HomeMy WebLinkAbout1825 ASTON AVE; ; FPC2020-0047PERMIT REPORT (ity of Carlsbad Print Date: 09/21/2023 Permit No: FPC2020-0047 Job Address: 1825 ASTON AVE, CARLSBAD, CA 92008-7341 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2121201200 Valuation: $0.00 Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Track #: Lot #: Project #: Plan #: Construction Type: Orig. Plan Check #: Plan Check#: Applied: 03/18/2020 Issued: 03/30/2020 Finaled Close Out: 10/06/2020 Final Inspection: INSPECTOR: Maldonado, Adalmira Project Title: Description: REFLEX CORP -NEW FIRE PANEL ALONG WITH CELL TRANSMISSION Applicant: FPContractor: SECURITAS TECHNOLOGY STANLEY SECURITY STANLEY SECURITY SCOTT HAINES 9240 TRADE PL, # STE 300 13034 CREE DR SAN DIEGO, CA 92126-6314 POWAY, CA 92064-3815 (858) 752-1775 (858) 276-9742 FEE AMOUNT FIRE TI Fire Alarm System $620.00 Total Fees: $620.00 Total Payments To Date: $620.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov 5104B Honeywell DSILENT' KNIGHT 5104B Fire Control Communicator The Silent Knight Model 5104B is a six-zone fire control communicator providing digital fire reporting over ordinary telephone lines, eliminating the need for costly leased lines. Its UL 864 and N FPA 72 approved for monitoring local evacuation controls. As a stand-alone unit, it can be used to monitor: Sprinkler systems for waterf low, supervisory, and gate valve tamper conditions. Automatic fire detection systems for structures that are not required to have a fire alarm system but want property protection (e.g. to call the fire department after hours). Monitors dry contact alarms, trouble and supervisory outputs, then transmits a separate code for each. The Model 5104B is fully supervised. Its microprocessor constantly runs programs to monitor AC, standby battery, zone inputs and telephone line connections. If a fault condition is detected, it sounds a local trouble audible and reports the condition to the central station. If one of the telephone lines faults for more than 60 seconds, it will automatically switch to the other to report the failure. The communicator will signal activation, restoration and trouble conditions on any of the six inputs. If an application requires a different input configuration, the individual input styles may be changed by using a Model 7181 Fire Zone Converter Module. The 7181 also allows use of two-wire type smoke detectors, instead of the normal four-wire contact type, for automatic fire detection applications. FEATURES & BENEFITS UL864Listed as an SixfuUy supervised Fuseless overload Reports in SIA and AsingLe, NFPA 72 Central inputs: one Class A protection with most major programmable output Station or Remote input, and five Class B automatic reset communications is provided for alarm Station protected inputs circuitry and fault formats or dialer failed premise unit Downloadable for indicators - Operates on loop start conditions (cannot be FM approved remote programming eliminates the cause phone lines ahead of used for evacuation Can be used as a 60 hours of standby of most field calls. the building PBX purposes).. stand-alone orasa power • Dual phone line system. add-on DACT interface Automatic self tests every 24 hours with report sent to central station 5104B Technical. Specifications Fora complete listing of all PHYSICAL ORDERING INFORMATION compliance approvals and certifications, please visit Dimensions: 12.25"W x 14.5'H x 3.0' D (31.1cm W 5104B: Fire Alarm Communicator. Four-zone www.siLentknight.com. x 36.8 cm H x 7.6cm D) digital communication of fire and trouble. Microsoft, Windows, and Weight: 15 tbs. (6:75 kg) the Windows Logo are Color: Red ACCESSORIES registered trademarks 5230: Remote Annunciator/Programmer ortrademarks of ENVIRONMENTAL 7181: Fire Zone Converter Module Microsoft Corporation. Operating Temperature: 32°F to 120°F (0°C to 7860: Telephone Connecting Cord for RJ31X Jack Honeywell is a registered 49°C) (2 required) trademarks of Honeywell Humidity: 10 to 93% relative humidity (non- 6712: 12 volt, 74H rechargeable battery International. Inc condensing) I This document is not COMMUNICATION FORMATS: intended to be used for ELECTRICAL: SIA, SK 3/1, Sescoa 3/1, Contact ID, SK4/2, installation purposes. We Add-on Applications - UL Listed Radionics BFSK try to keep our product Input: 120VAC 60Hz 40 watts information up-to AGENCY LISTINGS AND APPROVALS date and accurate. We CURRENT: cannot cover all specific UL Listed - U L864/N FPA 72 Central and applications or anticipate Standby: 50mA all requirements. Ali Alarm: 135mA Remote Supervising specifications are