HomeMy WebLinkAbout2081 FARADAY AVE; ; FA1200559/12/23, 2:36 PM FA120055 Permit Data City of Carlsbad Fire Alarm Permit Job Address: 2081 FARADAY AV Permit Type: FALARM Parcel No: 2121202600 Lot #: 0 Reference No.: Permit No: FA120055 Status: APPROVED Applied 12/5/2012 Approved: 12/17/2012 Issued: 12/17/2012 PC #: Inspector: Project Title: SKLZ PRO PERFORMANCE TI ADD F.A. NOTIFICATION DEVICES TO EXISTING SYSTEM FOR T.I. WORK TO EXISTING INTERIOR. Applicant: Owner: SDA SECURITY SYSTEMS BIODECLLC 2054 STATE ST P 0 BOX 230931 SAN DIEGO CA ENCINITAS CA 619 239-3473 Fees ($) Add'I Fees ($) Total ($) Balance ($) 364 0 364 0 about:blank 1/1 FA 1-oo5 FIRE ALARM AND EMERGENCY COMMUNICATION SYSTEM RECORD OF COMPLETION To be completed by the system installation contractor at the time ofsystem acceptance and approval. It shall be permitted to mod(fy this form as needed to provide a more complete and/or clear record Insert N/A in all waned lines. Attach additional sheets, data, or calculations as necesiar, to provide a complete record I. PROPERTY INFORMATION Name of property: SKLZ Pro Performance Address: 2081 Faraday Ave Description of prcpc!ty. WarehouseIshipping. Occupancy type: B, SI Name of property representative: Nick Fousslanes Address: 2081 Faraday Ave Phone: 1-858-231-1691 Fax: E-mail: Authority having jurisdiction over this property- City of Carlsbad Phone: 760-802-4660 Fax: E-mail: INSTALLATION, SERVICE, AND TESTING CONTRACTOR INFORMATION Installation contractor for this SDA Security Address: 2054 State St, San Diego Ca 92101 License or certification number: C-7/C-10 245668 Phone: 1-600-896-1144 Fax: 619-338-1208 E-mail: Service organization for this equipment: Same Address: License or certification number Phone: Fax: Email: A contract for test and inspection in accordance with NFPA standards is in effect as of: Contracted testing company: Same Address: Phone: Fax E-mail Contract expires: Contract number: Frequency of routine inspections: DESCRIPTION OF SYSTEM OR SERVICE Fire alarm system (nonvoice) Fire alarm with in-building fire emergency voice alarm communication system (EVACS) D Mass notification system WS) D Combination system, with the following components: D Fire alarm 0 EVACS 0 MNS 0 Two-way, in-building, cmeigcncy communication system 0 Other (specify); NFPA 72, Fig. 10.18.2.1.1 (p. 1 of 12) Ccp)rght 02009 NaSanal Fe PrcUctlanAaacIicn. ThiaCnn nay be aWWforhalMduai tue otherthaUor resale. It may not be copied far canunuiclal sais uid1b1bu5an. It p 3. DESCRIPTION OF SYSTEM OR SERVICE (continued) NFPA 72 edition: 2010 3.1 Control Unit Manulhcturer. DMP 3.2 Mass Notification System 3.2.1 System Type: O In-building MNS—combination E3 In-building MNS—stand-alone Other (specify): 3.2.2 System Features: Additional description of system(s): Model number XR-2400F This system does not incorporate an MNS 0 Wide-area MNS 0 Distributed recipient MNS O Combination fire alarm/MNS 0 MNS autonomous control unit 0 Wide-area MNS to regional national alerting interface Local operating console (LOC) 0 Direct recipient MNS (DRMNS) 0 Wide-area MNS to DRMNS interface D Wide-area MNS to high-power speaker array (HPSA) interface [3 In-building; MNS to wide-area MNS interface 0 Other (specify): 3.3 System Documentation An owner's manual, a copy of the manufacturer's instructions a written sequence of operation, and a copy of the numbered record drawings are stored on site. Location: FACP Room 3A System Software This system does not have alterable site-specific software. Operating system (executive) software revision level: Site-specific software revision date: Revision completed by: A copy of the site-specific software is stored on site. Location: 3.5 Off-Premises Signal Transmission 0 This system does not have off-premises transmission. Name of organization receiving alarm signals with phone numbers: Mann: SDA Security Phone: 1800.896.1144 Supervisory: SDA Security Phone: 1400-896-1144 Trouble: SDA Security Phone: 1-800496-1144 Entity to which alarms are retransmitted: SDA Security Phone: 1-800-896-1144 Method of retransmission: Cell Communicator If Chapter 26, specify the means of transmission from the protected premises to the supervising station: If Chapter 27, specify the type of auxiliary alarm system: 0 Local energy 0 Shunt 0 Wired 0 Wireless NFPA 72, Fig. 10.18.2.1.1 (p 2 o 12) Capyright 02009 Netenal Fe PmtedonAwdetim This torn maybe copWfbr1rdftW use otlseirnn for rse. kmayndbecapiadfor....e.U1ads arot.tilbeUor. 