2708 GATEWAY RD; ; FPC2017-0182
PERMIT REPORT Licity of Carlsbad Print Date: 09/12/2023 Job Address: 2708 GATEWAY RD, CARLSBAD, CA 92009-1730 Permit Type: FIRE-Construction Commercial Work Class: Parcel #: 2132631100 Track #: Valuation: $358,824.65 Lot #: Occupancy Group: . Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Project Title: Description: C3 KIDS CHURCH - UNDERGROUND Applicant: RAOZ GENERAL ENGINEERING INC P0 BOX 3127 SAN DIEGO, CA 92163-1127 (619) 237-7610 Permit No: FPC2017-0182 Status: Closed - Finaled Underground Fire Applied: 06/30/2017 Issued: 08/03/2017 Finaled Close Out: 09/13/2021 Final Inspection: INSPECTOR: Wang, Cindy Fieri, Dominic FEE AMOUNT FIRE Plan Resub (3rd&Subsequent Submittal/hr) $132.00 FIRE Underground Piping with up to 4 Hyds/Risers $733.0 Total Fees: $865.00 Total Payments To Date: $865.00 Balance Due: $0.00 Fire Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov - - INDUSTRIAL FIRE SPRINKLER CO., INC. CA LIC.C-16 558084 HI LIC. C-20351 Co LIC. 11-1058 UT LIC. 7336958-5501 VA LIC. 2705 125390A C3 KIDS CHURCH 2708 GATEWAY ROAD CARLSBAD, CA 92008 HYDRAULIC CALCULATIONS MATERIAL LIST TECH DATA 1. FPC2017-0182 2708 GATEWAY RD 3845 Imperial Ave., San Diego, CA., 92113 • Phone (619) 266-6030 • Fax (619) 266-6035 I-varauIic uaicuiations for Project Name: C3 Kids Church Location: 2708 Gateway Rd., Carlsbad, CA 92008, Drawing Name: Fire Sprinkler Piping Plan.cad Calculation Date: 6/10/2017 Design Remote Area Number: Remote Area Location: Occupancy Classification: Density: Area of Application: Coverage per Sprinkler: Type of sprinklers calculated: No. of sprinklers calculated: Type of System: In-rack Demand Hose Streams: 1 Kids Activity Area Light Hazard 0.10gpm/ft2 1500.00ft2 (Actual 1558.50ft2) 196.00ft2 Upright 17 Wet Volume of Dry or PreAction System: N/A gpm at Node: N/A 100.00 at Node: I Type: Allowance at Source N/A Total Water Required (including Hose Streams where applicable): From Water Supply at Node 1: 518.86 @96.36 Water Supply Information: Name of Contractor: Kingdom Builders Address: 2588 El Camino Real Suite# F337, Carlsbad, CA 92008 Phone Number: 760-855-6331 Name of designer: Freddy Alcaraz Authority Having Jurisdiction:City of Carlsbad Fire Department Notes: 1&I M.E.P.CAD, Inc. AutoSPRlNK® 12 v12.0.61.0 1 6/10/201711:09:02AM Page 1 -- ON Actual .......- Device (gpm) Job Number: 17-872 Report DescriptiorE Light Hazard (1) Minimum Flow (gpm) K-Factor (K) l re (psi) Sprinkler 151 28.52 19.60 5.6 25.93 Sprinkler 152 26.55 19.60 5.6 22.48 Sprinkler 153 25.60 19.60 5.6 20.90 Sprinkler 154 25.69 19.60 5.6 21.05 Sprinkler 155 32.77 19.60 5.6 34.24 Sprinkler 156 27.48 19.60 5.6 24.07 Sprinkler 157 24.59 19.60 5.6 19.29 Sprinkler 158 22.87 19.60 5.6 16.68 Sprinkler 159 22.03 19.60 5.6 15.48 Sprinkler 160 22.11 19.60 5.6 15.59 Sprinkler 161 32.09 1960 5.6 32.83 Sprinkler 162 25.64 19.60 5.6 20.96 Sprinkler 163 21.36 19.60 5.6 14.56 Sprinkler 164 21.93 19.60 5.6 15.33 Sprinkler 165 20.36 19.60 5.6 13.21 c> Sprinkler 166 19.60 19.60 5.6 12.25 Sprinkler 167 19.67 19.60 5.6 12.34 Most Demanding Sprinkler Data , 0 M.E.P.CAD, Inc. jj AutoSPRINK® 12 v12.0.61.0 6/10/2017 11:09:04AM Page 3 IJ I WI 16%1. I JI III I I emote Area Number: 1 Date: 6/10/2017 Pipe Information Elev I Flow added Fittings & Length C Factor Total(Pt) Notes 1ode 1 (Foot) K-Factor this step Nominal ID Devices (Foot) FittinglDevlce (Equivalent Fitting (Foot) Pf Friction Loss Per Unit Elev(Pe) (q) Equiv. Length) Fixed Pressure Losses, when Elev 2 Total Flow ode 2 (Foot) (Q) Actual ID Length (psi) applicable, are added directly to (Pt) and shown as a Total Friction(Pt) (Foot) negative value. 166 18I11 5.6 19.60 1 (See 0'6 120 12.25 ' "Route I Notes) Sprinkler, 5-0 0.22 116 18'-5 Wit" 19.60 1.0490 0.125357 T(5'-O) 5I 0.69 116 ' 18-5 19.67 4 w 8'6 120 13.16 Flow (q) from Route 2 0.119267 115 18'-5 4 39.27 1.3800 8'-6 1.01 115 18-5 20.36 1/4 8-7% 120 14.17 Flow (q) from Route 3 0.258254 114 181-5 ad W" 59.63 1.3800 8-7% 2.23 114 18-5 21.93 1/4 1'-1Y2 120 16.40 Flow (q) from Route 5 0460947 113 18'-5 8156 13800 2 051 113 18'-5 21.36 ii' 7-7% 120 16. 91 Flow (q)from Route 4 708901 0.708901 -7% 112 18'-5 10292 13800 7I7/ 540 112 18'5 25.64 1% 6'-5 120 22.31 Flow (q) from Route 11 T(6'-O) 6'-O 1.069746 56 18'-5 128.56 1.3800 12'-5 13.28 56 18'-5 32.09 11/4 (See 1 '-8 120 35.59 Flow (q) from Route 16 6'-O 1.615440 0.72 7'8 12.39 55 16'-9 160.64 1.3800 PO(6'-O) 55 16'-9 3 12'-0 120 48.69 0.024555 53 16-9 W. 160.64 3.2600 12'-O 0.29 53 16'-9 151.86 3 12'-0 120 48.99 Flow (q) from Route 6 0.084092 51 16'-9 312.50 3.2600 12'-0 1.01 51 16'-9 106.36 3 (See 823% 120 50.00 Notes) Flow (q) from Route 10 3fE(6'-8!/2) 20'-2 0.144581 4.28 10 V-1 0% 418.86 3.2600 102'-5% 14.82 10 V-1 0% 3 (See 7'8 120 69.09 Notes) 48-4% 2.77 5 0-6 41886 32600 0144581 2f(-000),CV(216), 56'l 8.11 - BV(13'-5V4, 2fE(6'-8%) ,© M.E.P.CAD, Inc. jAutoSPRlNK® 12 v12.0.61.0 1 6/10/2017 11:09:05AM Page 4 J.J I VGAI • a... ..JU I MUO #I 11.11 IsI I emote Area Number: 1 Date: 6/10/2017 Pipe Information Mode 1 Elev I (Foot) K-Factor Flow added this step q Nominal ID Fittings & Devices (Foot) Length (Foot) C Factor ° Notes FittinglDevice (Equivalent Length) Pressure Losses, when are added directly to (Pt) and shown as a negative value. Fitting Pf Friction Loss Per Unit (psi) Elev(Pe) lode 2 Elev2 00) Total Flow (Q) Actual ID (Foot) Friction(Pt) 5 0'-6 4 (See Notes) 3'-6 140 79.96 E(17'-11) 17'-11 0.028873 1.52 4 -3'-O 418.86 4.2800 21'-5 0.62 4 4-0 4 (See Notes) 11'2 150 82.10 E(19'-2%) 19-2% 0.026910 3 -3'-O 418.86 4.2300 301 4% 0.82 3 4-0 4 (See Notes) 7'0 140 82.92 BFP(-12 00), E(17'-11) 17'-11 0028873 2 -3-0 41886 42800 24'-ll 1272 2 4-0 4 (See Notes) 27'0 150 95.64 Water Supply 0.026910 1 4-0 418.86 4.2300 27'-0 0.73 100.00 96.36 Hose Allowance At Source Total(Pt) Route I I 518.86 167 18'-11 5.6 19.67 1 (See Notes) 0'-6 120 12.34 'Route Sprinkler, E2'-0) 0.126225 117 18'-5 19.67 1.0490 2-6 032 117 18'-5 1% 8'-6 120 12.87 0.033198 116 18'-5 19.67 1.3800 8-6 0.28 13.16 Total(Pt) Route 2 165 18'-11 5.6 20.36 1 (See Notes) 0'-6 120 13.21 •••••Route3•'•'• Sprinkler, T(5'-O) 5-0 0.134454 0.22 115 18'-5 f*'a 20.36 1.0490 6-6 0.74 14.17 Total(Pt) Route 3 163 18'-11 5.6 21.36 1 (See Notes) 41 61/2 120 14.56 ••••'Route4'..'' Sprinkler, 21(5'-O) 10-0 0.147035 0.22 113 18'-5 21.36 1.0490 14'6% 2.14 16.91 Total(Pt) Route 4 164 18'-11 5.6 1 21.93 1 (See Notes) 0'-6 120 15.33 •• '•' Route 5. Sprinkler, T(5'-0) 5-0 0 154285 0.22 114 18'-5 21.93 1.0490 5' 6 085 ,© M.E.P.CAD, Inc. AutoSPRlNK® 12 v12.0.61.0 1 6/10/2017 11:09:05AM Page 5 lid I 'SQl I Ii.... Jid I U'..lO we 15.115.111 emote Area Number: I Pipe Information J Elev i I I Flow added Fittings & Length C Factor lode I (Foot) IK-Factor this step Nominal ID Devices (Foot) Fitting (q) Equiv. (Foot) Pf Friction Loss Per Unit Elev2 . Total Flow _______ Total lode 2 (Foot) (Q) Actual ID (psi) Length ..'• (Foot) (Foot) 159 109 18'-11 5.6 22.03 1 (See Notes) 0'6 120 5-0 0.155648 18'-5 11 nw, 22.03 1.0490 5' 6 109 108 18'-5 22.11 1% 8'-6 120 0 148077 18-5 44.15 1.3800 8'-6 108 107 181-5 22.87 1% 8-61/2 120 0.320522 18'-5 67.01 1.3800 8'-61/2 107 106 18'-5 24.59 1% 8'-9/2.3800 8'-9% 120 0571518 181-5 9161 1 106 54 18'-5 27.48 11/4 (See Notes) 6'5 120 6-0 0.928507 18'-5 119.09 1.3800 12'-5 54 53 18'-5 32.77 1Y4 (See Notes) 1'8 120 1.455774 169 151.86 1.3800 r- 160 110 18'-11 5.6 22.11 1 (See Notes) 0'6 120 2-0 0.156708 18-5 M. An 22.11 1.0490 2'-6 110 109 18'-5 11,4 8'-6 120 0.041215 18'-5 22.11 1.3800 8'-6 158 108 18'-11 5.6 22.87 1 (See Notes) 0'6 120 5-0 0.166755 18'-5 -r INS 22.87 XV.5'-6 1.0490 , © M.E.P.CAD, Inc. all AutoSPRINK® 12 v12.0.61.0 Date: 6/10/2017 Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as a negative value. Elev(Pe) Friction(Pf) 16.40 Total(Pt) Route 5 15.48 ••'••Route6••••• Sprinkler, T(5'-O) 0.22 0.86 16.55 Flow (q) from Route 7 1.26 17.81 Flow (q) from Route 8 2.74 20.55 Flow (q) from Route 9 5.02 25.58 Flow (q) from Route 14 T(6'-O) 11.53 37.11 Flow (q) from Route 17 PO(6'-O) 0.72 11.16 48.99 Total(Pt) Route 6 15.59 ••''•Route7'''•• Sprinkler, E(2'-O) 0.22 0.39 16.20 0.35 16.55 Total(Pt) Route 7 16.68 ''''Route8..... Sprinkler, T(5'-O) 0.22 0.92 17.81 Total(Pt) Route 8 6/10/2017 11:09:05AM Page 6 did IC1iIP.... '.JiJ IMid. _IILliidIU emote Area Number: 1 Pipe Information Elev I Flow added Fittings & Length C Factor Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) (q) Fitting Equiv. (Foot) Pf Friction Loss Per Unit Elev 2 Total Flow lode 2 (Foot)0 1 (Q) Actual ID Length (psi) Total (FooQ (Foot) 157 18-11 5.6 24.59 1 (See 0'6 120 Notes) 107 18'-5 24.59 1.0490. 0 190778 5'6 153 103 18'-11 5.6 25.60 1 (See Notes) 0'6 120 5-0 0.205455 18'-5 25.60 1.0490 5' 6 103 102 18'-5 25.69 1% 8'-6 120 0.195448 18'-5 51.29 1.3800 8'-6 102 101 18-5 26.55 8'-6Y2 120 0.422864 18'-5 77.84 1.3800 8'-66 101 52 18-5 28.52 1% (See Notes) 152/2 120 0753312 18'-5 10636 13800 21-2% 52 51 18'-5 11/4 (See Notes) V-8 120 6-0 0.753312 16'-9 106.36 1.3800 7'-8 162 18'-11 5.6 25.64 1 (See 0'6 120 ___ q1I 112 18'-5 25.64 1.0490 Notes) 5-0 5'6 0.205997 154 104 18'-11 5.6 25.69 1 (See Notes) 0'6 2'-0 18'-5 2569 10490 216 104 103 18'-5 iv4 8'6 18'-5 911111 25.69 1.3800:: 8'-6 Date: 6/10/2017 Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as a negative value. Elev(Pe) Friction(Pf) 19.29 '•'' Route S'*see Sprinkler, T(5'-O) 0.22 1.05 20.55 Total(Pt) Route 9 20.90 Route 10 Sprinkler, T(5'-O) 0.22 1.13 22.24 Flow (q) from Route 12 1.66 23.91 Flow (q) from Route 13 3.62 27.53 Flow (q) from Route 15 T(6'-O) 15.97 43.50 PO(6'-O) 0.72 5.78 50.00 Total(Pt) Route 10 20.96 Route 11 Sprinkler, T(5'-0) 0.22 1.13 22.31 Total(Pt) Route 11 21.05 ''Route 12.'... Sprinkler, E(2'-O) 0.22 0.52 21.78 0.46 22.24 Total(Pt) Route 12 120 0.206824 120 0.054396 , 0 M.E.P.CAD, Inc. AutoSPRINK® 12 v1 2.0.61.0 1 6/10/2017 11:09:05AM Page 7 Total(Pt) Notes FittinglDevice (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as a negative value. Elev(Pe) Friction(Pf) 22.48 ••'••Route 13''•'' Sprinkler, T(5'-O) 0.22 1.21 23.91 Total(Pt) Route 13 24.07 see •• Route 14'•••' Sprinkler, T(5'-O) 0.22 1.29 25.58 Total(Pt) Route 14 25.93 *sees Route 15'••'' Sprinkler, T(5'-O) 0.22 1.38 27.53 Total(Pt) Route 15 32.83 Route 16 Sprinkler, T(5'-O) 0.22 1.72 34.76 T(6'-O) 0.83 35.59 Total(Pt) Route 16 34.24 ••''Route17'''•• Sprinkler, T(5'-O) 0.22 1.78 36.25 T(6'-O) 0.86 37.11 Total(Pt) Route 17 156 18'-l1 5.6 27.48 1 (See 0'6 120 Notes) ____ __________ _______ 0.234188 106 18'-5 27.48 1.0490 151 18'-11 5.6 28.52 1 (See 0'6 120 Notes) 5'O 0.250833 101 18'-5 28.52 1.0490 5'6 Pipe Information Flow added Fittings & Length C Factor this step Nominal ID Devices (Foot) (q) Equiv. Fitting (Foot) Pf Friction Loss Per Unit Total Flow Total (Q) Actual ID Length (psi) (Foot) (Foot) 26.55 1 (See 0'6 120 Notes) 5-0 26.55 1.0490. . 0.219806 5'-6 Elev I Node 1 (Foot) K-Fad Mode 2 Elev2 (Foot) 152 18'-l1 5.6 .102 18'-5 161 18-11 5.6 111 18'-5 111 18'-5 56 18'-S 32.09 1 (See Notes) 0'6 120 5'-O 0.311987 32.09 1.0490 5'-6 1% (See Notes) 4-1 120 6'-O 0.082055 32.09 1.3800 10,-1 32.77 1 (See Notes) 06 51-0 32.77 1.0490 5'-6 1% (See Notes) 4'-1 6'-0 32.77 1.3800 io'-i 155 I 18'-l1 I 5.6 105 18'-5 19. 105 18-5 rM 54 18'-5 120 0.324428 120 0.085326 JLI IC4II. UIl uIUI.II emote Area Number: 1 Date: 6/10/2017 , 0 M.E.P.CAD, Inc. MI AutoSPRINK® 12 v12.0.61.0 1 6/10/2017 11:09:05AM Page 8 did I CII I l. %dd I %dl 11.11 idll emote Area Number: 1 Date: 6/10/2017 Actual Inside Diameter 4.87 = Factor Schedule 40 Steel Pipe Inside Diameter) Value Of C 100 130 140 150 Multiplying Factor 0.713 1.16 1.33 1.51 ALV Alarm Valve AngV Angle Valve b Bushing BalV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 900 cplg Coupling Cr Cross Run CV Check Valve DeIV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Eel 11W Elbow Ee2 22W Elbow f Flow Device fd Flex Drop FDC Fire Department Connectic fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow fig Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PlV Post Indicating Valve P0 Pipe Outlet PRV Pressure Reducing Valve PrV Pressure Relief Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve I Z Cap 0 M.E.P.CAD, Inc. J( AutoSPRINK® 12 v12.0.61.0 1 6/10/2017 11:09:05AM Page 9 Hydraulic Graph Job Name: C3 Kids Church N 1.85 Remote Area Number: I Date: 6/10/2017 Water Supply 35 - Summary Sheet _________ Node: I - - ____ _____ _______ ________ __________ ___________ Available Supply Static Pressure 124.00 20 - 518.86 - 117.00 @ 123.87 05 18.86 96.36 518.86 with Hose Allowance at Source go - 75- 60- S tem demand curve 30-i 15— 0_lf'jjj.LLUhmfumfh111111111 111111111 111111111 111111111 111111111 111111111 I I I I I I I 4- U900 1OUU 2700 .1bUU 400 4500 6300 Flow - gpm 7200 8100 9000 © M.E.P.CAD. Inc. AutoSPRINK® 12 02.0.61.0 6/10/2017 11:09:03AM Page 2 Hvaraullc uaicuiations for Project Name: C3 Kids Church Location: 2708 Gateway Rd., Carlsbad, CA 92008, Drawing Name: Fire Sprinkler Piping Plan.cad Calculation Date: 6/10/2017 Design Remote Area Number: Remote Area Location: Occupancy Classification: Density: Area of Application: Coverage per Sprinkler: Type of sprinklers calculated: No. of sprinklers calculated: 2 Classroom 1 & 2 Light Hazard 0.logpm/ft2 1500.00ft2 (Actual 990.03ft2) 196. 