Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
3111 CADENCIA ST; ; FPR2018-0235
PERMIT REPORT tyctyi of Carlsbad Print Date: 09/07/2023 Job Address: 3111 CADENCIA ST, CARLSBAD, CA 92009 Permit Type: FIRE-Construction Residential Work Class: Parcel #: 2231305000 Track #: Valuation: $508,881.67 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check U: Plan Check U: Permit No: FPR2018-0235 Status: Closed - Finaled Single Family Fire Sprinkl Applied: 11/21/2018 Issued: 12/05/2018 DEV2017-0240 Finaled Close Out: 09/26/2019 Final Inspection: INSPECTOR: Fieri, Dominic Salcedo, Felix Project Title: LOT 213 LA COSTA AVE Description: LOT 213 LA COSTA - NEW SFD SPRINKLER SYSTEM (35 HEADS) FPContractor: INNOVATIVE FIRE PROTECTION INC 8779 COTTONWOOD AVE, U STE 101 SANTEE, CA 92071-4457 (619) 593-8200 FEE AMOUNT FIRE NFPA 13D Single Family System (lnsp/Bldg) $125.00 FIRE NFPA 13D Single Family System (Plan Review) $246.00 Total Fees: $371.00 Total Payments To Date: $371.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov HYDRAULIC CALCULATIONS for Job Information Project Name: C7236 L0T213 - LA COSTA Contract No.: C -16 711148 City: CARLSBAD, CA 92009 Project Location: 3111 CADENCIA ST. Date: 11/19/2018 Contractor Information Name of Contractor: INNOVATIVE FIRE PROTECT, INC. Address: 8779 COTTONWOOD AVE.,STE. 101 City: SANTEE, CA 92071 Phone Number: 619-593-8200 E-mail: alex@ifpinc.net Name of Designer: ALEJANDRO Authority Having Jurisdiction: CARLSDBAD FIRE AUTHORITY Design 000 Remote Area Name 1 Q Remote Area Location M BATH p Q C1 0 Occupancy Classification Ce)' • Density (gpm/ft2) 0.053 w U) >-U) Area of Application (ft2) 400 Ui Coverage per Sprinkler (ft 400 z C'1 Number of Calculated Sprinklers I In-Rack a. U) In-Rack Demand (gpm) 0 I— I.L. Special Heads U) <uJ 0 Hose Streams (gpm) 5 __ z < 9 Total Water Required (incl. Hose Streams) (gpm) 26 CO 0 Required Pressure at Source (psi) 58.1 CNI U 0 Type of System Wet w Volume -Entire System (gal) 11.9 gal LL n a Water Supply Information Date 11/19/2218 Location SITE Source Notes File: Y:\ENGlNEERlNG3A.Project FilesC7236 LOT2I3 - LA COSTAC7236 L0T213 - LA COSTA.dwg Date 11/19/2018 Copyright© 2002-2012 Tyco Fire Protection Products Page 1 Supply 1:1 Flow (gpm) Pressure (psi) 0 117 500 112 Supply Analysis Job: C7236 L0T213 - LA COSTA Hydraulic Analysis for: I Calculation Info Calculation Mode Demand Hydraulic Model Hazen-Williams Fluid Name Water 0 60F (15.6C) Fluid Weight, (lb/ft3) N/A for Hazen-Williams calculation. Fluid Dynamic Viscosity, (lb•s/ft2) N/A for Hazen-Williams calculation. Water Supply Parameters I Node at Source I Static Pressure I Residual Pressure I Flow I Available Pressure I Total Demand I I Required Pressure (psi) I (psi) I (gpm) I (psi) I (gpm) I I (psi) I 1 117 112 500 117 26 58.1 Hoses Inside Hose Flow! Standpipe Demand (gpm) 5 Outside Hose Flow (gpm) 0 Additional Outside Hose Flow (gpm) Other (custom defined) Hose Flow (gpm) 0 Total Hose Flow (gpm) 5 Sprinklers Ovehead Sprinkler Flow (gpm) 21 InRack Sprinkler Flow (gpm) 0 Other (custom defined) Sprinkler Flow (gpm) 0 Total Sprinkler Flow (gpm) 21 Other Required Margin of Safety (psi) 0 -Pressure (psi) 58.1 - Flow (gpm) 26 Demand w/o System Pump(s) N/A File: V:\ENGINEERING13A.Project Files\C7236 L0T213 - LA COSTA\C7236 L0T213 - LA COSTA.dwg Date 11/19/2018 Copyright© 2002-2012 Tyco Fire Protection Products Page 2 Job: C7236 L0T213 - LA COSTA File: Y:ENGlNEERlNG\3A.Project FilesC7236 L0T213 - LA COSTAC7236 L0T213 - LA COSTA.dwg Date 11/19/2018 Copyright© 2002-2012 Tyco Fire Protection Products Page 3 Job: C7236 L0T213 - LA COSTA Hydraulic Analysis for: I Graph Labels Label Description Values Flow (gpm) Pressure (psi) SI Supply point #1 -Static 0 117 S2 Supply point #2 - Residual 500 112 Dl Elevation Pressure 0 6.6 D2 System Demand 26 58.1 Curve Intersections & Safety Margins Curve Name Intersection I Safety Margin Pressure (psi) I Flow (gpm) I Pressure (psi) I @ Flow (gpm) Supply 117 39.3 58.9 26 Open Heads Required Calculated Head Ref. Head Type Coverage K-Factor Density Flow Pressure Density Flow Pressure (ft2) (gpm/psi'/2) (gpm/ft2) (gpm) (psi) (gpm/ft2) (gpm) (psi) Ti Overhead 400 4.9 0.05 20 18.4 0.053 21 18.4 Sprinkler File: Y:\ENGINEERING13A.Project Files\C7236 LOT213 - LA COSTA\C7236 L0T213 - LA COSTA.dwg Date 11/19/2018 Copyright@ 2002-2012 Tyco Fire Protection Products Page 4 NOTES Ti 68 10 11 4.9 21 21 1 1.101 lx(BM.90)=5 1 5 6 150 0.0743 18.4 -0.4 0.4 68 25 11 11 0 21 .75 0.874 ix(BM.Tee-Br)=3 1.67 3 4.67 150 0.2287 18.4 0 1.1 25 21 ii 11 -9.1 12 .75 0.874 3x(BM.Tee-Run)=3 lx(BM.90)=4 32.35 7 39.35 150 0.0805 19.5 0 3.2 21 13 11 11 0 12 .75 0.874 5x(BM.Tee-Run)=5 27.5 5 32.5 150 0.0805 22.6 0 2.6 13 10 11 11 9.1 21 .75 0.874 2x(BM.Tee-Run)=2 lx(BM.90)=4 16.64 6 22.64 150 0.2287 25.3 0 5.2 10 08-0 ii 5.75 0 21 1 1.101 lx(coupling)=1.91 lx(BM.90)=5 10.44 6.91 17.35 150 0.0743 30.4 2.3 1.3 08-0 08-1 5.75 5.25 0 21 1 0 0.5 0 0.5 0 8.601 34 0.2 4.3 RESI 08-I 07 5.25 3 0 21 1 1.101 lx(coupling)=1.91 2.25 1.91 4.16 150 0.0743 38.5 1 0.3 07 01 3 2 0 21 1 1.025 1 0 1 150 0.1053 39.8 0.4 0.1 01 03 2 -1 5 26 1 1.025 lx(coupling)=1.35 lx(us.90)=2.7 4 4.05 8.05 150 0.1563 40.3 1.3 1.3 03 06-0 -1 -1 0 26 1.5 1.598 lx(coupling)=1.46 2x(BM.90)=16 34.7 17.46 52.15 150 0.018 42.9 0 0.9 06-0 06-I -1 -i 0 26 1 0 0.5 0 0.5 0 8 43.8 0 4 1 INCH WM 06-1 1 -1 -5.2 0 26 1 0.995 46.57 0 46.57 150 0.1806 47.8 1.8 8.4 1 58.1 Path No: 2 G5 2 5 1 lx(us.Tee-Br)=6.75 0.5 150 40.3 01 2 5 1 1.025 6.75 0.0074 0 7.25 0.1 01 40.3 File: Y:ENGINEERlNG3A.Project FiIesC7236 L0T213 - LA COSTA\C7236 L0T213 - LA COSTA.dwg Date 11/19/2018 Copyright© 2002-2012 Tyco Fire Protection Products Page 5 Job: C7236 L01213 - LA COSTA Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psl'h) Wpm) (in) (ft) (ft) (psi) (psi) Path No: 3 25 0 .75 12x(BM.Tee-Run)=12 99.33 150 19.5 13 111 11 1 9.1 0.874 3x(BM.Tee-Br)=9 21 0.0481 0 120.33 5.8 13 25.3 * Pressures are balanced to a high degree of accuracy. Values may vary by 0.1 psi due to display rounding. * Maximum Velocity of 11.24 ft/s occurs in the following pipe(s): (25-68), (10-13) *** Device pressure loss (gain in the case of pumps) is calculated from the device's curve. If the device curve is printed with this report, it will appear below. The length of the device as shown in the table above comes from the CAD drawing. The friction loss per unit of length is calculated based upon the length and the curve-based loss/gain value. Internal ID and C Factor values are irrelevant as the device is not represented as an addition to any pipe, but is an individual item whose loss/gain is based solely on the curve data. File: Y:\ENGINEERING\3A.Project FilesC7236 L0T213 - LA COSTA\C7236 L0T213 - LA COSTA.dwg Date 11/19/2018 Copyright© 2002-2012 Tyco Fire Protection Products Page 6 Job: C7236 L0T213-LA COSTA Device Graphs Pressure vs. Flow Function Design Area: 1; Supply Ref.: 1; Supply Name:1 30.. 20 - 10 - 00 go- go- 70- 0' 50 - 40,• - 30 - ____________ --..-----.-- --.----,-.--.-.-----.--- --,.-------.-.-----.-.-- - 20 - 10 - Flow, gpm Pressure Loss Function Design Area: 1; Valve Ref.: 112 (1 INCH WM, Size = 1): Inlet Node: 064: Outlet Node: 06-0 9 - 9 0 2 g Flow, gpm File: Y:\ENGINEERING\3A.Project Files\C7236 L0T213 - LA COSTA\C7236 L0T213 - LA COSTA.dwg Date 11/19/2018 Copyright© 2002-2012 Tyco Fire Protection Products Page 7 Job: C7236 L0T213 - LA COSTA Device Graphs Pressure Loss Function Design Area: 1; Valve Ref.: 113 (RESI, Size = 1); Inlet Node: 084; Outlet Node: 08-0 - = 2 2 Flow, gpm File: Y:\ENG1NEER1NGt3A.Project Files\C7236 L0T213 - LA COSTAC7236 LOT2I3 - LA COSTA.dwg Date 11/19/2018 Copyright 0 2002-2012 Tyco Fire Protection Products Page 8 '7., 16.7 '5:7 14.7 '3:7 12.7 II.? V., 0. 10 :: 7.7 6.7 5.1 4.7 3.7 2.1 I .7 0.1 HYDRAULIC CALCULATIONS for Job Information Project Name: C7236 L01213 - LA COSTA Contract No.: C -16 711148 City: CARLSBAD, CA 92009 Project Location: 3111 CADENCIA ST. Date: 11/19/2018 Contractor Information Name of Contractor: INNOVATIVE FIRE PROTECT, INC. Address: 8779 COTTONWOOD AVE.,STE. 101 City: SANTEE, CA 92071 Phone Number: 619-593-8200 E-mail: alex@ifpinc.net Name of Designer: ALEJANDRO Authority Having Jurisdiction: CARLSDBAD FIRE AUTHORITY Design Remote Area Name 2 Remote Area Location 1V CAVERN Occupancy Classification Density (gpm/ft2) 0.051 Area of Application (ft2) 512 Coverage per Sprinkler (ft2) 256 Number of Calculated Sprinklers 2 In-Rack Demand (gpm) 0 Special Heads Hose Streams (gpm) 5 Total Water Required (incl. Hose Streams) (gpm) 31.5 Required Pressure at Source (psi) 58.5 Type of System Wet Volume - Entire System (gal) 12.1 gal Water Supply Information Date 11/19/2218 Location SITE 1 Source Notes File: Y:\ENGINEERING\3A.Project Files\C7236 LOT2I3 - LA COSTA\C7236 L0T213 - LA COSTA.dwg Date 11/19/2018 Copyright ©2002-2012 Tyco Fire Protection Products Page 9 Job: C7236 L0T213 - LA COSTA Hydraulic Analysis for: 2 Calculation Info Calculation Mode Hydraulic Model Fluid Name Fluid Weight, (lb/ft3) Fluid Dynamic Viscosity, (lb.s/ft2) Water Supply Parameters Supply 1: 1 Supply Analysis Demand Hazen-Williams Water © 60F (15.6C) N/A for Hazen-Williams calculation. N/A for Hazen-Williams calculation. Flow (gpm) Pressure (psi) 0 117 500 112 I Node at Source I Static Pressure I Residual Pressure I Available I Pressure Total Demand I Required Pressure (psi) I (psi) (psi) (gpm) (psi) 1 117 112 500 117 31.5 58.5 Hoses Inside Hose Flow! Standpipe Demand (gpm) 5 Outside Hose Flow .(gpm) 0 Additional Outside Hose Flow (gpm) Other (custom defined) Hose Flow (gpm) 0 Total Hose Flow (gpm) 5 Sprinklers Ovehead Sprinkler Flow (gpm) 26.5 InRack Sprinkler Flow (gpm) 0 Other (custom defined) Sprinkler Flow (gpm) 0 Total Sprinkler Flow (gpm) 26.5 Other Required Margin of Safety (psi) 0 1 - Pressure (psi) 58.5 I -Flow(gpm) 31.5 Demand w/o System Pump(s) N/A File: Y:ENGlNEERlNG3A.Project FilesC7236 LOT213 - LA COSTA\C7236 L0T213 - LA COSTA.dwg Date 11/19/2018 Copyright© 2002-2012 Tyco Fire Protection Products Page 10 Job: C7236 LOT 213 - LA COSTA File: Y:ENGlNEERlNG3A.Project Files\C7236 L0T213 - LA COSTAC7236 L0T213 - LA COSTA.dwg Date 11/19/2018 Copynght©2002-2012 Tyco Fire Protection Products Page 11 Job: C7236 L01213 - LA COSTA Hydraulic Analysis for: 2 Graph Labels Label Description Values Flow (gpm) Pressure (psi) SI Supply point #1 -Static 0 117 S2 Supply point #2 - Residual 500 112 DI Elevation Pressure 0 6.6 D2 System Demand 31.5 58.5 Curve Intersections & Safety Margins Curve Name Intersection I Safety Margin I Pressure (psi) I Flow (gpm) I Pressure (psi) I © Flow (gpm) Supply 116.9 47.4 58.5 31.5 Open Heads Required Calculated Head Ref. Head Type Coverage K-Factor Density Flow Pressure Density Flow Pressure (ft2) (gpm/psi1/2) (gpm/ft2) (gpm) (psi) (gpm/ft2) (gpm) (psi) Si Overhead 256 4.9 0.05 12.8 7 0.053 13.6 7.7 Sprinkler S2 Overhead Sprinkler 256 4.9 0.05 12.8 7 0.051 13 7 File: Y:\ENGlNEERING3A.Project Files\C7236 L01213 - LA COSTA\C7236 L0T213 - LA COSTA.dwg Date 11/19/2018 Copyright ©2002-2012 Tyco Fire Protection Products Page 12 Job: C7236 L0T213 - LA COSTA Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES I frict (Pf) (ft) (gpm/ps1½) Wpm) (in) (It) (It) (psi) (psi) Path No: I S2 10 4.9 13 1 1x(BM.Tee-Br)=5 1 150 7 29 11 13 1.101 5 0.0304 -0.4 6 0.2 29 11 0 .75 1x(BM.Tee-Run)=1 6.24 150 6.7 28 11 13 0.874 1 0.0935 