Loading...
HomeMy WebLinkAbout1900 ASTON AVE; ; AS1600829/21/23, 2:19 PM AS160082 Permit Data City of Carlsbad Sprinkler Permit Job Address: 1900 ASTON AV Permit Type: SPRINK Parcel No: 2121202400 Lot #: 0 Reference No.: Permit No: AS160082 Status: ISSUED Applied 4/6/2016 Approved: 4/29/2016 Issued: 4/29/2016 PC #: Inspector: Project Title: ZIMMER BIOMET RELOCATION OF EXISTING FIRE SPRINKLER DROPS FOR NEW WALLS/ROOM CONFIGURATIONS. Applicant: A & D FIRE SPRINKLERS 7130 CONVOY CT SAN DIEGO, CA 858-277-3473 Owner: P D G CARLSBAD 59 LTD 1825 GILLESPIE WAY #102 EL CAJON CA Fees ($) Add'l Fees ($) Total ($) Balance ($) 573 0 573 0 about:blank 1/1 FIRE SPRINKLERS INC. A&D FIRE SPRINKLERS 7130 CONVOY COURT SAN DIEGO CA 92111 (858) 277-3473 Job Name : ZIMMER BIOMET (CORRECTION 2) Building Location System Contract Data File : ZIMMER BIOMET (CORRECTION 2) Area 3.WXF ASI 60082 1900 ASTON AV - 1vtctc Arem CcIC.. City Water Suppjy: Cl - Static Pressure : C2 - Residual Pressure: 100 70.6 C2 - Residual Flow : 1629.6 Demand: Dl - Elevation : 11.910 D2 - System Flow :484.09 D2 - System Pressure : 71.939 Hose ( Demand) D3 - System Demand :484-09 Safety Margin : 24.949 Water SuppI rveC A&D FIRE SPRINKLERS Page 1 ZIMMER BIOMET (CORRECTION 2) Date 150 140 130 P 120 R 110 Cl E 100 S90 S80 C2 U 70 R 60 E 50 40 30 20 10 200 400 600 800 1000 1200 1400 1600 1800 FLOW (NA 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used nmary A&D FIRE SPRINKLERS Page 2 ZIMMER BIOMET (CORRECTION 2) Date Fitting Legend Abbrev. Name 1/2 % 1 114 1% 2 2% 3 3% 4 5 6 8 10 12 14 16 18 20 24 E NFPA 13 90' Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 T NFPA 13 90' Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Units Summary Diameter Units Length Units Flow Units Pressure Units Inches Feet US Gallons per Minute Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with * The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure'/ Flow Summary - STANDARD A&D FIRE SPRINKLERS Page 3 ZIMMER BIOMET (CORRECTION 2) Date Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. DP02 12.0 11.2 12.8 na 40.07 0.1 400 12.8 S22 27.5 13.27 na EQ02 27.5 16.1 na DP05 12.0 11.2 12.8 na 40.07 0.1 400 12.8 E005 27.5 17.74 na DP03 12.0 11.2 12.8 na 40.07 0.1 400 12.8 E003 27.5 17.4 na DP07 12.0 11.2 12.8 na 40.07 0.1 400 12.8 S17 27.75 13.27 na EQ07 27.5 19.19 na DP06 12.0 11.2 12.8 na 40.07 0.1 400 12.8 S18 27.75 13.27 na EQ06 27.5 19.25 na DPOI 12.0 11.2 33.7 na 65.02 0.1 324 33.7 S20 27.5 4458 na EQ01 27.5 52.54 na DPO4 12.0 11.2 33.7 na 65.02 0.1 324 33.7 S19 27.5 44.58 na EQ04 27.5 55.05 na 20 27.5 K = K @ EQ06 55.09 na 67.79 M22B 27.5 58.68 na M22 25.67 59.99 na M23 25.67 60.03 na M24 25.67 60.09 na 2 25.67 60.51 na BOR 0.0 71.94 na 19 27.5 K = K @ EQ05 55.0 na 70.56 9.2 27.5 K = K © EQ04 55.05 na 65.02 27.5 57.95 na 25.67 59.31 na 5 25.67 59.32 na M6 25.67 59.34 na M7 25.67 59.35 na M8 25.67 59.35 na 5 25.67 59.35 na 6 10.25 66.33 na 7 10.25 66.35 na 8 10.25 66.36 na 9 10.25 66.58 na 10 10.25 66.58 na 11 25.67 59.92 na 12 25.67 59.94 na M18 25.67 59.94 na M19 25.67 59.95 na M20 25.67 59.96 na M21 25.67 59.97 na WA 25.67 59.31 na M2A 25.67 59.32 na M1A 25.67 59.32 na Ml 27.5 58.62 na M25B 27.5 59.66 na M25 25.67 60.51 na M3 27.5 57.88 na 33 27.5 K = K © EQOI 54.61 na 66.28 34 27.5 K = K © EQ02 54.49 na 73.71 35 27.5 K = K © EQ03 54.53 na 70.94 M23B 27.5 58.71 na M2 27.5 58.57 na M24B 27.5 59.24 na M5A 27.5 58.48 na 18 27.5 K = K © EQ07 58.2 na 69.79 M21B 27.5 59.07 na M6A 27.5 58.58 na 27.5 58.79 na 27.5 58.82 na Flow Summary - Standard A&D FIRE SPRINKLERS Page 4 ZIMMER BIOMET (CORRECTION 2) Date Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. 1 27.5 58.86 na M20B 27.5 59.13 na WA 27.5 58.59 na 13 27.5 58.78 na 14 27.5 58.8 na 15 27.5 58.83 na 16 27.5 58.84 na 17 27.5 58.86 na MI9B 27.5 59.12 na M8A 27.5 58.6 na M18B 27.5 59.11 na M9 25.67 59.35 na M10 25.67 59.36 na Mil 25.67 59.36 na M12 25.67 59.36 na M12A 27.5 58.6 na M14B 27.5 59.11 na M14 25.67 59.94 na M15 25.67 59.94 na M16 25.67 59.94 na M17 25.67 59.94 na M9A 27.5 58.6 na MI7B 27.5 59.11 na M10A 27.5 58.6 na M16B 27.5 59.11 na M1 1A 27.5 58.6 na M15B 27.5 59.11 na 21 10.25 66.58 na 10.25 66.58 na 10.25 66.56 na 10.25 66.54 na 27 10.25 66.53 na 23 10.25 66.54 na 24 10.25 66.56 na 25 10.25 66.56 na Final Calculations - Hazen-Williams - 2007 A&D FIRE SPRINKLERS Page 5 ZIMMER BIOMET (CORRECTION 2) Date .jd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn *EQUIVALENT K'S DP02 40.07 1.083 E 2.336 15.500 12.800 K Factor= 11.20 to 120.0 0.0 2.336 -6.713 S22 40.07 0.4029 0.0 17.836 7.187 Vel = 13.96 S22 0.0 