00ft2 Pendent 12 Type of System: Wet Volume of Dry or PreAction System: N/A In-rack Demand: N/A gpm at Node N/A Hose Streams: 100.00 at Node: I Type: Allowance at Source Total Water Required (including Hose Streams where applicable): From Water Supply at Node 1: 386.46 @83.87 Water Supply Information: Name of Contractor: Kingdom Builders Address: 2588 El Camino Real Suite# F337, Carlsbad, CA 92008 Phone Number: 760-855-6331 Name of designer: Freddy Alcaraz Authority Having JurisdictionCity of Carlsbad Fire Department Notes: M M.E.P.CAD, Inc. 11AutoSPRINKQD 12 02.0.61.0 2 6/10/201711:13:23AM Page 1 I itv _ Actual I . -- Minimum Flow Device (gpm) (gpm) K-Factor (K) Job Number: 17-872 Report Descriptiort Light Hazard (2) Pri a (psi) Sprinkler 251 30.00 19.60 5.6 28.70 Sprinkler 252 26.86 19.60 5.6 23.00 Sprinkler 253 25.47 19.60 5.6 20.68 Sprinkler 254 24.29 19.60 5.6 18.81 Sprinkler 255 24.33 19.60 5.6 18.87 Sprinkler 256 28.58 19.60 5.6 26.04 Sprinkler 257 23.38 19.60 5.6 17.43 Sprinkler 258 22.35 19.60 5.6 15.93 Sprinkler 259 21.04 19.60 5.6 14.12 Sprinkler 260 20.93 19.60 5.6 13.97 c Sprinkler 261 19.60 19.60 5.6 12.25 Sprinkler 262 19.64 19.60 5.6 12.31 c Most Demanding Sprinkler Data , © M.E.P.CAD, Inc. M AutoSPRINK® 12 v12.0.61.0 6/10/2017 11:13:25AM Page 3 JIJ U Nut II. I%I1. %JIiLii..lI emote Area Number: 2 Date: 6/10/2017 Pipe Information Elev I Flow added Fillings & Length C Factor Total(Pt) Notes Mode 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device (Equivalent (q) Equiv. Fitting (Foot) Pt Friction Elev(Pe) Length) Fixed Pressure Losses, when ode 2 Elev 2 al Flow Actual ID Length Tot _____ __ _ _________ Loss Per Unit applicable, are added directly Total (Foot) 1I1ti (Q) (Foot) (Foot) (psi) Friction(Pf) to (Pt) and shown as a negative value. 261 10,-Dy2 5.6 19.60 1 (See 37'-4% 120 12.25 .. • Route I .' Notes) Sprinkler, 12'-O -3.64 211 18'-5 19.60 1.0490 0.125357 E(2'-O), 2T(5'-O) 491 41/, 6.19 211 18'5 19.64 'P!4 14'-6 120 14.80 Flow (q) from Route 2 0.119104 210 18'-5 1 MW 39.24 1.3800 14'-6 1.73 210 18'.5 20.93 1¼ 1 6 2 1,4 120 16.53 Flow (q) from Route 3 0.262614 209 18'-5 60.17 1.3800 2-6% 0.67 209 18'5 21.04 1% 3'-8 120 17.20 Flow (q) from Route 4 0.457362 208 18'-5 81.21 1.3800 3'-8 1.69 208 18'5 22.35 5'-l% 120 18.88 Flow (q) from Route 5 0.717066 51 11/ 3.66 207 18'5 103.56 1.3800 207 18'-5 23.38 1¼ (See 6'5 120 22.55 _ Notes) Flow (q) from Route 6 T(6'-O) 6'-O 1.044960 60 18'-5 126.94 1.3800 12'-5 12.97 60 18'-5 28.58 1% (See 1'8 120 35.52 Notes) Flow (q) from Route 11 6'-O 0.72 59 16-9 155.52 1.3800 1.521322 PO(6'-O) 7'-8 11.66 59 16'-9 3 101-0 120 47.90 0.023124 101-0 57 16-9 155.52 3.2600 0.23 57 16'-9 130.94 3 (See 115'9% 120 48.14 Notes) Flow (q) from Route 7 20'-2 4.28 10 6'-1 0%286.46 3.2600 0.071589 3fE(6'-8%) 135'-1 1% 9.73 10 6'-10½ 3 (See 7'-8 120 62.15 Notes) 48'-4% 2.77 5 0'-6 286.46 3.2600 0.071589 2f(0.00), CV(216), 56'-1 4.01 BV(13'-5',4), 2fE(6'-8%) 5 0'-6 4 (See 3'6 140 68.93 Notes) 17'-11 1.52 4 -3'-O " 1.4. 111-1,271 1 286.46 4.2800 0.014297 E(17'-ll) 21'-5 0.31 , © M.E.P.CAD, Inc. Phl AutoSPRINK® 12 02.0.61.0 2 6/10/2017 11:13:26AM Page 4 JIJ I WI I I. I %II. I IUI UI I emote Area Number: 2 Pipe Information Elev . Flow added Fittings & Length C Factor Mode 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting q) Equiv. __ Pf Friction LOSS Per Unit Total Flow 'lode Actual ID (Foot) (Foot) 4 4-0 4 (See 11 '-2 150 Notes) 19-2'/2 0.013325 30'-41/2 3 -3'-O 286.46. 4.2300 3 4-0 4 (See 7'O 140 Notes) 17111 0.014297 24'-11 2 -3'-O 286.46 4.2800 2 3'Q 4 (See 27'0 150 Notes) 0.013325 27'-O I 4-0 286.46 4.2300 100.00 I 386.46 262 10'-O% 5.6 19.64 1 (See 376 120 Notes) 91-0 0.125881 46-6 212 18'-5 19.64 1.0490 212 18'-5 iv4 86 120 0.033107 8'-6 211 18-5 19.64 1.3800 260 210 101-0 5.6 ______ 20.93 __________ 1 ________ (See Notes) 3610 120 0.141515 18'-5 20.93 1.0490 43'..10 259 209 101-0Y2 5.6 21.04 1 (See Notes) 35'0 120 12-0 0.142956 18'-5 21.04 1.0490 47'O 258 208 101-0 5.6 22.35 1 (See Notes) 343% 120 7-0 0.159790 18'-5 22.35 1.0490 411 31/ Date: 6/10/2017 Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as a negative value. Elev(Pe) Friction(Pf) 70.75 E(19'-2Y2) 0.40 71.16 BFP(-12.00), E(17'-11) 12.36 83.51 Water Supply 0.36 83.87 Hose Allowance At Source Total(Pt) Route I 12.31 ••••• Route 2••••• Sprinkler, 2E(2'-O), T(5'-O) -3.64 5.86 14.52 0.28 14.80 Total(Pt) Route 2 13.97 •••••Route3'•''' Sprinkler, E(2'-O), T(5'-O) -3.64 6.20 16.53 Total(Pt) Route 3 14.12 ••'••Route4•••.' Sprinkler, E(2'-0), 2T(5'-0) -3.64 6.72 17.20 Total(Pt) Route 4 15.93 •• '•'Route 5•.... Sprinkler, E(2'-O), T(5'-O) -3.64 6.60 18.88 Total(Pt) Route 5 , © M.E.P.CAD, Inc. plj AutoSPRINK® 12 v1 2.0.61.0 2 6/10/2017 11:13:26AM Page 5 IJ I Vr41 11%.. I %IUO JI IUU I emote Area Number: 2 Pipe _Information Elev 1 I I Flow added Fittings & Length C Factor Node I (Foot) IK-Factori 1 this step I Nominal ID Devices (Foot) Fitting (q) Equiv. (Foot) Pf Friction Loss Per Unit Elev 2 Total Flow ______ Total Mode 2 (Foot) (Q) Actual ID Length (psi) (Foot) (Foot) 257 10'-O% 5.6 23.38 1 (See 385 120 Notes) 12'-O 207 18'-5 I-on 23.38 1.0490 0.173695 50'5 254 204 10'-O% 5.6 24.29 1 (See Notes) 366 120 0.186423 18'-5 24.29 1.0490 47-6 204 203 18'-5 24.33 1% 17-0/2 120 0.177013 18'-5 48.62 1.3800 17'-0Y2 203 202 18'-5 25.47 1 V 8'-9Y2 120 0.385852 18'-5 74.08 1.3800 8'-9Y2 202 58 18'-5 26.86 1% (See Notes) 6-5 120 0.683866 18'-5 100.94 1.3800 58 57 18'-5 30.00 1% (See Notes) 1'8 120 6-0 1.106744 16'-9 JWWI 130.94 1.3800 78 255 205 10'-0% 5.6 24.33 1 (See Notes) 3591/2 120 0.186967 18'-5 24.33 1.0490 449 1/ 205 204 18'-5 1% 8'-6 120 0.049174 18'-5 sat 24.33 1.3800 8-6 253 10'-0% 5.6 25.47 1 (See 372 120 Notes) 12'-O 203 18'-5 25.47 1.0490 49-2 0.203467 Date: 6/10/2017 Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as a negative value. Elev(Pe) Friction(Pf) 17.43 ••.'' Route 6•''•' Sprinkler, E(2'-0), 2T(5'-O) -3.64 8.76 22.55 Total(Pt) Route 6 18.81 •••'• Route 7'•'•• Sprinkler, E(2'-O), 2T(5'-O) -3.64 8.85 24.03 Flow (q) from Route 8 3.02 27.05 Flow (q) from Route 9 3.39 30.44 Flow (q) from Route 10 T(6'-O) 8.49 38.93 Flow (q) from Route 12 PO(6'-O) 0.72 8.49 48.14 Total(Pt) Route 7 18.87 ' Route 8 Sprinkler, 2E(2'-O), T(5'-O) -3.64 8.38 23.61 0.42 24.03 Total(Pt) Route 8 20.68 '••• Route 9'•••• Sprinkler, E(2'-0), 2T(5'-O) -3.64 10.01 27.05 Total(Pt) Route 9 I k, 0 M.E.P.CAD, Inc. JAutoSPRlNK® 12 v12.0.61.0 2 6/10/2017 11:13:26AM Page 6 Elev I odeI (Foot) Elev 2 1ode2 (Foot) 252 I0'-O% 202 18'-5. 256 206 10'-0Y2 5.6 28.58 1 (See Notes) 37'.51/2 120 12-0 0.251798 18'-5 28.58 1.0490 206 60 18'-5 1% (See Notes) 4'-1 120 6'-0 0.066224 1815 28.58 1.3800 10,-1 251 201 I0'-0% 5.6 30.00 1 (See Notes) 358 120 12'-O 0.275552 18'-5 30.00 1.0490 47-8 201 58 18'-5 1v4 (See Notes) 4'1 120 6-0 0.072472 18'-5 30.00 1.3800 10,-1 Total(Pt) Notes FittinglDevice (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as a negative value. Elev(Pe) Friction(Pt) 23.00 '••' Route lO•''•• Sprinkler, E(2'-O), 2T(5'-O) -3.64 11.08 30.44 Total(Pt) Route 10 26.04 Route 11 Sprinkler, E(2'-O), 2T(5'-O) -3.64 12.45 34.85 T(6'-O) 0.67 35.52 Total(Pt) Route II 28.70 '•'• Route 12•••'' Sprinkler, E(2'-O), 2T(5'-O) -3.64 13.13 38.20 T'6' 0 0.73 38.93 Total(Pt) Route 12 Pipe Information Flow added Fittings & Length C Factor this step Nominal ID Devices (Foot) (q) Equiv. Fitting (Foot) Pf Friction Loss Per Unit Total Flow Total (Q) Actual ID Length (psi) (Foot) (Foot) 26.86 1 (See 37-4 120 Notes) 12'-O 26.86 1.0490 0.224533 14 49 5.6 did U ICAS U 1¼... %#J I ¼Iid. 'SI IUI UI I emote Area Number: 2 Date: 6/10/2017 ,© M.E.P.CAD, Inc. P..jAutoSPRlNK® 12 v12.0.61.0 2 6/10/2017 11:13:26AM Page 7 JIJ I 1CA1 I I. .ISI I JI UUI UI I emote Area Number: 2 Date: 6/10/2017 VálIj ( Actual Inside Diameter 4.87 = Schedule 40 Steel Pipe Inside Diameter) Factor Value Of C 100 130 140 150 Multiplying Factor 0.713 1.16 1.33 1.51 ALV Alarm Valve AngV Angle Valve b Bushing BaIV Ball Valve BFP Backfiow Preventer BV Butterfly Valve C Cross Flow Turn 90' cplg Coupling Cr Cross Run CV Check Valve DelV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 450 Elbow Eel 111/0 Elbow Ee2 22W Elbow f Flow Device fd Flex Drop FDC Fire Department Connectic fE 900 FireLock(TM) Elbow fEE 450 FireLock(TM) Elbow fig Flange• FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve P0 Pipe Outlet PRV Pressure Reducing Valve PrV Pressure Relief Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Turn 900 Tr Tee Run I U Union WirF Wirsbo WMV Water Meter Valve I Z Cap ,© M.E.P.CAD, Inc. JAUtOSPRINK® 12 v12.0.61.0 2 6/10/2017 11:13:26AM Page 8 Hydraulic Graph Job Name: C3 Kids Church N 1°5 Remote Area Number: 2 Date: 6/10/2017 - Water Supply 35 T SummarNody Sheet Available Supply Static Pressure 124.00 1 20T 386.46 @ 123.93 500.00 @117.00 - - 90H 286.46 83.87 386.46 with Hose Allowance at Source 75- 60- System demand curve_______ 30— 0_..Il.1.l.I.I.LI.Lf1Illltlit 111111111 111111111 I 111111111 lilt 11111 I III I ii I II I I I I I I I I U900 1bUU 2700 Jbuu 5400 4500 6300 Flow - gpm 7200 8100 9000 M.E.P.CAD, Inc. AutoSPRINK® 12 v12.0.61.0 6/10/2017 11:13:24AM Page 2 Flexible Sprinkler Drops Unbraided Flexible Sprinkler Connection Data Sheet EASYFLEX Flexible Sprinkler Drops are designed to significantly reduce labor and installation costs. By eliminating the need for pipe cutting and midline connections, you save valuable time and money. Easyflex flexible sprinkler connections offer braided and unbraidecl flexible hoses in 2',3',4',5', and 6' with top loading or front loading brackets for variety of ceiling and wall applications: T-Bars, metal studs, hat channels, wood beams, concrete sidewalls, and more. The system is qualified to be installed at commercial, hotel, retail, restaurants, cultural, entertainment, educational, government, healthcare, and religious buildings. EASYFLEX Flexible Sprinkler Drops Appliance Standards National Fire Protection Association (NFPA): NFPA 13: Standard for the Installation of Sprinkler Systems NFPA 131): Standard for the Installation of Sprinkler Systems in One and Two-Family Dwellings and Manufactured Homes NFPA 13R : Standard for Installation of Sprinkler Systems in residential Occupancies up to and including tour stories in height NFPA 13 Section 9.2-.1.3.3.3: No hangers are requird for flexible connections as long as the length does not exceed 61t. American Society for Testing and Methods (ASTM): ASTM C635 : Standard specifications for the manufacture, performance, and testing of metal suspension systems for acoustical tile and lay-in panel ceilings ASTM C636: Standard practice for ins1allaton of metal ceiling suspension systems for acoustical tile and lay-in panels Underwriter's Laboratories, Inc. UL/ULc, cUL us 2443: Standard for flexible sprinkler hose with fittings for fire protection service International Building Code(IBC)Section 1621 / American Society of-Civil Engineers (ASCE) 79.6.2.6.2 &9.6.2.6.2.2: Flexible Sprinkler Connections are an alternative solution to install without seismic escutcheons Job Name: Engineer / Architect: Job Location: Wholesaler: Submittal Date: Contractor: rv:FD.201601 WEST OFFICE Toll Free (888) 577-8999 9 info@easyflexusa.com EAST OFFICE Toll Free (855) 388-2600 9 info@easyflexeast.com ECHNICAL SPECIFICATIONS EJNRRAIDEfl FLEXIRLIE HflE SPECIFICATIONS Lengths Available 280,40,4860 and 67 Hose Stainless Steel 304 Outlet - 112" or 3/4" Nut & Nipple Zinc-Plated Steel Hose Type Unbraided sealing Gasket EPDM/ NYLON Isolation Ring Max. Ambient 225°F Temperature Rating Max. Working 175 Si p g Pressure Rating No hangers and seismic escutcheons required * Required torque to assemble reducer and nipple with the flexible hose :50 ft-lb 6" (ULIULC) Minimum Bend-Radius * DO NOT bend within 2.52 inches from connection nuts Inlet 1"NPT Connection Outlet 1/2" or 3/4"NPT I&I FRICTION LOSS DATA LISTED EFU Series Unbralded Hose EX6276 lBS-PA Bracket Systems Length On.) Outlet Connection I K-Factor Max. Number of 90° Bends Equivalent Length of un. Schedule 40 Pipe, ft. 1/2° 5.6 1 18 28° 3/4" 8.0 - 1 22 1/2° 5.6 : 2 32 40" 3/40 8.0 2 39 48" 1/2" 5.6 I 2 38 - -- - 3/4° 8.0 2 44 1/2° 5.6 3 55 60" 3/4" 8.0 3 61 1/2" 67" 5.6 3 63 3/4' 8.0 - 3 83 UL: 6" minimum bend radius, where C=120 'D.216O1 WEST OFFICE Toll Free (888) 577-8999 • in1oeasyfiexusa.com EAST OFFICE Toil Free (855) 388-2600 • info@easyflexeast.com 175 PSI 140°F 350 PSI ZURN Mo.el 475DA14751 w WILKINS Reduced Pressure Detector Assembly Application Designed for installation on water lines in fire protection systems ( I to protect against both backsiphonage and backpressure 4 Gat of contaminated water into the potable water supply. The Model 475DA/475DAV shall provide protection where a po- tential health hazard exists. Incorporates metered by-pass to detect leaks and unauthorized water use. Standards Compliance ASSE® Listed 1047 (4" thru 8") AWWA Compliant C550 UL® Classified (4" thru 10") C-UL® Classified (4" thru 10") FM® Approved (4" thru 8") NYC MEA 170-02-M VOL 2 (4-8") Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California (4" thru 8") NSF® Listed-Standard 61, Annex G* *(025% MAX. WEIGHTED AVERAGE LEAD CONTENT) Materials Main valve body Ductile Iron ASTM A 536 Grade 4 Access covers Ductile Iron ASTM A 536 Grade 4 Coatings FDA Approved fusion epoxy finish Fasteners Stainless Steel, 300 Series Elastomers EPDM (FDA approved) Buna Nitrile (FDA approved) Polymers NORYLTM, NSF Listed Springs Stainless steel, 300 series Features Sizes: 4", 6", 8", 10" Maximum working water pressure Maximum working water temperature Hydrostatic test pressure End connections (Grooved for steel pipe) AWWA C606 (Flanged) ANSI B16.1 Class 125 Relief Valve discharge port: 2 1/2" - 6" - 2.75 sq. in. 8" - 10" - 3.69 sq. in. w I_!!