Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
7307 BOLERO ST; ; FPR2017-0301
PERMIT REPORT ( dty of Carlsbad Print Date: 09/07/2023 Job Address: 7307 BOLERO ST, CARLSBAD, CA 92009 Permit Type: FIRE-Construction Residential Work Class: Parcel #: 2154913600 Track #: Valuation: $611,996.35 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Permit No: FP112017-0301 Status: Closed - Finaled Single Family Fire Sprinkl Applied: 08/16/2017 Issued: 10/16/2017 DEV2016-0070 Finaled Close Out: 03/19/2021 Final Inspection: INSPECTOR: Workman, Carisa Wang, Cindy Project Title: DEMPSEY RESIDENCE Description: BOLERO (DEMPSEY) RESIDENCE - SFD SPRINKLER (65 HEADS) FPContractor: A AND D FIRE SPRINKLERS INC 7130 CONVOY CT SAN DIEGO, CA 92111-1019 (858) 277-3473 FEE AMOUNT FIRE NFPA 13D Single Family System (Insp/Bldg) $121.00 FIRE NFPA 13D Single Family System (Plan Review) $239.00 FIRE Plan Resub (3rd&Subsequent Submittal/hr) $264.00 Total Fees: $624.00 Total Payments To Date: $624.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov 10. .4 2-OU - O3O FIRE SPRINKLERS INC. A&D FIRE SPRINKLERS INC 7310 CONVOY ST. SAN DIEGO, CA, 92111 858-277-3473 Job Name : Bolero House Building : FP-01 Location : Great Room System : Residential Contract : D-2592 Data File : 3HD-1.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 A&D FIRE SPRINKLERS INC Page 1 Bolero House Date 09-26-17 HYDRAULIC CALCULATIONS for Project name: Bolero House Location: Great Room Drawing no: FP-01 Date: 09-26-17 Design Remote area number: Residential Remote area location: Great Room Occupancy classification: Residential Density: 0.05 - Gpm/SqFt Area of application: - SqFt Coverage per sprinkler: 256 - SqFt Type of sprinklers calculated.- No. of sprinklers calculated: 3 In-rack demand: - GPM Hose streams: 5 - GPM Total water required (including hose streams): - GPM Type of system: Volume of dry or preaction system: - Gal Water supply information Date: Location: Source: Name of contractor: A&D FIRE SPRINKLERS INC Address: 7310 CONVOY ST. / /SAN DIEGO, CA, 92111 Phone number: 858-277-3473 Name of designer: Authority having jurisdiction: Notes: (Include peaking information or gridded systems here.) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C A&D FIRE SPRINKLERS INC Page 2 Bolero House Date 09-26-17 City Water Supply: Demand: CI - Static Pressure : 36.9 Dl - Elevation : 2.092 C2 - Residual Pressure: 33.3 D2 - System Flow : 39.006 C2 - Residual Flow : 500 D2 - System Pressure : 33.360 Hose ( Demand) : 5 D3 - System Demand :44.006 Safety Margin : 3.500 150 140 -- 130 -- p120 -- R0 E100 90 80 u 70 R6° E5° 40 =S2- 30 20 f 10 - ____ _____ ________ T 50 100 150 200 250 300 350 400 450 FLOW (N ' 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary A&D FIRE SPRINKLERS INC Page 3 Bolero House Date 09-26-17 Fitting Legend Abbrev. Name 1/2 % 1 11/4 1Y2 2 2Y2 3 314 4 5 6 8 10 12 14 16 18 20 24 N * CPVC 90Ell Harvel-Spears 4 5 6 7 9 12 13 0 0 0 0 0 0 0 0 0 0 0 0 0* CPVCTee - Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 R* CPVC Coupling Tee - Run 1 1 1 1 1 1 2 2 0 0 0 0 0 0 0 0 0 0 0 0 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with * The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure / Flow Summary - STANDARD A&D FIRE SPRINKLERS INC Page 4 I U,. Date 09-26-17 Node No. Elevation K-Fact Pt Actual Pn Flow Actual Density Area Press Req. P1 11.83 4.9 7.04 na 13.0 0.05 260 7.0 P2 11.83 4.9 7.04 na 13.0 0.05 260 7.0 P3 11.83 4.9 7.04 na 13.0 0.05 260 7.0 2 10.5 7.91 na 3 10.5 7.94 na 4 12.17 7.37 na 5 10.5 8.26 na 12 12.17 7.05 na 13 12.17 7.06 na 14 12.17 7.06 na 11 12.17 7.37 na B 10.5 8.11 na 6 10.5 8.51 na TOR 6.0 11.85 na BOR 3.0 14.7 na UGI -1.0 16.74 na UG2 7.0 14.69 na UG3 7.0 22.91 na 5.0 UG4 7.0 29.29 na SRC 7.0 33.36 na The maximum velocity is 18.16 and it occurs in the pipe between nodes UG4 and SRC Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams - 2007 A&D FIRE SPRINKLERS INC Page 5 ' Bolero House Date 09-26-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn *CALC P1 13.00 1.101 0 5.0 0.330 7.044 K Factor = 4.90 to 150.0 0.0 5.000 -0.147 14 13.0 0.0306 0.0 5.330 0.163 Vel = 4.38 0.0 13.00 7.060 K Factor = 4.89 P2 13.00 1.101 0 5.0 0.330 7.039 K Factor = 4.90 to 150.0 0.0 5.000 -0.147 12 13.0 0.0306 0.0 5.330 0.163 Vel = 4.38 0.0 13.00 7.055 K Factor = 4.89 P3 13.00 1.101 0 5.0 0.330 7.040 K Factor = 4.90 to 150.0 0.0 5.000 -0.147 13 13.0 0.0308 0.0 5.330 0.164 Vel = 4.38 0.0 13.00 7.057 K Factor = 4.89 *INTERIOR 2 17.44 2.003 R 1.0 11.800 7.907 to 150.0 0.0 1.000 0.0 3 17.44 0.0029 0.0 12.800 0.037 Vel = 1.78 3 -13.97 1.101 0 5.0 33.460 7.944 to 150.0 2N 10.0 21.000 -0.723 4 3.47 0.0027 6R 6.0 54.460 0.145 Vel = 1.17 4 0.32 1.101 30 15.0 27.860 7.366 to 150.0 2N 10.0 27.000 0.723 5 3.79 0.0031 2R 2.0 54.860 0.172 Vel = 1.28 5 21.25 2.003 0 10.0 28.670 8.261 to 150.0 5R 5.0 15.000 0.0 6 25.04 0.0056 0.0 43.670 0.244 Vel = 2.55 0.0 25.04 8.505 K Factor = 8.59 2 -17.44 2.003 0 10.0 7.640 7.907 to 150.0 0.0 10.000 4.548 10 -17.44 -0.0029 0.0 17.640 -0.051 Vel = 1.78 0.0 -17.44 12.404 K Factor = -4.95 12 4.43 2.003 0.0 7.540 7.055 to 150.0 0.0 0.0 0.0 13 4.43 0.0003 0.0 7.540 0.002 Vel = 0.45 13 13.01 2.003 2N 18.0 8.870 7.057 to 150.0 0.0 18.000 5.271 10 17.44 0.0028 0.0 26.870 0.076 Vel = 1.78 0.0 17.44 12.404 K Factor = 4.95 12 8.57 2.003 0.0 6.970 7.055 to 150.0 0.0 0.0 0.0 14 8.57 0.0007 0.0 6.970 0.005 Vel = 0.87 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams A&D FIRE SPRINKLERS INC Page 6 $ Damns I_its, lea Date 09-26-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 14 13.00 2.003 20 20.0 31.830 7.060 to 150.0 2N 18.0 40.000 0.0 11 21.57 0.0042 2R 2.0 71.830 0.305 Vel = 2.20 11 -0.32 2.003 0 10.0 12.800 7.365 to 150.0 2N 18.0 29.000 0.723 5 21.25 0.0041 R 1.0 41.800 0.173 VeI= 2.16 0.0 21.25 8.261 K Factor = 7.39 4 -0.32 1.101 2R 2.0 15.060 7.366 to 150.0 0.0 2.000 0.0 11 -0.32 -0.0001 0.0 17.060 -0.001 Vel = 0.11 0.0 -0.32 7.365 K Factor= -0.12 3 13.97 2.003 2N 18.0 51.160 7.944 to 150.0 0 10.0 34.000 0.0 B 13.97 0.0019 6R 6.0 85.160 0.162 Vel = 1.42 B 0.0 2.003 12N 108.0 59.320 8.106 to 150.0 40 40.0 151.000 0.0 6 13.97 0.0019 3R 3.0 210.320 0.399 Vel = 1.42 6 25.04 2.003 4N 36.0 66.960 8.505 to 150.0 7R 7.0 43.000 1.949 TOR 39.01 0.0127 0.0 109.960 1.397 Vel = 3.97 TOR 0.0 2.067 0.0 3.000 11.851 to 120.0 0.0 0.0 2.799 * * Fixed Loss = 1.5 BOR 39.01 0.0163 0.0 3.000 0.049 Vel = 3.73 BOR 0.0 2.009 2N 18.0 7.000 14.699 to 150.0 0.0 18.000 1.732 UGI 39.01 0.0126 0.0 25.000 0.314 Vel = 3.95 0.0 39.01 16.745 K Factor = 9.53 *UNDERGROUND UGI 39.01 2.003 3N 27.0 84.290 16.745 to 150.0 0.0 27.000 -3.465 UG2 39.01 0.0127 0.0 111.290 1.413 Vel = 3.97 UG2 0.0 1.049 0.0 3.610 14.693 to 140.0 0.0 0.0 7.000 * * Fixed Loss = 7 UG3 39.01 0.3368 0.0 3.610 1.216 Vel = 14.48 UG3 5.00 1.049 0.0 5.330 22.909 Qa = 5 to 120.0 0.0 0.0 3.400 * * Fixed Loss = 3.4 UG4 44.01 0.5597 0.0 5.330 2.983 Vel = 16.34 UG4 0.0 0.995 0.0 8.490 29.292 to 150.0 0.0 0.0 0.0 SRC 44.01 0.4792 0.0 8.490 4.068 Vel = 18.16 0.0 44.01 33.360 K Factor = 7.62 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 1'2-- O3O1 FIRE SPRINKLERS INC. A&D FIRE SPRINKLERS INC 7310 CONVOY ST. SAN DIEGO, CA, 92111 858-277-3473 Job Name : Bolero House - Great Room Proof 2 Building : FP-01 Location : Great Room System : Residential Contract : D-2592 Data File : 3HD-2.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 A&D FIRE SPRINKLERS INC Page 1 Bolero House - Great Room Proof 2 Date 09-26-17 HYDRAULIC CALCULATIONS for Project name: Bolero House Location: Great Room Drawing no: FP-01 Date: 09-26-17 Design Remote area number: Residential Remote area location: Great Room Occupancy classification: Residential Density: 0.05 - Gpm/SqFt Area of application: - SqFt Coverage per sprinkler: 256 - SqFt Type of sprinklers calculated: No. of sprinklers calculated: 3 In-rack demand: - GPM Hose streams: 5 - GPM Total water required (including hose streams): -GPM Type of system: Volume of dry orpreaction system: -Gal Water supply information Date: Location: Source: Name of contractor: A&D FIRE SPRINKLERS INC Address: 7310 CONVOY ST.! / SAN DIEGO, CA, 92111 Phone number: 858-277-3473 Name of designer: Authority having jurisdiction: Notes: (Include peaking information or gridded systems here.) @ -Psi Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 ' Water Supply Curve C A&D FIRE SPRINKLERS INC Page 2 Bolero House - Great Room Proof 2 Date 09-26-17 City Water Supply: Demand: Cl - Static Pressure : 36.9 DI - Elevation : 2.092 C2 - Residual Pressure: 33.3 D2 - System Flow : 39.078 C2 - Residual Flow : 500 D2 - System Pressure : 33.409 Hose ( Demand) : 5 D3 - System Demand : 44.078 Safety Margin : 3.451 150 140 130 p120 R° E10° S90 S80 u 70 R6° E5° 40 :&' 30 20 10 -------- 50 00150200 .250 300 350 400 450 FLOW (N" 1.85) C2 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary A&D FIRE SPRINKLERS INC Page 3 Bolero House - Great Room Proof 2 Date 09-26-17 Fitting Legend Abbrev. Name 1/2 % 1 114 11/2 2 21/2 3 31/2 4 5 6 8 10 12 14 16 18 20 24 N * CPVC 90'EII Harvel-Spears 4 5 6 7 9 12 13 0 0 0 0 0 0 0 0 0 0 0 0 0* CPVCTee - Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 R* CPVC Coupling Tee - Run I I I 1 1 1 2 2 0 0 0 0 0 0 0 0 0 0 0 0 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with * The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure / Flow Summary - STANDARD A&D FIRE SPRINKLERS INC Page 4 n_i___ I •_._... i__i n____ n___t at Date 09-26-17 Node No. Elevation K-Fact Pt Actual Pn Flow Actual Density Area Press Req. P4 11.83 4.9 7.08 na 13.04 0.05 260 7.0 P5 11.83 4.9 7.08 na 13.04 0.05 260 7.0 P6 11.83 4.9 7.04 na 13.0 0.05 260 7.0 2 10.5 7.98 na 3 10.5 . 8.01 na 4 12.17 7.36 na 5 10.5 8.26 na 15 12.17 7.1 na 16 12.17 7.1 na 17 12.17 7.05 na 23 12.17 7.1 na 11 12.17 7.35 na B 10.5 8.16 na 6 10.5 8.52 na TOR 6.0 11.87 na BOR 3.0 14.72 na UGI -1.0 16.76 na UG2 7.0 14.72 na UG3 7.0 22.94 na 5.0 UG4 7.0 29.33 na SRC 7.0 33.41 na The maximum velocity is 18.19 and it occurs in the pipe between nodes UG4 and SRC Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams - 2007 A&D FIRE SPRINKLERS INC Page 5 Bolero House - Great Room Proof 2 Date 09-26-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn *CALC P4 13.04 1.101 0 5.0 0.330 7.082 K Factor = 4.90 to 150.0 0.0 5.000 -0.147 15 13.04 0.0308 0.0 5.330 0.164 Vel = 4.39 0.0 13.04 7.099 K Factor = 4.89 P5 13.04 1.101 0 5.0 0.330 7.081 K Factor = 4.90 to 150.0 0.0 5.000 -0.147 16 13.04 0.0308 0.0 5.330 0.164 Vel = 4.39 0.0 13.04 7.098 K Factor= 4.89 P6 13.00 1.101 0 5.0 0.330 7.039 K Factor =4.90 to 150.0 0.0 5.000 -0.147 17 13.0 0.0306 0.0 5.330 0.163 Vel = 4.38 0.0 13.00 7.055 K Factor = 4.89 *INTERIOR 2 15.70 2.003 R 1.0 11.800 7.978 to 150.0 0.0 1.000 0.0 3 15.7 0.0023 0.0 12.800 0.030 Vel = 1.60 3 -13.26 1.101 0 5.0 33.460 8.008 to 150.0 2N 10.0 21.000 -0.723 4 2.44 0.0014 6R 6.0 54.460 0.076 Vel = 0.82 4 1.39 1.101 30 15.0 27.860 7.361 to 150.0 2N 10.0 27.000 0.723 5 3.83 0.0032 2R 2.0 54.860 0.175 Vel = 1.29 5 21.99 2.003 0 10.0 28.670 8.259 to 150.0 5R 5.0 15.000 0.0 6 25.82 0.0059 0.0 43.670 0.259 Vel = 2.63 0.0 25.82 8.518 K Factor = 8.85 2 -15.70 2.003 0 10.0 7.640 7.978 to 150.0 0.0 10.000 4.548 10 -15.7 -0.0024 0.0 17.640 -0.042 Vel = 1.60 0.0 -15.70 12.484 K Factor= -4.44 15 15.70 2.003 2N 18.0 30.500 7.099 to 150.0 0.0 18.000 5.271 10 15.7 0.0024 0.0 48.500 0.114 Vel = 1.60 0.0 15.70 12.484 K Factor = 4.44 15 -2.66 2.003 R 1.0 6.670 7.099 to 150.0 0.0 1.000 0.0 16 -2.66 -0.0001 0.0 7.670 -0.001 Vel = 0.27 16 13.04 2.003 0.0 4.870 7.098 to 150.0 0.0 0.0 0.0 23 10.38 0.0010 0.0 4.870 0.005 Vel = 1.06 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 , Final Calculations - Hazen-Williams - A&D FIRE SPRINKLERS INC I Page 6 Date 09-26-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 10.38 7.103 K Factor = 3.89 17 13.00 1.101 0.0 1.580 7.055 to 150.0 0.0 0.0 0.0 23 13.0 0.0304 0.0 1.580 0.048 Vel = 4.38 23 10.38 2.003 20 20.0 12.500 7.103 to 150.0 2N 18.0 38.000 0.0 11 23.38 0.0049 0.0 50.500 . 