1.083 T 5.84 1.180 13.274 to 120.0 0.0 5.840 0.0 EQ02 40.07 0.4028 0.0 7.020 2.828 Vel = 13.96 0.0 40.07 16.102 K Factor = 9.99 DPOS 40.07 1.083 2E 4.672 18.400 12.800 K Factor= 11.20 to 120.0 T 5.84 10.512 -6.713 EQ05 40.07 0.4029 0.0 28.912 11.650 Vel= 13.96 0.0 40.07 17.737 K Factor = 9.51 DP03 40.07 1.083 2E 4.672 17.560 12.800 K Factor= 11.20 to 120.0 T 5.84 10.512 -6.713 EQ03 40.07 0.4029 0.0 28.072 11.311 Vel = 13.96 0.0 40.07 17.398 K Factor= 9.61 DP07 40.07 1.083 E 2.336 15.750 12.800 K Factor = 11.20 to 120.0 0.0 2.336 -6.821 S17 40.07 0.4029 0.0 18.086 7.287 Vel = 13.96 S17 0.0 1.083 E 2.336 6.250 13.266 to 120.0 T 5.84 8.176 0.108 EQ07 40.07 0.4030 0.0 14.426 5.813 Vel = 13.96 0.0 40.07 19.187 KFactor= 9.15 DP06 40.07 1.083 E 2.336 15.750 12.800 K Factor = 11.20 to 120.0 0.0 2.336 -6.821 S18 40.07 0.4029 0.0 18.086 7.287 Vel = 13.96 S18 0.0 1.083 E 2.336 6.400 13.266 to 120.0 T 5.84 8.176 0.108 EQ06 40.07 0.4030 0.0 14.576 5.874 Vel = 13.96 0.0 40.07 19.248 K Factor= 9.13 DPOI 65.02 1.083 E 2.336 15.500 33.700 K Factor = 11.20 to 120.0 0.0 2.336 -6.713 S20 65.02 0.9865 0.0 17.836 17.596 Vel = 22.65 S20 0.0 1.083 T 5.84 2.230 44.583 to 120.0 0.0 5.840 0.0 EQOI 65.02 0.9866 0.0 8.070 7.962 Vel = 22.65 0.0 65.02 52.545 K Factor = 8.97 DP04 65.02 1.083 E 2.336 15.500 33.700 K Factor = 11.20 to 120.0 0.0 2.336 -6.713 S19 65.02 0.9865 0.0 17.836 17.596 Vel = 22.65 Final Calculations - Hazen-Williams A&D FIRE SPRINKLERS Page 6 ZIMMER BIOMET (CORRECTION 2) Date .jd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 519 0.0 1.083 T 5.84 4.770 44.583 to 120.0 0.0 5.840 0.0 EQ04 65.02 0.9866 0.0 10.610 10.468 Vel = 22.65 0.0 65.02 55.051 K Factor = 8.76 *REMOTE HEAD TO SUPPLY 20 99.20 2.635 T 16.474 110.000 55.089 K Factor @ node EQ06 to 120.0 0.0 16.474 0.0 M22B 99.2 0.0284 0.0 126.474 3.589 Vel = 5.84 M22B 0.0 2.635 T 16.474 1.830 58.678 to 120.0 0.0 16.474 0.793 M22 99.2 0.0284 0.0 18.304 0.519 Vel = 5.84 M22 218.38 6.357 0.0 11.000 59.990 to 120.0 0.0 0.0 0.0 M23 317.58 0.0034 0.0 11.000 0.037 Vel = 3.21 M23 99.76 6.357 0.0 10.500 60.027 to 120.0 0.0 0.0 0.0 024 417.34 0.0056 0.0 10.500 0.059 Vel = 4.22 I24 27.54 6.357 E 17.603 49.500 60.086 to 120.0 0.0 17.603 0.0 2 444.88 0.0062 0.0 67.103 0.419 Vel = 4.50 2 39.21 6.357 T 37.72 5.500 60.505 to 120.0 0.0 37.720 11.118 BOR 484.09 0.0073 0.0 43.220 0.316 Vel = 4.89 0.0 484.09 71.939 KFactor= 57.07 *NEW PATH 20 -31.41 2.635 0.0 25.000 55.089 to 120.0 0.0 0.0 0.0 19 -31.41 -0.0034 0.0 25.000 -0.084 Vel = 1.85 19 70.56 2.635 0.0 9.050 55.005 K Factor © node EQ05 to 120.0 0.0 0.0 0.0 9.2 39.15 0.0051 0.0 9.050 0.046 Vel = 2.30 9.2 to 65.02 2.635 120.0 T 16.474 0.0 76.950 16.474 55.051 0.0 K Factor @ node EQ04 M4A 104.17 0.0311 0.0 93.424 2.902 Vel = 6.13 M4A 0.0 2.635 T 16.474 1.830 57.953 to 120.0 0.0 16.474 0.793 M4 104.17 0.0310 0.0 18.304 0.568 Vel = 6.13 M4 44.42 6.357 0.0 11.000 59.314 120.0 0.0 0.0 0.0 148.59 0.0008 0.0 11.000 0.009 Vel = 1.50 M5 27.13 6.357 0.0 11.000 59.323 to 120.0 0.0 0.0 0.0 M6 175.72 0.0012 0.0 11.000 0.013 VeI= 1.78 Final Calculations - Hazen-Williams A&D FIRE SPRINKLERS Page 7 ZIMMER BIOMET (CORRECTION 2) Date .,d. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn M6 -24.58 6.357 0.0 11.500 59.336 to 120.0 0.0 0.0 0.0 M7 151.14 0.0008 0.0 11.500 0.009 Vel= 1.53 M7 -24.16 6.357 0.0 8.500 59.345 to 120.0 0.0 0.0 0.0 M8 126.98 0.0007 0.0 8.500 0.006 Vel = 1.28 MB -23.93 6.357 0.0 0.500 59.351 to 120.0 0.0 0.0 0.0 5 103.05 0.0 0.0 0.500 0.0 Vel = 1.04 5 -94.83 1.442 3E 11.148 37.520 59.351 to 120.0 T 7.432 18.580 6.678 6 8.22 0.0053 0.0 56.100 0.300 Vel = 1.61 6 -3.01 1.442 0.0 10.200 66.329 to 120.0 0.0 0.0 0.0 7 5.21 0.0023 0.0 10.200 0.023 Vel = 1.02 7 -2.67 1.442 0.0 9.700 66.352 to 120.0 0.0 0.0 0.0 3 2.54 0.0006 0.0 9.700 0.006 Vel = 0.50 3 0.0 1.442 T 7.432 350.980 66.358 to 120.0 2E 7.432 14.864 0.0 9 2.54 0.0006 0.0 365.844 0.222 Vel = 0.50 9 0.0 2.157 0.0 6.000 66.580 to 120.0 0.0 0.0 0.0 10 2.54 0.0002 0.0 6.000 0.001 Vel = 0.22 10 5.68 2.157 T 12.307 3.000 66.581 to 120.0 E 6.153 18.460 -6.678 11 8.22 0.0007 0.0 21.460 0.015 VeI= 0.72 11 0.0 2.157 E 6.153 16.420 59.918 to 120.0 T 12.307 18.460 0.0 12 8.22 0.0007 0.0 34.880 0.026 Vel = 0.72 12 94.83 6.357 0.0 0.500 59.944 to 120.0 0.0 0.0 0.0 M18 103.05 0.0020 0.0 0.500 0.001 Vel = 1.04 M18 23.93 6.357 0.0 8.500 59.945 to 120.0 0.0 0.0 0.0 M19 126.98 0.0006 0.0 8.500 0.005 Vel = 1.28 M19 24.16 6.357 0.0 11.500 59.950 to 120.0 0.0 0.0 0.0 M20 151.14 0.0009 0.0 11.500 0.010 Vel= 1.53 M20 24.58 6.357 0.0 11.000 59.960 to 120.0 0.0 0.0 0.0 M21 175.72 0.0011 0.0 11.000 0.012 Vel = 1.78 