Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
4970 AVENIDA ENCINAS; ; FS150019
9/21/23,2:57 PM FS150019 Permit Data City of Carlsbad Fixed Systems Permit Permit No: FS150019 4970 AVEN IDA Job Address: Status: ISSUED ENCINAS Permit Type: FIXSYS Applied 10/27/2015 Parcel No: 2100110400 Approved: 10/27/2015 Lot #: 0 Reference No.: Issued: 10/27/2015 PC #: Inspector: Project Title: WEST INN AND SUITES INSTALLATION OF KIDDE FM-200 FIRE SUPPRESSION SYSTEM IN SERVER EQUIPMENT ROOM. INSTALLATION OF AGENT STORAGE CYLINDER, DISCHARGE PIPING AND DISCHARGE NOZZLE. INSTALLATION OF SMOKE DETECTION. INSTALLATION OF MANUAL RELEASE, ABLORT SWITCH, MAINTENANCE BYPASS LOCKOUT SWITCH, AND AGENT RELEASE SOLENOID. INTEGRATE WITH HVAC SYSTEM TO SHUT DOWN AIR AND/OR CLOSE DAMPERS. INTEGRATE WITH BUILDING FIRE ALARM SYSTEM FOR PROPER MONITORING. FULL FUNCTIONAL TESTING SYSTEM CERTIFICATION TAGS. Owner: WEST REAL ESTATE L L C Applicant: SCHMIDT FIRE PROTECTION CO INC 4760 MURPHY CANYON RD SAN DIEGO, CA 92123 858-279-6122 5796 ARMADA DR #300 CARLSBAD CA Fees ($) Add'l Fees ($) Total ($) Balance ($) about:blank 1/2 9/21/23, 2:57 PM FS150019 Permit Data 306 0 306 0 about:blank 2/2 A '6chmidt Fire PrutEctkrn Cu, Inc. in 4760 MURPHY CANYON RD • SAN DIEGO, CA 92123 • (858) 279-6122 • FAx (858) 279-3583 WEST INN & SUITES 4970 Avenida Encinas Carlsbad, CA 92008 Server Room, Clean Agent, FM-200 Fire System SH-1076 SUBMITTAL PACKAGE Design by: Date Gordon E. Swope SET October, 19 2015 (NICET Level-IV #078621) APPOtD AS SUBMITTED t ati /,, zz. f2 C(RLSbAD FIRE DEPARTMENT fKidde Fire Systems For Training Only Not To be used as a Listed Design. Software Provided for Training Purpposes Only ECS Series - K103.03 UL: EX4674 Project: WEST INN SERVER ROOM File Name: WEST INN.FLC Consolidated Report Customer Information Company Name: WEST DEVELOPMENT Address: 5796 ARMADA DRIVE, SUITE 300 CARLSBAD, CA 92008 Phone: 760_602-5842 Contact: ANTHONY WINTER Title: Project Data Project Name: WEST INN SERVER ROOM Designer: G.E.SWOPE SET (NICET #78621 Number: Account: Location: Description: WEST INN & SUITES SERVER ROOM Page: 1 of 6 Calculation Date/Time: Friday, October 09, 2015, 11:24:24 Copyright (C) Hughes Associates, Inc. Licensed to: Kidde-Fenwal 'Kidde Fire Systems Consolidated Report Enclosure Information Elevation: 0 ft (relative to sea level) Atmospheric Correction Factor: I Enclosure Number: I Name: SERVER ROOM Enclosure Temperature... Minimum: 70 F Maximum: 70 F Maximum Concentration: 7.020% Design Concentration... Adjusted: 7.020% Minimum: 7.000% Minimum Agent Required: 38.9 lbs Width: 9.5 ft Length: 12.0 ft Height: 10.0 ft Volume: 1140.0 cubic ft Non-permeable: 0.0 cubic ft Total Volume: 1140.0 cubic ft Adjusted Agent Required: 39.0 lbs Number of Nozzles: I Page: 2 of 6 Calculation Date/Time: Friday, October 09, 2015,11:24:24 Copyright (C) Hughes Associates, Inc. Licensed to: Kidde-Fenwal KiddeFirèSystems Consolidated Report Agent Information Agent: FM-200 I Propellant N2 (FM-200 is a Trademark of Great Lakes Chemical Corp.) Adjusted Agent Required: 39.0 lbs Container Name: 40 lb Cylinder Container Part Number: 90-100040-001 Number of Main Containers: I Number of Reserve Containers: 0 Manifold: No Manifold Pipe Take Off Direction: Horizontal Agent Per Container 39.0 lbs Fill Density: 68.2 lbs / cubic ft Container Empty Weight: 38.0 lbs Weight, All Containers + Agent: 77.0 lbs Floor Area Per Container: 0.44 square ft Floor Loading Per Container: 175 lbs / square ft Pipe Network Part I - Pipe Pipe Description Start End Type Diameter Length Elevation Main Cyl. X 0 1 1-1/2 in - 1.79 ft - 1.79 ft Adapter 1 2 - - 1-1/2 in - - 0.22 ft 0.00 ft Pipe 2 3 40T 3/4 in 0.25 ft 0.00 ft Pipe - 3 4 40T 3/4 in 0.25 ft 0.00 ft -- - -- Pipe 4 5 - 40T - 3/4 in 0.16 ft 0.00 ft Pipe 5 6 40T 3/4 in 7.25 ft 7.25 ft -- - - Pipe 6 7 40T 3/4 in 4.50 ft 0.00 ft Pipe/El-NI 7 8 40T . 3/4 in 0.25 ft -0.25 ft Part 2 - Equivalent Length Start End 90 45 Thru Side Union Other Added Total Page: 3 of 6 Calculation Date/Time: Friday, October 09, 2015, 11:24:24 Copyright (c) Hughes Associates, Inc. Licensed to: Kidde-Fenwal Kidde Fire Sy5tems Consolidated Report Part 2 - Equivalent Length Start End 90 45 Thru Side Union Other Added Total 0 1 0 0 0 0 0 0.00 ft 50.0 ft I 2 0 0 0 0 0 1-1/2inVOA 0.00 ft 11.8 ft 2 3 0 0 0 0 0 0.00 ft 0.3 ft 3 4 0 0 0 0 0 0.00 ft 0.3 ft 4 5 5 6 6 7 0 0 1 0 1 0 0 0 0 0 0 0 0 0 0 0.00 ft 0.00 ft - 0.00 ft 0.2 ft 9.5 ft 6.7 ft 7 8 Part 3 - Nozzles Start End 1 0 0 Flow Name 0 0 Size Type 0.00 ft Nozzle Area 2.5 ft 0 1 39.0 lbs 1 2 2 3 39.0 lbs 39.0 lbs; 3 4 39.0 lbs 4 5 39.0 lbs 5 6 39.0 lbs 6 7 39.0 lbs 7 8 39.0 lbs El-NI 3/4 in 180° 0.2177 square in Parts Information Total Agent Required: 39.0 lbs Container Name: 40 lb Cylinder (Part: 90-100040-001) Number Of Containers: I Nozzle Type Nozzle Area Part Number El-NI 1800 0.2177 square in 90-194014-182 Pipe: Type Diameter Length 40T 3/4 in 12.66 ft 'Other' Items: Page: 4 of 6 Calculation Date/Time: Friday, October 09, 2015, 11:24:24 Copyright (C) Hughes Associates, Inc. Licensed to: Kidde-Fenwal it Kidde Fire Systems Consolidated Report I - 1-1/2 in. Valve Outlet Adapter (Part: 283904) List of 90 degree elbows: 3 - 3/4 in System Acceptance System Discharge Time: 10.0 seconds Percent Agent In Pipe: 15.2% Percent Agent Before First Tee: 0.0% Enclosure Number: I Enclosure Name: SERVER ROOM Minimum Design Concentration: 7.000% Adjusted Design Concentration: 7.020% Predicted Concentration: 7.020% Maximum Expected Agent Concentration: 7.020% (At 70 F) Minimum Adjusted Predicted Nozzle Agent Agent Agent Pressure Nozzle Required Required Delivered (Average) El-NI 38.9 lbs 39.0 lbs 39.0 lbs 137 psig Page: 5 of 6 Calculation Date/Time: Friday, October 09, 2015, 11:24:24 Copyright (C) Hughes Associates, Inc. Licensed to: Kidde-Fenwal 'KIddeFiresystems Consolidated Report Standard Isometric View Page: 6 of 6 Calculation Date/Time: Friday, October 09, 2015, 11:24:24 Copyright (C) Hughes Associates, Inc. Licensed to: Kidde-Fenwal The MSDS format adheres to the standards and regulatory requirements of the United States and may not meet regulatory requirements in other countries. DuPont Page 1 Material Safety Data Sheet ---------------------------------------------------------------------- FM-200 6402FR Revised 28-FEB-2008 ---------------------------------------------------------------------- ---------------------------------------------------------------------- CHEMICAL PRODUCT/COMPANY IDENTIFICATION ---------------------------------------------------------------------- Material Identification F74-200 is a registered trademark of DuPont. CAS Number : 431-89-0 Formula : CF3 CHF CF3 Molecular Weight : 170.03 CAS Name : Propane, 1,1,1,2,3,3,3-Heptafluoro- Tradenames and Synonyms FM2 00 FE-227 2 -Hydroperfluoropropane Propane, 1,1,1,2,3,3,3-Heptafluoro- HFC-227eaHP 2 -Hydroheptafluoropropane Heptafluoropropane 2 -H-heptafluoropropane 1,1,1,2,3,3, 3-Heptafluoropropane R-227 R227 HFC-227ea Company Identification MANUFACTURER/DISTRIBUTOR DuPont Fluoroproducts 1007 Market Street Wilmington, DE 19898 PHONE NUMBERS Product Information : 1-800-441-7515 (outside the U.S. 302-774-1000) Transport Emergency : CHEMTREC 1-800-424-9300(outslde U.S. 703-527-3887) Medical Emergency : 1-800-441-3637 (outside the U.S. 302-774-1000) ---------------------------------------------------------------------- COMPOSITION/INFORMATION ON INGREDIENTS ---------------------------------------------------------------------- Components Material CAS Number 1,1,1,2,3,3, 3-Heptafluoropropane 431-89-0 99.95 6402FR DuPont Page 2 Material Safety Data Sheet ---------------------------------------------------------------------- HAZARDS IDENTIFICATION ---------------------------------------------------------------------- Potential Health Effects Based on animal data, overexposure to FM-200 by inhalation may cause suffocation, if air is displaced by vapors, and irregular heart beat with a strange sensation in the chest, "heart thumping," apprehension, lightheadedness, feeling of fainting, dizziness, weakness, sometimes progressing to loss of consciousness and death. FM-200 may cause frostbite if liquid or escaping vapor contacts the skin. FM-200 may cause "frostbite-like" effects if the liquid or escaping vapors contact the eyes. In one study, human volunteers were selected to inhale FM-200 at a concentration of 6000 ppm but the study was terminated due to a rise in pulse rate that was believed to be unrelated to the chemical. In a subsequent study with human volunteers inhaling concentrations up to 8000 ppm no clinically significant effects were observed for any of the measured laboratory parameters. Individuals with preexisting diseases of the cardiovascular system or nervous system may have increased susceptibility from excessive exposures. Carcinogenicity Information None of the components present in this material at concentrations equal to or greater than 0.1% are listed by XARC, NTP, OSHA or ACGIH as a carcinogen. ---------------------------------------------------------------------- FIRST AID MEASURES ---------------------------------------------------------------------- First Aid INHALATION If inhaled, imaediately remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Call a physician. SKIN CONTACT Treat for frostbite if necessary by gently warming affected area. EYE CONTACT In case of contact, imeediately flush eyes with plenty of water for at least 15 minutes. Call a physician. 6402FR DuPont Page 3 Material Safety Data Sheet (FIRST AID MEASURES - Continued) INGESTION Ingestion is not considered a potential route of exposure. ---------------------------------------------------------------------- FIRE FIGHTING MEASURES ---------------------------------------------------------------------- Flaimuable Properties 1,1,1,2,3,3, 3-Heptafluoropropane is not flammable, however in the presence of a flame or ignition source it may decompose to form toxic hydrogen fluoride or carbonyl fluoride. Mon-flammable. Extinguishing Media Use media appropriate for surrounding material. Fire Fighting Instructions Self-contained breathing apparatus (SCHA) may be required if cylinders rupture or release under fire conditions. Keep cylinders cool with water spray applied from a safe distance. --------------------------------------------------------- ACCIDENTAL RELEASE MEASURES ---------------------------------------------------------- Safeguards (Personnel) NOTE: Review FIRE FIGHTING MEASURES and HANDLING (PERSONNEL) sections before proceeding with clean-up. Use appropriate PERSONAL PROTECTIVE EQUIPMENT during clean-up. Evacuate personnel, thoroughly ventilate area, use self-contained breathing apparatus. Keep upwind of leak - evacuate until gas has dispersed. Initial Containment Use forced ventilation to disperse vapors. 