0.249 Vel = 2.38 11 -1.39 2.003 0 10.0 12.800 7.352 to 150.0 2N 18.0 29.000 0.723 5 21.99 0.0044 R 1.0 41.800 0.184 VeI= 2.24 0.0 21.99 8.259 K Factor = 7.65 4 -1.39 1.101 2R 2.0 15.060 7.361 to 150.0 0.0 2.000 0.0 11 -1.39 -0.0005 0.0 17.060 -0.009 Vel = 0.47 0.0 -1.39 7.352 K Factor = -0.51 3 13.26 2.003 2N 18.0 51.160 8.008 to 150.0 0 10.0 34.000 0.0 B 13.26 0.0017 6R 6.0 85.160 0.147 Vel = 1.35 B 0.0 2.003 12N 108.0 59.320 8.155 to 150.0 40 40.0 151.000 0.0 6 13.26 0.0017 3R 3.0 210.320 0.363 Vel = 1.35 6 25.82 2.003 4N 36.0 66.960 8.518 to 150.0 7R 7.0 43.000 1.949 TOR 39.08 0.0127 0.0 109.960 1.401 Vel = 3.98 TOR 0.0 2.067 0.0 3.000 11.868 to 120.0 0.0 0.0 2.799 * * Fixed Loss = 1.5 BOR 39.08 0.0167 0.0 3.000 0.050 Vel = 3.74 BOR 0.0 2.009 2N 18.0 7.000 14.717 to 150.0 0.0 18.000 1.732 UGI 39.08 0.0126 0.0 25.000 0.314 Vel = 3.96 0.0 39.08 16.763 K Factor = 9.55 *UNDERGROUND UGI 39.08 2.003 3N 27.0 84.290 16.763 to 150.0 0.0 27.000 -3.465 UG2 39.08 0.0127 0.0 111.290 1.418 Vel = 3.98 UG2 0.0 1.049 0.0 3.610 14.716 to 140.0 0.0 0.0 7.000 * * Fixed Loss = 7 UG3 39.08 0.3380 0.0 3.610 1.220 Vel = 14.51 UG3 5.00 1.049 0.0 5.330 22.936 Qa = 5 to 120.0 0.0 0.0 3.400 * * Fixed Loss = 3.4 UG4 44.08 0.5615 0.0 5.330 2.993 Vel = 16.36 UG4 0.0 0.995 0.0 8.490 29.329 to 150.0 0.0 0.0 0.0 SRC 44.08 0.4806 0.0 8.490 4.080 Vel = 18.19 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 , Final Calculations - Hazen-Williams A&D FIRE SPRINKLERS INC Page 7 Bolero House - Great Room Proof 2 Date 09-26-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 44.08 33.409 K Factor= 7.63 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 P2-oL- oso FIRE SPRINKLERS INC. A&D FIRE SPRINKLERS INC 7310 CONVOY ST. SAN DIEGO, CA, 92111 858-277-3473 Job Name : Bolero House-Great Room 3 Building : FP-01 Location : Great Room System : Residential Contract : D-2592 Data File : 3HD-3.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 A&D FIRE SPRINKLERS INC Page 1 Bolero House-Great Room 3 Date 09-26-17 HYDRAULIC CALCULATIONS for Project name: Bolero House Location: Great Room Drawing no: FP-01 Date: 09-26-17 Design Remote area number: Residential Remote area location: Great Room Occupancy classification: Residential Density: 0.05 - Gpm/SqFt Area of application: - SqFt Coverage per sprinkler: 256 - SqFt Type of sprinklers calculated: No. of sprinklers calculated: 3 In-rack demand: - GPM Hose streams: 5 - GPM Total water required (including hose streams): -GPM Type of system: Volume of dry orpreaction system: -Gal Water supply information Date: Location: Source: Name of contractor: A&D FIRE SPRINKLERS INC Address: 7310 CONVOY ST.! I SAN DIEGO, CA, 92111 Phone number: 858-277-3473 Name of designer: Authority having jurisdiction: Notes: (Include peaking information or gridded systems here.) @ -Psi Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C A&D FIRE SPRINKLERS INC Page 2 Bolero House-Great Room 3 Date 09-26-17 City Water Supply: Demand: Cl - Static Pressure : 36.9 Dl - Elevation : 1.299 C2 - Residual Pressure: 33.3 D2 - System Flow : 39.331 C2 - Residual Flow : 500 D2 - System Pressure : 34.846 Hose ( Demand) : 5 D3 - System Demand : 44.331 Safety Margin : 2.014 150 140 130 p120 R° E10° S 90 S80 U70 R6° E5° 40 I: 30 20 I I I I 10 I 50 Ul 100 150 200 250 300 350 400 450 FLOW ( N A 1.85) C2 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary A&D FIRE SPRINKLERS INC Page 3 Bolero House-Great Room 3 Date 09-26-17 Fitting Legend Abbrev. Name 1/2 % 1 11/4 11/2 2 2Y2 3 3Y2 4 5 6 8 10 12 14 16 18 20 24 N * CPVC 90Ell Harvel-Spears 4 5 6 7 9 12 13 0 0 0 0 0 0 0 0 0 0 0 0 0* CPVCTee - Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 R * CPVC Coupling Tee - Run 1 1 1 1 1 1 2 2 0 0 0 0 0 0 0 0 0 0 0 0 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *• The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure I Flow Summary - STANDARD D FIRE SPRINKLERS INC Page 4 Date 09-26-17 Node No. Elevation K-Fact Pt Actual Pn Flow Actual Density Area Press Req. P7 10.0 4.9 7.04 na 13.0 0.05 260 7.0 P8 11.83 4.9 7.15 na 13.1 0.05 260 7.0 P9 11.83 4.9 7.29 na 13.23 0.05 260 7.0 2 10.5 9.39 na 3 10.5 9.39 na 4 12.17 8.01 na 5 10.5 9.54 na 10 12.17 8.67 na 11 12.17 8.69 na 18 10.0 7.2 na 21 10.0 7.44 na 22 12.17 7.17 na 19 12.17 7.17 na 20 12.17 7.31 na B 10.5 9.52 na 6 10.5 9.83 na TOR 6.0 13.19 na BOR 3.0 16.04 na UGI -1.0 18.09 na UG2 7.0 16.06 na UG3 7.0 24.3 na 5.0 UG4 7.0 30.72 na SRC 7.0 34.85 na The maximum velocity is 18.29 and it occurs in the pipe between nodes UG4 and SRC Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams - 2007 A&D FIRE SPRINKLERS INC Page 5 Bolero House-Great Room 3 Date 09-26-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn *CALC P7 13.00 1.101 N 5.0 0.330 7.039 K Factor =4.90 to 150.0 0.0 5.000 0.0 18 13.0 0.0306 0.0 5.330 0.163 Vel = 4.38 0.0 13.00 7.202 K Factor = 4.84 P8 13.10 1.101 0 5.0 0.330 7.149 K Factor = 4.90 to 150.0 0.0 5.000 -0.147 19 13.1 0.0310 0.0 5.330 0.165 Vel = 4.41 0.0 13.10 7.167 KFactor= 4.89 P9 13.23 1.101 0 5.0 0.330 7.290 K Factor = 4.90 to 150.0 0.0 5.000 -0.147 20 13.23 0.0315 0.0 5.330 0.168 Vel = 4.46 0.0 13.23 7.311 K Factor = 4.89 "INTERIOR 2 -3.43 2.003 R 1.0 11.800 9.393 to 150.0 0.0 1.000 0.0 3 -3.43 -0.0002 0.0 12.800 -0.002 Vel = 0.35 3 -12.19 1.101 3R 3.0 21.750 9.391 to 150.0 2N 10.0 13.000 -0.723 22 -15.62 -0.0431 0.0 34.750 -1.497 Vel = 5.26 0.0 -15.62 7.171 K Factor= -5.83 4 8.76 1.101 30 15.0 27.860 8.010 to 150.0 2N 10.0 27.000 0.723 5 8.76 0.0148 2R 2.0 54.860 0.810 Vel = 2.95 5 18.38 2.003 0 10.0 28.670 9.543 to 150.0 SR 5.0 15.000 0.0 6 27.14 0.0065 0.0 43.670 0.284 Vel = 2.76 0.0 27.14 9.827 K Factor = 8.66 2 3.43 2.003 0 10.0 7.640 9.393 to 150.0 0.0 10.000 -0.723 10 3.43 0.0001 0.0 17.640 0.002 Vel = 0.35 10 0.0 2.003 4N 36.0 52.250 8.672 to 150.0 20 20.0 62.000 0.0 11 3.43 0.0001 6R 6.0 114.250 0.016 Vel = 0.35 11 14.96 2.003 0 10.0 12.800 8.688 to 150.0 2N 18.0 29.000 0.723 5 18.39 0.0032 R 1.0 41.800 0.132 Vel = 1.87 0.0 18.39 9.543 K Factor = 5.95 18 13.00 1.101 0 5.0 2.750 7.202 to 150.0 0.0 5.000 0.0 21 13.0 0.0307 0.0 7.750 0.238 Vel = 4.38 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams A&D FIRE SPRINKLERS INC Page 6 Bolero House-Great Room 3 Date 09-26-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 21 0.0 1.101 2N 10.0 6.870 7.440 to 150.0 0 5.0 15.000 -0.940 22 13.0 0.0307 0.0 21.870 0.671 Vel = 4.38 22 -15.62 1.101 0.0 2.290 7.171 to 150.0 0.0 0.0 0.0 19 -2.62 -0.0017 0.0 2.290 -0.004 Vel = 0.88 19 13.10 1.101 0.0 7.000 7.167 to 150.0 0.0 0.0 0.0 20 10.48 0.0206 0.0 7.000 0.144 Vel = 3.53 20 13.23 1.101 0 5.0 2.500 7.311 to 150.0 0.0 5.000 0.0 4 23.71 0.0932 0.0 7.500 0.699 Vel = 7.99 4 -8.76 1.101 2R 2.0 15.060 8.010 to 150.0 0.0 2.000 0.0 11 14.95 0.0397 0.0 17.060 0.678 Vel = 5.04 0.0 14.95 8.688 K Factor= 5.07 3 12.19 2.003 2N 18.0 51.160 9.391 to 150.0 0 10.0 34.000 0.0 B 12.19 0.0015 6R 6.0 85.160 0.126 Vel = 1.24 B 0.0 2.003 12N 108.0 59.320 9.517 to 150.0 40 40.0 151.000 0.0 6 12.19 0.0015 3R 3.0 210.320 0.310. Vel = 1.24 6 27.14 2.003 4N 36.0 66.960 9.827 to 150.0 7R 7.0 43.000 1.949 TOR 39.33 0.0129 0.0 109.960 1.418 Vel = 4.00 TOR 0.0 2.067 0.0 3.000 13.194 to 120.0 0.0 0.0 2.799 * * Fixed Loss = 1.5 BOR 39.33 0.0167 0.0 3.000 0.050 Vel = 3.76 BOR 0.0 2.009 2N 18.0 7.000 16.043 to 150.0 0.0 18.000 1.732 UGI 39.33 0.0128 0.0 25.000 0.319 Vel = 3.98 0.0 39.33 18.094 K Factor= 9.25 *UNDERGROUND UGI 39.33 2.003 3N 27.0 84.290 18.094 to 150.0 0.0 27.000 -3.465 UG2 39.33 0.0129 0.0 111.290 1.435 Vel = 4.00 UG2 0.0 1.049 0.0 3.610 16.064 to 140.0 0.0 0.0 7.000 * * Fixed Loss = 7 UG3 39.33 0.3418 0.0 3.610 1.234 Vel = 14.60 UG3 5.00 1.049 0.0 5.330 24.298 Qa = 5 to 120.0 0.0 0.0 3.400 * * Fixed Loss = 3.4 UG4 44.33 0.5674 0.0 5.330 3.024 Vel = 16.46 UG4 0.0 0.995 0.0 8.490 30.722 to 150.0 0.0 0.0 0.0 SRC 44.33 0.4857 0.0 8.490 4.124 Vel = 18.29 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams A&D FIRE SPRINKLERS INC t Onlnret U-- t'-f Dnnn, Page 7 Date 09-26-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 44.33 34.846 K Factor = 7.51 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 i- OO FIRE SPRINKLERS INC. A&D FIRE SPRINKLERS INC 7310 CONVOY ST. SAN DIEGO, CA, 92111 858-277-3473 Job Name : Bolero House Building : FP-01 Location : Master Bedroom System : Residential Contract : D-2592 Data File : 2HD.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 A&D FIRE SPRINKLERS INC Page 1 ' Bolero House Date 09-26-17 HYDRAULIC CALCULATIONS for Project name: Bolero House Location: Master Bedroom Drawing no: FP-01 Date: 09-26-17 Design Remote area number: Residential Remote area location: Master Bedroom Occupancy classification: Residential Density: 0.05 - Gpm/SqFt Area of application: - SqFt Coverage per sprinkler: 256 - SqFt Type of sprinklers calculated: No. of sprinklers calculated: 3 In-rack demand: - GPM Hose streams: 5 - GPM Total water required (including hose streams): -GPM Type of system: Volume of dry or preaction system: - Gal Water supply information Date: Location: Source: Name of contractor: A&D FIRE SPRINKLERS INC Address: 7310 CONVOY ST. / / SAN DIEGO, CA, 92111 Phone number: 858-277-3473 Name of designer: Authority having jurisdiction: Notes: (Include peaking information or gridded systems here.) @ -Psi Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C A&D FIRE SPRINKLERS INC Page 2 Bolero House Date 09-26-17 City Water Supply: Demand: Cl - Static Pressure : 36.9 Dl - Elevation : 1.317 C2 - Residual Pressure: 33.3 D2 - System Flow : 26.018 C2 - Residual Flow : 500 D2 - System Pressure : 26.575 Hose ( Demand) : 5 D3 - System Demand : 31.018 Safety Margin : 10.304 150 140 130 -- p120 -- R° E100 -- S90 s 80 U70 R6° E5° 40 30 ) 20 D 10 50 Ull 00150200 .250 300 350 400 450 FLOW (N "1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 C2 Fittings Used Summary A&D FIRE SPRINKLERS INC Page 3 Bolero House Date 09-26-17 Filling Legend Abbrev. Name 1/a % 1 1% 11/2 2 21/2 3 31,4 4 5 6 8 10 12 14 16 18 20 24 N ' CPVC 90E11 Harvel-Spears 4 5 6 7 9 12 13 0 0 0 0 0 0 0 0 0 0 0 0 0* CPVCTee - Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 R * CPVC Coupling Tee - Run 1 1 1 1 1 1 2 2 0 0 0 0 0 0 0 0 0 0 0 0 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with * The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure / Flow Summary - STANDARD A&D FIRE SPRINKLERS INC Page 4 ' Bolero House Date 09-26-17 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Rea. Si 10.04 4.9 7.04 na 13.0 0.05 260 7.0 S2 10.04 4.9 7.06 na 13.02 0.05 260 7.0 1 10.5 7.01 na 2 10.5 7.05 na 3 10.5 