M21 42.66 6.357 0.0 11.000 59.972 to 120.0 0.0 0.0 0.0 M22 218.38 0.0016 0.0 11.000 0.018 Vel = 2.21 Final Calculations - Hazen-Williams A&D FIRE SPRINKLERS Page 8 ZIMMER BIOMET (CORRECTION 2) Date Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 218.38 59.990 K Factor= 28.20 *NEW PATH M4 44.42 6.357 0.0 11.000 59.314 to 120.0 0.0 0.0 0.0 M3A 44.42 -0.0001 0.0 11.000 -0.001 Vel = 0.45 M3A 111.17 6.357 0.0 10.500 59.313 to 120.0 0.0 0.0 0.0 M2A 66.75 0.0002 0.0 10.500 0.002 Vel = 0.67 M2A -27.54 6.357 0.0 10.000 59.315 to 120.0 0.0 0.0 0.0 MIA 39.21 0.0001 0.0 10.000 0.001 Vel = 0.40 MIA 0.0 2.635 T 16.474 1.830 59.316 to 120.0 0.0 16.474 -0.793 Ml 39.21 0.0051 0.0 18.304 0.094 Vel = 2.31 Ml 0.0 2.635 1 16.474 180.290 58.617 to 120.0 E 8.237 24.711 0.0 V125B 39.21 0.0051 0.0 205.001 1.044 Vel = 2.31 M2513 0.0 2.635 E 8.237 1.830 59.661 to 120.0 0.0 8.237 0.793 M25 39.21 0.0051 0.0 10.067 0.051 Vel = 2.31 M25 0.0 6.357 0.0 1.210 60.505 to 120.0 0.0 0.0 0.0 2 39.21 0.0 0.0 1.210 0.0 Vel = 0.40 0.0 39.21 60.505 K Factor = 5.04 *NEW PATH M3A -111.17 2.635 T 16.474 1.830 59.313 to 120.0 0.0 16.474 -0.793 M3 -111.17 -0.0350 0.0 18.304 -0.641 Vel = 6.54 M3 0.0 2.635 T 16.474 76.950 57.879 to 120.0 0.0 16.474 0.0 33 -111.17 -0.0350 0.0 93.424 -3.273 Vel = 6.54 33 66.28 2.635 0.0 18.060 54.606 K Factor @ node EQOI to 120.0 0.0 0.0 0.0 34 -44.89 -0.0065 0.0 18.060 -0.118 Vel = 2.64 34 73.71 2.635 0.0 12.990 54.488 K Factor @ node EQ02 to 120.0 0.0 0.0 0.0 35 28.82 0.0028 0.0 12.990 0.037 Vel = 1.70 35 70.93 2.635 2T 32.948 113.000 54.525 K Factor © node EQ03 4,1 120.0 0.0 32.948 0.0 423B 99.75 0.0287 0.0 145.948 4.185 Vel = 5.87 M23B 0.0 2.635 T 16.474 1.830 58.710 to 120.0 0.0 16.474 0.793 M23 99.75 0.0286 0.0 18.304 0.524 Vel = 5.87 Final Calculations - Hazen-Williams A&D FIRE SPRINKLERS Page 9 ZIMMER BIOMET (CORRECTION 2) Date .jd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 99.75 60.027 K Factor= 12.87 *NEW PATH M2A 27.54 2.635 T 16.474 1.830 59.315 to 120.0 0.0 16.474 -0.793 M2 27.54 0.0027 0.0 18.304 0.049 Vel = 1.62 M2 0.0 2.635 2T 32.948 221.000 58.571 to 120.0 0.0 32.948 0.0 M24B 27.54 0.0027 0.0 253.948 0.673 Vel = 1.62 M24B 0.0 2.635 T 16.474 1.830 59.244 to 120.0 0.0 16.474 0.793 M24 27.54 0.0027 0.0 18.304 0.049 Vel = 1.62 0.0 27.54 60.086 K Factor = 3.55 *NEW PATH M5 -27.13 2.635 T 16.474 1.830 59.323 120.0 0.0 16.474 -0.793 V15A -27.13 -0.0025 0.0 18.304 -0.046 Vel = 1.60 M5A 0.0 2.635 T 16.474 92.000 58.484 to 120.0 0.0 16.474 0.0 18 -27.13 -0.0026 0.0 108.474 -0.280 Vel = 1.60 18 69.79 2.635 T 16.474 129.000 58.204 K Factor @ node EQ07 to 120.0 0.0 16.474 0.0 M21 42.66 0.0060 0.0 145.474 0.866 Vel = 2.51 M21 0.0 2.635 T 16.474 1.830 59.070 to 120.0 0.0 16.474 0.793 M21 42.66 0.0060 0.0 18.304 0.109 Vel = 2.51 0.0 42.66 59.972 K Factor= 5.51 *NEW PATH M6 24.58 2.635 T 16.474 1.830 59.336 to 120.0 0.0 16.474 -0.793 M6A 24.58 0.0021 0.0 18.304 0.039 Vel = 1.45 M6A 0.0 2.635 T 16.474 78.200 58.582 to 120.0 0.0 16.474 0.0 4 24.58 0.0022 0.0 94.674 0.204 Vel = 1.45 4 0.0 2.635 0.0 13.800 58.786 to 120.0 0.0 0.0 0.0 3 24.58 0.0021 0.0 13.800 0.029 Vel = 1.45 3 0.0 2.635 0.0 19.000 58.815 120.0 0.0 0.0 0.0 1 24.58 0.0022 0.0 19.000 0.041 Vel = 1.45 1 0.0 2.635 T 16.474 110.000 58.856 to 120.0 0.0 16.474 0.0 M20B 24.58 0.0022 0.0 126.474 0.272 Vel = 1.45 Final Calculations - Hazen-Williams Page 10 Date .-lyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt PfIFt Eqv. Ln. Total Pf Pn M20B 0.0 2.635 1 16.474 1.830 59.128 to 120.0 0.0 16.474 0.793 M20 24.58 0.0021 0.0 18.304 0.039 Vel = 1.45 0.0 24.58 59.960 KFactor= 3.17 *NEW PATH M7 24.16 2.635 T 16.474 1.830 59.345 to 120.0 0.0 16.474 -0.793 M7A 24.16 0.0021 0.0 18.304 0.039 Vel = 1.42 M7A 0.0 2.635 T 16.474 74.200 58.591 to 120.0 0.0 16.474 0.0 13 24.16 0.0021 0.0 90.674 0.189 Vel= 1.42 13 0.0 2.635 0.0 8.000 58.780 to 120.0 0.0 0.0 0.0 14 24.16 0.0020 0.0 8.000 0.016 Vel = 1.42 14 0.0 2.635 0.0 14.000 58.796 to 120.0 0.0 0.0 0.0 15 24.16 0.0021 0.0 14.000 0.029 Vel = 1.42 15 0.0 2.635 0.0 6.290 58.825 to 120.0 0.0 0.0 0.0 16 24.16 0.0021 0.0 6.290 0.013 Vel = 1.42 16 0.0 2.635 0.0 9.460 58.838 to 120.0 0.0 0.0 0.0 17 24.16 0.0021 0.0 9.460 0.020 Vel = 1.42 17 0.0 2.635 T 16.474 109.050 58.858 to 120.0 0.0 16.474 0.0 M19B 24.16 0.0021 0.0 125.524 0.261 Vel = 1.42 M19B 0.0 2.635 T 16.474 1.830 59.119 to 120.0 0.0 16.474 0.793 M19 24.16 0.0021 0.0 18.304 0.038 Vel= 1.42 0.0 24.16 59.950 K Factor = 3.12 *NEW PATH M8 23.93 2.635 1 16.474 1.830 59.351 to 120.0 0.0 16.474 -0.793 M8A 23.93 0.0020 0.0 18.304 0.037 Vel = 1.41 M8A 0.0 2.635 2T 32.948 221.000 58.595 to 