6402FR DuPont Page 4 Material Safety Data Sheet ---------------------------------------------------------------------- HANDLING AND STORAGE ---------------------------------------------------------------------- Handling (Personnel) Do not breathe gas. Avoid contact with eyes, skin, or clothing. Wash thoroughly after handling. Wash clothing after use. Storage Store in a clean, dry place. Store below 52 C (126 F). ---------------------------------------------------------------------- EXPOSURE CONTROLS/PERSONAL PROTECTION ---------------------------------------------------------------------- &igineering Controls Use only with adequate ventilation. Keep container tightly closed. Personal Protective Equipment EYE/FACE PROTECTION Wear safety glasses or coverall chemical splash goggles. RESPIRATORS Wear NIOSH approved respiratory protection, as appropriate. PROTECTIVE CLOTHING Where there is potential for skin contact have available and wear as appropriate impervious gloves, apron, pants, and jacket. Exposure Guidelines Exposure Limits FM-200 AEL * (DuPont) : 1000 ppm, 8 & 12 Hr. TWA * AEL is DuPont's Acceptable Exposure Limit. Where governmentally imposed occupational exposure limits which are lower than the AEL are in effect, such limits shall take precedence. ---------------------------------------------------------------------- PHYSICAL AND CHEMICAL PROPERTIES ---------------------------------------------------------------------- Physical Data Boiling Point : -16.4 C (2.5 F) Melting Point : -131 C (-204 F) Vapor Pressure : 65.7 psia @ 25 C (77 F) (453.3 kPa) Liquid Density : 1.386 g/cm3 @ 25 C (77 F) (86.53 lb/ft3) Critical temperature : 101.6 C (214.9 F) Critical pressure : 424.7 psia (2930 kPa) Odor : None. 6402FR DuPont Page 5 Material Safety Data Sheet (PHYSICAL AND CHEMICAL PROPERTIES - Continued) Form : Liquified Gas ---------------------------------------------------------------- STABILITY AND REACTIVITY ---------------------------------------------------------------- Chemical Stability Stable at normal temperatures and storage conditions. Avoid sources of heat or open flame. Incompatibility with Other Materials Incompatible with strong reducing agents such as alkali metals (e.g., sodium, potassium), alkali-earth metals (e.g., magnesium, calcium), and powdered aluminum or zinc. Decomposition Decomposes by reaction with high temperature (open flames, glowing metal surfaces, etc.) forming hydrofluoric acid, carbonyl fluorides, carbon monoxide and carbon dioxide. Polymerization Polymerization will not occur. ---------------------------------------------------------------------- TOXICOLOGICAL INFORMATION ---------------------------------------------------------------------- Animal Data FM-200: Inhalation 4 hour LCSO: > 788,698 ppm in rats Repeated exposure of rats by inhalation for 4 weeks at concentrations up to 50,000 ppm revealed no toxicologically significants effects. The NOEL for this study was 50,000 on. A 90-day inhalation study in rats did not find any exposure related effects at 105,000 ppm. The NOEL for this study was 105,000 ppm. Cardiac sensitization, a potentially fatal disturbance of heart rhythm associated with a heightened sensitivity to the action of epinephrine, occurred in dogs at 105,000 ppm. The NOAEL for cardiac sensitization was 90,000 ppm. In a different study to evaluate cardiac sensitization in dogs, concentrations of 90,000, 105,000, and 140,000 on caused a dose-related increase in incidence and severity; at 90,000 ppm efffects were minimal or mild in nature. Inhalation studies in rabbits and rats do not suggest developmental toxicity at concentrations up to 6402FR DuPont Page 6 Material Safety Data Sheet (TOXICOLOGICAL INFORMATION - Continued) 105,000 ppm. Teats have shown that FM-200 does not cause genetic damage in bacterial or mammalian cell cultures. Tests in animals for carcinogenicity or reproductive toxicity have not been conducted. ---------------------------------------------------------------------- DISPOSAL CONSIDERATIONS ---------------------------------------------------------------------- Waste Disposal Treatment, storage, transportation, and disposal must be in accordance with applicable Federal, State/Provincial, and Local regulations. Incinerate material in accordance with Federal, State/Provincial and Local requirements. ---------------------------------------------------------------------- TRANSPORTATION INFORMATION ---------------------------------------------------------------------- Shipping Information DOT Proper Shipping Name Hazard Class I.D. No. (UN/NA) DOT Label(s) Heptafluoropropane : 2.2 : UN 3296 Nonflnhle Gas ---------------------------------------------------------------------- REGULATORY INFORMATION ---------------------------------------------------------------------- U.S. Federal Regulations TSCA Inventory Status : Listed. TITLE III HAZARD CLASSIFICATIONS SECTIONS 311, 312 Acute : Yes Chronic No Fire : No Reactivity : No Pressure : No ---------------------------------------------------------------------- OTHER INFORMATION ---------------------------------------------------------------------- NFPA, NPCA-HMIS NFPA Rating Health : 1 Flammability : 0 Reactivity : 1 NPCA-HMIS Rating Health : 1 Flammability : 0 6402FR DuPont Page 7 Material Safety Data Sheet (Continued) Reactivity : 0 Personal Protection rating to be supplied by user depending on use conditions. The data in this Material Safety Data Sheet relates only to the specific material designated herein and does not relate to use in combination with any other material or in any process. Responsibility for MSDS MSDS Coordinator > : DuPont Fluoroproducts Address : Wilmington, DE 19898 Telephone : (800) 441-7515 This information is based upon technical information believed to be reliable. It is subject to revision as additional knowledge and experience is gained. End of MSDS Part Number Cylinder Size Dimensions (inches) A B C 90-100010-001 10 lb. 7.07 13.34 17.30 90-100020-001 20 1b. 7.07 21.01 24.97 90-100040-001 40 lb. 9.00 22.80 26.76 90-100070-001 70 lb. 9.00 34.87 38.83 MATERIALS Valve Body: Brass Cylinder: Steel, Painted Red COMPATIBILITY Series For Use With Kidde ECS HFC-227ea X Kidde ECS Fire Suppression System Component Description Cylinder and Valve Assemblies 10 lb. (4.5 kg) to 70 lb. (31.7 kg) Capacity, Vertical Mount Only DIM. flA4flh1flh1Vfl Añ4 Kidde Fire Systems Effective: June 2014 K-90-2010 Rev BA FEATURES For Use with UL Listed, ULC Listed and FM Approved Systems • RoHS Complaint See Kidde USCG Approved Manual for USCG Approval ORDERING INFORMATION Notes: The safety cap must be installed on the valve outlet at all times, except when the cylinders are connected to the system piping, or being filled. The safety cap must not be removed from its chain. See K-90-2070 for additional information. Cylinders are vertical mount only. This literature is provided fOr informational purposes only. KIDDE- FENWAL INC. assumes no responsibility for the product's suitability for a particular application. The product must be properly applied to work correctly. If you need more information on this product, or if you have a particular problem or question, contact KIDDE-FENWAL, Inc. 02014 Kidde-Fenwal, Inc. Kidde is a registered trademark of Kidde-Fenwal Inc. All other trademarks are the property of their respective owners. Kidde Fire Systems 400 Main Street Ashland, MA 01721 Ph: 508.881.2000 Fax: 508.881.8920 www.kiddefiresystems.com Kidde ECS Fire Suppression System Component Description Cylinder Data fKidde Fire Systems Effective: June 2014 K-90-2070 FEATURES For Use with UL Listed, ULC Listed and FM Approved Systems • RoHS Compliant MODULAR SYSTEMS CYLINDER DATA Part Number Fill Range Empty Weight Gross Weight With LLI Height Diameter Volume lb. kg lb. kg Mm. Fill Max. Fill -7- in. - cm. - in. - cm. ft.3 m3 90-100010-001 6to10 3t05 25 II 31 14 35 16 No 17.3 44 7.07 18 0.167 0.0047 90-100020-001 11to20 5to9 31 14 42 19 51 23 No 24.97 64 7.07 18 0.286 0.0081 90-100040-001 23t040 10to18 38 17 61 27 78 35 No 26.76 64 9 23 0.572 0.0162 90-100070-001 41t070 19to32 52 24 94 43 123 56 No 38.83 99 9 23 1 0.0283 90-100121-001 71 to 125 32t057 98 45 169 77 223 101 Yes 35.93 92 j12.75 33 1.788 0.0506 90-100125-001 71 to 125 32t057 98 45 169 77 223 101 No 35.93 92 12.75 33 1.788 0.0506 90-100200-001 126 to 200 56t091 139 63 265 120 339 154 No 50.35 128 13.6 35 2.859 0.081 90-100201-001 126t0200 57t091 141 64 267 121 341 155 Yes 50.35 128 13.6 35 2.859 0.081 90-100200-101 126t0200 57t091 133 60 259 118 333 151 No 52.75 134 12.75 33 2.859 0.081 90-100201-101 126t0 200 57t091 133 60 259 118 333 151 IYes 52.75 134 12.75 33 12.859 0.081 90-100350-001 201t0350 91 to 159 201 91 406 182 555 250 No 58.36 149 16 41 5 0.1416 90-100351-001 201 to 350 91 to 159 203 92 408 183 557 251 Yes 58.36 159 16 41 5 0.1416 90-100600-001 351to500 159t0227 335 152 686 312 835 380 No 56.72145 22 56 8.572 0.2427 90-100601-001 351t0500 159t0227 337 153 16881313 837 380 Yes56.72 145 22 56 8.572 0.2427 Note: Modular balanced systems have a fill density range of 40 lbicu.ft. to 58.3 lb./cuit. ENGINEERED SYSTEMS CYLINDER DATA Part Number Fill Range Weight EmptyGross Weight With LLl Height Diameter Volume lb. kg lb. kg Mm. Fill Max. Fill in. cm. in. - cm. ft.3 m3 90-100010-001 5to10 3t05 25 11 30 14 35 16 No 17.3 44 7.07 18 0.167 0.0047 90-100020-001 9t020 4to9 31 14 40 18 51 23 No 24.97 64 7.07 18 0.286 0.0081 90-100040-001 17t040 8t018 38 17 55 25 78 35 No 26.76 68 9 23 0.572 0.0162 90-100070-001 30 to 70 14 to 32 52 24 82 38 123 56 No 38.83 99 9 23 1 0.0283 90-100121-001 54t0 125 25t057 98 45 152 69 223 101 Yes 35.931 92 12.75 33 1.788 0.0506. 90-100125-001 54t0 125 25t057 98 45 152 69 223 101 No 35.93 92 12.75 33 1.788 0.0506 90-100200-001 86t0 200 39t091 139 63 225 102 341 154 No 50.35 128 13.6 35 2.859 0.081 90-100201-001 86t0 200 39t091 141 64 227 103 343 155 Yes 50.35 128 13.6 35 2.859 0.081 90-100200-101 86t0 200 39t091 133 60 219 100 333 151 No 52.75 134 12.75 33 2.859 0.081 90-100201-101 86 to 200 39t091 133 60 219100 333 151 Yes 52.75 134 12.75 33 2.859 0.081 90-100350-001 150t0 350 68t0 159 201 91 351 159 555 250 No 58.36 149 16 41 5 0.1416 90-100351-001 150t0 350 68t0 159 203 92 341 160 557 251 Yes 58.36 149 16 41 5 0.1416 90-100600-001 258t0600 114t0272 335 152 593270 935 425 No 56.72 145 22 56 8.572 0.2427 90-100601-001 258to600 114to272 337 153 595270 937 426 Yes 56.72 145 22 56 8.572 0.2427 90-100600-100 258t0600 117to272j 362 165 620281 962 437 No 58 147 22 56 8.68 0.246 90-100601-100 258t0600 117t0272 362 165 620281 962 437 Yes 58 147 22 56 8.68 0.246 90-100900-0011390 to 900 178t0408 505 230 895407 1405 639 No 70 178 24 61 13 0.368 -0011390 to 900 178t0408 505 1230 18951407 1405 639 Yes 70 1781 24 61 13 0.368 Note: Engineered systems have a fill density range of 30 lbicu.ft. to 70 lbicu.ft. COMPATIBILITY Series For Use With Kdde ECS HFC-227ea X Kidde is registered trademark of Kidde-Fenwal Inc. All other trademarks are the property of their respective owners. This literature is provided for informational purposes only. KIDDE-FENWAL, INC. assumes no responsibility for the products suitability for a particular application. The product must be properly applied to work correctly.lf you need more information on this product, or if you have a particular problem or question, contact KIDDE-FENWAL, Inc. V, Kidde Fire Systems K-90-2070 Rev BA @2014 Kidde-Fenwal, inc. Kidde Fire Systems 400 Main Street Ashland, MA 01721 Ph: 508.881.2000 Fax: 508.881.8920 www.kiddefiresystams.com Kidde ECS Fire Suppression System Component Description Cylinder Mounting Straps Kidde Fire Systems Effective: June 2014 K-90-8130 Rev BA FEATURES For Use with UL Listed, ULC Listed and FM Approved Systems • RoHS Compliant B -j F-.- C - 1 (HOLE SIZE) I I _!?. PART NO. SIZE CYL.O.D. A B C D E F In. mm In. mm In. mm In. mm in. mm In. mm In. mm WK-283945-000 10,20 7.07 1.80 6.48 165 9.62 244 8.62 219 1.00 25 2.78 71 .437 11.1 WK-283934-000 40,70 9.00 229 8.16 207 11.69 297 10.69 272 1.00 25 3.50 89 .437 11.1 292971 200 pre-3198 13.60 345 13.09 332 17.06 433 15.44 392 1.75 44 6.06 154 .625 15.9 06-235317-001 125,200 12.75 324 12.93 329 16.18 411 14.56 370 1.75 44 5.59 142 .625 15.9 WK-281866-000 350 16.00 406 15.5 394 19.5 495 17.88 454 1.75 44 6.06 154 .625 15.9 WK-294651-000 600 22.00 559 21.56 548 25.75 654 24.12 613 1.75 44 10.25 260 .625 15.9 06-236125-001 900 24.00 610 23.75 603 27.75 705 26.00 660 1.75 44 12.13 308 .625 15.9 MATERIALS Steel, Painted Black SAE 1020 COMPATIBILITY Series ForUse With Kidde ECS HFC-227ea X Kidde ECS Advanced Delivery FM-2000 X This literature is provided for informational purposes only. KIDDE- FENWAL, INC. assumes no responsibility forthe product's suitability for a particular application. The product must be properly applied to work correctly. If you need more information on this product, or if you have a particular problem or question, contact KIDDE-FENWAL, Inc. 02014 Kidde-Fenwal, Inc. FM-200 is a registered trademark of E.I. du Pont de Nemours and Company. Kidde is a registered trademark of Kidde-Fenwal Inc. All other trademarks are the property of their respective owners. Kidde Fire Systems 400 Main Street Ashland, MA 01721 Ph: 508.881.2000 Fax: 508.881.8920 www.kiddefiresystems.com Kidde ECS Fire Suppression System Component Description Valve Outlet Adapters FEATURES For Use with UL Listed, ULC Listed and FM Approved Systems 40 Kidde Fire Systems Effective: June 2014 K-90-21 00 Rev BA RoHS Compliant B (VALVE OUTLET CONNECTION) C (SYSTEM PIPE CONNECTION) Note: For direct connection of cylinder valve to distribution piping. MATERIAL Brass ORDERING INFORMATION Dimensions Part Number Size (in inches) A B C D WK-283904-000 11/2 1-1/2 1.874 2.69 2.50 HEX 11-1/2 NPT 12 UNJ WK-283905-000 2 2 2.500 3.12 3.00 HEX 11-1/2 NPT 12 UNJ WK-283906-000 21/2 2-1/2 3.00 3.00 3.75 HEX 8NPT 12 UNJ COMPATIBILITY Series For Use With Kidde ECS HFC-227ea X Kidde ECS Advanced Delivery FM-2000 X This literature is provided for informational purposes only. KIDDE- FENWAL INC. assumes no responsibility for the product's suitability for a particular application. The product must be properly