subject to change without notice. STAND ALONE APPLICATIONS • Station Fire Alarm System Service . For Technical Support, Input: 120VAC 60Hz 40 watts • FM Approved call 800-446-6444 Standby: 12V 7 amp hour rechargeable battery CSFM Approved 5230 Remote Annunciator: (three maximum per system) 114- MEA 1 Load: 60mA standby, 120mA alarm INDICATOR LIGHTS (LEDS) Power On: (Green) Trouble Silenced: (Yellow) Until Trouble is Cleared/Flashing: Supervisory Dialer Failure: (Yellow) Telephone Line Fault: (2 Red) Inside Cabinet at Li and L2 Inputs TELEPHONE REQUIREMENTS FCC Registration #: 4C698R-17462-AL-E RINGER EQUIVALENCE: 0.OB Type of Jack: RJ31X (2 required) I For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywell Silent Knight 12 Clintonville Road , Honeywell Northford, CT 06472 r SILENT' Doc 3503491 Rev F 105/08 U KNIGHT 800-328-0103 @2018 Honeywell International Inc. HWF2= M Sr.Rlr.S LIE / IP Single or Dual Path Commercial Fire Communicators LTE and IP connection tested everyday Three selectable reporting paths: LTE cellular only, IP only, or IP Primary with LTE cellular backup Requires no change to the existing FACP configuration Connects directly to the primary and secondary telephone ports of a DACT Plan choices range from 5 minute, 60 minute, 6 hour, and 24 hour supervision intervals Operates over the following communication protocols: LIE, HSPA+(4G) HSPA (3G) Works over any type of customer provided Ethernet 10/100 based network connection (LAN or WAN), DSL model or cable modem Data transmits over standard Contact ID protocol but is secured with the industry's advanced encryption standard (AES 256 bit) Supports both dynamic (DHCP) or public and private Static IP addressing Reliable connection: IP and cellular connection tested everyday Built-in, standalone power supply module. Onboard charging circuit design accommodates battery backup. Includes primary power and battery supervision Diagnostic LEDs indicate signal strength and status Choice of LTE provider services QOS: Quality of Service diagnostics via AlarmNet conveys vital communicator information including signal strength, message path used, and when the message was received 7720P Handheld programmer for easy setup Honeywell The HWF2-COM Series LTE / IP fire communicators are single or dual path commercial fire alarm communicators that offer Contact ID reporting with any FACP (fire alarm control panel) with a built-in dialer. Models include: HWF2A-COM (AT&T LTE& IP) HWF2V-COM (Verizon LTE & IP) Both models connect directly to the primary or secondary communication ports of a fire panel's digital alarm communicator transmitter (DACT). Three selectable reporting paths include: LTE cellular only, I P only, or I P primary with LIE cellular backup. All signals from the HWF2-COM Series are delivered to the AlarmNet® network control center which routes highly encrypted, cybersecured Ethernet data packets via a customer-provided Internet connection or LTE cellular network to the appropriate central station. The AlarmNet® network control center is fully redundant and monitored 24/7. Installation and programming are easy using the handheld 7720P Programming too[. FEATURES AND BENEFITS The HWF2-COM LTE / IP fire communicators operate over the most modern and common cellular networks including LTE, 4G and3G. They connect to any customer provided Ethernet 10/100 base network connection (LAN or WAN), DSL or cable modem. Selectable reporting path feature allows the radios to be configured for a single or dual path, while providing appropriate supervision intervals based on NFPA 72 requirements. Selectable paths and supervision timing intervals include: 2010 Celt I Single path, cellular 15 Minutes 20101P Single path, IP 5 Minutes 2010 IP & Cell Dual path, IP and cellular 24 Hours 2013 Cell Single path, cellular 60 Minutes 2013 IP SingLe path, IP 60 Minutes 2013 IP & Cell I Dual path, IP and cellular 1 6 Hours OPERATION When an event occurs, the FACP goes off-hook to dial the central station. The HWF2-COM Series dialer capture module detects the off-hook condition and provides the fire panelwith a dialtone. When the fire panel detects the dial tone, it begins dialing the central station. After the dialing is completed, the dialer capture module returns a signal to the fire panel. The fire panel then sends the Contact ID reports to the dialer capture module, which in turn sends a signal after the report is successfully received from the fire panel. The dialer capture nodule sends the Contact ID reports to the HWF2- COM Series communications module. When allthe reports are