0 7.24 10.7 28 11 -0.1 .75 10x(BM.Tee-Run)=10 79.59 150 7.4 13 11 12.8 0.874 3x(BM.Tee-Br)=9 19 0.0918 0 98.59 9.1 13 11 13.7 .75 2x(BM.Tee-Run)=2 16.64 150 16.5 10 11 26.5 0.874 lx(BM.90)=4 6 0.352 0 22.64 8 10 11 0 1 lx(coupling)=1.91 10.44 150 24.4 08-0 5.75 26.5 1.101 lx(BM.90)=5 6.91 0.1143 2.3 17.35 2 08-0 5.75 0 1 0.5 0 28.7 RESI 08-1 5.25 26.5 0 0 10.5197 0.2 0.5 5.3 08-I 5.25 0 1 lx(coupling)=1.91 2.25 150 34.2 07 3 26.5 1.101 1.91 0.1143 1 4.16 0.5 07 3 0 1 1 150 35.6 01 2 26.5 1.025 0 0.162 0.4 1 0.2 01 2 5 1 lx(coupling)=1.35 4 150 36.2 03 -1 31.5 1.025 lx(us.90)=2.7 4.05 0.223 1.3 8.05 1.8 03 -1 0 1.5 lx(coupling)=1.46 34.7 150 39.3 06-0 -1 31.5 1.598 2x(BM.90)=16 17.46 0.0257 0 52.15 1.3 06-0 -1 0 1 0.5 0 40.7 1 INCH WM 06-I -1 31.5 0 0 8 0 0.5 4 06-1 -1 - 0 1 46.57 150 44.7 1 -5.2 31.5 0.995 0 0.2577 1.8 46.57 12 1 58.5 Path No: 2 Si 10 4.9 13.6 1 1x(BM.Tee-Br)=5 1 150 7.7 27 ii 13.6 1.101 5 0.033 -0.4 6 0.2 27 11 0.1 .75 10x(BM.Tee-Run)=10 73.58 150 7.4 13 11 13.7 0.874 lx(BM.90)=4 14 0.1033 0 87.581 19.1 13 16.5 File: Y:\ENGINEERING13A.Project Files\C7236 L0T213 - LA COSTA\C7236 L0T213 - LA COSTA.dwg Date 11/19/2018 Copyright @2002-2012 Tyco Fire Protection Products Page 13 Job: C7236 L0T213 - LA COSTA Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (P0 (ft) (gpm/psi'/z) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 3 G5 2 5 1 1x(us.Tee-Br)=6.75 0.5 150 36.2 01 2 5 1 1.025 6.75 0.0074 0 1 7.25 0.1 01 36.2 Path No: 4 28 11 0 .75 1x(BM.Tee-Run)=1 6.01 150 7.4 27 11 0.1 0.874 1 0.0000 0 1 7.01 0 27 7.4 * Pressures are balanced to a high degree of accuracy. Values may vary by 0.1 psi due to display rounding. * Maximum Velocity of 14.19 ft/s occurs in the following pipe(s): (10-13) *** Device pressure loss (gain in the case of pumps) is calculated from the device's curve. If the device curve is printed with this report, it will appear below. The length of the device as shown in the table above comes from the CAD drawing. The friction loss per unit of length is calculated based upon the length and the curve-based loss/gain value. Internal ID and C Factor values are irrelevant as the device is not represented as an addition to any pipe, but is an individual item whose loss/gain is based solely on the curve data. File: Y:ENGINEERlNG3A.Project Files\C7236 L0T213 - LA COSTA\C7236 L0T213 - LA COSTA.dwg Date 11/19/2018 Copyright 2002-2012 Tyco Fire Protection Products Page 14 I Job: C7236 L0T213 - LA COSTA Device Graphs Pressure vs. Flow Function Design Area: 2; Supply Ref.: 1; Supply Name:1 3C: 20— 00- 90 - - - so 70- 60' — 50 20 - - -.--- 30 ------------------- ---. .-----..-.-- - to, 0. Flow, gpm Pressure Loss Function Design Area: 2; Valve Ref.: 112 (1 INCH WM, Size = 1); Inlet Node: 064; Outlet Node: 06-0 4psl31.5gpm 9- 4 - 9 4- 9- - - 4- 4 - 1.1 0 0 0 C = 0 Flow, gpm File: Y:\ENGlNEERlNG3A.Project Files\C7236 L0T213 - LA COSTA\C7236 L0T213 -LA COSTA.dwg Date 11/19/2018 Copyright 2002-2012 Tyco Fire Protection Products Page 15 Job: C7236 L01213 - LA COSTA Device Graphs Pressure Loss Function Design Area: 2; Valve Ret: 113 (RESI, Size = 1); Inlet Node: 084; Outlet Node: 08-0 g Flow, gpm File: Y:ENGINEERING13A.Project FilesC7236 LOT213 - LA COSTA\C7236 L01213 - LA COSTA.dwg Date 11/19/2018 Copyright 2002-2012 Tyco Fire Protection Products Page 16 I? 16 Is 14 13 12 II 61 a. o I- 9 (9 to 8 '7 a. 0 Page 1 of 8 SENJU SPRINKLER CO., LTD. Residential Lead Free Flat Concealed Sprinkler. - Pendent, I Model: RC-RES, K-Factor: 4.9, SIN: S58464 1!T GENERAL DESCRIPTION The Model RC-RES Residential Flat Concealed Sprinklers are automatic sprinklers of the compressed fusible solder type. They are decorative and fast responding. The Cover Plate Assembly hides the Deflector, Heat Responsive Element etc., which is concealed above the ceiling. The cover plate has a flat profile, and its diameter is extremely small (2-5/8 inch, 68mm). The push-on and/or thread-on, thread-off design of the concealed cover plate assembly allows for easy installation of the cover plate. Therefore, the Model RC-RES should be your first choice when aesthetics is the major consideration for ultimate appeal and unbeatable performance is desired. The Model RC-RES is designed for residential occupancies and is perfect for use in homes, hotels and other living quarters. The Model RC-RES is to be used in wet pipe residential sprinkler systems for One- and Two- Family Dwellings and Manufactured Homes per NFPA 131); wet pipe residential sprinkler systems for Residential Occupancies up to and Including Four Stories in Height per NFPA 13R; or, wet pipe sprinkler systems for the residential portions of any occupancies per NFPA 13. The Model RC-RES has a 4.9 (70.6 LPM/bar"2) K-factor that meets the required residential flow rates with minimal residual pressure, which allows for smaller pipe sizes and water supply requirements. For extended installation flexibility, the Model RC-RES provides 1/2 inch (12.8mm) vertical adjustment. This adjustment in installation decreases the need for precise cutting of the pipe that drops to the sprinkler and allows for a perfect fit with a range of pipe lengths. The heat sensitivity and water distribution design of Model RC-RES allows for an increased chance of residents to escape or evacuate in case of a fire. However, residential fire sprinkler systems are not a substitute for fire safety awareness or fire safety construction required by building codes. "Lead Free" is defined in the Reduction of Lead in Drinking Water Act (S.3874) endorsed by AWWA's Water Utility Council, and California Assembly Bill #1953 as having less than or equal to a weighted average of 0.25% lead in wetted surface of pipes, plumbing fittings and fixtures. WARNINGS The Model RC-RES must be installed and maintained in accordance with the rules stated herein as well as in compliance with the applicable standards of the National Fire Protection Association regulations and the standards of any other authorities having jurisdiction. In the event of this condition, consult the authorities having jurisdiction for guidance and approval. Failure to do so may impair the integrity of these devices. It is the responsibility of the installing contractor to provide a copy of this document to the owner or their representative, and in turn, it is the obligation of the owner to provide a copy of this document to a succeeding owner. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any related questions. Document No.U085163 Date Feb/05/2018 Page :2 of 8 TECHNICAL DATA Approvals: UL 8 Listed, NSF-61 -G Sprinkler Identification Number (SIN): SS8464 Maximum Working Pressure: 175psi (12.1bar) Discharge Coefficient (Nominal K-Factor): K=4.9 GPMlps1112 (70.6 LPM!bar112) Temperature Rating: 162°F (72°C) Sprinkler with 140°F (60°C) Cover Plate 175°F (79°C) Sprinkler with 140°F (60°C) Cover Plate 175°F (79°C) Sprinkler with 162°F (72°C) Cover Plate Color Code (Sprinkler) 162°F (720C): Uncolored 175°F (790C): White Color Code (Cover Plate) 140°F (60°C): No Mark 162°F (72°C): White-Colored Mark Vertical Adjustment: 112 inch (12.8 mm) Cover Plate Finishes: Standard Finishes- White, Ivory, Beige, Brown, Black, Nickel, Wood Grain Custom Finishes- Custom color and custom pattern cover plates are available on special order. Contact a Senju Sprinkler representative with any custom orders. Please see chart on Page 8 for more detail. Physical Characteristics: Ref. Figure 1 2-I1I6 (052mm) NEIILZ - Meriting t";;, I Year of Manufacture i bSlN:5S8464 K-1sker: K4.9 Temperatura Rating: l6iF/72C or 170/76'C Control No : 6P37 E INSFMark:NSF-61-G ___-- 'RES SPKR (1) Body (Copper Alloy) i Deflector (Phosphorus Bronze) (t Gasket (PTFE) [ r Cover Plate Assembly 2-5/8 (068mm) (4) Fusible Metal (Solder) or 3 1/4' (0 83nvn) I (l Heat Collector (Copper) or 2-5/8uaro (068mm) FIGURE 1. Model RC-RES K-4.9 Marking (Deflector) SIN 5S8464 -K-factor: K4.9 Temperature Rating: Color Code 162'F/)2C or 170/19C UL Mark 0 0 0• COVER PLATE SPRINKLER (Top view) (Bottom view) FIGURE 1-1. Marking (Color Code) OPERATION In case of fire, the solder component that holds together the Cover Plate and the Retainer melts. Then the Cover Plate is released at once. As a result, the Deflector drops down to the intended position. Two Heat Collectors are exposed to fire, and when sufficient heat from the fire is reached, internal Components of the sprinkler fall apart. This leads to the water flow to be distributed on the affected fire area. (Ref. Figure 2) Normal Condition Cover Plate Operation Sprinkler Operation Water Discharge FIGURE 2. OPERATION PROCESS (The figure is for illustrative pumoses only) Document No. U085163 Date : Feb/05/2018 Page :3 of 8 DESIGN CRITERIA The herein stated rules for use and installation of Model RC-RES are provided by the manufacturer and must be strictly implemented for safe and full results. NOTES Residential Fire Sprinkler Systems should only be designed and installed by individuals who are completely familiar with automatic sprinkler system design, installation procedures, and techniques. Several criteria may apply to the installation and usage of each sprinkler. Consequently, it is recommended that the sprinkler system designer review and develop a working understanding of the complete 11sf of criteria prior to initiating the design of the sprinkler system. Questions concerning sprinkler installation and usage criteria, which are not covered by the following instructions, should be submitted to your contracted company. Include sketches and technical details, as appropriate. In some instances, the requirements of this document may concern specifications which are more stringent, and which take precedence over those specified in NFPA 13, 13D, 13R, or by the authority ha ving jurisdiction. The Model RC-RES must not be used in applications where the air pressure above the ceiling is greater than that below. Inspect all sprinklers after installation to ensure that both the gap between the cover plate, ceiling and the 6 slots in the cup are open and free from any air flow impediment. The spray from the sprinkler is distributed radially outward and downward from the sprinkler deflector. Consequently, the sprinklers must be located such that there will be no blind spaces shielded from spray by partitions, room dividers, overhangs or other parts of the dwelling structure. The number of sprinklers within each compartment (as defined by NFPA 13, 13D, or 13R) must be kept as few as possible. Do NOT use more sprinklers than necessary to cover a particular space. Use only the Cover Plate provided for the Model RC-RES. The sprinkler must be secured in place by firmly fastening the sprinkler system piping to the structure. If the sprinkler is not properly secured in position, reaction forces resulting from sprinkler operation could alter its orientation and its water distribution pattern. Obstruction to Water Distribution Locations of sprinklers must follow the obstruction rules of NFPA 13 for Residential Sprinklers. General Service Conditions The Model RC-RES must only be utilized in WET PIPE sprinkler systems. Heat Source Criteria Refer to NFPA 13D, 13R or 13 for the requirements relating to the prevention of possible activation of the Heat Responsive Element of Model RC-RES, due to the exposure of a heat source other than an actual fire. Available Sprinkler Temperature