7030 AVENIDA ENCINAS; 100; FPC2019-0134
PERMIT REPORT (ity of Carlsbad Print Date: 09/28/2023 Job Address: 7030 AVENIDA ENCINAS, # 100, CARLSBAD, CA 92011-4600 Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2144301400 Track #: Valuation: $186,040.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Permit No: FPC2019-0134 Status: Closed - Finaled Applied: 06/11/2019 Issued: 06/18/2019 Finaled Close Out: 08/20/2019 Final Inspection: INSPECTOR: Salcedo, Felix Project Title: Description: SPECTRUM - NEW FIRE ALARM FPContractor: TRL SYSTEMS 9155 BROWN DEER RD, # STE 7 SAN DIEGO, CA 92121-2260 (619) 857-8122 FEE AMOUNT FIRE New Alarm System $1,265.00 Total Fees: $1,265.00 Total Payments To Date: $1,265.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1442-389-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov FDNY COA 6227 A 7165-1657: 0244 S3000 Features Auto-programming speeds installation time Supports Signature Series intelligent modules and detectors Combines the Signature intelligent releasing module with Signature multisensor detectors for reliable fire suppression Form C contacts for alarm and trouble, Form A for supervisory Electronic addressing with automatic device mapping Optional Ethernet port for diagnostics, programming and a variety of system reports Two programmable switches with LEDs and custom labeling Supports Genesis horn silence over two wires, and UL 1971-compliant strobe synchronization Class B or Class A wiring Ground fault detection by module Supports up to eight serial annunciators, (LCD, LED-only, and graphic interface) Can use existing wiring for most retrofit applications Upload/download remotely or locally Two-level maintenance alert reporting.. Pre-alarm and alarm verification by point Adjustable detector sensitivity 4 x 20 character backlit LCD display Optional earthquake hardening: seismic Importance Factor 1.5 Standalone operation Transmission test frequency by hour .> Small Building Fire alarm Solutions United Technologies ( -I Intelligent Fire Alarm Systems 064, i01000 Overview EDWARDS brand intelligent life safety systems offer the power of high-end intelligent processing in configurations that deliver uncomplicated solutions for small to mid-sized applications. With intelligent detection, electronic addressing, automatic device mapping, optional Ethernet® connectivity, and a full line of easily- configured option cards and modules, these flexible systems offer versatility that benefits building owners and contractors alike. The 1064 provides one Class A or Class B intelligent device loop that supports up to 64 device addresses, and two Class B Notifi- cation Appliance Circuits (NACs). Optional Class A device wiring is available with the use of a module. The 101000 provides one Class A or Class B intelligent device loop that supports up to 250 device addresses. Loop controller modules may be added in combination to expand total system capacity in 250-point increments to up to 1,000 device addresses. The iOl 000 panel includes four NACs that may be wired for either Class A or Class B operation. The RZI16-2 module adds even more capacity to iO installations by adding up to 16 conventional device circuits and two additional notification appliance circuits. This makes them an ideal retrofit solution that can accommodate new intelligent detectors, as well as existing conventional devices. iO Series supports a wide range of high-end features, including: Signature Series intelligent modules, detectors, and bases R-Series remote annunciators SIGA-REL Releasing Modules I • Fully integrated CO detection using Signature Series detec- [ • tors with or without audible signaling Page 1 018 E E85001-0135 1 Issue 1.1 Application EDWARDS iO Series life safety systems are powerful intelligent solu- tions for small to mid-sized buildings. Advanced intelligent technol- ogy delivers the benefits of flexible system installation, while clean and easy-to-operate user interfaces make panel operation and system maintenance quick and intuitive. The smart choice Signature Series electronic addressing eliminates the tedium of setting dipswitches, and automatic device mapping ensures that each device resides on the system at its correct location. Mean- while, innovative programming allows the designer to customize the system to precisely suit the needs of the building owner. Reliability you can count on The inherent fault-tolerant characteristics of Analog/Addressable Technology boosts the reliability of EDWARDS fire alarm systems. When combined with iO Series smoke and heat detectors, these systems deliver a level of dependability not previously available for small to mid-sized applications. All EDWARDS systems are built to exacting reliability benchmarks and meet international standards for quality, in addition to agency listings for dependability. Clear-cut remote annunciation Remote annunciation is a strong suit of the i0 Series fire alarm systems. Up to eight annunciators can be installed on a single system. Compatible annunciators include a range of LED and LCD models that provide zone or point annunciation, as well as com- mon control capabilities. iO control panels also supports graphic annunciation with optional RA Graphic Annunciator interface mod- ules. Each interface provides common control and 32 LEDs. Programming and remote diagnostics EDWARDS iO Series life safety systems are simple to set up, yet offer advanced programming features that put these small building panels into a class of their own. The auto programming feature quickly gets the panel operational using factory default settings. Basic zone and point settings can be programmed through the front panel interface, so the system is up and running in no time. For more advanced system configuration and correlation groups programming, iO Series systems interface to a PC running com- patible iO-CU software. This option offers full system configuration in the familiar Windows® operating environment. Connection is made to a laptop through the panel's optional RS-232 communi- cations port, which can also be used to connect a system printer. Among the many innovative features of iO Series control panels is the optional network card. This module provides a standard 10/100 Base T Ethernet® network connection that permits access to the control panel from any remote location with the correct communications protocols. The connection can be used to download to the panel from the iO-CU, or upload and view system reports using the iO-CU. Available system reports include: Correlation groups Device details Device maintenance History Internal status System configuration System status Walk test Dialer CO runtime Flexibility built right in Two fully-programmable front panel switch/LED combinations pro- vide an added measure of flexibility. Their slide-in labels take the mystery out of custom applications, and present a clean finished appearance. Perfect for retrofits EDWARDS iO Series control panels are particularly well-suited to retrofit applications. All connections are made over standard wiring - no shielded cable required. This means that in most situations existing wiring can be used to upgrade a legacy control panel to iO technology without the expense or disruption of rewiring the en- tire building. iO control panels also support the ingenious RZI1 6-2 Zone Module, which adds up to 16 conventional circuits and two NACs. This combination easily accommodates new intelligent detection alongside existing conventional circuits, making it an superior solution in the retrofit market. Signals with a difference iO system NACs are configurable to fully support the advanced signaling technology of EDWARDS Genesis and Enhanced Integ- rity notification appliances. These devices offer precision synchro- nization of strobes to UL 1971 standards. For Genesis devices, enabling this feature allows horns to be silenced while strobes on the same two-wire circuit continue to flash until the panel is reset. A complete line of accessories iO Series life safety systems are supported by a complete line of analog/addressable detectors, modules and related equipment. Consult the Ordering Information section for details. Dimensions (21 (3) (4) 10 I!LO Surface Mounting Holes (3) Backbox with Door Attached Semi-flush mounting Holes (4) Backbox with door and trim kit attached. Panel dimensions, in (cm) Model D1 I D3 D4 I D5 D6 D7 I D8 I 09 000 28.0 I 3.85 I 9.0 22.0 15.75 28.2 I 2.7 (71.1) I (9.8) I (22.8) (55.8) I (400) (26.0) 10.25E4.4 1 I (71.6) I (6.8) 1064 21.5 3.85 7.5 I 15.5 14.25 10.25 21.7 I 2.7 (54.6) (9.8) (19.0) (39.4) (36.2) 126.0) I (55.1) (6.8) Add 1-1/2/n. (3.81 cm) to Dl and D5 dimensions for trim kit. The trim kit provides 0.75 inches (1.9 cm) of trim to the top, bottom, and sides of the backbox. 14-024I 0. Page 2of8 . . E85001-0135 Issue 1.1 System Layout iOl 000 Any combination of two single- or dual Signature loop modules --------------------------------------------------------------------- Standard Loop: 250 points (one expansion slot) IO-SDC2 Expander, Loop 1 of 2: 250 points (one expansion slot) ----------------------------------------------------------- w-t - ---cr- - LSOC1 Expander Loop: 250 points (one expansion slot) IO-SDC2 Expander, Loop 2 of 2: 250 points 999 feet-of wiring per!99P---------------------------------- - Ethernet (SA-ETH) DACT/Dialer (SA-DACT) RS-232 (SA-232) Sixteen Conventional lDCs, two additional NACs with RZI1 6-2 module Each iOl000 panel has room for up to two Signature loop control- ler modules in any combination of single or dual 250-device loops. 101000 loops support 125 detectors and 125 modules. Panel Layout 1064 Loop supports up to 64 intelligent devices of any type. Up to 20,000 feet of wiring. Class m = a " I Two wo Bortwo optional Class A NACs e 00 0 A or 6.5 A Booster Power Supply Up to eight remote annunciators FfF s_I Ethernet (SA-ETH) DACT/Dialer (SA-DACT) RS-232 (SA-232) Relays: Two Form C, one Form A Each i064 panel ships with one Signature loop controller that sup- ports 64 devices of any type. This panel's device capacity cannot be expanded. 1 Transformer 2 Main AC wiring block & fuse holder 3 RS-232 card connector (J3) 4 Dialer card connection (J8) 5 Ethernet card connector (J1) 6 Main circuit board 7 Panel backbox enclosure 8 Operator interface 9 SLC card connector (J7) 10 Class A card connector (J2) 11 Tie wrap mounts 12 LED expander connector (J6) 13 Standby batteries Page 3 of 8 E85001-0135 7 ) . Issue 1.1 Wiring & Configuration Signature device loop The system provides one Signature device loop circuit with a total capacity of 125 detectors and 125 module addresses. The loop circuit is supervised for opens, shorts, and grounds. Circuit i01000 1064 specifications Device loops One Class B or A One Class B or A loop, loop, supporting 125 supporting 64 devices of detectors and 125 any kind. modules. Expandable to four loops. Communication Maximum 20 V peak-to-peak line voltage Circuit current - 0.5 A max Circuit 660 total, 0.5 pF, max impedance Isolators 64 maximum Signal Supported on a system-wide basis (all device loops) Synchronization when using a SIGA-CC1 S or SlGA-MCC1 S module and Genesis or Enhanced Integrity notification ap- pliances. Clans A wiring ri SLC B Loop a I device device Data Line Notification appliance circuits (TB2) 101000 control panels come equipped with four notification ap- pliance circuits. i064 control panels come with two NACs. Each circuit can be individually configured for continuous, temporal, synchronized, and coded output. Specifications 101000 1064 Circuit Type 4 Class B or 2 Class A 2 Class B or 2 Class A with SA-CLA module Voltage 24VFWR Current 6.0 A total, 2.5 A max. 3.75 A total, 2.5 A max. per circuit at 120/230 per circuit at 120/230 VAC 60 Hz. VAC 60 Hz. 5.0 A total, 2.5 A max. 3.0 A total, 2.5 A max. per circuit at 230 VAC per circuit at 230 VAC 50 Hz. 50 Hz. Impedance 26 0 total, 0.35 pF max EOLR 15K0,1hW Synchronization Supported system-wide Auxiliary & smoke power outputs (TB3) The control panel provides two auxiliary power outputs that can be used for powering ancillary NO equipment such as remote annunciators and two (1) wire smoke detectors. Aux 2 can be software — NC selected to operate continuously. The circuit is 0 supervised for shorts and grounds. 0 __ (2)— NO Circuit specifications 0 Circuit voltage 21.9 to 28.3 V range R NC Resettable circuit 24 VDC nominal at 500 mA (3) (Aux power 2) NO Continuous circuit 24 VDC nominal at 500 mA. (Aux power 1) Use this circuit for powering 0 two-wire smoke detectors. (4) — Note: Any current above 0.5 amp connected to both Aux — 1 and 2 will reduce the total available NAG power by that 0 amount. - (1) Trouble Alarm, trouble, and supervisory relay (TB3) (2) Supervisory The trouble relay is normally-open, held closed, (3) A1Ifl and opens on any trouble event or when the panel is de-energized. The supervisory relay is (4) Smoke/Aux normally-open, and closes on any supervisory event. The alarm relay changes over on any alarm event. Relay specifications Alarm Trouble Supervisory Type Form C Form A Voltage 24 VDC at 1 A resistive I 24 VDC at 1 A resistive Relay circuits can only be connected to power-limited sources. Annunciator loop (TB4) The control panel provides a connection for up to eight serially driven and supervised remote annunciators. Circuit specifications Device loops Class B (Style Y) or Class A (Style Z) Circuit voltage 2.55 V Circuit current 30 mA max Circuit Up to 8 annunciators or 4000 feet impedance Class B Class A Channel Channel Channel Channel +—+— +—+— TB4 Class B wiring SLC B , (s) :5~ Loop Loop card donato device Class B wiring Class A wiring OUR DLR CHI (+) IN CHI IN CH2 (+) IN CH2 (-I IN CHI (+) IN CHI (-) IN CH2 IN CH2 (-) IN Marking indicates output signal polarity when the circuit is active. Polarity reverses when the circuit is not active. Wire notification appliances accordingly. Notification appliance polarity shown in active state. Page 4 of 8 ;. E85001-0135 3. 1 Issue 1.1 Option Cards EDWARDS iO Series panels are supported by a complete line of modules and related equipment that enhance performance and extend system capabilities. Option cards plug directly into the control panel main circuit board or are connected to it with a ribbon cable. After installation, terminals remain accessible. The cabinet provides ample room for wire routing, keeping wiring neat at all times. Single and Dual Loop Controller Cards The iO-SDC1 is a single loop controller card that can be used with the 064 as a replacement for the standard 64-point loop, or with the iOl 000 as a 250-point expansion module. The iO-SDC2 is a 500-point dual loop controller card for the iOl 000 that provides two SLC circuits, each with 125 detector addresses and 125 module addresses. Specifications 10-SDC1 10-SDC2 Device Addresses iOl 000: one loop, 250 device addresses i064:_64 addresses iOl000: two loops, 500 device addresses Wiring Class B or Class A Operating Voltage 24 VDC Operating Current (fully loaded loop) Standby: 55 mA Alarm: 80 mA Standby: 45 mA Alarm: 70 mA Note: These ratings do not include the use of two-wire smoke modules. Communication Line Max. 20,6 V peak-to-peak Voltage Terminal Rating 12 to 18 AWG (0.75 to 2.5 mm2) Circuit Current 0.5 A max. Max total loop 66 C) resistance Max total loop 0.5 tiF capacitance Isolators 64 isolators maximum per loop (total both isolator bases and modules) Ground Fault 0t05kC) Impedance Operating 32 to 120°F (0 to 49°C) Environment 0 to 93% noncondensing at 90°F (32°C) SA-ETH Ethernet Interface Card SA-ETH wiring To network The SA-ETH card provides a connection standard 10/100 Base T Ether- net network connection for Network cable connecting to an intranet, a local network, or the Internet. The I I card can be used to download I configuration programming from 113 I the iO-CU to the panel. I ft • I The Ethernet card is installed on the plastic assembly and con- Ethernet cam - nects to the main circuit board via a ribbon cable. SA-ETH specifications Ethernet 10/100 Base I Operating environment Temperature 32 to 120°F (0 to 49°C) Humidity 0 to 93% RH, noncondensing at 90°F (32°C) RZ116-2 Remote Zone Interface Module c -- I :1I ii rr The RZ116-2 Addressable Remote Zone Interface Module is an addressable device that provides connections for sixteen Class B Initiating Device Circuits and two Class B Supervised Output Circuits. The inputs and outputs can be configured individually for several device types. It requires 18 consecutive addresses on the Signaling Line Circuit (SLC). Addresses are assigned electronically. There are no address switches to set. The RZI1 6-2 incorporates two 8-segment DIP switches that are used to select the Alarm or Supervisory default device type for each of the 16 IDC circuits. The module also includes one 4-seg- ment DIP switch used to select the default Relay or NAC output device type. Device types other than the default are accomplished through programming. RZI16-2 Specifications Voltage 24V/Aux nominal: 24 VDC Supervisory current: 250 mA at 24 VDC nominal Alarm Current 1000 mA 24V/Aux minimum: 18.4 VDC 24V/Aux maximum: 26.4 VDC NAC1, NAC2 nominal: 24 VDC Current Standby current for 4.7 k EOL (U.S.) 4.8 mA/ circuit Standby current for 3.9 k EOL (Canada) 5.7 mA/ circuit Alarm current at nominal voltage 31.1 mA/ circuit Relay outputs Quantity 2 Type Rating (pilot duty) Programmable 24 VDC at 2.5 A Input circuit wiring 25 0 per wire resistance Initiating device circuits Quantity 16 EOL resistor 4.7 kc) (U.S.); 3.9 kO Canada Zone voltage 22.78 V for 4.7 kC) (U.S.) 22.08 V for 3.9 kO (Canada) Alarm current 31.1 mA' channel at nominal voltage Alarm impedance range <680 0 Trouble impedance range >5.55 IcC) Supervised output circuits EOL resistor 15 kO Quantity 2 Short circuit detection <2.6 kO Open circuit detection > 61.9 kO Contact ratings 24 VDC at 2.5 A (5 A for two NACs) Compatible cabinets MFC(A), iO1 000, APS Page 5 of 8 E85001-0135 Issue 1.1 SA-DACT Dialer The SA-DACT provides communications between the control panel and the central station over a telephone line system. It transmits system status changes (events) to a compatible digital alarm communicator receiver over the public switched telephone network. The dialer is capable of single, dual, or split reporting of events to two different account and telephone numbers. The modem feature of the SA-DACT can also be used for uploading and downloading panel configuration, history, and current status to a PC running the iO-CU. SA-DACT 1 Phone line2 wiring To wall RJ31 jacks Phone line 1 phone jack Phone cables (supplied) kiI 