7.07 na 4 12.17 6.49 na 5 10.5 7.29 na 9 10.5 7.03 na 10 10.5 7.05 na 11 12.17 6.5 na B 10.5 7.16 na 6 10.5 7.39 na TOR 6.0 10.0 na BOR 3.0 12.82 na UGI -1.0 14.7 na UG2 7.0 11.91 na UG3 7.0 19.48 na 5.0 UG4 7.0 24.45 na SRC 7.0 26.58 na The maximum velocity is 12.8 and it occurs in the pipe between nodes UG4 and SRC Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams - 2007 A&D FIRE SPRINKLERS INC Page 5 Date 09-26-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn *CALC 51 13.00 1.101 N 5.0 0.460 7.039 K Factor =4.90 to 150.0 0.0 5.000 -0.199 1 13.0 0.0306 0.0 5.460 0.167 Vel = 4.38 0.0 13.00 7.007 K Factor = 4.91 S2 13.02 1.101 N 5.0 0.460 7.059 K Factor = 4.90 to 150.0 0.0 5.000 -0.199 9 13.02 0.0306 0.0 5.460 0.167 Vel = 4.39 0.0 13.02 7.027 K Factor= 4.91 *INTERIOR 1 13.00 2.003 N 9.0 4.770 7.007 to 150.0 0 10.0 19.000 0.0 2 13.0 0.0016 0.0 23.770 0.039 Vel = 1.32 2 0.80 2.003 R 1.0 11.800 7.046 to 150.0 0.0 1.000 0.0 3 13.8 0.0019 0.0 12.800 0.024 Vel = 1.41 3 -10.35 1.101 0 5.0 33.460 7.070 to 150.0 2N 10.0 21.000 -0.723 4 3.45 0.0026 6R 6.0 54.460 0.144 Vel = 1.16 4 -1.01 1.101 30 15.0 27.860 6.491 to 150.0 2N 10.0 27.000 0.723 5 2.44 0.0014 2R 2.0 54.860 0.076 Vel = 0.82 5 13.22 2.003 0 10.0 28.670 7.290 to 150.0 SR 5.0 15.000 0.0 6 15.66 0.0024 0.0 43.670 0.103 Vel = 1.59 0.0 15.66 7.393 K Factor= 5.76 2 -0.80 2.003 0 10.0 7.640 7.046 to 150.0 0.0 10.000 0.0 10 -0.8 0.0 0.0 17.640 0.0 Vel = 0.08 0.0 -0.80 7.046 K Factor= -0.30 9 13.02 2.003 0 10.0 1.360 7.027 to 150.0 0.0 10.000 0.0 10 13.02 0.0017 0.0 11.360 0.019 Vel = 1.33 10 -0.81 2.003 4N 36.0 55.210 7.046 to 150.0 20 20.0 61.000 -0.723 11 12.21 0.0015 SR 5.0 116.210 0.172 Vel= 1.24 11 1.01 2.003 0 10.0 12.800 6.495 to 150.0 2N 18.0 29.000 0.723 5 13.22 0.0017 R 1.0 41.800 0.072 Vel = 1.35 0.0 13.22 7.290 K Factor= 4.90 4 1.01 1.101 2R 2.0 15.060 6.491 to 150.0 0.0 2.000 0.0 11 1.01 0.0002 0.0 17.060 0.004 Vel = 0.34 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams A&D FIRE SPRINKLERS INC Page 6 Bolero House Date 09-26-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 1.01 6.495 K Factor = 0.40 3 10.35 2.003 2N 18.0 51.160 7.070 to 150.0 0 10.0 34.000 0.0 B 10.35 0.0011 6R 6.0 85.160 0.093 Vel = 1.05 B 0.0 2.003 12N 108.0 59.320 7.163 to 150.0 40 40.0 151.000 0.0 6 10.35 0.0011 3R 3.0 210.320 0.230 Vel = 1.05 6 15.67 2.003 4N 36.0 66.960 7.393 to 150.0 7R 7.0 43.000 1.949 TOR 26.02 0.0060 0.0 109.960 0.660 Vel = 2.65 TOR 0.0 2.067 0.0 3.000 10.002 to 120.0 0.0 0.0 2.799 * * Fixed Loss = 1.5 BOR 26.02 0.0080 0.0 3.000 0.024 Vel = 2.49 BOR 0.0 2.009 2N 18.0 7.000 12.825 to 150.0 0.0 18.000 1.732 UGI 26.02 0.0059 0.0 25.000 0.148 Vel = 2.63 0.0 26.02 14.705 K Factor = 6.79 *UNDERGROUND UGI 26.02 2.003 3N 27.0 84.290 14.705 to 150.0 0.0 27.000 -3.465 UG2 26.02 0.0060 0.0 111.290 0.668 Vel = 2.65 UG2 0.0 1.049 0.0 3.610 11.908 to 140.0 0.0 0.0 7.000 * * Fixed Loss = 7 UG3 26.02 0.1593 0.0 3.610 0.575 Vel = 9.66 UG3 5.00 1.049 0.0 5.330 19.483 Qa = 5 to 120.0 0.0 0.0 3.400 * * Fixed Loss = 3.4 UG4 31.02 0.2931 0.0 5.330 1.562 Vel = 11.52 UG4 0.0 0.995 0.0 8.490 24.445 to 150.0 0.0 0.0 0.0 SRC 31.02 0.2509 0.0 8.490 2.130 Vel = 12.80 0.0 31.02 26.575 K Factor = 6.02 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 P1o1 FIRE SPRINKLERS INC. A&D FIRE SPRINKLERS INC 7310 CONVOY ST. SAN DIEGO, CA, 92111 858-277-3473 Job Name : Bolero House Building : FP-01 Location : Master WIC System Contract : D-2592 Data File : IHD.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 A&D FIRE SPRINKLERS INC Page 1 Bolero House Date 09/26/17 HYDRAULIC CALCULATIONS for Project name: Bolero House Location: Master WIC Drawing no: FP-01 Date: 09-26-17 Design Remote area number: Remote area location: Master WIC Occupancy classification: Residential Density: 0.05 - Gpm/SqFt Area of application: - SqFt Coverage per sprinkler: 256 - SqFt Type of sprinklers calculated: No. of sprinklers calculated: 3 In-rack demand: - GPM Hose streams: 5-GPM Total water required (including hose streams): - GPM Type of system: Volume of dry or preaction system: - Gal Water supply information Date: Location: Source: Name of contractor: A&D FIRE SPRINKLERS INC Address: 7310 CONVOY ST. / I SAN DIEGO, CA, 92111 Phone number: 858-277-3473 Name of designer: Authority having jurisdiction: Notes: (Include peaking information or gridded systems here.) © -Psi Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C A&D FIRE SPRINKLERS INC Page 2 Bolero House Date 09/26/17 City Water Supply: Demand: Cl - Static Pressure : 36.9 Dl - Elevation : 1.317 C2 - Residual Pressure: 33.3 D2 - System Flow : 20 C2 - Residual Flow : 500 D2 - System Pressure : 36.071 Hose ( Demand) : 5 D3 - System Demand : 25 Safety Margin : 0.814 150 140 130 p120 R11° E10° s 90 80 U70 R6° E5° 40 30 D: 20 10 50 100 150 200 250 300 350 400 450 FLOW (N "1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 C2 Fittings Used Summary A&D FIRE SPRINKLERS INC Page 3 Bolero House Date 09/26/17 Fitting Legend Abbrev. Name V2 % 1 11/4 1Y2 2 21/2 3 31/2 4 5 6 8 10 12 14 16 18 20 24 N * CPVC 90E11 Harvel-Spears 4 5 6 7 9 12 13 0 0 0 0 0 0 0 0 0 0 0 0 0* CPVCTee - Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 R * CPVC Coupling Tee - Run 1 1 1 1 1 1 2 2 0 0 0 0 0 0 0 0 0 0 0 0 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *• The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure / Flow Summary - STANDARD A&D FIRE SPRINKLERS INC ' Bolero House Page 4 Date 09/26/17 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. S3 10.04 4.9 16.66 na 20.0 0.05 400 7.0 2 10.5 18.76 na 3 10.5 18.75 na 4 12.17 18.11 na 5 10.5 18.86 na 10 10.5 18.77 na 11 12.17 18.11 na B 10.5 18.67 na 6 10.5 18.9 na TOR 6.0 21.26 na BOR 3.0 24.07 na UG1 -1.0 25.9 na UG2 7.0 22.84 na UG3 7.0 30.19 na 5.0 UG4 7.0 34.64 na SRC 7.0 36.07 na The maximum velocity is 10.32 and it occurs in the pipe between nodes UG4 and SRC Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams - 2007 A&D FIRE SPRINKLERS INC Page 5 Bolero House Date 09/26/17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn *CALC S3 20.00 1.101 20 10.0 16.500 16.660 K Factor = 4.90 to 150.0 N 5.0 16.000 -0.199 B 20.0 0.0680 R 1.0 32.500 2.211 Vel = 6.74 0.0 20.00 18.672 K Factor = 4.63 *INTERIOR 2 -7.14 2.003 R 1.0 11.800 18.760 to 150.0 0.0 1.000 0.0 3 -7.14 -0.0005 0.0 12.800 -0.007 Vel = 0.73 3 9.60 1.101 0 5.0 33.460 18.753 to 150.0 2N 10.0 21.000 -0.723 4 2.46 0.0014 6R 6.0 54.460 0.076 Vel = 0.83 4 -0.92 1.101 30 15.0 27.860 18.106 to 150.0 2N 10.0 27.000 0.723 5 1.54 0.0006 2R 2.0 54.860 0.033 Vel = 0.52 5 8.06 2.003 0 10.0 28.670 18.862 to 150.0 5R 5.0 15.000 0.0 6 9.6 0.0009 0.0 43.670 0.041 Vel = 0.98 0.0 9.60 18.903 K Factor = 2.21 2 7.14 2.003 0 10.0 7.640 18.760 to 150.0 0.0 10.000 0.0 10 7.14 0.0005 0.0 17.640 0.009 Vel = 0.73 10 0.0 2.003 4N 36.0 55.210 18.769 to 150.0 20 20.0 61.000 -0.723 11 7.14 0.0006 5R. 5.0 116.210 0.064 Vel = 0.73 11 0.92 2.003 0 10.0 12.800 18.110 to 150.0 2N 18.0 29.000 0.723 5 8.06 0.0007 R 1.0 41.800 0.029 Vel = 0.82 0.0 8.06 18.862 K Factor= 1.86 4 0.92 1.101 2R 2.0 15.060 18.106 to 150.0 0.0 2.000 0.0 11 0.92 0.0002 0.0 17.060 0.004 Vel = 0.31 0.0 0.92 18.110 K Factor= 0.22 3 -9.60 2.003 2N 18.0 51.160 18.753 to 150.0 0 10.0 34.000 0.0 B -9.6 -0.0010 6R 6.0 85.160 -0.081 Vel = 0.98 B 20.00 2.003 12N 108.0 59.320 18.672 to 150.0 40 40.0 151.000 0.0 6 10.4 0.0011 3R 3.0 210.320 0.231 Vel = 1.06 6 9.60 2.003 4N 36.0 66.960 18.903 to 150.0 7R 7.0 43.000 1.949 TOR 20.0 0.0037 0.0 109.960 0.406 Vel = 2.04 TOR 0.0 2.067 0.0 3.000 21.258 to 120.0 0.0 0.0 2.799 * * Fixed Loss = 1.5 BOR 20.0 0.0050 0.0 3.000 0.015 Vel = 1.91 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams A&D FIRE SPRINKLERS INC Page 6 Bolero House Date 09/26/17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn BOR 0.0 2.009 2N 18.0 7.000 24.072 to 150.0 0.0 18.000 1.732 UGI 20.0 0.0036 0.0 25.000 0.091 Vel = 2.02 0.0 20.00 25.895 K Factor = 3.93 *UNDERGROUND UGI 20.00 2.003 3N 27.0 84.290 25.895 to 150.0 0.0 27.000 -3.465 UG2 20.0 0.0037 0.0 111.290 0.411 Vel = 2.04 UG2 0.0 1.049 0.0 3.610 22.841 to 140.0 0.0 0.0 7.000 * * Fixed Loss = 7 UG3 20.0 0.0978 0.0 3.610 0.353 Vel = 7.42 UG3 5.00 1.049 0.0 5.330 30.194 Qa = 5 to 120.0 0.0 0.0 3.400 * * Fixed Loss = 3.4 UG4 25.0 0.1966 0.0 5.330 1.048 Vel = 9.28 UG4 0.0 0.995 0.0 8.490 34.642 to 150.0 0.0 0.0 0.0 SRC 25.0 0.1683 0.0 8.490 1.429 Vel = 10.32 0.0 25.00 36.071 K Factor = 4.16 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 3 Badger Meter Recordall® Cold Water Bronze Disc Meter Size 1" (DN 25mm) NSF/ANSI Standard 61 Certified, Annex G DESCRIPTION Badger Meter offers the Recordall Disc meter in Cast Bronze and a Lead-Free Alloy. The Lead-Free Alloy (Trade designation: M55-LL) version has been certified to comply with NSF/ANSI Standard 61, Annex G and carries the NSF-61 Mark on the housing. All components of the Lead-Free Alloy meter, i.e., disc, chamber, housing, seals, etc. comprise the certified system. APPLICATIONS: For use in measurement of potable cold water in residential, commercial and industrial services where flow is in one direction only. OPERATION: Waterflowsthroughthe meter's strainerand into the measuring chamber where it causes the disc to nutate. The disc, which moves freely, nutates on its own ball, guided by a thrust roller. A drive magnet transmits the motion of the disc to a follower magnet located within the permanently sealed register. The follower magnet is connected to the register gear train. The gear train reduces the disc nutations into volume totalization units displayed on the register dial face. OPERATING PERFORMANCE: The Badger Meter Recordall Disc meters meet orexceed registration accuracyforthe lowflow rates (95%), normal operating flow rates (100 ± 1.5%), and maximum continuous operation flow rates as specifically stated by AWWA Standard C700. CONSTRUCTION: Badger Meter Recordall Disc meter construction, which complieswithANSl/AWWA standard C700, consists ofthreebasiccomponents: meter housing, measuring chamber, and permanently sealed register. The water meter is available in bronze and Lead-Free Alloy with externally- threaded spuds. A corrosion-resistant engineered polymer material is used for the measuring chamber. To simplify maintenance, the register, measuring chamber, and strainer can be replaced without removing the meter housing from the installation. No change gearsare required for accuracy calibration. Interchangeabilityof parts among like-sized meters also minimizes spare parts inventory investment. MAGNETIC DRIVE: Direct magnetic drive, through the use of high-strength magnets, provides positive, reliable and dependable register coupling for straight-reading, remote or automatic meter reading options. SEALED REGISTER: The standard register consists of a straight-reading odometer-type totalization display, 3600 test circle with center sweep hand and flow finder to detect leaks. Register gearing consists of self-lubricating engineered polymer gears to minimize friction and provides long life. Permanently sealed; dirt, moisture, tampering and lensfogging problems are eliminated. Multi-position register simplifies meter installation and reading. Automatic meter reading systems are available for all Recordall Disc meters. See the back of this sheet for additional information. All reading options are removable from the meter without disrupting water service. TAMPER-PROOF FEATURES: Customer removal of the register to obtain free water can be prevented when the optional tamper detection seal wire screw or TORX' tamper resistant seal screw is added to the meter. Both can be installed at the meter site or at the factory. MAINTENANCE: Badger Meter Recordall Disc meters are designed and manufactured to provide long-term service with minimal maintenance. When maintenance is required, it can be performed easily either atthe meter installation or at any other convenient location. As an alternative to repair by the utility, Badger Meter offers various maintenance and meter component exchange programs to fit the needs of the utility. CONNECTIONS: Tailpieces/Unions for installations of meters on various pipe types and sizes, including misaligned pipes, are available as an option. Modi SPECIFICATIONS Typical Operating 1-55 GPM (.23 to 12.5 m3/hr) Range (100% ± 1.5%) LowFlow 1/2GPM01 m3/hr) (Mm. 95%) Maximum 40 GPM (9.1 m3/hr) Continuous Operation Pressure Loss 3.4 PSI at40 GPM at Maximum (.23 bar at 9.1 m3/hr) Continuous Operation Maximum Operating 80°F (26°C) Temperature Maximum Operating 150 PSI (10 bar) Pressure Measuring Element Nutating disc, positive displacement Register1,pe Straight reading, sealed magnetic drive standard. Remote reading or Automatic Meter Reading units optional. Register Capacity 10,000,000 Gallons, 1,000,000 Cubic Feet, 100,000 m3. 