle Heat F (57" C) Fixed Temperature - Alarms at 65" F (35"q change in ambient temperature Air Velocity Range 300 to 4000 ft/mm. (1.5 to 20.3 m/sec) 300 to 1000 ft/min. Temperature: 32 - 120" F (0 to Operating Environment 49" C) Temperature: 32 - 100" F (0 - 38" C) Humidity: 0 to 93% RH, Humidity: 0 to 93% RH, non-condensing non-condensing Storage Environment Temperature: -4 to 140" F (-20 to 60" C); Humidity: 0 to 93% RH, non-condensing UU/ULC Sensitivity Range 0.67% to 3.77% obscuration/foot (305mm) obsc mm) Dimensions 7-3/8 inches (188mm) W x 7 inches (178mm) H x 5 inches (127mm) D Material and Finish 16 Gauge Cold Rolled Steel, Red - Baked Enamel Conduit Knockouts Combination 1/2 inch & 3/4 inch Agency Approvals UL, ULC, MEA, CSFM User Selected Sensitivity Settings Least Sensitive: 3.5%; Less Sensitive: 3.0%; Normal: 2.5%; More Sensitive: 2.0%; Most Sensitive: 1.0% Pre-alarm Sensitivity 5 % increments, allowing up to 20 pre-alarm settings Electrical, Physical Characteristics Refer to individual detector catalog sheets Compatible Mounting Bases SIGA-SB Standard Base, SIGA-RB Relay Base, SIGA-IB Isolator Base Compatible Remote LED SIGA-LED (LED flashes when in alarm) Controller Compatibility SIGNATURE Loop Controller Addressing Restrictions Uses one Input Device Address Note: The SIGA-DH Duct Housing is not weatherproof or dust tight.) SIGA-DTS Duct Test Housina Operating Current Standby = 250pA; Activated = 400IJA Operating Voltage 15.2 to 19.95 Vdc (19 Vdc nominal) Replacement Key p/n - P-037449 Storage and Operating Temperature 32 to 120"F (0 to 49"C) Onboard LED Operation Red LED - flashes when in alarm or test state Mounting North American electric box: 2 inch deep 2-gang or 4 inch square; European electric box: 100 mm square Construction & Finish High Impact Engineered Plastic 2-gang front plate - White Addressing Restrictions Uses one Module Address Page 3 of 4 DATA SHEET E85001-0325 Not to be used for installation purposes. Issue I Ordering Information Catalog Number - Description Ship Wt lb. (kg) SIGA-DH Duct Detector Housing 6.5(3.0) Sampling Tubes 6261-001 8 inch (200mm) Air Sampling Inlet Tube 0.25(0.1) 6261-002 24 inch (600mm) Air Sampling Inlet Tube 0.5(0.2) 6261-003 42 inch (1060mm) Air Sampling Inlet Tube 1.6(0.8) 6261-006 78 inch (1980mm) Air Sampling Inlet Tube 2.2 (1.0) 6261-010 120 inch (3048mm) Air Sampling Inlet Tube 4.4(2.0) - Compatible Detectors and Bases SlGA-IPHS 4D Multisensor Detector 0.5(0.23) SlGA-PHS 3D Multisensor Detector 0.5(0.23) SIGA-PS Photoelectric Detector 0.5(0.23) SIGA-SB Standard Base 0.2(0.09) SIGA-RB Relay Base 0.2(0.09) SIGA-IB Isolator Base 0.2 (0.09) Annunciation and Testing SlGA-LED Alarm LED Indicator 0.2 (.09) SlGA-DTS Duct Test Station 0.4 (.18) 6263-SG Duct Air Velocity Test Kit ICE—DWARDS LIFE SAFETY & INCIDENT MANAGEMENT Contact us... Email: edwards.fire@fs.utc.com Web: Edwards-fire.com EDWARDS is a UTC brand. 1016 Corporate Park Drive Mebane, NC 27302 f) 2016 United Technologies Corporation. All rights reserved. Page 4 of 4 DATA SHEET E85001-0325 Not to be used for installation purposes. Issue 1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL 9 FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 3240-1657:0108 Page 1 of I CATEGORY: 3240 -- DUCT SMOKE DETECTOR HOUSING/BASE LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, lnc.8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models 6260(1)-100, 6265(1)-001/-002, 2435P, 1235B, A19863, SIGA-DH, and 6260A-CU Duct Smoke Detector Units. Unit consists of a metal enclosure, relay, electrical components, a separately listed open area detector, a detector base and a sampling and exhaust tubes. Refer to listee's data sheet for additional detailed product description and operational considerations. (1): First four digits followed by an alpha suffix. RATING: 300-4000 fpm except for Model 6260B-100 is range from 400-4000 fpm. Model (IGA-DHWith Model SIGA-IPHS detector head, the sensitivity must be set at Levels I through 4 for velocities over 1000 fpm. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating and UL label. APPROVAL: Listed as duct smoke detector housing units for use with separately listed compatible control units. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 3240-1591:108, 3240-1388:104, 3240-0073:141, 3242-0073:141, 3240-0073:118 and 3241-0073:118 7-29-10 ma This listing Is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division MEA 7150-1657: 01294 ~ S23181 EDWARDS Catalog Intelligent Initiating United Technologies LIFE SAFETY e INCIDENT MANAGEMENT Manual Pull Stations SIGA-270, SIGA-270P, [SIGA-27) Overview The SIGA-270 and SIGA-278 series Manual Pull Stations are part of EDWARDS'S Signature Series system. The SlGA-270 Fire Alarm Manual Pull Stations feature our very familiar teardrop shape. They are made from die-cast zinc and finished with red epoxy powder- coat paint complemented by aluminum colored stripes and mark- ings. With positive pull-lever operation, one pull on the station handle breaks the glass rod and turns in a positive alarm, ensuring protection plus fool-proof operation. Presignal models (SIGA-270P) are equipped with a general alarm (GA) keyswitch for applications where two stage operation is required. The up-front highly visible glass rod discourages tampering, but is not required for proper operation. EDWARDS'S double action single stage SlGA-278 station is a contemporary style manual station made from durable red colored lexan. To initiate an alarm, first lift the upper door marked "LIFT THEN PULL HANDLE", then pull the alarm handle. Standard Features Note: Some features described here may not be supported by all control sys- tems. Check your control panel's Installation and Operation Guide for details. Traditional familiar appearance SIGA-270 models feature our familiar teardrop design with simple positive pull action and sturdy die-cast metal body. One stage (GA), two stage (pre-signal), and double action models SIGA-270 models are available for one or two stage alarm systems. The single stage double action SIGA-278 features a rugged Lexan housing with keyed reset mechanism. Break glass operation An up-front visible glass rod on the SIGA-270 discourages tampering. Intelligent device with integral microprocessor All decisions are made at the station allowing lower com- munication speed while substantially improving control panel response time. Less sensitive to line noise and loop wiring