120.0 0.0 32.948 0.0 M18B 23.93 0.0020 0.0 253.948 0.520 Vel = 1.41 M18B 0.0 2.635 T 16.474 1.830 59.115 120.0 0.0 16.474 0.793 018 23.93 0.0020 0.0 18.304 0.037 Vel = 1.41 0.0 23.93 59.945 K Factor = 3.09 *NEW PATH Final Calculations - Hazen-Williams A&D FIRE SPRINKLERS Page 11 ZIMMER BIOMET (CORRECTION 2) Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 5 94.82 6.357 0.0 8.000 59.351 to 120.0 0.0 0.0 0.0 M9 94.82 0.0004 0.0 8.000 0.003 Vel = 0.96 M9 -23.80 6.357 0.0 10.000 59.354 to 120.0 0.0 0.0 0.0 MIO 71.02 0.0002 0.0 10.000 0.002 Vel = 0.72 MIO -23.70 6.357 0.0 10.000 59.356 to 120.0 0.0 0.0 0.0 Mil 47.32 0.0001 0.0 10.000 0.001 Vet = 0.48 Mu -23.67 6.357 0.0 10.000 59.357 to 120.0 0.0 0.0 0.0 M12 23.65 0.0 0.0 10.000 0.0 Vet = 0.24 M12 0.0 2.635 T 16.474 1.830 59.357 to 120.0 0.0 16.474 -0.793 M12A 23.65 0.0020 0.0 18.304 0.037 Vel = 1.39 M12A 0.0 2.635 2T 32.948 221.000 58.601 to 120.0 0.0 32.948 0.0 M14B 23.65 0.0020 0.0 253.948 0.508 Vel = 1.39 M14B 0.0 2.635 T 16.474 1.830 59.109 to 120.0 0.0 16.474 0.793 M14 23.65 0.0020 0.0 18.304 0.036 Vet = 1.39 M14 0.0 6.357 0.0 10.000 59.938 to 120.0 0.0 0.0 0.0 M15 23.65 0.0 0.0 10.000 0.0 Vel = 0.24 MIS 23.67 6.357 0.0 10.000 59.938 to 120.0 0.0 0.0 0.0 M16 47.32 0.0002 0.0 10.000 0.002 Vel = 0.48 M16 23.70 6.357 0.0 10.000 59.940 to 120.0 0.0 0.0 0.0 M17 71.02 0.0002 0.0 10.000 0.002 Vet = 0.72 M17 23.80 6.357 0.0 8.000 59.942 to 120.0 0.0 0.0 0.0 12 94.82 0.0002 0.0 8.000 0.002 Vel = 0.96 0.0 94.82 59.944 KFactor= 12.25 *NEW PATH M9 23.80 2.635 T 16.474 1.830 59.354 to 120.0 0.0 16.474 -0.793 M9A 23.8 0.0020 0.0 18.304 0.037 Vel = 1.40 M9A 0.0 2.635 2T 32.948 221.000 58.598 to 120.0 0.0 32.948 0.0 A17B 23.8 0.0020 0.0 253.948 0.514 Vel = 1.40 M1713 0.0 2.635 T 16.474 1.830 59.112 to 120.0 0.0 16.474 0.793 M17 23.8 0.0020 0.0 18.304 0.037 Vel = 1.40 Final Calculations - Hazen-Williams A&D FIRE SPRINKLERS Page 12 ZIMMER BIOMET (CORRECTION 2) Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt P1/Ft Eqv. Ln. Total Pf Pn 0.0 23.80 59.942 K Factor = 3.07 *NEW PATH MIO 23.71 2.635 T 16.474 1.830 59.356 to 120.0 0.0 16.474 -0.793 MIOA 23.71 0.0020 0.0 18.304 0.037 Vel = 1.39 MIOA 0.0 2.635 2T 32.948 221.000 58.600 to 120.0 0.0 32.948 0.0 M16B 23.71 0.0020 0.0 253.948 0.510 Vel = 1.39 M16B 0.0 2.635 T 16.474 1.830 59.110 to 120.0 0.0 16.474 0.793 M16 23.71 0.0020 0.0 18.304 0.037 Vel = 1.39 0.0 23.71 59.940 K Factor= 3.06 *NEW PATH Mil 23.66 2.635 T 16.474 1.830 59.357 to 120.0 0.0 16.474 -0.793 MIIA 23.66 0.0020 0.0 18.304 0.037 Vel = 1.39 M11A 0.0 2.635 2T 32.948 221.000 58.601 to 120.0 0.0 32.948 0.0 MISB 23.66 0.0020 0.0 253.948 0.508 Vel = 1.39 M15B 0.0 2.635 1 16.474 1.830 59.109 to 120.0 0.0 16.474 0.793 M15 23.66 0.0020 0.0 18.304 0.036 Vel = 1.39 0.0 23.66 59.938 K Factor = 3.06 *NEW PATH 10 -5.68 2.157 0.0 4.500 66.581 to 120.0 0.0 0.0 0.0 21 -5.68 -0.0004 0.0 4.500 -0.002 Val = 0.50 21 2.66 2.157 0.0 10.500 66.579 to 120.0 0.0 0.0 0.0 22 -3.02 -0.0001 0.0 10.500 -0.001 Vel = 0.27 22 0.0 1.442 T 7.432 16.480 66.578 to 120.0 0.0 7.432 0.0 29 -3.02 -0.0008 0.0 23.912 -0.020 Vel = 0.59 29 0.0 1.442 T 7.432 14.230 66.558 to 120.0 0.0 7.432 0.0 30 -3.02 -0.0008 0.0 21.662 -0.018 Vel = 0.59 30 0.0 1.442 E 3.716 241.390 66.540 120.0 T 7.432 11.148 0.0 3 -3.02 -0.0008 0.0 252.538 -0.211 Vel = 0.59 0.0 -3.02 66.329 K Factor= -0.37 Final CIcuIations - Hazen-Williams A&D FIRE SPRINKLERS Page 13 ZIMMER BIOMET (CORRECTION 2) Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn *NEW PATH 7 2.67 1.442 T 7.432 263.090 66.352 to 120.0 E 3.716 11.148 0.0 27 2.67 0.0007 0.0 274.238 0.182 Vel = 0.52 27 0.0 1.442 0.0 15.930 66.534 to 120.0 0.0 0.0 0.0 23 2.67 0.0007 0.0 15.930 0.011 Vel = 0.52 23 0.0 1.442 T 7.432 9.840 66.545 to 120.0 0.0 7.432 0.0 24 2.67 0.0006 0.0 17.272 0.011 Vel = 0.52 24 0.0 1.442 0.0 6.640 66.556 to 120.0 0.0 0.0 0.0 25 2.67 0.0006 0.0 6.640 0.004 Vel = 0.52 25 0.0 1.442 T 7.432 20.290 66.560 to 120.0 0.0 7.432 0.0 21 2.67 0.0007 0.0 27.722 0.019 Vel = 0.52 0.0 2.67 66.579 K Factor= 0.33 tqco Fire Protection Products Worldwide Contaôts I www.tyco-fire.com Series EC-11 and EC-14 Sprinklers, 112 K and 140 K Upright and Pendent Extended Coverage Light and Ordinary Hazard General Description TYCO Series EC-11 and EC-14 Extended Coverage Upright and Pendent Sprinklers are decorative glass-bulb sprinklers designed for use in light or ordinary hazard occu- pancies. They are intended for use in automatic sprinkler systems designed in accordance with standard installa- tion rules (e.g., NFPA 13) for a maximum coverage area of 400 ft2 (37,2 m2), as compared to the