_ANsl MG MODEL 475DAV MODEL 475DA Options (Suffixes can be combined) El - with OS & V gate valves (standard) E] L - less shut-off valves (grooved body connections) D LM - less water meter - with remote reading meter LI - with gpm meter (standard) R - with cu ft/min meter E] V - vertical flow up configuration LI G - with groove end gate valves E] FG - with flanged inlet gate connection and grooved outlet gate connection 0 MS - with integral relief valve monitor switch BGVIC - with grooved end butterfly valves with integral supervisory switches LI P1 - with post indicator gate valve Accessories O Air gap (see spec sheet BF-AG) O Repair kit (rubber only) O Thermal expansion tank (Model XI) O Valve setter (Model FLS or O MJS0rMJFS) O Gate valve tamper switch (OSY-40) QT-SET Quick Test Fitting Set T I Dimensions & Weights (do not include pkg.) DIMENSIONS (approximate) WEIGHT MODEL i, B B B C C C LESS OS&Y WITH 475DAV A WITH GATE WITH BFLY LESS GATE OS&Y OS&Y WITH BFLY D GATE GATE BFLY SIZE VALVES VALVES VALVES OPEN CLOSED VALVES VALVES VALVES in. mm mm in. I mm in. mm in. I mm in. mm in. mm in. min Uskgths thskg 4" 475DA 185/16 465 30 1 762 273/4 705 21 533 22 3/4 578 18 1/4 464 91/2 241 8 203 113 151.3 303 137.4 151 68.5 475DAV _4" 187/8 479 361/2 927 32 813 181/2 470 223/4 578 181/4 464 91/2 241 51.3 303 137.4 151 68.5 6" 475DA 1811/16 475 351/2 902 321/8. 816 25 635 301/8 765 233/4 603 101/2 267 84.9 487 221 243 110.2 6"475DAv 21 533 42 1067 351/4 895 21 533 301/8 765 23 3/4 603 10 1/2 267 7 84.9 487 221 243 110.2 8" 475DA 29 737 46 1168 429/16 1081 347116 875 373/4 959 29 1/4 743 13 330 t330 1 191.1 897 406.8 543 246.3 8" 475DAV 305/16 770 531/2 1359 469/16 1183 305/16 770 373/4 959 291/4 743 13 330 1 191.1 897 406.8 543 246.3 10"475DA 737 471/2 1207 447/16 1129 347/16 875 453/4 1162 353/8 899 135/16 338 9 199.3 1113 'iO4. 10' 475DAV 305/16 770 561/2 1435 505/16 1278 305/16 770 453/4 1162 353/8 899 135/16 338 9 l99 1113 "10&E' 625 2835 Zurn Industries, LLC I Wilkins 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 In Canada I Zurn Industries Limited 3544 Nashua Drive, Mississauga, Ontario L4V 1L2 Ph. 905-405-8272, Fax 905-405-1292 Rev. C Date: 12/13 Document No. BF-4750A&V Patent No. 5,913,331 Product No. Model 475DA & 475DAV www.zurn.com I Page 1 of 2 100.9 _______ 138 0. (150mm):- 103 69 'ii Cl) 34U) w 0 ° 1600 189.3 0' Flow Characteristics Rated Flow (established by approval agencies) (UL curve) 0.0 O 20 U) - a. - 15 U) 0 - -j W 10 U) 5 U) W - a.0 MODEL 475DA & 475DAV 4" & 6" (STANDARD & METRIC) FLOW RATES (us) 25.2 50.5 75.7 0 400 800 1200 FLOW RATES (GPM) MODEL 475DA & 475DAV 8" & 10" (STANDARD & METRIC) 0.0 63.1 FLOW RATES (us) 126.2 20__ 200mm ______ - 0 10 D U) 5 0.0 0 1000 2000 3000 FLOW RATES (GPM) Typical Installation Local codes shall govern installation requirements. To be installed in accordance with the manufacturers' instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. Capacity thru Schedule 40 Pipe (GPM) Pipe size 5 ft/sec 7.5 ft/sec 10 ft/sec 15 ft/sec 2 1/2" 75 112 149 224 115 173 230 346 198 298 397 595 6" 450 675 900 1351 8" 780 1169 1559 2339 10" 1229 1843 2458 3687 MODEL SIZE in. I mm DIMENSIONS (approximate) Al SETTER END TO END FLS in. I mm Al SETTER END TO END MJS in. I mm 4 1001315/161795 295/16 745 6 150 34 3/4 884 32 3/4 832 8 200 47 J 1194 445/8 1133 10 250 51 1295 47 1194 WL VERTICAL INSTALLATION OUTDOOR INSTALLATION Specifications The Reduced Pressure Detector Assembly shall be ASSE® Listed 1047, and supplied with full port OS & V gate valves. The main body and access covers shall be epoxy coated ductile iron (ASTM A 536 Grade 4), the seat ring and check valve shall be NORYLTM, the stem shall be stainless steel (ASTM A 276) and the seat disc elastomers shall be EPDM. The first and second checks shall be accessible for maintenance without removing the relief valve or the entire device from the line. If installed indoors, the installation shall be supplied with an air gap adapter. The Reduced Pressure Detector Assembly shall be a ZURN WILKINS Model 475DA or 475DAV. Zurn Industries, LLC I Wilkins 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-236-5766 In Canada I Zurn Industries Limited 3544 Nashua Drive, Mississauga, Ontario L4V 1 L2 Ph. 905-405-8272, Fax 905-405-1292 www.zurn.com Page 2 of 2 CARLSBAD FIRE DEPARTMENT Fire Prevention Division 1635 Faraday Avenue - Carlsbad, CA 92008 760.602.4665 WATER AVAILABILITY FORM SECTION A: TO BE COMPLETED BY CUSTOMER PROJECT NAME: C-3 Childrens' Church SR#: (Assigned upon plan submittal) PROJECT ADDRESS: 2708 Gateway Road CITY: Carlsbad PHONE: ( 619) 266.6030 (Industrial Fire Sprinkler Company) FAX NUMBER: (619) 266.6035 Largest Building (ft.2):________________________________ Sprinkled? Construction Type:__________________ SECTION B: TO BE COMPLETED BY CONSULTANT. CUSTOMER TO PROVIDE RESULTS TO CFD. Water Purveyor: City of Carlsbad Location of test (reference map required): north of Gateway Road east of El Fuerte TEST INFORMATION IS VALID FOR 6 MONTHS FROM DATE PERFORMED Flow Test Results Static pressure: 124 PSI Hydrant Number (if applicable):H62100 Elevation of test 413 Feet 7. Date/Time of Test1 Pitot Tube Reading - PSI Corresponding Flow - GPM Total Flow: 4.500 GPM Residual Pressure 117 PSI Atpeak demand, this water system is capable of providing a fire flow discharge @ 20 psi in excess of 8,000 GPM. However, this exceeds the District's 10 fps maximum velocity criteria. Therefore, the maximum allowable fire flow is 4,500 gpm. 1Test to be performed as close as possible to the time the most conservative flows and pressures are expected. Note: If the water availability information was obtained in a manner other than a flow test (i.e. computer modeling), fill out the information above as applicable and check here: x Name: JenniferR.Mael,P.E. Eng. Lic. No. (if applicable): C69606 Signature:__________________________________________ /_ 1/ Title/Org: PLo_ctManager Date: 05/17/2017 4 QUICK RESPONSE UPRIGHT CONVENTIONAL QUICK RESPONSE HORIZONTAL LPC/CE SIDEWALL HORIZONTAL SIDEWALL QUICK rESPONSE A U TOMA TI C SPRINKLERS GL SERIES UPRIGHT • PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) GLOMOE BE FIRE SPRINKLER CORPORATION DESCRIPTION AND OPERATION The Globe Quick Response GL Series Sprinklers are a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. While the Quick Response Sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard spray sprinklers are specified when allowed by the applicable stan- dards. It offers the additional feature of greatly increased safe- ty to life and is available in various styles, orifices, temperature ratings and finishes to meet many varying design requirements. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction. The heart of Globe's GL Series sprinkler proven actuat- ing assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is ab- sorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distrib- uted in an approved pattern depending upon the deflector style used. TECHNICAL DATA See reverse side for Approvals and Specifications. Temperature Ratings - 135°F (57°C), 155°F (68°C), 175°F (79°C), 200°F (93°C), 286°F (141°C) Water Working Pressure Rating - 175 psi (12 Bars) Factory tested hydrostatically to 500 psi (34 Bars) Maximum low temperature glass bulb rating is -67°F (-55°C) Frame - bronze • Deflector - brass • Screw - brass Lodgement Wire - stainless steel • Bulb seat - copper Spring - nickel alloy • Seal - teflon o Bulb - glass with alcohol based solution, 3mm size oSPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING CLASSIFICATION AVAILABLE SPRINKLER BULB COLOR N.F.P.A. MAXIMUM TEMPERATURES CEILING TEMPERATURE ORDINARY 5°F ® 0 ORANGE/RED INTERMEDIATE YELLOW/GREEN 6 HIGH 286 .1 BLUE 0 G APR 2017 GFS-1 00a (Formerly A-20) QUICK RESPONSE A U TOMA TI C SPRINKLERS GL SERIES UPRIGHT PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) SPECIFICATIONS NOMINAL "K" FACTOR THREAD SIZE LENGTH' FINISHES 2.8 (40 metric) 1/2"NPT (15mm) 2 1/4° (5.7cm) 4.2 (60 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) Factory Bronze 5.6 (80 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) Chrome white :ster2 8.0 (115 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) Black Polyester23 8.0 (115 metric) 3/4"NPT (20mm) 1 2 7/16" (6.2cm) NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 'HORIZONTAL SIDEWALL IS 2 9/16°. °FINISHES AVAILABLE ON SPECIAL ORDER. 'AVAILABLE AS cULus LISTED COROSION RESISTANT WHEN SPECIFIED ON ORDER. APPROVALS TEMPERATURE STYLE SIN MODEL K FACTOR HAZARD' cULus FM LPC CE NYC - DOB MEA 101-92-E 135°F 155°F 175°F 200°F 286°F (57°C) (68°C) (79°C) (93°C) (141°C) GL2815 2.8 LH X X X X X X -- - -- X GL4215 4.2 LH X X X X X X -- - - X UPRIGHT GL5615 5.6 LH/OH X X X X X X X X X X GL8115 8.0* LH/OH X X X X X X - - - X GL8118 8.0 LH/OH X X X X X X X X X X GL2801 2.8 LH X X X X X X -- -- - X GL4201 4.2 LH X X. X X X X -- - - X PENDENT GL5601 5.6 LH/OH X X X X X X X X X X GL8101 8.0* LH/OH X X X X X X --- - --- X GL8106 8.0 LH/OH X X X X X X X X X X VERTICAL GL5632 5.6 LH X X X X X X X - --- - SIDEWALLt GL8133 8.0 LH X X X X X X - - -- - GL2826 2.8 LH X X X X X X -- - X HORIZONTAL GL4226 4.2 LH X X X X X X -- - - X SIDEWALL GL5626 5.6 LH/OH X X X X X X X --- x GL5627u 5.6 LH/OH X X X X X --- -- X X GL8127 8.0 LH/OH X X X X X X -- -- -- - CONVENTIONAL GL5624 5.6 LH/OH X X X X X --- --- X X - (OLD STYLE) GL8125 8.0 LH/OH X X X X X --- -- X X - 0rrsui'1rLrw OnALL Dt LIMI I tU AS PER THE REQUiREMEN TJS OF Nh'Ali AND ANY UTI1bK RELATED DOCUMENTS. §HORIZONTAL SIDEWALL cULus LISTED FOR DEFLECTOR 4" TO 12" BELOW THE CEILING, FM APPROVED 4" TO 6" BELOW THE CEILING. INSTALL IN ACCORDANCE TO B55306 AND ANY OTHER RELATED DOCUMENTS. fPENDENT VERTICAL SIDEWALL cULus LISTED FOR 6' MIN. SPACING. tUPRIGHT VERTICAL SIDEWALL cULus LISTED FOR 9' MIN. SPACING. OH: ORDINARY HAZARD LH: LIGHT HAZARD *1/2"NPT ORDERING INFORMATION SPECIFY Quantity • Model Number Style . Orifice Thread Size • Temperature • Finishes desired Quantity - Wrenches - PIN 325390 (1/2"); P/N 312366 (L.O.) GL68 E FIRE SPRINKLER CORPORATION APR 2017 GLOBE® PRODUCT WARRANTY Globe agrees to repair or replace any of its own manufactured products found to be defective in material or workmanship for a period of one year from date of shipment For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). GFS-1 00a (Formerly A-20) PRINTED U.S.A. 