properties; twisted or shielded wire is not required. ADA Compliant Meets ADA requirements for manual pull stations. Electronic Addressing with Non-volatile memory Permanently stores programmable address, serial number, type of device, and job number. Automatically updates historic information including hours of operation, last maintenance date, number of alarms and troubles, and time and date of last alarm. Automatic device mapping Each station transmits wiring information to the loop control- ler regarding its location with respect to other devices on the circuit. Diagnostic LEDs Status LEDs; flashing GREEN shows normal polling; flashing RED shows alarm state. Designed for high ambient temperature operation Install in ambient temperatures up to 120 OF (49 °C). Page 1 of 4 DATA SHEET E85001-0279 Not to be used for installation purposes. Issue I Application The operating characteristics of the fire alarm stations are deter- mined by their sub-type code or "Personality Code". NORMALLY- OPEN ALARM - LATCHING (Pesonality Code 1)is assigned by the factory; no user configuration is required. The device is configured for Class B IDC operation. An ALARM signal is sent to the loop controller when the station's pull lever is operated. The alarm con- dition is latched at the station. Compatibility Signature Series manual stations are compatible only with ED- WARDS'S Signature Loop Controller. Warnings & Cautions This device will not operate without electrical power. As fires fre- quently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. Testing & Maintenance To test (or reset) the station simply open the station and operate the exposed switch. The SIGA-270 series are opened with a tool; the SlGA-278 requires the key which is supplied with that station. The station's automatic self-diagnosis identifies when it is defec- tive and causes a trouble message. The user-friendly maintenance program shows the current state of each Signature series device and other pertinent messages. Single devices may be deactivated temporarily, from the control panel. Availability of maintenance features is dependent on the fire alarm system used. Scheduled maintenance (Regular or Selected) for proper system operation should be planned to meet the requirements of the Authority Having Jurisdiction (AHJ). Refer to current NFPA 72 and ULC CAN/ULC 536 standards. Typical Wiring The fire alarm station's terminal block accepts #18 AWG (0.75mm2) to #12 AWG (2.5mm2) wire sizes. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Wiring Notes Refer to Signature Loop Controller manual for maximum wire distance. 2. All wiring is power limited and supervised. REARVIEW - — of 278 0 o TB2rf Red LED L321 jj Green LED (AbrrnlActK'e) OTB1 5 DATA IN (+) >- (\ ' DATA OUT (+) 1DMA 14(.)> DATAOUT(-) From Signature Controller I To Next Device or Previous Device A Figure 4. Single Stage Systems REAR VIEW — .------------.-- U— Of IF — — I. Il1 yTh'n 8765 S S S Red LED Green LED (Abrm/Acttve) U.loimob TBI C2 CM ril 5 DATA IN (+) ~11- . DATA OUT (+) 1 DATA Ft (.) > DATA From Signature Controller I To Next Device or Previow Device A Figure 5. Two Stage Systems Page 2of4 DATA SHEET E850010279 Not to be used for installation purposes. Issue I Compatible Electrical Box C RE Installation Single-stage Signature Series fire alarm manual pull stations mount to North American 21h inch (64 mm) deep 1-gang boxes. Two stage presignal (270P) models require 11/2 inch (38 mm) deep 4-inch square boxes with i-gang, ½-inch raised covers. Openings must be angular. Rounded openings are not acceptable. Recommended box: Steel City Model 52-C-1 3; in Canada, use Iberville Model Cl- 52-C-49-1/2. All models include terminals are suited for #12 to #18 AWG (2.5 mm2 to 0.75 mm2) wire size. EDWARDS recommends that these fire alarm stations be installed according to latest recognized edition of national and local fire alarm codes. Electronic Addressing: The loop controller electronically addresses each manual station, saving valuable time during system com- missioning. Setting complicated switches or dials is not required. Each station has its own unique serial number stored in its on-board memory. The loop controller identifies each device on the loop and assigns a "soft" address to each serial number. If desired, the stations can be addressed using the SIGA-PRO Signature Program/Service Tool. Key-Latch Electrical Box çCompatible ver:bJ 00 Back 0 Plate Toggle Swftch Gkiss Rod OPE RO Figure 1. SIGA-278 installation Figure 2. SlGA-270, SIGC-270F, SlGC-270B installation Cover Release Figure 3. SlGA-270P, SIGC-270PB installation Page 3 of 4 DATA SHEET E85001-0279 Not to be used for installation purposes. Issue I LIFE SAFETY & INCIDENT MANAGEMENT Contact us... Email: edwards.fire@fs.utc.com Web: Eo'wards-flre.com EDWARDS is a UTC brand. 1016 Corporate Park Drive Mebane, NC 27302 © 2016 United Technologies Corporation. All rights reserved. Specifications - SIGA-270,SIGC- IGA-270P, Catalog Number 270F, SIGC-270B SIGC-270PB SIGA-278 Description Single Action Single Action -Two Double Action - One Stage Stage (Presigna - One Stage Addressing Uses 1 Module Uses 2 Module Uses 1 Module Requirements Address Addresses Address Operating Current Standby = 250pA Standby = 396pA Standby = 250lJA Activated = 400pA I Activated = 680pA Activated = 400i.JA Construction & Finish Diecast Zinc - Red Epoxy Lexan - Red with with aluminum markings white markings Type Code Factory Set Operating Voltage 15.2 to 19.95 Vdc (19 Vdc nominal) Storage and Operating Operating Temperature: 32"F to 120"F (0"C to 49"C) Environment Storage Temperature: -4"F to 140"F (-20"C to 60"C) Humidity: 0 to 93% RH LED Operation On-board Green LED - Flashes when polled On-board Red LED - Flashes when in alarm Compatibility Use With: Signature Loop Controller Agency Listings UL, ULC (note 1), MEA, CSFM, FM Note: SIGC-270F SIGC-2708 and SIGC-270PB are ULC listed only. Suffix "P indicates French markings. Suffix "B" indicates English/French biling ual markings. Ordering Information Catalog Ship Wt. Number Description lbs (kg) SlGA-270 One Stage Fire Alarm Station, English Markings - UL/ULC Listed SIGC-270F One Stage Fire Alarm Station, French Markings - ULC Listed SlGC-270B One Stage Fire Alarm Station, French/English Markings - ULC Listed slGA-270P Two Stage (PresignaQ Fire Alarm Station, English Markings - UL/ULC Listed SIGC- Two Stage (Presigna Fire Alarm Station, French/English Markings 270PB - ULC Listed SlGA-278 Double Action (One Stage) Fire Alarm Station, English Markings - UL/ULC Listed Accessories - - - - - - - - - 276-Ki Station Reset Key, Supplied with all Key Reset Stations -0.1(.05) 27165 12 Glass Rods - for SlGA-270 series (CANADA ONLY) 270-GLR 20 Glass Rods - for SlGA-270 series (USA ONLY) 276-GLR 20 Glass Rods - for SIGA-278 series 276B-RSB Surface Mount Box, Red - for SIGA pull stations 1(0.6) Page 4of4 DATA SHEET E850010279 Not to be used for installation purposes. Issue 1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL I FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-1657:0129 Page 1 of I CATEGORY: 7150 -- FIRE ALARM PULL BOXES LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, lnc.8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models SIGA-270, SlGA-270P, andiGA-278noncoded, intelligent manual pull stations*. Unit consists of a listed pull station and a remote transponder. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as manual pull stations for use with separately listed compatible fire alarm control units. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition with California amendments. NOTE: Formerly 7150-1591:129 and 7150-1388:194 7-29-10 ma This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division bBergelectric NATIONAL TECHNOLOGY SYSTEMS Submittal No. FA-001 Grand Pacific Resorts. Distribution Building Grand Pacific Drive Carlsbad, CA 920008 Bergelectric WO #: 114440 TAB #3 Addressable Sprinkler Monitoring System Intelligent I/O and Control Devices 0 7300-1657: 0121 $3424 SIGA-I MEA EDWARDS Catalog No, Intelligent Input-Output United Technologies LIFE SAFETY ' INCIDENT MANAGEMENT Input, Modules (S1G;k-CT1; SIGA-CT1 HT, SIGA-CT2, SIGA-MCT2 Overview Standard Features The SIGA-CT1 Single Input Module, SIGA-CT1 HT High Tem- perature Single Input Module and SIGA-CT2/SIGA-MCT2 Dual Input Modules are intelligent analog addressable devices used to connect one or two Class B normally-open Alarm, Supervisory, or Monitor type dry contact Initiating Device Circuits (lDC). The actual function of these modules is determined by the "personal- ity code" selected by the installer. This code is downloaded to the module from the Signature loop controller during system configura- tion. The input modules gather analog information from the initiating devices connected to them and convert it into digital signals. The module's on-board microprocessor analyzes the signal and decides whether or not to input an alarm. The SIGA-CTI, SIGA-CT1 HT and SIGA-CT2 mount to standard North American 1-gang electrical boxes, making them ideal for lo- cations where only one module is required. Separate I/O and data loop connections are made to each module. The SIGA-CT1 HI module operates at an expanded temperature range of 32 "F to 158 "F (0 "C to 70 "C) for those applications requiring more extreme environmental temperature variation. The SIGA-MCT2 is part of the UIO family of plug-in Signature Series modules. It functions identically to the SIGA-CT2, but takes advantage of the modular flexibility and easy installation that characterizes all UIO modules. Two- and six-module UIO mother- boards are available. All wiring connections are made to terminal blocks on the motherboard. UIO assemblies may be mounted in EDWARDS enclosures. Multiple applications Including Alarm, Alarm with delayed latching (retard) for water- flow applications, Supervisor and Monitor. The installer selects one of four "personality codes" to be downloaded to the mod- ule through the loop controller. SIGA-CTI HT rated for high temperature environments Suitable for attic installation and monitoring high temperature heat detectors. Plug-in (UIO) or standard 1-gang mount UlO versions allow quick installation where multiple modules are required. The 1-gang mount version is ideal for remote loca- tions that require a single module. Automatic device mapping Signature modules transmit information to the loop controller regarding their circuit locations with respect to other Signature devices on the wire loop. Electronic addressing Programmable addresses are downloaded from the loop con- troller, a PC, or the SIGA-PRO Signature Program/Service Tool. There are no switches or dials to set. Ground fault detection by address Detects ground faults right down to the device level. Page 1 of 4 DATA SHEET E85001-0241 Not to be used for installation purposes. Issue 1 Signature Series Overview The Signature Series intelligent analog-addressable system from EDWARDS Security is an entire family of multi-sensor detectors and mounting bases, multiple-function input and output modules, network and non-network control panels, and user-friendly mainte- nance and service tools. Analog information from equipment con- nected to Signature devices is gathered and converted into digital signals. An onboard microprocessor in each Signature device measures and analyzes the signal and decides whether or not to input an alarm. The microprocessor in each Signature device pro- vides four additional benefits - Self-diagnostics and History Log, Automatic Device Mapping, and Fast, Stable Communication. Self-diagnostics and History Log - Each Signature Series device constantly runs self-checks to provide important mainte- nance information. The results of the self-check are automatically updated and permanently stored in its non-volatile memory. This information is accessible for review any time at the control panel, PC, or using the SlGA-PRO Signature Program/Service Tool. Automatic Device Mapping —The Signature Data Control- ler (SDC) learns where each device's serial number address is installed relative to other devices on the circuit. The SDC keeps a map of all Signature Series devices connected to it. The Signature Series Data Entry Program also uses the mapping feature. With interactive menus and graphic support, the wired circuits be- tween each device can be examined. Layout or "as-built" drawing information showing branch wiring (1-taps), device types and their address are stored on disk for printing hard copy. Installation SIGA-CT1, SIGA-CTI HT and SIGA-CT2: modules mount to North American 21h inch(64 mm) deep 1-gang boxes and 11/2 inch (38 mm) deep 4 inch square boxes with 1-gang covers and SlGA- MP mounting plates. The terminals are suited for #12 to #18 AWG (2.5 mm2 to 0.75 mm2) wire size. Compatible electrical box Wall plate, white (1-gang) LED viewing ports II • . II ¶9 SlGA-MCT2: mount the UIO motherboard inside a suitable ED- WARDS enclosure with screws and washers provided. Plug the SlGA-MCT2 into any available position on the motherboard and secure the module to the motherboard with the captive screws. Wiring connections are made to the terminals on the motherboard (see wiring diagram). UlO motherboard terminals are suited for #12 to #18 AWG (2.5 mm2 to 0.75 mm2) wire size. Page 2 of 4 UIO Motherboard 6-32 self- tapping /i screws plug-In (UIO) Captiw Module screws N6 Flat —Cabinet or electrical enclosure Electronic Addressing - The loop controller electronically ad- dresses each module, saving valuable time during system com- missioning. Setting complicated switches or dials is not required. Each module has its own unique serial number stored in its on-board memory. The loop controller identifies each device on the loop and assigns a "soft" address to each serial number. If desired, the modules can be addressed using the SIGA-PRO Signature Program/Service Tool. EDWARDS recommends that this module be installed according to latest recognized edition of national and local fire alarm codes. Application The duty performed by the SlGA-CT1 and SIGA-CT2/MCT2 is de- termined by their sub-type code or "Personality Code". The code is selected by the installer depending upon the desired application and is downloaded from the loop controller. One personality code can be assigned to the SIGA-CT1. Two per- sonality codes can be assigned to the SIGA-CT2/MCT2. Codes 1, 2, 3 and 4 can be mixed on SIGA-CT2/MCT2 modules only. For example, personality code 1 can be assigned to the first address (circuit A) and code 4 can be assigned to the second address (circuit B). NORMALLY-OPEN ALARM - LATCHING (Personality Code 1) - Assign to one or both circuits. Configures either circuit A or B or both for Class B normally open dry contact initiating devices such as Pull Stations, Heat Detectors, etc. An ALARM signal is sent to the loop controller when the input contact is closed. The alarm condition is latched at the module. NORMALLY-OPEN ALARM - DELAYED LATCHING (Person- ality Code 2) - Assign to one or both circuits. Configures either circuit A or B or both for Class B normally-open dry contact initiat- ing devices such as Waterfiow Alarm Switches. An ALARM signal is sent to the loop controller when the input contact is closed for approximately 16 seconds. The alarm condition is latched at the module. NORMALLY-OPEN ACTIVE - NON-LATCHING (Personality Code 3) - Assign to one or both circuits. Configures either circuit A or B or both for Class B normally-open dry contact monitoring input such as from Fans, Dampers, Doors, etc. An ACTIVE signal is sent to the loop controller when the input contact is closed. The active condition is not latched at the module. NORMALLY-OPEN ACTIVE - LATCHING (Personality Code 4) - Assign to one or both circuits. Configures either circuit A or B or both for Class B normally open dry contact monitoring input such as from Supervisory and Tamper Switches. An ACTIVE signal is sent to the loop controller when the input contact is closed. The active condition is latched at the module. DATA SHEET E85001-0241 Not to be used for installation purposes. Issue 1 Typical Wiring Modules will accept #18 AWG (0.75mm2), #16 (1.0mm2), and #14AWG (1.50mm2), and #12 AWG (2.50mm2) wire sizes. Note: Sizes #16 AWG (1 .omm2) and #18 AWG (0.75mm2) are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Initiating(Slave) Device Circuit Wire Specifications Maximum Allowable Wire Resistance 50 ohms (25 ohms per wire) per Circuit Maximum Allowable Wire Capacitance 0.1lJF per Circuit For Design Reference: Wire Size Maximum Distance to EOLR #18 AWG (0.75 mm2) #16 AWG (1.00 mm2) 4,000 ft (1,21g m) #14 AWG (1.50 mm2) #12 AWG (1.50 mm2) L1 LLStvIe B (Cless B) Red LED (Alarm/Active) Typical N.O. Initiating Device 87 . S S UL/ULC listed 471(5) EOL Green LED (Normal) Typical N.O. Initiating Device INPUT INPUT E. Style B (Class B) Itl ULIULC Listed 471(5) EOL Red LED (Abrm/ActK'e) mi 0 0 4 4 3 2 - I UL/ULC Listed 471(5) EOL Green LED (Normal) f DATA IN (+) 1 DATA II(.)> From Signature Controller or Previous Device SIGA-CT1, SlGA-CT1 HT DATA OUT (+) DATA OUT C-) To Next Device f DATA IN (+)> ' ' DATA OUT(+) 1DATA14(.)> DATAOUT(-) From Signature Controller T To Next Device or Previous Device SlGA-CT2 NOTES Maximum 25 Ohm resistance per wire. Maximum #12 AWG (2.5mm2 ) wire; Minimum #18 AWG (0.75 mm2). Refer to Signature controller installation sheet for wiring specifications. Maximum 10Vdc@350pA The SlGA-ul06R and the SIGA-U102R do not come with TB14. 6 All wiring is supervised and power-limited. 7 These modules will not support 2-wire smoke detectors. J I UUIJLCU,tad MCTS U0Muflmnwftrbwrd for Warnings & Cautions This module will not operate without electrical power. As fires fre- quently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. Compatibility These modules are part of EDWARDS's Signature Series intelligent processing and control platform. They are compatible with EST3, EST3X and iO Series control panels. GriinLEDINa(mab Rid mO SIGA-MCT2 Page 3of4 DATA SHEET E850010241 Not to be used for installation purposes. Issue I LIFE SAFETY & INCIDENT MANAGEMENT Contact us... Email: edwards.fure@fs.utc.com Web: Edwards-fire.com EDWARDS is a UTC brand. 1016 Corporate Park Drive Mebane, NC 27302 @2016 United Technologies Corporation. All rights reserved. Specifications Catalog Number SIGA-CT1HT j SIGA-CT1 SIGA-CT2 I SIGA-MCT2 Description Single Input Module Dual Input Module Type Code 48 (factory set) Four sub-types (personality codes) are available 49 (factory set) Four sub-types (personality codes) are available Address Requirements Uses One Module Address Uses Two Module Addresses Operating Current Standby = 250pA; Activated = 400pA Standby = 396pA; Activated = 680pA Operating Voltage 15.2 to 19.95 Vdc (19 Vdc nominal) Construction High Impact Engineering Polymer Mounting North American 21h inch (64 mm) deep one-gang box- es and 1½ inch (38 mm) deep 4 inch square boxes with one-gang covers and SIGA-MP mounting plates UI02R/6R/6 Motherboard Operating Environment 32°F to 158°F (0°C to 70°C) QO + + ° ' ° Storage Environment -4°F to 140°F (-20°C to 600C); Humidity: 0 to 93% RH LED Operation On-board Green LED - Flashes when polled; On-board Red LED - Flashes when in alarm/active. Compatibility Use with Signature Loop Controller Agency listings