Ratings Sprinkler Temperature Classification Sprinkler Nominal Temperature Rating Maximum Ambient Ceiling Temperature Temperature Rating of the Cover Plate Assembly Ordinary 162°F (72°C) 100°F (38°C) 140°F (60°C) Intermediate 175°F (79°C) 150°F (66°C) 140°F (60°C)" Intermediate 175°F (79°C) 150°F (66°C) 162°F (72°C) 1) Maximum ambient temperature for the Cover Plate Assembly is 100°F (38°C). Precautionary Warnings for Corrosive Environments Model RC-RES sprinklers should not be installed where they may be subjected to a corrosive environment including the following: Chlorine ion and Chloride environment. Stress corrosion cracking may be caused by exposure to environments with Chlorine ion and Chloride. Exposure to this environment may result in sprinklers operating under Non-Fire conditions or Not Operating when exposed to an actual fire. Sprinkler system piping with Copper. Sprinkler systems should be constructed in compliance with the applicable standards and the requirements for copper piping when copper piping is used in the sprinkler system. (Reference standards NFPA 13, ASTM 6813, B828, and CDA (Copper Development Association) - Solder Joint) All residual flux must be removed from the interior and exterior of the copper piping by thoroughly flushing before installation of the Sprinkler Heads. Otherwise, residues of flux may cause corrosion and leakage in the sprinkler system. Document No. U085163 Date : Feb/05/2018 Page :4 of 8 Hydraulic Design Criteria The minimum required sprinkler flow rates for systems designed to NFPA 13D or 13R are given in Table A as a function of temperature rating and the maximum allowable coverage area. The sprinkler flow rate is the minimum required discharge from the most hydraulically demanding sprinkler from each of the total number of design sprinklers" as specified in NFPA 13D or 13R. For systems designed to NFPA 13, the number of designed sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: The flow rates given in Table A for NFPA 13D and 13R as a function of temperature rating and maximum allowable coverage area. A minimum discharge of 0.1GPM/sq.ft. [4.07LPM/sq.m] over the 'design area" comprised of the four most hydraulically demanding sprinklers for the actual coverage area being protected by the four sprinklers. TABLE A. NFPA 13D & 13R WET PIPE HYDRAULIC DESIGN CRITERIA for Model SS8464 For systems with ceiling types smooth flat horizontal, or beamed, or sloped, in accordance with NFPA 13D, 13R or 13 as applicable. Ordinary Intermediate Maximum Maximum Temperature Rating Temperature Rating Minimum Coverage Spacing 162°F (72°C) 175°F (79°C) Deflector Installation Spacing Area Ft. x Ft. Ft. to Ceiling Type Ft. Flow(b) Pressure Flow(') Pressure (m xm) (m) GPM PSI GPM psi (m) (LPM) (bar) (LPM) (bar) 12x12 12 13 7.0 13 7.0 Smooth (3.74.7) (3.7) (49.2) (0.48) (49.2) (0.48) Ceilings 3/8 to 7/8 Inches. 1014 14 13 7.0 13 7.0 (4.3x4.3) (4.3) (49.2) (0.48) (49.2) (0.48) Beamed Ceilings 16x16 16 13 7.0 14 8.2 per NFPA 8 (4.9x4.9) (4.9) (49.2) (0.48) (53.0) (0.57) 13D, 13R Concealed (2.4) or 13 Installed 18x18 18 17 12.0 18 13.5 in beam (5.5x5.5) (5.5) (64.3) (0.83) (68.1) (0.93) 3/8 to 7/8 inches below 20x20 20 21 18.4 bottom of (6.14.1) (6.1) (79.5) (1.27) - - beam. For coverage area dimensions less than the above mentioned, it needs to use the minimum required flow for the Next Higher Coverage Area listed. Requirement is based on minimum flow in GPM/LPM from each sprinkler. The associated residual pressures are calculated using the nominal K-Factor. Refer to Hydraulic Design Criteria Section for details. Sprinkler Spacing Criteria The minimum spacing between sprinklers is 8 feet (2.4m). The maximum spacing between sprinklers cannot go beyond the coverage area calculated by using the specific hydraulic factors. (Ref. Table A) Document No. U085163 Date : Feb/05/2018 Page :5 of 8 INSTALLATION The Model RC-RES must be installed in accordance with the following instructions: NOTES Do not use any sprinklers which have been subjected to potential mechanical damage. Do not use any sprinklers which show deformation or cracking in either the Sprinkler or the Protective Cap. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to the sprinklers that could cause improper operation or non-operation. The Protective Cap must remain on the sprinkler during installation and until the ceiling installation is completed. The Protective Cap must be removed to place the sprinkler in service. Use a torque of to 14 ftlbs (9.5 to 19.0 Nm) to achieve a 1/2 inch NPT sprinkler joint. If you exceed the recommended maximum torque, this could result in damage to the sprinkler Inlet, which may lead to leakage from the sprinkler. Use only NR-H model wrench socket for installation of RC-RES sprinklers. Use of any other wrench or socket is prohibited and may cause damage to the sprinkler. In case of insufficient adjustment in Cover Plate installation, do not try to overly tighten, screw the sprinkler too loosely or make any modification to the cover plate assembly. Readjust the sprinkler fitting for a better fit. Do not rotate the Cap Remover RC to the left with force when placing the two hook arms into place. The Installed sprinkler may become loosened, which may cause water leakage. Installing Procedure Step I The installation requirements for the sprinkler are as follows: to be installed only in the pendent position with the waterway perpendicular to the ceiling. Install the sprinkler fitting so that the distance from the face of the fitting to the mounting surface will be nominally 2 inch (50.8mm) as shown in Figure 3. Step 2 With pipe thread sealant applied to the threads, hand tighten the sprinkler into the sprinkler fitting. Then tighten it with the Socket NR-H or Ratchet & Socket NR-H Combination (Ref. Figure 4). The grooves of the Socket must fit perfectly with the grooves on the Sprinkler for proper installation (Ref. Figure 4). Step 3 If desired, the Protective Cap may also be used to locate the center of the clearance hole by gently pushing the ceiling material against the center point of the Protective Cap. Before the installation of the ceiling, the sprinkler installation can be started with a 2-3/8 inch (60mm) diameter clearance hole (Ref. Figure 3). Use the "Vertical Adjustment' indicator on the Protective Cap to check for proper installation height (Ref. Figure 3). Make a Sooce Hero F•--1 Do Not I Ave. 1/4 Mi (8.4mm) I n.1/8' (3.2mm) Groove on the Sprinkler A=:nt Protective Cop Groove on the Socket 7 M2ot~inting _ Socket NA-H Mounting 2 3/ 8 (060mm) Surface Ratchet Ceding Hole Diameter conREcrl LINCORRECTI L I IIL FIGURE 3. INSTALLATION FIGURE 4. RATCHET & SOCKET Step 4 Use the Cap Remover RC to remove the Protective Cap (Ref. Figure 5), and then push or screw a Cover Plate Assembly on the Cup of the Sprinkler by hand until its flange just has contact with the ceiling (Ref. Figure 6 and Figure 7). Stop tightening the Cover Plate Assembly once the flange has contact with the ceiling. If the ceiling has been lifted from its normal position in the process of tightening the Cover Plate Assembly, readjust the cover plate assembly as necessary. If the flange of the Cover Plate Assembly cannot contact the ceiling sufficiently, readjust the sprinkler fitting as necessary. When properly installed, there is a nominal 1/16 inch (1.6mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 6. Document No.U085163 Date : Feb/05/2018 Page 6 of Hock up Sprinkler Head Protective Cap jj Cap Remover RC Pull down Stop 1 Step 2 Stop 3 FIGURE 5. PROTECTIVE CAP REMOVAL 8 - Cover Plato Assembly L 2-5/c (ib 60mm) 1 or 3-114" (083mm) or 2-5/8sqocro (068mm) FIGURE 6. INSTALLATION (COVER PLATE ASSEMBLY) [INCORRECT I LOORRECT I I INCORRECT FIGURE 7. INSTALLATION (CORRECT and INCORRECT) Document No. U085163 Date Feb/05/2018 Page : 7 of 8 CARE AND MAINTENANCE The following instructions must be implemented for the maintenance and service of the Model RC-RES NOTES Wet pipe sprinkler systems must be maintained at a minimum temperature of 40°F/40C to prevent freezing and bursting of the pipe and/or sprinklers. Automatic sprinklers are not to be tested with a heat source. Operation of the heat responsive element can result. Absence of a Cover Plate Assembly may delay the response time of the sprinkler in case of a fire. Install the cover plate assembly properly, as shown in Figure 6. Improper installation of the cover plate assembly may cause improper operation or non-operation. If the ceiling is to be repainted after the installation of the Sprinkler, care must be exercised to ensure that the new paint does not seal off any of the air gap. Factory painted Cover Plates must not be repainted. They should be replaced, if necessary, by factory painted cover plates. Non-factory applied paint may adversely delay or prevent sprinkler operation in case of a fire. Do not pull the Cover Plate. Separation may result. In preparation for maintenance of the fire protection system, permission to close the main control valve must be obtained from the proper authorities, and all affected parties by this action, and must be informed before the maintenance session can commence. Do NOT enclose any sprinklers within drapes, curtains, or valances. Do NOT hang anything from the sprinklers. Do NOT clean the sprinklers with soap and/or water, detergents, ammonia, cleaning fluids, or other chemicals. Remove dust, lint, cobwebs, cocoons, insects, and larvae by gently brushing with a feather duster or gently vacuuming with a soft bristle (i.e., dusting) brush attachment. Exercise suitable safety precautions in the use and storage of highly flammable materials. The rapid rate of fire development and spread of these materials can reduce the ability of the sprinkler system to aid in the control of a fire involving such hazards. Leaking or corroded sprinklers must be replaced. Automatic Sprinklers must never be shipped or stored where the temperature exceeds 1000F/380C. Automatic sprinkler must never be physically altered, such as painted, plated, or coated, once shipped from the factory. If the sprinklers have been in any way modified, they must be replaced. Great caution must be applied to prevent damage to the sprinklers at all stages - before, during, and after installation. Damaged units because of dropping, hitting, over-tightening, or wrench slippage, must be replaced. The Model RC-RES must only be replaced with pendent sprinklers which are listed for residential fire protection service and which have the same nominal K-Factor, the same coverage area, and the same or lower flow ratings (as indicated under Table A "Hydraulic Design Criteria"). When remodeling, such as by adding false beams or light fixtures or changing the location of compartment wails, first verify that the new construction will not violate the installation requirements of the applicable standards of NFPA. Alter the new construction and/or the sprinkler system to suit the requirements of this document and the applicable NFPA regulations. The owner is responsible for the maintenance of the sprinkler system, including inspection and testing of its compliance with this document, as well as the standards of the National Fire Protection Association (e.g., NFPA 25), and the regulations of any other authorities having jurisdiction. The owner should direct any questions regarding the above rules and regulations to the installing contractors or the sprinkler manufacturer. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with NFPA 25. Document No. U085163 Date . Feb/05/2018 Page :8 of 8 ORDER PROCEDURE When placing an order, please contact a local distributor with the following information (Model Name, Temperature Rating and Finish). Sprinkler Model: RC-RES (SIN: SS8464, Residential Flat Concealed Sprinkler, Pendent, K4.9, Temperature: 162°F (72°C) or 175°F (79°C)) Cover Plate Assembly 2-5/8 inch ( 68mm) or 3-1/4 inch (0 83mm) or 2-5/8 inch square (068mm), Order Separately from Sprinkler Please refer to the chart below for available sizes, temperature, and finishes. Standard Finishes Custom Finishes White Ivory Beige Brown Black Nickel Wood Grain Custom Color Custom Pattern 2-5/8° Round, 140°F o o - - - 0 0 3-1/4" Round, 140°F 0 0 0 0 0 0 0 0 0 2-5/8" Square, 140°F 0 - - - 0 0 2-5/8" Round, 162°F I 0 - - - - - - 0 0 3-1/4" Round, 162°F 0 1 - - - - - - 0 0 Tools for Installation of Model RC-RES Socket NR-H For use with a 3/8° drive ratchet (not included) Socket NR-H Plastic For use with a 1/2" drive ratchet (not included) Cap Remover RC Document No.U085163 Date : Feb/05/2018 Fl Res 30, 49, 58 & 76 Recessed Pendent I Fl El Res 30, 49, 58 & 76 Recessed Pendent / FP Fl Res 30, 49, 58 & 76 Fl Res 44 & 58 Fl Res 44SWC CCP Pendent Recessed HSW/F2 ç-b Bulletin 135 Rev. M Rel bili Model Fl Residential Sprinklers for Design Density of .05 gpm/ft2 C3 -S C) 01 CD Model Fl Res Sprinklers engineered for the lowest flows to meet the minimum design density of .05 gpmflt2 Types: Fl Res 30Pendent Fl Res 30 Recessed Pendent/F2 Fl Res 30 Recessed Pendent/FP Fl Res 49 Pendent Fl Res 49 Recessed Pendent/Fl Fl Res 49 Recessed Pendent/FP F1 Res 58 Pendent Fl Res 58 Recessed Pendent/Fl Fl Res 58 Recessed Pendent/FP Fl Res 76 Pendent Fl Res 76 Recessed Pendent/Fl Fl Res 76 Recessed Pendent/FP Fl Res 30 CCP Pendent Fl Res 49 CCP Pendent Fl Res 58 CCP Pendent Fl Res 76 CCP Pendent F1 Res 44HSW Fl Res 44 Recessed HSW/F2 Fl Res 58 HSW Fl Res 58 HSWX KRes58 HSWX Fl Res 58 HSW Recessed HSW/F2 Fl Res 44SWC Listings & Approvals 1. Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) Sprinklers for .10 Density: Refer to Bulletin 176 UL Listing Category Residential Automatic Sprinkler UL Guide Number VKKW Patents US Patent No. 6,516,893 applies to the Model Fl Res 49 & 58 Pendent Sprinklers US Patent No. 7,353,882 applies to Model Fl Res 44 & 58 HSW Sprinklers US Patent No. 7,784,555 applies to Model Fl Res 44 SWC Sprinklers Product Description Model Fl Res Pendent sprinklers (Figs. 1, 2, 3, & 4) are fast response sprinklers combining excellent durability, high sensitiv- ity glass-bulb and low profile decorative design. The Fl Res Horizontal Sidewall sprinklers (Figs. 5, 6 & 7) are equally attrac- ve when above ceiling piping cannot be used. The 3mm glass-bulb pendent sprinklers permit the efficient use of residential water supplies for sprinkler coverage in residential fire protection design. The low flow Fl Res sprinklers are specially engineered for fast thermal response to meet the sensitive fire protection applica- tion needs of the latest residential market standards (UL 1626 Standard). Upon fire conditions, rising heat causes a sprinkler's heat-sensitive element, glass bulb or link to actuate, releasing the waterway for water flow onto the deflector, evenly distributing the discharged water to control a fire. Technical Data: Thermal Sensor: Soldered Element (Link) or Nominal 3mm glass-bulb Sprinkler Frame: Brass Casting Sprinklers' Pressure Rating: 175 psi Factory Hydrostatically Tested to 500 psi Thread Size: ½"NPT(R½) K-Factor: 3.0 (43.2) (Actual) - Fl Res 30 Pendent Sprinkler 4.9 (70.6) (Actual) - Fl Res 49 Pendent Sprinkler 5.8 (83.5) (Actual) - Fl Res 58 Pendent& HSW Sprinkler 7.6 (109)(Actual) Fl Res 76 Pendent Sprinkler 4.4(63) (Actual) - Fl Res 44 HSW Sprinkler Density: Minimum 0.05 gpm/ft2 Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Application Model Fl Res Sprinklers are used for Residential Fire Pro- tection according to UL 1626 Standard*. For ceiling types: Smooth Flat Horizontal, or beamed, or sloped, in accordance with NFPA 13D, 13R, or 13 2013 editions. Be sure that orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of The Na- tional Fire Protection Association or the approving authority having jurisdiction. Installation Models Fl Res sprinklers are to be installed as shown. Model Fl, F2 and FP Escutcheons, illustrated herewith, are Escutcheon*, Fl or F2, Data: the only recessed escutcheons to be used with Model Fl Res sprinklers. Use of any other recessed escutcheon will void all approvals and warranties. For installing Model Fl Res Pen- dent sprinklers use only the Model D sprinkler Wrench; for installing Models Fl Res Recessed Pendent, CCP & SWC sprinklers use only the Model GFR2 sprinkler wrench; for in- stalling Model Fl Res Recessed HSW sprinklers use only the Model GFR2 Sprinkler Wrench. Use of wrenches other than those specified may damage these sprinklers. Install Fl Res 44 with a ceiling to deflector distance of 4" - 12". Flow arrow on deflector must point away from near wall and 'Top" mark- ing must face ceiling. Type Adjustment "A" Face of fitting to ceiling Deflector Distance below bottom of beam Inch (mm) Inch (mm) Inch (mm) Inch (mm) Fl 3/4 (19.0) Mm. Recessed = 1/8 (41.3) 3/8 (g.5) 13/4 (44.4) Max. Recessed =T/8 (22.2) 11/8 (28.6) 1(25.4) F2 ½(12.7) Mm. Recessed = 1/6 (41.3) -1/8 (9.5) 13/4 (44.4) Max. Recessed = 1 Va (28.6) 1 7/8 (22.2) 11/4 (31.7) *Ncte: Escutcheons Fl or F2 may be used with Model Fl Res 49, 58 & 76 Recessed Pendent Sprinkler Model Fl Res 30 Recessed Pendent / F2 Model Fl Res 30, 49, 58 & 76 Pendent • Model Fl Res 49, 58 & 76 Recessed Pendent I Fl IlIi ----------------- El escutcheon, /." (19mm) adjustment 121/4 HOLE (7.2mm) i 75/I6 OH [492m ] TURN COLLAR UN71L 112 REDUCER TIGHT AGAINST SPRINKLER FACE OF nm,' a To WRENCH BOSS. CEILING DIMENSION: 3/8- I 1/8 (Fl ESCUTCHEON) 3/8-7/8 (F2 ESCUTCHEON) ADJUSTMENT 27/32 OH jçJ.2mm) (72.2mm3' Fig. 1 Fig. 2 Technical Data: F11 Res 30 Pendent and Recessed Pendent (SIN R3511) Thread Size Nominal Orifice I Inch (mm) Max. Pressure psi (bar) I Sprinkler Temp. Rating Max. Ambient Temp. I Actual K--Sprinkler I Factor Length Inch (mm) I I OF I °C °F I °C ½"NPT (R½) 21/ (8.2) I 175 (12) I 155 I 175 68 I 79 100 I 38 3.0(43.2) 2.25 (57) Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (l55°Fi8°C) Intermediate Temp. Rating (175°F1790C) Top of Deflector to Ceiling inch (mm) Minimum Spacing Ft (m) Flow GPM (Llmln) Pressure PSI (bar) Flow GPM (Llmin) Pressure PSI (bar) 12 x 12(3,6 x 3,6) 12(3.6) 8(30,3) 7.0 (0,48) 8(30,3) 7.0(0,48) Smooth ceilings 11/4 to 4(31.7 to 102) using F2 escutcheon. 14 x 14(4,3 x 4,3) 14(4,3) 10(37,8) 11(0,76) 10(37,8) 11(0,76) Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams 11% to 13 (31.7 to 44.4) using F2 escutcheon 8(2,4) 16 X 16 (4,9 X 4,9) 16 (4,9) 13 (49) 18.8(1,3) 13(49) 18.8(1,3) For Ceiling types refer to NFPA 13, 13R or 13D 2. Technical Data: Fl Res 49 Pendent and Recessed Pendent (SIN R3516) Thread I Nominal Orifice I Max. Sprinkler Max. Actual I Sprinkler Size Inch (mm) Pressure Temp. Rsting Ambient Temp. I K Length IOF OC i OF IOC I psi (bar) Factor Inch (mm) ½' NPT (R½) 7/1e" (11) 175(12) 155 175 68 79 I 100 I I 150 I 38 66 4.9(70.6) 2.25(57) Ordinary Temp. Rating Intermediate Temp. Rating Top of Deflector Minimum Max. Coverage area Max. Spacing (155°FMS°C) (175°F179°C) to ceiling Spacing Flow Pressure Flow Pressure FtxFt(mxm) Ft (m) GPM (Llmln) PSI (bar) GPM (1/mm) PSI () Inch (mm) Ft (m) 12 x 12(3,6 x 3,6) 12(3,6) 13 (49) 7.0(0,48) 13(49) 7.0(0,48) Smooth Ceilings 11/4 to 4(31.7 to 102) using F2 escutcheon. 14 x 14 (4,3 x 4,3) 14(4,3) 13 (49) 7.0 (0,48) 13 (49) 7.0 (0,48) 1 t 4(25.4 to 102) using Fl escutcheon. 16 x 16(4,9 x 4,9) 16(4,9) 13(49) 7.0(0,48) 13(49) 7.0(0,48) Beamed Ceilings per NFPA 13D, 13R or 13 installed in 8(2,4) 18 x 18(5,5 x 5,5) 18(5,5) 17(64,3) 12(0,83) 17(64,3) 12(0,83) beams 11/4 to 1A (31.7 to 44.4) using F2 escutcheon, 1 20 x 20(6,1 x 6,1) 20(6,1) 20 (75,7) 16.7 (1,14) 20(75,7) 16,7(1,14) to 1A(25.4 t044.4)using Fl escutcheon For Ceiling types refer to NFPA 13, 13R or 13D Ordinary Temp. Rating Intermediate Temp. Rating Top of Deflector Minimum Max. Coverage area Max. Spacing (155°FM8°C) (1750 C) to Ceiling Spacing Flow Pressure Flow Pressure Ft x Ft (mx m) Ft (m) GPM (Llmin) PSI (bar) GPM (L/min) PSI (bar) Inch (mm) Ft (m) 12 x 12(3,6 x 3,6) 12(3,6) 15(57) 9.4(0,65) 15(57) 9.4(0,65) Smooth Ceilings 4 to 8(100 to 203) using F2 escutcheon. 14 x 14(4,3 x 4,3) 14(4,3) 16(60,5) 10.6(0,73) 16 (60,5) 10.6(0,73) 4 to 8(100 to 203) using Fl escutcheon. 16 x 16(4,9 x 4,9) 16(4,9) 17(64,3) 12.0(0,83) 17(64,3) 12.0(0,83) Beamed Ceilings per NFPA 131), 13R or 13 installed in beams 8(2,4) 18 x 18(5,5 X 5,5) 18(5,5) 19(72) 15.0(1,0) 19(72) 15.0(1,0) 41/4 to8(108 to 203) using F2 escutcheon, 4 to 8(100 to 203) 20 x 20(6,1 x 6,1) 20(6,1) 22 (83,2) 20.2(1,4) 22(83,2) 20.2(1,4) using Fl escutcheon Technical Data: F1 Res 58 Pendent and Recessed Pendent (SIN R3513) Thread I Nominal Orifice I Max. I Sprinkler I Max. I I Actual I Sprinkler Size Inch (mm) Pressure Temp. Rating I Ambient Temp. I K Factor I Length OF I °C OF I °C psi (bar) I I Inch (fflm) ½" NPT (R½) I ½" (13) 175 (12) 155 175 68 79 I 100 I 150 38 I 66 5.8 (83.5) 2.25(57) Ordinary Temp. Rating Intermediate Temp. Rating Top of Deflector Minimum Max. Coverage area Max. Spacing (l55°Fi8°C) (175°Ffl'9°C) to Ceiling Spacing Row Pressure Row Pressure Ft x Ft (mx m) Ft (m) Inch (mm) Ft (m) GPM (L/mln) PSI (bar) GPM (L/min) PSI (bar) 12 x 12(3,6 x 3,6) 12(3,6) 16(61) 7.6 (0,53) 16(61) 7.6(0,53) Smooth Ceilings 1¼ to 4(31.7 to 102) using F2 escutcheon. 14 X 14(4,3 X 4,3) 14(4,3) 16 (61) 7.6(0,53) 16(61) 7.6(0,53) 1 t 4(25.4 to 102) using Fl escutcheon. 16 x 16(4,9 x 4,9) 16(4,9) 16(61) 7.6(0,53) 16(61) 7.6(0,53) Beamed Ceilings per NFPA 13D, I3R or 13 installed in beams 8(2,4) 18 X 18(5,5 X 5,5) 18(5,5) 19(72) 10.8(0,75) 19(72) 10.8(0,75) 11/4 to 14 (31.7 to 44.4) using F2 escutcheon, 1 t 13/4 (25A to 20 X 20(6,1 X 6,1) 20(6,1) 22(83,3) 14.4(1,0) 22 (83,3) 44.4) using Fl escutcheon For Ceiling types refer to NFPA 13, 13R or 130 3. Technical Data: Fl Res 76 Pendent and Recessed Pendent (SIN R7618) Thread Nominal Orifice Max. Sprinkler I Max. K Sprinkler Size I Inch (mm) Pressure Temp. Rating I Ambient Temp. Factor I Length I I psi (bar) Inch (mm) 3/4' NPT (R3/4) 17/n" (13.5) I I 175 (12) 155 175 I 68 79 100 I 38 I 150 I 66 I 7.6 (109) i I 2.25(57) I Ordinary Temp. Rating Intermediate Temp. Rating Minimum Max. Coverage area Max. Spacing (1 5W50 (175°F/79°C) Top of Deflector to Ceiling spacing Row Pressure Flow GPM Pressure Ft x Ft(m x m) Ft (m) Inch (mm) GPM (1/mm) PSI (bar) (Llmln) PSI (bar) Ft (m) 12 x 12 (3,6 x 3,6) 12(3,6) 21 (79,5) 7.6(0,53) 21(79,5) 7.6(0,53) Smooth Ceilings 41/4 to 8(108 o 203) using F2 escutcheon. 14 x 14 (4,3 x 4,3) 14(4,3) 21 (79,5) 7.6(0,53) 21(79,5) 7.6(053) 4t08(100t0203) using Fl escutcheon. 16 x 16(4,9 x 4,9) 16(4,9) 21(79,5) 7.6(0,53) 21(79,5) 7.6(0,53) Beamed Ceilings per NFPA 13D, 13R or 13 installed in 8(2,4) 18x 18(5,5x5,5) 18(5,5) 21(79,5) 7.6(0,53) 21(79,5) 7,6(0,53) beams 4¼t08(108t0203)us- ing F2 escutcheon, 4 to 8(100 20 X 20(6,1 X 6,1) 20(6,1) 23(87,1) 9.2(0,63) 23(87,1) 9.2(0,63) to 203) using Fl escutcheon For Ceilina tvDes refer to NFPA 13. 