6 odometer wheels. Meter Connections Available in bronze and engineered polymertofit 1 "(DN25mm)spudthreadbore diameter sizes. See table below. METER SPUD AND CONNECTION SIZES Size "L" B. Coupling Nut Tailpiece Designation x Laying Bore and Pipe Thread Length Dia. Spud Thread (NPT) 1' x 103/4 1° 11/4'(1') 1" MATERIALS Meter Housing Cast Bronze, Lead-Free Alloy Housing Bottom Plates Bronze, Cast Iron, Lead-Free Alloy Measuring Chamber Engineered Polymer Disc Engineered Polymer Trim Stainless Steel, Bronze Strainer Engineered Polymer Disc Spindle Engineered Polymer Magnet Polymer Bonded Magnet Spindle Engineered Polymer Register Lid and Shroud Engineered Polymer, Bronze Generator Housing Engineered Polymer RD-T-55 (4-11) Technical Brief PRESSURE LOSS CHART ACCURACY CHART Rate of Flow, in Gallons per Minute Rate of Flow, in Gallons per Minute 10 .1 1.0 10 : A B B C D METER METER LAYING HEIGHT HEIGHT HEIGHT CENTERLINE METER SIZE MODEL LENGTH REGJRTR TO ADE GEN. TO BASE WIDTH WEIGHT 1" 55 103/4" 6" 61/2" 73/8" 21/32" 61/4" 8.75 lbs. (25mm) (273mm) (152mm) (165mm) (187mm) (52mm) (159mm) Sweep Hand Reqistration MODEL GALLON CU.FT. CU. METER M55 10 1 .1 r AAWK ijillij 55 Recorded" I23 ' Gallons wo RTR and Recordall are registered trademarks of Badger Meter, Inc. Other trademarks appearing in this document are the property of their respective entities. Copyright 2011 Badger Meter, Inc. All rights reserved. Due to continuous research, product improvements and to enhancements, Badger Meter reserves the right to change product or system specifications without notice, except to the extent an outstanding contractual obligation exists. Badger Meter I P.O. Box 245036, Milwaukee, Wisconsin 53224-9536 800-876-3837 Iinfocentral@badgermeter.com I www.badgermeter.com Item Description 1 Manifold Body, Male Thread x Male Thread 2 Inline Check Valve, Spring Loaded 3 Flow Switch with Retard 4 Drain Valve, with optional pressure relief valve 5 Pressure Gauge, 0-300 psi National Fire Products, LLC RESI-RISERTM The RESI-RISERTM is a pre-assembled, compact, attractive fire sprinkler riser unit for residential sprinkler systems in accordance with NFPA 13, 13R and 13D. The RESI-RISERTM manifold is manufactured as a one- piece casting that is air-tested for leaks. Raised lettering on both sides allows the RESl-RlSER" to be installed to the right or left and easily identifies the flow direction and Test and Drain outlet. Two mounting legs are molded onto the manifold allowing for a secure right or left anchoring. The flow switch has dual SPDT switches and a retard of 0-90 seconds. An optional "all in one" cost saving combination Pressure Relief Valve/Test and Drain Valve is available. The RESI-RISERTM unique design gives the ability to be installed within standard 2 x 4 frame construction. Every size RESI-RISERTM fits within a 2 x 4 wall framed at 16 inches on center. Technical Data Sizes: 1", 1W', 1W', and 2" Style: Thread x Thread Listing: Flow Switch and Pressure Gauge are UL Listed Finish (Riser Body): Cast Brass Water Pressure Gauge: 0-300 psi Optional Accessories: 175 psi Pressure Relief Valve/Test and Drain US Patent # 6,076,545 RESI-RISERTm Size Chart Description in 1Y4" 134" 2" Height* 13" 13" 13" 13" Width** 10-3/4" 11-1/2" 12" 12-1/2" Depth 3-1/2" 3-1/2" 3-1/2" 3-1/2- Drain Size 1/2" in 1" 1" Dimensions include all spacing needed to operate drain valve and remove flow switch cover * Without check valve ** With or without pressure relief valve 0 National Fire Products, LLC (800) 528-7978 lormal Position - tatic Pressure Pressure Loss Tables Pressure Loss in 1" Resi-Riser 12 Pressure Relief/Test and Drain How it Works 0 10 15 20 25 30 35 40 Flow (gpm) Pressure Loss in 1-1/4" Resi-Riser - 10 8 CL 6 We— TWO 0 10 15 20 25 30 35 40 45 50 55 60 Flow (gpm) Pressure Loss in 1-1/2" Resi-Riser eIieving Pressure xceeding 175 psi 10 Manual Open - Drain CIL 8 6 IA 4 0. or Flow Switch Test 0 0 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 Flow (gpm) ocked Closed for 6 lydrostatic Test 1A 5 CL 4 Pressure Loss in 2" Resi-Riser 0 15 25 35 45 55 65 75 85 95 Flow (gpm) 0 National Fire Products, LIC (800) 528-7978 tqco Ffre Protection Products Worldwide Contacts I www.tyco-fire.com RAPID RESPONSE Series LFII Residential 49 K-factor Concealed Pendent Sprinkler Flat Plate, Wet Pipe and Dry Pipe Systems General Description TYCO RAPID RESPONSE Series LFll Residential 4.91K Concealed Pendent Sprinklers (TY3596) are decorative, fast response, fusible solder sprinklers designed for use in residential occu- pancies such as homes, apartments, dormitories, and hotels. The cover plate assembly conceals the sprinkler operating components above the ceiling. The flat profile of the cover plate provides the optimum aes- thetically appealing sprinkler design. In addition, the concealed design of the Series LFll Residential Concealed Pendent Sprinklers (TY3596) provides 1/2 inch (12,7 mm) vertical adjustment. This adjustment provides a measure of flexibility when cutting fixed sprinkler drops. The Series LFII Residential Concealed Sprinklers are intended for use in the following scenarios: wet and dry pipe residential sprin- kler systems for one- and two-fam- ily dwellings and mobile homes per NFPA 13D wet and dry pipe residential sprinkler systems for residential occupancies up to and including four stories in height per NFPA 13R wet and dry pipe sprinkler systems for the residential portions of any occupancy per NFPA 13 IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. Page 1 of 6 The Series LFII Residential Concealed Pendent Sprinklers (TY3596) has been designed with heat sensitivity and water distribution characteristics proven to help in the control of residen- tial fires and to improve the chance for occupants to escape or be evacuated. The Series LFII Residential Con- cealed Pendent Sprinklers (TY3596) are shipped with a Disposable Pro- tective Cap. The Protective Cap is temporarily removed for installation, and then it can be replaced to help protect the sprinkler while the ceiling is being installed or finished. The tip of the Protective Cap can also be used to mark the center of the ceiling hole into plaster board, ceiling tiles, etc. by gently pushing the ceiling product against the Protective Cap. When the ceiling installation is complete the Pro- tective Cap is removed and the Cover Plate Assembly installed. Dry Pipe System Application The Series LFII Residential Concealed Pendent Sprinklers offers a laboratory approved option for designing dry pipe residential sprinkler systems, whereas, most residential sprinklers are labora- tory approved for wet systems only. Through extensive testing, it has been determined that the number of design sprinklers (hydraulic design area) for the Series LFII Residential Concealed Pendent Sprinklers (TY3596) need not be increased over the number of design sprinklers (hydraulic design area) as specified for wet pipe sprinkler systems, as is accustomed for density/ area sprinkler systems designed per NFPA 13. Consequently, the Series LFII Residen- tial Concealed Pendent Sprinklers offer the features of non-water filled pipe in addition to not having to increase the number of design sprinklers (hydraulic design area) for systems designed to NFPA 13, 13D,or13R. FEBRUARY 2015 NOTICE The Series LFll Residential Concealed Pendent Sprinklers (TY3596) described herein must be installed and main- tained in compliance with this docu- ment and with the applicable standards of the National Fire Protection Associa- tion (NFPA), in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the perfor- mance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Sprinkler Identification Number (SIN) TY3596 TFP442 SEALING ASSEMBLY LEVER SOLDER LINK I I I ELEMENT II II II II II II I II II II II I I I DEFLECTOR ' I (OPERATED - ----- POSITION) SPRINKLER/SUPPORT CUP ASSEMBLY I RETAINER WITH THREAD 11 - DIMPLES JECTION SPRING COVER PLATE TFP442 Page 2 of 6 BODY (1/2" NPT) CAP SADDLE - SUPPORT CUP WITH - ROLL FORMED THREADS GUIDE PIN GUIDE PIN HOUSING DEFLECTOR - THREAD INTO SUPPORT CUP UNTIL MOUNTING SURFACE IS FLUSH WITH CEILING WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 2 W-TYPE 18 SPRINKLER WRENCH S SPRINKLER WRENCHING AREA COMPRESSION SCREW wwv n ru , fl IflhIfl ASSEMBLY FIGURE 1 RAPID RESPONSE SERIES LFII RESIDENTIAL CONCEALED PENDENT SPRINKLER (TY3596 SOLDER TAB 2-1/2" DIA. (63,5 mm) 1/2 (12,7 mm) FACE OF / SPRINKLER ADJUSTMENT FITTING I - - 1-7/8±1/4" L (47,6 mm 1/8 GAP I ±6,4 mm) (3,2 mm) SPRINKLER- SUPPORT CUP / ASSEMBI OPERATE SPRINKLE COVER PLATE RETAINEI /\J 7/8"(22,2 ii 1-1/8" (28,6 DISPOSABLE ')_ _3 COVER- SPRINKLER- I J MOUNTING RETAINER SUPPORT CUP 3/16 1 SURFACE ASSEMBLY ASSEMBLY (4,8 mm) 3-3/16' DIA. _______ DEFLECTOR ______ DEFLECTOR IN (81,0 mm) TIP PROTECTIVE CAP OPERATED POSITION FIGURE 3 RAPID RESPONSE SERIES LFII RESIDENTIAL CONCEALED PENDENT SPRINKLER (TY3596) INSTALLATION DIMENSIONS/PROTECTIVE CAP/ACTIVATED DEFLECTOR TFP442 Page 3 of 6 Technical Data Approvals UL and C-UL Listed NYC Approved under MEA 44-03-E-2NSF Certified to NSF/ANSI 61 The TYCO RAPID RESPONSE Series LFII Residential Concealed Pendent Sprinklers are only Listed with the Series LFII Con- cealed Cover Plates having a factory-ap- plied finish. Cover Plates can be ordered by following the instructions in the Ordering Procedure section. Maximum Working Pressure 175 psi (12,1 bar) Discharge Cpfficient K=4.9 gpm/psi (70,6 pm/bar1 /2) Temperature Rating 160°F (71°C) Sprinkler with 139°F (59°C) Cover Plate Vertical Adjustment 1/2 inch (12,7 mm) Finishes Refer to Ordering Procedure section. Physical Characteristics Body.........................Brass Cap.........................Bronze Saddle .......................Brass Sealing Assembly.......Beryllium Nickel