UL, ULC, MEA, CSFM Ordering Information Catalog Number . Description Ship Wt. lbs (kg) SIGA-CT1 Single Input Module - UL/ULC Listed 0.4 (0.15) SIGA-CT1 HI Single Input Module High Temperature Operation UL/ULC listed 0.4 (0.15) SIGA-CT2 Dual Input Module - UL/ULC listed 0.4(0.15) SIGA-MCT2 Dual Input Plug-in (UIO) Module - UL, ULC listed 0.1 (0.05) Related Equipment 27193-11 Surface Mount Box - Red, 1-gang 1.0(0.6) 27193-16 Surface Mount Box - White, 1-gang 1.0(0.6) SIGA-Ul02R Universal Input-Output Module Board w/Riser Inputs 0.32 (0.15) - Two Module Positions SIGA-U106R Universal Input-Output Module Board w/Riser Inputs 0.62 (0.28) - Six Module Positions SIGA-Ul06 Universal Input-Output Module Board - Six Module Positions 0.56(0.25) MFC-A Multifunction Fire Cabinet - Red, supports Signature Module 7.0(3.1) Mounting Plates SIGA-MB4 Transponder Mounting Bracket (allows for mounting 0.4(0.15) two 1-gang modules in a 2-gang box) Page 4 of 4 DATA SHEET E85001-0241 Not to be used for installation purposes. Issue 1 EDWARDS Catalog Intelligent Input-Output United Technologies LIFE SAFETY INCIDENT MANAGEMENT Input Modules SIGA-MM1 &IGA-WTM1 Overview The SIGA-MM1 Monitor Module and SIGA-WTM Waterflow/ Tamper Module are part of EDWARDS'S Signature Series system. They are intelligent analog addressable devices used to connect one or two Class B normally-open Alarm, Supervisory, or Monitor type dry contact Initiating Device Circuits (IDC). The function of the SIGA-MM1 and SIGA-WIM is determined by the factory loaded "personality code". The input modules gather analog information from the initiating devices connected to them and convert it into digital Signals. The module's on-board microprocessor analyzes the signal and decides whether or not to input an alarm. The microprocessor in each module provides four additional ben- efits - Self-diagnostics and History Log, Automatic Device Map- ping, Stand-alone Operation and Fast, Stable Communication. S3424 0 7300-1657; 0121 Standard Features Monitor and water? low/tamper applications Includes Alarm with delayed latching (retard) for waterfiow applications, Supervisory, and Monitor. Non-volatile memory Permanently stores serial number, type of device, and job number. Automatically updates historic information including hours of operation, last maintenance date, number of alarms and troubles, and time and date of last alarm. Automatic device mapping Each module transmits wiring information to the loop control- ler regarding its location with respect to other devices on the circuit. Electronic addressing Permanently stores programmable address; there are no switches or dials to set. Addresses are downloaded from a PC, or the SIGA-PRO Signature Program/Service Tool. Intelligent module c/w integral microprocessor All decisions are made at the module allowing lower communication speed while substantially improving control panel response time. Less sensitive to line noise and circuit wir- ing properties; twisted or shielded wire is not required. Ground fault detection by address Detects ground faults right down to the device level. Designed for high ambient temperature operation Install in ambient temperatures up to 120°F (490C). Page 1 of 4 DATA SHEET E85001-0297 Not to be used for installation purposes. Issue I Application The duty performed by the SIGA-MM1 and SIGA-WTM is de- termined by their factory assigned sub-type code or "Personality Code". SIGA-WTM NORMALLY-OPEN ALARM - DELAYED LATCH- ING (Factory set Personality Code 2) - Assigned to one circuit. Configures circuit 1 for Class B normally-open Waterilow Alarm Switches. An ALARM signal is sent to the loop controller when the input contact is closed for approximately 16 seconds. The alarm condition is latched at the module. SIGA-WTM NORMALLY-OPEN ACTIVE - LATCHING (Factory set Personality Code 4) - Assigned to one circuit. Configures circuit 2 for Class B normally open dry contact Supervisory and Tamper Switches. An ACTIVE signal is sent to the loop controller when the input contact is closed. The active condition is latched at the module. SIGA-MMI NORMALLY-OPEN ACTIVE - NON-LATCHING (Factory set Personality Code 3) - Assigned to one circuit. Configures circuit 1 for Class B normally-open dry contact monitoring input such as from Fans, Dampers, Doors, etc. An ACTIVE signal is sent to the loop controller when the input contact is closed. The active condition is not latched at the modute.Com- patibility The Signature Series modules are compatible only with ED- WARDS'S Signature Loop Controller. Warnings & Cautions This module will not operate without electrical power. As fires fre- quently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. Compatibility These modules are part of EDWARDS'S Signature Series intelligent processing and control platform. They are compatible with EST3, EST3X and 10 Series control panels. Testing & Maintenance The module's automatic self-diagnosis identifies when it is defec- tive and causes a trouble message. The user-friendly maintenance program shows the current state of each module and other perti- nent messages. Single modules may be turned off (de-activated) temporarily, from the control panel. Scheduled maintenance (Reg- ular or Selected) for proper system operation should be planned to meet the requirements of the Authority Having Jurisdiction (AHJ). Refer to current NFPA 72 and ULC CAN/ULC 536 standards. Availability of maintenance features is dependent on the fire alarm system used. Installation The SIGA-MM1 and SIGA-WTM modules mount to North American 2-1/2 inch (64 mm) deep one-gang boxes and 1-1/2 inch (38 mm) deep 4 inch square boxes with one-gang covers and SIGA-MP mounting plates. The terminals are suited for #12 to #18 AWG (2.5 mm2 to 0.75 mm2) wire size. EDWARDS recommends that this module be installed according to latest recognized edition of national and local fire alarm codes. Electronic Addressing - The loop controller electronically addresses each module, saving valuable time during system commissioning. Setting complicated switches or dials is not required. Each module has its own unique serial number stored in its on-board memory. The loop controller identifies each device on the loop and assigns a "soft" address to each serial number. If desired, the modules can be addressed using the SlGA-PRO Signature Program/Service Tool. Personality codes are assigned by the factory. No user configura- tion is required for these