1i]- The dialer phone lines connect to connectors on the dialer's main circuit board. Phone line 1 connects to connector J4 and phone line 2 connects to connector Ji. The SA-DACT queues mes- sages and transmits them based on priority (alarm, supervisory, trouble, and monitor). Activations are transmitted before restora- tions. The SA-DACT is installed on the plastic assembly and connects to the main circuit board via a ribbon cable. SA-DACT specifications Phone line type One or two loop-start lines on a public, switched network Phone line connector RJ-31/38X (C31/38)) Communication formats Contact ID (SIA DC-05) Operating environment Temperature 32 to 120°F (0 to 49°C) Humidity 0 to 93% RH, noncondensing at 90°F (32°C) Compatible DACRs Receiver Models Formats Ademco 685 Contact ID FBII CP220 Contact ID Osborne-Hoffman OH 2000 Contact ID Pnh nRRnn rr,t,,'f lI) SA-232 RS-232 interface The SA-232 card provides an RS-232 in- SA-232 wiring __ terface with iO panels. It can be used for ____ I GND (black wire) connecting a printer to the control panel TXD (white wire) RXD (red wire) to print system events. The card also can be used for connecting a computer to download a configuration program from the 10-CU to the control panel. The RS-232 card is installed on the plas- tic assembly and connects to the main circuit board via a ribbon cable. SA-232 specifications Operating voltage Standard ElA-232 Terminal rating 12 tol8 AWG (0.75 to 2.5 sq mm) Operating environment Temperature 32 to 120°F (0 to 49°C) Humidity 0 to 93% RH, noncondensing at 90°F (32°C) SA-CLA Class A Module (i064 only) The SA-CLA card provides Class A capability for NAC wiring. Its terminal block provides the wiring connection for NAC return wiring. The card is required for annunciator Class A wiring even though this wiring does not return to the SA-CLA card. The SA- CLA is compatible with i064 control panels only. iOl 000 panels are Class A Ready. The SA-CLA is installed directly to the control panel circuit board using its plastic standoffs and plug connection. SA-CLA specifications Operating voltage 24 VFWR Operating current 3.75 A FWR total at 120/230 VAC 60 Hz 3.0 A FWR total at 230 VAC 50 Hz 2.5 A max per circuit Circuit impedance 26 ohms, 0.35uF Terminal rating 12 tol8 AWG (0.75 to 2.5 sq mm) Operating environment Temperature 32 to 120°F (0 to 49°C) Humidity 0 to 93% RH, noncondensing at 90°F (32°C) DI6L-iO LED Display Expander (i01000 only) The D16L-iO LED Display Expanders provide LED annunciation for up to 16 zones. It provides two LEDs for each zone. Two D16L-iO LED display expanders can be installed in each iOl 000 panel. (3) (4) Specifications 1064 101000 Device loops 1 loop Class B or Class A (Styles 4, 6, 7) supporting up to 1 loop, expandable to 4, Class A or B (Styles 4, 6, 7), 64 device addresses (any combination of detectors and each loop supporting up to 250 device addresses (125 modules) detectors and 125 modules max.). Addresses 1 t 125 are Maximum T-taps: 63 for detectors and addresses 126 to 250 are for modules (each device can be on its own branch) Maximum T-taps/loop: 124 Notification appliance 2 Class B (Style 'fl, Class A (Style Z) optional 4 Class B (Style fl or 2 Class A (Style Z) circuits 3.75 A FWR total at 120/230 VAC 60 Hz 6.0 A FWR total at 120/230 VAC 60 Hz 3.0 A FWR total at 230 VAC 50 Hz 5.0 A FWR total at 230 VAC 50 Hz 2.5 A FWR each max. per circuit 2.5 A FWR each max. per circuit Primary power 120 VAC, 60 Hz, 1.3 A max. 120 VAC, 60 Hz, 2.0 A max. 230 VAC, 50-60 Hz, 0.62 A max. 230 VAC, 50-60 Hz, 0.97 A max. Base panel current standby 155 mA 172 mA Base panel current alarm 204 mA 267 mA Input zones 16 max. 32 max. Remote annunciator 8 drops max., RS-485 Class B, Class A is optional 8 drops max., RS-485 Class A or B Data line length: 4,000 ft. (1,219 m) Data line length: 4,000 ft. (1,219 m) Operating voltage 24 VDC panel Auxiliary power output Aux power 1: 500 mA, 24 VDC circuit Aux power 2: 500 mA, 24 VDC (1 A possible if you reduce total available NAC power by 500 mA) Output: 28.3 to 21.9 VDC, special application Note: For a list of compatible devices, see the 1064 and 101000 Series Compatibility List (P/N 3102353-EN) Loop circuit Maximum loop resistance: 66 0 Maximum loop capacitance: 0.5 pF Communication line voltage: Maximum 20.6 V peak-to-peak Operating current (fully loaded loop) Stand by: 55 mA/45 mA AJarm: 125 mN115 mA (not including two-wire smoke modules) Circuit current: 0.5 A max. Style 4, 6, and 7 wiring Max. resistance between isolators: Limited only by overall wire run lengths 64 isolators maximum per loop (total both isolator bases and modules) Batteries Type: Sealed lead acid Voltage: 24 VDC Charging current: 2.47 A max. Amp hour capacity: 26 Ah Standby operation: 24 hour or 60 hour Placement: Up to two 10 Ah batteries will fit in the i064 control panel cabinet and two 18 Ah batteries will fit in the iO1 000 control panel cabinet. If larger batteries are required, use an EDWARDS battery cabinet. SA-DACT dialer Phone line type: One or two loop-start lines on a public, switched network Phone line connector: RJ-31/38X (C31/38) Communication formats: Contact ID (SIA DC-05) Operating current Standby/Alarm: 41 mA Max.: 100 mA FCC registration number: GESAL01 BSADACT Industry Canada Registration number: 3944A-SADACT Ringer equivalence number: 0.1 B Ground fault impedance 0 to 5 kO Alarm contact Form C N.O. 24 VDC at 1 A (resistive load) Trouble contact Form C 24 VDC at 1 A (resistive load) Supervisory contact Form A N.O. 24 VDC at 1 A (resistive load) Environmental Temperature: 0 to 49°C (32 to 120°F) Relative humidity: 0 to 93% noncondensing Terminal rating All terminals rated for 12 to 18 AWG (0.75 to 2.5 mm2) Page 7 of 8 E85001-0135 - -',. Issue 1.1 E SA1E'Y 6. NCINT MANArMENT Contact us... Email: edwards.fire@fs.utc.com Web: Edwards-flre.com EDWARDS is a UTC brand. 1016 Corporate Park Drive Mebane, NC 27302 © 2016 United Technologies Corporation. All rights reserved. Ordering Information Part Description i01000 Fire Alarm Systems 1010000 Four loop system with one 250-point loop installed. ilOv, gray door. 1010000-2 Four loop system with one 250-point loop installed. 230v, gray door. l01 000G-2-PG Four loop system with one 250-point loop installed. 230v, gray door, Portuguese. I01000G-2-SP Four loop system with one 250-point loop installed. 230v, gray door, Spanish. 101 000G-CA Four loop system, one 250-point loop installed. 110v, gray door, LED strips, Canada. 01 000GD Four loop system, one 250-point loop installed. iiOv, gray door, with dialer. 010000-F Four loop system, one 250-point loop. 110v, gray door, LED strips, French Canada. 1010000-PG Four loop system with one 250-point loop installed. 110v, gray door, Portuguese. 01 000G-SP Four loop system with one 250-point loop installed. 110v, gray door, Spanish. I01000R Four loop system with one 250-point loop installed. 110v, red door. I01000R-2 Four loon system with one 250-noint loon installed. 230v. red door. I01000RD Four loop system, one 250-point loop installed. 110v, red door, with dialer. SA-TR1M2 i01 000 Flush mount trim, black. 1064G One loop system with one 64-point loop installed. liOv, gray door. 10640-2 One loop system with one 64-point loop installed. 230v, gray door. 1064G-2-PG One loop system with one 64-point loop installed. 230v, gray door, Portuguese. 1064G-2-SP One loop system with one 64-point loop installed. 230v, gray door, Spanish. 1064GD One loop system, one 64-point loop installed. ilOv, gray door, with dialer. 10640L One loop system, one 64-point loop installed. ii 0v, gray door, English Canada. 1064GL-F One loop system, one 64-point loop installed. 110v, gray door, French Canada. 1064G-PG One boo system with one 64-ooint loon installed. liDv. orav door. Portuauese lO64R One loop system with one 64-point 1000 installed. 110v. red door. - with one 1064RD One loop system, one 64-point loop installed. liOv. red door, with dialer. iu-tjw txpansion mooure, one ou-aevice loop. iO-SDC2 Expansion module, two 250-device loops, 500 devices total. For 101000 only. RZI1 6-2 Remote Zone Interface Module. 16 Class B IDCs, 2 Class B Output. Includes bracket. SA-DACT Dual Line Dialer/Modem, supports Contact ID, mounts in cabinet on base plate. SA-232 RS-232 Serial Port for connection to printers & computers, mounts in cabinet. SA-CLA Class A adapter module. Provides Class A capacity on NACs. Mounts in cabinet on main board. 1064 systems only. D16L-iO-2 LED Annunciator module, 16 X 2-LED zones (4 programmable for sup). Mounts in cabinet to right of LCD display for zones 17-32. For 101000 only. D16L-iO-1 LED Annunciator module, 16 X 2-LED zones (4 programmable for sup). Mounts in cabinet to left of LCD display for zones 1-16. For iO1 000 only. D8RY-iO-2 Canada only: LED Annunciator module, two LEDs per zone, 16 zones (4 alarm only, 8 supervisory only, 4 alarm or supervisory). Mounts in cabinet. For iOi000 only. D8RY-iO-1 Canada only: LED Annunciator module, two LEDs per zone, 16 zones (4 alarm only, 8 supervisoryly, 4 alarm or supervisory). Mounts in cabinet. For i01 000 only. Accessories CTM City Tie Module. 2-gang. Connection to local energy fire alarm box. MFC-A Multifunction Fire Cabinet, 8° x 14" x 3.5" - red. SIGA-REL Releasing Module PT-iS System Printer BC-1 Battery Cabinet. 14.0" x 18.25° x 7.25°. Holds two 12V24A batteries. BC-1R Battery Cabinet - Red. 14.0" x 18.25" x 7.25". Holds two 12V24A batteries. BC-1 EQ Seismic hardening Kit for lO series panels. Includes battery hardening for BC-1 enclosure and components to harden panel internal components. Programminci Tools iO-CU 10 Series conliciuration and diacinostics utility. 260097 RS232 cable, 4 conductor, DB9 PC interface Page 8of8 E85001-0135 Issue 1.1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-1657:0244 Page 1 of 2 CATEGORY: 7165 - FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Single and multi-loop analog addressable fire alarm control unit. Local, local with shunt, auxiliary, remote station, central station, releasing device. Power limited, non-coded, coded, shunt, reverse polarity, DACT, manual, automatic waterfiow and sprinkler supervisory service. Models "EST" iO1000G, iO1000G-2, iO1000GD, i01000R, iO1000R-2, iO1000RD, i064G, 1064-GD, 1064-R, i064-RD, i064G-2, i064R-2; i0500G, i0500GD, i0500R, i0500RD, i0500G-2, i0500R-2. Models "Vigilant/Kidde" VSI-G, VSI-GD, VSI-R, VSI-RD, VSI-G-2, VSI-R-2; VS2-G, VS2-GD, VS2-R, VS2-RD, VS2-G-2, VS2-R-2, vs4-G, vs4-G-2, v54-GD, v54-R, vs4_r-2, vs4-RD,. Models "FireworX/Kidde" FX-64G, FX-64GD, FX-64R, FX-64RD, FX64G-2, FX-64R-2, FX-254G, FX-254G0, FX-254R, FX-254RD, FX254G-2, FX-254R-2, FX-1000, FXI000D. Models "Edwards Signaling" E-FSA64G, E-FSA64GD, E-FSA64R, E-FSA64RD, E-FSA250G, E-FSA250GD, E-FSA250R, E-FSA250RD System Components: SA-DACT; Dialer SA-CLA; Class A Adapter SA-ETH; Ethernet Adapter SA-232; RS232 Module DI6L-iO, -VS, -Fa, D8RY-i0-1, D8RY-i0-2, D8RY-VS, 16 Zone Front Panel LED XAL250, V-SLC, XALI27; SLC Loop Driver io-SDCI, V-SLC2-1, FX-SLC1 Single SLC Card, 250pt io-SDC2, V-SLC2-2, FX-SLC2 Dual SLC Card, *500pt *pll..S: System Printer *PTI..P: System Printer Parallel Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120/230 VAC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. "10-24-16 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed '\ the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-1657:0244 Page 2 of 2 MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as fire alarm control units for use with separately listed compatible initiating and indicating devices. *These control units meet the requirement of UL 864, 9th Edition Standard. *102416 dc ri This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTIL.LO, Program Coordinator Fire Engineering Division I—E9 TELG UARD TG-7FS LIE-V P/N: TG7LVFO1 CELLULAR ALARM COMMUNICATOR FOR LIE NETWORKS t COMMERCIAL FIRE PRODUCT FEATURES 1- Certified for use on Verizon's LIE network for long, sunset-free installation. 1- Meets UL 864 requirements for sole, primary or backup path communications. ½ I- Minimizes false alarms by providing dual paths for self-tests. The Telguard TG-7FS LIE-V is the ideal cellular alarm communications solution for commercial fire systems. The TG-717S LIE-V transmits alarm signals from the fire panel over the digital cellular network to the r designated monitoring station. Compliant with the 2013 Edition of NFPA 72, the IC-7FS LIE-V can serve as the sole communications path for the fire alarm system. It replaces all of the landlines currently dedicated to the master control unit. On average, cellular monitoring costs the end user significantly less than a dedicated landline. For each landline replaced with a TG-7FS LTE-V, the monthly communications bill decreases. By being able to signal failures to the central station within sixty minutes of an outage. the TG-7FS LIE-V can be installed as the sole path for commercial fire installations. For existing installations, all andlines can be swapped for a single TG-7FS LIE-V because of the new sixty minute supervision mode. The TG-7FS LIE-V can also be installed as a backup path and upgraded to sole path at a later date. 1 1 Telguard Cellular Service __71 Advanced Reliability 1 7 5 TeIguard Portal- Telguard makes adopting cellular easy with a secure Internet portal. The straightforward web interface allows security dealers and central stations to quickly and efficiently access lelguard based services 24/7 This advanced tool has multi-level user authorization and provides total account management of UL Listed lelguard cellular alarm communicators. Telguard Cellular Service provides Verizon LIE network coverage for all lelguard units. Telguard's Communication Center is UL compliant and provides seamless connectivity between the alarm panel, the lelguard family of products and the central station. lelguard Technical Support provides a single point of contact for both cellular service and Ielguard product questions. Features the ability to utilize multiple cellular technologies to increase availability and reduce false alarms. Automatic self-tests with central station notification ensure the cellular system is operating. Available relay output for tripping the alarm control panel when a trouble condition occurs. 5° CELLULAR ALARM COM M U N ICATOR FOR LIE NETWORKS TG-7FS LTE-V TE LG UARD Telguard technology allows full data reporting for unlimited point-to-point signal details and maximum transmitting power for superior in-building penetration. Telguard products are easy to install, economical, and UL Listed. Accessories ACD 12, ACD 35, ACD 50, ACD 100: 12/35/50/100 feet of low loss, high performance cable. HGDL-0: High gain directional antenna. EXDL-0: External antenna, UL Listings Commercial Fire 864 • control units & accessories for fire alarm systems Commercial Burglary 365 Police Station connected burglar alarm LiflitS and 5 stems 1610 Central station burglar alarm units, Line security sorvcies Residential 985 Household lire warning systems 1023 Household burglar alarm systems iS. -' ir-si, rju"r,i ,i,,,iri, I 'n" U' ,ti,.iH ,iii,i ni I iaui'i .1-li ,',,',,'., h'P' iii -ir.i' ..IiI SECURITY SIGNALING SECURITY /\ sic verin ASSOCIATION NFPA NETWORK --4j , LISTED ____. INTERNATIONAL CERTIFIED I -- — -.. --.. __.fl Power Transmit Power: 200mW in all bands. Power Consumption: 60mA (Standby) 250mA (Transmission). Transformer: 12VAC, 800mA UL listed plug-in. Radio Transceiver LTE Bands: 4 & 13. Antenna: 9" dipole with 2dBi gain 12 ft of cable and universal mounting bracket. FCC part 15, 27 and 68 compliant. --- I Physical Details TG-7FS LTE-V: 7.5" H a 11.5" W x 3.5" D. Shipping Weight: 81bs. Operating Environment: 0°C to +50°C; up to 95% humidity (non-condensing). I Standard Features Full data reporting. Automatic self-test (60 mm. & daily). Power supply with battery harness. Locking, red metal enclosure. Two programmable supervisory trip outputs. Supports virtually all alarm formats (Contact ID, 51A2, and others) using dial capture for universal panel compatibility. Telephone line monitor built-in, with Standard Line Security. lelguarcl. a Division of Telular Corporation 3225 Cumberlancl Blvd SE Suite 300 • Atlanta, GA 30339 USA 800-229-2326, Option 5 www.TeIgLjarcl.com Copyright 2017 Telular corporation • All Rights Reserved CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM - LISTING SERVICE LISTING No. 7300-1402:0109 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: TELULAR CORP.3225 Cumberland Blvd, Suite 300, Atlanta, GA 30339 Contact: Raj Kosaraju (678) 264-2012 Fax (678) 264-2062 Email: rkosaraju@telular.com DESIGN: Models TG7LAA02, *TG7LA00I *TG7Ifi,A01 TG7LA002, *TG7LAF0I TG7LAF02, and TGKITLA2 digital cellular radio alarm transmission system for fire/burglar alarm system control units. Models TG7LAA02 and TG7LA002 are household application. Model *TG7LAF0I TG7LAF02, and TGKITLA2 are for commercial application. Refer to listee's printed data sheet for additional detailed product description and operational considerations INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as digital cellular radio alarm transmission devices to provide a standalone transmission path (cellular) for a listed compatible fire and burglar alarm control unit. It may also provide a backup communication path when used in conjunction with a DACT. This product is to be connected to a listed control panel in accordance with the installation instructions provided by the manufacturer. NOTE: Burglary and other non-fire functions were not examined. * Revised 10-03-2017 dcc " This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct Mv operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division T TM /Life Safety & Communications R-Series Remote Annunciators RLCD, RLCD-C, RLED, RLED-C, RLED24, GCI Annunciation r FbW FONM r1 I® *T ' Overview Edwards R-Series Annunciators are high-performance remote annunciators that provide status indication and common controls for compatible fire alarm control panels, including i0-Series small analog fire alarm systems. This family of annunciators offers LCD or LED annunciation. Models are available with and without com- mon controls. There are three R-Series annunciator models, plus an LED-based expander. Up to two expanders can be connected to any annun- ciator. The expander includes 24 pairs of LEDs that extend the capabilities of any of the annunciators. All annunciator models include status LEDs and an internal buzzer. Two models have an LCD text display, and one has 16 pairs of LEDs for zone annunciation. LCD models feature a large back-lit, four by twenty character per line, super-twist liquid crystal display. R-Series annunciators and expanders are mounted on a standard 4-inch square electrical box, using the included mounting ring. They can also be surface mounted in locking steel enclosures. Three different enclosures are available. A keyswitch and graphic annunciator interface is available for R-Series annunciator applications. The keyswitch enables or dis- ables common controls. The graphic annunicator interface cards supports 32 LEDs and 16 switches on the graphic panel display. Features LCD models feature large 4 x 20 character backlit LCD display LED models provide 16 pairs of LEDs for zone annunciation Available expander extends capability with 24 pairs of LEDs Up to two expanders may be wired to each annunciator Status LEDs and internal buzzer standard on all models Common controls available for LED and LCD display models Available keyswitch for disabling common controls Standard 4-inch square electrical box mounting Class B or Class A R5485 wiring standard One-, two-, and three-position enclosures available Graphic Annunciator interface, includes common control, indi- cators and 32 LEDS No programing required, set the address and unit recieves all information from panel Page 1 of 4 -A l l, 85005-0128 Q t Issue 2 GROUND Expander I Annundator I flrat Expander IN OtT V(-) V(-) Remote Keyswitch Annunciator LSRA-RK KEYSWITCH(-)O ØTB1.1 KEYSWITCH (+)Ø Keyswitch Specifications Maximum 5 Vdc voltage Maximum 200 mA current Mounting 2-1/2 in (64 mm) deep 1-gang box Termination Screw terminals Maximum 12AWG wire size (2.5 mm sq) Contact Normally open configuration 85005-0128 r.