applied to work correctly. If you need more information on this product, or if you have a particular problem or question, contact KIDDE-FENWAL, Inc. 02014 Kidde-Fenwal, Inc. FM-200 is a registered trademark of E.I. du Pont de Nemours and Company. Kidde is a registered trademark of Kidde-Fenwal Inc. All other trademarks are the property of their respective owners. Kidde Fire Systems 400 Main Street Ashland, MA 01721 Ph: 508.881.2000 Fax: 508.881.8920 www.kiddefiresystems.com Kidde ECS Fire Suppression System Component Description 180 Degree Pendant Nozzle fKidde Fire Systems Effective: June 2014 K-81-91 50 Rev BA FEATURES For Use with UL Listed, ULC Listed & FMRC Approved Systems RoHS Compliant P/N: 90-19401X-XXX METAL STAMP X-XXX (DASH NO.) IN .093.031 HIGH CHARACTERS ON ANY FLAT A Pipe Size A B C D 1/2" (12.20 mm) 1.25" (31.75 mm) 1.250" (31.75 mm) 1.687" (42.84 mm) 2.000"(50.80 mm) 3/4" (19.05 mm) 1.50" (38.10 mm) 1.375" (34.92 mm) 1.950" (48.89 mm) 2.296" (58.31 mm) (25.40 mm) 1.75" (44.45 mm) 1.562" (39.67 mm) 2.218" (56.33 mm) 2.671" (67.84 mm) IYI'(31.75 mm) 2.25" (57.15 mm) 1.750" (44.45 mm) 2.656" (67.46 mm) 3.250" (82.55 mm) 1W (38.10 mm) 2.50" (63.50 mm) 1.950" (48.89 mm) 2.950" (74.93 mm) 3.625"(92.07 mm) (50.80 mm) 3.00" (76.2 mm) 1 1.968" (49.98 mm) 2.875" (73.02 mm) 3.656" (92.86 mm) Note: A selection of orifices are available for each nozzle size. Consult your Kidde Design and Installation Manual for details. COMPATIBILITY Series For Use With Kidde ECS HFC-227ea X This literature is provided for informational purposes only. KIDDE- FENWAL INC. assumes no responsibility for the product's suitability for a particular application. The product must be properly applied to wo-k correctly.If you need more information on this product, or if you have a particular problem or question, contact KIDDE-FENWAL, Inc. 02014 Kidde-Fenwal, Inc. Kidde is a registered trademark of Kldde-Fenwal Inc. All other trademarks are the property of their respective owners. Kidde Fire Systems 400 Main Street Ashland, MA 01721 Ph: 508.881.2000 Fax: 508.881.8920 www.kiddefiresystems.com AEGISTM Conventional Fire Alarm-Suppression Control Unit Kidde Fire Systems A UTC Fire & Security Company Effective: November 2007 K-84-100 FEATURES Agency Approvals cFMus Approved to NFPA 72, ANSI 864, 9th edition and ULC-S527-99 CSFM Approved MEA Approved cULus Listed to ANSI 864, 9th edition and ULC-5527-99 Suppression focused Control Unit Listed for a Wide Range of Suppression Systems Kidde FM2000, FE13, Cob 3MM Novec 123OTM Fire Protection Fluid, Argonite1", and Halon Clean Agents Kidde INDTM Dry Chemical & WHDRTM Wet Chemical Systems Sprinkler Supervisory Service Deluge, Preaction, Foam, Foam-Water Systems Combination Clean Agent plus Pre-Action System Built-in Class-A and Class-B Circuitry Sophisticated Programmable Notification Appliance Circuits Independently Programmable Agent Releasing Circuits with Triple-R Protection DESCRIPTION The Kidde AEGIS is the technologically most advanced Conventional Single Hazard Agent Releasing Unit available to the Fire-Alarm Suppression industry today. It combines the high quality, system reliability, and flexibility required by modern commercial, high-tech and industrial applications in an aesthetically pleasing and physically robust package. The AEGIS is well equipped to handle all special hazard extinguishing systems due to the high degree of programming flexibility provided and the following full complement of input and output circuits: Three (3) Class A or Class B Detection Circuits Two (2) Class A or Class B Supervisory Circuits One (I) Class A or Class B Manual Release Circuit One (I) Class A or Class B Abort Input Circuit Three (3) Class A or Class B Notification Appliance Circuits Two (2) Class B Agent Release Circuits Four (4) Form-C Relays Input and Output 3 Detection Circuits 2 Supervisory Circuits I Manual Release Circuit I Abort Input Circuit 3 Notification Appliance Circuits 2 Release Circuits 4 Form-C Relays Programmable Relays Robust Power Supply Elegant User-Interface Simple Configuration Password Protected Digital Release Countdown Battery Voltage and Charging Current Display Extensive Diagnostics Backwards Compatible Improved and Enlarged Cabinet Design 5-Year Warranty )ETECTION CIRCUITS The Detection Circuits can support up to 25 Conventional CPD-705x Ionization Smoke, PSD-71 5x Photoelectric Smoke, or THD-705x Heat Detectors each as well as Normally Open contact closure type devices. Two circuits are dedicated to the main suppression function and can be programmed to activate the release circuits by either single-shot or cross-zone input. The user-configuration allows automatic release via detection to be delayed from 0 to 60 seconds in 10-second intervals and also allows a choice of which of the two Agent Release Circuits to activate. The third Detection Circuit is programmable for either Waterflow or as an independent Detection circuit. When programmed for Waterfiow, Notification Appliance Circuits can be programmed as Non-Silenceable as required by certain jurisdictions. SUPERVISORY CIRCUITS The Supervisory Circuits accept Normally Open contact closure type devices such as pressure switches on the agent cylinders or on the water or air pipe network. The system configuration enables the supervisory input to be a participant in the suppression function. For example, low air supervisory can be included with detection for release of pre-action systems as required by certain 'jrisdictions. SUPERVISORY SUPERVISORY 2 1 MANUAL RELEASE AND ABORT CIRCUITS Both the Manual Release and Abort Circuits accept Normally Open contact closure type devices. Activation of the Agent Release Circuits can either be instantaneous or delayed up to 30 seconds (maximum) upon receipt of Manual Release input. Agent release can be temporarily delayed by activating the Abort Circuit. The Abort input can be programmed for 5 modes of operation. These include the UL 10-second mode, the full-delay mode, the IRI mode, the NYC mode, or the abort can be disabled. Aborts can also be programmed to be applicable for either one or both Agent Release Circuits thereby allowing use with Deluge/Pre-Action systems. NOTIFICATION APPLIANCE CIRCUITS (NAC) The three Notification Appliance Circuits are rated 1.5 Amps each and accept polarized 24 Vdc Notification Appliances. Each circuit is driven independently and is user configurable for First Alarm, Pre-Release, and Releasing as well as for 60 BPM, 120 BPM, Temporal, or Continuous pattern. The MT and NS series appliances provide the option to use silenceable horns and non-silenceable strobes on the same NAC. Multiple NAC circuits (connected to audible devices only) programmed with the same master code pattern are synchronized, regardless of any differing starting times that preceded their concurrent operation. The NACs configuration includes a user- selectable intelligent synchronization feature which allows a silenceable horn to be shut off while the strobe continues to flash in synchronized fashion. MANUAL WA1EP.FLOWI ABORT RELEASE DETECTORS DETECIOR2 AC IN 137 TEE 0 135 184 TEE 182 STBS S J 181 0 189 TEED r o O o- OfKicIde 1 Fire Systems a i: Omj 181 El el AC SUPPLY SELECT SWITCH (SS) / i•l T/m14 1815 1816 5517 ISlE 111 - J 13 00 00 __ 0 1813 ,., REM* *..., .., RELEASE I RELEASE 2 SUE NAC 3 MCI AR02 24VDC Figure 1. Printed Circuit Board (PCB) TROUBLE RELAY 3 RELAY 2 RELAY 1 BATT OUT DETECTOR 1 NAC I MAC 2 -2- BUILT-IN CLASS A AND B CIRCUITRY For the input and NAC circuits, the choice of Class A or Class B supervision is made at site on the board itself by selecting the terminals used for wiring. Neither conversion boards nor additional hardware nor jumper selection is required for this purpose. AGENT RELEASE CIRCUITS (ARC) The two circuits can be programmed for activation by different inputs, with independent time delays and abort modes to fire combinations of two of the following releasing devices: I or 2 Kidde Continuous and Momentary Solenoid Control Heads I Kidde Initiator I Factory Mutual Group A, B, D, E, F, G, I, J, or K Solenoid In other words, operating in tandem, the two circuits can release: I or 2 Control Heads on ARCI and I or 2 Control Heads on ARC2 I or 2 Control Heads on ARCI and I Initiator on ARC2 or vice-versa I or 2 Control Heads on ARCI and I FM Sprinkler Solenoid on ARC2 or vice-versa I Initiator on ARCI and I Initiator on ARC2 I FM Solenoid on ARCI and I FM Solenoid on ARC2 This configurability is useful for those jurisdictions where the gaseous suppression agent is required to be supplemented with a pre-action system. TRIPLE-R PROTECTION FOR AGENT RELEASING CIRCUITS (ARC) The two ARCs feature a triple failure redundancy safeguard system to protect them from inadvertent activation by the main microprocessor. The Triple-R system requires that in order to activate an ARC, the main microprocessor issues two release commands of opposing polarity via separate channels and that these commands be combined with a third signal from the panel watchdog timer to confirm the microprocessor operation. The Triple-R system ensures that electrical transients or disturbances such as power surges that could interfere with the operation of the nlain microprocessor will not inadvertently activate the connected suppression system. The result is a more robust and reliable suppression-focused panel. PROGRAMMABLE RELAYS Of the 4 relays, three are user-programmable for a variety of alarm related conditions and the fourth is a dedicated trouble relay. All relay contacts are rated 3.0 Amps at 30 VdcI120 Vac (resistive). POWER-LIMITED CIRCUITRY All circuits, excluding ARCs are inherently power-limited. Agent Release Circuits, except when firing Initiators, can also be made power-limited by a field located inline releasing diode device thereby allowing cost effective installation with all wiring in the same conduit. ROBUST POWER SUPPLY UNIT (PSU) The AEGIS features a universal 120/240 V, 50/60 Hz AC Power Supply Unit with a robust 5.4 Amps of 24 Vdc power. Input voltage selection is via a slider switch with no jumper cutting required. The on-board battery charger is able to charge 24 Vdc (2 x 12) batteries of capacity up to 68 Ah thereby allowing from 24 hours of supervision plus 5 minutes of alarm to 90 hours of supervision plus 10 minutes of alarm required by some jurisdictions. AUXILIARY POWER SUPPLY Up to I Amp of auxiliary power at 24 Vdc is available to power external 4-wire devices such as Flame Detectors, AlarmLine modules, Duct Detectors, etc. ELEGANT USER-INTERFACE The user-interface consists of an array of LED Indicators, Control Switches, a Digital Display, and Buzzer. Over and above the System, Power Supply status, Input circuit Fire and Trouble and Output circuit Trouble LEDs, the AEGIS annunciates its suppression state-of-alarm via three additional Pre-Release, Releasing and Post Release LEDs. Four switches are provided, one each for Acknowledge, Signal Silence, System Reset and Output Disable. The 3-digit display provides a countdown of impending agent release. On command from the user- interface switches, it also indicates the battery open circuit voltage and charging current. SIMPLE SITE-SPECIFIC CONFIGURATION Accessed via the digital display and user-interface switches, site-specific configuration is simple, yet detailed and can typically be performed in a matter of minutes. To prevent unauthorized use, the configuration menu is protected by a user-changeable password. Factory technical support can provide assistance with lost or forgotten passwords. Apart from the input voltage selection performed on both the PSU and main board via a slider switch, no other on- board settings or jumper cuttings are required. EXTENSIVE DIAGNOSTICS Also initiated via the digital display and user-interface switches, the troubleshooting function displays diagnostic codes that assist in determining causes of trouble. A complete list of diagnostic codes and their meaning ships factory installed on the inside of the enclosure door for easy reference. -3- ACKWARDS COMPATIBILITY onsistent with previous generation Kidde control equipment, the AEGIS is listed to be backwards compatible with the full range of Kidde-Fenwal conventional detectors, alarm devices and suppression accessories. Going forward, this will allow older generation panels to be replaced with relative ease. IMPROVED AND ENLARGED CABINET DESIGN The cabinet design allows for easy installation by fitting between