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 FAX 989-846-9231 1-800-248-0278 www.globesprinkler.com t 1318 .250 j(00 2.0312 ./ SIZE - ROD: 3/8" SIZE - SYSTEM PIPE: 4" max. MATERIAL - Carbon Steel or S.S. (Type 304). FINISH - Mil. Galvanized. LISTING/APPROVAL - Special Note: The purlin lip is not capable of supporting NFPA 13 fire sprinkler pipe at l(wt.) +250 lbs mm. When purlin manufacturers specify 200 lbs. max. P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 551 REVOLVER Tu 203 - EX 2551 PATENT - No. 6,568,642 FUNCTION - Attachment component of an AFCON hanger. To support horizontal piping. INSTALLATION - Per NFPA 13 and these instructions. Install on vertical mounting surface. ASSEMBLY/ATTACHMENT - See drawing. Center mounting hole accepts 3/8" and 1/2" fasteners. SPECIAL c®u. FASTENERS PER NFPA 13-See table. FEATURES * Universal fastener array for enhanced mounting. * Hangs plumb from one fastener. * Radius -Tapped Rod Bore: Improves thread engagement and eliminates structural deficiencies associated with rod inserts. * No backing nuts required. ORDERING - Part # and finish. I tWu STEEL PIPE MOUNTING FASTENERS I Steel - #14 SMS or #14 Tek Steel - #10 SMS or #905 Wood Q ty. Pipe Size Mm. Qty. Pipe Mm. Qty. Pipe Thickness Size Thickness Size 1/4 x I V2 LS 1 2 14 GA. 1 3 18 GA. 1 2 Y2 24 24 2 3 #14x I Y2 SMS 1 2 16 GA. 1 2 Y2 3 4 2 4 2 4 20 GA. 2 3 #16x2DS 2 2 18 GA. 1 2¼ 4 4 3 4 2 3 22 GA. 3 3 Wood - Thru 5/8" Gyp 3 4 1/4x2 LB I 2 20 GA. 2 *1 2 4 * @ B ONLY 2 3 SMS - Sheet Metal Screw DS Drive Screw #l4x2SMS 1 2 3 4 LS Lag Screw 2 4 22 GA. 3 2 /2 Gyp- Gypsum Board Telc-Tek Screw Fastener Locations 5 1@ BorE 30 A-C-B ® 2@ B-B 30 B-D-F - F ® 2@ A-C 40 A-C-D 11115 F11~7 5~ 7 Features & Benefits Solid, one-piece, cold formed and machined anchor Entire system requires only one driver self-drilling (except for self-tapping threads point HangerMate LG for steel applications anchors) Heads precision drilled and gimlet point tapped to twin-lead threads with slot accept 3/8-16 for wood applications or 1/4-20 threaded components -gimlet point EZE270 twin-lead threads adapter allows for concrete applications installation of 1/2-13 threaded rod self-drilling components special threads point LG style allows MP style for steel, wood installation of or concrete applications threaded rod systems into light-gage metals MP style can be used in metal, wood or concrete, reducing the number of parts that need to be stocked Different thread and point styles available to meet the requirements of specific application materials Special hex nuts supplied as required Many styles UL listed and/or FM approved (see table inside) Ease assembly of HVAC, fire sprinkler, refrigeration, piping, and electrical systems for ceiling- or wall-mounted applications HANGEAALAe. Threaded Rod Anchoring System HangerMate® anchors were designed to speed installation of fire sprinkler, HVAC, refrigeration, general piping, and electrical systems. They can also be used to install strut channels, cable trays, suspended ceiling grids, bridle rings and eye-rods. HangerMate anchors can replace beam clamps, powder-actuated stud pins, eye sockets, or ceiling flanges, and eliminate labor-intensive operations such as pre-punching or drilling of steel components. Power of One The entire system has been re-engineered so only one driver is needed for all anchor sizes (except HangerMate LG anchors), regardless of the substrate material. Preparing concrete applications is accomplished with a standard 1/4" drill bit. Head Styles Two head styles are available: HangerMate vertical-mount anchors feature a tapped head end-drilled to permit in-line mounting of head threaded rod systems HangerMate side-mount anchors feature a cross-drilled and tapped head to permit side-mounting of threaded rod systems cross-drilled head Both head styles feature a wide array of thread and point styles for use in steel, concrete, masonry or wood applications, including the MP style that can be used in all three materials. Many styles are Factory Mutual (FM) approved or Underwriters Lab (UL) listed (see following pages). Find out just how versatile and beneficial the HangerMate anchoring system can be. pi Elco Construction Products e 1301 Kerr Drive ' Decorah, IA 52101 1.800.435.7213 Fax: 563.387.3540 www.elcoconstruction.com HangerMate® TI.. ded Rod Anchoring System Steel Applications* Vertical Mount - End-Drilled Head Rod I 1/4-20 Steel ' .060 -250 .250 ' EZG 160 1/4-20X1 #3 point UL Pipe N/A UL Steel ' N/A FIVI Pipe N/A FIVI Steel N/A 3/8-16 .060 -.125 EZG450 1/4-20X1 #2 point 4° 0.125 3/8-16 .060 -.250 EZG470 114-20X1 #3 point 411 0.125° 4° 12 ga. 3/8-16 .060 -.250 EZG471 1/4-20X1#3 point w/nuts 4° 0.060° 4° 16 ga. 3/8-16 .060 -.250 EZG490 1/4-20X1-1/2 #3 point 4° 0.125° 4° 12 ga. 3/8-16 .060 -.250 EZG491 1/4-20X1-1/2 #3 point w/nuts 4° 0.060 4' 16 ga. 3/8-16 .060 -.250 EZG530 1f4-20X2 #3 point 4° 0.125° 3/8-16 .060 -250 .250 EZG540 1/4-20X3 #3 point 3/8-16 .187 -500 .500 EZG510 1/4-20X1-1/2 #5 point 4' 0.125 4' 0.125° 3/8-16 .060 -.500 EZG511 1/4-20X1-112 #5 point w/nuts 4- 0.060 4" 16 ga. t 1/4-20 26 ga. -.187 EZG610 1/4-20 collapsing insert N/A N/A N/A N/A 3/8-16 26 ga. -.187° EZG580 1/4-20X1; use with EZG610 2.5° 22 ga. 4" 12 ga. 3/8-16 26 ga. -.187° EZG590 1/4-20X1; use with EZG610 3.5° 18 ga. 4" 12 ga. 3/8-16 26 ga. -.187° EZG600 1/4-20X1; use with EZG610 4° 16 ga. 4' 12 ga. Horizontal Mount - Cross-Drilled Head 1/4-20 ' .060 -250 .250 EZHI55 ' 1/4-20X1 #3 point ' N/A ' N/A N/A N/A 3/8-16 .060 -125 .125 EZH455 114-20X1 #2 point 3/8-16 .060 -.250 EZH475 1/4-20X1#3 point 3/8-16 .060 -250 .250 EZH476 1/4-20X1 #3 point w/nuts 4° 0.060° 4" 16 ga. 3/8-16 .060 -.250 EZH495 114-20X1-112 #3 point 3/8-16 .060 -250 .250 EZH496 1J4-20X1-1/2 #3 point w/nuts 4' 0.060° 4° 16 ga. 3/8-16 .187 -.500 EZH515 1J4-20X1-112 #5 point 3/8-16 .060 -.500 EZH516 1/4-20X1-1J2 #5 point w/nuts 4" 0.060° 4° 16 ga. 3/8-16 .060 -.250 EZH535 1/4-20X2 #3 point NOTE: It is the responsibility of the installer to determine the application-specific details under which a code approval or listing was granted. Contact Elco Construction Products for more information. tCollapsing insert EZG610 can be used alone to install 1/4-20 threaded components or with EZG580, EZG590 or EZG600 hangers to install 3/8-16 threaded components. *Installation in Steel or Wood Applications: Use EZE215 drive socket (see next page). Hex drive will automatically disengage when anchor is seated. HangerMate . . ireaded Rod Anchoring System Wood Applications* Vertical Mount - End-Drilled Head 1/4-20 EZG315 5/16X2-1/4 NA NA 3/8-16 EZG650 5/16X2-1/4 4" 4° 3/8-16 EZG670 5/16X3 4" 4' Horizontal Mount - Cross-Drilled Head ;r Size Elco Cat. No. '11F1l ,. UL Pipe Size FM Pipe Size 1/4-20 EZH320 5/16X2-1/4 NA NA 3/8-16 EZH665 5/16X2-114 3-1/2" Concrete Applications* * Vertical Mount - End-Drilled Head Horizontal Mount - Cross-Drilled Head 1/4-20 EZH370 5/16X2-1/4 NA NA 3/8-16 J EZH735 5/16X2-114 4" Steel, Wood or Concrete Vertical Mount - End-Drilled Head 1/4-20 EZG910 1/4-10X2 NA NA 3/8-16 EZG930 1/4-10X2 Horizontal Mount - Cross-Drilled Head 3/8-16 EZH935 1/4-10X2 NA NA All Materials - Adapter for Hanging 1/2" Rod' ED 1 1/2-13 EZE270 NA NA Simply install any 3/8° HangerMate anchor as required, then thread EZE270 adapter into... Use of adapter does not increase performance value of 3/8 HangerMate anchor. Check corresponding 3/8" anchor spec sheet for load-carrying capacity and add appropriate safety factor. Installation Tools EZE215 Drive Socket ______________ EZE220 Drive Sleeve EZE240 Drill Bit Adapter ctjJS3' EZE320 25/64 Drill Bit with Stop Collar EZE340 ANSI 1J4' Tanged Drill Bit for Hammer Drills ANSI 1/411 SDS EZE350 Drill Bit for Rotary Hammer Drills NOTE: It is the responsibility of the installer to determine the application-specific details under which a code approval or listing was granted. Contact Elco Construction Products for more information. EZE360 7/32 Tanged Drill Bit for Hammer Drills EZE380 7/32 SDS Drill Bit for Rotary Hammer Drills Tool for EZG580/ EZE290 EZG590/EZG600/ EZG610 components ELY100 Drill Bit Adapter for 7/32° drill bit * * Installation into Concrete/Masonry Applications Insert tanged bit (EZE340) in bit holder (EZE240), or use SDS bit (EZE350). Drill hole, then slide concrete drive socket (EZE220) over bit and onto hex. Insert anchor into socket and install. Parts can also be installed in concrete using standard 1/4" masonry bit to drill hole and use EZE215 drive socket to set anchor. Steel Applications Average Ultimate Value (lbs)* EMEMMMMMM End-Drilled Anchors EZG 160 I 1/4-201.1/4-20 786 1139 1738 23761 4694 5994 EZG450 3/8-1611/4-20 922 1351 2273 2488 N/A N/A EZG470 3/8-16 1/4-20 786 1139 1738 2376 4694 5994 EZG471 3/8-16 1/4-20 3435 4024 4279 4692 5812 5909 EZG490 3/8-16 1/4-20 786 1139 1738 2376 4694 5994 EZG491 3/8-16 1/4-20 3435 4024 4279 4692 5812 5909 EZG510 3/8-16 1/4-20 N/A N/A N/A N/A 3677 5207. EZG511 3/8-16 1/4-20 P 3435 4024 4279 4692 5812 5909 EZG530 3/8-16 1/4-20 786 1139 1738 2376 4694 5994 EZG540 3/8-16 1/4-20 786 111391 1738 2376 4694 5994 Cross-Drilled Anchors EZH155 1/4-2011/4-20 1739 1944 2420 2570 2809 2809 EZH455 3/8-.1611/4-20 1860 2071 2516 2606 N/A EZH475 3/8-16 1/4-20 1739 1944 2420 2570 2809 2809 EZH476 3/8-16 1/4-20 2756 2753 2809 2809 2809 2809 EZH495 3/8-16 1/4-20 1739 1944 2420 2570 2809 2809 EZH496 3/8-16 1/4-20 2756 2753 2809 28091 2809 2809 EZH515 3/8-16 1/4-20 N/A N/A N/A N/A 3529 3529 EZH516 3/8-16 1/4-20 2756 2753 2809 2809 2809 2809 EZH535 3/8-16 1/4-20 2756 2753 2809 2809 2809 2809 Product and Warranty Information Code listings and approvals require that HangerMatee anchors be installed with HangerMate drive sockets. Shoulders of installed HangerMate anchors must be flush to the metal, masonry or wood substrate materials. HangerMate anchors should not be subjected to vibratory or shock loads resulting from such applications as anchorings for reciprocating machinery, crane rails or hoists. Care should be taken to not damage HangerMate anchors or the substrate into which they are installed when loading pipe, installing cable tray, or otherwise suspending components from HangerMate anchors. Failure to do so may result in significant loss of holding power. As with all cutting tools and fasteners, normal safety precautions should be observed to avoid electrical installations, other utilities and reinforcement bars; careful use will provide the utmost safety and reliability. The wearing of safety glasses by users and persons in the vicinity is required by Federal Law. This literature was prepared as an introductory summary of the HangerMate threaded rod anchoring system from Elco Construction Products and is not, therefore, intended to describe all hazards, limitations, warnings, precautions, etc. pertaining to the use of the product. The information and data presented herein are believed to be accurate and reliable, however, due to the wide variety of possible intervening factors, the suitability of the product for the use intended is the sole responsibility of the user. Specifications and other information contained herein supersede all previously published material and are subject to change without notice. All HangerMate anchors are warranted to be manufactured free from defects in material and workmanship. Under this warranty, Elco Construction Products will provide, at no charge, replacement product for any HangerMate anchors proven to be defective when installed in accordance with our published recommendations and in applications considered by us as suitable for this product. This warranty is in lieu of any and all warranties, expressed or implied, and in no case will Elco Construction Products be liable for incidental, liquidated or consequential damages. Light-gage Steel API tiofls Max. Pipe Diameter 1 2.5 35 4- Min. Steel Thickness 1 22 ga. 1 18 ga 1 16 ga Ultimate Tensile Load' Gage 1 26 22 20 1 18 16 Ultimate Tensile Load 1 848 1025 1153 1 1410 1880 Wood Applications Average Ultimate Value (lbs)* End-Drilled Anchors EZG315 1/4-20 1 5/16-14 1 2487 1 2162 1 1768 EZG650 3/8-16 5/16-14 1 2487 1 2162 1 1768 EZG670 3/8-16 1 5/16-14 1 2487 1 2162 1 1768 Cross-Drilled Anchors EZH320 1 1/4-20 1 5/16-14 1 1801 1 1460 1 1451 EZH665 1 3/8-16 1 5/16-14 1 1801 1 1460 1 1451 Concrete Applications Average Ultimate Value (lbs)* End-Drilled Anchors EZG365 1 1/4-20 1 5/16-14 1 2188 EZG730 3/8-16 5/16-14 1 2188 Cross-Drilled Anchors EZH370 1/4-20 5/16-14 2767 EZH735 3/8-16 5/16-14 2767 HangerMate MP Anchors - End-drilled Product Only Average Ultimate Value (lbs) Application Material Performance Values: End-drilled Product Only Southern Pine 1541 16 ga. steel 880 14 ga. steel 1106 12 ga. steel 1754 1/8' steel 2505 Concrete (3300 psi) 2933 * Performance Testing Notes: The loads indicated are average ultimate values achieved under laboratory conditions and appropriate safety factors should be applied for design purposes. NFPA (National Fire Protection Assoc.) minimum fastening requirements are five times the weight of a 15 foot section of water filled pipe plus 250 lbs. This is 1475 lbs. for 4' pipe. All test values were obtained using 3/8-16 rod. When 1/4-20 rod is used, the strength of the rod may be less than the pull-out values of the anchors. Loads were determined by testing products in the orientation for which they were designed to be used. End-drilled parts were pulled in line with the anchor's axis while cross-drilled parts were tested with the force perpendicular to the axis. Elco Construction Products 1.800.435.7213 0 fax: 563.387.3540 www.elcoconstruction.com Gtfastech' . Avde1 IFomf HangerMate*, iForm and lnfastech are registered trademarks of lnfastech Intellectual Properties Pte Ltd. AvdelO is a registered trademark of Avdel Ilk Ltd. ©2011 Infastech Intellectual Properties Pte Ltd. All rights reserved. NFPAI3 PIPE ROD 1 M. 5 WT.