maximum coverage area of 130 ft2 (12,1 m2) for standard coverage sprinklers used in ordinary hazard occupancies or 225 ft2 (20,6 m2) for standard coverage sprinklers used in light hazard occupancies. Series EC-11 and EC-14 Sprinklers feature a UL and C-UL Listing that permits their use with unobstructed or non-combustible obstructed ceiling construction as defined and permitted by NFPA 13, as well as a specific appli- cation listing for use under concrete tees. Series EC-11 and EC-14 Extended Coverage Sprinklers have been fire tested to compare their performance to that of standard coverage spray sprin- klers. These tests have shown that the protection provided is equal to or more effective than standard coverage spray sprinklers. IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. Page 1 of 8 Corrosion-resistant coatings, where applicable, help extend the life of copper alloy sprinklers beyond that which occurs when exposed to corrosive atmospheres. Although corro- sion-resistant coated sprinklers passed standard corrosion tests of the appli- cable approval agencies, this testing is not representative of all possible corrosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these corrosion-resistant coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/ chemical velocity should be consid- ered, along with the corrosive nature of the chemical to which the sprinklers will be exposed. NOTICE Series EC-11 and EC-14 Extended Coverage Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating condition. Contact the installing contractor or product manufacturer with any questions. NOVEMBER 2014 Sprinkler Identification Numbers (SINs) TY5137 - Upright, 11.2K TY5237 - Pendent, 11.2K TY6137 - Upright, 14.0K TY6237 - Pendent, 14.0K TV5137 is a re-designation for C5137, G1894, and S2510. TY5237 is a re-designation for C5237, G1893, and S2511. TY6137 is a re-designation for C6137, G1896, and S2610. TY6237 is a re-designation for C6237, G1895, and S2611. TFP22O WRENCH 3/4" FLAT NPT** 2-7/16" (61,9 mm) UPRIGHT & PENDENT 1/2(12,7mm) J NOMINAL MAKE-IN UPRIGHT TFP22O Page 2 of 8 ESCUTCHEON PLATE Components: SEATING SURFACE 1 1 - Frame 2 - Button 3 - Sealing Assembly / 2 4-Bulb 5 - Compression Screw 6 - Deflector* * Temperature rating is II 1-11/16" indicated on Deflector. (42,71mm) J __________ ------ 5 - Pipe thread connections per ISO 7-1 can be provided on special request. 6* CROSS PENDENT SECTION FIGURE 1 SERIES EC-Il AND EC-14 EXTENDED COVERAGE SPRINKLERS 11.2 K-FACTOR UPRIGHT (TY5137) AND PENDENT (TY5237) 14.0 K-FACTOR UPRIGHT (f6137) AND PENDENT (7Y6237) ASSEMBLY Technical Data Approvals TYCO Series EC-11 and EC-14 Extended Coverage Upright, Pendent, and Recessed Pendent Sprinklers are UL and C-UL Listed. Refer to Table A for complete sprinkler approval infor- mation including corrosion-resistant status. The approvals apply to the service conditions indicated in the Design Criteria section. Series EC-11 and EC-14 Extended Coverage Upright and Pendent Sprinklers are FM Approved. Refer to Table A for complete sprinkler approval information including corrosion-resis- tant status. The approvals apply to the service conditions indicated in the Design Criteria section. The Style 60 Two-Piece Flush Escutcheon (Figure 4) is UL Listed and FM Approved for use with the Series EC-11 and EC-14 Pendent Sprinklers. Maximum Working Pressure 175 psi (12,1 bar) Pipe Thread Connection 3/4 inch NPT Discharge Coefficients K = 11.2 gpm/ps11/2 (161,3 1pm/bar"2) K = 14.0 gpm/p5i112 (201,6 1pm/barll2) Temperature Ratings Refer to Table A. Finish Sprinkler: Refer to Table A. Recessed or Flush Escutcheon: White-Coated, Chrome-Plated, and Brass-Plated Physical Characteristics Frame.......................Bronze Button.......................Bronze Sealing Assembly.......Beryllium Nickel w/TEFLON Bulb ...................Glass (3 mm) Compression Screw............Bronze Deflector......................Brass Operation The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, which then allows the sprinkler to activate and flow water. Design Criteria TYCO Series EC-11 and EC-14 Extended Coverage Sprinklers must only be installed in accordance with the applicable UL and C-UL Listing or FM Approval requirements as indicated below. Only Style 30 or 40 Recessed Escutcheons are to be used for recessed installation, as applicable. Refer to Tables A, B, and C. TFP22O Page 3 of 8 Hazard Type Temperature Bulb Liquid Sprinkler Finish (See Note 5) Natural Brass I Chrome Plated Polyester* Lead Coated Upright K=11.2 (TY5137) 135°F (57°C) Orange 1,2,3",4 155°F (68°C) Red 175°F (79°C) Yellow Light Pendent Table B describes UL and C-UL K11.2 (TY5237) K=14.0 (TY6237) 1,2,4 1,2,4 200°F (93°C) Green 286°F (141°C) Blue Recessed Pendent K=11.2 (TY5237) K=14.0 (TY6237) With Style 30 Escutcheon 135°F (57°C) Orange 1,2,3,4 1, 2, 4 N/A Sensitivity Rating Table C describes FM Sensitivity Rating 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue Ordinary Table B describes UL and C-UL Sensitivity Rating Table C describes FM Sensitivity Rating Upright K11.2 (TY5137) K=14.0 (-rv6I37) Pendent K=11.2 (TY5237) K14.0 (TY6237) 135°F (57°C) Orange 1, 2, 3, 4 286°F (141°C) 1, 2, 3, 4 155°F (68°C) Red 175°F (79°C) Yellow 1, 2, 4 200°F (93°C) Green K11.2 (TY5237) K=14.0 (TY6237) With Style 30 or 40 Recessed Pendent 135°F (57°C) Orange 1, 2, 4 N/A 155°F (68°C) Red 175°F (79°C) Yellow Escutcheon 200°F (93°C) Green Notes (5). Where Polyester Coated or Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Cor- Listed by Underwriters Laboratories, Inc. (UL) rosion Resistant Sprinklers Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) * Frame and Deflector only. Approved by Factory Mutual Research Corporation (FM) ** Pendent Only Approved by the City of New York under MEA 17703E N/A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS Light Hazard Ordinary Hazard Area Style 135°F 155°F 175°F 200°F 286°F 135°F 155°F 175°F 200°F 286°F (57°C) (68°C) (79°C) (93°C) (141°C) (57°C) (68°C) (79°C) (93°C) (141°C) Upright or Pendent - - - - - OR OR OR OR OR 14 x 14 Style 30 Recessed - - - - - OR OR OR OR OR Style 40 Recessed - - - - - OR OR OR OR OR Upright or Pendent QR* QR* QR* QR* QR* SR SR SR SR SR 16 x 16 Style 30 Recessed QR* QR* OR* QR* QR* SR SR SR SR SR Style 40 Recessed N/A N/A N/A N/A N/A SR SR SR SR SR Upright or Pendent OR* OR* OR* QR* QR* SR SR SR SR SR 18 x 18 Style 30 Recessed OR* OR* QR* QR* OR* SR SR SR SR SR Style 40 Recessed N/A N/A N/A N/A N/A SR SR SR SR SR Upright or Pendent QR* QR* QR* SR SR* SR SR SR SR SR 20 x 20 Style 30 Recessed OR* QR* OR* SR* SR* SR SR SR SR SR Style 40 Recessed N/A N/A N/A N/A N/A SR SR SR SR SR OR: Quick Response SR: Standard Response N/A: Not Applicable * Does not apply to Upright K=14.0 TABLE B SENSITIVITY RATING FOR (IL AND C-UL LISTING OF SERIES EC-1 1 OR EC-14 SPRINKLERS (Refer to Table D for Permitted K-Factor/Area Combinations) TFP22O Page 4 of 8 HC-1 Linear Spacing Area Spacing Ceiling Height Ceiling Type K-factor Style Response Min Max Min Max Noncombustible Unobstructed, 11.2 EC Pendent or 10 20 100 400 Upto30 Noncombustible Obstructed, or 14.0 EC Upright Combustible Unobstructed Noncombustible Unobstructed, 11.2 EC Pendent 10 20 100 400 Up to 30 Noncombustible Obstructed, or 14.0 EC Recessed Combustible Unobstructed Style 30 10 20 100 400 Up to 30 Combustible obstructed 11.2 EC EC Pendent or Upright Quick 14.0 11.2 EC Pendent 10 20 100 400 Up to 30 Combustible obstructed 14.0 EC Recessed Style 30 10 20 100 400 Over 30 and up to 45 Noncombustible Unobstructed 11.2 EC 14.0 EC Upright HC-2 Linear Spacing Area Spacing Ceiling Height Ceiling Type K-f actor Style Response Min Max Min Max 10 20 100 400 Up to 30 11.2 EC Upright 10 20 100 400 Up to 30 14.0 EC Pendent or Upright Noncombustible Unobstructed, Quick Combustible Unobstructed 10 16 100 256 Over 30and up to 45 __________ 11.2 EC 14.0 EC Upright HC-3 Linear Spacing Area Spacing Ceiling Height Ceiling Type K-Factor Style Response Min Max Min Max 10 16 100 256 Up to 30 Noncombustible Unobstructed, 11.2 EC Upright Quick 10 20 100 400 Up to 30 14.0 EC Pendent or Upright Combustible Unobstructed 10 16 100 256 Over 30and up to 45 __________ 11.2 EC, 14.OEC __________ Upright NOTE The design for K 11.2 EC (K 160 EC) sprinklers should not include fewer than six sprinklers or have a design pressure of less than 12 psi (0,8 bar); similarly the design for K 14.0 EC (K 200 EC)sprinklers should not include fewer than four sprinklers or have a design pressure of less than 18 psi (1,2 bar). For flow criteria, refer to FM Loss Prevention Data Sheet 3-26. TABLE C SENSITIVITY RATING FOR FM APPROVAL OF SERIES EC-1 I OR EC-I4 SPRINKLERS (Note: Refer to FM Loss Prevention Data Sheet 2-0 for permitted K-factor/area combinations) UL and C-UL Listing Requirements Series EC-11 and EC-14 Sprinklers may be used for the coverage areas shown in Table D, based on main- taining the minimum specified flow rate as a function of coverage area and hazard group for all sprinklers in the design area. Series EC-11 and EC-14 Sprinklers are permitted to be used with unobstructed or non-combustible obstructed ceiling construction as defined and permitted by