(' to cc j ,: C Application R-Series annunciators communicate with the FACP on the RS-485 data riser. This can be configured for Class A or Class B commu- nication. Annunciators do not provide ground fault isolation. These annunciators are stand-alone units that can be powered by the FACP or by an approved power supply. :!I:H Annunciator Wiring Annunciator, Class A I FACP I AnnuncIator I RS-485 I CHI (*) IN I CHI I CHI - II CH1 (+)OUT I CH2* 0- CH2 - I I CH2 I-) IN LISTED 24 VDC CH2 (a) OUT SUPPLY CH2 (-) OUT 24VDC* 24V (*) IN 24VDC- 24V (-) IN 24V(*)OUT GROUND a—.— ____________ I lJl I-. RICO-C RLED.0 Jii 1!1 RLCD Features by model RLCD RLCD-C RLED24 FILED-C RLED24 Reset AcktSilence / / .1 - Fire Alarm I Supervisory I Ground Fault / Trouble Controls Enabled AcktSilence Reset / / - Signal Silence Drill Lamp Test / / I - LCD Display I / - - Zone Active LEDs - - 16*24 " Zone Trouble LEDs - - 16 24 a zones 13-16 may be selected as Supervisory on 1064 zones 13-16 and 29-32 maybe selected as Supervisory on 10500 Graphic Annunicator Interface The GCI Graphic Annunciator Driver is an interface card that connects the fire alarm control panel to the display panel of an LED-based graphic annunciator. The annunciator card supports 32 LEDs and 16 switches on the graphic panel display. It includes status LEDs and an internal buzzer. The graphic interface is supplied with snap track mounting. It is attached to a plastic mounting rail that requires two EIA panels. The annunciator communicates with the FACP on the RS-485 data riser. This can be configured for Class A or Class B commu- nication. The annunciator does not provide ground fault isolation. It is a stand-alone unit that can be powered by the FACP or by an approved power supply. Graphic Annunciator Interface Specifications Alarm current 146 mA at 24 Vdc (with 36 LEDs ON) Standby current 36 mA at 24 Vdc (with no LEDs ON) Maximum current 10 mA per LED Page 2 of 4 o o 0 S ON SHOMS A- Annunciator, Class B FACP RS-485 CHI ' 0 CHI - LISTED 24 VDC SUPPLY 24VDC+ 0 24V0C- Second Expander IN OUT - .0V(-) V(-(O .ØV(*) V(a)Ø FØ 1-OE EØ DO CO es SO OA AØ AnnuncIator CHI (a) IN CHI (-) IN CHI (.)OUT CHI (-) OUT 0 CH2 (-) IN 0 CH2 (') OUT 0 CH2 I-) OUT .0 24V (') IN 0 24V (-) IN 924V(.tOUT Annw,datar CHI (*) IN CHI (-) IN 0 CHI (') OUT 0 CHI (-) OUT CH2 (*) IN CH2 (-I IN 0 CH2 (a) OUT 0 CH2 (-) OUT 24V (-)IN 24V IN 0 24V (a) OUT 0 24V (-) OUT GROUND AnnuncIator CHI (a) IN CHI (-) IN 0 CHI (a) OUT 0 CHI I-) OUT 0 CH2(*( IN 0 CH2 (-) IN 0 CH2 (a) OUT 0 CH2 I-) OUT 24V (a) IN 24V IN 0 24V (a) OUT 0 24V (-I OUT GROUND Annunciator Connections Annunciator Mounting DIP switch RS-485 riser ,6 - terminals Power terminals Communication 0 0 LEDs a Expander Mounting slot Remote keyswitch terminals Expander cable terminals Annunciator Mounting ANNUNCIATOR RS-485 RISER - oo 0 0 I EXPANDER CABLE 1c, NFA I ffilk 0 D 0 Expander cable terminals Expander cable terminals DIP switch settings Switch Description and values Si to S5 The annunciator network address (in binary). Network The factory setting is for address 2. address Examples: 10000 = 101000 = 2 11000 = 3 00100 = 4 S6 Network OFF = 9600 baud (factory default setting) baud rate ON = 38,400 baud S7 to S8 Not used MOUNTING RING EXPANDER ELECTRICAL BOX Annunciator Enclosures The RA Remote Annunciator Enclosures provide secure, surface mounted protection for annunciators and extenders. Each con- sists of a back plate, hinged cover, and key lock. The enclosures are 16-gauge welded steel with a white, painted finish. Each enclosure includes a security lock and two keys. The two- and three-position enclosures have wiring channels for cor- rect routing of interconnections. The enclosures attach to a standard electrical box, and provide a mounting lip that takes the place of the integral mounting ring sup- plied with the annunciators and expanders. R-ENC2 H 9.51n 1.1 I 24.1 cm II 9.8 in 'I 24.9 cm Dimensions (H x W x D) RA-ENC1 6.3 x 9.8 x 2.0 in (16.0 x 24.9 x 5.1 cm) - RA-ENC2 12.0 x 9.8 x 2.0 in (30.5 x 24.9 x 5.1 cm) RA-ENC3 17.7 x 9.8 x 2.0 in (45.0 x 24.9 x 5.1 cm) Note: Allow approximately 2 inches (50 cm) clearance on both sides of the enclosure, to permit inserting and removing the key, and opening the door through 90 degrees. 11011 R-ENc3 6.0 in 15.2 cm T-0.9 in 2.3cn , 2.01n 5.1 cm Page 3 of 4 'L.AT - '-' 85005-0128 II -- Issue 2 Specifications RLCD-C RLCD RLED-C RLED24 Operating voltage 24 VDC, continuous. Standby current 99 mA 98 mA 28 mA 6 mA Alarm current 115 mA 113 mA 62 mA 34 mA RS-485 communications Class A or Class B, 9600 baud Data wiring 18 to 14 AWG (1.0 to 2.5 sq mm) twisted pair (6 twists per foot minimum). Maximum wire run is 4,000 ft. (1,219 m) Remote key switch circuit 5 VDC at 1 mA, power-limited, unsupervised Ground fault impedance 0 Power wiring 18 to 14 AWG (1.0 to 2.5 sq. mm) Display area 4 lines of 20 characters each Dimensions (H x W x D) 5-5/8 x 8-1/2 x 1-1/2 in. (14.3 x 21.4 x 3.8 cm) Mounting North American 4-inch square electrical box or listed enclosure DWARDS A UTC Fire & Security Company Detection & alarm since 1872 U.S. T 888-378-2329 F 866-503-3996 Canada Chubb Edwards T 519 376 2430 F 519 376 7258 Southeast Asia T: +65 6391 9300 F: +65 6391 9306 India Agency Usting UL, ULC T: +91 80 4344 2000 Operating environment Temperature: 32 to 120°F (0 to 49°C) Humidity: 0 to 93% RH, F: +91 80 4344 2050 noncondensing at 90°F (32°C) Australia T+61 392391200 Ordering Information F+61 3 9239 1299 Europe Part Description T +322725 1120 Remote Annunciators F +322721 86 13 RLCD LCD text annunciator without common controls. English. HWU-K LCD text annunciator without common controls. English. Red. HWDI- LCD text annunciator without common controls. French. RLCD-C LCD text annunciator with common controls. English. RLCD-CR LCD text annunciator with common controls. English. Red. RLCD-CF LCD text annunciator with common controls. French. RLED-C 16-pair LED zone annunciator with common controls. English. RLED-CR 16-pair LED zone annunciator with common controls. English. Red. RLED-CF 16-pair LED zone annunciator with common controls. French. Remote Expanders RLED24 24-pair LED zone expander with expander cable and zone card insert. RLED24R 24-pair LED zone expander with expander cable and zone card insert. Red. Enclosures RA-ENC1 One-position enclosure for Remote Annunciator. RA-ENC2 Two-position enclosure for Remote Annunciator and one Remote Expander, including one interconnection cable. RA-ENC3 Three-position enclosure for Remote Annunciator and two Remote Expanders, including two interconnection cables. LSRA-SB Surface Mount Box - for single R Series annunciator. Graphic Annunciator Drivers GCI Graphic Annunciator Driver, provides outputs for common indicators and 32 alarm/ supv zones as well as inputs for common switches. Provided with a snap track for mounting in custom graphic enclosures. Accessories RKEY Remote key switch on plate for enabling or disabling common controls (Lock' Unlock). 27193-16 Electrical box, surface mount, white, single-gang, for RKEY. Latin America T 305 593 4301 F 305 593 4300 utcfileandsecuritycom © 2010 UTC Fire & Security. All rights reserved. Page 4 of 4 ShE L 85005-0128 C ft ', r '. - '_ 11 - Issue 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM 6- .;; LISTING SERVICE M,104~ LISTING No. 7120-1657:0254 Page 1 of I CATEGORY: 7120 -- ANNUNCIATORS LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models RLCD, E- RLCD, RLCDF, RLCD-C, E- RLCD-C, RLCD-CF "LCC' Annunciators; RLED-C, E- RLED-C, RLED-CF "LED" Annunciators; RA-ENCI, RA-ENC2, RA-ENC3 Cabinets; RLED24 Remote Expander, LED24X Remote Annunciator Expander, Rkey Remote Key Switch; GCI, *GCI.NB and GCIX *Drivers Models RLCD, RLED, RLED24 may be followed by "R" which designates the color red. * GCI-24R, GCI-24Y, GCI-24G and GCI-24RY Remote LED Display Modules; *GCI..125/12R GCl-125/12Y, GCl-125/12G, GCI-125/12B, GCI-12S/I2RY, GCI-12S/I2YY, GCI-12S/I2GY and GCl-CC Remote LED Display/Switch Modules; GCI-FP *Filler Plate Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as remote annunciators and accessories for use with separately listed compatible fire alarm control units. *Rev 06-11-14 gt si This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct eftV,G operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division - i Intelligent Initiating Devices United Technologies Intelligent Smoke Detector SIGA-PD Overview The Signature Series SIGA-PD optical smoke detector brings ad- vanced sensing technology to a practical design that increases ef- ficiency, saves installation time, cuts costs, and extends life safety and property protection capabilities. Continuous self-diagnostics ensure reliability over the long-haul, while environmental compen- sation helps reduce maintenance costs. Like all Signature Series detectors, the SIGA-PD is an intelligent device that gathers analog information from its optical sensor, converting this data into digital signals. To make an alarm decision, the detector's on-board microprocessor measures and analyzes sensor readings and compares this information to historical data. Digital filters remove signal patterns that are not typical of fires, thus virtually eliminating unwanted alarms. ~ r~o 0 [1 S853 * Standard Features Note: Some features described here may not be supported by all control systems. Check your control panel's Installation and Operation Guide for details. Next Generation Optical Smoke Sensing Technology Wide 0.53 to 3.94 %/ft. (1.7 to 12.35 %/m) smoke obscuration Uses Existing Wiring Automatic Device Mapping Up To 250 Total Signature Addresses Per Loop Two Levels of Environmental Compensation Two Levels of Dirty Detector Warning Twenty Pre-Alarm Settings Five Sensitivity Settings Non-Volatile Memory Electronic Addressing Identification of Dirty or Defective Detectors Automatic Day/Night Sensitivity Adjustment Bicolor (Green/Red) Status Led Standard, Relay, Fault Isolator, and Audible Mounting Bases Sensor Markings Provide Easy Testing Identification Page 1 of 4 O.TA SHEET E85001-0646 'l ot LO be jsj Or t.tatpoo puioo'r Issue 1 Application The SIGA-PD detects extremely small particles of combustion and triggers an alarm at the first sign of smoke. Thanks to its high- performance forward-scattering reflective response technology, the photoelectric smoke sensor responds quickly and reliably to a wide range of fire types, especially slow burning fires fuelled by combustibles typically found in modern multi-use buildings. Compatibility The SlGA-PD detector is compatible only with the Signature Loop Controller. Installation Signature Series detectors mount to North American 1-gang boxes, 3-1/2 inch or 4 inch octagon 4i) boxes, and to 4 inch square elec- Selfiocking tab trical boxes 1-1/2 inches (38 mm) deep. They mount to European BESA and 1-gang boxes with 60.3 mm fixing centers. See mounting LED Indicator base installation and wiring for more information. Sensing and reporting technology The microprocessor in each detector provides additional benefits - Self-diagnostics and History Log, Automatic Device Mapping, and Fast, Stable Communication. Self-diagnostics and History Log - Each Signature Series detector constantly runs self-checks to provide important mainte- nance information. The results of the self-check are automatically updated and permanently stored in the detector's non-volatile memory Automatic Device Mapping - The loop controller learns where each device's serial number address is installed relative to other devices on the circuit. The mapping feature provides supervision of each device's installed location to prevent a detector from being reinstalled (after cleaning etc.) in a different location from where it was originally. Fast Stable Communication - On-board intelligence means less information needs to be sent between the detector and the loop controller. Other than regular supervisory polling response, the detector only needs to communicate with the loop controller when it has something new to report. Testing & Maintenance Each detector automatically identifies when it is dirty or defective and causes a "dirty detector" message. The detector's sensitiv- ity measurement can also be transmitted to the loop controller. A sensitivity report may be printed to satisfy NFPA sensitivity mea- surements, which must be conducted at the end of the first year and every two years thereafter. The user-friendly maintenance program shows the current state of each detector and other pertinent messages. Single detectors may be turned off temporarily from the control panel. Availability of maintenance features is dependent on the fire alarm system used. Accessories Detector mounting bases have wiring terminals that are acces- sible from the "room-side" after mounting the base to the electrical box. The bases mount to North American 1-gang boxes and to 31h inch or 4 inch octagon boxes, 1½ inches (38 mm) deep. They also mount to European BESA and 1-gang boxes with 60.3 mm fixing centers. The SIGA-SB4, SIGA-RB4, and SlGA-1134 mount to North American 4 inch sq. electrical boxes in addition to the above boxes. They include the SIGA-TS4 Trim Skirt, which is used to cover the "mounting ears" on the base. The SIGA-AB4G mounts to a 4 inch square box only. 6 :0V SIGA-AB4G/TiLF SIGA-SB SIGA-18 SIGA-RB SIGA-LED Audible Base Standard Base Isolator Base Relay Base Remote LED Remote LED SIGA-LED - The remote LED connects to the SIGA-SB or SIGA-SB4 Standard Base only. It features a North American size 1-gang plastic faceplate with a white finish and red alarm LED. SIGA-TS4 Trim Skirt - Supplied with 4 inch bases, it can also be ordered separately to use with the other bases to help hide surface imperfections not covered by the smaller bases. Sounder Bases - Signature Series sounder bases are designed for use where localized or group alarm signaling is required. SIGA-AB4G bases provide sounder capability to Signature Series to heat and smoke detectors. They are not intended for use with combination carbon monoxide detectors in Fire- plus-CO mode. SIGA-AB4GT bases provide sounder capability to Signature Series smoke and heat detectors, as well as carbon monox- ide detectors when used with a SIGA-TCDR Temporal Pattern Generator. SIGA-AB4G-LF bases provide 520 Hz low frequency sounder capability to Signature Series smoke and heat detec- tors, as well as carbon monoxide detectors when used with a SIGA-TCDR Temporal Pattern Generator. The SIGA-AB4G-LF is suitable for applications requiring low frequency audible tones. Page 2 of 4 CA SIE1 E85001-0646 b u 0 tip n. JL_; c ur Jt?. Issue I Typical Wiring The detector mounting bases accept #18 AWG (0.75mm2), #16 Audible Sounder Bases, Fire Mode (1.0mm2), #14 AWG (1 .5mm2), and #12 AWG (2.5mm2) wire sizes. AB4GT1 AB4G, AB4G-LF sounder bases Sizes #16 AWG (1.0mm2) and #18 AWG (0.75mm2) are preferred for ease of installation. ________•\ /__ Standard Detector Base, SIGA-SB, SIGA-SB4 U Output Mode This is the basic mounting base Jumper SIGA-AB4G-LF: cuts Default = Fire Volume Setting cut/remove Jumper for for EDWARDS Signature Series tonce Default = High Fire plus co ire detectors. The SlGA-LED Re- exceed cut/remove jumper for SIGA-AB4G: mote LED is supported by this ma iowdB Tons Setting Base. DATA- DAIS. DATA. Default = Temporal Term Description Jpe am. nix- our a recur cut/remove jumper for 1NotUsed 2 DATA iN/OUT(i-) L I- ISIGA-AB4GT: Steady DATAIN(-) 4 NotUsed Not Used Remote LED DATA ATA mt 5 Remote LED ______ I 6 Not Used I 7 DATA OUT (-) DATA IN 1+1 DATA OUT 1+1 From Signature Controller To Next Device 24 Vdc In ___ From power supply -, - 24 Vdc out or Previous Device or previous base + - + To next base or EOL relay Isolator Detector Base, SIGA-IB, SIGA-IB4 - Data out Detain -) to next Signature device From Signature Controller _______________ or previous device • + This base includes a built-in line fault isolator for use on Class A circuits. A detector must be installed for it to operate. The isolator base does not support the SIGA-LED Remote LED. Warnings & Cautions This detector does not operate without electrical power. As - a short on the line causes all fires frequently cause power interruption, discuss further lators to open within 23 mse safeguards with the local fire protection specialist. The isolator operates as followA - at 10 msec intervals, • beginning on one side of This detector does not sense fires in areas where smoke the Class A our cannot reach the detector. Smoke from fires in walls, roofs, circuit nearest the loop or on the opposite side of closed doors may not reach the controller, the isolators detector. close to provide the DATA IN DATA OUT (+) next isolator down the From Signature Controller To Next Device or Previous Device Photoelectric detectors have a wide range of fire-sensing line with power I Term DescriptIon I capabilities and are best suited for detecting slow, smolder- Ii Not Used - when the isolator next 2 DATA IN/OUT (+) ing fires. to the short closes, it reopens within 10 3 DATA IN (-) 4 Not Used I In Canada, install according to CAN/ULC-5524 Standard for msec. 5 Not Used I 6 DATA OuT(-) the Installation of Fire Alarm Systems, CSA C22.1 Canadian The process repeats beginning on the 7 Not Used Electrical Code, and the local authority having jurisdiction. other side of the loop controller. Relay Detector Base, SIGA-RB, SIGA-RB4 This base includes a relay. Nor- mally Open or Normally Closed operation is selected during in- stallation. The dry contact is rated for amp (pilot duty) @30 Vdc. The relay's position is supervised to avoid accidentally jarring it out of position. The SIGA-RB can be DATAlNct operated as a control relay if pro- grammea to do so at the control —IN(.) W Ffom Controller To Next Device panel. The relay base does not Or PiGVIOUD Device Term Description support the SIGA-LED Remote 1 Normally Open I LED. CONTACT RATING I I 2 DATAIN/OLiT(+) I 1.0 Amp @30 VDC I I 3 Common I Plot Duty) J 4 5 6 7 DATA IN (-) I Not Used I Normally-Closed I DATAOlJri - ) I Page 3014 - DATA Si E E T E85001-0646 01 to DIE 0 I..' t.. .i ci.. Issue I DWARDS '. SAFF Nr : i Contact us... Email: edwards.flra@fs.utc.com Web: Edwards-fire.com Dimensions I— - - crL.:._INI. sJiUr11, EDWARDS is a UTC brand. 