13R or 13D Model Fl Res 30. 49. 58 & 76 CCP Pendent* * Not listed for corrosion resistance. - 2 5/8" (66.7mm) 014. 2 5/76" 014. HOLE IN CEILING (58.7mm) CUP 11 1- I"x1/2" REDUCER CUP CEILING _____________ I 7/4" (37.5mm] MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION "C" "A" COVER ADJUSTMENT HEIGHT 3 5/16" 014. 135FG04E I [84.1mm] Fl RES 30, 49. 58 & 76 CCP PEND. Fig. 3 Note: The Fl Res 76 will use a 1" x Y4" reducer. CCP Cover Plate Data: "A" Cover Adjustment CCP Height "C" Deflector Distance below bottom Inch (mm) Inch (mm) of beam Inch (mm) 1/2 (12.7) 15h6 (24) ½(13) - 1(25.4) s/is (7.9) /4(19) 1 1/2 (13)- 1(25.4) Model Fl Res 30, 49, 58 & 76 FP push-on/thread-off escutcheon 2 5/8" 0/A. (66.7mm] HOLE IN CEILING - 2 5/76" OIA. r— [58.7mm] - ----j----- 1" X 1/2" REDUCER . 11 1 7/2[38.1mm] MAX. FACE OF FITTING TO FACE OF CEILING 7/2" [13mm] MAX.J FP ADJUSTMENT Fl RES 49 PENDENT/FP Fig. 4 FP Escutcheon Data: FP Position "A" Deflector Distance below bottom Inch (mm) of beam Inch (mm) Max. Recessed /I6(11) 1/2 (12.7) Mm. Recessed 1 '/ie (24) 1(25.4) Note: Sprinklers shown in Fig. 3 and Fig. 4 are not suitable for installation in Ceilings which have positive pressure in the space above. 4. Technical Data: F1 Res 30 CCP Pendent and Recessed PendentlFP (SIN R3511) Thread I Nominal I Max. CCP Assembly Max. I K Sprinkler I ISize Orifice Pressure Temp. at I Ambient Temp. I Factor I Length I OF I I OF I I Inch (mm) I psi (bar) I Inch (mm) I ½" NPT (R1./2) 21/04" (8.2) 175(12) I 135 57 100 I I 38 3.0(43.2) I 2.25 (57) I I Ordinary Temp. Rating Minimum Max. Coverage area Max. Spacing (155°FI8°C) Top of Deflector to Ceiling Spacing Flow Pressure Ft x Ft (mx m) Ft (m) Inch (mm) GPM (Llmin) PSI (bar) Ft (m) Smooth Ceilings /2 to 1(13 to 25.4) using CCP. 12 X 12 (3,6 X 3,6) 12(3,6) 8(30.3) 7.0 (0,48) ½ to 1(13 to 25.4) using FP escutcheon. Beamed Ceilings per NFPA 13D, 13R or 13 installed in 8(2.4) 14 x 14 (4,3 x 4,3) 14(4,3) 11(37,8) 13.4 (0,92) beams 1/2 to 1(13 to 25.4) using CCP. 1/2 to 1(13 to 25.4) using FP escutcheon. For Ceilina Woes refer to NFPA 13. 13R or 13D Technical Data: F1 Res 49 CCP Pendent and Recessed Pendent/FP (SIN 3516) Nominal CCP Max . Thread Orifice Max. Assembly Ambient K Sprinkler Size Inch Pressure Temp. Temp. Factor Length (mm) psi (bar) Rating Inch (mm) OF I°C OF IOC 1/2" NPT (R½) /18" (11) 175(12) 135 I 57 100 I 38 4.9 (70.6) 2.25(57) Max. Coverage Ordinary Temp. Rating Minimum area Max. Spacing (1550 80C) Top of Deflector to Ceiling Spacing Flow Pressure Ft x Ft (m x m) Ft (m) inch (mm) Ft (m) GPM (L/min) PSI (bar) 12 x 12(3,6 x 3,6) 12(3,6) 13(49) 7.0 (0,48) Smooth Ceilings ½ to 1(13 to 25.4) using 14 x 14(4,3 x 4,3) 14(4,3) 13(49) 7.0(0,48) CCP. /2 to 1(13 to 25.4) using FP escutcheon. 16 x 16(4,9 x 4,9) 16(4,9) 14(53) 8.2(0,56) Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams ½ to 1(13 to 25.4) using 8(2,4) 18x 18(5,5x5,5) 18(5,5) 18 (68,1) 13.5 (0,93) CCP. ½ to 1(13 to 25.4) using FP escutcheon. 20 x 20 (6,1 x 6, 1) 20(6,1) 20(75,7) 16.7(1,14) For Ceiling types refer to NFPA 13, 13R or 130 Technical Data: F1 Res 58 CCP Pendent and Recessed Pendent/FP (SIN R3513) Thread Nominal I Max. I CCP Assembly I Max. I I K Sprinkler Size Orifice I Pressure I Temp. Rating I Ambient Temp. Factor Length OF I °C I OF I °C I Inch (mm) psi (bar) I Inch (mm) ½" NPT (R½) '/2" (13) I 175 (12) 135 57 100 38 5.8(83.5) 2.25 (57) Max. Coverage Ordinary Temp. Rating Minimum area Max. Spacing (1550 8-C) Top of Deflector to Ceiling Spacing Ft x Ft (m x m) . Ft (m) Flow Pressure Inch (mm) Ft (m) GPM (L/min) PSI (bar) 12 x 12(3,6 x 3,6) 12(3,6) 16(61) 7.6(0,53) Smooth Ceilings ½ to 1(13 to 25.4) using CCR ½ to 1(13 to 25.4) using FP escutcheon. 14 x 14(4,3 x 4,3) 14(4,3) 16(61) 7.6(0,53) 16 x 16 (4,9 x 4,9) 16(4.9) 16(61) 7.6 (0,53) Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams ½ to 1(13 to 25.4) using CCP. 8(2,4) 18 x 18(5,5 x 5,5) 18(5,5) 19(72) 10.8 (0,75) ½ to 1(13 to 25.4) using FP escutcheon. 20 x 20 (6,1 x 6, 1) 20(6,1) 22(83,3) 14.4(1,0) For Ceiling types refer to NFPA 13, 13R or 13D 5. Technical Data: F1 Res 76 CCP Pendent and Recessed Pendent/FP (SIN R7618) Nominal Max. I CCP Assembly Max. I I Sprinkler Thread Orifice I Pressure I Temp. Rating Ambient Temp. I K Length size Inch (mm) I psi (bar) Factor I Inch (mm) I OF °F I CC 3/4" NPT 17/32" (13.5) 175(12) 135 t::~C 100 150 I 38 I 66 7,6(109) 2.25(57) Max. coverage Ordinary Temp. Rating Minimum area Max. Spacing (155°FI8°C) Top of Deflector to Ceiling Spacing Flow Pressure Ft x Ft (m x m) Ft (m) Inch (mm) Ft (m) GPM (Llmin) PSI (bar) 12 x 12(3,6 x 3,6) 12(3.6) 21(79,5) 7.6(0,53) Smooth Ceilings ½ to 1(13 to 25.4) using CCP. /2 to 1(13 to 25.4) using FP escutcheon. 14 x 14 (4,3 x 4,3) 14(4.3) 21(79,5) 7.6 (0,53) 16 x 16(4,9 x 4,9) 16(4,9) 21(79,5) 7.6(0,53) Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams ½ to 1(13 to 25.4) using CCP. 8(2,4) 18x 18(5,5 x 5,5) 18(5.5) 22(83,3) 8.4 (0,58) ½ to 1 (13 to 25.4) using FP escutcheon. 20x20(6,1 x6,1) 20(6,1) 25 (94,6) 10.8 (0,74) For Ceiling types refer to NFPA 13, 13R or 13D Model Fl Res 44 & 58 HSW FACE OP F3TI7NG TO - /4" MIN. WALL DIMENSION - L.ômmj 2 7/4" HOLE 014. (5 7.2mm) (32mm) CEILING TO " 7" X 7/2" REDUCER DIMENSION - . DEFLECTOR [49tf_k227 /32" DIA. 2mm) COLLAR U7$ [72. TURN TIGHT AGAINST SPRINKLER WRENCH BOSS. 1/2" (13mm) -H IJ5FGo6-0 ADJUSTMENT Fl RES 58 & 44 HSW/F2 Fig. 5 Technical Data: Fl Res 44 HSW & HSW/F2 (SIN R3531) Thread Nominal Max. Sprinkler Max. Ambient K Sprinkler Size Orifice Pressure Temp. Rating Temp. Factor Length ____ Inch (mm) _____ psi (bar) ____ Inch (mm) bc OF I OC ½" NPT (R½) s/a" (10) 175(12) 155 175 I 68 I 79 100 150 38 I 66 4.4(63) 2.45(62) F2 escutcheon, 1/2" (13mm) adjustment Escutcheon, F2, Data: Face of Fitting Type Adjustment to wall Inch (mm) Inch (mm) F2 V2(13) 3lie - 11/16 (4.7-17.4) Model Fl Res 44 & 58 Recessed HSW/F2 M. Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°F,8°C) Intermediate Temp. Rating (175°F1790C) Top of Deflector to Ceiling (mm) Spacing Inch Minimum Ft (m) Flow GPM (Llmln) Pressure PSI (bar) Flow GPM (Llmin) Pressure PSI (bar) 12 x 12(3,6 x 3,6) 12(3,6) 12(45,4) 7.5(0,52) 12(45,4) 7.5(0,52) 4 to 6(100 to 152): 1/2(13)recessed using F2 escutcheon 8(2,4) 14 x 14(4,3 x 4,3) 14(4,3) 14(53,0) 10.2(0,71) 14(53,0) 10.2(0,71) 16 X 16(4,9 x 4,9) 16(4,9) 16(60,6) 13.3(0,92) 16(60,6) 13.3(0,92) 16 x 18(4,9 x 5,5) 16(4,9) 18(68,1) 16.8(1,16) 18(68,1) 16.8(1,16) 18 x 18(5,5 x 5,5) 18(5,5) 19(72,0) 18.7(1,29) 19(72,0) 18.7(1,29) 16 x 20(4,9 x 6,1) 16(4,9) 23 (87,1) 27.4 (1,89) 23 (87,1) 27.4 (1,89) 12 x 12(3,6 x 3,6) 12(3,6) 14(53,0) 10.2(0,71) 14(53,0) 10.2(0,71) 6t0 12 (152 to 305): ½(13) recessed using F2 escutcheon 14 x 14 (4,3 x 4,3) 14(4,3) 16(60,6) 13.3(0,92) 16 (60,6) 13.3(0,92) 16 x 16(4,9 x 4,9) 16(4,9) 17 (64,4) 15.0 (1,04) 17(64,4) 15.0(1,04) 16 x 18 (4,9 x 5,5) 16(4,9) 20 (75,7) 20.7(l.43) 20 (75,7) 20.7(l.43) 16 x 20(4,9 x 6,1) 16(4.9) 23(87,1) 27.4(1,89) 23(87,1) 27.4(1,89) For Ceiling types refer to NFPA 13, 13R or 13D Technical Data: Fl Res 58 HSW & HSW/F2 (SIN R3533) Escutcheon, F2, Data: Nominal Max. Sprinkler Max. Sprinkler Ambient K Length Ty Adjustment Face of Fitting Thread Orifice to wall Pressure Temp. Rating Size Inch Temp. Factor Inch Inch (mm) Inch (mm) ___________ __ psi (bar) (mm) °F I °C OF I °C (mm) ______ 3/16-11/16 ½' NPT 155 I 68 100 38 F2 1/2 (13) '/2(13) 175 (12) (R½) 175 I 79 150 I 66 5.8(83.5) 2.45(62) (4.7- 17.4) Ordinary Temp. Rating Intermediate Temp. Rating Top of Deflector to Minimum Max. Coverage area Max. Spacing (155°FI8°C) (175°F179°C) Ceiling Spacing Flow Pressure Flow Pressure Ft x Ft (m x m) Ft (m) Inch (mm) Ft (m) GPM (L/min) PSI (bar) GPM (L/min) PSI (bar) 12 x 12(3,6 x 3,6) 12(3,6) 16(60,6) 7.6(0,53) 16 (60,6) 7.6(0,53) 4 to 6(100 to 152): 14 x 14(4,3 x 4,3) 14(4.3) 18(68,2) 9.7(0,69) 18(68,2) 9.7 (0,69) 16 x 16(4,9 x 4,9) 16(4,9) 21(79,5) 13.2(0,91) 21(79,5) 13.2(0,91) 1/2(13)recessed using F2 escutcheon 16 x 18(4,9 x 5,5) 16(4,9) 25(94,7) 18.6(1,28) 25(94,7) 18.6(1,28) 8(2,4) 16 x 20 (4,9 x 6, 1) 16(4,9) 29(109,8) 25.0(1,73) 29(109,8) 25.0(1,73) 12 x 12(3,6 x 3,6) 12(3,6) 22 (83,3) 14.4(1,0) 22 (83,3) 14,4(1,0) 6t0 12(152t0305): 1/2(13)recessed 14x 14(4,3x4,3) 14(4,3) 22(83,3) 14.4(1,0) 22(83,3) 14.4(1,0) 16 x 16(4,9 x 4,9) 16(4,9) 26(98,4) 20.1 (1,39) 26(98,4) 20.1 (1,39) using F2 escutcheon 16 x 18 (4,9 x 5,5) 16(4,9) 31(117,4) 28.6(1,97) 31(117,4) 28.6(1,97) FCeiling types refer to NFPA 13, 13R or 13D 7. ' Model Fl Res 44 SWC * Not listed for corrosion resistance. Technical Data- F1 Rps 44 SWC (SIN Ic, 12' (101.60mm Th 304.80mm) Fow Of ToW,,II0,rnejon PLISH ON COMER THEN nGHr AGAINST WALL. X 112' Reducer -7 Recowded W.11 Hot@ 2 5115- Oa TURN COLLAR UNTIL TIGHT AGAINST $PRmKLER WRENCH BOSS, I/2 21132, 'J5m07 Fl RES 44 SWC Fig. 6 Thread Nominal Max. Cover Temp. Max. Ambient K Sprinkler Size Orifice Pressure Rating P. Factor Length Inch (mm) psi (bar) Inch (mm) OF I ½" NPT (R½) 3/8" (10) 175 (12) °F E57 135 100 38 4.4(63) 2.45 (62) Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155- 80C) Top of Deflector to Ceiling Inch (mm) Minimum Spacing Ft (m) Flow GPM (Ifmin) Pressure PSI (bar) 12 x 12(3,6 x 3,6) 12(3.6) 13(49,2) 8.7(0,60) 4t06(100t0 152); 1/2 (13) recessed using F2 escutcheon 8(2,4) 14 x 14(4,3 x 4,3) 14(4,3) 14(53,0) 10.2 (0,71) 16 x 16(4,9 x 4,9) 16(4,9) 17(64,3) 15.0(1,1) 16 x 18 (4,9 x 5,5) 16(4,9) 19(71,8) 18.7(1,13) 16 x 20(4,9 x 6,1) 16(4,9) 23(87,1) 27.4(1,89) 12 x 12(3,6 x 3,6) 12(3,6) 14(52,9) 10.2(0,71) 6t0 12 (152t0 305); ½ (13) recessed using F2 escutcheon 14x 14(4,3x4,3) 14(4,3) 15 (56,7) 11.7(0,81) 16 x 16(4,9 x 4,9) 16(4,9) 18(68,1) 16.8(1,16) 16 x 18 (4,9 x 5,5) 16(4,9) 20(75,6) 20.7(1,43) For Ceiling types refer to NFPA 13, 13R or 13D 1-4 Technical Data: Fl Res 58 HSWX (SIN RA3533) Thread Nominal Max. Sprinkler Max. Ambient K Sprinkler Sprinkler Size Orifice Pressure Temp. Rating Temp. Factor Length Identification Inch (mm) psi (bar) Inch (mm) °FI°C Number (SIN) OF bc Bulb ½" NPT (R½) 1/2" (13) 175(12) 155 175 68 I 79 100 150 38 I 66 5.8(83.5) 2.45(62) RA3533 Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°FI8°C) Intermediate Temp. Rating (175°FC) Top of Deflector to Ceiling Inch (mm) PSI (bar) Minimum Spacing Ft (m) Flow GPM (1/mm) Pressure PSI (bar) Flow GPM (L/min) Pressure 18 x 20 (5,5 x 6, 1) 18(5,5) 30(114) 26.8(1,85) 30(114) 26.8(1,85) 4 to 6(100 to 152): ½ (13) recessed using F2 escutcheon 8(2,4) 20x20(6,1 x6,1) 20(61) 30(114) 26.8(1,85) 30(114) 26.8(1,85) 16 x 22(4,9 x 6,7) 16(4,9) 33(125) 32.4(2,23) 33(125) 32.4 (2,23) 16 x 24(4,9 x 7,3) 16(4.9) 38(144) 42.9(2,96) 38(144) 42.9(2,96) 14 x 26(4,3 x 7,9) 14(4.3) 42(160) 52.4(3,75) 42(160) 52.4 (3,75) 18 x 20 (5,5 x 6, 1) 18(5,5) 35(133) 36.4(2,5) 35(133) 36.4 (2.5) 6 to 12 (152 to 305); ½ (13) recessed using F2 escutcheon 16 x 22(4,9 x 6,7) 16(4,9) 38(144) 42.9(2,96) 38(144) 42.9(2,96) 16 x 24(4,9 x 7,3) 16(4,9) 42(160) 52.4(3,6) 42(160) 52.4(3,6) 14 x 26(4,3 x 7,9) 14(4,3) 46(174) 62.9(4,34) 46(174) 62. _K34) For Ceiling types refer to NFPA 13, 13R or 13D Model Fl Res 58 HSWX (Bulb) FACE OF RilING TO I WALL DIMENSION _ 7 11/76" MIN. 2 7/4" HOLE 0L4. (31.8mm) CEILING TO (5 7.2mm) (3. DIMENSION DEFLECTOR I" X 1/2" REDUCER '_ 2 27132" D14. TURN COLLAR