4. CIRCUITS AND PATHWAYS 4.1 Signaling Line Pathways 4.1.1 Pathways Class Designations and Survivability Pathways class: B Survivability level: I Quantity: 3 (See NFPA 72, Sections 12.3 and 12.4) 4.1.2 Pathways Utilizing Two or More Media Quantity: 0 Description: 4.1.3 Device Power Pathways 0 No separate power pathways from the signaling line pathway IN Power pathways are separate but of the same pathway classification as the signaling line pathway fl Power pathways are separate and different classification from the signaling line pathway 4.1.4 Isolation Modules Quantity: 0 4.2 Alarm Initiating Device Pathways 4.2.1 Pathways Class Designations and Survivability Pathways class: B Survivability level: (See NFPA 72, Sections 12.3 and 12.4) 4.2.2 Pathways Utilizing Two or More Media Quantity: 0 Description: Quantity. 3 4.2.3 Device Power Pathways 0 No separate power pathways from the Initiating device pathway IM Power pathways are separate but of the same pathway classification as the Initiating device pathway D Power pathways are separate and different classification from the initiating device pathway 4.3 Non-Voice Audible System Pathways 4.3.1 Pathways Class Designations and Survivability Pathways class: B Survivability level: I Quantity: 17 (See NFPA 72, Sections 12.3 and 12.4) 4.3.2 Pathways Utilizing Two or More Media Quantity: 0 Description: 4.3.3 Appliance Power Pathways No separate power pathways from the notification appliance pathway Power pathways are separate but of the same pathway classification as the notification appliance pathway Power pathways arc separate and different classification from the notification appliance pathway NFPA 72, Fig. 10.18.2.1.1 (p.3of12) CopyrghtO2OO9 NaSonel Fire Poteon Amd0m. Tha form maybe copsd for brd]v!ieluse ottn for rueela. ftnuy not b.c edcronmms eele or th.fr ii. S. ALARM INITIATING DEVICES 5.1 Manual Initiating Devices 5.1.1 Manual Fire Alarm Boxes Type and number of devices: Addressable: Other (specify): 5.1.2 Other Alarm Boxes Description: Type and number of devices: Addressable: Other (specify): 5.2 Automatic Initiating Devices 0 This system does not have manual fire alarm boxes. Conventional: I Coded: Transmitter: This system does not have other alarm boxes. Conventionaj: Coded: Transmitter: 5.2.1 Smoke Detectors 0 This system does not have smoke detectors. Type and number of devices: Addressable: Conventional: 5 Other (specify): Type of coverage: 0 Complete area Partial area 0 Nonrequired partial area Other (specify): Type of smoke detector sensing techoologr. 0 Ionization Z Photoelectric 0 Multicriteria 0 Aspirating 0 Beam Other (specify): 5.2.2 Duct Smoke Detectors 0 This system does not have alarm-causing duct smoke detectors. Type and number of devices: Addressable: Conventional: 17 Other (specify): Type of coverage: Type of smoke detector sensing technology: 0 Ionization Photoelectric D Aspirating 0 Beam 5.23 Radiant Energy (Flame) Detectors 3 This system does nothave radiant energy detectors. Type and number of devices: Addressable: Conventional: Other (specify): Type of coverage: 5.2.4 Gas Detectors 0 This system does not have gas detectors. Type of detector(s): Number of devices: Addressable: Conventional: Type of coverage: 5.2.5 Heat Detectors This system does not have heat detectors. Type and number of devices: Addressable: Conventional: Type of coverage: 0 Complete area 0 Partial area 0 Nonrequired partial area D Linear. 0 Spot Type of heat detector sensing technology: 0 Fixed temperature 0 Rate-of-rise 0 Rate compensated NFPA 72, Fig. 10.182.1.1 (p.4of 12) Ccpyttght 02009 NotIonal Fue Pioteotion Meociatlan. Thlsfcnn may be capiedror bldMaI uee other thi forr.ul.. It may not be copIed for coimerced eel. ordaliibid 5. ALARM INITIATING DEVICES (continued) 5.2.6 Addressable Monitoring Modules Number of devices: 8 5.2.7 Waterfiow Alarm Devices Type and number of devices: Addressable: 5.28 Alarm Verification Number of devices subject to alarm verification: 5.2.9 Preslgnal Number of devices subject to presignal: Describe presignailbuctions: 5.2.10 Positive Alarm Sequence (PAS) Describe PM: 52.11 Other Initiating Devices Describe: D This system does not have monitoring modules. 