NFPA 13; for example: Unobstructed, combustible or noncombustible, ceiling construc- tion with a deflector to ceiling/roof deck distance of 1 to 12 inches (25 to 300 mm). Obstructed, non-combustible, ceiling construction with a deflector location below struc- tural members of 1 to 6 inches (25 to 150 mm) and a maximum deflector to ceiling/roof deck distance of 22 inches (550 mm). Series EC-11 and EC-14 Sprinklers, specifically tested and listed for non-combustible obstructed construction, are permitted to be used within trusses or bar joists having non-combustible web members greater than 1 inch (25.4 mm) when applying the 4 times obstruction criteria rule defined under "Obstructions to Sprinkler Discharge Pattern Development". To prevent cold soldering, the minimum allowable spacing between Series EC-11 and EC-14 Sprinklers, is 8 feet (2,4 m) for upright sprinklers and 9 feet (2,7 m) for pendent sprinklers. TFP22O Page 5 of 8 Description Area Light Hazard 0.10 gpmlft2 Group I Ordinary Hazard 0.15 gpm/ft2 Group II Ordinary Hazard 0.20 gpmlft2 gpm psi gpm psi gpm psi 14 x 14 30 7.2 30 7.2 39 12.1 16x16 30 7.2 39 12.1 51 20.7 TY5137 (K=11.2) Upright 18 x 18 33 8.7 49 19.1 65 33.7 20 x 20 40 12.8 60 28.7 80 51.0 14 x 14 30 7.2 30 7.2 39 12.1 16x16 30 7.2 39 12.1 51 20.7 TY5237 (K=11.2) Pendent 18x18 33 8.7 49 19.1 65 33.7 20 x 20 40 12.8 60 28.7 80 51.0 14 x 14 N/A N/A 39 7.8 51 13.3 1Y6137 16x16 N/A N/A 39 7.8 51 13.3 (K=14.0) Upright 18x18 N/A N/A 49 12.3 65 21.6 20 x 20 N/A N/A 60 18.4 80 32.7 14 x 14 37 7.0 39 7.8 51 13.3 16 x 16 37 7.0 39 7.8 51 13.3 TY6237 (K=14.0) Pendent 18x18 37 7.0 49 12.3 65 21.6 20 x 20 40 8.2 60 18.4 80 32.7 1 ft. = 0.3048 m 1 ft 2 =0.093 m2 1 psi = 0.06895 bar 1 gpm = 3.785 1pm 1 gpm/ft2 = 40.74 mm/mm TABLE D FLOW CRITERIA FOR UL AND C-UL LISTING OF SERIES EC- 11 AND EC-14 SPRINKLERS 5. Series EC-11 and EC-14 Sprinklers are to be installed in accordance with all other requirements of NFPA 13 for extended coverage upright and pendent sprinklers; For example, obstructions to sprinkler discharge, obstructions to sprinkler pattern development, obstructions to prevent sprinkler discharge from reaching hazard and clearance to storage. UL and C-UL Specific Application Listing Requirements for Installation under Concrete Tees Series EC-11 and EC-14 Extended Coverage Upright and Pendent Sprinklers (TY5137, TY5237, TY6137 and TY6237) have a UL and C-UL Specific Application Listing for use under concrete tees when installed as follows: 30 inches (762 mm). The maximum permitted concrete tee length is 32 feet (9,8 m). However, where the concrete tee length exceeds 32 feet (9,8 m), non-combustible baffles, equal in height to the depth of the tees, can be installed so that the space between the tees does not exceed 32 feet (9,8 m) in length. The sprinkler deflectors are to be located in a horizontal plane at or above 1 inch (25,4 mm) below the bottom of the concrete tee stems. When the sprinkler deflectors are located higher than a horizontal plane 1 inch (25,4 mm) beneath the bottom of the concrete tee stems, the obstruction to sprinkler discharge criteria requirements of NFPA 13 for extended coverage upright and pendent sprinklers applies. Factory Mutual Loss Prevention Data Sheet for limited use in buildings of specific roof construction and for the protection of certain specific ordinary hazard (non-storage and/or non-flam- mable or combustible liquid) occu- pancies. Information provided in the FM Loss Prevention Data Sheets relates to, but not limited to, hydraulic design, ceiling slope, and obstructions, minimum and maximum allowable spacing, and deflector-to-ceiling distance. These criteria may differ from UL and/or NFPA criteria. Therefore, the designer should review and become familiar with Factory Mutual requirements before proceeding with design. 1. Stems of the concrete tee construc- FM Approval Requirements tion must spaced at less than 7.5 Series EC-11 and EC-14 Extended feet (2,3 m) on center but more than Coverage Sprinklers are to be installed 3 feet (0,9 m) on center. The depth of in accordance with the applicable the concrete tees must not exceed TFP22O Page 6 of 8 2-7/8° DIA. 1/2±1/8 (73,0 mm) 1/2°(12,7mm) (12,7±3,2 mm) 2-1/4 DIA. 1/4 (6,4 mm) FACE OF (57,2 mm) SPRINKLER L.- ...) 1/8° FITTING ). ..