1016 Corporate Park Drive Mebane, NC 27302 @2016 United Technologies Corporation. All rights reserved. Specifications 15.20 to 19.95 Normal operating current 32 pA Alarm current 32 pA Smoke Sensitivity Range UL/ULC: 0.53 to 3.94 %/ft. (1.7 to 12.35 %/m) obscuration Vibration level 10 to 35 Hz, with an amplitude of 0.01 in. Air velocity 0 to 4,000 ft./min (0 to 20 m/s) Wall mounting 12 in. (305 mm) max. from ceiling Compatible bases See Ordering Information Compatible detector testers Testifire 1000, Testifire 2000 Operating environment 32 to 120°F (0 to 49°C), 0 to 93% RH, noncondensing Construction High Impact Engineering Polymer, White Storaae temoerature -4 to 140°F (-20 to 60°C) Ordering Information Catalog Description Ship Wt. Number lbs (kg) SIGA-PD Intelligent Optical Smoke Detector 0.4 (0.16) Accessories SIGA-SB Detector Mounting Base - Standard SIGA-SB4 4-inch Detector Mounting Base c/w Trim Skirt SIGA-1121 SIGA-1134 SIGA-LED Detector Mounting Base wlRelay 4-inch Detector Mounting Base w/Relay, c/w Trim Skirt Detector Mounting Base w/Fault Isolator 4-inch Detector Mounting Base wl Fault Isolator, c/w Trim Skirt Remote AJarm LED (not for EN54 applications) 0.2 (.09) Page 4 of 4 SlGA-AB4G Audible (Sounder) Base for Fire Detectors 0.3 (0.15) SIGA-AB4G-LF Low Frequency Audible (Sounder) Base for CO and Fire Detectors 0.3 (0.15) SlGA-AB4GT Audible (Sounder) Base for CO and Fire Detectors 0.3(0.15) SlGA-TS4 Trim Skirt (supplied with 4-inch bases) 0.1 (0.04) SIGA-TS Trim Skirt - (optional for non 4-inch bases) 0.1 (0.04) SIGA-DMP Detector Mounting Plate 3.0 (1.4) SIGA-RTA Detector Removal Tool SIGA-VA Detector Cleaning Tool JATA SH'E85OO1O646 .1 o Issue 1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-1657:0331 Page 1 of 2 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, lnc.8985 Town Center Parkway, Bradenton, 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models SIGA-PD, *SIGI..PD *KI..PD and *KIR PD Analog addressable photoelectric smoke detectors.*Model SIGI-PD is similar to Model SIGA-PD except for isolation circuitry. *Model KI-PD is identical to Model SIGA-PD except for trade name. *Model KIR-PD is similar to Model SIGA-PD except for control panel compatibility. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 15.2-19.95Vdc INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72 and applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. *Models SIGA-PD and SIGI-PD are under the Edwards brand. *Models KI-PD and KIR-PD are under the Kidde brand. APPROVAL: Listed as analog addressable photoelectric smoke detectors. *Model Kl-PD is for use with listee's Models VSI, VS2 and VS4 (CSFM No. 7165-1657:0244); VM-1 (CSFM No. 7165-1657:0309) fire alarm control units. *Models SIGA-PD and SIGI-PD are for use with listee's Models EST3 (CSFM No. 7165-1657:0186); i064, i0500 and i01000 (CSFM No. 7165-1657:0244); EST3X (CSFM No. 7165-1657:0306) fire alarm control units. *Model KIR-PD is for use with listee's Models FX-64, FX-254 and FX-1000 (CSFM No. 7165-1657:0244) fire alarm control units. *Model SlGA-PD is for use with listee's bases: Models SIGA-SB, -SB4, -RB, -RB4, -IB, -I134 (CSFM No. 7300-1657:0120); SIGA-AB4G (CSFM No. 7300-1657:0222); SIGA-AB4GT (CSFM No. 7300-1657:0307) and SIGA-AB4G-LF (CSFM No. 7300-1657:0322). *Model SIGI-PD is for use with listee's bases; Models SIGI-AB4G (CSFM No. 7300-1657:0222); SIGI-AB4GT (CSFM No. 7300-1657:0307) and SIGI-AB4G-LF (CSFM No. *Rev 02-15-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7272-1657:0331 Page 2 of 2 7300-1657:0322). *Models Kl-PD and KIR-PD are for use with listee's bases; Models Kl-ABST (CSFM No. 7300-1657:0222), Kl-ABDT (CSFM No. 7300-1657:0307) and Kl-ABLT (CSFM No. 7300-1657:0322). Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires, which smolder for hours before bursting into flames. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires, which consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. *Rev 02-15-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM mliqv~ LISTING SERVICE LISTING No. 7300-1657:0120 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, lnc.8985 Town Center Parkway, Bradenton, 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Detector Bases. Base models are as follow: Models 5963B, 5964 B/BR, 624113-002, 6249B-001, 6251, 625113-00IA, -001, -002, -003, -004, 6251 B-100, -200, -R 100, -R200 and 6251-2 Models 6251 B-aOl, -002, -003 and -004 are suitable for releasing device service. Models P-847674-0022, -0024, -0042, -0043, -0044, -0045, -0046, -0047. Models SIGA-113, -1134, -RB, -RB4, -SB, -SB4 and -AB4. *Models KI-IB, -184, -RB, -RB4, -SB and -SB4. The -RB series are suitable for releasing device service. *Model SIGI-SB and SlGl-SB4. Model AB4G-SB surface mount back box for use with listee's SIGA series sounder bases. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. *KI are under the Kidde Brand. SIGA* and SlGI* are under the Edwards Brand APPROVAL: Listed as mounting bases for use with separately listed compatible detectors and fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7300-1591:120 and 7300-1388:170 *Rev 05-03-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct 01 V operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Intelligent Initiating ES T TM /LIfe Safety & Communications Manual Pull Stations SIGA-270, SIGA-270P, SIGA-278 Overview The SIGA-270 and SIGA-278 series Manual Pull Stations are part of EST's Signature Series system. The SlGA-270 Fire Alarm Manual Pull Stations feature our very familiar teardrop shape. They are made from die-cast zinc and finished with red epoxy powder- coat paint complemented by aluminum colored stripes and mark- ings. With positive pull-lever operation, one pull on the station handle breaks the glass rod and turns in a positive alarm, ensuring protection plus fool-proof operation. Presignal models (SlGA-270P) are equipped with a general alarm (GA) keyswitch for applications where two stage operation is required. The up-front highly visible glass rod discourages tampering, but is not required for proper operation. EST's double action single stage SIGA-278 station is a contempo- rary style manual station made from durable red colored lexan. To initiate an alarm, first lift the upper door marked 'LIFT THEN PULL HANDLE", then pull the alarm handle. Standard Features Note: Some features described here may not be supported by all control sys- tems. Check your control panel's Installation and Operation Guide for details. Traditional familiar appearance SlGA-270 models feature our familiar teardrop design with simple positive pull action and sturdy die-cast metal body. One stage (GA), two stage (pre-signal), and double action models SlGA-270 models are available for one or two stage alarm systems. The single stage double action SlGA-278 features a rugged Lexan housing with keyed reset mechanism. Break glass operation An up-front visible glass rod on the SlGA-270 discourages tampering. Intelligent device with integral microprocessor All decisions are made at the station allowing lower com- munication speed while substantially improving control panel response time. Less sensitive to line noise and loop wiring properties; twisted or shielded wire is not required. ADA Compliant Meets ADA requirements for manual pull stations. Electronic Addressing with Non-volatile memory Permanently stores programmable address, serial number, type of device, and job number. Automatically updates historic information including hours of operation, last maintenance date, number of alarms and troubles, and time and date of last alarm. Automatic device mapping Each station transmits wiring information to the loop control- ler regarding its location with respect to other devices on the circuit. Stand-alone operation The station inputs an alarm even if the loop controller's polling interrogation stops. Diagnostic LEDs Status LEDs; flashing GREEN shows normal polling; flashing RED shows alarm state. Designed for high ambient temperature operation Install in ambient temperatures up to 120 OF (49 00). Page 1 of 4 85001-0279 '- Issue Application The operating characteristics of the fire alarm stations are deter- mined by their sub-type code or "Personality Code". NORMALLY- OPEN ALARM - LATCHING (Pesonality Code 1) is assigned by the factory; no user configuration is required. The device is configured for Class B IDC operation. An ALARM signal is sent to the loop controller when the station's pull lever is operated. The alarm con- dition is latched at the station. Compatibility Signature Series manual stations are compatible only with EST's Signature Loop Controller. Warnings & Cautions This device will not operate without electrical power. As fires fre- quently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. Typical Wiring The fire alarm station's terminal block accepts #18 AWG (0.75mm2) to #12 AWG (2.5mm2) wire sizes. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Wiring Notes Refer to Signature Loop Controller manual for maximum wire distance. 2. All wiring is power limited and supervised. REAR VIEW of 278 Red LED Green LED (Aicim/AcRee) (Normal) Testing & Maintenance To test (or reset) the station simply open the station and operate the exposed switch. The SIGA-270 series are opened with a tool; the SIGA-278 requires the key which is supplied with that station. f DATA IN(+)> 1 DAIAINC-) > From Signature Controller or Previous Device DATA 0111(v) DATA OUT C-) To Next Device The station's automatic self-diagnosis identifies when it is defec- tive and causes a trouble message. The user-friendly maintenance program shows the current state of each Signature series device and other pertinent messages. Single devices may be deactivated temporarily, from the control panel. Availability of maintenance features is dependent on the fire alarm system used. Scheduled maintenance (Regular or Selected) for proper system operation should be planned to meet the requirements of the Authority Having Jurisdiction (AHJ). Refer to current NFPA 72 and ULC CAN/ULC 536 standards. Figure 4. Single Stage Systems REAR VIEW Of 270P, 270P8 EM CM C3 El 0 1B2 Red M LED _____ Green LED (AlarmIActt4e) -(NormaD 781 DW 0 Co C2 C:I I DATA IN )- E.DATAOUT(+) i. DATA IN(-) 9 . DATA OUT C-) J From 5jre Controller To Neat Device orPreviow Device Figure 5. Two Stage Systems Page 2 of 4 S•' 85001-0279 b. • _!.,, r Issue 8 Compatible Electrical Box Back Plate Toggle Swthh OPEN /-\ Compatible Electrical Box C RE Installation Single-stage Signature Series fire alarm manual pull stations mount to North American 21/2 inch (64 mm) deep 1-gang boxes. Two stage presignal (270P) models require 1½ inch (38 mm) deep 4-inch square boxes with i-gang, ½-inch raised covers. Openings must be angular. Rounded openings are not acceptable. Recommended box: Steel City Model 52-C-1 3; in Canada, use Iberville Model Cl- 52-0-49-1/2. All models include terminals are suited for #12 to #18 AWG (2.5 mm2 to 0.75 mm2) wire size. Edwards recommends that these fire alarm stations be installed according to latest recognized edition of national and local fire alarm codes. Electronic Addressing: The loop controller electronically addresses each manual station, saving valuable time during system com- missioning. Setting complicated switches or dials is not required. Each station has its own unique serial number stored in its on-board memory. The loop controller identifies each device on the loop and assigns a "soft" address to each serial number. If desired, the stations can be addressed using the SIGA-PRO Signature Program/Service Tool. Figure 1. SIGA-278 installation Figure 2. SIGA-270, SlGC-270F, SlGC-270B installation Cover Release Figure 3. SlGA-270P, SIGC-270PB installation Page 3of4 K i 1 85001-0279 - V 0 €" Issue 8 Specifications SIGA-270, SlGC- SIGA-270P, Catalog Number 270F, SIGC-270B SIGC-270PB SlGA-278 Description Single Action Single Action -Two Double Action - One Stage Stage (Presignal) - One Stage Addressing Uses 1 Module Uses 2 Module Uses 1 Module Requirements Address Addresses Address Operating Current Standby = 250pA Standby = 396pA Standby = 2501JA Activated = 400pA Activated = 68OpA Activated = 400pA Construction & Finish Diecast Zinc - Red Epoxy Lexan - Red with with aluminum markings white markings Type Code Factory Set Operating Voltage 15.2 to 19.95 Vdc (19 Vdc nominal) Storage and Operating Operating Temperature: 32°F to 120°F (0°C to 49°C) Environment St orage Temperature: -4°F to 140°F (-20°C to 60°C) Humidity: 0 to 93% RI-I On-board Green LED - Flashes when polled LED Operation On-board Red LED - Flashes w hen in alarm Both LEDs - Glow steady when in alarm (stand-alone) Compatibility Use With: Signature Loop Controller Agency Listings UL, ULC (note 1), MEA, CSFM Note: SIGC-270F SIGC-270B and SIGC-270PB are ULC listed only. Suffix "F" indicates French markings. Suffix "B" indicates English/French biling ual markings. Ordering Information Ship Catalog Wt. lbs Number Descriotion SlGA-270 One Stage Fire Alarm Station, English Markings - ULJULC Listed - SIGC-270F One Stage Are Alarm Station, French Markings - ULC Listed SIGC-270B One Stage Fire Alarm Station, French/English Markings - ULC Listed SIGA-270P Two Stage (Presignal) Fire Alarm Station, English Markings - UL/ULC Listed 1 (0.5) SIGC- Two Stage (Presignal) Fire Alarm Station, French/English Markings 270PB - ULC Listed SlGA278 Double Action (One Stage) Fire Alarm Station, English Markings - UL/ULC Listed . DWARDS A IJTC Fire 6 Securfty Company Detection & alarm since 1872 U.S. T 888-378-2329 F 866-503-3996 Canada Chubb Edwards T 519 376 2430 F 519 376 7258 Southeast Asia T: +65 6391 9300 F: +65 6391 9306 India T: +9180 4344 2000 F: +9180 4344 2050 Australia T+61 3 9239 1200 F+61 392391299 Europe T+32272511 20 F+322721 8613 Latin America T 305 593 4301 F 305 593 4300 utCfireandsecurity.com © 2010 UTC Fire & Security. All rights reserved. Accessories 32997 GA Key w/Tag - for pre-signal station (CANADA ONLY) 276-K2 GA Key - for pre-signal station (USA ONLY) 276-Ki Station Reset Key, Supplied with all Key Reset Stations -0.1 05 27165 12 Glass Rods - for SIGA-270 series (CANADA ONLY) 270-GLR 20 Glass Rods - for SIGA-270 series (USA ONLY) 276-GLR 20 Glass Rods - for SlGA-278 series 276B-RSB Surface Mount Box, Red - for SIGA pull stations 1 (0.6) Page 4of4 E f 85001-0279 - ' Issue 8 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL m FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-1657:0129 Page 1 of I CATEGORY: 7150 -- FIRE ALARM PULL BOXES LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, lnc.8985 Town Center Parkway, Bradenton, 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models SIGA-270, SIGA-270P, and SIGA-278 noncoded, intelligent manual pull stations*. Unit consists of a listed pull station and a remote transponder. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as manual pull stations for use with separately listed compatible fire alarm control units. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition with California amendments. NOTE: Formerly 7150-1591:129 and 7150-1388:194 7-29-10 ma This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed f\ the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division jEG TT M Intelligent Initiating We Safely & Communications Intelligent Duct Smoke Detector Housing SIGA-DH Overview The SIGA-DH Duct Smoke Detector Housing is specially engi- neered to exploit all the capabilities of Signature Series intelligent photoelectric and multisensor smoke detectors. Edwards Signa- ture Series detectors gather analog information from each of their one or more sensing elements and converts it into digital signals. The detector's onboard microprocessor measures and analyzes these signals. It compares them to historical readings, time pat- terns and known characteristics to make an alarm decision. Digital filters and complex Algorithms are applied for optimum detector accuracy. Unwanted alarms are virtually eliminated. Each duct housing is packaged with detailed installation instruc- tions, gaskets and a self-adhesive drilling template for locating and mounting the detector. The large access door is completely re- movable to allow fast detector installation and field wiring connec- tions. The 16 gauge steel housing is finished in red baked enamel for easy identification. Five one-gang knockouts on the housing provide a convenient location for mounting intelligent Signature Series modules. The SIGA-DH Duct Housing comes with a 6 inch (150 mm) exhaust tube. Air sampling tubes are available in lengths from 8 inches (200 mm) to 10 feet (3048 mm) and must be ordered sepa- rately. Compatible smoke detectors, mounting bases, and acces- sories are listed in the Ordering Information. Refer to individual device catalog literature pages for more detail. Standard Features Suitable for high air velocity duct applications Up to 4000 ft/mm. (20.3 m/sec.) with Photoelectric Detector. Standard Signature Series detectors Designed for use with standard 4D, 3D, and Photoelectric Signature Series smoke detectors. Does not require "special" duct smoke heads. Standard, relay, or isolator detector base Detector plugs-in to base then easily installs into housing. Install inducts up to lOft. (3.05 m) wide Remote LED and test station accessories Designed and manufactured to ISO 9001 standards Typical Wiring The detector mounting bases and test station will accept #18 AWG (0.75mm2), #16(1.0mm2), #14 AWG (1.50mm2) and #12 AWG (2.5 mmg wire sizes. Note: #14 AWG (1.5 mm2) is not recommended due to difficulty of installation. See Loop Control- ler and Detector catalog sheets for detailed wiring requirement specifications. Page 1 of 4 I~A T,a -'EE 85001-0325 1. Issue 4 Application The SIGA-DH Duct Smoke Detector Housing requires a clear, flat, accessible area on the duct of at least 7-3/8 inches (188mm) W x 7 inches (175mm) H. The duct housing must be installed on ducts at least 8 inches (200mm) wide. To avoid the effects of stratifica- tion, install the detector housing a minimum of six duct widths beyond any bends in the duct. Duct detectors are usually installed on the supply duct after the air filters; or in the return air stream prior to being diluted by outside air. Sample tube length must span the entire width of the air duct and the tube can be easily cut to any length. Inlet tubes longer than 3 ft.