+250 UL TEST LOAD 1 3/8 30.75 403.75 750 1 1/4 3/8 43.95 469.75 750 11/2 3/8 54.15 520.75 750 2 3/8 1 76.95 634.75 1 750 21/2 3/8 118.35 841.75 650 3 3/8 162.30 1061.50 1050 4 3/8 246.00 1480.00 1500 5 1/2 349.45 1996.75 2000 6 1/2 476.35 2631.75 2650 8 1 1/2 1 711.00 1 3805.00 1 4050 I thru 4 Inch pipe LISTED FOR STEELICPVC 112 & 3/4 Inch pipe 5 thru 8 Inch pipe P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 300 RING HANGER SIZE - ROD- 3/8" or 1/2" SIZE - SYSTEM PIPE - 1/2" thru 8" MATERIAL - Carbon Steel. FINISH - Mu. Galvanized to G-90 specification. LISTING/APPROVAL - '0203-EX 25511"- 8" Approval guide - 111- 8" OSHPD OPA-0601 See Website. um Conforms to Federal Specification WW-H- 17 1E type 10, and Manufacturers Standardization Society SP-69, type 10. MAXIMUM TEMPERATURE - 65 0°F. FUNCTION - Pipe component of an AFCON hanger. To support horizontal steel, CPVC or copper pipe. INSTALLATION - Per these instructions including NFPA 13 and the CPVC manufacturers instructions. FEATURES * Sized and listed exclusively for use with #310 Surge Restrainer. * Band edge is offset for EASY pipe insertion. * Custom fit swivel nut for better retention in ring. ORDERING - Part #, pipe size. PIPE A B I 1.8793 2.5259 1114 2.1382 2.7850 1 112 2.2873 2.9140 2 2.8048 3.2516 2112 2.7500 3.5080 3 30825 1 3.8205 4 3.5825 1 4.3205 5 4.0540 4.9397 6 4.6250 1 5.4707 8 7.5920 8.4077 9/15 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 310 RING RESTRAINER t Restraint SIZE - One size fits 3/4 thru 2 inch AFCON #300 Ring Hanger. MATERIAL - Carbon Steel. FINISH - Mu. Galvanized. LISTINGS - Sus 203-EX 2551 Listed only for use with AFCON #300 Ring Hanger. FUNCTION - To restrain movement of sprinkler pipe toward the knurl nut of the ring hanger. To prevent upward movement of pipe that supplies a pendent sprinkler below the ceiling. INSTALLATION - Per NFPA 13 and CPVC manufacturers instructions on steel, CPVC, or copper pipe. Snap into locking position on swivel nut of AFCON #300 Ring Hanger. SPECIAL NOTE: When installing on CPVC sprinkler system pipe: Verify that all assembly components are cleaned of any surface oil. FEATURES - * Listed only for use with AFCON #300 Ring Hanger. ORDERING - Part # and size. Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any director indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-AFCON products have been, or are used. 1/08 Can be installed on bar joists or 1-beams Thumb spring retainer allows for ease of positioning Snap-.off bolt head helps enable easy installation and inspection of seismic sway braces No assembly required No loose parts Meets NFPA-13 requirements for seismic sway bracing Material: Steel Finish: ELectrogalvanized c®us €> OSHPD APPROVED .. .: : • Flange Thickneis . . .. - ... . Part Number . A B C CSBBARJEG 1/4 - 1/2" 2" 3" 2 1/2" - ULLoads Brace Direction t Structure Service Pipe Size - Rating tt Parallel 1"- 10" 3.000 Lb Perpendicular 1" 12" . - ' 3.740 Lb FMLoads 4. Brace Direction' Horizontal Capacity per InstalLation AngLe fronVeticaL - --.. to Structure Service Pipe Size .. -- T. . .30°44°' V - '45°_59° - - VV•V ' - 60°-74° - - - - 75-90° Parallel N/A ._------------------------- 1.410 lb 2.110 Lb 2.540 lb 2,830 lb Perpendicular , N/A 1.740 Lb 1.710 IV.2.060 lb 2.300 Lb V FM is a registered certification mark of FM Approvals LLC. LTD. NFPA is a registered trademark of National Fire Protection Association, Inc. UL. UR. cUL. cUR, cULus and cURus are registered certification marks of UI.. LLC. WARNING V Pentair products shall be installed and used only as indicated in Pentair's product instruction sheets and training materials. Instruction sheets are available at erico.pentair.com and from your Pentair customer service representative. Improper installation, misuse, misapplication or other failure to completely follow Pentair's instructions and warnings may cause product malfunction, property damage. serious bodily injury and death and/or void your warranty. © 2017 Pentair Ali rights reserved Pentair. CADDY, CAD WELD. CRITEC, ERICO, ERI FLEX. ERITECH and LENTON are owned by Pentair or its global affiliates. Alt other trademarks are the property of their respective owners. Pentair reserves the right to change specifications without prior notice. +PENTAIR Universal design allows one product to attach directly to concrete, wood, bar joist or I-beam adapters Snap-off bolt head helps enable easy installation and inspection of seismic sway braces Use for both Lateral and longitudinal sway brace applications Works with 1" through 2" brace pipes and 1/4' angle iron braces to reduce inventory Center bolt does not require tightening Meets NFPA®-13 requirements for seismic sway bracing iflJ —1 SI— Material: Steel Finish: Electrogatvanized c®<Ei us > OSHPD APPROVED - ......t: Part . Hole Size 0 ............ l .. * C Number CSBUNIV050EG 9/16" 5 1/4' 4 15/8" C56UNIV075EG 13/16 . ...5 IN', .....•. .0• , 15./8. 0•• ... :-: .ULL i.:2 ..: tz.: Brace !ype ... , 0 -Seivice Pipe Size .. Ratung Pipe 1 - 10 3.000 lb 1/4 Thick Angle 1 8 2,015 Lb FM Loads J., - Horizontal Cpacity per Installation Angle from VeticaL Brace Type .Service Pipe Size - - ______________________________________________ 30°44° 45 59 60°-740.'75 90 Pipe N/A 1.620 Lb 2.300 lb 2.820 lb 3.140 lb FM is a registered certification mark of FM Approvals LLC, LTD. NFPA is a registered trademark of National Fire Protection Association, Inc. UL. UR. cuL. cuR. cULus and cuRus are registered certification marks of UL LLC. WARNING Pentair products shall be installed and used only as indicated in Penlairs product instruction sheets and training materials. Instruction sheets are available at erico.penlair.com and from your Pentair customer service representative. Improper installation, misuse, misapplication or other failure to completely follow Pentair's instructions and warnings may cause product malfunction, property damage, serious bodily injury and death and/or void your warranty. © 2017 Pentair All rights reserved Pentair. CADDY, CADWELD. CRITEC, ERICO, ERIFLEX. ERITECH and LENTON are owned by Pentair or its global affiliates. All other trademarks are the property of their respective owners. Pentair reserves the right to change specifications without prior notice. ___ +PENTAIR Use for both lateral and longitudinal sway brace applications Snap-off bolt head helps enable easy installation and inspection of seismic sway braces Works with 1 through 2" brace pipes and 1/4" angle iron braces to reduce inventory Slotted design grabs service pipe for added gripping strength Meets NFPA-13 requirements for seismic sway bracing Material: Steel Finish: ElectrogaLvanized c®us 4'8> OSHPD APPROVED CSBSTUO100EG 1" 67/8" 1" CSBSTUO125EG 11/4 7 3/8 1 CSBSTUO150EG 1 1/2 73/4' 1" CSBSTU0200EG 2 8 1/8 1,3/16" CSBSTU0250EG 2 1/2 87/8' 13/16" CSBSTUO300EG 3 9J8..1 3/16 CSBSTU0400EG 4" 10 5/8" 1 1/2" CSBSTU0500EG 5 12 1/8 11/2 CSBSTU0600EG 6" 135/8" 2" CSBSTUDBOOEG 8 153/4 2 CSBSTU1000EG 10" 18" 2 LJL Loads IListed for Restraints1741 Part Nuiber Dyna Flw® Service Pipe ; ' Sch"10STvice Pipe Sch 40 Service Pipe CSBSTII0100xx N/A 655 lb 655 lb CSBST90125xx 655 Lb 655 lb 6551b CSBSTlJ0150xx 655 lb 655 lb 655 lb ___0 PENTAIR J' ,, .. . I . Part Numbr - LØeraL LigttudiiiL Dyna Flow® Service Pipe EZ FLOWTM Service Pipe Sch 10 Service Pipe Sch 40 Service Pipe Dyna FLow® Service Pipe EZ FLDW Service Pipe Sch 10 Service Pipe Sch 40 Seriice Pipe CSBSTU0200xx 3.000 lb N/A 3.000 Lb 3.000 lb N/A N/A N/A N/A CSBSTtJ0250xx ' 3.000Lb . •N/A 3.000 Lb . . 3.000 Lb . 2.015 Lb N/A . 2.015 Lb 2.015 lb CSBSTU0300xx 3.000 Lb N/A 3.000 lb 3.000 Lb 2.015 Lb N/A 2.015 lb 2.015 lb CSBSTU0400xx 3000 Lb 3000 lb 3,000 Lb "21.0004 2015 Lb N/A 2015 lb 2.015 Lb CSBSTU0500xx N/A 3.000 lb 3.000 lb 3.000 lb N/A N/A - 2.015lb 2.015 lb CSBSTU04b0xx N/A 3.000 Lb 3,000 lb .3.000.1b .N/A :2015 Lb 2.015 lb 2.015 It; CSBSTU0800xx N/A N/A 3,000 Lb 3.000 Lb N/A N/A 2.015 lb 2.015 lb CSBSTU1000xx N/A N/A 3000 lb 3000 Lb N/A N/A,.3,000 Lb 3.000 Lb 2. _ FM Loads___ight(LSchiOnd Sch 40 Part Number Horiintal Capacityper InsLLiion ArgLe from VerticaL - LateraL Longitudinal ____..S..S.... '30 44 45 59° 60 14° 75° 90 '30_440 ______..-=•,,.-. 45 59 60° 74° 75 90° CSBSTU0100xx 860 lb 1.220 Lb 1.500 lb 1.670 lb 970 lb 720 lb 860 Lb 960 lb CS8STU0125xx 860 lb 1 220 lb 1 5001b 1,670 ibl. 970 Lb 720 Lb 860 Lb 960 Lb CSBSTtJ0150xx 860 lb 1.220 lb 1.500 lb 1.670 lb 970 Lb 720 lb 860 Lb 960 Lb CSBSTU0200xx 1.530 lb 2 160 Lb .2,650 Lb 2.960 Lb 870 Lb 690 Lb 830 Lb 930 Lb CSBSTU0250xx 1.530 Lb 2.160 Lb 2.650 Lb 2.960 Lb 870 Lb 690 lb 830 lb 930 lb CSBSTU0300xx . 1.530 lb 2,160 Lb: .. 2.650 Lb 2.960 Lb. .. 870 Lb i:.. 830 Lb . . 930 Lb - CSBSTU0400xx 1.570 lb 2.220 Lb 2.720 lb 3.030 lb 1.550 Lb 1.390 lb 1.680 Lb 1.870 lb C5BSTIJ0500xx 1 570 lb 2.220.1b., 2720 lb 3030 Lb 1 55o lb 690.1b....' 1 3901b"' 1 - .'680 lb 1 870 Lb CSBSTU0600xx 1.980 lb 2.810 lb 3.440 Lb 3.840 lb 1,470 lb 1,170 lb 1.410 Lb 1,570 Lb FMLods(0.188___ __ HorintaLCapacityperinstaLlationAngLefrom VerticaL -Lateral, - LongitudinaL Part Number - - 30 44] { 45° 59 60 74° 750 90 30 44°' 45° 59°F - ___60_____74 75° 90° CSBSTU0800xx 2.040 Lb 2.890 lb 3.540 lb 3.950 lb 1.200 lb 1.700 lb 2.090 lb 2.330 lb CSBSTU1000xx 2040 Lb 2.890 Lb 3540 Lb 3,956 lb 1200'11b 700 Lb j.706- 2.090 lb 2330 Lb Dyna-Flow is a registered trademark of Allied Tube & Conduit Corporation. FM is a registered certification mark of FM Approvals LLC. LTD. NFPA is a registered trademark of National Fire Protection Association. Inc. UL, UR. cUL. cUR, cULus and cURus are registered certification marks of UL LLC. WARNING Pentair products shall be installed and used only as indicated in Pentair's product instruction sheets and training materials. Instruction sheets are available at erico.pentair.com and from your Pentair Customer service representative. Improper installation, misuse, misapplication or other failure to completely follow Pentair's instructions and warnings may cause product malfunction, property damage, serious bodily injury and death and/or void your warranty. - © 2017 Pentair All rights reserved Pentair, CADDY, CAD WELD. CRITEC. ERICO. ERIFLEX. ERITECH and LENTON are owned by Pentair or its global affiliates. All other trademarks are the property of their respective owners. PentaiF reserves the right to change specifications without prior notice. OPENTAIR The Quick Grip Lateral Brace, part of the CADDY Line of fire sprinkler bracing systems from Pentair, is designed to help simplify installations when bracing service pipe for seismic or other catastrophic events. It features an innovative design for quick attachment of brace pipe to service pipe saving time and money. Easy two-step installation etminates extra trips between structure and service pipe Works with 1" and 1 1/4" (25 mm and 32 mm) brace pipes to reduce inventory Yellow tips provide a visual indicator that the bolts have been properly torqued Easy installation with an impact wrench from the bottom side of the clamp Meets NFPA-13 requirements for seismic sway bracing Material: Steel Finish: Electrogalvanized c@us <8> OSHPD APPROVED ParNLin ;PipeSi 4 : ' :" 4. CSBQG0250EG 2 1/2" 57/16 -57/8 63/4" CSBQG0300EG 3" : 6 1/8' -6 1/2' 71/2" CSBQG0400EG 4" 7 1/8 -7 1/2" 8 3/4" CSBQG0600E6' 6" 9 1/4" -:9 5/8- 11 3/4" CSBQG0800EG 8" 113/8" -11 13/16" 13 7/8 tjl Part Number '" Service Pipe Schedule . .."' 