Loading...
HomeMy WebLinkAbout1525 FARADAY AVE; ; AS0500069/12/23, 2:30 PM AS050006 Permit Data City of Carlsbad Sprinkler Permit Job Address: 1525 FARADAY AV Permit Type: SPRINK Parcel No: Lot #: 0 Reference No.: Permit No: AS050006 Status: ISSUED Applied 1/26/2005 Approved: 1/31/2005 Issued: 1/31/2005 PC #: Inspector: Project Title: GATZKE, DILLION, SUITE 120 T.I. FIRE SPRINKLER PLAN CHECK & INSPECTIONS Applicant: COSCO FIRE PROTECTION STEIO5 10695 TREENA ST SAN DIEGO, CA 858-444-2000 Owner: Fees ($) Add'I Fees ($) Total ($) Balance ($) 115 0, 115 0 about:blank 1/1 Reliable Model F1FR Sprinkler Types Standard Upright Standard Pendent Conventional Vertical Sidewall Horizontal Sidewall - HSW 1 Deflector Model Fl FR Recessed Sprinkler Types Recessed Pendent Recessed Horizontal Sidewall - HSW 1 Deflector Listings & Approvals Listed by Underwriters Laboratories, Inc. (UL) Listed by Underwriters' Laboratories of Canada (ULC) Certified by FM Approvals Loss Prevention Council (LPC, UK) NYC BS&A No. 587-75-SA Meets MIL-S-901C and MIL-STD 167-1 Verband der Schadenversicherer (VdS, Germany) NYC MEA 258-93-E UL Listing Category Sprinklers, Automatic & Open Quick Response Sprinkler A'C'500'KaBulletin 136 Rev.L Model Fl FR Model Fl FR Recessed Quick Response Sprinklers :- - •iI Upright Pendent Vertical Sidewall Conventional UL Guide Number VNIV Product Description Reliable Models F1FR and F1FR Recessed Sprinklers are quick response sprinklers which combine the durability of a standard sprinkler with the attractive biv profile of a decorative sprinkler. The Models Fl FR and Fl FR Recessed automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrated response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model Fl FR and Fl FR Recessed sprinklers to apply water to a fire much faster than standard sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely manufac- tured glass capsule. This glass bulb is specially constructed to provide fast thermal response. The balance of parts are made of brass, copper and beryllium nickel. At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid ex- pands, forcing the bubble smaller and smaller as the liquid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. The temperature rating of the sprinkler is identified by the color of the glass bulb. Recessed Pendent Application Quick response sprinklers are used in fixed fire protec- tion systems: Wet, Dry, Deluge or Preaction. Care must be exercised that the orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of the National Fire Protection Asso- ciation or the approving Authority Having Jurisdiction. Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and stan-dard response sprinklers should not be intermixed. Horizontal Sidewall HSW 1 Deflector The Reliable Automatic Spdnkler Co., Inc.525 North MacQuesten Parlay, Mount Vernon, New York 10552 Model Fl FR Quick Response Upright, Pendent & Conventional Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Sprinkler Type Standard-Upright (SSU) and Pendent (SSP) Deflectors Marked to Indicate Position K Factor Sprinkler Height Approval Organization Sprinkler Identification Number (SIN) US Metric SSU SSP )ç' (15mm) Standard Orifice with )" NPT (RXJ Thread 5.6 80 2.2" (56mm) 1,2,34,5,6,7 R3625 R3615 %" (20mm) Large Orifice with 3" NPT (R ea 8.0 115 2.3" (58mm) 1,2,3,4,7,8 R3622 R3612 7/ (17mm) Small Orifice with )" NPT (RX) Thread 4.2 60 2.54" (65mm) 1,2,8 R3623 R3613 %" (l0mm)SmallOrificewithX"NPT(RX)Thread 2.8 40 2.54"(65nm) 1,2,8 R3621 R3611 lomm Orifice XLH with We" Thread 4.2 60 56.1mm 4,6,7 R3624 R3614 Conventional-Install in Upright or Pendent Position 4.2 5.6 8.0 60 80 115 56.1mm 56.1mm 1 58.4mm - 4,6,7 1 4,7 R3674 R3675 1 R3672 10mm Orifice XLH with R%Thread 15mm Standard Orifice with X" NPT (RX) Thread 20mm Large Orifice with 3/4"NPT(R3A)Thread Upright Pendent Upright Conventional Model Fl FR Quick Response Recessed Pendent Sprinkler Installation Wrench: Model RC1 Sprinkler Wrench Installation Data: Nominal Orifice Thread Size K Factor Sprinkler Height Approval(') Organizations Sprinkler identification Number (SIN) US Metric )" (15mm) X"NPT(R½) 5.6 80 2.2' (56mm) 1,2,3,4,5,7,8 R3615 %"(20rnm) Y4"NPTR3A 8.0 115 2.3"58mm) 1,2.3 R3612 " (11mm) X" NPT (RY2) 1 4.2 60 2.54"(65mm) 12.8 R3613 K (lam) X" NPT (R½) 2.8 40 2.54"(65nm) 12,8 R3611 10mm W. 4.2 60 56.1mm 4,7 R3614 (1) Refer to escutcheon data table for approvals and dimensions. 