w/TEFLON Soldered Link Halves............Nickel Lever........................Bronze Compression Screw.............Brass Deflector...................Copper or Brass Guide Pin Housing.............Bronze Guide Pins .............Stainless Steel or Bronze Support Cup ...................Steel Cover Plate ..................Copper Retainer ......................Brass Cover Plate Ejection Spring..........Stainless Steel Operation When exposed to heat from a fire, the Cover Plate, which is normally soldered to the Support Cup at three points, falls away to expose the sprinkler assembly. At this point the Deflector supported by the Arms drops down to its operated position. The fusible link of the sprin- kler assembly is comprised of two link halves that are soldered together with a thin layer of solder. When the rated temperature is reached, the solder melts and the two link halves separate allowing the sprinkler to activate and flow water. Design Criteria TYCO RAPID RESPONSE Series LFII Residential Concealed Pendent Sprin- klers (TY3596) are UL and C-UL Listed for installation in accordance with this section. Note: When conditions exist that are outside the scope of the provided cri- teria, refer to the Residential Sprinkler Design Guide TFP490 for the manu- facturer's recommendations that may be acceptable to the authority having jurisdiction. System Types Per the UL Listing, wet pipe and dry pipe systems may be utilized. Per the C-UL Listing, only wet pipe systems may be utilized. Refer to Technical Data Sheet TFP485 about the use of residential sprinklers in residential dry pipe systems. Ceiling Types Smooth flat horizontal, or beamed, or sloped, in accordance with the 2013 Edition of NFPA 13D, 13R, or 13 as applicable. Hydraulic Design (NFPA 13D and 13R) For systems designed to NFPA 13D or NFPA 13R, the minimum required sprinkler flow rates are given in Tables A and B as a function of tem- perature rating and the maximum allowable coverage areas. The sprinkler flow rate is the minimum required discharge from each of the total number of "design sprinklers" as specified in NFPA 13D or NFPA 13R. The number of "design sprinklers" specified in NFPA 13D and 13R for wet pipe systems is to be applied when designing dry pipe systems. Hydraulic Design (NFPA 13) For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required dis- charge from each of the four sprinklers is to be the greater of the following: the flow rates given in Tables A and B as a function of temperature rat- ing and the maximum allowable cov- erage area a minimum discharge of 0.1 gpm/ft.2 over the design area comprised of the four (4) most hydraulically demanding sprinklers for actual coverage areas protected by the four (4) sprinklers The number of design sprinklers speci- fied in NFPA 13 for wet pipe systems is to be applied when designing dry pipe systems. Dry Pipe System Water Delivery When using the Series LFII Residen- tial Concealed Pendent Sprinklers (TY3596) in dry pipe sprinkler systems, the time for water delivery must not exceed 15 seconds for the most remote operating sprinkler. Obstruction to Water Distribution Sprinklers are to be located in accor- dance with the obstruction rules of NFPA 13D, 13R, and 13 as applicable for residential sprinklers as well as with the obstruction criteria described within the Technical Data Sheet TFP490. Operational Sensitivity The sprinklers are to be installed rela- tive to the ceiling mounting surface as shown in Figure 3. Sprinkler Spacing The minimum spacing between sprin- klers is 8 feet (2,4 m). The maximum spacing between sprinklers cannot exceed the length of the coverage area (Ref. Table A or B) being hydraulically calculated (e.g., maximum 12 feet for a 12 ft. x 12 ft. coverage area, or 20 feet for a 20 ft. x 20 ft. coverage area). The Series LFII must not be used in applications where the air pres- sure above the ceiling is greater than that below. Down drafts through the Support Cup could delay sprinkler operation in a fire situation. TFP442 Page 4 of 6 WET PIPE SYSTEM Maximum Minimum Flow and Residual Pressure 2,3 Ordinary Temp. Rating Minimum Coverage Area Maximum Spacing Ft. x Ft. Ft. 160°F (71°C) Deflector to Installation Spacing Flow Pressure (m x m) (m) Ceiling Type Ft. gpm psi (m) (1pm) (bar) 12x12 12 13 7.0 Smooth (3,7x3,7) (3,7) (49,2) (0,48) Ceilings 7/8 to 1-1/8 14x14 14 13 7.0 inches (4,3x4,3) (4,3) (49,2) (0,48) Beamed Ceilings per NFPA 13D or Concealed 8 (2,4) 16 x 16 (4,9x4,9) 16 (4,9) 13 (49,2) 7.0 (0,48) 13R, or 13. Installed in 18x18 18 17 12.0 beam (5,5x5,5) (5,5) (64,3) (0,83) 7/8to1-1/8 inches below 20 x 20 20 20 16.7 bottom of (6,1 x6,1) (6,1) (75,7) (1,15) beam Notes: For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. Requirement Is based on minimum flow in gpm Qpm) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design under the Design Criteria section. For NFPA 13 residential applications, the greater of 0.1 gpm/fl.' over the design area or the flow in accordance with the criteria in this table must be used. TABLE A WET PIPE SYSTEM SERIES LFII RESIDENTIAL 4.9 K-FACTOR FLAT PLATE CONCEALED PENDENT SPRINKLER (TY3596) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA DRY PIPE SYSTEM Minimum Flowand Residual Pressure 2,3 Maximum Coverage Maximum Spacing Ordinary Temp. Rating Area1 160°F (71°C) Minimum Ft x Ft Ft. Deflector to Installation Spacing Flow Pressure (rn x m) (m) Ceiling Type Ft. gpm psi (m) (1pm) (bar) 12x12 12 13 7.0 Smooth (3,7x3,7) (3,7) (49,2) (0,48) Ceilings 7/8 to 1-1/8 14 x 14 14 14 8.2 inches (4,3x4,3) (4,3) (53,0) (0,57) Beamed Ceilings per NFPA 13D or 8 16x16 16 15 94 (4,9x4,9) (4,9) (56,8) (0,65) or 13. Installed in Concealed 13R, (2,4) 18x18 18 18 13.5 beam (5,5x5,5) (5,5) (68,1) (0,93) 7/8to1-1/8 inches below 20 x 20 20 21 18.4 bottom of (6,1 x6,1) (6,1) (79,5) (1,27) beam Notes: For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. Requirement is based on minimum flow in gpm (1pm) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design under the Design Criteria section. For NFPA 13 residential applications, the greater of 0.1 gpm/ft.° over the design area or the flow in accordance with the criteria in this table must be used. TABLE B DRY PIPE SYSTEM RAPID RESPONSE SERIES LFII RESIDENTIAL 4.9 K-FACTOR FLAT PLATE CONCEALED PENDENT (TY3596) NFPA 130, 13R, AND 13 HYDRAULIC DESIGN CRITERIA TFP442 Page 5 of 6 Installation TYCO RAPID RESPONSE Series LFII Residential Concealed Pendent Sprin- klers (TY3596) must be installed in accordance with this section. General Instructions Damage to the fusible Link Assembly during installation can be avoided by handling the sprinkler by the support cup only (i.e., do not apply pressure to the fusible Link Assembly). A 1/2 inch NPT sprinkler joint should be obtained with a minimum to maximum torque of 7 to 14 lbs.-ft. (9,5 to 19,0 Nm). Higher levels of torque may distort the sprinkler inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Cover Plate / Retainer Assembly by under- or over-tightening the Sprinkler. Read- just the position of the sprinkler fitting to suit. Step 1. The sprinkler must only be installed in the pendent position and with the centerline of the sprinkler per- pendicular to the mounting surface. Step 2. Remove the Protective Cap. Step 3. With pipe thread sealant applied to the pipe threads, and using the W-Type 18 Wrench shown in Figure 2, install and tighten the Sprinkler / Support Cup Assembly into the fitting. The W-Type 18 Wrench will accept a 1/2 inch ratchet drive. Step 4. Replace the Protective Cap by pushing it upwards until it bottoms out against the Support Cup. The Protec- tive Cap helps prevent damage to the Deflector and Guide Pins during ceiling installation and/or during application of the finish coating of the ceiling. It may also be used to locate the center of the clearance hole by gently pushing the ceiling material against the center point of the Cap. Note: As long as the protective Cap remains in place, the system is consid- ered to be "Out Of Service." Step 5. After the ceiling has been completed with the 2-1/2 inch (63 mm) diameter clearance hole and in prep- aration for installing the Cover Plate Assembly, remove and discard the Pro- tective Cap, and verify that the Deflec- tor moves up and down freely. If the sprinkler has been damaged and the Deflector does not move up and down freely, replace the entire sprinkler assembly. Do not attempt to modify or repair a damaged sprinkler. Step 6. Screw on the Cover Plate Assembly until its flange comes in contact with the ceiling. Do not continue to screw on the Cover Plate Assembly such that it lifts a ceiling panel out of its normal position. If the Cover Plate Assembly cannot be engaged with the Mounting Cup or the Cover Plate Assembly cannot be engaged sufficiently to contact the ceiling, the Sprinkler Fitting must be repositioned. Care and Maintenance TYCO RAPID RESPONSE Series LFII Residential Concealed Pendent Sprin- klers (TY3596) must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system which it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. Absence of a Cover Plate may delay the sprinkler operation in a fire situation. When properly installed, there is a nominal 1/8 inch (3,2 mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 3. This air gap is necessary for proper opera- tion of the sprinkler by allowing heat flow from a fire to pass below and above the Cover Plate to help assure appropriate release of the Cover Plate in a fire situation. If the ceiling is to be repainted after the installation of the Sprinkler, care must be exercised to ensure that the new paint does not seal off any of the air gap. Factory painted Cover Plates must not be repainted. They should be replaced, if necessary, by factory painted units. Non-factory applied paint may adversely delay or prevent sprinkler operation in the event of a fire. Do not pull the Cover Plate relative to the Enclosure. Separation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modi- fied or over heated sprinklers must be replaced. Care must be exercised to avoid damage before, during, and after instal- lation. Sprinklers damaged by drop- ping, striking, wrench twist/slippage, or the like, must be replaced. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or product manufacturer with any questions. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national codes. TFP442 Page 6 of 6 Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and part number (P/N). Sprinkler Assemblies Specify: Series LFII (TY3596) 4.9K Residential Concealed Pendent Sprin- kler without Cover Plate Assembly, P/N 51-112-1-160 Cover Plate Assemblies Specify: Cover Plate Assembly with (specify) finish for the Series LFIl (TY3596) 4.9K Residential Concealed Pendent Sprinkler, PIN (specify): Ivory (RAL1 015) ...........P/N 56-202-0-135 Beige (RAL1001) ........... PIN 56-202-2-135 Pure White (RAL9010) .....P/N 56-202-3-135 Signal White •• (RAL9003) ... P/N 56-202-4-135 Grey White (RAL9002) ......P/N 56-202-5-135 Brown (RAL8028) .......... P/N 56-202-6-135 Black (RAL9005) ..........P/N 56-202-7-135 Brushed Brass............P/N 56-202-8-135 Brushed Chrome ..........P/N 56-202-9-135 Custom Paint .............P/N 56-202-X-135 * Eastern Hemisphere sales only Previously known as Bright White Note: All Custom Cover Plates are painted using Sherwin Williams Interior Latex Paint. Contact Tyco Customer Service with any questions related to custom orders. Sprinkler Wrench Specify: W-Type 18 Sprinkler Wrench, P/N 56-000-1-265 GLOBAL HEADQUARTERS 1 1400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700 Copyright © 2015 Tyco Fire Products, LP. All rights reserved. tqco TEFLON is trademark of The DuPont Corporation. Fire Protection Products uco Worldwide i Fire Protection Contacts 1wo-flom tq Products RAPID RESPONSE Series LFII Residential 49 K-factor Pendent Sprinkler Wet Pipe and Dry Pipe Systems General Description TYCO RAPID RESPONSE Series LFII Residential 4.91K Pendent and Recessed Pendent Sprinklers (TY2234) are decorative, fast response, frangi- ble bulb sprinklers designed for use in residential occupancies such as homes, apartments, dormitories, and hotels. When aesthetics and optimized flow characteristics are the major con- sideration, the Series LFII Residential Sprinklers (TY2234) should be the first choice. The Series LFII Residential Sprinklers are intended for use in the following scenarios: wet and dry pipe residential sprin- kler systems for one- and two-fam- ily dwellings and mobile homes per NFPA 13D wet and dry pipe residential sprinkler systems for residential occupancies up to and including four stories in height per NFPA 13R wet and dry pipe sprinkler systems for the residential portions of any occupancy per NFPA 13 The recessed version of the Series LFII Residential Sprinklers is intended for use in areas with finished ceilings. It employs a two-piece Style 20 Recessed Escutcheon. The Recessed Escutcheon provides 1/4 inch (6,4 mm) of recessed adjustment or up to 1/2 inch (12,7 mm) of total adjustment from the flush ceiling position. The IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 6 adjustment provided by the Recessed Escutcheon reduces the accuracy to which the pipe drops to the sprinklers must be cut. The Series LFII Residential Sprinklers have been designed with heat sensi- tivity and water distribution charac- teristics proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application The Series LFII Residential Pendent and Recessed Pendent Sprinklers offers a laboratory approved option for designing dry pipe residential sprin- kler systems, whereas, most residential sprinklers are laboratory approved for wet systems only. Through extensive testing, it has been determined that the number of design sprinklers (hydraulic design area) for the Series LFII Residential Pendent and Recessed Pendent Sprinklers (TY2234) need not be increased over the number of design sprinklers (hydraulic design area) as specified for wet pipe sprinkler systems, as is accustomed for density/ area sprinkler systems designed per NFPA 13. Consequently, the Series LFII Resi- dential Sprinklers offer the features of non-water filled pipe in addition to not having to increase the number of design sprinklers (hydraulic design area) for systems designed to NFPA 13,13D, or 13R. NOTICE The Series LFll Residential Pendent and Recessed Pendent Sprinklers (TY2234) described herein must be installed and maintained in compliance with this document and the applicable standards of the National Fire Protec- tion Association (NFPA), in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. MARCH 2015 Sprinkler Identification Number (SIN) TY2234 Technical Data Approvals UL Listed (for use with wet pipe and dry pipe sys- tems) C-UL Listed (for use only with wet pipe systems) Certified to all requirements of NSF/ANSI 61 (Refer to the Design Criteria section for de- tails on these approvals.) Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K=4.9 gpm/psi'/2 (70,6 1pm/bar"2) Temperature Rating 155°F (68°C) or 175°F (79°C) Finishes Natural Brass, Pure White, Signal White, or Chrome Plated Physical Characteristics Frame ........................Brass Button ......................Copper Sealing Assembly ......Beryllium Nickel w/TEFLON Bulb (3 mm)...................Glass Compression Screw ............Bronze Deflector .....................Bronze TFP400 2-7/8" DIA. (73,0 mm) 7/16±1/8" 1/2(12,7mm) - (11,1±3,2 mm) 2-1/4" DIA. 1/4"(6,4mm) FACE OF SPRINKLER MOUNTING FITTING PLATE T- 7-MOUNTING SURFACE 1/8" (3,2 mm) 1-3/8" (34,9 mm) CLOSURE TY2234 1-1/8" (28,6 mm) FIGURE 2 STYLE 20 RECESSED ESCUTCHEON FOR USE WITH THE RAPID RESPONSE SERIES LFII RESIDENTIAL PENDENT SPRINKLER TFP400 Page 2 of 6 7/16" (11,1 mm) 1/211 ESCUTCHEON Components: NOMINAL NPT PLATE SEATING 2-7/8" DIA.________ 1 - Frame MAKE-IN SURFACE (73,0 mm) 2 - Button 4 - Bulb 5 - Compression 2 / 2-1/4' Screw 3 - Sealing Assembly 1 ESCUTCHEON 1-5/8" 6 - Deflector* ' I. :.icdl7 (57,2 mm) ________ ______________ STYLE 20 (41,3mm) I wRENCH RECESSED * Temperature rating is 6* FLATS indicated on Deflector. CROSS SECTION PENDENT RECESSED PENDENT FIGURE 1 RAPID RESPONSE SERIES LFII RESIDENTIAL 4.9K PENDENT AND RECESSED PENDENT SPRINKLERS (TY2234) Design Criteria The TYCO RAPID RESPONSE Series LFII Residential 4.9K Pendent and Recessed Pendent Sprinklers are UL and C-UL Listed for installation in accordance with this section. Residential Sprinkler Design Guide When conditions exist that are outside the scope of the provided criteria, refer to the Residential Sprinkler Design Guide TFP490 for the manufactur- er's recommendations that may be acceptable to the local authority having jurisdiction. WRENCH RECESS / (END "A" USED FOR TY2234) FIGURE 3 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 4 W-TYPE 7 RECESSED SPRINKLER WRENCH System Types Per the UL Listing, wet pipe and dry pipe systems may be utilized. Per the C-UL Listing, only wet pipe systems may be utilized. Refer to Technical Data Sheet TFP485 for the use of residential sprinklers in residential dry pipe systems. Ceiling Types Smooth flat horizontal, or beamed, or sloped, in accordance with the 2013 Edition of NFPA 13D, 13R, or 13, as applicable. Operation The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and flow water. TFP400 Page 3 of 6 Hydraulic Design (NFPA 13D and 13R) For systems designed to NFPA 13D or NFPA 13R, the minimum required sprinkler flow rates are given in Tables A and B as a function of tem- perature rating and the maximum allowable coverage areas. The sprinkler flow rate is the minimum required discharge from each of the total number of "design sprinklers" as specified in NFPA 13D or NFPA 13R. The number of "design sprinklers" specified in NFPA 13D and 13R for wet pipe systems is to be applied when designing dry pipe systems. Hydraulic Design (NFPA 13) For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required dis- charge from each of the four sprinklers is to be the greater of the following: The flow rates given in Table A or B as a function of temperature rating and the maximum allowable coverage area. A minimum discharge of 0.1 gpm/ft2 over the "design area" comprised of the four most hydraulically demanding sprinklers for actual coverage areas protected by the four sprinklers. The number of design sprinklers speci- fied in NFPA 13 for wet pipe systems is to be applied when designing dry pipe systems. Dry Pipe System Water Delivery When using the Series LFll Residential Sprinklers (TY2234) in dry pipe sprin- kler systems, the time for water deliv- ery must not exceed 15 seconds for the most remote operating sprinkler. Obstruction to Water Distribution Sprinklers are to be located in accor- dance with the obstruction rules of NFPA 13D, 13R, and 13 as applicable for residential sprinklers as well as with the obstruction criteria described within the Technical Data Sheet TFP490. Operational Sensitivity Sprinklers are to be installed with a deflector-to-ceiling distance of 1-1/4 to 4 inches. Sprinkler Spacing The minimum spacing between sprin- klers is 8 feet (2,4 m). The maximum spacing between sprinklers cannot exceed the length of the coverage area (Table A or B) being hydraulically cal- culated (e.g., maximum 12 feet for a 12 ft. x 12 ft. coverage area, or 20 feet for a 20 ft. x 20 ft. coverage area). Installation TYCO RAPID RESPONSE Series LFII Residential 4.91K Pendent and Recessed Pendent Sprinklers must be installed in accordance with this section. General Instructions Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm). A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a min- imum-to-maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in an Escutch- eon Plate by under- or over- tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Series LFll Residential Pendent Sprinklers The Series LFll Residential Pendent Sprinklers must be installed in accor- dance with the following instructions: Step 1. Install pendent sprinklers in the pendent position with the deflector par- allel to the ceiling. Step 2. With pipe thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 3). With ref- erence to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Series LFll Residential Recessed Pendent Sprinklers The Series LFll Residential Recessed Pendent Sprinklers must be installed in accordance with the following instructions: Step A. Install recessed pendent sprin- klers in the pendent position with the deflector parallel to the ceiling. Step B. After installing the Style 20 Mounting Plate over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step C. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 4). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Step D. After the ceiling has been installed or the finish coat has been applied, slide on the Style 20 Closure over the Series LFll Residential Sprin- kler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. TFP400 Page 4 of 6 WET PIPE SYSTEM Minimum Flow and Residual Pressure (2)(3) Maximum Coverage Ordinary Temperature Rating Intermediate Temperature Rating Area (1) 155°F (68°C) 175°F (79°C) Minimum Deflector to Installation Spacing Flow Pressure Flow Pressure Ft. x Ft. Ceiling Type Ft. (m x m) gpm psi gpm Psi (m) (I/mm) (bar) (I/mm) (bar) 12x12 13 7.0 13 7.0 Smooth (3,7x3,7) (49,2) (0,48) (49,2) (0,48) Ceilings 1-1/4t0 4inches 14x14 13 7.0 13 7.0 (4,3x4,3) (49,2) (0,48) (49,2) (0,48) Beamed Recessed using Style 20 16 x 16 13 7.0 13 7.0 Ceilings per Escutcheon or 8 (4,9 x 4,9) (49,2) (0,48) (49,2) (0,48) NFPA 13D or 13R non-recessed NFPA 13D, 13R, or 13 (2,4) per 18 x 18 17 12.0 17 12.0 (5,5x5,5) (64,3) (0,83) (64,3) (0,83) 1-1/4to1-3/4 inches below bottom of 20 x 20 20 16.7 20 16.7 (6,1 x 6,1) (75,7) (1,15) (75,7) (1,15) beam. Notes: For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. Requirement is based on minimum flow in gpm Qpm) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design under the Design Criteria section. For NFPA 13 residential applications, the greater of 0.1 gpm1ft.2 over the design area or the flow in accordance with the criteria in this table must be used. TABLE A WET PIPE SYSTEM SERIES LFII RESIDENTIAL 4.9K PENDENT AND RECESSED PENDENT SPRINKLERS (TY2234) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA DRY PIPE SYSTEM Minimum Flow and Residual Pressure (2)(3) Maximum Coverage Ordinary Temperature Rating Intermediate Temperature Rating Area (1) 155°F (68°C) 175°F (79°C) Minimum Ft. x Ft. (m x m) Deflector to Ceiling Installation Type Spacing Ft. Flow Pressure