0 This system does not have waterfiow alarm devices. Conventional: 3 Coded: Transmitter Z This system does not incorporate alarm verification. Alarm verification set for seconds This system does not incorporate pre.signat This system does not incorporate PAS. IM This system does not have other Initiating devices. S 6. SUPERVISORY SIGNAL-INITIATING DEVICES 6.1 Sprinkler System Supervisory Devices 0 This system does not have sprinkler supervisory devices. Type and number of devices: Addressable: Conventional: 3 Coded: Transmitter: Other (specify): 6.2 Fire Pump Description and Supervisory Devices IN This system does not have a fire pump. Type fire pump: 13 Electric pump 0 Engine Type and number of devices: Addressable: Conventional: Coded: Transmitter: Other (specify): 6.2.1 Fire Pump Functions Supervised 13 Power 11 Running O Phase reversal D Selector switch not inSato jJEngine or control panel trouble Cl Low fuel Other (specify): 6.3 Duet Smoke Detectors (DSDs) 10 This system does not have DSDs causing supervisory signals. Type and number of devices: Addressable: Conventional: Other (specify): Type of coverage: Type of smoke detector sensing technology: 0 Ionization 0 Photoelectric 0 Aspirating 0 Beam 6A Other Supervisory Devices This system does not have other supervisory devices. Describe: NFPA 72, Fig. 10.182.1.1 (p. 5 of 12) capydgttO2OO9 Netemi Fe P teIonAuodaIii. Thistem maybe copied for irvIOuI use otIurthen?ocreaa It may not be 00pledcommnot.1 Is mdbetiIan. MONITORED SYSTEMS 7.1 Engine-Driven Generator 7.1.1 Generator Functions Supervised 0 Engine or control panel trouble 0 Generator running 0 Other (specify): 7.2 Special Hazard Suppression Systems Description of special hazard system(s): 7.3 Other Monitoring Systems Description of special hazard system(s): ANNUNCIATORS 8.1 Location and Description of Annunciators Location 1: Lobby Location 2: Location 3: I IN This system does not have a generator. 0 Selector switch not in auto 0 Low fuel This system does not monitor special hazard systems. 10 This system does not monitor other systems. 0 This system does not have annunciators. 9. ALARM NOTIFICATION APPLIANCES 9.1 In-Building Fire Emergency Voice Alarm Communication System 0 This system does not have an EVACS. Number of single voice alarm channels: Number of multiple voice alarm channels: Number of speakers: Number of speaker circuits: Location of amplification and sound-processing equipment: Location of paging microphone stations: Location 1: Location 2: Location 3: 9.2 Nonvoice Notification Appliances D This system does not have nonvoice notification appliances. Horns: 48 With visible: 48 Bells: 0 With visible: 0 Chimes: 0 With visible: 0 Visible only 60 Other (describe): 9.3 Notification Appliance Power Extender Panels D This system does not have power extender panels. Quantity: 4 Locations: 1 at Panel. I Upetaim Data Room, 2 Back WIne Data Room NFPA 72, Fig. 10.18.2.1.1 (p.6 of 12) OcpiigMCNatxI Fire Pratedian Amociatoa llisform mwb*ooPWfbrhdvftW= o5Ditan for ressle. Cc ynotbecaped1ccnunvcat sele ardatitMoit MASS NOTIFICATION CONTROLS, APPLIANCES, AND CIRCUITS 0 This system does not have an MNS. 10.1 MNS Local Operating Consoles Location I: Location 2: Location 3: 10.2 High-Power Speaker Arrays Number of I1PSA speaker initiation rcnes Location I: Location 2: Location 3: 10.3 Mass Notification Devices Combination fire alarm/MNS visible appliances: MNS-only visible appliances: Textual signs: Other (describe): Supervision class: 10.3.1 Special Hazard Notification El This system does not have special suppression predischarge notification- 13 MNS systems DO NOT override notification appliances required to provide special suppression predischarge notification. TWO-WAY EMERGENCY COMMUNICATION SYSTEMS 111 Telephone System IN This system does not have a two-way telephone system. Number of telephone jacks installed; Number of warden stations installed: Number of telephone handsets stored on site: Type of telephone system installed. D Electrically powered 0 Sound powered 11.2 Two-Way Radio Communications Enhancement System I] This system does not have a two-way radio communications enhancement system. Percentage of