1 1 Brace Pipe 11/4 Brace Pipe CSB000250EG Dyna-Ftow® 2.015 lb 2.015 lb 10 2.015 lb 2.015 lb 40 2.015 Lb 2.015 lb CSBQG0300EG .......................... Dyna Flow® 2015 Lb 2015 lb 10 2,015 lb 2015 lb 40 20151b 20151b CSB060400EG Dyna-Ftow® 2.015 lb 2.015 lb 10 2.015 lb 2,015 1b 40 2.015 lb 2.015 lb +PENTAIR Part Number - - l Service Pipe Schedules ... LateraL r 1 Brace Pipe K. 1 1/4 Brace Pipe CSBQGO600EG Mega -Flow 2.015 lb 2.0151b 10 2.01516 2.015 Lb 40 2.015 lb 20151b CSBQG0800EG 10 2.015 Lb 2.015 Lb 40 2.015 lb 2.015 lb Part Number - Service Pipe Schedule LateraL - HorizotaiCpacitjer 1nita11atuon Angle Irm VeiicaL - '60° 74° 750 90° CSB06025OEG LightwaLl 1.410 lb 2.000 lb 2.450 lb 2.740 Lb 10 1.410 lb 2.000 lb 2.450 lb 2.740 lb 40 1.410 lb 2.000 lb 2,450 Lb 2.740 lb CSBQG0300EG LightwalL 1.190 lblv 1.6801b 2.060 lb 2.300 lb AD 1190 Lb 1.680 Lb 2.060 Lb 2300 Lb 40 ... 1.190 Lb., L680 Lb -. -, - .2.060Lb 2.300 lb CSBQG0400EG Lightwall 1.190 lb 1.680 lb 2.060 Lb 2.300 lb 10 1.190 lb 1.680 lb 2.060 lb 2.300 lb 40 1,190 lb 1.680 lb 2.060 Lb 2.300 lb CSBQG0600EG LightwaLl 8701b 1 230 lb 1 5101b. 1,690 lb 10 870.1b, :1,230 Lb 1.5 O lb 1 690 lb 40 1701b 1 370 Lb 1;680 Lb 1 870 lb CSBQGO800EG 0.188" IWaLl Thickness) 790 lb 1.110 lb 1.360 Lb 1.520 lb 40 790 lb 1.110 lb 1.360 Lb 1.520 lb Dyne-Flow is a registered trademark of Allied Tube & Conduit Corporation. FM is a registered certification mark of FM Approvals LLC, LTD. NFPA is a registered trademark of National Fire Protection Association. Inc. UL. (JR, cUl, cUR. cULus and cURus are registered certification marks of UL LLC. WARNING Pentair products shall be installed and used only as indicated in Pentair's product instruction sheets and training materials. Instruction sheets are available at erico.pentair.com and from your Pentair customer service representative. Improper installation, misuse, misapplication or other failure to completely follow Pentair's instructions and warnings may cause product malfunction, property damage, serious bodily injury and death and/or void your warranty. © 2017 Pentair All rights reserved Pentair, CADDY. CAD WELD, CRITEC, ERICO, ERIFLEX. ERITECH and LENTON are owned by Pentair or its global affiliates. At( other trademarks are the property of their respective owners. Pentair reserves the right to change specifications without prior notice. +PENTAIR Flexible Coupling - . . r -7 rc1 ••. - ;. L1JLI) I L 125 139.7 450 168 228 51 518X80-2 UL FM 5 5.500 3.10 6.61 8.98 2.01 165 168.3 450 200 265 52 518X85-2 UL FM 6 6.625 3.10 7.87 10.43 2.05 250 273.0 300 320 395.0 64 314X120-2 UL FM 10 10.750 2.07 12.60 15.55 2.52 Ught-duty Flexible Coupng NO eFu-Mech. MECH ..-- 1t i 4 C flI . ........ ••. . Li I -. :: ifljff jJ, - 25 33.1 500 55 92 42 318X55-2 UL FM 1 1.327 3.45 2.16 3.62 1.65 VdS LPCB 32 42.4 500 65 104 44 318X55-2 UL FM 1¼ 1.669 3.45 2.56 4.14 1.74 VdS LPCB 40 48.3 500 70 110 44 318x 55-2 UL FM 1¼ 1.900 3.45 2.75 4.33 1.74 VdS LPCB 50 60.3 500 83 124 44 318X55-2 UL FM 2 2.375 3.45 3.27 4.88 1.74 VdS LPCB 65 73.0 500 96 143 45 318X55-2 UI FM 2¼ 2.875 3.45 3.78 5.63 1.78 LPCB 65 76.1 500 100 145 45 318X552 UL FM 2¼ 3.000 3.45 3.94 5.71 1.78 VdS LPCB 80 88.9 500 115 160 45 1/2X70-2 UL FM 3 3.500 3.45 4.53 6.30 1.78 VdS LPCB 100 108.0 500 138 190 50 1/2X70-2 UL FM 4 4.250 3.45 5.43 7.48 1.97 LPCB 100 114.3 500 145 198 50 1/2X70-2 UL FM 4 4.500 3.45 5.71 7.80 1.97 VdS LPCB 125 133 450 162 225 51.0 5/8X80-2 UL FM 5 5.250 3.10 6.38 8.86 2.01 LPCB 125 139.7 450 169 230 52 5/8X80-2 UL FM 5 5.500 3.10 6.65 9.06 2.05 VdS LPCB 125 141.3 450 170 232 51 518X 80- 2 UL FM 5 5.563 3.10 6.69 9.13 2.01 LPCB 150 159.0 450 190 254 52 5/8X:85-2 UL FM 6 6.250 3.10 7.48 10.00 2.05 LPCB 150 165.1 450 196 260 52 UL FM 6 6.500 3.10 7.72 10.24 2.05 LPCB 150 168.3 450 200 265 52 x 5/8X85-2 UL FM 6 6.625 3.10 7.87 10.43 2.05 VdS LPCB 200 219.1 450 258 350 60 3 10115-2 UL FM 8 8.625 3.10 10.24 13.78 2.37 VdS LPCB 250 273.0 300 337 406 65 7/ X14 2 8 0- UL FM 10 10.150 2.07 13.27 16.00 2.56 VdS 300 323.9 300 372 460 64 718X140.2 UL FM 12 12.750 2.07 14.65 18.11 2.52 350 377.0 225 428 520 72 7/8X140-3 UL FM 14 14.842 1.6 16.85 20.45 2.85 400 426.0 225 476 570 1 73 7/8X140-3 UL FM 16 16.772 1.6 18.74 22.45 2.87 1G Rigid Coupling (iuiiiLi. L . 65 16.1 300 100 145 45 3!8X55-2 UL FM 2½ 3.000 2.01 3.94 5.52 1.77 80 88.9 300 1114 160 45 3/BX55-2 UL FM 3 3.500 2.07 4.50 6.30 1.78 100 108.0 300 . I M 4 4.250 2.07 5.30 7.28 1.97 100 114.3 300 ir - -TO 1/2X70-2 UL FM 4 4.500 2.07 5.51 7.36 1.91 125 139.7 300 16 1/2X75-2 UL FM 5 5.500 2.07 6.62 8.86 1.97 125 141.3 300 175 25 50 112X75-2 UL FM 5 5.563 2.07 6.69 8.86 1.97 150 6 _____1r90 6.250 300 2.07 7.48 9.92 1.97 5/8X80-2 UL FM 150 165.1 300 112X75-2 UL FM 6 6.500 2.07 7.68 9.84 1.97 150 168.3 300 UW 255 50 112X75-2 UL FM 6 6.625 2.07 7.87 10.04 1.97 200A 216.3 300 518X85-2 UL FM 8 8.516 2.07 10.04 12.60 2.28 200 219.1 300 -2 UL FM 8 8.625 2.07 10.05 12.68 2.28 250 273.0 300 ir 110 63 3/4X120-2 I FM 10 10.750 2.07 12.52 16.14 2.48 Light-duty Rigid Coupling JpUO £ S 0 Fu-Mech MECH WIDE CASTING MA . &ffi? At - --:: .______________ -_________ __________ _____________ _________ 25 33.7 500 59 105 44 318X55-2 UL FM 1 1.327 3.45 2.33 3.94 1.74 VdS LPCB 32 42.4 500 66 105 45 3!8X55-2 UL FM 1½ 1.669 3.45 2.60 4.13 1.78 VdS LPCB 40 48.3 500 72 112 45 318X55-2 UL FM 1½ 1.900 3.45 2.84 4.41 1.78 VdS LPCB 50 60.3 500 85 130 45 318X55-2 UL FM 2 2.375 3.45 3.35 5.12 1.78 VdS LPCB 65 73.0 500 98 140 45 318X55-2 UL FM 2½ 2.875 3.45 3.86 5.52 1.78 LPCB 65 76.1 500 101 145 45 318X55-2 UL FM 216 3.000 3.45 3.98 5.71 1.77 _________________ VdS LPCB 80 88.9 500 ii 168 46 112X70-2 UL FM 3 3.500 3.45 4.53 6.62 1.82 VdS LPCB 100 108.0 500 140 191 52 112X70.2 UL FM 4 4.250 3.45 5.51 7.76 2.05 LPCB 100 114.3 500 146 200 52 UL FM 4 4.500 3.45 5.75 7.88 2.05 112X70-2 VdS LPCB 125 133 450 165 226 52 5!8X85-2 UL FM 5 5.250 3.10 6.50 8.90 2.05 LPCB 125 139.7 450 110 235 52 518X85-2 UL FM 5 5.500 3.10 6.69 9.25 2.05 VdS LPCB 125 141.3 450 172 235 52 518X85-2 UL FM 5 5.563 3.10 6.77 9.25 2.05 LPCB 150 159.0 450 190 267 52 518X85-2 UL FM 6 6.250 3.10 7.48 1 10.51 2.05 LPCB 150 165.1 450 198 262 52 518X85.2 UL FM 6 6.500 3.10 7.80 10.32 2.05 LPCB 150 168.3 450 202.0 -65 iT 518X85.2 UL FM 6 6.625 3.10 7.95 10.43 2.05 VdS IPCB 200 219.1 450 260.0 342 62 3/4X115-2 UI FM 8 8.625 3.10 10.24 13.45 2.44 VdS LPCB 250A 267.4 300 318 396 63 3!4X120-2 UL FM 10 10.528 2.01 12.52 15.60 2.48 250 273.0 300 327 420 63 718X125-2 UL FM 10 10.750 2.07 12.88 16.54 2.48 LPCB 300A 318.5 300 364 456 63 7/8X140-2 UL FM 12 12.539 2.07 14.33 17.95 2.48 300 323.9 300 370 465 63 1/8X140-2 UL FM 12 12.750 2.07 14.57 18.30 2.48 350 355.6 300 415 510 Yi 7/8X140-3 UL FM 14 14.000 2.07 16.34 20.08 2.84 350 371.0 225 435 -r 72 718X140-3 FM 14 14.842 1.6 17.13 21.05 2.84 400 406.4 300 468 575 71 7!8X140-3 UL FM 16 16.000 2.07 18.43 22.64 2.84 400 426.0 225 490 592 72 1/8X140-4 FM 16 16.772 1.6 19.29 23.30 2.84 500 529.0 225 595 700 76 718X140-4 20 20.827 1.6 23.43 27.56 3.00 991 90° Elbow Light-duty 900 Elbow VIA- nef ___________ _______________ ___________________ 'I1'.JJD• . . 50 60.3 300 70 2 2.375 2.07 2.75 UIFMVdS 65 73.0 300 76 2½ 2.875 2.07 3.00 UL FM 65 76.1 300 76 ULFMVdS 2½ 3.000 2.07 3.00 80 88.9 300 85.5 3 3.500 2.07 3.37 UL FM Vd S 100 108.0 300 101 4 4.500 2.07 3.98 UL FM 100 114.3 300 101 4 4.500 2.07 3.98 ULFMVdS 125 139.7 300 124 5 5.500 2.07 4.88 UL FM VdS 150 159.0 300 140 6 6.500 2.07 5.50 ULFMVd S 150 165.1 300 140 6 6.500 2.07 5.50 UL FM 150 168.3 500 140 6 6.625 3.45 5.50 UIFMVdS 200 216.3 300 175 8 8.625 2.07 6.89 UL FM 200 219.1 300 165 8 8.625 2.07 6.50 UL FM VdS 4FM VOL PLO ;sø; O.Fu-Mech IVECH MEIDE CASTING - 25 33.7 500 57 UL FM 1 1.315 3.45 2.24 'MS 32 42.4 500 70 UL FM 1 Y 1.660 3.45 2.75 VdS 40 48.3 500 70 UL FM 1½ 1.900 3.45 2.75 VdS 50 60.3 500 82.5 UL FM 2 2.315 3.45 3.25 VdS 65 73.0 500 95 UL FM 2½ 2.815 3.45 3.14 65 76.1 500 95 UL FM 2½ 3.000 3.45 3.74 VdS 80 88.9 500 108 UL FM 3 3.500 3.45 4.25 VdS 100 114.3 500 121 UL FM 4 4.500 3.45 5.00 VdS 125 133.0 500 122 UL FM 5 5.250 3.45 4.80 125 139.7 500 140 UL FM 5 5.500 3.45 5.50 'MS 125 141.3 500 140 UL FM 5 5.563 3.45 5.50 150 165.1 500 165 UL FM 6 6.500 3.45 6.50 150 168.3 500 165 UL FM 6 6.625 3.45 6.50 VdS 200 219.1 500 197 UL FM 8 8.625 3.45 7.75 VdS 250 267.4 500 229 UL FM 10 10.528 3.45 9.00 250 273.0 500 229 UL FM 10 10.750 3.45 9.00 VdS 300 318.5 500 254 UL FM 12 12.539 3.45 10.00 300 323.9 500 254 UL FM 12 12.750 3.45 10.00 VdS 350 377.0 300 279 UL FM 14 1 14.84 1 2.07 10.98 1 400 426.0 300 305 UL FM 16 16.77 2.07 12.00 .-V4 - . . . . 25 33.7 500 57 UL FM 1 1.315 3.45 2.24 VdS 32 42.4 500 70 UL FM 1½ 1.660 3.45 2.75 VdS 40 48.3 500 70 UL FM 1½ 1.900 3.45 2.75 VdS 50 60.3 500 82.5 UL FM 2 2.375 3.45 3.25 VdS 65 73.0 500 95 UL FM 2½ 2.875 3.45 3.74 65 76.1 500 95 UL FM 2½ 3.000 3.45 3.74 VdS 80 88.9 500 108 UL FM 3 3.500 3.45 4.25 VdS 100 114.3 500 127 UL FM 4 4.500 3.45 5.00 VdS 125 133.0 500 122 UL FM 5 5.250 3.45 4.80 125 139.7 500 140 UL FM 5 5.500 3.45 5.50 VdS 125 141.3 500 140 UL FM 5 5.563 3.45 5.50 150 165.1 500 165 UL FM 6 6.500 3.45 6.50 150 168.3 500 165 UL FM 6 6.625 3.45 6.50 VdS 200 219.1 500 197 UL FM 8 8.625 3.45 7.15 VdS 250 267.4 500 229 UL FM 10 10.528 3.45 9.00 250 273.0 500 229 UL FM 10 10.750 3.45 9.00 VdS 300 318.5 500 254 UL FM 12 12.539 3.45 10.00 300 323.9 . 500 254 UL FM 12 12.750 3.45 10.00 VdS 350 377.0 300 279 UL FM 14 14.84 2.07 10.98 400 426.0 300 305 16 16.77 2.07 12.00 UL FM 130 Tee Light-duty Tee g SO /A CLO-4-Lo I CIL, MECHPFu-Mech . MEIDE CASTING 130S •TiT&': , . :j •, • . ,• • :. - 1"Ji'L.. • 50 60.3 300 70 ULFMVd S 2 2.375 2.07 2.75 65 73.0 300 76 UL FM 2½ 2.875 2.07 3.00 65 76.1 300 76 UL FM VdS 2½ 3.000 2.07 3.00 80 88.9 300 85.5 UL FM VdS 3 3.500 2.01 3.37 100 108.0 300 101 UL FM 4 4.500 2.07 3.98 100 114.3 300 101 ULFMVdS 4 4.500 2.07 3.98 125 139.7 300 124 ULFM VdS 5 5.500 2.07 4.88 150 159.0 300 140 ULF M VdS 6 6.500 2.07 5.50 150 165.1 300 140 UL FM 6 6.500 2.07 5.50 150 168.3 500 140 6 6.625 3.45 5.50 UL FM as 200 216.3 300 175 UL FM 8 8.625 2.07 6.89 200 219.1 300 175 UL F M VdS 8 8.625 2.07 6.89 3L U-Bolt Mechanical Tee FLwo M se Fu M ech - WI E C H MEIDE CASTING ....•wl: . .,. . . . . - .•. . ,. . crr-' -c 32X15 30 300 54.4 88.9 57.2 14X112 1.18 2.07 2.14 3.50 2.25 3!8X73 UL FM 32X20 30 300 54.4 88.9 512 1YiX3I4 1.18 2.07 2.14 3.50 2.25 318X73 UL FM 32X25 30 300 57.7 88.9 57.2 1ViX1 1.18 2.07 2.27 3.50 2.25 318X73 UL FM 40X15 30 300 57.4 88.9 57.2 1½X112 1.18 2.07 2.26 3.50 2.25 X73 UL FM 40X20 30 300 57.4 88.9 57.2 1VzX3I4 1.18 2.07 2.26 3.50 2.25 318X73 UL FM 40X25 30 300 60.8 88.9 57.2 14X1 1.18 2.07 2.39 3.50 2.25 318X7 UL FM 50X15 30 300 63.3 95.3 57.2 2X112 1.18 2.07 2.49 3.75 2.25 318X90 UL FM 50X20 30 300 63.3 95.3 57.2 2X314 1.18 2.07 2.49 3.75 2.25 3!8X90 UL FM 50X25 30 300 66.6 95.3 57.2 2X1 1.18 2.07 2.62 3.75 2.25 318X90 UL FM 65X15 30 300 69.9 108.0 57.2 ThX112 1.18 2.01 2.75 4.25 2.250 318X105 UL FM 65X20 30 300 69.9 108.0 51.2 215=4 1.18 2.07 2.75 4.25 2.250 318X105 UL FM 65X25 30 300 13.2 108.0 57.2 2VzX1 1.18 2.07 2.88 4.25 2.25 318X105 UL FM 65X15 30 300 69.9 108.0 51.2 76.1X1!2 1.18 2.07 2.75 4.25 2.250 318X105 UL FM 65X20 30 300 69.9 108.0 57.2 76.1X314 1.18 2.07 2.75 4.25 2.250 3/8X105 UL FM 65X25 30 300 73.2 108.0 57.2 76.1X1 1.18 2.07 2.88 4.25 2.25 318X105 UL FM 80X25 38 300 145 73 3X1 1.5 2.07 5.11 2.87 3.11 79 112X105 UL FM 100X25 38 300 185 72 89 4X1 1.5 2.07 7.28 2.83 3.50 1/2X125 UL F M 100X32 51 300 185 85 95 4X1 Vi 2.0 2.07 7.28 3.35 / 1/2X125 UL FM 100X40 51 300 185 85 95 4X1 2.0 2.07 7.28 3.35 3.74 112X125 UL FM 150X25 38 300 254 75 120 6X1 1.5 2.07 10.00 2.95 4.72 518X173 / UL FM 150X32 51 300 254 88 120 6X1¼ 2.0 2.07 10.00 3.46 4.72 5/8X173 UL FM 150X40 51 300 254 88 120 6X1Yz 2.0 2.07 10.00 3.46 4.72 5/8X173 UL FM - 0: -, . f .