sent, the fire panel goes on-hook. The HWF2-COM Series communications module then transmits the messages to the central station either over the LIE network or the Internet (depending on configuration). FIRE COMMUNICATOR I PANEL CAPABILITY The HWF2-COM Series is compatible with fire alarm control panels that use the Contact ID communications format as described in the SIA DC-05 standard. EASY TO PROGRAM The HWF2-COM communicator can be pre-programmed using the 7720P programmer to enter all central station information. This is saved to the HWF2-COM communicator panel memory. When the HWF2-COM is installed at the site and connected to the Internet! Intranet, it registers with the AlarmNet Receiver. For most installations, the only required parameters are: Primary City ID (two digits), obtained from your monitoring station Primary Central Station ID (two digits), obtained from your monitoring station Page 2 of 3— DH-62010:13 • 6/27/2019 Primary Subscriber ID (four digits), obtained from your monitoring station Communication Module MAC ID, and MAC CRC number located on the outside of the box and inside of the module All parameters are assigned by the monitoring station. ALARMNET AlarmNet communications technology provides a highly reliable alternative for the transmission of alarm signals. The network provides extensive coverage in the United States and Canada. The AlarmNet Network Control Center processes signals from powerful servers in multiple locations equipped with 24/7 infrastructure support. Redundant hardware servers, real-time backup databases, and generators with battery backup at all locations ensure continuity of service. Signals from AlarmNet are transmitted to central station receivers using multiple communication paths consisting of the Internet, LTE radio network, ortoltfree plain old telephone service (POTS). Visit AlarmNet.com to learn more. INSTALLATION REQUIREMENTS, UL COMPLIANCE To meet UL864/NFPA requirements, ensure the following: HWF2-COM Series must be installed in accordancewith the National Fire Protection Association (NFPA) standards 70 and 72 HWF2-COM Series must be mounted in the same room and within 20 feet of the fire panel. HWF2-COM Series and all equipment used for the IP connection (e.g., router, hub, modem, etc) must be UL-listed, powered from an unswitched branch circuit, and be provided with appropriate standby power. HWF2-COM Series must use the 7AH battery (not included) to provide 24 hour backup capability HWF2-COM SERIES TECHNICAL SPECIFICATIONS ELECTRICAL Transformer: Primary: I20VAC, 60Hz, 0.5A Secondary: 18VDC, 50VA Battery: One 12 V 7.0 AH lead-acid battery: (not supplied) Battery charging current: 1 Amp maximum Battery discharge current: Standby 230mA, Active 950mA CABINET SPECIFICATIONS Dimensions: 14.875'H x 12.75w W x 3.0' 0 (37.8cm H x 32.4cm W 7.6cm D) Color: Red SHIPPING DIMENSIONS Weight: 5.3 lbs (6.94k9) Dimensions: 15.625' H x 13.79W x 9.25' D (39.7cm H x 34.9cm W x 23.9cm D) TEMPERATURE AND HUMIDITY RANGES This system meets NFPA requirements for operation at 0- 490C/32-1201F and at a relative humidity 93%+- 2% RH (non- condensing at 32°C +- 20C(901F +-30F). However the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15- 270C/60-800F. PRODUCT LINE INFORMATION HWF2V-COM:. LIE Digital Cellular Fire Alarm Communicator and Internet Panel, Verizon LTE /IP HWF2A-COM: LTE Digital Cellular Fire Alarm Communicator and Internet Panel, AT&T LTE /IP Both models include: Red cabinet with key and Lock Wall outlet box Dialer capture module LTE communications module Antenna and mounting adapter PowerBoosti power supply LED display board Transformer Manual and required screws Cables, etc. ANTENNA AND EXTERNAL HARDWARE CELL-ANT3DB: 3dBA gain antenna WA7626-CA: SMA to N adapter cable 7626-50HC: 50 ft. antenna cable, low loss Note: The WA7626-CA adapter cable and 7626-50HC antenna cable are only required when installing the CELL-ANT3DB antenna remotely. OTHER ACCESSORIES 7720P: HWF2V-COM, HWF2A-COM and IPGSM-4G handheld programmer HPTCOVER: Plug-in transformer box for HWF2V-COM, HWF2A-COM, and IPGSM- 4G communicators BAT-1270: Battery 12 Volts, 7AH, sealed AGENCY LISTINGS AND APPROVALS The listings and approvals below apply to the HWF2-COM Series communicators. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult the factory for latest listings. UL Listed: S789 CSFM: 7300-1645:0511 FDNY: Approved Honeywell Power Products 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.honeyweLlpower.com DH-62010 I B 106/19 @2019 Honeywell International Inc. THE FUTURE Is WHAT WE MAKE IT Honeywell