area covered by two-way radio service: Critical areas: % General building areas: Amplification component locations: Inbound signal strength. dBm Outbound signal strength: dBm Donor antenna isolation is: dB above the signal booster gain Radio frequencies covered: Radio system monitor panel location: NFPA 72, Fig. 10.18.2.1.1 (p. 7of12) RLI copydght 02009 NatIonal Fire F, Auooiafia,LThIoftrm Maybe aWled nI use aft thntfarma lifflayrotbecoplaciftowmeidaI aalembdioa TWO-WAY EMERGENCY COMMUNICATION SYSTEMS (continued) 11.3 Area of Refuge (Area of Rescue Assistance) Emergency Communications Systems 0 This system does not have an area of refuge (area of rescue assistance) emergency communications system. Number of stations: Location of central control point Days and hours when central control point is attended Location of alternate control point: Days and hours when alternate control point is attended: 11.4 Elevator Emergency Communications Systems 0 This system does not have an elevator emergency communications system. Number of elevators with stations: Location of central control point Days and hours when central control point is attended: Location of alternate control point Days and hours when alternate control point is attended: 115 Other Two-Way Communication Systems Describe: CONTROL FUNCTIONS This system activates the following control fuctions: Hold-open door releasing devices 0 Smoke management IM HYAC shutdown IN F/S dampers D Door unlocking D Elevator recall 0 Fuel source shutdown 0 Extinguishing agent release Elevator shunt trip C] Mass notification system ovenide of fire slam notification appliances Other (specify): 12.1 Addressable Control Modules Number of devices: Other (specify): 13. SYSTEM POWER 13.1 Control Unit 13.1.1 Primary Power Input voltage of control panel: 120 VAC Overcunent protection: Type: Ckt Bkr Location (of primary supply panel board): In Panel Room Disconnecting means location: 13.1.2 Engine-Driven Generator Location of generator: Location of fuel storage: 0 This system doss not have control modules. Control panel amps: 1.85A Amps: 20 IM This system does not have a generator. Type of fuel: NFPA 72, Fig. 10.18.2.1.1 (p. 8.0? 12) CcpyTI9M6 2009 HaVaid FffePm*danAvsaWkn This m ITy bs CX eCIittLot um a0w1ftr resote. It toy not be cxd for caena eornbuItott 13. SYSTEM POWER (conflnued) 13.1.3 Umnterruptlble Power System 0 This system does not have a UPS. Equipment powered by a UPS system: Location of UPS system Calculated capacity of UPS batteries to drive the system components connected to it- In standby mode (hours): In alarm mode (minutes): 13.1.4 Batteries Location: In Panel Type: Sealed Nominal voltage: I2VDC Amp/hour rating: 14Ah Calculated capacity of batteries to drive the system: In standby mode (hours): 24 In alarm mode (minutes): 5 Batteries are marked with date of manufacture 0 Battery calculations are attached 13.2 In-BuildIng Fire Emergency Voice Alarm Communication System or Mass Notification System This system does not have an EVACS or MNS system. 13.2.1 Primary Power Input voltage of EVACS or MNS panel: Overcurrent protection: Type: Location (of primary supply panel board): Disconnecting means location: 132.2 Engine-DrIven Generator Location of generator. Location of fuel storage: EVACS or MNS panel anipar Amps: 0 This system does not have a generator. Type of fad: 13.2.3 Uninterruptlble Power System D This system does not have a UPS. Equipment powered by a UPS system: Location of UPS system: Calculated capacity of UPS batteries to drive the system components connected to it In standby mode (hours): In alarm mode (minutes): 13.2.4 Batteries Location: Type: Nominal voltage: Amp/hour rating: Calculated capacity of batteries to drive the system: In standby mode (hours): In alarm mode (minutes): 0 Batteries are marked with date of manufacture 0 Battery calculations are attached NFPA 72, Fig. 10.18.2.1.1 (p.90112) copyrIhte2009 NutIcsJ FftPAAecftnAs9odvftL This ftm ny be pisd ICr bIdMI ian if,ieie. ftnuy mt be xpied ?wnmeivI ss dsbtu5at 13. SYSTEM POWER (continued) 13.3 NotIfication Appliance Power Extender Panels 0 This system does not have power extender panels. 