modules. te go Page 2 of 4 DATA SHEET E85001-0297 Not to be used for installation purposes. Issue 1 AAA Style B (Class B) S I S Red LED (Alarm/Active) 00 Green LED (NormaD f DATA IN 1 DATA IN From Signature Controller or Previous Device DATA OUT (+) DATA OUT (-) To Next Device Model SIGA-MM1 Typical Wiring The module will accept #18 AWG (0.75mm2), #16(1.0mm2), #14 AWG (1 .50mm2), #12 AWG (2.50mm2) wire sizes. Note: Sizes #16 AWG (1.0mm2) and #18 AWG (0.75mm2) are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. initiating (Slave) Device Circuit Wire Specifications - - Maximum Allowable Wire Resistance 50 ohms (25 ohms per wire) per Circuit Maximum Allowable Wire Capacitance 0.1 pF per Circuit For Design Reference: Wire Size Maximum Distance to EOLR #18 AWG (0.75 mm2) #16 AWG (1.0Omm) 4,000 ft 1219m #14 AWG (1.50 mm #12 AWG (1.50 mm Typical N.O. Waterfbw Contact Typical Supervisory Contact Typical N.O. Monitor Contact r4PUT1 I1PU T2 c__I ._CC_. I - - IT81 1 Style B (Closs B) UL/ULC listed UL/ULC Listed 471(0 EOL AAA 471(0 EOL Green LED Rod LED (Normal) (Alarm/Active) DATA IN (k)> • DATA OUT (+) 1 DATA 11(-)> DATA OUT From Signature Controler T To Next Device or previous Device A Model SIGA-WTM Notes Maximum 25 ohms resistance per wire. Maximum #12 AWG (2.5mm2) wire. Mm. #18 (0.75mm2) Refer to Signature Loop Controller Installation Sheet for wiring specifications. Maximum 10 Vdc @ 350lJA. Al wiring power limited and supervised. This module will NOT support 2-wire smoke detectors. Page 3 of 4 DATA SHEET E85001-0297 Not to be used for installation purposes. Issue I Specifications Catalog Number SIGA-MM1 SIGA-WTM Description Monitor Module Waterflowlramper Module Type Code 48 (factory set personality code 3) 49 (factory set personality code 2,4) Address Requirements Uses One Module Address Uses Two Module Addresses Operating Current Standby = 250pA; Activated = 400pA Standby = 396pA; Activated = 680pA Operating Voltage 15.2 to 19.95 Vdc (19 Vdc nominal) Construction & Finish High Impact Engineering Polymer one-gang front plate - White Storage and Operating Environment Operating Temperature: 32'F to 120"F (0"0 to 49C) Storage Temperature: -4"F to 140"F (-20"C to 60'C) Humidity: 0 to 93% RH LED Operation On-board Green LED - Rashes when polled On-board Red LED - Flashes when in alarm/active Compatibility Agency Listings Use With Signature Loop Controller UL, ULC, CSFM, MEA Mounting North American 2-1/2 inch (64 mm) deep one-gang boxes and 1-1/2 inch (38 mm) deep 4 inch square boxes with one-gang covers and SIGA-MP mounting plates. I OUMALI :1 MIT LIFE SAFETY & INCIDENT MANAGEMENT Contact us... Email: edwards.fire@fs.utc.com Web: Edwards-ffre.com EDWARDS is a UTC brand. 1016 Corporate Park Drive Mebane, NC 27302 © 2016 United Technologies Corporation. All rights reserved. Ordering Information ICatalog Description - - - - - - - --- -- Ship VA Number SIGA-MM1 Monitor Module - UL/ULC Listed 0.4 (.15) SIGA-WTM Waterfiow/lamoer Module - UL/ULC Listed Accessories 27193-11 Surface Mount Box - Red, 1-gang 1.0(0.6) 27193-16 Surface Mount Box - White, 1-gang - MFC A Multifunction Are Cabinet - Red, supports Signature Module Mounting Plates 7.0(3.1) SIGA-MB4 Transponder Mounting Bracket (allows for mounting two 1-gang modules in a 2-gang box) 0.4(0.15) SIGA-MP1 Signature Module Mounting Plate, 1 footprint 1.5(0.70) SIGA-MP2 Signature Module Mounting Plate, 1/2 footprint 0.5(0.23) SIGA-MP2L Signature Module Mounting Plate, 1/2 extended footprint 1.02 (0.46) Page 4014 DATA SHEET E85001-0297 Not to be used for installation purposes. Issue 1 0 @ MEA 7300-1657: 0121 I 53424 I RR-MU1 EDWARDS Catalog Intelligent Input/Output I-i United Technologies LIFE SAFETY INCIDENT MANAGEMENT Control Relay Modules (SIGA-CN SIGA-MCR, SIGA- CRR, SIGA-MCRR Overview The Control Relay Module and the Polarity Reversal Relay Module are part of the Signature Series system. They are intelligent analog addressable devices available in either plug-in (UIO) versions, or standard 1-gang mount versions. The SIGA-CR/MCR Control Relay Module provides a Form "C" dry relay contact to control external appliances such as door clos- ers, fans, dampers etc. This device does not provide supervision of the state of the relay contact. Instead, the on-board micro- processor ensures that the relay is in the proper ON/OFF state. Upon command from the loop controller, the SIGA-CR/MCR relay activates the normally open or normally-closed contact. The SlGA-CRR/MCRR Polarity Reversal Relay Module provides a Form "C" dry relay contact to power and activate a series of SIGA-AB4G Audible Sounder Bases. Upon command from the Signature loop controller, the SIGA-CRR reverses the polarity of its 24 Vdc output, thus activating all Sounder Bases on the data loop. Standard-mount versions (SIGA-CR and SIGA-CRR) are installed to standard North American 1-gang electrical boxes, making them ideal for locations where only one module is re- quired. Separate I/O and data loop connections are made to each module. Plug-in UIO versions (SIGA-MCR and SIGA-MCRR) are part of the UIO family of plug-in Signature Series modules. They func- tion identically to the standard mount versions, but take advantage of the modular flexibility and easy installation that characterizes all UIO modules. Two- and six-module UIO motherboards are available. All wiring connections are made to terminal blocks on the motherboard. UIO assemblies may be mounted in EDWARDS enclosures. Standard Features Provides one no/nc contact (SIGA-CR/MCR) Form "C" dry relay contact can be used to control external ap- pliances such as door closers, fans, dampers etc. Allows group operation of sounder bases The SlGA-CRR/MCRR reverses the polarity of its 24 Vdc out- put, thus activating all Sounder Bases on the data loop. Plug-in (UIO) or standard 1-gang mount UIO versions allow quick installation where multiple modules are required. The 1-gang mount version is ideal for remote locations that require a single module. Automatic device mapping Signature modules transmit information to the loop controller regarding their circuit locations with respect to other Signature devices on the wire loop. Electronic addressing Programmable addresses are downloaded from the loop con- troller, a PC, or the SIGA-PRO Signature Program/Service Tool; there are no switches or dials to set. Intelligent device with microprocessor All decisions are made at the module to allow lower com- munication speed