UNTIL lIGHT AGAINST SPRINKLER WRENCH BOSS. IJ5PGO8 ADJUSTMENT Fl RES 58 HSWX Fig. 7 Model KRes58 HSWX (Link) EJ Technical Data: KRes58 HSWX (RA3593) Thread Nominal Max. Max. Ambient K Sprinkler Sprinkler Size Orifice Pressure Temp. Factor Length Identification Inch (mm) psi (bar) Inch (mm) Number (SIN) OF I Link ______ ½' NPT (R½) 1/2 (13) 175 (12) 100 38 5.8 (83.5) 2.45 (62) RA3593 Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (165°F/74°C) Top of Deflector to Ceiling Inch (mm) Minimum Spacing Ft (m) Flow GPM (L/mln) Pressure PSI (bar) 18 x 20 (5,5 x 6, 1) 18(5,5) 29(109) 25(1,72) 4 to 6(100 to 152): ½ (13) recessed using F2 escutcheon 8(2.4) 20 x 20 (6,1 x 6, 1) 20(6,1) 30(114) 26.8(1,85) 16 x 22(4,9 x 7,3) 16(4,9) 33(125) 32.4(2,23) 16 x 24 (4,9 x 7,3) 16(4,9) 38(144) 42.9(2,96) 14 x 26 (4,3 x 7,9) 14(4,3) 42(160) 52.4(3,75) 18 x 20(5,5 x 6,1) 18(5,5) 35(133) 36.4(2,5) 6 to 12 (152 to 305): ½ (13) Recessed using F2 escutcheon 16 x 22(4,9 x 6,7) 16(4,9) 38(144) 42.9(2,96) 16 x 24(4,9 x 7,3) 16(4.9) 42(160) 52.4(3,6) 14 x 26(4,3 x 7,9) 14(4,3) 46(174) 62.9(4,34) For Ceiling types refer to NFPA 13, 13R or 13D Maintenance Model Fl Res 30, 49, Fl Res 58, Fl Res 76 and Fl Res 44 Sprinklers should be inspected and the sprinkler sys- tem maintained in accordance with NFPA 25, 13, 13D, and 13R. Do not clean sprinkler with soap and water, Am- monia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non-operation. Model Fl Res 30, 49 & 58 Pendent Sprinkler Specifications Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential pendent sprin- klers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's installation guide- lines and the applicable installation standard. Deflector- to-ceiling distance listing shall be 1" to 8" maximum, only for F1 Res 49. Sprinkler frame and deflector shall be of bronze frame construction having a ½" NPT thread. Wa- ter seal assembly shall consist of a Teflon* coated Bel- leville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (680C)] [175°F (790C)]. Sprinklers shall have a nominal K-factor of 3.0, 4.9 and 5.8. Standard finish: [Bronze] [Chrome- plated] [White Polyester] [Special finish- specify]. Resi- dential pendent sprinklers shall be Reliable Model Fl Res 30, 49 & 58, SIN R3511, R3516 & R3513 (Bulletin 135). Model Fl Res 49 & 58 Recessed Pendent/Fl, Model Fl Res 30,49 & 58 Recessed Pendent/ F2, Model Fl Res 30,49 & 58 Recessed Pendent( FP Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential recessed pen- dent sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's in- stallation guidelines and the applicable installation stan- dard. Deflector-to-ceiling distance listing shall be 1" to 8" maximum, only for F1 Res 49. Sprinkler frame and deflec- tor shall be of bronze frame construction having a 1/2" NPT thread. Water seal assembly shall consist of a Teflon* coated Belleville spring washer with top-loaded extruded *DuPont Registered Trademark 10. or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (68°C)] [175°F (790C)]. Sprinklers shall have a nomi- nal K-factor of 3.0, 4.9 & 5.8. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish— spec- ify]. Recessed escutcheon assembly shall be a steel, two-piece escutcheon [with ½" adjustment (Model F2)] [with 34" adjustment (Model Fl)] [of push-on and thread off design with ½" adjustment (Model FP)]. Standard fin- ish shall be [brass][bright chrome] [white painted]. Resi- dential recessed pendent sprinklers shall be Reliable [Model Fl Res 30, 49 & 58 Recessed Pendent/Fi] [Model Fl Res 30,49 & 58 Recessed Pendent/F2] [Model Fl Res 30,49 & 58 Recessed Pendent/FP] SIN R3511, R3516 & R3513 (Bulletin 135). Model Fl Res 30, 49 & 58 CCP Pendent (Concealed) Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential concealed sprinklers engineered to provide a minimum design den- sity of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be in- stalled in conformance with the manufacturer's installa- tion guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a ½" NPT thread. Water seal as- sembly shall consist of a Teflon* coated Belleville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of 155°F (68°C). Cover plate assem- bly shall consist of a brass cover plate and copper alloy retainer flange. Method of attaching the cover plate to the sprinkler cup shall be a push-on and thread-off design allowing a ½" cover plate adjustment. Cover plate tem- perature rating shall be 135°F (570C). A plastic protec- tive cap shall be provided and factory installed inside the sprinkler cup to protect the sprinkler from damage, which could occur during construction before the cover plate is installed. Standard cover plate finish: [White] [Custom Color— specify]. ]. Concealed pendent sprinklers shall be Reliable Model Fl Res 30, 49 & 58 CCP, SIN R3511, R3516 & R3513 (Bulletin 135). Model Fl Res 44, Fl Res 58 Horizontal Sidewall, Fl Res 58 HSWX & KRes58 HSWX Residential Sprinkler Specifications Sprinklers shall be [cULus Listed] low flow residential horizontal sidewall sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manu- facturer's technical data sheets are to be used. Residen- tial sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a ½" NPT thread. Water seal assembly shall consist of a Teflon* coated Bel- *DuPont Registered Trademark 11. leville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (680C)] [175°F (79°C)]. The solder element (Link) version, the water seal consist of a cap with a bellville spring washer and a temperature rating of 165°F (740C). The recessed assembly forthe HSWX (Bulb & Link) should be a steel two pieces escutcheon with 1/2" adjustment (Model F2) standard finish should be Bright Chrome and white paint- ed. The Fl Res 58 HSW is also available with low lead frame. Fl Res 58 HSW and HSWX sprinklers shall have a nominal K Factor of 5.8 and Fl Res 44 a nominal K factor of 4.4. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish— specify]. Residential horizontal sidewall sprinklers shall be Reliable Model Fl Res 44, Fl Res 58, Fl Res 58 HSWX & Model KRes58 HSWX, SIN R3531, RA3533 & RA3593 (Bulletin 135). Model Fl Res 44 Recessed Horizontal Sidewall Sprinkler Use description for the Model Fl Res 44 horizontal side- wall sprinkler with the following modifications: Replace "horizontal sidewall sprinkler" with "recessed horizontal sprinkler." Add: Recessed escutcheon assembly shall be a steel, two-piece escutcheon with ½" adjustment (Model F2). Standard finish shall be [brass][bright chrome] [white painted] [Special finish— specify]. Residential recessed horizontal sidewall sprinklers shall be Reliable Model Fl Res 44/F2, SIN R3531 (Bulletin 135). Model Fl Res 76 Pendent Sprinklers shall be [cULus Listed] low flow residential pendent sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprin- klers shall be installed in conformance with the manufac- turer's installation guidelines and the applicable installa- tion standard. Sprinkler frame and deflector shall be of bronze frame construction having a 34" NPT thread. Wa- ter seal assembly shall consist of a Teflon* coated Bel- leville spring washer with machined or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (680C)] [175°F (790C)]. Sprinklers shall have a nominal K-factor of 7.6. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Spe- cial finish— specify]. Residential pendent sprinklers shall be Reliable Model Fl Res 76, SIN R7618 (Bulletin 135). Model Fl Res 76 Recessed Pendent/171, Model Fl Res 76 Recessed Pendent/F2, Model Fl Res 76 Recessed Pendent/FP Sprinklers shall be [cULus Listed] low flow residential recessed pendent sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manu- facturer's technical data sheets are to be used. Residen- tial sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a 3/4" NPT thread. Water seal assembly shall consist of a Teflon* coated Bel- leville spring washer with machined or cold head cup with 3 mm glass bulb containing no plastic parts, and hav- ing a temperature rating of [155°F (680C)] [175°F (790C)]. Sprinklers shall have a nominal K-factor of 7.6. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Spe- cial finish— specify]. Recessed escutcheon assembly shall be a steel, two-piece escutcheon [with ½" adjust- ment (Model F2)] [with 3%" adjustment (Model Fl)] [of push-on and thread off design with ½" adjustment (Mod- el FP)]. Standard finish shall be [brass][bright chrome] [white painted]. Residential recessed pendent sprinklers shall be Reliable [Model Fl Res 76 Recessed Pendent/ Fl] [Model Fl Res 76 Recessed Pendent/F2] [Model Fl Res 76 Recessed Pendent/FP] SIN R7618 (Bulletin 135). Model Fl Res 76 CCP Pendent (Concealed) Sprinklers shall be [cULus Listed] low flow residential concealed sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprin- klers shall be installed in conformance with the manufac- turer's installation guidelines and the applicable installa- tion standard. Sprinkler frame and deflector shall be of bronze frame construction having a 3/4" NPT thread. Wa- ter seal assembly shall consist of a Teflon* coated Bel- leville spring washer with machined or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of 155°F (680C). Cover plate assem- bly shall consist of a brass cover plate and copper alloy retainer flange. Method of attaching the cover plate to the sprinkler cup shall be a push-on and thread-off design allowing a ½" cover plate adjustment. Cover plate tem- perature rating shall be 135°F (570C). A plastic protec- tive cap shall be provided and factory installed inside the sprinkler cup to protect the sprinkler from damage, which could occur during construction before the cover plate is installed. Standard cover plate finish: [White] [Custom Color— specify]. ]. Concealed pendent sprinklers shall be Reliable Model Fl Res 76 CCP, SIN R7618 (Bulletin 135). Finishes (1) Standard Finishes Sprinkler F1, F2, IFIR Cover Plates Escutcheons Bronze Brass White Painted Chrome Plated Bright chrome Plated Chrome White and Black White Painted Polyester(2) Coated Special Application Finishes Sprinkler Fl, F2, FP Escutcheons Electroless Nickel PTFE(Teflon®)(2) Electroless Nickel PTFE (Teflon) Bright Brass Bright Brass Black Plated Black Plated Black Paint Black Paint Off White Off White Chrome Dull Chrome Dull Other finishes and colors are available on special order. Consult factory for details. cULus listed Corrosion Resistant Note: Paint or any other coating applied over the factory finish will void all approvals and warranties. Ordering Information Specify: Sprinkler Model Sprinkler Type Temperature Rating Sprinkler Finish Escutcheon Finish Cover Plate Finish *DuPont Registered Trademark The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by Reliable Automatic Sprinkler Co., Inc. - Recycled Rel ® (800) 431-1588 Sales Offices Paper (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 06/15 P/N 9999970235 Pendent Fl/F2 r,. El Upright Pendent Horizontal Sidewall Conventional Vertical Sidewall Recessed Pen dent/Fl/F2 Recessed Conceale Recessed Horizontal Sidewall Pendent Pendent/FP XLH Upright XLH Pendent & ./ -.., 'S . \f fJ20 Bulletin 014 Rev. N - - b1le. ® Model Fl FR Series Hefla Quick Response Glass Bulb Sprinklers I, Model Fl FR56 Sprinkler Types Standard Spray Upright Standard Spray Pendent Conventional Upright/Pendent Vertical Sidewall Horizontal Sidewall Model