• r_ ___________ - _.,-,, •1 - ____ The AGF Manufacturing Inc. Model 1011 TESTANDRAIN® matches all the features and benefits of our Model 1000 by providing both the test function and the express drain function in a multistory installation for a wet fire sprinkler system. with the added feature of an integral Model 7000 Pressure Relief Valve with drainage piping. The Model 101 1A complies with the requirements of NFPA-13 that stipulate a pressure relief valve be installed on all gridded systems and downstream of all pressure reducing valves (see reverse). The Model 101 1A TESTANDRAIN® is a compact single handle ball valve which includes a tamper resistant test orifice and integral tamper resistant sight glasses, and is 300 PSI rated. Available in a full range of sizes from 34" to 2" NPT and BSPT, with all specifiable orifice sizes %" (2.8K), 7A6" (4.2K), ½" (5.6K), 17/32" (8.0K), 5/s" (11.2K, ELO), 34" (14.0K, ESFR), and K25 as required by NFPA 13, 2007 Edi- tion (see reverse). The included ULJFM Model 7000 Pressure Relief Valve features a flushing handle and is factory rated for 175 PSI. Other pressure settings are available and may be substituted. Designed to relieve excess system pressure caused by surges or temperature changes as well as solve the dif- ficult problem of providing the relief valve with a convenient drainage-piping outlet. Shipped with reef valve and bypass drain ports plugged to expedite pressure testing the system. A locking kit is available and can be ordered with the valve to provide vandal resistance or prevent unhten- tional alarm activation. Repair kits including (1) adapter gasket, (1) ball, (2) valve seats, (1) stem packing, and (1) stem washer are avail- able for all TESTANDRAIN® valves. Valve and orifice size must be specified when ordering. NOTE: It is important to note that the pressure rating of the relief valve indicates an operating range of pressure for both openirg and closing of the valve. Standard relief valves are required to OPEN in a range of pressure between 90% and 105% of their rating. The valves are required to CLOSE at a pressure above 80% of that rating. The relief valve should be installed where it is easily accessible for main- tenance. Care should 'be taken that the relief valve CANNOT be isolated from the system when the system is operational. A relief valve should NEVER have a shutoff valve or a plug downstream of its outlet. TESTANDRAIN is a registered trademark of AGF Manufacturing Inc. csioi 1A 10/09 MODEL 1011 - PLAN VIEW DIMENSIONS MODEL 1011 A - FRONT VIEW Orifice Size Available: 3/8", /ia, ½", 17/32", ELO (5/8)*, ESFR (3/4)*, & K25** SIZE A B C D E F G H 3/4" 7A6" 11/2" 23/16" 3%" 3 3/8" 11 i6" 49/16" 63/8" (191 mm) (37.5 mm) (57 mm) (93 mm) (86 mm) (46 mm) (117 mm) (162.5 mm) lit 79/m" 1½" 23/16" 3" 33/a" 11116" 49/16" 63/8" (191 mm) (37.5 mm) (57 mm) (93 mm) (86 mm) (46 mm) (117 mm) (162.5 mm) 11/4" 715/16" 111A6" 29/16" 41/4" 35/8" 115/16" 59/16" 51/2" (201 mm) (43 mm) (65 mm) (108 mm) (91 mm) (51 mm) (141 mm) (192 mm) 1½" 815/16" 113/16" 31/4" 51/16" 37/a" 25/8" 8¼" 10/8" (227 mm) (45 mm) (81.5 mm) (127 mm) (99 mm) (67 mm) (207 mm) (274 mm) 2" 815/16" 116" 1 3¼" 51/16" 3/8" 25/8" 8¼" I 107/8" (227 mm) (45 mm) (81.5 mm) (127 mm) (99 mm) (67 mm) (207 mm) (274 mm) *Available on 11/4" to 2" size units only "Available on 11h" and 2" size units only THE MODEL 1011 PROVIDES ALL OF THE FOLLOWING... From the 2007 Edition of NFPA 13 Chapter 8.16.2.4.1* Provisions shall be made to properly drain all parts of the system. ' 1rrrT Chapter 8.16.2.4.2 Drain connections, interior sectional or floor control valve(s) - & 8.16.2.4.3 shall be provided with a drain connection having a minimum size as shown in Table 8.16.2.4.2. MATERIALS Chapter 8.16.2.4.4 Drains shall discharge outside or to a drain capable of handling Handle: Steel the flow of the drain. Stem: Rod Brass Chapter A.8.17.4.2 (Wet Pipe System) test connection is permitted to terminate into Ball: C.P. Brass a drain capable of accepting full flow.., using an approved sight Body: Bronze test connection containing a smooth bore corrosion-resistant Valve Seat: Impregnated Teflon® orifice giving a flow equivalent to one sp(nkler... Indicator Plate: Steel Chapter 8.17.4.2.2 The test connection valve shall be readily accessible. Relief Valve: Bronze Chapter 8.17.4.2.4 shall be permitted to be installed in any location.., downstream Bypass Fittings: Brass of the waterf low alarm. Bypass Tubing: Nylobraid Chapter 8.17.4.3.1 (Dry Pipe System) a trip test connection not less than 1" in diameter, terminating in a smooth bore corrosion-resistant orifice, APPROVALS to provide a flow equivalent to one sprinkler... UL and ULC Listed: (EX4019 Chapter 8.17.4.3.2 The trip test connection... with a shutoff valve and plug not less & EX4533) than 1", at least one of which shall be brass. FM Approved Chapter 7.1.2 - a gridded wet pipe system shall be provided with a relief valve NYC-BSA No. 720-87-SM set to operate at 175 PSI or 10 PSI in excess of the maximum system pressure, whichever is greater. Chapter 8.16.1.2.3* A relief valve of not less than ½" in size shall be provided on the discharge side of the pressure-reducing valve set to operate at a pressure not exceeding 175 PSI. Chapter A.8.16.1.2.3 - consideration should be given to piping the discharge from the MADE IN U. H. (pressure relief) valve F3i1 ti .r. Oth6r,,,F6tdfits - AGF Manufacturing Inc. Job Name:____________________________ 100 Quaker Lane, Malvern, PA 19355 Phone: 610-240-4900 Architect: Fax: 610-240-4906 Engineer: www.testandrain.com Contractor: Specifications Size : 21/2", 3"Y' 6" Working Pressure : 300 psi (21.5 Bars) Test Pressure : 600 psi (43.0 Bars) Working Temperature : -.250 'F (-120'c) Factory Installed UL Approved Tempered Switch for Indoor and Outdoor Use Materials Body : Ductile Iron, Nylon-il Coated Disc : AL-Bronze, Ductile Iron, EPDM Encapsulated Stem : Stainless Steel, Hardened & Tempered Housing : Ductile Iron (ASTM A-536) Hand Wheel : Ductile Iron (ASTM A-536) Dimensions (Unit:mnVinch) SizeFA SI C .D 1E IF C H 21a"i1168(4.48)144.4(1.15) 1OTh(424) 131l(2) 1.8(52) 990(3) 1460(633)IK0OI3.94} 3 }13(4.13) 44.4(135) 1010(424) Buim 1463(536) .0(3) 1I0(4.13I 1tD0(94) 4"J145513)l.15) 1072(4241114314.9D) 1115(635) 990(32)) 1460(4.13) 1460094) 6" 1195(701)I5a5(2.11) 1410(539) 1463(6) 2145(&45) 1461(4) 13(446I 10(5) Indoor and Outdoor Use UL ULC Listed and FM Approved UL, ULC Listed & FM Approved Specifications Size 2", 21/2", 3". 4!'& 6" Working Pressure : 300 psi (21.5 Bars) Test Pressure 600 psi (43.0 Bars) Working Temperature : - 250°F(- 120"C) Install in Both Horizontal or Vertical Position Materials Body Ductile Iron (ASTM A-536) Seat Ring : Brass (ASTM C31100) Clapper Stainless Steel (ASTM A-240-304) Rubber Ring EPDM Srping : Stainless Steel (ASTM A-240-304) Hinge Pin : Stainless Steel (ASTM A-240-304) Flow Duelo Friction Loss Curves Friction Loss Grooved Check Valve( Water at 65"F) i-' 90 w 8D 7.0 . 6.0 .E 5.0 4.0 Cr 3.0 U 0. 2.0 0. Ii 0 2 i "0 2 0.9 0.8 0.7 0.6 Z - 100 200 300 400 500 700 1000 2000 3000 Flow rate in gallons per minute (GPM) Dimensions unit; inch (mm), Lb (Kg) SIZE '. 'OD A ,,B C ;4 1 0 2, 1 Dia E DaF" 'WtlLb/kgl I 2.37(603) 6.34 (161.0) 3.54(90.0) 2.80 (71.0) 5.02 (127.5) 2.37(60.3) 421 (107.0) 624(2.83) 2 1/2" 2.87(73.0) 7.06 (179.4) 3.91 (99.4) 3.19(81.0) 5.71 (145.1) 2.87(73.0) 4.74 (120.3) 8.80(4.00) 3.51 (89.1) 7.80 (198.0) 4.290 % 09.0) 3.61 (91.) 6.44(163.6) 3.51 (89.1) 5.24 (133.0) 13.23 (6.00) 4.50 (114.3) 8.62 (218.9) 1 10.38 4.06 (103.1) 4.25 (108.0) 7.71 (195.9) 4.50 (114.3) 6.49 (164.8) 19.84 (9.00) 6 6.63 (168.3) (263;6) 5.12 (130.0) 5.43 (137.9) 9.561242.9) 6.63 (168.3) 8.1111 (2113.7) 371R (17 nn) F P P I Description FPPI's complete line of TrimFit Forged Brass*, Full Port Ball Valves feature forged components machined to exacting specifications. Listed for fire sprinkler systems for trim, test or drain applications, our Full Port Ball Valves are rated 600 PSI for sizes ½" - 11/2" IPS and 300 PSI for the 2" size. Each valve is complete with plastic coated valve handle marked as required by UL. Blow out proof stem. Installation Specifications Installation practices consistent with those of the fire sprinkler industry are appropriate for the installation of this product. Always make sure to properly Nomenclature and Material: "hold back" the valve and each component being installed to the valve to prevent Part: Material: over tightening or stressing of the valve body. It is also necessary to make sure Nut Steel all components are in proper alignment in the assembly where the ball valve is Handle Steel Stem Gland Brass* present. Improper alignment of attached components may create stress on the Stem Packing PTFE valve leading to valve failure. Use a suitable thread sealant such as PTFE tape or Stem Brass* PipeFit Thread Sealant Paste with PTFE. Never use tape and paste together. Body Forged Brass* We do not recommend the use of anaerobic sealants with this product. The Ball Disc Pack Disc PTFE Ball Chrome Plated materials used in this sealant type are highly caustic and may cause failure of the Brass or synthetic components present in this product. Forged Brass* End Plug Forged Brass* *UUULC Listed 2R97 Part No.: Size: Take-Out: 06-838-00 ¼" IPS 111/16" DO NOT USE MORE THAN ONE SEALANT TYPE PER THREADED 06-840-00 /2" 21A6" 06-842-00 3/4" 2%" CONNECTION. DO NOT OVER TIGHTEN THREADS. OVER TIGHTENING WILL 06-844-00 2W' CAUSE LEAKS IN THIS AND OTHER THREADED COMPONENTS. 06-845-00 1%" 3V16" 06-846-00 1½" 313A6" 06-848-00 4%" *Full port valves have slightly larger "take out" dimensions than standard port valves. You may need to adjust trim components accordingly. *Contains lead. Not for use in 3198 LIONSHEAD AVE water systems intended for human consumption. CARLSBAD, CA 92010 TEL+ 1760599-1168 D +1800344-1822 FAX-i-1800344-3775 C & us 0 2015 Fire Protection Products, Inc. LISTED APPROVED 50 ARGCO 0-300 psi water 0-300 Psi air 0-300 Psi air/water AR... GUARANTEED Fire Sprinkler Pressure Gauges Application: Fluid medium which does not clog connection port or corrode copper alloy. Specifically designed for the fire sprinkler industry. Size: 4" (100 mm) Accuracy ± 3/2/3% of span (ASME B40.1 Grade B) Working Range Steady: 3/4 of full scale value Fluctuating: 2/3 of full scale value Short time: full scale value Operating Temperature Ambient: -40°F to 140°F (-40°C to 60°C) Media: max. 140°F (+60°C) Approvals UL listed (UL-393) FM approved Meets NFPA 25 Standards Temperature Error Standard Scale Additional error when temperature changes from reference temperature of 68°F (20°C) +0.4% for every 18° F (10°C) rising or falling. Percentage of span. PSI Window Standard Features Connection Material: copper alloy Acrylic, ultrasonically welded to case Lower mount (LM) - not available for 11h" size Standard Series • Type 110.1Osp 1/4° NPT limited to wrench flat area Bourdon Tube: Material: copper alloy C-type Movement: Copper alloy, silicone dampened Order Options Dia: White plastic with stop pin - black & red lettering water Pointer: Black aluminum air/water Case: Black polycarbonate air The information contained herein is produced in good faith and is believed to be reliable but is for guidance only. ARGCO and its agents cannot assume liability or responsibility for results obtained in the use of its product by persons whose methods are outside or beyond our control. it is the user's responsibility to determine the suitability of any of the products, methods of use, or preparation prior to use, mentioned in our literature, it is the user's responsibility to observe and adapt such precautions as may be advisable for the protection of personnel and property in the handling and use of any of our products. FOR MORE INFORMATION CALL ARGCO AT 1-800-854-1015 OR LOG ONTO WWW.ARGCO.COM Notes: Minimum dB ratings are calculated from integrated sound pressure measurements made at Underwriters Laboratories as specified in UL Standard 464. UL temperature range is -300 to 150°F (-34° to 66°C). Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels in an actual installation. SIZE INCHES (mm) VOLTAGE MODEL NO. STOCK NO. CURRENT TYPICAL dB AT 10 Ft (3m) (2) MINIMUM dB AT 10 Ft (3m) (1) 6(150) 12VDC PBD126 1706012 .12A 85 76 8(200) 12VDC PBD128 1708012 .12A 90 77 10(250) 12VOC PBD1210 1710012 .12A 92 78 6(150) - 24VDC PBD246 1706024 .06A 87 77 8 (200) 24V0C PBD248 1708024 .06A 91 79 10 (250) 24VDC PBD2410 1710024 .06A 94 80 6(150) 24VAC PBA246 1806024 .17A 91 78 8(200) 24VAC PBA248 1808024 .17A 94 77 10(250) 24VAC PBA2410 1810024 .17A 94 78 6(150) 120VAC PBA1206 1806120 .05A 92 83 8(200) 120VAC PBA1208 1808120 .05A 99 84 10 (250) 120VAC PBA12010 1810120 .05A 99 86 ldda?bhl BELLS (P) POTTER PBA-AC & PBD-DC The Symbol of Protection UL Listed Sizes Available: 6" (150mm), 8" (200mm) and 10" (250mm) Voltages Available: 24VAC I2OVAC I2VDC (10.2 to 15.6) Polarized 24VDC (20.4 to 31.2) Polarized Service Use: Fire Alarm General Signaling BurglarAlarm Environment: Indoor or outdoor use (See Note 1) -40° to 150°F (40° to 66°C) (Outdoor use requires weatherproof backbox.) Termination: 4 No. 18 AWG stranded wires 6" BELL SHOWN Finish: Red powder coating Optional: Model BBK-1 weatherproof backbox These vibrating type bells are designed for use as fire, burglar or general signaling devices. They have low power con- sumption and high decibel ratings. The unit mounts on a standard 4" (101 mm) square electrical box for indoor use or on a model BBK-1 weatherproof backbox for outdoor applications. Weatherproof backbox model BBK-1, Stock No. 1500001. ALL DC BELLS ARE POLARIZED AND HAVE BUILT-IN TRANSIENT PROTECTION: Potter Electric Signal Company '2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 888-882-1833' www.pottersignaI.com PRINTED IN USA Mlcr. #8850001 - REV S PAGE 1 OF 2 MFG. #5400776 -5/05 BELLS (R)POTTER PBA-AC & PBD-DC The Symbol of Protection DIMENSIONS INCHES (mm) FIG. I BELLS FIG. 2 WEATHERPROOF BACKBOX BOXHASONETHREADED 1/2"CONDUITEWTRANCE - 10 (250) 1_(110) 2 11/16 DRO. 1776-I (68) DWG. 11776-2 FIG. 3 WIRING (REAR VIEW) D.C. BELLS (OBSERVE POLARITY) A.C. BELLS RED (IN) FROM CONTROL PANEL RED (OUT) WHITE (IN) WHITE (CUT) OR DAD-OF-UNE OR OR TO NEXT BELL FROM CONTROL PANEL BLACK (OUT) PRECEDING BELL RESISTOR PRECEDING BELL BLACK (IN) ___________ BLACK (OUT) BLACK (IN) CAUTIOrk WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN. NOTES: OBSERVE POLARITY TO RING D.C. BELLS. RED WIRES POSITIVE (+) BLACK WIRES NEGATIVE (-) CAUTIO WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN. NOTES- WHEN USING A.C. BELLS. TERMINATE EACH EXTRA WIRE SEPARATELY AFTER LAST BELL END-OF-UNE RESISTOR IS NOT REQUIRED ON A.C. BELLS. DWG. #776-3 INSTALLATION The bell shall be installed in accordance with NFPA 72 or local Ahj.