with substantially improved control panel response time and less sensitivity to line noise and loop wiring properties; twisted or shielded wire is not required. Page 1 of 6 DATA SHEET E85001-0239 Not to be used for installation purposes. Issue I Installation Application SIGA-CR and SIGA-CRR: modules mount to North American 21h inch (64 mm) deep 1-gang boxes and 1½ inch (38 mm) deep 4 inch square boxes with 1-gang covers and SIGA-MP mounting plates. The terminals are suited for #12 to #18 AWG (2.5 mm2 to 0.75 mm2) wire size. Compatible electrical box Wall plate, white (1-gang) LED viewing ports • \ II SIGA-MCR and SIGA-MCRR: mount the UIO motherboard inside a suitable EDWARDS enclosure with screws and wash- ers provided. Plug the module into any available position on the motherboard and secure the module to the motherboard with the captive screws. Wiring connections are made to the terminals on the motherboard (see wiring diagram). UlO motherboard terminals are suited for #12 to #18 AWG (2.5 mm2 to 0.75 mm2) wire size. UIO Motherboard t 6-32 Mill iL self-tapping LW screws - Plug-In (UIO) Captlw Module screws #6 Flat washers —Cabinet or electrical enclosure The operation of Signature Series control relays is determined by their sub-type code or "Personality Code." Personality Code 8: CONTROL RELAY (SIGA-CR/MCR) - Dry Contact Output. This setting configures the module to provide one Form "C" DRY RELAY CONTACT to control Door Closers, Fans, Dampers, etc. Contact rating is 2.0 amp @ 24 Vdc; 0.5 amp @ 120 Vac (or 0.25A @ 220 Vac for non-UL applications). Personality Code 8 is assigned at the factory. No user configura- tion is required. Personality Code 8: POLARITY REVERSAL RELAY MODULE (SlGA-CRR/MCRR). This setting configures the module to re- verse the polarity of its 24 Vdc output. Contact rating is 2.0 amp @ 24 Vdc (pilot duty). Personality Code 8 is assigned at the factory. No user configuration is required. Compatibility These modules are part of EDWARDS'S Signature Series intelligent processing and control platform. They are compatible with EST3, EST3X and iO Series control panels. Warnings & Cautions This module will not operate without electrical power. As fires fre- quently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. Testing & Maintenance The module's automatic self-diagnosis identifies when it is defec- tive and causes a trouble message. The user-friendly maintenance program shows the current state of each module and other per- tinent messages. Single modules may be turned off (deactivated) temporarily, from the control panel. Availability of maintenance features is dependent on the fire alarm system used. Scheduled maintenance (Regular or Selected) for proper system operation should be planned to meet the requirements of the Authority Hav- ing Jurisdiction (AHJ). Refer to current NFPA 72 and ULC CAN/ ULC 536 standards. Electronic Addressing - The loop controller electronically ad- dresses each module, saving valuable time during system com- missioning. Setting complicated switches or dials is not required. Each module has its own unique serial number stored in its on- board memory. The loop controller identifies each device on the loop and assigns a "soft" address to each serial number. If desired, the modules can be addressed using the SIGA-PRO Signature Program/Service Tool. EDWARDS recommends that this module be installed according to latest recognized edition of national and local fire alarm codes. Page 2 of 6 DATA SHEET E85001-0239 Not to be used for installation purposes. Issue 1 Normally Open Common Normally Closed I, Typical Wiring Modules will accept #18 AWG (0.75mm2), #16 (1.0mm2), #14 AWG (1.50mm2) and #12 AWG (2.5mm2) wire sizes. Note: Sizes #16 AWG (1.0mm2) and #18 AWG (0.75mm2) are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Normally- Normally- Open Common Closed TB2 876 . . Red LED © © (Alarm/Active) 4 3 2 1 TB1 11102mir f DATA IN (.1.) )0 1 DATA IN(-) > From Signature Controller or Previous Device A SIGA-CR Control Relay Data In + Data Out_ Green Re Green LED (Normal) DATA OUT (+) DATA OUT (-) To Next Device Notes Refer to Signature Loop Controller Installation Sheet for wiring specifications. A NFPA 72 requires that the SlGA-CR/SIGA-MCR be installed in the same room as the device it is controlling. This requirement may not apply in all markets. Check with your local AHJ for details. The SIGA-UI06R and the SIGA-UI02R do not come with TB14. A The SIGA-U106 does not come with TB8 through TB13. A Supervised and power-limited. , If the source is nonpower-limited, maintain a space of 1/4 Inch from power-limited wiring or use FPL, FPLP, FPLR, or an equivalent in accordance with the National Electrical Code. 7) Maximum #12 AWG (2.5mm2) wire. Mm. #18 (0.75mm2). No connections required for MCR. Other modules may require connections. No connections required for MCR. Other modules may require connections. SIGA-MCR Control Relay Page 3 of 6 DATA SHEET E85001-0239 Not to be used for installation purposes. Issue I Typical Wiring Modules will accept #18 AWG (0.75mm2), #16(1 .0mm2), #14 AWG (1.50mm2) and #12 AWG (2.50mm2) wire sizes. Note: Sizes #16 AWG (1 .0mm2) and #18 AWG (0.75mm2) are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. A84G AB4G AB4G Audible Base Audible Base Audible Base 6254A-003 EOL Relay Listed 24 VDC Nominal Power Supply S S • CR S CR R 00. 00 SIGA-CRR I S CT1 00 Signature Controller SIGA-CRR Schematic Power h Power Out PoD6weS92 Optional CR for disabling/disconnecting sounder base SlGA-MCRR Schematic Power In Power Out Polarity reverses - + when activated. FAI SIGA-MCRR -4 Notes A Refer to the Signature controller installation sheet for wiring. One Pair of Wires (24 Vdc power). One Pair of Wires (Signature Data). ,4, Single Wire (24 Vdc power). The SIGA-U106R and the SIGA-ul02R do not come with 1814. The SIGA-U106 does not come with TB8 through TB13. SupeMsed and power-limited. If the source is nonpower-limited, maintain a space of 1/4 inch from power-limited wiring or use FPL, FPLR FPLR, or an equivalent in accordance with the National Electrical Code. 9 Maximum #12 AWG (2.5mm2) wire; Minimum #18 AWG (0.75mm2). 10 End-of-Line Relay must monitor and report power supply trouble to control panel. 