(900mm) must be supported at both ends. Bend or other obstruction Duct - width 6 Duct widths Duct detector (minimum) location Duct detectors continually sample air flow in a HVAC duct and initiate an alarm condition whenever smoke is detected. An alarm is activated when the quantity (percent obscuration) of combustion products in that air sample exceeds the detector's sensitivity setting. Air velocity in the duct maintains the air flow that enters the detec- tor housing through perforations in the air sampling inlet tube and discharges through the outlet exhaust tube. The detector housing must be installed with its INLET air sampling tube upstream of the EXHAUST tube. Before installing the duct detector housing, test the duct air velocity to verify it is within the limits of the Signature smoke detector that is being installed. Also verify that duct air rela- tive humidity is within 0% and 93%. WARNING: Duct detectors have specific limitations. Duct detec- tors ARE NOT a substitute for an open area smoke detector. Duct detectors ARE NOT a substitute for early warning detection. Duct detectors ARE NOT a replacement for a building's regular fire detection system. Smoke detectors ARE NOT designed to detect toxic gases which can build up to hazardous levels in some fires. These devices WILL NOT operate without electrical power. As fires frequently cause power interruptions, Edwards suggests you discuss further safeguards with your local fire protection specialist. Installation and Mounting Edwards recommends duct detectors always be installed in ac- cordance with the latest recognized editions of local and national fire alarm codes. Typical Wiring Accessories Duct Detector Air Sampling Tubes One air sampling inlet tube must be ordered for each duct smoke detector housing. Refer to Ordering Information for available lengths. Detector Mounting Bases One detector mounting base must be ordered for each duct smoke housing. Removing a detector from its base (except isola- tor base) does not affect other devices operating on the same data loop. Available bases are: Standard Base SIGA-SB - This is the basic mounting base. The SIGA-LED Remote LED IA- supported by the Standard Base. Relay Base SIGA-RB - This base includes a relay. Normally open or closed operation is selected during installation. The dry contact is rated for 1 amp © 30 Vdc (pilot duty). The relay's position is supervised to avoid accidentally jarring it out of position. The SIGA-RB can be operated as a control relay if pro- grammed to do so at the control panel (EST3 V. 2 only). The Relay Base does not support the SIGA-LED Remote LED. Relay bases are not affected or activated by the SIGA-DTS Duct Test Station. Isolator Base SIGA-19 - This base includes a built-in line fault isolator. A detector must be installed for it to operate. The integral isolator relay is controlled by the detector or the loop controller. A maximum of 96 isolator bases can be installed on one loop. The Isolator Base does not support the SIGA-LED Remote LED. Alarm LED Indicator The SIGA-LED Alarm Indicator is suitable for use with the SIGA-SB detector base only. A maximum of one can be operated for each detector. It features a red LED on a one-gang plastic plate and can be installed remote or directly on the SIGA-DH Duct Housing. Duct Test Station The SIGA-DTS Duct Test Station uses a key switch along with an integral intelligent input module mounted on a two-gang plastic plate. It is supplied with two keys and features a red alarm LED. When the key is turned to the "TEST" position, the LED lights and the integral module remotely inputs a duct detector test alarm. The actions and sequences programmed at the control panel to activate dampers and other smoke control measures, are easily tested. Detector relay bases are not affected or activated. Resetting the control panel clears the test and returns the system to normal. The key cannot be removed when in the "TEST" position. The Duct Test Station mounts to standard 2-inch deep North American two-gang and 4-inch square electric boxes and Euro- pean 100 mm square boxes. Air Velocity Test Kit The 6263-SG Air Velocity Test Kit is specially designed to interface to the SIGA-DH Duct Housing. It is used to test or confirm the air velocity in HVAC ducts where the duct housing is installed. The detector mounting bases and test station will accept #18 AWG (0.75mm2), #16(1.0mm2), #14 AWG (1.50mm2) and #12 AWG (2.5 mm2) wire sizes. Note: #14 AWG (1.5 mm2) is not recommended due to difficulty of installation. See Loop Control- ler and Detector catalog sheets for detailed wiring requirement specifications. Page 20f4 -I s r 85001-0325 '.1, T. - Issue Specifications Compatible Smoke Detectors SIGA-PS SIGA-PHS SIGA-IPHS Ionization Photoelectric Photoelectric - Unipolar Photoelectric Smoke Sensing Element(s) - LightScattering Principle - Light Scattering Principle Heat - - Light Scattering Principle Heat 135°F (57°C) Fixed Temperature - Alarms at 65° F (35° C) change in ambient temperature Air Velocity Range 300 to 4000 ft/mm. (1.5 to 20.3 m/sec) 300 to 1000 fVmin. Temperature: 32 - 120° F (0 to Operating Environment 49° C) Temperature: 32 - 100° F (0 - 38° C) Humidity: 0 to 93% RH, Humidity: 0 to 93% RH, non-condensing non-condensing Storage Environment Temperature: -4 to 140° F (-20 to 60°C); Humidity: 0 to 93% RH, non-condensing ULI/ULC Sensitivity Range 0.67% to 3.77% obscuration/foot (305mm) obscuratiorVfoot(305mm) Dimensions 7-3/8 inches (188mm) W x 7 inches (178mm) H x 5 inches (127mm) D Material and Finish 16 Gauge Cold Rolled Steel, Red - Baked Enamel Conduit Knockouts Combination 1/2 inch & 3/4 inch Agency Approvals UL, ULC, MEA, CSFM User Selected Sensitivity Settings Least Sensitive: 3.5%; Less Sensitive: 3.0%; Normal: 2.5%; More Sensitive: 2.0%; Most Sensitive: 1.0% Pie-alarm Sensitivity 5 % increments, allowing up to 20 pre-alarm settings Electrical, Physical Characteristics Refer to individual detector catalog sheets Compatible Mounting Bases SlGA-SIB Standard Base, SIGA-RB Relay Base, SlGA-113 Isolator Base Compatible Remote LED SIGA-LED (LED flashes when in alarm) Controller Compatibility SIGNATURE Loop Controller Addressing Restrictions Uses one Input Device Address Note: The SIGA-DH Duct Housing is not weatherproof or dust tight.) SIGA-DTS Duct Test Housing Operating Current Standby = 250pA; Activated = 400pA Operating Voitage 15.2 to 19.95 Vdc (19 Vdc nominal) Replacement Key p/n - P-037449 Storage and Operating Temperature 32 to 120°F (0 to 49°C) Onboard LED Operation Red LED - flashes when in alarm or test state Mounting North American electric box: 2 inch deep 2-gang or 4 inch square; European electric box: 100 mm square Construction & Finish High Impact Engineered Plastic 2-gang front plate - White Addressing Restrictions Uses one Module Address - - Page 3 of 4 85001-0325 0 b A 1 ) Issue 4 Detection & alarm since 1872 Ordering Information Catalog Number Description Ship Wt lb. (kg) SlGA-DH Duct Detector Housing 6.5(3.0) Tubes 6261-002 24 inch (600mm) Air Sampling Inlet Tube 0.5 (0.2) 6261-003 42 inch (1060mm) Air Sampling Inlet Tube 1.6 (0.8) 6261-006 78 inch (1980mm) Air Sampling Inlet Tube 2.2 (1.0) 6261-010 120 inch (3048mm) Air Sampling Inlet Tube 4.4 (2.0) Compatible Detectors and Bases SlGA-IPHS 4D Multisensor Detector 0.5(0.23) SIGA-PHS 31) Multisensor Detector 0.5(0.23) SIGA-PS Photoelectric Detector 0.5(0.23) SlGA-SB Standard Base 0.2(0.09) SlGA-RB Relay Base 0.2 (0.09) SIGA-IB Isolator Base 0.2 (0.09 Annunciation and Testing SIGA-LED Alarm LED Indicator 0.2 (.09) SIGA-DTS Duct Test Station 0.4 (.18) I!4fl S DWARDS A trrc Fire & Security Company U.S. 1888-378-2329 F 866-503-3996 Canada Chubb Edwards 15193762430 F 519 376 7258 Southeast Asia T: +65 6391 9300 F: +65 6391 9306 India 1: +9180 4344 2000 F: +9180 4344 2050 Australia 1+61 3 9239 1200 F+61 3 9239 1299 Europe T+32272511 20 F+32272186 13 Latin America T 305 593 4301 F 305 593 4300 utcfireandsecurttycom @2010 UTC Fire & Security. All rights reserved. Page 4 of 4 85001-0325 - Issue 4 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL OU LISTING SERVICE FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM ®r LISTING No. 3240-1657:0108 Page 1 of I CATEGORY: 3240 - DUCT SMOKE DETECTOR HOUSING/BASE LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models 6260(1)-100, 6265(1)-001/-002, 2435P, 1235B, A19863, SIGA-DH, and 6260A-CU Duct Smoke Detector Units. Unit consists of a metal enclosure, relay, electrical components, a separately listed open area detector, a detector base and a sampling and exhaust tubes. Refer to listee's data sheet for additional detailed product description and operational considerations. (1): First four digits followed by an alpha suffix. RATING: 300-4000 fpm except for Model 6260B-100 is range from 400-4000 fpm. Model SIGA-DH with Model SIGA-IPHS detector head, the sensitivity must be set at Levels I through 4 for velocities over 1000 fpm. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating and UL label. APPROVAL: Listed as duct smoke detector housing units for use with separately listed compatible control units. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 3240-1591:108, 3240-1388:104, 3240-0073:141, 3242-0073:141, 3240-0073:118 and 3241-0073:118 7-29-10 ma This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any daims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Intelligent Initiating OT TU ,/Llfe Safety & Communications Intelligent Photoelectric Smoke Detector SIGA-PS !cE APP icaon Notes AvaabIe Overview The Signature Series Model SIGA-PS Intelligent Photoelectric Smoke Detector gathers analog information from its smoke sens- ing element and converts it into digital signals. The detector's on-board microprocessor measures and analyzes these signals. It compares the information to historical readings and time patterns to make an alarm decision. Digital filters remove signal patterns that are not typical of fires. Unwanted alarms are virtually elimi- nated. The microprocessor in each detector provides four additional ben- efits - Self-diagnostics and History Log, Automatic Device Map- ping, Stand-alone Operation and Fast, Stable Communication. Self-diagnostics and History Log - Each Signature Series detector constantly runs self-checks to provide important mainte- nance information. The results of the self-check are automatically updated and permanently stored in the detector's non-volatile memory Automatic Device Mapping - The loop controller learns where each device's serial number address is installed relative to other devices on the circuit. The mapping feature provides supervision of each device's installed location to prevent a detector from being reinstalled (after cleaning etc.) in a different location from where it was originally. Stand-alone Operation - A decentralized alarm decision by the detector is guaranteed. On-board intelligence permits the detector to operate in stand-alone mode. If loop controller CPU communi- cations fail for more than four seconds, all devices on that circuit go into stand-alone mode. The circuit acts like a conventional alarm receiving circuit. Fast Stable Communication - On-board intelligence means less information needs to be sent between the detector and the loop controller. Other than regular supervisory polling response, the detector only needs to communicate with the loop controller when it has something new to report. Standard Features Integral microprocessor Non-volatile memory Automatic mapping device Electronic addressing Environmental compensation Intelligent detector Wide 0.67% to 3.77%/ft. sensitivity range Twenty pre-alarm sensitivity values, set in 5% increments Identification of dirty or defective detectors Automatic day/night sensitivity adjustment Twin RED/GREEN status LEDs Standard, relay, fault isolator, and audible mounting bases Designed and manufactured to ISO 9001 standards Page lot 4 .. 85001-0269 Issue 6 Installation Signature Series detectors mount to North American 1-gang boxes, 3-1/2 inch or 4 inch octagon boxes, and to 4 inch square electrical boxes 1-1/2 inches (38 mm) deep. They mount to Euro- pean BESA and 1-gang boxes with 60.3 mm fixing centers. ) J ON (20 mm) 2.0'(61 mm) I- 4.4 (112 mm) Tamper-Resist Lever Arm - Break off to disable - (Located on Base) .. - Access Slot for Tamper-Resist Mechanism / iv— 901 Testing & Maintenance Each detector automatically identifies when it is dirty or defective and causes a "dirty detector" message. The detector's sensitiv- ity measurement can also be transmitted to the loop controller. A sensitivity report can be printed to satisfy NFPA sensitivity meas- urements which must be conducted at the end of the first year and every two years thereafter. The user-friendly maintenance program shows the current state of each detector and other pertinent messages. Single detectors may be turned off temporarily from the control panel. Availability of maintenance features is dependent on the fire alarm system used. Scheduled maintenance (Regular or Selected) for proper detec- tor operation should be planned to meet the requirements of the Authority Having Jurisdiction (AHJ). Refer to current NFPA 72 and ULC CAN/ULC 536 standards. Compatibility The SIGA-PS detectors are compatible only with the Signature Loop Controller. Warnings & Cautions This detector will not operate without electrical power. As fires fre- quently cause power interruption, we suggest you discuss further safeguards with your fire protection specialist. This detector will NOT sense fires that start in areas where smoke cannot reach the detector. Smoke from fires in walls, roofs, or on the opposite side of closed doors may not reach the detector to alarm it. Accessories All detector mounting bases have wiring terminals that are acces- sible from the "room-side" after mounting the base to the electri- cal box. The bases mount to North American 1-gang boxes and to 3½ inch or 4 inch octagon boxes, 1½ inches (38 mm) deep. They also mount to European BESA and 1-gang boxes with 60.3 mm fixing centers. The SIGA-SB4, SIGA-RB4, and SlGA-1134 mount to North American 4 inch sq. electrical boxes in addition to the above boxes. They include the SIGA-TS4 Trim Skirt which is used to cover the "mounting ears" on the base. The SIGA-AB4G mounts to a 4" sqare box only. SIGA-AB4G SIGA-SB SIGA-IB SIGA-RB SIGA-LED Audible Base Standard Base Isolator Base Relay Base Remote LED Standard Base SIGA-SB, SIGA-SB4 - This is the basic mount- ing base for Edwards Signature Series detectors. The SIGA-LED Remote LED is supported by the Standard Base. Relay Base SIGA-RB, SIGA-RB4 - This base includes a relay. Normally open or closed operation is selected during installation. The dry contact is rated for 1 amp (pilot duty) @30 Vdc. The relay's position is supervised to avoid accidentally jarring it out of position. The SIGA-RB can be operated as a control relay if programmed to do so at the control panel (EST3 V.2 only). The relay base does not support the SIGA-LED Remote LED. Audible Base SIGA-AB4G - This base is designed for use where localized or group alarm signaling is required. When the detector senses an alarm condition, the audible base emits a local alarm signal. The optional SIGA-CRR Polarity Reversal Relay can be used for sounding to other audible bases on the same 24 Vdc circuit. Relay and Audible Bases operate as follows: - at system power-up or reset, the relay is de-energized - when a detector is installed in the base with the power on, the relay energizes for four seconds, then de-energizes - when a detector is removed from a base with the power on, the relay is de-energized - when the detector enters the alarm state, the relay is energized. Isolator Base SIGA-IB, SIGA-1B4 - This base includes a built-in line fault isolator for use on Class A circuits. A detector must be installed for it to operate. The isolator base does not support the SIGA-LED Remote LED. The isolator operates as follows: - a short on the line causes all isolators to open within 23 msec - at 10 msec intervals, beginning on one side of the Class A circuit nearest the loop controller, the isolators close to provide the next isolator down the line with power - when the isolator next to the short closes, reopens within 10 msec. The process repeats beginning on the other side of the loop controller. Remote LED SIGA-LED - The remote LED connects to the SIGA-SB or SIGA-SB4 Standard Base only. It features a North American size 1-gang plastic faceplate with a white finish and red alarm LED. SIGA-TS4 Trim Skirt - Supplied with 4 inch bases, it can also be ordered separately to use with the other bases to help hide surface imperfections not covered by the smaller bases. Page 2014 85001-0269 - - '- Issue Term Description 1 Not Used 2 DATA IN/OUT 3 DATA IN (-) 4 Not Used 5 Not Used 6 DATA OUT 7 Not Used OUT (-) Application Although photoelectric detectors have a wide range of fire sensing capabilities they are best suited for detecting slow, smoldering fires. The table below shows six standard test fires used to rate the sensitivity of smoke and heat detectors. The table indicates that no single sensing element is suited for all test fires. Edwards recommends that this detector be installed according to latest recognized edition of national and local fire alarm codes. SIGA-HRS and SIGA-HFS Rate-of- SIGA-PHS SIGA-IPHS Test Fire SIGA-IS Ion SIGA-PS Photo Rise! Fixed Temp. Photo Heat 3D Ion/Photo/Heat 4D Open Wood optimum unsuitable optimum very suitable optimum Wood Pyrolysis suitable optimum unsuitable optimum optimum Smouldering Cotton very suitable optimum unsuitable optimum optimum Poly Urethane Foam very suitable very suitable suitable very suitable optimum n-Heptane optimum very suitable very suitable optimum optimum Liquid Fire without unsuitable unsuitable optimum very suitable very suitable Smoke Typical Wiring The detector mounting bases accept #18 AWG (0.75mm2), #16 (1.0mm2), #14 AWG (1.5mm2), and #12 AWG (2.5mm2) wire sizes. Note: Sizes #16 AWG (1.0mm2) and #18 AWG (0.75mm2) are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wing requirement specifications. Standard Detector Base, SIGA-SB, SIGA-SB4 Relay Detector Base, SIGA-RB, SIGA-RB4 Remote LED F ox resistance per wire ust not exceed 10 Ohms Term Description 1 Not Used 2 DATA IN/OUT (.1-) 3 Not Used 4 DATA IN (-) 5 Remote LED C-) 6 Remote LED (+) 7 Not Used 8 DATA OUT (-) DAT DAT, e. ,.,.j From Signature controller or Previous Device Term Description 1 Normally Open 2 DATA IN/OUT (i-) 3 Common 4 DATA IN (-) 5 Not Used 6 Normally-Closed 7 DATA OUT (-) CONTACT RATING 1.0 Amp @30 VDC (-) (Pilot Duty) (4) To Next Device DATA IN I-I &,OuTl-1 DATA IN 1+1 DATA OUT 1+1 From Signature Controller To Next Device or Previous Device Isolator Detector Base, SIGA-IB, SIGA-1B4 Audible Detector Base, SIGA-AB4G OUT (+) To Next Device DA1,- 11Mv' From Signature Controller or Previous Device Default = High volume Volume settin9j// Cut for low volume 24 Vdc in From power supply or previous base Detain - From Signature controller or previous device + '.4 Tone setting N Default o Temporal pattern (ID I Cut for steady tone To conS gure output volume or tone, cut the circuit board as shown. 