( (3,2 mm) MOUNTING MOUNTING SU FACE PLATE CLOSURE 1-3/8° (34,9 mm) 1-1/8" (28,6 mm) FIGURE 2 SERIES EC-11 AND EC-14 RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 2-7/8" DIA. 5/8±1/4" (73,0 mm) 3/4" (19,1 mm) (15,9±6,4 mm) - 2-1/4" DIA. 1/4(6,4 mm) I FACE OF (57,2 mm) SPRINKLER 1/8 FITTING (3,2 mm) L ___ _ I MOUNTING I!ESIR PLATE 1JMOUNTING / SURFACE / - CLOSURE 8'I4,9 m 7/8" (22,2 mm) FIGURE 3 SERIES EC-11 AND EC-14 RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON FACE OF SPRINKLER FITTING: 3/8" (9,5 mm) ABOVE TO 1/8° (3,2 mm) BELOW MOUNTING SURFACE ESCUTCHEON PLATE SEATING SURFACE: 1/4(6,4 mm) ABOVE TO 1/2" (12,7 mm) BELOW MOUNTING SURFACE; 3/4" (19,1 mm) TOTAL ADJUSTMENT Installation Series EC-11 and EC-14 Sprinklers must be installed in accordance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) to 3/32 inch (2,4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 3/4 inch NPT sprinkler joint should be obtained by applying INTERNAL DIMENSIONS OF STYLE 60 ESCUTCHEON ACCOMMODATE CLASS 150 MALLEABLE IRON REDUCING SPRINKLER FITTING a minimum-to-maximum torque of 10 to 20 ft.-lbs. (13,4 to 26,8 Nm). Higher levels of torque may distort the sprinkler inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in an Escutcheon Plate by under or over- tightening the Sprinkler. Re-adjust the position of the sprinkler fitting to suit. Step 1. Install the sprinkler with the deflector parallel to the mounting surface. Install pendent sprinklers in the pendent position; install upright sprin- klers in the upright position. Step 2. After installing the Style 30, 40, or 60 mounting plate (or other FITTING SIDE" TOWARDS SPRINKLER FITtING n (EN WRENCH / D"A") FIGURE 5 W- TYPE 3 SPRINKLER WRENCH WRENCH RECESS - Jo0 ,-- L: LJL WRENCH HEX FIGURE 6 W-TYPE 22 RECESSED SPRINKLER WRENCH applicable escutcheon) over the sprinkler pipe threads and with pipe- thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step 3. For upright or pendent sprin- klers wrench-tighten using only the - 2-7/8" DIA. (73,0 mm) 2-1/4° DIA. (57,2 mm) J J, MOUNTING 1/8" SURFACE (3,2 mm) / CLOSURE 3/4° NPT 2-5/16" (58,7 mm) -MOUNTING 1-13/16" (46,0 mm) PLATE 11 FIGURE 4 SERIES EC-1 I AND EC-14 PENDENT SPRINKLER ASSEMBLY WITH 314 INCH TOTAL ADJUSTMENT STYLE 60 TWO-PIECE FLUSH ESCUTCHEON TFP22O Page 7 of 8 P/N 51 - XXX - X - XXX I_ SIN j__ SPRINKLER TEMPERATURE I_ FINISH* RATING 893 11.2K PENDENT TY5237 1 NATURAL BRASS 135 135°F(57°C) 894 11.2K UPRIGHT TY5137 4 SIGNAL WHITE (RAL9003) POLYESTER 155 155°F (68°C) 895 14.0K PENDENT TY6237 5 JET BLACK (RAL9005) POLYESTER 175 175°F (79°C) 896 14.0K UPRIGHT TY6137 7 LEAD COATED 200 200°F (93°C) Escutcheon ordered separately 9 CHROME-PLATED 286 286°F (141°C) 000 OPEN** ** OPEN indicates sprinkler assembly without glass bulb, button, and sealing assembly. TABLE E SERIES EC-11 AND EC-14 UPRIGHTAND PENDENT SPRINKLERS PART NUMBER SELECTION W-Type 3 (End A) Sprinkler Wrench. For the pendent sprinkler installed with Style 30, 40, or 60 Escutcheon, wrench-tighten the sprinkler using only the W-Type 22 Sprinkler Wrench. Apply the wrench recess of the appli- cable sprinkler wrench (Figure 5 and 6) to the sprinkler wrench flats (Figure 1). Care and Maintenance TYCO Series EC-11 and EC-14 Sprinklers must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/slippage, or. the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) Frequent visual inspections are recom- mended to be initially performed for corrosion resistant coated sprin- klers, after the installation has been completed, to verify the integrity of the corrosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of inspecting from the floor level, a random sampling of close-up visual inspections should be made, so as to better determine the exact sprinkler condition and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards recognized by the Approval agency (e.g., NFPA 25), in addition to the standards of any authorities having jurisdiction. Contact the installing contractor or product manufacturer with any questions. Automatic sprinkler systems are recom- mended to be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series EC-il or EC-14 (specify) Sprinkler, SIN (specify), (specify) K-factor, Pendent or Upright (specify) Extended Coverage, (specify) temper- ature rating, (specify) finish, P/N (from to Table E) Recessed Escutcheon, Two-Piece Specify: Style (30 or 40) Two-Piece Recessed Escutcheon with (specify) finish, P/N (specify*) Flush Escutcheon, Two-Piece Specify: Style 60 Two-Piece Flush Escutcheon with (specify) finish, P/N (specify*) *Refer to Technical Data Sheet TFP778 Sprinkler Wrenches Specify: W-Type 3 Sprinkler Wrench, P/N 56-895-1-001 Specify: W-Type 22 Recessed Sprinkler Wrench, P/N 56-665-7-001 TFP22O Page 8 of 8 UARTERS 11400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700 Dducts, LP. All rights reserved. flnrnnrtinn tqca