Flow Pressure gpm psi gpm Psi (m) (I/mm) (bar) (I/mm) (bar) 12 x 12 13 7.0 13 7.0 Smooth (3,7x3,7) (49,2) (0,48) (49,2) (0,48) Ceilings 1-1/4 to 4 inches 14 X 14 14 8.2 14 8.2 (4,3 x 4,3) (53,0) (0,57) (53,0) (0,57) Beamed Recessed using Style 20 16 x 16 15 9.4 15 9.4 Ceilings Escutcheon or 8 (4,9 x 4,9) (56,8) (0,65) (56,8) (0,65) per NFPA 13D or13R non-recessed per NFPA 13D, 13R, or 13 (2,4) 18x18 18 13.5 18 13.5 (5,5x5,5) (68,1) (0,93) (68,1) (0,93) 11/4t013/4 inches below bottom of 20 x 20 21 18.4 21 18.4 (6,1 x 6,1) (79,5) (1,27) (79,5) (1,27) beam. Notes: For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are slated. - Requirement is based on minimum flow in gpm (1pm) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design under the Design Criteria section. For NFPA 13 residential applications, the greater of 0.1 gpm/ft.2 over the design area or the flow in accordance with the criteria in this table must be used. TABLE B DRY PIPE SYSTEM SERIES LFII RESIDENTIAL 4.9K PENDENT AND RECESSED PENDENT SPRINKLERS (TY2234) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA TFP400 Page 5 of 6 Care and Maintenance TYCO RAPID RESPONSE Series LFll Residential 4.91< Pendent and Recessed Pendent Sprinklers must be maintained and serviced in accordance with this section: Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb (Ref. Installa- tion section). The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any authorities having jurisdiction. Contact the installing con- tractor or product manufacturer with any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and part number (P/N). Sprinkler Assemblies Specify: Series LFII 4.91K Residential Pendent Sprinkler (TY2234), (specify temperature rating), with (specify) finish, P/N (specify): 155°F (68°C) Natural Brass .............. PIN 51-201-1-155 Pure White (RAL 9010)*P/N 51-201-3-155 Signal White (RAL 9003) .....P/N 51-201-4-155 Chrome Plated ............. PIN 51-201-9-155 175°F (79°C) Natural Brass..............P/N 51-201-1-175 Pure White (RAL 9010)° ......P/N 51-201-3-175 Signal White (RAL 9003) .....P/N 51-201-4-175 Chrome Plated.............P/N 51-201-9-175 Eastern Hemisphere sales only Recessed Escutcheon Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (specify*) Refer to Technical Data Sheet TFP770. Sprinkler Wrenches Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 TFP400 Page 6 of 6 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700 Copyright 02015 Tyco Fire Products, LP. All rights reserved. tqco TEFLON is trademark of the DuPont Corporation. Fire Protection Products tqca Ffre Protection Products Worldwide Contacts www.tyco-fire.com Series TY-FRB - 28, 42, 56, and 80 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright, Pen- dent, and Recessed Pendent Sprin- klers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TV- FRB Pendent Sprinkler, where applica- ble, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Escutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a A two-piece Style 20 (1/2 inch NPT) or Style 30 (3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjustment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion-resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be obtained when exposed to corrosive atmo- IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 10 spheres. Although corrosion-resistant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suit- ability of these coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level of the Series TY- FRB Pendent Sprinklers is detailed in Technical Data Sheet TFP356, and Sprinkler Guards are detailed in Tech- nical Data Sheet TFP780. NOTICE The Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright, Pendent, and Recessed Pendent Sprinklers described herein must be installed and maintained in compliance with this document and with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. OCTOBER 2013 Sprinkler Identification Number (SIN) TY1131: Upright 2.8K,1/2NPT 1Y1231: Pendent 2.8K, 1/2"NPT TY2131: Upright 4.2K, 1/2" NPT TY2231: Pendent 4.2K, 1/2" NPT TY3131: Upright 5.6K, 1/2" NPT 1Y3231: Pendent 5.6K, 1/2" NPT TY4131: Upright 8.0K, 3/4- NPT 1Y4231: Pendent 8.0K, 3/4" NPT TY4831: Upright 8.0K, 1/2" NPT TY4931: Pendent 8.0K, 1/2" NPT TFPI7I 2-3/16" (55,6 mm) (38,1 mm) STYLE 10 or 20 H— 2-7/8" (73,0 mm) DIA. —j RECESSED ESCUTCHEON RECESSED PENDENT CROSS SECTION TFPI7I Page 2 of 10 * Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector, special request. PLATE SEATING 4 - Bulb 6 - Deflector * SURFACE 7 - Bushing 7/16 (11,1 mm) NOMINAL MAKE-IN 2-3/16" (55.6 1/2 NPT** t WRENCH FLATS UPRIGHT PENDENT 2-1/4° (57,2 mm) 1-9/16" (39,7 mm) STYLE 10 or 20 RECESSED ESCUTCHEON 2-7/8" (73,0 mm) DIA. RECESSED PENDENT I' CROSS SECTION FIGURE 1 QUICK RESPONSE SERIES TY.FRB UPRIGHT (TYII3I) AND PENDENT (TY1231) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT * Temperature rating ** Pipe thread connections per 1 - Frame is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Deflector, special request. PLATE SEATING SURFACE 3 - Sealing 5 - Compression Assembly Screw 4 - Bulb 6 - Deflector* 7/16" (11 \ 1 I , mm) I NOMINAL J-71 MAKE-IN I I 2-3/16" (55.6 mm 1/2 I 1/2( NPT** t WRENCH FLATS UPRIGHT PENDENT FIGURE 2 QUICK RESPONSE SERIES TV-FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K-FACTOR, 1/2 INCH NPT * Temperature rating is indicated on Deflector. ** Pipe thread connections per ISO 7-1 can be provided on special request. 1/2" NPT* UPRIGHT 2-7/8" (73,0 mm) DIA. RECESSED PENDENT CROSS SECTION TFPI7I Page 3 of 10 1 - Frame 3 - Sealing 5 - Compression 2 - Button Assembly Screw 4 - Bulb 6 - Deflector* ESCUTCHEON PLATE SEATING SURFACE 7/16" i 11,1 mm) I MAKE-IN T(55,6 mm) JOMINAL 2-3/16" (38,1 mm) (55,6 mm) $ f WRENCH STYLE 10 or 20 FLATS RECESSED PENDENT ESCUTCHEON CROSS SECTION 2-7/8" (73,0 mm) DIA. -'- RECESSED PENDENT FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT (f3231) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT * Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE iI T(58,7 5L 1/2" gig (12,7 mm) NOMINAL _____ mm) MAKE-IN 2-1/4" 1-9/16" I .2mm/( _ $ (57 3/4 NPT** f WRENCH STYLE 30 or 40 FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 8.0 K-FACTOR, 314 INCH NPT TFPI7I Page 4 of 10 ; 7/16 (11,1 mm) MAKE-IN 23/ NOMINAL 16 (55,6 mm) 1/2' NPT** f WRENCH FLATS UPRIGHT PENDENT CEILING PLATE 1 - Frame 5 - Compression SEATING SURFACE 2 - Button Screw i 3 - Sealing 6 - Deflector * Assembly 4 - Bulb / 2-1/4 (57,2 mm) * / 1 Y 6* Temperature rating is 1-9/16° indicated on Deflector. (39,7 mm) I 5 ** Pipe thread connections perlSO7-1 can be provided on special request. CROSS SECTION FIGURE 5 QUICK RESPONSE SERIES TYFRB UPRIGHT (TY4831) AND PENDENT (TY4931) SPRINKLERS 8.0 K-FACTOR, 1/2 INCH NPT Technical Data Approvals UL and C-UL Listed FM, LPCB, and NYC Approved Refer to Table A and B for complete approval information including corrosion-resistant status. Maximum Working Pressure Refer to Table C. Discharge Coefficient K=2.8 GPM/psi1/2 (40,3 LPM/bar11 K=4.2 GPM/psi1/2 (60,5 LPM/bar1/2) K=5.6 GPM/psi"2 (80,6 LPM/barll2) K=8.0 GPM/psi1/2 (115,2 LPM/bar"2) Temperature Rating Refer to Table Aand B. Finishes Sprinkler: Refer to Table D. Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated. Physical Characteristics Frame ...................Bronze Button..............Brass/Copper Sealing Assembly.........Beryllium Nickel w/TEFLON Bulb ......................Glass Compression Screw........Bronze Deflector...........Copper/Bronze Bushing (K=2.8) ...........Bronze Operation The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright, Pen- dent, and Recessed Pendent Sprinklers are intended for fire protection sys- tems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the require- ments of FM's Loss Prevention Data Sheets). Only the Style 10, 20, 30, or 40 Recessed Escutcheon, as applica- ble, is to be used for recessed pendent installations. Installation The TYCO Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright, Pendent, and Recessed Pendent Sprinklersmust be installed in accordance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) and 3/32 inch (2,4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint shold be obtained by applying a min- imum to maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). A leak tight 3/4 inch NPT sprinkler joint should be obtained with a torque of 10 to 20 ft.- lbs. (13,4 to 26,8 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Series TY-FRB Upright and Pendent Sprinklers The Series TY-FRB Pendent and Upright Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 14). With refer- ence to Figures 1 through 5, apply the W-Type 6 Sprinkler Wrench to the sprin- kler wrench flats. Series TY-FRB Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 10, 20, 30, or 40 Mounting Plate, as applica- ble, over the sprinkler threads and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkl& into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure TFPI7I Page 5 of 10 SPRINKLER FINISH (See Note 5) K FACTOR TYPE TEMPERATURE BULB LIQUID COLOR NATURAL BRASS I CHROME PLATED I SIGNAL*** f WHITE 2.8 1/2" NPT PENDENT (TY1231) and UPRIGHT (TY1131) 135°F (57°C) Orange 1, 2, 3, 4 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue RECESSED PENDENT (TY1231)° 135°F (57°C) Orange 1,2,4 155°F (68°C) Red Figure 6 175°F (79°C) Yellow 200°F (93°C) Green RECESSED PENDENT (TY1231)** Figure 7 135°F (57°C) Orange 155°F (68°C) Red 175°F (79°C) Yellow 200°F(93°C) Green 4.2 1/2" NPT PENDENT (TY2231) and UPRIGHT (TY2131) 135°F (57°C) Orange 1,2 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286-F (141-C) Blue RECESSED (TY2231)* Figure 8 135°F (57°C) Orange PENDENT 155°F (68°C) Red 175°F (79°C) Yellow 200°F(93°C) Green RECESSED PENDENT (TY2231)** Figure 9 135°F (57°C) Orange 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green NOTES: Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the City of New York under MEA 354-01-E. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20(1/2" NPT) or Style 30(3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS FOR 2.8 AND 4.2 K-FACTOR SPRINKLERS 15). With reference to Figures 1 to 4, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Step C. After ceiling installation and finishing, slide on the Style 10, 20, 30, or 40 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. TFPI7I Page 6 of 10 SPRINKLER FINISH (See Note 8) K FACTOR TYPE TEMPERATURE BULB LIQUID COLOR NATURAL BRASS I CHROME PLATED I SIGNAL*** WHITE LEAD COATED 5.6 1/2" NPT PENDENT (TY3231) and UPRIGHT (TY3131) 135°F (57°C) Orange 1, 2, 3, 4, 5, 6, 7 Blue 1, 2, 3, 5 (68-C) -155-F Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) RECESSED PENDENT (TY3231)* Figure 10 135°F (57°C) Orange 1, 2, 4, 5 Blue N/A 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) RECESSED PENDENT (TY3231)** Figure 11 135°F (57°C) Orange 1, 2, 3, 4, 5 Blue N/A 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) 8.0 3/4" NPT PENDENT (TY4231) and UPRIGHT (TY4131) 135°F (57°C) Orange 1, 2, 3, 4, 5, 6, 7 Blue 1, 2, 5 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) RECESSED PENDENT (TY4231)° Figure 12 135°F (57°C) Orange 1, 2, 5 Blue N/A 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) RECESSED PENDENT (TY4231)** Figure 13 135°F (57°C) Orange 1, 2, 3, 5 Blue N/A 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) 8.0 1/2" NPT PENDENT (TY4931) and UPRIGHT (TY4831) 135°F (57°C) Orange 1, 2, 4, 5, 6 Blue 1, 2, 5 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) NOTES: Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers. However, LPCB does not rate the thermal sensitivity of recessed sprinklers. Approved by the City of New York under MEA 354-01-E. VdS Approved (For details, contact Tyco Fire Suppression & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53.428-3377.) Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. Where Polyester Coated and Lead-Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. Where Lead-Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion-Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20(1/2" NPT) or Style 30(3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS FOR 5.6 AND 8.0 K-FACTOR SPRINKLERS TFPI7I Page 7 of 10 SPRINKLER FINISH K TYPE NATURAL I CHROME I SIGNAL LEAD FACTOR BRASS PLATED WHITE COATED PENDENT (TY1231) and 2.8 UPRIGHT (TYII3I) 1/2" NPT 175 PSI (12,1 BAR) N/A RECESSED PENDENT (TY1231) PENDENT (TY2231) and 4.2 UPRIGHT (TY2131) 1/2" NPT 175 PSI (12,1 BAR) N/A RECESSED PENDENT (TY2231) PENDENT (TY3231) 175 PSI 5.6 and UPRIGHT (TY3131) 250 PSI (17,2 BAR) (12,1 BAR) 1/2" NPT OR 175 PSI (12,1 BAR) RECESSED (SEE NOTE 1) N/A PENDENT (TY3231) PENDENT (TY4231) 175 PSI 8.0 and UPRIGHT (TY4131) (12,1 BAR) 3/4" NPT 175 PSI (12,1 BAR) RECESSED N/A PENDENT (TY4231) 8.0 PENDENT (TY4931) 175 PSI 1/2" NPT and 175 PSI (12,1 BAR) (12,1 BAR) UPRIGHT (TY4831) NOTES: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL); and, the Approval by the City of New York. Care and Maintenance The TYCO Series TY-FRB must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to TABLE C MAXIMUM WORKING PRESSURE corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any other authorities hav- ing jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Care must be exercised to avoid dam- age to the sprinklers -before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Initial and frequent visual inspections of random samples are recommended for corrosion-resistant sprinklers to verify the integrity of the corrosion-resistant material of construction. Thereafter, annual inspections per NFPA 25 should suffice. Inspections of corrosion-resistant sprinklers are recommended at close range, instead of from the floor level per NFPA. Inspection at close range can better determine the exact sprin- kler condition and the long-term integ- rity of the corrosion-resistant material, which can be affected by the corrosive conditions present. TFPI7I Page 8 of 10 2-7/8" DIA. 5/8±1/4 (73,0 mm) I 3/4(19,1 mm) (15 9±6,4 mm) 2-1/4" DIA. 1/4" (6,4 mm) 7' PLATE FACE OF mm) MOUNTING SPRINKLER FITTING 1/8 11 i-I I I (3,2 mm) • MOUNTING SURFACE CLOSURE SERIES 1-5/16" (33,3 mm)f TY-FRB 13/16" (20,6 mm) FIGURE 6 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. I..' 5/8±1/4" (73,0 mm) I 3/4" (19,1 mm) (15,9±6,4 mm) 2-1/4' DIA. I 1/4(6,4 mm) / FACE OF (572 mm) MOUNTING SPRINKLER PLATE FITTING 1/8" (3,2 mm) MOUNTING 1 SURFACE CLOSURE SERIES 1-1/4" (31,8 mm) TY-FRB 3/4"(19,1 mm) FIGURE 8 SERIES 7Y-FRB RECESSED PENDENT WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. 1/2±1/8" (73,0 mm) I 1/2" (12,7 mm) (12,7±3,2 mm) 2-1/4" DIA. 1/4"(6,4 mm) I / FACE OF [57.2 mm) MOUNTING SPRINKLER PLATE FITTING 1/8" I (3,2 mm) I SURFACE // (33,3 mi "' MOUNTING CLOSURE SERIES TV-FRB 1-1/16" (27,0 mm) FIGURE 7 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT 2-7/8' DIA. 1/2±1/8" (73,0 mm) I 1/2" (12,7 mm) (12,7±3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm) I SPRINKLER FITTING PLATE I / FACE OF 1572 mm ? MOUNTING I 1/8" (3,2 mm) I $ MOUNTING f $ SURFACE SERIES 1-1/4" (31,8 mm) CLOSURE 1YFRB 1"(25,4 mm) FIGURE 9 SERIES TY-FRB RECESSED PENDENT WITH 7W0-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT 1/2±1/8" (12,7±3,2 mm) FACE OF SPRINKLER FITTING T-7-- MOUNTING SURFACE CLOSURE 2-7/8' DIA. (73,0 mm) 1/2" (12,7 mm) I 2-1/4" DIA. 1/4"(6,4mm) I (57,2 mm) MOUNTING I _- PLATE I ~rau_ 1/8" (3,2 mm) I t 1-1/4" (31,8 mm) 1" (25,4 mm) FIGURE 11 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. 1/2±1/8" (73,0 mm) 1/2" (12,7 mm) I (12,7±3,2 mm) 2-1/4" DIA. I 1/4"(6,4 mm) / FACE OF (57,2 mm) MOUNTING I SPRINKLE 1/8" (3,2 mm) I ER PLATE \4 MOUNTING t SURFACE CLOSURE SERIES 1-5/16" (33,3 mm), TY-FRB 1-1/16" (27,0 mm) FIGURE 13 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON ao K-FACTOR, 314 INCH NPT TFPI7I Page 9 of 10 MOUNTING SURFACE CLOSURE SER 1-1/4" (31,8 mm) 3/4(19,1 mm) FIGURE 10 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. 5/8±1/4" (73,0 mm) 3/4(19,1 mm) (15,9±6,4 mm) 2-1/4" DIA. 1/4" (6,4 mm) (57,2 mm) FACE OF I I MOUNTING SPRINKLER L,- .) - PLATE FITTING I I Il 1/8' I I (3,2 mm) MOUNTING / I I SURFACE / / I CLOSURE SERIES 1-5/16" (33,3 mm) TY-FRB 13/16" (20,6 mm) FIGURE 12 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 314 INCH NPT 5/8±1/4" (15,9±6,4 mm) FACE OF SPRINKLER FITTING 2-7/8" DIA. I.' (73,0 mm) 3/4"(19,1 mm) I 2-1/4" DIA 1/4"6,4mm) . MOUNTING PLATE 1/8" - (3,2 mm) WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B" USED FOR 3/4" NPT MODELS) FIGURE 14 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 15 W- TYPE 7 RECESSED SPRINKLER WRENCH —I— NATURAL BRASS PURE WHITE (RAL9O1O)* SIGNAL WHITE (RAL9003) JET BLACK (RAL9005)** 7 I LEAD COATED I 9 I CHROME PLATED I * Eastern Hemisphere sales only. ** Available in only 2.8K, 4.2K, and 8.0K, 155°F (68°C) and 200°F (93°C); requires lead time to manufacture. TFPI7I Page 10 of 10 P/N 57- XXX- X- XXX SIN FINISH SPRINKLER TEMPERATURE RATINGS 135 135-F (57-C) 155 155-F (68-C) 175 175-F (79-C) 200 200°F(93°C) r286 286°F (141°C) 330 2.8K UPRIGHT (1/2"NPT) TY1131 331 2.8K PENDENT (1/2"NPT) TY1231 340 4.2K UPRIGHT (1/2"NPT) TY2131 341 4.2K PENDENT (1/2"NPT) TY2231 370 5.6K UPRIGHT (1/2"NPT) TY3131 371 5.6K PENDENT (1/2"NPT) TY3231 390 8.0K UPRIGHT (3/4"NPT) TY4131 391 8.0K PENDENT (3/4"NPT) TY4231 360 8.0K UPRIGHT (1/2"NPT) TY4831* 361 8.0K PENDENT (1/2"NPT) TY4931* TABLED SERIES 7Y-FRB PENDENT AND UPRIGHT SPRINKLERS PART NUMBER SELECTION Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB (Specify SIN), (specify K-factor), (specify Pendent or Upright) Sprinkler (specify) tempera- ture rating, (specify) finish or coating, P/N (specify from Table D) Recessed Escutcheon: Specify: Style (10, 20, 30, or 40) Recessed Escutcheon with (specify*) finish, P/N (specify*) Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 * Refer to Technical Data Sheet TFP770 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700 Copyright © 2013 Tyco Fire Products, LP. All rights reserved. tqco TEFLON is trademark of The DuPont Corporation. Fire Protection Products ZURN Model 950XL WILKINS Double Check Valve Assembly Application Designed for installation on water lines to protect against both backsiphonage and backpressure of polluted water into the potable water supply. Assembly shall provide protection where a potential health hazard does not exist. Standards Compliance (All sizes approved horizontal. Vertical approvals as listed below.) ASSE® Listed 1015 (vertical 3/4", 1 1/4", 1 1/2" & 2") IAPMO® Listed (vertical 1 1/4"-2") GSA® Listed (vertical 3/4", 1 1/4", 1 1/2" & 2") AWWA Compliant C510 (vertical 3/4") UL® Classified (less shut-off valves only) C-UL® Classified (less shut-off valves only) Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern Cali- fornia (vertical 3/4") City of Los Angeles Approved (vertical 1-1/4-2") NYC MEA 426-89-M VOL 3 Materials Main valve body Cast Bronze ASTM B 584 Access covers Cast Bronze ASTM B 584 Internals Stainless Steel, 300 Series Elastomers Silicone (FDA approved) Buna Nitrite (FDA approved) Polymers NoryITM, NSF Listed Springs Stainless steel, 300 series Features Sizes: 3/4", 1", 11/2", 2" Maximum working water pressure 175 PSI Maximum working water temperature 180°F Hydrostatic test pressure 350 PSI End connections Threaded ANSI 81.20.1 Options (Suffixes can be combined) O - with full port QT ball valves (standard) 0 L - less ball valves o U - with union ball valves O S - with bronze "V' type strainer o TCU - with test cocks "vertical" up fl V - with union swivel elbows (3/4" & 1") 0 OSY - with OS & V gate valves O FDC - with fire hydrant connection (2" only) 0 FT - with integral male 450 flare SAE test fitting o PF - with Z_BiteTM push fit connections* (1/2"-1 "only) 0 PR - with ZPressTM press fit connections* *Fittings ship in box with valve and must be threaded into valve by hand on site. Accessories Repair kit (rubber only) Thermal expansion tank (Model XT) QT-SET Quick Test Fitting Set Dimensions & Weights (do not include pkg.) DIMENSIONS (a proximate) WEIGHT MODEL A UNION D LESSBALL LESS WITH SIZE A BALL L, VALVES C D E F G BALL BALL VALVES VALVES VALVES mm —in. in. mm in. I mm in. Imm in. mm in. mm in. I mm in. I mm in. mmblbs.j 3/4 20 Ill1/4 286 12 1/2 318 7 1178 11/2 38 3 76 31/2 89 3 76 15 3811 5 2.3 7 3.2 1 25 1121/4 311113 7/8 353 7 178 11/2 38 3 76 31/2 89 3 76 173/4 451 8 3.6 12 151/2 419 181/2 470 109/16 268 2 51 31/2 89 41/2 114 41/2 114 211/2 546 16 7.3 22 10 11/2 40 171/8435 1181/41460 191/8 486 109/16 268 2 51 31/2 89 41/2 114 41/2 114 223/4 578 16 7.3 22 10 2 50 20 508 109/16 268 2 51 31/2189 41/2 114141/2 114 251/8 638 16 7.3 28112.7 *Size 1-1/4" Discontinued Zurn Industries, LLC I Wilkins 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 In Canada I Zurn Industries Limited 3544 Nashua Drive, Mississauga, Ontario L4V 1 L2 Ph. 905-405-8272, Fax 905-405-1292 Rev. D Date: 4/15 Document No. BF-950XL Product No. Model 950XL www.zurncom I Page 1 of 2 Flow Characteristics 0 Rated flow (established by appenval agencies) MODEL 950XL 3/4",1",11/4",11/2" & 2" (STANDARD & METRIC) FLOW RATES (IFs) .lc — ip_ Ic I [III 11' •.Z.I. J. FLOW RATES (GPM) Typical Installation Local codes shall govern installation requirements. To be installed in accordance with the manufacturer's instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a mini- mum of 12" (305mm) and a maximum of 30" (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. Capacity thruSchedule 40 Pipe Pipe size 5 ft/sec 7.5 ft/sec 10 ft/sec 15 ft/sec 1/8" 1 1 2 3 1/4" 2 2 3 5 3/8" 3 4 6 9 1/2 5 1 7 9 14 3/4" 8 12 17 25 13 20 27 40 11/4" 23 35 47 70 11/2" 32 48 63 95 52 78 105 167 PROTECTIVE ENCLOSURE 1? MIN. 30' MAX. DIRECTION OF FLOW OUTDOOR INSTALLATION 1ZAX 'MIN p •i: DIRECTION OF FLOW INDOOR INSTALLATION Specifications The Double Check Valve Backflow Preventer shall be ASSE® Listed 1015 approved, and supplied with full port ball, valves. The main body and access covers shall be bronze (ASTM B 584), the seat rings and all internal polymers shall be NSF® Listed NorylTM and the seat disc elastomers shall be silicone. The first and second checks shall be accessible for maintenance with- out removing the device from the line. The Double Check Valve Backflow Preventer shall be a ZURN WILKINS Model 950XL. Zurn Industries, LLC I Wilkins 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 In Canada I Zurn Industries Limited 3544 Nashua Drive, Mississauga, Ontario L4V 1L2 Ph. 905-405-8272, Fax 905-405-1292 www.zurn.com Page 2 of 2