24 Vdc Out To next base or EOL relay Data Out To next Signature device Page 3o14 - - i 85001-0269 Issue 6 Specifications ¶EDJVA4R DS Sensing Element Photoelectric - Light Scattering Principle A trrc Fire & Security Company Storage & Operating Air Velocity Range: 0 to 5,000 ft/mm (0 to 25.39 m/s); Humidity: 0 to Environment 93% RH, Non-Condensing Operating Temp: 32°F to 120°F (0°C to Detection & alarm since 1872 49°C); Storage Temp: -4°F to 140°F (-200Cto 60°C) Sensitivity Range ULI/ULC - 0.67%t03.77% obscuratiorVfoot user seiectecl PJarm Most Sensitive: 1 .0%/fl.; More Sensitive: 2.0%/ft.; Normal: 2.5%/ft.; Sensitivity Settings Less Sensitive: 3.0%/ft.; Least Sensitive: 3.5%/ft. Pre-alarm Sensitivity 5% increments, allowinq up to 20 pre-alarm settinas Operating voltage 15.2 to 19.95 Vdc (19 Vdc nominal) Operating Current Quiescent: 45pA @ 19 V; Alarm: 45pA © 19 V Emergency Stand-alone Alarm Mode: iBmA Pulse Current: 100 pA (100 msec); During Com- munication: 9 mA max. Construction & Finish High Impact Engineering Polymer - White Compatible Mounting SIGA-SB Standard Base, SIGA-RB Relay Base, SIGA-IB Isolator Base, Bases SIGA-AB4, SIGA-AB4G Audible Bases LED Operation On-board Green LED - Flashes when polled; On-board Red LED - Flashes when in alarm Both LEDs - Glow steady when in alarm (stand- alone) Compatible Remote Red LED (model SIGA-LED) Flashes when in alarm Compatibility Use With: SIGNATURE Loop Controller Address Requirements Uses one Device Address Agency Listings UL, ULC, MEA, CSFM UL Listed Spacinq 30 ft Ordering Information Catalog Description Ship Wt. Number We (kg) SIGA-PS Intelligent Photoelectric Detector - UL/ULC Listed 0.5 (.23) Accessories SIGA-SB Detector U.S. T 888-378-2329 F 866-503-3996 Canada Chubb Edwards T 519 376 2430 F 519 376 7258 Southeast Asia T:+65 6391 9300 F: +65 6391 9306 India T: +9180 4344 2000 F: +9180 4344 2050 Australia T +613 9239 1200 F +613 9239 1299 Europe T+32272511 20 F+322721 8613 Latin America T 305 593 4301 F 305 593 4300 utcfireandsecufltycom © 2010 UTC Fire & Security. All rights reserved. c/w SIGA-TS4 Trim SIGA-RB Detector Mounting Base wlRelay SIGA-RB4 4-inch Detector Mounting Base w/Relay, c/w SIGA-TS4 Trim Skirt 0.2 (.09) SIGA-IB Detector Mounting Base w/Fault Isolator SIGA-lB4 4-inch Detector Mounting Base w/ Fault Isolator, c/w SIGA-TS4 Trim Skirt SIGA-LED Remote Alarm LED Trim Skirt with 0 P Page 4ot4 -, -E C 85001-0269 I I on pr Issue CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-1657:0126 Page 1 of I CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models SIGA-PS and SIGA-PHS photoelectric smoke detectors. Model SIGA-PHS employs an integral 135°F fixed temperature heat sensor. This heat sensor is a supplementary device to the smoke detector and is not approved as a required heat detector. Refer to listee's printed data sheet for additional detailed product description, installation and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with listee's listed fire alarm control units and Model SIGA Series bases (CSFM Listing No. 7300-1657:120). Model SlGA-PS may be suitable for installation directly in the duct with the velocity range from 0-5000 feet/mm. NOTE: Model SIGA-PHS is not intended for use in lieu of a required heat detector. Formerly 7272-1591:126 and 7272-1388:186 7-29-10 ma This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Standard Features Provides one no/nc contact (SIGA-CR/MCR) Form "C" dry relay contact can be used to control external ap- pliances such as door closers, fans, dampers etc. Allows group operation of sounder bases The SIGA-CRR/MCRR reverses the polarity of its 24 Vdc out- put, thus activating all Sounder Bases on the data loop. Plug-in (UIO) or standard 1-gang mount UIO versions allow quick installation where multiple modules are required. The 1-gang mount version is ideal for remote locations that require a single module. Automatic device mapping Signature modules transmit information to the loop controller regarding their circuit locations with respect to other Signature devices on the wire loop. Electronic addressing Programmable addresses are downloaded from the loop con- troller, a PC, or the SIGA-PRO Signature Program/Service Tool; there are no switches or dials to set. Intelligent device with microprocessor Jl decisions are made at the module to allow lower com- munication speed with substantially improved control panel response time and less sensitivity to line noise and loop wiring properties; twisted or shielded wire is not required. Ground fault detection by address Detects ground faults right down to the device level. .:.:I. t ON - - ••LSIGA-CR SIG Intelligent Input/Output T TM Liie Safety & Communications Control Relay Modules SIGA-CR, SIGA-MCR, SIGA- CRR, SIGA-MCRR Overview The Control Relay Module and the Polarity Reversal Relay Module are part of the Signature Series system. They are intelligent analog addressable devices available in either plug-in (UIO) versions, or standard 1-gang mount versions. The SIGA-CR/MCR Control Relay Module provides a Form 'C' dry relay contact to control external appliances such as door clos- ers, fans, dampers etc. This device does not provide supervision of the state of the relay contact. Instead, the on-board micro- processor ensures that the relay is in the proper ON/OFF state. Upon command from the loop controller, the SIGA-CR/MCR relay activates the normally open or normally-closed contact. The SIGA-CRR/MCRR Polarity Reversal Relay Module provides a Form "C" dry relay contact to power and activate a series of SIGA-AB4G Audible Sounder Bases. Upon command from the Signature loop controller, the SlGA-CRR reverses the polarity of its 24 Vdc output, thus activating all Sounder Bases on the data loop. Standard-mount versions (SIGA-CR and SIGA-CRR) are installed to standard North American 1-gang electrical boxes, making them ideal for locations where only one module is re- quired. Separate I/O and data loop connections are made to each module. Plug-in UIO versions (SIGA-MCR and SIGA-MCRR) are part of the UIO family of plug-in Signature Series modules. They func- tion identically to the standard mount versions, but take advantage of the modular flexibility and easy installation that characterizes all UIO modules. Two- and six-module UIO motherboards are available. All wiring connections are made to terminal blocks on the motherboard. UIO assemblies may be mounted in Edwards enclosures. Page lof6 85001-0239 .0! t '. t Issue 7.2 Installation SIGA-CR and SIGA-CRR: modules mount to North American 21h inch (64 mm) deep 1-gang boxes and 1½ inch (38 mm) deep 4 inch square boxes with 1-gang covers and SIGA-MP mounting plates. The terminals are suited for #12 to #18 AWG (2.5 mm2 to 0.75 mm2) wire size. Compatible electrical box Wall plate, white (1-gang) Application The operation of Signature Series control relays is determined by their sub-type code or "Personality Code." Personality Code 8: CONTROL RELAY (SIGA-CR/MCR) - Dry Contact Output. This setting configures the module to provide one Form C" DRY RELAY CONTACT to control Door Closers, Fans, Dampers, etc. Contact rating is 2.0 amp © 24 Vdc; 0.5 amp © 120 Vac (or 220 Vac for non-UL applications). Personality Code 8 is assigned at the factory. No user configuration is re- quired. Personality Code 8: POLARITY REVERSAL RELAY MODULE (SIGA-CRR/MCRR). This setting configures the module to re- verse the polarity of its 24 Vdc output. Contact rating is 2.0 amp @ 24 Vdc (pilot duty). Personality Code 8 is assigned at the factory. No user configuration is required. '\r °.• Compatibility [1L. The Signature Series modules are compatible only with EST's Signature Loop Controller. LED viewing parts-4--l-,, 00 SIGA-MCR and SIGA-MCRR: mount the UlO motherboard inside a suitable Edwards enclosure with screws and wash- ers provided. Plug the module into any available position on the motherboard and secure the module to the motherboard with the captive screws. Wiring connections are made to the terminals on the motherboard (see wiring diagram). UlO motherboard terminals are suited for #12 to #18 AWG (2.5 mm2 to 0.75 mm) wire size. UIO Motherboard 1 6-32 if Self-tapping screws screws Module #6 Flat washers —Cabinet or electrIcal enclosure Warnings & Cautions This module will not operate without electrical power. As fires fre- quently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. Testing & Maintenance The module's automatic self-diagnosis identifies when it is defec- tive and causes a trouble message. The user-friendly maintenance program shows the current state of each module and other per- tinent messages. Single modules may be turned off (deactivated) temporarily, from the control panel. Availability of maintenance features is dependent on the fire alarm system used. Scheduled maintenance (Regular or Selected) for proper system operation should be planned to meet the requirements of the Authority Hav- ing Jurisdiction (AHJ). Refer to current NFPA 72 and ULC CAN/ ULC 536 standards. Electronic Addressing - The loop controller electronically ad- dresses each module, saving valuable time during system com- missioning. Setting complicated switches or dials is not required. Each module has its own unique serial number stored in its on- board memory. The loop controller identifies each device on the loop and assigns a "soft" address to each serial number. If desired, the modules can be addressed using the SIGA-PRO Signature Program/Service Tool. Edwards recommends that this module be installed according to latest recognized edition of national and local fire alarm codes. Page 2ol6 ' TA s r F 85001-0239 - - - f Issue 7.2 Typical Wiring Modules will accept #18 AWG (0.75mm2), #16 (1.0mm2), #14 AWG (1.50mm2) and #12 AWG (2.5mm2) wire sizes. Note: Sizes #16 AWG (1 .omm2) and #18 AWG (0.75mm2) are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Normally- Normally- Open Common Closed LJ IF TB2 876 . (Alarm/Active) © © Green LED Red LED 4321 (Normal) II mi kIrtiiYi1 I Notes \ Refer to Signature Loop Controller Installation Sheet for wiring specifications. NFPA 72 requires that the SIGA-CR/SIGA-MCR be installed in the same room as the device it is control- ling. This requirement may not apply in all markets. Check with your local AHJ for details. The SIGA-U106R and the SIGA-U102R do not come with TB 14. The SiGA-U106 does not come with TB8 through TB13. z Supervised and power-limited. If the source is nonpower-limited, maintain a space of 1/4 inch from power-limited wiring or use FPL, FPLP, FPLR, or an equivalent in accordance with the National Electrical Code. 7) Maximum #12 AWG (2.5mm2) wire. Mm. #18 (0.75mm2). f DATA IN (+) 1 DATA IN (-) From Signature Controller or Previous Device DATA OUT (+) DATA oui (-) To Next Device SIGA-CR Control Relay Normally Open Common Normally Closed 1234 Data ln]_____ 02 02 +J 1 TB7JM TB14 Data J F 0 z 'n -u . TB15 S. 123 Green LED (Normal) Red LED (Active) No connections required for MCR. Other modules may require connections. No connections required for MCR. Other modules may require connections. SIGA-MCR Control Relay Page 30f6 , , 85001-0239 . t -. r' Issue 7.2 Typical Wiring Modules will accept #18 AWG (0.75mm2), #16(1 .0mm2), #14 AWG (1 .50mm2) and #12 AWG (2.50mm2) wire sizes. Note: Sizes #16 AWG (1.0mm2) and #18 AWG (0.75mm2) are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. AB4G AB4G AB4G Audible Base Audible Base Audible Base Listed 24 VOC Nominal Powe Suppl Signature Controller I IJWI II IbII sounder base SIGA-MCRR SIGA-CRR Schematic SlGA-MCRR Schematic Power In Power Out Polarity reverses — + when activated. I. Audible = reguired for EOL Relay + Bases supevision Wmm Notes \ Refer to the Signature controller installation sheet for wiring. One Pair of Wires (24 Vdc power). One Pair of Wires (Signature Data). A4 SIngle Wire (24 Vdc power). The SIGA-ul06R and the SIGA-UI02R do not come with TB14. The SIGA-U106 does not come with TB8 through TB13. A Supervised and power-limited. 8 If the source is noripower-limited, maintain a space of 1/4 inch from power-limited wiring or use FPL, FPLP. FPLR, or an equivalent in accordance with the National Electrical Code. 9 Maximum #12 AWG (2.5mm2) wire; Minimum #18 AWG (0.75mm2). 10 End-of-Une Relay must monitor and report power supply trouble to control panel. 11 Class B Data wiring may be "T-tapped. Signature — Data Data Out Circuit + 24Vdcpower —, ___ UL/ULC Listed _fI supply or 1234 1234 14, N Red LED Activel connections No required for MCRR. Other modules may S. require Connections No connections required for MCRR. Other modules may require connections. Date Out + 5ignatu 4 Circuit Date t Data In Green LED lNormall Red LED lActivel Optional MCRR or MCR for disabling/disconnecting en oudible base. *43~2 1 CT' For Geeral Fire Alorm Operation For normal operation MCRR - U101Rl series motherboard No connections required for MCRR. Other modules may require connections. Page 4of6 r. - - r 85001-0239 - t Issue 7.2 Specifications Catalog Number SIGA-CR SIGA-MCR SIGA-CRR SIGA-MCRR Description Control Relay Polarity Reversal Relay Type Code Personality Code 8 (Factory Set) Personality Code 8 (Factory Set) Address Requirements Uses 1 Module Address Operating Current Standby = lOOpA Activated = lOOpA Operating Voltage 15.2 to 19.95 Vdc (19 Vdc nominal) Relay Type and Rating Form C" 24 VDC =2 amps (pilot duty) 120 Vac = 0.5 amps 220 Vac (non-UL) = 0.5 amps Mounting North American 21h inch (64 mm) deep 1-gang boxes and 1½ inch (38 mm) deep 4 inch square boxes with 1-gang covers and SIGA- MP mounting plates Plugs into U102R, U106R or U106 Motherboards North American 21h inch (64 mm) deep 1-gang boxes and 1½ inch (38 mm) deep 4 inch square boxes with 1-gang covers and SIGA- MP mounting plates Plugs into U102R, U106R or U106 Motherboards Construction & Finish High Impact Engineering Polymer Storage and Operating Environment Operating Temperature: 32°F to 120°F (0°C to 49°C) Storage Temperature: -4°F to 140°F (-20°C to 60°C) Humidity: 0 to 93% RH LED Operation On-board Green LED - Rashes when polled On-board Red LED - Flashes when in alarm/active Compatibility Use With: Signature Loop Controller Agency Listings UL, ULC, CSFM, MEA Ordering Information Catalog Number Description Weight - lbs Ship (kg) SIGA-CR Control Relay Module (Standard Mount) 0.4(0.15) SIGA-MCR Control Relay Module (UIO Mount) 0.18(0.08) SIGA-CRR Polarity Reversal Relay Module (Standard Mount) 0.4(0.15) SlGA-MCRR Polarity Reversal Relay Module (UIO Mount) 0.18(0.08) Related Equipment 27193-11 Surface Mount Box - Red, 1-gang 1(0.6) 27193-16 Surface Mount Box - White, 1-gang 1 (0.6) SIGA-UI02R Universal Input-Output Module Board w/Riser Inputs - Two Module Positions 0.32(0.15) SIGA-Ul06R Universal Input-Output Module Board w/Riser Inputs - Six Module Positions 0.62 (0.28) SlGA-U106 Universal Input-Output Module Board - Six Module Positions 0.56 (0.25) SIGA-AB4G Audible (Sounder) Detector Base 0.3 (0.15) Accessories MFC-A Multifunction Fire Cabinet - Red, supports Signature Module Mounting Plates 7.0 (3.1) SIGA-MB4 Transponder Mounting Bracket (allows for mounting two 1-gang modules in a 2-gang box) 0.4 (0.15) SIGA-MP1 Signature Module Mounting Plate, 1 footprint 1.5 (0.70) SIGA-MP2 Signature Module Mounting Plate, 1/2 footprint 0.5 (0.23) SlGA-MP2L Signature Module Mounting Plate, 1/2 extended footprint 1.02 (0.46) - - Page 5of6 85001-0239 Issue 7.2 Signature Series Overview The Signature Series intelligent analog-addressable system from Edwards is an entire cbwAR DS family of multi-sensor detectors and mounting bases, multiple-function input and output A UTC Fire & Securfty Company modules, network and non-network control panels, and user-friendly maintenance and Detection & alarm since 1872 service tools. Analog information from equipment connected to Signature devices is gathered and converted into digital signals. An onboard microprocessor in each Signature U.S. device measures and analyzes the signal and decides whether or not to input an alarm. T 888-378-2329 The microprocessor in each Signature device provides four additional benefits - Self-di- F 866-503-3996 agnostics and History Log, Automatic Device Mapping, Stand-alone Operation and Fast, Canada Stable Communication. Chubb Edwards 15193762430 Self-diagnostics and History Log - Each Signature Series device constantly runs self- F 519 376 7258 checks to provide important maintenance information. The results of the self-check are Southeast Asia automatically updated and permanently stored in its non-volatile memory. This information T: +65 6391 9300 is accessible for review any time at the control panel, PC, or using the SIGA-PRO Signa- F: +65 6391 9306 ture Program/Service Tool. The information stored in device memory includes: India Device serial number, address, and type T: +9180 4344 2000 Time and date of last alarm F: +9180 4344 2050 Most recent trouble code logged by the detector - 32 possible trouble codes may be Australia used to diagnose faults. 