the studs of a standard 16 inch studded wall. It is large enough to house two 12 Vdc, 12 Ah Batteries and provides up to 2 inches (51 mm) of wiring and finger space between the circuit board and the cabinet wall. An optional door design features a Manual Release and Abort switch for applications with space constraints. Both switches incorporate guards that prevent their inadvertent activation. Other cabinet options include a flush mounting trim-ring and a dead-front plate required for Canadian applications. TECHNICAL SPECIFICATIONS Hazards Protected -One Power Supply - 120/240 Vac, 50/60 Hz (90 to 264 Vrms, 47 to 63 Hz) AC Main Input - 5.4 Amps at 27 Vdc Output - Battery capacity up to 68 Ah @ 24 Vdc - Auxiliary power output rated at I Amp at 18.8-27.6 Vdc (resettable) Three (3) Detection Circuits - Compatible with up to 25 CPD-705x, PSD-71 5x, and THD-705x detectors and normally open contact-closure type devices - Configurable as Class A/Style D or Class B/Style B - Supervised for ground faults and open circuits - Power limited - DET 1 and DET 2 used for suppression - DET3/WF configurable for detection or waterfiow One (1) Manual Release Circuit - Compatible with normally open contact-closure type devices - Configurable as Class A/Style D or Class B/Style B - Supervised for ground faults and open circuits - Power limited TECHNICAL SPECIFICATIONS (cont'd) One (1) Abort Circuit - Compatible with normally open contact-closure type devices - Configurable as Class A/Style D or Class B/Style B - Supervised for ground faults and open circuits - Power-limited Two (2) Supervisory Circuits - Compatible with normally open contact-closure type devices - Configurable as Class A/Style D or Class B/Style B - Supervised for ground faults and open circuits - Power-limited Three (3) Notification Appliance Circuits (NACs) - Compatible with polarized 24 VDC Audio-Visual devices - Rated at 1.5 Amps each - Configurable as Class A/Style Z or Class B/Style Y - Supervised for ground faults, shorts, and open circuits - Power-limited - Common NAC/ARC output disconnect switch Two (2) Agent Release Circuits - Each compatible with I or 2 control heads, or 1 initiator, or I FM sprinkler solenoid - Circuits electrically capable of simultaneously releasing any combination of two of the above devices - Factory configured as Class B/Style Y - Supervised for ground faults and open circuits - Non-power-limited. May be power-limited (except with initiators) and supervised for short circuit using inline releasing resistor-diode device - Common NAC/ARC output disconnect switch Four (4) Relays - 3 independently programmable, normally de- energized Form-C - I dedicated normally energized Form-C Trouble Relay - Relay contacts rated 3 Amps at 30 Vdc/120 Vac (resistive) -4- TECHNICAL SPECIFICATIONS (cont'd) ORDERING INFORMATION Enclosure - NEMA I rated 18 gauge sheet steel with door - Red color - Suitable for wall and surface mounting - Optional Trim Ring - Optional Dead-Front Panel - Optional door with Manual Release and Abort switches - Dimensions: -with Standard Door: 14-1/4 in. W x 5 in. Dx19in. H (362 mm x 127 mm x 483 mm) - with Switch Door: 14-1/4 in. W x 6 in. Dx19in. H (362 mm x 152 mm x 483 mm) Environmental Criteria - Indoor/Dry use only - Operating temperature range: 32°F to 120°F (0°C to 49°C) - Humidity: 93:L 2% RH at 90 ± 3°F (32 ± 2°C) Packaging/Shipping - Enclosure, PCB, and PSU packaged in individual cartons - Accessories shipped include mounting hardware, battery leads, IOM manual on CD-ROM, operating instruction sheet, and EOL resistor kit - Order inline releasing resistor-diode device (if required) and batteries separately Description Part Number Kidde AEGIS Control Panel 84-732001-001 Kidde AEGIS Control Unit with Switches 84-732001-201 In-Line Releasing Diode (10K) Kit 06-220023-001 Trim Ring 76-600000-007 Dead-Front Panel* 06-220175-001 Battery Enclosure 76-100010-001 Kidde AEGIS Conventional Fire Alarm-Suppression Control Unit IOM Manual 06-236716-001 Kidde AEGIS User's CD 06-236727-001 Installation/Configuration Kit 06-220148-002 Operating Instructions 06-236719-002 Replacement Hardware Installation Kit 06-220149-001 Replacement Enclosure Assembly 06-220172-002 Replacement Enclosure Assembly (with Switches) 06-220174-002 Replacement Switch Kit 06-220176-001 Replacement PCB Assembly 06-220150-001 Replacement Power Supply 06-118394-002 Replacement Bezel Assembly 06-220151-001 Spare Key 06-118013-001 Spare Keylock with Keys 06-129924-001 EOL Backbox (Canadian applications only) 06-129963-002 Battery Harness 06-129925-002 Tor Canadian applications, order Control Unit and Dead-Front Panel separately. -5- Kidde is a registered trademark of Kidde-Fenwal, Inc. AEGIS and Gemini are trademarks of Kidde-Fenwal, Inc. FM-200 is a registered trademark of Chemtura. FE-13 is a registered trademark of DuPont. 31VIm1 NovecTM 1230 Fire Protection Fluid is a trademark of 3M. ArgoniteiM is a registered trademark of Ginge Kerr For detailed installation, operation, and configuration information, refer to the Kidde AEGIS Conventional Fire Alarm-Suppression Conventional Unit Installation, Operation, and Maintenance Manual P/N 06-236716-001. This literature is provided for informational purposes only. KlDDEFENWAL, INC. I fKidde Fire Systems assumes no responsibility for the product's suitability for a particular application. The I product must be properly applied to work correctly. I If you need more information on this product, or if you have a particular problem or ques- I A UTC Fire & Security Company tion, contact KIDDE-FENWAL INC., Ashland, MA 01721. Telephone: (508) 881-2000. 400 Main Street Ashland, MA 01721 Ph: 508.881.2000 K-84-100 Rev AC © 2007 Kidde-Fenwal Inc. Printed in USA Fax: 508.881.8920 wwwkiddefiresystems.com Kidde ECS Fire Suppression System Component .Description Electric Control Head 0-0 Kidde Fire Systems Effective: June 2014 K-90-8010 Rev BA FEATURES For Use with UL Listed, ULC Listed and FM Approved Systems PIN: WK-890i81-000 CONNECTION FOR FLEXIBLE ELECTRIC CONDUIT- 3/4" NPT FEMALE ,- LOCKING PIN SEAL WIRE CONTROL HEAD 6.18" V02 Q (157mm) INDICATOR AND --• RESET STEM SET RELEYEED -. 4.00" - (102mm) LOCAL MANUAL RELEASE LEVER SWIVEL NUT 1.50" (38mm) HEX 1-1/4-18 NF-3 THREAD Ordering Information Part Number Control Head Voltage Current WK-890181-000 24 VDC 2.OA COMPATIBILITY Series For Use With Kidde ECS HFC-227ea X Kidde ECS Advanced Delivery FM2000 X This literature is provided for informational purposes only. KIDDE- FENWAL, INC. assumes no responsibility forthe products suitability for a particular application. The product must be properly applied to work correctly. If you need more information on this product, or if you have a particular problem or question, contact KIDDE-FENWAL, Inc. 02014 Kidde-Fenwal, Inc. FM-200 is a registered trademark of E.I. du Pont de Nemours and Company. Kidde is a registered trademark of Kidde-Fenwal Inc. All other trademarks are the property of their respective owners. Kidde Fire Systems 400 Main Street Ashland, MA 01721 Ph: 508.881.2000 Fax: 508.881.8920 www.kiddefiresystems.com 'I In-Line Releasing Device .. fKidde Fenwal Installation Instructions Effective: November 2004 ..... ... .._ ......flS.. . ........I%• S..-......_. S.4 . •4.........- ...a 5 DESCRIPTION The In-Une Releasing Device, P/N 08-220023-001,18 used to make a single-or dual-solenoid releasing circuit power limited. See Figure 1. Figure 1. In-Line Releasing Device SUPPLIED PARTS In-Une Releasing Device, P/N 06-220023-001 REQUIRED TOOLS No.2 Flat-Head Screwdriver. Small Flat-Head Screwdriver. PROCEDURE The In-Line Releasing Device Is polarity-sensitive and must be connected as shown In Figure 2 for a single- solenoid circuit or as shown in Figure No. 3 for a dual- solenoid circuit. The red lead of the In-Line Releasing Device must be connected to the field wiring from Terminal I of the re- leasing circuit. The black lead must be connected to the control head or solenoid valve. Use wire-nuts to connect the in-Line Releasing Device to field wiring and leads from control heads and sole- noid valves. Red Control Head for Agent Storage Black Red Container or Solenoid Mve for Spunkier System Release- Cooi [''' Circuit Terminals JUNCTION BOX (enlarged for clarity) Note: Junction box for In-Line Releasing Device must be close nippled to control head or enclosure for solenoid valve. Figure 2. Single-Control-Head or -Solenoid Releasing Circuit Release-Circuit Terminals I 1 Red Black Control Head forAgent Storage Red Container iu11 or Black Solenoid MM for Spdnlder System Red Black ID1 Control Head forAgent Borage L= ~Red cwbbw JUNCTION BOX or (enlarged for clarity) Black SolenoId Valve for Sdnlder System Note: Junction box for In-Line Releasing Device must be dose nippled to control head or enclosure for solenoid valve. Use separate Junction boxes when control heads or solenoid valves are remote from each other. Figure 3. Dual-Control-Head or -Solenoid Releasing Circuit Kiddo.F.uwiI I. a rustn,ud t,adetnaik of KIddePsnwaI. RM This IlIorsh,s Is wnoIded for inlonnoUoiiul pwposu cnI mDoE-FENWALelc. uuumaa no rnponstailiiytarlh.praducra aWlsbmty for oparticular uppHcaUo. ma Plotted must be pop - Orly applied bmuti carruciI if you used more Intonation an ft prod.ct or If you haven particular probism of question, contact KIDOE-PENWAt. INC.. MNand, MA 01721. Tiaphone: (50$) 5e1-2000 06-236541-001 RevAA 0206$ Kidde-Fenwal Inc. Printed In USA VK idde Fenwal Kldde-Fenwaf, lnc.O 400 Main StreetD Ashland, MA 01721 U.S.A.O www.kldde4enwaLcom Effective: September 2008 Advanced Photoelectric Smoke Detectors Models PSD-7157 and PSD-7157D F-70-02 FEATURES Approvals/Listing US and Canadian UL Listed (cULus) FM Approved CSFM Approved NYC MEA Accepted Nominal Sensitivity PSD-7157: 3.25% per ft. Obscuration PSD-7157D: 2.40% per ft. Obscuration Sensitivity Measurementllesting Wireless Measurement in °/Jft. Obscuration Remote and Local Functional Test Capability Wide Range of Input Voltage 10.2 to 36.8 Vdc Low Current Design Dual Response LEDs Allow 360-degree Viewing Trouble Indication Low Profile Appearance Using Surface Mount Technology Electrically and Mechanically Compatible with all Fenwal Smoke and Electronic Heat Detectors and Bases Interchangeable 2-Wire and 4-Wire Bases Universal Relay Modules Non Polarized Locking Feature for Vandal Resistance Fine Mesh Insect Screen EMI and RFI Resistant DESCRIPTION The Fenwal Models PSD-7157 and PSD-71570 Photoelectric Smoke Detectors respond to a broad spectrum of both flaming and smoldering fire conditions. The Detectors have advanced solid-state, low-voltage, surface-mount circuitry and are designed for 2-Wire and 4-Wire installation using the appropriate Detector base. The characteristic 360-degree detector design permits smoke entry from any direction. A unique sensing chamber design permits the operation of the Models PSD-7157 and PSD-7157D in open areas with air velocities from 0 to 300 fpm and 0 to 4000 fpm respectively. The Model PSD-71 57D is also suitable for duct housing applications in air velocities from 500 to 4000 fpm. The Detectors are designed for open area/ duct housing applications per UL268/UL268A and may be installed in systems intended for Releasing Device Service through use of compatible Fire Alarm Control Panels. EFENWAL Protection Systems A UTC Fire & Security Company Two Red Light Emitting Diodes are located diametrically opposite each other so as to allow 360-degree viewing. Both LEDs continuously indicate the operating condition of the Detector. During standby, the LEDs flash once every six seconds. During alarm, both LEDs light steady at full brilliance. A double flash every six seconds indicates a detector with a sensitivity threshold outside acceptable limits. A unique gated output circuit design provides improved stability and transient suppression. Special signal processing techniques verify the presence of smoke before the detector will alarm. A fine mesh insect screen protects the chamber area and is used to avoid potential nuisance alarms. The detector head is installed into the base with a simple twist-lock action. A locking feature is provided for vandal resistant security. Table I lists the Technical Specifications for Models PSD- 7157 and PSD-7157D Photoelectric Smoke Detectors. CONTROL UNITS The Models PSD-7157 and PSD-7157D Detectors are designed for operation with control units and releasing devices having specific voltage and current characteristics that are