11 Class B Data wiring may be NT-tapped." Signature - Data Data Out 4. Circuit Data Out Signature Data Circuit Data In Green LED lNormsll Red LED lActivel Optional MCRR or MCR for disabling/disconnecting an audible base. Page 4 of 6 DATA SHEET E85001-0239 Not to be used for installation purposes. Issue 1 Specifications [Catalog Number - - SIGA-CR SIGA-MCR - SiGA-CRR SIGA-MCRR Description Control Relay Polarity Reversal Relay . Type Code Personality Code 8 (Factory Set) Personality Code 8 (Factory Set) Address Requirements Uses 1 Module Address Operating Current Standby =75 pA Activated = 75 pA Operating Voltage 15.2 to 19.95 Vdc (19 Vdc nominal) Relay Type and Rating Form C, 2 Amps @ 24 Vdc (pilot duty), 0.5 Amps @ 120 Vac and 0.25 Amps @ 220 Vac (220 Vac is non-UL) Not rated for capacitive loads. Mounting North American 21h inch (64 mm) deep 1-gang boxes and 1½ inch (38 mm) deep 4 inch square boxes with 1-gang covers and SIGA- MP mounting plates Plugs into UI02R, U106R or U106 Motherboards North American 21h inch (64 mm) deep 1 -gang boxes and 1½ inch (38 mm) deep 4 inch square boxes with 1-gang covers and SIGA- MP mounting plates Plugs into UI02R, UI06R or U106 Motherboards Construction & Finish High Impact Engineering Polymer Storage and Operating Environment Operating Temperature: 32°F to 120°F (0°C to 49°C) Storage Temperature: -4°F to 140°F (-20°C to 60°C) Humidity: 0 to 93% RH LED Operation On-board Green LED - Flashes when polled On-board Red LED - Flashes when in alarm/active Compatibility Use With: Signature Loop Controller Agency Listings UL, ULC, CSFM, MEA Ordering Information r - ______ -- Ship Weight Catalog Number Description (kg) SIGA-CR Control Relay Module (Standard Mount) 0.4(0.15) SIGA-MCR Control Relay Module (UlO Mount) 0.18(0.08) SlGA-CRR Polarity Reversal Relay Module (Standard Mount) 0.4 (0.15) SIGA-MCRR Polarity Reversal Relay Module (UIO Mount) 0.18(0.08) ReiafciEquipment .. . ... . i . -. 27193-11 Surface Mount Box - Red, 1-gang 1(0-6) 27193-16 Surface Mount Box - White, 1-gang 1(0.6) SlGA-Ul02R Universal Input-Output Module Board w/Riser Inputs - Two Module Positions 0.32 (0.15) SIGA-UI06R Universal Input-Output Module Board w/Riser Inputs - Six Module Positions 0.62 (0.28) SIGA-U106 Universal Input-Output Module Board - Six Module Positions 0.56(0.25) SIGA-AB4G Audible (Sounder) Detector Base 0.3 (0.15) Accessories ....... : . . ... MFC-A Multifunction Fire Cabinet - Red, supports Signature Module Mounting Plates 7.0(3.1) SlGA-MB4 Transponder Mounting Bracket (allows for mounting two 1-gang modules in a 2-gang box) 0.4 (0.15) SIGA-MP1 Signature Module Mounting Plate, 1 footprint 1.5(0.70) SIGA-MP2 Signature Module Mounting Plate, 1/2 footprint 0.5(0.23) SIGA-MP2L Signature Module Mounting Plate, 1/2 extended footprint . 1.02 (0.46) Page 5of6 . - DATA SHEET E85001-0239 Not to be used for installation purposes. Issue I Signature Series Overview "ICE-0 DS The Signature Series intelligent analog-addressable system from EDWARDS is an entire family of multi-sensor detectors and mounting bases, multiple-function input and output modules, network and non-network control panels, and user-friendly maintenance and LIFE SAFETY & INCIDENT MANAGEMENT service tools. Analog information from equipment connected to Signature devices is gathered and converted into digital signals. An onboard microprocessor in each Signature Contact us... device measures and analyzes the signal and decides whether or not to input an alarm. Email: edwards.fire@fs.utc.com The microprocessor in each Signature device provides four additional benefits - Self-diag- Web: Edwards-flra corn nostics and History Log, Automatic Device Mapping, and Fast, Stable Communication. Self-diagnostics and History Log - Each Signature Series device constantly runs self- 1016 Corporate Park Drive checks to provide important maintenance information. The results of the self-check are Mebane, NC 27302 automatically updated and permanently stored in its non-volatile memory. This information is accessible for review any time at the control panel, PC, or using the SIGA-PRO Signa- © 2016 United Technologies Corporation. ture Program/Service Tool. The information stored in device memory includes: All tights reserved. Device serial number, address, and type Time and date of last alarm Most recent trouble code logged by the detector - 32 possible trouble codes may be used to diagnose faults. Automatic Device Mapping —The Signature Data Controller (SDC) learns where each device's serial number address is installed relative to other devices on the circuit. The SOC keeps a map of all Signature Series devices connected to it. The Signature Series Data Entry Program also uses the mapping feature. With interactive menus and graphic support, the wired circuits between each device can be examined. Layout or "as-built" drawing information showing branch wiring (r-taps), device types and their address are stored on disk for printing hard copy. This takes the mystery out of the installation. The preparation of as-built drawings is fast and efficient. Device mapping allows the Signature Data Controller to discover: Unexpected additional device addresses Missing device addresses Changes to the wiring in the circuit. Most Signature modules use a personality code selected by the installer to determine their actual function. Personality codes are downloaded from the SOC during system configu- ration and are indicated during device mapping. Page 6 of 6 DATA SHEET E85001-0239 Not to be used for installation purposes. Issue 1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1657:0121 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models SIGA-CCI, SIGA-CC2, SIGA-CTI, SIGA-CT1HTIIGA-CT2lGA- SlGA-CRR, SIGA-UM, SIGA-MMI ,'SIGA-WTM SIGA-IM, SIGA-MDM, SIGA-MCT2, SIGA-MCCI, SIGA-MCC2, SIGA-MCR and SIGA-MCRR remote transponders. Models SIGA-AA30 and SIGA-M50 audio amplifiers. Models SIGA-APS and SIGA-APS-220 power supplies. Models SIGA-MB4, SIGA-MPI, SIGA-MP2 and SIGA-MP2L mounting plates. Models SIGA-Ul02R, SlGA-U106 and SIGA-UI06R motherboards. Model CS-SIGA-CCIP releasing module. Models SIGA-CCIS and SIGA-MCCIS Auto-Sync Output Modules. Models MFC-A and MFC-AD Enclosures. Model SIGA-CR2 Control Relay Module. Model SIGA-CII HI; Signature Series High Temperature Single Input Module. *SIGA..CRH High Power Control Relay Module. Refer to listee's data sheet for additional detailed product description and operational consideration. RATING: 15.2 - 19.95 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7300-1591:121 and 7300-1388:178 *Rev ol1116gt 13 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division