Fl FR56 Recessed Sprinkler Types Standard Spray Pendent Horizontal Sidewall Model Fl FR56 Concealed Sprinkler Types Standard Spray Pendent Model Fl FR42, Fl FRXLH & Fl FR28 Sprinkler Types Standard Spray Upright Standard Spray Pendent Model Fl FR40 Sprinkler Types Standard Spray Pendent Model Fl FR42, Fl FR40, Fl FRXLH & Fl FR28 Recessed Sprinkler Types Standard Spray Pendent Model Fl FR56LL & Fl FR42LL NSF Certified Low Lead Sprinkler Types Standard Spray Pendent with less than 0.25% Lead Content Listing & Approvals The following organizations provide Listings or Approvals for various Model Fl FR series sprinklers. See the Design and Installation table in this Bulletin for information on specific listings and approvals applicable to each sprin- klr Underwriters Laboratories Inc. and Certified for Product Description Canada (cULus). Reliable Model F1FR series sprinklers FM Approvals (FM) are quick-response automatic sprin- Loss Prevention Certification Board (LPCB) klers with a glass bulb thermal element, VdS SchadenverhUtung GmbH (VdS) Model F1FR series sprinklers are Stan- NSF Certified to NSF/ANSi Standard Al Ann dard Spray sprinklers, with the excep- ' (NSF) ' tion of the Model F1 FR56 Conventional XLH Recessed 6. EC Certificate: 0786-CPD-40239 (RA1414), 0786- sprinkler which is an Old-style/Conven- PendentFP CPD-40251 (RA1425), 0786-CPD-40252 (RA1475) tional sprinkler. (EC) The Model F1FR Series automatic sprinklers utilize a 3.0 UL Listing Category mm frangible glass bulb. These sprinklers have demonstrat- Sprinklers, Automatic & Open (VNlV) ed response times in laboratory tests which are five to ten Quick Response Sprinkler times faster than standard response sprinklers. This quick response enables the Model Fl FR Series sprinklers to apply water to a fire faster than standard-response sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely man- ufactured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as the liq- uid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. Model Fl FR Series sprinklers provide a wide range of op- tions where quick-response, glass bulb sprinklers are used: Pendent, recessed pendent, upright, horizontal side- wall, and vertical sidewall deflectors K-factors of 2.8 (40 metric), 4.0 (57 metric), 4.2 (60 metric), and 5.6 (80 metric) Flush, recessed, and concealed installations See the Design and Installation Information table in this Bulletin for information on the approvals and availability of specific Model Fl FR series sprinkler configurations. Model F1FR Recessed Pendent and Recessed Horizon- tal Sidewall sprinklers are required to be used with Reliable Model Fl, F2, or FP recessed escutcheons. See the Re- cessed Escutcheon Data table in this Bulletin for listing and approval information with each specific Model F1FR series sprinkler. Model Fl and F2 recessed escutcheons, shown in Fig. 1 and 3, are a friction fit assembly allowing for 3/4-inch (19mm) and 1/2-inch (12.7mm) of adjustment, respectively. Model FP recessed escutcheons, shown in Fig. 2, provide a 1/2-inch (12.7mm) threaded adjustment. Model Fl FR56 Concealed Pendent and Model Fl FR56LL Concealed Pendent sprinklers are required to be used with Model CCP cover plates. A standard profile Model COP cov- er plate is available that provides up to 1/2-inch (12.7mm) of cover plate adjustment. In addition, a low profile Model CCP cover plate is also available that provides up to 5/16-inch (8.0mm) of cover plate adjustment. See the Design and In- stallation Information and Listed and Approved Temperature Ratings tables in this Bulletin for further information on ap- proved cover plate options. Application Model F1FR Series sprinklers are intended for use in accordance with NFPA 13, FM Property Loss Prevention Data Sheets, and the requirements of the Authority Hav- ing Jurisdiction. Care must be exercised that the k-factor, temperature rating, deflector style, and sprinkler type are in accordance with the requirements of the applicable design and installation standards. In addition, Model F1FR Series sprinklers must be used in accordance with their listings and approvals, as well as the information provided in this Bulletin. Installation Glass bulb sprinklers have orange bulb protectors or pro- tective caps to minimize bulb damage during shipping, han- dling and installation. Reliable sprinkler installation wrench- es are designed to install sprinklers with bulb protectors in place. Remove the bulb protector at the time when the sprin- kler system is placed in service for fire protection. Removal of the bulb protector before this time may leave the bulb vul- nerable to damage. Remove bulb protectors by undoing the clasp by hand. Do not use tools to remove bulb protectors. 2. Model F1FR Series sprinklers must be installed with the Reliable sprinkler installation wrench identified in the Design and Installation Information table in this Bulletin. Any other wrench may damage the sprinkler. A leak tight sprinkler joint can be obtained with a torque of 8 to 18 lb-ft (11 to 24 N-m). Do not tighten sprinklers over the maximum recommended installation torque. Exceeding the maximum recommended installation torque may cause leakage or impairment of the sprinkler. Recessed Sprinklers Model Fl FR Series Recessed sprinklers are to be installed as shown in Fig. 1 Fig. 2, or Fig. 3, as applicable to the spe- cific model being installed. The Recessed Escutcheon Data table in the Bulletin identifies the only recessed escutcheons that are permitted to be used with each Model Fl FR Series Recessed sprinkler. The use of any other recessed escutch- eon will void all approvals and negate all warranties. Concealed Sprinklers Model F1FR Series Concealed Pendent sprinklers are to be installed as shown in Fig. 4 or Fig. 5, as applicable to the selected cover plate. Model Fl FR56 Concealed Pendent and Model Fl FR56LL Concealed Pendent sprinklers have a factory-installed Model CCP cup. A protective cap is in- stalled at the factory that should remain on the sprinkler until the sprinkler is installed and should then be reinstalled on the sprinkler until the cover plate is installed. The concealed sprinkler assemblies are completed by the installation of a Model CCP push-on/thread-off cover plate assembly. The cover plate and sprinkler cup assemblies are joined using a cover plate skirt with flexible tabs for threaded engage- ment. A choice of two Model CCP cover plate assemblies provides either 1/2-inch (13mm) or 5/8-inch (8mm) of cover adjustment. Do not install Model F1FR Series Concealed Pendent sprinklers in ceilings which have positive pressure in the space above. Model F1FR Series Concealed Pendent sprinklers require a 2-5/8-inch (67mm) diameter hole to be cut in the ceiling. The Model RC1 wrench is used to engage the sprinkler wrenching surfaces and to install the sprinkler in the fitting. Remove the protective cap to install the sprinkler, then reinstall the protective cap until the cover plate is installed, When inserting or remov- ing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. Do not wrench any other part of the sprinkler/cup assembly. Installation is com- pleted by removing the protective cap from the sprinkler and pushing the cover plate onto the cup. Final adjustment is made by hand turning the cover plate until the skirt flange makes full contact with the ceiling. Cover plate removal requires turning the cover plate in the counter clockwise direction. After installation, inspect all sprinklers to ensure that there is a gap between the cover plate and ceiling and that the four cup slots are open and free from any air flow impediment to the space above. Concealed cover plate/cup assemblies are listed only for use with specific sprinklers. The use of any concealed cover plate/cup assembly other than the Reliable Model COP with Model Fl FR56 Concealed Pendent and Model Fl FR56LL Concealed Pendent sprinklers or the use of the Model CCP Concealed cover plate assembly on any sprinkler with which it is not specifically listed my prevent good fire protection and will void all guarantees, warranties, listings and approvals. Technical Data: Sensitivity: Quick-response Thread Size: 1/2-inch NPT standard; ISO 7-R1/2 optional Maximum Working Pressure: 175 psi (12 bar) - 100% Factory tested hydrostatically to 500 psi (34.5 bar) SIN RA1425, RA1414 & RA1435 cULus listed for 250 psi (17 bar) Design and Installation Information Model Nominal K-factor Nominal Orifice Diameter Deflector! Orientation Nominal Sprinkler Height Installation Wrench SIN I mm Listings and Approvals Approval Notes US Metric inches mm inches F1FR28 2.8 40 3/8 10 Pendent 2.25 57 0 RA1411 cULus 2 Recessed Pendent 2.25 57 GFR2 RA1411 cULus 2 Upright 2.25 57 D RA1421 cULus 1,2 F1FR40 4.0 57 3/8 10 Pendent 2.25 57 D RA1418 VdS Recessed Pendent 225 57 GFR2 RA1418 VdS F1FR42 4.2 60 7/16 10 Pendent 225 57 D RA1413 cULus 2 Recessed Pendent 225 57 GFR2 RA1413 cULus 2 Upright 2.25 57 D RA1423 cULus 1,2 F1FR42LL 4.2 60 7/16 10 Pendent 2.25 57 D RA1410 cULus, NSF Recessed Pendent 225 57 GFR2 RA1410 cULus, NSF F1FRXLH (F1FR42 with Pintle) 4.2 60 7/16 10 Pendent 225 1 57 0 IRA1413 cULus 2 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 Upright 2.25 57 D RA1423 cULus 1,2 F1FR56 5.6 80 1/2 15 Pendent 2.25 57 D RA1414 cULus FM , , LPCB, VdS, EC 1,2,3,4 Recessed Pendent 2.25 57 GFR2 RA1414 cULus, FM, LPCB, VdS, EC 1,2,3,4 Concealed Pendent 2.25 57 RC1 RA1414 cULus,VdS,EC 5,6 Upright 2.25 57 D RA1425 cULus, FM, LPCB, VdS, EC 1,2,3,4 Conventional (Pendent or Upright)" 2.25 57 D RA1475 LPCB, VdS, EC 4 F1FR56LL 5.6 80 1/2 15 Pendent 2.25 57 D RA1415 cULus, NSF 1 Recessed Pendent 2.25 57 GFR2 RA1415 cULus, NSF Concealed Pendent 2.25 57 RC1 RA1414 cULus, NSF 6 F1FR56 5.6 80 1/2 15 Horizontal Sidewall 2.63 67 D RA1435 cULus, FM 1,2,3,7 Recessed Horizontal Sidewall 2.63 67 GFR2 __ RA1435 cULus, FM 8 F1FR56 5.6 80 1/2 15 Vertical Sidewall (Pendent or Upright) 57 D cULus, FM,2.25 rRA1485 LPCB 1,2,3,9 cULus Listed Corrosion Resistant sprinkler when ordered with available Polyester coating. cULus Listed Corrosion Resistant sprinkler when ordered with available Electroless Nickel PTFE plating. Available with FM approved Polyester coating in black or white. Available with LPCB and VdS approved Polyester coating. VdS and EC approvals of the F1FR56 Concealed Pendent sprinkler are for 155°F (68°C) temperature rated sprinklers only. VdS approved sprin- klers must use Norbulb brand glass bulbs with the 1/2-inch (12.7mm) adjustment Model CCP cover plate only. (8) Model Fl FR56 Concealed Pendent and Model Fl FR56LL Concealed Pendent sprinklers must be used with Reliable Model COP cover plates, available as either standard depth with 1/2-inch (12.7mm) of adjustment or low profile with 5/16-inch (8.0 mm) of adjustment. cULus Listing of the F1FR56 Horizontal Sidewall sprinkler is for Light and Ordinary Hazard occupancies only. FM Approval of the F1FR56 Hori- zontal Sidewall sprinkler is for Light Hazard occupancies only. cULus Listing and FM Approval of the F1FR56 Recessed Horizontal Sidewall sprinkler is for Light Hazard occupancies only. The Fl FR56 Vertical Sidewall sprinkler is listed and approved for use only in Light Hazard occupancies. Minimum to maximum deflector to ceil- ing distance shall be 4 inches to 12 inches (102mm to 305mm). LPCB approval of the F1FR56 Vertical