compatible with the detector circuitry. The Detectors are compatible with the Fenwal 732 control unit. The Fenwal 732 has three detection circuits which can support up to 26 detectors per circuit. Table 1: Technical Specification Model Number PSD-7157 PSD-7157D Part Number 71-570000-001 71-570000-002 Detection Photoelectric Photoelectric Approvals cULüs, FM, CSFM, MEA-NYC cULus, FM, CSFM, MEA-NYC UL Compatibility I.D. P55FE1 P55FEI Listed Spacing 30 ft. (9.1 m) centers or 900 ft.2 (83.6 m2) 30 ft. (9.1 m) centers or 900 ft.2 (83.6 m2) Nominal Sensitivity 3.25% + 0.45% - 1.78% per foot 2.40% + 0.04% - 1.34% per foot Obscuration Obscuration Standby Voltage (Vdc) Using 2WB: 10.2 to 36.8 10.2 to 36.8 Using 4WRB: 16.8 to 36.8 16.8 to 36.8 Maximum Current Standby: 70 pA 70 pA Alarm: 100 mA 100 m Response Indicators Quantity: 2 external LEDs 2 external LEDs Standby Condition: One flash every 11 seconds One flash every 11 seconds Thermistor Trouble: Double flash every 11 seconds Double flash every 11 seconds Alarm Condition: Steady at full brilliance Steady at full brilliance Operating Environment Operating Temperature: 32° to 120°F (0° to 49°C) 32° to 120°F (0° to 49°C) Storage Temperature: -20° to 180°F (-29° to 82°C) -20° to 180°F (-29° to 82°C) Relative Humidity: 0 to 93% Non-condensing 0 to 93% Non-condensing Air Velocity Open Area: 0 to 300 fpm (0 to 1.5 m/s) 0 to 4000 fpm (0 to 20 m/s) Duct Housing: N/A 500 to 4000 fpm (2.5 to 20 m/s) Altitude: Up to 7,500 feet (2,286 m) Up to 7,500 feet (2,286 m) Physical Characteristics Material and Finish: High-impact, flame-retardant plastic, off white High-impact, flame-retardant plastic, off white Weight: 35.3 oz. (hOg) w/o base 35.3 oz. (hOg) w/o base Dimensions Detector Height: 1-3/8 in. (35 mm) 1-3/8 in. (35 mm) Detector Diameter: 3-29/32 in. (99 mm) 3-29/32 in. (99 mm) Base Height: 3/64 in. (11 mm) 3/64 in. (11 mm) Base Diameter: 5-29/32 in. (150 mm) 5-29/32 in. (150 mm) DETECTOR BASE OPTIONS The Models PSD-7157 and PSD-7157D can be used with the detector base options and accessories in Tables 2. Various base options are available to provide auxiliary relay and/or remote indication and remote test feature. The Models PSD-7157 and PSD-71570 Photoelectric Smoke Detectors may be interchanged with other Fenwal Series THD-705X Electronic Heat Detectors and Series CPD-705X Ionization Smoke Detectors when using multifunctiôn base configuration. -2- SPACING (OPEN AREA LOCATION) The Models PSD-7157 and PSD-7157D Detectors are listed to be installed on maximum 30 ft. (9.1 m) centers, typically on smooth ceilings up to 15 ft. (4.6 m) high and will operate with minimum air circulation. Resultant maximum 900 square foot (83.6 m2) spacing may be used as a reasonable guide for comparable applications. Where special conditions exist (ceiling obstructions, high air exchange rates, etc.), reduced spacing must be used to achieve adequate protection. Computer rooms and other such installations may require spacing with a maximum of 200 ft.2 (18.6 m2) due to high air exchange rates. Detectors should not be located in areas with excessive exhaust fumes, kitchen areas, near fireplaces or furnace rooms and within three (3) ft. (.9 m) of air supply ducts or air diffusers. For additional information, consult the Fenwal Automatic Fire Detection Application Engineering Manual MC-402, NFPA-72 and the local Authority Having Jurisdiction. WIRING DIAGRAMS For detailed wiring diagrams with Fenwal 2- and 4-wire bases, please refer Fenwal Document 70.104 INSTALLATION Detector bases are directly mounted on the electrical junction boxes (3-inch, 3-1/2-inch and 4-inch octagonal, 3-inch round or 4-inch square) (76 mm, 89 mm, 102 mm octagonal, 76 mm round or 102 mm square) without the need for any mechanical adapter required. Refer Fenwal Document 06-235056-001 for additional details. The detector bases also include a locking feature that prevents removal of the detector without use of a tool. TESTING AND MAINTENANCE Testing shall be performed upon installation of the detector and once a year thereafter as stated in NFPA-72 latest edition. Detector sensitivity shall be checked within one year of installation and every alternative year thereafter as stated in NFPA 72. Refer Fenwal Documents 06-236524-001 and 06-235056-001 for details on using the Infrared Wireless Sensitivity Tester Model DST-003. The tester provides direct readout in percent per foot obscuration from a distance of 15 ft. without removing the detector from its base. A go/no-go test can be performed using a test magnet. The recommended requirement for detector maintenance consists of an annual cleaning of dust from the detector head by using the suction of a vacuum cleaner. Cleaning programs should be geared to the individual environment in conformance with NFPA 72. Do not attempt disassembly of the fac- tory sealed smoke detector. This assembly is sealed for your protection CAUTION and should not be opened for servic- ing. Opening of the detector will void its warranty. SPARE PARTS The Models PSD-71 57 and PSD-71 57D Detectors are factory repairable only and have no field serviceable spare parts. No field repair should therefore be attempted. For service, return detector head intact to Fenwal. ARCHITECT/ENGINEER SPECIFICATIONS The contractor shall furnish and install where indicated on the plans, UL268/UL268A listed Photoelectric Smoke Detectors, Fenwal Models PSD-71 57 and PSD-71 57D. The combination detector head and twist-lock base shall be UL Listed compatible with a UL Listed fire alarm control unit. The Models PSD-7157 and PSD-7157D Photoelectric Smoke Detectors shall share interchangeable bases with the CPD-7054 and CPD- 7054D Ionization Smoke Detectors and the THD-7052 and THD-7053 Heat Detectors. The Fenwal Models PSD-7157 and PSD-7157D Photoelectric Smoke Detectors shall have two Red LEDs located diametrically opposite each other so as to allow 360-degree viewing. The LEDs shall continuously indicate the operating condition of the Detector. During standby, the LEDs shall flash once every six seconds. During alarm, both LEDs shall light steady at full brilliance. If the sensitivity of the detector drifts outside acceptable limits, the LEDs shall double flash every six seconds. The detector may be reset by actuating the control panel reset switch. The vandal-resistant security locking feature shall be used in those areas as indicated on the drawings. The locking feature shall be field removable when not required. It shall be possible to measure the sensitivity of the Fenwal Models PSD-71 57 and PSD-71 57D Photoelectric Smoke Detectors from a distance of up to 15 feet (4.6 m) without removal from the base. Measurement shall be accomplished with a wireless infrared Fenwal Sensitivity Tester (DST-003) allowing direct measurement in percent per foot obscuration. Sensitivity measurement techniques requiring wiring between the Detector-Base combination and the Tester shall not be acceptable. It shall also be possible to perform a functional test of the detector without the need for generating smoke. -3- The Fenwal Models PSD-7157 and PSD-71570 Photoelectric Smoke Detectors shall operate over an input voltage range from 10.2 to 36.8 Vdc. Voltage and RF transient suppression techniques to withstand up to 20 volt/meter shall be employed to minimize susceptibility to false alarms. Supplementary SPDT relays, remote test, and/or remote LED alarm indicators shall be installed where indicated Table 2: Ordering Information Part Number Model Description Detector Heads - Ionization Smoke 70-540000-001 CPD-7054 Ionization Advanced Smoke Detector (cULus) 70-540000-002 CPD-70540 Ionization Advanced Smoke Detector (cULus) Detector Heads - Photoelectric Smoke 71-570000-001 PSD-7157 Photoelectric Advanced Smoke Detector (cULus) 71-570000-002 PSD-7157D Photoelectric Advanced Smoke Detector (cULus) Detector Heads - Heat 70-520000-001 THD-7052 135°F (57°C) Fixed Heat Detector, 15°F (-9°C) Rate of Rise (cULus) 70-530000-001 THD-7053 135°F (57°C) Fixed Heat Detector (cULus) Detector Bases 70-501000-001 2-Wire 2-Wre Standard Base. Connects to circuit via screw terminals. (CID = FESIA) 70-501000-002 2WRLT 2-Wre Base w/ Remote LED & Test capabilities. Connects to circuit via screw terminals. Minimum Alarm Current 15 mA @ 24 Vdc. (CID =FE52A) 70-501000-005 2WRB 2-Wre Base WI 2WRM, Remote LED & Test capabilities. Connects to cir- cuit via pigtail leads. Minimum Alarm Current 19 mA @ 24 Vdc. (CID = FE55A) 70-501000-101 4WRB 4-Wre Base w/ 4WRM, Remote LED & Test capabilities. Connects to cir- cuit via pigtail leads. Minimum Alarm Current 35 mA@24Vdc. 70-500000-004 2WRM Spare SPDT Relay for 2WRB Bases. Contacts rated 1.0 A, 30 Vdc/0.5 A, 125 Vac. Detector Accessories 06-117883-001 'Test Magnet 29-116788-001 EOL Supervisory Relay 70-200000-911 RA-911 Remote Alarm Indicator 70-200000-914 RA-914 Remote Alarm Indicator with Smoke Detector Switch 70-500000-003 DST-003 Advanced Handheld Wireless Smoke Detector Sensitivity Tester 70-501000-003 MA-001 Mechanical Retrofit Adapter. Allows CPD-705X and PSD-715X Detectors to physically connect to Base P/Ns 70-201000-001, -002, -003, -005 & DH-22. (CID = MAFEI) This literature is provided for informational purposes only. KIDDE-FENWAL INC. assumes no responsibility for the product's suitability for a particular application. The product must be properly applied to work correctly. If you need more information on this product, or if you have a particular problem or ques- tion, contact KIDDE-FENWAL, INC., Ashland, MA 01721. Telephone: (508) 881-2000. F-70-02 Rev AE @2008 Kidde-Fenwal Inc. Printed in USA NFEProtection Systems A UTC Fire & Security Company 400 Main Street Ashland, MA 01721 Ph: 508.881.2000 Fax: 508.881.8920 www.fenwalfire.com Key Maintenance Switch fr e l idde Fire Systems A UTC Fire & Security Company Effective: May 2009 K-76-606 FEATURES cFMus Approved to ANSIIUL 864, 9th edition, CANADAIULC-5527 and ANSIINFPA 72 Stainless Steel Plate Status LED Indicators Surface or Flush Mount Installations DESCRIPTION This Key Maintenance Switch is a key-switch that discon- nects actuation circuits in the system to prevent acciden- tal discharge of fire suppression systems during maintenance operations. The Key Maintenance Switch provides a means to short the Metron Actuator circuit leads for safe disconnection of conventional and addressable control units. Refer to the installation wiring diagram for detailed wiring connec- tions. Two LEDS indicate "SYSTEM ARMED" or "SYSTEM INACTIVE" when the key is inserted and turned. The key can only be removed in the armed position. Key Maintenance Switch mounts to a 4-inch backbox and operates on 24 Vdc. Designed for mounting on the wall with a back box. Key Maintenance Switch can be installed in either surface mount or flush mount configurations. Key Maintenance Switch physically disconnects the release circuit wiring in addition to the trouble open signal, the switch provides a means to generate a supervisory condition. ORDERING INFORMATION Part Number Description 76-600000-200 Key Maintenance Switch 06-236881-001 Backbox Safely Disconnects Actuation Circuits by Shorting Metron Actuators Key Operated (Nonremovable When Operated) Four-Pole Double-Throw Switch Meets the Requirements of NFPA72 (2007 edition) ELECTRICAL Switch: 4PDT Key Switch - one set of contacts control indicators on the faceplate. - Three remaining contacts are available for application wiring. Device Current: 10 A @ 250 Vac 15A@ 125 Vac 15 A @ up to 30 Vdc Electrical Life: 50,000 cycles - maintained 25,000 cycles - -momentary ENVIRONMENTAL Operating Temperature 32 to 120°F (0 to 49°C) Range: MECHANICAL Mechanical Life: 100,000 cycles Switch Plate Stainless Steel Construction: This literature is provided for informational purposes only. KIDDE-FENWAL, INC. assumes no responsibility for the product's suitability for a particular application. The product must be properly applied to work correctly. If you need more information on this product, or if you have a particular problem or question, contact KIDDE-FENWAL, INC., Ashland, MA 01721. Telephone: (508) 881-2000. K-76-606 Rev AB © 2009 Kidde-Fenwal Inc. Printed in USA Kidde Fire Systems A UTC Fire & Security Company 400 Main Street Ashland, MA 01721 Ph: 508.881.2000 Fax: 508.881.8920 www.kiddefiresystems.com Manual Pull Stations Series 3300 01"Kidde Fire Systems A UTC Fire & Security Company Effective: April 2007 K-84-08 FEATURES Exclusive KIDDE5 Design Unique Field