2. Model Fl FR Quick Response Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy Installation Data: Nominal Orifice Thread Size K Factor Sprinkler Height Approval Organizations Sprinkler Identification Number (SIN) US Metric 1/2 1/2 NPT (R½) 5.6 80 2.2" (56mm) 1,2,3.6,8 R3685 15mm ½" NPT (R1/2) 5.6 80 2.2" (56mm) 4(1) (') LPC Approval is for Pendent position only. I Deflector to Ceiling I Orientation I Dimension (Mm. - Max.) I Upright I 4" - 12" (102mm - 305mm) I Pendent I 6"- 12" (152mm - 305mm) Vertical Sidewall Model Fl FR Quick Response Horizontal Sidewall Sprinkler Deflector: HSW 1 Installation Wrench: Model D Sprinkler Wrench Installation Data: K Factor Approval Organizations and Type of Approval Sprinkler identification Nominal Orifice Thread Size US I I Metric Sprinkler Length Light Hazard I Ordinary Hazard Number (SIN) )" (15mm) )" NPT(R36) 5.6 80 2.63" (67mm) 1,2,3.5,8 1,2,5,8 R3635 NOTE: UL and ULC Listing permits use with Fl or F2 recessed escutcheon. horizontal biciewaii 3. Installation Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and standard response sprinklers should not be intermixed. The Model F1FR Recessed Quick Response Sprinklers are to be installed as shown. The Model Fl or F2 Escutch- eons illustrated are the only recessed escutcheons to be used with the Model Fl FR Sprinklers. The use of any other recessed escutcheon will void all approvals and negate all warranties. When installing Model Fl FR Sprinklers, use the Model D Sprinkler Wrench. When installing Model Fl FR Recessed Sidewall Sprinklers, use the Model GFR1 Sprinkler Wrench. Use the Model AOl Wrench for installing F1FR Recessed Pendent Sprinklers. Any other type of wrench may damage these sprinklers. Temperature Ratings Classification Sprinkler Temmmture MaL Ambient Temp. Bulb Color °C _E_ Ordinary 57 135 100°F(38°) Orange Ordinary 68 155 100°F(38°c) Red Intermediate 79 175 150F(66°c) Yellow Intermediate 93 200 150°F(66C) Green High (1) 141 286 225°F(107°c) Blue (1) Not available for recessed sprinklers. Escutcheon Data Escutcheon Feceof Fitting Model MInenslon to ngor Fl 1,2.4 wali Dimension 3(6 _X6 (19mm) ____ r25mm (5rm,-24mm) 1,2,3,4,5,7,8 3(6 -'X6F2 (13mm) (5nm-17mm) F1' 1,2 RillyRecessed 11mm) 12 Fully Retracted 15/N 16 Push-aV Thread-off (24mm) Maintenance The Models F1FR and F1FR Recessed Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gen- tle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprin- klers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to mini- mize the potential for damage to sprinklers that would cause improper operation or non-operation. Sprinkler Types Standard Upright Standard Pendent Conventional Sidewall (Vertical, Horizontal HSW1) Recessed Pendent Recessed Horizontal Sidewall HSW1 Finishes (1) (2) Standard Finishes Sprinkler Escutcheon Bronze Brass Chrome Plated chrome Plated (3) White Polyester Coated White Painted (3) Special Application Finishes Sprinkler Escutcheon Bright Brass Bright Brass Black Plated Black Plated Black Paint Black Paint Off White Off White Satin Chrome Satin Chrome Other finishes and colors are available on special order. Consult the factory for details. FM Approvals is limited to bronze and brass, chrome or black plated finishes only. FP Push-on/Thread-off escutcheon Ordering Information Specify: Sprinkler Model Sprinkler Type Orifice Size Deflector Type Temperature Rating Sprinkler Finish Escutcheon Type Escutcheon Finish (where applicable) Note: When Model F1FR Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. The equipment presented in this bulletin is to be installed in accordance with the latest pertinent standards of the National Fire Protection Association. Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputa-ble sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co., Inc. Paw (8 00)431-1588 Sales Sales Offices (800)848-6051 Sates Fax (914)668-3470 Corporate Offices w.rellablespdnkler.com Internet Address Revision lines indicate updated or new data EG. PM.dm USA. 33 Pft1999997X27