13.3.1 Primary Power Input voltage of power rtender panel(s): 120 VAC Power extender panel amps: 2A Overcwreat protection: Type: Ckt Breaker Amps: 20 Location (of primary supply panel board): In S3iflO rOOn as NAC Power Supply Disconnecting means location: 13.3.2 Engine-Driven Generator R This system does not have a generator. Location of generator. Location of fire! storage: . Type of fuel: 13.3.3 Unlnterruptible Power System 0 This system does not have a UPS. Equipment powered by a UPS system: Location of UPS system: Calculated capacity of UPS batteries to drive the system components connected to in In standby mode (hours): In alarm mode (minutes): 13.3.4 Batteries Location: in Panels Type: Sealed Calculated capacity of batteries to drive the system: In standby mode (hours): 24 IN Batteries are marked with date of manutucture Nominal voltage: 12 (24) Amp/hour rating 7 In alarm mode (minutes): 5 0 Battery calculations are attached 14. RECORD OF SYSTEM INSTALLATION Fill out after all Installation Is complete and wiring has been checkedfor opens, shora groundfaults, and improper branching but before conducting operational acceptance tests. This is n: D New system IM Modification to an existing system Permit number: FA120055 The system has been installed in accordance with the following requirements: (Note any or all that apply.) IN NFPA 72, Edition: 2010 IN NFPA 70, National Fiectrical Code, Article 760, Edition:. 2008 Manufacturer's published instructions Other (specify): System deviations from referenced NFPA standards: Signed: Printed name: Date: Organization: Title: Phone: NFPA 72, Fig. 10.182.1.1 (p. 10 of 12) Copyright O2O9 Natlanal Ffre P tmXjiAaaoctatlan. Thl.rTn maybe ccpAdfbrbxjftWuwadwftmfbrraW@L it may trot be cplSd for cammeraI sabortwMAim RECORD OF SYSTEM OPERATIONAL ACCEPTANCE TEST 13 New system All operational features andfrndiong ofthLs system were tested by, or In the presence of; the signer shown below, on the date shown below. and were fow4 to be operatlngproperly in accordance with the requirements for the following; Modifications to an adstin system All newly mothfted operationalfeatures andfunetlone ofthe system were tested by, Orin the presence of; the signer shown below, on the date shown below. and were found to be operating properly In accordance with the requirements ofthefollowing: NFPA 72, Edition: 2010 NFPA 70, National Electrical Code, Article 160, Edition: 2008 IM Manufacturer's published instructions Other (specify): II Individual device testing docmeentation (Inspection and Testing Form (Figure 14.61.4) is attached] Signed: Printed name: Date: Orgntion Title: Phone: CERTIFICATIONS AND APPROVALS 16.1 System Installation Contractor. This system, as specified herein, has been installed and tested according to all NFPA standards cited herein. Printed name: LEE HOPPER Date: 2-28-13 Organization: SDA SECURITY Title: FIELD SUPERVISOR Phone: 619.414-2844 16.2 System Service Contractor: The undersigned has a service contract for this system In effect as of the date shown below. 4 Signed: __ Printed name: LEE HOPPER Organization: SDA SECURITY Title: FIELD SUPERVISOR 16.3 Supervising Station: This system, as specified herein, will be monitored according to all NFPA standards cited herein. Signed: name: LEE HOPPER Organization: SDA SECURITY Title: FIELD SUPERVISOR Date: 2-28-13 Phone: 619-4142644 Date: 2-28-13 Phone: 619414-2644 NFPA 72, Fig. 10.18.2.1.1 (p. 11 of 12) Copight 02009 K.ticn.I Fhe ProtecXnAu.odian, ThTrcnn imybe xpedtuhidMduaI te athere ifarreselo. ft.my flat be oatsd for commethI udiibu5on. It CERTIFICATIONS AND APPROVALS (continued) 16.4 Property or Owner Representative: I accept this system as having been installed and tested to its specifications and all NFPA standards cited herein. Signed: Printed name: Date: Organization: Title: Phone: 163 Atitborlty Having Jurisdiction: I have witnessed a satisfhctozy acceptance test of this system and find it to be installed and operating properly in accordance with its approved plans and speciflcafion with its approved sequence of operatlons and with all NFPA stan cited herein. Signed Printed name: eeP/ L 7(4#iJ Date Z. Z. Z8 15 Organization: Te:tjrfljjtg (I4jjE5#*tL Phone: 7 (.ô q9eds NFPA 72, Fig. 10.182.1.1 (p. 12 of 12) CopticJd92OOB NeftW Fue Pr anMacs5a,t TNsfbrm may be copied lOr indlvIml toe oth.thwi for reeds. Ito ynctb.ccpiedfcrcomm.ral edeordibulico.