Labeling for either Fire Alarm or Suppression Applications Dual Action Operation Single Pole or Double Pole Keylock for Reset DESCRIPTION The Kidde® Conventional SPST and DPST Series 3300 Manual Pull Stations are high quality, non-coded alarm initiating devices. The Manual Pull Stations are con- structed of heavy die-cast aluminum for long life and use an internal toggle switch for reliable operation. The SPST Manual Pull Station provides an Single Pole, Single Throw switch with screw terminal connections for wiring to the Fire Alarm/Suppression Control Unit. The DPST Manual Pull Station provides a Dual Pole, Sin- gle Throw switch with screw terminal connections. One set of contacts must be wired to the Fire Alarm/Suppre- sion Control Unit and the other may be used for local or remote annunciation. These Manual Pull Stations are designed for quick, effi- cient response by personnel in an emergency, while the double action PUSH/PULL levers prevent accidental operation. This unit should use a break rod as an indica- tor of operation. The Manual Pull Stations can be mounted in an indoor or outdoor weatherproof backbox (Model SBG-32S or Model SGB-32C) or a North American 2-1/2 in. (64 mm) deep 1-gang box. The Manual Pull Station terminal block accepts 14, 16 and 18 AWG wire. FIRE ALARM OR SUPPRESSION RELEASE LABELING The Kidde Series 3300 Manual Pull Stations have a unique labeling method which provides the installer the greatest amount of flexibility. Seven labels are shipped with each station: FIRE ALARM • FM-200 RELEASE CO2 RELEASE • FE-13 RELEASE FIRE SYSTEMS • HALON-1301 RELEASE RELEASE NOVEC 1230 RELEASE FM Approved cULus Listed for US and Canada Other domestic approvals in process Surface and Weatherproof Backboxes Backwards compatible mounting with the B-lO and B-Il These permanent, heavy-duty Lexan® self-adhesive labels are die-cut with raised lettering. During installation, the installer simply chooses the appropriate label, removes the protective backing, and places the label into the space on the top of the station. This flexibility allows installations to be customized for each customer, without the expense of having to carry extra inventory. OPERATION The dual action Series 3300 manual stations are oper- ated by simply pushing the PUSH bar inwards, allowing the PULL handle to be grasped in a one-handed motion. The handle is then pulled down as far as it will go. If the optional breakrod is installed, it would break at this point. The handle is now locked in place, and is easily visible from up to 50 feet away. The handle is reset by opening the station with the key and placing the handle in the nor- mal upright position. Place the switch actuator in the SGB-32S INTERIOR SURFACE BA CKB OX Dimensions: 4.75 in. H x 3.25 in. W 2.25 in. D Construction: Steel sheet metal. Conduit: Two knockouts for 1/2 in. conduit connectors, one on top and bottom. Mounting: Mounts to the box with (4) 8/32 screws, which ship with each box. SGB-32C WEATHERPROOF SURFACE BA CKBOX Dimensions: 4.75 in. H x 3.25 in. W x 2.25 in. 0 Construction: Cast aluminum. Conduit: One threaded opening for 1/2 in. conduit connector. Mounting: Mounts to the box with (4) 8/32 screws and a foam gasket, which ship with each box. 1.5lMbi. (27mm) —+ 31132 In. 4-314 In. (121 mm) Jown position, insert breakrod into cavity beneath handle if applicable), and re-lock the station. SPECIFICATIONS Station Type: Double Action, Non-coded Switch Type: P/N 84-330001-001: SPST P/N 84-330001-002: DPST Switch rating: 2 Amp @ 240 Vac or 125 Vdc Operating Tempera- -40°F to 150°F (-40°C to 66°C) ture Range: Operating Humidity 0-95% RH Range: Construction: Die-cast metal housing Compatible Electrical Indoor: Sheet metal Model SGB- Boxes: 32S Outdoor: Weatherproof Die-cast Model SGB-32C Shipping Weight: 1.12 lbs. (510 g) ORDERING INFORMATION Part Number Description 84-330001-001 Double Action Manual Pull Station with SPST Switch - ships with mounting hardware, 2 keys, I break rod, and label set. 84-330001-002 Double Action Manual Pull Station with DPST Switch - ships with mounting hardware, 2 keys, I break rod, and label set 84-100009-001 SGB-32S Indoor Backbox 84-100009-002 SGB-32C Outdoor Waterproof Backbox 84-100008-002 Pkg. of (12) Breakrods 06-118013-001 Spare Key 06-231866-930 Label Set DIMENSIONS (shown with Fire System Release Label installed) Kidde is a registered trademark of Kidde-Fenwal, Inc. FM-200 is a registered trademark of the Greek Lakes Chemical Corporation. 3M and Novec are trademarks of 3M. FE-13 is a trademark of DuPont. Lexan is a registered trademark of the General Electric Company. This literature is provided for informational purposes only. KIDDE-FENWAL, INC. assumes no responsibility for the product's suitability for a particular application. The prod- uct must be properly applied to work correctly. If you need more information on this product, or if you have a particular problem or ques- tion, contact KIDDE-FENWAL, INC., Ashland, MA 01721. Telephone: (508) 881-2000. K-84-08 Rev AA © 2007 Kidde-Fenwal Inc. Printed in USA Iff Kidde Fire Systems A UTC Fire & Security Company 400 Main Street Ashland, MA 01721 Ph: 508.881.2000 Fax: 508.881.8920 www.kiddefiresystems.com Figure 1. Dimension Details Model 878752 Suppression System Abort Station Kidde Fire Systems Effective: November 2014 K-84-1O FEATURES UL Listed Flush or Surface Mount One Normally Open Contact Sized for Double Gang Box DESCRIPTION The Kidde® Model 878752 Abort Station features a large, easy-to-operate abort push button. The momentary type switch is very easy to see due to its highly visible yellow color. The abort station stainless steel faceplate is clearly labeled with operation procedures —eliminating indeci- sion and hesitation. The Backbox is painted with red enamel and is provided with four 1/2-inch knockouts. The pre-drilled and tapped mounting tabs allow for easy attachment of the abort station. To make the Abort Station an addressable SLC device for use with Kidde Intelligent control units, one SmartOne® Model Al monitor module (purchased separately) must be installed into the backbox. The Model Al monitor mod- ule is seated inside a bracket (included) and easily installs with two mounting screws. A cULus-listed Abort Station for Canadian applications that require compliance to ULC S527-11 (3rd edition) is also available (blue faceplate with white raised lettering). Order PIN 84-878752-110. TECHNICAL SPECIFICATIONS Electrical Ratings: One normally open momentary contact, rated 2.5 Amps @ 120 Vdc Ambient Temperature: -13°F to 158°F (-25°C to 70°C) Terminals: Captive screws and saddle clamps accept 14 AWG to 24 AWG wire Mounting: Four 6-32 x 1/2-inch mounting screws included ORDERING INFORMATION Part Number Description Shipping Weight 84-878752-010 Abort Station 2 lb. (0.9 kg) 06-236881-001 Backbox, Red 1 lb. (0.45 kg) Model Al Addressable 5 oz. (145 g) 70-407008-001 Monitor Module, N.O. (includes bracket) Large Yellow Push Button Switch Abort Station Becomes Addressable SLC Device with installation of one (1) Model Al Addressable Monitor Module, N.O. 4-1/2 In. (114 mm) I 4-1/2 in. (114 mm) Q PUSH/ HOLD I fdde 1-11116 In. SUPPRESSION SYSTEM ABORT (43 mm) 3-3164 In. (77 mm) 2 In (51 mnN 44" In. N. 117 mm Kidde Fire Systems 400 Main Street Ashland, MA 01721 Ph: 508.881.2000 Fax: 508.881.8920 wtwkiddeflresystems.com This literature is provided for informational purposes only. KIDDE-FENWAL, INC. assumes no responsibility for the products suitability for a particular application. The product must be properly applied to work correctly. If you need more information on this product, or if you have a particular problem or question, contact KIDDE-FENWAL, INC., Ashland, MA 01721. Telephone: (508) 881-2000. K-84-10 Rev AC 02014 Kidde-Fenwal Inc Effective: June 2007 Series MT Multitone Horns and Series MT Multitone Horn-Strobes F-75..O01 FEATURES E FENWAL Protection Systems A UTC Fire & Security Company Approvals include: UL 1971 and UL 464. Factory Mutual (FM), California State Fire Marshal (CSFM) and New York City (MEA). Designed to meet or exceed ADAINFPAIUFCIANSI Standards and Accessibility Guidelines. Meets OSHA 29 Part 1910,165. One alarm appliance with eight (8) selective signals to provide superior sound penetration for various ambient and wall conditions with two field selectable sound output levels. Audible and strobe can operate from a single signal- ing circuit with any of the eight (8) audible signals. Code-3 Horn and Tone meet ANSIINFPA temporal pat- tern for standard emergency evacuation signaling. Multi-Candela MT Strobe models available with field selectable 151301751110 candela settings. Single Candela MT Strobe models available with IS/ 75 candela rating. Weatherproof MT Strobe models available with 751 180 candela rating. Strobe markings for fire and suppression applica- tions. Wide listed voltage range, filtered (DC) and FWR. Polarized inputs for compatibility with standard reverse polarity type supervision of circuit wiring by an alarm panel. Low cost installation via standard electrical boxes. Attractive flush or surface mounting options. No additional trimplate required for flush mounting. IN and OUT wiring terminations that accept two (2) #12 to #18 AWG wires at each terminal. DESCRIPTION Fenwal Series MT and MT Strobe Multitone electronic signals offer a choice of eight (8) nationally and interna- tionally recognized alerting sounds: Horn, Bell, March Time Horn, Code-3 Tone, Code-3 Horn, Slow Whoop, Siren or Hi/Lo Tone. Our Code-3 horn and tone patterns are engineered to comply with NFPA/ANSI Temporal Pat- tern specifications without requiring additional equip- ment. With MT and MT Strobe Signals, one alarm appliance meets most of your signaling needs. The MT Strobes are designed for ADA applications with maximum performance, reliability and cost-effectiveness while meeting or exceeding the latest requirements of NFPA 72 (1999), ANSI 117.1, UFC (2000) and UL Stan- dard 1971 as well as meeting ADA requirements con- cerning photosensitive epilepsy. Series MT Horn Strobe (with lOB backbox) Each MT and MT Strobe appliance has two user selec- tive sound output levels: STANDARD dBA and HIGH dBA. The MT-12/14 provides dual voltage capability in one unit, 12 Vdc or 24 Vdc operation, filtered or FWR. The MT Strobe Electronic Signals operate with 24 Vdc and may be used with filtered or unfiltered (full-wave-rectified) input voltages. Separate input terminals are available and shunt wires are provided to enable both tone and strobe to operate simultaneously from a single input. The Multitone Strobe Signals are UL Listed for indoor wall mount applications, under Standard 1971 for Devices for the Hearing Impaired and under Standard 464 for Audible Signal Appliances. MT Strobe models are listed for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% ± 2%. The MT-12/24 and MTWP models for outdoor use are Listed for -31°F to 150°F (-35°C to 66°C) and maxi- mum humidity of 95%. The strobe devices use a Xenon flashtube with solid state circuitry enclosed in a rugged Lexan (or equivalent) lens to provide maximum reliability for effective visible signaling. Strobe lens markings avail- able for "Fire" and "Agent" labeled applications. The Series MT Signals have IN and OUT wiring termina- tions that accept two #12 to #18 AWG wires at each ter- minal. Inputs are polarized for compatibility with standard reverse polarity type supervision. Table 1. Alarm Tones Tone Alarm Tones Pattern Description Horn Broadband Horn (Continuous) Bell 1560 Hz Modulated (0.07 sec. ON/Repeat) March Time Horn Horn (0.25 sec. ONI0.25 sec. OFF/Repeat) Code-3 Horn Horn (ANSI S3.41 Temporal Pattern) Code-3 Tone 500 Hz (ANSI S3.41 Temporal Pattern) Slow 500-1200 op Hz SWEEP (4.0 sec. ON/0.5 sec. OFF/Repeat) Siren 600-1200 HZ SWEEP (1.0 sec. ON/Repeat) HI/Lo 1000/800 (025 sec. ON/Alternate) GENERAL NOTES Strobes are designed to flash at I flash per second minimum over their 'Regulated Voltage Range." Note that NFPA-72 (1999) specifies a flash rate of I to 2 flashes per second and ADA Guidelines specifies a flash rate of I to 3 flashes per second. All candela ratings represent minimum effective Mul- titon Strobe intensity based on UL 1971. The MT Audible is UL 464 Listed. Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change, UL used the terminology "Listed Voltage Range." Table 3. Current Ratings for Series MT Strobe Portion Model RMS Current (Amps) MT241575 MTWP2475 MT24MCW Candela 1575cd 180cd 15cd 30cd 75cd llocd 24.0Vdc 0.060 0.094 0.041 0.063 0.109 0.140 UL Max* 0.090 0.138 0.060 0.092 0.185 0.220 * RMS current ratings are per UL aerage RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the madmum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. SPECIFICATIONS Table 2. dBA and Current Ratings for Series MT Audible Portion Tone RMS Current (Amps) dBA@ 10 Ft (UL Reverberant) dA@ 10 Ft 24 VDC 12 VDC 24 VDC 12 VDC 12 and 24 VDC HI Output - STD Output HI Output - - STD Output - HI Output STD Output HI Output STD Output HI Output STD Output @24 VDC UL max* @ 24 VDC UL max" @ 24 VDC UL max" @24 VDC - UL max" Horn 0.074 0.108 0.033 0.044 0.145 0.176 0.023 0.034 92 87 90 77 99 93 Bell 0.040 0.053 0.018 0.024 0.077 0.095 0.014 0.020 86 80 85 69 92 87 March Time Horn 0.067 0.104 0.033 0.038 0.109 0.142 0.023 0.034 89 84 89 74 99 93 Code-3 Horn 0.069 0.091 0.026 0.035 1 0.100 0.142 0.023 0.034 88 83 88 73 99 93 Code-3 Tone 0.061 0.075 0.026 0.035 0.088 0.105 0.015 0.021 85 80 84 70 95 90 Slow Whoop 0.069 0.098 0.028 0.037 0.100 0.142 0.025 0.035 90 89 89 75 99 94 Siren 0.080 0.104 0.027 0.036 0.122 0.152 0.021 0.030 89 84 89 75 98 93 HLILO 0.044 0.057 0.020 0.026 0.089 0.114 0.018 0.026 86 81 86 71 93 88 * RMS current ratings are per UL avorage RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. -2- WIRING DIAGRAMS 3. Contact Fenwal for "Installation Instructions" sheets on these products. These materials contain impor- MT SIGNAL FROM PRECEDING 10 NEW + REPJRECE APPLIANCE. OR FEC P SNUDW ORECLR SIGNAL AUDIBLE SIGNAL AND STROBE OPERATE INDEPENDENTLY FROM PRECEDING + + TO NEXT AUDIBLE - MCP APPLIANCE OR EOLR FROM PRECEDING + ______________________ ______________________ 10 NEXT APPLIANCE, smnm STROEE - OR FACP OR ECLR + STROBE AUDIBLE AUDIBLE SIGNAL AND STROBE OPERATE IN UNISON, RED AND BLACK SHUNT-WIRES ARE SUPPLIED. FROM RED PRECEDING + + 1ONRET APPLIANCE - 4-+--,EOLR APPLIANCE __________ OR - OR FACP STROBE AUDIBLE INSTALLATION NOTES If the strobe and audible operate on the same cir- cuit, add the strobe current from Table 3 to the audi- ble current from Table 2. For Peak and Inrush current across the listed voltage range, refer to Installation Instructions. 2. The average current indicated is per actual Produc- tion Testing at listed Vdc. For rated average and Peak current across the UL listed voltage range for both filtered DC and unfiltered VRMS, see Installa- tion Instructions. Failure to comply with the installation instruction sheets could result in improper A installation, application, and/or operation WARNING of these products in an emergency situa- tion, which could result in property damage and serious injury or death. tant information that should be read prior to specify- ing or installing these products, including: Total current required by all devices connected to system primary and secondary power sources. Fuse ratings on signaling circuits to handle maxi- mum inrush or peak currents from all devices on those circuits. Composite flash rate from multiple strobes within a person's field of view. Installation in office areas and other specification and installation issues. Use strobes only on circuits with continuously applied operating voltage. Do not use strobes on coded or interrupted circuits in which the applied voltage is cycled on and off, as the strobe may not flash. The voltage applied to these products must be within their rated input voltage range. Conductor size (AWG), length and ampacity should be taken into consideration prior to design and installation of these products, particularly in retrofit installations. 4. Fenwal notification appliances must be used within their published specifications and must be PROP- ERLY specified, applied, installed, operated, main- tained and operationally tested in accordance with their installation instructions at the time of installa- tion and at least twice a year or more often and in accordance with local, state and federal codes, reg- ulations and laws. Specification, application, installa- tion, operation, maintenance and testing must be performed by qualified personnel for proper opera- tion in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters' Labo- ratories (UL), National Electrical Code (NEC), Occu- pational Safety and Health Administration (OSHA), local, state, county, province, district, federal and other applicable building and fire standards, guide- lines, regulations, laws and codes including, but not limited to, all appendices and amendments and the requirements of the local Authority Having Jurisdic- tion (AHJ). ARCHITECTS AND ENGINEERS SPECIFICATIONS The notification appliance shall be a Fenwal MT Series audible/visual device or equivalent. Notification appliance shall be electronic and use solid state components. Elec- tromechanical alternatives are not approved. Each elec- tronic signal shall provide eight (8) field selectable alarm tones. The tones shall consist of: HORN, BELL, MARCH TIME HORN, CODE-3 HORN, CODE-3 TONE, SLOW WHOOP, SIREN AND HI/LO. Tone selection shall be by durable dip switch assembly and not clips or jumpers. -3- The Multitone Audible appliance shall be UL Listed under Standard 464 for Audible Signal Appliances. The audible and the strobe shall be able to operate from a single noti- fication circuit while producing any of these tones. The device shall provide two output sound levels: STAN- DARD and HIGH dBA. The HIGH dBA setting shall pro- vide a minimum 5 dBA increase in sound output at nominal voltage. The HIGH anechoic dBA measurement at 10 feet at the alarm HORN SETTING shall be 99 dBA minimum. Operating voltages shall be 24 Vdc using fil- tered power or unfiltered power supply (full-wave-recti- fied). All models shall have provisions for standard reverse polarity type supervision and IN/OUT field wiring using terminals that accept #12 to #18 AWG wiring. Combination audible/visual appliances shall incorporate a Xenon flashtube enclosed in a rugged Lexane lens or equivalent with solid state circuitry. Strobe shall produce a flash rate of one (1) flash per second minimum over the voltage range. The strobe intensity shall be rated per UL and Listed under Standard 1971 for Signaling Devices for the Hearing Impaired for 15/75 cd multi-candela with field selectable 15/30/75/110 candela settings. The 15/75 can- dela strobe shall be specified when 15 candela or with 75 candela intensity on-axis is required. Strobe models shall incorporate circuitry for synchronized strobe flash and shall be designed for compatibility with Fenwal SM and/ or DSM Sync Modules. The strobes shall not drift out of synchronization at any time during operation. If the mod- ule fails to operate (i.e., contacts remain closed), the strobes shall revert to a non-synchronized default flash rate. All Listed strobe appliances shall incorporate low temper- ature compensation to insure the lowest possible current consumption. Strobe activation shall be via independent input or from the same input circuit as the audible. The combination audible/visual appliances may be installed indoors and surface or flush mounted. They shall mount to standard electrical hardware requiring no additional trimplate or adapter. The aesthetic appearance shall not have any mounting holes or screw heads visible when the installation is completed. The appliance shall be finished in a textured red color. The audible device may be installed indoors or outdoors with the proper backbox. For weatherproof applications where specifications require 75 cd at -31°F (-35°C) and full temperature range of -31°F to 150°F, the Fenwal Model MTWP-2475W FR shall be used. ORDERING INFORMATION Model Number Part Number Input Rated Strobe Mounting Voltage Candela Label Options MT-1 2124-R 75-000010.001 12/24 - - B,H,U,K 15 MT-241575W-FR 75-000015-001 24 (75 FIRE B,H,J,K on AXE) 15 MT-241575W-AR 75-000015-002 24 (75 AGENT B,H,I,J,K on AXE) MT-24MCW-FR 75-000018-001 24 15/30/75! FIRE B,H,U,K 110 MT-24MCW-AR 75-000018-002 24 15130/75/ AGENT B,H,I,J,K 110 180 t M11NP-2475W-FR 75-000017.001 24 77°F FIRE H (25°C) __ Notes: MT-12/24 Audible can be used with Fenwal's RSSP Multi-Candela for applications requiring 15, 30, 75, 110 cd Wall Strobes. MTWP-2475W is weatherproof and rated for 180 cd @ 77°F (25°C) and 75 cd @ -31°F (-35°C) with low current draw. SM Sync Modules are rated for 3.0 amperes at 12/ 24 Vdc; DSM Dual Circuit Modules are rated for 3.0 amperes per circuit. Maximum number of intercon- nected DSM modules is twenty (20). Refer to Data Sheet 75-12. Use MT-241575W when 15 cd is specified. 15/75 is UL Listed for 15 cd with 75 cd on AXIS. MOUNTING OPTIONS Model Number Part Number Mounting Options DBB-R 75-000000.009 A lSP-R 75-000000-002 B WBB-R 75-000000-008 E IOB-R 75-000000-001 H RP-R 75-000000-003 J For complete installation options, refer to the Alarm Sig- nals Installation Data Sheet 75-008.A. Fenwal is a registered trademark of Kidde-Fenwal, Inc. Lexan is a registered trademark of the General Electric Company. I This literature is provided for informational purposes only. KIDDE-FENWAL, INC. I NFENWAL I assumes no responsibility for the product's suitability for a particular application. The I I product must be propelly applied to work correctly. I Protection Systems If you need more information on this product, or if you have a particular problem or ques- A UTC Fire & Security Company ton, contact KIDDE-FENWAL INC., Ashland, MA 01721. Telephone: (508) 881-2000. I 400 Main Street Ashland. MA 01721 Ph: 508.881.2000 F-75-001 Rev AS ID 2007 Kidde-Fenwal Inc. Printed in USA Fax: 508.881.8920 www.Fenwalfire.com SYSTEM SENSOR® Indoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications SpectrAlert® Advance audible visible notification products are rich with features guaranteed to cut installation times and maximize profits. Features Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela Field-selectable candela settings on wall units: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and three volume selections Universal mounting plate for wall units Mounting plate shorting spring checks wiring continuity before device installation Electrically Compatible with legacy SpectrAlert devices Compatible with MDL3 sync module Listed for ceiling or wall mounting SY S O. The SpectrAlert Advance series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE-printed devices, SpectrAlert Advance can meet virtually any application requirement. Like the entire SpectrAlert Advance product line, wall-mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, SpectrAlert Advance utilizes a universal mounting plate with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with three volume selections. Aaencv Listinas SIGNALIIG ®<3>MEA LISTED APPROVED approved 7125-1653:186 (indoor strobes) 7125-1653:188 (horn strobes, S6011 (chimes, horn strobes, horns) 3523572 MEA452-05-E chime strobes) S5512 (strobes) 7135-1653:189 (horns, chimes) SpectrAlert Advance Specifications General SpectrAlert Advance horns, strobes, and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double-gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the SyncoCircuitTM Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts: 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full- wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110,115, 135,150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model ______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model ______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync.Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) InputTerminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions (including lens) 5.6'L x 4.7"W x 2.5D (142 mm Lx 119 mm W x 64 mm 0) Horn Dimensions 5.6"L x 4.7W x 1.3D (142 mm Lx 119 mm x 33 mm D) Wall-Mount Trim Ring Dimensions (sold as a 5 pack) (TR-HS) 5.7"L x 4.8W x 0.35"D (145 mm Lx 122 mm W x 9 m D) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. P, 5, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. UL Current Draw Data tuJ 1flji1lIThJI7ITI1 Candela 8-17.5 Volts DC FWR 16-33 Volts DC FWR It _____ Morn _Current Sound Pattern dB Draw ___________________________ 8-17.5 Volts DC FWR 16-33 Volts DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15175 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-temporal High 57 56 69 75 95 NA NA 181 176 Non-temporal Medium 42 50 60 69 110 NA NA 202 195 Non-temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 UL Max. Current Draw (mA RMS), 2 -Wire Horn Strobe, Standard Candela Range (15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 PAIR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low tuJU Max. Current IDraw( WAl:lAFiWaWTT1Horn Strobe,Candela1: 132 154 80 90 105 III.1lI 161 184 202 211 DC Input 16-33 Volts 135 150 177 185 FWR Input 16-33 Volts 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Horn Tones and Sound Output Data Horn and Horn Strobe Output (dBA) 8-17.5 Switch Volts Position Sound Pattern dB DC FWR 16-33 Volts DC FWR 24-Volt Nominal Reverberant Anechoic DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 75 75 80 80 86 86 96 96 3 Temporal Low 71 71 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 73 74 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 74 75 81 81 88 85 96 92 tSethngs 7, 8, and 9 are not available on 2-wire horn strobes. SpectrAlert Advance Dimensions Ti Wall-mount horn strobes SpectrAlert Advance Ordering Information Wall Horn Strobes Wall Strobes (cont.) P2R 2-Wire Horn Strobe, Standard Cd, Red SRH Strobe, High cd, Red P2R-P 2-Wire Horn Strobe, Standard cd, Red, Plain SRH-P Strobe, High cd, Red, Plain P2R-SP 2-Wire Horn Strobe, Standard cd, Red, "FUEGO" SRH-SP Strobe, High cd, Red, "FUEGO" P2RH 2-Wire Horn Strobe, High cd, Red SW Strobe, Standard cd, White P2RH-P 2-Wire Horn Strobe, High cd, Red, Plain SW-P Strobe, Standard cd, White, Plain P2W 2-Wire Horn Strobe, Standard cd, White SWH Strobe, High cd, White P2W-P 2-Wire Horn Strobe, Standard cd, White, Plain SWH-P Strobe, High cd, White, Plain P2WH 2-Wire Horn Strobe, High cd, White Horns P2WH-P 2-Wire Horn Strobe, High cd, White, Plain HR Horn, Red P4R 4-Wire Horn Strobe, Standard cd, Red HW Horn, White P4R-P 4-Wire Horn Strobe, Standard cd, Red, Plain Accessories P4RH 4-Wire Horn Strobe, High cd, Red TR-HS Trim Ring, Wall, Red P4W 4-Wire Horn Strobe, Standard cd, White SBBR Indoor Surface Mount Back Box, Red Wall Strobes SBBW Indoor Surface Mount Back Box, White SR Strobe, Standard cd, Red SR-P Strobe, Standard cd, Red, Plain SR-SP Strobe, Standard cd, Red, "FUEGO" Notes: All-P models have a plain housing (no "FIRE" marking on Cover) All -SP models have "FUEGO" marking on cover "Standard cd" refers to strobes that include 15, 15/75,30,75,95, 110, and 115 candela settings. "High cd" refers to strobes that include 135, 150, 177, and 185 candela settings. Y.54 TEM 3825 Ohio Avenue • St. Charles, IL 60174 02014 System Sensor. for current product information, including the latest version of this data sheet SENSOR' Phone: 800 • Fax: 630-377-6495 Product specifications subject to change Without notice. Visit SyStemse555r.Com www.systemsensor.Com AVDS10201 • 1114 FM-200® Component Description fKidde Fire Systems Warning Nameplate (FM-200) A UTC Fire & Security Company Effective: April 2007 K-90-9030 FEATURES For Use with UL Listed, ULC Listed and • See Kidde Manual 90-FM200M-021 for FMApproved Systems USCG Approval P/N: 06.231865-139 10.000 0.063 [ 0.340 9.360 - 0.340 f ó WARNING ó THIS AREA IS PROTECTED BY A 0.062 FM-200 EXTINGUISHING 5.000 4.360 SYSTEM. DO NOT ENTER WITHOUT AUTHORIZATION DURING OR AFTER DISCHARGE 0.281 .005 DIA. TYP. 4 HOLES MATERIALS Aluminum Type 1100—H14, 0.032 :L 0.003 Thick. All Let- ters to be 48 pt., Alternate Gothic #2, Etched 0.003 to 0.005 and Filled in With Red Chip Proof Enamel Color No. 21105 per Fed. Stc. 595 Finish: One Coat Clear Lacquer Both Sides FM-200 is a registered trademark of the Great Lakes chemical Corporation. This literature is provided for informational purposes only. KIDDE-FENWAL INC. assumes Kidde Fire Systems no responsibility for the producf a suitability for a particular application. The product must be A UTC Fire & Security Company properly applied to work correctly. 400 Main Street If you need more Information on this product, or if you have a particular problem or question. Ashland MA 01721 contact KIDDE-FENWAL, INC., Ashland, MA 01721. Telephone: (508) 881-2000. Ph: 508:861.2000 K-90-9030 Rev AB 02007 Kidde-Fenwal Inc. Printed In USA Fax: 508.881.8920 www.kiddefiresystems.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-1076:0189 Page 1 of I CATEGORY: 7165 - FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: KIDDE-FENWAL, INC400 Main Street, Ashland, MA 01721 Contact: Terrill Garland (508) 881-2000 Fax (508) 881-1773 Email: terrill.garland@kidde-fenwal.com DESIGN: Kidde Fire Systems Model AEGIS fire alarm control unit. Automatic, manual, local, central station, protected premises, waterfiow, sprinkler supervisory and releasing device services. Refer to the listee's data sheet for detailed product description and operational considerations. RATING: Primary: 120/240 VAC, Standby: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and FM label. APPROVAL: Listed as a fire alarm control unit for use with listee's separately listed electrically and functionally compatible initiating and indicating devices. Refer to listee's Installation instruction Manual for details. Control unit meets the requirements of the 9th Edition of ANSI/UL 864. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. 0418-2007 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed \ the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct V operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL LISTING SERVICE FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM tp LISTING No. 7272-1076:0187 Page 1 of I CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: KIDDE-FENWAL, INC400 Main Street, Ashland, MA 01721 Contact: Terrill Garland (508) 881-2000 Fax (508) 881-1773 Email: temll.garland©kidde-fenwal.com DESIGN: Models PSD-7157 and PSD-7157D photoelectric type smoke detectors. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 10.2 -36.8 VDC normal, 24 VDC alarm INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as a photoelectric smoke detector for use with listee's 2-WIRE, 2WRLT, 2WRB, 4WRB or MA-001 bases (CSFM Listing No. 7300-1076:116) and separately listed compatible control units. Model PSD-7157 for open area protection between 0 and 300 fpm and Model PSD-71 57D for open area protection between 0 and 4000 fpm. Suitable for releasing device service when using Models 2WRB, 4WRB bases, and Mechanical Adapter base Model MA-001. NOTE: 12-02-2005jw * This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1076:0116 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNITACCESSORIES/MISC. DEVICES LISTEE: KIDDE-FENWAL, INC400 Main Street, Ashland, MA 01721 Contact: Terrill Garland (508) 881-2000 Fax (508) 881-1773 Email: terrilLgarlandkidde-fenwal.com DESIGN: Models 2-WIRE, 2WRLT, 2WRB, 4WRB, 4SB, 6SB smoke detector bases, Model ASM-6SB (70-200200-002) addressable signal sounder module with base and Models MA-001 and MA-002 smoke detector adapters. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 10.2 - 36.8 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating and UL label. APPROVAL: Models 2-WIRE, 2WRLT, 2WRB, 4WRB are listed as smoke detector bases and Model MA-001 is listed as a smoke detector adapter for use with Models CPD-7051 (CSFM Listing No. 7271-1076:115), PSD-7155 or PSD-7156 (CSFM Listing No. 7272-1076:117) smoke detector heads and separately listed compatible fire alarm control units. Models 2WRLT, 2WRB, 4WRB, 4SB and 6SB are also suitable for duct applications when used with Model RCM500 remote test/LED. Models 2WRB and 4WRB are suitable for releasing device service. Models 4SB, 6SB are listed as smoke detector bases and Model MA-002 is listed as a smoke detector adapter for use with listee's separately listed *compatible fire alarm control units. Model ASM-6SB is listed as a smoke detector base with addressable signal sounder module for use with detector Models PSD-7 152 (CSFM Listing No. 7272-1076 *Rev. 03-21-08 mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION IN OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-1076:0147 Page 1 of I CATEGORY: 7150— FIRE ALARM PULL BOXES LISTEE: KIDDE-FENWAL, INC400 Main Street, Ashland, MA 01721 Contact: Terrill Garland (508) 881-2000 Fax (508) 881-1773 Email: terrill.garlandckidde-fenwal.com DESIGN: Models BIO and 1311, 30195000002*, 30195000004*, 30-330001-001, 30-330001-002, 84-330001-001 and 84-330001-002 key lock, push bar, noncoded manual pull stations; Models 30195000001* and 30195000003* key lock, no push bar, noncoded manual pull stations. Suitable for outdoor use when installed with Model SGB-32C back box. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 30VDC INSTALLATION: In accordance with listee's printed installation, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as manual pull stations for use with separately listed and compatible fire alarm control units. * Only Models 30-195000-001, -002, -003, and -004 manual pull boxes meet the requirements of UL Standard 38, 1999 Edition with California amendments. XLF: 7150-1408:0107 *Update 06-22-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed p\ the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1076:0120 Page 1 of I CATEGORY: 7300 - FIRE ALARM CONTROL UNITACCESSORIES/MISC. DEVICES LISTEE: KIDDE-FENWAL, INC400 Main Street, Ashland, MA 01721 Contact: Terrill Garland (508) 881-2000 Fax (508) 881-1773 Email: temII.garIandkidde-fenwaI.com DESIGN: Models PIN 30-232001-001 front panel w/cutout for audible and PIN 30-232001-002 front panel wlo cutout for audible. These units have a manual release switch and abort switch. Models 878752-011-02, 30-193000-0011-002 abort stations. Models 296105, 30-193000-003 back boxes. Models 30-322003-003, 84.322003-003 Remote Display Unit Backbox. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. For indoor use only. MARKING: Listees name, model number, and UL label. APPROVAL: Models 30-232001-001 and 30-232001-002 are listed as control unit accessories when used in conjunction with listees' separately listed fire alarm control units. Models 878752-01/-02, 30-193000-001/-002 abort stations and Models 296105, 30-193000-003 back boxes are intended for use with listed releasing device control units. *Rev. 06-21-2003 BH This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:0155 Page 1 of I CATEGORY: 7125— FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Cooper Wheelock Inc.7246 16th St. E., Ste. 105, Sarasota, FL 34243 Contact: Tom Conover (941) 487-2336 Email: thomas.conover@cooperindustries.com DESIGN: Models MT Multitone Sync *hom/stros Models may be followed by 12 or 24 for voltage, followed by strobe/candela rating, followed by W for wall mount. Units may be followed by suffixes to designate lens lettering and plate color. The series can provide one of eight tone outputs. Model MT-24MCW, may be followed by a letter indicating enclosure color. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 12 voltage: 8-17.5 VDC 24 voltage: 16-33 VDC Flash rate: 60 flashes/mm Candela: Models 1575: 15cd (75cd on axis) Models 75:75cd Models MCW: 15cd, 30cd, 75cd or 110cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. For wall mount only. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as *hornlstrobes suitable for the hearing impaired when used in conjunction with separately listed electrically compatible fire alarm control units. For indoor use only.For synchronized strobes, Models SM-12/24, or DSM-12/24 Sync Module (CSFM Listing No. 7300-0785:132) must be used. Refer to manufacturer's Installation Manual for details. These units can produce a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. *Rev. 05.25-10 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL LISTING SERVICE FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM (9 LISTING No. 7125-1653:0186 Page 1 of I CATEGORY: 7125 - FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Intl lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.linhart@systemsensor.com DESIGN: Synchronous type strobe lights, Models SR, SRH, SW, SW-CLR-ALERT, SWH, SCR, SCRH, SCW, SCW-CLR-ALERT and SCWH followed by the suffix -P, -SP, -PG, or none. Intended for indoor use mounted on the wall or the ceiling. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 8-17.5 or 16-33 VDC/FWR Candela: 15,15f75, 30, 75, 95, 110, 115, *135, *150, *177 *185cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as strobe lights suitable for hearing impaired application when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Refer to listee's Installation Instruction Manual for details. *Rev. 03-11.10 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division