-The top of the device shall be no less than 90" Aff and not less than 6" below the ceiling. Removethegong. Connect wiring (see Fig. 3). Mount bell mechanism to backbox (bell mechanism must be mounted with the striker pointing down). Reinstall the gong (be sure that the gong positioning pin, in the mechanism housing, is in the hole in the gong). Test all bells for proper operation and observe that they can be heard where required (bells must be heard in all areas as designated by the authority having jurisdiction). PRINTED IN USA MKT. #8850001 . REV S PAGE 2 OF 2 MFG. #5400776.5/05 ®Popuffm VANE TYPE WATERFLOW The Symbol of Protection ALARM SWITCH WITH RETARD Specifications subject to change without notice. Ordering Information Nominal PipeSize Model Part Number DN50 VSR-2 1144402 21/211 DN65 VSR-2 1/2 1144425 DN80 VSR-3 1144403 31/211 - VSR-3 1/2 1144435 DNIOO VSR-4 1144404 - VSR-5 1144405 DNISO VSR-6 1144406 8" DN200 VSR-8 1144408 Optional: Cover Tamper Switch Kit, stock no. 0090148 Replaceable Components: Retard/Switch Assembly, stock no. 1029030 General Information The Model VSR is a vane type waterfiow switch for use on wet sprinkler systems. It is UL Listed and FM Approved for use on steel pipe; schedules 10 through 40, sizes 2" thru 8" (50 mm thru 200 mm). LPC approved sizes are 2" thru 8" (50 mm thru 200 mm). See Ordering Information chart. The VSR may also be used as a sectional waterfiow detector on large systems. The VSR contains two single pole, double throw, snap action switches and an adjustable, instantly recycling pneumatic retard. The switches are actuated when a flow of 10 GPM (38 LPM) or more occurs downstream of the device. The flow condition must exist for a period of time necessary to overcome the selected retard period. UL, CUL and CSFM Listed, FM Approved, LPCBApproved,For CE Marked (EN12259-5) /VdS Approved model use VSR-EU Service Pressure: 450 PSI (31 BAR) - UL Flow Sensitivity Range for Signal: 4-10 GPM(15-38 LPM)- UL Maximum Surge: 18 FPS (5.5 m/s) Contact Ratings: Two sets of SPDT (Form C) 10.0 Amps at 125/250VAC 2.0 Amps at 3OVDC Resistive 10 mAmps mm. at 24VDC Conduit Entrances: Two knockouts provided for 1/2" conduit. Individual switch compartments suitable for dissimilar voltages. Environmental Specifications: NEMA4/IP54 Rated Enclosure suitable for indoor or outdoor use with factory installed gasket and die-cast housing when used with appropriate conduit fitting. Temperature Range: 40°F - 120°F, (4.5°C - 49°C) - UL Non-corrosive sleeve factory installed in saddle. Service Use: Automatic Sprinkler NFPA- 13 One or two family dwelling NFPA-13D Residential occupancy up to four stories NFPA-13R National Fire Alarm Code NFPA-72 Installation must be performed by qualified personnel and in accordance with all national and local codes and ordinances. Shock hazard. Disconnect power source before servicing. Serious injury or death could result. Risk of explosion. Not for use in hazardous locations. Serious injury or death could result. I CAUTION I Waterfiow switches that are monitoring wet pipe sprinkler systems shall not be used as the sole initiating device to discharge AFFF, deluge, or chemical suppression systems. Waterfiow switches used for this application may result in unintended discharges caused by surges, trapped air, or short retard times. Enclosure The VSR switches and retard device are enclosed in a general purpose, die-cast housing. The cover is held in place with two tamper resistant screws which require a special key for removal. A field installable cover tamper switch is available as an option which may be used to indicate unauthorized removal of the cover. See bulletin number 5401103 for installation instructions of this switch. RUNT EDIN USA MFG. #5401146- REV L PAGE lOF4 3/09 VSR ® POTTER VANE TYPE WATERFLOW The Symbol of Protection ALARM SWITCH WITH RETARD Installation (see Fig. 1) These devices may be mounted on horizontal or vertical pipe. On horizontal pipe they shall be installed on the top side of the pipe where they will be accessible. The device should not be installed within 6" (15 cm) of a fitting which changes the direction of the waterfiow or within 24" (60 cm) of a valve or drain. NOTE: Do not leave cover off for an extended period of time. Drain the system and drill a hole in the pipe using a hole saw in a slow speed drill (see Fig. I). Clean the inside pipe of all growth or other material for a distance equal to the pipe diameter on either side of the hole. Roll the vane so that it may be inserted into the hole; do not bend or crease it. Insert the vane so that the arrow on the saddle points in the direction of the waterfiow. Take care not to damage the non-corrosive bushing in the saddle. The bushing should fit inside the hole in the pipe. Install the saddle strap and tighten nuts alternately to required torque (see the chart in Fig. I). The vane must not rub the inside of the pipe or bind in any way. A CAUTION Do not trim the paddle. Failure to follow these instructions may prevent the device from operating and will void the warranty. DO NOTI.EA VE COVER OFF FOR Retard Adjustment Fig. 1 IV 'V . XTENDLD PERIOD OT liME The delay can be adjusted by rotating the retard adjustment knob from 0 to the max setting (60-90 seconds). The time delay should be set at the minimum required to prevent false alarms CAUTION Hole must be drilled perpendicular to the pipe and vertically centered. Refer to the Compatible Pipe/Installation Requirements chart for size. Correct Incorrect TIGHTEN NUTS MOUNT ON PIPE SO ARROW ON SADDLE POINTS IN DIRECTION OF WATERFLOW DIRECTION OF WATERFLOW ROLL PADDLE IN OPPOSITE DIRECTION OF WATERFLOW (Flowing water activates device in one direction only.) OWn. 1146-I1 I) l ADAPTERQADAITER 20mm 2mun MAX. DNSO ONLY USE (2)5130162 ADAPTERS AS SHOWN ABOVE D%VGt, uI4.IF Compatible Installation _Pipe/ _Requirements Model Nominal Pipe Size Nominal Pipe O.D. Pipe Wall Thickness Hole Size U-Boll Nuts Torque Schedule 10 (UL) Schedule 40 (UL) BS-1387 (LPC) I DN (VDS) inch mm inch mm inch mm inch mm inch mm inch mm inch mm ft-lb n-in VSR-2 2 DN50 2.375 60.3 0.109 2.77 0.154 3.91 0.142 3.6 0.091 2.3 1.25+125/-062 20 27 VSR-2 112 2.5 - 2.875 73.0 0.120 3.05 0.203 5.16 - - - - 1/2 - DN65 3.000 76.1 - - 33.0.+2.0 VSR-2 - - 0.142 3.6 0.102 2.6 VSR-3 3 DN80 3.500 1 88.9 0.120 3.05 0.216 5.49 0.157 4.0 0.114 2.9 2.00*125 50.8:k 2.0 VSR-3 1/2 3.5 - 4.000 101.6 0.120 3.05 0.226 5.74 - - - - VSR4 4 - DNIOO 4.500 - 114.3 - 0.120 3.05 - 0.237 6.02 - 0.177 - 4.5 - 0.126 - 3.2 VSR-5 5 - 5.563 141.3 0.134 3.40 0.258 6.55 - - - - VSR-6 6 DNISO 6.625 168.3 0.134 3.40 0.280 7.11 0.197 5.0 0.157 4.0 VSR-8 8 DN200 8.625 219.1 0.148 3.76 0.322 8.18 0.248 6.3 0.177 4.5 NOTE: For conner or olastic Dine use Model VSR-CF. PRINTED IN USA 'J -[i rit'i DVI 1141-I4 Fig. 7 Mounting Dimensions 3.50 in 2.00 mm) (50.8 234___(89.0 (59.4 mm) ' PIPE DIA. U-BOLT NUT + 5.25 in (+133.4 mm) U-BOLT WASHER PIPE SADDLE PIPE PLASTIC PADDLE NOMINAL PIPE DIA. +1.75 in (+44.5 MM) FOR DN 50— DN 652-2.5 in NOMINAL PIPE DIA. +2.125 in 054.0 MM) FOR DN 80— ON 200 3-8 in Fig. 8 GREEN GROUND VSR UP POTTER VANE TYPE WATERFLOW The Symbol of Protection ALARM SWITCH WITH RETARD Fig. 2 Fig. 3 Fig. 4 Switch Terminal Connections Clamping To remove knockouts: Place screwdriver at Break out thin section of cover when Plate Terminal inside edge of knockouts, not in the center, wiring both switches from one conduit entrance. 00 O 14 uninsulated section of a single conductor should not be looped md the terminal and serve as two separate connections. The must be severed, thereby providing supervision of the nection in the event that the wire become dislodged from under terminal. Failure to sever the wire may render the device ,erable risking severe property damage and loss of life. not strip wire beyond 3/8' of length or expose an uninsulated ductor beyond the edge of the terminal block. When using nded wire, capture all strands under the clamping plate. NOTICE Do not drill into the base as this creates metal shavings which can create electrical hazards and damage the device. Drilling voids the warranty. 1-13 Fig. 5 Typical Electrical Connections BEL Notes POWER SOURCE I. The Model VSR has two switches, one can be used to operate a central SUITABLE FOR BELL station, proprietary or remote signaling unit, while the other contact is used to operate a local audible or visual annunciator. A condition of LPC Approval of this product is that the electrical E~l entry must be sealed to exclude moisture. -1 1ffR WATER1LOW ZONE For supervised circuits, see "Switch Terminal Connections" ON FIRE PANEL drawing and warning note (Fig. 4). Testing The frequency of inspection and testing for the Model VSR and its associated protective monitoring system shall be in accordance with applicable NFPA Codes and Standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). If provided, the inspector's test valve shall always be used for test purposes. If there are no provisions for testing the operation of the flow detection device on the system, application of the VSR is not recommended or advisable. A minimum flow of 10 GPM (38 LPM) is required to activate this device. Advise the person responsible for testing of the fire protection system that this system must be tested in accordance with the testing instructions. PRINTED IN USA MFG. #5401146. REV L PAGE 3 OF 4 3/09 VSR up POTTER VANE TYPE WATERFLOW The Symbol of Protection ALARM SWITCH WITH RETARD Maintenance Inspect detectors monthly. If leaks are found, replace the detector. The VSR waterfiow switch should provide years of trouble-free service. The retard and switch assembly are easily field replaceable. In the unlikely event that either component does not perform properly, please order replacement retard switch assembly stock #1029030 (see Fig. 6). There is no maintenance required, only periodic testing and inspection. Retard/Switch Assembly Replacement (See Fig. 6) The Retard/Switch Assembly is field-replaceable without draining the system or removing the waterfiow switch from the pipe Make sure the fire alarm zone or circuit connected to the waterfiow switch is bypassed or otherwise taken out of service. Disconnect the power source for local bell (if applicable). Identify and remove all wires from the waterfiow switch. Remove the (2) mounting screws holding retard/switch assembly to the base. Do not remove the (2) retard housing screws. Remove the retard assembly by lifting it straight up over the tripstem. Install the new retard assembly. Make sure the locating pins on the retard/switch assembly fit into the locating pin bosses on the base. Re-install the (2) original mounting screws. Reconnect all wires. Perform a flow test and place the system back in service. Fig.6 REMOVE (2) ORIGINAL MOUNTING SCREWS HOLDING RETARD/SWITCH .VZASSEMBLYTO BASE BREAKOUTTHINSECTIONOFCOVER WHEN WIRING BOTH SWITCHES FROM ONE CONDUIT ENTRANCE. (2) ORIGINAL MOUNTING RETARD/SWITCH ASSEMBLY r CREWS (2) LOCATING DO NOT REMO' (2) RETARD HO SCREWS (2) LOCATING P11 BOSSES IN BASE DWG# 1146-10 Removal of Waterif ow Switch To prevent accidental water damage, all control valves should be shut tight and the system completely drained before waterfiow detectors are removed or replaced. Turn off electrical power to the detector, then disconnect wiring. Loosen nuts and remove U-bolts. Gently lift the saddle far enough to get your fingers under it. With your fingers, roll the vane so it will fit through the hole while continuing to lift the waterfiow detector saddle. Lift detector clear of pipe. PRINTED IN USA MFG. #5401146-REV L PAGE 4 OF 4 3/09