1+61 3 9239 1200 F +61 3 9239 1299 Automatic Device Mapping —The Signature Data Controller (SDC) learns where each Europe device's serial number address is installed relative to other devices on the circuit. The 1+322 72511 20 SDC keeps a map of all Signature Series devices connected to it. The Signature Series F +322721 8613 Data Entry Program also uses the mapping feature. With interactive menus and graphic support, the wired circuits between each device can be examined. Layout or "as-built" Latin America T 305 593 4301 drawing information showing branch wiring (T-taps), device types and their address are F 305 593 4300 stored on disk for printing hard copy. This takes the mystery out of the installation. The preparation of as-built drawings is fast and efficient. utCfireandsecuIitCom Device mapping allows the Signature Data Controller to discover: © 2010 UTC File & Secunty. All rights reserved. Unexpected additional device addresses Missing device addresses Changes to the wiring in the circuit. Most Signature modules use a personality code selected by the installer to determine their actual function. Personality codes are downloaded from the SDC during system configu- ration and are indicated during device mapping. Standalone Operation - A decentralized alarm decision by the device is guaranteed. Onboard intelligence permits the device to operate in standalone (degrade) mode. If Sig- nature loop controller CPU communications fall for more than four seconds, all devices on that circuit go into standalone mode. The circuit acts like a conventional alarm receiving circuit. Each Signature device on the circuit continues to collect and analyze information from its slave devices. When connected to a panel utilizing standalone operation, modules with their 'personality" set as alarm devices (lDC) will alarm should their slave alarm-initiat- ing device activate. Page 6 of 6 P T 85001-0239 .r' Issue 7.2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL Im FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1657:0121 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, lnc.8985 Town Center Parkway, Bradenton, 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models SIGA-CCI, SIGA-CC2, SIGA-CTI, SIGA-CTIHT, SIGA-CT2, SIGA-CR, SIGA-CRR, SIGA-UM, SIGA-MMI, SIGA-WTM, SIGA-IM, SIGA-MDM, SIGA-MAB, SIGA-MCT2, SIGA-MCCI SIGA-MCC2, SIGA-MCR and SIGA-MCRR remote transponders. Models SIGA-AA30 and SIGA-AA50 audio amplifiers. Models SIGA-APS and SIGA-APS-220 power supplies. Models SIGA-MB4, SIGA-MPI, SIGA-MP2 and SIGA-MP2L mounting plates. Models SIGA-UI02R, SIGA-U106 and SlGA-U106R motherboards. Model CS-SIGA-CCIP releasing module. Models SIGA-CCIS and SIGA-MCCIS Auto-Sync Output Modules. Models MFC-A and MFC-AD Enclosures. Model SlGA-CR2 Control Relay Module. Model SIGA-CTI HI; Signature Series High Temperature Single Input Module. *SIGA..CRH High Power Control Relay Module. Refer to listee's data sheet for additional detailed product description and operational consideration. RATING: 15.2- 19.95 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7300-1591:121 and 7300-1388:178 *Rev 01-11-16 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division 310 South Union Street Sales 800.888.5538 [Devices, Functional Devices, Inc. Office 765.883.5538 net 1B Russiaville, IN 46979 Fax 765.883.7505 I flC.j j! www.FunctionalDevices.com Email sales@FunctionalDevices.com P 10 Amp Pilot Control Relays RIBUIC Enclosed Relay 10 Amp SPOT with 10-30Vac/dcl 120 Vac Coil Wiit/5k Mu 00ac N/C Wht/Elu Yd 10-300orIdc Comm Whtflel T 0"Comm I RIBHIC Enclosed Relay 10 Amp SPOT with 10-30Vac/dcl 208-277 Vac Coil Wilt/Om Blu 2W277 Vic N/C Wirt/Olu Yd 10•30Vac/dc Comm Wbt/YoI I Org Comm I 0/0 IR RIBHIC-RD RIBH1C-N4 Red housing NEMA 4X housing RlBU1C-RD RIBU1C-N4 SPECIFICATIONS # Relays & Contact Type: One (1) SPOT Continuous Duty Coil Contact Ratings: Coil Current: Expected Relay Life: 10 million cycles minimum mechanical 10 Amp Resistive @ 277 Vac 33 mA @ 10 Vac 13 mA @ 10 Vdc Operating Temperature: -3010140°F 10 Amp Resistive @ 28 Vdc 35 mA @ 12 Vac 15 mA © 12 Vdc Operate Time: 20mS 480 VA Pilot Duty © 240-277 Vac 46 mA © 24 Vac 18 mA © 24 Vdc Relay Status: LED On = Activated 480 VA Ballast © 277 Vac 55 mA @ 30 Vac 20 mA © 30 Vdc Dimensions: 1.70'x 2.80-x 1.50" with .50"NPT nipple 600 Watt Tungsten © 120 Vac N/O 28 mA © 120 Vac (RIBU1 C) Wires: 16', 600V Rated 240 Watt Tungsten © 120 Vac N/C 39 mA @ 208-277 Vac (RIBH1C) Approvals: UL Listed, UL916, 1.11-864, C-UL 1/3 HP for WO © 120-240 Vac Coil Voltage Input: California State Fire Marshal, CE, RoHS Housing Rating: Plenum, NEMA 1 1/6 HP for N/C © 120-240 Vac 1/4 HP for N/O @ 277 Vac 10-30 Vac/dc ; 120 Vac; 50-60 Hz (RIBU1 C) Gold Flash: Yes 1/8 HP for N/C © 277 Vac 10-30 Vac/dc ; 208-277 Vac 50-60 Hz (RIBH1C) Override Switch: No Drop Out = 2.1 Vac / 2.8 Vdc Pull In =9 Vac /1OVdc Notes CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL LISTING SERVICE FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM IN LISTING No. 7300-1555:0100 Page 1 of 2 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: FUNCTIONAL DEVICES, INC.101 Commerce Dr., P0 Box 437, Sharpsville, IN 46068 Contact: Dana Huntzinger (765) 883-5538 Fax (765) 883-4262 Email: d.huntzingerfunctionaldevices.com DESIGN: Models RIBUIC, RIBU2C, RIBL3C, RIBL4C, RIBHIC, RIBH2C, RIBTUIC, RIBTU2C, RIBTHIC, RIBTH2C, RIBXLCF, RIBXLCA, RIBXLCRF, RIBXLCRA, RIBXLCV, RIBXLCRV, RIBXLCJF, RIBXLCJA, RIBXLCJV, RIBUICW, RIBHICW, RIBMUIC, RIBMU2C, RIBMHIC, RIBMNUIC, RIBMNHIC, RIBUIS, RIBU2S2, RIBU2SC, RIBUISM, RIBHIS, RIBHISM, RIBTUI S, RIBTHI 5, RIBUI SC, RIBH1 SC, RIBTUISC, RIBTHI SC, RIBU1 S-250, RIBU2SC-250, RIBU2S2-250, RIBUI SM-250, RIBHI S-250, RIBH1 SM-250, RIBTU I S-250, RIBTHIS-250, RIBMUI 5, RIBMHI S, RIBMUI SM, RIBMHI SM, RIBMUI SC, RIBMH1SC, RIBMNUIS, RIBMNHIS, RIBMNU1SM, RIBMNHISM, RIBMUIS-250, RIBMHIS-250, RIBMU 1 SM-250, RIBMH ISM-250, RIBXLSF, RIBXLSA, RIBXLSRF, RIBXLSRA, RIBXLSV, RIBXLSRV, RIBXLSJF, RIBXLSJA, RIBXLSJV, RIBXLSF-250, RIBXLSA-250, RIBXLSRF-250, RIBXLSRA-250, RIBXLSV-250, RIBXLSRV-250, RIBXLSJA-250, RIBXLSJF-250, RIBXLSJV-250, RIBXLCEA, RIBXLCEF, RIBXLSEA, RIBXLSEF, RIBXLCEV, RIBXLSEV, RIBXLSEA-250, RIBXLSEF-250, RIBXLSEV-250, RIB24C, RI13240IC, R1132402C, RIB24S, RIB240IS, R11324025, RIBI2C, RIBI2S, RI13I20IC, RI13I202C, RI13I20IS, RIBI202S, RIBM24C, RIBM24S, RIBMN24C, RIBMN24S, RIBMI2C, RIBMI2S, R1BMN12C, RIBMN12S, RIBM240I C, RIBM2402C, RIBM240IS, RIBM2402S, R113241), R1B2401 D, R1B2402D, RIBM24D, RIBMN24D, RIBM240I1), RIBMN240ID, RIBM2402D, RIBMN2402D, RIBT2413, RIBT240I13, RIBT240213, RIBT24213, RIBT24313, RI132413, RI13240I13, R1B2402B, R1B242B, RIBT24SB, RIBT240I SB, RlBT2402SB, RIBT24SBC, R1BT2401 SBC, RIBT2402SBC, RI1324SBC, RIB240ISBC, RIB2402SBC, RIBX2413F, RIBX24BA, RIBX24SBF, RIBX24SBA, RIBX24BV, RIBX24SBV, RIBM24B, RIBM240113, RlBM240213, RIBMX24BA, RIBMX24BF, RIBM24SB, RIBM24SBC, RIBM240I SB, RIBM2402SB, RIBM240I SBC, RIBM2402SBC, RIBMX24SBA, RIBMX24SBF, RIBMX24BV, RIBMX24SBV, RIBMX24BEA, RIBMX24BEF, RIBMX24SBEA, RIBMX24SBEF, RIBMX24BEV, RIBMX24SBEV, RIB24P, RIBT24P, RIBOIP, RIB02P, RIB04P, RIBM24PL, RIBMN24PL, RIB24Z, RIBT24Z, RIBM24ZL, R1B24P30, R1B24S2, RIBX243PA, RIBX243PF, RIBX243PV, R18243P, RIBT243P, RIB0I3P, RIB023P, RIB043P, RIBXF, RIBXA, RIBXV, RIBXRF, RIBXRA, RIBXRV, RIBXJF, RIBXJA, RIBXJV, RIBXEA, RIBXEF, RIBXEV, RIBMXA, RIBMXF, RIBMXV, RIBMXRA, RIBMXRF, RIBMXRV, RIBMXJA, RIBMXJF, RIBMXJV, RIBMXEA, RIBMXEF, RIBMXEV, RIBUIC-N4, RIBMH2C, RIB24SD, RIB24SDC, RlBT24D, RIBT24SD, R1BT24010, RIBT2402D, R1B2401 SD, RIB2402SD, RIB240ISDC, RIBT240I SD, RIBT2401 SDC, RIBT2402SDC, R1132401 SB, RIB2402SB, R1B2401 SBM, RIB2402SBM, RIBT240I SBM, RIBT2402SBM, RIBM240ISBM, RIBM2402SBM, RI130IS2, RI1302S2, R11304S2, RIB0IP30, RIB02P30, RIB04P30, RIBM24ZN, RIBM243PN, RIBMOI 3PN, RIBM023PN, RIBM043PN, RIBTELC, *Revised 05-31-12 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed \ the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7300-1555:0100 Page 2 of 2 RIBTELS, RIBTE2413, RIBTE24SB, RIBTEOIB, RIBTE0213, RIBTEOISB, RIBTE24P, RIBTEOIP, RIBTE02P, RIBME240I13, RIBME01P, RIBME02P, RIBME240IP, R1BME2401 SB, RIBME240213, RIBME24P, RIBME2402P, RIBME24SB, RIBME2402SB, RIBI 2C-FA, R1B24C-FA, R1B24P-FA, R1B245-FA, RIBMNI 2C-FA, RIBMNI 2S-FA, R1BMN24C-FA, RIBMN24S-FA, RIBT24B-FA, R11321 CDC, RIBOI BDC, RIB02BDC, RIBT2413-EXT, R1B124213-EXT, R1132413-EXT, R11324213-EXT, R1B124SB-EXT, R1B245B-EXT, R16T24SBC-EXT, R1B245BC-EXT, R1B242SB-EXT, RIBOIB, RIBOISB, RIBOISBC, R11310213, R11302SB, RI1302SBC, RI132402SDC, R1132421C, R11324215, R1132425B, R113245B, RIBD242IC, RIBD242IS, RIBL1C-DC, RIBMOIB, RIBMOISB, RIBM01SBC, RIBM0213, RIBM02SB, RIBM02SBC, RIBM120IC, R1BM12015, RIBMI202C, RIBMI202S, RIBM240IP, R1BM2401Z, R1BM2402P, RIBM2402Z, R1BM2421 C, R1BM24215, RIBMD242I C, R1BMD2421 S, RIBMEOIZ, RIBME02Z, RIBME04P, R1BME2401 Z, R1BME2402Z, RIBME2413, RIBME24Z, R1BMN2421 C, RIBMN242IS, RIBTOIB, R113101S2, RIBT01SB, RIBTOISBC, RIBT0213, R1BT0252, RIBT02SB, RIBT02SBC, R1BT04S2, RIBT240IP, RIBT240IZ, R1BT2402P, RIBT2402SD, R1BT2402Z, R1BT24S2, RIBTD242I C, R1BTD2421 S, RIBTEOI S2, RIBTEOI SBC, RIBTEOIZ, RIBTE02S2, RIBTE02SB, RIBTE02SBC, RIBTE02Z, RIBTE04P, RIBTE04S2, RIBTE2401 P, RIBTE240I Z, RIBTE2402P, R1BTE2402Z, R1BTE24S2, R1BTE24Z, RIBTU2SC, RIBXG420*(b), RIBXGA, RIBXGF, RIBXGT420*(b), RIBXGTA, RIBXGTF, RIBXGTV*(a), RIBXGV*(a), RIBXK420*(b), RIBXKA, RIBXKF, RIBXKT420(b), RIBXKTA, RIBXKTF, RIBXKTV*(a), RIBXK\P(a), RIBMNLB, *R1B24218 *R1B2421 SB, *RIBMN24ZL *RIBMHI SC-250, *RIBMNHI S-250, *RIBMNHISM..250 *RIBMNUI S-250, *RIBMNU1 SM-250, *RlBMU1 SC-250, *Rl BTH I SC-250, *RIBTUI SC-250, *RIBU1 SC-250, *RIBXGFL *RIBXGHA *RIBXGHF *RIBXGHTA, *RIBXGHTF, *RIBXGTFL, *RIBLB *relay modules. - may be followed by up to 2 alpha-numeric characters designating voltage output range, may be followed by up to 3 alpha-numeric characters designating current input range. - may be followed by up to 3 alpha-numeric characters designating current input range)relay modules. These devices are intended for use with external dedicated smoke control systems or general signal equipment. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as relay modules for use with separately listed compatible smoke control equipment. The devices shall be provided with polymeric enclosure with integral conduit fining to facilitate connection to a permanent wiring system. Revised 05-31-12 bh . 0 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Strobes, Horns, Bells, Chimes T TM / Life Safety & Communications Field Configurable Ceiling Strobes 141111130 , Genesis Series IRE Pending One or more patents pending. Overview Genesis life safety and mass notification/emergency communica- tions (ECS/MNS) ceiling strobes are small, compact, and attractive visible emergency signaling devices. Protruding no more than 1.6" (41 mm) from the ceiling, Genesis strobes blend with any decor. Thanks to patented breakthrough technology, Edwards Gen- esis strobes do not require bulky specular reflectors and lenses. Instead, an exclusive cavity design conditions light to produce a highly controlled distribution pattern. Significant development efforts employing this new technology have given rise to a new benchmark in strobe performance - FullLight technology. FullLight strobe technology produces a smooth light distribution pattern without the spikes and voids characteristic of specular reflectors. This ensures the entire coverage area receives consis- tent illumination from the strobe flash. As a result, Genesis strobes with FullLight technology go well beyond the minimum UL-required "cross" pattern, significantly exceeding UL-1 971 and ULC-S526 light distribution requirements. Depending on the model, clear lens Genesis ceiling strobes fea- ture 15 to 95, or 95 to 177 candela output (see ordering informa- tion), which is selectable with a conveniently-located switch. The candela output setting remains clearly visible even after final instal- lation, yet it is locked in place to prevent unauthorized movement after installation. Genesis ECS/MNS appliances offer emergency signaling with clear or amber lenses and with optional ALERT housing labels. They are ideal for applications that require differentiation between life safety and mass notification alerts. Standard Features Field configurable - no need to remove the device! - 15/30/75/95 cd and 95/115/150/177 cd clear strobe lens models available - Switch settings remain visible even after the unit is installed ECS/MNS models available - 13/26/65/82 and 82/100/130/155 (1971 equivalent) amber lens models available Unique low-profile design - 30 per cent slimmer profile than comparable signals - Attractive appearance - No visible mounting screws - Available with white or red housings Easy to install - Fits all standard 4" square electrical boxes with plenty of room behind the signal for extra wire - no extension ring or trim plate needed - #18 to #12 AWG terminals - ideal for long runs or existing wiring Unparalleled performance - Exclusive FullLight strobe technology produces the industry's most even light distribution - Precision timing electronics meet tough synchronizing standards for strobes - Low current draw minimizes system overhead Approved for public and private mode applications - UL 1971-listed as signaling devices for the hearing impaired - UL 1638-listed as protective visual signaling appliances - ULJULC listed for ceiling or wall use Page 1014 t !'t 85001-0557 Issue 7 Application Genesis strobes are UL 1971 or 1638 listed for indoor use. Prevailing codes require strobes to be used where ambient noise conditions exceed specified levels, where occupants use hearing protection, and in areas of public accommodation. Consult with your Authority Having Jurisdiction for details. All Genesis strobes exceed UL synchronization requirements (within 10 milliseconds over a two-hour period) when used with a synchronization source. Synchronization for multiple strobe lights in a single field of view is required. ECS/MNS Applications Genesis ECS/MNS appliances bring the same high-performance life safety features and unobtrusive design to mass notification applica- tions. Available as standard units with clear or amber lenses with optional ALERT markings, thy are ideal for applications that require differentiation between life safety and ECS/MNS signals. Units are also available (special order) with red, blue or green lenses. Installation All models are intended for indoor applications only. Strobes mount to any flush North-American 4" square electrical box, 21/8 (54 mm) deep. Genesis ceiling strobes simply unlatch and twist to open. This gains access to mounting screws and the selectable candela switch. The shallow depth of Genesis devices leaves ample room behind the signal for extra wiring. Once installed with the cover in place, no mounting screws are visible. Wiring Field wiring terminals accommodate #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wiring. Strobes are interconnected with a single pair of wires as shown below. Dimensions 8.8" dia. (173 mm) 1.0" (25 mm) -S 0.60"(15 mm) Light output (effective cd) Percent of UL rating versus angle - Percentage of rated output - "- Horizontal and vertical outputs reflect the same pattern. Field Configuration Depending on the model, Genesis ceiling speaker-strobes have multi-candela output Candela switch (see ordering information). The output If setting is changed by simply opening the , / device and sliding the switch to the desired / ( setting. The strobe does not have to be ' removed to change the output setting. 7 The setting remains visible through a small Indicator window on the front of the device after the cover is closed. WARNING: These devices will not operatewithout electrical power. AsfiresfrequenfJy cause power interruptions, we suggest you discuss further safeguards with your local fire protection specialist. 90• 1• To listed To next fire alarm appliance, control I I end-of-line panel LIJCIJ LJCIJ I orretumto I control I equipment Page 2of4 - 85001-0557 \Ic' to 1. . ... it. r 'ostr Issue 7 Light output setting, high output models "95" or "D" "115" or "C" "150" or "B" 99177"o'"A" RMS RMS RMS RMS 330 392 502 565 432 518 643 693 Light output setting, high output models U95 or "115" or "150" or "B" 77fl or "A" RMS RMS RMS RMS 333 392 499 551 259 303 378 429 212 245 306 342 155 180 211 236 484 570 673 724 380 438 537 604 318 361 434 484 245 269 308 338 Current Draw Light output switch settings for UL 1971 listed models are selectable by numeric candela value. ECS/MNS appliances are selectable by A, B, C, or D designations. UL Light output setting, standard models 111511 or "D" II3) or 'C" 75II or "B" 9695 or "A" Rating RMS RMS RMS RMS 16 Vdc 109 151 281 318 16Vfwr 131 194 379 437 Typical Current I Light output setting, standard models "15" or "D" "30" or "C', "75" or "B" "95" or "A" RMS RMS RMS RMS 16 Vdc 94 140 273 325 20 Vdc 74 108 205 244 24 Vdc 63 90 168 194 33 Vdc 48 70 124 139 16Vfwr 126 187 368 403 20Vfwr 108 156 281 333 24Vfwr 97 139 240 270 33Vfwr 89 119 197 214 Current values are shown in mA. Specifications Textured UV stabilized, color impregnated engineered plastic. Exceeds 94V-0 UL flammability rating. Red and white models Housing available. Lens Optical grade polycarbonate (clear). Flush mount to North American 4-inch square electrical box, 2-1/8 (54 mm) inches deep. No extension ring required. Mounting Suitable for indoor wail or ceilinci applications. Wire Connections Screw terminals: #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wire size. Operating Voltage Regulated 16 to 33 Vdc, 16 to 33 Vfwr. Ooeratina environment Indoor: 32-120° F (0-49° C) ambient temoerature: 0-93% relative humidity. Meets or exceeds year 2004 UL requirements for standards UL1 638 and 1-11-1 971 and Canadian requirements for Agency listings/approvals standards CAN/ULC S526-02 and CAN/ULC S524-01. All models comply with ADA Code of Federal Regulation Chapter 28 Part 36 Final Rule. CSFM, MEA. FM cendina. Strobe output rating UL 1971, UL 1638, ULC S526: selectable 15/30/75/95 cd (GC-VM) and 95/115/150/177 cd (GC-VMH) GC-VM series strobes: non-c Strobe operating voltage or unfiltered 16-33 Vdc FWR. GC-VM series strobes: one flash per second synchronized with optional G1 M Genesis Signal Master indefinitely within 10 Strobe flash rate milliseconds. Temporal setting (private mode only): synchronized to temporal output of Genesis audible signals on same circuit. Meets or exceeds UL 1971 requirements. Maximum allowed resistance between any two devices is 20 Ohms. Refer Synchronization to specifications for the synchronization control module, this strobe, and the control panel to determine allowed wire resistance. SIGA-CC1 S, SlGA-MCC1 S, SlGA-CC2A, SIGA-MCC2A, G1 M-RM Synchronization Sources BPS6A, BPS1 OA, APS6A, APS1 OA, i064, i0500, Fireshield Plus 3,5 and 10 zone. Add G1 M for G1-CVM &G1 -HDVM devices only. Page 3of4 85001-0557 Issue 7 Ordering Information Light output switch settings for UL 1971 listed models are selectable by numeric candela value. ECS/MNS appliances are selectable by A, B, C, or D designations. Model I Housing I Marking I Lens I Strobe Ship Wt. Life safety Appliances (ciw running man icon screen printed on housing) GC-VM White None Clear Selectable 15, 30, 75,095 Cd 1.8 lb. (0.82 kg.) GCF-VM White FIRE" GCFR-VM Red FIRE" GC-VMH White None Selectable high output 95, 115, 150, or 177 cd GCF-VMH White FIRE" ECS/MNS Appliances (no running man icon on housing) GCWA-VMA White Alert" Amber Selectable A B, C, D 1.8 lb. (0.82 kg.) GCWA-VMC Clear c3CWN-VMA None ______ Amber GCWN-VMC Clear GCWA-VMHA "Alert" Amber Selectable high output A, B, C or D Clear GCWA-VMHC Clear GCWN-VMHA None Amber GCWN-VMHC Units with red, blue or green lenses are available as a special order. Contact customer service for details. A WAR Os A UTC Fire & Security Company Detection & alarm since 1872 U.S. T 888 378 2329 F 866 503 3996 Canada Chubb Edwards T 519 376 2430 F 519 376 7258 Southeast Asia T: +65 6391 9300 F: +65 6391 9306 India T:+91 8043442000 F: +9180 4344 2050 Australia T+61 392391200 F +613 9239 1299 Europe T+32272511 20 F+32272186 13 Latin America T 305 593 4301 F 305 593 4300 utCflraandsecuritycom © 2010 UTC Fire & Security. All rights reserved. Page 4of4 r, 85001-0557 t or, - ,. Issue 7 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1657:0219 Page 1 of I CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, lnc.8985 Town Center Parkway, Bradenton, 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models GC-VM, GCF-VM, GCFR-VM, GC-VMH, GCF-VMI-4, GCWAVMC*, GCWNVMC*, GCWAVMHC* and GCWNVMHC* multiple candela synchronizable strobe lights. The lights are only considered synchronized when used in conjunction with listed Model GI M-RM (CSFM Listing No. 7300-1657:201) sync module, which may employ Model SIGA-CCIS (CSFM Listing No. 7300-1657:121)Auto Sync Output Module. Refer to listees data sheet for additional detailed product description and operational considerations. RATING: Electrical: 16-33 Vdc/Vfwr GC candela: 15cd, 30cd, 75cd, or 95cd H candela: 95cd, 115cd, 150cd, 177cd INSTALLATION: In accordance with listees printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. For indoor use only, mounted on a wall or a ceiling. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as strobe lights for use with separately listed compatible fire alarm control units. Refer to listees Installation Instruction Manual for details. NOTE: Formerly 7125-1591:219 7-29-10 ma This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Strobes, Horns, Bells, Chimes T TM ,_r Life Safety & Communications Field Configurable Ceiling Horn -Strobes Genesis Series EA Pending One or more patents. Overview Genesis ceiling horn-strobes are small, compact, and attractive audible-visible emergency signaling devices. Protruding no more than 1.6" (41 mm) from the ceiling, Genesis horn-strobes blend with any decor. Thanks to patented breakthrough technology, Edwards Gen- esis strobes do not require bulky specular reflectors and lenses. Instead, an exclusive cavity design conditions light to produce a highly controlled distribution pattern. Significant development efforts employing this new technology have given rise to a new benchmark in strobe performance - FullLight technology. FullLight strobe technology produces a smooth light distribution pattern without the spikes and voids characteristic of specular reflectors. This ensures the entire coverage area receives consis- tent illumination from the strobe flash. As a result, Genesis strobes with FullLight technology go well beyond the minimum UL-required "cross" pattern. Depending on the model, Genesis horn-strobes feature 15 to 95, or 95 to 177 candela output (see ordering information), which is selectable with a conveniently-located switch on the front of the device. The candela output setting is clearly visible even after final installation, yet it remains locked in place to prevent unauthorized movement after installation. Genesis horn-strobes feature textured housings in architecturally neu- tral white or eye-catching fire alarm red. An ingenious iconographic symbol indicates the purpose of the device. This universal symbol is code-compliant and is easily recognized by all building occu- pants regardless of what language they speak. Models with "FIRE" markings are also available. Standard Features Field configurable - no need to remove the device! - 15/30/75/95 cd and 95/115/150/177 cd models available - Switch settings remain visible even after the unit is installed - Low/high dB settings Unique low-profile design - 30 per cent slimmer profile than comparable signals - No visible mounting screws - Available with white or red housings Easy to install - Fits all standard 4" square electrical boxes with plenty of room behind the signal for extra wire - no extension ring or trim plate needed - Pre-assembled with captive hardware - no loose pieces - #18 to #12 AWG terminals - ideal for long runs or existing wir- ing Unparalleled performance - Exclusive FullLight strobe technology produces the industry's most even light distribution - Single high-efficiency microprocessor controls both horn and strobe - Low current draw minimizes system overhead - Independent horn control provided over a single pair of wires - Highly regulated in-rush current allows the maximum number of strobes on a circuit - 100 dB peak - multiple frequency tone improves wall penetration Page 1 of 4 'I... 85001-0559 I -, , Issue 9 Application Genesis strobes are UL 1971-listed for use indoors as ceiling- mounted public-mode notification appliances for the hearing impaired. Prevailing codes require strobes to be used where ambi- ent noise conditions exceed 105 dBA (87dBA in Canada), where occupants use hearing protection, and in areas of public accom- modation as defined in the Americans with Disabilities Act (see application notes - USA). Combination horn-strobe signals must be installed in accordance with guidelines established for strobe devices. Strobes Genesis strobes are UL 1971-listed for use indoors as wail-mounted public-mode notification appliances for the hearing impaired. Prevail- ing codes require strobes to be used where ambient noise conditions exceed specified levels, where occupants use hearing protection, and in areas of public accommodation. Consult with your Authority Having Jurisdiction for details. All Genesis strobes exceed UL synchronization requirements (within 10 milliseconds other over a two-hour period) when used with a synchronization source. Synchronization is important in order to avoid epileptic sensitivity. NOTE: The flash intensity of some visible signals may not be adequate to alert or waken occupants in the protected area. Research indicates that the intensity of strobe needed to awaken 90% of sleeping persons is approximately 100 cd. Edwards recommends that strobes in sleeping rooms be rated at at least 110 cd. WARNING: These devices will not operate without electrical power. As fires frequently cause power interruptions, further safeguards such as backup power supplies may be required. Horns Genesis horn output reaches as high as 99 dB (peak) and features a unique multiple frequency tone that results in excel- lent wall penetration and an unmistakable warning of danger. All models may be configured for either coded or non-coded signal circuits. They can also be set for low dB output with a jumper cut that reduces horn output by about 5 dB. The suggested sound pressure level for each signaling zone used with alert or alarm signals is at least 15 dB above the average ambient sound level, or 5 dB above the maximum sound level having a duration of at least 60 seconds, whichever is greater, measured 5 feet (1.5 m) above the floor. The average ambient sound level is, A-weighted sound pressure measured over a 24-hour period. Installation and Mounting All models are intended for indoor wall or ceiling applications only. Horn-strobes mount to any flush North-American 4" square electrical box. Genesis ceiling horn-strobes simply unlatch and twist to open. This gains access to mounting screws and the selectable candela switch. The shallow depth of Genesis devices leaves ample room behind the signal for extra wiring. Once installed with the cover in place, no mounting screws are visible. Edwards recommends that these fire alarm horn-strobes always be installed in accordance with the latest recognized edition of national and local fire alarm codes. Field Configuration Depending on the model, Genesis horn-strobes may be set for 15 to 95, or 95 to 177 candela output (see ordering information). The output setting is changed by simply opening the device and sliding the switch to the desired setting. The horn-strobe does not have to be removed to change the output setting. The setting remains visible through a small window on the front of the device after the cover is closed. The horn-strobe comes factory set for high dB output. Low dB output may be selected by cutting a jumper on the circuit board. This reduces the output by about 5 dB. Wiring Field wiring terminals accommodate #18 to #12 AWG (0.75 mm2 to 2.5 mmg wiring. Horn/strobes are interconnected with a single pair of wires as shown below. Doubling the distance from the signal to the ear will theoretically result in a 6 dB reduction of the received sound pressure level. The actual effect depends on the acoustic properties of materials in the space. A 3 dBA difference represents a barely noticeable change in volume. Dimensions 6.8"dia. 11 (173 mm) -.... I (25 mm) O.60"(15 mm) Polarity shown In alarm condition Note: Strobes must have continuous voltage. To next appliance, end-of.Iine or return to control equipment Page 2of4 -: - 85001-0559 A - 1 or 1L. - F Issue Light output - (effective cd) Percent of UL rating versus angle P.,C.ntULR.T Current Draw GC-HDVM Temporal Horn-strobe: High dB Setting UL 15 cd 30 cd 75 cd 95 cd Rating RMS RMS RMS RMS 16 Vdc 147 190 316 372 16Vfwr 189 253 417 451 GC-HDVM Temporal Horn-strobe: High dB Setting Typical 15 cd 30 cd 75 cd 95 cd Current RMS Mean RMS Mean RMS Mean RMS Mean 16 Vdc 111 95 152 143 281 276 333 328 20 Vdc 91 80 124 117 219 214 257 251 24 Vdc 80 71 108 101 185 180 212 207 33 Vdc 69 62 89 84 144 140 160 156 16Vfwr 153 81 218 123 388 240 420 268 20Vfwr 141 70 190 100 325 188 378 219 24Vfwr 135 64 176 90 280 154 310 180 33Vfwr 139 61 167 80 241 122 254 133 GC-HDVM Temporal Horn-strobe: Low dB Setting Typical 15 cd 30 cd 75 cd 95 cd Current RMS Mean RMS Mean RMS Mean RMS Mean 16 Vdc 108 91 149 139 275 269 327 322 20 Vdc 87 75 120 113 214 209 250 245 24 Vdc 76 66 103 97 180 175 205 201 33 Vdc 64 57 85 80 138 135 153 150 16Vfwr 141 76 204 118 384 239 418 265 20Vfwr 127 65 176 95 312 181 371 214 24Vfwr 118 60 162 82 262 149 301 171 33Vfwr 127 56 155 73 229 118 249 129 GC-HDVMH High cd Temporal Horn-strobe: High dB Setting 95 cd 115 cd 150 cd 177 cd RMS RMS RMS RMS 341 399 506 570 487 578 670 711 GC-HDVMH High cd Temporal Horn-strobe: High dB Setting 95 cd 115 cd 150 cd 177 cd RMS Mean RMS Mean RMS Mean RMS Mean 324 322 377 374 477 474 554 551 258 256 299 296 369 366 417 414 220 217 252 249 304 301 341 338 172 169 188 185 223 220 244 241 463 265 535 312 665 400 718 442 392 211 439 240 517 287 587 334 346 179 382 212 458 246 498 271 296 142 323 152 358 178 387 194 GC-HDVMH High cd Temporal Horn-strobe: Low dB Setting 95 cd 115 cd 150 cd 177 cd RMS Mean RMS Mean RMS Mean RMS Mean 317 315 378 376 480 477 544 542 252 250 292 290 364 362 414 411 212 211 245 243 297 295 334 332 159 157 181 179 215 213 234 232 461 265 521 305 656 396 705 432 381 208 437 242 508 285 576 326 335 172 370 195 440 235 485 264 285 134 308 149 349 169 373 186 4 Notes and Comments Current values are shown in mA. UL Nameplate Rating can vary from Typical Current due to measurement methods and instruments used. Edwards recommends using the Typical Current for system design including NAC and Power Supply loading and voltage drop calculations. Use the Vdc RMS current ratings for filtered power supply and battery AH calculations. Use the Vfwr RMS current ratings for unfiltered power supply calculations. Fuses, circuit breakers and other overcurrent protection devices are typically rated for current in RMS values. Most of these devices operate based upon the heating affect of the current flowing through the device. The RMS current (not the mean current) determines the heating affect and therefore, the trip and hold threshold for those devices. Our industry has used mean currents over the years. However, UL will direct the industry to use the 2004 RMS values in the future. dBA output High dB Setting UL464 Average Peak Temporal Steady Temporal! Steady Temporal! Steady 16 Vdc 79.8 83.2 90.6 93.6 24 Vdc 83.3 85.4 93.6 96.6 33 Vdc 1 85 1 87.8 1 95.7 1 98.7 Low dB Setting UL464 Average Peak Temporal Steady Temporal! Steady Temporal/ Steady 16 Vdc 75 79.3 86.3 88.7 24 Vdc 78 83 88.8 92.4 33 Vdc 80.9 85.9 91.8 1 95.1 Notes 1. All values shown are dBA measured at 10 feet (3.01m); 2. UL464 values measured in reverberation room; 3. Average and Peak values are measured in anechoic cham- ber. Page 3of4 • 85001-0559 r.oJ Issue Specifications cEDvVoR D S Housing Textured IN stabilized, color impregnated engineered plastic. Exceeds 94V- 0 UL flammability rating. Red and white models available. A UTC Fire & Security Company Lens Optical grade polycarbonate (clear) Detection & alarm since 1872 Mounting North-American 4" square box, 2 1/8" (54 mm) deep (indoor wall or ceiling applications only). U.S. Wire connections Screw terminals: single input for both horn and strobe. #18 to #12 1888-378-2329 AWG (0.75 mm2 to 2.5 mm2) wire size F 866-503-3996 Operating environment Indoor: 32-120°F (0-49°C) ambient temperature. 93% relative humidity Canada Meets or exceeds ULC-5541 year 2004 UL requirements for Chubb Edwards Agency listings/approvals standards UL1 638 and UL1 971 and complies with UL1 480. All horn- T 519376 2430 strobes comply with ADA Code of Federal Regulation Chapter 28 Part F 519 376 7258 36 Final Rule. CSFM, MEA. FM pending. GC-HDVM series temporal-tone horn-strobes: non-coded, filtered Southeast Asia 1: +65 6391 9300 Operating voltage 16-33 Vdc or unfiltered 16-33 Vdc FWR (or coded (audible NAC only) F: +65 6391 9306 _______________________________________________________________________________________ when used with optional G1 M Genesis Signal Master) Strobe output rating UL 1971 UL 1638, ULC S526: selectable 15/30/75/95 cd (GC- India HDVM) and 95/115/150/177 cd (GC-HDVMH) 1: +9180 4344 2000 GC-HDVM senes temporal-tone horn-strobes: one flash per second F: +91 80 4344 2050 synchronized with optional Gi M Genesis Signal Master indefinitely Australia Strobe flash rate within 10 milliseconds (or self-synchronized within 200 milliseconds T +61 39239 1200 over thirty minutes on a common circuit without Gi M Genesis Signal F +61 3 9239 1299 Master) Temporal setting (private mode only): synchronized to temporal output of horns on same circuit Europe Synchronization Sources G1 M-RM, SIGA-CC1 S, SIGA-MCC1 5, BPS6A, BPS1 OA 1+3227251120 F+32272186 13 GC-HDVM series temporal-tone horn-strobes: temporal rate synchronized with optional G1 M Genesis Signal Master indefinitely Latin America Horn pulse rate within 10 milliseconds (or self-synchronized within 200 milliseconds T 305 593 4301 over thirty minutes on a common circuit without G1 M Genesis Signal F 305 593 4300 Master) utcfireandsecurity.com Temporal audible pattern 1 sec ON, sec OFF, ½ sec ON, ½ sec OFF, sec ON, 1½ sec OFF, then repeat cycle ©2O1OUTC Fire &Security. All rights reserved. Ordering Information Catalog Housing Ship Number Color Marking Description Wt. lbs (kg) GC-HDVM White None GCF-HDVM White "FIRE" Genesis Ceiling/Wall Horn-Strobe GCFR-HDVM Red "FIRE" With selectable 15, 30, 75, or 95 cd output 0.82 GC-HDVMH White None Genesis Ceiling/Wall Horn-Strobe (1.8) GCF-HDVMH White "FIRE" with selectable 95, 115, 150, or 177 cd output Accessories 0.2 G1M-RM Genesis Signal Master - Remote Mount (1-gang) SIGA-CC1S Intelligent Synchronization Output Module (2-gang) 0.5 (0.23) SIGA-MCC1S Intelligent Synchronization Output Module (Plug-in UIO) 0.18 (0.08) Ion White Reid Configurable Ceiling Horn-Strobes may be ordered with or without optional FIRE' marking. Red Horn-Strobes come with 'FIRE" marking. Page 4 of 4 85001 -0559 I, it. I •,,tilipc Issue 9 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1657:0202 Page 1 of I CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models "EST' G1-HV15, -HV30, -HV60, -HV-75, GI-HOVI5, -HOV30, -HOV60, -H0V75, -HOV110, GIF-HOVIS, -HOV30, -HOV60, -H0V75, -HOVIIO, GIRF-HOVI5, -HOV30, -HOV60, -HOW5, -HOV110, GI-HDVM, GIR-HDVM, GIF-HDVM, G1RF-HDVM, GC-HDVM, GC-HDVMH, GCF-HDVM, GCFR-HDVM, GCF-HDVMH, GI-HDV1575, Gi R-HDV1575, GI F-HDV1575, and Gi RF-H0V1575 horn/strobes with or without suffixes -R and -F. Models with HO as part of the model number are a high audible output version of the standard output model. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 24-30 Vdc 16-33 Vdc/Vfwr - Models GI-HDVM, GIR-HDVM, G1F-HDVM, GIRF-HDVM, GC-HDVM, GC-HDVMH, GCF-HDVM, GCFR-HDVM, GCF-HDVMH, GI-H0V1575, GI R-HDV1575, GI F-HDV1575, GI RF-HDV1575 Candela: 15cd, 30cd, 60cd, 75cd, 110cd 15-95 multi-cd - Models GC-HDVM, GCF-HDVM, GCFR-HVDM 95-177 multi-cd-Models GC-HDVMH, GCF-HDVMH 15175cd -Models GI-HDV1575, GI R-HDV1575, GI F-H0V1575, GI RF-HDV1575 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as horns and horn/strobe lights for use with separately listed compatible fire alarm control units. Suitable for use with Audible Signal Appliances (CSFM Listing No. 7135-1657:230). For indoor use and wall mount only. Models GC-HDVM, *GC..HDVMH GCFR-HDVM, GCF-HDVM and *GCF-HDVMH for ceiling or wall mount. Refer to listee's Installation Instruction Manual for details. These units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. NOTE: Formerly 7125-1591:202 *REV 08-20-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAWD CASTILLO, Program Coordinator Fire Engineering Division a 4 S FPC20I9-0134 7030 AVENIDA ENCINAS - #100 SPECTRUM - NEW ARE ALARM 2144301400 6/17/2019 FPC20I9-0134