Sidewall sprinkler is for installation in the Pendent position only. 3. Listed and Approved Temperature Ratings Model Deflector, Orientation Ordinary Temp. Classification 100°F (38°C) Max. Ambient Temp. Intermediate Temp. Classification 150°F (65°C) Max. Ambient Temp. High Temp. Classification 225°F (1 07°C) Max. Ambient Temp. 135°F (57°C) Temp. Rating 155°F (68°C) Temp. Rating 175°F (79°C) I Temp. Rating 200°F (93°C) Temp. Rating 286°F (141°C) Temp. I Rating Orange Bulb Red Bulb Yellow Bulb Green Bulb Blue Bulb Pendent cULus F1FR28 Recessed Pendent cULus I -- _________ Upright cULus F1FR40 Pendent VdS Recessed Pendent VdS I -- Pendent cULus F1FR42 Recessed Pendent cULus I -- _________ Upright cULus F1FR42LL ________ Pendent Recessed Pendent -- -- cULus, NSF cULus, NSF -- -- Pendent cULus F1FRXLH Recessed Pendent cULus I -- _________ Upright cULus Pendent cULus, FM, LPCB, VdS, EC Recessed Pendent cULus, FM, LPCB, VdS, EC -- Fl FR56 Concealed Pendent* cULus cULus,VdS,EC I cULus -- Upright cULus, FM, LPCB, VdS, EC Conventional (Pendent or Upright)' LPCB VdS EC Pendent -- cULus, NSF -- Fl FR56LL Recessed Pendent -- cULus, NSF -- _________ Concealed Pendent* -- cULus, NSF -- Horizontal Sidewall cULus, FM F1FR56 _______________ Recessed Horizontal Sidewall cULus, FM -- F1FR56 Vertical Sidewall (Pen- dent _or_Upright) cULus, FM, LPCB * Model Fl FR56 Concealed Pendent and Fl FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates. For Ordinary Temperature Classification sprinklers use a 135°F (57°C) temperature rated cover plate. For Intermedinte Temperature Classification sprinklers use a 165°F (74°C) temperature rated cover plate. Recessed Escutcheon Data Model Deflector! Orientation Listed and Approved Recessed Escutcheons SIN Model Fl (Fig.1&3) 3/4-inch (19mm) adjustment Model F2 (Fig.1&3) 1/2-inch (12.7mm) adjustment Model FP (Fig. 2) 1/2-inch (12.7mm) adjustment F1FR28 Recessed Pendent cULus cULus cULus RA1411 F1FR40 Recessed Pendent VdS VdS VdS RA1418 F1FR42 Recessed Pendent cULus cULus cULus RA1413 FlFR42LL Recessed Pendent cULus, NSF cULus, NSF cULus, NSF RA1410 F1FR42XLH Recessed Pendent cULus cULus cULus RA1413 F1FR56 Recessed Pendent cULus, LPCB, VdS, EC cULus, FM, LPCB, VdS, EC cULus, VdS, EC RA1414 F1FR56LL Recessed Pendent cULus, NSF cULus, NSF cULus, NSF RA1415 F1FR56 Recesced Horizontal Sidewall cULus cULus, FM cULus RA1435 4. T TURN COLLAR UN1IL TIGHT AGAINST SPRINKLER WRENCH BOSS F! ESCUTCHEON 3/4"[l9mm] ADJUSTMENT F2 ESCUTCIIEQJ/ I/2"[12.7mm/ ADJUSTMENT FACE OF FITTING TO PACE OF CEILING DIMENSION Fl ESCUTCHEON AT MAXIMUM RECESS = 1 "[25.4mm] AT MINIMUM RECESS = 3/8'[9.5mm] / P2 ESCUTCHEON AT MAXIMUM RECESS = 3/4"(l9mm] AT MINIMUM RECESS = 3/8"[9.5mm] F! ESCUTCHEON I AT MAXIMUM RECESS = 7/8"[22.2mm] MINIMUM RECESS = 1-5/8 "[41.3mm] ESCUTCHEON AT MAXIMUM RECESS = 1- 1/8 [28.6mm] AT MINIMUM RECESS = 1-5/8 '[41.3mm] 1-1g. 1 Model Fl FR56, El FR56LL, El FR42, Fl FR40, Fl FR42LL, Fl FRXLH & Fl FR28 Recessed Pendent sprinkler with Model El or F2 escutcheon 1" X 1/2" REDUCER 2 5/8" 0/A. [66.7mm] tr HOLE IN CEILING 2 5/16" 0/A. [58.7mm] CU!-' FACE OF FITTING OMNI TO FACE OF CEILING DIMENSION AT MAXIMUM RECESS = 1-1/2 "[38mm] CEILING AT MINIMUM RECESS = 1 "[25.4mm] AT MINIMUM RECESS = 1 "[25.4mm] 12 "[12.7mm] J AT MAX/MUM RECESS = 9/16"/'14.3mm] ADJUSTMENT 31/4"DIA. [82.6mm] Fig. 2 Model F1FR56, F1FR56LL, F1FR42, F1FR40, F1FR42LL, F1FRXLH & E1FR28 Recessed Pendent sprinkler with Model FP escutcheon 5. FACE OF FITTING TO FACE OF CEILING DIMENSION Fl ESCUTCHEON AT MAXIMUM RECESS = 1 "[25.4mm] AT MINIMUM RECESS = 3/8 "[9.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 3/4 "[l9mmj AT MINIMUM RECESS = 3/8[9.5mm3 F? ESCUTCHEON I7A AT MAXIMUM RECESS = 1-3/8"[34.9mm] AT MINIMUM RECESS = 2- 1/16[52.4mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 1-5/8"[4 1.3mm] AT MINIMUM RECESS = 2-1/16"[52. 4mm] 2 1/4" HOLE 0/A. -k-,/8" 157.2mmj [3.2mm] 1" X 1/2" REDUCER 7- #--- 15116" DIA.4./j I [49.2mm] 11111 I I TURN COLLAR UNTIL - TIGHT AGAINST SPRINKLER WRENCH BOSS. 2 27/32" 0/A. [72.2mm] Fl ESCUTCHEON [ 3/4"[l9mm] ADJUSTMENT F2 ESCUTCHEON 1/2712.7mm] ADJUSTMENT V (1) 4"-12" [10 1.6mm-304.8mm] CEILING TO DEFLECTOR RECESSED HSW w/F1 OR F2 ESCUTCHEON OIJFGW (i) FM APPROVED FOR 4" - 6" [101.6MM - 152.4MM] CEILING TO DEFLECTOR WITH F2 ONLY. Fig. 3 Model Fl FR56 Recessed Horizontal Sidewall sprinkler with Model Fl or F2 escutcheon 1" x 1/2" REDUCING ILE OR ELBOW 2 5/16"D/A— HOLE IN CEILING CUP CEILING—' 1/2" MAX. I r--- COVER ADJUSTMENT COVER PLATE - ASSEMBLY 5/16" DIA SPRINKLER 1 1/2" MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION 7 15/16" --- CONCEALED, 1/2" ADJUSTMENT Hg. 4 Model Fl FR56/F1 FR56LL Concealed Pendent sprinkler with standard depth 1/2-inch (12.7mm) adjustment - Model CCP cover plate I" x 1/2" REDUCING TEE OR ELBOW 2 5/16" DIA - HOLE IN CEILING CEILING 5/16" COVER ADJ COVER AS SPRINKLER I CONCEALED, 5Z16" ADJUSTMENT 1 1/2" MAX. FACE OF FITflNG . TO FACE OF CEILING DIMENSION 3/4" OI?FGO2A Fig. 5- Model F1 FR56/F1 FR56LL Concealed Pendent sprinkler with low profile 5/16-inch (8.0mm) adjustment - Model CCP cover plate Maintenance The Model Fl FR Series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Replace any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Finishes (1) Standard Finishes Sprinkler Escutcheon Cover plate111 Bronze Brass Chrome Chrome Plated Chrome White Polyester Plated Coated 0)05 White Painted Special Application Finishes Sprinkler Escutcheon Cover plate111 Electroless Nickel PTFE(7' Electroless Nickel PTFE Bright B rig t Brass Bright Brass(31 Bright Brass Black Plating Black Plated Black Plated Black Paint Black Paint2'1 Black Paint Off White Off White:2104 Off White Satin Chrome Chrome Dull Chrome Dull ') Other finishes and colors are available on special order. Consult the factory for details. Custom color painted sprinklers may not retain their UL Corrosion resistance listing. Coverplate custom paint is semi-gloss, unless specified otherwise. cULus Listed only. 200°F (93"C) maximum. cULus listed 'corrosion resistance" applies to SIN Numbers RA1435 (HSW), RA1485(VSW), RA1425 (Upright), RA1414 (Pendent) and RA1415 (Pendent) in standard black or white. Corrosion resistance in other polycarer colors is available upon request. FM APPIOVs finish as "Polyester coated" applies to SIN Number RA1414, RA i'135 and RA1425 in standard black or white. )6( LPCB and VdS Approved finish applies only to RA1425, RA1414, RA1418 (VdS) and AA1475. '71cULus listed Corrosion Resistant 7 Material Data Frame: DZR Brass, QM Brass, or Low Lead Brass Deflector: CDA Alloy 220, 260, or 510 Load Screw\Pintle: CDA Alloy 360 or 544 Cup: CDA Alloy 651 or 693 Washer: Nickel Alloy 440 or 360, coated with PTFE Adhesive Tape Bulb: Glass Ordering Information Specify: Sprinkler Model: [Fl FR28][F1 FR4O][F1 FR42] [Fl FR42LL][F1 FRXLH][F1 FR56][F1 FR56LL] Sprinkler Deflector/Orientation: [Pendent] [Recessed Pendent] [U prig ht] [Conventional][Horizontal Sidewall] [Recessed Horizontal Sidewall][Vertical Sidewall] Sprinkler threads: [1/2-inch NPT][ISO 7-A 1/2] Sprinkler Temperature Rating: [135°F (570C)][155°F (68°C)][ 175°F (79°C)][200°F (93°C)][286°F (141°C)] Sprinkler Finish Escutcheon Model: [F1][F2][FP] Escutcheon Finish (where applicable) Cover plate Model: [standard profile CCP 1/2-inch (12.7mm) adjustment][low profile CCP 5/16-inch (8.0mm) adjustment] Cover plate Temperature Rating: [135°F (57°C) for use with Ordinary Temperature sprinklers][ 165°F (74°C) for use with Intermediate Temperature sprinklers] Cover plate Finish Note: When Model F1FR Series Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. Reabe...For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Automatic sprinklers Flush automatic sprinklers Recessed automatic sprinklers Concealed automatic sprinklers Adjustable automatic sprinklers Dry automatic sprinklers Intermediate level sprinklers Open sprinklers Spray nozzles Alarm valves Retarding chambers Dry pipe valves Accelerators for dry pipe valves Mechanical sprinkler alarms Electrical sprinkler alarm switches Water flow detectors Deluge valves Detector check valves Check valves Electrical system Sprinkler emergency cabinets Sprinkler wrenches Sprinkler escutcheons and guards Inspectors test connections Sight drains Ball drips and drum drips Control valve seals Air maintenance devices Air compressors Pressure gauges Identification signs Fire department connection The equipment press cd in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research C.r polation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactL.rod and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and rerrabe sprrktor contractors located throughout the United States, Canada and foreign countries. Manufactured by Reliable Automatic Sprinkler Co., Inc. Recycled ® (800) 431-1588 Sales Offices Paper Rai (800)i le 848-6051 Sales Fax Revision lines indicate updated or new data. (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 12/15 P/N 9999970300 Item Description 1 Manifold Body, Male Thread x Male Thread 2 Inline Check Valve, Spring Loaded 3 Flow Switch with Retard 4 Drain Valve, with optional pressure relief valve 5 Pressure Gauge, 0-300 psi 4 National Fire Products, LLC RESI-RISERTM 4, The RESI-RISERTM is a pre-assembled, compact, attractive fire sprinkler riserfirmrrsdecFtiai, sprinkler systems in accordance with NFPA 13, 13R and B.D. The RESI-RISERTM manifold is manufactured as a one- piece casting that is air-tested for leaks. Raised lettering on both sides allows the RESI-RISERTM to be installed to the right or left and easily identifies the flow direction and Test and Drain outlet. Two mounting legs are molded onto the manifold allowing for a secure right or left anchoring. The flow switch has dual SPDT switches and a retard of 0-90 seconds. An optional "all in one" cost saving combination Pressure Relief Valve/Test and Drain Valve is available. The RESI-RISERTM unique design gives the ability to be installed within standard 2 x 4 frame construction. Every size RESl-RISERTM fits within a 2 x 4 wall framed at 16 inches on center. Technical Data Sizes: 1", 1'/4, 1W', and 2" Style: Thread x Thread Listing: Flow Switch and Pressure Gauge are UL Listed Finish (Riser Body): Cast Brass Water Pressure Gauge: 0-300 psi Optional Accessories: 175 psi Pressure Relief Valve/Test and Drain US Patent # 6,076,545 RESI-RISERTM Size Chart Description in 1Y4" 1W' 2" Height* 13" 13" 13" 13" Width** 10-3/4" 11-1/2" 12" 12-1/2- Depth 3-1/2" 3-1/2" 3-1/2" 3-1/2- Drain Size 1/2" 1" 1" 1" Dimensions include all spacing needed to operate drain valve and remove flow switch cover * Without check valve ** With or without pressure relief valve 0 National Fire Products, iic (800) 528-7978 Relieving Pressure xceeding 175 psi 0 10 15 20 25 30 35 40 45 50 55 60 Pressure Loss Tables Pressure Loss in 1" Res!-Riser 12 Pressure Relief/Test and, Drain How it Works Normal Position - Static Pressure 0 10 15 20 25 30 35 40 Flow (gpm) Pressure Loss in 1-1/4" Resi-Riser Flow (gpm) Pressure Loss in 1-1/2" Resi-Riser 10 Manual Open - Drain VA CL 8 or Flow S 6 4 2 ! a. 0 - Locked Clotr :. t., Q 6 5 Hydrostatic e CIL cj5-cZ ) 4 a. 0 0 10 15 2025 30 35 40 45 50 55 60 65 70 75 80 Flow (gpm) Pressure Loss in 2" Resi-Riser 0 15 25 35 45 55 65 75 85 95 Flow (gpm) 35 .5 © National Fire Products, LLC )_ d 6 (800) 528-7978